76
|
Weisschuh N, Stingl K, Audo I, Biskup S, Bocquet B, Branham K, Burstedt MS, De Baere E, De Vries MJ, Golovleva I, Green A, Heckenlively J, Leroy BP, Meunier I, Traboulsi E, Wissinger B, Kohl S. Mutations in the gene PDE6C encoding the catalytic subunit of the cone photoreceptor phosphodiesterase in patients with achromatopsia. Hum Mutat 2018; 39:1366-1371. [PMID: 30080950 DOI: 10.1002/humu.23606] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2018] [Revised: 07/24/2018] [Accepted: 08/02/2018] [Indexed: 12/22/2022]
Abstract
Biallelic PDE6C mutations are a known cause for rod monochromacy, better known as autosomal recessive achromatopsia (ACHM), and early-onset cone photoreceptor dysfunction. PDE6C encodes the catalytic α'-subunit of the cone photoreceptor phosphodiesterase, thereby constituting an essential part of the phototransduction cascade. Here, we present the results of a study comprising 176 genetically preselected patients who remained unsolved after Sanger sequencing of the most frequent genes accounting for ACHM, and were subsequently screened for exonic and splice site variants in PDE6C applying a targeted next generation sequencing approach. We were able to identify potentially pathogenic biallelic variants in 15 index cases. The mutation spectrum comprises 18 different alleles, 15 of which are novel. Our study significantly contributes to the mutation spectrum of PDE6C and allows for a realistic estimate of the prevalence of PDE6C mutations in ACHM since our entire ACHM cohort comprises 1,074 independent families.
Collapse
|
77
|
Kurtenbach A, Hahn G, Kernstock C, Hipp S, Zobor D, Stingl K, Kohl S, Bonnet C, Mohand-Saïd S, Sliesoraityte I, Sahel JA, Audo I, Fakin A, Hawlina M, Testa F, Simonelli F, Petit C, Zrenner E. Usher Syndrome and Color Vision. Curr Eye Res 2018; 43:1295-1301. [PMID: 30012035 DOI: 10.1080/02713683.2018.1501804] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
Abstract
PURPOSE The aim of this study is to report on the results of color vision testing in a European cohort of patients with Usher syndrome (USH). We describe the results in relation to Usher type (USH1 and USH2), age and visual acuity. METHODS AND METHODS The color vision of 220 genetically confirmed adult USH patients, aged 18-70 years, was analyzed with one of three methods: the Farnsworth D-15 Dichotomous test (D-15) along with the Lanthony desaturated 15 Hue tests (D-15d), the Roth 28-Hue test, or the Ishihara 14-plate test. Visual acuity was measured with either the ETDRS or the SNELLEN charts. The Confusion index, the Selectivity index and the Confusion angle were calculated for the panel tests and used for analysis. The numbers of plates that could not be read were analyzed for the Ishihara test. RESULTS For the panel tests, the degree of color loss (Confusion index) is similar in both subtypes of USH, but the polarization of error scores (Selectivity index) is significantly lower in USH1 than USH2, showing more diffuse errors than those found in USH2. There is no significant correlation between logMAR visual acuity and the Confusion or the Selectivity indices. Additionally, we find a significant correlation between patient age and the degree and the polarity of the loss only in USH2. There was no difference between USH1 and USH2 in the results of the Ishihara test. CONCLUSIONS The examination of color vision in patients with USH shows a significant difference in the pattern of color vision loss in USH1 and USH2 patients, but not in the severity of the loss. In USH2, we find a correlation between patient age and the degree and the polarity of the loss. These results may be due to differences in the pathogenesis of retinal dystrophy in USH1 and USH2.
Collapse
|
78
|
Kuehlewein L, Kitiratschky V, Gosheva M, Edwards TL, MacLaren RE, Groppe M, Kusnyerik A, Soare C, Jackson TL, Sun CH, Chee C, Sachs H, Stingl K, Wilhelm B, Gekeler F, Bartz-Schmidt KU, Zrenner E, Stingl K. Optical Coherence Tomography in Patients With the Subretinal Implant Retina Implant Alpha IMS. Ophthalmic Surg Lasers Imaging Retina 2018; 48:993-999. [PMID: 29253302 DOI: 10.3928/23258160-20171130-06] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2017] [Accepted: 11/01/2017] [Indexed: 11/20/2022]
Abstract
BACKGROUND AND OBJECTIVE The aim of this study was to assess changes in retinal structure and thickness after subretinal implantation of the Retina Implant Alpha IMS (Retina Implant AG, Reutlingen, Germany). PATIENTS AND METHODS Spectral-domain optical coherence tomography (SD-OCT) imaging was performed to assess the structure and thickness of the retina anterior to the microphotodiode array preoperatively, within 6 weeks and 6 months ± 1 month after implantation. Thickness measurements were performed using the distance tool of the built-in software. Three thickness measurements were performed in each of the four quadrants of the retina on the microchip within 6 weeks and 6 months ± 1 month after implantation. RESULTS The mean ± standard deviation change in retinal thickness from within 6 weeks to 6 months ± 1 month after implantation in all four quadrants combined was 24 μm ± 68 μm. None of the tested variables (location, time, or their interaction) had a statistically significant effect on the mean retinal thickness (P = .961, P = .131, and P = .182, respectively; n = 19). CONCLUSION The authors report on qualitative and quantitative findings in retinal structure in 27 patients after subretinal implantation of the Retina Implant Alpha IMS using OCT technology. No significant changes of retinal thickness could be observed in a period of 6 months after surgery. With more patients receiving subretinal implants and with advanced OCT technology, the data set will be extended to study possible changes in retinal structure in finer detail. [Ophthalmic Surg Lasers Imaging Retina. 2017;48:993-999.].
Collapse
|
79
|
Stingl K, Schippert R, Bartz-Schmidt KU, Besch D, Cottriall CL, Edwards TL, Gekeler F, Greppmaier U, Kiel K, Koitschev A, Kühlewein L, MacLaren RE, Ramsden JD, Roider J, Rothermel A, Sachs H, Schröder GS, Tode J, Troelenberg N, Zrenner E. Interim Results of a Multicenter Trial with the New Electronic Subretinal Implant Alpha AMS in 15 Patients Blind from Inherited Retinal Degenerations. Front Neurosci 2017; 11:445. [PMID: 28878616 PMCID: PMC5572402 DOI: 10.3389/fnins.2017.00445] [Citation(s) in RCA: 106] [Impact Index Per Article: 15.1] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2017] [Accepted: 07/20/2017] [Indexed: 11/13/2022] Open
Abstract
Purpose: We assessed the safety and efficacy of a technically advanced subretinal electronic implant, RETINA IMPLANT Alpha AMS, in end stage retinal degeneration in an interim analysis of two ongoing prospective clinical trials. The purpose of this article is to describe the interim functional results (efficacy). Methods: The subretinal visual prosthesis RETINA IMPLANT Alpha AMS (Retina Implant AG, Reutlingen, Germany) was implanted in 15 blind patients with hereditary retinal degenerations at four study sites with a follow-up period of 12 months (www.clinicaltrials.gov NCT01024803 and NCT02720640). Functional outcome measures included (1) screen-based standardized 2- or 4-alternative forced-choice (AFC) tests of light perception, light localization, grating detection (basic grating acuity (BaGA) test), and Landolt C-rings; (2) gray level discrimination; (3) performance during activities of daily living (ADL-table tasks). Results: Implant-mediated light perception was observed in 13/15 patients. During the observation period implant mediated localization of visual targets was possible in 13/15 patients. Correct grating detection was achieved for spatial frequencies of 0.1 cpd (cycles per degree) in 4/15; 0.33 cpd in 3/15; 0.66 cpd in 2/15; 1.0 cpd in 2/15 and 3.3 cpd in 1/15 patients. In two patients visual acuity (VA) assessed with Landolt C- rings was 20/546 and 20/1111. Of 6 possible gray levels on average 4.6 ± 0.8 (mean ± SD, n = 10) were discerned. Improvements (power ON vs. OFF) of ADL table tasks were measured in 13/15 patients. Overall, results were stable during the observation period. Serious adverse events (SAEs) were reported in 4 patients: 2 movements of the implant, readjusted in a second surgery; 4 conjunctival erosion/dehiscence, successfully treated; 1 pain event around the coil, successfully treated; 1 partial reduction of silicone oil tamponade leading to distorted vision (silicon oil successfully refilled). The majority of adverse events (AEs) were transient and mostly of mild to moderate intensity. Conclusions: Psychophysical and subjective data show that RETINA IMPLANT Alpha AMS is reliable, well tolerated and can restore limited visual functions in blind patients with degenerations of the outer retina. Compared with the previous implant Alpha IMS, longevity of the new implant Alpha AMS has been considerably improved. Alpha AMS has meanwhile been certified as a commercially available medical device, reimbursed in Germany by the public health system.
Collapse
|
80
|
Stingl K, Mayer AK, Llavona P, Mulahasanovic L, Rudolph G, Jacobson SG, Zrenner E, Kohl S, Wissinger B, Weisschuh N. CDHR1 mutations in retinal dystrophies. Sci Rep 2017; 7:6992. [PMID: 28765526 PMCID: PMC5539332 DOI: 10.1038/s41598-017-07117-8] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2016] [Accepted: 06/21/2017] [Indexed: 11/13/2022] Open
Abstract
We report ophthalmic and genetic findings in patients with autosomal recessive retinitis pigmentosa (RP), cone-rod dystrophy (CRD) or cone dystrophy (CD) harboring potential pathogenic variants in the CDHR1 gene. Detailed ophthalmic examination was performed in seven sporadic and six familial subjects. Mutation screening was done using a customized next generation sequencing panel targeting 105 genes implicated in inherited retinal disorders. In one family, homozygosity mapping with subsequent candidate gene analysis was performed. Stringent filtering for rare and potentially disease causing variants following a model of autosomal recessive inheritance led to the identification of eleven different CDHR1 variants in nine index cases. All variants were novel at the time of their identification. In silico analyses confirmed their pathogenic potential. Minigene assays were performed for two non-canonical splice site variants and revealed missplicing for the mutant alleles. Mutations in CDHR1 are a rare cause of retinal dystrophy. Our study further expands the mutational spectrum of this gene and the associated clinical presentation.
Collapse
|
81
|
Kovac J, Stessl B, Čadež N, Gruntar I, Cimerman M, Stingl K, Lušicky M, Ocepek M, Wagner M, Smole Možina S. Population structure and attribution of human clinical Campylobacter jejuni isolates from central Europe to livestock and environmental sources. Zoonoses Public Health 2017; 65:51-58. [PMID: 28755449 DOI: 10.1111/zph.12366] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2017] [Indexed: 12/19/2022]
Abstract
Campylobacter jejuni is among the most prevalent causes of human bacterial gastroenteritis worldwide. Domesticated animals and, especially, chicken meat are considered to be the main sources of infections. However, the contribution of surface waters and wildlife in C. jejuni transmission to humans is not well understood. We have evaluated the source attribution potential of a six-gene multiplex PCR (mPCR) method coupled with STRUCTURE analysis on a set of 410 C. jejuni strains isolated from environment, livestock, food and humans in central Europe. Multiplex PCR fingerprints were analysed using Subclade prediction algorithm to classify them into six distinct mPCR clades. A subset of C. jejuni isolates (70%) was characterized by multilocus sequence typing (MLST) demonstrating 74% congruence between mPCR and MLST. The correspondence analysis of mPCR clades and sources of isolation indicated three distinct groups in the studied C. jejuni population-the first one associated with isolates from poultry, the second one with isolates from cattle, and the third one with isolates from the environment. The STRUCTURE analysis attributed 7.2% and 21.7% of human isolates to environmental sources based on MLST and mPCR fingerprints, respectively.
Collapse
|
82
|
Strasser T, Langrova H, Sundermeier S, Hillerkuss D, Stingl K, Durst W, Kurtenbach A, Zrenner E, Zobor D. The Tuebingen Scotopic Threshold Test (TSTT). IEEE J Biomed Health Inform 2017; 22:607-610. [PMID: 28103197 DOI: 10.1109/jbhi.2017.2648891] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Measurement of the dark-adaptation threshold plays a key role in the diagnosis and estimation of disease progression of many retinal disorders. Determining the threshold is, however, difficult to perform in young children. We present here a prototype for a dark adaptometer, the Tuebingen Scotopic Threshold Test aimed to ease measurement of photoreceptor thresholds in young subjects. The device consists of two 7 cm ×10 cm fields with either blue or yellow LEDs, for testing rod or cone sensitivity, respectively. Presentation of homogenous field patterns or a flickering stimulus is also possible. The luminance threshold is measured by the method of ascending limits and the stimulus luminance, data recording and analysis are computer controlled. Preliminary results for six adults and two older children were ascertained and the influence of pupil dilation, binocular presentation, and a flickering stimulus examined. The method provides credible and consistent evaluations of the absolute threshold.
Collapse
|
83
|
Dumic KK, Grubic Z, Yuen T, Wilson RC, Kusec V, Barisic I, Stingl K, Sansovic I, Skrabic V, Dumic M, New MI. Molecular genetic analysis in 93 patients and 193 family members with classical congenital adrenal hyperplasia due to 21-hydroxylase deficiency in Croatia. J Steroid Biochem Mol Biol 2017; 165:51-56. [PMID: 27041116 DOI: 10.1016/j.jsbmb.2016.03.035] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/14/2016] [Revised: 03/15/2016] [Accepted: 03/16/2016] [Indexed: 11/22/2022]
Abstract
Congenital adrenal hyperplasia owing to 21-hydroxylase deficiency is caused by mutation in the CYP21A2 gene. The frequency and spectrum of CYP21A2 mutations and genotype-phenotype correlations among different populations are variable. Aim of this study was to define mutation frequency and spectrum of CYP21A2 gene mutations in patients with classical 21-hydroxylase deficiency (21OHD) and their family members in Croatia and study genotype-phenotype correlation. Clinical features and mutations of CYP21A2 gene in 93 unrelated 21OHD patients and 193 family members were examined. In this cohort, 66 patients were affected with salt wasting (SW) form, and 27 were affected with simple virilizing (SV) form of the disease. Mutations were identified in both alleles (67% compound heterozygous and 33% homozygous) in 91 of 93 patients. Deletions and conversions were found in 18.8% and point mutations in 79.6% alleles. Mutations in 3 alleles (1.6%) remained unidentified (in one patient we found only one, while in other no mutations were found at all). The most common point mutations were Intron 2 splice mutation IVS2-13 A/C>G (35.5%) and p.R357W (16.7%). Genotypes were categorized into Groups 0, A, B and C according to the extent of enzyme impairment. Genotype-phenotype concordance was 100%, 85% and 75% for Groups 0, A and B, respectively. Since only classical 21OHD patients were studied, Group C comprised solely p.P31L mutation and had 73% patients with SV and 27% with SW phenotype. Intrafamilial phenotypic variability was found in two families. CYP21A2 genetic analysis in 193 family members showed that 126 parents were heterozygous carriers, 3 were newly discovered patients, 2 fathers were not biological parents, and mutations were not detected in 3. Among 59 siblings, 32 were heterozygous carriers, 15 carried normal alleles, and 12 were patients (4 newly diagnosed). Genotype-phenotype divergence observed in this study suggests caution in preconceptional counseling and prenatal diagnosis of CAH. High frequency of p.R357W mutation was found in Croatian patients with classical 21-OHD. Genotyping of family members discovered new patients and thus avoided pitfalls in genetic counseling when the parents were found to be affected.
Collapse
|
84
|
Stingl K, Bartz-Schmidt KU, Braun A, Gekeler F, Greppmaier U, Schatz A, Stett A, Strasser T, Kitiratschky V, Zrenner E. Transfer characteristics of subretinal visual implants: corneally recorded implant responses. Doc Ophthalmol 2016; 133:81-90. [PMID: 27510912 PMCID: PMC5052310 DOI: 10.1007/s10633-016-9557-7] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2014] [Accepted: 07/26/2016] [Indexed: 11/30/2022]
Abstract
PURPOSE The subretinal Alpha IMS visual implant is a CE-approved medical device for restoration of visual functions in blind patients with end-stage outer retina degeneration. We present a method to test the function of the implant objectively in vivo using standard electroretinographic equipment and to assess the devices' parameter range for an optimal perception. METHODS Subretinal implant Alpha IMS (Retina Implant AG, Reutlingen, Germany) consists of 1500 photodiode-amplifier-electrode units and is implanted surgically into the subretinal space in blind retinitis pigmentosa patients. The voltages that regulate the amplifiers' sensitivity (V gl) and gain (V bias), related to the perception of contrast and brightness, respectively, are adjusted manually on a handheld power supply device. Corneally recorded implant responses (CRIR) to full-field illumination with long duration flashes in various implant settings for brightness gain (V bias) and amplifiers' sensitivity (V gl) are measured using electroretinographic setup with a Ganzfeld bowl in a protocol of increasing stimulus luminances up to 1000 cd/m2. RESULTS CRIRs are a meaningful tool for assessing the transfer characteristic curves of the electronic implant in vivo monitoring the implants' voltage output as a function of log luminance in a sigmoidal shape. Changing the amplifiers' sensitivity (V gl) shifts the curve left or right along the log luminance axis. Adjustment of the gain (V bias) changes the maximal output. Contrast perception is only possible within the luminance range of the increasing slope of the function. CONCLUSIONS The technical function of subretinal visual implants can be measured objectively using a standard electroretinographic setup. CRIRs help the patient to optimise the perception by adjusting the gain and luminance range of the device and are a useful tool for clinicians to objectively assess the function of subretinal visual implants in vivo.
Collapse
|
85
|
Grobbel J, Dietzsch J, Johnson CA, Vonthein R, Stingl K, Weleber RG, Schiefer U. Normal Values for the Full Visual Field, Corrected for Age- and Reaction Time, Using Semiautomated Kinetic Testing on the Octopus 900 Perimeter. Transl Vis Sci Technol 2016; 5:5. [PMID: 26966641 PMCID: PMC4782826 DOI: 10.1167/tvst.5.2.5] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2015] [Accepted: 03/16/2015] [Indexed: 11/24/2022] Open
Abstract
PURPOSE To determine normal values of the visual field (VF), corrected for age and reaction time (RT) for semiautomated kinetic perimetry (SKP) on the Octopus 900 perimeter, create a model describing the age-dependency of these values, and assess test-retest reliability for each isopter. METHODS Eighty-six eyes of 86 ophthalmologically healthy subjects (age 11-79 years, 34 males, 52 females) underwent full-field kinetic perimetry with the Octopus 900 instrument. Stimulus size, luminance, velocity, meridional angle, subject age, and their interactions, were used to create a smooth multiple regression mathematical model (V/4e, III/4e, I/4e, I/3e, I/2e, I/1e, and I/1a isopters). Fourteen subjects (2 from each of 7 age groups) were evaluated on three separate sessions to assess test-retest reliability of the isopters. Reaction time (RT) was tested by presenting 12 designated RT-vectors between 10° and 20° within the seeing areas for the III/4e isopter (stimulus velocity, 3°/second). Four RT- vectors were presented at the nasal (0° or 180°), superotemporal (45°), and inferior (270°) meridians. RESULTS The model fit was excellent (r2 = 0.94). The test-retest variability was less than 5°, and the median decrease in this deviation attributed to aging, per decade, for all age groups and for all stimulus sizes was 0.8°. No significant learning effect was observed for any age group or isopter. CONCLUSION Age-corrected and RT-corrected normative threshold values for full-field kinetic perimetry can be adequately described by a smooth multiple linear regression mathematical model. TRANSLATIONAL RELEVANCE A description of the entire kinetic VF is useful for assessing a full characterization of VF sensitivity, determining function losses associated with ocular and neurologic diseases, and for providing a more comprehensive analysis of structure-function relationships.
Collapse
|
86
|
Hafed ZM, Stingl K, Bartz-Schmidt KU, Gekeler F, Zrenner E. Oculomotor behavior of blind patients seeing with a subretinal visual implant. Vision Res 2015; 118:119-31. [PMID: 25906684 DOI: 10.1016/j.visres.2015.04.006] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2014] [Revised: 03/31/2015] [Accepted: 04/02/2015] [Indexed: 11/19/2022]
Abstract
Electronic implants are able to restore some visual function in blind patients with hereditary retinal degenerations. Subretinal visual implants, such as the CE-approved Retina Implant Alpha IMS (Retina Implant AG, Reutlingen, Germany), sense light through the eye's optics and subsequently stimulate retinal bipolar cells via ∼1500 independent pixels to project visual signals to the brain. Because these devices are directly implanted beneath the fovea, they potentially harness the full benefit of eye movements to scan scenes and fixate objects. However, so far, the oculomotor behavior of patients using subretinal implants has not been characterized. Here, we tracked eye movements in two blind patients seeing with a subretinal implant, and we compared them to those of three healthy controls. We presented bright geometric shapes on a dark background, and we asked the patients to report seeing them or not. We found that once the patients visually localized the shapes, they fixated well and exhibited classic oculomotor fixational patterns, including the generation of microsaccades and ocular drifts. Further, we found that a reduced frequency of saccades and microsaccades was correlated with loss of visibility. Last, but not least, gaze location corresponded to the location of the stimulus, and shape and size aspects of the viewed stimulus were reflected by the direction and size of saccades. Our results pave the way for future use of eye tracking in subretinal implant patients, not only to understand their oculomotor behavior, but also to design oculomotor training strategies that can help improve their quality of life.
Collapse
|
87
|
Stingl K, Bartz-Schmidt KU, Besch D, Chee CK, Cottriall CL, Gekeler F, Groppe M, Jackson TL, MacLaren RE, Koitschev A, Kusnyerik A, Neffendorf J, Nemeth J, Naeem MAN, Peters T, Ramsden JD, Sachs H, Simpson A, Singh MS, Wilhelm B, Wong D, Zrenner E. Subretinal Visual Implant Alpha IMS--Clinical trial interim report. Vision Res 2015; 111:149-60. [PMID: 25812924 DOI: 10.1016/j.visres.2015.03.001] [Citation(s) in RCA: 224] [Impact Index Per Article: 24.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2014] [Revised: 02/18/2015] [Accepted: 03/02/2015] [Indexed: 11/27/2022]
Abstract
A subretinal visual implant (Alpha IMS, Retina Implant AG, Reutlingen, Germany) was implanted in 29 blind participants with outer retinal degeneration in an international multicenter clinical trial. Primary efficacy endpoints of the study protocol were a significant improvement of activities of daily living and mobility to be assessed by activities of daily living tasks, recognition tasks, mobility, or a combination thereof. Secondary efficacy endpoints were a significant improvement of visual acuity/light perception and/or object recognition (clinicaltrials.gov, NCT01024803). During up to 12 months observation time twenty-one participants (72%) reached the primary endpoints, of which thirteen participants (45%) reported restoration of visual function which they use in daily life. Additionally, detection, localization, and identification of objects were significantly better with the implant power switched on in the first 3 months. Twenty-five participants (86%) reached the secondary endpoints. Measurable grating acuity was up to 3.3 cycles per degree, visual acuities using standardized Landolt C-rings were 20/2000, 20/2000, 20/606 and 20/546. Maximal correct motion perception ranged from 3 to 35 degrees per second. These results show that subretinal implants can restore very-low-vision or low vision in blind (light perception or less) patients with end-stage hereditary retinal degenerations.
Collapse
|
88
|
Kitiratschky VBD, Stingl K, Wilhelm B, Peters T, Besch D, Sachs H, Gekeler F, Bartz-Schmidt KU, Zrenner E. Safety evaluation of "retina implant alpha IMS"--a prospective clinical trial. Graefes Arch Clin Exp Ophthalmol 2014; 253:381-7. [PMID: 25219982 DOI: 10.1007/s00417-014-2797-x] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2013] [Revised: 08/28/2014] [Accepted: 08/29/2014] [Indexed: 12/27/2022] Open
Abstract
BACKGROUND To restore vision in patients with retinitis pigmentosa, several types of electronic devices have been developed to stimulate neurons at different levels along the visual pathway. Subretinal stimulation of the retina with the Retina Implant Alpha IMS (Retina Implant AG, Reutlingen, Germany) has been demonstrated to provide useful vision in daily life. Here we evaluated the safety of this device. METHODS An interventional, prospective, multi-center, single-arm study was conducted in patients with retinitis pigmentosa with the Retina Implant Alpha IMS. The results from the first nine patients of a single center regarding safety of the device are reported. Any untoward medical occurrence related or unrelated to the tested device was documented and evaluated. RESULTS Nine adult subjects were included in the study at the Tübingen site. Seventy-five adverse events occurred in total, and 53 affected the eye and its adnexa. Thirty-one ocular adverse events had a relationship to the implant that was classified as "certain" while 19 had a probable or possible relationship; three had no relationship to the implant. Thirty-nine ocular adverse events resolved without sequelae, two resolved with sequelae, 11 remained unresolved, and in one the status was unknown. The intensity of ocular adverse events was mild in the majority of cases (n = 45), while six were of moderate and two of severe intensity. There was no non-ocular adverse event with certain relationship to the device. One subject lost light perception (without light localization) in her study eye. CONCLUSIONS In conclusion, this prospective study, "Safety and Efficacy of Subretinal Implants for Partial Restoration of Vision in Blind Patients," shows that the Retina Implant Alpha IMS is an option for restoring vision using a subretinal stimulation device with a clinically acceptable safety profile.
Collapse
|
89
|
Doycheva D, Jägle H, Zierhut M, Deuter C, Blumenstock G, Schiefer U, Stingl K, Januschowski K, Voykov B, Stuebiger N. Mycophenolic acid in the treatment of birdshot chorioretinopathy: long-term follow-up. Br J Ophthalmol 2014; 99:87-91. [PMID: 25061107 DOI: 10.1136/bjophthalmol-2014-305535] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
AIM To assess the long-term efficacy and tolerability of both derivatives of mycophenolic acid, mycophenolate mofetil (MMF) and mycophenolate sodium (MPS), in the therapy of patients with birdshot chorioretinopathy (BSCR). METHODS Retrospective analysis of 24 patients (48 eyes) with BSCR, treated with MMF or MPS with a follow-up of at least 1 year. The main outcome measures included control of inflammation, steroid-sparing potential and side effects. Secondary outcome measure was the development of retinal function during the therapy measured by best-corrected visual acuity (BCVA), visual field and/or electroretinography (ERG). RESULTS Twelve patients (50%) were treated with MMF and 12 patients (50%) with MPS. Control of intraocular inflammation, defined as complete lack of clinical and angiographic signs of inflammatory activity, was achieved in 16 of 24 patients (67%). The angiographic signs of activity were significantly reduced during the follow-up (p<0.05). No significant difference was found in the mean BCVA, the visual field and the ERG parameters during the treatment compared with the baseline (p>0.05). In 20 out of 21 patients (95%) who received systemic corticosteroids, the corticosteroids could be tapered to a daily dose of ≤10 mg (rate 0.26/patient-year). Drug-related side effects occurred in 12 patients (50%, rate 0.16/patient-year). In four patients (17%), a therapy switch from MMF to MPS was undertaken due to gastrointestinal discomfort. CONCLUSIONS Derivatives of mycophenolic acid are effective and safe drugs for the treatment of BSCR. In cases with gastrointestinal side effects, a therapy switch from MMF to MPS should be considered.
Collapse
|
90
|
Stingl K, Bartz-Schmidt KU, Gekeler F, Kusnyerik A, Sachs H, Zrenner E. Functional outcome in subretinal electronic implants depends on foveal eccentricity. Invest Ophthalmol Vis Sci 2013; 54:7658-65. [PMID: 24150759 DOI: 10.1167/iovs.13-12835] [Citation(s) in RCA: 59] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
PURPOSE An active microelectronic subretinal implant, developed to replace the photoreceptive function in hereditary degenerations of the outer retina, has been applied in a pilot and clinical study in patients with end-stage retinal degeneration. METHODS The study population comprised 20 blind patients, all of whom lost vision as result of a hereditary retinal disease. An active visual implant was placed surgically within the subretinal space of each patient: subfoveal placement in eight patients (group 1) and parafoveal placement in 12 (group 2). Standardized low-vision tests, including light perception, light localization, movement detection, grating acuity, and visual acuity by Landolt C-rings, were used under masked, randomized implant-OFF and implant-ON conditions. For the chip-mediated vision functional results of both subject groups were compared. RESULTS Three of 20 patients were excluded from analysis because of surgical or technical implant issues. Among patients with nonfoveal placement of the implant, 80% could perceive light, 10% recognized location, and 10% correctly distinguished stripe patterns up to a resolution of 0.33 cycles/degree. No nonfoveal placement patient passed the motion or Landolt C-ring tests. When the implant was placed subfoveally, 100% of patients could perceive light and determine light localization, 75% could resolve motion up to 35°/s, 88% correctly distinguished stripe patterns up to a resolution of 3.3 cycles/degree, and 38% passed a Landolt C-ring test with a decimal visual acuity of up to 20/546 (logMAR 1.43). CONCLUSIONS Subfoveal placement of active subretinal visual implants allows superior measurable outcomes compared to para- or nonfoveal placement locations. (ClinicalTrials.gov numbers, NCT01024803, NCT00515814.).
Collapse
|
91
|
Burek MK, Grubic Z, Stingl K, Zunec R. Distribution of KIR genes in the Croatian population. Hum Immunol 2013; 74:952-6. [DOI: 10.1016/j.humimm.2013.04.028] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2012] [Revised: 01/23/2013] [Accepted: 04/10/2013] [Indexed: 01/07/2023]
|
92
|
Rintelen B, Sautner J, Stingl K, Kalmann N, Leeb B. AB0267 Does the change of questions assessing patient’s global assessment influence composite scores in rheumatoid arthritis? is there also an influence on agreement of the composite scores to a patient outcome measure like the RADAI-5? Ann Rheum Dis 2013. [DOI: 10.1136/annrheumdis-2012-eular.267] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
|
93
|
Stingl K, Bartz-Schmidt KU, Besch D, Braun A, Bruckmann A, Gekeler F, Greppmaier U, Hipp S, Hörtdörfer G, Kernstock C, Koitschev A, Kusnyerik A, Sachs H, Schatz A, Stingl KT, Peters T, Wilhelm B, Zrenner E. Artificial vision with wirelessly powered subretinal electronic implant alpha-IMS. Proc Biol Sci 2013; 280:20130077. [PMID: 23427175 PMCID: PMC3619489 DOI: 10.1098/rspb.2013.0077] [Citation(s) in RCA: 229] [Impact Index Per Article: 20.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022] Open
Abstract
This study aims at substituting the essential functions of photoreceptors in patients who are blind owing to untreatable forms of hereditary retinal degenerations. A microelectronic neuroprosthetic device, powered via transdermal inductive transmission, carrying 1500 independent microphotodiode-amplifier-electrode elements on a 9 mm2 chip, was subretinally implanted in nine blind patients. Light perception (8/9), light localization (7/9), motion detection (5/9, angular speed up to 35 deg s−1), grating acuity measurement (6/9, up to 3.3 cycles per degree) and visual acuity measurement with Landolt C-rings (2/9) up to Snellen visual acuity of 20/546 (corresponding to decimal 0.037 or corresponding to 1.43 logMAR (minimum angle of resolution)) were restored via the subretinal implant. Additionally, the identification, localization and discrimination of objects improved significantly (n = 8; p < 0.05 for each subtest) in repeated tests over a nine-month period. Three subjects were able to read letters spontaneously and one subject was able to read letters after training in an alternative-force choice test. Five subjects reported implant-mediated visual perceptions in daily life within a field of 15° of visual angle. Control tests were performed each time with the implant's power source switched off. These data show that subretinal implants can restore visual functions that are useful for daily life.
Collapse
|
94
|
Stingl K, Gekeler F, Bartz-Schmidt KU, Kögel A, Zrenner E, Gelisken F. Fluorescein Angiographic Findings in Eyes of Patients with a Subretinal Electronic Implant. Curr Eye Res 2013; 38:588-96. [DOI: 10.3109/02713683.2013.767349] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
|
95
|
Stingl K, Zrenner E. Electronic Approaches to Restitute Vision in Patients with Neurodegenerative Diseases of the Retina. Ophthalmic Res 2013; 50:215-20. [DOI: 10.1159/000354424] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2013] [Accepted: 07/15/2013] [Indexed: 11/19/2022]
|
96
|
Calusic M, Grubic Z, Stingl K, Kamenaric MB, Zunec R. Diversity of HLA-B*35 Alleles and Haplotypes among Croatians. Immunol Invest 2012; 41:856-63. [DOI: 10.3109/08820139.2012.703744] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
|
97
|
Stingl K, Bach M, Bartz-Schmidt KU, Braun A, Bruckmann A, Gekeler F, Greppmaier U, Hörtdörfer G, Kusnyerik A, Peters T, Wilhelm B, Wilke R, Zrenner E. Safety and efficacy of subretinal visual implants in humans: methodological aspects. Clin Exp Optom 2012; 96:4-13. [PMID: 23173814 DOI: 10.1111/j.1444-0938.2012.00816.x] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2012] [Revised: 07/24/2012] [Accepted: 08/07/2012] [Indexed: 11/30/2022] Open
Abstract
BACKGROUND Replacing the function of visual pathway neurons by electronic implants is a novel approach presently explored by various groups in basic research and clinical trials. The novelty raises unexplored methodological aspects of clinical trial design that may require adaptation and validation. METHODS We present procedures of efficacy and safety testing for subretinal visual implants in humans, as developed during our pilot trial 2005 to 2009 and multi-centre clinical trial since 2010. RESULTS Planning such a trial requires appropriate inclusion and exclusion criteria. For subretinal electronic visual implants, patients with photoreceptor degeneration are the target patient group, whereas presence of additional diseases affecting clear optic media or the visual pathway must be excluded. Because sham surgery is not possible, a masked study design with implant power ON versus OFF is necessary. Prior to the efficacy testing by psychophysical tests, the implant's technical characteristics have to be controlled via electroretinography (ERG). Moreover the testing methods require adaptation to the particular technology. We recommend standardised tasks first to determine the light perception thresholds, light localisation and movement detection, followed by grating acuity and vision acuity test via Landolt C rings. A laboratory setup for assessing essential activities of daily living is presented. Subjective visual experiences with the implant in a natural environment, as well as questionnaires and psychological counselling are further important aspects. CONCLUSIONS A clinical trial protocol for artificial vision in humans, which leads a patient from blindness to the state of very low vision is a challenge and cannot be defined completely prior to the study. Available tests of visual function may not be sufficiently suited for efficacy testing of artificial vision devices. A protocol based on experience with subretinal visual implants in 22 patients is presented that has been found adequate to monitor safety and efficacy.
Collapse
|
98
|
Grubic Z, Stingl K, Zunec R. Heterogeneity of HLA-DRB1*04 alleles and haplotypes in the Croatian population. ACTA ACUST UNITED AC 2012; 80:219-23. [PMID: 22881058 DOI: 10.1111/j.1399-0039.2012.01917.x] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
Analysis of allele distribution at the HLA-DRB1*04 gene, as one of the frequent ones among Croatians, and their HLA-A-B-DRB1 haplotypes in the Croatian population was performed in this study. Using LABType® SSO and PCR-SSP method, 11 DRB1*04 subtypes were observed, of which DRB1*04:01 was the most frequent (28.0%) followed by DRB1*04:02 (26.3%), DRB1*04:03 (22.3%), and DRB1*04:04 (14.2%). The significant haplotypes (with highest P value) for given DRB1*04 allele were the following combinations: HLA-B*15:01-DRB1*04:01, HLA-B*38:01-DRB1*04:02, HLA-B*35:03-DRB1*04:03, HLA-B*35:03-DRB1*04:08, HLA-B*14:01-DRB1*04:04, and HLA-B*49-DRB1*04:05. Marked differences in the distribution of our most frequent haplotypes of HLA-B-DRB1*04 (HLA-B*38:01-DRB1*04:02 and HLA-B*15:01-DRB1*04:01) were found in comparison to other European populations investigated so far. Additionally, comparison of HLA-A-B-DRB1*04 haplotypes showed that although there are similarities in the haplotype structure between our and other populations, there are also noteworthy differences. In summary, the identification of conserved and unusual DRB1*04 haplotypes in the present study of Croats should have important clinical implications for donor-recipient matching in the hematopoietic stem cell transplantation program, help in the understanding of HLA polymorphisms in different European populations, and also prove to be very useful in the determination of possible susceptibility genes involved in HLA-DRB1*04-associated diseases.
Collapse
|
99
|
Stingl K, Bartz-Schmidt KU, Besch D, Gekeler F, Greppmaier U, Hörtdörfer G, Koitschev A, Peters T, Sachs H, Wilhelm B, Zrenner E. [What can blind patients see in daily life with the subretinal Alpha IMS implant? Current overview from the clinical trial in Tübingen]. Ophthalmologe 2012; 109:136-41. [PMID: 22350550 DOI: 10.1007/s00347-011-2479-6] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
Abstract
The subretinal visual implant is a scientific research approach to restore partial vision in end-stage hereditary retinal diseases by replacing the function of the degenerated photoreceptors by microelectronic chips. In a clinical trial in Tübingen these implants were tested on voluntary blind patients. By using the implants in daily living the patients reported valuable visual information. The subretinal microchip mediates subjectively useful visual information in near as well as in distant vision.
Collapse
|
100
|
Kusnyerik A, Greppmaier U, Wilke R, Gekeler F, Wilhelm B, Sachs HG, Bartz-Schmidt KU, Klose U, Stingl K, Resch MD, Hekmat A, Bruckmann A, Karacs K, Nemeth J, Suveges I, Zrenner E. Positioning of electronic subretinal implants in blind retinitis pigmentosa patients through multimodal assessment of retinal structures. Invest Ophthalmol Vis Sci 2012; 53:3748-55. [PMID: 22562517 DOI: 10.1167/iovs.11-9409] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
PURPOSE To optimize methods for positioning subretinal visual implants, customizing their cable length, guiding them to the predetermined retinal position, and evaluating their performance. METHODS Ten eyes of 10 patients (6 male, 4 female, mean age 46.4 years) were investigated before implantation of a subretinal visual implant. The structural characteristics of the retina as well as the ocular dimensions were determined. Topographic images of the prospective implantation site were subdivided into grids of squares. Each square received a weighted score for suitability. The sum of the scores was calculated, and the region with the highest score was chosen for the implant. In each case, the implant's power supply cable length was calculated by means of magnetic resonance imaging. The planned and achieved positions before and after implantation were compared. RESULTS The mean light sensitivity ratio between the area actually covered by the chip and that of the planned position was 90.8% with an SD of 11.4%. In two cases with almost perfect positioning, the computed ratio was 100%. Measurements showed that to achieve a 95% sensitivity rate the difference between the planned and achieved chip position must be less than 1.7 mm. Preoperative calculations of the intraocular cable length proved accurate in all cases. CONCLUSIONS Preoperative evaluation of retinal structures and eye morphology is useful for guiding a retinal implant to the designated area. It is a meaningful tool for planning and performing retinal chip implantation, and it optimizes personalized implantation. (ClinicalTrials.gov numbers, NCT00515814, NCT01024803.).
Collapse
|