51
|
Akbar M, Brewer JM, Grant MH. Effect of chromium and cobalt ions on primary human lymphocytesin vitro. J Immunotoxicol 2011; 8:140-9. [DOI: 10.3109/1547691x.2011.553845] [Citation(s) in RCA: 69] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023] Open
|
52
|
Hailer NP, Blaheta RA, Dahlstrand H, Stark A. Elevation of circulating HLA DR(+) CD8(+) T-cells and correlation with chromium and cobalt concentrations 6 years after metal-on-metal hip arthroplasty. Acta Orthop 2011; 82:6-12. [PMID: 21189110 PMCID: PMC3229991 DOI: 10.3109/17453674.2010.548028] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023] Open
Abstract
BACKGROUND AND PURPOSE Following metal-on-metal hip arthroplasty (THA), immunological reactions including changes in lymphocyte populations, aseptic loosening, and lymphocytic pseudotumors occur. We hypothesized that changes in lymphocyte subpopulations would be associated with elevated metal ion concentrations. METHODS A randomized trial involving 85 patients matched for age and sex and randomized to receiving metal-on-metal (n = 41) or metal-on-polyethylene total hip arthroplasty (n = 44) was conducted. 36 patients were eligible for follow-up after mean 7 (6-8) years. Concentrations of chromium and cobalt were analyzed by high-resolution inductively coupled plasma mass spectrometry. Leukocyte subpopulations and immunoglobulins in patient blood were measured using standard laboratory methods. RESULTS Patients with a metal-on-metal hip had higher serum concentrations of chromium (1.05 vs. 0.36 μg/L; p < 0.001) and cobalt (0.86 vs. 0.24 μg/L; p < 0.001) than those with metal-on-polyethylene. The percentage of HLA DR(+) CD8(+) T-cells was higher in the metal-on-metal group (10.6 vs. 6.7%; p = 0.03) and correlated positively with chromium and cobalt concentrations in patient blood (Pearson's correlation coefficient: 0.39, p = 0.02; 0.36, p = 0.03, respectively). The percentage of B-cells was lower in the metal-on-metal group (p = 0.01). The two groups were similar with respect to immunoglobulin concentrations and Harris hip scores, and there were no radiographic signs of loosening. INTERPRETATION We conclude that immunological alterations appear to be associated with increased cobalt and chromium concentrations. It is tempting to speculate that HLA DR(+) CD8(+) T-cells are involved in the pathogenesis of allergic reactions, implant loosening, and lymphocytic pseudotumors.
Collapse
Affiliation(s)
- Nils P Hailer
- Department of Orthopedics, Institute of Surgical Sciences, Uppsala University Hospital, Uppsala, Sweden
| | - Roman A Blaheta
- Department of Urology, Goethe University, Frankfurt am Main, Germany
| | - Henrik Dahlstrand
- Department of Molecular Medicine and Surgery, Section of Orthopedics, Karolinska Institute, Karolinska University Hospital, Stockholm, Sweden
| | - André Stark
- Department of Molecular Medicine and Surgery, Section of Orthopedics, Karolinska Institute, Karolinska University Hospital, Stockholm, Sweden
| |
Collapse
|
53
|
Donell ST, Darrah C, Nolan JF, Wimhurst J, Toms A, Barker THW, Case CP, Tucker JK. Early failure of the Ultima metal-on-metal total hip replacement in the presence of normal plain radiographs. ACTA ACUST UNITED AC 2010; 92:1501-8. [PMID: 21037343 DOI: 10.1302/0301-620x.92b11.24504] [Citation(s) in RCA: 67] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
Metal-on-metal total hip replacement has been targeted at younger patients with anticipated long-term survival, but the effect of the production of metal ions is a concern because of their possible toxicity to cells. We have reviewed the results of the use of the Ultima hybrid metal-on-metal total hip replacement, with a cemented polished tapered femoral component with a 28 mm diameter and a cobalt-chrome (CoCr) modular head, articulating with a 28 mm CoCr acetabular bearing surface secured in a titanium alloy uncemented shell. Between 1997 and 2004, 545 patients with 652 affected hips underwent replacement using this system. Up to 31 January 2008, 90 (13.8%) hips in 82 patients had been revised. Pain was the sole reason for revision in 44 hips (48.9%) of which 35 had normal plain radiographs. Peri-prosthetic fractures occurred in 17 hips (18.9%) with early dislocation in three (3.3%) and late dislocation in 16 (17.8%). Infection was found in nine hips (10.0%). At operation, a range of changes was noted including cavities containing cloudy fluid under pressure, necrotic soft tissues with avulsed tendons and denuded osteonecrotic upper femora. Corrosion was frequently observed on the retrieved cemented part of the femoral component. Typically, the peri-operative findings confirmed those found on pre-operative metal artefact reduction sequence MRI and histological examination showed severe necrosis. Metal artefact reduction sequence MRI proved to be useful when investigating these patients with pain in the absence of adverse plain radiological features.
Collapse
Affiliation(s)
- S T Donell
- Department of Trauma & Orthopaedics, Norfolk & Norwich University Hospital, Colney Lane, Colney, Norwich NR4 7UZ, UK.
| | | | | | | | | | | | | | | | | |
Collapse
|
54
|
Seven years of chronological changes of serum chromium levels after Metasul metal-on-metal total hip arthroplasty. J Arthroplasty 2010; 25:1196-200. [PMID: 19879729 DOI: 10.1016/j.arth.2009.08.016] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/06/2009] [Accepted: 08/26/2009] [Indexed: 02/01/2023] Open
Abstract
Although many authors have reported the serum concentrations of metal ions in patients who had metal-on-metal coupling prostheses, most of the studies were not longitudinal, and the follow-up periods were short. We evaluated the longitudinal changes of serum chromium levels in 44 patients who had undergone unilateral metal-on-metal total hip arthroplasty for a minimum of 7 years postoperatively. Although there was a consistent increase in the mean serum chromium level until 3 years after implantation, there was little difference in the levels from years 3 to 7 postoperatively. Although the serum chromium concentration was low throughout postoperative follow-up for 7 years in about 25% of patients, the serum chromium level stayed high or showed gradual elevation in 16.3% of our patients.
Collapse
|
55
|
Smith TO, Nichols R, Donell ST, Hing CB. The clinical and radiological outcomes of hip resurfacing versus total hip arthroplasty: a meta-analysis and systematic review. Acta Orthop 2010; 81:684-95. [PMID: 21067432 PMCID: PMC3216078 DOI: 10.3109/17453674.2010.533933] [Citation(s) in RCA: 40] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023] Open
Abstract
BACKGROUND AND PURPOSE Hip resurfacing (HRS) procedures have gained increasing popularity for younger, higher-demand patients with degenerative hip pathologies. However, with concerns regarding revision rates and possible adverse metal hypersensitivity reactions with metal-on-metal articulations, some authors have questioned the hypothesized superiority of hip resurfacing over total hip arthroplasty (THA). In this meta-analysis, we compared the clinical and radiological outcomes and complication rates of these 2 procedures. METHODS A systematic review was undertaken of all published (Medline, CINAHL, AMED, EMBASE) and unpublished or gray literature research databases up to January 2010. Clinical and radiological outcomes as well as complications of HRS were compared to those of THA using risk ratio, mean difference, and standardized mean difference statistics. Studies were critically appraised using the CASP appraisal tool. RESULTS 46 studies were identified from 1,124 citations. These included 3,799 HRSs and 3,282 THAs. On meta-analysis, functional outcomes for subjects following HRS were better than or the same as for subjects with a THA, but there were statistically significantly greater incidences of heterotopic ossification, aseptic loosening, and revision surgery with HRS compared to THA. The evidence base showed a number of methodological inadequacies such as the limited use of power calculations and poor or absent blinding of both patients and assessors, possibly giving rise to assessor bias. INTERPRETATION On the basis of the current evidence base, HRS may have better functional outcomes than THA, but the increased risks of heterotopic ossification, aseptic loosening, and revision surgery following HRS indicate that THA is superior in terms of implant survival.
Collapse
Affiliation(s)
- Toby O Smith
- Faculty of Health, University of East Anglia, Norwich
| | - Rachel Nichols
- Physiotherapy Department, Dereham Hospital, Norfolk PCT, Norwich
| | - Simon T Donell
- Institute of Orthopaedics, Norfolk and Norwich University Hospital, Norwich
| | - Caroline B Hing
- Department of Trauma and Orthopaedics, St. George's Hospital, London, UK
| |
Collapse
|
56
|
Afolaranmi GA, Henderson C, Grant MH. Effect of chromium and cobalt ions on phase I and phase II enzymatic activities in vitro in freshly isolated rat hepatocytes. Toxicol In Vitro 2010; 25:125-30. [PMID: 20946949 DOI: 10.1016/j.tiv.2010.10.003] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2010] [Revised: 09/15/2010] [Accepted: 10/04/2010] [Indexed: 10/19/2022]
Abstract
The effect of in vitro exposure to the metal ions (chromium (VI) and cobalt (II)) on phase I and phase II enzymatic activities in freshly isolated rat hepatocytes is reported. Concentrations of metal ions used reflect those reported in the livers of cadavers that had worn metal-on-metal hip implants. To assess the effect of exposure to metal ions on enzymatic activities of phase I metabolic reactions the hydroxylations of testosterone were measured, and the phase II reactions measured were glucuronidation and sulfation. No effect was observed in the formation of the testosterone metabolites measured in the presence of either ion, Cr (VI) inhibited both glucuronidation and sulfation of 7-hydroxycoumarin (7-HC) and 1-naphthol, while Co inhibited only the glucuronidation of 7-HC and 1-naphthol. ATP levels were reduced in freshly isolated rat hepatocytes treated with Cr (VI) compared with control hepatocytes with no metal treatment. Cr (VI) probably inhibits the formation of 3'-phosphoadenosine 5'-phosphosulfate (PAPS), the high energy co-factor of sulfation, by reducing the availability of ATP and also by acting as a substrate analog and competing with sulfate for ATP-sulfurylase. High concentrations of these metal ions in the livers of patients with loose or worn metal implants may act synergistically, and have consequences for the metabolism of xenobiotics.
Collapse
Affiliation(s)
- Grace A Afolaranmi
- Bioengineering Unit, University of Strathclyde, Wolfson Centre, Glasgow, United Kingdom
| | | | | |
Collapse
|
57
|
Donaldson JR, Miles J, Sri-Ram K, Poullis C, Muirhead-Allwood S, Skinner J. The relationship between the presence of metallosis and massive infection in metal-on-metal hip replacements. Hip Int 2010; 20:242-7. [PMID: 20544666 DOI: 10.1177/112070001002000216] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 03/12/2010] [Indexed: 02/04/2023]
Abstract
With the increased use of metal-on-metal as a bearing surface, complications and side effects are being recognised more frequently. We present a small series of a previously unreported complication, which appears specific to metal-on-metal bearing surface arthroplasties: three cases of infection in the presence of local metal debris and histological features of aseptic lymphocytic vasculitis associated lesions (ALVAL). Each case is associated with significant soft tissue loss and bone destruction to such an extent that pelvic discontinuity has occurred. We postulate that the combination of metal debris, ALVAL and tissue necrosis provides a unique environment for peri-prosthetic bacterial growth and rapid spread of infection.
Collapse
Affiliation(s)
- James R Donaldson
- Joint Reconstruction Unit, Royal National Orthopaedic Hospital, Stanmore, UK.
| | | | | | | | | | | |
Collapse
|
58
|
Hosman AH, van der Mei HC, Bulstra SK, Busscher HJ, Neut D. Effects of metal-on-metal wear on the host immune system and infection in hip arthroplasty. Acta Orthop 2010; 81:526-34. [PMID: 20860450 PMCID: PMC3214739 DOI: 10.3109/17453674.2010.519169] [Citation(s) in RCA: 44] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023] Open
Abstract
BACKGROUND AND PURPOSE Joint replacement with metal-on-metal (MOM) bearings have gained popularity in the last decades in young and active patients. However, the possible effects of MOM wear debris and its corrosion products are still the subject of debate. Alongside the potential disadvantages such as toxicity, the influences of metal particles and metal ions on infection risk are unclear. METHODS We reviewed the available literature on the influence of degradation products of MOM bearings in total hip arthroplasties on infection risk. RESULTS Wear products were found to influence the risk of infection by hampering the immune system, by inhibiting or accelerating bacterial growth, and by a possible antibiotic resistance and heavy metal co-selection mechanism. INTERPRETATION Whether or not the combined effects of MOM wear products make MOM bearings less or more prone to infection requires investigation in the near future.
Collapse
Affiliation(s)
| | | | - Sjoerd K Bulstra
- Department of Orthopaedic Surgery, University Medical Center Groningen, Groningen, the Netherlands
| | | | | |
Collapse
|
59
|
Rawal JS, Soler JA, Rhee JS, Dobson MH, Konan S, Haddad FS. Modification of the explant system for the removal of well fixed hip resurfacing sockets. J Arthroplasty 2010; 25:1170.e7-9. [PMID: 20171047 DOI: 10.1016/j.arth.2009.11.003] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/15/2008] [Revised: 10/07/2009] [Accepted: 11/04/2009] [Indexed: 02/01/2023] Open
Abstract
A major concern during revision hip arthroplasty is acetabular bone loss during the extraction of well-fixed acetabular components. Despite the good early survivorship of resurfacing prostheses, revision surgery may be necessary. We recommend the use of the Explant acetabular extraction system (Zimmer, Warsaw, Ind) with a trial liner to preserve acetabular bone stock. We present 2 cases of revised resurfacings using this technique, demonstrating minimal interference to the remaining acetabular bone.
Collapse
Affiliation(s)
- Jaikirty S Rawal
- Department of Trauma and Orthopedics, University College London Hospital, London, United Kingdom
| | | | | | | | | | | |
Collapse
|
60
|
Abstract
Prolongation of the average life expectancy and an active lifestyle in old age are related to the constant increase in the number of joint diseases that eventually require a surgical procedure. The diseased joint is replaced with a joint prosthesis, the functionality of the joint is recovered, and pain is reduced. In the last decade, the number of joint replacement operations has increased several times over and is expected to increase further. In order to enable patients to have a painless and active lifestyle, it is necessary to develop materials that are long-lasting in vivo. Metallic biomaterials must exhibit high corrosion and wear resistance. In vitro research on materials under simulated physiological conditions is presented. These experiments are complemented by examples from clinical practice performed in collaboration with orthopedic surgeons. Morphological and chemical changes in the material during the course of in vivo performance are related to processes of wear and corrosion. The local and systemic consequences of these processes in the human body are presented.
Collapse
Affiliation(s)
- Ingrid Milošev
- 1Jožef Stefan Institute, Jamova c. 39, 1000 Ljubljana, Slovenia and Valdoltra Orthopaedic Hospital, Jadranska c. 31, 6280 Ankaran, Slovenia
| |
Collapse
|
61
|
Kwon YM, Thomas P, Summer B, Pandit H, Taylor A, Beard D, Murray DW, Gill HS. Lymphocyte proliferation responses in patients with pseudotumors following metal-on-metal hip resurfacing arthroplasty. J Orthop Res 2010; 28:444-50. [PMID: 19834954 DOI: 10.1002/jor.21015] [Citation(s) in RCA: 146] [Impact Index Per Article: 10.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
Locally destructive soft tissue pseudotumor has been reported in patients following metal-on-metal hip resurfacing arthroplasty (MoMHRA). A delayed hypersensitivity reaction type IV to nickel (Ni), chromium (Cr), or cobalt (Co) has been suggested to play a role in its aetiology. The aim of this study was to investigate the incidence and level of metal-induced systemic hypersensitivity in patients with MoMHRA, both with and without pseudotumor by measuring lymphocyte proliferation responses to metals. A total of 92 patients were investigated: (1) MoMHRA patients with pseudotumors (nine female, one male); (2) MoMHRA patients without pseudotumors (30 female, 30 male); and (3) age-matched control subjects without metal implants (9 female, 13 male). The venous blood samples were collected for serum Ni, Co, and Cr ion level measurements and lymphocyte transformation tests (LTT). A higher incidence and level of enhanced lymphocyte reactivity only to Ni was found in patients with MoMHRA compared to the patients without MoM implants, reflecting exposure and immune reactivity. However, lymphocyte reactivity to Co, Cr, and Ni did not significantly differ in patients with pseudotumors compared to those patients without pseudotumors. This suggests that systemic hypersensitivity type IV reactions, as measured by lymphocyte proliferation response to these metals, may not be the dominant biological reaction involved in the occurrence of the soft tissue pseudotumors.
Collapse
Affiliation(s)
- Young-Min Kwon
- Nuffield Department of Orthopaedic Surgery, University of Oxford, Windmill Road, Oxford OX3 7LD, United Kingdom.
| | | | | | | | | | | | | | | |
Collapse
|
62
|
Hallab NJ, Caicedo M, Epstein R, McAllister K, Jacobs JJ. In vitro reactivity to implant metals demonstrates a person-dependent association with both T-cell and B-cell activation. J Biomed Mater Res A 2010; 92:667-82. [PMID: 19235773 PMCID: PMC2797558 DOI: 10.1002/jbm.a.32368] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Hypersensitivity to metallic implants remains relatively unpredictable and poorly understood. We initially hypothesized that metal-induced lymphocyte proliferation responses to soluble metal challenge (ions) are mediated exclusively by early T-cell activation (not B-cells), typical of a delayed-type-hypersensitivity response. We tested this by comparing proliferation (6 days) of primary lymphocytes with early T-cell and B-cell activation (48 h) in three groups of subjects likely to demonstrate elevated metal reactivity: group 1 (n = 12) history of metal sensitivity with no implant; group 2a (n = 6) well performing metal-on-metal THRs, and group 2b (n = 20) subjects with poorly performing metal-on-polymer total joint arthroplasties (TJA). Group 1 showed 100% (12/12) metal reactivity (stimulation index > 2) to Ni. Groups 2a and 2b were 83% (5/6) and 75% (15/22) metal reactive (to Co, Cr, or Ni), respectively. Of the n = 32 metal-reactive subjects to Co, Cr, or Ni (SI > 2), n = 22/32 demonstrated >2-fold elevations in % of T-cell or B-cell activation (CD25+, CD69+) to metal challenge when compared with untreated control. 18/22 metal-activated subjects demonstrated an exclusively T-cell or B-cell activation response to metal challenge, where 6/18 demonstrated exclusively B-cell activation and 12/18 demonstrated a T-cell only response, as measured by surface activation markers CD25+ and CD69+. However, there was no direct correlation (R(2) < 0.1) between lymphocyte proliferation and % T-cell or B-cell activation (CD25+:CD69+). Proliferation assays (LTT) showed greater ability to detect metal reactivity than did subject-dependent results of flow-cytometry analysis of T-cell or B-cell activation. The high incidence of lymphocyte reactivity and activation indicate that more complex than initially hypothesized immune responses may contribute to the etiology of debris-induced osteolysis in metal-sensitive individuals.
Collapse
Affiliation(s)
- Nadim James Hallab
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, Illinois 60612, USA.
| | | | | | | | | |
Collapse
|
63
|
Langton DJ, Jameson SS, Joyce TJ, Hallab NJ, Natu S, Nargol AVF. Early failure of metal-on-metal bearings in hip resurfacing and large-diameter total hip replacement: A consequence of excess wear. ACTA ACUST UNITED AC 2010; 92:38-46. [PMID: 20044676 DOI: 10.1302/0301-620x.92b1.22770] [Citation(s) in RCA: 523] [Impact Index Per Article: 37.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
Early failure associated with adverse reactions to metal debris is an emerging problem after hip resurfacing but the exact mechanism is unclear. We analysed our entire series of 660 metal-on-metal resurfacings (Articular Surface Replacement (ASR) and Birmingham Hip Resurfacing (BHR)) and large-bearing ASR total hip replacements, to establish associations with metal debris-related failures. Clinical and radiological outcomes, metal ion levels, explant studies and lymphocyte transformation tests were performed. A total of 17 patients (3.4%) were identified (all ASR bearings) with adverse reactions to metal debris, for which revision was required. This group had significantly smaller components, significantly higher acetabular component anteversion, and significantly higher whole concentrations of blood and joint chromium and cobalt ions than asymptomatic patients did (all p < 0.001). Post-revision lymphocyte transformation tests on this group showed no reactivity to chromium or cobalt ions. Explants from these revisions had greater surface wear than retrievals for uncomplicated fractures. The absence of adverse reactions to metal debris in patients with well-positioned implants usually implies high component wear. Surgeons must consider implant design, expected component size and acetabular component positioning in order to reduce early failures when performing large-bearing metal-on-metal hip resurfacing and replacement.
Collapse
Affiliation(s)
- D J Langton
- North Tees and Hartlepool NHS Trust, Stockton-on-Tees and Centre for Rehabilitation, Newcastle University, Newcastle upon Tyne, England.
| | | | | | | | | | | |
Collapse
|
64
|
Jameson SS, Langton DJ, Nargol AVF. Articular Surface Replacement of the hip: a prospective single-surgeon series. ACTA ACUST UNITED AC 2010; 92:28-37. [DOI: 10.1302/0301-620x.92b1.22769] [Citation(s) in RCA: 57] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
We present the early clinical and radiological results of Articular Surface Replacement (ASR) resurfacings in 214 hips (192 patients) with a mean follow-up of 43 months (30 to 57). The mean age of the patients was 56 years (28 to 74) and 85 hips (40%) were in 78 women. The mean Harris hip score improved from 52 (11 to 81) to 95 (27 to 100) at two years and the mean University of California, Los Angeles activity score from 3.9 (1 to 10) to 7.4 (2 to 10) in the same period. Narrowing of the neck (to a maximum of 9%) was noted in 124 of 209 hips (60%). There were 12 revisions (5.6%) involving four (1.9%) early fractures of the femoral neck and two (0.9%) episodes of collapse of the femoral head secondary to avascular necrosis. Six patients (2.8%) had failure related to metal wear debris. The overall survival for our series was 93% (95% confidence interval 80 to 98) and 89% (95% confidence interval 82 to 96) for hips with acetabular components smaller than 56 mm in diameter. The ASR implant has a lower diametrical clearance and a subhemispherical acetabular component when compared with other more frequently implanted metal-on-metal hip resurfacings. These changes may contribute to the higher failure rate than in other series, compared with other designs. Given our poor results with the small components we are no longer implanting the smaller size.
Collapse
Affiliation(s)
- S. S. Jameson
- Joint Replacement Unit, University Hospital of North Tees, Hardwick, Stockton-on-Tees TS19 8PE, UK
| | - D. J. Langton
- Joint Replacement Unit, University Hospital of North Tees, Hardwick, Stockton-on-Tees TS19 8PE, UK
| | - A. V. F. Nargol
- Joint Replacement Unit, University Hospital of North Tees, Hardwick, Stockton-on-Tees TS19 8PE, UK
| |
Collapse
|
65
|
Afolaranmi GA, Tettey JNA, Murray HM, Meek RMD, Grant MH. The effect of anticoagulants on the distribution of chromium VI in blood fractions. J Arthroplasty 2010; 25:118-20. [PMID: 19056207 DOI: 10.1016/j.arth.2008.10.012] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/14/2008] [Revised: 07/08/2008] [Accepted: 10/20/2008] [Indexed: 02/01/2023] Open
Abstract
Metal-on-metal resurfacing arthroplasty is associated with elevated circulating levels of cobalt and chromium ions. To establish the long-term safety of metal-on-metal resurfacing arthroplasty, it has been recommended that during clinical follow-up of these patients, the levels of these metal ions in blood be monitored. In this article, we provide information on the distribution of chromium VI ions (the predominant form of chromium released by cobalt-chrome alloys in vivo and in vitro) in blood fractions. Chromium VI is predominantly partitioned into red blood cells compared with plasma (analysis of variance, P < .05). The extent of accumulation in red blood cells is influenced by the anticoagulant used to collect the blood, with EDTA giving a lower partitioning into red cells compared with sodium citrate and sodium heparin.
Collapse
Affiliation(s)
- Grace A Afolaranmi
- Strathclyde Institute of Pharmacy and Biomedical Sciences, University of Strathclyde, Glasgow, UK
| | | | | | | | | |
Collapse
|
66
|
|
67
|
Penny JÃ, Overgaard S. Serum chromium levels sampled with steel needle versus plastic IV cannula. Does method matter? J Biomed Mater Res B Appl Biomater 2010; 92:1-4. [DOI: 10.1002/jbm.b.31479] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
68
|
Investigating the immunologic effects of CoCr nanoparticles. Clin Orthop Relat Res 2009; 467:3010-6. [PMID: 19565304 PMCID: PMC2758989 DOI: 10.1007/s11999-009-0949-9] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/20/2008] [Accepted: 06/10/2009] [Indexed: 01/31/2023]
Abstract
The increase in metal-on-metal hip arthroplasties has led to concern regarding the effect of raised serum and tissue metal ion levels. Our aim was to determine changes in the integrity and function of cells of the immune system after exposure to CoCr nanoparticles in specific cell culture experiments. Nanometer-sized particles of CoCr were made from a manufacturer's forged CoCr used for metal-on-metal articulations. Primary, murine dendritic cells and T and B lymphocytes then were exposed to these CoCr particles under cell culture conditions and then assayed for viability and proliferation/activation. CoCr nanoparticles did not directly activate dendritic cells or regulate B cells. Although nanoparticles were not directly toxic to resting T cells, Signals 1- and 2-dependent T cell proliferation were reduced. This may explain the observed reduction in CD8+ T cells observed in patients with metal-on-metal implants.
Collapse
|
69
|
Isaac GH, Brockett C, Breckon A, van der Jagt D, Williams S, Hardaker C, Fisher J, Schepers A. Ceramic-on-metal bearings in total hip replacement: whole blood metal ion levels and analysis of retrieved components. ACTA ACUST UNITED AC 2009; 91:1134-41. [PMID: 19721036 DOI: 10.1302/0301-620x.91b9.22306] [Citation(s) in RCA: 39] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
This study reports on ceramic-on-metal (CoM) bearings in total hip replacement. Whole blood metal ion levels were measured. The median increase in chromium and cobalt at 12 months was 0.08 microg/1 and 0.22 microg/1, respectively, in CoM bearings. Comparable values for metal-on-metal (MoM) were 0.48 microg/1 and 0.32 microg/1. The chromium levels were significantly lower in CoM than in MoM bearings (p = 0.02). The cobalt levels were lower, but the difference was not significant. Examination of two explanted ceramic heads revealed areas of thin metal transfer. CoM bearings (one explanted head and acetabular component, one explanted head and new acetabular component, and three new heads and acetabular components) were tested in a hip joint simulator. The explanted head and acetabular component had higher bedding-in. However, after one million cycles all the wear rates were the same and an order of magnitude less than that reported for MoM bearings. There were four outliers in each clinical group, primarily related to component malposition.
Collapse
Affiliation(s)
- G H Isaac
- DePuy International Ltd., Number 1 White Rose Office Park, Leeds LS11 0BG, UK.
| | | | | | | | | | | | | | | |
Collapse
|
70
|
Dahlstrand H, Stark A, Anissian L, Hailer NP. Elevated serum concentrations of cobalt, chromium, nickel, and manganese after metal-on-metal alloarthroplasty of the hip: a prospective randomized study. J Arthroplasty 2009; 24:837-45. [PMID: 18823744 DOI: 10.1016/j.arth.2008.07.019] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/03/2007] [Revised: 05/17/2008] [Accepted: 07/29/2008] [Indexed: 02/01/2023] Open
Abstract
In this prospective randomized study, we investigate metal ion concentrations and clinical outcome 2 years after metal-on-metal (28 patients) or metal-on-polyethylene (26 patients) hip arthroplasty with 28-mm modular heads. Metal ion concentrations in patient serum were analyzed by high-resolution plasma mass spectrometry. The clinical outcome was almost identical in both groups with respect to the Harris hip score and the Medical Outcome Study Short Form-36; and on plain radiography, no signs of loosening occurred in any group. In the metal-on-metal group, concentrations of all investigated ions increased significantly when compared with preoperative values: cobalt, 15.3-fold (95% confidence interval [CI], 9.4-21.2); chromium, 5.2-fold (CI, 3.5-7.0); nickel, 2.1-fold (CI, 1.2-3.0); and manganese, 1.6-fold (CI, 1.3-2.0). In the metal-on-polyethylene group, a smaller but significant increase in the concentrations of cobalt and nickel occurred, whereas concentrations of the other ions did not change significantly.
Collapse
Affiliation(s)
- Henrik Dahlstrand
- Department of Molecular Medicine and Surgery, Section of Orthopaedics, Karolinska Institute, Karolinska University Hospital, Stockholm, Sweden
| | | | | | | |
Collapse
|
71
|
Hart AJ, Skinner JA, Winship P, Faria N, Kulinskaya E, Webster D, Muirhead-Allwood S, Aldam CH, Anwar H, Powell JJ. Circulating levels of cobalt and chromium from metal-on-metal hip replacement are associated with CD8+ T-cell lymphopenia. ACTA ACUST UNITED AC 2009; 91:835-42. [PMID: 19483243 DOI: 10.1302/0301-620x.91b6.21844] [Citation(s) in RCA: 76] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
We carried out a cross-sectional study with analysis of the demographic, clinical and laboratory characteristics of patients with metal-on-metal hip resurfacing, ceramic-on-ceramic and metal-on-polyethylene hip replacements. Our aim was to evaluate the relationship between metal-on-metal replacements, the levels of cobalt and chromium ions in whole blood and the absolute numbers of circulating lymphocytes. We recruited 164 patients (101 men and 63 women) with hip replacements, 106 with metal-on-metal hips and 58 with non-metal-on-metal hips, aged < 65 years, with a pre-operative diagnosis of osteoarthritis and no pre-existing immunological disorders. Laboratory-defined T-cell lymphopenia was present in 13 patients (15%) (CD8(+) lymphopenia) and 11 patients (13%) (CD3(+) lymphopenia) with unilateral metal-on-metal hips. There were significant differences in the absolute CD8(+) lymphocyte subset counts for the metal-on-metal groups compared with each control group (p-values ranging between 0.024 and 0.046). Statistical modelling with analysis of covariance using age, gender, type of hip replacement, smoking and circulating metal ion levels, showed that circulating levels of metal ions, especially cobalt, explained the variation in absolute lymphocyte counts for almost all lymphocyte subsets.
Collapse
Affiliation(s)
- A J Hart
- Department of Musculoskeletal Surgery (Charing Cross), Imperial College, London, England.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
72
|
Response to chronic exposure to hexavalent chromium in human monocytes. Toxicol In Vitro 2009; 23:647-52. [DOI: 10.1016/j.tiv.2009.03.002] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2009] [Revised: 03/04/2009] [Accepted: 03/05/2009] [Indexed: 11/19/2022]
|
73
|
Zeh A, Becker C, Planert M, Lattke P, Wohlrab D. Time-dependent release of cobalt and chromium ions into the serum following implantation of the metal-on-metal Maverick type artificial lumbar disc (Medtronic Sofamor Danek). Arch Orthop Trauma Surg 2009; 129:741-6. [PMID: 18592257 DOI: 10.1007/s00402-008-0677-8] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/02/2008] [Indexed: 11/29/2022]
Abstract
INTRODUCTION In total hip endoprosthetics and consequently for TDA, metal-on-metal combinations are used with the aim of reducing wear debris. In metal-on-metal TDA the release of metal ions has until now been secondary to the main discussion. MATERIALS AND METHODS In order to investigate the ion release following the implantation of the metal-on-metal Maverick type artificial lumbar disc we measured the serum cobalt and chromium concentration following implantation of 15 Maverick TDAs (monosegmental L5/S1, n = 5; bisegmental L4/5 and L5/S1, n = 5; average age 36.5 years). Five healthy subjects (no metal implants) acted as a control group. The two measurements of the metals were carried out using the absorption spectrometry after an average of 14.8 and 36.7 months. RESULTS In summary, the concentrations of cobalt and chromium ions in the serum at both follow-ups amounted on average to 3.3 microg/l (SD 2.6) for cobalt and 2.2 microg/l (SD 1.5) for chromium. These figures are similar to the figures shown in the literature following the implantation of metal-on-metal THA. After a comparison to the control group, both the chromium and cobalt levels in the serum showed visible increases regarding the first and the second follow-up. DISCUSSION As there is still a significant release of cobalt and chromium into the serum after an average follow-up of 36.7 months a persistent release of these ions must be taken into consideration. Despite the evaluation of the systemic and local effects of the release of Cr/Co from orthopaedic implants has not yet been concluded, one should take into consideration an explanation given to patients scheduled for the implantation of a metal-on-metal TDA about these results and the benefits/risks of alternative combinations of gliding contact surfaces.
Collapse
Affiliation(s)
- Alexander Zeh
- Department of Orthopedics and Traumatology, Martin-Luther-University of Halle-Wittenberg, Faculty of Medicine, Halle/Saale, Germany.
| | | | | | | | | |
Collapse
|
74
|
Singh N, Manshian B, Jenkins GJS, Griffiths SM, Williams PM, Maffeis TGG, Wright CJ, Doak SH. NanoGenotoxicology: the DNA damaging potential of engineered nanomaterials. Biomaterials 2009; 30:3891-914. [PMID: 19427031 DOI: 10.1016/j.biomaterials.2009.04.009] [Citation(s) in RCA: 671] [Impact Index Per Article: 44.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2009] [Accepted: 04/13/2009] [Indexed: 01/13/2023]
Abstract
With the rapid expansion in the nanotechnology industry, it is essential that the safety of engineered nanomaterials and the factors that influence their associated hazards are understood. A vital area governing regulatory health risk assessment is genotoxicology (the study of genetic aberrations following exposure to test agents), as DNA damage may initiate and promote carcinogenesis, or impact fertility. Of late, considerable attention has been given to the toxicity of engineered nanomaterials, but the importance of their genotoxic potential on human health has been largely overlooked. This comprehensive review focuses on the reported abilities of metal nanoparticles, metal-oxide nanoparticles, quantum dots, fullerenes, and fibrous nanomaterials, to damage or interact with DNA, and their ecogenotoxicity is also considered. Many of the engineered nanomaterials assessed were found to cause genotoxic responses, such as chromosomal fragmentation, DNA strand breakages, point mutations, oxidative DNA adducts and alterations in gene expression profiles. However, there are clear inconsistencies in the literature and it is difficult to draw conclusions on the physico-chemical features of nanomaterials that promote genotoxicity, largely due to study design. Hence, areas that require that further attention are highlighted and recommendations to improve our understanding of the genotoxic potential of engineered nanomaterials are addressed.
Collapse
Affiliation(s)
- Neenu Singh
- Institute of Life Science, School of Medicine, Swansea University, Singleton Park, Swansea SA2 8PP, Wales, UK
| | | | | | | | | | | | | | | |
Collapse
|
75
|
Hart AJ, Buddhdev P, Winship P, Faria N, Powell JJ, Skinner JA. Cup inclination angle of greater than 50 degrees increases whole blood concentrations of cobalt and chromium ions after metal-on-metal hip resurfacing. Hip Int 2009; 18:212-9. [PMID: 18924077 DOI: 10.1177/112070000801800304] [Citation(s) in RCA: 87] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
A cup inclination angle greater than 45 degrees is associated with increased wear rates of metal on polyethylene (MOP) hip replacements. The same maybe true for metal on metal (MOM) hips yet this has not been clearly shown. We measured the acetabular inclination angle from plain radiographs, and whole blood metal ion levels using Inductively Coupled Plasma Mass Spectrometry of 26 patients (mean Harris Hip Score 94 and mean time post op of 22 months) with Birmingham Hip Resurfacings. We identified a threshold level of 50 degrees cup inclination. Below this threshold, the mean whole blood cobalt and chromium were 1.6 ppb and 1.88 ppb respectively; above this threshold, the mean blood cobalt and chromium were 4.45 ppb and 4.3 ppb respectively. These differences were significant cobalt (p<0.01) and chromium (p=0.01). All patients above the threshold had metal levels greater than any of the patients below the threshold. For 14 patients, who returned one year later for a repeat blood metal level measurement, cobalt and chromium levels were very similar. The effect of an acetabular inclination angle of greater than 50 degrees on wear rates of MOM hips, as measured through blood metal ion levels, appears to be similar to that seen with MOP hips. Additionally, our new analytical methods may allow blood metal levels to be used as a realistic biomarker of in vivo wear rate of MOM hips. The implication is that metal levels can be minimised with optimal orientation of the acetabular component.
Collapse
Affiliation(s)
- A J Hart
- Department of Musculoskeletal Surgery, Imperial College Healthcare NHS Trust, Charing Cross Hospital, London, UK.
| | | | | | | | | | | |
Collapse
|
76
|
Abstract
We report a case of metal-on-metal hip resurfacing complicated by a reactive synovitis and a large effusion resulting in dislocation, peripheral oedema and groin discomfort. Histological analysis of the retrieved specimens revealed an intense lymphocytosis. Conversion to a traditional hip replacement resulted in resolution of the symptoms.
Collapse
Affiliation(s)
- A Peacock
- Heart of England NHS Trust and University of Birmingham Medical School, Birmingham, UK
| | | | | |
Collapse
|
77
|
Daniel J, Ziaee H, Pradhan C, McMinn DJW. Six-year results of a prospective study of metal ion levels in young patients with metal-on-metal hip resurfacings. ACTA ACUST UNITED AC 2009; 91:176-9. [PMID: 19190049 DOI: 10.1302/0301-620x.91b2.21654] [Citation(s) in RCA: 85] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
We describe the findings at six years in an ongoing prospective clinicoradiological and metal ion study in a cohort of 26 consecutive male patients with unilateral Birmingham Hip Resurfacing arthroplasties with one of two femoral head sizes (50 mm and 54 mm). Their mean age was 52.9 years (29 to 67). We have previously shown an early increase in the 24-hour urinary excretion of metal ions, reaching a peak at six months (cobalt) and one year (chromium) after operation. Subsequently there is a decreasing trend in excretion of both cobalt and chromium. The levels of cobalt and chromium in whole blood also show a significant increase at one year, followed by a decreasing trend until the sixth year.
Collapse
Affiliation(s)
- J Daniel
- The McMinn Centre, 25 Highfield Road, Birmingham B15 3DP, UK.
| | | | | | | |
Collapse
|
78
|
Raghunathan VK, Tettey JNA, Ellis EM, Grant MH. Comparative chronicin vitrotoxicity of hexavalent chromium to osteoblasts and monocytes. J Biomed Mater Res A 2009; 88:543-50. [DOI: 10.1002/jbm.a.31893] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
79
|
2008 John Charnley award: metal ion levels after metal-on-metal total hip arthroplasty: a randomized trial. Clin Orthop Relat Res 2009; 467:101-11. [PMID: 18855089 PMCID: PMC2600985 DOI: 10.1007/s11999-008-0540-9] [Citation(s) in RCA: 90] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/31/2008] [Accepted: 09/10/2008] [Indexed: 01/31/2023]
Abstract
UNLABELLED Metal-on-metal bearing total hip arthroplasty is performed more commonly than in the past. There may be manufacturing differences such as clearance, roughness, metallurgy, and head size that affect performance. In a prospective, randomized trial, we compared 2-year postoperative ion levels for a 28-mm metal-on-polyethylene bearing with 28-mm and 36-mm metal-on-metal bearings. We measured serum, erythrocyte, and urine ion levels. We observed no difference in the ion levels for the 28-mm and 36-mm metal-on-metal bearings. The ion levels in these patients were lower than reported for most other metal-on-metal bearings. Although both erythrocyte and serum cobalt increased, erythrocyte chromium and erythrocyte titanium did not increase despite a four- to sixfold serum chromium and a three- to fourfold serum titanium increase. This may represent a threshold level for serum chromium and serum titanium below which erythrocytes are not affected. LEVEL OF EVIDENCE Level I, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.
Collapse
|
80
|
Revell PA. The combined role of wear particles, macrophages and lymphocytes in the loosening of total joint prostheses. J R Soc Interface 2008; 5:1263-78. [PMID: 18647740 PMCID: PMC2607446 DOI: 10.1098/rsif.2008.0142] [Citation(s) in RCA: 114] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022] Open
Abstract
This review considers the causes of loosening of prosthetic joint replacement paying attention to the biological mechanisms rather than other effects that are physical, such as component fracture and other failure related to mechanical problems. Infection accounts for approximately 1.5 per cent of joint loosening and when it occurs it is a cause of serious concern to the surgeon. The loosening of prosthetic joints in the absence of infection is by far the most common reason for revision surgery and is known as aseptic loosening. While this may be multifactorial in terms of causation, and non-biological factors may contribute significantly in a particular individual, a significant part is undoubtedly played by the generation of wear debris, mainly from the bearing surfaces of the joint, and the cellular reaction to this in the implant bed. Phagocytic cells (macrophages and multinucleated giant cells) are the ones that remove foreign material from the tissues, and the ways in which these cells function in the interface between implant and bone are described. Mediators produced locally include numerous cytokines, enzymes and integrins. There is evidence for interactions between macrophages and locally recruited lymphocytes, which may or may not give rise to an immunologically mediated process.Sensitization of individuals having metal implants in place has been shown by positive skin tests or blood lymphocyte transformation tests and in these cases has been accompanied by loosening and failure of the replacement joint. The question remains as to whether this process is also present in a proportion of individuals with aseptic loosening in the absence of clearly defined clinical evidence of sensitization.Numerous studies performed by the author's group and, latterly, by others suggest that the cellular reactions detected in the tissues in cases of aseptic loosening are indeed those of contact sensitization. There is good evidence to show that a type IV cell-mediated immune reaction is taking place, with TH1 cell involvement and active antigen presentation. The extent to which sensitization is present in individual cases of aseptic loosening remains a subject for further work and this needs all the sophisticated molecular methods now available to modern biology to be applied in appropriate prospective clinical studies coupled with experimental models in vitro and in vivo. Immunological processes may play a more important part in joint loosening than previously considered.
Collapse
Affiliation(s)
- Peter A Revell
- Division of Biomaterials and Tissue Engineering, Eastman Dental Institute, University College London, London, UK.
| |
Collapse
|
81
|
Mabilleau G, Kwon YM, Pandit H, Murray DW, Sabokbar A. Metal-on-metal hip resurfacing arthroplasty: a review of periprosthetic biological reactions. Acta Orthop 2008; 79:734-47. [PMID: 19085489 DOI: 10.1080/17453670810016795] [Citation(s) in RCA: 112] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
Metal-on-metal hip resurfacing arthroplasty has undergone a recent resurgence as an alternative treatment option for young and active patients with significant osteoarthritis. The claimed advantages of metal-on-metal hip resurfacing arthroplasty include lower wear rate, preservation of bone stock for subsequent revision procedures, restoration of anatomic hip mechanics, and enhanced stability due to the larger diameter of articulation. A disadvantage, however, is that the metal-on-metal resurfacing releases large amounts of very small wear particles and metal ions. The long-term biological consequences of the exposure to these Co-Cr particles and ions remain largely unknown. The purpose of this review is to provide an overview of the current literature on the adverse periprosthetic biological reactions associated with metal-on-metal hip resurfacing arthroplasty.
Collapse
Affiliation(s)
- Guillaume Mabilleau
- Nuffield Department of Orthopaedic Surgery, Institute of Musculoskeletal Science, Botnar Research Centre, University of Oxford, Oxford, UK.
| | | | | | | | | |
Collapse
|
82
|
Whittingham-Jones PM, Dunstan E, Altaf H, Cannon SR, Revell PA, Briggs TWR. Immune responses in patients with metal-on-metal hip articulations: a long-term follow-up. J Arthroplasty 2008; 23:1212-8. [PMID: 18534468 DOI: 10.1016/j.arth.2007.10.015] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/06/2007] [Revised: 09/27/2007] [Accepted: 10/14/2007] [Indexed: 02/01/2023] Open
Abstract
Metal-on-metal (MoM) hip bearings are being inserted into ever-younger patients. The effects on the immune system of chronic exposure are unknown. We investigated the immune response of patients with MoM hip bearings. In patients with MoM implants, the expression of antigen-presenting cell (APC) surface molecules (CD86 and HLA-DR) was seen to be significantly higher (P < .05) than control group. High levels of APC surface molecules suggest an activated state and attempts to propagate an immune response. However, in the same group, the expression of T-cell markers (CD3 and CD28) was low, indicating a small T-cell population. This suggests, despite the activation of APCs, that T cells down-regulate immune responses in MoM articulations. Conversely, in metal-on-polyethylene articulations, expression of T-cell molecules was elevated and expression of APC molecules lowered.
Collapse
|
83
|
De Haan R, Pattyn C, Gill HS, Murray DW, Campbell PA, De Smet K. Correlation between inclination of the acetabular component and metal ion levels in metal-on-metal hip resurfacing replacement. ACTA ACUST UNITED AC 2008; 90:1291-7. [PMID: 18827237 DOI: 10.1302/0301-620x.90b10.20533] [Citation(s) in RCA: 360] [Impact Index Per Article: 22.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
We examined the relationships between the serum levels of chromium and cobalt ions and the inclination angle of the acetabular component and the level of activity in 214 patients implanted with a metal-on-metal resurfacing hip replacement. Each patient had a single resurfacing and no other metal in their body. All serum measurements were performed at a minimum of one year after operation. The inclination of the acetabular component was considered to be steep if the abduction angle was greater than 55 degrees. There were significantly higher levels of metal ions in patients with steeply-inclined components (p = 0.002 for chromium, p = 0.003 for cobalt), but no correlation was found between the level of activity and the concentration of metal ions. A highly significant (p < 0.001) correlation with the arc of cover was found. Arcs of cover of less than 10 mm were correlated with a greater risk of high concentrations of serum metal ions. The arc of coverage was also related to the design of the component and to size as well as to the abduction angle of the acetabular component. Steeply-inclined acetabular components, with abduction angles greater than 55 degrees, combined with a small size of component are likely to give rise to higher serum levels of cobalt and chromium ions. This is probably due to a greater risk of edge-loading.
Collapse
Affiliation(s)
- R De Haan
- University Hospital Brussels, Laarbeeklaan 101, 1090 Brussels, Belgium.
| | | | | | | | | | | |
Collapse
|
84
|
Keegan GM, Learmonth ID, Case C. A Systematic Comparison of the Actual, Potential, and Theoretical Health Effects of Cobalt and Chromium Exposures from Industry and Surgical Implants. Crit Rev Toxicol 2008; 38:645-74. [DOI: 10.1080/10408440701845534] [Citation(s) in RCA: 116] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
|
85
|
Cazenave A. [Dissociation of the acetabular metallic inlay of a metal-on-metal total hip arthroplasty]. ACTA ACUST UNITED AC 2008; 94:399-402. [PMID: 18555867 DOI: 10.1016/j.rco.2008.01.004] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/22/2008] [Indexed: 10/22/2022]
Abstract
Total hip arthroplasty was performed in November 2001 in a 30-year-old active patient with degenerative hip disease. A metal-on-metal bearing was used. Follow-up was considered excellent until the development of pain and squeaking at hip mobilization, leading to revision in March 2006. The acetabular metallic inlay of the metal-on-metal insert was found detached from the polyethylene insert; half of the diameter of the neck of the femoral stem was sectioned. Complete revision was performed with an acetabular graft. At one year follow-up, anatomic and functional outcome has been excellent. To our knowledge, this is the first report of this kind of mechanical failure of a metal-on-metal total hip arthroplasty.
Collapse
Affiliation(s)
- A Cazenave
- Service de Chirurgie Orthopédique des Membres, Institut Calot, Berck-Sur-Mer, France.
| |
Collapse
|
86
|
Afolaranmi G, Tettey J, Meek R, Grant M. Release of chromium from orthopaedic arthroplasties. Open Orthop J 2008; 2:10-8. [PMID: 19461924 PMCID: PMC2685051 DOI: 10.2174/1874325000802010010] [Citation(s) in RCA: 37] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/06/2007] [Revised: 12/10/2007] [Accepted: 01/04/2008] [Indexed: 12/12/2022] Open
Abstract
Many orthopaedic implants are composed of alloys containing chromium. Of particular relevance is the increasing number of Cobalt Chromium bearing arthroplasies being inserted into young patients with osteoarthritis. Such implants will release chromium ions. These patients will be exposed to the released chromium for over 50 years in some cases. The subsequent chromium ion metabolism and redistribution in fluid and tissue compartments is complex. In addition, the potential biological effects of chromium are also controversial, including DNA and chromosomal damage, reduction in CD8 lymphocyte levels and possible hypersensitivity reactions (ALVAL). The establishment of these issues and the measurement of chromium in biological fluids is the subject of this review.
Collapse
Affiliation(s)
| | - J Tettey
- Strathclyde Institute of Pharmacy and Biomedical Sciences
| | - R.M.D Meek
- Department of Orthopaedic Surgery, Southern General Hospital, Glasgow, UK
| | - M.H Grant
- Bioengineering Unit, University of Strathclyde, UK
| |
Collapse
|
87
|
What are the local and systemic biologic reactions and mediators to wear debris, and what host factors determine or modulate the biologic response to wear particles? J Am Acad Orthop Surg 2008; 16 Suppl 1:S42-8. [PMID: 18612013 PMCID: PMC2714366 DOI: 10.5435/00124635-200800001-00010] [Citation(s) in RCA: 100] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023] Open
Abstract
New clinical and basic science data on the cellular and molecular mechanisms by which wear particles stimulate the host inflammatory response have provided deeper insight into the pathophysiology of periprosthetic bone loss. Interactions among wear particles, macrophages, osteoblasts, bone marrow-derived mesenchymal stem cells, fibroblasts, endothelial cells, and T cells contribute to the production of pro-inflammatory and pro-osteoclastogenic cytokines such as TNF-alpha, RANKL, M-SCF, PGE2, IL-1, IL-6, and IL-8. These cytokines not only promote osteoclastogenesis but interfere with osteogenesis led by osteoprogenitor cells. Recent studies indicate that genetic variations in TNF-alpha, IL-1, and FRZB can result in subtle changes in gene function, giving rise to altered susceptibility or severity for periprosthetic inflammation and bone loss. Continuing research on the biologic effects and mechanisms of action of wear particles will provide a rational basis for the development of novel and effective ways of diagnosis, prevention, and treatment of periprosthetic inflammatory bone loss.
Collapse
|
88
|
Abstract
This paper considers the increased risk of the development of lymphoma in patients with chronic inflammatory disease who undergo metal-on-metal arthroplasty.
Collapse
Affiliation(s)
- L. Lidgren
- Department of Orthopaedics and Clinical Sciences, Lund University Hospital, SE-221 85 Lund, Sweden
| |
Collapse
|
89
|
Mont MA, Seyler TM, Ulrich SD, Beaule PE, Boyd HS, Grecula MJ, Goldberg VM, Kennedy WR, Marker DR, Schmalzried TP, Sparling EA, Vail TP, Amstutz HC. Effect of changing indications and techniques on total hip resurfacing. Clin Orthop Relat Res 2007; 465:63-70. [PMID: 17891034 DOI: 10.1097/blo.0b013e318159dd60] [Citation(s) in RCA: 102] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
Recently, improved metal-on-metal bearing technology has led to the reemergence of resurfacing as a reasonable option for total hip arthroplasty. During the course of a prospective multicenter FDA-IDE evaluation of metal-on-metal total hip resurfacings, we modified our indications and emphasized surgical technique where the femoral surface area was small due to femoral cysts and small component size. We assessed the influence of these changes on complication rates in the first cohort of 292 patients and the second of 724, and then compared these outcomes in the second cohort with historical reports of resurfacing. We had a minimum followup of 24 months (mean, 33 months; range, 24-60 months). After changes were made in the indications and technique, the overall complication rate decreased from 13.4% to 2.1% with the femoral neck fracture rate reduced from 7.2% to 0.8%. The outcomes of the second cohort compare with modern-day resurfacing devices and appear superior to historical results. The data suggest patients should be carefully selected and technique optimized to reduce complications. Long-term followup is required to see if these promising results will be maintained.
Collapse
Affiliation(s)
- Michael A Mont
- The Center for Joint Preservation and Reconstruction, Rubin Institute for Advanced Orthopedics, Sinai Hospital of Baltimore, Baltimore, MD 21215, USA.
| | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
90
|
Anwar HA, Aldam CH, Visuvanathan S, Hart AJ. The effect of metal ions in solution on bacterial growth compared with wear particles from hip replacements. ACTA ACUST UNITED AC 2007; 89:1655-9. [DOI: 10.1302/0301-620x.89b12.19714] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
The biological significance of cobalt-chromium wear particles from metal-on-metal hip replacements may be different to the effects of the constituent metal ions in solution. Bacteria may be able to discriminate between particulate and ionic forms of these metals because of a transmembrane nickel/cobalt-permease. It is not known whether wear particles are bacteriocidal. We compared the doubling time of coagulase negative staphylococcus, Staphylococcus aureus and methicillin resistant S. aureus when cultured in either wear particles from a metal-on-metal hip simulator, wear particles from a metal-on-polyethylene hip simulator, metal ions in solution or a control. Doubling time halved in metal-on-metal (p = 0.003) and metal-on-polyethylene (p = 0.131) particulate debris compared with the control. Bacterial nickel/cobalt-transporters allow metal ions but not wear particles to cross bacterial membranes. This may be useful for testing the biological characteristics of different wear debris. This experiment also shows that metal-on-metal hip wear debris is not bacteriocidal.
Collapse
Affiliation(s)
- H. A. Anwar
- The Princess Alexandra Hospital NHS Trust, Hamstel Road, Harlow CM20 1QX, UK
| | - C. H. Aldam
- The Princess Alexandra Hospital NHS Trust, Hamstel Road, Harlow CM20 1QX, UK
| | - S. Visuvanathan
- The Princess Alexandra Hospital NHS Trust, Hamstel Road, Harlow CM20 1QX, UK
| | - A. J. Hart
- Imperial College, London (Charing Cross Campus), Fulham Palace Road, London W6 8RF, UK
| |
Collapse
|
91
|
Sauvé P, Mountney J, Khan T, De Beer J, Higgins B, Grover M. Metal ion levels after metal-on-metal Ring total hip replacement: a 30-year follow-up study. ACTA ACUST UNITED AC 2007; 89:586-90. [PMID: 17540740 DOI: 10.1302/0301-620x.89b5.18457] [Citation(s) in RCA: 40] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Metal-on-metal bearings for total hip replacement (THR) are becoming increasingly popular. Improved wear characteristics mean that these articulations are being inserted into younger patients in the form of THR and resurfacing procedures. This has led to concerns regarding potential carcinogenicity because of the increased exposure to metal ions that the procedure brings. We have studied the serum cobalt and chromium concentrations in patients who had primary, well-fixed Ring metal-on-metal THRs for more than 30 years. The levels of cobalt and chromium were elevated by five and three times, respectively compared with those in our reference groups. Metal-on-metal articulations appear to be the source of metal ions throughout the life of the prosthesis. In three patients who had undergone revision of a previous metal-on-metal THR to a metal-on-polyethylene replacement the levels of metal ions were within the normal range. The elevations of cobalt and chromium ions seen in our study were comparable with those in patients with modern metal-on-metal THRs.
Collapse
Affiliation(s)
- P Sauvé
- Portsmouth Hospitals NHS Trust, Queen Alexandra Hospital, Southwick Hill Road, Cosham PO6 3LY, United Kingdom.
| | | | | | | | | | | |
Collapse
|
92
|
Abstract
Total hip arthroplasty is one of the most commonly performed and successful elective orthopaedic procedures. However, numerous failure mechanisms limit the long-term success including aseptic osteolysis, aseptic loosening, infection, and implant instability. Aseptic osteolysis and subsequent implant failure occur because of a chronic inflammatory response to implant-derived wear particles. To reduce particulate debris and their consequences, implants have had numerous design modifications including high-molecular-weight polyethylene sockets and noncemented implants that rely on bone ingrowth for fixation. Surgical techniques have improved cementation with the use of medullary plugs, cement guns, lavage of the canal, pressurization, centralization of the stem, and reduction in cement porosity. Despite these advances, aseptic osteolysis continues to limit implant longevity. Numerous proinflammatory cytokines, such as interleukin-1, interleukin-6, tumor necrosis factor-alpha, and prostaglandin E2, have proosteoclastogenic effects in response to implant-derived wear particles. However, none of these cytokines represents a final common pathway for the process of particle-induced osteoclast differentiation and maturation. Recent work has identified the fundamental role of the RANKL-RANK-NF-kappaB pathway not only in osteoclastogenesis but also in the development and function the immune system. Thus, the immune system and skeletal homeostasis may be linked in the process of osteoclastogenesis and osteolysis.
Collapse
Affiliation(s)
- G Holt
- Department of Orthopaedic and Trauma Surgery, Southern General Hospital, Glasgow, Scotland, UK
| | | | | | | |
Collapse
|
93
|
Lalaouni A, Henderson C, Kupper C, Grant MH. The interaction of chromium (VI) with macrophages: Depletion of glutathione and inhibition of glutathione reductase. Toxicology 2007; 236:76-81. [PMID: 17498860 DOI: 10.1016/j.tox.2007.04.002] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2007] [Revised: 03/28/2007] [Accepted: 04/02/2007] [Indexed: 10/23/2022]
Abstract
There are reports of alterations in the number and functions of the cells of the immune system in patients with metal-on-metal (MOM) orthopaedic implants. These effects have been correlated with elevated chromium levels in the patients' blood. We have investigated the interactions of clinically relevant concentrations of Cr VI with macrophages in vitro, and the mechanisms responsible for its toxicity. Cr VI causes a concentration dependent decrease in macrophage viability above 1 microM as measured by the MTT and Neutral Red assays. This falls well within the range of circulating chromium serum concentrations measured in patients with MOM. Intracellular reduced glutathione (GSH) levels fall as a result, and most of the loss (86%) is accounted for by oxidation to the dimer, GSSG. Prior depletion of GSH does not sensitise the cells to Cr VI toxicity, implying that it is not involved in protecting the cells against the effects of Cr VI. During the metabolism of Cr VI, glutathione reductase activity is inhibited. In contrast, the activities of catalase and superoxide dismutase are not significantly altered. Prior inhibition of glutathione reductase activity protects against the toxicity of Cr VI to a significant extent, suggesting that it reduces Cr VI to a toxic metabolite.
Collapse
Affiliation(s)
- A Lalaouni
- Bioengineering Unit, University of Strathclyde, Wolfson Centre, Glasgow G4 0NW, United Kingdom
| | | | | | | |
Collapse
|
94
|
Keegan GM, Learmonth ID, Case CP. Orthopaedic metals and their potential toxicity in the arthroplasty patient. ACTA ACUST UNITED AC 2007; 89:567-73. [PMID: 17540737 DOI: 10.1302/0301-620x.89b5.18903] [Citation(s) in RCA: 208] [Impact Index Per Article: 12.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
The long-term effects of metal-on-metal arthroplasty are currently under scrutiny because of the potential biological effects of metal wear debris. This review summarises data describing the release, dissemination, uptake, biological activity, and potential toxicity of metal wear debris released from alloys currently used in modern orthopaedics. The introduction of risk assessment for the evaluation of metal alloys and their use in arthroplasty patients is discussed and this should include potential harmful effects on immunity, reproduction, the kidney, developmental toxicity, the nervous system and carcinogenesis.
Collapse
Affiliation(s)
- G M Keegan
- University of Bristol, Bristol Implant Research Centre, Avon Orthopaedic Centre (lower level), Southmead Hospital, Westbury-on-Trym, Bristol, BS10 5NB, UK.
| | | | | |
Collapse
|
95
|
Daniel J, Ziaee H, Pradhan C, Pynsent PB, McMinn DJW. Blood and urine metal ion levels in young and active patients after Birmingham hip resurfacing arthroplasty. ACTA ACUST UNITED AC 2007; 89:169-73. [PMID: 17322429 DOI: 10.1302/0301-620x.89b2.18519] [Citation(s) in RCA: 89] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
This is a longitudinal study of the daily urinary output and the concentrations in whole blood of cobalt and chromium in patients with metal-on-metal resurfacings over a period of four years. Twelve-hour urine collections and whole blood specimens were collected before and periodically after a Birmingham hip resurfacing in 26 patients. All ion analyses were carried out using a high-resolution inductively-coupled plasma mass spectrometer. Clinical and radiological assessment, hip function scoring and activity level assessment revealed excellent hip function. There was a significant early increase in urinary metal output, reaching a peak at six months for cobalt and one year for chromium post-operatively. There was thereafter a steady decrease in the median urinary output of cobalt over the following three years, although the differences are not statistically significant. The mean whole blood levels of cobalt and chromium also showed a significant increase between the pre-operative and one-year post-operative periods. The blood levels then decreased to a lower level at four years, compared with the one-year levels. This late reduction was statistically significant for chromium but not for cobalt. The effects of systemic metal ion exposure in patients with metal-on-metal resurfacing arthroplasties continue to be a matter of concern. The levels in this study provide a baseline against which the in vivo wear performance of newer bearings can be compared.
Collapse
Affiliation(s)
- J Daniel
- The McMinn Centre, 25 Highfield Road, Edgbaston, Birmingham B15 3DP, UK.
| | | | | | | | | |
Collapse
|