101
|
Mehta BB, Ma D, Pierre EY, Jiang Y, Coppo S, Griswold MA. Image reconstruction algorithm for motion insensitive MR Fingerprinting (MRF): MORF. Magn Reson Med 2018; 80:2485-2500. [PMID: 29732610 DOI: 10.1002/mrm.27227] [Citation(s) in RCA: 30] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2017] [Revised: 03/24/2018] [Accepted: 03/28/2018] [Indexed: 12/15/2022]
Abstract
PURPOSE The purpose of this study is to increase the robustness of MR fingerprinting (MRF) toward subject motion. METHODS A novel reconstruction algorithm, MOtion insensitive MRF (MORF), was developed, which uses an iterative reconstruction based retrospective motion correction approach. Each iteration loops through the following steps: pattern recognition, metric based identification of motion corrupted frames, registration based motion estimation, and motion compensated data consistency verification. The proposed algorithm was validated using in vivo 2D brain MRF data with retrospective in-plane motion introduced at different stages of the acquisition. The validation was performed using qualitative and quantitative comparisons between results from MORF, the iterative multi-scale (IMS) algorithm, and with the IMS results using data without motion for a ground truth comparison. Additionally, the MORF algorithm was evaluated in prospectively motion corrupted in vivo 2D brain MRF datasets. RESULTS For datasets corrupted by in-plane motion both prospectively and retrospectively, MORF noticeably reduced motion artifacts compared with iterative multi-scale and closely resembled the results from data without motion, even when ∼54% of data was motion corrupted during different parts of the acquisition. CONCLUSIONS MORF improves the insensitivity of MRF toward rigid-body motion occurring during any part of the MRF acquisition.
Collapse
Affiliation(s)
| | - Dan Ma
- Department of Radiology, Case Western Reserve University, Cleveland, Ohio
| | - Eric Yann Pierre
- Imaging Division, The Florey Institute of Neuroscience and Mental Health, Melbourne, Victoria, Australia
| | - Yun Jiang
- Department of Radiology, Case Western Reserve University, Cleveland, Ohio
| | - Simone Coppo
- Department of Radiology, Case Western Reserve University, Cleveland, Ohio
| | - Mark Alan Griswold
- Department of Radiology, Case Western Reserve University, Cleveland, Ohio.,Department of Biomedical Engineering, Case Western Reserve University, Cleveland, Ohio
| |
Collapse
|
102
|
Rieger B, Akçakaya M, Pariente JC, Llufriu S, Martinez-Heras E, Weingärtner S, Schad LR. Time efficient whole-brain coverage with MR Fingerprinting using slice-interleaved echo-planar-imaging. Sci Rep 2018; 8:6667. [PMID: 29703978 PMCID: PMC5923901 DOI: 10.1038/s41598-018-24920-z] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2017] [Accepted: 04/12/2018] [Indexed: 01/18/2023] Open
Abstract
Magnetic resonance fingerprinting (MRF) is a promising method for fast simultaneous quantification of multiple tissue parameters. The objective of this study is to improve the coverage of MRF based on echo-planar imaging (MRF-EPI) by using a slice-interleaved acquisition scheme. For this, the MRF-EPI is modified to acquire several slices in a randomized interleaved manner, increasing the effective repetition time of the spoiled gradient echo readout acquisition in each slice. Per-slice matching of the signal-trace to a precomputed dictionary allows the generation of T1 and T2* maps with integrated B1+ correction. Subsequent compensation for the coil sensitivity profile and normalization to the cerebrospinal fluid additionally allows for quantitative proton density (PD) mapping. Numerical simulations are performed to optimize the number of interleaved slices. Quantification accuracy is validated in phantom scans and feasibility is demonstrated in-vivo. Numerical simulations suggest the acquisition of four slices as a trade-off between quantification precision and scan-time. Phantom results indicate good agreement with reference measurements (Difference T1: -2.4 ± 1.1%, T2*: -0.5 ± 2.5%, PD: -0.5 ± 7.2%). In-vivo whole-brain coverage of T1, T2* and PD with 32 slices was acquired within 3:36 minutes, resulting in parameter maps of high visual quality and comparable performance with single-slice MRF-EPI at 4-fold scan-time reduction.
Collapse
Affiliation(s)
- Benedikt Rieger
- Computer Assisted Clinical Medicine, University Medical Center Mannheim, Heidelberg University, Mannheim, Germany
- Magnetic Resonance Image Core Facility, Institut d'Investigacions Biomèdiques August Pi i Sunyer (IDIBAPS), Barcelona, Spain
| | - Mehmet Akçakaya
- Electrical and Computer Engineering, University of Minnesota, Minneapolis, MN, United States
- Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, MN, United States
| | - José C Pariente
- Magnetic Resonance Image Core Facility, Institut d'Investigacions Biomèdiques August Pi i Sunyer (IDIBAPS), Barcelona, Spain
| | - Sara Llufriu
- Center of Neuroimmunology. Laboratory of Advanced Imaging in Neuroimmunological Diseases, Hospital Clinic Barcelona and Institut d'Investigacions Biomediques August Pi i Sunyer (IDIBAPS), Barcelona, Spain
| | - Eloy Martinez-Heras
- Center of Neuroimmunology. Laboratory of Advanced Imaging in Neuroimmunological Diseases, Hospital Clinic Barcelona and Institut d'Investigacions Biomediques August Pi i Sunyer (IDIBAPS), Barcelona, Spain
| | - Sebastian Weingärtner
- Computer Assisted Clinical Medicine, University Medical Center Mannheim, Heidelberg University, Mannheim, Germany.
- Electrical and Computer Engineering, University of Minnesota, Minneapolis, MN, United States.
- Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, MN, United States.
| | - Lothar R Schad
- Computer Assisted Clinical Medicine, University Medical Center Mannheim, Heidelberg University, Mannheim, Germany
| |
Collapse
|
103
|
Ma D, Jiang Y, Chen Y, McGivney D, Mehta B, Gulani V, Griswold M. Fast 3D magnetic resonance fingerprinting for a whole-brain coverage. Magn Reson Med 2018; 79:2190-2197. [PMID: 28833436 PMCID: PMC5868964 DOI: 10.1002/mrm.26886] [Citation(s) in RCA: 103] [Impact Index Per Article: 17.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2017] [Revised: 07/19/2017] [Accepted: 08/03/2017] [Indexed: 12/24/2022]
Abstract
PURPOSE The purpose of this study was to accelerate the acquisition and reconstruction time of 3D magnetic resonance fingerprinting scans. METHODS A 3D magnetic resonance fingerprinting scan was accelerated by using a single-shot spiral trajectory with an undersampling factor of 48 in the x-y plane, and an interleaved sampling pattern with an undersampling factor of 3 through plane. Further acceleration came from reducing the waiting time between neighboring partitions. The reconstruction time was accelerated by applying singular value decomposition compression in k-space. Finally, a 3D premeasured B1 map was used to correct for the B1 inhomogeneity. RESULTS The T1 and T2 values of the International Society for Magnetic Resonance in Medicine/National Institute of Standards and Technology MRI phantom showed a good agreement with the standard values, with an average concordance correlation coefficient of 0.99, and coefficient of variation of 7% in the repeatability scans. The results from in vivo scans also showed high image quality in both transverse and coronal views. CONCLUSIONS This study applied a fast acquisition scheme for a fully quantitative 3D magnetic resonance fingerprinting scan with a total acceleration factor of 144 as compared with the Nyquist rate, such that 3D T1 , T2 , and proton density maps can be acquired with whole-brain coverage at clinical resolution in less than 5 min. Magn Reson Med 79:2190-2197, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
Collapse
Affiliation(s)
- Dan Ma
- Department of Radiology, Case Western Reserve University, Cleveland, OH
| | - Yun Jiang
- Department of Radiology, Case Western Reserve University, Cleveland, OH
| | - Yong Chen
- Department of Radiology, Case Western Reserve University, Cleveland, OH
| | - Debra McGivney
- Department of Radiology, Case Western Reserve University, Cleveland, OH
| | - Bhairav Mehta
- Department of Radiology, Case Western Reserve University, Cleveland, OH
| | - Vikas Gulani
- Department of Radiology, Case Western Reserve University, Cleveland, OH
| | - Mark Griswold
- Department of Radiology, Case Western Reserve University, Cleveland, OH
| |
Collapse
|
104
|
Liao C, Bilgic B, Manhard MK, Zhao B, Cao X, Zhong J, Wald LL, Setsompop K. 3D MR fingerprinting with accelerated stack-of-spirals and hybrid sliding-window and GRAPPA reconstruction. Neuroimage 2017; 162:13-22. [PMID: 28842384 PMCID: PMC6031129 DOI: 10.1016/j.neuroimage.2017.08.030] [Citation(s) in RCA: 78] [Impact Index Per Article: 11.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2017] [Revised: 07/02/2017] [Accepted: 08/09/2017] [Indexed: 12/13/2022] Open
Abstract
PURPOSE Whole-brain high-resolution quantitative imaging is extremely encoding intensive, and its rapid and robust acquisition remains a challenge. Here we present a 3D MR fingerprinting (MRF) acquisition with a hybrid sliding-window (SW) and GRAPPA reconstruction strategy to obtain high-resolution T1, T2 and proton density (PD) maps with whole brain coverage in a clinically feasible timeframe. METHODS 3D MRF data were acquired using a highly under-sampled stack-of-spirals trajectory with a steady-state precession (FISP) sequence. For data reconstruction, kx-ky under-sampling was mitigated using SW combination along the temporal axis. Non-uniform fast Fourier transform (NUFFT) was then applied to create Cartesian k-space data that are fully-sampled in the in-plane direction, and Cartesian GRAPPA was performed to resolve kz under-sampling to create an alias-free SW dataset. T1, T2 and PD maps were then obtained using dictionary matching. RESULTS Phantom study demonstrated that the proposed 3D-MRF acquisition/reconstruction method is able to produce quantitative maps that are consistent with conventional quantification techniques. Retrospectively under-sampled in vivo acquisition revealed that SW + GRAPPA substantially improves quantification accuracy over the current state-of-the-art accelerated 3D MRF. Prospectively under-sampled in vivo study showed that whole brain T1, T2 and PD maps with 1 mm3 resolution could be obtained in 7.5 min. CONCLUSIONS 3D MRF stack-of-spirals acquisition with hybrid SW + GRAPPA reconstruction may provide a feasible approach for rapid, high-resolution quantitative whole-brain imaging.
Collapse
Affiliation(s)
- Congyu Liao
- Center for Brain Imaging Science and Technology, Key Laboratory for Biomedical Engineering of Ministry of Education, College of Biomedical Engineering and Instrumental Science, Zhejiang University, Hangzhou, Zhejiang, China; Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, MA, USA
| | - Berkin Bilgic
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, MA, USA; Department of Radiology, Harvard Medical School, Boston, MA, USA
| | - Mary Kate Manhard
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, MA, USA; Department of Radiology, Harvard Medical School, Boston, MA, USA
| | - Bo Zhao
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, MA, USA; Department of Radiology, Harvard Medical School, Boston, MA, USA
| | - Xiaozhi Cao
- Center for Brain Imaging Science and Technology, Key Laboratory for Biomedical Engineering of Ministry of Education, College of Biomedical Engineering and Instrumental Science, Zhejiang University, Hangzhou, Zhejiang, China
| | - Jianhui Zhong
- Center for Brain Imaging Science and Technology, Key Laboratory for Biomedical Engineering of Ministry of Education, College of Biomedical Engineering and Instrumental Science, Zhejiang University, Hangzhou, Zhejiang, China.
| | - Lawrence L Wald
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, MA, USA; Department of Radiology, Harvard Medical School, Boston, MA, USA
| | - Kawin Setsompop
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, MA, USA; Department of Radiology, Harvard Medical School, Boston, MA, USA
| |
Collapse
|
105
|
Panda A, Mehta BB, Coppo S, Jiang Y, Ma D, Seiberlich N, Griswold MA, Gulani V. Magnetic Resonance Fingerprinting-An Overview. CURRENT OPINION IN BIOMEDICAL ENGINEERING 2017; 3:56-66. [PMID: 29868647 DOI: 10.1016/j.cobme.2017.11.001] [Citation(s) in RCA: 61] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
Magnetic Resonance Fingerprinting (MRF) is a new approach to quantitative magnetic resonance imaging that allows simultaneous measurement of multiple tissue properties in a single, time-efficient acquisition. The ability to reproducibly and quantitatively measure tissue properties could enable more objective tissue diagnosis, comparisons of scans acquired at different locations and time points, longitudinal follow-up of individual patients and development of imaging biomarkers. This review provides a general overview of MRF technology, current preclinical and clinical applications and potential future directions. MRF has been initially evaluated in brain, prostate, liver, cardiac, musculoskeletal imaging, and measurement of perfusion and microvascular properties through MR vascular fingerprinting.
Collapse
Affiliation(s)
- Ananya Panda
- Department of Radiology, Case Western Reserve University, University Hospitals Cleveland Medical Center, Cleveland, Ohio, USA
| | - Bhairav B Mehta
- Department of Radiology, Case Western Reserve University, University Hospitals Cleveland Medical Center, Cleveland, Ohio, USA
| | - Simone Coppo
- Department of Radiology, Case Western Reserve University, University Hospitals Cleveland Medical Center, Cleveland, Ohio, USA
| | - Yun Jiang
- Department of Biomedical Engineering, Case Western Reserve University, University Hospitals Cleveland Medical Center, Cleveland, Ohio, USA
| | - Dan Ma
- Department of Radiology, Case Western Reserve University, University Hospitals Cleveland Medical Center, Cleveland, Ohio, USA
| | - Nicole Seiberlich
- Department of Radiology, Case Western Reserve University, University Hospitals Cleveland Medical Center, Cleveland, Ohio, USA.,Department of Biomedical Engineering, Case Western Reserve University, University Hospitals Cleveland Medical Center, Cleveland, Ohio, USA
| | - Mark A Griswold
- Department of Radiology, Case Western Reserve University, University Hospitals Cleveland Medical Center, Cleveland, Ohio, USA.,Department of Biomedical Engineering, Case Western Reserve University, University Hospitals Cleveland Medical Center, Cleveland, Ohio, USA
| | - Vikas Gulani
- Department of Radiology, Case Western Reserve University, University Hospitals Cleveland Medical Center, Cleveland, Ohio, USA.,Department of Biomedical Engineering, Case Western Reserve University, University Hospitals Cleveland Medical Center, Cleveland, Ohio, USA
| |
Collapse
|