1
|
Production of High Silicon-Doped Hydroxyapatite Thin Film Coatings via Magnetron Sputtering: Deposition, Characterisation, and In Vitro Biocompatibility. COATINGS 2020. [DOI: 10.3390/coatings10020190] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
In recent years, it has been found that small weight percent additions of silicon to HA can be used to enhance the initial response between bone tissue and HA. A large amount of research has been concerned with bulk materials, however, only recently has the attention moved to the use of these doped materials as coatings. This paper focusses on the development of a co-RF and pulsed DC magnetron sputtering methodology to produce a high percentage Si containing HA (SiHA) thin films (from 1.8 to 13.4 wt.%; one of the highest recorded in the literature to date). As deposited thin films were found to be amorphous, but crystallised at different annealing temperatures employed, dependent on silicon content, which also lowered surface energy profiles destabilising the films. X-ray photoelectron spectroscopy (XPS) was used to explore the structure of silicon within the films which were found to be in a polymeric (SiO2; Q4) state. However, after annealing, the films transformed to a SiO44−, Q0, state, indicating that silicon had substituted into the HA lattice at higher concentrations than previously reported. A loss of hydroxyl groups and the maintenance of a single-phase HA crystal structure further provided evidence for silicon substitution. Furthermore, a human osteoblast cell (HOB) model was used to explore the in vitro cellular response. The cells appeared to prefer the HA surfaces compared to SiHA surfaces, which was thought to be due to the higher solubility of SiHA surfaces inhibiting protein mediated cell attachment. The extent of this effect was found to be dependent on film crystallinity and silicon content.
Collapse
|
2
|
Stuart BW, Murray JW, Grant DM. Two step porosification of biomimetic thin-film hydroxyapatite/alpha-tri calcium phosphate coatings by pulsed electron beam irradiation. Sci Rep 2018; 8:14530. [PMID: 30266971 PMCID: PMC6162225 DOI: 10.1038/s41598-018-32612-x] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2018] [Accepted: 09/05/2018] [Indexed: 01/03/2023] Open
Abstract
Here we show a new and effective methodology for rapid/controllable porosification of thin-film ceramics, which may be applied in medical devices/electronics and membrane nano-filtration. Dense hydroxyapatite applied to Ti6Al4V by plasma-assisted PVD was electron-beam irradiated to induce flash melting/boiling. Deposited coatings contained amorphous and nano-crystalline/stoichiometric hydroxyapatite (~35 nm). Irradiation (voltages 13-29 kV) led to ablation (up to 45% mass loss) and average/maximum pore areas from (0.07-1.66)/(0.69-92.53) μm2, mimicking the human cortical bone. Vitrification above 1150 °C formed (~62-30 nm) crystallites of α-Tri Calcium Phosphate. Unique porosification resulted from irradiation-induced sub-surface boiling and limited thermal conductivity of hydroxyapatite, causing material to expand/explode through the more quickly solidified top surface. Commercially applicable, roughened Ti6Al4V exacerbated the heating and boiling explosion phenomenon in certain regions, producing an array of pore sizes. Scaffold-like morphologies were generated by interconnection of micron/sub-micron porosity, showing great potential for facile generation of a biomimetic surface treatment for osseointegration.
Collapse
Affiliation(s)
- Bryan W Stuart
- Advanced Materials Research Group, Faculty of Engineering, University of Nottingham, Nottingham, UK.
| | - James W Murray
- Advanced Materials Research Group, Faculty of Engineering, University of Nottingham, Nottingham, UK
| | - David M Grant
- Advanced Materials Research Group, Faculty of Engineering, University of Nottingham, Nottingham, UK.
| |
Collapse
|
3
|
Mostafa D, Aboushelib M. Bioactive-hybrid-zirconia implant surface for enhancing osseointegration: an in vivo study. Int J Implant Dent 2018; 4:20. [PMID: 29900480 PMCID: PMC5999599 DOI: 10.1186/s40729-018-0129-3] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2018] [Accepted: 04/23/2018] [Indexed: 11/12/2022] Open
Abstract
Background Zirconia is characterized by a hard, dense, and chemically inert surface which requires additional surface treatments in order to enhance osseointegration. The proposed hypothesis of the study was that combination of a nano-porous surface infiltrated with a bioactive material may enhance osseointegration of zirconia implants. Methods Custom-made zirconia implants (3.7 mm × 8 mm) were designed, milled, and sintered according to manufacturer recommendations. All implants received selective infiltration etching (SIE) technique to produce a nano-porous surface. Surface porosities were either filled with nano-hydroxy apatite particle- or platelet-rich plasma while uncoated surface served as a control (n = 12, α = 0.05). New surface properties were characterized with mercury porosimetry, XRD analysis, SEM, and EDX analysis. Implants were inserted in femur head of rabbits, and histomorphometric analysis was conducted after healing time to evaluate bone–implant contact percentage (BIC%). Results Selective infiltration etching produced a nano-porous surface with interconnected surface porosities. Mercury porosimetry revealed a significant reduction in total porosity percent after application of the two coating materials. XRD patterns detected hexagonal crystal structure of HA superimposed on the tetragonal crystal phase of zirconia. Histomorphometric analysis indicated a significantly higher (F = 14.6, P < 0.001) BIC% around HA–bioactive–hybrid surface (79.8 ± 3%) and PRP-coated surface (71 ± 6 %) compared to the control (49 ± 8%). Conclusions Bioactive–hybrid–zirconia implant surface enhanced osseointegration of zirconia implants.
Collapse
Affiliation(s)
- Dawlat Mostafa
- Dental Biomaterials, Faculty of Dentistry, Alexandria University, Champolion St., Azarita, Alexandria, Egypt
| | - Moustafa Aboushelib
- Dental Biomaterials, Faculty of Dentistry, Alexandria University, Champolion St., Azarita, Alexandria, Egypt.
| |
Collapse
|
4
|
Sun M, Chi G, Xu J, Tan Y, Xu J, Lv S, Xu Z, Xia Y, Li L, Li Y. Extracellular matrix stiffness controls osteogenic differentiation of mesenchymal stem cells mediated by integrin α5. Stem Cell Res Ther 2018; 9:52. [PMID: 29490668 PMCID: PMC5831741 DOI: 10.1186/s13287-018-0798-0] [Citation(s) in RCA: 115] [Impact Index Per Article: 19.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2017] [Revised: 01/18/2018] [Accepted: 02/05/2018] [Indexed: 01/12/2023] Open
Abstract
Background Human mesenchymal stem cell (hMSC) differentiation into osteoblasts has important clinical significance in treating bone injury, and the stiffness of the extracellular matrix (ECM) has been shown to be an important regulatory factor for hMSC differentiation. The aim of this study was to further delineate how matrix stiffness affects intracellular signaling through integrin α5/β1, FAK, and Wnt signaling, subsequently regulating the osteogenic phenotype of hMSCs. Methods hMSCs were cultured on tunable polyacrylamide hydrogels coated with fibronectin with stiffness corresponding to a Young’s modulus of 13–16 kPa and 62–68 kPa. After hMSCs were cultured on gels for 1 week, gene expression of alpha-1typeIcollagen, BGLAP, and RUNX2 were evaluated by real-time PCR. After hMSCs were cultured on gels for 24 h, signaling molecules relating to integrin α5 (FAK, ERK, p-ERK, Akt, p-Akt, GSK-3β, p-GSK-3β, and β-catenin) were evaluated by western blot analysis. Results Osteogenic differentiation was increased on 62–68 kPa ECM, as evidenced by alpha-1 type I collagen, BGLAP, and RUNX2 gene expression, calcium deposition, and ALP staining. In the process of differentiation, gene and protein expression of integrin α5/β1 increased, together with protein expression of the downstream signaling molecules FAK, p-ERK, p-Akt, GSK-3β, p-GSK-3β, and β-catenin, indicating that these molecules can affect the osteogenic differentiation of hMSCs. An antibody blocking integrin α5 suppressed the stiffness-induced expression of all osteoblast markers examined. In particular, alpha-1 type I collagen, RUNX2, and BGLAP were significantly downregulated, indicating that integrin α5 regulates hMSC osteogenic differentiation. Downstream expression of FAK, ERK, p-ERK, and β-catenin protein was unchanged, whereas Akt, p-Akt, GSK-3β, and p-GSK-3β were upregulated. Moreover, expression of Akt and p-Akt was upregulated with anti-integrin α5 antibody, but no difference was observed for FAK, ERK, and p-ERK between the with or without anti-integrin α5 antibody groups. At the same time, expression of GSK-3β and p-GSK-3β was upregulated and β-catenin levels showed no difference between the groups with or without anti-integrin α5 antibody. Since Akt, p-Akt, GSK-3β, and p-GSK-3β displayed the same changes between the groups with or without anti-integrin α5 antibody, we then detected the links among them. Expression of p-Akt and p-GSK-3β was reduced effectively in the presence of the Akt inhibitor Triciribine. However, Akt, GSK-3β, and β-catenin were unchanged. These results suggested that expression of p-GSK-3β was regulated by p-Akt on 62–68 kPa ECM. Conclusions Taken together, our results provide evidence that matrix stiffness (62–68 kPa) affects the osteogenic outcome of hMSCs through mechanotransduction events that are mediated by integrin α5. Electronic supplementary material The online version of this article (10.1186/s13287-018-0798-0) contains supplementary material, which is available to authorized users.
Collapse
Affiliation(s)
- Meiyu Sun
- The Key Laboratory of Pathobiology, Ministry of Education, Norman Bethune College of Medicine, Jilin University, Changchun, 130021, People's Republic of China
| | - Guangfan Chi
- The Key Laboratory of Pathobiology, Ministry of Education, Norman Bethune College of Medicine, Jilin University, Changchun, 130021, People's Republic of China
| | - Juanjuan Xu
- The Key Laboratory of Pathobiology, Ministry of Education, Norman Bethune College of Medicine, Jilin University, Changchun, 130021, People's Republic of China
| | - Ye Tan
- The Key Laboratory of Pathobiology, Ministry of Education, Norman Bethune College of Medicine, Jilin University, Changchun, 130021, People's Republic of China
| | - Jiayi Xu
- The Key Laboratory of Pathobiology, Ministry of Education, Norman Bethune College of Medicine, Jilin University, Changchun, 130021, People's Republic of China
| | - Shuang Lv
- The Key Laboratory of Pathobiology, Ministry of Education, Norman Bethune College of Medicine, Jilin University, Changchun, 130021, People's Republic of China
| | - Ziran Xu
- The Key Laboratory of Pathobiology, Ministry of Education, Norman Bethune College of Medicine, Jilin University, Changchun, 130021, People's Republic of China
| | - Yuhan Xia
- The Key Laboratory of Pathobiology, Ministry of Education, Norman Bethune College of Medicine, Jilin University, Changchun, 130021, People's Republic of China
| | - Lisha Li
- The Key Laboratory of Pathobiology, Ministry of Education, Norman Bethune College of Medicine, Jilin University, Changchun, 130021, People's Republic of China.
| | - Yulin Li
- The Key Laboratory of Pathobiology, Ministry of Education, Norman Bethune College of Medicine, Jilin University, Changchun, 130021, People's Republic of China.
| |
Collapse
|
5
|
A Novel Method to Improve the Anticancer Activity of Natural-Based Hydroxyapatite against the Liver Cancer Cell Line HepG2 Using Mesoporous Magnesia as a Micro-Carrier. Molecules 2017; 22:molecules22121947. [PMID: 29186752 PMCID: PMC6149827 DOI: 10.3390/molecules22121947] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2017] [Revised: 10/30/2017] [Accepted: 11/08/2017] [Indexed: 01/22/2023] Open
Abstract
Micro-carriers are the best known vehicles to transport different kinds of drugs to achieve high impact. In this study, mesoporous magnesium oxide has been harnessed as a micro-carrier to encapsulate the anticancer candidate drug natural-based cubic hydroxyapatite (HAP). HAP@MgO composites with different HAP loading (0-60 wt %), were prepared by a hydrothermal treatment method using triethanol amine as a template. The characterization of the prepared composites were achieved by using XRD, Raman spectroscopy, FTIR and SEM. Characterization data confirm the formation of sphere-like structures of MgO containing HAP particles. It was observed that the size of the spheres increased with HAP loading up to 40 wt %, then collapsed. Furthermore, the anticancer property of the prepared composites was evaluated against the HepG2 liver cancer cell line. The HAP@MgO composites exhibited higher activity than neat MgO or HAP. The 20 wt % of HAP was the optimum loading to control cell proliferation by inducing apoptosis. Apoptosis was determined by typical apoptotic bodies produced by the cell membrane.
Collapse
|
6
|
Eliaz N, Metoki N. Calcium Phosphate Bioceramics: A Review of Their History, Structure, Properties, Coating Technologies and Biomedical Applications. MATERIALS (BASEL, SWITZERLAND) 2017; 10:E334. [PMID: 28772697 PMCID: PMC5506916 DOI: 10.3390/ma10040334] [Citation(s) in RCA: 393] [Impact Index Per Article: 56.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/11/2017] [Revised: 03/15/2017] [Accepted: 03/22/2017] [Indexed: 02/06/2023]
Abstract
Calcium phosphate (CaP) bioceramics are widely used in the field of bone regeneration, both in orthopedics and in dentistry, due to their good biocompatibility, osseointegration and osteoconduction. The aim of this article is to review the history, structure, properties and clinical applications of these materials, whether they are in the form of bone cements, paste, scaffolds, or coatings. Major analytical techniques for characterization of CaPs, in vitro and in vivo tests, and the requirements of the US Food and Drug Administration (FDA) and international standards from CaP coatings on orthopedic and dental endosseous implants, are also summarized, along with the possible effect of sterilization on these materials. CaP coating technologies are summarized, with a focus on electrochemical processes. Theories on the formation of transient precursor phases in biomineralization, the dissolution and reprecipitation as bone of CaPs are discussed. A wide variety of CaPs are presented, from the individual phases to nano-CaP, biphasic and triphasic CaP formulations, composite CaP coatings and cements, functionally graded materials (FGMs), and antibacterial CaPs. We conclude by foreseeing the future of CaPs.
Collapse
Affiliation(s)
- Noam Eliaz
- Biomaterials and Corrosion Lab, Department of Materials Science and Engineering, Tel-Aviv University, Ramat Aviv 6997801, Israel.
| | - Noah Metoki
- Biomaterials and Corrosion Lab, Department of Materials Science and Engineering, Tel-Aviv University, Ramat Aviv 6997801, Israel.
| |
Collapse
|
7
|
Tachaboonyakiat W, Ogomi D, Serizawa T, Akashi M. Evaluation of Cell Adhesion and Proliferation on a Novel Tissue Engineering Scaffold Containing Chitosan and Hydroxyapatite. J BIOACT COMPAT POL 2016. [DOI: 10.1177/0883911506070441] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
Abstract
Porous chitosan-hxdroxyapatite hybrids were developed by partial enzymatic degradation [14] of the chitin/chitosan surface using chitosanase and lysozyme. This article evaluates the influence of chitosan and hydroxyapatite components, substrate roughness, stability, as well as surface porosity produced by enzymatic hydrolysis to cell adhesion and proliferation. L929 mouse fibroblastic lung cells were cultured on enzymatic degraded porous chitosan-hydroxyapatite hybrids. The presence of hydroxyapatite and porosity produced by partial lysozyme hydrolysis enhance cell proliferation. Besides, cell adhesion and proliferation are primarily dependent on substrate roughness and stability.
Collapse
Affiliation(s)
- Wanpen Tachaboonyakiat
- Department of Materials Science, Faculty of Science, Chulalongkorn University, Phyathai, Bangkok 10330, Thailand
| | - Daisuke Ogomi
- Nitto Denko Corporation, 455-6 Hongo, Minogo, Onomichi, Hiroshima 722-0212, Japan
| | - Takeshi Serizawa
- Research Center for Advanced Science and Technology, The University of Tokyo, 4-6-1 Komaba, Meguro-ku, Tokyo 153-8904, Japan
| | - Mitsuru Akashi
- Department of Applied Chemistry, Graduate School of Engineering, Osaka University, Yamada-oka, Suita 565-0871, Japan
| |
Collapse
|
8
|
Rana D, Ramasamy K, Leena M, Jiménez C, Campos J, Ibarra P, Haidar ZS, Ramalingam M. Surface functionalization of nanobiomaterials for application in stem cell culture, tissue engineering, and regenerative medicine. Biotechnol Prog 2016; 32:554-67. [DOI: 10.1002/btpr.2262] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2015] [Revised: 03/16/2016] [Indexed: 11/11/2022]
Affiliation(s)
- Deepti Rana
- Centre for Stem Cell Research (CSCR); A Unit of Institute for Stem Cell Biology and Regenerative Medicine-Bengaluru, Stem Cell Nanotechnology Lab, Christian Medical College Campus; Vellore 632002 India
| | - Keerthana Ramasamy
- Centre for Stem Cell Research (CSCR); A Unit of Institute for Stem Cell Biology and Regenerative Medicine-Bengaluru, Stem Cell Nanotechnology Lab, Christian Medical College Campus; Vellore 632002 India
| | - Maria Leena
- Dept. of Nanoscience and Technology; Karunya University; Coimbatore 641114 India
| | - Constanza Jiménez
- BioMAT'X, Facultad De Odontología; Universidad De Los Andes; Mons. Álvaro Del Portillo Santiago 12.455 Chile
- Centro De Investigación Biomédica (CIB), Facultad De Medicina; Universidad De Los Andes; Mons. Álvaro Del Portillo Santiago 12.455 Chile
| | - Javier Campos
- BioMAT'X, Facultad De Odontología; Universidad De Los Andes; Mons. Álvaro Del Portillo Santiago 12.455 Chile
- Plan De Mejoramiento Institucional (PMI) En Innovación-I+D+I, Universidad De Los Andes; Santiago 12.455 Chile
| | - Paula Ibarra
- BioMAT'X, Facultad De Odontología; Universidad De Los Andes; Mons. Álvaro Del Portillo Santiago 12.455 Chile
- Plan De Mejoramiento Institucional (PMI) En Innovación-I+D+I, Universidad De Los Andes; Santiago 12.455 Chile
| | - Ziyad S. Haidar
- BioMAT'X, Facultad De Odontología; Universidad De Los Andes; Mons. Álvaro Del Portillo Santiago 12.455 Chile
- Plan De Mejoramiento Institucional (PMI) En Innovación-I+D+I, Universidad De Los Andes; Santiago 12.455 Chile
| | - Murugan Ramalingam
- Centre for Stem Cell Research (CSCR); A Unit of Institute for Stem Cell Biology and Regenerative Medicine-Bengaluru, Stem Cell Nanotechnology Lab, Christian Medical College Campus; Vellore 632002 India
- WPI-Advanced Institute for Materials Research, Tohoku University; Sendai 980-8577 Japan
| |
Collapse
|
9
|
Qiu ZY, Chen C, Wang XM, Lee IS. Advances in the surface modification techniques of bone-related implants for last 10 years. Regen Biomater 2014; 1:67-79. [PMID: 26816626 PMCID: PMC4668999 DOI: 10.1093/rb/rbu007] [Citation(s) in RCA: 53] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2014] [Revised: 08/22/2014] [Accepted: 08/23/2014] [Indexed: 12/20/2022] Open
Abstract
At the time of implanting bone-related implants into human body, a variety of biological responses to the material surface occur with respect to surface chemistry and physical state. The commonly used biomaterials (e.g. titanium and its alloy, Co-Cr alloy, stainless steel, polyetheretherketone, ultra-high molecular weight polyethylene and various calcium phosphates) have many drawbacks such as lack of biocompatibility and improper mechanical properties. As surface modification is very promising technology to overcome such problems, a variety of surface modification techniques have been being investigated. This review paper covers recent advances in surface modification techniques of bone-related materials including physicochemical coating, radiation grafting, plasma surface engineering, ion beam processing and surface patterning techniques. The contents are organized with different types of techniques to applicable materials, and typical examples are also described.
Collapse
Affiliation(s)
- Zhi-Ye Qiu
- Institute for Regenerative Medicine and Biomimetic Materials, School of Materials Science and Engineering, Tsinghua University, Beijing 100084, China, Beijing Allgens Medical Science and Technology Co., Ltd, Beijing 100176, China, Bio-X Center, School of Life Science, Zhejiang Sci-Tech University, Hangzhou 310018, China, and Institute of Natural Sciences, Yonsei University, Seoul 120-749, Korea
| | - Cen Chen
- Institute for Regenerative Medicine and Biomimetic Materials, School of Materials Science and Engineering, Tsinghua University, Beijing 100084, China, Beijing Allgens Medical Science and Technology Co., Ltd, Beijing 100176, China, Bio-X Center, School of Life Science, Zhejiang Sci-Tech University, Hangzhou 310018, China, and Institute of Natural Sciences, Yonsei University, Seoul 120-749, Korea
| | - Xiu-Mei Wang
- Institute for Regenerative Medicine and Biomimetic Materials, School of Materials Science and Engineering, Tsinghua University, Beijing 100084, China, Beijing Allgens Medical Science and Technology Co., Ltd, Beijing 100176, China, Bio-X Center, School of Life Science, Zhejiang Sci-Tech University, Hangzhou 310018, China, and Institute of Natural Sciences, Yonsei University, Seoul 120-749, Korea
| | - In-Seop Lee
- Institute for Regenerative Medicine and Biomimetic Materials, School of Materials Science and Engineering, Tsinghua University, Beijing 100084, China, Beijing Allgens Medical Science and Technology Co., Ltd, Beijing 100176, China, Bio-X Center, School of Life Science, Zhejiang Sci-Tech University, Hangzhou 310018, China, and Institute of Natural Sciences, Yonsei University, Seoul 120-749, Korea
| |
Collapse
|
10
|
Surmenev RA, Surmeneva MA, Ivanova AA. Significance of calcium phosphate coatings for the enhancement of new bone osteogenesis--a review. Acta Biomater 2014; 10:557-79. [PMID: 24211734 DOI: 10.1016/j.actbio.2013.10.036] [Citation(s) in RCA: 317] [Impact Index Per Article: 31.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2013] [Revised: 10/25/2013] [Accepted: 10/29/2013] [Indexed: 12/15/2022]
Abstract
A systematic analysis of results available from in vitro, in vivo and clinical trials on the effects of biocompatible calcium phosphate (CaP) coatings is presented. An overview of the most frequently used methods to prepare CaP-based coatings was conducted. Dense, homogeneous, highly adherent and biocompatible CaP or hybrid organic/inorganic CaP coatings with tailored properties can be deposited. It has been demonstrated that CaP coatings have a significant effect on the bone regeneration process. In vitro experiments using different cells (e.g. SaOS-2, human mesenchymal stem cells and osteoblast-like cells) have revealed that CaP coatings enhance cellular adhesion, proliferation and differentiation to promote bone regeneration. However, in vivo, the exact mechanism of osteogenesis in response to CaP coatings is unclear; indeed, there are conflicting reports of the effectiveness of CaP coatings, with results ranging from highly effective to no significant or even negative effects. This review therefore highlights progress in CaP coatings for orthopaedic implants and discusses the future research and use of these devices. Currently, an exciting area of research is in bioactive hybrid composite CaP-based coatings containing both inorganic (CaP coating) and organic (collagen, bone morphogenetic proteins, arginylglycylaspartic acid etc.) components with the aim of promoting tissue ingrowth and vascularization. Further investigations are necessary to reveal the relative influences of implant design, surgical procedure, and coating characteristics (thickness, structure, topography, porosity, wettability etc.) on the long-term clinical effects of hybrid CaP coatings. In addition to commercially available plasma spraying, other effective routes for the fabrication of hybrid CaP coatings for clinical use still need to be determined and current progress is discussed.
Collapse
Affiliation(s)
- Roman A Surmenev
- Department of Theoretical and Experimental Physics, National Research Tomsk Polytechnic University, 634050 Tomsk, Russia; Fraunhofer Institute for Interfacial Engineering and Biotechnology IGB, 70569 Stuttgart, Germany.
| | - Maria A Surmeneva
- Department of Theoretical and Experimental Physics, National Research Tomsk Polytechnic University, 634050 Tomsk, Russia
| | - Anna A Ivanova
- Department of Theoretical and Experimental Physics, National Research Tomsk Polytechnic University, 634050 Tomsk, Russia
| |
Collapse
|
11
|
Magnesium coated bioresorbable phosphate glass fibres: investigation of the interface between fibre and polyester matrices. BIOMED RESEARCH INTERNATIONAL 2013; 2013:735981. [PMID: 24066297 PMCID: PMC3771308 DOI: 10.1155/2013/735981] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/19/2013] [Revised: 07/22/2013] [Accepted: 07/22/2013] [Indexed: 11/18/2022]
Abstract
Bioresorbable phosphate glass fibre reinforced polyester composites have been investigated as replacement for some traditional metallic orthopaedic implants, such as bone fracture fixation plates. However, composites tested revealed loss of the interfacial integrity after immersion within aqueous media which resulted in rapid loss of mechanical properties. Physical modification of fibres to change fibre surface morphology has been shown to be an effective method to improve fibre and matrix adhesion in composites. In this study, biodegradable magnesium which would gradually degrade to Mg(2+) in the human body was deposited via magnetron sputtering onto bioresorbable phosphate glass fibres to obtain roughened fibre surfaces. Fibre surface morphology after coating was observed using scanning electron microscope (SEM). The roughness profile and crystalline texture of the coatings were determined via atomic force microscope (AFM) and X-ray diffraction (XRD) analysis, respectively. The roughness of the coatings was seen to increase from 40 ± 1 nm to 80 ± 1 nm. The mechanical properties (tensile strength and modulus) of fibre with coatings decreased with increased magnesium coating thickness.
Collapse
|
12
|
Mutreja I, Kumar D, Boyd AR, Meenan BJ. Titania nanotube porosity controls dissolution rate of sputter deposited calcium phosphate (CaP) thin film coatings. RSC Adv 2013. [DOI: 10.1039/c3ra40898a] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023] Open
|
13
|
|
14
|
Dorozhkin SV. Calcium orthophosphate coatings, films and layers. Prog Biomater 2012; 1:1. [PMID: 29470670 PMCID: PMC5120666 DOI: 10.1186/2194-0517-1-1] [Citation(s) in RCA: 47] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2012] [Accepted: 06/14/2012] [Indexed: 11/16/2022] Open
Abstract
In surgical disciplines, where bones have to be repaired, augmented or improved, bone substitutes are essential. Therefore, an interest has dramatically increased in application of synthetic bone grafts. As various interactions among cells, surrounding tissues and implanted biomaterials always occur at the interfaces, the surface properties of the implants are of the paramount importance in determining both the biological response to implants and the material response to the physiological conditions. Hence, a surface engineering is aimed to modify both the biomaterials, themselves, and biological responses through introducing desirable changes to the surface properties of the implants but still maintaining their bulk mechanical properties. To fulfill these requirements, a special class of artificial bone grafts has been introduced in 1976. It is composed of various mechanically stable (therefore, suitable for load bearing applications) biomaterials and/or bio-devices with calcium orthophosphate coatings, films and layers on their surfaces to both improve interactions with the surrounding tissues and provide an adequate bonding to bones. Many production techniques of calcium orthophosphate coatings, films and layers have been already invented and new promising techniques are continuously investigated. These specialized coatings, films and layers used to improve the surface properties of various types of artificial implants are the topic of this review.
Collapse
|
15
|
Rajesh P, Muraleedharan CV, Komath M, Varma H. Laser surface modification of titanium substrate for pulsed laser deposition of highly adherent hydroxyapatite. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 2011; 22:1671-1679. [PMID: 21598038 DOI: 10.1007/s10856-011-4342-3] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/14/2011] [Accepted: 05/09/2011] [Indexed: 05/30/2023]
Abstract
Biomedical implant devices made out of titanium and its alloys are benefited by a modified surface or a bioactive coating to enhance bone bonding ability and to function effectively in vivo for the intended period of time. In this respect hydroxyapatite coating developed through pulsed laser deposition is a promising approach. Since the success of the bioactive ceramic coated implant depends mainly on the substrate-coating strength; an attempt has been made to produce micro patterned surface structure on titanium substrate for adherent hydroxyapatite coating. A pulsed Nd-YAG laser beam (355 nm) with 10 Hz repetition rate was used for surface treatment of titanium as well as hydroxyapatite deposition. The unfocussed laser beam was used to modify the substrate surface with 500-18,000 laser pulses while keeping the polished substrate in water. Hydroxyapatite deposition was done in a vacuum deposition chamber at 400 °C with the focused laser beam under 1 × 10⁻³ mbar oxygen pressure. Deposits were analyzed to understand the physico-chemical, morphological and mechanical characteristics. The obtained substrate and coating surface morphology indicates that laser treatment method can provide controlled micro-topography. Scratch test analysis and microindentation hardness values of coating on laser treated substrate indicate higher mechanical adhesion with respect to coatings on untreated substrates.
Collapse
Affiliation(s)
- P Rajesh
- Bioceramics Laboratory, Biomedical Technology Wing, Sree Chitra Tirunal Institute for Medical Sciences and Technology (SCTIMST), Trivandrum 695012, Kerala, India
| | | | | | | |
Collapse
|
16
|
Boyd AR, Burke GA, Duffy H, Holmberg M, O' Kane C, Meenan BJ, Kingshott P. Sputter deposited bioceramic coatings: surface characterisation and initial protein adsorption studies using surface-MALDI-MS. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 2011; 22:71-84. [PMID: 21104194 DOI: 10.1007/s10856-010-4180-8] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/30/2009] [Accepted: 10/25/2010] [Indexed: 05/30/2023]
Abstract
Protein adsorption onto calcium phosphate (Ca-P) bioceramics utilised in hard tissue implant applications has been highlighted as one of the key events that influences the subsequent biological response, in vivo. This work reports on the use of surface-matrix assisted laser desorption ionisation mass spectrometry (Surface-MALDI-MS) as a technique for the direct detection of foetal bovine serum (FBS) proteins adsorbed to hybrid calcium phosphate/titanium dioxide surfaces produced by a novel radio frequency (RF) magnetron sputtering method incorporating in situ annealing between 500°C and 700°C during deposition. XRD and XPS analysis indicated that the coatings produced at 700°C were hybrid in nature, with the presence of Ca-P and titanium dioxide clearly observed in the outer surface layer. In addition to this, the Ca/P ratio was seen to increase with increasing annealing temperature, with values of between 2.0 and 2.26 obtained for the 700°C samples. After exposure to FBS solution, surface-MALDI-MS indicated that there were significant differences in the protein patterns as shown by unique peaks detected at masses below 23.1 kDa for the different surfaces. These adsorbates were assigned to a combination of growth factors and lipoproteins present in serum. From the data obtained here it is evident that surface-MALDI-MS has significant utility as a tool for studying the dynamic nature of protein adsorption onto the surfaces of bioceramic coatings, which most likely plays a significant role in subsequent bioactivity of the materials.
Collapse
Affiliation(s)
- A R Boyd
- Nanotechnology and Integrated Bioengineering Centre (NIBEC), University of Ulster at Jordanstown, Newtownabbey, Co, Antrim, Northern Ireland, UK.
| | | | | | | | | | | | | |
Collapse
|
17
|
Sima F, Ristoscu C, Caiteanu D, Mihailescu CN, Stefan N, Mihailescu IN, Prodan G, Ciupina V, Palcevskis E, Krastins J, Sima LE, Petrescu SM. Biocompatibility and bioactivity enhancement of Ce stabilized ZrO(2) doped HA coatings by controlled porosity change of Al(2) O(3) substrates. J Biomed Mater Res B Appl Biomater 2010; 96:218-24. [PMID: 21210500 DOI: 10.1002/jbm.b.31755] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2009] [Revised: 07/27/2010] [Accepted: 08/31/2010] [Indexed: 11/10/2022]
Abstract
Al(2) O(3) substrates with controlled porosity were manufactured from nanosized powders obtained by plasma processing. It was observed that when increasing the sintering temperature the overall porosity was decreasing, but the pores got larger. In a second step, Ce stabilized ZrO(2) doped hydroxyapatite coatings were pulsed laser deposited onto the Al(2) O(3) substrates. It was shown that the surface morphology, consisting of aggregates and particulates in micrometric range, was altered by the substrate porosity and interface properties, respectively. TEM studies evidenced that Ce stabilized ZrO(2) doped HA particulates ranged from 10 to 50 nm, strongly depending on the Al(2) O(3) porosity. The coatings consisted of HA nanocrystals embedded in an amorphous matrix quite similar to the bone structure. These findings were congruent with the increased biocompatibility and bioactivity of these layers confirmed by enhanced growing and proliferation of human mesenchymal stem cells.
Collapse
Affiliation(s)
- Felix Sima
- Laser Department, National Institute for Lasers, Plasma, and Radiation Physics, Magurele, Ilfov, Romania
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
18
|
Functional Coatings or Films for Hard-Tissue Applications. MATERIALS 2010; 3:3994-4050. [PMID: 28883319 PMCID: PMC5445792 DOI: 10.3390/ma3073994] [Citation(s) in RCA: 115] [Impact Index Per Article: 8.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/04/2010] [Revised: 06/23/2010] [Accepted: 07/07/2010] [Indexed: 12/21/2022]
Abstract
Metallic biomaterials like stainless steel, Co-based alloy, Ti and its alloys are widely used as artificial hip joints, bone plates and dental implants due to their excellent mechanical properties and endurance. However, there are some surface-originated problems associated with the metallic implants: corrosion and wear in biological environments resulting in ions release and formation of wear debris; poor implant fixation resulting from lack of osteoconductivity and osteoinductivity; implant-associated infections due to the bacterial adhesion and colonization at the implantation site. For overcoming these surface-originated problems, a variety of surface modification techniques have been used on metallic implants, including chemical treatments, physical methods and biological methods. This review surveys coatings that serve to provide properties of anti-corrosion and anti-wear, biocompatibility and bioactivity, and antibacterial activity.
Collapse
|
19
|
Sygnatowicz M, Tiwari A. Controlled synthesis of hydroxyapatite-based coatings for biomedical application. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2009. [DOI: 10.1016/j.msec.2008.08.036] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
20
|
Jarmar T, Palmquist A, Brånemark R, Hermansson L, Engqvist H, Thomsen P. Characterization of the surface properties of commercially available dental implants using scanning electron microscopy, focused ion beam, and high-resolution transmission electron microscopy. Clin Implant Dent Relat Res 2008; 10:11-22. [PMID: 18254738 DOI: 10.1111/j.1708-8208.2007.00056.x] [Citation(s) in RCA: 65] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
Abstract
BACKGROUND Since osseointegration of the respective implant is claimed by all manufacturing companies, it is obvious that not just one specific surface profile including the chemistry controls bone apposition. PURPOSE The purpose was to identify and separate out a particular set of surface features of the implant surfaces that can contribute as factors in the osseointegration process. MATERIAL AND METHODS The surface properties of several commercially available dental implants were extensively studied using profilometry, scanning electron microscopy, and transmission electron microscopy. Ultrathin sections prepared with focused ion beam microscopy (FIB) provided microstructural and chemical data which have not previously been communicated. The implants were the Nobel Biocare TiUnite (Nobel Biocare AB, Göteborg, Sweden), Nobel Biocare Steri-Oss HA-coated (Nobel Biocare AB, Yorba Linda, CA, USA), Astra-Tech OsseoSpeed (Astra Tech AB, Mölndal, Sweden), Straumann SLA (Straumann AG, Waldenburg, Switzerland), and the Brånemark Integration Original Fixture implant (Brånemark Integration, Göteborg, Sweden). RESULTS It was found that their surface properties had differences. The surfaces were covered with crystalline TiO(2) (both anatase and rutile), amorphous titanium oxide, phosphorus doped amorphous titanium oxide, fluorine, titanium hydride, and hydroxyapatite, respectively. CONCLUSION This indicates that the provision of osseointegration is not exclusively linked to a particular set of surface features if the implant surface character is a major factor in that process. The studied methodology provides an effective tool to also analyze the interface between implant and surrounding bone. This would be a natural next step in understanding the ultrastructure of the interface between bone and implants.
Collapse
Affiliation(s)
- Tobias Jarmar
- Department of Engineering Sciences, Uppsala University, Box 534, SE-751 21 Uppsala, Sweden.
| | | | | | | | | | | |
Collapse
|
21
|
Anabtawi M, Beck P, Lemons J. Biocompatibility testing of simulated total joint arthoplasty articulation debris. J Biomed Mater Res B Appl Biomater 2008; 84:478-85. [PMID: 17879385 DOI: 10.1002/jbm.b.30894] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Surface characterization was performed to evaluate the surface condition of an uncoated cobalt alloy disc (control), and discs with medium and thick boron coatings for total joint articulating surfaces. Discs were characterized by scanning electron microscopy before and after dissolution studies. Chemical analyses of elemental transfer to the solution were assessed to evaluate the surface stability of the new coating. An in vivo biocompatibility study for particulates [of boron (B), titanium alloy (Ti), cobalt alloy (Co), and combinations of B + Ti and B + Co] was performed using a rat air pouch model. The inflammatory reactions to particulates were evaluated histologically and histochemically. No physical alteration was seen in the discs after the dissolution studies, and the elemental transfer to the dissolution solution was minimal. The cytokines, tumor necrosis factor (TNFalpha), and histology results from these simulated debris showed similar and moderate level responses magnitudes for the boron and mixtures and the primary alloy particulates. The conclusion from this initial study was that assessments of the coated discs showed physical properties similar to control. Also results from the in vivo studies of simulated wear debris from boron coatings on titanium and cobalt alloys demonstrated biocompatibility profiles that were mild to moderate and similar to prior analyses of wear debris products in synovial pouch models.
Collapse
Affiliation(s)
- Mona Anabtawi
- Department of Prosthodontics, School of Dentistry, University of Alabama at Birmingham, Birmingham, Alabama 35294-0007, USA.
| | | | | |
Collapse
|
22
|
Sputter deposition of calcium phosphate/titanium dioxide hybrid thin films. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2008. [DOI: 10.1016/j.msec.2006.12.004] [Citation(s) in RCA: 40] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|
23
|
Boyd AR, Burke GA, Duffy H, Cairns ML, O'Hare P, Meenan BJ. Characterisation of calcium phosphate/titanium dioxide hybrid coatings. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 2008; 19:485-98. [PMID: 17607520 DOI: 10.1007/s10856-006-0031-z] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/07/2006] [Accepted: 10/19/2006] [Indexed: 05/16/2023]
Abstract
The role of titanium dioxide (TiO2) as a means to engender enhanced stability into calcium phosphate (Ca-P) coatings has been well recognised. Several different methods have been used to create such Ca-P/TiO2 hybrid layers on a range of substrates. This paper reports the properties of a Ca-P/TiO2 system created by the sputter deposition of hydroxyapatite onto a titanium surface and the subsequent thermal diffusion of TiO2 through the porous Ca-P layer. The role of temperature in determining the surface contribution from TiO2 has been determined. Coatings annealed up to 600 degrees C did not exhibit any hybrid nature in the uppermost surface, however the coatings annealed to 700 degrees C did show the presence of both HA and rutile TiO2. The surfaces annealed to 800 degrees C were predominantly rutile TiO2. It was also observed that the Ca/P ratio decreased with increasing annealing temperature and that the coating annealed to 700 degrees C had a value of 1.82 +/- 0.07, which was closest to stoichiometric HA. Furthermore, the coatings that were annealed to 700 degrees C displayed a Ca-P/TiO2 hybrid nature, specifically in their uppermost surface and supported the growth and proliferation of osteoblast-like cells more readily when compared to the HA coatings or the rutile TiO2 surfaces.
Collapse
Affiliation(s)
- A R Boyd
- Northern Ireland Bioengineering Centre/Nanotechnology and Advanced Materials Research Institute, University of Ulster at Jordanstown, Shore Road, Room 25A18, Newtownabbey, Co. Antrim, Northern Ireland, UK.
| | | | | | | | | | | |
Collapse
|
24
|
Narayanan R, Seshadri SK, Kwon TY, Kim KH. Calcium phosphate-based coatings on titanium and its alloys. J Biomed Mater Res B Appl Biomater 2008; 85:279-99. [PMID: 17853421 DOI: 10.1002/jbm.b.30932] [Citation(s) in RCA: 132] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Use of titanium as biomaterial is possible because of its very favorable biocompatibility with living tissue. Titanium implants having calcium phosphate coatings on their surface show good fixation to the bone. This review covers briefly the requirements of typical biomaterials and narrowly focuses on the works on titanium. Calcium phosphate ceramics for use in implants are introduced and various methods of producing calcium phosphate coating on titanium substrates are elaborated. Advantages and disadvantages of each type of coating from the view point of process simplicity, cost-effectiveness, stability of the coatings, coating integration with the bone, cell behavior, and so forth are highlighted. Taking into account all these factors, the efficient method(s) of producing these coatings are indicated finally.
Collapse
Affiliation(s)
- R Narayanan
- Department of Metallurgical and Materials Engineering, Indian Institute of Technology Madras, Chennai 600036, India.
| | | | | | | |
Collapse
|
25
|
Pulsed laser deposition of hydroxyapatite thin films. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2007. [DOI: 10.1016/j.msec.2006.05.025] [Citation(s) in RCA: 98] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
|
26
|
Pramatarova L, Pecheva E, Krastev V, Riesz F. Ion implantation modified stainless steel as a substrate for hydroxyapatite deposition. Part I. Surface modification and characterization. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 2007; 18:435-40. [PMID: 17334693 DOI: 10.1007/s10856-007-2002-4] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/11/2005] [Accepted: 10/24/2005] [Indexed: 05/14/2023]
Abstract
Material surfaces play critical role in biology and medicine since most biological reactions occur on surfaces and interfaces. There are many examples showing that the surface properties of the materials control and are directly involved in biological reactions and processes in-vitro like blood compatibility, protein absorption, cell development, etc. The rules that govern the diversity of biological surface phenomenon are fundamental physical laws. Stainless steel doped with Cr, Ni and Mo is widely used material in medicine and dentistry due to its excellent corrosion resistance and mechanical properties. The interest in this material has stimulated extensive studies on improving its bone-bonding properties. This paper describes the surface modification of Cr-Ni stainless steel (AISI 316) by a whole surface sequential implantation of Ca and P ions (the basic ions of hydroxyapatite). Three groups of stainless steel samples are prepared: (i) ion-implanted, (ii) ion-implanted and thermally treated at 600( composite function)C in air for 1 h and (iii) initials. The surface chemistry and topography before and after the surface modification are characterized by X-ray photoelectron spectroscopy, Auger electron spectroscopy, magic mirror method, atomic force microscopy and contact angle measurements.
Collapse
Affiliation(s)
- L Pramatarova
- Institute of Solid State Physics, Bulgarian Academy of Sciences, Sofia, Bulgaria
| | | | | | | |
Collapse
|
27
|
Pessková V, Kubies D, Hulejová H, Himmlová L. The influence of implant surface properties on cell adhesion and proliferation. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 2007; 18:465-73. [PMID: 17334697 DOI: 10.1007/s10856-007-2006-0] [Citation(s) in RCA: 40] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/14/2005] [Accepted: 10/24/2005] [Indexed: 05/14/2023]
Abstract
Interactions of the foreign material of implant and the living tissue on the cell level can cause prolonged healing or, worse, loss of the implant. The cell response to the presence of some implant materials was studied under in vitro conditions. The influence of physicochemical surface parameters on the response of the cells in the immediate vicinity of implants, namely on adhesion, proliferation and synthetic activity of fibroblasts, and on the blood coagulation were compared. The direct contact of tested materials (titanium and Ti6Al4V alloy with various surface treatments, Cr Co Mo alloy, hydroxyapatite-coated titanium, zirconium oxide ceramics, polyethylene and carbon composite) on cell spreading was monitored and the presence of TNF-alpha and IL-8 was evaluated in the cultivation medium. The formation of blood clots was investigated on samples immersed in a well with freshly drawn whole rabbit blood using a scanning electron microscope. The surface free energy was estimated using the measurement of static contact angle. Both the advancing and receding contact angles were measured by the dynamic Wilhemy plate method. Two main groups with extremes in cell viability were established. In the first group the increased polar component of surface free energy, the highest cell density, the lowest inflammatory cytokine production, but no fibres in the clotting blood were found. On the contrary, the second group of materials with a very low polar component of the surface free energy showed distinctly higher expression of inflammatory mediators, low cell proliferation, but faster formation of fibres in the blood coagulum.
Collapse
Affiliation(s)
- V Pessková
- Rheumatological Institute, Na Slupi 4, Prague 2, Prague, Czech Republic.
| | | | | | | |
Collapse
|
28
|
Zhu X, Eibl O, Scheideler L, Geis-Gerstorfer J. Characterization of nano hydroxyapatite/collagen surfaces and cellular behaviors. J Biomed Mater Res A 2006; 79:114-27. [PMID: 16763987 DOI: 10.1002/jbm.a.30706] [Citation(s) in RCA: 51] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Osseointegration at the bone-implant interface is a prerequisite for endosseous implants to succeed in achieving and maintaining their long-term stability in bone tissue. The achievement of osseointegration is significantly affected by surface nature of implants. To optimize osseointegration, this study presents the characterization of synthesized nanocrystalline hydroxyapatite (nano HA) and in vitro studies on nano HA, nano-HA/collagen, and titanium surfaces. Voids were found within the grain of nano HA, which consisted of the shell and the core. The finding assists the clarification of microstructures of nano HA. By low-temperature mixing nano-HA sol with collagen gel (nano-HA/collagen 80:20), nano HA, and nano-HA/collagen coated on pure titanium or porous anodic titanium oxides resulted in higher wettability and lower roughness. The in vitro studies showed that porous structures produced by anodic oxides on titanium served as positive anchorage sites for cell filopodia to connect, and nano HA decreased cell attachment of osteoblasts and induced well-developed long filopodia and broad lamellipodia, thereby enhancing cellular motility. Collagen involvement enhanced cell adhesion to nano HA. Cell reactions to nano HA, nano-HA/collagen, native, and porous titanium surfaces provide some guidance for an optimal osseointegration by their application in surface modifications for implants.
Collapse
Affiliation(s)
- Xiaolong Zhu
- Section of Medical Materials and Technology, Department of Prosthodontics and Medical Materials, University of Tuebingen, Germany.
| | | | | | | |
Collapse
|
29
|
Blind O, Klein LH, Dailey B, Jordan L. Characterization of hydroxyapatite films obtained by pulsed-laser deposition on Ti and Ti-6AL-4v substrates. Dent Mater 2005; 21:1017-24. [PMID: 15882899 DOI: 10.1016/j.dental.2004.12.003] [Citation(s) in RCA: 79] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2004] [Revised: 10/01/2004] [Accepted: 12/02/2004] [Indexed: 11/29/2022]
Abstract
OBJECTIVES Pulsed-laser deposition (PLD) is a development process to obtain hydroxyapatite (HA) thin film. It is an alternative to hydroxyapatite deposition techniques usually employed to cover orthopaedic or dental titanium implant surfaces. The aim of this study is to find out the characteristic ratio for Ca/P (1.66) deposit on titanium implant with the PLD process. METHODS In a preliminary study, the coating parameters of pure and highly crystalline HA on Ti or Ti-6Al-4V substrates were verified by analysing the deposit by Rutherford backscattering spectroscopy (RBS). Ablation parameters to reach a stoichiometric hydroxyapatite composition (ideal Ca/P atomic ratio) and to control the growth of crystalline phases were: 575 degrees C for the substrate temperature, 0.4 mbar H2O vapour pressure in the ablation chamber, the target substrate distance was 40 mm and the deposition time was 120 min. In a second part, the film properties were analysed by means of XRD, SEM, AFM. The coating adhesion of the HA to the substrate was determined with a micro scratch tester. RESULTS The analysed HA thin films showed a perfect crystallized and textured deposit. Sample observation and surface quality analysis demonstrated a surface roughness and adhesion of the films to the substrates compatible with biological applications. SIGNIFICANCE These results suggest that pulsed-laser deposition is a suitable technique to obtain crystalline and adherent hydroxyapatite films on Ti or Ti-6Al-4V substrates. The quality of the HA deposit with the PLD process could be an interesting option for coating dental implant.
Collapse
Affiliation(s)
- Olivier Blind
- Faculté de Chirurgie Dentaire, Université Denis Diderot, Paris 7, France.
| | | | | | | |
Collapse
|
30
|
Bigi A, Bracci B, Cuisinier F, Elkaim R, Fini M, Mayer I, Mihailescu IN, Socol G, Sturba L, Torricelli P. Human osteoblast response to pulsed laser deposited calcium phosphate coatings. Biomaterials 2005; 26:2381-9. [PMID: 15585241 DOI: 10.1016/j.biomaterials.2004.07.057] [Citation(s) in RCA: 111] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2004] [Accepted: 07/23/2004] [Indexed: 11/16/2022]
Abstract
Octacalcium phosphate (OCP) and Mn(2+)-doped carbonate hydroxyapatite (Mn-CHA) thin films were deposited on pure, highly polished and chemically etched Ti substrates with pulsed laser deposition. The coatings exhibit different composition, crystallinity and morphology that might affect their osteoconductivity. Human osteoblasts were cultured on the surfaces of OCP and Mn-CHA thin films, and the cell attachment, proliferation and differentiation were evaluated up to 21 days. The cells showed a normal morphology and a very good rate of proliferation and viability in every experimental time. Alkaline phosphatase activity was always higher than the control and Ti groups. From days 7 to 21 collagen type I production was higher in comparison with control and Ti groups. The level of transforming growth factor beta 1 (TGF-beta1) was lower at 3 and 7 days, but reached the highest values during following experimental times (14 and 21 days). Our data demonstrate that both calcium phosphate coatings favour osteoblasts proliferation, activation of their metabolism and differentiation.
Collapse
Affiliation(s)
- A Bigi
- Department of Chemistry "G. Ciamician", University of Bologna, via Selmi, 2, Bologna 40126, Italy.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
31
|
Abstract
Solvents are widely used in commercial manufacturing and service industries. Despite abundant precaution, they inevitably contaminate our air, land, and water because they are difficult to contain and recycle. Researchers have therefore focused on reducing solvent use through the development of solvent-free processes and more efficient recycling protocols. However, these approaches have their limitations, necessitating a pollution prevention approach and the search for environmentally benign solvent alternatives. This report highlights opportunities for the practical implementation of such green solvents.
Collapse
Affiliation(s)
- Joseph M DeSimone
- Department of Chemistry, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599-3290, USA.
| |
Collapse
|
32
|
Ball MD, Downes S, Scotchford CA, Antonov EN, Bagratashvili VN, Popov VK, Lo WJ, Grant DM, Howdle SM. Osteoblast growth on titanium foils coated with hydroxyapatite by pulsed laser ablation. Biomaterials 2001; 22:337-47. [PMID: 11205437 DOI: 10.1016/s0142-9612(00)00189-7] [Citation(s) in RCA: 77] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
Abstract
Pulsed laser ablation is a new method for deposition of thin layers of hydroxyapatite (HA) on to biomaterial surfaces. In this paper, we report activity and morphology of osteoblasts grown on HA surfaces fabricated using different laser conditions. Two sets of films were deposited from dense HA targets, at three different laser fluences: 3, 6 and 9 Jcm(-2). One set of the surfaces was annealed at 575 degrees C to increase the crystallinity of the deposited films. Primary human osteoblasts were seeded onto the material surfaces and cytoskeletal actin organisation was examined using confocal laser scanning microscopy. The annealed surfaces supported greater cell attachment and more defined cytoskeletal actin organisation. Cell activity, measured using the alamar Blue assay, was also found to be significantly higher on the annealed samples. In addition, our results show distinct trends that correlate with the laser fluence used for deposition. The cell activity increases with increasing fluence. This pattern was repeated for alkaline phosphatase production by the cells. Differences in cell spreading were apparent which were correlated with the fluence used to deposit the HA. The optimum surface for initial attachment and spreading of osteoblasts was one of the HA films deposited using 9 J cm(-2) laser fluence and subsequently annealed at 575 degrees C.
Collapse
Affiliation(s)
- M D Ball
- Biomaterials Group, School of Biomedical Sciences, Queens' Medical Centre, University of Nottingham, UK
| | | | | | | | | | | | | | | | | |
Collapse
|