1
|
Separation Abilities of Capillary Electrophoresis Coupled with Ion Mobility Mass Spectrometry for the Discrete Detection of Sequence Isomeric Peptides. SEPARATIONS 2022. [DOI: 10.3390/separations9050106] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
The separation and discrete detection of isomeric sequence peptides with similar properties are important tasks for analytical science. Three different peptide isomers of 12 amino-acid residues long, containing direct and reverse regions of the alanine-valine-proline-isoleucine (AVPI) motif, were partially separated and discretely detected from their mixture using two approaches. Capillary electrophoresis enabled the separation and optical detection of the peptide sequence isomers close to the baseline. The ability to separate these sequence isomers from the mixture and discretely identify them from mass spectra has also been demonstrated by ion-mobility tandem mass spectrometry. Moreover, for the first time, capillary electrophoresis and ion-mobility mass spectrometry connected online have shown their ability for a discrete detection of the multidirectional sequence isomers.
Collapse
|
2
|
Ferré S, Boccard J, Rudaz S, González-Ruiz V. Evaluation of Prototype CE-MS Interfaces. Methods Mol Biol 2022; 2531:1-13. [PMID: 35941475 DOI: 10.1007/978-1-0716-2493-7_1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Capillary electrophoresis-mass spectrometry (CE-MS) coupling is a powerful analytical solution bringing together the separation power of CE and the wealth of chemical information afforded by MS. Nevertheless, interfaces making the hyphenation of both techniques possible have always been the subject of a quest for improvement by their users in search for more sensitive and robust setups. This fact has led to numerous technical developments and new interface designs claiming to outrival existing approaches in different aspects. Nevertheless, the task of evaluating and comparing a new interface to previous solutions is not always straightforward. Issued from our own experience in the field, we herein propose a protocol to optimize the operation parameters of a new CE-MS interface design, assess its analytical performance, and compare it to a reference interface if desired. Electrospray stability, sensitivity, reproducibility, and robustness are practically evaluated as key elements of the process.
Collapse
Affiliation(s)
- Sabrina Ferré
- Institute of Pharmaceutical Sciences of Western Switzerland (ISPSO), University of Geneva, Geneva, Switzerland
- School of Pharmaceutical Sciences, University of Geneva, Geneva, Switzerland
| | - Julien Boccard
- Institute of Pharmaceutical Sciences of Western Switzerland (ISPSO), University of Geneva, Geneva, Switzerland
- School of Pharmaceutical Sciences, University of Geneva, Geneva, Switzerland
- Swiss Centre for Applied Human Toxicology, Basel, Switzerland
| | - Serge Rudaz
- Institute of Pharmaceutical Sciences of Western Switzerland (ISPSO), University of Geneva, Geneva, Switzerland
- School of Pharmaceutical Sciences, University of Geneva, Geneva, Switzerland
- Swiss Centre for Applied Human Toxicology, Basel, Switzerland
| | - Víctor González-Ruiz
- Institute of Pharmaceutical Sciences of Western Switzerland (ISPSO), University of Geneva, Geneva, Switzerland.
- School of Pharmaceutical Sciences, University of Geneva, Geneva, Switzerland.
- Swiss Centre for Applied Human Toxicology, Basel, Switzerland.
| |
Collapse
|
3
|
On-line coupling of two-phase microelectroextraction to capillary electrophoresis – Mass spectrometry for metabolomics analyses. Microchem J 2021. [DOI: 10.1016/j.microc.2020.105741] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
|
4
|
Ferré S, Drouin N, González-Ruiz V, Rudaz S. Evaluation of a nanoflow interface based on the triple-tube coaxial sheath-flow sprayer for capillary electrophoresis-mass spectrometry coupling in metabolomics. J Chromatogr A 2021; 1641:461982. [PMID: 33611118 DOI: 10.1016/j.chroma.2021.461982] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2020] [Revised: 02/03/2021] [Accepted: 02/07/2021] [Indexed: 02/06/2023]
Abstract
The performance of an original CE-MS interface that allows the in-axis positioning of the electrospray with respect to the MS inlet was evaluated. The variations in the geometrical alignment of this configuration in the absence of a nebulizing gas afforded a significant reduction in the sheath-liquid flow rate from 3 µL/min to as low as 300 nL/min. The sheath liquid and BGE were respectively composed of H2O-iPrOHCH3COOH 50:50:1 (v/v/v) and 10% acetic acid (pH 2.2). A significant gain in sensitivity was obtained, and it was correlated to the effective mobility of the analytes. Compounds with low mobility values showed a greater sensitivity gain. Special attention was paid to the detection of proteinogenic amino acids. Linear response functions were obtained from 15 ng/mL to 500 ng/mL. The limits of quantification, as low as 34.3 ng/mL, were improved by a factor of up to six compared to the conventional configuration. The in-axis setup was ultimately applied to the absolute quantification of four important amino acids, alanine, tyrosine, methionine and valine, in standard reference material (NIST plasma). The accuracies ranged from 78 to 113%, thus demonstrating the potential of this configuration for metabolomics.
Collapse
Affiliation(s)
- Sabrina Ferré
- School of Pharmaceutical Sciences, University of Geneva, Geneva, Switzerland; Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, Geneva, Switzerland
| | - Nicolas Drouin
- School of Pharmaceutical Sciences, University of Geneva, Geneva, Switzerland; Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, Geneva, Switzerland
| | - Víctor González-Ruiz
- School of Pharmaceutical Sciences, University of Geneva, Geneva, Switzerland; Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, Geneva, Switzerland; Swiss Centre for Applied Human Toxicology (SCAHT), Switzerland
| | - Serge Rudaz
- School of Pharmaceutical Sciences, University of Geneva, Geneva, Switzerland; Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, Geneva, Switzerland; Swiss Centre for Applied Human Toxicology (SCAHT), Switzerland.
| |
Collapse
|
5
|
Sauer F, Sydow C, Trapp O. A robust sheath-flow CE-MS interface for hyphenation with Orbitrap MS. Electrophoresis 2020; 41:1280-1286. [PMID: 32358866 DOI: 10.1002/elps.202000044] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2020] [Revised: 04/21/2020] [Accepted: 04/23/2020] [Indexed: 11/10/2022]
Abstract
The hyphenation of capillary electrophoresis with high-resolution mass spectrometry, such as Orbitrap MS, is of broad interest for the unambiguous and exceptionally sensitive identification of compounds. However, the coupling of these techniques requires a robust ionization interface that does not influence the stability of the separation voltage while coping with oxidation of the emitter tip at large ionization voltages. Herein, we present the design of a sheath-flow CE-ESI-MS interface which combines a robust and easy to operate set-up with high-resolution Orbitrap MS detection. The sheath liquid interface is equipped with a gold coated electrospray emitter which increases the stability and overall lifetime of the system. For the characterization of the interface, the spray stability and durability were investigated in dependence of the sheath-flow rate, electrospray voltage, and additional gold coating. The optimized conditions were applied to a separation of angiotensin II and neurotensin resulting in LODs of 2.4 and 3.5 ng/mL.
Collapse
Affiliation(s)
- Fabian Sauer
- Department Chemie, Ludwig-Maximilians-Universität München, München, Germany
| | - Constanze Sydow
- Department Chemie, Ludwig-Maximilians-Universität München, München, Germany
| | - Oliver Trapp
- Department Chemie, Ludwig-Maximilians-Universität München, München, Germany.,Max-Planck-Institute for Astronomy, Heidelberg, Germany
| |
Collapse
|
6
|
Challenges in Analysis of Hydrophilic Metabolites Using Chromatography Coupled with Mass Spectrometry. JOURNAL OF ANALYSIS AND TESTING 2020. [DOI: 10.1007/s41664-020-00126-z] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|
7
|
Gomes FP, Yates JR. Recent trends of capillary electrophoresis-mass spectrometry in proteomics research. MASS SPECTROMETRY REVIEWS 2019; 38:445-460. [PMID: 31407381 PMCID: PMC6800771 DOI: 10.1002/mas.21599] [Citation(s) in RCA: 61] [Impact Index Per Article: 12.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
Progress in proteomics research has led to a demand for powerful analytical tools with high separation efficiency and sensitivity for confident identification and quantification of proteins, posttranslational modifications, and protein complexes expressed in cells and tissues. This demand has significantly increased interest in capillary electrophoresis-mass spectrometry (CE-MS) in the past few years. This review provides highlights of recent advances in CE-MS for proteomics research, including a short introduction to top-down mass spectrometry and native mass spectrometry (native MS), as well as a detailed overview of CE methods. Both the potential and limitations of these methods for the analysis of proteins and peptides in synthetic and biological samples and the challenges of CE methods are discussed, along with perspectives about the future direction of CE-MS. @ 2019 Wiley Periodicals, Inc. Mass Spec Rev 00:1-16, 2019.
Collapse
Affiliation(s)
| | - John R. Yates
- Correspondent author: , Phone number: (858) 784-8862, Departments of Molecular Medicine and Neurobiology, 10550 North Torrey Pines Road, SR302B, The Scripps Research Institute, La Jolla, CA 92037
| |
Collapse
|
8
|
Ferré S, González-Ruiz V, Guillarme D, Rudaz S. Analytical strategies for the determination of amino acids: Past, present and future trends. J Chromatogr B Analyt Technol Biomed Life Sci 2019; 1132:121819. [PMID: 31704619 DOI: 10.1016/j.jchromb.2019.121819] [Citation(s) in RCA: 47] [Impact Index Per Article: 9.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2019] [Revised: 09/25/2019] [Accepted: 09/27/2019] [Indexed: 12/27/2022]
Abstract
This review describes the analytical methods that have been developed over the years to tackle the high polarity and non-chromophoric nature of amino acids (AAs). First, the historical methods are briefly presented, with a strong focus on the use of derivatization reagents to make AAs detectable with spectroscopic techniques (ultraviolet and fluorescence) and/or sufficiently retained in reversed phase liquid chromatography. Then, an overview of the current analytical strategies for achiral separation of AAs is provided, in which mass spectrometry (MS) becomes the most widely used detection mode in combination with innovative liquid chromatography or capillary electrophoresis conditions to detect AAs at very low concentration in complex matrixes. Finally, some future trends of AA analysis are provided in the last section of the review, including the use of supercritical fluid chromatography (SFC), multidimensional liquid chromatography and electrophoretic separations, hyphenation of ion exchange chromatography to mass spectrometry, and use of ion mobility spectrometry mass spectrometry (IM-MS). Various application examples will also be presented throughout the review to highlight the benefits and limitations of these different analytical approaches for AAs determination.
Collapse
Affiliation(s)
- Sabrina Ferré
- Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, CMU - Rue Michel Servet 1, 1211 Geneva 4, Switzerland
| | - Víctor González-Ruiz
- Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, CMU - Rue Michel Servet 1, 1211 Geneva 4, Switzerland; Swiss Centre for Applied Human Toxicology (SCAHT), Switzerland
| | - Davy Guillarme
- Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, CMU - Rue Michel Servet 1, 1211 Geneva 4, Switzerland.
| | - Serge Rudaz
- Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, CMU - Rue Michel Servet 1, 1211 Geneva 4, Switzerland; Swiss Centre for Applied Human Toxicology (SCAHT), Switzerland
| |
Collapse
|
9
|
Azab S, Ly R, Britz-McKibbin P. Robust Method for High-Throughput Screening of Fatty Acids by Multisegment Injection-Nonaqueous Capillary Electrophoresis–Mass Spectrometry with Stringent Quality Control. Anal Chem 2018; 91:2329-2336. [DOI: 10.1021/acs.analchem.8b05054] [Citation(s) in RCA: 43] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Affiliation(s)
- Sandi Azab
- Department of Chemistry and Chemical Biology, McMaster University, Hamilton, Ontario, L8S 4M1, Canada
| | - Ritchie Ly
- Department of Chemistry and Chemical Biology, McMaster University, Hamilton, Ontario, L8S 4M1, Canada
| | - Philip Britz-McKibbin
- Department of Chemistry and Chemical Biology, McMaster University, Hamilton, Ontario, L8S 4M1, Canada
| |
Collapse
|
10
|
Francisco KJM, do Lago CL. Improving thermal control of capillary electrophoresis with mass spectrometry and capacitively coupled contactless conductivity detection by using 3D printed cartridges. Talanta 2018; 185:37-41. [PMID: 29759214 DOI: 10.1016/j.talanta.2018.03.052] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2017] [Revised: 03/14/2018] [Accepted: 03/15/2018] [Indexed: 10/17/2022]
Abstract
A 3D-printed cartridge was developed to improve the interface between a capillary electrophoresis instrument and a mass spectrometer. The thermostated airflow from the CE was guided to the entrance of the electrospray source keeping as much as possible the silica capillary in a proper Joule-heating dissipation environment. Hollow 3D-printed walls made of ABS covered by a 0.2 mm thick copper foil on the inner side were used. The cartridge also allows including up to two capacitively coupled contactless conductivity detectors (C4Ds). Experiments about the separation of monoethyl carbonate (a thermally unstable species) shows that the peak area obtained with the original cartridge is only 21% of the value obtained with the 3D-printed cartridge, which demonstrates the improvement in heat dissipation.
Collapse
Affiliation(s)
- Kelliton José Mendonça Francisco
- Department of Fundamental Chemistry, Institute of Chemistry, University of São Paulo, Av. Prof. Lineu Prestes, 748, São Paulo, SP CEP 05508-000, Brazil.
| | - Claudimir Lucio do Lago
- Department of Fundamental Chemistry, Institute of Chemistry, University of São Paulo, Av. Prof. Lineu Prestes, 748, São Paulo, SP CEP 05508-000, Brazil.
| |
Collapse
|
11
|
González-Ruiz V, Codesido S, Rudaz S, Schappler J. Evolution in the design of a low sheath-flow interface for CE-MS and application to biological samples. Electrophoresis 2017; 39:853-861. [DOI: 10.1002/elps.201700328] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2017] [Revised: 10/20/2017] [Accepted: 10/21/2017] [Indexed: 12/14/2022]
Affiliation(s)
- Víctor González-Ruiz
- School of Pharmaceutical Sciences, University of Geneva; University of Lausanne; Geneva Switzerland
| | | | - Serge Rudaz
- School of Pharmaceutical Sciences, University of Geneva; University of Lausanne; Geneva Switzerland
| | - Julie Schappler
- School of Pharmaceutical Sciences, University of Geneva; University of Lausanne; Geneva Switzerland
| |
Collapse
|
12
|
Yi L, Piehowski PD, Shi T, Smith RD, Qian WJ. Advances in microscale separations towards nanoproteomics applications. J Chromatogr A 2017; 1523:40-48. [PMID: 28765000 PMCID: PMC6042839 DOI: 10.1016/j.chroma.2017.07.055] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2017] [Revised: 07/14/2017] [Accepted: 07/17/2017] [Indexed: 01/22/2023]
Abstract
Microscale separation (e.g., liquid chromatography or capillary electrophoresis) coupled with mass spectrometry (MS) has become the primary tool for advanced proteomics, an indispensable technology for gaining understanding of complex biological processes. In recent decades significant advances have been achieved in MS-based proteomics. However, the current proteomics platforms still face an analytical challenge in overall sensitivity towards nanoproteomics applications for starting materials of less than 1μg total proteins (e.g., cellular heterogeneity in tissue pathologies). Herein, we review recent advances in microscale separation techniques and integrated sample processing strategies that improve the overall sensitivity and proteome coverage of the proteomics workflow, and their contributions towards nanoproteomics applications.
Collapse
Affiliation(s)
- Lian Yi
- Biological Sciences Division and Environmental Molecular Sciences Laboratory, Pacific Northwest National Laboratory, Richland, WA 99352, United States
| | - Paul D Piehowski
- Biological Sciences Division and Environmental Molecular Sciences Laboratory, Pacific Northwest National Laboratory, Richland, WA 99352, United States
| | - Tujin Shi
- Biological Sciences Division and Environmental Molecular Sciences Laboratory, Pacific Northwest National Laboratory, Richland, WA 99352, United States
| | - Richard D Smith
- Biological Sciences Division and Environmental Molecular Sciences Laboratory, Pacific Northwest National Laboratory, Richland, WA 99352, United States
| | - Wei-Jun Qian
- Biological Sciences Division and Environmental Molecular Sciences Laboratory, Pacific Northwest National Laboratory, Richland, WA 99352, United States.
| |
Collapse
|
13
|
Bertoletti L, Schappler J, Colombo R, Rudaz S, Haselberg R, Domínguez-Vega E, Raimondi S, Somsen GW, De Lorenzi E. Evaluation of capillary electrophoresis-mass spectrometry for the analysis of the conformational heterogeneity of intact proteins using beta 2-microglobulin as model compound. Anal Chim Acta 2016; 945:102-109. [PMID: 27968711 DOI: 10.1016/j.aca.2016.10.010] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2016] [Revised: 10/07/2016] [Accepted: 10/09/2016] [Indexed: 10/20/2022]
Abstract
In this work we explored the feasibility of different CE-ESI-MS set-ups for the analysis of conformational states of an intact protein. By using the same background electrolyte at quasi physiological conditions (50 mM ammonium bicarbonate, pH 7.4) a sequential optimization was carried out, initially by evaluating a sheath-liquid interface with both a single quadrupole (SQ) and a time-of-flight (TOF) mass spectrometer; then a sheathless interface coupled with high-resolution QTOF MS was considered. Beta2-microglobulin has been taken as a model, as it is an amyloidogenic protein and its conformational changes are strictly connected to the onset of a disease. The separation of two conformers at dynamic equilibrium is achieved all the way down to the MS detection. Notably, the equilibrium ratio of the protein conformers is maintained in the electrospray source after CE separation. Strengths and weaknesses of each optimized set-up are emphasized and their feasibility in unfolding studies is evaluated. In particular, ESI-TOF MS can assign protein forms that differ by 1 Da only and sheathless interfacing is best suited to preserve protein structure integrity. This demonstrates the CE-ESI-MS performance in terms of separation, detection and characterization of conformational species that co-populate a protein solution.
Collapse
Affiliation(s)
- Laura Bertoletti
- Department of Drug Sciences, University of Pavia, Viale Taramelli 12, 27100, Pavia, Italy.
| | - Julie Schappler
- School of Pharmaceutical Sciences, University of Geneva, University of Lausanne, CMU, Rue Michel Servet 1, 1211, Geneva 4, Switzerland.
| | - Raffaella Colombo
- Department of Drug Sciences, University of Pavia, Viale Taramelli 12, 27100, Pavia, Italy.
| | - Serge Rudaz
- School of Pharmaceutical Sciences, University of Geneva, University of Lausanne, CMU, Rue Michel Servet 1, 1211, Geneva 4, Switzerland.
| | - Rob Haselberg
- Division of BioAnalytical Chemistry, AIMMS Research Group BioMolecular Analysis, Vrije Universiteit Amsterdam, De Boelelaan 1085, 1081 HV, Amsterdam, The Netherlands.
| | - Elena Domínguez-Vega
- Division of BioAnalytical Chemistry, AIMMS Research Group BioMolecular Analysis, Vrije Universiteit Amsterdam, De Boelelaan 1085, 1081 HV, Amsterdam, The Netherlands.
| | - Sara Raimondi
- Department of Molecular Medicine, Institute of Biochemistry, University of Pavia, Viale Taramelli 3b, 27100, Pavia, Italy.
| | - Govert W Somsen
- Division of BioAnalytical Chemistry, AIMMS Research Group BioMolecular Analysis, Vrije Universiteit Amsterdam, De Boelelaan 1085, 1081 HV, Amsterdam, The Netherlands.
| | - Ersilia De Lorenzi
- Department of Drug Sciences, University of Pavia, Viale Taramelli 12, 27100, Pavia, Italy.
| |
Collapse
|
14
|
A micellar electrokinetic chromatography-mass spectrometry approach using in-capillary diastereomeric derivatization for fully automatized chiral analysis of amino acids. J Chromatogr A 2016; 1467:400-408. [PMID: 27554025 DOI: 10.1016/j.chroma.2016.08.035] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2016] [Revised: 08/12/2016] [Accepted: 08/15/2016] [Indexed: 11/20/2022]
Abstract
In the context of bioanalytical method development, process automatization is nowadays a necessity in order to save time, improve method reliability and reduce costs. For the first time, a fully automatized micellar electrokinetic chromatography-mass spectrometry (MEKC-MS) method with in-capillary derivatization was developed for the chiral analysis of d- and l-amino acids using (-)-1-(9-fluorenyl) ethyl chloroformate (FLEC) as labeling reagent. The derivatization procedure was optimized using an experimental design approach leading to the following conditions: sample and FLEC plugs in a 2:1 ratio (15s, 30mbar: 7.5s, 30mbar) followed by 15min of mixing using a voltage of 0.1kV. The formed diastereomers were then separated using a background electrolyte (BGE) consisting of 150mM ammonium perfluorooctanoate (APFO) (pH=9.5) and detected by mass spectrometry (MS). Complete chiral resolution was obtained for 8 amino acids, while partial separation was achieved for 6 other amino acid pairs. The method showed good reproducibility and linearity in the low micromolar concentration range. The applicability of the method to biological samples was tested by analyzing artificial cerebrospinal fluid (aCSF) samples.
Collapse
|
15
|
Declerck S, Vander Heyden Y, Mangelings D. Enantioseparations of pharmaceuticals with capillary electrochromatography: A review. J Pharm Biomed Anal 2016; 130:81-99. [PMID: 27156645 DOI: 10.1016/j.jpba.2016.04.024] [Citation(s) in RCA: 56] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2016] [Revised: 04/13/2016] [Accepted: 04/17/2016] [Indexed: 11/19/2022]
Abstract
The chiral separation of pharmaceuticals is one of the major research topics in the pharmaceutical industry. Chromatographic techniques are most frequently used in this context. Separations in capillary electrochromatography (CEC) are an alternative and achieved by chromatographic retention and electrophoretic mobility principles. As a result, CEC is characterized by a high selectivity and efficiency. The limited number of stationary phases specifically developed for CEC, the low number of commercially available CEC columns, the frits to maintain the stationary phase, which forms fragile spots in the columns, and the limited column robustness and reproducibility, make CEC not very attractive for industrial application. However, CEC is still applied and studied in the academic field. This review discusses the enantioseparation of drugs in CEC published during the last four years, with a critical view on the reproducibility and the practical utility of these applications.
Collapse
Affiliation(s)
- Sven Declerck
- Department of Analytical Chemistry and Pharmaceutical Technology (FABI), Center for Pharmaceutical Research (CePhaR), Vrije Universiteit Brussel-VUB, Laarbeeklaan 103, B-1090 Brussels, Belgium.
| | - Yvan Vander Heyden
- Department of Analytical Chemistry and Pharmaceutical Technology (FABI), Center for Pharmaceutical Research (CePhaR), Vrije Universiteit Brussel-VUB, Laarbeeklaan 103, B-1090 Brussels, Belgium.
| | - Debby Mangelings
- Department of Analytical Chemistry and Pharmaceutical Technology (FABI), Center for Pharmaceutical Research (CePhaR), Vrije Universiteit Brussel-VUB, Laarbeeklaan 103, B-1090 Brussels, Belgium.
| |
Collapse
|
16
|
González-Ruiz V, Codesido S, Far J, Rudaz S, Schappler J. Evaluation of a new low sheath-flow interface for CE-MS. Electrophoresis 2016; 37:936-46. [DOI: 10.1002/elps.201500523] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2015] [Revised: 01/27/2016] [Accepted: 01/28/2016] [Indexed: 01/27/2023]
Affiliation(s)
- Víctor González-Ruiz
- School of Pharmaceutical Sciences, University of Geneva; University of Lausanne; Geneva 4 Switzerland
| | | | - Johann Far
- Laboratory of Mass Spectrometry, Chemistry Institute; University of Liège; Liège Belgium
- Analis; Suarlee Belgium
| | - Serge Rudaz
- School of Pharmaceutical Sciences, University of Geneva; University of Lausanne; Geneva 4 Switzerland
| | - Julie Schappler
- School of Pharmaceutical Sciences, University of Geneva; University of Lausanne; Geneva 4 Switzerland
| |
Collapse
|
17
|
Heemskerk AAM, Deelder AM, Mayboroda OA. CE-ESI-MS for bottom-up proteomics: Advances in separation, interfacing and applications. MASS SPECTROMETRY REVIEWS 2016; 35:259-271. [PMID: 24852088 DOI: 10.1002/mas.21432] [Citation(s) in RCA: 43] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/15/2014] [Accepted: 03/27/2014] [Indexed: 06/03/2023]
Abstract
With the development of more sensitive hyphenation strategies for capillary electrophoresis-electrospray-mass spectrometry the technique has reemerged as technique with high separation power combined with high sensitivity in the analysis of peptides and protein digests. This review will discuss the newly developed hyphenation strategies for CE-ESI-MS and their application in bottom-up proteomics as well as the applications in the same time span, 2009 to present, using co-axial sheathliquid. Subsequently all separate aspects in the development of a CE-ESI-MS method for bottom-up proteomics shall be discussed, highlighting certain applications and discussing pros and cons of the various choices. The separation of peptides in a capillary electrophoresis system is discussed including the great potential for modeling of this migration of peptides due to the simple electrophoretic separation process. Furthermore, the technical aspects of method development are discussed, namely; background electrolyte choice, coating of the separation capillary and chosen loading method. Finally, conclusions and an outlook on future developments in the field of bottom-up proteomics by CE-ESI-MS will be provided.
Collapse
Affiliation(s)
- Anthonius A M Heemskerk
- Center for Proteomics and Metabolomics, Leiden University Medical Center, Albinusdreef 2, 2300, RC, Leiden, The Netherlands
| | - André M Deelder
- Center for Proteomics and Metabolomics, Leiden University Medical Center, Albinusdreef 2, 2300, RC, Leiden, The Netherlands
| | - Oleg A Mayboroda
- Center for Proteomics and Metabolomics, Leiden University Medical Center, Albinusdreef 2, 2300, RC, Leiden, The Netherlands
| |
Collapse
|
18
|
Liu Y, Jann M, Vandenberg C, Eap CB, Shamsi SA. Development of an enantioselective assay for simultaneous separation of venlafaxine and O-desmethylvenlafaxine by micellar electrokinetic chromatography-tandem mass spectrometry: Application to the analysis of drug-drug interaction. J Chromatogr A 2015; 1420:119-28. [PMID: 26460073 PMCID: PMC5025041 DOI: 10.1016/j.chroma.2015.09.088] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2015] [Revised: 09/27/2015] [Accepted: 09/29/2015] [Indexed: 11/30/2022]
Abstract
To-date, there has been no effective chiral capillary electrophoresis-mass spectrometry (CE-MS) method reported for the simultaneous enantioseparation of the antidepressant drug, venlafaxine (VX) and its structurally-similar major metabolite, O-desmethylvenlafaxine (O-DVX). This is mainly due to the difficulty of identifying MS compatible chiral selector, which could provide both high enantioselectivity and sensitive MS detection. In this work, poly-sodium N-undecenoyl-L,L-leucylalaninate (poly-L,L-SULA) was employed as a chiral selector after screening several dipeptide polymeric chiral surfactants. Baseline separation of both O-DVX and VX enantiomers was achieved in 15 min after optimizing the buffer pH, poly-L,L-SULA concentration, nebulizer pressure and separation voltage. Calibration curves in spiked plasma (recoveries higher than 80%) were linear over the concentration range 150-5000 ng/mL for both VX and O-DVX. The limit of detection (LOD) was found to be as low as 30 ng/mL and 21 ng/mL for O-DVX and VX, respectively. This method was successfully applied to measure the plasma concentrations of human volunteers receiving VX or O-DVX orally when co-administered without and with indinivar therapy. The results suggest that micellar electrokinetic chromatography electrospray ionization-tandem mass spectrometry (MEKC-ESI-MS/MS) is an effective low cost alternative technique for the pharmacokinetics and pharmacodynamics studies of both O-DVX and VX enantiomers. The technique has potential to identify drug-drug interaction involving VX and O-DVX enantiomers while administering indinivar therapy.
Collapse
Affiliation(s)
- Yijin Liu
- Center of Diagnostics and Therapeutics, Georgia State University, Atlanta, GA 30303, United States
| | - Michael Jann
- Health Science Center, University of North Texas, Fort Worth, TX 76107, United States
| | - Chad Vandenberg
- Midwestern University, Institute for Healthcare Innovation, Glendale, AZ 85308, United States
| | - Chin B Eap
- Unit of Pharmacogenetics and Clinical Psychopharmacology, Department of Psychiatry, Lausanne University, Hospital of Cery, Prilly, Lausanne, Switzerland
| | - Shahab A Shamsi
- Center of Diagnostics and Therapeutics, Georgia State University, Atlanta, GA 30303, United States.
| |
Collapse
|
19
|
Ramautar R, Somsen GW, de Jong GJ. CE-MS for metabolomics: Developments and applications in the period 2012-2014. Electrophoresis 2014; 36:212-24. [DOI: 10.1002/elps.201400388] [Citation(s) in RCA: 82] [Impact Index Per Article: 8.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2014] [Revised: 09/25/2014] [Accepted: 09/26/2014] [Indexed: 01/15/2023]
Affiliation(s)
- Rawi Ramautar
- Division of Analytical Biosciences; LACDR; Leiden University; Leiden The Netherlands
| | - Govert W. Somsen
- AIMMS research group BioMolecular Analysis; Division of BioAnalytical Chemistry; VU University Amsterdam; Amsterdam The Netherlands
| | - Gerhardus J. de Jong
- Biomolecular Analysis; Utrecht Institute for Pharmaceutical Sciences; Utrecht University; Utrecht The Netherlands
| |
Collapse
|
20
|
Lindenburg PW, Haselberg R, Rozing G, Ramautar R. Developments in Interfacing Designs for CE–MS: Towards Enabling Tools for Proteomics and Metabolomics. Chromatographia 2014. [DOI: 10.1007/s10337-014-2795-5] [Citation(s) in RCA: 58] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
|
21
|
Kok MG, Somsen GW, de Jong GJ. The role of capillary electrophoresis in metabolic profiling studies employing multiple analytical techniques. Trends Analyt Chem 2014. [DOI: 10.1016/j.trac.2014.06.004] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
|
22
|
Hirayama A, Wakayama M, Soga T. Metabolome analysis based on capillary electrophoresis-mass spectrometry. Trends Analyt Chem 2014. [DOI: 10.1016/j.trac.2014.05.005] [Citation(s) in RCA: 65] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
|
23
|
Gahoual R, Busnel JM, Beck A, François YN, Leize-Wagner E. Full Antibody Primary Structure and Microvariant Characterization in a Single Injection Using Transient Isotachophoresis and Sheathless Capillary Electrophoresis–Tandem Mass Spectrometry. Anal Chem 2014; 86:9074-81. [DOI: 10.1021/ac502378e] [Citation(s) in RCA: 71] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
Affiliation(s)
- Rabah Gahoual
- Laboratoire
de Spectrométrie de Masse des Interactions et des Systèmes
(LSMIS), UDS-CNRS UMR 7140, Université de Strasbourg, Strasbourg, France
| | | | - Alain Beck
- Centre d’immunologie
Pierre Fabre, Saint-Julien-en-Genevois, France
| | - Yannis-Nicolas François
- Laboratoire
de Spectrométrie de Masse des Interactions et des Systèmes
(LSMIS), UDS-CNRS UMR 7140, Université de Strasbourg, Strasbourg, France
| | - Emmanuelle Leize-Wagner
- Laboratoire
de Spectrométrie de Masse des Interactions et des Systèmes
(LSMIS), UDS-CNRS UMR 7140, Université de Strasbourg, Strasbourg, France
| |
Collapse
|
24
|
do Lago CL, Vidal DTR, Francisco KJM, dos Santos VB. A simple approach to compensate the suction caused by the electrospray ionization source in capillary electrophoresis-mass spectrometry systems. Electrophoresis 2014; 35:2412-6. [DOI: 10.1002/elps.201300651] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2013] [Revised: 02/20/2014] [Accepted: 02/21/2014] [Indexed: 12/17/2022]
Affiliation(s)
- Claudimir Lucio do Lago
- Departamento de Química Fundamental, Instituto de Química; Universidade de São Paulo; São Paulo SP Brazil
| | - Denis Tadeu Rajh Vidal
- Departamento de Química Fundamental, Instituto de Química; Universidade de São Paulo; São Paulo SP Brazil
| | | | - Vagner Bezerra dos Santos
- Departamento de Química Fundamental, Instituto de Química; Universidade de São Paulo; São Paulo SP Brazil
| |
Collapse
|
25
|
Bonvin G, Schappler J, Rudaz S. Non-aqueous capillary electrophoresis for the analysis of acidic compounds using negative electrospray ionization mass spectrometry. J Chromatogr A 2013; 1323:163-73. [PMID: 24315358 DOI: 10.1016/j.chroma.2013.11.011] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2013] [Revised: 10/30/2013] [Accepted: 11/01/2013] [Indexed: 01/09/2023]
Abstract
Non-aqueous capillary electrophoresis (NACE) is an attractive CE mode, in which water solvent of the background electrolyte (BGE) is replaced by organic solvent or by a mixture of organic solvents. This substitution alters several parameters, such as the pKa, permittivity, viscosity, zeta potential, and conductivity, resulting in a modification of CE separation performance (i.e., selectivity and/or efficiency). In addition, the use of NACE is particularly well adapted to ESI-MS due to the high volatility of solvents and the low currents that are generated. Organic solvents reduce the number of side electrochemical reactions at the ESI tip, thereby allowing the stabilization of the ESI current and a decrease in background noise. All these features make NACE an interesting alternative to the aqueous capillary zone electrophoresis (CZE) mode, especially in combination with mass spectrometry (MS) detection. The aim of this work was to evaluate the use of NACE coupled to negative ESI-MS for the analysis of acidic compounds with two available CE-MS interfaces (sheath liquid and sheathless). First, NACE was compared to aqueous CZE for the analysis of several pharmaceutical acidic compounds (non-steroidal anti-inflammatory drugs, NSAIDs). Then, the separation performance and the sensitivity achieved by both interfaces were evaluated, as were the impact of the BGE and the sample composition. Finally, analyses of glucuronides in urine samples subjected to a minimal sample pre-treatment ("dilute-and-shoot") were performed by NACE-ESI-MS, and the matrix effect was evaluated. A 20- to 100-fold improvement in sensitivity was achieved using the NACE mode in combination with the sheathless interface and no matrix effect was observed regardless of the interfaces.
Collapse
Affiliation(s)
- Grégoire Bonvin
- School of Pharmaceutical Sciences, University of Geneva, University of Lausanne, Bd d'Yvoy 20, 1211 Geneva 4, Switzerland
| | - Julie Schappler
- School of Pharmaceutical Sciences, University of Geneva, University of Lausanne, Bd d'Yvoy 20, 1211 Geneva 4, Switzerland
| | - Serge Rudaz
- School of Pharmaceutical Sciences, University of Geneva, University of Lausanne, Bd d'Yvoy 20, 1211 Geneva 4, Switzerland.
| |
Collapse
|
26
|
Marie AL, Przybylski C, Gonnet F, Daniel R, Urbain R, Chevreux G, Jorieux S, Taverna M. Capillary zone electrophoresis and capillary electrophoresis-mass spectrometry for analyzing qualitative and quantitative variations in therapeutic albumin. Anal Chim Acta 2013; 800:103-10. [DOI: 10.1016/j.aca.2013.09.023] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2013] [Revised: 07/29/2013] [Accepted: 09/11/2013] [Indexed: 01/06/2023]
|
27
|
Gusenkov S, Ackaert C, Stutz H. Separation and characterization of nitrated variants of the major birch pollen allergen by CZE-ESI-μTOF MS. Electrophoresis 2013; 34:2695-704. [PMID: 23857337 PMCID: PMC3816331 DOI: 10.1002/elps.201300151] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2013] [Revised: 05/15/2013] [Accepted: 05/21/2013] [Indexed: 11/11/2022]
Abstract
A CZE-ESI-TOF MS method has been optimized for the separation and identification of nitrated variants of the major birch pollen allergen from Betula verrucosa, isoform 1a (Bet v 1a). In-house nitration of recombinant Bet v 1a was done by peroxynitrite. As a BGE, 10 mmol/L ammonium bicarbonate with pH 7.50 provided best resolution. Nebulizer gas pressure and sheath liquid flow rate of 0.4 bar and 6 μL/min, respectively, maintained CZE selectivity and constituted stable electrospray conditions. A sheath liquid composition of 75% v/v methanol with 0.1% v/v formic acid in ultrapure water resulted in highest signal intensities. Alternatively, methanol could be replaced by 50% v/v isopropanol. Two modified allergen products derived from reaction mixtures that contained different amounts of the nitration reagent were compared by the elaborated CZE-ESI-TOF MS method. Up to twelve different Bet v 1a variants with one- to sixfold nitration could be distinguished. Several allergen fractions of equivalent nitration grade were resolved. Their different migration times indicate site-specific nitration with concomitant differences in pI and maybe also in hydrodynamic radius. The method allows for a characterization of in-house nitrated allergen samples that are intended for testing the postulated enhanced allergenicity of nitrated Bet v 1a variants.
Collapse
Affiliation(s)
- Sergey Gusenkov
- Division of Chemistry and Bioanalytics, Department of Molecular Biology, University of Salzburg, Salzburg, Austria
| | | | | |
Collapse
|
28
|
Kuehnbaum NL, Britz-McKibbin P. New Advances in Separation Science for Metabolomics: Resolving Chemical Diversity in a Post-Genomic Era. Chem Rev 2013; 113:2437-68. [DOI: 10.1021/cr300484s] [Citation(s) in RCA: 201] [Impact Index Per Article: 18.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Affiliation(s)
- Naomi L. Kuehnbaum
- Department of Chemistry
and Chemical Biology, McMaster University, Hamilton, Canada
| | | |
Collapse
|
29
|
Bonvin G, Schappler J, Rudaz S. Capillary electrophoresis–electrospray ionization-mass spectrometry interfaces: Fundamental concepts and technical developments. J Chromatogr A 2012; 1267:17-31. [DOI: 10.1016/j.chroma.2012.07.019] [Citation(s) in RCA: 66] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2012] [Revised: 07/04/2012] [Accepted: 07/06/2012] [Indexed: 01/24/2023]
|
30
|
Krenkova J, Foret F. On-line CE/ESI/MS interfacing: recent developments and applications in proteomics. Proteomics 2012; 12:2978-90. [PMID: 22888067 DOI: 10.1002/pmic.201200140] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2012] [Revised: 05/17/2012] [Accepted: 06/12/2012] [Indexed: 12/13/2022]
Abstract
After shining as the ultimate separation - sequencing technique used for the successful completion of the Human Genome Project, in the early 2000s CE experienced lowered popularity among separation scientists. The renewed interest in recent years relates to the separation needs, especially in proteomics, metabolomics, and glycomics, where CE complements liquid chromatography techniques. This interest is further boosted by the regulators requiring additional separation techniques for characterization of newly developed pharmaceuticals. This paper gives a short overview of recent developments in the on-line interfacing of CE separation techniques with electrospray ionization/mass spectrometric analysis. Both the instrumentation and selected CE/ESI/MS applications including analyses of peptides, proteins, and glycans are discussed with the stress on research published in the past 3 years. Techniques related to the proteomic and glycomic analyses such as sample preconcentration, on-line protein digestion, and analyte derivatization prior CE/ESI/MS analysis are also included.
Collapse
Affiliation(s)
- Jana Krenkova
- Institute of Analytical Chemistry of the ASCR, Brno, Czech Republic.
| | | |
Collapse
|
31
|
Ramautar R, Heemskerk AAM, Hensbergen PJ, Deelder AM, Busnel JM, Mayboroda OA. CE-MS for proteomics: Advances in interface development and application. J Proteomics 2012; 75:3814-28. [PMID: 22609513 DOI: 10.1016/j.jprot.2012.04.050] [Citation(s) in RCA: 64] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2012] [Revised: 04/23/2012] [Accepted: 04/30/2012] [Indexed: 12/25/2022]
Abstract
Capillary electrophoresis-mass spectrometry (CE-MS) has emerged as a powerful technique for the analysis of proteins and peptides. Over the past few years, significant progress has been made in the development of novel and more effective interfaces for hyphenating CE to MS. This review provides an overview of these new interfacing techniques for coupling CE to MS, covering the scientific literature from January 2007 to December 2011. The potential of these new CE-MS interfacing techniques is demonstrated within the field of (clinical) proteomics, more specifically "bottom-up" proteomics, by showing examples of the analysis of various biological samples. The relevant papers on CE-MS for proteomics are comprehensively summarized in tables, including, e.g. information on sample type and pretreatment, interfacing and MS detection mode. Finally, general conclusions and future perspectives are provided.
Collapse
Affiliation(s)
- Rawi Ramautar
- Biomolecular Mass Spectrometry Unit, Department of Parasitology, Leiden University Medical Center, Albinusdreef 2, 2300 RC, Leiden, The Netherlands.
| | | | | | | | | | | |
Collapse
|
32
|
Bonvin G, Veuthey JL, Rudaz S, Schappler J. Evaluation of a sheathless nanospray interface based on a porous tip sprayer for CE-ESI-MS coupling. Electrophoresis 2012; 33:552-62. [DOI: 10.1002/elps.201100461] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
33
|
Ramautar R, Busnel JM, Deelder AM, Mayboroda OA. Enhancing the Coverage of the Urinary Metabolome by Sheathless Capillary Electrophoresis-Mass Spectrometry. Anal Chem 2011; 84:885-92. [DOI: 10.1021/ac202407v] [Citation(s) in RCA: 106] [Impact Index Per Article: 8.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Affiliation(s)
- Rawi Ramautar
- Biomolecular Mass Spectrometry Unit, Department of Parasitology, Leiden University Medical Center, Leiden, The Netherlands
| | - Jean-Marc Busnel
- Biomolecular Mass Spectrometry Unit, Department of Parasitology, Leiden University Medical Center, Leiden, The Netherlands
- Beckman Coulter, Inc., Brea, California 92822, United States
| | - André M. Deelder
- Biomolecular Mass Spectrometry Unit, Department of Parasitology, Leiden University Medical Center, Leiden, The Netherlands
| | - Oleg A. Mayboroda
- Biomolecular Mass Spectrometry Unit, Department of Parasitology, Leiden University Medical Center, Leiden, The Netherlands
| |
Collapse
|
34
|
Kuehnbaum NL, Britz-McKibbin P. Comprehensive Profiling of Free and Conjugated Estrogens by Capillary Electrophoresis–Time of Flight/Mass Spectrometry. Anal Chem 2011; 83:8063-8. [DOI: 10.1021/ac201980w] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
Affiliation(s)
- Naomi L. Kuehnbaum
- Department of Chemistry and Chemical Biology, McMaster University, Hamilton, Ontario L8S 4MI, Canada
| | - Philip Britz-McKibbin
- Department of Chemistry and Chemical Biology, McMaster University, Hamilton, Ontario L8S 4MI, Canada
| |
Collapse
|
35
|
Grundmann M, Matysik FM. Fast capillary electrophoresis–time-of-flight mass spectrometry using capillaries with inner diameters ranging from 75 to 5 μm. Anal Bioanal Chem 2011; 400:269-78. [DOI: 10.1007/s00216-011-4719-7] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2010] [Revised: 12/23/2010] [Accepted: 01/20/2011] [Indexed: 10/18/2022]
|
36
|
Britz-McKibbin P. Capillary electrophoresis-electrospray ionization-mass spectrometry (CE-ESI-MS)-based metabolomics. Methods Mol Biol 2011; 708:229-246. [PMID: 21207294 DOI: 10.1007/978-1-61737-985-7_14] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
Metabolomics is a rapidly emerging field of functional genomics research whose aim is the comprehensive analysis of low molecular weight metabolites in a biological sample. Capillary electrophoresis-electrospray ionization-mass spectrometry (CE-ESI-MS) represents a promising hyphenated microseparation platform in metabolomics, since a majority of primary metabolites are intrinsically polar. CE-ESI-MS offers a convenient format for the separation of complex mixtures of cationic, anionic, and/or zwitterionic metabolites, as well as their isobaric/isomeric ions without complicated sample handling. Moreover, online sample preconcentration with desalting is readily integrated during separation prior to ionization, where the migration behavior and ionization response of metabolites can be predicted based on their fundamental physicochemical properties. Herein, we describe recent developments in CE-ESI-MS with emphasis on practical protocols necessary for realizing reliable analyses as applied to targeted metabolite profiling and untargeted metabolomic studies in various biological samples.
Collapse
Affiliation(s)
- Philip Britz-McKibbin
- Department of Chemistry and Chemical Biology, McMaster University, Hamilton, ON, Canada.
| |
Collapse
|
37
|
|
38
|
Maxwell EJ, Zhong X, Zhang H, van Zeijl N, Chen DDY. Decoupling CE and ESI for a more robust interface with MS. Electrophoresis 2010; 31:1130-1137. [DOI: 10.1002/elps.200900517] [Citation(s) in RCA: 129] [Impact Index Per Article: 9.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
39
|
Mokaddem M, Gareil P, Varenne A. Online CIEF-ESI-MS in glycerol-water media with a view to hydrophobic protein applications. Electrophoresis 2010; 30:4040-8. [PMID: 19960468 DOI: 10.1002/elps.200900091] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
A new online coupling of CIEF with ESI-MS has been developed in glycerol-water media. This improved protocol provides: (i) the electric continuity during the whole analysis by a discontinuous filling of the capillary with 60:40 (cm/cm) catholyte/proteins-ampholyte mixture; (ii) the use of an anticonvective medium, i.e. 30:70 glycerol/water, v/v, compatible with MS detection and as an aid to hydrophobic protein solubilization and (iii) the use of unmodified bare fused-silica capillaries, as the glycerol/water medium strongly reduces EOF. Focusing was performed in positive polarity and cathodic mobilization was achieved by both voltage and pressure application. The setup was optimized with respect to analysis time, sensitivity and precision on pI determination. The optimized anolyte and catholyte were composed of 50 mM formic acid/1 mM glutamic acid (pH 2.35) and 100 mM NH(3)/1 mM lysine (pH 10.6), respectively. The effects of ampholyte concentration, focusing time and ESI parameters were presented for model proteins and discussed. This new integrated protocol should be an easy and effective additional tool in the field of proteome analysis, providing a means for the characterization of a large number of hydrophilic and hydrophobic proteins.
Collapse
Affiliation(s)
- Meriem Mokaddem
- Laboratoire de Physicochimie des Electrolytes, Colloïdes et Sciences Analytiques, UMR CNRS-UPMC, Ecole Nationale Supérieure de Chimie de Paris, 75231 Paris, France
| | | | | |
Collapse
|