Taasti VT, Kneepkens E, van der Stoep J, Velders M, Cobben M, Vullings A, Buck J, Visser F, van den Bosch M, Hattu D, Mannens J, 't Ven LI, de Ruysscher D, van Loon J, Peeters S, Unipan M, Rinaldi I. Proton therapy of lung cancer patients - Treatment strategies and clinical experience from a medical physicist's perspective. Phys Med 2025; 130:104890. [PMID: 39799813 DOI: 10.1016/j.ejmp.2024.104890] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/24/2024] [Revised: 11/21/2024] [Accepted: 12/30/2024] [Indexed: 01/15/2025] Open
Abstract
PURPOSE Proton therapy of moving targets is considered a challenge. At Maastro, we started treating lung cancer patients with proton therapy in October 2019. In this work, we summarise the developed treatment strategies and gained clinical experience from a physics point of view. METHODS We report on our clinical approaches to treat lung cancer patients with the Mevion Hyperscan S250i proton machine. We classify lung cancer patients as small movers (tumour movement ≤ 5 mm) or large movers (tumour movement > 5 mm). The preferred beam configuration has evolved over the years of clinical treatment, and currently mostly two or three beam directions are used. All patients are treated with robustly optimised plans (5 mm setup and 3% range uncertainty). Small movers are planned based on a clinical target volume (CTV) with a 3 mm isotropic margin expansion to account for motion, while large movers are planned based on an internal target volume (ITV). All patients are treated in free-breathing. RESULTS Between October 2019 and December 2023, 379 lung cancer patients have been treated, of which 130 were large movers. The adaptation rate was 28%. The median treatment time has been reduced from 30 to 23 min. The mean dose to the heart, oesophagus, and lungs was on average 4.3, 15.4, and 11.0 Gy, respectively. CONCLUSIONS Several treatment planning and workflow improvements have been introduced over the years, resulting in an increase of treatment quality and number of treated patients, as well as reduction of planning and treatment time.
Collapse
Affiliation(s)
- Vicki Trier Taasti
- Department of Radiation Oncology (Maastro), GROW School for Oncology and Reproduction, Maastricht University Medical Centre+, Maastricht, the Netherlands
| | - Esther Kneepkens
- Department of Radiation Oncology (Maastro), GROW School for Oncology and Reproduction, Maastricht University Medical Centre+, Maastricht, the Netherlands
| | - Judith van der Stoep
- Department of Radiation Oncology (Maastro), GROW School for Oncology and Reproduction, Maastricht University Medical Centre+, Maastricht, the Netherlands
| | - Marije Velders
- Department of Radiation Oncology (Maastro), GROW School for Oncology and Reproduction, Maastricht University Medical Centre+, Maastricht, the Netherlands
| | - Maud Cobben
- Department of Radiation Oncology (Maastro), GROW School for Oncology and Reproduction, Maastricht University Medical Centre+, Maastricht, the Netherlands
| | - Anouk Vullings
- Department of Radiation Oncology (Maastro), GROW School for Oncology and Reproduction, Maastricht University Medical Centre+, Maastricht, the Netherlands
| | - Janou Buck
- Department of Radiation Oncology (Maastro), GROW School for Oncology and Reproduction, Maastricht University Medical Centre+, Maastricht, the Netherlands
| | - Femke Visser
- Department of Radiation Oncology (Maastro), GROW School for Oncology and Reproduction, Maastricht University Medical Centre+, Maastricht, the Netherlands
| | - Maud van den Bosch
- Department of Radiation Oncology (Maastro), GROW School for Oncology and Reproduction, Maastricht University Medical Centre+, Maastricht, the Netherlands
| | - Djoya Hattu
- Department of Radiation Oncology (Maastro), GROW School for Oncology and Reproduction, Maastricht University Medical Centre+, Maastricht, the Netherlands
| | - Jolein Mannens
- Department of Radiation Oncology (Maastro), GROW School for Oncology and Reproduction, Maastricht University Medical Centre+, Maastricht, the Netherlands
| | - Lieke In 't Ven
- Department of Radiation Oncology (Maastro), GROW School for Oncology and Reproduction, Maastricht University Medical Centre+, Maastricht, the Netherlands
| | - Dirk de Ruysscher
- Department of Radiation Oncology (Maastro), GROW School for Oncology and Reproduction, Maastricht University Medical Centre+, Maastricht, the Netherlands
| | - Judith van Loon
- Department of Radiation Oncology (Maastro), GROW School for Oncology and Reproduction, Maastricht University Medical Centre+, Maastricht, the Netherlands
| | - Stephanie Peeters
- Department of Radiation Oncology (Maastro), GROW School for Oncology and Reproduction, Maastricht University Medical Centre+, Maastricht, the Netherlands
| | - Mirko Unipan
- Department of Radiation Oncology (Maastro), GROW School for Oncology and Reproduction, Maastricht University Medical Centre+, Maastricht, the Netherlands
| | - Ilaria Rinaldi
- Department of Radiation Oncology (Maastro), GROW School for Oncology and Reproduction, Maastricht University Medical Centre+, Maastricht, the Netherlands.
| |
Collapse
|
2
|
Koh CWY, Lew KS, Wibawa A, Master Z, Yeap PL, Chua CGA, Lee JCL, Tan HQ, Park SY. First clinical experience following the consensus guide for calibrating a proton stopping power ratio curve in a new proton centre. Phys Med 2024; 120:103341. [PMID: 38554639 DOI: 10.1016/j.ejmp.2024.103341] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/22/2023] [Revised: 03/07/2024] [Accepted: 03/25/2024] [Indexed: 04/02/2024] Open
Abstract
BACKGROUND AND PURPOSE This work introduces the first assessment of CT calibration following the ESTRO's consensus guidelines and validating the HLUT through the irradiation of biological material. METHODS Two electron density phantoms were scanned with two CT scanners using two CT scan energies. The stopping power ratio (SPR) and mass density (MD) HLUTs for different CT scan energies were derived using Schneider's and ESTRO's methods. The comparison metric in this work is based on the Water-Equivalent Thickness (WET) difference between the treatment planning system and biological irradiation measurement. The SPR HLUTs were compared between the two calibration methods. To assess the accuracy of using MD HLUT for dose calculation in the treatment planning system, MD vs SPR HLUT was compared. Lastly, the feasibility of using a single SPR HLUT to replace two different energy CT scans was explored. RESULTS The results show a WET difference of less than 3.5% except for the result in the Bone region between Schneider's and ESTRO's methods. Comparing MD and SPR HLUT, the results from MD HLUT show less than a 3.5% difference except for the Bone region. However, the SPR HLUT shows a lower mean absolute percentage difference as compared to MD HLUT between the measured and calculated WET difference. Lastly, it is possible to use a single SPR HLUT for two different CT scan energies since both WET differences are within 3.5%. CONCLUSION This is the first report on calibrating an HLUT following the ESTRO's guidelines. While our result shows incremental improvement in range uncertainty using the ESTRO's guideline, the prescriptional approach of the guideline does promote harmonization of CT calibration protocols between different centres.
Collapse
Affiliation(s)
| | - Kah Seng Lew
- Division of Radiation Oncology, National Cancer Centre Singapore, Singapore; Nanyang Technological University Singapore, Singapore
| | - Andrew Wibawa
- Division of Radiation Oncology, National Cancer Centre Singapore, Singapore
| | - Zubin Master
- Division of Radiation Oncology, National Cancer Centre Singapore, Singapore
| | - Ping Lin Yeap
- Division of Radiation Oncology, National Cancer Centre Singapore, Singapore; Department of Oncology, University of Cambridge, United Kingdom
| | | | - James Cheow Lei Lee
- Division of Radiation Oncology, National Cancer Centre Singapore, Singapore; Nanyang Technological University Singapore, Singapore
| | - Hong Qi Tan
- Division of Radiation Oncology, National Cancer Centre Singapore, Singapore; Oncology Academic Clinical Programme, Duke-NUS Medical School, Singapore.
| | - Sung Yong Park
- Division of Radiation Oncology, National Cancer Centre Singapore, Singapore; Oncology Academic Clinical Programme, Duke-NUS Medical School, Singapore
| |
Collapse
|
3
|
Pettersson E, Thilander-Klang A, Bäck A. Prediction of proton stopping power ratios using dual-energy CT basis material decomposition. Med Phys 2024; 51:881-897. [PMID: 38194501 DOI: 10.1002/mp.16929] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2023] [Revised: 12/04/2023] [Accepted: 12/15/2023] [Indexed: 01/11/2024] Open
Abstract
BACKGROUND Proton radiotherapy treatment plans are currently restricted by the range uncertainties originating from the stopping power ratio (SPR) prediction based on single-energy computed tomography (SECT). Various studies have shown that multi-energy CT (MECT) can reduce the range uncertainties due to medical implant materials and age-related variations in tissue composition. None of these has directly applied the basis material density (MD) images produced by projection-based MECT systems for SPR prediction. PURPOSE To present and evaluate a novel proton SPR prediction method based on MD images from dual-energy CT (DECT), which could reduce the range uncertainties currently associated with proton radiotherapy. METHODS A theoretical basis material decomposition into water and iodine material densities was performed for various pediatric and adult human reference tissues, as well as other non-tissue materials, by minimizing the root-mean-square relative attenuation error in the energy interval from 40 to 140 keV. A model (here called MD-SPR) mapping predicted MDs to theoretically calculated reference SPRs was created with locally weighted scatterplot smoothing (LOWESS) data-fitting. The goodness of fit of the MD-SPR model was evaluated for the included reference tissues. MD images of two electron density phantoms, combined to form a head- and an abdomen-sized phantom setup, were acquired with a clinical projection-based fast-kV switching DECT scanner. The MD images were compared to the theoretically predicted MDs of the tissue surrogates and other non-tissue materials in the phantoms, as well as used for input to the MD-SPR model for generation of SPR images. The SPR images were subsequently compared to theoretical reference SPRs of the materials in the phantoms, as well as to SPR images from a commercial algorithm (DirectSPR, Siemens Healthineers, Forchheim, Germany) using image-based consecutive scan DECT for the same phantom setups. RESULTS The predicted SPRs of the tissue surrogates were similar for MD-SPR and DirectSPR, where the adipose and bone tissue surrogates were within 1% difference to the reference SPRs, while other non-adipose soft tissue surrogates (breast, brain, liver, muscle) were all underestimated by between -0.7% and -1.8%. The SPRs of the non-tissue materials (polymethyl methacrylate (PMMA), polyether ether ketone (PEEK), graphite and Teflon) were within 2.8% for MD-SPR images, compared to 6.8% for DirectSPR. CONCLUSIONS The MD-SPR model performed similar compared to other published methods for the human reference tissues. The SPR prediction for tissue surrogates was similar to DirectSPR and showed potential to improve SPR prediction for non-tissue materials.
Collapse
Affiliation(s)
- Erik Pettersson
- Department of Medical Radiation Sciences, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
- Therapeutic Radiation Physics, Department of Medical Physics and Biomedical Engineering, Sahlgrenska University Hospital, Gothenburg, Sweden
| | - Anne Thilander-Klang
- Department of Medical Radiation Sciences, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
- Diagnostic Radiation Physics, Department of Medical Physics and Biomedical Engineering, Sahlgrenska University Hospital, Gothenburg, Sweden
| | - Anna Bäck
- Department of Medical Radiation Sciences, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
- Therapeutic Radiation Physics, Department of Medical Physics and Biomedical Engineering, Sahlgrenska University Hospital, Gothenburg, Sweden
| |
Collapse
|
4
|
Chang CW, Marants R, Gao Y, Goette M, Scholey JE, Bradley JD, Liu T, Zhou J, Sudhyadhom A, Yang X. Multimodal imaging-based material mass density estimation for proton therapy using supervised deep learning. Br J Radiol 2023; 96:20220907. [PMID: 37660372 PMCID: PMC10646631 DOI: 10.1259/bjr.20220907] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2022] [Revised: 04/25/2023] [Accepted: 08/03/2023] [Indexed: 09/05/2023] Open
Abstract
OBJECTIVE Mapping CT number to material property dominates the proton range uncertainty. This work aims to develop a physics-constrained deep learning-based multimodal imaging (PDMI) framework to integrate physics, deep learning, MRI, and advanced dual-energy CT (DECT) to derive accurate patient mass density maps. METHODS Seven tissue substitute MRI phantoms were used for validation including adipose, brain, muscle, liver, skin, spongiosa, 45% hydroxyapatite (HA) bone. MRI images were acquired using T1 weighted Dixon and T2 weighted short tau inversion recovery sequences. Training inputs are from MRI and twin-beam dual-energy images acquired at 120 kVp with gold/tin filters. The feasibility investigation included an empirical model and four residual networks (ResNet) derived from different training inputs and strategies by PDMI framework. PRN-MR-DE and RN-MR-DE denote ResNet (RN) trained with and without a physics constraint (P) using MRI (MR) and DECT (DE) images. PRN-DE stands for RN trained with a physics constraint using only DE images. A retrospective study using institutional patient data was also conducted to investigate the feasibility of the proposed framework. RESULTS For the tissue surrogate study, PRN-MR-DE, PRN-DE, and RN-MR-DE result in mean mass density errors: -0.72%/2.62%/-3.58% for adipose; -0.03%/-0.61%/-0.18% for muscle; -0.58%/-1.36%/-4.86% for 45% HA bone. The retrospective patient study indicated that PRN-MR-DE predicted the densities of soft tissue and bone within expected intervals based on the literature survey, while PRN-DE generated large density deviations. CONCLUSION The proposed PDMI framework can generate accurate mass density maps using MRI and DECT images. The supervised learning can further enhance model efficacy, making PRN-MR-DE outperform RN-MR-DE. The patient investigation also shows that the framework can potentially improve proton range uncertainty with accurate patient mass density maps. ADVANCES IN KNOWLEDGE PDMI framework is proposed for the first time to inform deep learning models by physics insights and leverage the information from MRI to derive accurate mass density maps.
Collapse
Affiliation(s)
- Chih-Wei Chang
- Department of Radiation Oncology, Winship Cancer Institute, Emory University, Atlanta, Georgia, United States
| | - Raanan Marants
- Department of Radiation Oncology, Brigham & Women’s Hospital/Dana-Farber Cancer Institute/Harvard Medical School, Boston, Massachusetts, United States
| | - Yuan Gao
- Department of Radiation Oncology, Winship Cancer Institute, Emory University, Atlanta, Georgia, United States
| | - Matthew Goette
- Department of Radiation Oncology, Winship Cancer Institute, Emory University, Atlanta, Georgia, United States
| | - Jessica E. Scholey
- Department of Radiation Oncology, The University of California, San Francisco, California, United States
| | - Jeffrey D. Bradley
- Department of Radiation Oncology, University of Pennsylvania, Philadelphia, Pennsylvania, United States
| | - Tian Liu
- Department of Radiation Oncology, Icahn School of Medicine at Mount Sinai, New York, New York, United States
| | - Jun Zhou
- Department of Radiation Oncology, Winship Cancer Institute, Emory University, Atlanta, Georgia, United States
| | - Atchar Sudhyadhom
- Department of Radiation Oncology, Brigham & Women’s Hospital/Dana-Farber Cancer Institute/Harvard Medical School, Boston, Massachusetts, United States
| | - Xiaofeng Yang
- Department of Radiation Oncology, Winship Cancer Institute, Emory University, Atlanta, Georgia, United States
| |
Collapse
|
5
|
Peters N, Trier Taasti V, Ackermann B, Bolsi A, Vallhagen Dahlgren C, Ellerbrock M, Fracchiolla F, Gomà C, Góra J, Cambraia Lopes P, Rinaldi I, Salvo K, Sojat Tarp I, Vai A, Bortfeld T, Lomax A, Richter C, Wohlfahrt P. Consensus guide on CT-based prediction of stopping-power ratio using a Hounsfield look-up table for proton therapy. Radiother Oncol 2023; 184:109675. [PMID: 37084884 PMCID: PMC10351362 DOI: 10.1016/j.radonc.2023.109675] [Citation(s) in RCA: 20] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2022] [Revised: 03/08/2023] [Accepted: 04/10/2023] [Indexed: 04/23/2023]
Abstract
BACKGROUND AND PURPOSE Studies have shown large variations in stopping-power ratio (SPR) prediction from computed tomography (CT) across European proton centres. To standardise this process, a step-by-step guide on specifying a Hounsfield look-up table (HLUT) is presented here. MATERIALS AND METHODS The HLUT specification process is divided into six steps: Phantom setup, CT acquisition, CT number extraction, SPR determination, HLUT specification, and HLUT validation. Appropriate CT phantoms have a head- and body-sized part, with tissue-equivalent inserts in regard to X-ray and proton interactions. CT numbers are extracted from a region-of-interest covering the inner 70% of each insert in-plane and several axial CT slices in scan direction. For optimal HLUT specification, the SPR of phantom inserts is measured in a proton beam and the SPR of tabulated human tissues is computed stoichiometrically at 100 MeV. Including both phantom inserts and tabulated human tissues increases HLUT stability. Piecewise linear regressions are performed between CT numbers and SPRs for four tissue groups (lung, adipose, soft tissue, and bone) and then connected with straight lines. Finally, a thorough but simple validation is performed. RESULTS The best practices and individual challenges are explained comprehensively for each step. A well-defined strategy for specifying the connection points between the individual line segments of the HLUT is presented. The guide was tested exemplarily on three CT scanners from different vendors, proving its feasibility. CONCLUSION The presented step-by-step guide for CT-based HLUT specification with recommendations and examples can contribute to reduce inter-centre variations in SPR prediction.
Collapse
Affiliation(s)
- Nils Peters
- OncoRay - National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Helmholtz-Zentrum Dresden - Rossendorf, Germany; Massachusetts General Hospital and Harvard Medical School, Department of Radiation Oncology, Boston, MA, USA.
| | - Vicki Trier Taasti
- Department of Radiation Oncology (Maastro), GROW School for Oncology and Reproduction, Maastricht University Medical Centre+, Maastricht, The Netherlands.
| | - Benjamin Ackermann
- Heidelberg Ion-Beam Therapy Center (HIT), Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Germany
| | - Alessandra Bolsi
- Center for Proton Therapy, Paul Scherrer Institute, Villigen, Switzerland
| | | | - Malte Ellerbrock
- Heidelberg Ion-Beam Therapy Center (HIT), Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Germany
| | - Francesco Fracchiolla
- Azienda Provinciale per i Servizi Sanitari (APSS) Protontherapy Department, Trento, Italy
| | - Carles Gomà
- Department of Radiation Oncology, Hospital Clínic de Barcelona, Barcelona, Spain
| | - Joanna Góra
- MedAustron Ion Therapy Center, Wiener Neustadt, Austria
| | | | - Ilaria Rinaldi
- Department of Radiation Oncology (Maastro), GROW School for Oncology and Reproduction, Maastricht University Medical Centre+, Maastricht, The Netherlands
| | - Koen Salvo
- AZ Sint-Maarten, Department of Radiotherapy, Mechelen, Belgium
| | - Ivanka Sojat Tarp
- Aarhus University Hospital, Danish Center for Particle Therapy, Aarhus, Denmark
| | - Alessandro Vai
- Radiotherapy Department, Center for National Oncological Hadrontherapy (CNAO), 27100 Pavia, Italy
| | - Thomas Bortfeld
- Massachusetts General Hospital and Harvard Medical School, Department of Radiation Oncology, Boston, MA, USA
| | - Antony Lomax
- Center for Proton Therapy, Paul Scherrer Institute, Villigen, Switzerland
| | - Christian Richter
- OncoRay - National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Helmholtz-Zentrum Dresden - Rossendorf, Germany; Helmholtz-Zentrum Dresden - Rossendorf, Institute of Radiooncology - OncoRay, Dresden, Germany; Department of Radiotherapy and Radiation Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany; German Cancer Consortium (DKTK), partner site Dresden, and German Cancer Research Center (DKFZ), Heidelberg, Germany
| | - Patrick Wohlfahrt
- Massachusetts General Hospital and Harvard Medical School, Department of Radiation Oncology, Boston, MA, USA
| |
Collapse
|
6
|
Yang M, Wohlfahrt P, Shen C, Bouchard H. Dual- and multi-energy CT for particle stopping-power estimation: current state, challenges and potential. Phys Med Biol 2023; 68. [PMID: 36595276 DOI: 10.1088/1361-6560/acabfa] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2022] [Accepted: 12/15/2022] [Indexed: 12/23/2022]
Abstract
Range uncertainty has been a key factor preventing particle radiotherapy from reaching its full physical potential. One of the main contributing sources is the uncertainty in estimating particle stopping power (ρs) within patients. Currently, theρsdistribution in a patient is derived from a single-energy CT (SECT) scan acquired for treatment planning by converting CT number expressed in Hounsfield units (HU) of each voxel toρsusing a Hounsfield look-up table (HLUT), also known as the CT calibration curve. HU andρsshare a linear relationship with electron density but differ in their additional dependence on elemental composition through different physical properties, i.e. effective atomic number and mean excitation energy, respectively. Because of that, the HLUT approach is particularly sensitive to differences in elemental composition between real human tissues and tissue surrogates as well as tissue variations within and among individual patients. The use of dual-energy CT (DECT) forρsprediction has been shown to be effective in reducing the uncertainty inρsestimation compared to SECT. The acquisition of CT data over different x-ray spectra yields additional information on the material elemental composition. Recently, multi-energy CT (MECT) has been explored to deduct material-specific information with higher dimensionality, which has the potential to further improve the accuracy ofρsestimation. Even though various DECT and MECT methods have been proposed and evaluated over the years, these approaches are still only scarcely implemented in routine clinical practice. In this topical review, we aim at accelerating this translation process by providing: (1) a comprehensive review of the existing DECT/MECT methods forρsestimation with their respective strengths and weaknesses; (2) a general review of uncertainties associated with DECT/MECT methods; (3) a general review of different aspects related to clinical implementation of DECT/MECT methods; (4) other potential advanced DECT/MECT applications beyondρsestimation.
Collapse
Affiliation(s)
- Ming Yang
- The University of Texas MD Anderson Cancer Center, Department of Radiation Physics, 1515 Holcombe Blvd Houston, TX 77030, United States of America
| | - Patrick Wohlfahrt
- Massachusetts General Hospital and Harvard Medical School, Department of Radiation Oncology, Boston, MA 02115, United States of America
| | - Chenyang Shen
- University of Texas Southwestern Medical Center, Department of Radiation Oncology, 2280 Inwood Rd Dallas, TX 75235, United States of America
| | - Hugo Bouchard
- Département de physique, Université de Montréal, Complexe des sciences, 1375 Avenue Thérèse-Lavoie-Roux, Montréal, Québec H2V0B3, Canada.,Centre de recherche du Centre hospitalier de l'Université de Montréal, 900 Rue Saint-Denis, Montréal, Québec, H2X 0A9, Canada.,Département de radio-oncologie, Centre hospitalier de l'Université de Montréal, 1051 Rue Sanguinet, Montréal, Québec H2X 3E4, Canada
| |
Collapse
|
7
|
Chang CW, Zhou S, Gao Y, Lin L, Liu T, Bradley JD, Zhang T, Zhou J, Yang X. Validation of a deep learning-based material estimation model for Monte Carlo dose calculation in proton therapy. Phys Med Biol 2022; 67:10.1088/1361-6560/ac9663. [PMID: 36174551 PMCID: PMC9639218 DOI: 10.1088/1361-6560/ac9663] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2022] [Accepted: 09/29/2022] [Indexed: 11/11/2022]
Abstract
Objective. Computed tomography (CT) to material property conversion dominates proton range uncertainty, impacting the quality of proton treatment planning. Physics-based and machine learning-based methods have been investigated to leverage dual-energy CT (DECT) to predict proton ranges. Recent development includes physics-informed deep learning (DL) for material property inference. This paper aims to develop a framework to validate Monte Carlo dose calculation (MCDC) using CT-based material characterization models.Approach.The proposed framework includes two experiments to validatein vivodose and water equivalent thickness (WET) distributions using anthropomorphic and porcine phantoms. Phantoms were irradiated using anteroposterior proton beams, and the exit doses and residual ranges were measured by MatriXX PT and a multi-layer strip ionization chamber. Two pre-trained conventional and physics-informed residual networks (RN/PRN) were used for mass density inference from DECT. Additional two heuristic material conversion models using single-energy CT (SECT) and DECT were implemented for comparisons. The gamma index was used for dose comparisons with criteria of 3%/3 mm (10% dose threshold).Main results. The phantom study showed that MCDC with PRN achieved mean gamma passing rates of 95.9% and 97.8% for the anthropomorphic and porcine phantoms. The rates were 86.0% and 79.7% for MCDC with the empirical DECT model. WET analyses indicated that the mean WET variations between measurement and simulation were -1.66 mm, -2.48 mm, and -0.06 mm for MCDC using a Hounsfield look-up table with SECT and empirical and PRN models with DECT. Validation experiments indicated that MCDC with PRN achieved consistent dose and WET distributions with measurement.Significance. The proposed framework can be used to identify the optimal CT-based material characterization model for MCDC to improve proton range uncertainty. The framework can systematically verify the accuracy of proton treatment planning, and it can potentially be implemented in the treatment room to be instrumental in online adaptive treatment planning.
Collapse
Affiliation(s)
- Chih-Wei Chang
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA 30308
| | - Shuang Zhou
- Department of Radiation Oncology, Physics Division, Washington University in St. Louis School of Medicine, St. Louis, MO 63110
| | - Yuan Gao
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA 30308
| | - Liyong Lin
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA 30308
| | - Tian Liu
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA 30308
| | - Jeffrey D. Bradley
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA 30308
| | - Tiezhi Zhang
- Department of Radiation Oncology, Physics Division, Washington University in St. Louis School of Medicine, St. Louis, MO 63110
| | - Jun Zhou
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA 30308
| | - Xiaofeng Yang
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA 30308
- Department of Biomedical Informatics, Emory University, Atlanta, GA 30308
| |
Collapse
|
8
|
Dedes G, Drosten H, Götz S, Dickmann J, Sarosiek C, Pankuch M, Krah N, Rit S, Bashkirov V, Schulte RW, Johnson RP, Parodi K, DeJongh E, Landry G. Comparative accuracy and resolution assessment of two prototype proton computed tomography scanners. Med Phys 2022; 49:4671-4681. [PMID: 35396739 DOI: 10.1002/mp.15657] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2021] [Revised: 02/14/2022] [Accepted: 03/07/2022] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Improving the accuracy of relative stopping power (RSP) in proton therapy may allow reducing range margins. Proton computed tomography (pCT) has been shown to provide state-of-the-art RSP accuracy estimation, and various scanner prototypes have recently been built. The different approaches used in scanner design are expected to impact spatial resolution and RSP accuracy. PURPOSE The goal of this study was to perform the first direct comparison, in terms of spatial resolution and RSP accuracy, of two pCT prototype scanners installed at the same facility and by using the same image reconstruction algorithm. METHODS A phantom containing cylindrical inserts of known RSP was scanned at the phase-II pCT prototype of the U.S. pCT collaboration and at the commercially oriented ProtonVDA scanner. Following distance-driven binning filtered backprojection reconstruction, the radial edge spread function of high-density inserts was used to estimate the spatial resolution. RSP accuracy was evaluated by the mean absolute percent error (MAPE) over the inserts. No direct imaging dose estimation was possible, which prevented a comparison of the two scanners in terms of RSP noise. RESULTS In terms of RSP accuracy, both scanners achieved the same MAPE of 0.72% when excluding the porous sinus insert from the evaluation. The ProtonVDA scanner reached a better overall MAPE when all inserts and the body of the phantom were accounted for (0.81%), compared to the phase-II scanner (1.14%). The spatial resolution with the phase-II scanner was found to be 0.61 lp/mm, while for the ProtonVDA scanner somewhat lower at 0.46 lp/mm. CONCLUSIONS The comparison between two prototype pCT scanners operated in the same clinical facility showed that they both fulfill the requirement of an RSP accuracy of about 1%. Their spatial resolution performance reflects the different design choices of either a scanner with full tracking capabilities (phase-II) or of a more compact tracker system which only provides the positions of protons but not their directions (ProtonVDA). This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- G Dedes
- Department of Medical Physics, Faculty of Physics, Ludwig-Maximilians-Universität München, Am Coulombwall 1, Garching b. München, 85748, Germany
| | - H Drosten
- Department of Medical Physics, Faculty of Physics, Ludwig-Maximilians-Universität München, Am Coulombwall 1, Garching b. München, 85748, Germany
| | - S Götz
- Department of Medical Physics, Faculty of Physics, Ludwig-Maximilians-Universität München, Am Coulombwall 1, Garching b. München, 85748, Germany
| | - J Dickmann
- Department of Medical Physics, Faculty of Physics, Ludwig-Maximilians-Universität München, Am Coulombwall 1, Garching b. München, 85748, Germany
| | - C Sarosiek
- Department of Physics, Northern Illinois University, 1425 W. Lincoln Highway DeKalb, Illinois, IL, 60115, United States of America
| | - M Pankuch
- Northwestern Medicine Chicago Proton Center, 4455 Weaver Parkway, Warrenville, Illinois, IL, 60555, United States of America
| | - N Krah
- University of Lyon, INSA-Lyon, Université Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1294, LYON, F-69373, France
| | - S Rit
- University of Lyon, INSA-Lyon, Université Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1294, LYON, F-69373, France
| | - V Bashkirov
- Division of Biomedical Engineering Sciences, Loma Linda University, Loma Linda, California, CA 92354, United States of America
| | - R W Schulte
- Division of Biomedical Engineering Sciences, Loma Linda University, Loma Linda, California, CA 92354, United States of America
| | - R P Johnson
- Department of Physics, U.C. Santa Cruz, 1156 High Street Santa Cruz, California, CA, 95064, United States of America
| | - K Parodi
- Department of Medical Physics, Faculty of Physics, Ludwig-Maximilians-Universität München, Am Coulombwall 1, Garching b. München, 85748, Germany
| | - E DeJongh
- ProtonVDA LLC, 1700 Park Street STE 208, Naperville, Illinois, IL, 60563, United States of America
| | - G Landry
- Department of Medical Physics, Faculty of Physics, Ludwig-Maximilians-Universität München, Am Coulombwall 1, Garching b. München, 85748, Germany.,Department of Radiation Oncology, University Hospital, LMU Munich, Munich, 81377, Germany.,German Cancer Consortium (DKTK), Munich, 81377, Germany
| |
Collapse
|
9
|
Reduction of clinical safety margins in proton therapy enabled by the clinical implementation of dual-energy CT for direct stopping-power prediction. Radiother Oncol 2021; 166:71-78. [PMID: 34774653 DOI: 10.1016/j.radonc.2021.11.002] [Citation(s) in RCA: 50] [Impact Index Per Article: 12.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2021] [Revised: 08/24/2021] [Accepted: 11/02/2021] [Indexed: 12/31/2022]
Abstract
PURPOSE To quantifiy the range uncertainty in proton treatment planning using dual-energy computed tomography (DECT) for a direct stopping-power prediction (DirectSPR) algorithm and its clinical implementation. METHODS AND MATERIALS To assess the overall uncertainty in stopping-power ratio (SPR) prediction of a DirectSPR implementation calibrated for different patient geometries, the influencing factors were categorized in imaging, modeling as well as others. The respective SPR uncertainty was quantified for lung, soft tissue and bone and translated into range uncertainty for several tumor types. The amount of healthy tissue spared was quantified for 250 patients treated with DirectSPR and the dosimetric impact was evaluated exemplarily for a representative brain-tumor patient. RESULTS For bone, soft tissue and lung, an SPR uncertainty (1σ) of 1.6%, 1.3% and 1.3% was determined for DirectSPR, respectively. This allowed for a reduction of the clinically applied range uncertainty from currently (3.5% + 2 mm) to (1.7% + 2 mm) for brain-tumor and (2.0% + 2 mm) for prostate-cancer patients. The 150 brain-tumor and 100 prostate-cancer patients treated using DirectSPR benefitted from sparing on average 2.6 mm and 4.4 mm of healthy tissue in beam direction, respectively. In the representative patient case, dose reduction in organs at risk close to the target volume was achieved, with a mean dose reduction of up to 16% in the brainstem. Patient-specific DECT-based treatment planning with reduced safety margins was successfully introduced into clinical routine. CONCLUSIONS A substantial increase in range prediction accuracy in clinical proton treatment planning was achieved by patient-specific DECT-based SPR prediction. For the first time, a relevant imaging-based reduction of range prediction uncertainty on a 2% level has been achieved.
Collapse
|
10
|
Bäumer C, Bäcker CM, Conti M, Fragoso Costa P, Herrmann K, Kazek SL, Jentzen W, Panin V, Siegel S, Teimoorisichani M, Wulff J, Timmermann B. Can a ToF-PET photon attenuation reconstruction test stopping-power estimations in proton therapy? A phantom study. Phys Med Biol 2021; 66. [PMID: 34534971 DOI: 10.1088/1361-6560/ac27b5] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2021] [Accepted: 09/13/2021] [Indexed: 01/19/2023]
Abstract
Objective. The aim of the phantom study was to validate and to improve the computed tomography (CT) images used for the dose computation in proton therapy. It was tested, if the joint reconstruction of activity and attenuation images of time-of-flight PET (ToF-PET) scans could improve the estimation of the proton stopping-power.Approach. The attenuation images, i.e. CT images with 511 keV gamma-rays (γCTs), were jointly reconstructed with activity maps from ToF-PET scans. Theβ+activity was produced with FDG and in a separate experiment with proton-induced radioactivation. The phantoms contained slabs of tissue substitutes. The use of theγCTs for the prediction of the beam stopping in proton therapy was based on a linear relationship between theγ-ray attenuation, the electron density, and the stopping-power of fast protons.Main results. The FDG based experiment showed sufficient linearity to detect a bias of bony tissue in the heuristic look-up table, which maps between x-ray CT images and proton stopping-power.γCTs can be used for dose computation, if the electron density of one type of tissue is provided as a scaling factor. A possible limitation is imposed by the spatial resolution, which is inferior by a factor of 2.5 compared to the one of the x-ray CT.γCTs can also be derived from off-line, ToF-PET scans subsequent to the application of a proton field with a hypofractionated dose level.Significance. γCTs are a viable tool to support the estimation of proton stopping with radiotracer-based ToF-PET data from diagnosis or staging. This could be of higher potential relevance in MRI-guided proton therapy.γCTs could form an alternative approach to make use of in-beam or off-line PET scans of proton-inducedβ+activity with possible clinical limitations due to the low number of coincidence counts.
Collapse
Affiliation(s)
- C Bäumer
- West German Proton Therapy Centre Essen, Am Mühlenbach 1, Essen, Germany.,University Hospital Essen, Hufelandstr. 55, Essen, Germany.,West German Cancer Center (WTZ), Hufelandstr. 55, Essen, Germany.,German Cancer Consortium (DKTK), Heidelberg, Germany.,TU Dortmund University, Department of Physics, Otto-Hahn-Str. 4a, Dortmund, Germany
| | - C M Bäcker
- West German Proton Therapy Centre Essen, Am Mühlenbach 1, Essen, Germany.,University Hospital Essen, Hufelandstr. 55, Essen, Germany.,West German Cancer Center (WTZ), Hufelandstr. 55, Essen, Germany.,TU Dortmund University, Department of Physics, Otto-Hahn-Str. 4a, Dortmund, Germany
| | - M Conti
- Siemens Medical Solutions USA Inc., Knoxville, Tennessee, United States of America
| | - P Fragoso Costa
- University Hospital Essen, Hufelandstr. 55, Essen, Germany.,University Hospital Essen, Clinic for Nuclear Medicine, Hufelandstr. 55, Essen, Germany
| | - K Herrmann
- University Hospital Essen, Hufelandstr. 55, Essen, Germany.,German Cancer Consortium (DKTK), Heidelberg, Germany.,University Hospital Essen, Clinic for Nuclear Medicine, Hufelandstr. 55, Essen, Germany
| | - S L Kazek
- University Hospital Essen, Hufelandstr. 55, Essen, Germany.,University Hospital Essen, Clinic for Nuclear Medicine, Hufelandstr. 55, Essen, Germany
| | - W Jentzen
- University Hospital Essen, Hufelandstr. 55, Essen, Germany.,University Hospital Essen, Clinic for Nuclear Medicine, Hufelandstr. 55, Essen, Germany
| | - V Panin
- Siemens Medical Solutions USA Inc., Knoxville, Tennessee, United States of America
| | - S Siegel
- Siemens Medical Solutions USA Inc., Knoxville, Tennessee, United States of America
| | - M Teimoorisichani
- Siemens Medical Solutions USA Inc., Knoxville, Tennessee, United States of America
| | - J Wulff
- West German Proton Therapy Centre Essen, Am Mühlenbach 1, Essen, Germany.,University Hospital Essen, Hufelandstr. 55, Essen, Germany.,West German Cancer Center (WTZ), Hufelandstr. 55, Essen, Germany
| | - B Timmermann
- West German Proton Therapy Centre Essen, Am Mühlenbach 1, Essen, Germany.,University Hospital Essen, Hufelandstr. 55, Essen, Germany.,West German Cancer Center (WTZ), Hufelandstr. 55, Essen, Germany.,German Cancer Consortium (DKTK), Heidelberg, Germany.,University Hospital Essen, Department of Particle Therapy, Hufelandstr. 55, Essen, Germany
| |
Collapse
|
11
|
Peters N, Wohlfahrt P, Dahlgren CV, de Marzi L, Ellerbrock M, Fracchiolla F, Free J, Gomà C, Góra J, Jensen MF, Kajdrowicz T, Mackay R, Molinelli S, Rinaldi I, Rompokos V, Siewert D, van der Tol P, Vermeren X, Nyström H, Lomax A, Richter C. Experimental assessment of inter-centre variation in stopping-power and range prediction in particle therapy. Radiother Oncol 2021; 163:7-13. [PMID: 34329653 DOI: 10.1016/j.radonc.2021.07.019] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2021] [Revised: 07/01/2021] [Accepted: 07/19/2021] [Indexed: 12/13/2022]
Abstract
PURPOSE Experimental assessment of inter-centre variation and absolute accuracy of stopping-power-ratio (SPR) prediction within 17 particle therapy centres of the European Particle Therapy Network. MATERIAL AND METHODS A head and body phantom with seventeen tissue-equivalent materials were scanned consecutively at the participating centres using their individual clinical CT scan protocol and translated into SPR with their in-house CT-number-to-SPR conversion. Inter-centre variation and absolute accuracy in SPR prediction were quantified for three tissue groups: lung, soft tissues and bones. The integral effect on range prediction for typical clinical beams traversing different tissues was determined for representative beam paths for the treatment of primary brain tumours as well as lung and prostate cancer. RESULTS An inter-centre variation in SPR prediction (2σ) of 8.7%, 6.3% and 1.5% relative to water was determined for bone, lung and soft-tissue surrogates in the head setup, respectively. Slightly smaller variations were observed in the body phantom (6.2%, 3.1%, 1.3%). This translated into inter-centre variation of integral range prediction (2σ) of 2.9%, 2.6% and 1.3% for typical beam paths of prostate-, lung- and primary brain-tumour treatments, respectively. The absolute error in range exceeded 2% in every fourth participating centre. The consideration of beam hardening and the execution of an independent HLUT validation had a positive effect, on average. CONCLUSION The large inter-centre variations in SPR and range prediction justify the currently clinically used margins accounting for range uncertainty, which are of the same magnitude as the inter-centre variation. This study underlines the necessity of higher standardisation in CT-number-to-SPR conversion.
Collapse
Affiliation(s)
- Nils Peters
- OncoRay - National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Helmholtz-Zentrum Dresden - Rossendorf, Dresden, Germany; Helmholtz-Zentrum Dresden - Rossendorf, Institute of Radiooncology - OncoRay, Dresden, Germany.
| | - Patrick Wohlfahrt
- OncoRay - National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Helmholtz-Zentrum Dresden - Rossendorf, Dresden, Germany; Helmholtz-Zentrum Dresden - Rossendorf, Institute of Radiooncology - OncoRay, Dresden, Germany
| | | | - Ludovic de Marzi
- Institut Curie, PSL Research University, University Paris Saclay, LITO, Orsay, France; Institut Curie, PSL Research University, Radiation Oncology Department, Proton Therapy Centre, Centre Universitaire, Orsay, France
| | - Malte Ellerbrock
- Heidelberg Ion-Beam Therapy Center (HIT), Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Germany
| | | | - Jeffrey Free
- University of Groningen, University Medical Center Groningen, Department of Radiation Oncology, Groningen, The Netherlands
| | - Carles Gomà
- KU Leuven, Department of Oncology, Laboratory of Experimental Radiotherapy, Leuven, Belgium
| | - Joanna Góra
- EBG Medaustron GmbH, Wiener Neustadt, Austria
| | | | - Tomasz Kajdrowicz
- Institute of Nuclear Physics - Polish Academy of Sciences, Krakow, Poland
| | - Ranald Mackay
- University of Manchester - Faculty of Life Sciences, Manchester, United Kingdom
| | | | - Ilaria Rinaldi
- Department of Radiation Oncology (Maastro), GROW School for Oncology, Maastricht University Medical Centre, Maastricht, The Netherlands
| | | | | | | | - Xavier Vermeren
- Westdeutsches Protonentherapiezentrum Essen, Universitätsklinkum Essen, Germany
| | | | | | - Christian Richter
- OncoRay - National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Helmholtz-Zentrum Dresden - Rossendorf, Dresden, Germany; Helmholtz-Zentrum Dresden - Rossendorf, Institute of Radiooncology - OncoRay, Dresden, Germany; Department of Radiotherapy and Radiation Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Germany; German Cancer Consortium (DKTK), partner site Dresden, and German Cancer Research Center (DKFZ), Heidelberg, Germany
| |
Collapse
|
12
|
Berthold J, Khamfongkhruea C, Petzoldt J, Thiele J, Hölscher T, Wohlfahrt P, Peters N, Jost A, Hofmann C, Janssens G, Smeets J, Richter C. First-In-Human Validation of CT-Based Proton Range Prediction Using Prompt Gamma Imaging in Prostate Cancer Treatments. Int J Radiat Oncol Biol Phys 2021; 111:1033-1043. [PMID: 34229052 DOI: 10.1016/j.ijrobp.2021.06.036] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2021] [Revised: 05/20/2021] [Accepted: 06/23/2021] [Indexed: 12/11/2022]
Abstract
PURPOSE Uncertainty in computed tomography (CT)-based range prediction substantially impairs the accuracy of proton therapy. Direct determination of the stopping-power ratio (SPR) from dual-energy CT (DECT) has been proposed (DirectSPR), and initial validation studies in phantoms and biological tissues have proven a high accuracy. However, a thorough validation of range prediction in patients has not yet been achieved by any means. Here, we present the first systematic validation of CT-based proton range prediction in patients using prompt gamma imaging (PGI). METHODS AND MATERIALS A PGI slit camera system with improved positioning accuracy, using a floor-based docking station, was used. Its overall uncertainty for range prediction validation was determined experimentally with both x-ray and beam measurements. The accuracy of range prediction in patients was determined from clinical PGI measurements during hypofractionated treatment of 5 patients with prostate cancer - in total 30 fractions with in-room control-CTs. For each pencil-beam-scanning spot, the range shift was obtained by comparing the PGI measurement to a control-CT-based PGI simulation. Three different SPR prediction approaches were applied in simulations: a standard CT-number-to-SPR conversion (Hounsfield look-up table [HLUT]), an adapted HLUT (DECT optimized), and DirectSPR. The spot-wise weighted mean range shift from all spots served as a measure for the accuracy of the respective range prediction approach. RESULTS A mean range prediction accuracy of 0.0% ± 0.5%, 0.3% ± 0.4%, and 1.8% ± 0.4% was obtained for DirectSPR, adapted HLUT, and standard HLUT, respectively. The overall validation uncertainty of the second-generation PGI slit camera is about 1 mm (2σ) for all approaches, which is smaller than the range prediction uncertainty for deep-seated tumors. CONCLUSIONS For the first time, range prediction accuracy was assessed in clinical routine using PGI range verification in prostate cancer treatments. Both DECT-derived range prediction approaches agree well with the measured proton range from PGI verification, whereas the standard HLUT approach differs relevantly. These results endorse the recent reduction of clinical safety margins in DirectSPR-based treatment planning in our institution.
Collapse
Affiliation(s)
- Jonathan Berthold
- OncoRay - National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Helmholtz-Zentrum Dresden - Rossendorf, Dresden, Germany; Helmholtz-Zentrum Dresden - Rossendorf, Institute of Radiooncology - OncoRay, Dresden, Germany.
| | - Chirasak Khamfongkhruea
- OncoRay - National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Helmholtz-Zentrum Dresden - Rossendorf, Dresden, Germany; Faculty of Medicine and Public Health, HRH Princess Chulabhorn College of Medical Science, Chulabhorn Royal Academy, Bangkok, Thailand
| | | | - Julia Thiele
- Department of Radiotherapy and Radiation Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany
| | - Tobias Hölscher
- Department of Radiotherapy and Radiation Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany
| | - Patrick Wohlfahrt
- OncoRay - National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Helmholtz-Zentrum Dresden - Rossendorf, Dresden, Germany; Helmholtz-Zentrum Dresden - Rossendorf, Institute of Radiooncology - OncoRay, Dresden, Germany
| | - Nils Peters
- OncoRay - National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Helmholtz-Zentrum Dresden - Rossendorf, Dresden, Germany; Helmholtz-Zentrum Dresden - Rossendorf, Institute of Radiooncology - OncoRay, Dresden, Germany
| | - Angelina Jost
- OncoRay - National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Helmholtz-Zentrum Dresden - Rossendorf, Dresden, Germany; Beuth Hochschule für Technik, Berlin, Germany
| | | | | | | | - Christian Richter
- OncoRay - National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Helmholtz-Zentrum Dresden - Rossendorf, Dresden, Germany; Helmholtz-Zentrum Dresden - Rossendorf, Institute of Radiooncology - OncoRay, Dresden, Germany; Department of Radiotherapy and Radiation Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany; German Cancer Consortium (DKTK), partner site Dresden, Germany and German Cancer Research Center (DKFZ), Heidelberg, Germany
| |
Collapse
|
13
|
Kassaee A, Cheng C, Yin L, Zou W, Li T, Lin A, Swisher-McClure S, Lukens JN, Lustig RA, O'Reilly S, Dong L, Ms RH, Teo BKK. Dual-Energy Computed Tomography Proton-Dose Calculation with Scripting and Modified Hounsfield Units. Int J Part Ther 2021; 8:62-72. [PMID: 34285936 PMCID: PMC8270086 DOI: 10.14338/ijpt-20-00075.1] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2020] [Accepted: 02/19/2021] [Indexed: 11/21/2022] Open
Abstract
Purpose To describe an implementation of dual-energy computed tomography (DECT) for calculation of proton stopping-power ratios (SPRs) in a commercial treatment-planning system. The process for validation and the workflow for safe deployment of DECT is described, using single-energy computed tomography (SECT) as a safety check for DECT dose calculation. Materials and Methods The DECT images were acquired at 80 kVp and 140 kVp and were processed with computed tomography scanner software to derive the electron density and effective atomic number images. Reference SPRs of tissue-equivalent plugs from Gammex (Middleton, Wisconsin) and CIRS (Computerized Imaging Reference Systems, Norfolk, Virginia) electron density phantoms were used for validation and comparison of SECT versus DECT calculated through the Eclipse treatment planning system (Varian Medical Systems, Palo Alto, California) application programming interface scripting tool. An in-house software was also used to create DECT SPR computed tomography images for comparison with the script output. In the workflow, using the Eclipse system application programming interface script, clinical plans were optimized with the SECT image set and then forward-calculated with the DECT SPR for the final dose distribution. In a second workflow, the plans were optimized using DECT SPR with reduced range-uncertainty margins. Results For the Gammex phantom, the root mean square error in SPR was 1.08% for DECT versus 2.29% for SECT for 10 tissue-surrogates, excluding the lung. For the CIRS Phantom, the corresponding results were 0.74% and 2.27%. When evaluating the head and neck plan, DECT optimization with 2% range-uncertainty margins achieved a small reduction in organ-at-risk doses compared with that of SECT plans with 3.5% range-uncertainty margins. For the liver case, DECT was used to identify and correct the lipiodol SPR in the SECT plan. Conclusion It is feasible to use DECT for proton-dose calculation in a commercial treatment planning system in a safe manner. The range margins can be reduced to 2% in some sites, including the head and neck.
Collapse
Affiliation(s)
- Anthony Kassaee
- Department of Radiation Oncology, University of Pennsylvania, Philadelphia, PA, USA
| | - Chingyun Cheng
- Department of Radiation Oncology at Rutgers Cancer Institute of New Jersey, New Brunswick, NJ, USA
| | - Lingshu Yin
- Department of Radiation Oncology, University of Pennsylvania, Philadelphia, PA, USA
| | - Wei Zou
- Department of Radiation Oncology, University of Pennsylvania, Philadelphia, PA, USA
| | - Taoran Li
- Department of Radiation Oncology, University of Pennsylvania, Philadelphia, PA, USA
| | - Alexander Lin
- Department of Radiation Oncology, University of Pennsylvania, Philadelphia, PA, USA
| | | | - John N Lukens
- Department of Radiation Oncology, University of Pennsylvania, Philadelphia, PA, USA
| | - Robert A Lustig
- Department of Radiation Oncology, University of Pennsylvania, Philadelphia, PA, USA
| | - Shannon O'Reilly
- Department of Radiation Oncology, University of Pennsylvania, Philadelphia, PA, USA
| | - Lei Dong
- Department of Radiation Oncology, University of Pennsylvania, Philadelphia, PA, USA
| | | | - Boon-Keng Kevin Teo
- Department of Radiation Oncology, University of Pennsylvania, Philadelphia, PA, USA
| |
Collapse
|
14
|
Wang T, Lei Y, Roper J, Ghavidel B, Beitler JJ, McDonald M, Curran WJ, Liu T, Yang X. Head and neck multi-organ segmentation on dual-energy CT using dual pyramid convolutional neural networks. Phys Med Biol 2021; 66:10.1088/1361-6560/abfce2. [PMID: 33915524 PMCID: PMC11747937 DOI: 10.1088/1361-6560/abfce2] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2020] [Accepted: 04/29/2021] [Indexed: 11/11/2022]
Abstract
Organ delineation is crucial to diagnosis and therapy, while it is also labor-intensive and observer-dependent. Dual energy CT (DECT) provides additional image contrast than conventional single energy CT (SECT), which may facilitate automatic organ segmentation. This work aims to develop an automatic multi-organ segmentation approach using deep learning for head-and-neck region on DECT. We proposed a mask scoring regional convolutional neural network (R-CNN) where comprehensive features are firstly learnt from two independent pyramid networks and are then combined via deep attention strategy to highlight the informative ones extracted from both two channels of low and high energy CT. To perform multi-organ segmentation and avoid misclassification, a mask scoring subnetwork was integrated into the Mask R-CNN framework to build the correlation between the class of potential detected organ's region-of-interest (ROI) and the shape of that organ's segmentation within that ROI. We evaluated our model on DECT images from 127 head-and-neck cancer patients (66 training, 61 testing) with manual contours of 19 organs as training target and ground truth. For large- and mid-sized organs such as brain and parotid, the proposed method successfully achieved average Dice similarity coefficient (DSC) larger than 0.8. For small-sized organs with very low contrast such as chiasm, cochlea, lens and optic nerves, the DSCs ranged between around 0.5 and 0.8. With the proposed method, using DECT images outperforms using SECT in almost all 19 organs with statistical significance in DSC (p<0.05). Meanwhile, by using the DECT, the proposed method is also significantly superior to a recently developed FCN-based method in most of organs in terms of DSC and the 95th percentile Hausdorff distance. Quantitative results demonstrated the feasibility of the proposed method, the superiority of using DECT to SECT, and the advantage of the proposed R-CNN over FCN on the head-and-neck patient study. The proposed method has the potential to facilitate the current head-and-neck cancer radiation therapy workflow in treatment planning.
Collapse
Affiliation(s)
- Tonghe Wang
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA 30322, United States of America
| | - Yang Lei
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA 30322, United States of America
| | - Justin Roper
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA 30322, United States of America
| | - Beth Ghavidel
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA 30322, United States of America
| | - Jonathan J Beitler
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA 30322, United States of America
| | - Mark McDonald
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA 30322, United States of America
| | - Walter J Curran
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA 30322, United States of America
| | - Tian Liu
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA 30322, United States of America
| | - Xiaofeng Yang
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA 30322, United States of America
| |
Collapse
|
15
|
Farace P, Tommasino F, Righetto R, Fracchiolla F, Scaringella M, Bruzzi M, Civinini C. Technical Note: CT calibration for proton treatment planning by cross-calibration with proton CT data. Med Phys 2021; 48:1349-1355. [PMID: 33382083 DOI: 10.1002/mp.14698] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2020] [Revised: 11/30/2020] [Accepted: 12/23/2020] [Indexed: 12/31/2022] Open
Abstract
PURPOSE This study explores the possibility of a new method for x-ray computed tomography (CT) calibration by means of cross-calibration with proton CT (pCT) data. The proposed method aims at a more accurate conversion of CT Hounsfield Units (HU) into proton stopping power ratio (SPR) relative to water to be used in proton-therapy treatment planning. METHODS X-ray CT scan was acquired on a synthetic anthropomorphic phantom, composed of different tissue equivalent materials (TEMs). A pCT apparatus was instead adopted to obtain a reference three-dimensional distribution of the phantom's SPR values. After rigid registration, the x-ray CT was artificially blurred to the same resolution of pCT. Then a scatter plot showing voxel-by-voxel SPR values as a function of HU was employed to link the two measurements and thus obtaining a cross-calibrated x-ray CT calibration curve. The cross-calibration was tested at treatment planning system and then compared with a conventional calibration based on exactly the same TEMs constituting the anthropomorphic phantom. RESULTS Cross-calibration provided an accurate SPR mapping, better than by conventional TEMs calibration. The dose distribution of single beams optimized on the reference SPR map was recomputed on cross-calibrated CT, showing, with respect to conventional calibration, minor deviation at the dose fall-off (lower than 1%). CONCLUSIONS The presented data demonstrated that, by means of reference pCT data, a heterogeneous phantom can be used for CT calibration, paving the way to the use of biological samples, with their accurate description of patients' tissues. This overcomes the limitations of conventional CT calibration requiring homogenous samples, only available by synthetic TEMs, which fail in accurately mimicking the properties of biological tissues. Once a heterogeneous biological sample is provided with its corresponding reference SPR maps, a cross-calibration procedure could be adopted by other PT centers, even when not equipped with a pCT system.
Collapse
Affiliation(s)
- Paolo Farace
- Protontherapy Unit, Hospital of Trento, Azienda Provinciale per i Servizi Sanitari (APSS), Trento, Italy.,Istituto Nazionale di Fisica Nucleare TIFPA, via Sommarive, 14, Trento, Italy
| | - Francesco Tommasino
- Istituto Nazionale di Fisica Nucleare TIFPA, via Sommarive, 14, Trento, Italy.,Department of Physics, University of Trento, via Sommarive, 14, Trento, Italy
| | - Roberto Righetto
- Protontherapy Unit, Hospital of Trento, Azienda Provinciale per i Servizi Sanitari (APSS), Trento, Italy.,Istituto Nazionale di Fisica Nucleare TIFPA, via Sommarive, 14, Trento, Italy
| | - Francesco Fracchiolla
- Protontherapy Unit, Hospital of Trento, Azienda Provinciale per i Servizi Sanitari (APSS), Trento, Italy.,Istituto Nazionale di Fisica Nucleare TIFPA, via Sommarive, 14, Trento, Italy
| | - Monica Scaringella
- Istituto Nazionale di Fisica Nucleare sezione di Firenze, Via G. Sansone 1, Sesto Fiorentino, Italy
| | - Mara Bruzzi
- Istituto Nazionale di Fisica Nucleare sezione di Firenze, Via G. Sansone 1, Sesto Fiorentino, Italy.,Dipartimento di Fisica e Astronomia, Università degli Studi di Firenze, via G. Sansone 1, Sesto Fiorentino, Italy
| | - Carlo Civinini
- Istituto Nazionale di Fisica Nucleare sezione di Firenze, Via G. Sansone 1, Sesto Fiorentino, Italy
| |
Collapse
|
16
|
Hahn C, Eulitz J, Peters N, Wohlfahrt P, Enghardt W, Richter C, Lühr A. Impact of range uncertainty on clinical distributions of linear energy transfer and biological effectiveness in proton therapy. Med Phys 2020; 47:6151-6162. [PMID: 33118161 DOI: 10.1002/mp.14560] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2020] [Revised: 10/01/2020] [Accepted: 10/20/2020] [Indexed: 12/14/2022] Open
Abstract
PURPOSE Increased radiation response after proton irradiation, such as late radiation-induced toxicity, is determined by high dose and elevated linear energy transfer (LET). Steep dose-averaged LET (LETd ) gradients and elevated LETd occur at the end of proton range and might be particularly sensitive to uncertainties in range prediction. Therefore, this study quantified LETd distributions and the impact of range uncertainty in robust dose-optimized proton treatment plans and assessed the biological effect in normal tissues and tumors of patients. METHODS For each of six cancer patients (two brain, head-and-neck, and prostate), two nominal treatment plans were robustly dose optimized using single- and multi-field optimization, respectively. For each plan, two additional scenarios with ±3.5% range deviation relative to the nominal plan were derived by global rescaling of stopping-power ratios. Dose and LETd distributions were calculated for each scenario using the beam parameters of the corresponding nominal plan. The variability in relative biological effectiveness (RBE) and probability of late radiation-induced brain toxicity (PIC ) was assessed. RESULTS The optimization technique (single- vs multi-field) had a negligible impact on the LETd distributions in the clinical target volume (CTV) and in most organs at risk (OARs). LETd distributions in the CTV were rather homogeneous with arithmetic mean of LETd below 3.2 keV/µm and robust against range deviations. The RBE variability within the CTV induced by range uncertainty was small (≤0.05, 95% confidence interval). In OARs, LETd hotspots (>7 keV/µm) occurred and LETd distributions were inhomogeneous and sensitive to range deviations. LETd hotspots and the impact of range deviations were most prominent in OARs of brain tumor patients which translated in RBE values exceeding 1.1 in all brain OARs. The near-maximum predicted PIC in healthy brain tissue of brain tumor patients was smaller than 5% and occurred adjacent to the CTV. Range deviations induced absolute differences in PIC up to 1.2%. CONCLUSIONS Robust dose optimization generates LETd distributions in the target volume robust against range deviations. The current findings support using a constant RBE within the CTV. The impact of range deviations on the considered probability of late radiation-induced toxicity in brain tissue was limited for robust dose-optimized treatment plans. Incorporation of LETd in robust optimization frameworks may further reduce uncertainty related to the RBE-weighted dose estimation in normal tissues.
Collapse
Affiliation(s)
- Christian Hahn
- OncoRay - National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Helmholtz-Zentrum Dresden-Rossendorf, Dresden, Germany.,Department of Radiotherapy and Radiation Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany.,Department of Medical Physics and Radiotherapy, Faculty of Physics, TU Dortmund University, Dortmund, Germany
| | - Jan Eulitz
- OncoRay - National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Helmholtz-Zentrum Dresden-Rossendorf, Dresden, Germany.,Department of Radiotherapy and Radiation Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany.,Helmholtz-Zentrum Dresden-Rossendorf, Institute of Radiooncology - OncoRay, Dresden, Germany
| | - Nils Peters
- OncoRay - National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Helmholtz-Zentrum Dresden-Rossendorf, Dresden, Germany.,Helmholtz-Zentrum Dresden-Rossendorf, Institute of Radiooncology - OncoRay, Dresden, Germany
| | - Patrick Wohlfahrt
- Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, USA
| | - Wolfgang Enghardt
- OncoRay - National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Helmholtz-Zentrum Dresden-Rossendorf, Dresden, Germany.,Department of Radiotherapy and Radiation Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany.,Helmholtz-Zentrum Dresden-Rossendorf, Institute of Radiooncology - OncoRay, Dresden, Germany.,German Cancer Consortium (DKTK), Partner Site Dresden, and German Cancer Research Center (DKFZ), Heidelberg, Germany
| | - Christian Richter
- OncoRay - National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Helmholtz-Zentrum Dresden-Rossendorf, Dresden, Germany.,Department of Radiotherapy and Radiation Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany.,Helmholtz-Zentrum Dresden-Rossendorf, Institute of Radiooncology - OncoRay, Dresden, Germany.,German Cancer Consortium (DKTK), Partner Site Dresden, and German Cancer Research Center (DKFZ), Heidelberg, Germany
| | - Armin Lühr
- OncoRay - National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Helmholtz-Zentrum Dresden-Rossendorf, Dresden, Germany.,Department of Medical Physics and Radiotherapy, Faculty of Physics, TU Dortmund University, Dortmund, Germany.,Helmholtz-Zentrum Dresden-Rossendorf, Institute of Radiooncology - OncoRay, Dresden, Germany.,German Cancer Consortium (DKTK), Partner Site Dresden, and German Cancer Research Center (DKFZ), Heidelberg, Germany
| |
Collapse
|
17
|
Wohlfahrt P, Richter C. Status and innovations in pre-treatment CT imaging for proton therapy. Br J Radiol 2020; 93:20190590. [PMID: 31642709 PMCID: PMC7066941 DOI: 10.1259/bjr.20190590] [Citation(s) in RCA: 39] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2019] [Revised: 10/04/2019] [Accepted: 10/21/2019] [Indexed: 12/19/2022] Open
Abstract
Pre-treatment CT imaging is a topic of growing importance in particle therapy. Improvements in the accuracy of stopping-power prediction are demanded to allow for a dose conformality that is not inferior to state-of-the-art image-guided photon therapy. Although range uncertainty has been kept practically constant over the last decades, recent technological and methodological developments, like the clinical application of dual-energy CT, have been introduced or arise at least on the horizon to improve the accuracy and precision of range prediction. This review gives an overview of the current status, summarizes the innovations in dual-energy CT and its potential impact on the field as well as potential alternative technologies for stopping-power prediction.
Collapse
Affiliation(s)
- Patrick Wohlfahrt
- Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA
| | | |
Collapse
|