Otani T, Sekine T, Sato Y, Alves EC, Wada S. An Eulerian formulation for the computational modeling of phase-contrast MRI. Magn Reson Med 2024. [PMID: 39270130 DOI: 10.1002/mrm.30302] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2024] [Revised: 08/25/2024] [Accepted: 08/29/2024] [Indexed: 09/15/2024]
Abstract
PURPOSE Computational simulation of phase-contrast MRI (PC-MRI) is an attractive way to physically interpret properties and errors in MRI-reconstructed flow velocity fields. Recent studies have developed PC-MRI simulators that solve the Bloch equation, with the magnetization transport being modeled using a Lagrangian approach. Because this method expresses the magnetization as spatial distribution of particles, influences of particle densities and their spatial uniformities on numerical accuracy are well known. This study developed an alternative method for PC-MRI modeling using an Eulerian approach in which the magnetization is expressed as a spatially smooth continuous function. METHODS The magnetization motion was described using the Bloch equation with an advection term and computed on a fixed grid using a finite difference method, and k-space sampling was implemented using the spoiled gradient echo sequence. PC-MRI scans of a fully developed flow in straight and stenosed cylinders were acquired to provide numerical examples. RESULTS Reconstructed flow in a straight cylinder showed excellent agreement with input velocity profiles and mean errors were less than 0.5% of the maximum velocity. Numerical cases of flow in a stenosed cylinder successfully demonstrated the velocity profiles, with displacement artifacts being dependent on scan parameters and intravoxel dephasing due to flow disturbances. These results were in good agreement with those obtained using the Lagrangian approach with a sufficient particle density. CONCLUSION The feasibility of the Eulerian approach to PC-MRI modeling was successfully demonstrated.
Collapse
Affiliation(s)
- Tomohiro Otani
- Department of Mechanical Science and Bioengineering, Osaka University Graduate School of Engineering Science, Osaka, Japan
| | - Tetsuro Sekine
- Department of Radiology, Nippon Medical School Musashi-Kosugi Hospital, Kanagawa, Japan
| | - Yu Sato
- Department of Mechanical Science and Bioengineering, Osaka University Graduate School of Engineering Science, Osaka, Japan
| | - Ellen Cavalcante Alves
- Department of Mechanical Science and Bioengineering, Osaka University Graduate School of Engineering Science, Osaka, Japan
| | - Shigeo Wada
- Department of Mechanical Science and Bioengineering, Osaka University Graduate School of Engineering Science, Osaka, Japan
| |
Collapse
|
2
|
Degenhardt K, Schmidt S, Aigner CS, Kratzer FJ, Seiter DP, Mueller M, Kolbitsch C, Nagel AM, Wieben O, Schaeffter T, Schulz-Menger J, Schmitter S. Toward accurate and fast velocity quantification with 3D ultrashort TE phase-contrast imaging. Magn Reson Med 2024; 91:1994-2009. [PMID: 38174601 DOI: 10.1002/mrm.29978] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2023] [Revised: 11/28/2023] [Accepted: 11/28/2023] [Indexed: 01/05/2024]
Abstract
PURPOSE Traditional phase-contrast MRI is affected by displacement artifacts caused by non-synchronized spatial- and velocity-encoding time points. The resulting inaccurate velocity maps can affect the accuracy of derived hemodynamic parameters. This study proposes and characterizes a 3D radial phase-contrast UTE (PC-UTE) sequence to reduce displacement artifacts. Furthermore, it investigates the displacement of a standard Cartesian flow sequence by utilizing a displacement-free synchronized-single-point-imaging MR sequence (SYNC-SPI) that requires clinically prohibitively long acquisition times. METHODS 3D flow data was acquired at 3T at three different constant flow rates and varying spatial resolutions in a stenotic aorta phantom using the proposed PC-UTE, a Cartesian flow sequence, and a SYNC-SPI sequence as reference. Expected displacement artifacts were calculated from gradient timing waveforms and compared to displacement values measured in the in vitro flow experiments. RESULTS The PC-UTE sequence reduces displacement and intravoxel dephasing, leading to decreased geometric distortions and signal cancellations in magnitude images, and more spatially accurate velocity quantification compared to the Cartesian flow acquisitions; errors increase with velocity and higher spatial resolution. CONCLUSION PC-UTE MRI can measure velocity vector fields with greater accuracy than Cartesian acquisitions (although pulsatile fields were not studied) and shorter scan times than SYNC-SPI. As such, this approach is superior to traditional Cartesian 3D and 4D flow MRI when spatial misrepresentations cannot be tolerated, for example, when computational fluid dynamics simulations are compared to or combined with in vitro or in vivo measurements, or regional parameters such as wall shear stress are of interest.
Collapse
Affiliation(s)
- Katja Degenhardt
- Physikalisch-Technische Bundesanstalt (PTB), Braunschweig and Berlin, Berlin, Germany
- Department of Radiology, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany
| | - Simon Schmidt
- Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, Minnesota, USA
- Division of Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany
| | - Christoph S Aigner
- Physikalisch-Technische Bundesanstalt (PTB), Braunschweig and Berlin, Berlin, Germany
| | - Fabian J Kratzer
- Division of Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany
| | - Daniel P Seiter
- Department of Medical Physics, University of Wisconsin, Madison, Wisconsin, USA
| | - Max Mueller
- Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| | - Christoph Kolbitsch
- Physikalisch-Technische Bundesanstalt (PTB), Braunschweig and Berlin, Berlin, Germany
| | - Armin M Nagel
- Division of Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany
- Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| | - Oliver Wieben
- Department of Medical Physics, University of Wisconsin, Madison, Wisconsin, USA
- Department of Radiology, University of Wisconsin Madison, Madison, Wisconsin, USA
| | - Tobias Schaeffter
- Physikalisch-Technische Bundesanstalt (PTB), Braunschweig and Berlin, Berlin, Germany
- School of Imaging Science and Biomedical Engineering, King's College London, London, United Kingdom
- Department of Medical Engineering, Technical University of Berlin, Berlin, Germany
| | - Jeanette Schulz-Menger
- Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany
- Working Group on Cardiovascular Magnetic Resonance, Experimental and Clinical Research Center, a joint cooperation between the Charité Medical Faculty and the Max-Delbrueck Center for Molecular Medicine, Berlin, Germany
- DZHK (German Center for Cardiovascular Research), Partner Site Berlin, Berlin, Germany
- Department of Cardiology and Nephrology, HELIOS Hospital Berlin-Buch, Berlin, Germany
| | - Sebastian Schmitter
- Physikalisch-Technische Bundesanstalt (PTB), Braunschweig and Berlin, Berlin, Germany
- Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, Minnesota, USA
- Division of Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany
| |
Collapse
|
3
|
Bissell MM, Raimondi F, Ait Ali L, Allen BD, Barker AJ, Bolger A, Burris N, Carhäll CJ, Collins JD, Ebbers T, Francois CJ, Frydrychowicz A, Garg P, Geiger J, Ha H, Hennemuth A, Hope MD, Hsiao A, Johnson K, Kozerke S, Ma LE, Markl M, Martins D, Messina M, Oechtering TH, van Ooij P, Rigsby C, Rodriguez-Palomares J, Roest AAW, Roldán-Alzate A, Schnell S, Sotelo J, Stuber M, Syed AB, Töger J, van der Geest R, Westenberg J, Zhong L, Zhong Y, Wieben O, Dyverfeldt P. 4D Flow cardiovascular magnetic resonance consensus statement: 2023 update. J Cardiovasc Magn Reson 2023; 25:40. [PMID: 37474977 PMCID: PMC10357639 DOI: 10.1186/s12968-023-00942-z] [Citation(s) in RCA: 42] [Impact Index Per Article: 42.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2023] [Accepted: 05/30/2023] [Indexed: 07/22/2023] Open
Abstract
Hemodynamic assessment is an integral part of the diagnosis and management of cardiovascular disease. Four-dimensional cardiovascular magnetic resonance flow imaging (4D Flow CMR) allows comprehensive and accurate assessment of flow in a single acquisition. This consensus paper is an update from the 2015 '4D Flow CMR Consensus Statement'. We elaborate on 4D Flow CMR sequence options and imaging considerations. The document aims to assist centers starting out with 4D Flow CMR of the heart and great vessels with advice on acquisition parameters, post-processing workflows and integration into clinical practice. Furthermore, we define minimum quality assurance and validation standards for clinical centers. We also address the challenges faced in quality assurance and validation in the research setting. We also include a checklist for recommended publication standards, specifically for 4D Flow CMR. Finally, we discuss the current limitations and the future of 4D Flow CMR. This updated consensus paper will further facilitate widespread adoption of 4D Flow CMR in the clinical workflow across the globe and aid consistently high-quality publication standards.
Collapse
Affiliation(s)
- Malenka M Bissell
- Department of Biomedical Imaging Science, Leeds Institute of Cardiovascular and Metabolic Medicine (LICAMM), LIGHT Laboratories, Clarendon Way, University of Leeds, Leeds, LS2 9NL, UK.
| | | | - Lamia Ait Ali
- Institute of Clinical Physiology CNR, Massa, Italy
- Foundation CNR Tuscany Region G. Monasterio, Massa, Italy
| | - Bradley D Allen
- Department of Radiology, Northwestern University Feinberg School of Medicine, Chicago, IL, USA
| | - Alex J Barker
- Department of Radiology, Children's Hospital Colorado, University of Colorado Anschutz Medical Center, Aurora, USA
| | - Ann Bolger
- Department of Medicine, University of California, San Francisco, CA, USA
- Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden
| | - Nicholas Burris
- Department of Radiology, University of Michigan, Ann Arbor, USA
| | - Carl-Johan Carhäll
- Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden
- Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden
| | | | - Tino Ebbers
- Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden
- Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden
| | | | - Alex Frydrychowicz
- Department of Radiology and Nuclear Medicine, University Hospital Schleswig-Holstein, Campus Lübeck and Universität Zu Lübeck, Lübeck, Germany
| | - Pankaj Garg
- Norwich Medical School, University of East Anglia, Norwich, UK
| | - Julia Geiger
- Department of Diagnostic Imaging, University Children's Hospital, Zurich, Switzerland
- Children's Research Center, University Children's Hospital Zurich, Zurich, Switzerland
| | - Hojin Ha
- Department of Mechanical and Biomedical Engineering, Kangwon National University, Chuncheon, South Korea
| | - Anja Hennemuth
- Institute of Computer-Assisted Cardiovascular Medicine, Charité - Universitätsmedizin, Berlin, Germany
- German Center for Cardiovascular Research (DZHK), Partner Site, Berlin, Germany
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Michael D Hope
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, CA, USA
| | - Albert Hsiao
- Department of Radiology, University of California, San Diego, CA, USA
| | - Kevin Johnson
- Departments of Radiology and Medical Physics, University of Wisconsin, Madison, WI, USA
| | - Sebastian Kozerke
- Institute for Biomedical Engineering, University and ETH Zurich, Zurich, Switzerland
| | - Liliana E Ma
- Department of Radiology, Northwestern University Feinberg School of Medicine, Chicago, IL, USA
| | - Michael Markl
- Department of Radiology, Northwestern University Feinberg School of Medicine, Chicago, IL, USA
| | - Duarte Martins
- Department of Pediatric Cardiology, Hospital de Santa Cruz, Centro Hospitalar Lisboa Ocidental, Lisbon, Portugal
| | - Marci Messina
- Department of Radiology, Northwestern Medicine, Chicago, IL, USA
| | - Thekla H Oechtering
- Department of Radiology and Nuclear Medicine, University Hospital Schleswig-Holstein, Campus Lübeck and Universität Zu Lübeck, Lübeck, Germany
- Departments of Radiology and Medical Physics, University of Wisconsin, Madison, WI, USA
| | - Pim van Ooij
- Department of Radiology & Nuclear Medicine, Amsterdam Cardiovascular Sciences, Amsterdam Movement Sciences, Amsterdam University Medical Centers, Location AMC, Amsterdam, The Netherlands
- Department of Pediatric Cardiology, Division of Pediatrics, Wilhelmina Children's Hospital, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Cynthia Rigsby
- Department of Radiology, Northwestern University Feinberg School of Medicine, Chicago, IL, USA
- Department of Medical Imaging, Ann & Robert H Lurie Children's Hospital of Chicago, Chicago, IL, USA
| | - Jose Rodriguez-Palomares
- Department of Cardiology, Hospital Universitari Vall d´Hebron,Vall d'Hebron Institut de Recerca (VHIR), Universitat Autònoma de Barcelona, Barcelona, Spain
- Centro de Investigación Biomédica en Red-CV, CIBER CV, Madrid, Spain
| | - Arno A W Roest
- Department of Pediatric Cardiology, Willem-Alexander's Children Hospital, Leiden University Medical Center and Center for Congenital Heart Defects Amsterdam-Leiden, Leiden, The Netherlands
| | | | - Susanne Schnell
- Department of Radiology, Northwestern University Feinberg School of Medicine, Chicago, IL, USA
- Department of Medical Physics, Institute of Physics, University of Greifswald, Greifswald, Germany
| | - Julio Sotelo
- School of Biomedical Engineering, Universidad de Valparaíso, Valparaíso, Chile
- Biomedical Imaging Center, Pontificia Universidad Catolica de Chile, Santiago, Chile
- Millennium Institute for Intelligent Healthcare Engineering - iHEALTH, Santiago, Chile
| | - Matthias Stuber
- Département de Radiologie Médicale, Centre Hospitalier Universitaire Vaudois, Lausanne, Switzerland
| | - Ali B Syed
- Department of Radiology, Stanford University, Stanford, CA, USA
| | - Johannes Töger
- Clinical Physiology, Department of Clinical Sciences Lund, Lund University, Skåne University Hospital, Lund, Sweden
| | - Rob van der Geest
- Division of Image Processing, Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands
| | - Jos Westenberg
- CardioVascular Imaging Group (CVIG), Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands
| | - Liang Zhong
- National Heart Centre Singapore, Duke-NUS Medical School, National University of Singapore, Singapore, Singapore
| | - Yumin Zhong
- Department of Radiology, School of Medicine, Shanghai Children's Medical Center Affiliated With Shanghai Jiao Tong University, Shanghai, People's Republic of China
| | - Oliver Wieben
- Departments of Radiology and Medical Physics, University of Wisconsin, Madison, WI, USA
| | - Petter Dyverfeldt
- Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden
- Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden
| |
Collapse
|
4
|
Nath R, Callahan S, Stoddard M, Amini AA. FlowRAU-Net: Accelerated 4D Flow MRI of Aortic Valvular Flows With a Deep 2D Residual Attention Network. IEEE Trans Biomed Eng 2022; 69:3812-3824. [PMID: 35675233 PMCID: PMC10577002 DOI: 10.1109/tbme.2022.3180691] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
In this work, we propose a novel deep learning reconstruction framework for rapid and accurate reconstruction of 4D flow MRI data. Reconstruction is performed on a slice-by-slice basis by reducing artifacts in zero-filled reconstructed complex images obtained from undersampled k-space. A deep residual attention network FlowRAU-Net is proposed, trained separately for each encoding direction with 2D complex image slices extracted from complex 4D images at each temporal frame and slice position. The network was trained and tested on 4D flow MRI data of aortic valvular flow in 18 human subjects. Performance of the reconstructions was measured in terms of image quality, 3-D velocity vector accuracy, and accuracy in hemodynamic parameters. Reconstruction performance was measured for three different k-space undersamplings and compared with one state of the art compressed sensing reconstruction method and three deep learning-based reconstruction methods. The proposed method outperforms state of the art methods in all performance measures for all three different k-space undersamplings. Hemodynamic parameters such as blood flow rate and peak velocity from the proposed technique show good agreement with reference flow parameters. Visualization of the reconstructed image and velocity magnitude also shows excellent agreement with the fully sampled reference dataset. Moreover, the proposed method is computationally fast. Total 4D flow data (including all slices in space and time) for a subject can be reconstructed in 69 seconds on a single GPU. Although the proposed method has been applied to 4D flow MRI of aortic valvular flows, given a sufficient number of training samples, it should be applicable to other arterial flows.
Collapse
|
5
|
Kim D, Eisenmenger L, Turski P, Johnson KM. Simultaneous 3D-TOF angiography and 4D-flow MRI with enhanced flow signal using multiple overlapping thin slab acquisition and magnetization transfer. Magn Reson Med 2021; 87:1401-1417. [PMID: 34708445 DOI: 10.1002/mrm.29060] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2021] [Revised: 10/03/2021] [Accepted: 10/08/2021] [Indexed: 12/29/2022]
Abstract
PURPOSE To investigate the fusion of 3D time-of-flight principles into 4D-flow MRI to enhance vessel contrast and signal without an exogenous contrast agent, enabling simultaneous in-flow based angiograms. METHODS A 4D-flow MRI technique was developed consisting of multiple overlapping slabs with intermittent magnetization transfer preparation. The scan time penalty associated with multiple slab acquisitions was mitigated by using undersampled distributed spiral trajectories and compressed sensing reconstruction. A flow phantom was used to characterize in-flow enhancement, velocity noise improvement, and flow rate measurements against the single-slab 4D-flow MRI. In a patient-volunteer cohort (n = 15), magnitude-based angiograms were radiologically evaluated against 3D time-of-flight, and velocity measurements were compared pixel-wise against single-slab and contrast-enhanced 4D-flow MRI. RESULTS Multiple-slab acquisitions, together with magnetization transfer preparation, substantially improved vessel signal, contrast, and vessel conspicuity in magnitude angiograms. Both clinical 3D time-of-flight and the proposed technique produced equivalent vessel depictions with no statistically significant difference (p < .1). Both techniques also produced clear depictions of brain aneurysms in all patients; however, very small vessels tended to show reduced conspicuity in the proposed technique. Velocity measurements agreed with contrast-enhanced and single-slab scans with high correlations (R2 = 0.941-0.974) and agreements (slopes = 0.994-1.071). Slab boundary and magnetization transfer-related artifacts were not observed in velocity measurements, and velocity noise was reduced with in-flow enhancement over single-slab scans (phantom). CONCLUSION The vessel signal and contrast can be improved in 4D-flow MRI without exogenous contrast agents by utilizing in-flow enhancement, efficient sampling, and compressed sensing. The in-flow enhancement also enables simultaneous 3D time-of-flight angiograms useful for flow quantification and diagnosis.
Collapse
Affiliation(s)
- Dahan Kim
- Department of Physics, University of Wisconsin, Madison, Wisconsin, USA.,Department of Medical Physics, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin, USA
| | - Laura Eisenmenger
- Department of Radiology, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin, USA
| | - Patrick Turski
- Department of Radiology, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin, USA
| | - Kevin M Johnson
- Department of Medical Physics, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin, USA.,Department of Radiology, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin, USA
| |
Collapse
|
6
|
Komoriyama H, Kamiya K, Nagai T, Oyama-Manabe N, Tsuneta S, Kobayashi Y, Kato Y, Sarashina M, Omote K, Konishi T, Sato T, Tsujinaga S, Iwano H, Shingu Y, Wakasa S, Anzai T. Blood flow dynamics with four-dimensional flow cardiovascular magnetic resonance in patients with aortic stenosis before and after transcatheter aortic valve replacement. J Cardiovasc Magn Reson 2021; 23:81. [PMID: 34176516 PMCID: PMC8237445 DOI: 10.1186/s12968-021-00771-y] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2020] [Accepted: 05/04/2021] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Pre- and post-procedural hemodynamic changes which could affect adverse outcomes in aortic stenosis (AS) patients who undergo transcatheter aortic valve replacement (TAVR) have not been well investigated. Four-dimensional (4D) flow cardiovascular magnetic resonance (CMR) enables accurate analysis of blood flow dynamics such as flow velocity, flow pattern, wall shear stress (WSS), and energy loss (EL). We sought to examine the changes in blood flow dynamics of patients with severe AS who underwent TAVR. METHODS We examined 32 consecutive severe AS patients who underwent TAVR between May 2018 and June 2019 (17 men, 82 ± 5 years, median left ventricular ejection fraction 61%, 6 self-expanding valve), after excluding those without CMR because of a contraindication or inadequate imaging from the analyses. We analyzed blood flow patterns, WSS and EL in the ascending aorta (AAo), and those changes before and after TAVR using 4D flow CMR. RESULTS After TAVR, semi-quantified helical flow in the AAo was significantly decreased (1.4 ± 0.6 vs. 1.9 ± 0.8, P = 0.002), whereas vortical flow and eccentricity showed no significant changes. WSS along the ascending aortic circumference was significantly decreased in the left (P = 0.038) and left anterior (P = 0.033) wall at the basal level, right posterior (P = 0.011) and left (P = 0.010) wall at the middle level, and right (P = 0.012), left posterior (P = 0.019) and left anterior (P = 0.028) wall at the upper level. EL in the AAo was significantly decreased (15.6 [10.8-25.1 vs. 25.8 [18.6-36.2]] mW, P = 0.012). Furthermore, a significant negative correlation was observed between EL and effective orifice area index after TAVR (r = - 0.38, P = 0.034). CONCLUSIONS In severe AS patients undergoing TAVR, 4D flow CMR demonstrates that TAVR improves blood flow dynamics, especially when a larger effective orifice area index is obtained.
Collapse
Affiliation(s)
- Hirokazu Komoriyama
- Department of Cardiovascular Medicine, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Kita 15, Nishi 7, Kita-ku, Sapporo, Hokkaido, 060-8638, Japan
| | - Kiwamu Kamiya
- Department of Cardiovascular Medicine, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Kita 15, Nishi 7, Kita-ku, Sapporo, Hokkaido, 060-8638, Japan
| | - Toshiyuki Nagai
- Department of Cardiovascular Medicine, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Kita 15, Nishi 7, Kita-ku, Sapporo, Hokkaido, 060-8638, Japan.
| | - Noriko Oyama-Manabe
- Department of Diagnostic and Interventional Radiology, Hokkaido University Hospital, Kita 14, Nishi 5, Kita-ku, Sapporo, Hokkaido, 060-8648, Japan
| | - Satonori Tsuneta
- Department of Diagnostic and Interventional Radiology, Hokkaido University Hospital, Kita 14, Nishi 5, Kita-ku, Sapporo, Hokkaido, 060-8648, Japan
| | - Yuta Kobayashi
- Department of Cardiovascular Medicine, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Kita 15, Nishi 7, Kita-ku, Sapporo, Hokkaido, 060-8638, Japan
| | - Yoshiya Kato
- Department of Cardiovascular Medicine, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Kita 15, Nishi 7, Kita-ku, Sapporo, Hokkaido, 060-8638, Japan
| | - Miwa Sarashina
- Department of Cardiovascular Medicine, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Kita 15, Nishi 7, Kita-ku, Sapporo, Hokkaido, 060-8638, Japan
| | - Kazunori Omote
- Department of Cardiovascular Medicine, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Kita 15, Nishi 7, Kita-ku, Sapporo, Hokkaido, 060-8638, Japan
| | - Takao Konishi
- Department of Cardiovascular Medicine, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Kita 15, Nishi 7, Kita-ku, Sapporo, Hokkaido, 060-8638, Japan
| | - Takuma Sato
- Department of Cardiovascular Medicine, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Kita 15, Nishi 7, Kita-ku, Sapporo, Hokkaido, 060-8638, Japan
| | - Shingo Tsujinaga
- Department of Cardiovascular Medicine, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Kita 15, Nishi 7, Kita-ku, Sapporo, Hokkaido, 060-8638, Japan
| | - Hiroyuki Iwano
- Department of Cardiovascular Medicine, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Kita 15, Nishi 7, Kita-ku, Sapporo, Hokkaido, 060-8638, Japan
| | - Yasushige Shingu
- Department of Cardiovascular and Thoracic Surgery, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Kita 15, Nishi 7, Kita-ku, Sapporo, Hokkaido, 060-8638, Japan
| | - Satoru Wakasa
- Department of Cardiovascular and Thoracic Surgery, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Kita 15, Nishi 7, Kita-ku, Sapporo, Hokkaido, 060-8638, Japan
| | - Toshihisa Anzai
- Department of Cardiovascular Medicine, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Kita 15, Nishi 7, Kita-ku, Sapporo, Hokkaido, 060-8638, Japan
| |
Collapse
|
7
|
Is CMR the gold standard for evaluating transvalvular flow? Int J Cardiol 2020; 317:221-222. [DOI: 10.1016/j.ijcard.2020.06.060] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/13/2020] [Accepted: 06/26/2020] [Indexed: 11/22/2022]
|
8
|
Callahan S, Singam NS, Kendrick M, Negahdar MJ, Wang H, Stoddard MF, Amini AA. Dual-V enc acquisition for 4D flow MRI in aortic stenosis with spiral readouts. J Magn Reson Imaging 2019; 52:117-128. [PMID: 31850597 DOI: 10.1002/jmri.27004] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2019] [Accepted: 10/28/2019] [Indexed: 12/30/2022] Open
Abstract
BACKGROUND Single Venc 4D flow MRI with Cartesian readout is hampered by poor velocity resolution and noise when imaging during diastole. Dual Venc acquisitions typically require the acquisition of two distinct datasets, which leads to longer scan times. PURPOSE/HYPOTHESIS To design and develop a 4D Spiral Dual Venc sequence. The sequence allows for separate systolic and diastolic Venc s as part of a single acquisition with a prescribed switch time. The implemented sequence was hypothesized to be comparable to Cartesian 4D flow, but with increased velocity resolution in the diastolic phase and with better scan efficiency and reduced noise. STUDY TYPE Prospective. POPULATION The studied populations were two phantoms-a straight pipe with a stenotic narrowing and a phantom of the aortic arch which included a calcific polymeric valve-under both steady and pulsatile flows, six healthy volunteers, and eight patients with severe aortic stenosis (AS). FIELD STRENGTH/SEQUENCE 1.5T, Dual Venc 4D flow with spiral readouts. ASSESSMENT Data from the proposed sequence were compared with data from 4D Cartesian Dual Venc and Single Venc acquisitions. Noise was assessed from the acquired velocity data with the pump turned off and by varying Venc . Steady acquisitions were compared to the proximal slice of the lowest Single Venc acquisition. STATISTICAL TESTS Steady flows were compared using relative-root-mean-squared-error (RRMSE). For in vivo flows and pulsatile in vitro flows, net flow for corresponding timepoints were compared with the Pearson correlation test (P < 0.01). RESULTS For steady flows, RRMSEs for Single Venc s ranged from 17.6% to 19.4%, and 9.6% to 16.5% for Dual Venc s. The net flow correlation coefficient for the aortic arch phantom was 0.975, and 0.995 for the stenotic phantom. Normal volunteer and patient comparisons yielded a correlation of 0.970 and 0.952, respectively. in vitro and in vivo pulsatile flow waveforms closely matched. DATA CONCLUSION The Dual Venc offers improved noise properties and velocity resolution, while the spiral trajectory offers a scan efficient acquisition with short echo time yielding reduced flow artifacts. LEVEL OF EVIDENCE 2 Technical Efficacy Stage: 1 J. Magn. Reson. Imaging 2020;52:117-128.
Collapse
Affiliation(s)
- Sean Callahan
- Medical Imaging Lab, Department of Electrical and Computer Engineering, University of Louisville, Louisville, Kentucky, USA.,Robley Rex Veterans Affairs Medical Center, Louisville, Kentucky, USA
| | - Narayana S Singam
- Division of Cardiovascular Medicine, University of Louisville, School of Medicine, Louisville, Kentucky, USA
| | - Michael Kendrick
- Robley Rex Veterans Affairs Medical Center, Louisville, Kentucky, USA
| | - M J Negahdar
- Department of Radiology, University of Louisville, Louisville, Kentucky, USA
| | - Hui Wang
- Philips Healthcare, Cleveland, Ohio, USA
| | - Marcus F Stoddard
- Robley Rex Veterans Affairs Medical Center, Louisville, Kentucky, USA.,Division of Cardiovascular Medicine, University of Louisville, School of Medicine, Louisville, Kentucky, USA
| | - Amir A Amini
- Medical Imaging Lab, Department of Electrical and Computer Engineering, University of Louisville, Louisville, Kentucky, USA.,Robley Rex Veterans Affairs Medical Center, Louisville, Kentucky, USA
| |
Collapse
|
9
|
Malone A, Chari D, Cournane S, Naydenova I, Fagan A, Browne J. Investigation of the assessment of low degree (<50%) renal artery stenosis based on velocity flow profile analysis using Doppler ultrasound: An in-vitro study. Phys Med 2019; 65:209-218. [PMID: 31518907 DOI: 10.1016/j.ejmp.2019.08.016] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/01/2019] [Revised: 08/21/2019] [Accepted: 08/23/2019] [Indexed: 11/24/2022] Open
Abstract
PURPOSE Renal arterial stenosis can lead to disrupted renal function due to reduced blood flow to the kidneys and is largely thought to be caused by atherosclerosis. Current diagnostic strategies for renal arterial stenosis rely on detecting large degree stenoses (>50%). This study aimed to test the viability of using Doppler ultrasound to assess velocity profiles to detect the presence of low degree (<50%) stenoses. METHODS A series of anatomically realistic renal artery flow phantoms were constructed exhibiting a range of low degree stenoses (symmetric and asymmetric). The behaviour of fluid flow in the phantoms was examined using Doppler ultrasound and analysed to calculate the clinical biomarker, wall shear stress. RESULTS A number of fluid behaviours were observed in relation to stenosis degree: asymmetric stenoses tended to result in a skewing of peak velocities away from the centre of the vessel towards the outer wall, the magnitude of increase in velocity was observed to correlate with stenosis degree, and the wall shear stress curves observed large peaks in the presence of even the lowest degree stenosis (20%). CONCLUSIONS Doppler ultrasound could potentially be utilised to diagnose low degree stenoses in a clinical setting. Doppler ultrasound in conjunction with wall shear stress analysis in particular has significant potential in the diagnosis of renal artery stenosis.
Collapse
Affiliation(s)
- Andrew Malone
- School of Physics and Clinical & Optometric Sciences, College of Science and Health, Technological University Dublin, Dublin, Ireland.
| | - Deepa Chari
- STEM Transformation Institute, Florida International University, Miami, USA
| | | | - Izabela Naydenova
- School of Physics and Clinical & Optometric Sciences, College of Science and Health, Technological University Dublin, Dublin, Ireland
| | - Andrew Fagan
- Department of Radiology, Mayo Clinic, Rochester, MN, USA
| | - Jacinta Browne
- Department of Radiology, Mayo Clinic, Rochester, MN, USA
| |
Collapse
|
10
|
Callahan S, Henn A, Kendrick M, Wang H, Negahdar MJ, Kheradvar A, Stoddard M, Amini A. 4D Dual-V enc Spiral Flow. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2018; 2018:1372-1375. [PMID: 30440647 DOI: 10.1109/embc.2018.8512573] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Dual-Venc flow acquisition sequences perform flow imaging with differing Vencs. The technique can be used to improve velocity to noise ratio and image quality for diastolic flow velocities as part of a single scan. In this paper, Dual-Venc was used in conjunction with spiral read-out trajectories, offering a faster coverage of k-space. The results illustrate that 4D Dual Venc Spiral Flow behaves similarly to 4D Dual-Venc Cartesian Flow but with the benefit of faster acquisition time and lower echo time (TE).
Collapse
|
11
|
Bruschewski M, Kolkmannn H, John K, Grundmann S. Phase-contrast single-point imaging with synchronized encoding: a more reliable technique for in vitro flow quantification. Magn Reson Med 2018; 81:2937-2946. [DOI: 10.1002/mrm.27604] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2018] [Revised: 10/17/2018] [Accepted: 10/19/2018] [Indexed: 11/09/2022]
Affiliation(s)
| | - Hanna Kolkmannn
- Institute of Fluid Mechanics; University of Rostock; Rostock Germany
| | - Kristine John
- Institute of Fluid Mechanics; University of Rostock; Rostock Germany
| | - Sven Grundmann
- Institute of Fluid Mechanics; University of Rostock; Rostock Germany
| |
Collapse
|
12
|
Krämer M, Motaal AG, Herrmann KH, Löffler B, Reichenbach JR, Strijkers GJ, Hoerr V. Cardiac 4D phase-contrast CMR at 9.4 T using self-gated ultra-short echo time (UTE) imaging. J Cardiovasc Magn Reson 2017; 19:39. [PMID: 28359292 PMCID: PMC5374606 DOI: 10.1186/s12968-017-0351-9] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2016] [Accepted: 03/02/2017] [Indexed: 12/26/2022] Open
Abstract
BACKGROUND Time resolved 4D phase contrast (PC) cardiovascular magnetic resonance (CMR) in mice is challenging due to long scan times, small animal ECG-gating and the rapid blood flow and cardiac motion of small rodents. To overcome several of these technical challenges we implemented a retrospectively self-gated 4D PC radial ultra-short echo-time (UTE) acquisition scheme and assessed its performance in healthy mice by comparing the results with those obtained with an ECG-triggered 4D PC fast low angle shot (FLASH) sequence. METHODS Cardiac 4D PC CMR images were acquired at 9.4 T in healthy mice using the proposed self-gated radial center-out UTE acquisition scheme (TE/TR of 0.5 ms/3.1 ms) and a standard Cartesian 4D PC imaging sequence (TE/TR of 2.1 ms/5.0 ms) with a four-point Hadamard flow encoding scheme. To validate the proposed UTE flow imaging technique, experiments on a flow phantom with variable pump rates were performed. RESULTS The anatomical images and flow velocity maps of the proposed 4D PC UTE technique showed reduced artifacts and an improved SNR (left ventricular cavity (LV): 8.9 ± 2.5, myocardium (MC): 15.7 ± 1.9) compared to those obtained using a typical Cartesian FLASH sequence (LV: 5.6 ± 1.2, MC: 10.1 ± 1.4) that was used as a reference. With both sequences comparable flow velocities were obtained in the flow phantom as well as in the ascending aorta (UTE: 132.8 ± 18.3 cm/s, FLASH: 134.7 ± 13.4 cm/s) and pulmonary artery (UTE: 78.5 ± 15.4 cm/s, FLASH: 86.6 ± 6.2 cm/s) of the animals. Self-gated navigator signals derived from information of the oversampled k-space center were successfully extracted for all animals with a higher gating efficiency of time spent on acquiring gated data versus total measurement time (UTE: 61.8 ± 11.5%, FLASH: 48.5 ± 4.9%). CONCLUSIONS The proposed self-gated 4D PC UTE sequence enables robust and accurate flow velocity mapping of the mouse heart in vivo at high magnetic fields. At the same time SNR, gating efficiency, flow artifacts and image quality all improved compared to the images obtained using the well-established, ECG-triggered, 4D PC FLASH sequence.
Collapse
Affiliation(s)
- M. Krämer
- Medical Physics Group, Institute of Diagnostic and Interventional Radiology, Jena University Hospital - Friedrich Schiller University Jena, Philosophenweg 3, D-07743 Jena, Germany
| | - A. G. Motaal
- Biomedical NMR, Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, Netherlands
| | - K-H. Herrmann
- Medical Physics Group, Institute of Diagnostic and Interventional Radiology, Jena University Hospital - Friedrich Schiller University Jena, Philosophenweg 3, D-07743 Jena, Germany
| | - B. Löffler
- Institute of Medical Microbiology, Jena University Hospital, Friedrich Schiller University Jena, Jena, Germany
| | - J. R. Reichenbach
- Medical Physics Group, Institute of Diagnostic and Interventional Radiology, Jena University Hospital - Friedrich Schiller University Jena, Philosophenweg 3, D-07743 Jena, Germany
- Michael Stifel Center for Data-driven and Simulation Science Jena, Friedrich Schiller University Jena, Jena, Germany
- Abbe School of Photonics, Friedrich Schiller University Jena, Jena, Germany
- Center of Medical Optics and Photonics, Friedrich Schiller University Jena, Jena, Germany
| | - G. J. Strijkers
- Biomedical NMR, Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, Netherlands
- Biomedical Engineering and Physics, Academic Medical Center, Amsterdam, Netherlands
| | - V. Hoerr
- Institute of Medical Microbiology, Jena University Hospital, Friedrich Schiller University Jena, Jena, Germany
| |
Collapse
|
13
|
Wu C, Schnell S, Vakil P, Honarmand AR, Ansari SA, Carr J, Markl M, Prabhakaran S. In Vivo Assessment of the Impact of Regional Intracranial Atherosclerotic Lesions on Brain Arterial 3D Hemodynamics. AJNR Am J Neuroradiol 2017; 38:515-522. [PMID: 28057635 DOI: 10.3174/ajnr.a5051] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2016] [Accepted: 10/26/2016] [Indexed: 11/07/2022]
Abstract
BACKGROUND AND PURPOSE Intracranial atherosclerosis induces hemodynamic disturbance, which is not well-characterized, particularly in cerebral flow redistribution. We aimed to characterize the impact of regional stenotic lesions on intracranial hemodynamics by using 4D flow MR imaging. MATERIALS AND METHODS 4D flow MR imaging was performed in 22 symptomatic patients (mean age, 68.4 ± 14.2 years) with intracranial stenosis (ICA, n = 7; MCA, n = 9; basilar artery, n = 6) and 10 age-appropriate healthy volunteers (mean age, 60.7 ± 8.1 years). 3D blood flow patterns were visualized by using time-integrated pathlines. Blood flow and peak velocity asymmetry indices were compared between patients and healthy volunteers in 4 prespecified arteries: ICAs, MCAs, and anterior/posterior cerebral arteries. RESULTS 3D blood flow pathlines demonstrated flow redistribution across cerebral arteries in patients with unilateral intracranial stenosis. For patients with ICA stenosis compared with healthy volunteers, significantly lower flow and peak velocities were identified in the ipsilateral ICA (P = .001 and P = .001) and MCA (P < .001 and P = .001), but higher flow, in the ipsilateral PCA (P < .001). For patients with MCA stenosis, significantly lower flow and peak velocities were observed in the ipsilateral ICA (P = .009 and P = .045) and MCA (P < .001 and P = .005), but significantly higher flow was found in the ipsilateral posterior cerebral artery (P = .014) and anterior cerebral artery (P = .006). The asymmetry indices were not significantly different between patients with basilar artery stenosis and the healthy volunteers. CONCLUSIONS Regional intracranial atherosclerotic lesions not only alter distal arterial flow but also significantly affect ipsilateral collateral arterial hemodynamics.
Collapse
Affiliation(s)
- C Wu
- From the Department of Biomedical Engineering (C.W., M.M.), McCormick School of Engineering, Northwestern University, Chicago, Illinois .,Departments of Radiology (C.W., S.S., P.V., A.R.H., S.A.A., J.C., M.M.).,Philips Healthcare (C.W.), Gainesville, Florida
| | - S Schnell
- Departments of Radiology (C.W., S.S., P.V., A.R.H., S.A.A., J.C., M.M.)
| | - P Vakil
- Departments of Radiology (C.W., S.S., P.V., A.R.H., S.A.A., J.C., M.M.)
| | - A R Honarmand
- Departments of Radiology (C.W., S.S., P.V., A.R.H., S.A.A., J.C., M.M.)
| | - S A Ansari
- Departments of Radiology (C.W., S.S., P.V., A.R.H., S.A.A., J.C., M.M.).,Neurological Surgery (S.A.A.)
| | - J Carr
- Departments of Radiology (C.W., S.S., P.V., A.R.H., S.A.A., J.C., M.M.)
| | - M Markl
- From the Department of Biomedical Engineering (C.W., M.M.), McCormick School of Engineering, Northwestern University, Chicago, Illinois.,Departments of Radiology (C.W., S.S., P.V., A.R.H., S.A.A., J.C., M.M.)
| | - S Prabhakaran
- Neurology (S.P.), Feinberg School of Medicine, Northwestern University, Chicago, Illinois
| |
Collapse
|
14
|
Golshani S, Nasiraei-Moghaddam A. Efficient radial tagging CMR exam: A coherent k-space reading and image reconstruction approach. Magn Reson Med 2016; 77:1459-1472. [PMID: 27052351 DOI: 10.1002/mrm.26219] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2015] [Revised: 02/15/2016] [Accepted: 02/24/2016] [Indexed: 01/28/2023]
Abstract
PURPOSE Cardiac MR tagging techniques, which facilitate the strain evaluation, have not yet been widely adopted in clinics due to inefficiencies in acquisition and postprocessing. This problem may be alleviated by exploiting the coherency in the three steps of tagging: preparation, acquisition, and reconstruction. Herein, we propose a fully polar-based tagging approach that may lead to real-time strain mapping. METHODS Radial readout trajectories were used to acquire radial tagging images and a Hankel-based algorithm, referred to as Polar Fourier Transform (PFT), has been adapted for reconstruction of the acquired raw data. In both phantom and human subjects, the overall performance of the method was investigated against radial undersampling and compared with the conventional reconstruction methods. RESULTS Radially tagged images were reconstructed by the proposed PFT method from as few as 24 spokes with normalized root-mean-square-error of less than 3%. The reconstructed images showed a central focusing behavior, where the undersampling effects were pushed to the peripheral areas out of the central region of interest. Comparing the results with the re-gridding reconstruction technique, superior image quality and high robustness of the method were further established. In addition, a relative increase of 68 ± 2.5% in tagline sharpness was achieved for the PFT images and also higher tagging contrast (72 ± 5.6%), resulted from the well-tolerated undersampling artifacts, was observed in all reconstructions. CONCLUSION The proposed approach led to the acceleration of the acquisition process, which was evaluated for up to eight-fold retrospectively from the fully sampled data. This is promising toward real-time imaging, and in contrast to iterative techniques, the method is consistent with online reconstruction. Magn Reson Med 77:1459-1472, 2017. © 2016 International Society for Magnetic Resonance in Medicine.
Collapse
|
15
|
Trotier AJ, Castets CR, Lefrançois W, Ribot EJ, Franconi JM, Thiaudière E, Miraux S. USPIO-enhanced 3D-cine self-gated cardiac MRI based on a stack-of-stars golden angle short echo time sequence: Application on mice with acute myocardial infarction. J Magn Reson Imaging 2016; 44:355-65. [PMID: 26778077 DOI: 10.1002/jmri.25150] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2015] [Accepted: 12/23/2015] [Indexed: 12/17/2022] Open
Abstract
PURPOSE To develop and assess a 3D-cine self-gated method for cardiac imaging of murine models. MATERIALS AND METHODS A 3D stack-of-stars (SOS) short echo time (STE) sequence with a navigator echo was performed at 7T on healthy mice (n = 4) and mice with acute myocardial infarction (MI) (n = 4) injected with ultrasmall superparamagnetic iron oxide (USPIO) nanoparticles. In all, 402 spokes were acquired per stack with the incremental or the golden angle method using an angle increment of (360/402)° or 222.48°, respectively. A cylindrical k-space was filled and repeated with a maximum number of repetitions (NR) of 10. 3D cine cardiac images at 156 μm resolution were reconstructed retrospectively and compared for the two methods in terms of contrast-to-noise ratio (CNR). The golden angle images were also reconstructed with NR = 10, 6, and 3, to assess cardiac functional parameters (ejection fraction, EF) on both animal models. RESULTS The combination of 3D SOS-STE and USPIO injection allowed us to optimize the identification of cardiac peaks on navigator signal and generate high CNR between blood and myocardium (15.3 ± 1.0). The golden angle method resulted in a more homogeneous distribution of the spokes inside a stack (P < 0.05), enabling reducing the acquisition time to 15 minutes. EF was significantly different between healthy and MI mice (P < 0.05). CONCLUSION The method proposed here showed that 3D-cine images could be obtained without electrocardiogram or respiratory gating in mice. It allows precise measurement of cardiac functional parameters even on MI mice. J. Magn. Reson. Imaging 2016;44:355-365.
Collapse
Affiliation(s)
- Aurélien J Trotier
- Centre de Résonance Magnétique des Systèmes Biologiques, UMR 5536 Université de Bordeaux, Bordeaux, France
| | - Charles R Castets
- Centre de Résonance Magnétique des Systèmes Biologiques, UMR 5536 Université de Bordeaux, Bordeaux, France
| | - William Lefrançois
- Centre de Résonance Magnétique des Systèmes Biologiques, UMR 5536 Université de Bordeaux, Bordeaux, France
| | - Emeline J Ribot
- Centre de Résonance Magnétique des Systèmes Biologiques, UMR 5536 Université de Bordeaux, Bordeaux, France
| | - Jean-Michel Franconi
- Centre de Résonance Magnétique des Systèmes Biologiques, UMR 5536 Université de Bordeaux, Bordeaux, France
| | - Eric Thiaudière
- Centre de Résonance Magnétique des Systèmes Biologiques, UMR 5536 Université de Bordeaux, Bordeaux, France
| | - Sylvain Miraux
- Centre de Résonance Magnétique des Systèmes Biologiques, UMR 5536 Université de Bordeaux, Bordeaux, France
| |
Collapse
|
16
|
van den Berg P, Daoudi K, Steenbergen W. Review of photoacoustic flow imaging: its current state and its promises. PHOTOACOUSTICS 2015; 3:89-99. [PMID: 26640771 PMCID: PMC4595496 DOI: 10.1016/j.pacs.2015.08.001] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/18/2015] [Revised: 07/24/2015] [Accepted: 08/02/2015] [Indexed: 05/04/2023]
Abstract
Flow imaging is an important method for quantification in many medical imaging modalities, with applications ranging from estimating wall shear rate to detecting angiogenesis. Modalities like ultrasound and optical coherence tomography both offer flow imaging capabilities, but suffer from low contrast to red blood cells and are sensitive to clutter artefacts. Photoacoustic imaging (PAI) is a relatively new field, with a recent interest in flow imaging. The recent enthusiasm for PA flow imaging is due to its intrinsic contrast to haemoglobin, which offers a new spin on existing methods of flow imaging, and some unique approaches in addition. This review article will delve into the research on photoacoustic flow imaging, explain the principles behind the many techniques and comment on their individual advantages and disadvantages.
Collapse
|
17
|
Negahdar MJ, Kadbi M, Kendrick M, Stoddard MF, Amini AA. 4D spiral imaging of flows in stenotic phantoms and subjects with aortic stenosis. Magn Reson Med 2015; 75:1018-29. [PMID: 25914199 DOI: 10.1002/mrm.25636] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2014] [Revised: 12/17/2014] [Accepted: 01/05/2015] [Indexed: 11/09/2022]
Abstract
PURPOSE The utility of four-dimensional (4D) spiral flow in imaging of stenotic flows in both phantoms and human subjects with aortic stenosis is investigated. METHODS The method performs 4D flow acquisitions through a stack of interleaved spiral k-space readouts. Relative to conventional 4D flow, which performs Cartesian readout, the method has reduced echo time. Thus, reduced flow artifacts are observed when imaging high-speed stenotic flows. Four-dimensional spiral flow also provides significant savings in scan times relative to conventional 4D flow. RESULTS In vitro experiments were performed under both steady and pulsatile flows in a phantom model of severe stenosis (one inch diameter at the inlet, with 87% area reduction at the throat of the stenosis) while imaging a 6-cm axial extent of the phantom, which included the Gaussian-shaped stenotic narrowing. In all cases, gradient strength and slew rate for standard clinical acquisitions, and identical field of view and resolution were used. For low steady flow rates, quantitative and qualitative results showed a similar level of accuracy between 4D spiral flow (echo time [TE] = 2 ms, scan time = 40 s) and conventional 4D flow (TE = 3.6 ms, scan time = 1:01 min). However, in the case of high steady flow rates, 4D spiral flow (TE = 1.57 ms, scan time = 38 s) showed better visualization and accuracy as compared to conventional 4D flow (TE = 3.2 ms, scan time = 51 s). At low pulsatile flow rates, a good agreement was observed between 4D spiral flow (TE = 2 ms, scan time = 10:26 min) and conventional 4D flow (TE = 3.6 ms, scan time = 14:20 min). However, in the case of high flow-rate pulsatile flows, 4D spiral flow (TE = 1.57 ms, scan time = 10:26 min) demonstrated better visualization as compared to conventional 4D flow (TE = 3.2 ms, scan time = 14:20 min). The feasibility of 4D spiral flow was also investigated in five normal volunteers and four subjects with mild-to-moderate aortic stenosis. The approach achieved TE = 1.68 ms and scan time = 3:44 min. The conventional sequence achieved TE = 2.9 ms and scan time = 5:23 min. In subjects with aortic stenosis, we also compared both MRI methods with Doppler ultrasound (US) in the measurement of peak velocity, time to peak systolic velocity, and eject time. Bland-Altman analysis revealed that, when comparing peak velocities, the discrepancy between Doppler US and 4D spiral flow was significantly less than the discrepancy between Doppler and 4D Cartesian flow (2.75 cm/s vs. 10.25 cm/s), whereas the two MR methods were comparable (-5.75 s vs. -6 s) for time to peak. However, for the estimation of eject time, relative to Doppler US, the discrepancy for 4D conventional flow was smaller than that of 4D spiral flow (-16.25 s vs. -20 s). CONCLUSION Relative to conventional 4D flow, 4D spiral flow achieves substantial reductions in both the TE and scan times; therefore, utility for it should be sought in a variety of in vivo and complex flow imaging applications.
Collapse
Affiliation(s)
- M J Negahdar
- Medical Imaging Lab, Department of Electrical and Computer Engineering, University of Louisville, Louisville, Kentucky, USA.,Robley Rex Veterans Affairs Medical Center, Louisville, Kentucky, USA
| | - Mo Kadbi
- Philips Medical Systems, Philips Healthcare, Cleveland, Ohio, USA
| | - Michael Kendrick
- Robley Rex Veterans Affairs Medical Center, Louisville, Kentucky, USA
| | - Marcus F Stoddard
- Robley Rex Veterans Affairs Medical Center, Louisville, Kentucky, USA.,Division of Cardiovascular Medicine, University of Louisville, School of Medicine, Louisville, Kentucky, USA
| | - Amir A Amini
- Medical Imaging Lab, Department of Electrical and Computer Engineering, University of Louisville, Louisville, Kentucky, USA.,Robley Rex Veterans Affairs Medical Center, Louisville, Kentucky, USA
| |
Collapse
|
18
|
Petersson S, Dyverfeldt P, Sigfridsson A, Lantz J, Carlhäll CJ, Ebbers T. Quantification of turbulence and velocity in stenotic flow using spiral three-dimensional phase-contrast MRI. Magn Reson Med 2015; 75:1249-55. [PMID: 25846511 PMCID: PMC6618270 DOI: 10.1002/mrm.25698] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2014] [Revised: 02/03/2015] [Accepted: 02/24/2015] [Indexed: 11/16/2022]
Abstract
Purpose Evaluate spiral three‐dimensional (3D) phase contrast MRI for the assessment of turbulence and velocity in stenotic flow. Methods A‐stack‐of‐spirals 3D phase contrast MRI sequence was evaluated in vitro against a conventional Cartesian sequence. Measurements were made in a flow phantom with a 75% stenosis. Both spiral and Cartesian imaging were performed using different scan orientations and flow rates. Volume flow rate, maximum velocity and turbulent kinetic energy (TKE) were computed for both methods. Moreover, the estimated TKE was compared with computational fluid dynamics (CFD) data. Results There was good agreement between the turbulent kinetic energy from the spiral, Cartesian and CFD data. Flow rate and maximum velocity from the spiral data agreed well with Cartesian data. As expected, the short echo time of the spiral sequence resulted in less prominent displacement artifacts compared with the Cartesian sequence. However, both spiral and Cartesian flow rate estimates were sensitive to displacement when the flow was oblique to the encoding directions. Conclusion Spiral 3D phase contrast MRI appears favorable for the assessment of stenotic flow. The spiral sequence was more than three times faster and less sensitive to displacement artifacts when compared with a conventional Cartesian sequence. Magn Reson Med 75:1249–1255, 2016. © 2015 Wiley Periodicals, Inc.
Collapse
Affiliation(s)
- Sven Petersson
- Division of Cardiovascular Medicine, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden.,Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden
| | - Petter Dyverfeldt
- Division of Cardiovascular Medicine, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden.,Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden.,Division of Media and Information Technology, Department of Science and Technology/Swedish e-Science Research Centre (SeRC), Linköping University, Linköping, Sweden
| | - Andreas Sigfridsson
- Department of Clinical Physiology, Karolinska Institutet and Karolinska University Hospital, Stockholm, Sweden
| | - Jonas Lantz
- Division of Media and Information Technology, Department of Science and Technology/Swedish e-Science Research Centre (SeRC), Linköping University, Linköping, Sweden
| | - Carl-Johan Carlhäll
- Division of Cardiovascular Medicine, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden.,Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden.,Department of Clinical Physiology, Institution of Medicine and Health Sciences, Linköping University, Linköping, Sweden
| | - Tino Ebbers
- Division of Cardiovascular Medicine, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden.,Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden.,Division of Media and Information Technology, Department of Science and Technology/Swedish e-Science Research Centre (SeRC), Linköping University, Linköping, Sweden
| |
Collapse
|
19
|
Velocity mapping of the aortic flow at 9.4 T in healthy mice and mice with induced heart failure using time-resolved three-dimensional phase-contrast MRI (4D PC MRI). MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE 2014; 28:315-27. [PMID: 25381179 PMCID: PMC4515240 DOI: 10.1007/s10334-014-0466-z] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/26/2014] [Revised: 09/23/2014] [Accepted: 10/14/2014] [Indexed: 11/28/2022]
Abstract
Objectives In this study, we established and validated a time-resolved three-dimensional phase-contrast magnetic resonance imaging method (4D PC MRI) on a 9.4 T small-animal MRI system. Herein we present the feasibility of 4D PC MRI in terms of qualitative and quantitative flow pattern analysis in mice with transverse aortic constriction (TAC). Materials and methods 4D PC FLASH images of a flow phantom and mouse heart were acquired at 9.4 T using a four-point phase-encoding scheme. The method was compared with slice-selective PC FLASH and ultrasound using Bland–Altman analysis. Advanced 3D streamlines were visualized utilizing Voreen volume-rendering software. Results In vitro, 4D PC MRI flow profiles showed the transition between laminar and turbulent flow with increasing velocities. In vivo, 4D PC MRI data of the ascending aorta and the pulmonary artery were confirmed by ultrasound, resulting in linear regressions of R2 > 0.93. Magnitude- and direction-encoded streamlines differed substantially pre- and post-TAC surgery. Conclusions 4D PC MRI is a feasible tool for in vivo velocity measurements on high-field small-animal scanners. Similar to clinical measurement, this method provides a complete spatially and temporally resolved dataset of the murine cardiovascular blood flow and allows for three-dimensional flow pattern analysis. Electronic supplementary material The online version of this article (doi:10.1007/s10334-014-0466-z) contains supplementary material, which is available to authorized users.
Collapse
|