1
|
Wang C, Han X, Ma X, Jiang W, Wang J, Li S, Guo H, Tian W, Chen H. Spinal cord perfusion is associated with microstructural damage in cervical spondylotic myelopathy patients who underwent cervical laminoplasty. Eur Radiol 2024; 34:1349-1357. [PMID: 37581664 DOI: 10.1007/s00330-023-10011-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2022] [Revised: 05/01/2023] [Accepted: 06/08/2023] [Indexed: 08/16/2023]
Abstract
OBJECTIVES To investigate the association between spinal cord perfusion and microstructural damage in CSM patients who underwent cervical laminoplasty using MR dynamic susceptibility contrast (DSC), diffusion tensor imaging (DTI), and neurite orientation dispersion and density imaging (NODDI) techniques. METHODS A follow-up cohort study was conducted with 53 consecutively recruited CSM patients who had undergone cervical laminoplasty 12-14 months after the surgery from April 2016 to December 2016. Twenty-one aged-matched healthy volunteers were recruited as controls. For each patient, decompressed spinal cord levels were imaged on a 3.0-T MRI scanner by diffusion and DSC sequences to quantify the degrees of microstructural damage and perfusion conditions, respectively. The diffusion data were analyzed by DTI and NODDI models to produce diffusion metrics. Classic indicator dilution model was used to quantify the DSC metrics. Mann-Whitney U test was performed for comparison of diffusion metrics between patients and healthy controls. Pearson correlation was used to explore the associations between the metrics of spinal cord perfusion and microstructural damage. RESULTS DTI metrics, neurite density, and isotropic volume fraction had significant differences between postoperative patients and healthy controls. Pearson correlation test showed that SCBV was significantly positively correlated with RD, MD, and ODI, and negatively correlated with FA and NDI. SCBF was found to be significantly positively correlated with RD and MD, and negatively correlated with FA. CONCLUSIONS Increased spinal cord perfusion quantified by DSC is associated with microstructural damage assessed by diffusion MRI in CSM patients who underwent cervical laminoplasty. CLINICAL RELEVANCE STATEMENT This study found that the spinal cord perfusion is associated with microstructural damage in postoperative cervical spondylotic myelopathy patients, indicating that high perfusion may play a role in the pathophysiological process of cervical spondylotic myelopathy and deserves more attention. KEY POINTS • Spinal cord microstructural damage can be persistent despite the compression had been relieved 12-14 months after the cervical laminoplasty in cervical spondylotic myelopathy (CSM) patients. • Spinal cord perfusion is associated with microstructural damage in CSM patients after the cervical laminoplasty. • Inflammation in the decompressed spinal cord may be a cause of increased perfusion and is associated with microstructural damage during the recovery period of CSM.
Collapse
Affiliation(s)
- Chunyao Wang
- Center for Biomedical Imaging Research, Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, China
| | - Xiao Han
- Department of Spine Surgery, Beijing Jishuitan Hospital, Capital Medical University, Beijing, China
- Beijing Research Institute of Traumatology and Orthopaedics, Beijing, China
| | - Xiaodong Ma
- Center for Magnetic Resonance Research, Radiology, Medical School of the University of Minnesota, Minnesota, USA
| | - Wen Jiang
- Department of Radiology, Beijing Jishuitan Hospital, Capital Medical University, Beijing, China
| | - Jinchao Wang
- Department of Spine Surgery, Beijing Jishuitan Hospital, Capital Medical University, Beijing, China
| | - Sisi Li
- Center for Biomedical Imaging Research, Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, China
| | - Hua Guo
- Center for Biomedical Imaging Research, Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, China
| | - Wei Tian
- Department of Spine Surgery, Beijing Jishuitan Hospital, Capital Medical University, Beijing, China.
| | - Huijun Chen
- Center for Biomedical Imaging Research, Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, China.
| |
Collapse
|
2
|
Lévy S, Roche PH, Guye M, Callot V. Feasibility of human spinal cord perfusion mapping using dynamic susceptibility contrast imaging at 7T: Preliminary results and identified guidelines. Magn Reson Med 2020; 85:1183-1194. [PMID: 33151009 DOI: 10.1002/mrm.28559] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2020] [Revised: 09/28/2020] [Accepted: 09/29/2020] [Indexed: 12/14/2022]
Abstract
PURPOSE To explore the feasibility of dynamic susceptibility contrast MRI at 7 Tesla for human spinal cord perfusion mapping and fill the gap between brain and spinal cord perfusion mapping techniques. METHODS Acquisition protocols for high-resolution single shot EPI in the spinal cord were optimized for both spin-echo and gradient-echo preparations, including cardiac gating, acquisition times and breathing cycle recording. Breathing-induced MRI signal fluctuations were investigated in healthy volunteers. A specific image- and signal-processing pipeline was implemented to address them. Dynamic susceptibility contrast was then evaluated in 3 healthy volunteers and 5 patients. Bolus depiction on slice-wise signal within cord was investigated, and maps of relative perfusion indices were computed. RESULTS Signal fluctuations were increased by 1.9 and 2.3 in free-breathing compared to apnea with spin-echo and gradient-echo, respectively. The ratio between signal fluctuations and bolus peak in healthy volunteers was 5.0% for spin-echo and 3.8% for gradient-echo, allowing clear depiction of the bolus on every slice and yielding relative blood flow and volume maps exhibiting the expected higher perfusion of gray matter. However, signal fluctuations in patients were increased by 4 in average (using spin-echo), compromising the depiction of the bolus in slice-wise signal. Moreover, 3 of 18 slices had to be discarded because of fat-aliasing artifacts. CONCLUSION Dynamic susceptibility contrast MRI at 7 Tesla showed great potential for spinal cord perfusion mapping with a reliability never achieved thus far for single subject and single slice measurements. Signal stability needs to be improved in acquisition conditions associated with patients; guidelines to achieve that have been identified and shared.
Collapse
Affiliation(s)
- Simon Lévy
- Aix-Marseille Univ, CNRS, CRMBM, Marseille, France.,APHM, Hopital Universitaire Timone, CEMEREM, Marseille, France.,Aix-Marseille Univ, Univ Gustave Eiffel, LBA, Marseille, France.,iLab-Spine International Associated Laboratory, Marseille-Montreal, France-Canada
| | - Pierre-Hugues Roche
- iLab-Spine International Associated Laboratory, Marseille-Montreal, France-Canada.,Neurosurgery Department, APHM, Hopital Nord, Marseille, France
| | - Maxime Guye
- Aix-Marseille Univ, CNRS, CRMBM, Marseille, France.,APHM, Hopital Universitaire Timone, CEMEREM, Marseille, France
| | - Virginie Callot
- Aix-Marseille Univ, CNRS, CRMBM, Marseille, France.,APHM, Hopital Universitaire Timone, CEMEREM, Marseille, France.,iLab-Spine International Associated Laboratory, Marseille-Montreal, France-Canada
| |
Collapse
|
3
|
Yablonskiy DA, Sukstanskii AL, He X. Blood oxygenation level-dependent (BOLD)-based techniques for the quantification of brain hemodynamic and metabolic properties - theoretical models and experimental approaches. NMR IN BIOMEDICINE 2013; 26:963-86. [PMID: 22927123 PMCID: PMC3510357 DOI: 10.1002/nbm.2839] [Citation(s) in RCA: 106] [Impact Index Per Article: 9.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/22/2012] [Revised: 06/19/2012] [Accepted: 06/22/2012] [Indexed: 05/06/2023]
Abstract
The quantitative evaluation of brain hemodynamics and metabolism, particularly the relationship between brain function and oxygen utilization, is important for the understanding of normal human brain operation, as well as the pathophysiology of neurological disorders. It can also be of great importance for the evaluation of hypoxia within tumors of the brain and other organs. A fundamental discovery by Ogawa and coworkers of the blood oxygenation level-dependent (BOLD) contrast opened up the possibility to use this effect to study brain hemodynamic and metabolic properties by means of MRI measurements. Such measurements require the development of theoretical models connecting the MRI signal to brain structure and function, and the design of experimental techniques allowing MR measurements to be made of the salient features of theoretical models. In this review, we discuss several such theoretical models and experimental methods for the quantification of brain hemodynamic and metabolic properties. The review's main focus is on methods for the evaluation of the oxygen extraction fraction (OEF) based on the measurement of the blood oxygenation level. A combination of the measurement of OEF and the cerebral blood flow (CBF) allows an evaluation to be made of the cerebral metabolic rate of oxygen consumption (CMRO2 ). We first consider in detail the magnetic properties of blood - magnetic susceptibility, MR relaxation and theoretical models of the intravascular contribution to the MR signal under different experimental conditions. We then describe a 'through-space' effect - the influence of inhomogeneous magnetic fields, created in the extravascular space by intravascular deoxygenated blood, on the formation of the MR signal. Further, we describe several experimental techniques taking advantage of these theoretical models. Some of these techniques - MR susceptometry and T2 -based quantification of OEF - utilize the intravascular MR signal. Another technique - quantitative BOLD - evaluates OEF by making use of through-space effects. In this review, we target both scientists just entering the MR field and more experienced MR researchers interested in the application of advanced BOLD-based techniques to the study of the brain in health and disease.
Collapse
|
4
|
Jones J, Lerner A, Kim PE, Law M, Hsieh PC. Diffusion tensor imaging in the assessment of ossification of the posterior longitudinal ligament: a report on preliminary results in 3 cases and review of the literature. Neurosurg Focus 2012; 30:E14. [PMID: 21361752 DOI: 10.3171/2011.1.focus10262] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Cervical spondylotic myelopathy due to ossification of the posterior longitudinal ligament (OPLL) is a common neurosurgical disease that carries high morbidity. OPLL and other degenerative processes cause narrowing of the central canal, with subsequent spinal cord injury. Repeated minor trauma and vascular aberrations have been purported to underlie cervical spondylotic myelopathy, although the exact pathophysiological mechanism is unclear. Regardless, detection of early axonal damage may allow more timely surgical intervention and prediction of functional outcome. Diffusion tensor (DT) imaging of the cervical spine is a novel technique with improved sensitivity compared with conventional anatomical MR imaging that is currently available on most clinical scanners. This review describes the theoretical basis, application, and analysis of DT imaging as it pertains to neurosurgery. Particular emphasis is placed on OPLL.
Collapse
Affiliation(s)
- Jesse Jones
- Department of Neurosurgery, University of Southern California, Los Angeles, CA, USA.
| | | | | | | | | |
Collapse
|
5
|
Spampinato MV, Bisdas S, Sharma AK, McDonald D, Strojan P, Rumboldt Z. Computed Tomography Perfusion Assessment of Radiation Therapy Effects on Spinal Cord Hemodynamics. Int J Radiat Oncol Biol Phys 2010; 77:851-7. [DOI: 10.1016/j.ijrobp.2009.05.060] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2008] [Revised: 05/26/2009] [Accepted: 05/29/2009] [Indexed: 11/16/2022]
|
6
|
Wåhlin A, Ambarki K, Birgander R, Alperin N, Malm J, Eklund A. Assessment of craniospinal pressure-volume indices. AJNR Am J Neuroradiol 2010; 31:1645-50. [PMID: 20595369 DOI: 10.3174/ajnr.a2166] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
BACKGROUND AND PURPOSE The PVI(CC) of the craniospinal compartment defines the shape of the pressure-volume curve and determines the damping of cyclic arterial pulsations. Despite no reports of direct measurements of the PVI(CC) among healthy elderly, it is believed that a change away from adequate accommodation of cardiac-related pulsations may be a pathophysiologic mechanism seen in neurodegenerative disorders such as Alzheimer disease and idiopathic normal pressure hydrocephalus. In this study, blood and CSF flow measurements are combined with lumbar CSF infusion measurements to assess the craniospinal PVI(CC) and its distribution of cranial and spinal compartments in healthy elderly. MATERIALS AND METHODS Thirty-seven healthy elderly were included (60-82 years of age). The cyclic arterial volume change and the resulting shift of CSF to the spinal compartment were quantified by PC-MR imaging. In addition, each subject underwent a lumbar CSF infusion test in which the magnitude of cardiac-related pulsations in intracranial pressure was quantified. Finally, the PVI was calculated by using a mathematic model. RESULTS After excluding 2 extreme values, the craniospinal PVI(CC) was calculated to a mean of 9.8 ± 2.7 mL and the estimated average 95% confidence interval of individual measurements was ± 9%. The average intracranial and spinal contributions to the overall compliance were 65% and 35% respectively (n = 35). CONCLUSIONS Combining lumbar CSF infusion and PC-MR imaging proved feasible and robust for assessment of the craniospinal PVI(CC). This study produced normative values and showed that the major compensatory contribution was located intracranially.
Collapse
Affiliation(s)
- A Wåhlin
- Department of Radiation Sciences, Umeå University, Umeå, Sweden.
| | | | | | | | | | | |
Collapse
|
7
|
Cheng Z, Thorek DLJ, Tsourkas A. Porous Polymersomes with Encapsulated Gd-labeled Dendrimers as Highly Efficient MRI Contrast Agents. ADVANCED FUNCTIONAL MATERIALS 2009; 19:3753-3759. [PMID: 23293575 PMCID: PMC3536029 DOI: 10.1002/adfm.200901253] [Citation(s) in RCA: 67] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
The use of nanovesicles with encapsulated Gd as MR contrast agents has largely been ignored due to the detrimental effects of the slow water exchange rate through the vesicle bilayer on the relaxivity of encapsulated Gd. Here, we describe the facile synthesis of a composite MR contrast platform, consisting of dendrimer conjugates encapsulated in porous polymersomes. These nanoparticles exhibit improved permeability to water flux and a large capacity to store chelated Gd within the aqueous lumen, resulting in enhanced longitudinal relaxivity. The porous polymersomes, ~130 nm in diameter, were produced through the aqueous assembly of the polymers, polyethylene oxide-b-polybutadiene (PBdEO), and polyethylene oxide-b-polycaprolactone (PEOCL). Subsequent hydrolysis of the caprolactone (CL) block resulted in a highly permeable outer membrane. To prevent the leakage of small Gd-chelate through the pores, Gd was conjugated to PAMAM dendrimer via diethylenetriaminepentaacetic acid dianhydride (DTPA dianhydride) prior to encapsulation. As a result of the slower rotational correlation time of Gd-labeled dendrimers, the porous outer membrane of the nanovesicle, and the high Gd payload, these functional nanoparticles were found to exhibit a relaxivity (R1) of 292,109 mM(-1) s(-1) per particle. The polymersomes were also found to exhibit unique pharmacokinetics with a circulation half-life of >3.5 hrs and predominantly renal clearance.
Collapse
Affiliation(s)
- Zhiliang Cheng
- Department of Bioengineering, University of Pennsylvania 210 South 33rd Street, 240 Skirkanich Hall, Philadelphia, PA 19104 (USA)
| | | | | |
Collapse
|
8
|
Perfusion CT measurements in healthy cervical spinal cord: feasibility and repeatability of the study as well as interchangeability of the perfusion estimates using two commercially available software packages. Eur Radiol 2008; 18:2321-8. [PMID: 18431576 DOI: 10.1007/s00330-008-0973-2] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2007] [Accepted: 03/16/2008] [Indexed: 10/22/2022]
Abstract
Our purpose was to examine the feasibility and reproducibility of perfusion CT studies in the cervical spinal cord and the interchangeability of the values obtained by two post-processing methods. The perfusion CT studies of 40 patients with neck tumours were post-processed using two software packages (Software-1: deconvolution-based analysis with adiabatic tissue homogeneity approach and Software-2: maximum-slope-model with Patlak analysis). Eight patients were examined twice for assessing the reproducibility of the technique. Two neuroradiologists separately post-processed the images with two arterial input functions (AIFs): (1) the internal carotid artery (ICA) and (2) the vertebral artery (VA). Maps of blood flow (F) in ml/min/100 g, blood volume (V) in ml/100 g, mean transit time (MTT) in seconds (s) and permeability (PS) in ml/min/100 g were generated. The mean F, V, MTT and PS (Software-1) with VA-AIF and ICA-AIF were 8.93, 1.12, 16.3, 1.88 and 8.57, 1.19, 16.85 and 1.94, respectively. The reproducibility of the techniques was satisfactory, while the V and MTT values (in Software-1) and the F and V values (in Software-2) were dependent on the site of the AIF (p >or= 0.03 and p=0.02, respectively). The interobserver agreement was very good. The significant differences in measurements for a single patient (%) using Software-1/Software-2 were +/-120%/110%, 90%/80%, 180% and 250%/130% for F, V, MTT and PS, respectively. Only F and PS values in the healthy tissue seemed to be interchangeable. Our results were in essential agreement with those derived by invasive measurements in animals. The cervical spine perfusion CT studies are feasible and reproducible. The present knowledge has to be validated with studies in spinal cord tumours in order to decide the usefulness of the perfusion CT in this field.
Collapse
|