1
|
Nascimento MS, Leite FS, Silva PAL, Zamberlan GC, de Souza PM, Eid RAC, Zacharias RSB, do Prado C, Batista CL. Reliability and reference values for diaphragmatic excursion, thickness, and thickening fraction and quadriceps femoris muscle thickness in full-term newborns evaluated by ultrasound. Eur J Pediatr 2024; 183:3453-3460. [PMID: 38771374 DOI: 10.1007/s00431-024-05608-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/04/2024] [Revised: 05/06/2024] [Accepted: 05/11/2024] [Indexed: 05/22/2024]
Abstract
To determine the diaphragm thickness, thickening fraction, and excursion and thickness of the quadriceps femoris muscle in full-term newborns and to evaluate the intra- and interrater reliability of these measurements. This was a prospective, observational clinical study including full-term newborns born within the first 48 h after birth. Serial measurements of the thickness, thickening fraction, and mobility of the diaphragm muscles and the thickness of the quadriceps muscle were obtained using ultrasound images. A total of 69 newborns with a mean gestational age of 39 weeks were included. The following measurements were obtained and are expressed as the mean (standard deviation): inspiratory diaphragm thickness, 0.19 cm (0.04); expiratory diaphragm thickness, 0.16 cm (0.04); diaphragm thickness fraction, 16.70 cm (10.27); diaphragmatic excursion, 0.68 cm (0.22); and quadriceps thickness, 0.99 cm (0.14). Intrarater reliability was assessed using intraclass correlation coefficients (ICCs). Excellent intrarater agreement was observed for the two groups of operators (ICC > 0.86, p < 0.001) for all measurements except for the diaphragm thickening fraction, which showed good agreement for both operator groups (ICC = 0.70, p < 0.001). Regarding interrater reliability, moderate agreement between the raters was observed in the means of all measures (ICC > 0.49, p < 0.001), except for the diaphragm thickening fraction, which showed poor agreement. Conclusion: Good intrarater and moderate interrater reliability were achieved in ultrasound evaluations of the thickness and mobility of the diaphragm and quadriceps femoris muscles in full-term newborns, demonstrating the feasibility of this technique for clinical use. This pioneering study offers reference values for these muscles in a single study, allowing comparisons between different clinical conditions. What is Known: • Ultrasound is a highly reliable tool for muscle assessment that can be used to assess muscular atrophy in critically ill patients. • Muscle atrophy worsens the patient's condition and has been associated with worse outcomes. What is New: • To our knowledge, this is the first study to jointly evaluate the diaphragm and quadriceps muscle thickness and evaluate the reliability of all measurements. • Our study presents reference values for both muscles, enabling comparisons between different clinical conditions.
Collapse
Affiliation(s)
- Milena Siciliano Nascimento
- Departamento de Práticas Assistenciais, Hospital Israelita Albert Einstein, Avenue Albert Einstein, 627-701, 05651-901, São Paulo, Brazil.
| | - Flávia Sales Leite
- Departamento de Pacientes Graves, Hospital Israelita Albert Einstein, São Paulo, Brazil
| | | | | | - Priscila Monteiro de Souza
- Departamento de Práticas Assistenciais, Hospital Israelita Albert Einstein, Avenue Albert Einstein, 627-701, 05651-901, São Paulo, Brazil
- Corpo Discente da Faculdade Israelita de Ciências da Saúde Albert Einstein, São Paulo, Brazil
| | | | | | - Cristiane do Prado
- Departamento Materno-infantil, Hospital Israelita Albert Einstein, São Paulo, Brazil
| | - Carla Luciana Batista
- Departamento de Pacientes Graves, Hospital Israelita Albert Einstein, São Paulo, Brazil
| |
Collapse
|
2
|
Cheong I, Imbelloni MI, Gómez RA, Álvarez Vilariño FM, Baiona GA, Tamagnone FM. Non-invasive diagnosis of diaphragmatic paralysis in botulism using ultrasound. Toxicon 2024; 239:107609. [PMID: 38216093 DOI: 10.1016/j.toxicon.2024.107609] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2023] [Revised: 12/26/2023] [Accepted: 01/08/2024] [Indexed: 01/14/2024]
Abstract
This case study explores foodborne botulism, a severe illness caused by botulinum neurotoxin-contaminated food. It leads to bilateral descending paralysis, involving the diaphragm. We highlight diaphragmatic ultrasound as a non-invasive diagnostic tool. A 50-year-old obese male developed diplopia and weakness after consuming contaminated food, rapidly progressing to severe symptoms. Mechanical ventilation became necessary due to respiratory failure. Diaphragmatic ultrasound confirmed bilateral diaphragm paralysis despite early antitoxin treatment. The patient experienced complications, requiring tracheostomy and rehabilitation. After five months, he fully recovered diaphragmatic function. This study underscores botulism's life-threatening nature and the vital role of supportive care. Diaphragmatic ultrasound is a safe and effective method for assessing diaphragmatic function in such cases, obviating ionizing radiation exposure. We recommend its routine use for evaluating botulism-induced paralysis.
Collapse
Affiliation(s)
- Issac Cheong
- Department of Critical Care Medicine, Sanatorio de Los Arcos, Buenos Aires, Argentina; Argentinian Critical Care Ultrasonography Association (ASARUC), Argentina.
| | - Mariano Iván Imbelloni
- Department of Critical Care, Clínica de Internación Aguda en Rehabilitación y Cirugía (CIAREC), Buenos Aires, Argentina
| | - Raúl Alejandro Gómez
- Department of Critical Care Medicine, Sanatorio de Los Arcos, Buenos Aires, Argentina
| | | | - Gastón Adrián Baiona
- Department of Critical Care Medicine, Sanatorio de Los Arcos, Buenos Aires, Argentina; Department of Critical Care, Clínica de Internación Aguda en Rehabilitación y Cirugía (CIAREC), Buenos Aires, Argentina
| | | |
Collapse
|
3
|
Lapp HS, Freigang M, Hagenacker T, Weiler M, Wurster CD, Günther R. Biomarkers in 5q-associated spinal muscular atrophy-a narrative review. J Neurol 2023; 270:4157-4178. [PMID: 37289324 PMCID: PMC10421827 DOI: 10.1007/s00415-023-11787-y] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2023] [Revised: 05/15/2023] [Accepted: 05/16/2023] [Indexed: 06/09/2023]
Abstract
5q-associated spinal muscular atrophy (SMA) is a rare genetic disease caused by mutations in the SMN1 gene, resulting in a loss of functional SMN protein and consecutive degeneration of motor neurons in the ventral horn. The disease is clinically characterized by proximal paralysis and secondary skeletal muscle atrophy. New disease-modifying drugs driving SMN gene expression have been developed in the past decade and have revolutionized SMA treatment. The rise of treatment options led to a concomitant need of biomarkers for therapeutic guidance and an improved disease monitoring. Intensive efforts have been undertaken to develop suitable markers, and numerous candidate biomarkers for diagnostic, prognostic, and predictive values have been identified. The most promising markers include appliance-based measures such as electrophysiological and imaging-based indices as well as molecular markers including SMN-related proteins and markers of neurodegeneration and skeletal muscle integrity. However, none of the proposed biomarkers have been validated for the clinical routine yet. In this narrative review, we discuss the most promising candidate biomarkers for SMA and expand the discussion by addressing the largely unfolded potential of muscle integrity markers, especially in the context of upcoming muscle-targeting therapies. While the discussed candidate biomarkers hold potential as either diagnostic (e.g., SMN-related biomarkers), prognostic (e.g., markers of neurodegeneration, imaging-based markers), predictive (e.g., electrophysiological markers) or response markers (e.g., muscle integrity markers), no single measure seems to be suitable to cover all biomarker categories. Hence, a combination of different biomarkers and clinical assessments appears to be the most expedient solution at the time.
Collapse
Affiliation(s)
- H S Lapp
- Department of Neurology, University Hospital Carl Gustav Carus at TU Dresden, Fetscherstraße 74, 01307, Dresden, Germany
| | - M Freigang
- Department of Neurology, University Hospital Carl Gustav Carus at TU Dresden, Fetscherstraße 74, 01307, Dresden, Germany
| | - T Hagenacker
- Department of Neurology and Center for Translational Neuro- and Behavioral Science (C-TNBS), University Medicine Essen, Essen, Germany
| | - M Weiler
- Department of Neurology, Heidelberg University Hospital, Heidelberg, Germany
| | - C D Wurster
- Department of Neurology, University Hospital Ulm, Ulm, Germany
- German Center for Neurodegenerative Diseases (DZNE) Ulm, Ulm, Germany
| | - René Günther
- Department of Neurology, University Hospital Carl Gustav Carus at TU Dresden, Fetscherstraße 74, 01307, Dresden, Germany.
- German Center for Neurodegenerative Diseases (DZNE) Dresden, Dresden, Germany.
| |
Collapse
|
4
|
Freigang M, Langner S, Hermann A, Günther R. Impaired diaphragmatic motility in treatment-naive adult patients with spinal muscular atrophy improved during nusinersen treatment. Muscle Nerve 2023; 68:278-285. [PMID: 37466180 DOI: 10.1002/mus.27938] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2022] [Revised: 06/22/2023] [Accepted: 06/23/2023] [Indexed: 07/20/2023]
Abstract
INTRODUCTION/AIMS The leading clinical feature of 5q-associated spinal muscular atrophy (SMA) is symmetric, proximal muscle weakness. Muscles involved in ventilation exhibit a specific pattern of denervation: intercostal muscles are severely atrophic, whereas the diaphragm muscle is less affected. The aim of this study was to investigate the involvement of diaphragmatic function by ultrasound imaging in adult patients with SMA and to quantify dynamics of diaphragmatic function during nusinersen treatment. METHODS Diaphragmatic thickness, thickening, and excursion during quiet breathing were assessed in 24 adult patients with SMA type 2 and 3 by diaphragm ultrasound imaging before and during nusinersen treatment and were correlated with spirometric parameters. RESULTS Diaphragm thickness was not reduced, but increased in a remarkable proportion of patients, whereas diaphragm thickening and excursion were reduced in about 20% to 30% of nusinersen-naive, adult patients with SMA types 2 and 3. During 26 months of nusinersen treatment, diaphragm thickening fraction and excursion improved. DISCUSSION Diaphragm ultrasound imaging can provide disease- and treatment-relevant information that is not identified during routine clinical assessments and may therefore be a valuable complementary outcome measure.
Collapse
Affiliation(s)
- Maren Freigang
- Department of Neurology, University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany
| | - Simona Langner
- Division of Pulmonology, Medical Department I, University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany
| | - Andreas Hermann
- Translational Neurodegeneration Section "Albrecht-Kossel," Department of Neurology, University Medical Center Rostock, University of Rostock, Rostock, Germany
- Center for Transdisciplinary Neurosciences Rostock, University Medical Center Rostock, University of Rostock, Rostock, Germany
- Deutsches Zentrum für Neurodegenerative Erkrankungen Rostock/Greifswald, Rostock, Germany
| | - René Günther
- Department of Neurology, University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany
- Deutsches Zentrum für Neurodegenerative Erkrankungen Dresden, Dresden, Germany
| |
Collapse
|
5
|
Moreira AL, Mendonça RH, Polido GJ, Oliveira MCB, Silva AMS, Zanoteli E. Muscle Ultrasound Changes Correlate With Functional Impairment in Spinal Muscular Atrophy. ULTRASOUND IN MEDICINE & BIOLOGY 2023; 49:1569-1574. [PMID: 37037685 DOI: 10.1016/j.ultrasmedbio.2023.02.021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/11/2022] [Revised: 02/18/2023] [Accepted: 02/28/2023] [Indexed: 05/17/2023]
Abstract
OBJECTIVE We investigated ultrasound patterns of muscle involvement in different types of spinal muscular atrophy (SMA) and their correlation with functional status to determine the pattern of muscle compromise in patients with SMA and the potential role of ultrasound to evaluate disease progression. METHODS We examined muscles (biceps brachii, rectus femoris, diaphragm, intercostals and thoracic multifidus) of 41 patients with SMA (types 1 to 4) and 46 healthy age- and sex-matched control individuals using B-mode ultrasound for gray-scale analysis (GSA), area (biceps brachii and rectus femoris) and diaphragm thickening ratio. Functional scales were applied to patients only. We analyzed ultrasound abnormalities in specific clinical subtypes and correlated findings with functional status. RESULTS Compared with controls, patients had reduced muscle area and increased mean GSA for all muscles (p < 0.001), with an established correlation between the increase in GSA and the severity of SMA for biceps brachii, rectus femoris and intercostals (p = 0.03, 0.01 and 0.004 respectively) when using the Hammersmith Functional Motor Scale Expanded. Diaphragm thickening ratio was normal in the majority of patients, and intercostal muscles had higher GSA than diaphragm in relation to the controls. CONCLUSION Ultrasound is useful for quantifying muscular changes in SMA and correlates with functional status. Diaphragm thickening ratio can be normal even with severe compromise of respiratory muscles in quantitative analysis, and intercostal muscles were more affected than diaphragm.
Collapse
Affiliation(s)
- Ana Lucila Moreira
- Departament of Neurology, Faculdade de Medicina da Universidade de São Paulo, São Paulo, Brazil.
| | | | - Graziela Jorge Polido
- Departament of Neurology, Faculdade de Medicina da Universidade de São Paulo, São Paulo, Brazil
| | | | | | - Edmar Zanoteli
- Departament of Neurology, Faculdade de Medicina da Universidade de São Paulo, São Paulo, Brazil
| |
Collapse
|
6
|
Buonsenso D, Mariani F, Morello R, Cammarota G, De Rose C, Valentini P, Camporesi A, Vetrugno L. Ultrasound Imaging for Diaphragm Function in a Population of Healthy Infants: A Short Observational Report. Diagnostics (Basel) 2023; 13:diagnostics13061095. [PMID: 36980403 PMCID: PMC10047558 DOI: 10.3390/diagnostics13061095] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2023] [Revised: 03/07/2023] [Accepted: 03/10/2023] [Indexed: 03/16/2023] Open
Abstract
Introduction: Diaphragm ultrasound is increasingly used in adults, and more recently in pediatric practice. However, normal diaphragm parameters in healthy infants are unknown. This was a prospective observational pilot study aiming to define the normal diaphragm ultrasound characteristics in healthy infants during the first 6 months of life. Methods: We recruited healthy neonates at 7 to 15 days of life, who were followed until the sixth month of life, undergoing five assessments in different time points. The measurements included diaphragm thickness at end expiration (TEE) and at end inspiration (TEI). The thickening fraction (TF) was calculated as (TEI-TEE)/TEE and expressed as a percentage, and as (TEI-TEE)/TEI. Results: A total of 37 toddlers, 16 of which were females (43.2%), were enrolled. Thirty-four children (91.9%) were of Caucasian ethnicity and the median gestational age was 38.4 (35.7–40) weeks. Normal TEE, TEI, and TF have been provided for each time point. Conclusion: We provided new insight regarding data about thickness and thickening function in healthy children to be used for future physiologic and pathologic pediatric studies.
Collapse
Affiliation(s)
- Danilo Buonsenso
- Department of Woman and Child Health and Public Health, Fondazione Policlinico Universitario A. Gemelli IRCCS, Largo A. Gemelli 8, 00168 Rome, Italy
- Centro di Salute Globale, Università Cattolica del Sacro Cuore, 00168 Rome, Italy
- Correspondence: ; Tel.: +39-0630154390
| | - Francesco Mariani
- Department of Woman and Child Health and Public Health, Fondazione Policlinico Universitario A. Gemelli IRCCS, Largo A. Gemelli 8, 00168 Rome, Italy
| | - Rosa Morello
- Department of Woman and Child Health and Public Health, Fondazione Policlinico Universitario A. Gemelli IRCCS, Largo A. Gemelli 8, 00168 Rome, Italy
| | - Gianmaria Cammarota
- Department of Anaesthesia and Intensive Care Medicine, University of Perugia, 06100 Perugia, Italy
| | - Cristina De Rose
- Department of Woman and Child Health and Public Health, Fondazione Policlinico Universitario A. Gemelli IRCCS, Largo A. Gemelli 8, 00168 Rome, Italy
| | - Piero Valentini
- Department of Woman and Child Health and Public Health, Fondazione Policlinico Universitario A. Gemelli IRCCS, Largo A. Gemelli 8, 00168 Rome, Italy
| | - Anna Camporesi
- Department of Pediatric Anesthesia and Intensive Care, Children’s Hospital “Vittore Buzzi”, 20154 Milan, Italy
| | - Luigi Vetrugno
- Department of Anesthesia, “SS Annunziata” Hospital, Via dei Vestini, 66100 Chieti, Italy
- Department of Medical, Oral and Biotechnological Sciences, University of Chieti-Pescara, 66100 Chieti, Italy
| |
Collapse
|
7
|
Alves RMR, Van Der Linden V, de Andrade LB. Comprehensive assessment model for patients with spinal muscular atrophy: proposal of tools for clinical practice and real-world studies. REVISTA DA ASSOCIACAO MEDICA BRASILEIRA (1992) 2023; 69:377-379. [PMID: 36820780 PMCID: PMC10004283 DOI: 10.1590/1806-9282.20221608] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/03/2022] [Accepted: 12/15/2022] [Indexed: 02/22/2023]
Affiliation(s)
- Renalli Manuella Rodrigues Alves
- Instituto de Medicina Integral Professor Fernando Figueira, Pós-graduação em Saúde Integral – Recife (PE), Brazil
- Hospital Otávio de Freitas, Departamento de Reabilitação – Recife (PE), Brazil
- Corresponding author:
| | - Vanessa Van Der Linden
- Hospital Maria Lucinda/Raros, Serviço de Doenças Raras – Recife (PE), Brazil
- Universidade Federal de Pernambuco, Centro de Ciências da Saúde – Recife (PE), Brazil
| | - Lívia Barbosa de Andrade
- Instituto de Medicina Integral Professor Fernando Figueira, Pós-graduação em Saúde Integral – Recife (PE), Brazil
| |
Collapse
|
8
|
Pałac M, Linek P. Intra-Rater Reliability of Shear Wave Elastography for the Quantification of Respiratory Muscles in Adolescent Athletes. SENSORS (BASEL, SWITZERLAND) 2022; 22:s22176622. [PMID: 36081075 PMCID: PMC9460867 DOI: 10.3390/s22176622] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/04/2022] [Revised: 08/25/2022] [Accepted: 08/29/2022] [Indexed: 05/09/2023]
Abstract
The aim of this study was to assess the intra-rater reliability and agreement of diaphragm and intercostal muscle elasticity and thickness during tidal breathing. The diaphragm and intercostal muscle parameters were measured using shear wave elastography in adolescent athletes. To calculate intra-rater reliability, intraclass correlation coefficient (ICC) and Bland-Altman statistics were used. The reliability/agreement for one-day both muscle measurements (regardless of probe orientation) were at least moderate. During the seven-day interval between measurements, the reliability of a single measurement depended on the measured parameter, transducer orientation, respiratory phase, and muscle. Excellent reliability was found for diaphragm shear modulus at the peak of tidal expiration in transverse probe position (ICC3.1 = 0.91-0.96; ICC3.2 = 0.95), and from poor to excellent reliability for the intercostal muscle thickness at the peak of tidal inspiration with the longitudinal probe position (ICC3.1 = 0.26-0.95; ICC3.2 = 0.15). The overall reliability/agreement of the analysed data was higher for the diaphragm measurements (than the intercostal muscles) regardless of the respiratory phase and probe position. It is difficult to identify a more appropriate probe position to examine these muscles. The shear modulus/thickness of the diaphragm and intercostal muscles demonstrated good reliability/agreement so this appears to be a promising technique for their examination in athletes.
Collapse
Affiliation(s)
- Małgorzata Pałac
- Musculoskeletal Elastography and Ultrasonography Laboratory, Institute of Physiotherapy and Health Sciences, The Jerzy Kukuczka Academy of Physical Education, 40-065 Katowice, Poland
- Musculoskeletal Diagnostic and Physiotherapy—Research Team, The Jerzy Kukuczka Academy of Physical Education, 40-065 Katowice, Poland
| | - Paweł Linek
- Musculoskeletal Elastography and Ultrasonography Laboratory, Institute of Physiotherapy and Health Sciences, The Jerzy Kukuczka Academy of Physical Education, 40-065 Katowice, Poland
- Musculoskeletal Diagnostic and Physiotherapy—Research Team, The Jerzy Kukuczka Academy of Physical Education, 40-065 Katowice, Poland
- Correspondence: ; Tel.: +48-661-768-601
| |
Collapse
|
9
|
Arslan G, Besci T, Duman M. Point of care diaphragm ultrasound in mechanically ventilated children: A predictive tool to detect extubation failure. Pediatr Pulmonol 2022; 57:1432-1439. [PMID: 35362674 DOI: 10.1002/ppul.25916] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/10/2022] [Revised: 03/29/2022] [Accepted: 03/30/2022] [Indexed: 11/11/2022]
Abstract
BACKGROUND Children should be weaned from the ventilator once their clinical condition improves. Extubation failure is associated with poorer clinical outcomes in children. Predictive indicators of successful extubation are needed. This study aims to evaluate the predictive value of ultrasonographic diaphragm imaging could help predict weaning success. METHODS In this prospective, observational study conducted between March and December 2021, children between 1 month and 10 years of age who were mechanically ventilated for more than 48 h were included. Diaphragm ultrasound (DUS) examinations were performed at the end of 2-h extubation readiness test (ERT). The end-inspiratory thickness (DTi), end-expiratory thickness (DTe), diaphragmatic thickening fraction (DTF), diaphragmatic excursion (DE), inspiratory slope (IS), and expiratory slope (ES) were evaluated. RESULTS Twenty-four (60%) patients were successfully extubated, while 16 (40%) required invasive or noninvasive mechanical ventilation support which were classified as failed extubation group. Three of the sixteen patients in the failed extubation group required reintubation. DTF was significantly greater in the successful weaning group (55.05 ± 23.75% vs. 30.9 ± 10.38%) (p < 0.001). DE was significantly greater in the successful weaning group (14 ± 4.4 mm vs. 11.05 ± 3.25 mm) (p < 0.001). DTF and DE were found to have a sensitivity and specificity of 91.67%, 87.50%, 83.33%, and 81.25%, respectively. CONCLUSION Diaphragm ultrasound is a feasible and promising tool to guide physicians during weaning from invasive mechanical ventilation. Among all DUS measurements, the DE and DTF indexes showed better performance in extubation failure than other diaphragmatic parameters.
Collapse
Affiliation(s)
- Gazi Arslan
- Division of Pediatric Intensive Care, Department of Pediatrics, Dokuz Eylul University School of Medicine, Izmir, Turkey
| | - Tolga Besci
- Division of Pediatric Intensive Care, Department of Pediatrics, Dokuz Eylul University School of Medicine, Izmir, Turkey
| | - Murat Duman
- Division of Pediatric Emergency, Department of Pediatrics, Dokuz Eylul University School of Medicine, Izmir, Turkey
| |
Collapse
|
10
|
Affection of Respiratory Muscles in ALS and SMA. J Clin Med 2022; 11:jcm11051163. [PMID: 35268254 PMCID: PMC8910994 DOI: 10.3390/jcm11051163] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2021] [Revised: 02/18/2022] [Accepted: 02/19/2022] [Indexed: 12/10/2022] Open
Abstract
Respiratory dysfunction is a common cause of morbidity and mortality in motor neuron disease (MND). However, classical volitional measures of respiratory function in these patients are impeded by, e.g., bulbar paralysis or progressive disability. Diaphragm ultrasound imaging might be a valuable tool for assessing respiratory impairment, albeit different ultrasound measures have not been systematically investigated in adult MND patients and, in particular, have not yet been comparatively applied in adult patients with amyotrophic lateral sclerosis (ALS) and spinal muscular atrophy (SMA). We hypothesized that in contrast to ALS patients, adult SMA patients show a relative sparing of diaphragm function. We retrospectively analyzed diaphragm ultrasound imaging data of 40 patients with ALS and 23 patients with SMA in comparison to a multitude of established parameters of respiratory function. Indeed, ALS patients showed more severe diaphragm dysfunction than adult SMA patients, however, diaphragm dysfunction was also common in adult SMA patients. Notably, dynamic measures of diaphragm function rather than thickness measures were impaired in ALS compared to SMA. Thus, diaphragm ultrasound imaging might be a useful tool to evaluate respiratory dysfunction in adult MND patients. Future larger and prospective studies are needed to validate our initial findings.
Collapse
|
11
|
Diaphragmatic Point-of-Care Ultrasound in COVID-19 Patients in the Emergency Department-A Proof-of-Concept Study. J Clin Med 2021; 10:jcm10225291. [PMID: 34830573 PMCID: PMC8623129 DOI: 10.3390/jcm10225291] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2021] [Revised: 11/08/2021] [Accepted: 11/10/2021] [Indexed: 02/06/2023] Open
Abstract
Background: Lung Ultrasound Evaluation (LUS) is usefully applied in the Emergency Department (ED) to patients with suspected or confirmed COVID-19. Diaphragmatic Ultrasound (DUS) may provide additional insight into ventilatory function. This proof-of-concept study aimed to evaluate the feasibility of LUS and DUS in a third level ED during the COVID-19 pandemic. Methods: Adult patients presenting with COVID-19 symptoms were eligible. After the physical examination, both LUS and DUS (i.e., diaphragmatic motion and thickness) were performed. All patients were followed after 30 days to determine their need for ventilation, admission, and/or a new ED evaluation after discharge. The diagnostic accuracies of diaphragm measurements in assessing the risk of the 30-day outcome were calculated as well as the measurements’ usefulness. Bland–Altman plots were used for comparing bedside and off-line diaphragm measurements. Results: 118 patients were enrolled. Median thickness and motion were 1.7 mm (iqr 0.4) and 1.8 cm (iqr 0.7), respectively, with a mean difference of 0.009 mm (95% CI −0.037–0.056 mm) and −0.051 cm (95% CI −0.108–0.006 cm), respectively. The 30-day outcome was associated with an increase in thickness (OR 5.84, 95% CI 0.96–35.4), and a lower motion (OR 0.49, 95% CI 0.2–1.21). Conclusion: DUS seemed to be feasible and reliable in the ED in a population of patients presenting with symptoms related to COVID-19 infection.
Collapse
|
12
|
Weber MD, Lim JKB, Glau C, Conlon T, James R, Lee JH. A narrative review of diaphragmatic ultrasound in pediatric critical care. Pediatr Pulmonol 2021; 56:2471-2483. [PMID: 34081825 DOI: 10.1002/ppul.25518] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/15/2021] [Revised: 05/18/2021] [Accepted: 05/21/2021] [Indexed: 01/20/2023]
Abstract
The use of point of care ultrasound (POCUS) at the bedside has increased dramatically within emergency medicine and in critical care. Applications of POCUS have spread to include diaphragmatic assessments in both adults and children. Diaphragm POCUS can be used to assess for diaphragm dysfunction (DD) and atrophy or to guide ventilator titration and weaning. Quantitative, semi-quantitative and qualitative measurements of diaphragm thickness, diaphragm excursion, and diaphragm thickening fraction provide objective data related to DD and atrophy. The potential for quick, noninvasive, and repeatable bedside diaphragm assessments has led to a growing amount of literature on diaphragm POCUS. To date, there are no reviews of the current state of diaphragm POCUS in pediatric critical care. The aims of this narrative review are to summarize the current literature regarding techniques, reference values, applications, and future innovations of diaphragm POCUS in critically ill children. A summary of current practice and future directions will be discussed.
Collapse
Affiliation(s)
- Mark D Weber
- Department of Anesthesiology and Critical Care Medicine, Children's Hospital of Philadelphia, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Joel K B Lim
- Children's Intensive Care Unit, Department of Pediatric Subspecialties, KK Women's and Children's Hospital, Singapore, Singapore
| | - Christie Glau
- Department of Anesthesiology and Critical Care Medicine, Children's Hospital of Philadelphia, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Thomas Conlon
- Department of Anesthesiology and Critical Care Medicine, Children's Hospital of Philadelphia, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Richard James
- University of Pennsylvania Biomedical Library, Philadelphia, Pennsylvania, USA
| | - Jan Hau Lee
- Children's Intensive Care Unit, Department of Pediatric Subspecialties, KK Women's and Children's Hospital, Singapore, Singapore.,Duke-NUS Medical School, Singapore, Singapore
| |
Collapse
|
13
|
van Doorn JLM, Pennati F, Hansen HHG, van Engelen BGM, Aliverti A, Doorduin J. Respiratory muscle imaging by ultrasound and MRI in neuromuscular disorders. Eur Respir J 2021; 58:13993003.00137-2021. [PMID: 33863737 DOI: 10.1183/13993003.00137-2021] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2021] [Accepted: 03/26/2021] [Indexed: 11/05/2022]
Abstract
Respiratory muscle weakness is common in neuromuscular disorders and leads to significant respiratory difficulties. Therefore, reliable and easy assessment of respiratory muscle structure and function in neuromuscular disorders is crucial. In the last decade, ultrasound and MRI emerged as promising imaging techniques to assess respiratory muscle structure and function. Respiratory muscle imaging directly measures the respiratory muscles and, in contrast to pulmonary function testing, is independent of patient effort. This makes respiratory muscle imaging suitable to use as tool in clinical respiratory management and as outcome parameter in upcoming drug trials for neuromuscular disorders, particularly in children. In this narrative review, we discuss the latest studies and technological developments in imaging of the respiratory muscles by US and MR, and its clinical application and limitations. We aim to increase understanding of respiratory muscle imaging and facilitate its use as outcome measure in daily practice and clinical trials.
Collapse
Affiliation(s)
- Jeroen L M van Doorn
- Department of Neurology, Donders Institute for Brain, Cognition and Behavior, Radboud University Medical Center, Nijmegen, the Netherlands
| | - Francesca Pennati
- Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, Milan, Italy
| | - Hendrik H G Hansen
- Department of Medical Imaging, Medical Ultrasound Imaging Center (MUSIC), Radboud University Medical Center, Nijmegen, the Netherlands
| | - Baziel G M van Engelen
- Department of Neurology, Donders Institute for Brain, Cognition and Behavior, Radboud University Medical Center, Nijmegen, the Netherlands
| | - Andrea Aliverti
- Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, Milan, Italy
| | - Jonne Doorduin
- Department of Neurology, Donders Institute for Brain, Cognition and Behavior, Radboud University Medical Center, Nijmegen, the Netherlands
| |
Collapse
|
14
|
Point-of-care lung and diaphragm ultrasound in a patient with spinal muscular atrophy with respiratory distress type 1. J Ultrasound 2021; 25:395-398. [PMID: 33847972 DOI: 10.1007/s40477-021-00584-w] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2021] [Accepted: 04/02/2021] [Indexed: 01/19/2023] Open
Abstract
Spinal muscular atrophy with respiratory distress type 1 (SMARD1, OMIM #604,320), is a rare autosomal recessive disease resulting from degeneration of motor neurons in the anterior horns, which leads irreversible diaphragmatic palsy and progressive distal symmetrical muscular weakness. Respiratory distress is the main symptom and is severe, rapidly progressive, and frequently requiring invasive ventilation. Despite diaphragm being one of the target organ of the disease, no specific study has been done using ultrasound.We report diaphragm and lung ultrasound findings of a 13-month-old girl affected by SMARD1 (homozygosis c.1540G > A mutation in IGHMPB2 gene) with respiratory failure requiring permanent mechanical ventilation since birth and we discuss the role of diaphragmatic and lung ultrasound in this category of patients and its clinical implications.
Collapse
|
15
|
Alonso-Ojembarrena A, Ruiz-González E, Estepa-Pedregosa L, Armenteros-López AI, Segado-Arenas A, Lubián-López SP. Reproducibility and reference values of diaphragmatic shortening fraction for term and premature infants. Pediatr Pulmonol 2020; 55:1963-1968. [PMID: 32458563 DOI: 10.1002/ppul.24866] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/01/2020] [Accepted: 05/22/2020] [Indexed: 02/03/2023]
Abstract
BACKGROUND New ultrasound measurements to diagnose diaphragmatic dysfunction, including diaphragmatic shortening fraction (DSF), have been studied in adults and children, but there are no data on reference values for neonates. OBJECTIVE To describe DSF reference values for term neonate (TN) and preterm neonate (PTN), and to calculate its reproducibility. METHODS We included asymptomatic TN and PTN during their first 24 hours of life. We measured DSF at the zone of apposition in both hemithoraces. Reproducibility of image acquisition, including inter- and intra-rater agreement of the measurements were calculated among an experienced and a novel operator (after completion of a 1-day course on lung ultrasound [LU] and performance of 10 diaphragm ultrasounds [DUs] under supervision), and a more-trained examiner (completion of a 1-day course on LU and performance of 60 DUs under supervision). RESULTS Two groups of 33 TN and 33 PTN were studied. Median DSF values did not differ between the groups, although diaphragm thickness was higher in the TN group. Intra-observer reproducibility: the intraclass correlation coefficient (ICC) was 0.95 (95% confidence interval [95% CI] 0.86-0.98). Interobserver reproducibility with novel operator had an ICC of 0.42 (95% CI -0.74 to 0.81), and with a more experienced operator improved to 0.76 (95% CI 0.27-0.92). Both intra- and interobserver agreement were high. CONCLUSIONS Asymptomatic TN and PTN have similar DSF values in the first 24 hours of life. The intra- and interobserver agreement is high. Reproducibility is acceptable, but intensive training is necessary to perform adequate DU.
Collapse
Affiliation(s)
| | | | | | | | | | - Simón Pedro Lubián-López
- Neonatal Intensive Care Unit, Puerta del Mar University Hospital, Cádiz, Spain.,Department of Maternal and Child Health and Radiology, School of Medicine, University of Cádiz, Cádiz, Spain
| |
Collapse
|