Kooij S, Chojnacka A, Bonn D, Corthals GL, van Rijn CJM. Electroless Ionization Mass Spectrometry Using a Compact Electrokinetic Ionization Source. Anal Chem 2024; 96:10978-10985. [PMID: 38917274 PMCID: PMC11238159 DOI: 10.1021/acs.analchem.4c01403] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2024] [Revised: 06/10/2024] [Accepted: 06/11/2024] [Indexed: 06/27/2024]
Abstract
We introduce a new ionization technique for compact, portable mass spectrometers. It consists of a syringe with sample liquid capped by a self-ionizing spray nozzle containing a microfabricated nozzle chip. Interaction of the sample liquid with the nozzle wall results in electrical charging without the need for electronics. Elaborate cleaning procedures are redundant when disposable syringes and mass-fabricated spray nozzles are used. This self-named electroless spray ionization (ELI) technique shows comparable performance to conventional ionization techniques. In contrast to commonly used electrospray ionization, ELI exhibits excellent ionization efficiency for low-conductive solutions such as water or acetonitrile. Due to its compact size and the absence of high-voltage electronics, it can also be readily integrated in other ionization sources. Besides reviewing the main properties of ELI, we showcase the technique's potential for two on-site, ambient mass spectroscopy applications: perfume fingerprinting and fast screening of fungicides on citrus fruits.
Collapse
Affiliation(s)
- Stefan Kooij
- Van
der Waals-Zeeman Institute, University of
Amsterdam, Science Park 904, 1098 XH Amsterdam, The Netherlands
| | - Aleksandra Chojnacka
- Van
’t Hoff Institute for Molecular Sciences, University of Amsterdam, Science Park 904, 1098 XH Amsterdam, The Netherlands
| | - Daniel Bonn
- Van
der Waals-Zeeman Institute, University of
Amsterdam, Science Park 904, 1098 XH Amsterdam, The Netherlands
| | - Garry L. Corthals
- Van
’t Hoff Institute for Molecular Sciences, University of Amsterdam, Science Park 904, 1098 XH Amsterdam, The Netherlands
| | - Cees J. M. van Rijn
- Van
der Waals-Zeeman Institute, University of
Amsterdam, Science Park 904, 1098 XH Amsterdam, The Netherlands
| |
Collapse
|
2
|
Trimpin S, Inutan ED, Pagnotti VS, Karki S, Marshall DD, Hoang K, Wang B, Lietz CB, Richards AL, Yenchick FS, Lee C, Lu IC, Fenner M, Madarshahian S, Saylor S, Chubatyi ND, Zimmerman T, Moreno-Pedraza A, Wang T, Adeniji-Adele A, Meher AK, Madagedara H, Owczarzak Z, Musavi A, Hendrickson TL, Peacock PM, Tomsho JW, Larsen BS, Prokai L, Shulaev V, Pophristic M, McEwen CN. Direct sub-atmospheric pressure ionization mass spectrometry: Evaporation/sublimation-driven ionization is amazing, fundamentally, and practically. JOURNAL OF MASS SPECTROMETRY : JMS 2024; 59:e5018. [PMID: 38736378 DOI: 10.1002/jms.5018] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/18/2023] [Revised: 12/08/2023] [Accepted: 03/04/2024] [Indexed: 05/14/2024]
Abstract
This paper covers direct sub-atmospheric pressure ionization mass spectrometry (MS). The discovery, applications, and mechanistic aspects of novel ionization processes for use in MS that are not based on the high-energy input from voltage, laser, and/or high temperature but on sublimation/evaporation within a region linking a higher to lower pressure and modulated by heat and collisions, are discussed, including how this new reality has guided a series of discoveries, instrument developments, and commercialization. A research focus, inter alia, is on how best to understand, improve, and use these novel ionization processes, which convert volatile and nonvolatile compounds from solids (sublimation) or liquids (evaporation) into gas-phase ions for analysis by MS providing reproducible, accurate, sensitive, and prompt results. Our perception on how these unprecedented versus traditional ionization processes/methods relate to each other, how they can be made to coexist on the same mass spectrometer, and an outlook on new and expanded applications (e.g., clinical, portable, fast, safe, and autonomous) is presented, and is based on ST's Opening lecture presentation at the Nordic Mass spectrometry Conference, Geilo, Norway, January 2023. Focus will be on matrix-assisted ionization (MAI) and solvent-assisted ionization (SAI) MS covering the period from 2010 to 2023; a potential paradigm shift in the making.
Collapse
Affiliation(s)
- Sarah Trimpin
- Department of Chemistry, Wayne State University, Detroit, Michigan, USA
- MSTM, LLC, Newark, Delaware, USA
| | - Ellen D Inutan
- Department of Chemistry, Wayne State University, Detroit, Michigan, USA
- MSTM, LLC, Newark, Delaware, USA
- Mindanao State University-Iligan Institute of Technology, Iligan City, Philippines
| | - Vincent S Pagnotti
- Department of Chemistry & Biochemistry, Saint Joseph's University, Philadelphia, Pennsylvania, USA
| | - Santosh Karki
- Department of Chemistry, Wayne State University, Detroit, Michigan, USA
- MSTM, LLC, Newark, Delaware, USA
| | - Darrell D Marshall
- Department of Chemistry, Wayne State University, Detroit, Michigan, USA
- MSTM, LLC, Newark, Delaware, USA
| | - Khoa Hoang
- MSTM, LLC, Newark, Delaware, USA
- Department of Chemistry & Biochemistry, Saint Joseph's University, Philadelphia, Pennsylvania, USA
| | - Beixi Wang
- Department of Chemistry, Wayne State University, Detroit, Michigan, USA
| | | | - Alicia L Richards
- Department of Chemistry, Wayne State University, Detroit, Michigan, USA
| | - Frank S Yenchick
- Department of Chemistry, Wayne State University, Detroit, Michigan, USA
| | - Chuping Lee
- Department of Chemistry, Wayne State University, Detroit, Michigan, USA
| | - I-Chung Lu
- Department of Chemistry, Wayne State University, Detroit, Michigan, USA
- Department of Chemistry, National Chung Hsing University, Taichung, Taiwan
| | - Madeleine Fenner
- Department of Chemistry & Biochemistry, Saint Joseph's University, Philadelphia, Pennsylvania, USA
| | - Sara Madarshahian
- Department of Chemistry & Biochemistry, Saint Joseph's University, Philadelphia, Pennsylvania, USA
| | - Sarah Saylor
- Department of Chemistry & Biochemistry, Saint Joseph's University, Philadelphia, Pennsylvania, USA
| | - Nicolas D Chubatyi
- Department of Chemistry & Biochemistry, Saint Joseph's University, Philadelphia, Pennsylvania, USA
| | - Teresa Zimmerman
- Department of Chemistry, Wayne State University, Detroit, Michigan, USA
| | | | - Tongwen Wang
- Department of Chemistry & Biochemistry, Saint Joseph's University, Philadelphia, Pennsylvania, USA
| | - Adetoun Adeniji-Adele
- Department of Chemistry & Biochemistry, Saint Joseph's University, Philadelphia, Pennsylvania, USA
| | - Anil K Meher
- Department of Chemistry, Wayne State University, Detroit, Michigan, USA
- MSTM, LLC, Newark, Delaware, USA
| | - Hasini Madagedara
- Department of Chemistry, Wayne State University, Detroit, Michigan, USA
| | - Zachary Owczarzak
- Department of Chemistry, Wayne State University, Detroit, Michigan, USA
| | - Ahmed Musavi
- Department of Chemistry, Wayne State University, Detroit, Michigan, USA
| | | | | | - John W Tomsho
- Department of Chemistry & Biochemistry, Saint Joseph's University, Philadelphia, Pennsylvania, USA
| | | | - Laszlo Prokai
- Department of Pharmacology and Neuroscience, The University of North Texas Health Science Center at Forth Worth, Fort Worth, Texas, USA
| | - Vladimir Shulaev
- Department of Biological Sciences, The University of North Texas, Denton, Texas, USA
| | - Milan Pophristic
- MSTM, LLC, Newark, Delaware, USA
- Department of Chemistry & Biochemistry, Saint Joseph's University, Philadelphia, Pennsylvania, USA
| | - Charles N McEwen
- MSTM, LLC, Newark, Delaware, USA
- Department of Chemistry & Biochemistry, Saint Joseph's University, Philadelphia, Pennsylvania, USA
| |
Collapse
|
3
|
Trimpin S, Inutan E, Coffinberger H, Hoang K, Yenchick F, Wager-Miller J, Pophristic M, Mackie K, McEwen CN. Instrumentation development, improvement, simplification, and miniaturization: The multifunctional plate source for use in mass spectrometry. EUROPEAN JOURNAL OF MASS SPECTROMETRY (CHICHESTER, ENGLAND) 2023; 29:276-291. [PMID: 37999746 DOI: 10.1177/14690667231211486] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/25/2023]
Abstract
In remembrance of Prof. Dr Przybylski, we are presenting a vision towards his beloved mass spectrometry (MS) and its far-reaching promises outside of the academic laboratory. Sub-atmospheric pressure (AP) ionization MS is well positioned to make a step-change in direct ionization, a concept that allows sublimation/evaporation ionization and mass analyses of volatile and nonvolatile molecules from clean or dirty samples, directly, accurately, sensitively, and in a straightforward manner that has the potential to expand the field of MS into unchartered application areas. Contrary to ambient ionization MS, ionization commences in the sub-AP region of the mass spectrometer, important for practical and safety reasons, and offers inter alia, simplicity, speed, sensitivity, and robustness directly from real-world samples without cleanup. The plate source concept, presented here, provides an easy to use, rapid, and direct sample introduction from AP into the sub-AP of a mass spectrometer. Utilizing sub-AP ionization MS based on the plate source concept, small to large molecules from various environments that would be deemed too dirty for some direct MS methods are demonstrated. The new source concept can be expanded to include multiple ionization methods using the same plate source "front end" without the need to vent the mass spectrometer between the different methods, thus allowing ionization of more compounds on the same mass spectrometer for which any one ionization method may be insufficient. Examples such as fentanyl, gamma-hydroxybutyric acid, clozapine, 1-propionyllysergic acid, hydrocodone angiotensin I and II, myoglobin, and carbonic anhydrase are included.
Collapse
Affiliation(s)
- Sarah Trimpin
- Wayne State University, Detroit, MI, USA
- Research and Development, MSTM, LLC, Philadelphia, PA, USA
| | - Ellen Inutan
- Department of Chemistry, Mindanao State University-Illigan Institute of Technology, Illigan City, Philippines
| | - Hope Coffinberger
- Research and Development, MSTM, LLC, Philadelphia, PA, USA
- Department of Chemistry & Biochemistry, Saint Joseph's University, Philadelphia, PA, USA
| | - Khoa Hoang
- Research and Development, MSTM, LLC, Philadelphia, PA, USA
- Department of Chemistry & Biochemistry, Saint Joseph's University, Philadelphia, PA, USA
| | | | - James Wager-Miller
- Psychological and Brain Sciences Campus, Indiana University, Bloomington, IN, USA
| | - Milan Pophristic
- Research and Development, MSTM, LLC, Philadelphia, PA, USA
- Department of Chemistry & Biochemistry, Saint Joseph's University, Philadelphia, PA, USA
| | - Ken Mackie
- Psychological and Brain Sciences Campus, Indiana University, Bloomington, IN, USA
| | - Charles N McEwen
- Research and Development, MSTM, LLC, Philadelphia, PA, USA
- Department of Chemistry & Biochemistry, Saint Joseph's University, Philadelphia, PA, USA
| |
Collapse
|
4
|
Trimpin S. A tutorial: Laserspray ionization and related laser-based ionization methods for use in mass spectrometry. MASS SPECTROMETRY REVIEWS 2023; 42:2234-2267. [PMID: 37462443 DOI: 10.1002/mas.21762] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/04/2021] [Revised: 09/30/2021] [Accepted: 11/15/2021] [Indexed: 08/09/2023]
Abstract
This Tutorial is to provide a summary of parameters useful for successful outcomes of laserspray ionization (LSI) and related methods that employ a laser to ablate a matrix:analyte sample to produce highly charged ions. In these methods the purpose of the laser is to transfer matrix-analyte clusters into the gas phase. Ions are hypothesized to be produced by a thermal process where emitted matrix:analyte gas-phase particles/clusters are charged and loss of matrix from the charged particles leads to release of the analyte ions into the gas phase. The thermal energy responsible for the charge-separation process is relatively low and not necessarily supplied by the laser; a heated inlet tube linking atmospheric pressure with the first vacuum stage of a mass spectrometer is sufficient. The inlet becomes the "ion source", and inter alia, pressure, temperature, and the matrix, which can be a solid, liquid, or combinations, become critical parameters. Injecting matrix:analyte into a heated inlet tube using laser ablation, a shockwave, or simply tapping, all produce the similar mass spectra. Applications are provided that showcase new opportunities in the field of mass spectrometry.
Collapse
Affiliation(s)
- Sarah Trimpin
- Department of Chemistry, Wayne State University, Detroit, Michigan, USA
- MSTM, LLC, Newark, Delaware, USA
| |
Collapse
|
5
|
Harvey DJ. Analysis of carbohydrates and glycoconjugates by matrix-assisted laser desorption/ionization mass spectrometry: An update for 2019-2020. MASS SPECTROMETRY REVIEWS 2022:e21806. [PMID: 36468275 DOI: 10.1002/mas.21806] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/17/2023]
Abstract
This review is the tenth update of the original article published in 1999 on the application of matrix-assisted laser desorption/ionization (MALDI) mass spectrometry to the analysis of carbohydrates and glycoconjugates and brings coverage of the literature to the end of 2020. Also included are papers that describe methods appropriate to analysis by MALDI, such as sample preparation techniques, even though the ionization method is not MALDI. The review is basically divided into three sections: (1) general aspects such as theory of the MALDI process, matrices, derivatization, MALDI imaging, fragmentation, quantification and the use of arrays. (2) Applications to various structural types such as oligo- and polysaccharides, glycoproteins, glycolipids, glycosides and biopharmaceuticals, and (3) other areas such as medicine, industrial processes and glycan synthesis where MALDI is extensively used. Much of the material relating to applications is presented in tabular form. The reported work shows increasing use of incorporation of new techniques such as ion mobility and the enormous impact that MALDI imaging is having. MALDI, although invented nearly 40 years ago is still an ideal technique for carbohydrate analysis and advancements in the technique and range of applications show little sign of diminishing.
Collapse
Affiliation(s)
- David J Harvey
- Nuffield Department of Medicine, Target Discovery Institute, University of Oxford, Oxford, UK
- Department of Chemistry, University of Oxford, Oxford, Oxfordshire, United Kingdom
| |
Collapse
|
6
|
Owen RN, Bajic S, Kelly SL, Morris MR, Brenton AG. Glow flow ionization mass spectrometry of small molecules. A comparison of a glow flow ionization source ('GlowFlow') with electrospray ionization and atmospheric pressure chemical ionization. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2022; 36:e9327. [PMID: 35610187 PMCID: PMC9285393 DOI: 10.1002/rcm.9327] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/14/2022] [Revised: 05/21/2022] [Accepted: 05/21/2022] [Indexed: 06/15/2023]
Abstract
RATIONALE Ionization by atmospheric pressure gas discharge has been employed for a long time in mass spectrometry. Inductively coupled plasma mass spectrometry is an exemplar, and widely used for elemental analysis. The technique has less uptake in organic mass spectrometry. We describe a simple source design that can be readily implemented in most atmospheric pressure ionization (API) systems and compare its performance with that of electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI). METHODS An in-house designed helium gas discharge source (referred to as 'GlowFlow') was used on a Xevo G2-S time-of-flight mass spectrometer. The GlowFlow source was transferred to a compatible Xevo TQ-S triple-quadrupole mass spectrometer using an ultrahigh-performance liquid chromatograph inlet. Its performance was compared to that of Waters ESI and APCI sources. RESULTS Preliminary results of GlowFlow on the Swansea instrument are presented to establish context and include analysis of low-molecular-mass polymers, benzoic acid and cinnamic acid. Comparison of performance on the Xevo TQ-S triple-quadrupole mass spectrometer involved three test mixtures. The method limits of detection (six-mix) for positive-ion GlowFlow source were between 0.03 and 10.00 pg with good linear response over two to four orders of magnitude and values of R2 > 0.98. The GlowFlow ionization source provided a signal intensity that was an order of magnitude greater than that of ESI for an atmospheric pressure gas chromatography standard mix and ionized several compounds that ESI could not. CONCLUSIONS The current GlowFlow design is relatively simple to retrofit to most API systems due to its small size. The sensitivity of the GlowFlow design is typically an order of magnitude less than that of ESI in positive-ion mode, but similar in sensitivity in negative-ion mode and comparable to that of APCI.
Collapse
Affiliation(s)
- Rhodri N. Owen
- Institute of Life Science, Faculty of Medicine, Health and Life ScienceSwansea UniversitySwanseaUK
| | | | - Steven L. Kelly
- Institute of Life Science, Faculty of Medicine, Health and Life ScienceSwansea UniversitySwanseaUK
| | | | - A. Gareth Brenton
- Institute of Life Science, Faculty of Medicine, Health and Life ScienceSwansea UniversitySwanseaUK
| |
Collapse
|
7
|
Pursell ME, Sharif D, DeBastiani A, Li C, Majuta S, Li P, Valentine SJ. Development of cVSSI-APCI for the Improvement of Ion Suppression and Matrix Effects in Complex Mixtures. Anal Chem 2022; 94:9226-9233. [PMID: 35729103 PMCID: PMC9260805 DOI: 10.1021/acs.analchem.1c05136] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
The new ionization technique termed vibrating sharp-edge spray ionization (cVSSI) has been coupled with corona discharge to investigate atmospheric pressure chemical ionization (APCI) capabilities. The optimized source was evaluated for its ability to enhance ion signal intensity, overcome matrix effects, and limit ion suppression. The results have been compared with state-of-the-art ESI source performance as well as a new APCI-like source. In methanol, the ion signal intensity increased 10-fold and >10-fold for cocaine and the suppressed analytes, respectively. The ability to overcome ion suppression was improved from 2-fold to 16-fold for theophylline and vitamin D2, respectively. For aqueous samples, ion signal levels increased by two orders of magnitude for all analytes. In both solvent systems, the signal-to-noise ratios also increased for all suppressed analytes. One example of the characterization of low-ionizing (by ESI or cVSSI alone) species in the presence of high-ionizing species by direct analysis from a cotton swab is presented. The work is discussed with respect to the advantages of cVSSI-APCI for direct, in situ, and field analyses.
Collapse
Affiliation(s)
- Madison E. Pursell
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, WV 26506
| | - Daud Sharif
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, WV 26506
| | - Anthony DeBastiani
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, WV 26506
| | - Chong Li
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, WV 26506
| | - Sandra Majuta
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, WV 26506
| | - Peng Li
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, WV 26506
| | - Stephen J. Valentine
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, WV 26506
| |
Collapse
|
8
|
Xu C, Ruan H, Wang W, Li H. Triboionization in Discontinuous Atmospheric Pressure Inlet for a Miniature Ion Trap Mass Spectrometer. Anal Chem 2021; 93:15897-15904. [PMID: 34817157 DOI: 10.1021/acs.analchem.1c02611] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
Discontinuous atmospheric pressure interface (DAPI) consisting of a pinch valve, a silicone tube, and two metal capillaries has been widely used in miniature mass spectrometry. It is interesting that clear ion signals could be observed even when the extra ionization source was turned off. In-depth analysis suggested that this new ionization phenomenon known as triboionization is based on the surface friction on the inner surface of the silicone tube during the on/off of the pinch valve. In this study, triboionization in the DAPI of a miniature ion trap mass spectrometer was investigated. It was discovered that the signal intensity depended greatly on the material and the roughness of the silicone tube used in the DAPI. By rubbing the inner surface of the silicone tube, for example, the signal intensity can increase by nearly 20 times. Two connected pinch valves were developed to study the effects of the discharge pressure, the number, and the frequency of on/off of the pinch valve on triboionization, which were verified to have a large impact on the product ions. In addition, the humidity of the inner surface of the silicone tube impacted the signal intensity of product ions and the mass spectrum patterns, where the product ions were typically protonated ions. As the humidity increases, the signal intensity of analytes with high proton affinity increases accordingly. This triboionization source, which does not require heat, light, radiation, auxiliary gas, or solution, has been preliminarily proved to have potential for surface detection after continuous enrichment.
Collapse
Affiliation(s)
- Chuting Xu
- Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences (CAS), 457 Zhongshan Road, Dalian 116023, People's Republic of China.,University of Chinese Academy of Sciences, 19 Yuquan Road, Beijing 100049, People's Republic of China.,Dalian Key Laboratory for Online Analytical Instrumentation, 457 Zhongshan Road, Dalian 116023, People's Republic of China
| | - Huiwen Ruan
- Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences (CAS), 457 Zhongshan Road, Dalian 116023, People's Republic of China.,University of Chinese Academy of Sciences, 19 Yuquan Road, Beijing 100049, People's Republic of China.,Dalian Key Laboratory for Online Analytical Instrumentation, 457 Zhongshan Road, Dalian 116023, People's Republic of China
| | - Weiguo Wang
- Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences (CAS), 457 Zhongshan Road, Dalian 116023, People's Republic of China.,Dalian Key Laboratory for Online Analytical Instrumentation, 457 Zhongshan Road, Dalian 116023, People's Republic of China
| | - Haiyang Li
- Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences (CAS), 457 Zhongshan Road, Dalian 116023, People's Republic of China.,Dalian Key Laboratory for Online Analytical Instrumentation, 457 Zhongshan Road, Dalian 116023, People's Republic of China
| |
Collapse
|
9
|
Halvorsen TG, Levernæs MCS, Rosting C. Matrix-Assisted Ionization and Tandem Mass Spectrometry Capabilities in Protein Biomarker Characterization-An Initial Study Using the Small Cell Lung Cancer Biomarker Progastrin Releasing Peptide as a Model Compound. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2021; 32:611-614. [PMID: 33382608 DOI: 10.1021/jasms.0c00336] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
This initial study evaluates vacuum matrix-assisted ionization (vMAI) mass spectrometry (MS) for identification and determination of tryptic peptides from the biomarker protein progastrin releasing peptide (ProGRP). Similar peptides and charge states were observed as in liquid chromatography (LC) electrospray ionization (ESI) MS. The prolonged ion duration in vMAI with similar charge states as in ESI was advantageous for determining the MS/MS fragmentation conditions compared to MAI. It is assumed that the vacuum ionization conditions lower the detection limits of the experiment. This may be the reason vMAI combined with high resolution MS enabled detection of tryptic peptides from more digested proteins than MAI selected reaction monitoring MS. Additionally, MAI ion mobility spectrometry MS (MAI-IMS-MS) was evaluated for differentiation of intact protein isoforms, successfully enabling differentiation of the isoforms by drift time selection. Examples are both shown for model proteins bovine serum albumin, cytochrome C, and lysozyme and the clinically relevant small cell lung cancer protein biomarker ProGRP, which exists in three isoforms. Coupling with the vacuum ionization conditions using a dedicated vacuum-probe source MAI enables information to be extracted readily as with conventional approaches, just faster.
Collapse
Affiliation(s)
| | | | - Cecilie Rosting
- Department of Pharmacy, University of Oslo, 0371 Oslo, Norway
| |
Collapse
|
10
|
McEwen CN, Inutan ED, Moreno-Pedraza A, Lu IC, Hoang K, Pophristic M, Trimpin S. Sublimation Driven Ionization for Use in Mass Spectrometry: Mechanistic Implications. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2021; 32:114-123. [PMID: 33280376 DOI: 10.1021/jasms.0c00297] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Sublimation has been known at least since the middle ages. This process is frequently taught in schools through the use of phase diagrams. Astonishingly, such a well-known process appears to still harbor secrets. Under conditions in which compound sublimation occurs, gas-phase ions are frequently detected using mass spectrometry. This was exploited in matrix-assisted ionization in vacuum (vMAI) by adding analyte to subliming compounds used as matrices. Good vMAI matrices were those that ionize the added analyte with high sensitivity, but even matrices that fail this test often produce ions of likely matrix impurities suggesting that they may be good matrices for some compound types. We also show that binary matrices may be manipulated to provide desired properties such as fast analyses and improved sensitivity. These results imply that sublimation in some cases is more complicated than just molecules leaving a surface and that understanding the physical force responsible, and how the nonvolatile compound becomes charged, could lead to improved ionization efficiency for mass spectrometry. Here we provide insights into this process and an explanation of why this unexpected phenomenon has not previously been reported.
Collapse
Affiliation(s)
- Charles N McEwen
- University of the Sciences, Philadelphia, Pennsylvania 19104, United States
- MSTM, LLC, Newark, Delaware 19711, United States
| | - Ellen D Inutan
- MSTM, LLC, Newark, Delaware 19711, United States
- Mindanao State University Iligan Institute of Technology, Iligan City 9200, Philippines
| | | | - I-Chung Lu
- National Chung Hsing University, Taichung City, Taiwan 402
| | - Khoa Hoang
- MSTM, LLC, Newark, Delaware 19711, United States
| | | | - Sarah Trimpin
- MSTM, LLC, Newark, Delaware 19711, United States
- Wayne State University, Detroit, Michigan 48202, United States
| |
Collapse
|
11
|
Austin CA, Inutan ED, Bohrer BC, Li J, Fischer JL, Wijerathne K, Foley CD, Lietz CB, Woodall DW, Imperial LF, Clemmer DE, Trimpin S, Larsen BS. Resolving Isomers of Star-Branched Poly(Ethylene Glycols) by IMS-MS Using Multiply Charged Ions. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2021; 32:21-32. [PMID: 32510213 DOI: 10.1021/jasms.0c00045] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Ion mobility spectrometry (IMS) mass spectrometry (MS) centers on the ability to separate gaseous structures by size, charge, shape, and followed by mass-to-charge (m/z). For oligomeric structures, improved separation is hypothesized to be related to the ability to extend structures through repulsive forces between cations electrostatically bonded to the oligomers. Here we show the ability to separate differently branched multiply charged ions of star-branched poly(ethylene glycol) oligomers (up to 2000 Da) regardless of whether formed by electrospray ionization (ESI) charged solution droplets or from charged solid particles produced directly from a surface by matrix-assisted ionization. Detailed structural characterization of isomers of the star-branched compositions was first established using a home-built high-resolution ESI IMS-MS instrument. The doubly charged ions have well-resolved drift times, achieving separation of isomers and also allowing differentiation of star-branched versus linear oligomers. An IMS-MS "snapshot" approach allows visualization of architectural dispersity and (im)purity of samples in a straightforward manner. Analyses capabilities are shown for different cations and ionization methods using commercially available traveling wave IMS-MS instruments. Analyses directly from surfaces using the new ionization processes are, because of the multiply charging, not only associated with the benefits of improved gas-phase separations, relative to that of ions produced by matrix-assisted laser desorption/ionization, but also provide the potential for spatially resolved measurements relative to ESI and other ionization methods.
Collapse
Affiliation(s)
- Calvin A Austin
- Department of Chemistry, Wayne State University, Detroit, Michigan 48202, United States
| | - Ellen D Inutan
- Department of Chemistry, Wayne State University, Detroit, Michigan 48202, United States
| | - Brian C Bohrer
- Department of Chemistry, Indiana University, Bloomington, Indiana 47405, United States
| | - Jing Li
- Department of Chemistry, Wayne State University, Detroit, Michigan 48202, United States
| | - Joshua L Fischer
- Department of Chemistry, Wayne State University, Detroit, Michigan 48202, United States
| | - Kanchana Wijerathne
- Department of Chemistry, Wayne State University, Detroit, Michigan 48202, United States
| | - Casey D Foley
- Department of Chemistry, Wayne State University, Detroit, Michigan 48202, United States
| | - Christopher B Lietz
- Department of Chemistry, Wayne State University, Detroit, Michigan 48202, United States
| | - Daniel W Woodall
- Department of Chemistry, Wayne State University, Detroit, Michigan 48202, United States
| | - Lorelie F Imperial
- Department of Chemistry, Wayne State University, Detroit, Michigan 48202, United States
| | - David E Clemmer
- Department of Chemistry, Indiana University, Bloomington, Indiana 47405, United States
| | - Sarah Trimpin
- Department of Chemistry, Wayne State University, Detroit, Michigan 48202, United States
| | - Barbara S Larsen
- DuPont, Nutrition & Biosciences, Wilmington, Delaware 19808, United States
| |
Collapse
|
12
|
Hoang K, Trimpin S, McEwen CN, Pophristic M. A Combination MAI and MALDI Vacuum Source Operational from Atmospheric Pressure for Fast, Robust, and Sensitive Analyses. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2021; 32:124-132. [PMID: 33270447 DOI: 10.1021/jasms.0c00298] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Previously, vacuum matrix-assisted ionization (vMAI) was employed with matrix/analyte sample introduction into the vacuum of a mass spectrometer on a probe sample introduction device. Low attomole detection was achieved, while no carryover was observed even for concentrated samples. Here, we report a new vacuum ionization source designed to duplicate the sensitivity and robustness of probe device while providing fast multisample introduction to vacuum and rapid sequential ionization. Exposure of a sample to the vacuum of the mass spectrometer provides spontaneous ionization of volatile as well as nonvolatile analytes without the need for external energy input. However, the novel source design described herein, in addition to vMAI, can employ a laser to obtain vacuum matrix-assisted laser desorption/ionization (vMALDI). In particular, ionization by vMAI or vMALDI is achieved by using the appropriate matrix. Switching between ionization modes is accomplished in a few seconds. We present results demonstrating the utility of the two ionization methods in combination to improve the molecular analyses of sample composition. In both ionization modes, multiple samples can be sequentially and rapidly acquired to increase throughput in MS. With the prototype source, samples were acquired in as little as 1 s per sample. Exchanging multisample plates can be accomplished in as little as 2 s, suggesting low-cost high-throughput automation when properly developed.
Collapse
Affiliation(s)
- Khoa Hoang
- MS, LLC, Hockessin, Delaware 19707, United States
| | - Sarah Trimpin
- MS, LLC, Hockessin, Delaware 19707, United States
- Wayne State University, Detroit, Michigan 48202, United States
| | - Charles N McEwen
- MS, LLC, Hockessin, Delaware 19707, United States
- University of the Sciences, Philadelphia, Pennsylvania 19104, United States
| | | |
Collapse
|
13
|
Jayasundara K, Li C, DeBastiani A, Sharif D, Li P, Valentine SJ. Physicochemical Property Correlations with Ionization Efficiency in Capillary Vibrating Sharp-Edge Spray Ionization (cVSSI). JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2021; 32:84-94. [PMID: 32856909 PMCID: PMC8130659 DOI: 10.1021/jasms.0c00100] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
The relative contributions to ionization efficiency by three molecular chemical properties have been examined for field-free and field-enabled capillary vibrating sharp-edge spray ionization (cVSSI) using mass spectrometry (MS) analysis. Ion intensities have been recorded for model compounds under each operational ionization mode as well as for aqueous and nonaqueous (methanol) solvent systems. Multiple regression analysis suggests that for field-free cVSSI, ion intensity is mostly associated with the log of the base dissociation constant (pKb) and proton affinity (PA) for both aqueous and methanol solutions. Comparatively, for field-enabled cVSSI using aqueous solutions, the dominant factor correlated with ion intensity is the log of the partition coefficient (log P). To a lesser degree, this is observed for methanol solutions as well. For ESI, pKb is the dominant factor associated with ion signal levels from methanol and aqueous solutions. These results are supported by studies conducted on two different mass spectrometers employing different cVSSI emitter tips. The relationship of ion intensity and pKb in ESI is supported by multiple studies; however, the shift to other chemical properties with the addition of cVSSI suggests the possibility that a different (or combinations of) ionization mechanism(s) may be operative for these ionization modes. These results are briefly considered in light of the different ESI mechanisms.
Collapse
Affiliation(s)
| | | | | | | | - Peng Li
- To whom correspondence should be addressed: , and .
| | | |
Collapse
|
14
|
Mannion DR, Mannion JM, Kuhne WW, Wellons MS. Matrix-Assisted Ionization of Molecular Uranium Species. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2021; 32:8-13. [PMID: 33253565 DOI: 10.1021/jasms.0c00305] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Matrix-assisted ionization (MAI) demonstrates high sensitivity for a variety of organic compounds; however, few studies have reported the application of MAI for the detection and characterization of inorganic analytes. Trace-level uranium analysis is important in the realms of nuclear forensics, nuclear safeguards, and environmental monitoring. Traditional mass spectrometry methods employed in these fields require combinations of extensive laboratory chemistry sample preparation and destructive ionization methods. There has been recent interest in exploring ambient mass spectrometry methods that enable timely sample analysis and higher sensitivity than what is attainable by field-portable radiation detectors. Rapid characterization of uranium at nanogram levels is demonstrated in this study using MAI techniques. Mass spectra were collected on an atmospheric pressure mass spectrometer for solutions of uranyl nitrate, uranyl chloride, uranyl acetate, and uranyl oxalate utilizing 3-nibrobenzonitrile as the ionization matrix. The uranyl complexes investigated were detectable, and the chemical speciation was preserved. Sample analysis was accomplished in a matter of seconds, and limits of detection of 5 ng of uranyl nitrate, 10 ng of uranyl oxalate, 100 ng of uranyl chloride, and 200 ng of uranyl acetate were achieved. The observed gas-phase speciation was similar to negative-ion electrospray ionization of uranyl compounds with notable differences. Six matrix-derived ions were detected in all negative-ion mass spectra, and some of these ions formed adducts with the uranyl analyte. Subsequent analysis of the matrix suggests that these molecules are not matrix contaminants and are instead created during the ionization process.
Collapse
Affiliation(s)
- Danielle R Mannion
- Savannah River National Laboratory, Aiken, South Carolina 29803, United States
| | - Joseph M Mannion
- Savannah River National Laboratory, Aiken, South Carolina 29803, United States
| | - Wendy W Kuhne
- Savannah River National Laboratory, Aiken, South Carolina 29803, United States
| | - Matthew S Wellons
- Savannah River National Laboratory, Aiken, South Carolina 29803, United States
| |
Collapse
|
15
|
Trimpin S, Marshall DD, Karki S, Madarshahian S, Hoang K, Meher AK, Pophristic M, Richards AL, Lietz CB, Fischer JL, Elia EA, Wang B, Pagnotti VS, Lutomski CA, El-Baba TJ, Lu IC, Wager-Miller J, Mackie K, McEwen CN, Inutan ED. An overview of biological applications and fundamentals of new inlet and vacuum ionization technologies. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2021; 35 Suppl 1:e8829. [PMID: 32402102 DOI: 10.1002/rcm.8829] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/24/2020] [Revised: 05/01/2020] [Accepted: 05/10/2020] [Indexed: 06/11/2023]
Abstract
RATIONALE The developments of new ionization technologies based on processes previously unknown to mass spectrometry (MS) have gained significant momentum. Herein we address the importance of understanding these unique ionization processes, demonstrate the new capabilities currently unmet by other methods, and outline their considerable analytical potential. METHODS The inlet and vacuum ionization methods of solvent-assisted ionization (SAI), matrix-assisted ionization (MAI), and laserspray ionization can be used with commercial and dedicated ion sources producing ions from atmospheric or vacuum conditions for analyses of a variety of materials including drugs, lipids, and proteins introduced from well plates, pipet tips and plate surfaces with and without a laser using solid or solvent matrices. Mass spectrometers from various vendors are employed. RESULTS Results are presented highlighting strengths relative to ionization methods of electrospray ionization (ESI) and matrix-assisted laser desorption/ionization. We demonstrate the utility of multi-ionization platforms encompassing MAI, SAI, and ESI and enabling detection of what otherwise is missed, especially when directly analyzing mixtures. Unmatched robustness is achieved with dedicated vacuum MAI sources with mechanical introduction of the sample to the sub-atmospheric pressure (vacuum MAI). Simplicity and use of a wide array of matrices are attained using a conduit (inlet ionization), preferably heated, with sample introduction from atmospheric pressure. Tissue, whole blood, urine (including mouse, chicken, and human origin), bacteria strains and chemical on-probe reactions are analyzed directly and, especially in the case of vacuum ionization, without concern of carryover or instrument contamination. CONCLUSIONS Examples are provided highlighting the exceptional analytical capabilities associated with the novel ionization processes in MS that reduce operational complexity while increasing speed and robustness, achieving mass spectra with low background for improved sensitivity, suggesting the potential of this simple ionization technology to drive MS into areas currently underserved, such as clinical and medical applications.
Collapse
Affiliation(s)
- Sarah Trimpin
- Department of Chemistry, Wayne State University, Detroit, MI, 48202, USA
- MS™, LLC, Newark, DE, 19711, USA
| | - Darrell D Marshall
- Department of Chemistry, Wayne State University, Detroit, MI, 48202, USA
- MS™, LLC, Newark, DE, 19711, USA
| | - Santosh Karki
- Department of Chemistry, Wayne State University, Detroit, MI, 48202, USA
- MS™, LLC, Newark, DE, 19711, USA
| | | | - Khoa Hoang
- MS™, LLC, Newark, DE, 19711, USA
- University of the Sciences, Philadelphia, PA, 19104, USA
| | - Anil K Meher
- Department of Chemistry, Wayne State University, Detroit, MI, 48202, USA
- MS™, LLC, Newark, DE, 19711, USA
| | - Milan Pophristic
- MS™, LLC, Newark, DE, 19711, USA
- University of the Sciences, Philadelphia, PA, 19104, USA
| | - Alicia L Richards
- Department of Chemistry, Wayne State University, Detroit, MI, 48202, USA
| | | | - Joshua L Fischer
- Department of Chemistry, Wayne State University, Detroit, MI, 48202, USA
| | - Efstathios A Elia
- Department of Chemistry, Wayne State University, Detroit, MI, 48202, USA
| | - Beixi Wang
- Department of Chemistry, Wayne State University, Detroit, MI, 48202, USA
| | | | - Corinne A Lutomski
- Department of Chemistry, Wayne State University, Detroit, MI, 48202, USA
| | - Tarick J El-Baba
- Department of Chemistry, Wayne State University, Detroit, MI, 48202, USA
| | - I-Chung Lu
- Department of Chemistry, Wayne State University, Detroit, MI, 48202, USA
| | - James Wager-Miller
- Gill Center for Biomolecular Science and Department of Psychological and Brain Sciences, Indiana University, Bloomington, IN, 47405, USA
| | - Ken Mackie
- Gill Center for Biomolecular Science and Department of Psychological and Brain Sciences, Indiana University, Bloomington, IN, 47405, USA
| | - Charles N McEwen
- MS™, LLC, Newark, DE, 19711, USA
- University of the Sciences, Philadelphia, PA, 19104, USA
| | - Ellen D Inutan
- Department of Chemistry, Wayne State University, Detroit, MI, 48202, USA
- MS™, LLC, Newark, DE, 19711, USA
- Mindanao State University Iligan Institute of Technology, Iligan City, 9200, Philippines
| |
Collapse
|
16
|
Inutan ED, Jarois DR, Lietz CB, El-Baba TJ, Elia EA, Karki S, Sampat AAS, Foley CD, Clemmer DE, Trimpin S. Comparison of gaseous ubiquitin ion structures obtained from a solid and solution matrix using ion mobility spectrometry/mass spectrometry. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2021; 35 Suppl 1:e8793. [PMID: 32220130 DOI: 10.1002/rcm.8793] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/29/2019] [Revised: 03/24/2020] [Accepted: 03/24/2020] [Indexed: 06/10/2023]
Abstract
RATIONALE Examining surface protein conformations, and especially achieving this with spatial resolution, is an important goal. The recently discovered ionization processes offer spatial-resolution measurements similar to matrix-assisted laser desorption/ionization (MALDI) and produce charge states similar to electrospray ionization (ESI) extending higher-mass protein applications directly from surfaces on high-performance mass spectrometers. Studying a well-interrogated protein by ion mobility spectrometry-mass spectrometry (IMS-MS) to access effects on structures using a solid vs. solvent matrix may provide insights. METHODS Ubiquitin was studied by IMS-MS using new ionization processes with commercial and homebuilt ion sources and instruments (Waters SYNAPT G2(S)) and homebuilt 2 m drift-tube instrument; MS™ sources). Mass-to-charge and drift-time (td )-measurements are compared for ubiquitin ions obtained by inlet and vacuum ionization using laserspray ionization (LSI), matrix- (MAI) and solvent-assisted ionization (SAI), respectively, and compared with those from ESI under conditions that are most comparable. RESULTS Using the same solution conditions with SYNAPT G2(S) instruments, td -distributions of various ubiquitin charge states from MAI, LSI, and SAI are similar to those from ESI using a variety of solvents, matrices, extraction voltages, a laser, and temperature only, showing subtle differences in more compact features within the elongated distribution of structures. However, on a homebuilt drift-tube instrument, within the elongated distribution of structures, both similar and different td -distributions are observed for ubiquitin ions obtained by MAI and ESI. MAI-generated ions are frequently narrower in their td -distributions. CONCLUSIONS Direct comparisons between ESI and the new ionization methods operational directly from surfaces suggest that the protein in its solution structure prior to exposure to the ionization event is either captured (frozen out) at the time of crystallization, or that the protein in the solid matrix is associated with sufficient solvent to maintain the solution structure, or, alternatively, that the observed structures are those related to what occurs in the gas phase with ESI- or MAI-generated ions and not with the solution structures.
Collapse
Affiliation(s)
- Ellen D Inutan
- MSTM, LLC, Newark, DE, USA
- Department of Chemistry, Wayne State University, Detroit, MI, USA
- Mindanao State University-Iligan Institute of Technology, Iligan City, Philippines
| | - Dean R Jarois
- Department of Chemistry, Wayne State University, Detroit, MI, USA
| | | | - Tarick J El-Baba
- Department of Chemistry, Indiana University, Bloomington, IN, USA
| | | | - Santosh Karki
- Department of Chemistry, Wayne State University, Detroit, MI, USA
| | | | - Casey D Foley
- Department of Chemistry, Wayne State University, Detroit, MI, USA
| | - David E Clemmer
- Department of Chemistry, Indiana University, Bloomington, IN, USA
| | - Sarah Trimpin
- MSTM, LLC, Newark, DE, USA
- Department of Chemistry, Wayne State University, Detroit, MI, USA
| |
Collapse
|
17
|
Lee C, Inutan ED, Chen JL, Mukeku MM, Weidner SM, Trimpin S, Ni CK. Toward understanding the ionization mechanism of matrix-assisted ionization using mass spectrometry experiment and theory. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2021; 35 Suppl 1:e8382. [PMID: 30623523 DOI: 10.1002/rcm.8382] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/11/2018] [Accepted: 01/03/2019] [Indexed: 06/09/2023]
Abstract
RATIONALE Matrix-assisted ionization (MAI) mass spectrometry does not require voltages, a laser beam, or added heat to initiate ionization, but it is strongly dependent on the choice of matrix and the vacuum conditions. High charge state distributions of nonvolatile analyte ions produced by MAI suggest that the ionization mechanism may be similar to that of electrospray ionization (ESI), but different from matrix-assisted laser desorption/ionization (MALDI). While significant information is available for MAI using mass spectrometers operating at atmospheric and intermediate pressure, little is known about the mechanism at high vacuum. METHODS Eleven MAI matrices were studied on a high-vacuum time-of-flight (TOF) mass spectrometer using a 266 nm pulsed laser beam under otherwise typical MALDI conditions. Detailed comparisons with the commonly used MALDI matrices and theoretical prediction were made for 3-nitrobenzonitrile (3-NBN), which is the only MAI matrix that works well in high vacuum when irradiated with a laser. RESULTS Screening of MAI matrices with good absorption at 266 nm but with various degrees of volatility and laser energies suggests that volatility and absorption at the laser wavelength may be necessary, but not sufficient, criteria to explain the formation of multiply charged analyte ions. 3-NBN produces intact, highly charged ions of nonvolatile analytes in high-vacuum TOF with the use of a laser, demonstrating that ESI-like ions can be produced in high vacuum. Theoretical calculations and mass spectra suggest that thermally induced proton transfer, which is the major ionization mechanism in MALDI, is not important with the 3-NBN matrix at 266 nm laser wavelength. 3-NBN:analyte crystal morphology is, however, important in ion generation in high vacuum. CONCLUSIONS The 3-NBN MAI matrix produces intact, highly charged ions of nonvolatile compounds in high-vacuum TOF mass spectrometers with the aid of ablation and/or heating by laser irradiation, and shows a different ionization mechanism from that of typical MALDI matrices.
Collapse
Affiliation(s)
- Chuping Lee
- Department of Chemistry, Wayne State University, Detroit, MI, USA
- Institute of Atomic and Molecular Sciences, Academia Sinica, Taipei, Taiwan
| | - Ellen D Inutan
- Department of Chemistry, Mindanao State University-Iligan Institute of Technology, Iligan City, Philippines
| | - Jien Lian Chen
- Institute of Atomic and Molecular Sciences, Academia Sinica, Taipei, Taiwan
| | - Mutanu M Mukeku
- Department of Chemistry, Wayne State University, Detroit, MI, USA
| | - Steffen M Weidner
- Bundesanstalt für Materialforschung und-prüfung, Richard-Willstätter-Straße 11, 12489, Berlin, Germany
| | - Sarah Trimpin
- Department of Chemistry, Wayne State University, Detroit, MI, USA
| | - Chi-Kung Ni
- Institute of Atomic and Molecular Sciences, Academia Sinica, Taipei, Taiwan
| |
Collapse
|
18
|
Sulimenkov IV, Taziev KR, Brusov VS, Kozlovskiy VI. Using matrix-assisted ionization method for mass spectral identification of fullerene-dye conjugates. EUROPEAN JOURNAL OF MASS SPECTROMETRY (CHICHESTER, ENGLAND) 2020; 26:419-424. [PMID: 33174765 DOI: 10.1177/1469066720970520] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Traditional soft ionization methods are not always suitable for mass spectral analysis of complex compounds. Factors such as laser radiation and heating resulting in fragmentations of sample molecules in the case of matrix-assisted laser desorption/ionization and difficulties in preparing suitable sample solutions in the case of electrospray ionization make it impossible to use these methods in some cases. Matrix-assisted ionization was used to analyze products of chemical synthesis involving pyropheophorbide and fullerene. Mass spectra were acquired using a simple effective modification of the Exactive Orbitrap mass spectrometer electrospray interface. Reliable identification of pyropheophorbide-fullerene dyad ions and its derivatives was carried out. An experimental comparison of a matrix-assisted ionization and an electrospray ionization technique demonstrated the significant advantage in sensitivity to the ions under study (approximately 20 times higher) of the matrix-assisted ionization method in this particular study.
Collapse
Affiliation(s)
- Ilya V Sulimenkov
- Chernogolovka Branch of the N.N. Semenov Federal Research Center for Chemical Physics, Russian Academy of Sciences, Moscow Region, Russia
| | - Kamil R Taziev
- Institute of Problems of Chemical Physics, Russian Academy of Sciences, Moscow Region, Russia
- Fundamental Physical and Chemical Engineering Department, Lomonosov Moscow State University, Moscow, Russia
| | - Vladimir S Brusov
- Chernogolovka Branch of the N.N. Semenov Federal Research Center for Chemical Physics, Russian Academy of Sciences, Moscow Region, Russia
| | - Viatcheslav I Kozlovskiy
- Chernogolovka Branch of the N.N. Semenov Federal Research Center for Chemical Physics, Russian Academy of Sciences, Moscow Region, Russia
| |
Collapse
|
19
|
Apsokardu MJ, Krasnomowitz JM, Jiang S, Johnston MV. Ion Formation from Rapidly Heated Aqueous Droplets by Droplet-Assisted Ionization. J Phys Chem A 2020; 124:7313-7321. [PMID: 32833452 DOI: 10.1021/acs.jpca.0c07101] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
When aqueous droplets travel through a temperature-controlled capillary from atmospheric pressure into a vacuum, they undergo aerodynamic and/or thermal breakup to give charged progeny droplets that subsequently produce gas-phase molecular ions from solutes that were in the original droplets. This phenomenon is the basis of droplet-assisted ionization, a method that was recently developed for online characterization of aerosols by mass spectrometry. The conditions allowing initial droplets to break up into progeny droplets were studied by computational fluid dynamics (CFD) with a droplet evaporation model. The CFD results were then used to interpret experimental measurements of ion current vs capillary wall temperature. For capillary wall temperatures below about 150 °C, the abilities of droplets to undergo either aerodynamic or thermal breakup are strongly temperature dependent. Above this temperature, the mode of initial droplet breakup becomes temperature independent, and the temperature dependence of the ion signal intensity can be explained in relation to ion formation from charged progeny droplets. Activation energies for ion formation fall into two main categories: ∼41 kJ mol-1 for droplets containing predominantly nonionic solutes, which matches the enthalpy of vaporization for water and suggests a charge residue process for ion formation, and ∼24 kJ mol-1 for droplets containing salts, which suggests an ion evaporation process where the ion is ejected from the droplet surface within a cluster of solvent molecules.
Collapse
Affiliation(s)
- Michael J Apsokardu
- Department of Chemistry and Biochemistry, University of Delaware, Newark, Delaware 19716, United States
| | - Justin M Krasnomowitz
- Department of Chemistry and Biochemistry, University of Delaware, Newark, Delaware 19716, United States
| | - Shuai Jiang
- Department of Chemistry and Biochemistry, University of Delaware, Newark, Delaware 19716, United States
| | - Murray V Johnston
- Department of Chemistry and Biochemistry, University of Delaware, Newark, Delaware 19716, United States
| |
Collapse
|
20
|
Inutan ED, Meher AK, Karki S, Fischer JL, Imperial LF, Foley CD, Jarois DR, El-Baba TJ, Lutomski CA, Trimpin S. New mass spectrometry concepts for characterization of synthetic polymers and additives. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2020; 34 Suppl 2:e8768. [PMID: 32107802 DOI: 10.1002/rcm.8768] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/30/2019] [Revised: 02/17/2020] [Accepted: 02/19/2020] [Indexed: 06/10/2023]
Abstract
RATIONALE New ionization processes have been developed for biological mass spectrometry (MS) in which the matrix lifts the nonvolatile analyte into the gas phase as ions without any additional energy input. We rationalized that additional fundamental knowledge is needed to assess analytical utility for the field of synthetic polymers and additives. METHODS Different mass spectrometers (Thermo Orbitrap (Q-)Exactive (Focus); Waters SYNAPT G2(S)) were employed. The formation of multiply charged polymer ions upon exposure of the matrix/analyte(/salt) sample to sub-atmospheric pressure directly from the solid state and surfaces facilitates the use of advanced mass spectrometers for detection of polymeric materials including consumer products (e.g., gum). RESULTS Astonishingly, using nothing more than a small molecule matrix compound (e.g., 2-methyl-2-nitropropane-1,3-diol or 3-nitrobenzonitrile) and a salt (e.g., mono- or divalent cation(s)), such samples upon exposure to sub-atmospheric pressure transfer nonvolatile polymers and nonvolatile salts into the gas phase as multiply charged ions. These successes contradict the conventional understanding of ionization in MS, because can nonvolatile polymers be lifted in the gas phase as ions not only by as little as a volatile matrix but also by the salt required for ionizing the analyte through noncovalent metal cation adduction(s). Prototype vacuum matrix-assisted ionization (vMAI) and automated sources using a contactless approach are demonstrated for direct analyses of synthetic polymers and plasticizers, minimizing the risk of contamination using direct sample introduction into the mass spectrometer vacuum. CONCLUSIONS Direct ionization methods from surfaces without the need of high voltage, a laser, or even applied heat are demonstrated for characterization of detailed materials using (ultra)high-resolution and accurate mass measurements enabled by the multiply charged ions extending the mass range of high-performance mass spectrometers and use of a split probe sample introduction device. Our vision is that, with further development of fundamentals and dedicated sources, both spatial- and temporal-resolution measurements are within reach if sensitivity is addressed for decreasing sample-size measurements.
Collapse
Affiliation(s)
- Ellen D Inutan
- Mindanao State University-Iligan Institute of Technology, Iligan City, Philippines
- Department of Chemistry, Wayne State University, Detroit, MI, USA
- MS™, LLC, Newark, DE, USA
| | - Anil K Meher
- Department of Chemistry, Wayne State University, Detroit, MI, USA
- MS™, LLC, Newark, DE, USA
| | - Santosh Karki
- Department of Chemistry, Wayne State University, Detroit, MI, USA
- MS™, LLC, Newark, DE, USA
| | - Joshua L Fischer
- Department of Chemistry, Wayne State University, Detroit, MI, USA
| | | | - Casey D Foley
- Department of Chemistry, Wayne State University, Detroit, MI, USA
| | - Dean R Jarois
- Department of Chemistry, Wayne State University, Detroit, MI, USA
| | - Tarick J El-Baba
- Department of Chemistry, Wayne State University, Detroit, MI, USA
| | | | - Sarah Trimpin
- Department of Chemistry, Wayne State University, Detroit, MI, USA
- MS™, LLC, Newark, DE, USA
| |
Collapse
|
21
|
Banstola B, Murray KK. Sublimation Electrification of Organic Compounds. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2020; 31:888-893. [PMID: 32233384 DOI: 10.1021/jasms.9b00124] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
The electrification of crystalline deposits of organic compounds under high vacuum was measured and quantified. A group of compounds that produce multiply charged ions by matrix-assisted ionization were deposited on a metal plate, and the current was amplified and recorded; the total charge was obtained by integration of the current. Signals of several hundred picoamperes were obtained within 10 s of the application of high vacuum and persisted for several minutes as the compounds sublimed. The magnitude and sign of the charge were matrix dependent and were affected by the presence of organic or mineral acid in the crystalline deposit, as well as by the application of an electric field. The observations are interpreted as surface electrification caused by the emission of small charged matrix particles during sublimation, with ionic charge carriers comprising protons and hydroxide ions.
Collapse
Affiliation(s)
- Bijay Banstola
- Department of Chemistry, Louisiana State University, Baton Rouge, Louisiana 70803, United States
| | - Kermit K Murray
- Department of Chemistry, Louisiana State University, Baton Rouge, Louisiana 70803, United States
| |
Collapse
|
22
|
Trevorrow P, Kilgour DPA. Perspectives on the future of mass spectrometry. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2019; 33 Suppl 3:1-2. [PMID: 30414208 DOI: 10.1002/rcm.8346] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/02/2018] [Accepted: 11/02/2018] [Indexed: 06/08/2023]
Affiliation(s)
- Paul Trevorrow
- Wiley, The Atrium, Southern Gate, Chichester, PO19 8SQ, UK
| | | |
Collapse
|
23
|
Trimpin S, Inutan ED, Karki S, Elia EA, Zhang WJ, Weidner SM, Marshall DD, Hoang K, Lee C, Davis ETJ, Smith V, Meher AK, Cornejo MA, Auner GW, McEwen CN. Fundamental Studies of New Ionization Technologies and Insights from IMS-MS. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2019; 30:1133-1147. [PMID: 31062287 DOI: 10.1007/s13361-019-02194-7] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/31/2019] [Revised: 03/13/2019] [Accepted: 03/13/2019] [Indexed: 06/09/2023]
Abstract
Exceptional ion mobility spectrometry mass spectrometry (IMS-MS) developments by von Helden, Jarrold, and Clemmer provided technology that gives a view of chemical/biological compositions previously not achievable. The ionization method of choice used with IMS-MS has been electrospray ionization (ESI). In this special issue contribution, we focus on fundamentals of heretofore unprecedented means for transferring volatile and nonvolatile compounds into gas-phase ions singly and multiply charged. These newer ionization processes frequently lead to different selectivity relative to ESI and, together with IMS-MS, may provide a more comprehensive view of chemical compositions directly from their original environment such as surfaces, e.g., tissue. Similarities of results using solvent- and matrix-assisted ionization are highlighted, as are differences between ESI and the inlet ionization methods, especially with mixtures such as bacterial extracts. Selectivity using different matrices is discussed, as are results which add to our fundamental knowledge of inlet ionization as well as pose additional avenues for inquiry. IMS-MS provides an opportunity for comparison studies relative to ESI and will prove valuable using the new ionization technologies for direct analyses. Our hypothesis is that some ESI-IMS-MS applications will be replaced by the new ionization processes and by understanding mechanistic aspects to aid enhanced source and method developments this will be hastened.
Collapse
Affiliation(s)
- Sarah Trimpin
- Department of Chemistry, Wayne State University, Detroit, MI, USA.
- Cardiovascular Research Institute, School of Medicine, Wayne State University, Detroit, MI, USA.
- MSTM, LLC, Newark, DE, USA.
| | - Ellen D Inutan
- Department of Chemistry, Wayne State University, Detroit, MI, USA
- MSTM, LLC, Newark, DE, USA
- Mindanao State University-Iligan Institute of Technology, Iligan City, Philippines
| | - Santosh Karki
- Department of Chemistry, Wayne State University, Detroit, MI, USA
- MSTM, LLC, Newark, DE, USA
| | | | - Wen-Jing Zhang
- Department of Chemistry, Wayne State University, Detroit, MI, USA
| | - Steffen M Weidner
- Bundesanstalt für Materialforschung und -prüfung (BAM), Berlin, Germany
| | - Darrell D Marshall
- Department of Chemistry, Wayne State University, Detroit, MI, USA
- MSTM, LLC, Newark, DE, USA
| | - Khoa Hoang
- University of the Sciences, Philadelphia, PA, USA
| | - Chuping Lee
- Department of Chemistry, Wayne State University, Detroit, MI, USA
- MSTM, LLC, Newark, DE, USA
| | - Eric T J Davis
- Department of Chemistry, Wayne State University, Detroit, MI, USA
| | | | - Anil K Meher
- Department of Chemistry, Wayne State University, Detroit, MI, USA
| | - Mario A Cornejo
- Department of Chemistry, Wayne State University, Detroit, MI, USA
| | - Gregory W Auner
- Department of Surgery, School of Medicine, Wayne State University, Detroit, MI, USA
| | - Charles N McEwen
- MSTM, LLC, Newark, DE, USA
- University of the Sciences, Philadelphia, PA, USA
| |
Collapse
|
24
|
Ranganathan N, Li C, Suder T, Karanji AK, Li X, He Z, Valentine SJ, Li P. Capillary Vibrating Sharp-Edge Spray Ionization (cVSSI) for Voltage-Free Liquid Chromatography-Mass Spectrometry. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2019; 30:824-831. [PMID: 30793264 PMCID: PMC6560627 DOI: 10.1007/s13361-019-02147-0] [Citation(s) in RCA: 28] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/27/2018] [Revised: 01/11/2019] [Accepted: 01/30/2019] [Indexed: 05/11/2023]
Abstract
Here, we report a continuous flow-based ionization method, capillary vibrating sharp-edge spray ionization (cVSSI), that nebulizes liquid sample directly at the outlet of a capillary without using high-speed nebulization gas or a high electrical field. cVSSI is built upon the recently reported VSSI principle which nebulizes bulk liquid using vibrating sharp-edges. By attaching a short piece of fused silica capillary on top of the vibrating glass slide in VSSI, liquid is nebulized at the outlet of the capillary as the result of the vibration. Utilizing standard 360-μm OD/100-μm ID capillary, cVSSI works with a wide range of flow rates from 1 μL/min to 1 mL/min. The power consumption is as low as 130 mW. ESI-like MS spectra are obtained for small molecules, peptides, and proteins. Five orders of magnitude linear response for acetaminophen solution is achieved with a limit of detection (LOD) of 3 nM. cVSSI is also demonstrated to be compatible with LC-MS analysis. Two LC-MS applications are demonstrated with cVSSI: (1) separation and detection of a mixture of small molecules and (2) bottom-up proteomics using a protein digest. A mixture of nine common metabolites was appropriately separated and detected using LC-cVSSI-MS. In the bottom-up experiment, 78 peptides were detected using LC-cVSSI-MS/MS with a protein coverage of 100% for cytochrome c, which is comparable with the coverage obtained using LC-ESI-MS. cVSSI offers a means of interfacing LC or other continuous flow-based applications to mass spectrometers with the salient features of voltage-free, flexibility, small footprint, and low power consumption.
Collapse
Affiliation(s)
- Nandhini Ranganathan
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, WV, USA
| | - Chong Li
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, WV, USA
| | | | - Ahmad K Karanji
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, WV, USA
| | - Xiaojun Li
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, WV, USA
| | - Ziyi He
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, WV, USA
| | - Stephen J Valentine
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, WV, USA.
| | - Peng Li
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, WV, USA.
| |
Collapse
|