1
|
Rhee SJ, Woo SH, Kim JS, Yun MS, Park C, Lee SM. Radiological and clinical outcomes after Attune primary total knee arthroplasty using Stemmable Tibia: A two-year follow-up prospective bi-center study. PLoS One 2024; 19:e0309015. [PMID: 39208149 PMCID: PMC11361569 DOI: 10.1371/journal.pone.0309015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2024] [Accepted: 08/03/2024] [Indexed: 09/04/2024] Open
Abstract
This prospective bi-center study aimed to analyze the outcomes of primary total knee arthroplasty using the Stemmable Tibia Attune system. A total of 100 patients who underwent primary total knee arthroplasty with Stemmable Tibia from January 2019 to December 2021 were enrolled in the study. Radiological outcomes (hip-knee-ankle axis and medial proximal tibial angle) were assessed preoperatively and postoperatively. Clinical outcomes (visual analog scale score, Hospital for Special Surgery score, Knee Society function score, Knee Society knee score, flexion contracture, further flexion, and range of motion) were analyzed preoperatively and at 6 weeks, 3 months, 6 months, 1 year, and 2 years postoperatively. Complications (periprosthetic joint infection and aseptic loosening) were examined. The hip-knee-ankle axis decreased (preoperative: 9.5° ± 6.3°, postoperative: 1.1° ± 2.7°), whereas the medial proximal tibial angle increased (preoperative: 84.6° ± 4.1°, postoperative: 89.8° ± 1.9°). The visual analog scale score, Hospital for Special Surgery score, Knee Society knee score, and Knee Society function score increased postoperatively. The Knee Society knee score indicated above good outcomes (100.0% and 99.0% at 1 and 2 years postoperatively, respectively). The Knee Society function score also showed above good results (98.0% and 93.0% at 1 and 2 years postoperatively, respectively). The range of motion significantly improved (p < 0.001): flexion contracture decreased from 9.10° ± 7.23° to 2.15° ± 2.87°, whereas further flexion increased from 136.05° ± 14.78° to 139.80° ± 10.02°. One patient developed periprosthetic joint infection; no early loosening was observed. In conclusion, Attune primary total knee arthroplasty with Stemmable Tibia not only is safe and effective but also leads to radiological and clinical improvements.
Collapse
Affiliation(s)
- Seung Joon Rhee
- Department of Orthopedic Surgery, Biomedical Research Institute, Pusan National University Hospital, Busan, Korea
- Pusan National University, Pusan National University School of Medicine, Yangsan, Republic of Korea
| | - Seung Hun Woo
- Pusan National University, Pusan National University School of Medicine, Yangsan, Republic of Korea
- Department of Orthopedic Surgery, Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Yangsan, Korea
| | - Jung Shin Kim
- Department of Orthopedic Surgery, Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Yangsan, Korea
| | - Mi Sook Yun
- Division of Biostatistics, Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Yangsan, Korea
| | - Chankue Park
- Pusan National University, Pusan National University School of Medicine, Yangsan, Republic of Korea
- Department of Radiology, Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Yangsan, Korea
| | - Sang-Min Lee
- Pusan National University, Pusan National University School of Medicine, Yangsan, Republic of Korea
- Department of Orthopedic Surgery, Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Yangsan, Korea
| |
Collapse
|
2
|
van Duren BH, France J, Berber R, Matar HE, James PJ, Bloch BV. Is there an increased revision rate due to early tibial component loosening with a modern total knee arthroplasty design? A retrospective analysis from a large volume arthroplasty centre. ARTHROPLASTY 2024; 6:46. [PMID: 39095924 PMCID: PMC11297728 DOI: 10.1186/s42836-024-00264-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2024] [Accepted: 05/21/2024] [Indexed: 08/04/2024] Open
Abstract
BACKGROUND The Attune TKR was introduced in 2011 as a successor to its predicate design The PFC Sigma. However, following reports of early failures, there are ongoing concerns related to increased loosening rates. Given the concerns, this study aimed to compare revision rates of the Attune implant to an established predicate, and other implant designs used in a high-volume arthroplasty center. METHODS We identified 10,202 patients who underwent primary cemented TKR at our institution with a minimum of 1 year follow-up, involving 2406 Attune TKR (557 S +), 4642 PFC TKR, 3154 other designs. Primary outcomes were revision for all-causes, aseptic loosening of any component, and aseptic tibial loosening. Kaplan-Meier survival and Cox regression models were used to compare groups. Matched cohorts were selected for radiographic analysis. RESULTS 308 knees were revised. The Attune cohort had the lowest risk of revision, with a rate of 2.98 per 1000 implant-years while the PFC and All Other Implant groups had a rate of 3.15 and 4.4 respectively. Aseptic loosing was the most common cause for revision, with 76% (65/88) involving the tibia. Survival analysis showed no significant differences between the Attune and other cohorts. Radiolucent lines were detected in 7.1% of the Attune S + group, 6.8% of the standard Attune group, and 6.3% of the PFC group, with no significant differences found between them. CONCLUSION This study represents the largest non-registry review of the Attune TKR in comparison to a predicate and other designs. There was no significant increased revision rate for all-cause revision or aseptic loosening, or peri-implant radiolucencies. It appears that increased loosening may not be as concerning as originally thought. LEVEL OF EVIDENCE Level III.
Collapse
Affiliation(s)
- Bernard H van Duren
- Nottingham Elective Orthopaedic Services, Nottingham University Hospitals NHS Trust, Nottingham, NG5 1PB, UK.
- Leeds Orthopaedic and Trauma Sciences, Leeds Institute of Rheumatic and Musculoskeletal Medicine, University of Leeds, Leeds, LS2 9JT, UK.
| | - Jonathan France
- Nottingham Elective Orthopaedic Services, Nottingham University Hospitals NHS Trust, Nottingham, NG5 1PB, UK
| | - Reshid Berber
- Nottingham Elective Orthopaedic Services, Nottingham University Hospitals NHS Trust, Nottingham, NG5 1PB, UK
| | - Hosam E Matar
- Nottingham Elective Orthopaedic Services, Nottingham University Hospitals NHS Trust, Nottingham, NG5 1PB, UK
| | - Peter J James
- Nottingham Elective Orthopaedic Services, Nottingham University Hospitals NHS Trust, Nottingham, NG5 1PB, UK
| | - Benjamin V Bloch
- Nottingham Elective Orthopaedic Services, Nottingham University Hospitals NHS Trust, Nottingham, NG5 1PB, UK
- University of Nottingham, School of Medicine, Nottingham, UK
| |
Collapse
|
3
|
Wautier D, Thienpont E. Appearance and evolution of radiolucent lines below the tibial implant in primary total knee arthroplasty. Arch Orthop Trauma Surg 2024; 144:1333-1344. [PMID: 37878076 DOI: 10.1007/s00402-023-05100-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/04/2023] [Accepted: 09/30/2023] [Indexed: 10/26/2023]
Abstract
BACKGROUND The aim of this study was to evaluate total knee arthroplasty (TKA) radiographically to detect the occurrence of radiolucent lines (RLL) under the tibial base plate and to determine what type of RLL may have a correlation with aseptic loosening (AL). The study had two hypotheses: (1) RLLs may have different radiological aspects and evolutions in time depending of different factors (2) Signs of micro- and/or macro-mobility of the implant are necessary before diagnosing aseptic loosening of the tibial component. METHODS Retrospective cohort study of 774 patients operated with a Vanguard TKA (Zimmer Biomet, Warsaw, IN, US) from 2007 to 2015. RLLs were recorded in a database and described according to their radiological aspect, localization, time of apparition, progression and eventual evolution to AL. Other collected parameters were pre- and post-operative HKA angles, amount of post-operative HKA correction, surgical, clinical and demographic data. RESULTS 178/774 TKAs (23%) showed RLLs under the tibial base plate including 9 (1.2%) tibial implants needing revision for AL. Three different types and two aspects of RLLs were observed. Important deformity corrections or undercorrected implants were recognized as a mechanical risk factor for loosening. Elderly women with osteoporosis and young men with important pre-operative deformities were identified as clinical risk factors for RLLs. CONCLUSIONS RLLs are frequently present at the epiphyseal bone/implant interface after total knee arthroplasty, but do not mean the implant is loose. They can be considered a sign of reduced epiphyseal surface fixation due to micro mobility of the tibial implant. Aseptic loosening can be observed radiologically when signs of macro-mobility of the implant are present at the metaphyseal level. LEVEL OF EVIDENCE III.
Collapse
Affiliation(s)
- D Wautier
- Department of Orthopedic Surgery, CHU UCL Namur, Godinne, Avenue Docteur Gaston Therasse 1, 5530, Yvoir, Belgium.
| | - E Thienpont
- Department of Orthopedic Surgery, Cliniques Universitaires Saint-Luc, Avenue Hippocrate 10, 1200, Brussels, Belgium
| |
Collapse
|
4
|
Holzer LA, Finsterwald MA, Sobhi S, Jones CW, Yates PJ. Application of bone cement directly to the implant in primary total knee arthroplasty. Short-term radiological and clinical follow-up of two different cementing techniques. Arch Orthop Trauma Surg 2024; 144:333-340. [PMID: 37736767 DOI: 10.1007/s00402-023-05057-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/26/2023] [Accepted: 09/02/2023] [Indexed: 09/23/2023]
Abstract
PURPOSE This study aimed to optimize cement application techniques in fully cemented primary total knee arthroplasty (TKA) by comparing the effects of two different approaches: cement on bone surface (CoB) versus cement on bone surface and implant surface (CoBaI) on the short-term presence of radiolucent lines (RLL) as indicators of potential complications. METHODS In this monocentric study, a total of 379 fully cemented primary TKAs (318 patients) were included. The two study groups were differentiated by the technique of cement application: CoB group (cement applied only on bone surface) and CoBaI group (cement applied on both bone surface and implant surface). The presence of RLL or osteolysis was evaluated using the updated Knee Society Radiographic Evaluation System. RESULTS In the whole study population, RLL were present in 4.7% of cases, with a significantly higher incidence in the CoBaI group (10.5%) at the 4-week follow-up. At the 12-month follow-up, RLL were observed in 29.8% of TKAs in the CoBaI group, while the incidence was lower in the CoB group (24.0%) (not statistically significant). There were two revisions in each group, none of which were due to aseptic loosening. CONCLUSION The findings of this study suggest that the application of bone cement on bone surface only (CoB) may be more beneficial than applying it on both bone surface and implant surface (CoBaI) in terms of short-term presence of RLL in fully cemented primary TKA. Long-term results, especially with regard to aseptic loosening, will be of interest and may provide valuable guidance for future directions in bone cement applications in TKA.
Collapse
Affiliation(s)
- Lukas A Holzer
- Department of Orthopaedics, Fiona Stanley Fremantle Hospitals Group, 11 Robin Warren Dr., Murdoch, WA, 6150, Australia.
- Orthopaedic Research Foundation of Western Australia (ORFWA), Perth, WA, Australia.
- Department of Orthopaedics and Traumatology, Medical University of Innsbruck, Innsbruck, Austria.
| | - Michael A Finsterwald
- Department of Orthopaedics, Fiona Stanley Fremantle Hospitals Group, 11 Robin Warren Dr., Murdoch, WA, 6150, Australia
- Orthopaedic Research Foundation of Western Australia (ORFWA), Perth, WA, Australia
| | - Salar Sobhi
- Department of Orthopaedics, Fiona Stanley Fremantle Hospitals Group, 11 Robin Warren Dr., Murdoch, WA, 6150, Australia
- Orthopaedic Research Foundation of Western Australia (ORFWA), Perth, WA, Australia
| | - Christopher W Jones
- Department of Orthopaedics, Fiona Stanley Fremantle Hospitals Group, 11 Robin Warren Dr., Murdoch, WA, 6150, Australia
- Orthopaedic Research Foundation of Western Australia (ORFWA), Perth, WA, Australia
- Curtin University, Bentley, WA, Australia
- University of Western Australia, Crawley, WA, Australia
| | - Piers J Yates
- Department of Orthopaedics, Fiona Stanley Fremantle Hospitals Group, 11 Robin Warren Dr., Murdoch, WA, 6150, Australia
- Orthopaedic Research Foundation of Western Australia (ORFWA), Perth, WA, Australia
- University of Western Australia, Crawley, WA, Australia
- Department of Orthopaedics, St. John of God Hospital Murdoch, Murdoch, WA, Australia
| |
Collapse
|
5
|
Keiller T, Saari T, Sharegi B, Kärrholm J. No difference in clinical outcome but in RSA in total knee arthroplasty with the ATTUNE vs. the PFC Sigma: a randomized trial with 2-year follow-up. Acta Orthop 2023; 94:560-569. [PMID: 38032279 PMCID: PMC10688434 DOI: 10.2340/17453674.2023.24577] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/04/2022] [Accepted: 10/06/2023] [Indexed: 12/01/2023] Open
Abstract
BACKGROUND AND PURPOSE Despite usage of the ATTUNE total knee arthroplasty (TKA) for about 10 years, few randomized trials exist. We evaluated whether the ATTUNE CR design showed improved clinical results compared with the PFC Sigma CR after 2 years and if there was a difference in tibial component migration. PATIENTS AND METHODS 96 patients with knee osteoarthritis were randomly treated with cemented ATTUNE or PFC Sigma TKA. 42 patients with the ATTUNE and 48 with the PFC Sigma attended the 2-year follow-up. Patient-reported outcome measurements (PROMs), migration measured with RSA, implant position, and the development of radiolucent zones were studied. Non-parametric tests and repeated measures analysis were used at the statistical evaluation. RESULTS The Oxford Knee Score (OKS) at 2 years (primary outcome) and neither of the secondary PROM outcomes differed between the groups (mean difference OKS ATTUNE - PFC: -0.08, 95% confidence interval [CI] -2.9 to 2.7). RSA showed posterior tilt of the tibial component in the ATTUNE group with proximal lift-off anteriorly and subsidence of the tibial tray posteriorly. In contrast, the PFC Sigma tibial component tilted forward (mean difference ATTUNE - PFC: -0.7°, CI -1.1° to -0.4°) with maximum subsidence in the front and maximum lift-off of the posterior edge. The postoperative implant positions and the extension of radiolucent lines around the tibial component at 2 years did not differ. CONCLUSION We found no significant differences in clinical outcome between the 2 groups but minor differences in migration pattern of the tibial component. The clinical long-term significance of this finding if any is not known.
Collapse
Affiliation(s)
- Thom Keiller
- Department of Orthopaedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg; Department of Orthopaedics, Sahlgrenska University Hospital, Region Västra Götaland, Gothenburg.
| | - Tuuli Saari
- Department of Orthopaedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg; Department of Orthopaedics, Sahlgrenska University Hospital, Region Västra Götaland, Gothenburg
| | - Bita Sharegi
- Department of Orthopaedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg; Department of Orthopaedics, Sahlgrenska University Hospital, Region Västra Götaland, Gothenburg
| | - Johan Kärrholm
- Department of Orthopaedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg; Department of Orthopaedics, Sahlgrenska University Hospital, Region Västra Götaland, Gothenburg; Swedish Hip Arthroplasty Register, Gothenburg, Sweden
| |
Collapse
|
6
|
Yüksel Y, Koster LA, Kaptein BL, Nelissen RGHH, den Hollander P. No difference in component migration at five years between the cemented cruciate-retaining ATTUNE and PFC-Sigma knee prosthesis: an update of a randomized clinical radiostereometry trial. Bone Joint J 2023; 105-B:1168-1176. [PMID: 37907075 DOI: 10.1302/0301-620x.105b11.bjj-2022-0839.r4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/02/2023]
Abstract
Aims Conflicting clinical results are reported for the ATTUNE Total Knee Arthroplasty (TKA). This randomized controlled trial (RCT) evaluated five-year follow-up results comparing cemented ATTUNE and PFC-Sigma cruciate retaining TKAs, analyzing component migration as measured by radiostereometric analysis (RSA), clinical outcomes, patient-reported outcome measures (PROMs), and radiological outcomes. Methods A total of 74 primary TKAs were included in this single-blind RCT. RSA examinations were performed, and PROMs and clinical outcomes were collected immediate postoperatively, and at three, six, 12, 24, and 60 months' follow-up. Radiolucent lines (RLLs) were measured in standard anteroposterior radiographs at six weeks, and 12 and 60 months postoperatively. Results At five-year follow-up, RSA data from 61 patients were available and the mean maximum total point motion (MTPM) of the femoral components were: ATTUNE: 0.96 mm (95% confidence interval (CI) 0.79 to 1.14) and PFC-Sigma 1.37 mm (95% CI 1.18 to 1.59) (p < 0.001). The PFC-Sigma femoral component migrated more in the first postoperative year, but stabilized thereafter. MPTM of the tibial components were comparable at five-year follow-up: ATTUNE 1.12 mm (95% CI 0.95 to 1.31) and PFC-Sigma 1.25 mm (95% CI 1.07 to 1.44) (p = 0.438). RLL at the medial tibial implant-cement interface remained more prevalent for the ATTUNE at five-year follow-up compared to the PFC-Sigma (20% vs 3%). RLL did not progress over time, and varied between patients at different timepoints for both TKA systems. Clinical outcomes and PROMs improved compared with preoperative scores, and were not different between groups. Conclusion MTPM migration at five-year follow-up of the femoral and tibial component of the ATTUNE were similar and as low as that of the PFC-Sigma. MTPM migration of both knee implants did not significantly change from one year post-surgery, indicating stable fixation. Long-term ATTUNE performance may be expected to be comparable to the clinically well-performing PFC-Sigma. We have not found evidence of increased tibial component migration as measured by RSA to support concerns about cement debonding and a higher risk of aseptic loosening with the ATTUNE TKA.
Collapse
Affiliation(s)
- Yasin Yüksel
- Department of Orthopaedics, Leiden University Medical Center, Leiden, Netherlands
| | - Lennard A Koster
- Department of Orthopaedics, Leiden University Medical Center, Leiden, Netherlands
| | - Bart L Kaptein
- Department of Orthopaedics, Leiden University Medical Center, Leiden, Netherlands
| | - Rob G H H Nelissen
- Department of Orthopaedics, Leiden University Medical Center, Leiden, Netherlands
| | | |
Collapse
|
7
|
O'Donovan P, McAleese T, Harty J. Does lucency equate to revision? A five-year retrospective review of Attune and Triathlon total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 2023; 31:4773-4781. [PMID: 37516985 PMCID: PMC10598109 DOI: 10.1007/s00167-023-07509-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/15/2023] [Accepted: 07/06/2023] [Indexed: 08/01/2023]
Abstract
PURPOSE The Attune® total knee arthroplasty system was introduced in 2013 to address lingering issues of patient dissatisfaction. However, recent literature reports concerns of early tibial tray debonding. The aim of this study was to compare the incidence of radiolucent lines, survivorship and patient reported outcome-measures between the Attune® system and the well-established Triathlon® system. METHODS This retrospective database review was conducted at a single institution in Cork, Ireland. All primary Attune® (N = 445) and Triathlon® (N = 285) systems implanted between 2015 and 2016 were reviewed. Radiolucent lines were assessed for those with a minimum two-year radiological follow-up (Attune® = 338; Triathlon® = 231). X-rays were taken post op, at 6 months, 2 years and 5 years. Radiolucent lines were documented using the Modern Knee Society Radiographic System. Five-year survival was assessed using Kaplan-Meier analysis with the Log Rank method to determine statistical significance. The Oxford Knee Score and EQ-5D-5L, were collected pre-op, at 6 months, 2 years and 5 years post-operatively and compared using the Kruskal-Wallis Test. RESULTS The Attune® had a higher proportion of radiolucent lines at the tibial tray [87.1% (54/62) vs 61.4% (27/44); p = 0.001] and at the implant-cement interface [62.9% (39/62) vs 43.2% (19/44); p = 0.02]. Conversely, the Triathlon® had a higher proportion AT the femur [38.6% (17/44) vs 12.9% (8/62); p = 0.001] and at the cement-bone interface [56.8% (25/44) vs 37.1% (23/62); p = 0.02]. The overall frequency of radiolucent lines was similar in both the Attune® and Triathlon® groups [17.8%, (60/338) vs 17.7%, (41/231); p = 0.49]. There was no difference in revision-free survival analysis at 5 years (Attune® 97.8% vs Triathlon® 95.8%; p = 0.129). The Attune® performed better at 5 years in the Oxford Knee Score [Attune® = 42.6 (SD 5.2) vs Triathlon® = 41 (SD 6.4); p = 0.001] and in the EQ-5D [Attune® = 0.773 (SD 0.187) vs Triathlon® = 0.729 (SD 0.218); p = 0.013]. There was no difference at 5 years in the EQ-VAS [Attune® = 80.4 (SD 13.7) vs Triathlon® = 78.5 (SD 15.3); p = 0.25]. CONCLUSION The Attune® system exhibited a higher incidence of radiolucent lines at the tibial tray. However, this did not lead to decreased survivorship at medium term follow-up compared to the Triathlon®. Furthermore, improvements in patient reported outcomes modestly favoured the Attune® system. LEVEL OF EVIDENCE III.
Collapse
Affiliation(s)
- Paul O'Donovan
- School of Medicine, University College Cork, Brookfield Health Sciences Complex, College Road, Cork, Ireland.
- Department of Trauma and Orthopaedics, South Infirmary Victoria University Hospital, Cork, Ireland.
| | - Timothy McAleese
- Department of Trauma and Orthopaedics, South Infirmary Victoria University Hospital, Cork, Ireland
| | - James Harty
- Department of Trauma and Orthopaedics, South Infirmary Victoria University Hospital, Cork, Ireland
| |
Collapse
|
8
|
Choudhury AK, Gupta K, Ansari S, Raja BS, Paul S, Kalia RB. Modern implants in total knee arthroplasty are more patellofemoral joint friendly compared to their traditional design: a systematic review and meta-analysis. Arch Orthop Trauma Surg 2023; 143:5873-5889. [PMID: 36961568 DOI: 10.1007/s00402-023-04832-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/14/2022] [Accepted: 02/28/2023] [Indexed: 03/25/2023]
Abstract
BACKGROUND Implant designs for total knee arthroplasties (TKA) are continuously evolving to improve outcomes and satisfaction rates after TKA. The present systematic review and meta-analysis aimed to explore the evidence in the literature regarding the outcomes of the Attune knee system over the PFC Sigma knee design and investigate the advantage of one over the other. METHODS A systematic review and meta-analysis of published studies till August 2021 was performed using the defined eligibility criteria. This was a systematic review of the literature published in the Cochrane Central Register of Controlled Trials (CENTRAL) Library, PUBMED, and EMBASE. The analysis included prospective and retrospective comparative trials comparing TKA by PFC sigma or Attune posterior stabilized (PS) or cruciate-retaining (CR), fixed bearing, or rotating platform systems. Patient-reported outcome measures (PROM) and postoperative patellar complications were analysed in the studies utilizing attune knee system (modern implants) to its counterpart PFC sigma (traditional implants) for TKA. Quality assessment was conducted using NIH Quality Assessment Tool for controlled intervention studies (RCTs and case-control studies). RESULTS This review included 3 RCTs and the rest, 10 of which were non-RCT, including 5852 patients. ATTUNE designs suggested a statistically significant improvement in KSS over PFC Sigma designs. Other PROMs such as OKS and WOMAC scores yielded comparable results between the two groups. ATTUNE knee prosthesis did not result in better knee range of motion, patient satisfaction, or radiological outcomes than the PFC design. Regarding the complications, attune knee prosthesis demonstrated favourable results over PFC Sigma for anterior knee pain and patellofemoral (PF) crepitus. CONCLUSIONS The present systematic review highlights better KSS and lesser chances of PF complications favouring a modern implant design over its traditional counterpart. Other patient-reported outcome analyses at a short-term follow-up period were comparable among patients undergoing total knee replacements with two different implant designs. Radiological outcomes for component positioning also suggested similar results among the two groups.
Collapse
Affiliation(s)
- Arghya Kundu Choudhury
- Department of Orthopaedics, All India Institute of Medical Sciences, Rishikesh, Uttarakhand, 249203, India
| | - Kshitij Gupta
- Department of Orthopaedics, All India Institute of Medical Sciences, Rishikesh, Uttarakhand, 249203, India
| | - Sajid Ansari
- Department of Orthopaedics, All India Institute of Medical Sciences, Rishikesh, Uttarakhand, 249203, India
| | - Balgovind S Raja
- Department of Orthopaedics, All India Institute of Medical Sciences, Rishikesh, Uttarakhand, 249203, India
| | - Souvik Paul
- Department of Orthopaedics, All India Institute of Medical Sciences, Rishikesh, Uttarakhand, 249203, India
| | - Roop Bhushan Kalia
- Department of Orthopaedics, All India Institute of Medical Sciences, Rishikesh, Uttarakhand, 249203, India.
| |
Collapse
|
9
|
Prodromidis AD, Chloros GD, Thivaios GC, Sutton PM, Pandit H, Giannoudis PV, Charalambous CP. High rate of radiolucent lines following the cemented original design of the ATTUNE total knee arthroplasty. Bone Joint J 2023; 105-B:610-621. [PMID: 37259548 DOI: 10.1302/0301-620x.105b6.bjj-2022-0675.r1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
Aims Loosening of components after total knee arthroplasty (TKA) can be associated with the development of radiolucent lines (RLLs). The aim of this study was to assess the rate of formation of RLLs in the cemented original design of the ATTUNE TKA and their relationship to loosening. Methods A systematic search was undertaken using the Cochrane methodology in three online databases: MEDLINE, Embase, and CINAHL. Studies were screened against predetermined criteria, and data were extracted. Available National Joint Registries in the Network of Orthopaedic Registries of Europe were also screened. A random effects model meta-analysis was undertaken. Results Of 263 studies, 12 were included with a total of 3,861 TKAs. Meta-analysis of ten studies showed high rates of overall tibial or femoral RLLs for the cemented original design of the ATTUNE TKA. The overall rate was 21.4% (95% confidence interval (CI) 12.7% to 33.7%) for all types of design but was higher for certain subgroups: 27.4% (95% CI 13.4% to 47.9%) for the cruciate-retaining type, and 29.9% (95% CI 15.6% to 49.6%) for the fixed-bearing type. Meta-analysis of five studies comparing the ATTUNE TKA with other implants showed a significantly higher risk of overall tibial or femoral RLLs (odds ratio (OR) 2.841 (95% CI 1.219 to 6.623); p = 0.016) for the ATTUNE. The rates of loosening or revision for loosening were lower, at 1.2% and 0.9% respectively, but the rates varied from 0% to 16.3%. The registry data did not report specifically on the original ATTUNE TKA or on revision due to loosening, but 'all-cause' five-year revision rates for the cemented ATTUNE varied from 2.6% to 5.9%. Conclusion The original cemented ATTUNE TKA has high rates of RLLs, but their clinical significance is uncertain given the overall low associated rates of loosening and revision. However, in view of the high rates of RLLs and the variation in the rates of loosening and revision between studies and registries, close surveillance of patients who have undergone TKA with the original ATTUNE system is recommended.
Collapse
Affiliation(s)
- Apostolos D Prodromidis
- Academic Department of Trauma & Orthopaedics, School of Medicine, University of Leeds, Leeds, UK
| | - George D Chloros
- Academic Department of Trauma & Orthopaedics, School of Medicine, University of Leeds, Leeds, UK
| | | | - Paul M Sutton
- Department of Orthopaedics, Sheffield Teaching Hospitals NHS Foundation Trust, Sheffield, UK
| | - Hemant Pandit
- Department of Orthopaedics, Chapel Allerton Hospital, Leeds, UK
- Leeds Institute of Rheumatic and Musculoskeletal Medicine, University of Leeds, Leeds, UK
| | - Peter V Giannoudis
- Academic Department of Trauma & Orthopaedics, School of Medicine, University of Leeds, Leeds, UK
- NIHR Leeds Musculoskeletal Biomedical Research Unit, Leeds, UK
| | - Charalambos P Charalambous
- Department of Orthopaedics, Blackpool Teaching Hospitals NHS Foundation Trust, Blackpool, UK
- School of Medicine, University of Central Lancashire, Preston, UK
| |
Collapse
|
10
|
Stumpner T, Kuhn R, Hochreiter J, Ortmaier R. Periprosthetic knee joint infection caused by Brucella melitensis which was first -osteoarticular brucellosis or osteoarthrosis: A case report. World J Clin Cases 2023; 11:677-683. [PMID: 36793627 PMCID: PMC9923859 DOI: 10.12998/wjcc.v11.i3.677] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/24/2022] [Revised: 12/26/2022] [Accepted: 01/05/2023] [Indexed: 01/22/2023] Open
Abstract
BACKGROUND Brucellosis is the most common zoonosis worldwide and is endemic in the Middle East, Africa, Asia, and Latin America. However, it is uncommon in Central Europe, and periprosthetic infections caused by Brucella are therefore rare. Due to the low prevalence and nonspecific clinical presentation of the disease, accurate diagnosis can be challenging; no gold standard currently exists for treating brucellosis.
CASE SUMMARY Here, we present a 68-year-old Afghan woman living in Austria with a periprosthetic knee infection caused by Brucella melitensis. The interval from total knee arthroplasty to septic loosening was five years. A profound medical history and examinations suggested that the patient had been suffering from unrecognized chronic osteoarticular brucellosis prior to total knee arthroplasty. She was successfully treated by two-stage revision surgery and combined antibiotic therapy over three months.
CONCLUSION Clinicians should consider brucellosis as a possible cause of chronic arthralgia and periprosthetic infection in patients originating from countries with a high brucellosis burden.
Collapse
Affiliation(s)
- Thomas Stumpner
- Department of Orthopaedic Surgery, Ordensklinikum Linz Barmherzige Schwestern, Linz 4010, Austria
| | - Regina Kuhn
- Department of Orthopaedic Surgery, Ordensklinikum Linz Barmherzige Schwestern, Linz 4010, Austria
| | - Josef Hochreiter
- Department of Orthopaedic Surgery, Ordensklinikum Linz Barmherzige Schwestern, Linz 4010, Austria
| | - Reinhold Ortmaier
- Department of Orthopaedic Surgery, Ordensklinikum Linz Barmherzige Schwestern, Linz 4010, Austria
| |
Collapse
|
11
|
No component loosening of a cementless deep dish rotating platform knee at a 5-year follow-up. Knee Surg Sports Traumatol Arthrosc 2023; 31:969-978. [PMID: 35969255 PMCID: PMC9376574 DOI: 10.1007/s00167-022-07113-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/25/2022] [Accepted: 08/03/2022] [Indexed: 11/21/2022]
Abstract
PURPOSE Cemented fixation remains the gold standard in total knee arthroplasty. With an increasing number of younger patients undergoing total knee arthroplasty and a growing patient population demanding higher physical activity, a rising interest in discussion of cementless fixation is notable. The current scientific literature does not give a clear recommendation for or against uncemented total knee arthroplasty. The purpose of this study was the investigation of the 5-year clinical and radiographic outcomes of a cementless deep-dish rotating platform implant. METHODS A total of 91 primary cementless total knee arthroplasties were included in this single-centre prospective observational study. The primary outcome was revision rate due to aseptic component loosening. Further outcome measures were assessment of the of the radiographic outcome as well as the clinical outcome based on Range of Motion and scores such as American Knee Society Score, Oxford Knee Score, Knee Injury and Osteoarthritis Outcome Score and European Quality of Life 5 Dimension 3 Level at a follow-up of 5 years. RESULTS Mean age of the study population was 67.3 ± 6.6 years with 49.5% of the participants being female. Aseptic component loosening occurred in none of the patients. Implant survival with revision for any reason as endpoint was 97.8% (95% CI 100-96%) and 95.6% (95% CI 100-94%) with reoperation of any cause as endpoint. Radiolucent lines were detected in a total of eight cases (8.8%) and disappeared within the first year after surgery in five cases. Total Range of Motion improved significantly from 106° ± 15° preoperatively to 118° ± 10° at final FU (p < 0.001). All investigated scores improved significantly after total knee arthroplasty. CONCLUSION The results of this study reveal excellent mid-term performance of a cementless deep dish rotating platform total knee implant, with no component loosening, very low overall revision rate, only temporarily present radiolucent lines in a minority of patients and excellent clinical results. Therefore, cementless total knee arthroplasty is an appropriate treatment option for patients with severe osteoarthritis of the knee. LEVEL OF EVIDENCE Level II (prospective cohort study).
Collapse
|
12
|
Early outcomes using a 'kinematic retaining' total knee replacement - A multicentre prospective study at two years follow-up. Knee 2022; 39:62-70. [PMID: 36174347 DOI: 10.1016/j.knee.2022.09.002] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/18/2022] [Revised: 09/06/2022] [Accepted: 09/11/2022] [Indexed: 02/02/2023]
Abstract
BACKGROUND Although predictable implant longevity in total knee replacement (TKR) is now established, work continues to satisfy the demands of patients who seek full restoration of the painless function of the native knee following TKR. This prospective study examines the early clinical outcomes of 156 patients implanted with a novel 'kinematic-retaining' (KR) implant. METHODS 156 Physica KR TKRs were implanted for primary osteoarthritis at three European centres. Patients were reviewed up to two years using radiographic, clinical and functional evaluations. RESULTS Of the 137 patients retained at two years' follow up, none had been revised. Within 6 post-operative months, 51.7% and 79.9% had excellent clinical and functional KSS values respectively, increasing to 81.8% and 88.3% beyond two years. Mean KSS improvement was 34.8 (from 48.6 to 83.4). All KOOS sub-scores improved significantly with total KOOS improving from a mean of 35.5 (SD ±13.0) to 86.5 (±13.7) at two years post-operatively. Pain and sports KOOS sub-scores improved rapidly during the early post-operative periods, with sustained improvements beyond this. Mean OKS improved by 44.1 (±5.1) at two years. VAS satisfaction scores improved significantly at all time points beyond six weeks. Mean FJS-12 was 75.7 at two years, with no significant effects of age or gender. No progressive adverse radiographic features were noted. CONCLUSIONS Early clinical and radiographic outcomes of this kinematic-retaining knee prosthesis are promising, with improvements in clinical parameters similar to, or exceeding those published in other contemporary TKR designs. LEVEL OF EVIDENCE II, Multicentre Prospective cohort study.
Collapse
|
13
|
Grupp TM, Schilling C, Fritz B, Puente Reyna AL, Rusch S, Taunt C, Mihalko WM. Endurance Behavior of Cemented Tibial Tray Fixation Under Anterior Shear and Internal-External Torsional Shear Testing: A New Methodological Approach. J Arthroplasty 2022; 37:2272-2281. [PMID: 35588902 DOI: 10.1016/j.arth.2022.05.021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/27/2022] [Revised: 04/24/2022] [Accepted: 05/10/2022] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND Early total knee arthroplasty failures continue to surface in the literature. Cementation technique and implant design are two of the most important scenarios that can affect implant survivorship. Our objectives were to develop a more suitable preclinical test to evaluate the endurance of the implant-cement-bone interface under anterior shear and internal-external (I/E) torsional shear testing condition in a biomechanical sawbones. METHODS Implants tested included the AS VEGA System PS and the AS Columbus CR/PS (Aesculap AG, Germany), with zirconium nitride (ZrN) coating. Tibial implants were evaluated under anterior shear and I/E torsional shear conditions with 6 samples in 4 test groups. For the evaluation of the I/E torsional shear endurance behavior, a test setup was created allowing for clinically relevant I/E rotation with simultaneous high axial/tibio-femoral load. The test was performed with an I/E displacement of ±17.2°, for 1 million cycles with an axial preload of 3,000 N. RESULTS After the anterior shear test an implant-cement-bone fixation strength for the AS VEGA System tibial tray of 2,674 ± 754 N and for the AS Columbus CR/PS tibial tray of 2,177 ± 429 N was determined (P = .191). After I/E rotational shear testing an implant-cement-bone fixation strength for the AS VEGA System PS tray of 2,561 ± 519 N and for the AS Columbus CR/PS tray of 2,824 ± 515 N was resulted (P = .39). CONCLUSION Both methods had varying degrees of failure modes from debonding to failure of the sawbones foam. These two intense biomechanical loading tests are more strenuous and more representative of clinical activity.
Collapse
Affiliation(s)
- Thomas M Grupp
- Aesculap AG Research & Development, Tuttlingen, Germany; Ludwig Maximilians University Munich, Department of Orthopaedic and Trauma Surgery, Musculoskeletal University Center Munich (MUM), Campus Grosshadern, Munich, Germany
| | | | | | | | - Sabine Rusch
- Aesculap AG Research & Development, Tuttlingen, Germany
| | | | - William M Mihalko
- Campbell Clinic Department of Orthopaedic Surgery & Biomedical Eng., University of Tennessee Health Science Center, Memphis, Tennessee
| |
Collapse
|
14
|
Torino D, Damsgaard C, Kolessar DJ, Hayes DS, Foster B, Constantino J, Graham J. Tibial Baseplate-Cement Interface Debonding in the ATTUNE Total Knee Arthroplasty System. Arthroplast Today 2022; 17:165-171. [PMID: 36164312 PMCID: PMC9508148 DOI: 10.1016/j.artd.2022.06.012] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/16/2021] [Revised: 05/23/2022] [Accepted: 06/11/2022] [Indexed: 11/11/2022] Open
Abstract
Background Acrylic bone cement is the most common method of fixation for primary total knee arthroplasty (TKA). Several studies have described good short-term outcomes; however, there have been reports of early failures due to tibial baseplate debonding at the implant-cement interface of The ATTUNE Knee System (DePuy Synthes, West Chester, PA). We examined the causes and rates of revision in patients who underwent TKA with this system to identify factors associated with this mode of early failure. Methods A retrospective review of electronic health records between 2013 and 2018 identified all patients undergoing TKA with the ATTUNE Knee System with a minimum 2-year follow-up. Cause of revision, patient, implant, instrumentation, cement, and surgeon variables were collected. A descriptive analysis was used to identify characteristics of surgeon (fellowship-trained, surgical volume), implant (baseplate, bearing), and cement (brand, viscosity) that were associated with aseptic loosening. Results A total of 668 patients representing 742 knees were identified. Eighteen (2.4%) required a revision surgery. Aseptic loosening was the leading cause of revision surgery (n = 10, 55.6%). All failures due to aseptic loosening involved debonding of the tibial implant-cement interface. A multivariate analysis identified low-volume surgeons (9.0%, P < .0001) and 1 specific brand of high-viscosity cement (14.3%, P < .0001) as risk factors for aseptic loosening. Conclusions This study represents the largest nonregistry review of the original ATTUNE Knee System. Surgeon case volume and cement viscosity were factors associated with an increased rate of early failure due to tibial baseplate implant-cement interface debonding.
Collapse
|
15
|
Aujla RS, Woodhouse J, Ebert JR, Finsterwald M, Jones CW, Yates P, D'Alessandro P, Wood DJ. Journey-Deuce bicompartmental knee arthroplasty with the addition of computer navigation achieves good clinical outcomes and implant survival at 10 years. Knee Surg Sports Traumatol Arthrosc 2022; 30:3168-3175. [PMID: 33974113 DOI: 10.1007/s00167-021-06579-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/08/2021] [Accepted: 04/12/2021] [Indexed: 10/21/2022]
Abstract
PURPOSE To report 10-year outcomes and survivorship in patients undergoing bicompartmental knee arthroplasty (BCKA) using the Journey-Deuce prosthesis in a consecutive prospective case series. METHODS Between November 2006 and November 2009, 41 patients with a mean age of 69.6 years (range 51-86) underwent 51 bicompartmental knee arthroplasties with the Journey-Deuce knee prosthesis. All patients presented with symptomatic medial and patellofemoral compartment osteoarthritis, with intact cruciate ligaments and a preserved lateral compartment on plain radiographs and Magnetic Resonance Imaging. Clinical assessment was undertaken pre-surgery and at 1, 2, 5 and 10 years post-surgery using the Oxford Knee Score (OKS), EuroQol Group 5-Dimension self-reported questionnaire (EQ-5D) and maximal active range of motion (ROM). RESULTS 30 patients (37 knees) were followed-up at a mean time of 11.4 years (SD 1.1; range 10.5-14.0). Eight patients (ten knees) were deceased and three could not be contacted at final review. No major component revision was performed. Pre-operative OKS 25.4 (SD 5.2; range 15-40), knee flexion 116.4° (SD 10.3°; range 100°-140°) and EQ-5D 70.5 (SD 19.9; range 25-95). 10-year OKS 43.5 (SD 4.1; range 32-48), knee flexion 127.3° (SD 11.1°; range 105°-144°) and EQ-5D 77.4 (SD 9.3; range 60-100). The OKS (p < 0.0001), EQ-5D (p = 0.024) and active knee flexion ROM (p < 0.0001) all significantly improved from pre-surgery to 1-year post-surgery, with no further significant changes in these scores between any post-operative time period up until 10 years. 32% (7/22) of tibial and 45% (10/22) of femoral components showed progressive radiolucencies between 2 and 5-year and 10-year follow-up. CONCLUSIONS This is the largest cohort of patients having undergone BCKA (with the Journey-Deuce prosthesis) with longest follow-up described in the literature. At 10 years, patients presented with significantly improved clinical outcomes, comparable to other surgical arthroplasty options. No major component revision was performed. Progressive radiolucencies were noted in 32% of tibial and 45% of femoral components without corresponding clinical signs of loosening. LEVEL OF EVIDENCE Level III.
Collapse
Affiliation(s)
- Randeep S Aujla
- Fiona Stanley Fremantle Hospitals Group, Perth, WA, Australia. .,Orthopaedic Research Foundation of Western Australia, Alma St, Fremantle, Perth, WA, Australia.
| | - Jennifer Woodhouse
- HFRC Rehabilitation Clinic, 117 Stirling Highway, Nedlands, WA, 6009, Australia
| | - Jay R Ebert
- HFRC Rehabilitation Clinic, 117 Stirling Highway, Nedlands, WA, 6009, Australia.,School of Human Sciences (Exercise and Sport Science), University of Western Australia, Crawley, WA, 6009, Australia.,Orthopaedic Research Foundation of Western Australia, Alma St, Fremantle, Perth, WA, Australia
| | - Michael Finsterwald
- Fiona Stanley Fremantle Hospitals Group, Perth, WA, Australia.,Orthopaedic Research Foundation of Western Australia, Alma St, Fremantle, Perth, WA, Australia
| | - Christopher W Jones
- Fiona Stanley Fremantle Hospitals Group, Perth, WA, Australia.,Orthopaedic Research Foundation of Western Australia, Alma St, Fremantle, Perth, WA, Australia
| | - Piers Yates
- Fiona Stanley Fremantle Hospitals Group, Perth, WA, Australia.,School of Surgery (Orthopaedics), University of Western Australia, Crawley, Perth, WA, 6009, Australia.,Orthopaedic Research Foundation of Western Australia, Alma St, Fremantle, Perth, WA, Australia
| | - Peter D'Alessandro
- Fiona Stanley Fremantle Hospitals Group, Perth, WA, Australia.,School of Surgery (Orthopaedics), University of Western Australia, Crawley, Perth, WA, 6009, Australia.,Orthopaedic Research Foundation of Western Australia, Alma St, Fremantle, Perth, WA, Australia
| | - David J Wood
- School of Surgery (Orthopaedics), University of Western Australia, Crawley, Perth, WA, 6009, Australia
| |
Collapse
|
16
|
Jaeger S, Eissler M, Schwarze M, Schonhoff M, Kretzer JP, Bitsch RG. Does tibial design modification improve implant stability for total knee arthroplasty? An experimental cadaver study. Bone Joint Res 2022; 11:229-238. [PMID: 35400170 PMCID: PMC9057524 DOI: 10.1302/2046-3758.114.bjr-2021-0169.r1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/05/2022] Open
Abstract
Aims One of the main causes of tibial revision surgery for total knee arthroplasty is aseptic loosening. Therefore, stable fixation between the tibial component and the cement, and between the tibial component and the bone, is essential. A factor that could influence the implant stability is the implant design, with its different variations. In an existing implant system, the tibial component was modified by adding cement pockets. The aim of this experimental in vitro study was to investigate whether additional cement pockets on the underside of the tibial component could improve implant stability. The relative motion between implant and bone, the maximum pull-out force, the tibial cement mantle, and a possible path from the bone marrow to the metal-cement interface were determined. Methods A tibial component with (group S: Attune S+) and without (group A: Attune) additional cement pockets was implanted in 15 fresh-frozen human leg pairs. The relative motion was determined under dynamic loading (extension-flexion 20° to 50°, load-level 1,200 to 2,100 N) with subsequent determination of the maximum pull-out force. In addition, the cement mantle was analyzed radiologically for possible defects, the tibia base cement adhesion, and preoperative bone mineral density (BMD). Results The BMD showed no statistically significant difference between both groups. Group A showed for all load levels significantly higher maximum relative motion compared to group S for 20° and 50° flexion. Group S improved the maximum failure load significantly compared to group A without additional cement pockets. Group S showed a significantly increased cement adhesion compared to group A. The cement penetration and cement mantle defect analysis showed no significant differences between both groups. Conclusion From a biomechanical point of view, the additional cement pockets of the component have improved the fixation performance of the implant. Cite this article: Bone Joint Res 2022;11(4):229–238.
Collapse
Affiliation(s)
- Sebastian Jaeger
- Laboratory of Biomechanics and Implant Research, Department of Orthopaedic Surgery, Heidelberg University Hospital, Heidelberg, Germany
| | - Marvin Eissler
- Department of Diagnostic and Interventional Radiology, Heidelberg University Hospital, Heidelberg, Germany
| | - Martin Schwarze
- Laboratory of Biomechanics and Implant Research, Department of Orthopaedic Surgery, Heidelberg University Hospital, Heidelberg, Germany
| | - Mareike Schonhoff
- Laboratory of Biomechanics and Implant Research, Department of Orthopaedic Surgery, Heidelberg University Hospital, Heidelberg, Germany
| | - J Philippe Kretzer
- Laboratory of Biomechanics and Implant Research, Department of Orthopaedic Surgery, Heidelberg University Hospital, Heidelberg, Germany
| | - Rudi G Bitsch
- Laboratory of Biomechanics and Implant Research, Department of Orthopaedic Surgery, Heidelberg University Hospital, Heidelberg, Germany.,ATOS Clinic Heidelberg, Heidelberg University, Heidelberg, Germany
| |
Collapse
|
17
|
Fuchs A, Häussermann P, Hömig D, Ochs BG, Klopfer T, Müller CA, Helwig P, Konstantinidis L. 10-year follow-up of the Columbus knee prostheses system in a prospective multicenter study. Arch Orthop Trauma Surg 2022; 142:2875-2883. [PMID: 34505167 PMCID: PMC9474348 DOI: 10.1007/s00402-021-04156-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/07/2021] [Accepted: 08/30/2021] [Indexed: 12/01/2022]
Abstract
INTRODUCTION As endpoint of a prospective multicenter 10-year documentation using the Columbus system, this evaluation carried out results of clinical scores (Knee Society Score and Oxford Knee Score), an evaluation of radiological imaging, survival rates and a collection of complication statistics. MATERIALS AND METHODS There was a multicenter prospective recruitment of consecutive patients with the indication for total knee replacement (TKR). Preoperatively and 10 years after implantation, clinical scores, range of motion and radiological imaging was performed. During this period, a detailed documentation of complications was made. RESULTS A total of 210 patients were recruited in 5 centers. 140 patients were available for endpoint examination 10 years after surgery. A survival rate of 96.6% (CI 95%) for the implanted Columbus prostheses after 10 years was demonstrated. Cumulative KSS showed an improvement of 75.3 (± 38.1) points and was highly significant (p < 0.0001, t test). The average functional improvement in the Oxford score was 20.6 (± 9.5) points and was also highly significant (p < 0.0001). The ROM improved from 106.5° (± 20.5) preoperatively to 116.0° (± 11.5) (p < 0.0001, t test). There were no implant-related complications as well as no new complication documented between 5- and 10-year follow-up. CONCLUSIONS The endpoint analysis after an observation period of 10 years provided good clinical and radiographic results. In particular, an excellent survival rate of 96.6% after 10 years was demonstrated. The data published in this study are the first to be available in a prospective multicenter study on this system, which leads to a high level of clinical significance.
Collapse
Affiliation(s)
- Andreas Fuchs
- Department of Orthopedics and Trauma Surgery, Faculty of Medicine, Medical Center, Albert-Ludwigs-University of Freiburg, Hugstetter Straße 55, 79016 Freiburg, Germany
| | - Philip Häussermann
- Clinic for Orthopedics and Trauma Surgery, Sana Kliniken Leipziger Land, Borna, Germany
| | - Dirk Hömig
- Clinic for Orthopaedic Surgery, Ortenau Klinikum, Offenburg, Gengenbach, Germany
| | | | - Tim Klopfer
- Clinic for Trauma Surgery, BG-Klinik Tübingen, Tübingen, Germany
| | - Christof A. Müller
- Clinic for Trauma, Hand and Orthopaedic Surgery, Städtisches Klinikum Karlsruhe gGmbH, Karlsruhe, Germany
| | - Peter Helwig
- Clinic for Orthopedics and Trauma Surgery, Klinikum Heidenheim, Heidenheim, Germany
| | - Lukas Konstantinidis
- Department of Orthopedics and Trauma Surgery, Faculty of Medicine, Medical Center, Albert-Ludwigs-University of Freiburg, Hugstetter Straße 55, 79016 Freiburg, Germany
| |
Collapse
|
18
|
Cox ZC, Green CC, Otero JE, Mason JB, Martin JR. Varus Collapse in Total Knee Arthroplasty: Does Fixation or Bone Fail First? J Arthroplasty 2022; 37:162-167. [PMID: 34592354 DOI: 10.1016/j.arth.2021.09.012] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/14/2021] [Revised: 09/13/2021] [Accepted: 09/20/2021] [Indexed: 02/02/2023] Open
Abstract
INTRODUCTION Aseptic tibial loosening is now considered the most common reason that total knee arthroplasties (TKA) fail long term. There are unique subsets of patients that fail into varus alignment of the tibial tray with collapse of the medial proximal tibia. It is currently unknown if the implant fixation fails first or if the proximal medial tibia collapses first. MATERIALS We performed a retrospective analysis of 88 patients that were revised at our institution secondary to aseptic varus collapse of the proximal tibia. Two fellowship-trained arthroplasty surgeons performed a retrospective analysis on sequential precollapse radiographs in each patient to determine which failed first: the implant fixation (implant-cement or cement-bone interface) or the medial proximal tibia. DISCUSSION 36/88 (40.9%) patients had a series of precollapse radiographs that could be reviewed. Failure at the implant-cement interface before varus collapse in 23 vs 22 patients, failure at the implant-cement and cement-bone interface before varus collapse in two patients, and contemporaneous failure at the implant-cement interface and varus collapse in 11 vs 12 patients were identified by reviewers one and two, respectively. CONCLUSION The most frequent mechanism of failure identified was failure of the implant-cement interface followed by subsequent medial tibial varus collapse. Improving implant fixation may decrease the incidence of this unique failure mechanism. We advocate the use of supplemental stem fixation in high-risk patients and optimal cement techniques for all patients as methods of potentially avoiding tibial varus collapse, one of the most frequent modes of long-term failure.
Collapse
Affiliation(s)
- Zach C Cox
- OrthoCarolina Hip and Knee Center, Charlotte, NC
| | - Cody C Green
- OrthoCarolina Hip and Knee Center, Charlotte, NC
| | | | | | | |
Collapse
|
19
|
Jaeger S, Eissler M, Schwarze M, Schonhoff M, Kretzer JP, Bitsch RG. Cement debonding behaviors of the various tibial components of the ATTUNE knee system and its predecessors: Is a cement-in-cement revision an alternative? Knee 2021; 33:185-192. [PMID: 34638017 DOI: 10.1016/j.knee.2021.09.010] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/15/2021] [Revised: 09/08/2021] [Accepted: 09/20/2021] [Indexed: 02/02/2023]
Abstract
BACKGROUND Aseptic loosening remains one of the most common causes of revision of the tibial component for total knee arthroplasty. A stable bond between implant and cement is essential for appropriate long-term results. The aim of our in vitro study was to investigate the maximum failure load of tibial ATTUNE prosthesis design alternatives compared with a previous design. In addition, cement-in-cement revision was considered as a potential strategy after tibial component debonding. METHODS The experimental investigations of the maximum failure load of the implant-cement interface were performed under optimal conditions, without potential contamination. We compared the designs of the tibial components of the ATTUNE, ATTUNE S+ and P.F.C. Sigma. In addition, we investigated the cement-in-cement revision for the ATTUNE knee system replacing it with an ATTUNE S+. RESULTS The maximum failure load showed no significant difference between P.F.C. Sigma and ATTUNE groups (P = 0.087), but there was a significant difference between the P.F.C. Sigma and the ATTUNE S+ groups (P < 0.001). The analysis also showed a significant difference (P < 0.001) between the ATTUNE and the ATTUNE S+ groups for the maximum failure load. The ATTUNE S+ cement-in-cement revision group showed a significant higher failure load (P < 0.001) compared with the P.F.C. Sigma and ATTUNE groups. No significant differences (P = 1.000) were found between the ATTUNE S+ cement-in-cement and ATTUNE S+ group. CONCLUSION Based on these results, we found no design-specific evidence of increased debonding risk with the ATTUNE and ATTUNE S+ components compared with the P.F.C Sigma. Furthermore, the cement-in-cement revision seems to be an alternative for the revision surgery.
Collapse
Affiliation(s)
- Sebastian Jaeger
- Laboratory of Biomechanics and Implant Research, Clinic for Orthopedics and Trauma Surgery, Heidelberg University Hospital, Heidelberg, Germany.
| | - Marvin Eissler
- Laboratory of Biomechanics and Implant Research, Clinic for Orthopedics and Trauma Surgery, Heidelberg University Hospital, Heidelberg, Germany
| | - Martin Schwarze
- Laboratory of Biomechanics and Implant Research, Clinic for Orthopedics and Trauma Surgery, Heidelberg University Hospital, Heidelberg, Germany; Clinic for Orthopedics and Trauma Surgery, Heidelberg University Hospital, Heidelberg, Germany
| | - Mareike Schonhoff
- Laboratory of Biomechanics and Implant Research, Clinic for Orthopedics and Trauma Surgery, Heidelberg University Hospital, Heidelberg, Germany
| | - Jan Philippe Kretzer
- Laboratory of Biomechanics and Implant Research, Clinic for Orthopedics and Trauma Surgery, Heidelberg University Hospital, Heidelberg, Germany
| | - Rudi G Bitsch
- Laboratory of Biomechanics and Implant Research, Clinic for Orthopedics and Trauma Surgery, Heidelberg University Hospital, Heidelberg, Germany; ATOS Clinic Heidelberg, Heidelberg, Germany
| |
Collapse
|
20
|
Moewis P, Kaiser R, Trepczynski A, von Tycowicz C, Krahl L, Ilg A, Holz J, Duda GN. Patient-specific resurfacing implant knee surgery in subjects with early osteoarthritis results in medial pivot and lateral femoral rollback during flexion: a retrospective pilot study. Knee Surg Sports Traumatol Arthrosc 2021; 31:1247-1266. [PMID: 34601628 PMCID: PMC10050034 DOI: 10.1007/s00167-021-06749-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/31/2021] [Accepted: 09/09/2021] [Indexed: 10/20/2022]
Abstract
PURPOSE Metallic resurfacing implants have been developed for the treatment of early, small, condylar and trochlear osteoarthritis (OA) lesions. They represent an option for patients who do not fulfill the criteria for unicompartmental knee arthroplasty (UKA) or total knee arthroplasty (TKA) or are too old for biological treatment. Although clinical evidence has been collected for different resurfacing types, the in vivo post-operative knee kinematics remain unknown. The present study aims to analyze the knee kinematics in subjects with patient-specific episealer implants. This study hypothesized that patient-specific resurfacing implants would lead to knee kinematics close to healthy knees, resulting in medial pivot and a high degree of femoral rollback during flexion. METHODS Retrospective study design. Fluoroscopic analysis during unloaded flexion-extension and loaded lunge was conducted at > 12 months post-surgery in ten episealer knees, and compared to ten healthy knees. Pre- and post-operative clinical data of the episealer knees were collected using a visual analog scale (VAS), the EQ 5d Health, and the Knee Injury and Osteoarthritis Outcome Score (KOOS) questionnaires. RESULTS A consistent medial pivot was observed in both episealer and healthy knees. Non-significant differences were found in the unloaded (p = 0.15) and loaded (p = 0.51) activities. Although lateral rollback was observed in both groups, it was significantly higher for the episealer knees in both the unloaded (p = 0.02) and loaded (p = 0.01) activities. Coupled axial rotation was significantly higher in the unloaded (p = 0.001) but not in the loaded (p = 0.06) activity in the episealer knees. Improved scores were observed at 1-year post-surgery in the episealer subjects for the VAS (p = 0.001), KOOS (p = 0.001) and EQ Health (p = 0.004). CONCLUSION At 12 month follow-up, a clear physiological knee kinematics pattern of medial pivot, lateral femoral rollback and coupled axial external femoral rotation during flexion was observed in patients treated with an episealer resurfacing procedure. However, higher femoral rollback and axial external rotation in comparison to healthy knees was observed, suggesting possible post-operative muscle weakness and consequent insufficient stabilization at high flexion.
Collapse
Affiliation(s)
- Philippe Moewis
- Berlin Institute of Health at Charité-Universitätsmedizin Berlin, Julius Wolff Institute, Augustenburger Platz 1, 13353, Berlin, Germany.
| | - René Kaiser
- OrthoCentrum Hamburg, Hansastrasse 1-3, 20149, Hamburg, Germany
| | - Adam Trepczynski
- Berlin Institute of Health at Charité-Universitätsmedizin Berlin, Julius Wolff Institute, Augustenburger Platz 1, 13353, Berlin, Germany
| | | | - Leonie Krahl
- Berlin Institute of Health at Charité-Universitätsmedizin Berlin, Julius Wolff Institute, Augustenburger Platz 1, 13353, Berlin, Germany
| | - Ansgar Ilg
- OrthoCentrum Hamburg, Hansastrasse 1-3, 20149, Hamburg, Germany
| | - Johannes Holz
- OrthoCentrum Hamburg, Hansastrasse 1-3, 20149, Hamburg, Germany
| | - Georg N Duda
- Berlin Institute of Health at Charité-Universitätsmedizin Berlin, Julius Wolff Institute, Augustenburger Platz 1, 13353, Berlin, Germany
| |
Collapse
|
21
|
Bhalekar RM, Nargol ME, Shyam N, Nargol AVF, Wells SR, Collier R, Pabbruwe M, Joyce TJ, Langton DJ. Tibial tray debonding from the cement mantle is associated with deformation of the backside of polyethylene tibial inserts. Bone Joint J 2021; 103-B:1791-1801. [PMID: 34474593 DOI: 10.1302/0301-620x.103b.bjj-2020-2555.r2] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
AIMS The aim of this study was to investigate whether wear and backside deformation of polyethylene (PE) tibial inserts may influence the cement cover of tibial trays of explanted total knee arthroplasties (TKAs). METHODS At our retrieval centre, we measured changes in the wear and deformation of PE inserts using coordinate measuring machines and light microscopy. The amount of cement cover on the backside of tibial trays was quantified as a percentage of the total surface. The study involved data from the explanted fixed-bearing components of four widely used contemporary designs of TKA (Attune, NexGen, Press Fit Condylar (PFC), and Triathlon), revised for any indication, and we compared them with components that used previous generations of PE. Regression modelling was used to identify variables related to the amount of cement cover on the retrieved trays. RESULTS A total of 114 explanted fixed-bearing TKAs were examined. This included 76 used with contemporary PE inserts which were compared with 15 used with older generation PEs. The Attune and NexGen (central locking) trays were found to have significantly less cement cover than Triathlon and PFC trays (peripheral locking group) (p = 0.001). The median planicity values of the PE inserts used with central locking trays were significantly greater than of those with peripheral locking inserts (205 vs 85 microns; p < 0.001). Attune and NexGen inserts had a characteristic pattern of backside deformation, with the outer edges of the PE deviating inferiorly, leaving the PE margins as the primary areas of articulation. CONCLUSION Explanted TKAs with central locking mechanisms were significantly more likely to debond from the cement mantle. The PE inserts of these designs showed characteristic patterns of deformation, which appeared to relate to the manufacturing process and may be exacerbated in vivo. This pattern of deformation was associated with PE wear occurring at the outer edges of the articulation, potentially increasing the frictional torque generated at this interface. Cite this article: Bone Joint J 2021;103-B(12):1791-1801.
Collapse
Affiliation(s)
| | | | | | | | | | - Ryan Collier
- Centre for Implant Technology and Retrieval Analysis, Department of Medical Engineering and Physics, Royal Perth Hospital, Perth, Australia
| | - Moreica Pabbruwe
- Centre for Implant Technology and Retrieval Analysis, Department of Medical Engineering and Physics, Royal Perth Hospital, Perth, Australia
| | - Thomas J Joyce
- School of Engineering, Newcastle University, Newcastle upon Tyne, UK
| | | |
Collapse
|
22
|
Shetty G, Khairkar S. Loading on Attune® fixed-bearing cruciate-substituting total knee implant in knee malalignment during activities of daily living: A finite element analysis. J Orthop 2021; 26:36-41. [PMID: 34290486 DOI: 10.1016/j.jor.2021.07.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/16/2021] [Accepted: 07/08/2021] [Indexed: 10/20/2022] Open
Abstract
Purpose To compare contact stresses between Attune® and PFC Sigma® total knee arthroplasty (TKA) implants in the presence of knee malalignment. Methods Maximum contact stress after finite element analysis were compared during standing, walking, and stair climbing in 0°, 2.5° and 5°varus/valgus knee alignments. Results The percentage increase in contact stress was highest during walking with PFC Sigma® in 5° varus (238.5%), standing with Attune® in 5° valgus (127.2%), and standing with Attune® in 2.5° valgus (107.8%). Conclusion The newer Attune® design may be associated with higher maximum contact stresses and increased risk of wear and implant failure.
Collapse
Affiliation(s)
- Gautam Shetty
- Knee & Orthopaedic Clinic, Mumbai, India.,AIMD Research, Mumbai, India
| | - Shruti Khairkar
- Department of Mechanical Engineering, IIT Bombay, Mumbai, India
| |
Collapse
|
23
|
Lachiewicz PF, Steele JR, Wellman SS. Unexpected high rate of revision of a modern cemented fixed bearing modular posterior-stabilized knee arthroplasty. Bone Joint J 2021; 103-B:137-144. [PMID: 34053294 DOI: 10.1302/0301-620x.103b6.bjj-2020-1956.r1] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
AIMS To establish our early clinical results of a new total knee arthroplasty (TKA) tibial component introduced in 2013 and compare it to other designs in use at our hospital during the same period. METHODS This is a retrospective study of 166 (154 patients) consecutive cemented, fixed bearing, posterior-stabilized (PS) TKAs (ATTUNE) at one hospital performed by five surgeons. These were compared with a reference cohort of 511 knees (470 patients) of other designs (seven manufacturers) performed at the same hospital by the same surgeons. There were no significant differences in age, sex, BMI, or follow-up times between the two cohorts. The primary outcome was revision performed or pending. RESULTS In total, 19 (11.5%) ATTUNE study TKAs have been revised at a mean 30.3 months (SD 15), and loosening of the tibial component was seen in 17 of these (90%). Revision is pending in 12 (7%) knees. There was no difference between the 31 knees revised or with revision pending and the remaining 135 study knees in terms of patient characteristics, type of bone cement (p = 0.988), or individual surgeon (p = 0.550). In the reference cohort, there were significantly fewer knees revised (n = 13, 2.6%) and with revision pending (n = 8, 1.5%) (both p < 0.001), and only two had loosening of the tibial component as the reason for revision. CONCLUSION This new TKA design had an unexpectedly high early rate of revision compared with our reference cohort of TKAs. Debonding of the tibial component was the most common reason for failure. Additional longer-term follow-up studies of this specific component and techniques for implantation are warranted. The version of the ATTUNE tibial component implanted in this study has undergone modifications by the manufacturer. Cite this article: Bone Joint J 2021;103-B(6 Supple A):137-144.
Collapse
Affiliation(s)
- Paul F Lachiewicz
- Department of Orthopaedic Surgery, Duke University, Durham, North Carolina, USA.,Department of Surgery, Durham Veterans Affairs Medical Center, Durham, North Carolina, USA
| | - John R Steele
- Department of Orthopaedic Surgery, Duke University, Durham, North Carolina, USA
| | - Samuel S Wellman
- Department of Orthopaedic Surgery, Duke University, Durham, North Carolina, USA.,Department of Surgery, Durham Veterans Affairs Medical Center, Durham, North Carolina, USA
| |
Collapse
|
24
|
Early tibial loosening of the cemented ATTUNE knee arthroplasty - Just a question of design? Knee 2021; 30:170-175. [PMID: 33933907 DOI: 10.1016/j.knee.2021.01.003] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/14/2020] [Revised: 12/23/2020] [Accepted: 01/03/2021] [Indexed: 02/02/2023]
Abstract
BACKGROUND Total knee arthroplasty is a very successful standard treatment for severe osteoarthritis. Nevertheless, the literature reports tibial debonding between implant and bone cement as well as radiolucent lines related to the tibial components of different knee systems. Regardless of cementing techniques and the influences during surgery, we examined the design of a newly developed knee system and its predecessors (Attune, Attune S+, P.F.C. Sigma, P.F.C. Sigma RP/M.B.T., all DePuy). METHODS We investigated the dimensions of the tibial components and the fit between them and their bone bed after instrumentation in a foam material. RESULTS Our results showed considerable differences for the used knee prostheses as well as their tibial instrumentation options with a corresponding risk for incomplete seating. CONCLUSION The orthopedic surgeons need to be aware of these design features and the resulting increased seating resistance especially in hard and sclerotic bone. ARTICLE FOCUS Comparison of the tibial instruments and the different design options of the Attune knee system and its predecessor knee prostheses. KEY MESSAGES The Attune implant showed incomplete seating because of too much press fit and an uneven bone quality or sclerosis can result in tilting of the tibial component. STRENGTHS AND LIMITATIONS This is the first study investigating the Attune knee and its predecessor in terms of implant seating and press fit. The foam material is a limitation.
Collapse
|
25
|
Hauer G, Hörlesberger N, Klim S, Bernhardt GA, Leitner L, Glehr M, Leithner A, Sadoghi P. Mid-term results show no significant difference in postoperative clinical outcome, pain and range of motion between a well-established total knee arthroplasty design and its successor: a prospective, randomized, controlled trial. Knee Surg Sports Traumatol Arthrosc 2021; 29:827-831. [PMID: 32333057 PMCID: PMC7917040 DOI: 10.1007/s00167-020-06027-z] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/14/2020] [Accepted: 04/21/2020] [Indexed: 01/17/2023]
Abstract
PURPOSE The purpose of this study was to compare the clinical and functional outcome scores following total knee arthroplasty (TKA) with two different systems. The hypothesis was that there is a difference between patients receiving the newer design than those receiving the predecessor. METHODS Two hundred patients who underwent TKA were randomized into two groups: patients received either Attune TKA or PFC Sigma (both DePuy Synthes, Warsaw, IN). Clinically, the Knee Society Knee and Function Scores (KS and FS), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), Range of Motion (ROM) and Visual Analogue Scale (VAS) were evaluated and compared between the groups 2 years after surgery. 158 patients (80 in the Attune group and 78 in the PFC Sigma group) were available for follow-up. RESULTS Through bivariate analysis using parametric and non-parametric statistical tests, no significant differences in postoperative KS, FS, WOMAC, ROM or VAS between the two groups were detected. Both groups significantly improved regarding all evaluated endpoints 2 years after surgery. CONCLUSIONS In the current study population, no difference in clinical outcome between the two systems was found. The expected benefits of design modifications could not be observed in clinical outcome scores 2 years postoperatively. Both designs are effective options for improving pain and function in end-stage osteoarthritis. LEVEL OF EVIDENCE I.
Collapse
Affiliation(s)
- Georg Hauer
- Department of Orthopaedics and Trauma, Medical University of Graz, Auenbruggerplatz 5, 8036, Graz, Austria
| | - Nina Hörlesberger
- Department of Orthopaedics and Trauma, Medical University of Graz, Auenbruggerplatz 5, 8036, Graz, Austria
| | - Sebastian Klim
- Department of Orthopaedics and Trauma, Medical University of Graz, Auenbruggerplatz 5, 8036, Graz, Austria
| | - Gerwin A Bernhardt
- Department of Orthopaedics and Trauma, Medical University of Graz, Auenbruggerplatz 5, 8036, Graz, Austria
| | - Lukas Leitner
- Department of Orthopaedics and Trauma, Medical University of Graz, Auenbruggerplatz 5, 8036, Graz, Austria
| | - Mathias Glehr
- Department of Orthopaedics and Trauma, Medical University of Graz, Auenbruggerplatz 5, 8036, Graz, Austria
| | - Andreas Leithner
- Department of Orthopaedics and Trauma, Medical University of Graz, Auenbruggerplatz 5, 8036, Graz, Austria
| | - Patrick Sadoghi
- Department of Orthopaedics and Trauma, Medical University of Graz, Auenbruggerplatz 5, 8036, Graz, Austria.
| |
Collapse
|
26
|
Schwarze M, Schonhoff M, Beckmann NA, Eckert JA, Bitsch RG, Jäger S. Femoral Cementation in Knee Arthroplasty-A Comparison of Three Cementing Techniques in a Sawbone Model Using the ATTUNE Knee. J Knee Surg 2021; 34:258-266. [PMID: 31434146 DOI: 10.1055/s-0039-1694795] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Femoral component loosening is a rare but severe complication in total knee arthroplasty. Former studies have repeatedly demonstrated radiolucent lines behind the ventral and dorsal anchoring shields of the femoral components, which has led us to investigate this matter further. Therefore, three different cementing techniques were tested in a group of nine Sawbone samples each. These differed in the amount of cement applied on the femoral component as well as in the pressure application. Computed tomography was performed to evaluate and classify the cement penetration into the bone adjacent to the prosthesis according to the zones defined by the Knee Society scoring system. The results show significantly deeper cement penetration in all zones when a pressurizer is used. In the other two groups, no significant difference in the dorsal bevel cement penetration was noted. Additionally, no difference in ventral and dorsal cement penetrations (Zones 1 and 4) was delineated. In contrast, there was a significant difference in both the ventral bevel (Zone 2) as well as the distal anchoring surface (Zones 5-7). The use of a pressurizer results in greater cement penetration into all anchoring areas. Completely covering the component back surface results in a significantly higher penetration, which is mainly due to differences in volume. These data show significantly improved cementation results when using a pressurizer. Whether this improves the biomechanical properties and ultimately the revision rate requires further investigation.
Collapse
Affiliation(s)
- M Schwarze
- Clinic for Orthopedics and Trauma Surgery, Center for Orthopedics, Trauma Surgery and Spinal Cord Injury, Heidelberg University Hospital, Heidelberg, Germany
| | - M Schonhoff
- Laboratory of Biomechanics and Implant Research, Center for Orthopedics and Trauma Surgery and Spinal Cord Injury, Heidelberg University Hospital, Heidelberg, Germany
| | - N A Beckmann
- Clinic for Orthopedics and Trauma Surgery, Center for Orthopedics, Trauma Surgery and Spinal Cord Injury, Heidelberg University Hospital, Heidelberg, Germany
| | - J A Eckert
- Clinic for Orthopedics and Trauma Surgery, Center for Orthopedics, Trauma Surgery and Spinal Cord Injury, Heidelberg University Hospital, Heidelberg, Germany
| | - R G Bitsch
- Clinic for Orthopedics and Trauma Surgery, Center for Orthopedics, Trauma Surgery and Spinal Cord Injury, Heidelberg University Hospital, Heidelberg, Germany.,ATOS Clinic Heidelberg, Bismarckstrasse, Heidelberg, Germany
| | - S Jäger
- Laboratory of Biomechanics and Implant Research, Center for Orthopedics and Trauma Surgery and Spinal Cord Injury, Heidelberg University Hospital, Heidelberg, Germany
| |
Collapse
|
27
|
Moewis P, Duda GN, Trepczynski A, Krahl L, Boese CK, Hommel H. Retention of Posterior Cruciate Ligament Alone May Not Achieve Physiological Knee Joint Kinematics After Total Knee Arthroplasty: A Retrospective Study. J Bone Joint Surg Am 2021; 103:146-154. [PMID: 33060427 DOI: 10.2106/jbjs.20.00024] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND The apparently physiological kinematics of the bicruciate-stabilized total knee arthroplasty (BCS TKA) systems have been attributed to the anterior and posterior post-cam mechanism. Although comparisons between TKA designs with either a retained or a sacrificed cruciate ligament have been conducted, we are not aware of any analyses of 2 implants with identical bearing geometry but different cruciate-ligament strategies under equal loading conditions. Knowledge about the kinematic effect of the different cruciate ligament strategies would potentially be valuable to facilitate preoperative planning and decision-making with regard to selecting the most appropriate implant for a patient. METHODS This retrospective study included 20 patients: 10 treated with a BCS and 10 treated with a cruciate retaining (CR) TKA. Fluoroscopic analyses during high-flexion activities (unloaded flexion-extension and loaded lunge) were conducted at 24 months postsurgery. All patients completed the Knee Society Score, Forgotten Joint Score, and High-Flexion Knee Score questionnaires preoperatively and postoperatively. RESULTS The BCS cohort showed greater femoral lateral rollback as well as a medial pivot in both activities. In contrast, the CR cohort showed a significant increase in anterior translation on the medial compartment as well as almost absent femoral lateral rollback. Higher clinical scores were observed in the BCS cohort. CONCLUSIONS At 24 months postsurgery, despite equal bearing geometry, retention of the posterior cruciate ligament in the CR cohort apparently was insufficient to reduce anterior shift. The BCS cohort showed expected knee joint kinematics; however, the kinematics in this cohort could eventually benefit from a smooth transition between the interchanging surfaces. Further investigation should be focused on the surgical technique and its interaction with the TKA design. LEVEL OF EVIDENCE Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.
Collapse
Affiliation(s)
- Philippe Moewis
- Julius Wolff Institute and Center for Musculoskeletal Surgery, Charité-Universitätsmedizin Berlin, Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Berlin, Germany
| | - Georg N Duda
- Julius Wolff Institute and Center for Musculoskeletal Surgery, Charité-Universitätsmedizin Berlin, Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Berlin, Germany
| | - Adam Trepczynski
- Julius Wolff Institute and Center for Musculoskeletal Surgery, Charité-Universitätsmedizin Berlin, Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Berlin, Germany
| | - Leonie Krahl
- Julius Wolff Institute and Center for Musculoskeletal Surgery, Charité-Universitätsmedizin Berlin, Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Berlin, Germany
| | - Christoph K Boese
- Department of Orthopedics and Trauma Surgery, University Hospital of Cologne, Cologne, Germany.,Smith & Nephew GmbH, Hamburg, Germany
| | - Hagen Hommel
- Krankenhaus Märkisch-Oderland GmBH, Wriezen, Germany.,Medizinischen Hochschule Brandenburg (MHB) Theodor Fontane, Neuruppin, Germany
| |
Collapse
|
28
|
Kelly BC, Owen JR, Shah SC, Johnson AJ, Golladay GJ, Kates SL. A Biomechanical Comparison of the Effect of Baseplate Design and Bone Marrow Fat Infiltration on Tibial Baseplate Pullout Strength. J Arthroplasty 2021; 36:356-361. [PMID: 32829970 DOI: 10.1016/j.arth.2020.07.049] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/13/2020] [Revised: 07/07/2020] [Accepted: 07/20/2020] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND Early clinical results of a new total knee arthroplasty (TKA) implant design show promise for improved outcomes and patellofemoral function scores. However, reports of early tibial component-cement interface debonding requiring revision have been published. This study investigated the biomechanical properties of three different tibial baseplates to understand potential causes of failure. METHODS PFC Sigma (control), Attune (1st generation) and Attune S+ (2nd generation) tibial baseplates were implanted into 4th generation sawbone tibia models using a standardized technique. Three of each baseplate were cemented with and without additional bovine bone marrow fat. All models were tested to failure with measured axial distraction force. Implant type, presence or absence of bovine marrow and load to failure were all recorded and compared. Two-way ANOVA followed by post-hoc pairwise comparisons were used to determine statistical significance, which was set to P < .05. RESULTS The 2nd generation tibial baseplates required significantly more force to failure. The presence of bovine marrow significantly reduced the pullout force of the implant designs overall. No significant difference was detected between the 1st generation and control baseplates. Failure mode for each model was also noted to be different irrespective of the presence or absence of bone marrow fat. CONCLUSION The 2nd generation baseplates required significantly more force to failure compared with older designs. The presence of bone marrow during cementation of a tibial base plate significantly decreased axial pullout strength of a tibial baseplate in this laboratory model. All 1st generation baseplates exhibited debonding at the cement-implant interface.
Collapse
Affiliation(s)
- Blane C Kelly
- Department of Orthopaedic Surgery, Virginia Commonwealth University, Richmond, VA
| | - John R Owen
- Department of Orthopaedic Surgery, Virginia Commonwealth University, Richmond, VA
| | - Shalin C Shah
- Virginia Commonwealth University School of Medicine, Richmond, VA
| | - Aaron J Johnson
- Department of Orthopaedic Surgery, Virginia Commonwealth University, Richmond, VA
| | - Gregory J Golladay
- Department of Orthopaedic Surgery, Virginia Commonwealth University, Richmond, VA
| | - Stephen L Kates
- Department of Orthopaedic Surgery, Virginia Commonwealth University, Richmond, VA
| |
Collapse
|
29
|
Recommendations for Patients with High Return to Sports Expectations after TKA Remain Controversial. J Clin Med 2020; 10:jcm10010054. [PMID: 33375242 PMCID: PMC7796219 DOI: 10.3390/jcm10010054] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2020] [Revised: 12/18/2020] [Accepted: 12/22/2020] [Indexed: 11/17/2022] Open
Abstract
(1) Background: Improved surgical techniques and implants in total knee arthroplasty (TKA) have led to broader indications for surgical interventions of osteoarthritis of the knee. There is a growing young and active patient subgroup with high return to sports (RTS) expectations after TKA. The current lack of evidence regarding RTS capacity in this patient cohort, requires the consolidation of experts' opinions and experiences to address the special needs among these patients. The aim of this study was to assess current expert opinions in regard to preoperative patient assessment, surgical technique and decision-making and patient counseling for these patients. (2) Methods: We performed a survey among surgeons specialized in arthroplasty with a questionnaire designed to assess current recommendations, surgical techniques, and implant preferences as well as patient counseling in patients with high expectations for RTS after TKA. (3) Results: The majority of surgeons are in favor of return to low-impact sports after TKA within 3 to 6 months. Some even recommend return to high-impact sports. Despite improvement of surgical techniques and implants, we observed no clear preference for a single surgical technique or implant specification in active patients. (4) Conclusions: Current evidence for sports-associated complications after TKA is scarce. Despite a growing array of surgical techniques and implants, the available literature is still controversial with no single surgical technique or TKA design distinguishing itself clearly from others. Surgeons' recommendations are mostly based on their experience and training. Nonetheless, we observed growing faith in modern implants with some surgeons even recommending high-impact sports after TKA.
Collapse
|
30
|
Behrend H, Hochreiter B, Potocnik P, El Baz Y, Zdravkovic V, Tomazi T. No difference in radiolucent lines after TKA: a matched-pair analysis of the classic implant and its evolutional design. Knee Surg Sports Traumatol Arthrosc 2020; 28:3962-3968. [PMID: 32062683 DOI: 10.1007/s00167-020-05894-w] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/18/2019] [Accepted: 01/29/2020] [Indexed: 10/25/2022]
Abstract
PURPOSE Total knee arthroplasty (TKA) designs evolve continuously to improve patient outcomes. However, incidences of radiolucent lines (RLL) in the latest TKA system have recently been reported, raising concerns. The purpose of the current study was to compare radiographic outcomes of this new TKA implant to its predecessor design. METHODS A group of 100 patients undergoing TKA using the newer design (Attune) was matched by age and gender to 191 patients with the classic design (LCS). All patients underwent computer-navigated primary TKA by the same surgeon using the same technique. Radiographs were taken before discharge, and 2 and 12 months postoperatively. Radiographic analysis was performed independently by three assessors, using the Modern Knee Society Radiographic Evaluation System and Methodology (MKSRES). RESULTS At 12 months postoperatively, the incidence of RLL did not statistically differ between the two implants (14%, n = 14 Attune vs. 8% n = 17 LCS, n.s.). The posterior femoral flange was most commonly affected (12%; n = 12 Attune vs. 7.9%; n = 15 LCS, n.s.) followed by the anterior flange (1%; n = 1 Attune vs. 3.1%; n = 6 LCS, n.s.). The tibial baseplate was only affected in 1% (n = 1) of the Attune and 2.6% (n = 5) of the LCS (n.s.). CONCLUSION At 12 months follow-up we found no significant difference in RLL between the two implants. Both Attune and LCS TKA systems showed RLL predominantly at the posterior femoral flange. The reasons for the RLL remain a matter of speculation; however, shortcomings in surgical and cementing techniques seem to be more important than implant-related factors. LEVEL OF EVIDENCE III.
Collapse
Affiliation(s)
- Henrik Behrend
- Department of Orthopaedic Surgery and Traumatology, Kantonsspital St. Gallen, Rorschacherstrasse 95, 9007, St. Gallen, Switzerland.
| | - Bettina Hochreiter
- Department of Orthopaedic Surgery and Traumatology, Kantonsspital St. Gallen, Rorschacherstrasse 95, 9007, St. Gallen, Switzerland
| | - Primoz Potocnik
- Department of Orthopaedic Surgery and Traumatology, Kantonsspital St. Gallen, Rorschacherstrasse 95, 9007, St. Gallen, Switzerland
| | - Yassir El Baz
- Department of Radiology and Nuclear Medicine, Kantonsspital St. Gallen, 9007, St. Gallen, Switzerland
| | - Vilijam Zdravkovic
- Department of Orthopaedic Surgery and Traumatology, Kantonsspital St. Gallen, Rorschacherstrasse 95, 9007, St. Gallen, Switzerland
| | - Thiago Tomazi
- Department of Orthopaedic Surgery and Traumatology, Kantonsspital St. Gallen, Rorschacherstrasse 95, 9007, St. Gallen, Switzerland
| |
Collapse
|
31
|
Okazaki Y, Pujol N. The use of an asymmetrical tibial tray in TKA optimises tibial rotation when fitted to the posterior tibial plateau border. Knee Surg Sports Traumatol Arthrosc 2020; 28:3821-3826. [PMID: 32006074 DOI: 10.1007/s00167-020-05858-0] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/21/2019] [Accepted: 01/13/2020] [Indexed: 12/19/2022]
Abstract
PURPOSE The aim of this study was to evaluate the suitability of positioning an asymmetrical tibial tray relative to the posterior tibial edge and to analyse the relationship between the posterior fit and tibial rotation after computer-assisted total knee arthroplasty (TKA). It was hypothesised that an asymmetrical tray would adjust to the posterior border of the tibial plateau with proper tibial rotation. METHODS Ninety-three consecutive knees underwent total knee arthroplasty using a Persona fixed-bearing system (63 varus deformities and 30 valgus deformities) and a 3-month follow-up CT scan. An independent examiner measured different variables: the femoral angle between the clinical epicondylar axis and the posterior condylar line of the femoral component, the tibial angle between the posterior borders of the tibial tray and the tibial plateau, and the tibial rotation with respect to the femoral component. These measurements were also compared between varus and valgus subgroups. RESULTS For the varus and valgus subgroups, the mean postoperative femoral angle was 2.1º ± 1.2º and 2.5º ± 1.0º, respectively (n.s.). The mean posterior fitting angle of the tibial tray was 0.1º ± 2.4º and 1.4º ± 3.2º for the varus and valgus subgroups, respectively, with a significant difference between groups (p = 0.03). The tibial rotations with respect to the femoral component for the varus and valgus groups were 0.9º ± 3.3º and 2.2º ± 3.1º of external rotation, respectively (n.s.). CONCLUSIONS This study demonstrated that fitting an asymmetrical tibial tray to the posterior border of the tibial plateau could optimise tibial rotation. The posterior border was considered to be a reliable and easily identifiable landmark for proper tibial rotation and coverage during a primary TKA. LEVEL OF EVIDENCE IV.
Collapse
Affiliation(s)
- Yoshiki Okazaki
- Service d'Orthopédie Traumatologie, Department of Orthopedic Surgery, Centre Hospitalier de Versailles, Hôpital André-Mignot, 78150, Le Chesnay, France.,Department of Orthopaedic Surgery, Okayama University Graduate School, 2-5-1 Shikata-cho, Kitaku, Okayama, 700-8558, Japan
| | - Nicolas Pujol
- Service d'Orthopédie Traumatologie, Department of Orthopedic Surgery, Centre Hospitalier de Versailles, Hôpital André-Mignot, 78150, Le Chesnay, France.
| |
Collapse
|
32
|
Sharma M, Dhanjani B, Bashir J, Anshu AK. Clinico-Radiological and Functional Results of the Navigated Gradius (Gradually Reducing Radius) Knee Prosthesis at Short to Mid-Term Follow-Up. Indian J Orthop 2020; 55:62-68. [PMID: 34122756 PMCID: PMC8149567 DOI: 10.1007/s43465-020-00266-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/12/2020] [Accepted: 09/16/2020] [Indexed: 02/04/2023]
Abstract
BACKGROUND Navigated total knee replacements (TKR) have shown better knee function and quality of life. It also reduces revision rates. The aim of our study is to evaluate short to mid-term clinico-radiological and functional results, survival rate and complications of Gradius knee prosthesis implanted using computer navigation. METHODS We retrospectively reviewed 120 Gradius knee prosthesis, implanted in 68 patients (52 bilateral TKR and 16 unilateral TKR) and followed from Jan 2015 till Jan 2020. Pre-operative & post-operative radiographs, knee society scores (KSS), range of motion (ROM), deformity assessment and gait video recordings were done for all patients. RESULTS The mean follow-up was 3.8 years (minimum 2-5 years).The mean ROM was 2° (0-10) extension to 135° (128°-138°) flexion. The KSS pain score improved from mean of 38.3 (range 26-44) to 90.4 (mean 88-92). The KSS functional score improved from 36.2 (range 28-39) to 92.6 (range 86-94). All patients had excellent to good function during successive follow-ups. The coronal alignment improved from 8° varus to 0.3° varus. Sagittal alignment was corrected from 8° (4°-18°) preoperatively to 2° (0°-8°) postoperatively. CONCLUSION At mid-term our series outlines the better functional and radiological results of Gradius knee prosthesis using navigation as a tool. We recommend a prospective randomized controlled trials comparing navigated versus non-navigated for Gradius knee prosthesis with long-term follow-up.
Collapse
Affiliation(s)
- Mrinal Sharma
- grid.501415.40000 0004 1775 3981Department of Orthopedic Surgery, Asian Institute of Medical Sciences, Faridabad, Haryana India ,1203, Imperial Court Tower 2, Jaypee Greens Wish Town, Gautam Budh Nagar, Noida, Uttar Pradesh 201304 India
| | - Bharat Dhanjani
- grid.501415.40000 0004 1775 3981Department of Orthopedic Surgery, Asian Institute of Medical Sciences, Faridabad, Haryana India
| | - Jibran Bashir
- grid.501415.40000 0004 1775 3981Department of Orthopedic Surgery, Asian Institute of Medical Sciences, Faridabad, Haryana India
| | - Anshu Kumar Anshu
- grid.501415.40000 0004 1775 3981Department of Orthopedic Surgery, Asian Institute of Medical Sciences, Faridabad, Haryana India
| |
Collapse
|
33
|
Kaptein BL, den Hollander P, Thomassen B, Fiocco M, Nelissen RGHH. A randomized controlled trial comparing tibial migration of the ATTUNE cemented cruciate-retaining knee prosthesis with the PFC-sigma design. Bone Joint J 2020; 102-B:1158-1166. [PMID: 32862688 PMCID: PMC7468556 DOI: 10.1302/0301-620x.102b9.bjj-2020-0096.r1] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
AIMS The primary objective of this study was to compare migration of the cemented ATTUNE fixed bearing cruciate retaining tibial component with the cemented Press-Fit Condylar (PFC)-sigma fixed bearing cruciate retaining tibial component. The secondary objectives included comparing clinical and radiological outcomes and Patient Reported Outcome Measures (PROMs). METHODS A single blinded randomized, non-inferiority study was conducted including 74 patients. Radiostereometry examinations were made after weight bearing, but before hospital discharge, and at three, six, 12, and 24 months postoperatively. PROMS were collected preoperatively and at three, six, 12, and 24 months postoperatively. Radiographs for measuring radiolucencies were collected at two weeks and two years postoperatively. RESULTS The overall migration (mean maximum total point motion (MPTM)) at two years was comparable: mean 1.13 mm (95% confidence interval (CI), 0.97 to 1.30) for the ATTUNE and 1.16 mm (95% CI, 0.99 to 1.35) for the PFC-sigma. At two years, the mean backward tilting was -0.43° (95% CI, -0.65 to -0.21) for the ATTUNE and 0.08° (95% CI -0.16 to 0.31), for the PFC-sigma. Overall migration between the first and second postoperative year was negligible for both components. The clinical outcomes and PROMs improved compared with preoperative scores and were not different between groups. Radiolucencies at the implant-cement interface were mainly seen below the medial baseplate: 17% in the ATTUNE and 3% in the PFC-sigma at two weeks, and at two years 42% and 9% respectively (p = 0.001). CONCLUSION In the first two postoperative years the initial version of the ATTUNE tibial component was not inferior with respect to overall migration, although it showed relatively more backwards tilting and radiolucent lines at the implant-cement interface than the PFC-sigma. The version of the ATTUNE tibial component examined in this study has subsequently undergone modification by the manufacturer. Level of Evidence: 1 (randomized controlled clinical trial) Cite this article: Bone Joint J 2020;102-B(9):1158-1166.
Collapse
Affiliation(s)
- Bart L Kaptein
- Department of Orthopaedics, Leiden University Medical Center, Leiden, Netherlands
| | - Peter den Hollander
- Department of Orthopaedic Surgery, Haaglanden Medical Center, The Hague, Netherlands
| | - Bregje Thomassen
- Faculty Health, Nutrition and Sports, The Hague University of Applied Sciences, The Hague, Netherlands
| | - Martha Fiocco
- Mathematical Institute, Leiden University, Leiden, The Netherlands.,Medical Statistics, Department of Biomedical Data Sciences, Leiden University Medical Center, Leiden, Netherlands
| | - Rob G H H Nelissen
- Department of Orthopaedics, Leiden University Medical Center, Leiden, Netherlands
| |
Collapse
|
34
|
Jin QH, Lee WG, Song EK, Kim WJ, Jin C, Seon JK. No difference in the anteroposterior stability between the GRADIUS and multi-radius designs in total knee arthroplasty. Knee 2020; 27:1197-1204. [PMID: 32711882 DOI: 10.1016/j.knee.2020.05.019] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/10/2019] [Revised: 04/22/2020] [Accepted: 05/30/2020] [Indexed: 02/02/2023]
Abstract
BACKGROUND This retrospective study aimed to compare stability and clinical and radiological outcomes of total knee arthroplasty (TKA) for the GRADIUS and multi-radius femoral designs after minimum of two-year follow-up. METHODS A total of 142 patients who underwent TKA using ATTUNE posterior stabilized (PS) implants (68 patients, GRADIUS group) or Persona PS implants (74 patients, multi-radius group) for degenerative osteoarthritis were included. After an average of 2-year follow-up, the anteroposterior (AP) stability at 30°, 60°, and 90° was measured using KT 2000 device and compared between the two groups. The clinical outcome measurements included range of motion (ROM) of the knee, patient-reported outcomes and anterior knee pain (AKP). For the clinical evaluation of mid-flexion instability, pain was evaluated using the visual analog scale (VAS) score recorded during climbing up or going down stairs. The radiolucent lines on knee radiographs obtained at final follow-up were evaluated and compared between two groups. RESULTS The average AP stability at 30° knee flexion was 5.7 mm in the GRADIUS group and 5.9 mm in the multi-radius group; however, the difference was not significant. The AP stability at 60° and 90° knee flexion was also similar in both groups. There were no significant differences in the ROM, patient-reported outcomes at follow-up, incidence of AKP and VAS scores between the two groups. There were no differences in the incidence of radiolucency around the components between the two groups. CONCLUSION The GRADIUS design did not show any advantage with respect to the stability or clinical outcomes compared with the multi-radius design in TKA.
Collapse
Affiliation(s)
- Quan He Jin
- Chonnam National University Hwasun Hospital, Jeollanam-do, Republic of Korea
| | - Won-Gyun Lee
- Chonnam National University Hwasun Hospital, Jeollanam-do, Republic of Korea
| | - Eun-Kyoo Song
- Chonnam National University Hwasun Hospital, Jeollanam-do, Republic of Korea
| | - Woo-Jong Kim
- Chonnam National University Hwasun Hospital, Jeollanam-do, Republic of Korea
| | - Cheng Jin
- Department of Orthopaedic Surgery, Zhoushan Hospital, Zhoushan, Zhejiang, China
| | - Jong-Keun Seon
- Chonnam National University Hwasun Hospital, Jeollanam-do, Republic of Korea.
| |
Collapse
|
35
|
Use of National Joint Registries to Evaluate a New Knee Arthroplasty Design. J Arthroplasty 2020; 35:413-416. [PMID: 31629622 DOI: 10.1016/j.arth.2019.09.018] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/14/2019] [Revised: 08/24/2019] [Accepted: 09/12/2019] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND The introduction of new technology in joint replacement surgery requires close monitoring to identify early successes and failures. This monitoring can be effectively performed through the analysis of registry data and radiostereometric analysis studies. This study examined the revision rates of a contemporary knee system for total knee arthroplasty (TKA) using National Joint Replacement Registries. METHODS A review of the literature was performed to identify comparative studies and registry databases reporting the revision rates of a specific contemporary knee design between 2013 and 2018. The total number of TKA cases performed using this implant was recorded. The latest follow-up or duration of monitoring through a registry database was used to report implant survivorship. RESULTS There were 4 registry databases and 1 comparative study reporting the revision rates of the contemporary knee system. A total of 41,483 cases were identified with a follow-up range of 1.5-5.0 years. The all-cause revision rate ranged from 0.7% to 2.5% at latest follow-up. This was comparable to all-cause revision rates of other knee systems reported in the registries, ranging from 0.8% to 5.6% over similar follow-up periods. CONCLUSIONS Evaluation of data from multiple national joint registries demonstrated the revision rate for this contemporary knee system to be comparable to other TKA systems at latest follow-up. None of the registries have identified any concerning rates of revision compared to other devices at this length of follow-up. National Joint Registries are an important resource in evaluating the short-term, mid-term, and long-term results of new implant designs introduced to the market.
Collapse
|
36
|
Tibial Implant Fixation Behavior in Total Knee Arthroplasty: A Study With Five Different Bone Cements. J Arthroplasty 2020; 35:579-587. [PMID: 31653466 DOI: 10.1016/j.arth.2019.09.019] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/04/2019] [Revised: 08/15/2019] [Accepted: 09/13/2019] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND The objectives of this study are to (1) evaluate if there is a potential difference in cemented implant fixation strength between tibial components made out of cobalt-chromium (CrCoMo) and of a ceramic zirconium nitride (ZrN) multilayer coating and to (2) test their behavior with 5 different bone cements in a standardized in vitro model for testing of the implant-cement-bone interface conditions. We also analyzed (3) whether initial fixation strength is a function of timing of the cement apposition and component implantation by an early, mid-term, and late usage within the cement-specific processing window. METHODS An in vitro study using a synthetic polyurethane foam model was performed to investigate the implant fixation strength after cementation of tibial components by a push-out test. A total of 20 groups (n = 5 each) was used: Vega PS CrCoMo tibia and Vega PS ZrN tibia with the bone cements BonOs R, SmartSet HV, Cobalt HV, Palacos R, and Surgical Simplex P, respectively, using mid-term cement apposition. Three different cement apposition times-early, mid-term, and late usage-were tested with a total of 12 groups (n = 5 each) with the bone cements BonOs R and SmartSet HV. RESULTS There was no significant difference in implant-cement-bone fixation strength between CrCoMo and ZrN multilayer-coated Vega tibial trays tested with 5 different commonly used bone cements. CONCLUSION Apposition of bone cements and tibial tray implantation in the early to mid of the cement-specific processing window is beneficial in regard to interface fixation in TKA.
Collapse
|
37
|
Giaretta S, Berti M, Micheloni GM, Ceccato A, Marangoni F, Momoli A. Early experience with the ATTUNE Total Knee Replacement System. ACTA BIO-MEDICA : ATENEI PARMENSIS 2019; 90:98-103. [PMID: 31821292 PMCID: PMC7233713 DOI: 10.23750/abm.v90i12-s.8997] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/29/2019] [Accepted: 11/03/2019] [Indexed: 11/29/2022]
Abstract
BACKGROUND Modern TKA implants promise to improve functional outcomes, stability, patient satisfaction and operating room efficiency. The purpose of this retrospective study is to evaluate our short-term clinical and radiological results and survival using the ATTUNE Total Knee Replacement System. METHODS The authors reviewed 228 primary cemented TKAs using ATTUNE Total Knee Replacement System which were implanted between 2014 and 2018 concerning short-term clinical and radiographical outcomes and survival. Clinical evaluation was performed using the Knee injury Osteoarthritis Outcome Score (KOOS), the Oxford Score and a Numeric Rating Scale (NRS) for pain. Radiographic analysis was performed using the Modern Knee Society Score Evaluation System. RESULTS The means of the clinical results as measured with KOOS score were Pain 82,7, Symptoms 79, ADL 78,3, Sport and recreation 51,8 and QOL 78,6. The mean Oxford score was 35 and NRS 2. The mean ROM was 113,4 (SD 9,4 range 90-130). Radiographically mean mechanical axis was 1,97° of Varus and radiolucent lines were detected in 43 knees (22,4%). The survival rate is 98.4% at 2 years and 97.4% at 5 years. CONCLUSION At short-term follow-up the ATTUNE Knee Replacement System provide excellent clinical and radiographical outcomes and good results regarding revision rate. Due to high incidence of radiolucent lines, those patients should be closely monitored even though they show no clinical evidence for loosening.
Collapse
Affiliation(s)
- Stefano Giaretta
- Orthopedic and Traumatology Unit, San Bortolo Hospital, Vicenza, Italy.
| | | | | | | | | | | |
Collapse
|
38
|
Gu S, Kuriyama S, Nakamura S, Nishitani K, Ito H, Matsuda S. Underhang of the tibial component increases tibial bone resorption after total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 2019; 27:1270-1279. [PMID: 30470851 DOI: 10.1007/s00167-018-5309-4] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/10/2018] [Accepted: 11/15/2018] [Indexed: 10/27/2022]
Abstract
PURPOSE One of the causes of aseptic loosening is marked tibial bone resorption (TR) at the tibial bone-component interface after total knee arthroplasty (TKA). It was hypothesized that insufficient coverage of the tibial component and improper cementing technique would cause increased TR after cemented TKA. METHODS One hundred thirty-four primary TKAs in 107 patients with varus osteoarthritis were included in this study. The relationships between the TRs at 2 years after TKA and the tibial component underhang (TUH), the thickness of the cement mantle around the keel, and clinical parameters were evaluated. RESULTS The widths of TRs on anteroposterior radiographs were significantly larger on the medial side than on the lateral side (p = 0.001), whereas the difference between the anterior and posterior sides on lateral radiographs was relatively small. Multiple regression analyses showed that medial TR was positively related to medial TUH (p = 0.006), and lateral TR was positively related to a thicker distal cement mantle (p = 0.027). On the lateral view, stepwise selection indicated that postoperative knee flexion angle was the most significant risk factor (p = 0.005) for anterior TR, and posterior TUH was the strongest predictor (p = 0.001) of posterior TR. CONCLUSIONS To avert postoperative progressive TR, surgeons should perfectly fit a suitably sized tibial component to the medial edge of the tibia. Also, care should be taken to avoid an excessive cement mantle at the distal portion of the keel during TKA. LEVEL OF EVIDENCE IV.
Collapse
Affiliation(s)
- ShiZhong Gu
- Department of Orthopaedic Surgery, Graduate School of Medicine, Kyoto University, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto, 606-8507, Japan.,Department of Orthopaedic Surgery, Sports Medicine and Joint Surgery, The First Hospital of China Medical University, Shenyang, Liaoning, China
| | - Shinichi Kuriyama
- Department of Orthopaedic Surgery, Graduate School of Medicine, Kyoto University, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto, 606-8507, Japan.
| | - Shinichiro Nakamura
- Department of Orthopaedic Surgery, Graduate School of Medicine, Kyoto University, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto, 606-8507, Japan
| | - Kohei Nishitani
- Department of Orthopaedic Surgery, Graduate School of Medicine, Kyoto University, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto, 606-8507, Japan
| | - Hiromu Ito
- Department of Orthopaedic Surgery, Graduate School of Medicine, Kyoto University, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto, 606-8507, Japan
| | - Shuichi Matsuda
- Department of Orthopaedic Surgery, Graduate School of Medicine, Kyoto University, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto, 606-8507, Japan
| |
Collapse
|