Du H, Sui X, Zhao R, Wang J, Ming Y, Piao S, Wang J, Ma Z, Wang Y, Song L, Song W. A comparative analysis of deep learning and hybrid iterative reconstruction algorithms with contrast-enhancement-boost post-processing on the image quality of indirect computed tomography venography of the lower extremities. BMC Med Imaging 2024; 24:163. [PMID: 38956583 PMCID: PMC11218076 DOI: 10.1186/s12880-024-01342-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2024] [Accepted: 06/19/2024] [Indexed: 07/04/2024] Open
Abstract
PURPOSE To examine whether there is a significant difference in image quality between the deep learning reconstruction (DLR [AiCE, Advanced Intelligent Clear-IQ Engine]) and hybrid iterative reconstruction (HIR [AIDR 3D, adaptive iterative dose reduction three dimensional]) algorithms on the conventional enhanced and CE-boost (contrast-enhancement-boost) images of indirect computed tomography venography (CTV) of lower extremities. MATERIALS AND METHODS In this retrospective study, seventy patients who underwent CTV from June 2021 to October 2022 to assess deep vein thrombosis and varicose veins were included. Unenhanced and enhanced images were reconstructed for AIDR 3D and AiCE, AIDR 3D-boost and AiCE-boost images were obtained using subtraction software. Objective and subjective image qualities were assessed, and radiation doses were recorded. RESULTS The CT values of the inferior vena cava (IVC), femoral vein ( FV), and popliteal vein (PV) in the CE-boost images were approximately 1.3 (1.31-1.36) times higher than in those of the enhanced images. There were no significant differences in mean CT values of IVC, FV, and PV between AIDR 3D and AiCE, AIDR 3D-boost and AiCE-boost images. Noise in AiCE, AiCE-boost images was significantly lower than in AIDR 3D and AIDR 3D-boost images ( P < 0.05). The SNR (signal-to-noise ratio), CNR (contrast-to-noise ratio), and subjective scores of AiCE-boost images were the highest among 4 groups, surpassing AiCE, AIDR 3D, and AIDR 3D-boost images (all P < 0.05). CONCLUSION In indirect CTV of the lower extremities images, DLR with the CE-boost technique could decrease the image noise and improve the CT values, SNR, CNR, and subjective image scores. AiCE-boost images received the highest subjective image quality score and were more readily accepted by radiologists.
Collapse
Affiliation(s)
- Huayang Du
- Department of Radiology, Peking Union Medical College Hospital (PUMCH), Chinese Academy of Medical Sciences & Peking Union Medical College (CAMS & PUMC), No.1 Shuaifuyuan Wangfujing Dongcheng District, Beijing, 100730, China
| | - Xin Sui
- Department of Radiology, Peking Union Medical College Hospital (PUMCH), Chinese Academy of Medical Sciences & Peking Union Medical College (CAMS & PUMC), No.1 Shuaifuyuan Wangfujing Dongcheng District, Beijing, 100730, China.
| | - Ruijie Zhao
- Department of Radiology, Peking Union Medical College Hospital (PUMCH), Chinese Academy of Medical Sciences & Peking Union Medical College (CAMS & PUMC), No.1 Shuaifuyuan Wangfujing Dongcheng District, Beijing, 100730, China
| | - Jiaru Wang
- Department of Radiology, Peking Union Medical College Hospital (PUMCH), Chinese Academy of Medical Sciences & Peking Union Medical College (CAMS & PUMC), No.1 Shuaifuyuan Wangfujing Dongcheng District, Beijing, 100730, China
| | - Ying Ming
- Department of Radiology, Peking Union Medical College Hospital (PUMCH), Chinese Academy of Medical Sciences & Peking Union Medical College (CAMS & PUMC), No.1 Shuaifuyuan Wangfujing Dongcheng District, Beijing, 100730, China
| | - Sirong Piao
- Department of Radiology, Peking Union Medical College Hospital (PUMCH), Chinese Academy of Medical Sciences & Peking Union Medical College (CAMS & PUMC), No.1 Shuaifuyuan Wangfujing Dongcheng District, Beijing, 100730, China
| | - Jinhua Wang
- Department of Radiology, Peking Union Medical College Hospital (PUMCH), Chinese Academy of Medical Sciences & Peking Union Medical College (CAMS & PUMC), No.1 Shuaifuyuan Wangfujing Dongcheng District, Beijing, 100730, China
| | - Zhuangfei Ma
- Canon Medical Systems (China), No.3, Xinyuan South Road, Chaoyang District, Beijing, 100027, China
| | - Yun Wang
- Department of Radiology, Peking Union Medical College Hospital (PUMCH), Chinese Academy of Medical Sciences & Peking Union Medical College (CAMS & PUMC), No.1 Shuaifuyuan Wangfujing Dongcheng District, Beijing, 100730, China
| | - Lan Song
- Department of Radiology, Peking Union Medical College Hospital (PUMCH), Chinese Academy of Medical Sciences & Peking Union Medical College (CAMS & PUMC), No.1 Shuaifuyuan Wangfujing Dongcheng District, Beijing, 100730, China
| | - Wei Song
- Department of Radiology, Peking Union Medical College Hospital (PUMCH), Chinese Academy of Medical Sciences & Peking Union Medical College (CAMS & PUMC), No.1 Shuaifuyuan Wangfujing Dongcheng District, Beijing, 100730, China.
| |
Collapse
|
2
|
Wu H, Wang J, Zhou M, Wang Y, Cui C, Zhou C, Chen X, Wang Z. Application of bolus tracking: The effect of ROI positions on the images quality of cervicocerebral CT angiography. Heliyon 2024; 10:e29260. [PMID: 38617933 PMCID: PMC11015132 DOI: 10.1016/j.heliyon.2024.e29260] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2023] [Revised: 03/28/2024] [Accepted: 04/03/2024] [Indexed: 04/16/2024] Open
Abstract
Background Cervicocerebral CT angiography (CTA) using the bolus tracking technique has been widely used for the assessment of cerebrovascular diseases. Regions of interest (ROI) can be placed in the descending aorta, ascending aorta, and the aortic arch. However, no study has compared the arteries and veins display when when the region of interest (ROI) is placed at different sites. In this study, we showed the impact of ROI positions on the image quality of cervicocerebral CTA. Methods Two hundred and seventy patients who underwent cervicocerebral CTA with bolus tracking technique were randomly divided into three groups based on the position of the ROI placement: ascending aorta (Group 1, n = 90), aortic arch (Group 2, n = 90), and descending aorta (Group 3, n = 90). The scanning parameters and contrast agent injection protocols were consistent across all groups. Three observers independently assessed the objective image quality, while two observers jointly assessed the subjective image quality using a grade scale: poor (grade 1), average (grade 2), good (grade 3), and excellent (grade 4). The differences in intravascular CT values, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), AVCR (arterial venous contrast ratio), and subjective image quality scores were compared among the three groups. Results The CT values of the intracranial veins (superior sagittal sinus, ethmoid sinus and great cerebral vein) in group 1 were significantly lower than those in group 3 (p < 0.001). However, no significant differences were observed in CT values, SNR and CNR in the internal carotid artery and middle cerebral artery among the three groups. The proportion of images with grade 4 was significantly higher in group 1 than group 2 and 3 (41.1% vs 15.6% and 13.3%, p < 0.001). The proportion of images with grade 1 was significantly lower in group 1 than group 2 and 3 (1.1% vs 6.6% and 17.8%, p < 0.001). Conclusion The ROI positions for cervicocerebral CTA did not affect the arterial image quality, but venous structures imaging was affected when the ROI was placed in the ascending aorta.
Collapse
Affiliation(s)
- Huiming Wu
- Department of Radiology, The Affiliated Hospital of Nanjing University of Chinese Medicine, 155 Hanzhong road, Nanjing, 210029, China
| | - Jianhua Wang
- Department of Radiology, The Affiliated Hospital of Nanjing University of Chinese Medicine, 155 Hanzhong road, Nanjing, 210029, China
| | - Maodong Zhou
- Department of Radiology, The Affiliated Hospital of Nanjing University of Chinese Medicine, 155 Hanzhong road, Nanjing, 210029, China
| | - Yajie Wang
- Department of Radiology, The Affiliated Hospital of Nanjing University of Chinese Medicine, 155 Hanzhong road, Nanjing, 210029, China
| | - Can Cui
- Department of Radiology, The Affiliated Hospital of Nanjing University of Chinese Medicine, 155 Hanzhong road, Nanjing, 210029, China
| | - Changsheng Zhou
- Department of Radiology, Jinling Hospital Nanjing University, 305 Zhongshan East road, Nanjing, 210029, China
| | - Xiao Chen
- Department of Radiology, The Affiliated Hospital of Nanjing University of Chinese Medicine, 155 Hanzhong road, Nanjing, 210029, China
| | - Zhongqiu Wang
- Department of Radiology, The Affiliated Hospital of Nanjing University of Chinese Medicine, 155 Hanzhong road, Nanjing, 210029, China
| |
Collapse
|
3
|
Du B, Zhang W, Shao X, An J, Ma H, Zhao X, Xu L, An D, Tian Y, Dong Y, Niu H. "Triple-low" radiation dose bronchial artery CT angiography before bronchial artery embolisation: a feasibility study. Clin Radiol 2023; 78:e1017-e1022. [PMID: 37813755 DOI: 10.1016/j.crad.2023.09.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2023] [Revised: 09/01/2023] [Accepted: 09/12/2023] [Indexed: 10/11/2023]
Abstract
AIM To explore the feasibility of a "triple-low" dose (low tube voltage, low tube current, and low contrast agent volume) bronchial artery computed tomography (CT) angiography (CTA) to replace routine dose bronchial artery CTA before bronchial artery embolisation (BAE). MATERIALS AND METHODS CTA was obtained from 60 patients with body mass index (BMI) < 30 kg/m2 using a 256 multi-section iCT system, and they were divided into two groups: (1) group A: 100 kVp, 100 mAs, 50 ml contrast medium (CM); (2) group B: 120 kVp, automatic tube current modulation (ACTM), 80 ml CM. CT attenuation of the thoracic aorta, image noise, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated, and subjective image quality scores and traceability scores assessed. The effective radiation dose was calculated. RESULTS The radiation dose was reduced by 79.7% in group A compared to group B (p<0.05). The CT attenuation of the thoracic aorta was increased by approximately 13% in group A compared to group B (p<0.05). Higher image noise, lower SNR, and CNR were obtained in group A compared to group B (all p<0.05). Both subjective image quality scores and traceability scores did not differ between groups A and B (both p>0.05). CONCLUSION It is feasible to use the "triple-low" dose CTA protocol for patients with a body mass index (BMI) < 30 kg/m2. The radiation dose was reduced by 79.7%, and the dose of contrast medium was reduced by 37.5% to ensure the diagnostic value.
Collapse
Affiliation(s)
- B Du
- Department of Radiology, Hebei Medical University, No. 361 Zhongshan East Road, Shijiazhuang, 050011, Hebei, China
| | - W Zhang
- Chengde Medical University, Anyuan Road, Chengde, 067000, Hebei, China
| | - X Shao
- Department of Radiology, Hebei Medical University, No. 361 Zhongshan East Road, Shijiazhuang, 050011, Hebei, China
| | - J An
- Department of Interventional Treatment, First Hospital of Qinhuangdao, No. 258 Wenhua Road, Qinhuangdao, 066099, Hebei, China
| | - H Ma
- Chengde Medical University, Anyuan Road, Chengde, 067000, Hebei, China
| | - X Zhao
- Department of Radiology, Hebei Medical University, No. 361 Zhongshan East Road, Shijiazhuang, 050011, Hebei, China
| | - L Xu
- Department of Radiology, Hebei Medical University, No. 361 Zhongshan East Road, Shijiazhuang, 050011, Hebei, China
| | - D An
- Department of Interventional Treatment, First Hospital of Qinhuangdao, No. 258 Wenhua Road, Qinhuangdao, 066099, Hebei, China
| | - Y Tian
- Department of Interventional Treatment, First Hospital of Qinhuangdao, No. 258 Wenhua Road, Qinhuangdao, 066099, Hebei, China
| | - Y Dong
- Department of Interventional Treatment, First Hospital of Qinhuangdao, No. 258 Wenhua Road, Qinhuangdao, 066099, Hebei, China
| | - H Niu
- Department of Interventional Treatment, First Hospital of Qinhuangdao, No. 258 Wenhua Road, Qinhuangdao, 066099, Hebei, China.
| |
Collapse
|
4
|
Dieckmeyer M, Sollmann N, Kupfer K, Löffler MT, Paprottka KJ, Kirschke JS, Baum T. Computed Tomography of the Head : A Systematic Review on Acquisition and Reconstruction Techniques to Reduce Radiation Dose. Clin Neuroradiol 2023; 33:591-610. [PMID: 36862232 PMCID: PMC10449676 DOI: 10.1007/s00062-023-01271-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2022] [Accepted: 01/24/2023] [Indexed: 03/03/2023]
Abstract
In 1971, the first computed tomography (CT) scan was performed on a patient's brain. Clinical CT systems were introduced in 1974 and dedicated to head imaging only. New technological developments, broader availability, and the clinical success of CT led to a steady growth in examination numbers. Most frequent indications for non-contrast CT (NCCT) of the head include the assessment of ischemia and stroke, intracranial hemorrhage and trauma, while CT angiography (CTA) has become the standard for first-line cerebrovascular evaluation; however, resulting improvements in patient management and clinical outcomes come at the cost of radiation exposure, increasing the risk for secondary morbidity. Therefore, radiation dose optimization should always be part of technical advancements in CT imaging but how can the dose be optimized? What dose reduction can be achieved without compromising diagnostic value, and what is the potential of the upcoming technologies artificial intelligence and photon counting CT? In this article, we look for answers to these questions by reviewing dose reduction techniques with respect to the major clinical indications of NCCT and CTA of the head, including a brief perspective on what to expect from current and future developments in CT technology with respect to radiation dose optimization.
Collapse
Affiliation(s)
- Michael Dieckmeyer
- Department of Diagnostic, Interventional and Pediatric Radiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
- Department of Diagnostic and Interventional Neuroradiology, School of Medicine, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
| | - Nico Sollmann
- Department of Diagnostic and Interventional Neuroradiology, School of Medicine, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
- TUM-Neuroimaging Center, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
- Department of Diagnostic and Interventional Radiology, University Hospital Ulm, Ulm, Germany
| | - Karina Kupfer
- Department of Diagnostic and Interventional Neuroradiology, School of Medicine, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
| | - Maximilian T. Löffler
- Department of Diagnostic and Interventional Neuroradiology, School of Medicine, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
- Department of Diagnostic and Interventional Radiology, University Medical Center Freiburg, Freiburg im Breisgau, Germany
| | - Karolin J. Paprottka
- Department of Diagnostic and Interventional Neuroradiology, School of Medicine, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
| | - Jan S. Kirschke
- Department of Diagnostic and Interventional Neuroradiology, School of Medicine, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
- TUM-Neuroimaging Center, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
| | - Thomas Baum
- Department of Diagnostic and Interventional Neuroradiology, School of Medicine, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
| |
Collapse
|
5
|
Gu G, Zhang X, Shen J, Gulidanna S, Gao Q, Shao J, Liu B, Zhang B, Zheng Y. Comparison of Contrast-Enhanced Ultrasonography to Color Doppler Ultrasound in Evaluation of Carotid Body Tumors. Front Oncol 2022; 12:872890. [PMID: 35480104 PMCID: PMC9035876 DOI: 10.3389/fonc.2022.872890] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2022] [Accepted: 03/15/2022] [Indexed: 11/13/2022] Open
Abstract
Objective The objectives of this study were to prospectively 1) explore the characteristics and enhanced patterns of carotid body tumors (CBTs) at color Doppler ultrasound (CDU) and contrast-enhanced ultrasonography (CEUS) qualitatively and quantitatively and 2) compare CDU and CEUS for their morphology and vascularity signature. Methods CDU and CEUS with Sonovue® were used to evaluate 25 CBT lesions. The comparison between these ultrasonic modalities included the size, Shamblin type, vascularity, and feeding vessels of the lesion areas. The time–intensity curve (TIC) analysis was used to obtain the dynamics of the contrast-enhancement features of CBTs. Results The TIC analysis presented a fast wash-in [wash-in time: 3.00 ± 1.10 s, mean ± SD] and slow wash-out [wash-out time: 58.79 ± 24.21 s, mean ± SD] pattern in the CBT lesions, with a high area under the curve (AUC) of 669.68 ± 143.46 mm2 (mean ± SD). In comparison with CDU, CEUS was superior in identifying Shamblin type I or III CBT lesions (χ2 = 17.389, p=0.002). It detected a significant difference in the AUC between moderate and marked vascularity groups (563.33 ± 102.63 vs. 707.22 ± 138.81, t=-2.311, p=0.031.), while CDU observed no significant difference between these two groups. Although CDU was more sensitive than CEUS in detecting feeding vessels (100% vs. 88%), CEUS better visualized the origins of feeding vessels (χ2 = 9.162, p=0.010). Conclusion CEUS can better investigate the Shamblin type and vascularity of CBT lesions than CDU. CBTs displayed a fast wash-in, slow wash-out pattern with high AUC in the TIC analysis in the CEUS mode. CDU is more sensitive in detecting feeding vessels than CEUS, while CEUS can better visualize the origins of feeding vessels.
Collapse
Affiliation(s)
- Guangchao Gu
- Department of Vascular Surgery, Peking Union Medical College Hospital, Beijing, China
| | - Xiaoyan Zhang
- Department of Diagnostic Ultrasound, Peking Union Medical College Hospital, Beijing, China
| | - Junyue Shen
- Department of Vascular Surgery, Peking Union Medical College Hospital, Beijing, China
- School of Medicine, Tsinghua University, Beijing, China
- Key Laboratory of Carcinogenesis and Translational Research (Ministry of Education/Beijing), Department of Radiation Oncology, Peking University Cancer Hospital & Institute, Beijing, China
| | - Shayan Gulidanna
- Department of Vascular Surgery, Peking Union Medical College Hospital, Beijing, China
- School of Medicine, Tsinghua University, Beijing, China
| | - Qiong Gao
- Department of Diagnostic Ultrasound, Peking Union Medical College Hospital, Beijing, China
| | - Jiang Shao
- Department of Vascular Surgery, Peking Union Medical College Hospital, Beijing, China
| | - Bao Liu
- Department of Vascular Surgery, Peking Union Medical College Hospital, Beijing, China
| | - Bo Zhang
- Department of Diagnostic Ultrasound, Peking Union Medical College Hospital, Beijing, China
- Department of Ultrasound, China-Japan Friendship Hospital, Beijing, China
- *Correspondence: Yuehong Zheng, ; Bo Zhang,
| | - Yuehong Zheng
- Department of Vascular Surgery, Peking Union Medical College Hospital, Beijing, China
- State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Chinese Academy of Medical Science and Peking Union Medical College, Beijing, China
- *Correspondence: Yuehong Zheng, ; Bo Zhang,
| |
Collapse
|
6
|
Wang Y, Chen Y, Liu P, Lv W, Wu J, Wei M, Shi D, Wu X, Liu W, Tao X, Hu H, Ma X, Yang X, Xue H, Jin Z. Clinical effectiveness of contrast medium injection protocols for 80-kV coronary and craniocervical CT angiography-a prospective multicenter observational study. Eur Radiol 2022; 32:3808-3818. [PMID: 35103828 DOI: 10.1007/s00330-021-08505-5] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2021] [Revised: 10/22/2021] [Accepted: 12/04/2021] [Indexed: 11/26/2022]
Abstract
BACKGROUND AND OBJECTIVE Decreasing X-ray tube voltage is an effective way to reduce radiation and contrast dose, especially in non-obese patients. The current study focuses on CTA in non-obese patients to evaluate image quality and feasibility of 80-kV acquisition protocols with varying iodine delivery rates (IDR) and contrast concentrations in routine clinical practice. METHODS A prospective observational study in patients ≥ 18 years and ≤ 90 kg referred for coronary or craniocervical CTA at 10 centers in China (ClinicalTrials.gov: NCT02840903). Patients were divided into four groups: a standard 100-kV protocol (370 mgI/ml, IDR 1.48 gI/s), and three 80-kV protocols (370 mgI/ml, IDR 1.2 gI/s; 300 mgI/ml, IDR 1.2 gI/s; 300 mgI/ml, IDR 0.96gI/s). The primary outcome was contrast opacification of target vascular segments. Secondary outcomes were image quality (contrast-to-noise ratio, signal-to-noise ratio, visual image quality, and diagnostic confidence assessment), radiation, and iodine dose. RESULTS From July 2016 to July 2017, 1213 patients were enrolled: 614 coronary and 599 craniocervical CTA. The mean contrast opacification was ≥ 300 HU for 80-kV 1.2 gI/s IDR scanned segments; IDR 0.96 gI/s led to lower opacification. Image quality and diagnostic confidence were fair to excellent (≥ 98% of images), despite lower contrast-to-noise ratios and signal-to-noise ratios in 80-kV images. Compared to the standard protocol, 80-kV protocols led to 44-52% radiation dose reductions (p < 0.001) and 19% iodine dose reductions (p < 0.001). CONCLUSION Eighty-kilovolt 1.2 gI/s IDR protocols can be recommended for coronary and craniocervical CTA in non-obese patients, reducing radiation and iodine dose without compromising image quality. KEY POINTS • Using low-voltage scanning CTA protocols, in which tube voltage and iodine delivery rate are reduced proportionally (voltage: 80 kV, IDR: 1.2 gI/s), reduces radiation and contrast dose without compromising image quality in routine clinical practice. • Reducing iodine delivery rate beyond direct proportionality to tube voltage is not beneficial.
Collapse
Affiliation(s)
- Yining Wang
- Peking Union Medical College Hospital, Shuaifuyan Wangfujing District, Beijing, 100730, China
| | - Yu Chen
- Peking Union Medical College Hospital, Shuaifuyan Wangfujing District, Beijing, 100730, China
| | - Peijun Liu
- Peking Union Medical College Hospital, Shuaifuyan Wangfujing District, Beijing, 100730, China
| | - Wan Lv
- The First People's Hospital of Yulin, # 495, JiaoYu Central Road, Yulin, 537000, Guangxi, China
| | - Jianlin Wu
- Affiliated Zhongshan Hospital of Dalian University, # 6, Jiefang Road Zhongshan District, Dalian, 116001, Liaoning, China
| | - Mengqi Wei
- The First Affiliated Hospital of Air Force Medical University, # 15 Changle West Road, Xian, 710032, Shanxi, China
| | - Dapeng Shi
- Henan Provincial People's Hospital, # 7, Weiwu Road, Zhengzhou, 450000, Henan, China
| | - Xianheng Wu
- The Second People's Hospital of Shantou, # 28, Waimalu Road, Shantou, 515031, Guangdong, China
| | - Wenya Liu
- The First Affiliated Hospital of Xinjiang Medical University, # 137, Liyushan South Road, Urumqi, 830054, Xinjiang, China
| | - Xiaofeng Tao
- Shanghai Ninth People's Hospital, Shanghai Jiaotong University School of Medicine, # 639, Zaoju Road, Shanghai, 200011, China
| | - Hongjie Hu
- Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, 3 Qinchun East Road, Hangzhou, 310016, Zhejiang, China
| | - Xiangxing Ma
- Qilu Hospital of Shandong University (Qingdao), North District, # 758, Hefei Road, Qingdao, 266035, Shandong, China
| | - Xiaozheng Yang
- Medical Affairs, Bayer Healthcare Co. Ltd, Dongshanhuan Central Road, Beijing, 100010, China
| | - Huadan Xue
- Peking Union Medical College Hospital, Shuaifuyan Wangfujing District, Beijing, 100730, China
| | - Zhengyu Jin
- Peking Union Medical College Hospital, Shuaifuyan Wangfujing District, Beijing, 100730, China.
| |
Collapse
|
7
|
Chen PA, Chen CW, Chou CC, Fu JH, Wang PC, Hsu SH, Lai PH. Impact of 80 kVp with iterative reconstruction algorithm and low-dose contrast medium on the image quality of craniocervical CT angiography. Clin Imaging 2020; 68:124-130. [PMID: 32592973 DOI: 10.1016/j.clinimag.2020.05.024] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2020] [Revised: 05/08/2020] [Accepted: 05/27/2020] [Indexed: 11/19/2022]
Abstract
PURPOSE To assess the image quality of 80-kVp craniocervical CT angiography (CCCTA) protocol combined with adaptive statistical iterative reconstruction-V (ASIR-V) and low-dose contrast medium (CM). METHODS A total of 119 patients were randomly divided into three groups. For group A, 120-kVp protocol was followed with 60 ml CM and filtered back projection; for group B, 80-kVp protocol with 60 ml CM and ASIR-V; and for group C, 80-kVp protocol with 45 ml CM and ASIR-V. Both subjective and objective image quality and radiation doses were evaluated. RESULTS Arterial attenuation, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of the head, neck, and shoulder regions were significantly higher in groups B and C compared with group A. Group C yielded significantly better subjective image quality than that observed in groups A and B (both p < .05). As compared with group A, effective radiation dose and the iodine load of group C were reduced by 51.4% and 25%, respectively. CONCLUSIONS The CCCTA protocol with 80 kVp, ASIR-V, and 45 ml of CM injected at 3 ml/s significantly reduced the radiation dose, iodine load, and iodine delivery rate while providing better subjective and objective image quality, including higher arterial enhancement and a higher SNR and CNR compared with the 120-kVp protocol.
Collapse
Affiliation(s)
- Po-An Chen
- Department of Radiology, Kaohsiung Veterans General Hospital, No. 386, Ta-Chung 1st Road, Kaohsiung 81362, Taiwan; Faculty of Medicine, School of Medicine, National Yang Ming University, Taipei, Taiwan; Institute of Clinical Medicine, National Yang Ming University, Taipei, Taiwan
| | - Chih-Wei Chen
- Department of Radiology, Kaohsiung Veterans General Hospital, No. 386, Ta-Chung 1st Road, Kaohsiung 81362, Taiwan; Faculty of Medicine, School of Medicine, National Yang Ming University, Taipei, Taiwan; Institute of Clinical Medicine, National Yang Ming University, Taipei, Taiwan
| | - Chiung-Chen Chou
- Department of Radiology, Kaohsiung Veterans General Hospital, No. 386, Ta-Chung 1st Road, Kaohsiung 81362, Taiwan
| | - Jui-Hsun Fu
- Department of Radiology, Kaohsiung Veterans General Hospital, No. 386, Ta-Chung 1st Road, Kaohsiung 81362, Taiwan; Faculty of Medicine, School of Medicine, National Yang Ming University, Taipei, Taiwan; Institute of Clinical Medicine, National Yang Ming University, Taipei, Taiwan
| | - Po-Chin Wang
- Department of Radiology, Kaohsiung Veterans General Hospital, No. 386, Ta-Chung 1st Road, Kaohsiung 81362, Taiwan; Faculty of Medicine, School of Medicine, National Yang Ming University, Taipei, Taiwan; Institute of Clinical Medicine, National Yang Ming University, Taipei, Taiwan
| | - Shuo-Hsiu Hsu
- Department of Radiology, Kaohsiung Veterans General Hospital, No. 386, Ta-Chung 1st Road, Kaohsiung 81362, Taiwan
| | - Ping-Hong Lai
- Department of Radiology, Kaohsiung Veterans General Hospital, No. 386, Ta-Chung 1st Road, Kaohsiung 81362, Taiwan; Faculty of Medicine, School of Medicine, National Yang Ming University, Taipei, Taiwan; Institute of Clinical Medicine, National Yang Ming University, Taipei, Taiwan.
| |
Collapse
|
8
|
Bathla G, Priya S, Samaniego E, Deo SK, Fain NH, Soni N, Ward C, Derdeyn CP. Cerebral computed tomographic angiography using third-generation reconstruction algorithm provides improved image quality with lower contrast and radiation dose. Neuroradiology 2020; 62:965-970. [PMID: 32277245 DOI: 10.1007/s00234-020-02406-y] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2019] [Accepted: 03/13/2020] [Indexed: 02/03/2023]
Abstract
PURPOSE We hypothesized that cerebral CT angiogram performed using third-generation reconstruction algorithm and lower contrast dose-low-kVp technique (LD-CTA) will provide better image quality when compared with regular contrast dose CTA at 120 kVp using a sinogram-affirmed iterative reconstruction algorithm (ND-CTA). METHODS Retrospective imaging review of 100 consecutive patients (50 each in LD- and ND-CTA groups). Two readers independently assessed the subjective image quality across multiple vascular segments on a Likert-like scale. Differences in contrast dose, CT dose index (CTDI), and dose length product (DLP) were compared using Mann-Whitney U test. Fisher's exact test was used to compare subjective image quality. Similarly, contrast- and signal-to-noise ratios (CNR and SNR) were compared in the mid-M1 MCA vessels bilaterally and the mid-basilar artery using Mann-Whitney U test. Interclass correlation coefficient (ICC) was calculated for the SNR/CNR values. RESULTS Both observers showed excellent correlation in subjective image quality (mean percentage agreement of 95.2% for group 1 versus 89.2% for group 2). LD-CTA group showed better SNR and CNR (p < 0.0001) for both MCA vessels and the mid-basilar artery. Interclass correlation coefficient showed moderate correlation (0.51-0.63) between readers. LD-CTA group also used lower contrast (49 cc versus 97 cc in ND-CTA) and had lower radiation exposure (DLP/CTDI for both groups 268.3/80.7 vs 519.5/36.08, both < 0.0001). CONCLUSION Next-generation reconstruction algorithm and low-kV scanning significantly improved image quality on cerebral CTA images despite lower contrast dose and, in addition, have lower radiation exposure.
Collapse
Affiliation(s)
- Girish Bathla
- Department of Radiology, University of Iowa Hospitals and Clinics, 200 Hawkins Drive, Iowa City, IA, 52242, USA.
| | - Sarv Priya
- Department of Radiology, University of Iowa Hospitals and Clinics, 200 Hawkins Drive, Iowa City, IA, 52242, USA
| | - Edgar Samaniego
- Department of Radiology, University of Iowa Hospitals and Clinics, 200 Hawkins Drive, Iowa City, IA, 52242, USA
- Department of Neurology, University of Iowa Hospitals and Clinics, Iowa City, IA, USA
| | - Simmi K Deo
- Department of Radiology, University of Iowa Hospitals and Clinics, 200 Hawkins Drive, Iowa City, IA, 52242, USA
| | - Nicholas H Fain
- Department of Radiology, University of Iowa Hospitals and Clinics, 200 Hawkins Drive, Iowa City, IA, 52242, USA
| | - Neetu Soni
- Department of Radiology, University of Iowa Hospitals and Clinics, 200 Hawkins Drive, Iowa City, IA, 52242, USA
| | - Caitlin Ward
- Department of Biostatistics, University of Iowa, Iowa City, IA, USA
| | - Colin P Derdeyn
- Department of Radiology, University of Iowa Hospitals and Clinics, 200 Hawkins Drive, Iowa City, IA, 52242, USA
| |
Collapse
|
9
|
Tang S, Zhang G, Chen Z, Liu X, Fan X, Liu D, He L. Application of multiple injections of contrast agent in head and neck CT arteriovenous angiography in children: Study protocol clinical trial (SPIRIT Compliant). Medicine (Baltimore) 2020; 99:e19773. [PMID: 32282739 PMCID: PMC7220194 DOI: 10.1097/md.0000000000019773] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/05/2023] Open
Abstract
OBJECTIVE To investigate the application value of multiple injections of contrast agent in head and neck CT arteriovenous angiography in children. METHODS A total of 100 children aged 6 to 7 years who needed head and neck CT arteriovenous angiography were prospectively selected. They were randomly divided into a control group and a research group, with 50 children in each group. The same scanning parameters and reconstruction methods were used. The right median cubital vein was injected intravenously with the contrast agent Omnipaque (350 mg I/ml). For children in the control group, a bolus of undiluted contrast agent (dose was 2 ml/kg, upper limit was 50 ml) was injected 1 time. The arterial phase and vein phase of the head and neck vessels were scanned. For children in the research group, a contrast agent bolus diluted with saline to a concentration of 20% was first injected (dose was 1 ml/kg, upper limit was 25 ml), and then an undiluted contrast agent bolus (dose was 1 ml/kg, upper limit was 25 ml) was injected. Thresholds were used to trigger the scanning of the head and neck arterial phases. The CT image quality of the head and neck arteries and veins, radiation dose and contrast agent dose were compared between the 2 groups. RESULTS Subjective evaluation of CT image quality of arteries: there were 47 cases of 4 points and 3 cases of 3 points in the control group and 34 cases of 4 points and 16 cases of 3 points in the research group. Subjective evaluation of CT image quality of veins: there were 47 cases of 4 points and 3 cases of 3 points in the control group and 5 cases of 4 points, 42 cases of 3 points and 3 cases of 2 points in the research group. The CT value of brain arterial vessel enhancement was higher in the control group than the research group, and the difference was statistically significant (P < .05). The CT value of vein enhancement was higher in the control group than the research group, and the difference was statistically significant (P < .05). The X-ray dose in the research group was 51% lower than that in the control group; the contrast agent dose in the research group was 44% lower than that in the control group. CONCLUSION For the head and neck enhanced CT examination of children, the method of first bolus injection of 20% diluted contrast agent and later bolus injection of undiluted contrast agent can clearly demonstrate the head and neck arteries and veins one time, reducing the X-ray dose and contrast agent dose, which has clinical practical value in the enhanced CT examination of children with head and neck disease.
Collapse
Affiliation(s)
| | - Guanping Zhang
- National Clinical Research Center for Child Health and Disorders
| | - Zhuo Chen
- Department of Radiology
- Chongqing Key Laboratory of Pediatrics, Children's Hospital of Chongqing Medical University, Chongqing, China
| | - Xianfan Liu
- Ministry of Education Key Laboratory of Child Development and Disorders
| | - Xiao Fan
- China International Science and Technology Cooperation base of Child development and Critical Disorders
| | | | | |
Collapse
|
10
|
Tube Current Reduction in CT Angiography: How Low Can We Go in Imaging of Patients With Suspected Acute Stroke? AJR Am J Roentgenol 2019; 213:410-416. [DOI: 10.2214/ajr.18.20954] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
11
|
Chen CW, Chen PA, Chou CC, Fu JH, Wang PC, Hsu SH, Lai PH. Combination of Adaptive Statistical Iterative Reconstruction-V and Lower Tube Voltage During Craniocervical Computed Tomographic Angiography Yields Better Image Quality with a Reduced Radiation Dose. Acad Radiol 2019; 26:e233-e240. [PMID: 30195416 DOI: 10.1016/j.acra.2018.07.019] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2018] [Revised: 07/24/2018] [Accepted: 07/27/2018] [Indexed: 02/06/2023]
Abstract
RATIONALE AND OBJECTIVES To evaluate image quality and radiation exposure when using the adaptive statistical iterative reconstruction-V (ASIR-V) algorithm for reconstructing craniocervical computed tomographic angiography images acquired at 100 kVp. MATERIALS AND METHODS We randomly divided 121 patients into three groups: group A (conventional protocol), 120 kVp with filtered back projection; group B, 120 kVp with 50% ASIR-V; and group C, 100 kVp with 50% ASIR-V. All patients underwent scans in a 256-slice computed tomography (CT) scanner. Radiation dose (volume CT dose index), dose-length product, and effective dose, objective parameters such as arterial attenuation value, signal-to-noise ratio, contrast-to-noise ratio, and noise obtained at head, neck, and shoulder levels were compared among the groups. Subjective image quality was independently assessed by two radiologists, and interobserver reliability was assessed using kappa analysis. RESULTS The radiation dose in group C was the lowest (p < 0.01) with a 40% reduction in volume CT dose index, dose-length product, and effective dose values compared to group A, and group C showed higher arterial attenuation than either group A or B (p < 0.01). Additionally, signal-to-noise ratio and contrast-to-noise ratio were higher and noise was lower in groups B and C than group A. Group C had better subjective image quality than groups A and B (p < 0.05), and the interobserver reliability between the two radiologists was high (k = 0.783). CONCLUSION Compared to the conventional protocol, using 50% ASIR-V and the 100 kVp protocol during craniocervical computed tomographic angiography yields better objective and subjective image quality at lower radiation doses.
Collapse
|
12
|
Forbrig R, Geyer LL, Stahl R, Thorsteinsdottir J, Schichor C, Kreth FW, Patzig M, Herzberg M, Liebig T, Dorn F, Trumm CG. Radiation dose and image quality in intraoperative CT (iCT) angiography of the brain with stereotactic head frames. Eur Radiol 2019; 29:2859-2867. [PMID: 30635759 DOI: 10.1007/s00330-018-5930-0] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2018] [Revised: 11/06/2018] [Accepted: 11/28/2018] [Indexed: 01/04/2023]
Abstract
OBJECTIVES Intraoperative CT (iCT) angiography of the brain with stereotactic frames is an integral part of navigated neurosurgery. Validated data regarding radiation dose and image quality in these special examinations are not available. We therefore investigated two iCT protocols in this IRB-approved study. METHODS Retrospective analysis of patients, who received a cerebral stereotactic iCT angiography on a 128 slice CT scanner between February 2016 and December 2017. In group A, automated tube current modulation (ATCM; reference value 410 mAs) and automated tube voltage selection (reference value 120 kV) were enabled, and only examinations with a selected voltage of 120 kV were included. In group B, fixed parameters were applied (300 mAs, 120 kV). Radiation dose was measured by assessing the volumetric CT dose index (CTDIvol), dose length product (DLP) and effective dose (ED). Signal-to-noise ratio (SNR) and image noise were assessed for objective image quality, visibility of arteries and grey-white differentiation for subjective image quality. RESULTS Two hundred patients (n = 100 in each group) were included. In group A, median selected tube current was 643 mAs (group B, 300 mAs; p < 0.001). Median values of CTDIvol, DLP and ED were 91.54 mGy, 1561 mGy cm and 2.97 mSv in group A, and 43.15 mGy, 769 mGy cm and 1.46 mSv in group B (p < 0.001). Image quality did not significantly differ between groups (p > 0.05). CONCLUSIONS ATCM yielded disproportionally high radiation dose due to substantial tube current increase at the frame level, while image quality did not improve. Thus, ATCM should preferentially be disabled. KEY POINTS • Automated tube current modulation (ATCM) yields disproportionally high radiation dose in intraoperative CT angiography of the brain with stereotactic head frames. • ATCM does not improve overall image quality in these special examinations. • ATCM is not yet optimised for CT angiography of the brain with major extracorporeal foreign materials within the scan range.
Collapse
Affiliation(s)
- Robert Forbrig
- Institute of Neuroradiology, University Hospital, LMU Munich, Marchioninistrasse 15, 81377, Munich, Germany.
| | - Lucas L Geyer
- Center of Radiology and Neuroradiology, Klinikum Ingolstadt, Ingolstadt, Germany
| | - Robert Stahl
- Department of Radiology, University Hospital, LMU Munich, Munich, Germany
| | | | - Christian Schichor
- Department of Neurosurgery, University Hospital, LMU Munich, Munich, Germany
| | | | - Maximilian Patzig
- Institute of Neuroradiology, University Hospital, LMU Munich, Marchioninistrasse 15, 81377, Munich, Germany
| | - Moriz Herzberg
- Institute of Neuroradiology, University Hospital, LMU Munich, Marchioninistrasse 15, 81377, Munich, Germany
| | - Thomas Liebig
- Institute of Neuroradiology, University Hospital, LMU Munich, Marchioninistrasse 15, 81377, Munich, Germany
| | - Franziska Dorn
- Institute of Neuroradiology, University Hospital, LMU Munich, Marchioninistrasse 15, 81377, Munich, Germany
| | - Christoph G Trumm
- Institute for Diagnostic and Interventional Radiology, Neuroradiology and Nuclear Medicine, Städtisches Klinikum München Harlaching, Munich, Germany
| |
Collapse
|
13
|
Cheng B, Xing H, Lei D, Guo Y, Ning G, Gong Q, Cai W. Impact of iterative model reconstruction combined with dose reduction on the image quality of head and neck CTA in children. Sci Rep 2018; 8:12613. [PMID: 30135541 PMCID: PMC6105670 DOI: 10.1038/s41598-018-30300-4] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2018] [Accepted: 07/26/2018] [Indexed: 02/05/2023] Open
Abstract
This study aimed to evaluate the imaging quality of head and neck computed tomographic angiography (CTA) in pediatric patients at a lowered radiation dose by combining an iterative model reconstruction (IMR) with low voltage scanning. Eighty-three pediatric patients were randomized into two groups as follows: Group A (n = 42), 100 kV/50 ml contrast media (CM), using filtered back projection (FBP); and Group B (n = 41), 80 kV/30 ml CM, using IMR. The enhanced CT value of the arteries, the image noise, the signal-to-noise ratio (SNR)/contrast-to-noise ratio (CNR), the image quality, the effective radiation dose (ED) and the iodine intake were compared between the two groups. The mean ED and iodine intake of group B were reduced by 69.8% and 40.0%, respectively, compared to those of group A. The mean CT values of the arteries in group B were higher than those in group A (p < 0.01), whereas the image noise of group B was lower than that of group A (p < 0.01). Group B exhibited a better image quality and a higher mean CNR/SNR than that of group A (p < 0.01). Compared to FBP, IMR in head and neck CTA enables a significant reduction in the radiation dose while preserving the diagnostic image quality. Thus, IMR, combined with low tube voltage scanning, provided an excellent solution for improving the image quality of craniocervical vessels in children.
Collapse
Affiliation(s)
- Bochao Cheng
- Department of Radiology, West China Second University Hospital, Sichuan University, Chengdu, China
- Huaxi MR Research Center, Department of Radiology, West China Hospital of Sichuan University, Chengdu, China
| | - Haoyang Xing
- Huaxi MR Research Center, Department of Radiology, West China Hospital of Sichuan University, Chengdu, China
- College of Physical Science and Technology, Sichuan University, Chengdu, China
| | - Du Lei
- Department of Psychosis Studies, Institute of Psychiatry, Psychology & Neuroscience, King's College London, London, UK
| | - Yingkun Guo
- Department of Radiology, West China Second University Hospital, Sichuan University, Chengdu, China
- Key Laboratory of Birth Defects and Related Diseases of Women and Children (Sichuan University), Ministry of Education, Chengdu, China
| | - Gang Ning
- Department of Radiology, West China Second University Hospital, Sichuan University, Chengdu, China
| | - Qiyong Gong
- Huaxi MR Research Center, Department of Radiology, West China Hospital of Sichuan University, Chengdu, China
| | - Wu Cai
- Department of Radiology, Second Affiliated Hospital of Soochow University, Suzhou, China.
| |
Collapse
|
14
|
Improved display of cervical intervertebral discs on water (iodine) images: incidental findings from single-source dual-energy CT angiography of head and neck arteries. Eur Radiol 2018; 29:153-160. [DOI: 10.1007/s00330-018-5603-z] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2018] [Revised: 05/28/2018] [Accepted: 06/07/2018] [Indexed: 12/16/2022]
|