1
|
Austin K, Torres JA, Waters JDV, Balog ERM, Halpern JM, Pantazes RJ. An Orthogonal Workflow of Electrochemical, Computational, and Thermodynamic Methods Reveals Limitations of Using a Literature-Reported Insulin Binding Peptide in Biosensors. ACS OMEGA 2024; 9:39219-39231. [PMID: 39310205 PMCID: PMC11411520 DOI: 10.1021/acsomega.4c06481] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/13/2024] [Revised: 08/23/2024] [Accepted: 08/29/2024] [Indexed: 09/25/2024]
Abstract
Developing a continuous insulin-monitoring biosensor is of great importance for both the cellular biomanufacturing industry and for treating diabetes mellitus. Such a sensor needs to be able to effectively monitor insulin across a range of temperatures and pHs and with varying concentrations of competing analytes. One of the two main components of any biosensor is the recognition element, which is responsible for interacting with the molecule of interest. Prior literature describes an insulin-binding peptide (IBP) that was reported to bind to insulin with a 3 nM affinity. Here, we used orthogonal and complementary electrochemical, computational, and thermodynamic characterization methods to evaluate IBP's appropriateness for use in a biosensor. Unfortunately, all three methods failed to produce evidence of IBP-insulin binding either on surfaces or in solution. This indicates that the binding exhibited in previous reports is likely restricted to a limited set of conditions and that IBP is not a suitable recognition element for a continuous insulin biosensor.
Collapse
Affiliation(s)
- Katherine Austin
- Department
of Chemical Engineering and Bioengineering, University of New Hampshire, Durham, New Hampshire 03824, United States
| | - Jazmine A. Torres
- Department
of Chemical Engineering, Auburn University, Auburn, Alabama 36849, United States
| | - Jeffery D. V. Waters
- School
of Molecular and Physical Sciences, University
of New England, Biddeford, Maine 04005, United States
| | - Eva Rose M. Balog
- School
of Molecular and Physical Sciences, University
of New England, Biddeford, Maine 04005, United States
| | - Jeffrey M. Halpern
- Department
of Chemical Engineering and Bioengineering, University of New Hampshire, Durham, New Hampshire 03824, United States
| | - Robert J. Pantazes
- Department
of Chemical Engineering, Auburn University, Auburn, Alabama 36849, United States
| |
Collapse
|
2
|
Kamalasekaran K, Sundramoorthy AK. Applications of chemically modified screen-printed electrodes in food analysis and quality monitoring: a review. RSC Adv 2024; 14:27957-27971. [PMID: 39224631 PMCID: PMC11367709 DOI: 10.1039/d4ra02470b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2024] [Accepted: 08/23/2024] [Indexed: 09/04/2024] Open
Abstract
Food analysis and food quality monitoring are vital aspects of the food industry, ensuring the safety and authenticity of various food products, from packaged goods to fast food. In this comprehensive review, we explore the applications of chemically modified Screen-Printed Electrodes (SPEs) in these critical domains. SPEs have become extremely useful devices for ensuring food safety and quality assessment because of their adaptability, affordability, and convenience of use. The Introduction opens the evaluation, that covers a wide spectrum of foods, encompassing packaged, junk food, and food quality concerns. This sets the stage for a detailed exploration of chemically modified SPEs, including their nature, types, utilization, and the advantages they offer in the context of food analysis. Subsequently, the review delves into the multitude applications of SPEs in food analysis, ranging from the detection of microorganisms such as bacteria and fungi, which are significant indicators of food spoilage and safety, to the identification of pesticide residues, food colorants, chemicals, toxins, and antibiotics. Furthermore, chemically modified SPEs have proven to be invaluable in the quantification of metal ions and vitamins in various food matrices, shedding light on nutritional content and quality.
Collapse
Affiliation(s)
- Kavitha Kamalasekaran
- Department of Chemistry, Velammal Engineering College Chennai 600066 Tamil Nadu India
| | - Ashok K Sundramoorthy
- Centre for Nano-Biosensors, Department of Prosthodontics and Materials Science, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences Chennai 600077 Tamil Nadu India
| |
Collapse
|
3
|
Zhou L, Zhu R, Figueroa-Miranda G, Neis M, Offenhäusser A, Mayer D. Ratiometric electrochemical aptasensor with strand displacement for insulin detection in blood samples. Anal Chim Acta 2024; 1317:342823. [PMID: 39029996 DOI: 10.1016/j.aca.2024.342823] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2024] [Revised: 05/30/2024] [Accepted: 06/03/2024] [Indexed: 07/21/2024]
Abstract
BACKGROUND Diabetes patients suffer either from insulin deficiency or resistance with a high risk of severe long-term complications, thus the quantitative assessment of insulin level is highly desired for diabetes surveillance and management. Utilizing insulin-capturing aptamers may facilitate the development of affordable biosensors however, their rigid G-quadruplex structures impair conformational changes of the aptamers and diminish the sensor signals. RESULTS Here we report on a ratiometric, electrochemical insulin aptasensor which is achieved by hybridization of an insulin-capturing aptamer and a partially complementary ssDNA to break the rigid G-quadruplex structures. To improve the durability of the aptasensor, the capturing aptamer was immobilized on gold electrodes via two dithiol-phosphoramidite functional groups while methoxy-polyethylene glycol thiol was used as a blocking molecule. The exposure of the sensor to insulin-containing solutions induced the dissociation of the hybridized DNA accompanied by a conformational rearrangement of the capturing aptamer back into a G-quadruplex structure. The reliability of sensor readout was improved by the adoption of an AND logic gate utilizing anthraquinone and methylene blue redox probes associated to the aptamer and complementary strand, respectively. Our aptasensor possessed an improved detection limit of 0.15 nM in comparison to aptasensors without strand displacement. SIGNIFICANCE The sensor was adapted for detection in real blood and is ready for future PoC diagnostics. The capability of monitoring the insulin level in an affordably manner can improve the treatment for an increasing number of patients in developed and developing nations. The utilization of low-cost and versatile aptamer receptors together with the engineering of ratiometric electrochemical signal recording has the potential to considerably advance the current insulin detection technology toward multi-analyte diabetes sensors.
Collapse
Affiliation(s)
- Lei Zhou
- Institute of Biological Information Processing, Bioelectronics (IBI-3), Forschungszentrum Jülich GmbH, Jülich, Germany; Faculty I, RWTH Aachen University, Aachen, Germany
| | - Ruifeng Zhu
- Institute of Biological Information Processing, Bioelectronics (IBI-3), Forschungszentrum Jülich GmbH, Jülich, Germany
| | - Gabriela Figueroa-Miranda
- Institute of Biological Information Processing, Bioelectronics (IBI-3), Forschungszentrum Jülich GmbH, Jülich, Germany
| | - Marc Neis
- Institute of Biological Information Processing, Bioelectronics (IBI-3), Forschungszentrum Jülich GmbH, Jülich, Germany
| | - Andreas Offenhäusser
- Institute of Biological Information Processing, Bioelectronics (IBI-3), Forschungszentrum Jülich GmbH, Jülich, Germany
| | - Dirk Mayer
- Institute of Biological Information Processing, Bioelectronics (IBI-3), Forschungszentrum Jülich GmbH, Jülich, Germany.
| |
Collapse
|
4
|
Ibrahim N, Gan KB, Mohd Yusof NY, Goh CT, Krupa B N, Tan LL. Electrochemical genosensor based on RNA-responsive human telomeric G-quadruplex DNA: A proof-of-concept with SARS-CoV-2 RNA. Talanta 2024; 274:125916. [PMID: 38547835 DOI: 10.1016/j.talanta.2024.125916] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2023] [Revised: 01/07/2024] [Accepted: 03/11/2024] [Indexed: 05/04/2024]
Abstract
In this report, a facile and label-free electrochemical RNA biosensor is developed by exploiting methylene blue (MB) as an electroactive positive ligand of G-quadruplex. The electrochemical response mechanism of the nucleic acid assay was based on the change in differential pulse voltammetry (DPV) signal of adsorbed MB on the immobilized human telomeric G-quadruplex DNA with a loop that is complementary to the target RNA. Hybridization between synthetic positive control RNA and G-quadruplex DNA probe on the transducer platform rendered a conformational change of G-quadruplex to double-stranded DNA (dsDNA), and increased the redox current of cationic MB π planar ligand at the sensing interface, thereby the electrochemical signal of the MB-adsorbed duplex is proportional to the concentration of target RNA, with SARS-CoV-2 (COVID-19) RNA as the model. Under optimal conditions, the target RNA can be detected in a linear range from 1 zM to 1 μM with a limit of detection (LOD) obtained at 0.59 zM for synthetic target RNA and as low as 1.4 copy number for positive control plasmid. This genosensor exhibited high selectivity towards SARS-CoV-2 RNA over other RNA nucleotides, such as SARS-CoV and MERS-CoV. The electrochemical RNA biosensor showed DPV signal, which was proportional to the 2019-nCoV_N_positive control plasmid from 2 to 200000 copies (R2 = 0.978). A good correlation between the genosensor and qRT-PCR gold standard was attained for the detection of SARS-CoV-2 RNA in terms of viral copy number in clinical samples from upper respiratory specimens.
Collapse
Affiliation(s)
- Nadiah Ibrahim
- Southeast Asia Disaster Prevention Research Initiative (SEADPRI), Institute for Environment and Development (LESTARI), Universiti Kebangsaan Malaysia, 43600, UKM Bangi, Selangor Darul Ehsan, Malaysia.
| | - Kok Beng Gan
- Faculty of Engineering and Built Environment, Universiti Kebangsaan Malaysia, 43600, UKM Bangi, Selangor Darul Ehsan, Malaysia.
| | - Nurul Yuziana Mohd Yusof
- Department of Earth Sciences and Environment, Faculty of Science and Technology, Universiti Kebangsaan Malaysia, 43600, UKM Bangi, Selangor Darul Ehsan, Malaysia.
| | - Choo Ta Goh
- Southeast Asia Disaster Prevention Research Initiative (SEADPRI), Institute for Environment and Development (LESTARI), Universiti Kebangsaan Malaysia, 43600, UKM Bangi, Selangor Darul Ehsan, Malaysia.
| | - Niranjana Krupa B
- Department of Electronics and Communication Engineering, PES University, Bengaluru-85, Karnataka, India.
| | - Ling Ling Tan
- Southeast Asia Disaster Prevention Research Initiative (SEADPRI), Institute for Environment and Development (LESTARI), Universiti Kebangsaan Malaysia, 43600, UKM Bangi, Selangor Darul Ehsan, Malaysia.
| |
Collapse
|
5
|
Mohammadinejad A, Heydari M, Kazemi Oskuee R, Rezayi M. A Critical Systematic Review of Developing Aptasensors for Diagnosis and Detection of Diabetes Biomarkers. Crit Rev Anal Chem 2022; 52:1795-1817. [DOI: 10.1080/10408347.2021.1919986] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Affiliation(s)
- Arash Mohammadinejad
- Targeted Drug Delivery Research Center, Mashhad University of Medical Sciences, Mashhad, Iran
- Department of Medical Biotechnology and Nanotechnology, School of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Maryam Heydari
- Medical Toxicology Research Center, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Reza Kazemi Oskuee
- Targeted Drug Delivery Research Center, Mashhad University of Medical Sciences, Mashhad, Iran
- Department of Medical Biotechnology and Nanotechnology, School of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Majid Rezayi
- Department of Medical Biotechnology and Nanotechnology, School of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran
- Medical Toxicology Research Center, Mashhad University of Medical Sciences, Mashhad, Iran
| |
Collapse
|
6
|
Trends in advanced materials for the fabrication of insulin electrochemical immunosensors. CHEMICAL PAPERS 2022. [DOI: 10.1007/s11696-022-02416-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
7
|
Sakthivel R, Lin LY, Duann YF, Chen HH, Su C, Liu X, He JH, Chung RJ. MOF-Derived Cu-BTC Nanowire-Embedded 2D Leaf-like Structured ZIF Composite-Based Aptamer Sensors for Real-Time In Vivo Insulin Monitoring. ACS APPLIED MATERIALS & INTERFACES 2022; 14:28639-28650. [PMID: 35709524 DOI: 10.1021/acsami.2c06785] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Insulin, which is a hormone produced by the β-cells of the pancreas, regulates the glucose levels in the blood and can transport glucose into cells to produce glycogen or triglycerides. Insulin deficiency can lead to hyperglycemia and diabetes. Therefore, insulin detection is critical in clinical diagnosis. In this study, disposable Au electrodes were modified with copper(II) benzene-1,3,5-tricarboxylate (Cu-BTC)/leaf-like zeolitic imidazolate framework (ZIF-L) for insulin detection. The aptamers are easily immobilized on the Cu-BTC/ZIF-L composite by physical adsorption and facilitated the specific interaction between aptamers and insulin. The Cu-BTC/ZIF-L composite-based aptasensor presented a wide linear insulin detection range (0.1 pM to 5 μM) and a low limit of detection of 0.027 pM. In addition, the aptasensor displayed high specificity, good reproducibility and stability, and favorable practicability in human serum samples. For the in vivo tests, Cu-BTC/ZIF-L composite-modified electrodes were implanted in non-diabetic and diabetic mice, and insulin was quantified using electrochemical and enzyme-linked immunosorbent assay methods.
Collapse
Affiliation(s)
- Rajalakshmi Sakthivel
- Department of Chemical Engineering and Biotechnology, National Taipei University of Technology (Taipei Tech), Taipei 10608, Taiwan
| | - Lu-Yin Lin
- Department of Chemical Engineering and Biotechnology, National Taipei University of Technology (Taipei Tech), Taipei 10608, Taiwan
| | - Yeh-Fang Duann
- Department of Chemical Engineering and Biotechnology, National Taipei University of Technology (Taipei Tech), Taipei 10608, Taiwan
| | - Hsiao-Hsuan Chen
- Department of Chemical Engineering and Biotechnology, National Taipei University of Technology (Taipei Tech), Taipei 10608, Taiwan
| | - Chaochin Su
- Institute of Organic and Polymeric Materials, Research and Development Center for Smart Textile Technology,National Taipei University of Technology (Taipei Tech), Taipei 10608, Taiwan
| | - Xinke Liu
- College of Materials Science and Engineering, Shenzhen University, Shenzhen 518060, China
| | - Jr-Hau He
- Department of Materials Science and Engineering, City University of Hong Kong, 26 Kowloon, Kowloon 999077, Hong Kong
| | - Ren-Jei Chung
- Department of Chemical Engineering and Biotechnology, National Taipei University of Technology (Taipei Tech), Taipei 10608, Taiwan
| |
Collapse
|
8
|
An electrochemical signal switch–based (on–off) aptasensor for sensitive detection of insulin on gold-deposited screen-printed electrodes. J Solid State Electrochem 2022. [DOI: 10.1007/s10008-022-05133-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
9
|
Liu J, Zhu B, Dong H, Zhang Y, Xu M, Travas-Sejdic J, Chang Z. A novel electrochemical insulin aptasensor: From glassy carbon electrodes to disposable, single-use laser-scribed graphene electrodes. Bioelectrochemistry 2022; 143:107995. [PMID: 34794112 DOI: 10.1016/j.bioelechem.2021.107995] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2021] [Revised: 10/25/2021] [Accepted: 11/04/2021] [Indexed: 12/19/2022]
Abstract
Insulin, a peptide hormone secreted by pancreatic β cells, affects the development of diabetes and associated complications. Herein, we propose an electrochemical aptasensor for sensitive and selective detection of insulin using laser-scribed graphene electrodes (LSGEs). Before using disposable LSGEs, the development and proof-of-concept sensing experiments were firstly carried out on research-grade glassy carbon electrode (GCE). The aptasensor is based on using Exonuclease I (Exo I) that catalyses the hydrolysis of single-stranded aptamers attached to the electrode surface; however, the hydrolysis does not occur if the insulin is bound to the aptamer. Therefore, the unbound aptamers are cleaved by Exo I while insulin-bound aptamers remain on the electrode surface. In the next step, the gold nanoparticle - aptamer (AuNPs-Apt) probes are introduced to the electrode surface to form a 'sandwich' structure with the insulin on the surface-attached aptamer. The redox probe, methylene blue (MB), intercalates into the aptamers' guanine bases and the sandwich structure of AuNPs-Apt/insulin/surface-bound aptamer amplifies electrochemical signal from MBs. The signal can be well-correlated to the concentrations of insulin. A limit of detection of 22.7 fM was found for the LSGE-based sensors and 9.8 fM for GCE-based sensors used for comparison and initial sensor development. The results demonstrate successful fabrication of the single-use and sensitive LSGEs-based sensors for insulin detection.
Collapse
Affiliation(s)
- Jinjin Liu
- College of Chemistry, Zhengzhou University, Zhengzhou 450001, China
| | - Bicheng Zhu
- Polymer Biointerface Centre, School of Chemical Sciences, The University of Auckland, Private Bag, 92019 Auckland, New Zealand; MacDiarmid Institute for Advanced Materials and Nanotechnology, Victoria University of Wellington, PO Box 600, Wellington, New Zealand
| | - Hui Dong
- Henan Key Laboratory of Biomolecular Recognition and Sensing, College of Chemistry and Chemical Engineering, Henan Joint International Research Laboratory of Chemo/Biosensing and Early Diagnosis of Major Diseases, Shangqiu Normal University, Shangqiu 476000, Henan Province, PR China
| | - Yintang Zhang
- Henan Key Laboratory of Biomolecular Recognition and Sensing, College of Chemistry and Chemical Engineering, Henan Joint International Research Laboratory of Chemo/Biosensing and Early Diagnosis of Major Diseases, Shangqiu Normal University, Shangqiu 476000, Henan Province, PR China
| | - Maotian Xu
- Henan Key Laboratory of Biomolecular Recognition and Sensing, College of Chemistry and Chemical Engineering, Henan Joint International Research Laboratory of Chemo/Biosensing and Early Diagnosis of Major Diseases, Shangqiu Normal University, Shangqiu 476000, Henan Province, PR China
| | - Jadranka Travas-Sejdic
- Polymer Biointerface Centre, School of Chemical Sciences, The University of Auckland, Private Bag, 92019 Auckland, New Zealand; MacDiarmid Institute for Advanced Materials and Nanotechnology, Victoria University of Wellington, PO Box 600, Wellington, New Zealand.
| | - Zhu Chang
- Henan Key Laboratory of Biomolecular Recognition and Sensing, College of Chemistry and Chemical Engineering, Henan Joint International Research Laboratory of Chemo/Biosensing and Early Diagnosis of Major Diseases, Shangqiu Normal University, Shangqiu 476000, Henan Province, PR China.
| |
Collapse
|
10
|
An ultrasensitive electrochemical aptasensor based on a single-stranded aptamer-Au@Fe-MIL-88 complex using methylene blue as an electrochemical probe for insulin detection. Anal Bioanal Chem 2021; 413:7451-7462. [PMID: 34668997 DOI: 10.1007/s00216-021-03703-y] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2021] [Revised: 09/18/2021] [Accepted: 09/27/2021] [Indexed: 10/20/2022]
Abstract
This work introduces an electrochemical aptasensor based on a single-stranded aptamer-Au@Fe-MIL-88 complex for sensitive and selective determination of insulin using differential pulls voltammetry. Au@Fe-MIL-88 with a large surface area was synthesized and employed as a suitable substrate for immobilization of the aptamer (APT-Au@Fe-MIL-88). Methylene blue (MB), as an electrochemical probe, was intercalated into the aptamer. Graphene oxide (GO) and zinc sulfide (ZnS) were placed on the Au electrode to amplify the MB current. Also, ZnS improves the immobilization of APT-Au@Fe-MIL-88 into the aptasensor through the strong interaction of Au-S. In the presence of the insulin, MB is released from the aptamer due to DNA conformational change, and as a result, the peak intensity of the intercalated MB was decreased. Under optimal conditions, the change in the current of MB was proportional to the insulin concentration in the range of 5.0 × 10-16-5.0 × 10-11 mol L-1, with a superior ultra-low detection limit of 1.3 × 10-16 mol L-1. It was observed that the aptasensor is suitable for determining insulin in serum samples with good sensitivity and reproducibility and with recoveries ranging from 96.4 to 102.0%. The relative standard deviations (RSD) were lower than 3.8% (n = 3).
Collapse
|
11
|
Nur Topkaya S, Cetin AE. Electrochemical Aptasensors for Biological and Chemical Analyte Detection. ELECTROANAL 2020. [DOI: 10.1002/elan.202060388] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Affiliation(s)
- Seda Nur Topkaya
- Izmir Katip Celebi University Faculty of Pharmacy, Department of Analytical Chemistry 35620, Cigli Izmir TURKEY
| | - Arif E. Cetin
- Izmir Biomedicine and Genome Center 35330, Balcova Izmir TURKEY
| |
Collapse
|
12
|
A target-induced amperometic aptasensor for sensitive zearalenone detection by CS@AB-MWCNTs nanocomposite as enhancers. Food Chem 2020; 340:128128. [PMID: 33010646 DOI: 10.1016/j.foodchem.2020.128128] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2020] [Revised: 09/10/2020] [Accepted: 09/15/2020] [Indexed: 01/20/2023]
Abstract
In this research, a novel signal-on aptasensor for highly sensitive detection of zearalenone (ZEN) was reported based on target-induced amplification strategy. Specifically, chitosan functionalized acetylene black and multi-walled carbon nanotubes (CS@AB-MWCNTs) nanocomposite with large specific surface area and excellent conductivity was synthesized and served as the sensing platform. In addition, carboxylated graphene oxide-labeled ZEN binding aptamer (CGO-ZBA) would specifically recognized with ZEN to detach from the electrode, allowing the electrochemical signal of [Fe(CN)6]3-/4- increased more obviously. Under the optimal conditions, the proposed aptasensor exhibited exceptional detection performances for ZEN with a linear range from 10 fg mL-1 to 1 ng mL-1 and a low limit of detection of 3.64 fg mL-1. Given its great sensitivity, excellent selectivity, satisfactory stability and reproducibility, this method would provide a promising application for ZEN and other biomolecules by replacing the corresponding nucleicacidsequences.
Collapse
|
13
|
Nantaphol S, Moonla C, Promvichai S, Tangkuaram T, Chailapakul O, Siangproh W. A new alternative assay for sensitive analysis of ethylenethiourea and propylenethiourea in fruit samples after their separation. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2020; 12:3705-3712. [PMID: 32729855 DOI: 10.1039/d0ay01001d] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Ultra-high-performance liquid chromatography (UHPLC) coupled with a cobalt phthalocyanine screen-printed carbon electrode (CoPc-SPCE) was developed and validated for quantitative analysis of ethylenethiourea (ETU) and propylenethiourea (PTU). CoPC-SPCE provided high catalytic properties for ETU and PTU oxidation. This fabricated electrode is inexpensive, disposable, and easy to prepare by an in-house screen-printing technique. The chromatographic separation was performed in isocratic mode on a reversed phase C18 (100 mm × 4.6 mm, 3 μm) column, using a 90 : 10 (v/v) ratio of 0.05 M phosphate buffer solution (pH 4) and methanol as the mobile phase with a flow rate of 1.0 mL min-1 at an oxidation potential of +0.7 V vs. Ag/AgCl. The separation could be achieved within 3 min, and a wide linear range of 0.01-100 μg mL-1 (r2 > 0.99) was obtained for both analytes. The limits of detection (3 S/N) were found to be 0.006 and 0.009 μg mL-1 for ETU and PTU, respectively. Furthermore, this proposed method was utilized to determine ETU and PTU in fruit samples with satisfactory results, yielding excellent intra-day and inter-day relative standard deviations and recoveries. These results demonstrated that the proposed assay can be used as a new alternative way for inexpensive, rapid, selective and sensitive determination of ETU and PTU in fruit samples.
Collapse
Affiliation(s)
- Siriwan Nantaphol
- Electrochemical and Optical Spectroscopy Center of Excellence (EOSCE), Department of Chemistry, Faculty of Science, Chulalongkorn University, 254 Phayathai Road, Pathumwan, Bangkok, 10330, Thailand
| | | | | | | | | | | |
Collapse
|
14
|
Siller IG, Preuss JA, Urmann K, Hoffmann MR, Scheper T, Bahnemann J. 3D-Printed Flow Cells for Aptamer-Based Impedimetric Detection of E. coli Crooks Strain. SENSORS 2020; 20:s20164421. [PMID: 32784793 PMCID: PMC7472219 DOI: 10.3390/s20164421] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/29/2020] [Revised: 08/03/2020] [Accepted: 08/05/2020] [Indexed: 01/16/2023]
Abstract
Electrochemical spectroscopy enables rapid, sensitive, and label-free analyte detection without the need of extensive and laborious labeling procedures and sample preparation. In addition, with the emergence of commercially available screen-printed electrodes (SPEs), a valuable, disposable alternative to costly bulk electrodes for electrochemical (bio-)sensor applications was established in recent years. However, applications with bare SPEs are limited and many applications demand additional/supporting structures or flow cells. Here, high-resolution 3D printing technology presents an ideal tool for the rapid and flexible fabrication of tailor-made, experiment-specific systems. In this work, flow cells for SPE-based electrochemical (bio-)sensor applications were designed and 3D printed. The successful implementation was demonstrated in an aptamer-based impedimetric biosensor approach for the detection of Escherichia coli (E. coli) Crooks strain as a proof of concept. Moreover, further developments towards a 3D-printed microfluidic flow cell with an integrated micromixer also illustrate the great potential of high-resolution 3D printing technology to enable homogeneous mixing of reagents or sample solutions in (bio-)sensor applications.
Collapse
Affiliation(s)
- Ina G. Siller
- Institute of Technical Chemistry, Leibniz University Hannover, Callinstraße 5, 30167 Hannover, Germany; (I.G.S.); (J.-A.P.); (T.S)
| | - John-Alexander Preuss
- Institute of Technical Chemistry, Leibniz University Hannover, Callinstraße 5, 30167 Hannover, Germany; (I.G.S.); (J.-A.P.); (T.S)
| | - Katharina Urmann
- Department of Environmental Science and Engineering, California Institute of Technology, 1200 E. California Blvd., Pasadena, CA 91125, USA; (K.U.); (M.R.H.)
| | - Michael R. Hoffmann
- Department of Environmental Science and Engineering, California Institute of Technology, 1200 E. California Blvd., Pasadena, CA 91125, USA; (K.U.); (M.R.H.)
| | - Thomas Scheper
- Institute of Technical Chemistry, Leibniz University Hannover, Callinstraße 5, 30167 Hannover, Germany; (I.G.S.); (J.-A.P.); (T.S)
| | - Janina Bahnemann
- Institute of Technical Chemistry, Leibniz University Hannover, Callinstraße 5, 30167 Hannover, Germany; (I.G.S.); (J.-A.P.); (T.S)
- Correspondence: ; Tel.: +49-511-762-2568
| |
Collapse
|
15
|
Colorimetric and electrochemical sensing of As(III) using calix[4]pyrrole capped gold nanoparticles and evaluation of its cytotoxic activity. J INCL PHENOM MACRO 2020. [DOI: 10.1007/s10847-020-01005-x] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
|
16
|
Multicomponent nanohybrids of nickel/ferric oxides and nickel cobaltate spinel derived from the MOF-on-MOF nanostructure as efficient scaffolds for sensitively determining insulin. Anal Chim Acta 2020; 1110:44-55. [DOI: 10.1016/j.aca.2020.03.019] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/25/2019] [Revised: 03/08/2020] [Accepted: 03/09/2020] [Indexed: 12/29/2022]
|
17
|
Electrochemical biosensors based on nucleic acid aptamers. Anal Bioanal Chem 2020; 412:55-72. [PMID: 31912182 DOI: 10.1007/s00216-019-02226-x] [Citation(s) in RCA: 90] [Impact Index Per Article: 22.5] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2019] [Revised: 10/12/2019] [Accepted: 10/18/2019] [Indexed: 02/07/2023]
Abstract
During recent decades, nucleic acid aptamers have emerged as powerful biological recognition elements for electrochemical affinity biosensors. These bioreceptors emulate or improve on antibody-based biosensors because of their excellent characteristics as bioreceptors, including limitless selection capacity for a large variety of analytes, easy and cost-effective production, high stability and reproducibility, simple chemical modification, stable and oriented immobilization on electrode surfaces, enhanced target affinity and selectivity, and possibility to design them in target-sensitive 3D folded structures. This review provides an overview of the state of the art of electrochemical aptasensor technology, focusing on novel aptamer-based electroanalytical assay configurations and providing examples to illustrate the different possibilities. Future prospects for this technology are also discussed. Graphical abstract.
Collapse
|
18
|
Highly sensitive IRS based biosensor for the determination of cytochrome c as a cancer marker by using nanoporous anodic alumina modified with trypsin. Biosens Bioelectron 2019; 149:111828. [PMID: 31726275 DOI: 10.1016/j.bios.2019.111828] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2019] [Revised: 09/10/2019] [Accepted: 10/28/2019] [Indexed: 11/21/2022]
Abstract
The determination of cytochrome c in the human serum sample is a regular medical investigation performed to assess cancer diseases. Herein, we used interferometric reflectance spectroscopy (IRS) based biosensor for the determination of cytochrome c. For this purpose first, the nanoporous anodic alumina (NAA) was fabricated. Then, the NAA pore walls were functionalized with 3-aminopropyl trimethoxy silane (NAA-NH2). Subsequently, the trypsin enzyme was immobilized on the NAA pore walls. The sensing principle of proposed IRS sensor to cytochrome c is based on a change in the intensity of the reflected light to a charge-coupled device (CCD) detector after digesting of cytochrome c by immobilized trypsin enzymes on NAA-NH2 into the heme-peptide fragment. The heme-peptide fragment then oxidized 2,2'-azino-bis(3-ethylbenzothiazoline-6-sulphonic acid) (ABTS) to green color ABTS·- anion radical in the presence of hydrogen peroxide. The generated green color ABTS·- anion radical solution adsorbed the white light and therefore the intensity of the reflected light from NAA to the CCD decreased. The decrease in the intensity of the white light had a logarithmic relationship with the concentration of the cytochrome c in the range of 1-100 nM. The limit of detections (LOD) for cytochrome c was 0.5 nM. The proposed biosensor exhibited high selectivity, sensitivity, and good stability.
Collapse
|
19
|
Wang Z, Hu X, Sun N, Deng C. Aptamer-functionalized magnetic metal organic framework as nanoprobe for biomarkers in human serum. Anal Chim Acta 2019; 1087:69-75. [PMID: 31585568 DOI: 10.1016/j.aca.2019.08.038] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2019] [Revised: 08/13/2019] [Accepted: 08/19/2019] [Indexed: 12/20/2022]
Abstract
Human serum is a huge bioinformatics database of human physiological and pathological state, many proteins/peptides among which can serve as biomarkers for monitoring human's health condition, thereby being worth exploring. The simple and fast capture of biomarkers from human serum is the first key step to realize their accurate detection. In this work, we developed the aptamer functionalized magnetic metal organic framework nanoprobe, and furtherly combined with mass spectrometry technology to establish an efficient method of identifying biomarkers. Taking insulin as example of biomarker in human serum, we developed sulfhydryl human insulin aptamer functionalized magnetic metal organic framework (denoted as Mag MOF@Au@HIA) through the post-synthetic modification of MIL-101(Cr)-NH2 for testing the applicability of the established method. Depending on the strong magnetic responsiveness and high specific area as well as high-loaded human insulin aptamers, the limit of detection of insulin was down to 1 ng/mL and 2 ng/mL in the standard insulin solution and human serum, respectively. Moreover, a good linear relationship (R2 = 0.998) was obtained by using standard insulin solution with concentration range from 100 ng/mL to 5 ng/mL, based on which the capture recovery of insulin with Mag MOF@Au@HIA from human serum was demonstrated to be excellent. All of the results indicate that the aptamer-functionalized magnetic metal organic framework is a promising nanoprobe for biomarkers capture in human serum.
Collapse
Affiliation(s)
- Zidan Wang
- Department of Chemistry and the Fifth People's Hospital of Shanghai, Fudan University, Shanghai, 200433, China
| | - Xufang Hu
- Department of Chemistry and the Fifth People's Hospital of Shanghai, Fudan University, Shanghai, 200433, China
| | - Nianrong Sun
- Department of Gastroenterology and Hepatology, Zhongshan Hospital, Fudan University, Shanghai, 200433, China.
| | - Chunhui Deng
- Department of Chemistry and the Fifth People's Hospital of Shanghai, Fudan University, Shanghai, 200433, China; Institutes of Biomedical Sciences, Collaborative Innovation Center of Genetics and Development, Fudan University, Shanghai, 200433, China.
| |
Collapse
|
20
|
Optical, electrochemical and catalytic methods for in-vitro diagnosis using carbonaceous nanoparticles: a review. Mikrochim Acta 2019; 186:50. [DOI: 10.1007/s00604-018-3110-1] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2018] [Accepted: 11/25/2018] [Indexed: 12/16/2022]
|
21
|
Sun H, Wu S, Zhou X, Zhao M, Wu H, Luo R, Ding S. Electrochemical sandwich immunoassay for insulin detection based on the use of gold nanoparticle-modified MoS2 nanosheets and the hybridization chain reaction. Mikrochim Acta 2018; 186:6. [DOI: 10.1007/s00604-018-3124-8] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2018] [Accepted: 11/27/2018] [Indexed: 10/27/2022]
|
22
|
Farzin L, Shamsipur M, Samandari L, Sheibani S. Recent advances in designing nanomaterial based biointerfaces for electrochemical biosensing cardiovascular biomarkers. J Pharm Biomed Anal 2018; 161:344-376. [PMID: 30205301 DOI: 10.1016/j.jpba.2018.08.060] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2018] [Revised: 08/27/2018] [Accepted: 08/29/2018] [Indexed: 02/06/2023]
Abstract
Early diagnosis of cardiovascular disease (CVD) is critically important for successful treatment and recovery of patients. At present, detection of CVD at early stages of its progression becomes a major issue for world health. The nanoscale electrochemical biosensors exhibit diverse outstanding properties, rendering them extremely suitable for the determination of CVD biomarkers at very low concentrations in biological fluids. The unique advantages offered by electrochemical biosensors in terms of sensitivity and stability imparted by nanostructuring the electrode surface together with high affinity and selectivity of bioreceptors have led to the development of new electrochemical biosensing strategies that have introduced as interesting alternatives to conventional methodologies for clinical diagnostics of CVD. This review provides an updated overview of selected examples during the period 2005-2018 involving electrochemical biosensing approaches and signal amplification strategies based on nanomaterials, which have been applied for determination of CVD biomarkers. The studied CVD biomarkers include AXL receptor tyrosine kinase, apolipoproteins, cholesterol, C-reactive protein (CRP), D-dimer, fibrinogen (Fib), glucose, insulin, interleukins, lipoproteins, myoglobin, N-terminal pro-B-type natriuretic peptide (BNP), tumor necrosis factor alpha (TNF-α) and troponins (Tns) on electrochemical transduction format. Identification of new specific CVD biomarkers, multiplex bioassay for the simultaneous determination of biomarkers, emergence of microfluidic biosensors, real-time analysis of biomarkers and point of care validation with high sensitivity and selectivity are the major challenges for future research.
Collapse
Affiliation(s)
- Leila Farzin
- Radiation Application Research School, Nuclear Science and Technology Research Institute, 11365-3486, Tehran, Iran.
| | - Mojtaba Shamsipur
- Department of Chemistry, Razi University, 67149-67346, Kermanshah, Iran.
| | - Leila Samandari
- Department of Chemistry, Razi University, 67149-67346, Kermanshah, Iran
| | - Shahab Sheibani
- Radiation Application Research School, Nuclear Science and Technology Research Institute, 11365-3486, Tehran, Iran
| |
Collapse
|
23
|
Ultrasensitive immunoassay of insulin based on highly efficient electrochemiluminescence quenching of carboxyl-functionalized g-C3N4 through coreactant dual-consumption by NiPd-DNAzyme. J Electroanal Chem (Lausanne) 2018. [DOI: 10.1016/j.jelechem.2018.04.041] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
|