1
|
Spurzem GJ, Broderick RC, Li JZ, Sandler BJ, Horgan S, Jacobsen GR. Maximizing mesh mileage: evaluating the long-term performance of a novel hybrid mesh for ventral hernia repair. Hernia 2024; 28:1151-1159. [PMID: 38429399 DOI: 10.1007/s10029-024-02995-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2023] [Accepted: 02/18/2024] [Indexed: 03/03/2024]
Abstract
PURPOSE The objective of this study is to evaluate the safety and long-term outcomes of GORE Synecor™ in ventral hernia repair (VHR). METHODS This retrospective, single-center case review analyzed outcomes in patients who underwent VHR with Synecor from May 2016 to December 2022. Primary outcomes were hernia recurrence and mesh infection rates. Secondary outcomes were 30-day morbidity, 30-day mortality, 30-day readmission, re-operation, surgical-site infection (SSI) and occurrence (SSO) rates, and occurrences requiring intervention (SSOI). RESULTS 278 patients were identified. Mean follow-up was 24.1 (0.2-87.1) months. Mean hernia defect size was 63.4 (± 77.2) cm2. Overall hernia recurrence and mesh infection rates were 5.0% and 1.4% respectively. No mesh infections required full explantation. We report the following overall rates: 13.3% 30-day morbidity, 4.7% 30-day readmission, 2.9% re-operation, 7.2% SSI, 6.1% SSO, and 2.9% SSOI. 30-day morbidity was significantly higher in non-clean (42.1% vs 11.2%, p < 0.01), onlay (OL) mesh (37.0% vs preperitoneal (PP) 16.4%, p = 0.05 vs retrorectus (RR) 15.0%, p < 0.05 vs intraperitoneal (IP) 5.2%, p < 0.001), and open cases (23.5% vs 3.1% laparoscopic vs 4.4% robotic, p < 0.01). SSI rates were significantly higher in non-clean (31.6% vs 5.4%, p < 0.001), OL mesh (29.6% vs RR 11.3%, p < 0.05 vs PP 5.5%, p < 0.01 vs IP 0.0%, p < 0.001), and open cases (15.2% vs 0% laparoscopic vs 0% robotic, p < 0.05). CONCLUSION Long-term performance of a novel hybrid mesh in VHR demonstrates a low recurrence rate and favorable safety profile in various defect sizes and mesh placement locations.
Collapse
Affiliation(s)
- G J Spurzem
- Department of Surgery, Division of Minimally Invasive Surgery, University of California San Diego, 9300 Campus Point Dr, La Jolla, CA, 92037, USA.
| | - R C Broderick
- Department of Surgery, Division of Minimally Invasive Surgery, University of California San Diego, 9300 Campus Point Dr, La Jolla, CA, 92037, USA
| | - J Z Li
- Department of Surgery, Division of Minimally Invasive Surgery, University of California San Diego, 9300 Campus Point Dr, La Jolla, CA, 92037, USA
| | - B J Sandler
- Department of Surgery, Division of Minimally Invasive Surgery, University of California San Diego, 9300 Campus Point Dr, La Jolla, CA, 92037, USA
| | - S Horgan
- Department of Surgery, Division of Minimally Invasive Surgery, University of California San Diego, 9300 Campus Point Dr, La Jolla, CA, 92037, USA
| | - G R Jacobsen
- Department of Surgery, Division of Minimally Invasive Surgery, University of California San Diego, 9300 Campus Point Dr, La Jolla, CA, 92037, USA
| |
Collapse
|
2
|
Vestberg R, Lecuivre J, Radlovic A, Payet E, Bayon Y, Bouré L. A novel self-gripping long-term resorbable mesh providing temporary support for open primary ventral and incisional hernia. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 2023; 34:59. [PMID: 37943355 PMCID: PMC10635933 DOI: 10.1007/s10856-023-06762-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/26/2023] [Accepted: 10/23/2023] [Indexed: 11/10/2023]
Abstract
A novel synthetic fully long-term resorbable self-gripping mesh has been recently developed to reinforce soft tissue where weakness exists during ventral hernia repair open procedures. This resorbable mesh is a macroporous, knitted, poly-L-lactide, poly-trimethylene carbonate copolymer monofilament mesh with the ProGrip™ technology, providing grips on one side of the mesh. A new poly-L-lactide, poly-trimethylene copolymer was developed to provide the required features for mechanical support during at least 20 weeks covering the critical healing period, including resistance to fatigue under cyclic loading conditions, as it occurs in patients. The yarns and mesh initial physical and biomechanical properties were characterized. Then, the mesh mechanical strength was evaluated over time. The mechanical properties of the proposed mesh were found to be above the generally recognized threshold value to mechanically support the repair site of a hernia over a 20-week period during in-vitro cyclic loading test. The mesh performance was evaluated in vivo using a published preclinical porcine model of hernia repair at 4-, 12- and 20-weeks post implantation. The burst strength of the hernia repair sites reinforced with the new mesh were higher at 4 & 12 weeks and comparable at 20 weeks to the one of the native abdominal walls. At all time points, the mesh was well tolerated with moderate inflammation and was fast integrated in the abdominal wall at 4 weeks. Particularly, the grips were nicely engulfed in the newly formed connective tissue. They must facilitate the anchoring of the mesh by their extension from the mesh and their mushroom shape. The preclinical data of the self-gripping resorbable mesh suggests that it has all the favorable characteristics for future clinical use during ventral hernia repair open procedures.
Collapse
Affiliation(s)
| | | | | | - Emilie Payet
- Medtronic - Sofradim Production, Trévoux, F, France
| | - Yves Bayon
- Medtronic - Sofradim Production, Trévoux, F, France.
| | | |
Collapse
|
3
|
Perrone G, Giuffrida M, Bonati E, Petracca GL, Catena F. Biosynthetic meshes in contaminated fields: where are we now? A systematic review and meta-analysis in humans. Hernia 2023:10.1007/s10029-023-02763-6. [PMID: 36943520 DOI: 10.1007/s10029-023-02763-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2022] [Accepted: 03/09/2023] [Indexed: 03/23/2023]
Abstract
PURPOSE Selection of an appropriate mesh reinforcement for hernia repair in contaminated fields is a significant problem for surgeons. To date the proper mesh for contaminated fields has not been found. Biosynthetic meshes have emerged as new treatment option in contaminated fields. This study aims to evaluate the postoperative outcomes of biosynthetic meshes in contaminated fields. METHODS Systematic electronic search (PubMed, Medline, Embase, Scopus), according to PRISMA criteria, was performed. A literature search of scientific papers was performed by two reviewers until April 2021. Articles were chosen based on reference to biosynthetic meshes, their use in infected fields, and in human subjects. GRADE methodology and the modified Newcastle-Ottawa scale were used to assess the quality of studies. According to CDC-Centers for Disease Control classes patients were divided into two subgroups, group 1 (CDC class 2) and group 2 (CDC classes 3-4). RESULTS The research included 21 articles and 1619 patients were analyzed. Long-term follow-up showed a significant higher recurrence rate than short-term follow-up. P < 0.001. Meta-analysis of these studies showed that the SSI were significantly higher in CDC classes 3-4 than CDC class 2 (P < 0.01). No differences were found in SSO (P = 0.06) and recurrence (P = 0.37) rate among the two groups. Phasix™ was the most common mesh in 15 studies. The mean follow-up was 23.0 months. The surgical site infection (SSI) rate was 17.3%. The surgical site occurrence (SSO) rate was 32.4%. Recurrence rate was 11.5%. CONCLUSION This is the first systematic review and meta-analysis on the clinical outcomes of abdominal wall repair using biosynthetic mesh in contaminated-infected settings. The results show good results in patients at high risk of postoperative wound complications. The aim of this study is to add to the growing literature on biosynthetic mesh a picture of current literature evidence to help future researchers performing further studies on this topic.
Collapse
Affiliation(s)
- G Perrone
- Department of Emergency Surgery, Parma University Hospital, Parma, Italy
| | - M Giuffrida
- General Surgery Unit, Department of Medicine and Surgery, Parma University Hospital, Via A. Gramsci 14, 43126, Parma, Italy.
| | - E Bonati
- General Surgery Unit, Department of Medicine and Surgery, Parma University Hospital, Via A. Gramsci 14, 43126, Parma, Italy
| | - G L Petracca
- Department of Emergency Surgery, Parma University Hospital, Parma, Italy
| | - F Catena
- Department of Emergency and Trauma Surgey, Bufalini Trauma Center, Cesena, Italy
| |
Collapse
|
4
|
Linn JG, Mallico EJ, Doerhoff CR, Grantham DW, Washington RG. Evaluation of long-term performance of an intraperitoneal biomaterial in the treatment of ventral hernias. Surg Endosc 2022; 37:3455-3462. [PMID: 36550313 PMCID: PMC10156806 DOI: 10.1007/s00464-022-09803-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2022] [Accepted: 11/27/2022] [Indexed: 12/24/2022]
Abstract
BACKGROUND One-year device safety and clinical outcomes of ventral hernia repair with the GORE® SYNECOR Intraperitoneal Biomaterial, a hybrid composite mesh was evaluated. METHODS This retrospective, multicenter, case review analyzed device/procedure endpoints and patient-reported outcomes in patients treated for hernia repair ≥ 1 year from study enrollment. RESULTS Included were 459 patients (with 469 ventral hernias) with a mean age of 58 ± 15 years; 77.1% met Ventral Hernia Working Group 2 (VHWG2) classification. Mean hernia size was 18.9 cm2 and 57.3% of hernias were incisional. Laparoscopic or robotic approach was utilized in 95.4% of patients. Mesh location was intraperitoneal for 75.6% and bridging repair was performed in 57.3%. Procedure-related adverse events within 30-days occurred in 5.0% of patients and included surgical site infection (SSI), surgical site occurrence (SSO), ileus, readmission, and re-operation. Procedure-related SSI or SSO events were 3.8% through 12 months. SSO events requiring procedural intervention (SSOPI) were 2.6% through 24 months. Four patients (0.9%) had confirmed hernia recurrence through the study (the mean follow-up was 32-months, range 14-53 months). Subgroup comparisons were conducted for all type recurrence; only diabetes was found to be statistically significant (p = .0506). CONCLUSION In this analysis, ventral hernia repair with hybrid, composite mesh results in successful outcomes in most patients. This study represents a heterogeneous patient population undergoing repair using various approaches, mesh fixation, and mesh placement locations. These data appear to confirm long-term acceptable safety and device performance with a low rate of recurrence in a predominantly VHWG2 population.
Collapse
Affiliation(s)
- John G Linn
- NorthShore University Health System, 1000 Central St Suite 800, Evanston, IL, 60201, USA.
| | - Eric J Mallico
- Novant Health Bariatric Solutions-Salisbury, Salisbury, NC, USA
| | | | | | | |
Collapse
|
5
|
Alsaadi D, Stephens I, Simmons LO, Bucholc M, Sugrue M. Prophylactic onlay mesh at emergency laparotomy: promising early outcomes with long-acting synthetic resorbable mesh. ANZ J Surg 2022; 92:2218-2223. [PMID: 35912943 PMCID: PMC9540974 DOI: 10.1111/ans.17925] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2022] [Revised: 05/29/2022] [Accepted: 07/14/2022] [Indexed: 11/28/2022]
Abstract
Background Careful surgical strategy is paramount in balancing the prevention of fascial dehiscence, incisional hernia (IH) and fear of additional mesh‐related wound complications post‐laparotomy. This study aims to review early outcomes of patients undergoing an emergency laparotomy with prophylactic TIGR® mesh, used to reduce early fascial dehiscence and potential subsequent IH. Method A retrospective, ethically approved review of 24 consecutive patients undergoing prophylactic TIGR® mesh placement during emergency laparotomies by a single surgeon between January 2017 and June 2021 at a University Hospital. A standardized approach included onlay positioning of the mesh, small‐bite fascial closure, and a wound bundle. We recorded patient demographics, operative indications, findings, degree of peritonitis, postoperative complications, and mortality. Result The study included 24 patients; 16/24 (66.6%) were female and median age was 72.5 (range 31–86); 14/24 patients were ASA grade III or greater; 4/24 patients (16.6%) developed six complications and 3/6 occurred in a single patient. Complications included subphrenic abscess, seroma, intrabdominal hematoma, enterocutaneous fistula leading to deep wound infection and small bowel perforation. Five (20.8%) patients died in hospital; central venous catheter sepsis (n = 1), fungal septicaemia (n = 1) and multiorgan failure (n = 3). Surgical site infection and seroma rates were low, occurring in 2/24 patients (4% each). Conclusion This study has identified that prophylactic onlay mesh in patients undergoing an emergency laparotomy is not associated with significant wound infection or seroma when used with an active wound bundle. The wider use of TIGR® to prevent fascial dehiscence and potential long‐term IH prevention should be considered.
Collapse
Affiliation(s)
- Daniah Alsaadi
- Department of Surgery, Letterkenny University Hospital, Letterkenny, Ireland
| | - Ian Stephens
- Department of Surgery, Letterkenny University Hospital, Letterkenny, Ireland
| | - Lydia O Simmons
- Department of Surgery, Letterkenny University Hospital, Letterkenny, Ireland
| | - Magda Bucholc
- Intelligent Systems Research Centre, School of Computing, Engineering and Intelligent Systems, Ulster University, Derry, UK
| | - Michael Sugrue
- Department of Surgery, Letterkenny University Hospital, Letterkenny, Ireland.,Donegal Clinical Research Academy, Letterkenny University Hospital, Letterkenny, Ireland
| |
Collapse
|
6
|
Smith A, Slater K. Outcomes of biosynthetic absorbable mesh use in high risk CDC Class I ventral hernia repair: a single surgeon series. Hernia 2021; 26:97-108. [PMID: 34105003 DOI: 10.1007/s10029-021-02424-6] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2021] [Accepted: 04/30/2021] [Indexed: 12/01/2022]
Abstract
PURPOSE Biosynthetic absorbable meshes have emerged as suitable alternatives to permanent synthetic and biologic meshes in complex ventral hernia repair in contaminated wounds. Evidence regarding the use of these products in clean wounds is currently scant. This paper presents a large single surgeon series using GORE®BIO-A® (W.L. Gore & Associates, Newark, DE) (Bio-A) tissue reinforcement in high risk patients with predominantly CDC Class I wounds. METHODS Retrospective review of a prospectively maintained database of consecutive patients who underwent open ventral hernia repair with biosynthetic absorbable mesh was conducted. Ventral Hernia Working Group (VHWG) classification based on patient demographics and Centers for Disease Control (CDC) wound type were collected prospectively. All patients were followed up for a minimum of 12 months post-operatively. RESULTS 155 patients were included with a mean post-operative follow up of 29 months (range 12-62 months). Mean age was 61.8 years with an average BMI of 33.5 kg/m2. 147 patients (94.9%) were classified as VHWG 2 or 3 based on comorbidities or surgical field contamination. 69% (n = 107) of wounds were designated CDC Class I. Mean hernia size was 119.7cm2 with recurrent defects comprising 32.3% (n = 50). Retrorectus mesh repair was achieved in 84.5% of patients (n = 131). Post-operative wound events occurred in 19.3%. No mesh was explanted. Hernia recurrence rate was 9.0% with a mean time to recurrence of 14 months. There was no significant difference in recurrence rates between clean and contaminated wounds. CONCLUSION This study supports the use of Bio-A in high risk ventral hernias, demonstrating a safe and durable repair across all wound classes. Ongoing follow-up continues to monitor for late complications and recurrence.
Collapse
Affiliation(s)
- A Smith
- Greenslopes Private Hospital, Brisbane, QLD, Australia.
| | - K Slater
- Greenslopes Private Hospital, Brisbane, QLD, Australia.,Princess Alexandra Hospital, Brisbane, QLD, Australia
| |
Collapse
|