1
|
Xiang X, Zhang K, Qin Y, Ma X, Dai Y, Zhang X, Niu W, He P. Smart Cushions with Machine Learning-Enhanced Force Sensors for Pressure Injury Risk Assessment. ACS APPLIED MATERIALS & INTERFACES 2024; 16:38466-38477. [PMID: 38995996 DOI: 10.1021/acsami.4c05964] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 07/14/2024]
Abstract
Prolonged sitting can easily result in pressure injury (PI) for certain people who have had strokes or spinal cord injuries. There are not many methods available for tracking contact surface pressure and shear force to evaluate the PI risk. Here, we propose a smart cushion that uses two-dimensional force sensors (2D-FSs) to measure the pressure and shear force in the buttocks. A machine learning algorithm is then used to compute the shear stresses in the gluteal muscles, which helps to determine the PI risk. The 2D-FS consists of a ferroelectret coaxial sensor (FCS) unit placed atop a ferroelectret film sensor (FFS) unit, allowing it to detect both vertical and horizontal forces simultaneously. To characterize and calibrate, two experimental approaches are applied: one involves simultaneously applying two perpendicular forces, and one involves applying a single force. To separate the two forces, the 2D-FS is decoupled using a deep neural network technique. Multiple FCSs are embedded to form a smart cushion, and a genetic algorithm-optimized backpropagation neural network is proposed and trained to predict the shear strain in the buttocks to prevent PI. By tracking the danger of PI, the smart cushion based on 2D-FSs may be further connected with home-based intelligent care platforms to increase patient equality for spinal cord injury patients and lower the expense of nursing or rehabilitation care.
Collapse
Affiliation(s)
- Xinhao Xiang
- Shanghai Yangzhi Rehabilitation Hospital (Shanghai Sunshine Rehabilitation Center), School of Medicine, Tongji University, Shanghai 201619, China
| | - Ke Zhang
- Shanghai Yangzhi Rehabilitation Hospital (Shanghai Sunshine Rehabilitation Center), School of Medicine, Tongji University, Shanghai 201619, China
- Department of Rehabilitation Sciences, School of Medicine, Tongji University, Shanghai 200092, China
| | - Yi Qin
- Shanghai Key Laboratory of Special Artificial Microstructure Materials and Technology, School of Physics Science and Engineering, Tongji University, Shanghai 200092, China
| | - Xingchen Ma
- Shanghai Key Laboratory of Special Artificial Microstructure Materials and Technology, School of Physics Science and Engineering, Tongji University, Shanghai 200092, China
| | - Ying Dai
- School of Aerospace Engineering and Applied Mechanics, Tongji University, Shanghai ,200092, China
| | - Xiaoqing Zhang
- Shanghai Key Laboratory of Special Artificial Microstructure Materials and Technology, School of Physics Science and Engineering, Tongji University, Shanghai 200092, China
| | - Wenxin Niu
- Shanghai Yangzhi Rehabilitation Hospital (Shanghai Sunshine Rehabilitation Center), School of Medicine, Tongji University, Shanghai 201619, China
- Department of Rehabilitation Sciences, School of Medicine, Tongji University, Shanghai 200092, China
| | - Pengfei He
- School of Aerospace Engineering and Applied Mechanics, Tongji University, Shanghai ,200092, China
| |
Collapse
|
2
|
Fougeron N, Oddes Z, Ashkenazi A, Solav D. Identification of constitutive materials of bi-layer soft tissues from multimodal indentations. J Mech Behav Biomed Mater 2024; 155:106572. [PMID: 38754153 DOI: 10.1016/j.jmbbm.2024.106572] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2024] [Revised: 04/19/2024] [Accepted: 05/08/2024] [Indexed: 05/18/2024]
Abstract
The personalisation of finite element models is an important problem in the biomechanical fields where subject-specific analyses are fundamental, particularly in studying soft tissue mechanics. The personalisation includes the choice of the constitutive law of the model's material, as well as the choice of the material parameters. In vivo identification of the material properties of soft tissues is challenging considering the complex behaviour of soft tissues that are, among other things, non-linear hyperelastic and heterogeneous. Hybrid experimental-numerical methods combining in vivo indentations and inverse finite element analyses are common to identify these material parameters. Yet, the uniqueness and the uncertainty of the multi-material hyperelastic model have not been evaluated. This study presents a sensitivity analysis performed on synthetic indentation data to investigate the identification uncertainties of the material parameters in a bi-material thigh phantom. Synthetic numerical data, used to replace experimental measurements, considered several measurement modalities: indenter force and displacement, stereo-camera 3D digital image correlation of the indented surface, and ultrasound B-mode images. A finite element model of the indentation was designed with either Ogden-Moerman or Mooney-Rivlin constitutive laws for both materials. The parameters' identifiability (i.e. the possibility of converging to a unique parameter set within an acceptable margin of error) was assessed with various cost functions formulated using the different synthetic data sets. The results underline the need for multiple experimental modalities to reduce the uncertainty of the identified parameters. Additionally, the experimental error can impede the identification of a unique parameter set, and the cost function depends on the constitutive law. This study highlights the need for sensitivity analyses before the design of the experimental protocol. Such studies can also be used to define the acceptable range of errors in the experimental measurement. Eventually, the impact of the evaluated uncertainty of the identified parameters should be further investigated according to the purpose of the finite element modelling.
Collapse
Affiliation(s)
- Nolwenn Fougeron
- Faculty of Mechanical Engineering, Technion Institute of Technology, Haifa, Israel.
| | - Zohar Oddes
- Faculty of Mechanical Engineering, Technion Institute of Technology, Haifa, Israel
| | - Amit Ashkenazi
- Faculty of Mechanical Engineering, Technion Institute of Technology, Haifa, Israel
| | - Dana Solav
- Faculty of Mechanical Engineering, Technion Institute of Technology, Haifa, Israel
| |
Collapse
|
3
|
Ding K, Zhu Y, Zhang Y, Li Y, Wang H, Li J, Chen W, Zhang Q, Zhang Y. Proximal femoral bionic nail-a novel internal fixation system for the treatment of femoral neck fractures: a finite element analysis. Front Bioeng Biotechnol 2023; 11:1297507. [PMID: 38116197 PMCID: PMC10728673 DOI: 10.3389/fbioe.2023.1297507] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2023] [Accepted: 11/20/2023] [Indexed: 12/21/2023] Open
Abstract
Introduction: Currently, cannulated screws (CSs) and dynamic hip screws (DHSs) are widely used for the treatment of femoral neck fractures, but the postoperative complications associated with these internal fixations remain high. In response to this challenge, our team proposes a new approach involving triangular-supported fixation and the development of the proximal femoral bionic nail (PFBN). The primary objective of this study is to investigate the biomechanical differences among CSs, DHSs, and the PFBN in their capacity to stabilize femoral neck fractures. Methods: A normal proximal femur model was constructed according to the CT data of a normal healthy adult. A femoral neck fracture model was constructed and fixed with CSs, DHSs, and the PFBN to simulate the fracture fixation model. Abaqus 6.14 software was used to compare the biomechanical characters of the three fracture fixation models. Results: The maximum stresses and displacements of the normal proximal femur were 45.35 MPa and 2.83 mm, respectively. Under axial loading, the PFBN was more effective than DHSs and CSs in improving the stress concentration of the internal fixation and reducing the peak values of von Mises stress, maximum principal stress, and minimum principal stress. The PFBN fixation model exhibits superior overall and fracture section stability in comparison to both the DHS fixation model and the CS fixation model under axial loading. Notably, the maximum stress and peak displacement of the PFBN and bone were lower than those of the DHS and CS fixation models under bending and torsional loading. Conclusion: The PFBN shows considerable improvement in reducing stress concentration, propagating stress, and enhancing the overall stability in the femoral neck fracture fixation model compared to DHSs and CSs. These enhancements more closely correspond to the tissue structure and biomechanical characteristics of the proximal femur, demonstrating that the PFBN has great potential for therapeutic purposes in treating femoral neck fractures.
Collapse
Affiliation(s)
- Kai Ding
- Hebei Orthopaedic Clinical Research Center, Department of Orthopaedic Surgery, Hebei Medical University Third Hospital, Shijiazhuang, China
- Key Laboratory of Biomechanics of Hebei Province, Orthopaedic Research Institute of Hebei Province, Shijiazhuang, Hebei, China
- NHC Key Laboratory of Intelligent Orthopeadic Equipment, Hebei Medical University Third Hospital, Shijiazhuang, China
- Engineering Research Center of Orthopaedic Minimally Invasive Intelligent Equipment, Ministry of Education, Shijiazhuang, China
| | - Yanbin Zhu
- Hebei Orthopaedic Clinical Research Center, Department of Orthopaedic Surgery, Hebei Medical University Third Hospital, Shijiazhuang, China
- Key Laboratory of Biomechanics of Hebei Province, Orthopaedic Research Institute of Hebei Province, Shijiazhuang, Hebei, China
- NHC Key Laboratory of Intelligent Orthopeadic Equipment, Hebei Medical University Third Hospital, Shijiazhuang, China
- Engineering Research Center of Orthopaedic Minimally Invasive Intelligent Equipment, Ministry of Education, Shijiazhuang, China
| | - Yifan Zhang
- Hebei Orthopaedic Clinical Research Center, Department of Orthopaedic Surgery, Hebei Medical University Third Hospital, Shijiazhuang, China
- Key Laboratory of Biomechanics of Hebei Province, Orthopaedic Research Institute of Hebei Province, Shijiazhuang, Hebei, China
- NHC Key Laboratory of Intelligent Orthopeadic Equipment, Hebei Medical University Third Hospital, Shijiazhuang, China
- Engineering Research Center of Orthopaedic Minimally Invasive Intelligent Equipment, Ministry of Education, Shijiazhuang, China
| | - Yonglong Li
- Hebei Orthopaedic Clinical Research Center, Department of Orthopaedic Surgery, Hebei Medical University Third Hospital, Shijiazhuang, China
- Key Laboratory of Biomechanics of Hebei Province, Orthopaedic Research Institute of Hebei Province, Shijiazhuang, Hebei, China
- NHC Key Laboratory of Intelligent Orthopeadic Equipment, Hebei Medical University Third Hospital, Shijiazhuang, China
- Engineering Research Center of Orthopaedic Minimally Invasive Intelligent Equipment, Ministry of Education, Shijiazhuang, China
| | - Haicheng Wang
- Hebei Orthopaedic Clinical Research Center, Department of Orthopaedic Surgery, Hebei Medical University Third Hospital, Shijiazhuang, China
- Key Laboratory of Biomechanics of Hebei Province, Orthopaedic Research Institute of Hebei Province, Shijiazhuang, Hebei, China
- NHC Key Laboratory of Intelligent Orthopeadic Equipment, Hebei Medical University Third Hospital, Shijiazhuang, China
- Engineering Research Center of Orthopaedic Minimally Invasive Intelligent Equipment, Ministry of Education, Shijiazhuang, China
| | - Jiaxing Li
- Hebei Orthopaedic Clinical Research Center, Department of Orthopaedic Surgery, Hebei Medical University Third Hospital, Shijiazhuang, China
- Key Laboratory of Biomechanics of Hebei Province, Orthopaedic Research Institute of Hebei Province, Shijiazhuang, Hebei, China
- NHC Key Laboratory of Intelligent Orthopeadic Equipment, Hebei Medical University Third Hospital, Shijiazhuang, China
- Engineering Research Center of Orthopaedic Minimally Invasive Intelligent Equipment, Ministry of Education, Shijiazhuang, China
| | - Wei Chen
- Hebei Orthopaedic Clinical Research Center, Department of Orthopaedic Surgery, Hebei Medical University Third Hospital, Shijiazhuang, China
- Key Laboratory of Biomechanics of Hebei Province, Orthopaedic Research Institute of Hebei Province, Shijiazhuang, Hebei, China
- NHC Key Laboratory of Intelligent Orthopeadic Equipment, Hebei Medical University Third Hospital, Shijiazhuang, China
- Engineering Research Center of Orthopaedic Minimally Invasive Intelligent Equipment, Ministry of Education, Shijiazhuang, China
| | - Qi Zhang
- Hebei Orthopaedic Clinical Research Center, Department of Orthopaedic Surgery, Hebei Medical University Third Hospital, Shijiazhuang, China
- Key Laboratory of Biomechanics of Hebei Province, Orthopaedic Research Institute of Hebei Province, Shijiazhuang, Hebei, China
- NHC Key Laboratory of Intelligent Orthopeadic Equipment, Hebei Medical University Third Hospital, Shijiazhuang, China
- Engineering Research Center of Orthopaedic Minimally Invasive Intelligent Equipment, Ministry of Education, Shijiazhuang, China
| | - Yingze Zhang
- Hebei Orthopaedic Clinical Research Center, Department of Orthopaedic Surgery, Hebei Medical University Third Hospital, Shijiazhuang, China
- Key Laboratory of Biomechanics of Hebei Province, Orthopaedic Research Institute of Hebei Province, Shijiazhuang, Hebei, China
- NHC Key Laboratory of Intelligent Orthopeadic Equipment, Hebei Medical University Third Hospital, Shijiazhuang, China
- Engineering Research Center of Orthopaedic Minimally Invasive Intelligent Equipment, Ministry of Education, Shijiazhuang, China
- Chinese Academy of Engineering, Bejing, China
| |
Collapse
|
4
|
Raju V, Koorata PK. Computational assessment on the impact of collagen fiber orientation in cartilages on healthy and arthritic knee kinetics/kinematics. Med Eng Phys 2023; 117:103997. [PMID: 37331751 DOI: 10.1016/j.medengphy.2023.103997] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2022] [Revised: 05/15/2023] [Accepted: 05/17/2023] [Indexed: 06/20/2023]
Abstract
BACKGROUND The inhomogeneous distribution of collagen fiber in cartilage can substantially influence the knee kinematics. This becomes vital for understanding the mechanical response of soft tissues, and cartilage deterioration including osteoarthritis (OA). Though the conventional computational models consider geometrical heterogeneity along with fiber reinforcements in the cartilage model as material heterogeneity, the influence of fiber orientation on knee kinetics and kinematics is not fully explored. This work examines how the collagen fiber orientation in the cartilage affects the healthy (intact knee) and arthritic knee response over multiple gait activities like running and walking. METHODS A 3D finite element knee joint model is used to compute the articular cartilage response during the gait cycle. A fiber-reinforced porous hyper elastic (FRPHE) material is used to model the soft tissue. A split-line pattern is used to implement the fiber orientation in femoral and tibial cartilage. Four distinct intact cartilage models and three OA models are simulated to assess the impact of the orientation of collagen fibers in a depth wise direction. The cartilage models with fibers oriented in parallel, perpendicular, and inclined to the articular surface are investigated for multiple knee kinematics and kinetics. FINDINGS The comparison of models with fiber orientation parallel to articulating surface for walking and running gait has the highest elastic stress and fluid pressure compared with inclined and perpendicular fiber-oriented models. Also, the maximum contact pressure is observed to be higher in the case of intact models during the walking cycle than for OA models. In contrast, the maximum contact pressure is higher during running in OA models than in intact models. Additionally, parallel-oriented models produce higher maximum stresses and fluid pressure for walking and running gait than proximal-distal-oriented models. Interestingly, during the walking cycle, the maximum contact pressure with intact models is approximately three times higher than on OA models. In contrast, the OA models exhibit higher contact pressure during the running cycle. INTERPRETATION Overall, the study indicates that collagen orientation is crucial for tissue responsiveness. This investigation provides insights into the development of tailored implants.
Collapse
Affiliation(s)
- Vaishakh Raju
- Applied Solid Mechanics Laboratory, Department of Mechanical Engineering, National Institute of Technology Karnataka, Surathkal, 575025, India
| | - Poornesh Kumar Koorata
- Applied Solid Mechanics Laboratory, Department of Mechanical Engineering, National Institute of Technology Karnataka, Surathkal, 575025, India.
| |
Collapse
|
5
|
Peng L, Wu Y, Lakshminarayanan K, Zhang A, Gan Y, Li Y, Yao Y. The relationship between shear wave velocity in transverse carpal ligament and carpal tunnel pressure: A finite element analysis. Med Eng Phys 2023; 116:103995. [PMID: 37230698 DOI: 10.1016/j.medengphy.2023.103995] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2022] [Revised: 05/12/2023] [Accepted: 05/14/2023] [Indexed: 05/27/2023]
Abstract
Elevated carpal tunnel pressure in carpal tunnel syndrome (CTS) patients is one of the major causes of nerve damage but cannot be measured non-invasively. This study proposed to use shear wave velocity (SWV) in the transverse carpal ligament (TCL) to measure the surrounding carpal tunnel pressure. The relationship between the carpal tunnel pressure and the SWV in the TCL was investigated through a subject-specific carpal tunnel finite element model reconstrued by MRI imaging. Parametric analysis was conducted to study the effect of TCL Young's modulus and carpal tunnel pressure on the TCL SWV. The SWV in TCL was found to be strongly dependent on the carpal tunnel pressure and TCL Young's modulus. The calculated SWV ranged from 8.0 m/s to 22.6 m/s under a combination of carpal tunnel pressure (0-200 mmHg) and TCL Young's modulus (1.1-11 MPa). An empirical equation was used to fit the relationship between the SWV in TCL and carpal tunnel pressure, with TCL Young's modulus as a confounding factor. The equation proposed in this study provided an approach to estimate carpal tunnel pressure by measuring the SWV in the TCL for a potential non-invasive diagnosis of CTS and may shed light on the mechanical nerve damage mechanism.
Collapse
Affiliation(s)
- Linjing Peng
- School of Biomedical Engineering, Shanghai Jiao Tong University, 1954 Huashan Road, Shanghai, 200030, China; Engineering Research Center of Digital Medicine and Clinical Translation, Ministry of Education, Shanghai Jiao Tong University, 1954 Huashan Road, Shanghai, 200030, China
| | - Yu Wu
- School of Biomedical Engineering, Shanghai Jiao Tong University, 1954 Huashan Road, Shanghai, 200030, China; Olin College of Engineering, 1000 Olin Way, Needham, 02492, US
| | - Kishor Lakshminarayanan
- Department of Sensors and Biomedical Engineering, Vellore Institute of Technology, Ranipet Katpadi Road Vellore, 632 014, Tamil Nadu, India
| | - Aili Zhang
- School of Biomedical Engineering, Shanghai Jiao Tong University, 1954 Huashan Road, Shanghai, 200030, China
| | - Yaokai Gan
- Engineering Research Center of Digital Medicine and Clinical Translation, Ministry of Education, Shanghai Jiao Tong University, 1954 Huashan Road, Shanghai, 200030, China; Department of Orthopedics, Shanghai Ninth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, 639 Zhizaoju Road, Shanghai, China, 200011
| | - Yiming Li
- Department of Orthopedics, Shanghai Ninth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, 639 Zhizaoju Road, Shanghai, China, 200011
| | - Yifei Yao
- School of Biomedical Engineering, Shanghai Jiao Tong University, 1954 Huashan Road, Shanghai, 200030, China; Engineering Research Center of Digital Medicine and Clinical Translation, Ministry of Education, Shanghai Jiao Tong University, 1954 Huashan Road, Shanghai, 200030, China.
| |
Collapse
|
6
|
Peng L, Yu L, Jia J, Gan Y, Ding A, Xiong P, Zhao Y, Yao Y. The effect of thickness and elastic modulus of the anterior talofibular ligament on anterior ankle joint stiffness: A subject-specific finite element study. Front Bioeng Biotechnol 2023; 11:1175347. [PMID: 37180042 PMCID: PMC10166853 DOI: 10.3389/fbioe.2023.1175347] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2023] [Accepted: 04/10/2023] [Indexed: 05/15/2023] Open
Abstract
Ankle sprain is a frequent type of sports injury leading to lateral ligament injury. The anterior talofibular ligament (ATFL) is a primary ligamentous stabilizer of the ankle joint and typically the most vulnerable ligament injured in a lateral ankle sprain (LAS). This study aimed to quantitively investigate the effect of the thickness and elastic modulus of ATFL on anterior ankle joint stiffness (AAJS) by developing nine subject-specific finite element (FE) models under acute injury, chronic injury, and control conditions of ATFL. A 120 N forward force was applied at the posterior calcaneus leading to an anterior translation of the calcaneus and talus to simulate the anterior drawer test (ADT). In the results, the ratio of the forward force to the talar displacement was used to assess the AAJS, which increased by 5.85% in the acute group and decreased by 19.78% in the chronic group, compared to those of the control group. An empirical equation described the relationship between AAJS, thickness, and elastic modulus (R-square 0.98). The equation proposed in this study provided an approach to quantify AAJS and revealed the effect of the thickness and the elastic modulus of ATFL on ankle stability, which may shed light on the potential diagnosis of lateral ligament injury.
Collapse
Affiliation(s)
- Linjing Peng
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
- Engineering Research Center of Digital Medicine of the Ministry of Education, Shanghai Jiao Tong University, Shanghai, China
| | - Lu Yu
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
- Engineering Research Center of Digital Medicine of the Ministry of Education, Shanghai Jiao Tong University, Shanghai, China
| | - Jingyi Jia
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
- Engineering Research Center of Digital Medicine of the Ministry of Education, Shanghai Jiao Tong University, Shanghai, China
| | - Yaokai Gan
- Engineering Research Center of Digital Medicine of the Ministry of Education, Shanghai Jiao Tong University, Shanghai, China
- Department of Orthopedics, Shanghai Ninth People’s Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| | - Angang Ding
- Department of Ultrasound, Shanghai Ninth People’s Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| | - Ping Xiong
- Department of Ultrasound, Shanghai Ninth People’s Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| | - Yichen Zhao
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Yifei Yao
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
- Engineering Research Center of Digital Medicine of the Ministry of Education, Shanghai Jiao Tong University, Shanghai, China
| |
Collapse
|
7
|
Jia J, Gong S, Zhang A, Jiang L, Yao Y. Stiffening of the gluteal muscle increased the intramuscular stress: An in-silico implication of deep tissue injury. Heliyon 2023; 9:e13459. [PMID: 36816309 PMCID: PMC9929311 DOI: 10.1016/j.heliyon.2023.e13459] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2022] [Revised: 01/27/2023] [Accepted: 01/31/2023] [Indexed: 02/05/2023] Open
Abstract
Objectives Deep tissue injury is a common form of pressure ulcers in muscle tissues under bony prominences caused by sustained pressure or shear, which has a great impact on patients with restricted mobility such as spinal cord injury. Frequent spasms in spinal cord injury patients featured by muscle stiffening may be one of the factors leading to deep tissue injury. The purpose of this study was to investigate the relationship between the gluteal muscle shear modulus and intramuscular compressive/shear stress/strain. Methods A semi-3D finite element model of the human buttock was established using COMSOL software and the acquired biomechanical data were analyzed through Pearson correlation and Spearman correlation. Results Results showed that the compressive stress, strain energy density, and average von Mises stress increased with the increase of the gluteal muscle shear modulus. Conclusion These results may indicate muscle stiffening caused by muscle spasms could lead to higher deep tissue injury development risk as well as shed light on effective treatments for relieving muscular sclerosis mechanically.
Collapse
Affiliation(s)
- Jingyi Jia
- School of Biomedical Engineering, Med-X Research Institute, Shanghai Jiao Tong University, 1954 Huashan Road, Shanghai 200030, China,Engineering Research Center of Digital Medicine and Clinical Translation, Ministry of Education, 1954 Huashan Road, Shanghai Jiao Tong University, Shanghai 200030, China
| | - Shengbo Gong
- School of Biomedical Engineering, Med-X Research Institute, Shanghai Jiao Tong University, 1954 Huashan Road, Shanghai 200030, China,Engineering Research Center of Digital Medicine and Clinical Translation, Ministry of Education, 1954 Huashan Road, Shanghai Jiao Tong University, Shanghai 200030, China
| | - Aili Zhang
- School of Biomedical Engineering, Med-X Research Institute, Shanghai Jiao Tong University, 1954 Huashan Road, Shanghai 200030, China
| | - Liping Jiang
- Nursing Department, Xinhua Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, 1665 Kongjiang Road, Shanghai 200092, China
| | - Yifei Yao
- School of Biomedical Engineering, Med-X Research Institute, Shanghai Jiao Tong University, 1954 Huashan Road, Shanghai 200030, China,Engineering Research Center of Digital Medicine and Clinical Translation, Ministry of Education, 1954 Huashan Road, Shanghai Jiao Tong University, Shanghai 200030, China,Corresponding author. School of Biomedical Engineering, Med-X Research Institute, Shanghai Jiao Tong University, 1954 Huashan Road, Shanghai 200030, China.
| |
Collapse
|