Sweedo A, Wise LM, Roka-Moiia Y, Arce FT, Saavedra SS, Sheriff J, Bluestein D, Slepian MJ, Purdy JG. Shear-Mediated Platelet Activation is Accompanied by Unique Alterations in Platelet Release of Lipids. Cell Mol Bioeng 2021; 14:597-612. [PMID: 34900013 PMCID: PMC8630256 DOI: 10.1007/s12195-021-00692-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2021] [Accepted: 07/16/2021] [Indexed: 10/20/2022] Open
Abstract
INTRODUCTION Platelet activation by mechanical means such as shear stress exposure, is a vital driver of thrombotic risk in implantable blood-contacting devices used in the treatment of heart failure. Lipids are essential in platelets activation and have been studied following biochemical activation. However, little is known regarding lipid alterations occurring with mechanical shear-mediated platelet activation. METHODS Here, we determined if shear-activation of platelets induced lipidome changes that differ from those associated with biochemically-mediated platelet activation. We performed high-resolution lipidomic analysis on purified platelets from four healthy human donors. For each donor, we compared the lipidome of platelets that were non-activated or activated by shear, ADP, or thrombin treatment. RESULTS We found that shear activation altered cell-associated lipids and led to the release of lipids into the extracellular environment. Shear-activated platelets released 21 phospholipids and sphingomyelins at levels statistically higher than platelets activated by biochemical stimulation. CONCLUSIONS We conclude that shear-mediated activation of platelets alters the basal platelet lipidome. Further, these alterations differ and are unique in comparison to the lipidome of biochemically activated platelets. Many of the released phospholipids contained an arachidonic acid tail or were phosphatidylserine lipids, which have known procoagulant properties. Our findings suggest that lipids released by shear-activated platelets may contribute to altered thrombosis in patients with implanted cardiovascular therapeutic devices. SUPPLEMENTARY INFORMATION The online version contains supplementary material available at 10.1007/s12195-021-00692-x.
Collapse
Affiliation(s)
- Alice Sweedo
- Department of Biomedical Engineering, University of Arizona, Tucson, AZ USA
| | - Lisa M. Wise
- Department of Immunobiology, University of Arizona, 1656 E. Mabel Street, PO Box 245221, Tucson, AZ 85724 USA
- BIO5 Institute, University of Arizona, Tucson, AZ USA
| | - Yana Roka-Moiia
- Department of Medicine, Sarver Heart Center, University of Arizona, Tucson, AZ USA
| | - Fernando Teran Arce
- Department of Biomedical Engineering, University of Arizona, Tucson, AZ USA
- Department of Medicine, Sarver Heart Center, University of Arizona, Tucson, AZ USA
| | - S. Scott Saavedra
- Department of Biomedical Engineering, University of Arizona, Tucson, AZ USA
- BIO5 Institute, University of Arizona, Tucson, AZ USA
- Department of Chemistry and Biochemistry, University of Arizona, Tucson, AZ USA
| | - Jawaad Sheriff
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY USA
| | - Danny Bluestein
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY USA
| | - Marvin J. Slepian
- Department of Biomedical Engineering, University of Arizona, Tucson, AZ USA
- BIO5 Institute, University of Arizona, Tucson, AZ USA
- Department of Medicine, Sarver Heart Center, University of Arizona, Tucson, AZ USA
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY USA
- Department of Material Sciences and Engineering, University of Arizona, Tucson, AZ USA
| | - John G. Purdy
- Department of Immunobiology, University of Arizona, 1656 E. Mabel Street, PO Box 245221, Tucson, AZ 85724 USA
- BIO5 Institute, University of Arizona, Tucson, AZ USA
| |
Collapse
|
2
|
Sheriff J, Wang P, Zhang P, Zhang Z, Deng Y, Bluestein D. In Vitro Measurements of Shear-Mediated Platelet Adhesion Kinematics as Analyzed through Machine Learning. Ann Biomed Eng 2021; 49:3452-3464. [PMID: 33973127 DOI: 10.1007/s10439-021-02790-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2021] [Accepted: 05/03/2021] [Indexed: 12/30/2022]
Abstract
Platelet adhesion to blood vessel walls in shear flow is essential to initiating the blood coagulation cascade and prompting clot formation in vascular disease processes and prosthetic cardiovascular devices. Validation of predictive adhesion kinematics models at the single platelet level is difficult due to gaps in high resolution, dynamic morphological data or a mismatch between simulation and experimental parameters. Gel-filtered platelets were perfused at 30 dyne/cm2 in von Willebrand Factor (vWF)-coated microchannels, with flipping platelets imaged at high spatial and temporal resolution. A semi-unsupervised learning system (SULS), consisting of a series of convolutional neural networks, was used to segment platelet geometry, which was compared with expert-analyzed images. Resulting time-dependent rotational angles were smoothed with wavelet-denoising and shifting techniques to characterize the rotational period and quantify flipping kinematics. We observed that flipping platelets do not follow the previously-modeled modified Jefferey orbit, but are characterized by a longer lift-off and shorter reattachment period. At the juncture of the two periods, rotational velocity approached 257.48 ± 13.31 rad/s. Our SULS approach accurately segmented large numbers of moving platelet images to identify distinct adhesive kinematic characteristics which may further validate the physical accuracy of individual platelet motion in multiscale models of shear-mediated thrombosis.
Collapse
Affiliation(s)
- Jawaad Sheriff
- Department of Biomedical Engineering, T08-50 Health Sciences Center, Stony Brook University, Stony Brook, NY, 11794-8084, USA
| | - Peineng Wang
- Department of Biomedical Engineering, T08-50 Health Sciences Center, Stony Brook University, Stony Brook, NY, 11794-8084, USA
| | - Peng Zhang
- Department of Applied Mathematics and Statistics, Stony Brook University, Stony Brook, NY, USA
| | - Ziji Zhang
- Department of Applied Mathematics and Statistics, Stony Brook University, Stony Brook, NY, USA
| | - Yuefan Deng
- Department of Applied Mathematics and Statistics, Stony Brook University, Stony Brook, NY, USA
| | - Danny Bluestein
- Department of Biomedical Engineering, T08-50 Health Sciences Center, Stony Brook University, Stony Brook, NY, 11794-8084, USA.
| |
Collapse
|
3
|
Roka-Moiia Y, Ammann KR, Miller-Gutierrez S, Sweedo A, Palomares D, Italiano J, Sheriff J, Bluestein D, Slepian MJ. Shear-mediated platelet activation in the free flow II: Evolving mechanobiological mechanisms reveal an identifiable signature of activation and a bi-directional platelet dyscrasia with thrombotic and bleeding features. J Biomech 2021; 123:110415. [PMID: 34052772 DOI: 10.1016/j.jbiomech.2021.110415] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2021] [Accepted: 03/03/2021] [Indexed: 01/17/2023]
Abstract
Shear-mediated platelet activation (SMPA) in the "free flow" is the net result of a range of cell mechanobiological mechanisms. Previously, we outlined three main groups of mechanisms including: 1) mechano-destruction - i.e. additive platelet (membrane) damage; 2) mechano-activation - i.e. activation of shear-sensitive ion channels and pores; and 3) mechano-transduction - i.e. "outside-in" signaling via a range of transducers. Here, we report on recent advances since our original report which describes additional features of SMPA. A clear "signature" of SMPA has been defined, allowing differentiation from biochemically-mediated activation. Notably, SMPA is characterized by mitochondrial dysfunction, platelet membrane eversion, externalization of anionic phospholipids, and increased thrombin generation on the platelet surface. However, SMPA does not lead to integrin αIIbβ3 activation or P-selectin exposure due to platelet degranulation, as is commonly observed in biochemical activation. Rather, downregulation of GPIb, αIIbβ3, and P-selectin surface expression is evident. Furthermore, SMPA is accompanied by a decrease in overall platelet size coupled with a concomitant, progressive increase in microparticle generation. Shear-ejected microparticles are highly enriched in GPIb and αIIbβ3. These observations indicate the enhanced diffusion, migration, or otherwise dispersion of platelet adhesion receptors to membrane zones, which are ultimately shed as receptor-rich PDMPs. The pathophysiological consequence of this progressive shear accumulation phenomenon is an associated dyscrasia of remaining platelets - being both reduced in size and less activatable via biochemical means - a tendency to favor bleeding, while concomitantly shed microparticles are highly prothrombotic and increase the tendency for thrombosis in both local and systemic milieu. These mechanisms and observations offer direct clinical utility in allowing measurement and guidance of the net balance of platelet driven events in patients with implanted cardiovascular therapeutic devices.
Collapse
Affiliation(s)
- Yana Roka-Moiia
- Departments of Medicine and Biomedical Engineering, Sarver Heart Center, University of Arizona, Tucson, AZ 85721, United States; Arizona Center for Accelerated Biomedical Innovation, University of Arizona, Tucson, AZ 85721, United States
| | - Kaitlyn R Ammann
- Departments of Medicine and Biomedical Engineering, Sarver Heart Center, University of Arizona, Tucson, AZ 85721, United States; Arizona Center for Accelerated Biomedical Innovation, University of Arizona, Tucson, AZ 85721, United States
| | - Samuel Miller-Gutierrez
- Departments of Medicine and Biomedical Engineering, Sarver Heart Center, University of Arizona, Tucson, AZ 85721, United States; Arizona Center for Accelerated Biomedical Innovation, University of Arizona, Tucson, AZ 85721, United States
| | - Alice Sweedo
- Departments of Medicine and Biomedical Engineering, Sarver Heart Center, University of Arizona, Tucson, AZ 85721, United States; Arizona Center for Accelerated Biomedical Innovation, University of Arizona, Tucson, AZ 85721, United States
| | - Daniel Palomares
- Departments of Medicine and Biomedical Engineering, Sarver Heart Center, University of Arizona, Tucson, AZ 85721, United States; Arizona Center for Accelerated Biomedical Innovation, University of Arizona, Tucson, AZ 85721, United States
| | - Joseph Italiano
- Department of Medicine, Harvard Medical School, Boston, MA 02115, United States
| | - Jawaad Sheriff
- Department of Biomedical Engineering, Stony Brook University, NY 11794, United States
| | - Danny Bluestein
- Department of Biomedical Engineering, Stony Brook University, NY 11794, United States
| | - Marvin J Slepian
- Departments of Medicine and Biomedical Engineering, Sarver Heart Center, University of Arizona, Tucson, AZ 85721, United States; Department of Biomedical Engineering, Stony Brook University, NY 11794, United States; Arizona Center for Accelerated Biomedical Innovation, University of Arizona, Tucson, AZ 85721, United States.
| |
Collapse
|
4
|
A predictive multiscale model for simulating flow-induced platelet activation: Correlating in silico results with in vitro results. J Biomech 2021; 117:110275. [PMID: 33529943 DOI: 10.1016/j.jbiomech.2021.110275] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2020] [Accepted: 01/16/2021] [Indexed: 11/21/2022]
Abstract
Flow-induced platelet activation prompts complex filopodial formation. Continuum methods fail to capture such molecular-scale mechanisms. A multiscale numerical model was developed to simulate this activation process, where a Dissipative Particle Dynamics (DPD) model of viscous blood flow is interfaced with a Coarse Grained Molecular Dynamics (CGMD) platelet model. Embedded in DPD blood flow, the macroscopic dynamic stresses are interactively transferred to the CGMD model, inducing intra-platelet associated events. The platelets activate by a biomechanical transductive linkage chain and dynamically change their shape in response. The models are fully coupled via a hybrid-potential interface and multiple time-stepping (MTS) schemes for handling the disparity between the spatiotemporal scales. Cumulative hemodynamic stresses that may lead to platelet activation are mapped on the surface membrane and simultaneously transmitted to the cytoplasm and cytoskeleton. Upon activation, the flowing platelets lose their quiescent discoid shape and evolve by forming filopodia. The model predictions were validated by a set of in vitro experiments, Platelets were exposed to various combinations of shear stresses and durations in our programmable hemodynamic shearing device (HSD). Their shape change was measured at multiple time points using scanning electron microscopy (SEM). The CGMD model parameters were fine-tuned by interrogating a parameter space established in these experiments. Segmentation of the SEM imaging streams was conducted by a deep machine learning system. This model can be further employed to simulate shear mediated platelet activation thrombosis initiation and to study the effects of modulating platelet properties to enhance their shear resistance via mechanotransduction pathways.
Collapse
|
5
|
Wu Y, Fu A, Yossifon G. Active Particle Based Selective Transport and Release of Cell Organelles and Mechanical Probing of a Single Nucleus. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2020; 16:e1906682. [PMID: 32363783 DOI: 10.1002/smll.201906682] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/18/2019] [Revised: 03/27/2020] [Accepted: 03/27/2020] [Indexed: 06/11/2023]
Abstract
Self-propelling micromotors are emerging as a promising microscale tool for single-cell analysis. The authors have recently shown that the field gradients necessary to manipulate matter via dielectrophoresis can be induced at the surface of a polarizable active ("self-propelling") metallo-dielectric Janus particle (JP) under an externally applied electric field, acting essentially as a mobile floating microelectrode. Here, the application of the mobile floating microelectrode to trap and transport cell organelles in a selective and releasable manner is successfully extended. This selectivity is driven by the different dielectrophoretic (DEP) potential wells on the JP surface that is controlled by the frequency of the electric field, along with the hydrodynamic shearing and size of the trapped organelles. Such selective and directed loading enables purification of targeted organelles of interest from a mixed biological sample while their dynamic release enables their harvesting for further analysis such as gene/RNA sequencing or proteomics. Moreover, the electro-deformation of the trapped nucleus is shown to be in correlation with the DEP force and hence, can act as a promising label-free biomechanical marker. Hence, the active carrier constitutes an important and novel ex vivo platform for manipulation and mechanical probing of subcellular components of potential for single cell analysis.
Collapse
Affiliation(s)
- Yue Wu
- Faculty of Mechanical Engineering, Micro- and Nano-Fluidics Laboratory, Technion-Israel Institute of Technology, Haifa, 32000, Israel
| | - Afu Fu
- Technion Integrated Cancer Center, The Rappaport Faculty of Medicine and Research Institute, Technion-Israel Institute of Technology, Haifa, 3525433, Israel
| | - Gilad Yossifon
- Faculty of Mechanical Engineering, Micro- and Nano-Fluidics Laboratory, Technion-Israel Institute of Technology, Haifa, 32000, Israel
| |
Collapse
|
6
|
Morshed A, Dutta P, Kim MJ. Electrophoretic transport and dynamic deformation of bio-vesicles. Electrophoresis 2019; 40:2584-2591. [PMID: 30993726 PMCID: PMC6718350 DOI: 10.1002/elps.201900025] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2019] [Revised: 03/21/2019] [Accepted: 04/01/2019] [Indexed: 11/06/2022]
Abstract
Study of the deformation dynamics of cells and other sub-micron vesicles, such as virus and neurotransmitter vesicles are necessary to understand their functional properties. This mechanical characterization can be done by submerging the vesicle in a fluid medium and deforming it with a controlled electric field, which is known as electrodeformation. Electrodeformation of biological and artificial lipid vesicles is directly influenced by the vesicle and surrounding media properties and geometric factors. The problem is compounded when the vesicle is naturally charged, which creates electrophoretic forcing on the vesicle membrane. We studied the electrodeformation and transport of charged vesicles immersed in a fluid media under the influence of a DC electric field. The electric field and fluid-solid interactions are modeled using a hybrid immersed interface-immersed boundary technique. Model results are verified with experimental observations for electric field driven translocation of a virus through a nanopore sensor. Our modeling results show interesting changes in deformation behavior with changing electrical properties of the vesicle and the surrounding media. Vesicle movement due to electrophoresis can also be characterized by the change in local conductivity, which can serve as a potential sensing mechanism for electrodeformation experiments in solid-state nanopore setups.
Collapse
Affiliation(s)
- Adnan Morshed
- School of Mechanical and Materials Engineering, Washington State University, Pullman, WA 99164
| | - Prashanta Dutta
- School of Mechanical and Materials Engineering, Washington State University, Pullman, WA 99164
| | - Min Jun Kim
- Department of Mechanical Engineering, Southern Methodist University, Dallas, TX, 75275
| |
Collapse
|
7
|
Kang DH, Kim K, Kim YJ. An anti-clogging method for improving the performance and lifespan of blood plasma separation devices in real-time and continuous microfluidic systems. Sci Rep 2018; 8:17015. [PMID: 30451905 PMCID: PMC6242854 DOI: 10.1038/s41598-018-35235-4] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2018] [Accepted: 10/27/2018] [Indexed: 11/11/2022] Open
Abstract
On-chip blood plasma separators using microfluidic channels are typically developed as disposable devices for short-term use only because blood cells tend to clog the microchannels, limiting their application in real-time and continuous systems. In this study, we propose an anti-clogging method. We applied dielectrophoresis to prevent microchannel clogging in a plasma separator that can be used over long periods for real-time and continuous monitoring. Prior to applying the anti-clogging method, the blood plasma separator stopped working after 4 h. In contrast, by manipulating the separator with the new anti-clogging method at a voltage of 20 V, it continued working in a long-term experiment for 12 h without performance deterioration or an increase in cell loss. Two critical performance parameters of the manipulated separator, the purity efficiency and the plasma yield, were 97.23 ± 5.43% and 38.95 ± 9.34%, respectively, at 20 V after 15 min. Interestingly, the two performance parameters did not decrease during the long-term experiment. Hence, the blood plasma separator with the anti-clogging method is an interesting device for use in real-time and continuous blood plasma separation systems because of its consistent performance and improved lifespan.
Collapse
Affiliation(s)
- Dong-Hyun Kang
- School of Mechanical Engineering, Yonsei University, 50, Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea
| | - Kyongtae Kim
- School of Mechanical Engineering, Yonsei University, 50, Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea
| | - Yong-Jun Kim
- School of Mechanical Engineering, Yonsei University, 50, Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea.
| |
Collapse
|
8
|
Teng Y, Zhu K, Xiong C, Huang J. Electrodeformation-Based Biomechanical Chip for Quantifying Global Viscoelasticity of Cancer Cells Regulated by Cell Cycle. Anal Chem 2018; 90:8370-8378. [DOI: 10.1021/acs.analchem.8b00584] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Affiliation(s)
| | - Kui Zhu
- Beijing Advanced Innovation Center for Food Nutrition and Human Health, College of Veterinary Medicine, China Agricultural University, Beijing 100193, China
| | | | | |
Collapse
|
9
|
Abstract
We envision that electrodeformation of biological cells through dielectrophoresis as a new technique to elucidate the mechanistic details underlying membrane failure by electrical and mechanical stresses. Here we demonstrate the full control of cellular uniaxial deformation and tensile recovery in biological cells via amplitude-modified electric field at radio frequency by an interdigitated electrode array in microfluidics. Transient creep and cyclic experiments were performed on individually tracked human erythrocytes. Observations of the viscoelastic-to-viscoplastic deformation behavior and the localized plastic deformations in erythrocyte membranes suggest that electromechanical stress results in irreversible membrane failure. Examples of membrane failure can be separated into different groups according to the loading scenarios: mechanical stiffening, physical damage, morphological transformation from discocyte to echinocyte, and whole cell lysis. These results show that this technique can be potentially utilized to explore membrane failure in erythrocytes affected by other pathophysiological processes.
Collapse
Affiliation(s)
- E Du
- Correspondence: ; Tel.: +1-561-297-3441
| | | | | |
Collapse
|
10
|
Valerio L, Sheriff J, Tran PL, Brengle W, Redaelli A, Fiore GB, Pappalardo F, Bluestein D, Slepian MJ. Routine clinical anti-platelet agents have limited efficacy in modulating hypershear-mediated platelet activation associated with mechanical circulatory support. Thromb Res 2017; 163:162-171. [PMID: 29428715 DOI: 10.1016/j.thromres.2017.12.001] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2017] [Revised: 11/03/2017] [Accepted: 12/02/2017] [Indexed: 11/25/2022]
Abstract
INTRODUCTION Continuous flow ventricular assist devices (cfVADs) continue to be limited by thrombotic complications associated with disruptive flow patterns and supraphysiologic shear stresses. Patients are prescribed complex antiplatelet therapies, which do not fully prevent recurrent thromboembolic events. This is partially due to limited data on antiplatelet efficacy under cfVAD-associated shear conditions. MATERIALS AND METHODS We investigated the efficacy of antiplatelet drugs directly acting on three pathways: (1) cyclooxygenase (aspirin), (2) phosphodiesterase (dipyridamole, pentoxifylline, cilostazol), and (3) glycoprotein IIb-IIIa (eptifibatide). Gel-filtered platelets treated with these drugs were exposed for 10min to either constant shear stresses (30dyne/cm2 and 70dyne/cm2) or dynamic shear stress profiles extracted from simulated platelet trajectories through a cfVAD (Micromed DeBakey). Platelet activation state (PAS) was measured using a modified prothrombinase-based assay, with drug efficacy quantified based on PAS reduction compared to untreated controls. RESULTS AND CONCLUSIONS Significant PAS reduction was observed for all drugs after exposure to 30dyne/cm2 constant shear stress, and all drugs but dipyridamole after exposure to the 30th percentile shear stress waveform of the cfVAD. However, only cilostazol was significantly effective after 70dyne/cm2 constant shear stress exposure, though no significant reduction was observed upon exposure to median shear stress conditions in the cfVAD. These results, coupled with the persistence of reported clinical thrombotic complication, suggest the need for the development of new classes of drugs that are especially designed to mitigate thrombosis in cfVAD patients, while reducing or eliminating the risk of bleeding.
Collapse
Affiliation(s)
- Lorenzo Valerio
- Department of Electronics, Information, and Bioengineering, Politecnico di Milano, Milan, Italy; Department of Cardiothoracic Anesthesia and Intensive Care, Istituto Scientifico San Raffaele, Milan, Italy
| | - Jawaad Sheriff
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY, USA
| | - Phat L Tran
- Department of Biomedical Engineering, Sarver Heart Center, University of Arizona, Tucson, AZ, USA
| | - William Brengle
- Department of Biomedical Engineering, Sarver Heart Center, University of Arizona, Tucson, AZ, USA
| | - Alberto Redaelli
- Department of Electronics, Information, and Bioengineering, Politecnico di Milano, Milan, Italy
| | - Gianfranco B Fiore
- Department of Electronics, Information, and Bioengineering, Politecnico di Milano, Milan, Italy
| | - Federico Pappalardo
- Department of Cardiothoracic Anesthesia and Intensive Care, Istituto Scientifico San Raffaele, Milan, Italy
| | - Danny Bluestein
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY, USA
| | - Marvin J Slepian
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY, USA; Department of Biomedical Engineering, Sarver Heart Center, University of Arizona, Tucson, AZ, USA; Department of Medicine, Sarver Heart Center, University of Arizona, Tucson, AZ, USA.
| |
Collapse
|
11
|
Bai G, Li Y, Chu HK, Wang K, Tan Q, Xiong J, Sun D. Characterization of biomechanical properties of cells through dielectrophoresis-based cell stretching and actin cytoskeleton modeling. Biomed Eng Online 2017; 16:41. [PMID: 28376803 PMCID: PMC5381122 DOI: 10.1186/s12938-017-0329-8] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2016] [Accepted: 03/16/2017] [Indexed: 02/02/2023] Open
Abstract
Background Cytoskeleton is a highly dynamic network that helps to maintain the rigidity of a cell, and the mechanical properties of a cell are closely related to many cellular functions. This paper presents a new method to probe and
characterize cell mechanical properties through dielectrophoresis (DEP)-based cell stretching manipulation and actin cytoskeleton modeling. Methods Leukemia NB4 cells were used as cell line, and changes in their biological properties were examined after chemotherapy treatment with doxorubicin (DOX). DEP-integrated microfluidic chip was utilized as a low-cost and efficient tool to study the deformability of cells. DEP forces used in cell stretching were first evaluated through computer simulation, and the results were compared with modeling equations and with the results of optical stretching (OT) experiments. Structural parameters were then extracted by fitting the experimental data into the actin cytoskeleton model, and the underlying mechanical properties of the cells were subsequently characterized. Results The DEP forces generated under different voltage inputs were calculated and the results from different approaches demonstrate good approximations to the force estimation. Both DEP and OT stretching experiments confirmed that DOX-treated NB4 cells were stiffer than the untreated cells. The structural parameters extracted from the model and the confocal images indicated significant change in actin network after DOX treatment. Conclusion The proposed DEP method combined with actin cytoskeleton modeling is a simple engineering tool to characterize the mechanical properties of cells.
Collapse
Affiliation(s)
- Guohua Bai
- Key Laboratory of Instrumentation Science and Dynamic Measurement, Ministry of Education, North University of China, Room 418, Building No. 14, No. 3 Xueyuan Road, Taiyuan, 030051, Shanxi, China
| | - Ying Li
- Department of Mechanical and Biomedical Engineering, City University of Hong Kong, 83 Tat Chee Avenue, Kowloon Tong, Hong Kong, SAR of China
| | - Henry K Chu
- Department of Mechanical Engineering, The Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong, SAR of China
| | - Kaiqun Wang
- Department of Biomedical Engineering, College of Mechanics, Taiyuan University of Technology, No. 79, West Yingze Street, Taiyuan, 030024, Shanxi, China
| | - Qiulin Tan
- Key Laboratory of Instrumentation Science and Dynamic Measurement, Ministry of Education, North University of China, Room 418, Building No. 14, No. 3 Xueyuan Road, Taiyuan, 030051, Shanxi, China
| | - Jijun Xiong
- Key Laboratory of Instrumentation Science and Dynamic Measurement, Ministry of Education, North University of China, Room 418, Building No. 14, No. 3 Xueyuan Road, Taiyuan, 030051, Shanxi, China
| | - Dong Sun
- Department of Mechanical and Biomedical Engineering, City University of Hong Kong, 83 Tat Chee Avenue, Kowloon Tong, Hong Kong, SAR of China.
| |
Collapse
|
12
|
Zhang P, Zhang L, Slepian MJ, Deng Y, Bluestein D. A multiscale biomechanical model of platelets: Correlating with in-vitro results. J Biomech 2016; 50:26-33. [PMID: 27894676 DOI: 10.1016/j.jbiomech.2016.11.019] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2016] [Accepted: 11/02/2016] [Indexed: 10/20/2022]
Abstract
Using dissipative particle dynamics (DPD) combined with coarse grained molecular dynamics (CGMD) approaches, we developed a multiscale deformable platelet model to accurately describe the molecular-scale intra-platelet constituents and biomechanical properties of platelets in blood flow. Our model includes the platelet bilayer membrane, cytoplasm and an elaborate elastic cytoskeleton. Correlating numerical simulations with published in-vitro experiments, we validated the biorheology of the cytoplasm, the elastic response of membrane to external stresses, and the stiffness of the cytoskeleton actin filaments, resulting in an accurate representation of the molecular-level biomechanical microstructures of platelets. This enabled us to study the mechanotransduction process of the hemodynamic stresses acting onto the platelet membrane and transmitted to these intracellular constituents. The platelets constituents continuously deform in response to the flow induced stresses. To the best of our knowledge, this is the first molecular-scale platelet model that can be used to accurately predict platelets activation mechanism leading to thrombus formation in prosthetic cardiovascular devices and in vascular disease processes. This model can be further employed to study the effects of novel therapeutic approaches of modulating platelet properties to enhance their shear resistance via mechanotransduction pathways.
Collapse
Affiliation(s)
- Peng Zhang
- Biomedical Engineering Department, Stony Brook University, NY 11794, USA
| | - Li Zhang
- Applied Mathematics Department, Stony Brook University, NY 11794, USA
| | - Marvin J Slepian
- Biomedical Engineering Department, Stony Brook University, NY 11794, USA; Departments of Medicine and Biomedical Engineering, University of Arizona, Tucson, AZ 85721, USA
| | - Yuefan Deng
- Applied Mathematics Department, Stony Brook University, NY 11794, USA
| | - Danny Bluestein
- Biomedical Engineering Department, Stony Brook University, NY 11794, USA.
| |
Collapse
|
13
|
Slepian MJ, Sheriff J, Hutchinson M, Tran P, Bajaj N, Garcia JGN, Scott Saavedra S, Bluestein D. Shear-mediated platelet activation in the free flow: Perspectives on the emerging spectrum of cell mechanobiological mechanisms mediating cardiovascular implant thrombosis. J Biomech 2016; 50:20-25. [PMID: 27887727 DOI: 10.1016/j.jbiomech.2016.11.016] [Citation(s) in RCA: 50] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2016] [Accepted: 11/02/2016] [Indexed: 12/13/2022]
Abstract
Shear-mediated platelet activation (SMPA) is central in thrombosis of implantable cardiovascular therapeutic devices. Despite the morbidity and mortality associated with thrombosis of these devices, our understanding of mechanisms operative in SMPA, particularly in free flowing blood, remains limited. Herein we present and discuss a range of emerging mechanisms for consideration for "free flow" activation under supraphysiologic shear. Further definition and manipulation of these mechanisms will afford opportunities for novel pharmacologic and mechanical strategies to limit SMPA and enhance overall implant device safety.
Collapse
Affiliation(s)
- Marvin J Slepian
- Departments of Medicine and Biomedical Engineering, University of Arizona, Tucson, AZ 85721, United States; Department of Biomedical Engineering, Stony Brook University, NY 11794, United States.
| | - Jawaad Sheriff
- Department of Biomedical Engineering, Stony Brook University, NY 11794, United States
| | - Marcus Hutchinson
- Departments of Medicine and Biomedical Engineering, University of Arizona, Tucson, AZ 85721, United States
| | - Phat Tran
- Departments of Medicine and Biomedical Engineering, University of Arizona, Tucson, AZ 85721, United States
| | - Naing Bajaj
- Departments of Medicine and Biomedical Engineering, University of Arizona, Tucson, AZ 85721, United States
| | - Joe G N Garcia
- Departments of Medicine and Biomedical Engineering, University of Arizona, Tucson, AZ 85721, United States
| | - S Scott Saavedra
- Departments of Chemistry and Biochemistry, University of Arizona, Tucson, AZ 85721, United States
| | - Danny Bluestein
- Department of Biomedical Engineering, Stony Brook University, NY 11794, United States
| |
Collapse
|
14
|
Flow-Induced Damage to Blood Cells in Aortic Valve Stenosis. Ann Biomed Eng 2016; 44:2724-36. [PMID: 27048168 PMCID: PMC9924290 DOI: 10.1007/s10439-016-1577-7] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2015] [Accepted: 02/23/2016] [Indexed: 12/11/2022]
Abstract
Valvular hemolysis and thrombosis are common complications associated with stenotic heart valves. This study aims to determine the extent to which hemodynamics induce such traumatic events. The viscous shear stress downstream of a severely calcified bioprosthetic valve was evaluated via in vitro 2D particle image velocimetry measurements. The blood cell membrane response to the measured stresses was then quantified using 3D immersed-boundary computational simulations. The shear stress level at the boundary layer of the jet flow formed downstream of the valve orifice was observed to reach a maximum of 1000-1700 dyn/cm(2), which was beyond the threshold values reported for platelet activation (100-1000 dyn/cm(2)) and within the range of thresholds reported for red blood cell (RBC) damage (1000-2000 dyn/cm(2)). Computational simulations demonstrated that the resultant tensions at the RBC membrane surface were unlikely to cause instant rupture, but likely to lead to membrane plastic failure. The resultant tensions at the platelet surface were also calculated and the potential damage was discussed. It was concluded that although shear-induced thrombotic trauma is very likely in stenotic heart valves, instant hemolysis is unlikely and the shear-induced damage to RBCs is mostly subhemolytic.
Collapse
|
15
|
Marom G, Bluestein D. Lagrangian methods for blood damage estimation in cardiovascular devices--How numerical implementation affects the results. Expert Rev Med Devices 2016; 13:113-22. [PMID: 26679833 DOI: 10.1586/17434440.2016.1133283] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
This paper evaluated the influence of various numerical implementation assumptions on predicting blood damage in cardiovascular devices using Lagrangian methods with Eulerian computational fluid dynamics. The implementation assumptions that were tested included various seeding patterns, stochastic walk model, and simplified trajectory calculations with pathlines. Post processing implementation options that were evaluated included single passage and repeated passages stress accumulation and time averaging. This study demonstrated that the implementation assumptions can significantly affect the resulting stress accumulation, i.e., the blood damage model predictions. Careful considerations should be taken in the use of Lagrangian models. Ultimately, the appropriate assumptions should be considered based the physics of the specific case and sensitivity analysis, similar to the ones presented here, should be employed.
Collapse
Affiliation(s)
- Gil Marom
- a Department of Biomedical Engineering , Stony Brook University , Stony Brook , NY , USA
| | - Danny Bluestein
- a Department of Biomedical Engineering , Stony Brook University , Stony Brook , NY , USA
| |
Collapse
|
16
|
Matsuoka H. ELECTROCHEMISTRY 2016; 84:41-49. [DOI: 10.5796/electrochemistry.84.41] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
|