1
|
Whittington JR, Ghahremani T, Friski A, Hamilton A, Magann EF. Window to the Womb: Amniotic Fluid and Postnatal Outcomes. Int J Womens Health 2023; 15:117-124. [PMID: 36756186 PMCID: PMC9900144 DOI: 10.2147/ijwh.s378020] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2022] [Accepted: 01/18/2023] [Indexed: 02/04/2023] Open
Abstract
Amniotic fluid volumes are tightly regulated, and amniotic fluid derangement can indicate maternal complications or fetal abnormalities. Ultrasound estimate of amniotic fluid provides a tool to evaluate the maternal-fetal-placental interface in real-time. Oligohydramnios and polyhydramnios are associated with adverse maternal and neonatal outcomes. Oligohydramnios is associated with adverse maternal and neonatal outcomes including cesarean delivery, operative vaginal delivery, induction of labor, postpartum hemorrhage, small for gestational age neonate, intrauterine demise, neonatal death, NICU admission, and APGAR less than 7 at. 5 minutes of life Polyhydramnios is associated with adverse outcomes including cesarean delivery, induction of labor, placental abruption, shoulder dystocia, cord prolapse, postpartum hemorrhage, intrauterine fetal demise, NICU admission, neonatal death, APGAR less than 7 at 5 minutes of life, large for gestational age neonate, and respiratory distress syndrome. Therefore, Amniotic fluid should be evaluated when maternal or fetal well-being is in question.
Collapse
Affiliation(s)
- Julie R Whittington
- Women’s Health Department, Naval Medical Readiness and Training Center Portsmouth, Portsmouth, VA, USA,Correspondence: Julie R Whittington, Women’s Health Department, Naval Readiness and Training Command Portsmouth, 620 John Paul Jones Circle, Portsmouth, VA, 23321, USA, Tel +1-979-848-9665, Email
| | - Taylor Ghahremani
- Department of OB/GYN, University of Arkansas for Medical Sciences, Little Rock, AR, USA
| | - Andrew Friski
- Women’s Health Department, Naval Medical Readiness and Training Center Portsmouth, Portsmouth, VA, USA
| | - Andrew Hamilton
- Women’s Health Department, Naval Medical Readiness and Training Center Portsmouth, Portsmouth, VA, USA
| | - Everett F Magann
- Women’s Health Department, Naval Medical Readiness and Training Center Portsmouth, Portsmouth, VA, USA
| |
Collapse
|
2
|
Souza SCS, Kim K, Dingwall-Harvey ALJ, Fakhraei R, Liao Y, Gaudet LM. Evaluating the correlation between amniotic fluid volume and estimated fetal weight in healthy pregnant women. J Perinat Med 2022; 50:1096-1099. [PMID: 35589556 DOI: 10.1515/jpm-2022-0104] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/23/2022] [Accepted: 04/25/2022] [Indexed: 11/15/2022]
Abstract
OBJECTIVES The establishment of cut-offs for normal amniotic fluid volume (AFV) is valuable to predict perinatal outcomes. However, the most common methods to measure AFV are not accurate enough. It is important to understand factors that may be able to increase the accuracy of the calculation of AFV cut-off values. The objective of this study was to verify the correlation between AFV and estimated fetal weight (EFW). METHODS Records from almost 7,000 patients between 2012 and 2017 were accessed through hospital databases. The AFV measurements included in our analysis were obtained using the maximum vertical pocket technique. RESULTS AFV was positively correlated with EFW in the overall, male and female samples; however, the magnitude of the association was small (0.1 CONCLUSIONS The incorporation of EFW together with other factors (e.g., gestational age, fetus sex) may increase the accuracy of the AFV cut-offs calculation and, ultimately, reduce morbidity.
Collapse
Affiliation(s)
- Sara C S Souza
- OMNI Research Group, Clinical Epidemiology Program, Ottawa Hospital Research Institute, Ottawa, Canada
| | - Katherine Kim
- OMNI Research Group, Clinical Epidemiology Program, Ottawa Hospital Research Institute, Ottawa, Canada
| | | | - Romina Fakhraei
- OMNI Research Group, Clinical Epidemiology Program, Ottawa Hospital Research Institute, Ottawa, Canada
- School of Epidemiology and Public Health, University of Ottawa, Ottawa, Canada
| | - Yan Liao
- OMNI Research Group, Clinical Epidemiology Program, Ottawa Hospital Research Institute, Ottawa, Canada
| | - Laura M Gaudet
- OMNI Research Group, Clinical Epidemiology Program, Ottawa Hospital Research Institute, Ottawa, Canada
- School of Epidemiology and Public Health, University of Ottawa, Ottawa, Canada
- Department of Obstetrics and Gynecology, Kingston Health Sciences Center, Kingston, Canada
- Department of Obstetrics and Gynecology, Queen's University, Kingston, Canada
| |
Collapse
|
3
|
Gordon Z, Fattal-Valevski A, Elad D, Jaffa AJ. Controlled amnioreduction for twin-to-twin transfusion syndrome. Ther Adv Reprod Health 2022; 16:26334941221080727. [PMID: 35369393 PMCID: PMC8969010 DOI: 10.1177/26334941221080727] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2021] [Accepted: 01/12/2022] [Indexed: 12/29/2022] Open
Abstract
Background: Twin-to-twin transfusion syndrome (TTTS) is a severe condition causing preterm delivery, fetal death, and neurodevelopmental disorders. This study presents a data-based controlled amnioreduction (AR) protocol composed of sequential amniodrainage in treatment of TTTS. Methods: A total of 18 procedures were performed in 11 TTTS pregnancies at 17 to 34 weeks of gestation. The amniotic pressure was measured along with sequential removal of the amniotic fluid, 500 mL each step. The umbilical artery systolic/diastolic (S/D) ratio for each twin was measured pre- and post-AR. Long-term neurodevelopmental outcomes of all TTTS survivors were evaluated from parental answers to a phone survey. Results: The amniotic pressure decreased exponentially with the increased volume of removed amniotic fluid until a plateau was obtained. Changes of the S/D ratio between pre- and post-AR procedure did not reveal a clear tendency. The survival rate was 86.4% although 91% of all twins were at Quintero stage III. Long-term neurodevelopment outcomes in the 19 surviving twins were 68.4% optimal, 26.3% suboptimal, and 5.3% abnormal. Conclusion: The controlled AR procedure resulted in a relatively high rate of twin survival with favorable long-term neurodevelopment outcomes.
Collapse
Affiliation(s)
- Zoya Gordon
- Ultrasound Unit in Obstetrics and Gynecology, Lis Maternity Hospital, Tel Aviv Sourasky Medical Center, 6 Weizmann, Tel Aviv 64239, Israel
| | - Aviva Fattal-Valevski
- Pediatric Neurology Institute, Dana-Dwek Children’s Hospital, Tel Aviv Sourasky Medical Center, Tel Aviv, Israel
| | - David Elad
- Department of Biomedical Engineering, Faculty of Engineering, Tel Aviv University, Tel Aviv, Israel
| | - Ariel J. Jaffa
- Ultrasound Unit in Obstetrics and Gynecology, Lis Maternity Hospital, Tel Aviv Sourasky Medical Center, Tel Aviv, Israel; Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
| |
Collapse
|
4
|
Neamtu RI, Craina M, Dahma G, Popescu AV, Erimescu AG, Citu I, Dobrescu A, Horhat FG, Vulcanescu DD, Gorun F, Bernad ES, Motoc A, Citu IC. Heavy metal ion concentration in the amniotic fluid of preterm and term pregnancies from two cities with different industrial output. Exp Ther Med 2022; 23:111. [PMID: 34970334 PMCID: PMC8713173 DOI: 10.3892/etm.2021.11034] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2021] [Accepted: 11/10/2021] [Indexed: 11/19/2022] Open
Abstract
The growth and development of the fetus is a complex phenomenon that can be influenced by several variables. High quantities of heavy metal ions in the amniotic fluid have been linked to poor health, especially in industrial, polluted and poor areas. The aim of the present study was to assess the differences in the concentration of these ions between preterm (weeks 15-37) and term pregnancies (starting at week 37). Another objective was to compare pregnancies from two cities with different industry levels. Two sample lots from two Romanian cities were analyzed. A total of 100 patients from Timisoara were compared with 60 from Petrosani, a heavy industry city in Romania. Demographic data were collected, and amniocentesis was performed on all women. Lead (Pb), copper (Cu), nickel (Ni), cadmium (Cd), arsenic (As), iron (Fe) and zinc (Zn) concentrations were assessed. Descriptive and analytical statistics were performed using the Mann-Whitney U test for non-parametric data and the Fisher's exact test for categorical data. In addition, categorical data was represented graphically. In the Timisoara cohort, the differences in heavy metal concentrations between preterm and term pregnancies were not statistically significant. In the Petrosani cohort, however, the concentrations of Zn (P=0.02606) and Cd (P=0.01512) were higher in preterm than in term pregnancies. When comparing the two cohorts as a whole, the concentration of Pb (P=0.04513), Cd (P=0.00002), As (P=0.03027) and Zn (P<0.00001) were higher in the patients from Petrosani than in those from Timisoara. Only Cu concentrations were higher in the Timisoara cohort (P<0.00001). The concentrations of Ni (P=0.78150) and Fe (P=0.44540) did not differ statistically. Thus, amniocentesis is an important diagnostic and exploratory tool in determining differences in the concentrations of elements such as heavy metal ions. Research over a longer period of time should be carried out to examine the relation between heavy metal ions concentration and possible postnatal health outcomes.
Collapse
Affiliation(s)
- Radu Ionut Neamtu
- Department of Obstetrics-Gynecology and Neonatology, 'Victor Babes' University of Medicine and Pharmacy, 300041 Timisoara, Romania
| | - Marius Craina
- Department of Obstetrics-Gynecology and Neonatology, 'Victor Babes' University of Medicine and Pharmacy, 300041 Timisoara, Romania
| | - George Dahma
- Department of Obstetrics-Gynecology and Neonatology, 'Victor Babes' University of Medicine and Pharmacy, 300041 Timisoara, Romania
| | - Alin Viorel Popescu
- Department of Obstetrics-Gynecology and Neonatology, 'Victor Babes' University of Medicine and Pharmacy, 300041 Timisoara, Romania
| | - Adelina Geanina Erimescu
- Department of Obstetrics-Gynecology and Neonatology, 'Victor Babes' University of Medicine and Pharmacy, 300041 Timisoara, Romania
| | - Ioana Citu
- Department of Internal Medicine I, 'Victor Babes' University of Medicine and Pharmacy, 300041 Timisoara, Romania
| | - Amadeus Dobrescu
- Department of Surgery, 'Victor Babes' University of Medicine and Pharmacy, 300041 Timisoara, Romania
| | - Florin George Horhat
- Multidisciplinary Research Center on Antimicrobial Resistance (Multi-Rez), Microbiology Department, 'Victor Babes' University of Medicine and Pharmacy, 300041 Timisoara, Romania.,Clinical Laboratory, 'Louis Turcanu' Emergency Hospital for Children, 300011 Timisoara, Romania
| | - Dan Dumitru Vulcanescu
- Multidisciplinary Research Center on Antimicrobial Resistance (Multi-Rez), Microbiology Department, 'Victor Babes' University of Medicine and Pharmacy, 300041 Timisoara, Romania.,Clinical Laboratory, 'Louis Turcanu' Emergency Hospital for Children, 300011 Timisoara, Romania
| | - Florin Gorun
- Department of Obstetrics-Gynecology and Neonatology, 'Victor Babes' University of Medicine and Pharmacy, 300041 Timisoara, Romania
| | - Elena Silvia Bernad
- Department of Internal Medicine I, 'Victor Babes' University of Medicine and Pharmacy, 300041 Timisoara, Romania
| | - Andrei Motoc
- Department of Obstetrics-Gynecology and Neonatology, 'Victor Babes' University of Medicine and Pharmacy, 300041 Timisoara, Romania.,Department of Anatomy and Embryology, 'Victor Babes' University of Medicine and Pharmacy, 300041 Timisoara, Romania
| | - Ioan Cosmin Citu
- Department of Obstetrics-Gynecology and Neonatology, 'Victor Babes' University of Medicine and Pharmacy, 300041 Timisoara, Romania
| |
Collapse
|
5
|
Kirshenbaum M, Ziv-Baran T, Katorza E. Amniotic fluid index measurements in the second and third trimester and correlation to fetal biometric parameters - new reference based on a big retrospective data. J Matern Fetal Neonatal Med 2021; 35:8176-8180. [PMID: 34470112 DOI: 10.1080/14767058.2021.1965981] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
INTRODUCTION Estimation of amniotic fluid volume (AFV) is part of routine obstetric sonography which reflects maternal-fetal circulation efficiency, fetal hemodynamic status, and a parameter for predicting adverse neonatal outcome. Fetal weight is positively correlated with AFV. Therefore, our objective is to provide a new nomogram of AFV indices and to evaluate the relation between AFV and fetal biometric parameters. MATERIALS AND METHODS Retrospective cohort study between 2011 and 2018, at a large tertiary medical center. Data were collected from medical charts of prenatal sonographic evaluation of normal pregnancies, including routine estimation of AFV by using amniotic fluid index (AFI). Generalized estimating equations model was used to study the association between AFI, gestational age and fetal biometric parameters. Centiles were calculated using the Generalized Additive Models for Location, Scale, and Shape model. Box-Cox-t distribution and smoothing splines were used. RESULTS Analysis included 28,650 pregnancies. From 25 to 41 weeks gestation, the median and fifth percentile AFI gradually decreased from 174 (IQR 157-193) to 138 mm (IQR 107-173) and from 125 to 68 mm, respectively. The change in the 95th percentile was less significant, ranging around 230 mm throughout pregnancy. Multivariate regression analysis demonstrated a significant correlation between AFI and maternal body mass index (B = -0.147; CI = -0.27 to -0.02), gestational age (B = -11.8; CI = -12.5 to -11.4), estimated fetal weight (EFW) (B = 0.05; CI = 0.049-0.053) and abdominal circumference (AC) (B = 0.94; CI = 0.95-1). There was no correlation between AFI and other fetal biometric parameters. CONCLUSIONS We suggest new AFI indices of singleton pregnancies. We found a positive correlation between AFI and EFW and AC.
Collapse
Affiliation(s)
- Michal Kirshenbaum
- Department of Obstetrics and Gynecology, Sheba Medical Center, Ramat-Gan, Israel.,Sackler School of Medicine, Tel-Aviv University, Tel-Aviv, Israel
| | - Tomer Ziv-Baran
- Department of Epidemiology and Preventive Medicine, School of Public Health, Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
| | - Eldad Katorza
- Department of Obstetrics and Gynecology, Sheba Medical Center, Ramat-Gan, Israel.,Sackler School of Medicine, Tel-Aviv University, Tel-Aviv, Israel
| |
Collapse
|
6
|
Hughes DS, Magann EF, Whittington JR, Wendel MP, Sandlin AT, Ounpraseuth ST. Accuracy of the Ultrasound Estimate of the Amniotic Fluid Volume (Amniotic Fluid Index and Single Deepest Pocket) to Identify Actual Low, Normal, and High Amniotic Fluid Volumes as Determined by Quantile Regression. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2020; 39:373-378. [PMID: 31423632 DOI: 10.1002/jum.15116] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/22/2019] [Revised: 07/29/2019] [Accepted: 07/30/2019] [Indexed: 06/10/2023]
Abstract
OBJECTIVES To identify abnormal amniotic fluid volumes (AFVs), normal volumes must be determined. Multiple statistical methods are used to define normal amniotic fluid curves; however, quantile regression (QR) is gaining favor. We reanalyzed ultrasound estimates in identifying oligohydramnios, normal fluid, and polyhydramnios using normal volumes calculated by QR. METHODS Data from 506 dye-determined or directly measured AFVs along with ultrasound estimates were analyzed. Each was classified as low, normal, or high for both the single deepest pocket (SDP) and amniotic fluid index (AFI). A weighted κ statistic was used to assess the level of agreement between the AFI and SDP compared to actual AFVs by QR. RESULTS The overall level of agreement for the AFI was fair (κ = 0.26), and that for the SDP was slight (κ = 0.19). Although not statistically significant (P = .792), the positive predictive value to classify a low volume using the AFI was lower compared to the SDP (35% vs 43%). The positive predictive value for a high volume was higher using the AFI compared to the SDP (55% versus 31%) but not statistically significant. The missed-call rate for high-volume identification by the SDP versus AFI was statistically significant (odds ratio, 5.5; 95% confidence interval, 2.04-14.97). The missed-call rate for low-volume identification by the AFI versus SDP was not statistically significant (odds ratio, 3.3; 95% confidence interval, 0.96-11.53). CONCLUSIONS Both the AFI and SDP identify actual normal AFVs by QR, with sensitivity higher than 90%. The SDP is superior for identification of oligohydramnios, and the AFI superior for identification of polyhydramnios.
Collapse
Affiliation(s)
- Dawn S Hughes
- Department of Obstetrics and Gynecology, University of Arkansas for Medical Sciences, Little Rock, Arkansas, USA
| | - Everett F Magann
- Department of Obstetrics and Gynecology, University of Arkansas for Medical Sciences, Little Rock, Arkansas, USA
| | - Julie R Whittington
- Department of Obstetrics and Gynecology, University of Arkansas for Medical Sciences, Little Rock, Arkansas, USA
| | - Michael P Wendel
- Department of Obstetrics and Gynecology, University of Arkansas for Medical Sciences, Little Rock, Arkansas, USA
| | - Adam T Sandlin
- Department of Obstetrics and Gynecology, University of Arkansas for Medical Sciences, Little Rock, Arkansas, USA
| | - Songthip T Ounpraseuth
- Department of Biostatistics, University of Arkansas for Medical Sciences, Little Rock, Arkansas, USA
| |
Collapse
|
7
|
Dallmann A, Ince I, Meyer M, Willmann S, Eissing T, Hempel G. Gestation-Specific Changes in the Anatomy and Physiology of Healthy Pregnant Women: An Extended Repository of Model Parameters for Physiologically Based Pharmacokinetic Modeling in Pregnancy. Clin Pharmacokinet 2018; 56:1303-1330. [PMID: 28401479 DOI: 10.1007/s40262-017-0539-z] [Citation(s) in RCA: 74] [Impact Index Per Article: 12.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
BACKGROUND In the past years, several repositories for anatomical and physiological parameters required for physiologically based pharmacokinetic modeling in pregnant women have been published. While providing a good basis, some important aspects can be further detailed. For example, they did not account for the variability associated with parameters or were lacking key parameters necessary for developing more detailed mechanistic pregnancy physiologically based pharmacokinetic models, such as the composition of pregnancy-specific tissues. OBJECTIVES The aim of this meta-analysis was to provide an updated and extended database of anatomical and physiological parameters in healthy pregnant women that also accounts for changes in the variability of a parameter throughout gestation and for the composition of pregnancy-specific tissues. METHODS A systematic literature search was carried out to collect study data on pregnancy-related changes of anatomical and physiological parameters. For each parameter, a set of mathematical functions was fitted to the data and to the standard deviation observed among the data. The best performing functions were selected based on numerical and visual diagnostics as well as based on physiological plausibility. RESULTS The literature search yielded 473 studies, 302 of which met the criteria to be further analyzed and compiled in a database. In total, the database encompassed 7729 data. Although the availability of quantitative data for some parameters remained limited, mathematical functions could be generated for many important parameters. Gaps were filled based on qualitative knowledge and based on physiologically plausible assumptions. CONCLUSION The presented results facilitate the integration of pregnancy-dependent changes in anatomy and physiology into mechanistic population physiologically based pharmacokinetic models. Such models can ultimately provide a valuable tool to investigate the pharmacokinetics during pregnancy in silico and support informed decision making regarding optimal dosing regimens in this vulnerable special population.
Collapse
Affiliation(s)
- André Dallmann
- Department of Pharmaceutical and Medical Chemistry, Clinical Pharmacy, Westfälische Wilhelm-University Münster, Münster, Germany
| | - Ibrahim Ince
- ET-TD-ET Systems Pharmacology CV, Bayer AG, Leverkusen, Germany.
| | - Michaela Meyer
- DD-CS Clinical Pharmacometrics, Bayer AG, Wuppertal, Germany
| | - Stefan Willmann
- DD-CS Clinical Pharmacometrics, Bayer AG, Wuppertal, Germany
| | - Thomas Eissing
- ET-TD-ET Systems Pharmacology CV, Bayer AG, Leverkusen, Germany
| | - Georg Hempel
- Department of Pharmaceutical and Medical Chemistry, Clinical Pharmacy, Westfälische Wilhelm-University Münster, Münster, Germany
| |
Collapse
|
8
|
Ounpraseuth ST, Magann EF, Spencer HJ, Rabie NZ, Sandlin AT. Normal amniotic fluid volume across gestation: Comparison of statistical approaches in 1190 normal amniotic fluid volumes. J Obstet Gynaecol Res 2017; 43:1122-1131. [DOI: 10.1111/jog.13332] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2016] [Revised: 02/01/2017] [Accepted: 02/24/2017] [Indexed: 12/01/2022]
Affiliation(s)
- Songthip T. Ounpraseuth
- Department of Biostatistics; University of Arkansas for the Medical Sciences; Little Rock Arkansas USA
| | - Everett F. Magann
- Department of Obstetrics and Gynecology; University of Arkansas for the Medical Sciences; Little Rock Arkansas USA
| | - Horace J. Spencer
- Department of Biostatistics; University of Arkansas for the Medical Sciences; Little Rock Arkansas USA
| | - Nader Z. Rabie
- Department of Obstetrics and Gynecology; University of Arkansas for the Medical Sciences; Little Rock Arkansas USA
| | - Adam T. Sandlin
- Department of Obstetrics and Gynecology; University of Arkansas for the Medical Sciences; Little Rock Arkansas USA
| |
Collapse
|
9
|
Hughes DS, Magann EF. Antenatal fetal surveillance "Assessment of the AFV". Best Pract Res Clin Obstet Gynaecol 2016; 38:12-23. [PMID: 27756534 DOI: 10.1016/j.bpobgyn.2016.08.004] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2016] [Revised: 06/10/2016] [Accepted: 08/08/2016] [Indexed: 11/29/2022]
Abstract
The evaluation of amniotic fluid volume (AFV) is an established part of the antenatal surveillance of pregnancies at risk for an adverse pregnancy outcome. The two most commonly used ultrasound techniques to estimate AFV are the amniotic fluid index (AFI) and the single deepest pocket (SDP). Four studies have defined normal AFVs, and although their normal volumes have similarities, there are also differences primarily due to the statistical methodology used in each study. Dye-determined AFV correlates with ultrasound estimates for normal fluid volumes but correlates poorly for oligohydramnios and polyhydramnios. The addition of color Doppler in estimating AFV leads to the overdiagnosis of oligohydramnios. Neither the AFI nor the SDP is superior in identifying oligohydramnios, but the SDP is a better measurement choice as the use of AFI increases the diagnosis rate of oligohydramnios and labor inductions without an improvement in pregnancy outcomes.
Collapse
Affiliation(s)
- Dawn S Hughes
- Department of Obstetrics and Gynecology, University of Arkansas for Medical Sciences, Little Rock, AR, USA
| | - Everett F Magann
- Department of Obstetrics and Gynecology, University of Arkansas for Medical Sciences, Little Rock, AR, USA.
| |
Collapse
|
10
|
|
11
|
|
12
|
Amniotic fluid volume in normal singleton pregnancies: modeling with quantile regression. Arch Gynecol Obstet 2013; 289:967-72. [DOI: 10.1007/s00404-013-3087-2] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2013] [Accepted: 10/30/2013] [Indexed: 11/25/2022]
|
13
|
Abstract
Introduction: Amniotic fluid, once thought to merely provide protection and room for necessary movement and growth for the fetus, is now understood to be a highly complex and dynamic system that is studied as a data point to interpret fetal wellbeing. Methods: Assessment of amniotic fluid volume is now routine when performing a sonographic evaluation of fetal status and is an important consideration in the assessment and management of perinatal morbidity and mortality.1,2 In this review, we will cover the dynamics that affect amniotic fluid volume, review methods for measurement and quantification of volume, review definitions for normative data as related to neonatal outcomes, and provide evidence based guidance on the workup and management options for oligoydramnios and polyhydramnios in singleton and twin pregnancies. Conclusions: When abnormalities of fluid exist, appropriate workup to uncover the underlying etiology should be initiated as adverse fetal outcomes are sometimes associated with these variations from normalcy.
Collapse
Affiliation(s)
| | - Everett F Magann
- University of Arkansas for Medical Sciences Little Rock Arkansas USA
| |
Collapse
|
14
|
Hogan J, Dourthe ME, Blondiaux E, Jouannic JM, Garel C, Ulinski T. Renal outcome in children with antenatal diagnosis of severe CAKUT. Pediatr Nephrol 2012; 27:497-502. [PMID: 22167562 DOI: 10.1007/s00467-011-2068-6] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/30/2011] [Revised: 11/13/2011] [Accepted: 11/15/2011] [Indexed: 11/26/2022]
Abstract
BACKGROUND Congenital abnormalities of the kidney and the urinary tract (CAKUT) are among the most frequent causes of antenatal consultation. In this retrospective study we evaluated the outcome of children for whom antenatal consultation was performed between 2006 and 2011 in one single pediatric nephrology center, with a particular focus on the outcome of children whose parents declined a therapeutic abortion. CASE-DIAGNOSIS/TREATMENT Thirty-four cases of isolated CAKUT were found. Of these, 19 terminations of pregnancies (TOP) were proposed, and ten TOP were refused for these patients. Among the ten infants whose parents refused an abortion, five died in the first month of life. Their median creatinine level at 3 days of life was 56 (range 25-316) μmol/L. For the five surviving patients, the median age at the time of analysis was 29 months, at which time all had a normal serum creatinine with a variable degree of proteinuria.Oligohydramnios was found in three of the patients who died. However, two of the five surviving patients also had oligohydramnios. CONCLUSION In ten patients for whom TOP was proposed for severe CAKUT and refused, five had normal serum creatinine at a median age of 29 months. No one predictive factor seems to have sufficient specificity to motivate a therapeutic abortion proposal, suggesting the need of long-term follow-up studies.
Collapse
Affiliation(s)
- Julien Hogan
- Department of Pediatric Nephrology, Armand Trousseau Hospital, l'Assistance Publique-Hôpitaux de Paris (APHP), 26, Avenue du Dr Arnold Netter, 75012, Paris, France
| | | | | | | | | | | |
Collapse
|
15
|
Abele H, Starz S, Hoopmann M, Yazdi B, Rall K, Kagan KO. Idiopathic Polyhydramnios and Postnatal Abnormalities. Fetal Diagn Ther 2012; 32:251-5. [PMID: 22760013 DOI: 10.1159/000338659] [Citation(s) in RCA: 41] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2012] [Accepted: 04/05/2012] [Indexed: 01/06/2023]
Affiliation(s)
- Harald Abele
- Department of Obstetrics and Gynaecology, University of Tübingen, Tübingen, Germany
| | | | | | | | | | | |
Collapse
|
16
|
Magann EF, Chauhan SP, Sanderson M, McKelvey S, Dahlke JD, Morrison JC. Amniotic fluid volume in normal pregnancy: Comparison of two different normative datasets. J Obstet Gynaecol Res 2011; 38:364-70. [DOI: 10.1111/j.1447-0756.2011.01710.x] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
|
17
|
Magann EF, Sandlin AT, Ounpraseuth ST. Amniotic fluid and the clinical relevance of the sonographically estimated amniotic fluid volume: oligohydramnios. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2011; 30:1573-1585. [PMID: 22039031 DOI: 10.7863/jum.2011.30.11.1573] [Citation(s) in RCA: 37] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
The amniotic fluid volume (AFV) is regulated by several systems, including the in-tramembranous pathway, fetal production (fetal urine and lung fluid) and uptake (fetal swallowing), and the balance of fluid movement via osmotic gradients. The normal AFV across gestation has not been clearly defined; consequently, abnormal volumes are also poorly defined. Actual AFVs can be measured by dye dilution techniques and directly measured at cesarean delivery; however, these techniques are time-consuming, are invasive, and require laboratory support, and direct measurement can only be done at cesarean delivery. As a result of these limitations, the AFV is estimated by the amniotic fluid index (AFI), the single deepest pocket, and subjective assessment of the AFV. Unfortunately, sonographic estimates of the AFV correlate poorly with dye-determined or directly measured amniotic fluid. The recent use of color Doppler sonography has not improved the diagnostic accuracy of sonographic estimates of the AFV but instead has led to overdiagnosis of oligohydramnios. The relationship between the fixed cutoffs of an AFI of 5 cm or less and a single deepest pocket of 2 cm or less for identifying adverse pregnancy outcomes is uncertain. The use of the single deepest pocket compared to the AFI to identify oligohydramnios in at-risk pregnancies seems to be a better choice because the use of the AFI leads to an increase in the diagnosis of oligohydramnios, resulting in more labor inductions and cesarean deliveries without any improvement in peripartum outcomes.
Collapse
Affiliation(s)
- Everett F Magann
- Department of Obstetrics and Gynecology, University of Arkansas for the Medical Sciences, Little Rock, AR 72205 USA.
| | | | | |
Collapse
|
18
|
|
19
|
Abstract
During human morphogenesis, intrauterine liquid movements, whose amniotic fluid is at the first place, play an essential part with some unexpected consequences on the vestibular apparatus development and function. Underlying the ubiquitous container-content relation, they give a new and effective approach of the morphogenetic process.
Collapse
|
20
|
Zanotti-Fregonara P, Jan S, Champion C, Trébossen R, Maroy R, Devaux JY, Hindié E. In vivo quantification of 18f-fdg uptake in human placenta during early pregnancy. HEALTH PHYSICS 2009; 97:82-85. [PMID: 19509511 DOI: 10.1097/01.hp.0000346703.78971.0d] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
18F-FDG is the most widely used PET radiopharmaceutical. Nevertheless, no data for 18F-FDG uptake in the human placenta have been reported. We recently reported on embryo dosimetry in a woman who underwent an 18F-FDG PET/CT scan during early pregnancy. In the present work we attempt an in vivo quantification of the 18F-FDG uptake by the placenta. The 27-y-old woman received 320 MBq of 18F-FDG for a follow-up study for Hodgkin's lymphoma and was later discovered to be pregnant (embryo age = 8 wk). Imaging started 1 h after injection. The maximum placental tissue uptake (SUVmax) was 2.5. This value was conservatively attributed to the entire placental volume, i.e., 45 mL, a value representative of the average dimensions of a normal placenta at 8 wk. On the basis of these measurements, placenta 18F-FDG uptake in our patient was 0.19% of the injected activity. A Monte Carlo simulation was used to derive the photon dose to the embryo from the placenta (0.022 x 10(-2) mGy per MBq of injected 18F-FDG) and from the surrounding amniotic fluid (0.017 x 10(-2) mGy MBq(-1)). This increases our previously calculated dose (3.3 x 10(-2) mGy MBq(-1)) by only a small fraction (1.18%), which does not justify modifying the previous estimate given the overall uncertainties.
Collapse
|
21
|
Human and murine amniotic fluid c-Kit+Lin- cells display hematopoietic activity. Blood 2009; 113:3953-60. [PMID: 19221036 DOI: 10.1182/blood-2008-10-182105] [Citation(s) in RCA: 97] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022] Open
Abstract
We have isolated c-Kit(+)Lin(-) cells from both human and murine amniotic fluid (AF) and investigated their hematopoietic potential. In vitro, the c-Kit(+)Lin(-) population in both species displayed a multilineage hematopoietic potential, as demonstrated by the generation of erythroid, myeloid, and lymphoid cells. In vivo, cells belonging to all 3 hematopoietic lineages were found after primary and secondary transplantation of murine c-Kit(+)Lin(-) cells into immunocompromised hosts, thus demonstrating the ability of these cells to self-renew. Gene expression analysis of c-Kit(+) cells isolated from murine AF confirmed these results. The presence of cells with similar characteristics in the surrounding amnion indicates the possible origin of AF c-Kit(+)Lin(-) cells. This is the first report showing that cells isolated from the AF do have hematopoietic potential; our results support the idea that AF may be a new source of stem cells for therapeutic applications.
Collapse
|
22
|
Abstract
From the moment of implantation until delivery some 37 weeks later, the human embryo or fetus is surrounded by fluid. Initially this fluid is a transudate from maternal and embryonic tissues which provides nutrients for the growing embryo. Starting in early pregnancy, the fetal kidneys begin to contribute substantial quantities of urine to the amniotic fluid volume. At mid pregnancy, when the skin becomes keratinized, the kidneys become the main source of amniotic fluid. Fetal swallowing is the main route of amniotic fluid removal. Although fetal urine production and swallowing have been studied in both human pregnancy and animal models, the knowledge from these investigations is not sufficiently extensive to explain overall amniotic fluid volume regulation. None the less, it is clear that the amniotic fluid is in a dynamic, ever-changing state. The production rate of the fetal urine in the human fetus at term (800–1200ml/day) is sufficient to replace completely the entire amniotic volume every 12–24 hours1. While the fetus is producing large volumes of urine, the volume of amniotic fluid is normally maintained within a very narrow range. Deviations from the normal range are often associated with significant perinatal morbidity and mortality.
Collapse
|
23
|
Hubert KC, Palmer JS. Current diagnosis and management of fetal genitourinary abnormalities. Urol Clin North Am 2007; 34:89-101. [PMID: 17145364 DOI: 10.1016/j.ucl.2006.10.002] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
Prenatal assessment with ultrasonography provides excellent imaging of fluid-filled structures (eg, hydronephrosis, renal cysts, and dilated bladder) and renal parenchyma. This information allows for the generation of a differential diagnosis, identification of associated anomalies, and assessment of the prenatal and postnatal risks of a given anomaly. This enhances parental education and prenatal and postnatal planning. This article discusses the current methods of diagnosis and management of fetal genitourinary anomalies, and also the postnatal evaluation and treatment of these conditions.
Collapse
Affiliation(s)
- Katherine C Hubert
- Case Western Reserve University, 11100 Euclid Avenue, Cleveland, OH 44106, USA
| | | |
Collapse
|
24
|
Fok WY, Chan LY, Lau TK. The influence of fetal position on amniotic fluid index and single deepest pocket. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2006; 28:162-5. [PMID: 16708416 DOI: 10.1002/uog.2802] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/09/2023]
Abstract
OBJECTIVE To evaluate the effect of fetal position on measurement of amniotic fluid index (AFI) and of the single deepest pocket (SDP). METHODS This was a prospective observational study, in a university obstetric unit, of women with an uncomplicated singleton pregnancy with longitudinal lie and cephalic presentation at or beyond 28 weeks of gestation. AFI was calculated and SDP measured and the fetal position was characterized in terms of three parameters. These were: the side of the maternal abdomen on which the fetus lay; a numerical representation (laterality score) of the distance that the fetus was from the sagittal midline plane of the maternal abdomen; the orientation of the fetal trunk (ventral anterior, lateral or posterior). RESULTS Eighty-one women were recruited into the study. There was a significant relationship between the laterality score and the AFI (P = 0.005) but not the SDP (P = 0.23): AFI was on average 4.35 cm higher in fetuses lying centrally compared with those lying laterally inside the uterus. There was no significant difference for either SDP (P = 0.8) or AFI (P = 0.3) between fetuses lying on the right or the left side of the maternal abdomen. Similarly, there was no significant difference in SDP (P = 0.9) or AFI (P = 1.0) for the different orientations of the fetal trunk. CONCLUSION Fetal position affects the measurement of AFI but not that of SDP. Therefore, SDP may be a more consistent parameter for the estimation of amniotic fluid volume.
Collapse
Affiliation(s)
- W Y Fok
- Department of Obstetrics and Gynaecology, Prince of Wales Hospital, The Chinese University of Hong Kong, Hong Kong.
| | | | | |
Collapse
|
25
|
Cheung CY, Brace RA. Amniotic fluid volume and composition in mouse pregnancy. ACTA ACUST UNITED AC 2006; 12:558-62. [PMID: 16325744 DOI: 10.1016/j.jsgi.2005.08.008] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 08/05/2005] [Indexed: 11/20/2022]
Abstract
OBJECTIVE The current study was undertaken to determine simultaneous changes in amniotic fluid (AF) volume and composition across gestation in the pregnant mouse. METHODS Young adult mice (6 to 7 weeks old) of the CB6F1 strain were mated overnight. AF was collected on consecutive days from embryonic days 9.5 through 18.5 for measurements of volume and composition. Statistical analysis included one-factor analysis of variance (ANOVA). RESULTS AF volume increased from 18 +/- 4 (SE) microL on day 9.5 to a maximum of 147 +/- 4 microL on days 15.5 to 16.5 and decreased sharply to 17 +/- 3 microL on day 18.5. AF osmolality was unchanged except for a rise prior to delivery on day 19.5 to 20.5. AF sodium, calcium, and glucose concentrations increased and subsequently decreased as gestation progressed. AF potassium, chloride, and lactate concentrations initially decreased and then increased across gestation. Prior to day 9.5 and after day 18.5, AF volume was too small for volume or compositional determinations. CONCLUSIONS In the mouse, the rise in AF volume from mid gestation to a maximum late in gestation is similar to that in humans while the sharp fall prior to delivery is not. As observed in the fetal sheep, the changes in fluid volume are associated with AF osmolality and solute concentration changes that are correlated with advancing gestational age. These observations together with the feasibility of quantifying AF volume and composition in the mouse fetus demonstrate the possibility of using genetically altered mice as a model for future studies on the molecular mechanisms underlying the regulation of AF volume and composition.
Collapse
Affiliation(s)
- Cecilia Y Cheung
- Division of Perinatal Medicine, Department of Reproductive Medicine, University of California San Diego, La Jolla, California 92093-0802, USA.
| | | |
Collapse
|
26
|
Costa FDS, Cunha SPD, Berezowski AT. Avaliação prospectiva do índice de líquido amniótico em gestações normais e complicadas. Radiol Bras 2005. [DOI: 10.1590/s0100-39842005000500006] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
OBJETIVO: Analisar, prospectivamente, o índice de líquido amniótico em gestantes de baixo risco que apresentaram ou não complicações da gestação e do período perinatal. MATERIAIS E MÉTODOS: Foi estudado, de modo prospectivo, o índice de líquido amniótico de 45 primigestas sem doenças no momento da inclusão no estudo. O índice foi avaliado em quatro períodos da gestação - 18-20, 24-26, 28-30 e 34-36 semanas - e seus valores foram correlacionados com o surgimento de complicações gestacionais e perinatais, Doppler das artérias uterinas, idade gestacional ao parto, vias de parto e o peso dos recém-nascidos. RESULTADOS: O índice de líquido amniótico não mostrou diferença estatística entre as pacientes com gestações normais e complicadas em nenhum dos quatro períodos estudados. Também não mostrou associação com a idade gestacional ao parto, as vias de parto e o peso dos recém-nascidos. Observou-se que a média do índice de líquido amniótico entre 28-30 semanas é mais elevada (p = 0,004) nas pacientes com incisura bilateral do que nas com Doppler normal. CONCLUSÃO: A avaliação prospectiva do índice de líquido amniótico em gestações de baixo risco parece não ser um bom preditor de complicações gestacionais ou perinatais.
Collapse
|
27
|
Khadilkar SS, Desai SS, Tayade SM, Purandare CN. Amniotic fluid index in normal pregnancy: an assessment of gestation specific reference values among Indian women. J Obstet Gynaecol Res 2003; 29:136-41. [PMID: 12841695 DOI: 10.1046/j.1341-8076.2003.00089.x] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
AIM To obtain a gestational reference range for the amniotic fluid index (AFI) among Indian women. METHODS An analysis of AFI estimations was undertaken in 517 Indian women with normal pregnancy between 16 and 42 weeks of gestation. It was a prospective, cross-sectional study conducted in a university teaching hospital. Women with fetal anomalies, pregnancy-induced hypertension, diabetes mellitus, and other maternal complications were excluded from the study. The median, the 5th and the 95th percentile values were calculated for each gestational week and these values were compared with other studies. RESULTS The median reached its peak at the 27th week of gestation. We observed approximately 6 cm as the lower limit of normal (5th percentile) and approximately 18 cm (95th percentile) as upper limit of normal AFI at term for our population, whereas in the Caucasian population, the values were approximately 7 cm and approximately 20 cm, respectively. All gestation specific AFI values were lower in the studied population of Indian women compared with other studies on Caucasian population (P < 0.01 for 5th percentile & P < 3.26 x 10(-7) for 95th percentile), but slightly higher than the Chinese population. CONCLUSION Amniotic fluid index values differ in different populations. We standardized the reference values for normal AFI in Indian women. We found that they are lower in the population studied compared with reported values in the Caucasian population, but slightly higher than the Chinese population.
Collapse
Affiliation(s)
- Suvarna S Khadilkar
- Department of Obstetrics and Gynecology, Grant Medical College, Mumbai, Maharashtra, India.
| | | | | | | |
Collapse
|
28
|
Goldkrand JW, Hough TM, Lentz SU, Clements SP, Bryant JL, Hodges JA. Comparison of the amniotic fluid index with gray-scale and color Doppler ultrasound. J Matern Fetal Neonatal Med 2003; 13:318-22. [PMID: 12916682 DOI: 10.1080/jmf.13.5.318.322] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
OBJECTIVES This study was undertaken to compare the amniotic fluid index (AFI) obtained with gray-scale ultrasound and color Doppler. STUDY DESIGN We examined 77 patients ranging from 22 to 41 weeks' gestation with two of five sonographers obtaining two measures of the AFI utilizing gray-scale and color Doppler. RESULTS Of the measurements of AFI, 96% showed the gray scale measurement to be greater than the color measurement (p < 0.0001; mean 9.3 +/- 3.3 cm vs. 8.5 +/- 3.0 cm). At gray-scale AFI < 5 cm, color AFI was essentially the same, but at gray-scale AFI 5-10 cm, color AFI was < 5 cm, 15.2% and 7.8% of the time. At gray-scale AFI > 10 cm, no color AFI was < 5 cm. Individual (n = 5) interobserver reliability was r = 0.79 (p < 0.0001) and intraobserver reliability was r = 0.94 (p < 0.0001). CONCLUSIONS AFI by color Doppler was always less than with gray scale. At an AFI of 5-10 cm, color demonstrated an AFI of < 5 cm in up to 16% of patients, and increased the diagnosis of oligohydramnios.
Collapse
Affiliation(s)
- J W Goldkrand
- Memorial Health University Medical Center, Savannah, Georgia, USA
| | | | | | | | | | | |
Collapse
|
29
|
Magann EF, Whitworth NS, Files JC, Terrone DA, Chauhan SP, Morrison JC. Dye-dilution techniques using aminohippurate sodium: do they accurately reflect amniotic fluid volume? J Matern Fetal Neonatal Med 2002; 11:167-70. [PMID: 12380671 DOI: 10.1080/jmf.11.3.167.170] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
OBJECTIVE To determine whether the dye-dilution technique using aminohippurate sodium accurately measures amniotic fluid volume. METHODS Singleton pregnancies with intact membranes undergoing a Cesarean delivery had their amniotic fluid volume assessed by the dye-dilution technique and direct measurement. RESULTS Fifteen women were prospectively assessed. Six patients had their amniocentesis on the delivery table and nine patients at 4-24 h prior to the Cesarean delivery. The six women undergoing an amniocentesis just before delivery had good concordance between the dye-determined and direct measurement of amniotic fluid volume (r = 0.99, p = < 0.001). Among the nine women with varying times from amniocentesis to direct measurement, the correlation was not significant (r = 0.36, p = 0.08). The percentage difference between the dye-determined and directly measured amniotic fluid volume was significantly smaller in the women undergoing amniocentesis just prior to delivery (7%) than in the women with varying times from amniocentesis to delivery (37%, P < 0.001). CONCLUSION Dye-determined amniotic fluid volume accurately reflects actual amniotic fluid volume but the dye-determined concentrations, in vivo, may undergo rapid changes.
Collapse
Affiliation(s)
- E F Magann
- Department of Obstetrics and Gynecology, University of Mississippi Medical Center, Jackson, USA
| | | | | | | | | | | |
Collapse
|
30
|
|
31
|
Deyer TW, Ashton-Miller JA, Van Baren PM, Pearlman MD. Myometrial contractile strain at uteroplacental separation during parturition. Am J Obstet Gynecol 2000; 183:156-9. [PMID: 10920324 DOI: 10.1067/mob.2000.105819] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
OBJECTIVE A simplified geometric model of the uterine wall during the second and third stages of labor was created to estimate the magnitude of myometrial strain associated with the initiation of placental separation. STUDY DESIGN The uterine wall was modeled as an isovolumetric, incompressible spherical shell whose overall radius decreased and mural thickness increased on uterine muscle contraction after delivery of the fetus. Either a 3.5-MHz or a 5-MHz ultrasonography probe was used to measure the change in uterine mural thickness of 14 healthy patients from just before delivery to the time of initial separation of the placenta. The measured change in uterine wall thickness was then used to calculate its average radial and circumferential strain with a simple mathematic model. RESULTS Placental separation occurred at radial and circumferential strains (mean +/- SD) of 450% +/- 182% and -75% +/- 11%, respectively. These strains are consistent with the known maximal contractile strains achievable by smooth muscle. CONCLUSION Placental separation is likely associated with maximal myometrial contractile strain. Before birth the presence of the fetal and amniotic fluid volumes usually renders such contractile strains unachievable, thereby helping to guard against premature placental separation.
Collapse
Affiliation(s)
- T W Deyer
- Department of Biomedical Engineering, College of Engineering, University of Michigan, Ann Arbor, USA
| | | | | | | |
Collapse
|
32
|
Magann EF, Martin JN. Amniotic fluid volume assessment in singleton and twin pregnancies. Obstet Gynecol Clin North Am 1999; 26:579-93. [PMID: 10587956 DOI: 10.1016/s0889-8545(05)70100-5] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
The best method of ultrasonic mensuration to identify abnormal AFV reliably in singletons and the individual sacs of diamniotic twins remains elusive. With respect to twins, localization of the dividing membrane seems to be necessary for AFV assessments of each amniotic cavity. The relationship of ultrasonic estimates, actual AFV, and pregnancy outcome remains undetermined. In the authors' opinion, the subjective assessment in twin gestation may be as accurate as semiquantitative ultrasonic estimates of AFV, similar to the situation in singleton pregnancies. The authors propose that further prospective research address the following questions: (1) What is the appropriate threshold for intervention when AFI decreases to lower ranges? (2) What other factors (e.g., cervical examination, fetal heart rate patterns, underlying obstetric conditions, fetal growth pattern) are important when the AFI falls to low values in making clinical decisions?
Collapse
Affiliation(s)
- E F Magann
- Department of Obstetrics and Gynecology, University of Mississippi Medical Center, Jackson, USA
| | | |
Collapse
|
33
|
Dubiel M, Kozber H, Debniak B, Breborowicz GH, Marsal K, Gudmundsson S. Fetal and placental power Doppler imaging in normal and high-risk pregnancy. EUROPEAN JOURNAL OF ULTRASOUND : OFFICIAL JOURNAL OF THE EUROPEAN FEDERATION OF SOCIETIES FOR ULTRASOUND IN MEDICINE AND BIOLOGY 1999; 9:223-30. [PMID: 10657597 DOI: 10.1016/s0929-8266(99)00027-0] [Citation(s) in RCA: 18] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
Abstract
OBJECTIVE Computer analysis of organ power Doppler (PD) imaging has recently become available. The aim of the study was to evaluate gestational trends in placenta-, fetal lung-, liver- and kidney-blood flow in normal pregnancies and relate it to signals in high-risk pregnancies. METHODS PD signals were recorded in normal singleton pregnancies between 26 and 42 weeks of gestation. Signals were also recorded in 63 high-risk pregnancies. Fixed preinstalled PD system installations for each organ were used during examinations. Images from PD scan were recorded on video tape and off-line analysed by computer. Mean flow signal intensity was calculated for each organ. Umbilical and uterine artery Doppler velocimetry were also recorded in high-risk pregnancies. RESULTS PD signals from the four organs indicated increasing organ blood flow until approximately 34 weeks of gestation, from where the organ signals seemed to decrease. High-risk pregnancies seemed to have lower PD signal intensity, which was more pronounced in cases with signs of placental vascular resistance. CONCLUSION The results suggest that a decrease in fetal organ blood flow might indicate a centralisation of fetal circulation in normal pregnancy at term, as a physiological response to a decrease in placental perfusion. In the high-risk pregnancies the placental and fetal organ blood flow seem to be even further reduced, suggesting a more intense centralisation of circulation.
Collapse
Affiliation(s)
- M Dubiel
- University School of Medical Sciences, Department of Perinatology, University Hospital Poznań, Poznań, Poland
| | | | | | | | | | | |
Collapse
|
34
|
Konrad M, Leonhardt A, Hensen P, Seyberth HW, Köckerling A. Prenatal and postnatal management of hyperprostaglandin E syndrome after genetic diagnosis from amniocytes. Pediatrics 1999; 103:678-83. [PMID: 10049979 DOI: 10.1542/peds.103.3.678] [Citation(s) in RCA: 42] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
OBJECTIVE To describe prenatal genetic diagnosis in hyperprostaglandin E syndrome (HPS) and the effect of indomethacin therapy on the course of the disease before birth and in the neonatal period. METHODS Mutational analysis of the ROMK channel gene (KCNJ1) from amniocytes by single-strand conformational analysis and direct sequencing. Review of the clinical and laboratory findings during pregnancy and the neonatal period in two siblings affected with HPS. RESULTS Compound heterozygosity of the fetus in KCNJ1 (D74Y/P110L) confirmed the clinical diagnosis of HPS at 26 weeks of gestation. Indomethacin therapy from 26 to 31 weeks prevented further progression of polyhydramnios without major side effects. In contrast to the elder brother, who had been diagnosed at the age of 2 months, the neonatal course was uncomplicated. Hypovolemic renal failure after excessive renal loss of salt and water could be prevented and severe nephrocalcinosis did not occur. CONCLUSIONS Genetic diagnosis of HPS and subsequent prenatal indomethacin therapy seems to have a beneficial effect on the natural course of HPS, especially progression of polyhydramnios; therefore, extreme prematurity could be prevented. Also, postnatally the early diagnosis allows the effective water and electrolyte substitution before severe volume depletion.
Collapse
Affiliation(s)
- M Konrad
- Department of Pediatrics, Philipps University, Marburg, Germany
| | | | | | | | | |
Collapse
|
35
|
Abstract
Abnormal amniotic fluid volume is associated with increased maternal risk and perinatal morbidity and mortality. Until the advent of ultrasonography, the invasive nature of amniotic fluid volume assessment limited its clinical utility. Refinements in quantifying the noninvasive sonographic assessment of oligohydramnios and hydramnios have improved the ability of clinicians to identify at-risk pregnancies. This article reviews the available methods of amniotic fluid volume assessment and outlines a comprehensive approach to sonographic screening and monitoring.
Collapse
Affiliation(s)
- J E Larmon
- Department of Obstetrics and Gynecology, University of Mississippi Medical Center, Jackson, USA
| | | |
Collapse
|
36
|
Abstract
Amniotic fluid volume should be routinely assessed in every second and third trimester case. A review of amniotic fluid physiology and techniques for ultrasound evaluation of fluid volume is presented. The causes and significance of oligohydramnios and polyhydramnios are stressed. Umbilical cord abnormalities are often incidently observed at the time of amniotic fluid evaluation. The clinical significance of some common umbilical cord abnormalities such as a two-vessel cord and nuchal cord are discussed. Other, more uncommon entities such as cord mass lesions are also reviewed. Finally, the role of cord Doppler interrogation in determining fetal well-being is discussed.
Collapse
Affiliation(s)
- R Sohaey
- Women's Imaging, Grandvalley Radiology, Holland, MI, USA
| |
Collapse
|
37
|
Affiliation(s)
- L M Hill
- Magee-Womens Hospital, Department of Obstetrics, Gynecology and Reproductive Sciences, Pennsylvania 15213, USA
| |
Collapse
|
38
|
Chau AC, Kjos SL, Kovacs BW. Ultrasonographic measurement of amniotic fluid volume in normal diamniotic twin pregnancies. Am J Obstet Gynecol 1996; 174:1003-7. [PMID: 8633626 DOI: 10.1016/s0002-9378(96)70340-x] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
OBJECTIVE Our purpose was to determine the amniotic fluid volume in normal diamniotic twins. STUDY DESIGN The single amniotic fluid index for both twin members, the maximum depth and width of each twin's largest pocket, were measured every 4 to 6 weeks between 15 and 40 weeks in 91 normal diamniotic twin gestations. The two-diameter pocket in each twin was determined as its largest pocket's depth multiplied by its width. Normal twin gestations were defined as those with <20% birth weight discordance, appropriate for gestational age, no fetal anomalies, delivery at > or = 37 weeks, and normal newborns. Amniotic fluid index values, depths, and two-diameter pockets were stratified into 2-week intervals and transformed into base 10 logarithms because of their nongaussian distributions. The correlations of these measurement with gestational age were evaluated. Their means and 90%, 95%, and 98% confidence intervals were determined. RESULTS The amniotic fluid index changed significantly with gestational age. However, depths and two-diameter pockets did not. The amniotic fluid index rose from 15 to 24 weeks, plateaued until 36 weeks, and then declined. The 90%, 95%, and 98% confidence intervals for each twin's depth were 2.4 to 7.9, 2.1 to 8.8, and 1.9 to 10 cm, respectively (mean 4.3 cm). These respective confidence intervals for each twin's two-diameter pocket were 8 to 44, 7 to 52, and 5 to 63 cm2 (mean 19 cm2). The amniotic fluid index confidence interval curves were plotted from the log (amniotic fluid index)=0.8276 + 0.01675x-0.0000001900x4, R2=0.78, p=0.002 (where x is gestational age). CONCLUSION The amniotic fluid volume in normal diamniotic twin pregnancies was established ultrasonographically. Only the amniotic fluid index changed significantly with gestational age. These findings may have significance in the clinical management of twin gestation.
Collapse
Affiliation(s)
- A C Chau
- Division of Maternal-Fetal Medicine, Department of Obstetrics and Gynecology, University of Southern California, Los Angeles, USA
| | | | | |
Collapse
|
39
|
Van Allen MI, Brown ZA, Plovie B, Hanson ML, Knopp RH. Deformations in infants of diabetic and control pregnancies. AMERICAN JOURNAL OF MEDICAL GENETICS 1994; 53:210-5. [PMID: 7856654 DOI: 10.1002/ajmg.1320530303] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Abstract
Severe and mild deformations in newborn infants of insulin dependent diabetic mothers (IDDMs) and control mothers were evaluated with respect to the types of anomalies and previously hypothesized constraint factors. Factors evaluated were gestational length, birth weight, corrected birth weight for gestation (weight ratio), maternal height and parity, and severe deformations. Newborn infants from 81 control and 133 insulin dependent diabetic pregnancies were recruited periconceptually as part of a larger study of diabetes in early pregnancy. Examinations were done at 48 to 72 hours of life by one examiner blinded to maternal status using a checklist of major and minor deformations and malformations. Mild deformations were found to be common and were present in 84% of newborn infants. Severe deformations occurred in three (1.4%) IDMs, with two of three newborn infants having major malformations involving the CNS and/or musculoskeletal system which affected fetal movement. There was no significant difference between IDMs and control newborn infants with respect to the number with deformations; however, fetal macrosomia was not present in study participants. Using the entire cohort, a significantly greater number of deformations were present in newborn infants with a gestation > 36 weeks (P < 0.001), birth weight > 3,000 g (P < 0.001), and weight ratio > or = 1.2 (P = 0.05). There was no significant association with primiparous mothers or women with a height < 165 cm and the presence of deformations. For gestational age and birth weight, mild deformations were apparent only after 33 weeks gestation (P << 0.001) and/or birth weights of 2.0 kg or more (P << 0.001).(ABSTRACT TRUNCATED AT 250 WORDS)
Collapse
Affiliation(s)
- M I Van Allen
- Department of Medical Genetics, University of British Columbia, Vancouver, Canada
| | | | | | | | | |
Collapse
|
40
|
Nagata S, Koyanagi T, Fukushima S, Akazawa K, Nakano H. Change in the three-dimensional shape of the stomach in the developing human fetus. Early Hum Dev 1994; 37:27-38. [PMID: 8033785 DOI: 10.1016/0378-3782(94)90144-9] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
To reveal the developmental characteristics of the fetal stomach in utero, this study was made on 879 subjects from 20 to 40 weeks' gestation. By applying the system of 'Modeling a three-dimensional shape from a silhouette by detecting symmetry' which we devised, we reconstructed the three-dimensional shape, from the outline of the longitudinally transected fetal stomach, obtained from the real-time ultrasound image. Age-related changes in gastric volume and sphericality (parameters produced by the above mentioned method) were analyzed using piecewise linear regression. The fetal stomach volume increased linearly from 20 to 37 weeks' gestation and decreased thereafter to 40 weeks' gestation, with a critical point at 37 weeks' gestation. The sphericality of the fetal stomach shape was also seen to decrease linearly from 20 weeks' to the critical point at 27 weeks' gestation, thereafter remaining constant regardless of the advance in gestation to term. These findings indicate that at 20-27 weeks' gestation, the stomach is of a fusiform-like shape. From 27 weeks' gestation onwards, greater and lesser curvatures become apparent, clearly identifying the cardiac and pyloric regions. The decrease in stomach size after 37 weeks' gestation is also in good accord with the decrease in amniotic fluid volume. The analytical method presented here can help to understand the pathogenesis of gastrointestinal lesions in the developing fetus.
Collapse
Affiliation(s)
- S Nagata
- Department of Gynecology and Obstetrics, Faculty of Medicine, Kyushu University, Fukuoka, Japan
| | | | | | | | | |
Collapse
|
41
|
Nwosu EC, Welch CR, Manasse PR, Walkinshaw SA. Longitudinal assessment of amniotic fluid index. BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY 1993; 100:816-9. [PMID: 8218000 DOI: 10.1111/j.1471-0528.1993.tb14305.x] [Citation(s) in RCA: 37] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Abstract
OBJECTIVE To derive a longitudinal gestational reference range for amniotic fluid index and to compare it with the established cross-sectional reference range. DESIGN Longitudinal prospective study. SETTING Liverpool Maternity Hospital and Mill Road Maternity Hospital, both teaching hospitals in central Liverpool. SUBJECTS One hundred and fifteen pregnant women, in whom the expected date by the last menstrual period and ultrasound scan at 18 to 19 weeks were in agreement by seven days, were recruited. They were divided into two groups and scanned at four weekly intervals as follows: Group A: scanned at 20, 24, 28, 32, 36, 40; and Group B: scanned at 22, 26, 30, 34, 38, 42. RESULTS Amniotic fluid index varies with gestation, rising from early gestation to peak at 30 weeks and then falling from 36 to 42 weeks. Comparison of our reference range with that of Moore and Cayle (1990) shows obvious differences at the lower limit. CONCLUSION We have established a normal longitudinal reference range for the amniotic fluid index. Our ranges, derived from longitudinal data, would seem a more appropriate reference than the established reference ranges derived from cross-sectional data. In particular, the differences at the lower limits may have considerable clinical implication in the use of amniotic fluid index in the prediction of fetal compromise.
Collapse
|
42
|
Hashimoto BE, Kramer DJ, Brennan L. Amniotic fluid volume: fluid dynamics and measurement technique. Semin Ultrasound CT MR 1993; 14:40-55. [PMID: 8481266 DOI: 10.1016/s0887-2171(05)80068-x] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
Evaluation of amniotic fluid volume is an important aspect of obstetrical ultrasound. Several methods are currently used to describe amniotic fluid volumes. The most common are the subjective assessment of fluid and the semiquantitative methods. The reproducibility of these methods is excellent in experienced hands. Because of the multiple methods used to assess fluid, both oligohydramnios and polyhydramnios have numerous definitions. Regardless of which definition is used, it is clear that both of these entities are associated with a variety of fetal and maternal conditions. Abnormal amniotic fluid volume may be the only or earliest sonographic sign of an obstetrical problem. Therefore, it is important that sonologists are familiar with amniotic fluid volume assessment. Although subjective and semiquantitative techniques may produce similar results, a numerical scale is no substitute for experience and training. One should be able to recognize lesser degrees of fluid abnormality and be able to assess the trend of amniotic fluid volume in serial examinations.
Collapse
Affiliation(s)
- B E Hashimoto
- Department of Radiology, Virginia Mason Clinic, Seattle, WA 98111
| | | | | |
Collapse
|
43
|
Magann EF, Nolan TE, Hess LW, Martin RW, Whitworth NS, Morrison JC. Measurement of amniotic fluid volume: accuracy of ultrasonography techniques. Am J Obstet Gynecol 1992; 167:1533-7. [PMID: 1471660 DOI: 10.1016/0002-9378(92)91734-r] [Citation(s) in RCA: 92] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
OBJECTIVE Our purpose was to determine amniotic fluid volume by the dye-dilution technique and compare it with the amniotic fluid index, largest vertical pocket, and two-diameter pocket (defined as vertical x horizontal of the largest vertical pocket). STUDY DESIGN This prospective study involved 40 women undergoing amniocentesis in late pregnancy to detect fetal lung maturity or evidence of chorioamnionitis. The amniotic fluid volume was quantified ultrasonographically by means of the amniotic fluid index, largest vertical pocket, and two-diameter pocket. During amniocentesis the fluid volume was calculated by the dye-dilution technique of Charles and Jacoby. RESULTS Ultrasonographic measurements by amniotic fluid index, largest vertical pocket, and two-diameter pocket correctly predicted normal amniotic fluid and hydramnios (74%). A new measurement, two-diameter pocket, gave a significantly more accurate estimate of oligohydramnios than did amniotic fluid index (p < 0.002) or largest vertical pocket (p < 0.0003). CONCLUSION All three indices are moderately accurate in identifying normal amniotic fluid volume and hydramnios. Two-diameter pocket is the most accurate test to predict oligohydramnios.
Collapse
Affiliation(s)
- E F Magann
- Department of Obstetrics and Gynecology, University of Mississippi Medical Center, Jackson 39216-4505
| | | | | | | | | | | |
Collapse
|
44
|
Dildy GA, Lira N, Moise KJ, Riddle GD, Deter RL. Amniotic fluid volume assessment: comparison of ultrasonographic estimates versus direct measurements with a dye-dilution technique in human pregnancy. Am J Obstet Gynecol 1992; 167:986-94. [PMID: 1415438 DOI: 10.1016/s0002-9378(12)80025-1] [Citation(s) in RCA: 73] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
OBJECTIVE The purpose of our study was to compare the accuracy of clinical ultrasonographic techniques of amniotic fluid volume assessment with a dye-dilution technique. STUDY DESIGN We compared amniotic fluid volume as measured by ultrasonographic techniques with a dye-dilution method in 50 women undergoing amniocentesis during the third trimester. Thirteen separate ultrasonographic techniques, including the amniotic fluid index, were evaluated with regression analysis. RESULTS Amniotic fluid volumes as determined by dye-dilution ranged between 129 and 4444 ml. The amniotic fluid index overestimated the actual volume by as much as 88.7% at lower volumes and underestimated the actual volume by as much as 53.9% at higher volumes. CONCLUSIONS Differences in measurement error between the other ultrasonographic methods and the amniotic fluid index did not appear to be sufficient to warrant changes in current clinical practice. A major source of error in ultrasonographic amniotic fluid volume assessment is that one-dimensional measurements are used to estimate the volume of a complex, three-dimensional object.
Collapse
Affiliation(s)
- G A Dildy
- Department of Obstetrics and Gynecology, Baylor College of Medicine, Houston, Texas
| | | | | | | | | |
Collapse
|
45
|
Croom CS, Banias BB, Ramos-Santos E, Devoe LD, Bezhadian A, Hiett AK. Do semiquantitative amniotic fluid indexes reflect actual volume? Am J Obstet Gynecol 1992; 167:995-9. [PMID: 1415439 DOI: 10.1016/s0002-9378(12)80026-3] [Citation(s) in RCA: 41] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
OBJECTIVE Our objective was to determine how well semiquantitative ultrasonographic measures of amniotic fluid, i.e., maximal amniotic fluid vertical pocket and amniotic fluid index, reflect actual amniotic fluid volumes in 50 near-term patients whose amniotic fluid volume estimates were normal by visual inspection. STUDY DESIGN Before amniocentesis for fetal lung maturity, each patient had visual amniotic fluid volume estimates, maximal amniotic fluid vertical pocket, and amniotic fluid index performed by the same examiner, and then each received intraamniotic injection of a 10% paraaminohippurate solution. Amniotic fluid volume was quantitated by spectrophotometric assay of paraaminohippurate concentration. Oligohydramnios and polyhydramnios were defined as < 300 and > 2000 ml, respectively. RESULTS Quantitative amniotic fluid volume was positively related to both amniotic fluid index and maximal amniotic fluid vertical pocket (r = 0.75 and 0.60, respectively). True-positive rates for oligohydramnios (amniotic fluid index < 5 cm or maximal amniotic fluid vertical pocket < 2 cm) were 100% and 0%, respectively; false-positive rates with either method were 0%. True-positive rates for polyhydramnios (amniotic fluid index > 20 cm and maximal amniotic fluid vertical pocket > 8 cm) were 0%; false-positive rates were 16% and 24%, respectively. CONCLUSIONS Amniotic fluid index appears to be slightly better than maximal amniotic fluid vertical pocket for reflecting actual amniotic fluid volume. Both indirect methods tend to overestimate actual amniotic fluid volume at the upper end of its extremes.
Collapse
Affiliation(s)
- C S Croom
- Department of Obstetrics and Gynecology, Medical College of Georgia, Augusta 30912
| | | | | | | | | | | |
Collapse
|
46
|
Austgulen R, Liabakk NB, Brockhaus M, Espevik T. Soluble TNF receptors in amniotic fluid and in urine from pregnant women. J Reprod Immunol 1992; 22:105-16. [PMID: 1323674 DOI: 10.1016/0165-0378(92)90009-s] [Citation(s) in RCA: 40] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
Secretion of soluble cytokine receptors has been suggested as a mechanism for regulation of cytokine activity in vivo. The present investigation was performed to study whether secretion of soluble TNF (tumor necrosis factor) receptors (TNFRs) might be associated with pregnancy. There are two known molecular species of the TNFR, the 55-kDa TNFR and the 75-kDa TNFR. The 75-kDa, as well as the 55-kDa TNFR, was detected in urine from pregnant women, whereas only the 75-kDa TNFR was detected in urine from the non-pregnant group. The concentration of TNFRs in urine increased towards term and was reduced in association with spontaneous delivery. The soluble forms of both TNFRs were also detected in amniotic fluid. Collectively, the data suggest that secretion of soluble TNFRs during pregnancy might be a defence mechanism for the protection of the fetus against TNF action.
Collapse
Affiliation(s)
- R Austgulen
- Department of Pediatrics, University Hospital of Trondheim, Norway
| | | | | | | |
Collapse
|
47
|
Hendricks SK, Conway L, Wang K, Komarniski C, Mack LA, Cyr D, Uhrich S. Diagnosis of polyhydramnios in early gestation: indication for prenatal diagnosis? Prenat Diagn 1991; 11:649-54. [PMID: 1837357 DOI: 10.1002/pd.1970110824] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
Previously published reports have indicated that idiopathic polyhydramnios may be associated with trisomies 18 and 21 and that chromosomal analysis is indicated. Furthermore, the natural history and fetal outcome of polyhydramnios diagnosed in early gestation have not been well delineated. We identified 138 pregnancies with polyhydramnios prior to 26 weeks' gestation. Of 131 complete cases, 21 were diagnosed as severe, 18 as moderate, and 92 as mild polyhydramnios. Congenital abnormalities were noted in 18 of 21 severe cases (86 per cent). Two of the remaining three cases were twin-to-twin transfusion. Thirteen of 18 cases with moderate polyhydramnios (72 per cent) were associated with anomalies; six of the remaining cases were twin-to-twin transfusion. Sixteen of 92 cases of mild polyhydramnios (17 per cent) were associated with congenital abnormalities. In 69 of 76 cases of mild hydramnios not associated with anomalies (91 per cent), the hydramnios resolved prior to delivery. Only 2 of 16 (13 per cent) associated with anomalies resolved. In 4 of 5 cases (80 per cent) with moderate hydramnios and no anomalies, the amniotic fluid volume was normal on subsequent ultrasound. No case of moderate polyhydramnios associated with anomalies or maternal conditions nor any case of severe polyhydramnios resolved. There were seven cases of chromosomal abnormalities in this series; all were associated with sonographic findings in addition to the presence of polyhydramnios. On the basis of these data, we doubt the benefit of amniocentesis following the early diagnosis of idiopathic polyhydramnios in the absence of other ultrasound findings.
Collapse
MESH Headings
- Chromosomes, Human, Pair 17
- Chromosomes, Human, Pair 19
- Chromosomes, Human, Pair 4
- Chromosomes, Human, Pair 9
- Congenital Abnormalities/diagnosis
- Down Syndrome
- Female
- Fetofetal Transfusion/complications
- Humans
- Polyhydramnios/complications
- Polyhydramnios/diagnosis
- Pregnancy
- Pregnancy Complications
- Pregnancy Trimester, First
- Pregnancy Trimester, Second
- Trisomy
- Ultrasonography, Prenatal
Collapse
Affiliation(s)
- S K Hendricks
- Department of Obstetrics and Gynecology, University of Washington Medical Center, Seattle 98195
| | | | | | | | | | | | | |
Collapse
|
48
|
Abstract
The four-quadrant sum of amniotic fluid pockets (amniotic fluid index) was studied prospectively in 791 normal pregnancies. Interobserver and intraobserver variation was 3.1% and 6.7%, respectively. Logarithmic transformations were used to establish the mean and 90% confidence intervals for the amniotic fluid index at each week of gestation. In term pregnancies, the boundaries of the amniotic fluid index were 115 mm (mean), 68 to 196 mm (5th to 95th percentiles). In postdates pregnancies greater than 42 weeks, the values were 108 mm (mean), 67 to 174 mm (5th to 95th percentiles), p less than 0.0001. However, the values for each week were statistically distinct, indicating the need to reference amniotic fluid index measurements to week-specific normative tables for accurate interpretation. This study provides normative data for the amniotic fluid index throughout pregnancy.
Collapse
Affiliation(s)
- T R Moore
- Department of Obstetrics and Gynecology, U.S. Naval Hospital, San Diego, CA
| | | |
Collapse
|
49
|
Nagata S, Koyanagi T, Horimoto N, Satoh S, Nakano H. Chronological development of the fetal stomach assessed using real-time ultrasound. Early Hum Dev 1990; 22:15-22. [PMID: 2185928 DOI: 10.1016/0378-3782(90)90021-a] [Citation(s) in RCA: 19] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
To elucidate processes involved in the developing fetal stomach in utero, we examined chronological changes in maximum longitudinal and anteroposterior gastric dimensions in 618 fetuses from 16 to 41 weeks of gestation, using real-time ultrasound. Three statistically critical points were evident at 26-27, 32-33, and 36-37 weeks of gestation. Both dimensions increased from 16-17 to 26-27 weeks, remained fairly constant between 26-27 and 32-33 weeks, increased again from 32-33 to 36-37 weeks, and then decreased from 36-37 weeks onwards. These findings suggest that there are four different phases underlying the development of gastric function in the human fetus, corresponding to the time-periods divided by the three critical points of gestational age.
Collapse
Affiliation(s)
- S Nagata
- Department of Gynecology and Obstetrics, Faculty of Medicine, Kyushu University, Fukuoka, Japan
| | | | | | | | | |
Collapse
|
50
|
Elejalde BR, de Elejalde MM, Acuña JM, Thelen D, Trujillo C, Karrmann M. Prospective study of amniocentesis performed between weeks 9 and 16 of gestation: its feasibility, risks, complications and use in early genetic prenatal diagnosis. AMERICAN JOURNAL OF MEDICAL GENETICS 1990; 35:188-96. [PMID: 2309757 DOI: 10.1002/ajmg.1320350210] [Citation(s) in RCA: 82] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
This paper demonstrates that the outcome of amniocenteses performed between the 9th and the 14th weeks is similar to that of amniocenteses performed between the 15th and 20th weeks. We have performed and prospectively followed 615 amniocenteses between the 9th and 16th weeks of gestation. The outcome, risks, and complications are similar to those of amniocenteses at the usual time (after 15 weeks) and to the other groups of early amniocentesis (before 15 weeks). Early amniocentesis differs from amniocentesis at the usual time in that it carries higher rates of fetal losses and of amniotic fluid leakage, more confined cytogenetic abnormalities, and an increased number of patients who have the procedure postponed. Two cultures (0.32%) failed to produce results, 595 (96.7%) samples were obtained at the first tapping, 20 (3.3%) at the second attempt. alpha-Fetoprotein levels reach their maximum at 13 weeks. Amniocenteses between 15 and 16 weeks (293, or 47%) constitute the control group, those between 9 and 14 weeks (322) the experimental group. Early amniocentesis appears to be a safe early genetic prenatal diagnosis technique, an alternative to chorionic villi sampling.
Collapse
Affiliation(s)
- B R Elejalde
- Dept. Ob/Gyn, University of Wisconsin Medical School, Sinai Samaritan Medical Center, Milwaukee 53201
| | | | | | | | | | | |
Collapse
|