1
|
Hernandez-Andrade E, Ahn H, Szalai G, Korzeniewski SJ, Wang B, King M, Chaiworapongsa T, Than NG, Romero R. Evaluation of utero-placental and fetal hemodynamic parameters throughout gestation in pregnant mice using high-frequency ultrasound. ULTRASOUND IN MEDICINE & BIOLOGY 2014; 40:351-360. [PMID: 24342911 PMCID: PMC4179107 DOI: 10.1016/j.ultrasmedbio.2013.09.026] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/22/2012] [Revised: 08/09/2013] [Accepted: 09/22/2013] [Indexed: 06/03/2023]
Abstract
Throughout gestation, changes in maternal and fetal Doppler parameters in pregnant mice, similar to those obtained in human fetuses, were detected using high-frequency ultrasound with a 55-MHz linear probe. In the uterine arteries (UtA), fetal umbilical artery (UA) and fetal ductus venosus (DV) peak systolic velocity increased (UtA, p = 0.04; UA, p = 0.0004; DV, p = 0.02), end-diastolic velocity increased (UtA, p < 0.001; UA, p < 0.0001; DV, p = 0.01) and resistance index decreased (UtA, p = 0.0004; UA, p = 0.0001; DV, p = 0.04) toward the end of pregnancy. In the middle cerebral and carotid arteries, end diastolic velocity increased (p = 0.02 and p < 0.0001) and resistance index decreased (both vessels, p < 0.0001). There was a reduction in the pulsatile pattern in the umbilical vein (p < 0.05). The increased velocities and reduced resistance index suggest a progressive increment in blood flow to the fetal mouse toward the end of pregnancy. Fetal and utero-placental vascular parameters in CD-1 mice can be reliably evaluated using high-frequency ultrasound.
Collapse
Affiliation(s)
- Edgar Hernandez-Andrade
- Perinatology Research Branch, NICHD/NIH/DHHS, Bethesda, MD, and Detroit, MI, USA
- Department of Obstetrics and Gynecology, Wayne State University School of Medicine, Detroit, Michigan, USA
| | - Hyunyoung Ahn
- Perinatology Research Branch, NICHD/NIH/DHHS, Bethesda, MD, and Detroit, MI, USA
- Department of Obstetrics and Gynecology, Wayne State University School of Medicine, Detroit, Michigan, USA
| | - Gabor Szalai
- Perinatology Research Branch, NICHD/NIH/DHHS, Bethesda, MD, and Detroit, MI, USA
| | - Steven J Korzeniewski
- Perinatology Research Branch, NICHD/NIH/DHHS, Bethesda, MD, and Detroit, MI, USA
- Department of Obstetrics and Gynecology, Wayne State University School of Medicine, Detroit, Michigan, USA
| | - Bing Wang
- Perinatology Research Branch, NICHD/NIH/DHHS, Bethesda, MD, and Detroit, MI, USA
| | - Mary King
- Perinatology Research Branch, NICHD/NIH/DHHS, Bethesda, MD, and Detroit, MI, USA
- Department of Obstetrics and Gynecology, Wayne State University School of Medicine, Detroit, Michigan, USA
| | - Tinnakorn Chaiworapongsa
- Perinatology Research Branch, NICHD/NIH/DHHS, Bethesda, MD, and Detroit, MI, USA
- Department of Obstetrics and Gynecology, Wayne State University School of Medicine, Detroit, Michigan, USA
| | - Nandor Gabor Than
- Perinatology Research Branch, NICHD/NIH/DHHS, Bethesda, MD, and Detroit, MI, USA
- Department of Obstetrics and Gynecology, Wayne State University School of Medicine, Detroit, Michigan, USA
| | - Roberto Romero
- Perinatology Research Branch, NICHD/NIH/DHHS, Bethesda, MD, and Detroit, MI, USA
| |
Collapse
|
2
|
Bonel HM, Stolz B, Diedrichsen L, Frei K, Saar B, Tutschek B, Raio L, Surbek D, Srivastav S, Nelle M, Slotboom J, Wiest R. Diffusion-weighted MR imaging of the placenta in fetuses with placental insufficiency. Radiology 2011; 257:810-9. [PMID: 21084415 DOI: 10.1148/radiol.10092283] [Citation(s) in RCA: 84] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
PURPOSE To evaluate diffusion-weighted magnetic resonance (MR) imaging of the human placenta in fetuses with and fetuses without intrauterine growth restriction (IUGR) who were suspected of having placental insufficiency. MATERIALS AND METHODS The study was approved by the local ethics committee, and written informed consent was obtained. The authors retrospectively evaluated 1.5-T fetal MR images from 102 singleton pregnancies (mean gestation ± standard deviation, 29 weeks ± 5; range, 21-41 weeks). Morphologic and diffusion-weighted MR imaging were performed. A region of interest analysis of the apparent diffusion coefficient (ADC) of the placenta was independently performed by two observers who were blinded to clinical data and outcome. Placental insufficiency was diagnosed if flattening of the growth curve was detected at obstetric ultrasonography (US), if the birth weight was in the 10th percentile or less, or if fetal weight estimated with US was below the 10th percentile. Abnormal findings at Doppler US of the umbilical artery and histopathologic examination of specimens from the placenta were recorded. The ADCs in fetuses with placental insufficiency were compared with those in fetuses of the same gestational age without placental insufficiency and tested for normal distribution. The t tests and Pearson correlation coefficients were used to compare these results at 5% levels of significance. RESULTS Thirty-three of the 102 pregnancies were ultimately categorized as having an insufficient placenta. MR imaging depicted morphologic changes (eg, infarction or bleeding) in 27 fetuses. Placental dysfunction was suspected in 33 fetuses at diffusion-weighted imaging (mean ADC, 146.4 sec/mm(2) ± 10.63 for fetuses with placental insufficiency vs 177.1 sec/mm(2) ± 18.90 for fetuses without placental insufficiency; P < .01, with one false-positive case). The use of diffusion-weighted imaging in addition to US increased sensitivity for the detection of placental insufficiency from 73% to 100%, increased accuracy from 91% to 99%, and preserved specificity at 99%. CONCLUSION Placental dysfunction associated with growth restriction is associated with restricted diffusion and reduced ADC. A decreased ADC used as an early marker of placental damage might be indicative of pregnancy complications such as IUGR. SUPPLEMENTAL MATERIAL http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.10092283/-/DC1.
Collapse
Affiliation(s)
- Harald Marcel Bonel
- Institute for Diagnostic, Interventional and Pediatric Radiology, Inselspital, University of Bern, Freiburgstrasse 10, 3010 Bern, Switzerland.
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
3
|
Abstract
This year marks the 250th anniversary of the discovery by William Hunter of the existence of two distinct circulations within the human placenta. Until relatively recently the placenta has been viewed with “respect” – a passive structure which occasionally elicited fear and anxiety if implanted either too low or too deep. More recently our understanding of perinatal physiology, blood flow regulation and epidemiological data linking prenatal events with adult disease has created renewed interest in the placenta. This review will focus on the regulation of fetal blood flow in the placenta, the possible mechanisms whereby it may be deranged and why this might be relevant to adult disease.
Collapse
|
4
|
Acharya G, Wilsgaard T, Berntsen GKR, Maltau JM, Kiserud T. Doppler-derived umbilical artery absolute velocities and their relationship to fetoplacental volume blood flow: a longitudinal study. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2005; 25:444-453. [PMID: 15816007 DOI: 10.1002/uog.1880] [Citation(s) in RCA: 31] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
OBJECTIVES To construct reference ranges for serial measurements of the umbilical artery (UA) absolute blood flow velocities in the second half of pregnancy and to test the hypothesis that significant associations exist between UA velocities and placental volume blood flow assessed from umbilical vein blood flow velocities and diameter. METHODS This was a prospective longitudinal study of the umbilical circulation. UA absolute velocities and umbilical vein blood flow were measured at 4-weekly intervals between 19 and 42 weeks' gestation in 130 low-risk singleton pregnancies. A total of 511 observations were used to construct the reference ranges and assess the association between UA absolute velocities and placental volume flow using multilevel modeling. RESULTS Both UA absolute velocities and placental volume blood flow showed a steady increase throughout the second half of pregnancy. However, the gestational age-related increase in the UA end-diastolic velocity (EDV) was greater than the corresponding increase in the peak systolic velocity (PSV). The time-averaged intensity-weighted mean velocity (TAWMV)/time-averaged maximum velocity (TAMXV) was 0.6 indicating probably not a completely parabolic velocity profile. There was a significant positive association (P < 0.00001) between UA absolute velocities and placental volume blood flow, but this association was modified by the gestational age. The intraobserver coefficients of variation for the UA PSV, EDV, TAMXV and TAWMV and placental volume blood flow were 10.17%, 16.29%, 11.46%, 18.18% and 8.61%, respectively. CONCLUSION We have established new reference ranges for the UA absolute velocities based on longitudinal data. They show a significant association with fetoplacental volume blood flow and may have a clinical value in the assessment of the umbilical circulation.
Collapse
Affiliation(s)
- G Acharya
- Department of Obstetrics and Gynecology, University Hospital of Northern Norway, Tromsø, Norway.
| | | | | | | | | |
Collapse
|
5
|
Di Naro E, Raio L, Ghezzi F, Franchi M, Romano F, Addario VD. Longitudinal umbilical vein blood flow changes in normal and growth-retarded fetuses. Acta Obstet Gynecol Scand 2002. [DOI: 10.1034/j.1600-0412.2002.810609.x] [Citation(s) in RCA: 47] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
6
|
Sterne G, Shields LE, Dubinsky TJ. Abnormal fetal cerebral and umbilical Doppler measurements in fetuses with intrauterine growth restriction predicts the severity of perinatal morbidity. JOURNAL OF CLINICAL ULTRASOUND : JCU 2001; 29:146-151. [PMID: 11329157 DOI: 10.1002/1097-0096(200103/04)29:3<146::aid-jcu1014>3.0.co;2-i] [Citation(s) in RCA: 35] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
PURPOSE This prospective study was performed to determine if the ratio of the middle cerebral artery (MCA) S/D ratio (ratio of peak systolic blood flow velocity to diastolic velocity) to the umbilical artery (UA) S/D ratio (MCA/UA S/D ratio) predicts the degree of neonatal morbidity in fetuses suspected of having intrauterine growth restriction (IUGR). METHODS Sixty-one fetuses were identified prospectively by sonography as having an estimated fetal weight below the 10th percentile for gestational age. The 61 fetuses underwent Doppler sonography in the third trimester and then were stratified into 3 groups based on the MCA/UA S/D ratio: group A, MCA/UA S/D ratio > 1.0 (controls; n = 37); group B, MCA/UA S/D ratio < or = 1.0 (intracerebral blood flow redistribution; n = 16); and group C, reversed or absent UA diastolic flow (n = 8). Outcome variables assessed included gestational age at delivery, birth weight, UA pH, mode of delivery, respiratory distress syndrome requiring intubation, and intracranial hemorrhage. RESULTS The mean MCA/UA S/D ratios in groups A and B were 1.69 + /- 0.61 and 0.59 + /- 0.24, respectively (p < 0.01). The mean gestational ages at delivery for groups A, B, and C were 34.7, 33.2, and 29.0 weeks, respectively. The mean birth weights were below the fifth percentile for age for groups B and C and significantly related to the severity of abnormal Doppler findings (p < 0.01) after correction for age. Mean UA pHs were 7.25 + /- 0.01, 7.19 + /- 0.01, and 7.14 + /- 0.13 for groups A, B, and C, respectively, with significant differences between groups A and B (p < 0.05) and groups A and C (p < 0.05). Respiratory distress syndrome and intracranial hemorrhage were not associated with abnormal Doppler findings after correction for gestational age. The interval between the abnormal Doppler examination and delivery (p < 0.001) and the occurrence of fetal distress requiring cesarean section (p < 0.001) were significantly related to the severity of Doppler findings. CONCLUSIONS In fetuses with suspected IUGR, abnormal MCA/UA S/D ratios are strongly associated with low gestational age at delivery, low birth weight, and low UA pH. Abnormal MCA/UA S/D ratios are also significantly associated with shorter interval to delivery and the need for emergent delivery.
Collapse
Affiliation(s)
- G Sterne
- Department of Radiology, Virginia Mason Medical Center, 1100 Ninth Avenue, Seattle, Washington 9810, USA
| | | | | |
Collapse
|
7
|
Galan HL, Jozwik M, Rigano S, Regnault TR, Hobbins JC, Battaglia FC, Ferrazzi E. Umbilical vein blood flow determination in the ovine fetus: comparison of Doppler ultrasonographic and steady-state diffusion techniques. Am J Obstet Gynecol 1999; 181:1149-53. [PMID: 10561635 DOI: 10.1016/s0002-9378(99)70098-0] [Citation(s) in RCA: 53] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Abstract
OBJECTIVE This study was undertaken to assess the accuracy of triplex ultrasonographic measurement of venous umbilical blood flow in comparison with the steady-state diffusion technique and to determine the impact of cotyledon weight and number on umbilical blood flow. STUDY DESIGN Six late-gestation ewes with long-term catheter placement were studied for venous umbilical blood flow with the ethanol steady-state diffusion technique and with triplex-mode ultrasonography (color Doppler, pulsed-wave Doppler, and real-time ultrasonography). At necropsy the number and weight of the cotyledons serving each umbilical vein were recorded. RESULTS Umbilical blood flow determined by triplex-mode ultrasonography (207. 5 +/- 8.6 mL. kg(-1) fetus. min(-1)) was virtually identical to that determined with the steady-state diffusion technique (208.1 +/- 7.3 mL. kg(-1) fetus. min(-1); P =.9). When values were normalized for the weight or number of cotyledons serving each vein, there was no difference in umbilical blood flow between small and large umbilical veins in all the sheep. CONCLUSIONS Our study validates the accuracy of the triplex ultrasonographic method and provides justification for its use in future human investigations. In absolute terms umbilical blood flow frequently differs between the 2 veins. When expressed per number or mass of cotyledons, however, the umbilical blood flows are similar.
Collapse
Affiliation(s)
- H L Galan
- Division of Perinatal Medicine, Department of Obstetrics and Gynecology, University of Colorado, Denver 80262, USA
| | | | | | | | | | | | | |
Collapse
|
8
|
Gagnon R, Johnston L, Murotsuki J. Fetal placental embolization in the late-gestation ovine fetus: alterations in umbilical blood flow and fetal heart rate patterns. Am J Obstet Gynecol 1996; 175:63-72. [PMID: 8694077 DOI: 10.1016/s0002-9378(96)70252-1] [Citation(s) in RCA: 42] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
OBJECTIVE Our goal was to determine the effect of chronic and acute umbilical-placental embolization on placental hemodynamic and fetal heart rate patterns in relation to fetal oxygenation in the near-term ovine fetus. STUDY DESIGN Daily fetal placental embolization was performed during 10 days in 9 sheep fetuses until fetal arterial oxygen content decreased by approximately 30%. Nine control fetuses received saline solution. Mean and pulsatile umbilical blood flow, perfusion pressure, placental vascular resistance, fundamental impedance, pressure pulsatility index, and umbilical artery resistance index corrected to a fetal heart rate of 160 beats/min were measured. On day 10 both groups were acutely embolized until fetal arterial pH decreased to approximately 7.00. Fetal heart rate was measured with the Sonicaid System 8000 (Oxford Sonicaid, Oxford, United Kingdom). RESULTS Chronic fetal placental embolization was associated with a progressive reduction in umbilical blood flow (p < 0.00001) and fetal arterial oxygen content (p < 0.001) whereas fetal heart rate patterns remained unaltered. A chronic increase in umbilical artery resistance index corrected to a fetal heart rate of 160 beats/min could be entirely explained only if the changes in umbilical artery pressure pulsatility index and the fundamental impedance were taken into account, in addition to the changes observed in placental vascular resistance. During acute embolization leading to a 50% reduction in umbilical blood flow (p < 0.0002) and a three times increase in placental vascular resistance (p < 0.0001), the most consistent change in fetal heart rate patterns related to progressive metabolic acidosis was an 84% decrease in absolute acceleration frequency (p < 0.0001) whereas short-term fetal heart rate variability remained unaltered. CONCLUSION Changes in umbilical artery resistance index induced by chronic umbilical-placental embolization resulting in fetal hypoxemia occurred before any changes in fetal heart rate patterns were detectable. A decrease in the absolute acceleration frequency was the only component of fetal heart rate patterns related to progressive metabolic acidosis in the near-term ovine fetus.
Collapse
Affiliation(s)
- R Gagnon
- Department of Obstetrics and Gynaecology, St. Joseph's Health Centre, London, Ontario, Canada
| | | | | |
Collapse
|
9
|
Joern H, Funk A, Goetz M, Kuehlwein H, Klein A, Fendel H. Development of quantitative Doppler indices for uteroplacental and fetal blood flow during the third trimester. ULTRASOUND IN MEDICINE & BIOLOGY 1996; 22:823-835. [PMID: 8923702 DOI: 10.1016/0301-5629(96)00090-7] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
Abstract
The aim of our study was to describe the development of uteroplacental and fetal blood flow during the third trimester. Doppler examination was carried out on 393 uncomplicated pregnancies with uncomplicated term delivery. Using a pulsed color Doppler, we calculated the maximum systolic, mean and maximum end-diastolic velocity after correcting the angle of insonation. Patients under tocolysis or other medication influencing blood flow parameters were excluded from this cross-sectional study. Summarizing the results gained by Doppler ultrasound investigation of the uteroplacental and fetal blood vessels, we created quantiles as quantitative Doppler indices for the maximum systolic, mean (TAMX = time averaged maximum velocity) and maximum end-diastolic velocity. The following conclusions could be drawn: (1) resistance to the blood flow in the maternal portion of the placenta does not change during the third trimester; (2) resistance to the blood flow on the fetal side of the placenta decreases up to week 42 of gestation; (3) cerebral vascular resistance decreases constantly up to gestational week 42; and (4) vascular resistance to the blood flow of the kidney decreases only slightly during the third trimester. This study offers clinically important values for quantitative Doppler flow velocimetry for the first time. We hope that our findings improve the usefulness of Doppler ultrasound as a diagnostic tool in obstetrical management.
Collapse
Affiliation(s)
- H Joern
- Department of Obstetrics and Gynaecology, Technical University of Aachen, Germany
| | | | | | | | | | | |
Collapse
|
10
|
Arias F. Accuracy of the middle-cerebral-to-umbilical-artery resistance index ratio in the prediction of neonatal outcome in patients at high risk for fetal and neonatal complications. Am J Obstet Gynecol 1994; 171:1541-5. [PMID: 7802064 DOI: 10.1016/0002-9378(94)90398-0] [Citation(s) in RCA: 64] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Abstract
OBJECTIVE The purpose of this study was to determine the accuracy of the middle-cerebral-to-umbilical-artery resistance index ratio in the prediction of fetal outcome in pregnancies at high risk for fetal and neonatal morbidity and mortality. STUDY DESIGN A prospective controlled nonrandomized study was conducted in the high-risk pregnancy unit of a teaching hospital. The control group was formed by 20 healthy women with uncomplicated singleton pregnancies and healthy children delivered at term. The study group consisted of 115 women referred to the high-risk pregnancy unit because of a variety of pregnancy complications. Longitudinal evaluation of the control group and cross-sectional evaluation of the study group were carried out at different gestational ages by means of duplex Doppler ultrasonography. The main outcome measures were fetal growth retardation, preterm birth, and neonatal morbidity. RESULTS The middle-cerebral-to-umbilical-artery ratio remains relatively constant (mean +/- SD 1.33 +/- 0.19) between 27 and 37 weeks. A cutoff value of 1.0 (sensitivity 57.9%, specificity 75.6%, false-positive rate 24.4%) was selected from the receiver-operator characteristic curve analysis. This cutoff value successfully identified a population at significant risk of fetal growth retardation (relative risk 3.07, 95% confidence interval 1.73 to 5.45, exact two-tailed p = 0.0009) and severe neonatal morbidity (Mann-Whitney U = 463.5, two-tailed p = 0.03). The middle-cerebral-to-umbilical-artery ratio was not useful in the prediction of preterm birth. CONCLUSIONS A middle-cerebral-to-umbilical-artery ratio of < or = 1.0 identifies a subgroup of patients at high risk for fetal growth retardation and severe neonatal morbidity.
Collapse
Affiliation(s)
- F Arias
- Division of Maternal-Fetal Medicine, St. John's Mercy Medical Center, St. Louis, MO 63141
| |
Collapse
|
11
|
Shiraishi H, Silverman NH, Rudolph AM. Accuracy of right ventricular output estimated by Doppler echocardiography in the sheep fetus. Am J Obstet Gynecol 1993; 168:947-53. [PMID: 8456908 DOI: 10.1016/s0002-9378(12)90851-0] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Abstract
OBJECTIVE Our goal was to determine whether Doppler ultrasonographic estimation of fetal right ventricular output was accurate enough to evaluate fetal cardiac performance before the technique can be applied with confidence to the human fetus. The accuracy of this method has not been validated experimentally. STUDY DESIGN We compared the right ventricular output measured by Doppler echocardiography with that determined from a transit-time ultrasonic flowmeter placed around the fetal pulmonary trunk and to that determined by microsphere technique. We obtained 72 Doppler flow measurements and 16 microsphere flow measurements in six fetuses. RESULTS There was a fair correlation between cardiac output estimated by Doppler echocardiography performed transabdominally and that determined by a transit-time flowmeter (r = 0.76). The correlation was excellent when Doppler echocardiography was performed by the trans-uterine approach (r = 0.94). There was also an excellent correlation between right ventricular output determined by a transit-time flowmeter and that by microsphere technique (r = 0.94). CONCLUSION Doppler echocardiographic estimation of fetal right ventricular cardiac output is thus feasible and accurate.
Collapse
Affiliation(s)
- H Shiraishi
- Department of Pediatrics, University of California, San Francisco
| | | | | |
Collapse
|
12
|
Atrial natriuretic peptide: A new hormone in the fetoplacental arterial circulation. Placenta 1993. [DOI: 10.1016/s0143-4004(05)80291-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|