1
|
Antoniac I, Manescu (Paltanea) V, Antoniac A, Paltanea G. Magnesium-based alloys with adapted interfaces for bone implants and tissue engineering. Regen Biomater 2023; 10:rbad095. [PMID: 38020233 PMCID: PMC10664085 DOI: 10.1093/rb/rbad095] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2023] [Revised: 10/03/2023] [Accepted: 10/22/2023] [Indexed: 12/01/2023] Open
Abstract
Magnesium and its alloys are one of the most used materials for bone implants and tissue engineering. They are characterized by numerous advantages such as biodegradability, high biocompatibility and mechanical properties with values close to the human bone. Unfortunately, the implant surface must be adequately tuned, or Mg-based alloys must be alloyed with other chemical elements due to their increased corrosion effect in physiological media. This article reviews the clinical challenges related to bone repair and regeneration, classifying bone defects and presenting some of the most used and modern therapies for bone injuries, such as Ilizarov or Masquelet techniques or stem cell treatments. The implant interface challenges are related to new bone formation and fracture healing, implant degradation and hydrogen release. A detailed analysis of mechanical properties during implant degradation is extensively described based on different literature studies that included in vitro and in vivo tests correlated with material properties' characterization. Mg-based trauma implants such as plates and screws, intramedullary nails, Herbert screws, spine cages, rings for joint treatment and regenerative scaffolds are presented, taking into consideration their manufacturing technology, the implant geometrical dimensions and shape, the type of in vivo or in vitro studies and fracture localization. Modern technologies that modify or adapt the Mg-based implant interfaces are described by presenting the main surface microstructural modifications, physical deposition and chemical conversion coatings. The last part of the article provides some recommendations from a translational perspective, identifies the challenges associated with Mg-based implants and presents some future opportunities. This review outlines the available literature on trauma and regenerative bone implants and describes the main techniques used to control the alloy corrosion rate and the cellular environment of the implant.
Collapse
Affiliation(s)
- Iulian Antoniac
- Faculty of Material Science and Engineering, National University of Science and Technology POLITEHNICA Bucharest, 060042 Bucharest, Romania
- Academy of Romanian Scientists, 050094 Bucharest, Romania
| | - Veronica Manescu (Paltanea)
- Faculty of Material Science and Engineering, National University of Science and Technology POLITEHNICA Bucharest, 060042 Bucharest, Romania
- Faculty of Electrical Engineering, National University of Science and Technology POLITEHNICA Bucharest, 060042 Bucharest, Romania
| | - Aurora Antoniac
- Faculty of Material Science and Engineering, National University of Science and Technology POLITEHNICA Bucharest, 060042 Bucharest, Romania
| | - Gheorghe Paltanea
- Faculty of Electrical Engineering, National University of Science and Technology POLITEHNICA Bucharest, 060042 Bucharest, Romania
| |
Collapse
|
2
|
Nyirjesy SC, Heller M, von Windheim N, Gingras A, Kang SY, Ozer E, Agrawal A, Old MO, Seim NB, Carrau RL, Rocco JW, VanKoevering KK. The role of computer aided design/computer assisted manufacturing (CAD/CAM) and 3- dimensional printing in head and neck oncologic surgery: A review and future directions. Oral Oncol 2022; 132:105976. [PMID: 35809506 DOI: 10.1016/j.oraloncology.2022.105976] [Citation(s) in RCA: 17] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2022] [Accepted: 06/17/2022] [Indexed: 01/12/2023]
Abstract
Microvascular free flap reconstruction has remained the standard of care in reconstruction of large tissue defects following ablative head and neck oncologic surgery, especially for bony structures. Computer aided design/computer assisted manufacturing (CAD/CAM) and 3-dimensionally (3D) printed models and devices offer novel solutions for reconstruction of bony defects. Conventional free hand techniques have been enhanced using 3D printed anatomic models for reference and pre-bending of titanium reconstructive plates, which has dramatically improved intraoperative and microvascular ischemia times. Improvements led to current state of the art uses which include full virtual planning (VP), 3D printed osteotomy guides, and patient specific reconstructive plates, with advanced options incorporating dental rehabilitation and titanium bone replacements into the primary surgical plan through use of these tools. Limitations such as high costs and delays in device manufacturing may be mitigated with in house software and workflows. Future innovations still in development include printing custom prosthetics, 'bioprinting' of tissue engineered scaffolds, integration of therapeutic implants, and other possibilities as this technology continues to rapidly advance. This review summarizes the literature and serves as a summary guide to the historic, current, advanced, and future possibilities of 3D printing within head and neck oncologic surgery and bony reconstruction. This review serves as a summary guide to the historic, current, advanced, and future roles of CAD/CAM and 3D printing within the field of head and neck oncologic surgery and bony reconstruction.
Collapse
Affiliation(s)
- Sarah C Nyirjesy
- Department of Otolaryngology- Head and Neck Surgery, The James Cancer Hospital and Solove Research Institute, The Ohio State University Wexner Medical Center, 915 Olentangy River Road, Columbus, OH 43210, United States
| | - Margaret Heller
- Department of Otolaryngology- Head and Neck Surgery, The James Cancer Hospital and Solove Research Institute, The Ohio State University Wexner Medical Center, 915 Olentangy River Road, Columbus, OH 43210, United States
| | - Natalia von Windheim
- Department of Otolaryngology- Head and Neck Surgery, The James Cancer Hospital and Solove Research Institute, The Ohio State University Wexner Medical Center, 915 Olentangy River Road, Columbus, OH 43210, United States
| | - Amelia Gingras
- Department of Otolaryngology- Head and Neck Surgery, The James Cancer Hospital and Solove Research Institute, The Ohio State University Wexner Medical Center, 915 Olentangy River Road, Columbus, OH 43210, United States
| | - Stephen Y Kang
- Department of Otolaryngology- Head and Neck Surgery, The James Cancer Hospital and Solove Research Institute, The Ohio State University Wexner Medical Center, 915 Olentangy River Road, Columbus, OH 43210, United States
| | - Enver Ozer
- Department of Otolaryngology- Head and Neck Surgery, The James Cancer Hospital and Solove Research Institute, The Ohio State University Wexner Medical Center, 915 Olentangy River Road, Columbus, OH 43210, United States
| | - Amit Agrawal
- Department of Otolaryngology- Head and Neck Surgery, The James Cancer Hospital and Solove Research Institute, The Ohio State University Wexner Medical Center, 915 Olentangy River Road, Columbus, OH 43210, United States
| | - Matthew O Old
- Department of Otolaryngology- Head and Neck Surgery, The James Cancer Hospital and Solove Research Institute, The Ohio State University Wexner Medical Center, 915 Olentangy River Road, Columbus, OH 43210, United States
| | - Nolan B Seim
- Department of Otolaryngology- Head and Neck Surgery, The James Cancer Hospital and Solove Research Institute, The Ohio State University Wexner Medical Center, 915 Olentangy River Road, Columbus, OH 43210, United States
| | - Ricardo L Carrau
- Department of Otolaryngology- Head and Neck Surgery, The James Cancer Hospital and Solove Research Institute, The Ohio State University Wexner Medical Center, 915 Olentangy River Road, Columbus, OH 43210, United States
| | - James W Rocco
- Department of Otolaryngology- Head and Neck Surgery, The James Cancer Hospital and Solove Research Institute, The Ohio State University Wexner Medical Center, 915 Olentangy River Road, Columbus, OH 43210, United States
| | - Kyle K VanKoevering
- Department of Otolaryngology- Head and Neck Surgery, The James Cancer Hospital and Solove Research Institute, The Ohio State University Wexner Medical Center, 915 Olentangy River Road, Columbus, OH 43210, United States.
| |
Collapse
|
3
|
Vujović S, Desnica J, Stanišić D, Ognjanović I, Stevanovic M, Rosic G. Applications of Biodegradable Magnesium-Based Materials in Reconstructive Oral and Maxillofacial Surgery: A Review. Molecules 2022; 27:molecules27175529. [PMID: 36080296 PMCID: PMC9457564 DOI: 10.3390/molecules27175529] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2022] [Revised: 08/19/2022] [Accepted: 08/25/2022] [Indexed: 11/17/2022] Open
Abstract
Reconstruction of defects in the maxillofacial region following traumatic injuries, craniofacial deformities, defects from tumor removal, or infections in the maxillofacial area represents a major challenge for surgeons. Various materials have been studied for the reconstruction of defects in the maxillofacial area. Biodegradable metals have been widely researched due to their excellent biological properties. Magnesium (Mg) and Mg-based materials have been extensively studied for tissue regeneration procedures due to biodegradability, mechanical characteristics, osteogenic capacity, biocompatibility, and antibacterial properties. The aim of this review was to analyze and discuss the applications of Mg and Mg-based materials in reconstructive oral and maxillofacial surgery in the fields of guided bone regeneration, dental implantology, fixation of facial bone fractures and soft tissue regeneration.
Collapse
Affiliation(s)
- Sanja Vujović
- Department of Dentistry, Faculty of Medical Sciences, University of Kragujevac, Svetozara Markovića 69, 34000 Kragujevac, Serbia
| | - Jana Desnica
- Department of Dentistry, Faculty of Medical Sciences, University of Kragujevac, Svetozara Markovića 69, 34000 Kragujevac, Serbia
| | - Dragana Stanišić
- Department of Dentistry, Faculty of Medical Sciences, University of Kragujevac, Svetozara Markovića 69, 34000 Kragujevac, Serbia
| | - Irena Ognjanović
- Department of Dentistry, Faculty of Medical Sciences, University of Kragujevac, Svetozara Markovića 69, 34000 Kragujevac, Serbia
| | - Momir Stevanovic
- Department of Dentistry, Faculty of Medical Sciences, University of Kragujevac, Svetozara Markovića 69, 34000 Kragujevac, Serbia
- Correspondence: (M.S.); (G.R.); Tel.: +381-641-327752 (M.S.); +381-633-92812 (G.R.)
| | - Gvozden Rosic
- Department of Physiology, Faculty of Medical Sciences, University of Kragujevac, Svetozara Markovića 69, 34000 Kragujevac, Serbia
- Correspondence: (M.S.); (G.R.); Tel.: +381-641-327752 (M.S.); +381-633-92812 (G.R.)
| |
Collapse
|
4
|
Biodegradable magnesium barrier membrane used for guided bone regeneration in dental surgery. Bioact Mater 2022; 14:152-168. [PMID: 35310351 PMCID: PMC8892166 DOI: 10.1016/j.bioactmat.2021.11.018] [Citation(s) in RCA: 16] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2021] [Revised: 10/26/2021] [Accepted: 11/12/2021] [Indexed: 12/30/2022] Open
Abstract
Barrier membranes are commonly used as part of the dental surgical technique guided bone regeneration (GBR) and are often made of resorbable collagen or non-resorbable materials such as PTFE. While collagen membranes do not provide sufficient mechanical protection of the covered bone defect, titanium reinforced membranes and non-resorbable membranes need to be removed in a second surgery. Thus, biodegradable GBR membranes made of pure magnesium might be an alternative. In this study a biodegradable pure magnesium (99.95%) membrane has been proven to have all of the necessary requirements for an optimal regenerative outcome from both a mechanical and biological perspective. After implantation, the magnesium membrane separates the regenerating bone from the overlying, faster proliferating soft tissue. During the initial healing period, the membrane maintained a barrier function and space provision, whilst retaining the positioning of the bone graft material within the defect space. As the magnesium metal corroded, it formed a salty corrosion layer and local gas cavities, both of which extended the functional lifespan of the membrane barrier capabilities. During the resorption of the magnesium metal and magnesium salts, it was observed that the membrane became surrounded and then replaced by new bone. After the membrane had completely resorbed, only healthy tissue remained. The in vivo performance study demonstrated that the magnesium membrane has a comparable healing response and tissue regeneration to that of a resorbable collagen membrane. Overall, the magnesium membrane demonstrated all of the ideal qualities for a barrier membrane used in GBR treatment. First report on a biodegradable metallic barrier membrane for use in oral surgery is presented. The mechanical stability of the metallic barrier membrane provides a careful shielding of the augmented bone defect. Full resorption of metallic barrier membrane and bone healing is completed long before current standards for second surgical patient treatment.
Collapse
|
5
|
Titanium or Biodegradable Osteosynthesis in Maxillofacial Surgery? In Vitro and In Vivo Performances. Polymers (Basel) 2022; 14:polym14142782. [PMID: 35890557 PMCID: PMC9316877 DOI: 10.3390/polym14142782] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2022] [Revised: 06/30/2022] [Accepted: 07/02/2022] [Indexed: 02/06/2023] Open
Abstract
Osteosynthesis systems are used to fixate bone segments in maxillofacial surgery. Titanium osteosynthesis systems are currently the gold standard. However, the disadvantages result in symptomatic removal in up to 40% of cases. Biodegradable osteosynthesis systems, composed of degradable polymers, could reduce the need for removal of osteosynthesis systems while avoiding the aforementioned disadvantages of titanium osteosyntheses. However, disadvantages of biodegradable systems include decreased mechanical properties and possible foreign body reactions. In this review, the literature that focused on the in vitro and in vivo performances of biodegradable and titanium osteosyntheses is discussed. The focus was on factors underlying the favorable clinical outcome of osteosyntheses, including the degradation characteristics of biodegradable osteosyntheses and the host response they elicit. Furthermore, recommendations for clinical usage and future research are given. Based on the available (clinical) evidence, biodegradable copolymeric osteosyntheses are a viable alternative to titanium osteosyntheses when applied to treat maxillofacial trauma, with similar efficacy and significantly lower symptomatic osteosynthesis removal. For orthognathic surgery, biodegradable copolymeric osteosyntheses are a valid alternative to titanium osteosyntheses, but a longer operation time is needed. An osteosynthesis system composed of an amorphous copolymer, preferably using ultrasound welding with well-contoured shapes and sufficient mechanical properties, has the greatest potential as a biocompatible biodegradable copolymeric osteosynthesis system. Future research should focus on surface modifications (e.g., nanogel coatings) and novel biodegradable materials (e.g., magnesium alloys and silk) to address the disadvantages of current osteosynthesis systems.
Collapse
|
6
|
Biodegradation of a Magnesium Alloy Fixation Screw Used in a Guided Bone Regeneration Model in Beagle Dogs. MATERIALS 2022; 15:ma15124111. [PMID: 35744169 PMCID: PMC9229971 DOI: 10.3390/ma15124111] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/06/2022] [Revised: 06/03/2022] [Accepted: 06/08/2022] [Indexed: 02/06/2023]
Abstract
Nowadays, the most commonly used fixation systems are non-resorbable, but new resorbable magnesium alloy fixation screws have been introduced recently. Therefore, the aim of this study was to compare the magnesium fixation screw and the commonly used non-resorbable titanium screw in an animal model. Four 3-wall defect sites were covered with collagen membranes in the mandible of twenty beagle dogs (two sites on the left and two on the right). Each membrane was fixed with either four magnesium screws or four titanium screws. Post-operative follow-up revealed the expected observations such as transient inflammation and pain. Both groups showed a good healing response, with no differences between groups. Micro-CT analysis showed no significant difference between groups in terms of BV/TV or soft tissue volume. The void volume in the magnesium fixation screw group continued to decrease on average between the different timepoints, but not significantly. Furthermore, a gradual progression of the degradation process of the magnesium screws was observed in the same group. Magnesium screws and titanium screws showed equal performance in tissue regeneration according to GBR principles. An additional advantage of magnesium screws is their resorbable nature, which eliminates the need for a second surgical step to remove the screws.
Collapse
|
7
|
Dargusch MS, Balasubramani N, Yang N, Johnston S, Ali Y, Wang G, Venezuela J, Carluccio J, Lau C, Allavena R, Liang D, Mardon K, Ye Q. In vivo performance of a rare earth free Mg–Zn–Ca alloy manufactured using twin roll casting for potential applications in the cranial and maxillofacial fixation devices. Bioact Mater 2022; 12:85-96. [PMID: 35087965 PMCID: PMC8777300 DOI: 10.1016/j.bioactmat.2021.10.026] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2021] [Revised: 09/24/2021] [Accepted: 10/18/2021] [Indexed: 12/20/2022] Open
Abstract
A magnesium alloy containing essential, non-toxic, biodegradable elements such as Ca and Zn has been fabricated using a novel twin-roll casting process (TRC). Microstructure, mechanical properties, in vivo corrosion and biocompatibility have been assessed and compared to the properties of the rare earth (RE) element containing WE43 alloy. TRC Mg-0.5 wt% Zn- 0.5 wt% Ca exhibited fine grains with an average grain size ranging from 70 to 150 μm. Mechanical properties of a TRC Mg-0.5Zn-0.5Ca alloy showed an ultimate tensile strength of 220 MPa and ductility of 9.3%. The TRC Mg-0.5Zn-0.5Ca alloy showed a degradation rate of 0.51 ± 0.07 mm/y similar to that of the WE43 alloy (0.47 ± 0.09 mm/y) in the rat model after 1 week of implantation. By week 4 the biodegradation rates of both alloys studied were lowered and stabilized with fewer gas pockets around the implant. The histological analysis shows that both WE43 and TRC Mg-0.5Zn-0.5Ca alloy triggered comparable tissue healing responses at respective times of implantation. The presence of more organized scarring tissue around the TRC Mg-0.5Zn-0.5Ca alloys suggests that the biodegradation of the RE-free alloy may be more conducive to the tissue proliferation and remodelling process. Mg-0.5Zn-0.5Ca alloy plates were fabricated by a twin-roll casting (TRC) process. TRC alloy showed an ultimate strength and elongation of 221 ± 2 MPa and 9 ± 2%. Gas development during in vivo degradation was analysed using μ-CT techniques. Histological analysis revealed a good biocompatibility and promoted healing.
Collapse
|
8
|
Feasibility and Efficacy of a Degradable Magnesium-Alloy GBR Membrane for Bone Augmentation in a Distal Bone-Defect Model in Beagle Dogs. Bioinorg Chem Appl 2022; 2022:4941635. [PMID: 35371192 PMCID: PMC8967573 DOI: 10.1155/2022/4941635] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2022] [Accepted: 03/05/2022] [Indexed: 01/29/2023] Open
Abstract
We explored the feasibility and efficacy of a degradable magnesium (Mg) alloy guided bone regeneration (GBR) in the treatment of bone defects after tooth extraction. A GBR membrane (MAR-Gide (MG)) was used to treat a mandibular second molar (M2M)-distal bone defect (DBD). In eight beagle dogs, bilateral mandibular second and fourth premolars were hemi-sected. The distal roots were removed to create a two-wall bony defect of dimension 5 mm × 5 mm × 5 mm to simulate M2M-DBD. Thirty-two bone defects were assigned randomly into four groups according to GBR membranes (MG and Bio-Gide (BG)) applied and the time of killing (3 months and 6 months after surgery). The osteogenesis of bone defects and MG degradation were analyzed using micro-CT, histology (staining, tartrate-resistant acid phosphatase), and inductively coupled plasma mass spectrometry. MG did not increase the prevalence of infection, wound dehiscence, or subcutaneous emphysema compared with those using BG. Trabecular volume/total volume at 3 months (63.71 ± 10.4% vs. 59.97 ± 8.94%) was significantly higher in the group MG than that in the group BG. Implanted MG was degraded completely within 3 months, and "island-shaped" new bone was found near MG degradation products. A significant difference was not found in vertical bone height or percent of new bone formation (45.44 ± 12.28% vs. 43.49 ± 7.12%) between the groups. The concentration of rare-earth elements in mandibular lymph nodes of the group MG was significantly higher than that of the group BG (P ≤ 0.017) but did not lead to histopathological changes. In summary, MG exhibited good biocompatibility and clinical applicability compared with BG in vivo. The osteogenic effect of MG could be enhanced by regulating the degradation rate of Mg-alloy.
Collapse
|
9
|
Kozakiewicz M, Gabryelczak I. Bone Union Quality after Fracture Fixation of Mandibular Head with Compression Magnesium Screws. MATERIALS (BASEL, SWITZERLAND) 2022; 15:2230. [PMID: 35329682 PMCID: PMC8950275 DOI: 10.3390/ma15062230] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/23/2022] [Revised: 02/13/2022] [Accepted: 03/15/2022] [Indexed: 12/22/2022]
Abstract
For some years now, fixation devices created with resorbable magnesium alloys for the mandibular head have been clinically available and are beginning to be used. It is thus valuable to evaluate the quality of unions in these cases. The aim of this study was radiological comparison of magnesium versus titanium open reduction and rigid fixations in the mandible condylar head. Thirty-one patients were treated for fractures of the mandibular head with magnesium WE43 alloy headless compression screws (diameter 2.3 mm) and, as a reference group, 29 patients were included with similar construction titanium screws (diameter 1.8 mm). The 12-month results of the treatment were evaluated by the texture analysis of CT. Near similar treatment results were found with magnesium screws in traditional titanium fixation. Magnesium screws result in a higher density of the bone structure in the mandibular head. Conclusions: The quantitative evaluation of bone union after surgical treatment of mandibular head fracture with magnesium compression headless screws indicates that stable consolidation was achieved. Undoubtedly, the resorption process of the screws was found to be incomplete after 12 months, evidenced by a marked densification of the bone structure at the fracture site.
Collapse
Affiliation(s)
- Marcin Kozakiewicz
- Department of Maxillofacial Surgery, Medical University of Lodz, 113 Żeromskiego Str., 90-549 Lodz, Poland;
| | | |
Collapse
|
10
|
Gautam S, Bhatnagar D, Bansal D, Batra H, Goyal N. Recent advancements in nanomaterials for biomedical implants. BIOMEDICAL ENGINEERING ADVANCES 2022. [DOI: 10.1016/j.bea.2022.100029] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022] Open
|
11
|
Orassi V, Fischer H, Duda GN, Heiland M, Checa S, Rendenbach C. In Silico Biomechanical Evaluation of WE43 Magnesium Plates for Mandibular Fracture Fixation. Front Bioeng Biotechnol 2022; 9:803103. [PMID: 35223813 PMCID: PMC8866862 DOI: 10.3389/fbioe.2021.803103] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2021] [Accepted: 12/29/2021] [Indexed: 11/18/2022] Open
Abstract
Titanium fixation devices are the gold standard for the treatment of mandibular fractures; however, they present serious limitations, such as non-degradability and generation of imaging artifacts. As an alternative, biodegradable magnesium alloys have lately drawn attention due to their biodegradability and biocompatibility. In addition, magnesium alloys offer a relatively high modulus of elasticity in comparison to biodegradable polymers, being a potential option to substitute titanium in highly loaded anatomical areas, such as the mandible. This study aimed to evaluate the biomechanical competence of magnesium alloy WE43 plates for mandibular fracture fixation in comparison to the clinical standard or even softer polymer solutions. A 3D finite element model of the human mandible was developed, and four different fracture scenarios were simulated, together with physiological post-operative loading and boundary conditions. In a systematic comparison, the material properties of titanium alloy Ti-6Al-4V, magnesium alloy WE43, and polylactic acid (PLA) were assigned to the fixation devices, and two different plate thicknesses were tested. No failure was predicted in the fixation devices for any of the tested materials. Moreover, the magnesium and titanium fixation devices induced a similar amount of strain within the healing regions. On the other hand, the PLA devices led to higher mechanical strains within the healing region. Plate thickness only slightly influenced the primary fixation stability. Therefore, magnesium alloy WE43 fixation devices seem to provide a suitable biomechanical environment to support mandibular fracture healing in the early stages of bone healing. Magnesium WE43 showed a biomechanical performance similar to clinically used titanium devices with the added advantages of biodegradability and radiopacity, and at the same time it showed a remarkably higher primary stability compared to PLA fixation devices, which appear to be too unstable, especially in the posterior and more loaded mandibular fracture cases.
Collapse
Affiliation(s)
- Vincenzo Orassi
- Berlin Institute of Health at Charité—Universitätsmedizin Berlin, Julius Wolff Institute, Berlin, Germany
- Berlin-Brandenburg School for Regenerative Therapies, Berlin, Germany
| | - Heilwig Fischer
- Department of Oral and Maxillofacial Surgery, Charité—Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin and Berlin Institute of Health, Berlin, Germany
| | - Georg N. Duda
- Berlin Institute of Health at Charité—Universitätsmedizin Berlin, Julius Wolff Institute, Berlin, Germany
| | - Max Heiland
- Department of Oral and Maxillofacial Surgery, Charité—Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin and Berlin Institute of Health, Berlin, Germany
| | - Sara Checa
- Berlin Institute of Health at Charité—Universitätsmedizin Berlin, Julius Wolff Institute, Berlin, Germany
- *Correspondence: Sara Checa,
| | - Carsten Rendenbach
- Department of Oral and Maxillofacial Surgery, Charité—Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin and Berlin Institute of Health, Berlin, Germany
| |
Collapse
|
12
|
Magnesium-Based Alloys Used in Orthopedic Surgery. MATERIALS 2022; 15:ma15031148. [PMID: 35161092 PMCID: PMC8840615 DOI: 10.3390/ma15031148] [Citation(s) in RCA: 34] [Impact Index Per Article: 17.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/18/2021] [Revised: 01/27/2022] [Accepted: 01/29/2022] [Indexed: 02/04/2023]
Abstract
Magnesium (Mg)-based alloys have become an important category of materials that is attracting more and more attention due to their high potential use as orthopedic temporary implants. These alloys are a viable alternative to nondegradable metals implants in orthopedics. In this paper, a detailed overview covering alloy development and manufacturing techniques is described. Further, important attributes for Mg-based alloys involved in orthopedic implants fabrication, physiological and toxicological effects of each alloying element, mechanical properties, osteogenesis, and angiogenesis of Mg are presented. A section detailing the main biocompatible Mg-based alloys, with examples of mechanical properties, degradation behavior, and cytotoxicity tests related to in vitro experiments, is also provided. Special attention is given to animal testing, and the clinical translation is also reviewed, focusing on the main clinical cases that were conducted under human use approval.
Collapse
|
13
|
Sun Y, Helmholz H, Will O, Damm T, Wiese B, Luczak M, Peschke E, Luthringer-Feyerabend B, Ebel T, Hövener JB, Glüer C, Willumeit-Römer R. Dynamic in vivo monitoring of fracture healing process in response to magnesium implant with multimodal imaging: Pilot longitudinal study in a rat external fixation model. Biomater Sci 2022; 10:1532-1543. [DOI: 10.1039/d2bm00051b] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Rodent models are commonly used in pre-clinical research of magnesium (Mg) -based and other types of biomaterials for fracture treatment. Most studies selected unstable fixation methods, and there is a...
Collapse
|
14
|
Rendenbach C, Fischer H, Kopp A, Schmidt-Bleek K, Kreiker H, Stumpp S, Thiele M, Duda G, Hanken H, Beck-Broichsitter B, Jung O, Kröger N, Smeets R, Heiland M. Improved in vivo osseointegration and degradation behavior of PEO surface-modified WE43 magnesium plates and screws after 6 and 12 months. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2021; 129:112380. [PMID: 34579899 DOI: 10.1016/j.msec.2021.112380] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/06/2021] [Revised: 07/30/2021] [Accepted: 08/15/2021] [Indexed: 11/26/2022]
Abstract
Magnesium is a highly promising candidate with respect to its future use as a material for resorbable implants. When magnesium degrades, hydrogen gas is released. High doses of gas emergence are reported to impair osseointegration and may therefore lead to fixation failure. The successful delay and reduction of the degradation rate by applying plasma electrolytic oxidation (PEO) as a post processing surface modification method for magnesium alloy has recently been demonstrated. The aim of this study was thus to compare the degradation behavior of a WE43-based plate system with and without respective PEO surface modification and to further investigate osseointegration, as well as the resulting effects on the surrounding bony tissue of both variants in a miniature pig model. WE43 magnesium screws and plates without (WE43) and with PEO surface modification (WE43-PEO) were implanted in long bones of Göttingen Miniature Pigs. At six and twelve months after surgery, micro-CT and histomorphometric analysis was performed. Residual screw volume (SV/TV; WE43: 28.8 ± 21.1%; WE43-PEO: 62.9 ± 31.0%; p = 0.027) and bone implant contact area (BIC; WE43: 18.1 ± 21.7%; WE43-PEO: 51.6 ± 27.7%; p = 0.015) were increased after six months among the PEO-modified implants. Also, surrounding bone density within the cortical bone was not affected by surface modification (BVTV; WE43: 76.7 ± 13.1%; WE43-PEO: 73.1 ± 16.2%; p = 0.732). Intramedullar (BV/TV; WE43: 33.2 ± 16.7%; WE43-PEO 18.4 ± 9.0%; p = 0.047) and subperiosteal (bone area; WE43: 2.6 ± 3.4 mm2; WE43-PEO: 6,9 ± 5.2 mm2; p = 0.049) new bone formation was found for both, surface-modified and non-surface-modified groups. After twelve months, no significant differences of SV/TV and BV/TV were found between the two groups. PEO surface modification of WE43 plate systems improved osseointegration and significantly reduced the degradation rate within the first six months in vivo. Osteoconductive and osteogenic stimulation by WE43 magnesium implants led to overall increased bone growth, when prior PEO surface modification was conducted.
Collapse
Affiliation(s)
- Carsten Rendenbach
- Department of Oral and Maxillofacial Surgery, Charité - Universitätsmedizin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin and Berlin Institute of Health, Augustenburger Platz 1, 13353, Berlin, Germany.
| | - Heilwig Fischer
- Department of Oral and Maxillofacial Surgery, Charité - Universitätsmedizin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin and Berlin Institute of Health, Augustenburger Platz 1, 13353, Berlin, Germany; Julius Wolff Institute and Center for Musculoskeletal Surgery, Charité - Universitätsmedizin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin and Berlin Institute of Health, Augustenburger Platz 1, 13353, Berlin, Germany
| | | | - Katharina Schmidt-Bleek
- Julius Wolff Institute and Center for Musculoskeletal Surgery, Charité - Universitätsmedizin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin and Berlin Institute of Health, Augustenburger Platz 1, 13353, Berlin, Germany
| | - Henri Kreiker
- Department of Oral and Maxillofacial Surgery, Charité - Universitätsmedizin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin and Berlin Institute of Health, Augustenburger Platz 1, 13353, Berlin, Germany
| | - Sabine Stumpp
- Julius Wolff Institute and Center for Musculoskeletal Surgery, Charité - Universitätsmedizin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin and Berlin Institute of Health, Augustenburger Platz 1, 13353, Berlin, Germany
| | - Mario Thiele
- Julius Wolff Institute and Center for Musculoskeletal Surgery, Charité - Universitätsmedizin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin and Berlin Institute of Health, Augustenburger Platz 1, 13353, Berlin, Germany
| | - Georg Duda
- Julius Wolff Institute and Center for Musculoskeletal Surgery, Charité - Universitätsmedizin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin and Berlin Institute of Health, Augustenburger Platz 1, 13353, Berlin, Germany
| | - Henning Hanken
- Department of Oral and Maxillofacial Surgery, Asklepios Hospital North, Faculty of Medicine, Semmelweis University Campus Hamburg, Langenhorner Chaussee 560, 22419 Hamburg, Germany
| | - Benedicta Beck-Broichsitter
- Department of Oral and Maxillofacial Surgery, Charité - Universitätsmedizin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin and Berlin Institute of Health, Augustenburger Platz 1, 13353, Berlin, Germany
| | - Ole Jung
- Clinic and Policlinic for Dermatology and Venereology, University Medical Center Rostock, Schillingallee 35, 18057 Rostock, Germany
| | - Nadja Kröger
- Department of Plastic, Reconstructive and Aesthetic Surgery, University Hospital of Cologne, Kerpener Str. 62, 50 937 Köln, Germany
| | - Ralf Smeets
- Department of Oral and Maxillofacial Surgery, University Medical Center Hamburg-Eppendorf, Martinistraße 52, 20246, Hamburg, Germany
| | - Max Heiland
- Department of Oral and Maxillofacial Surgery, Charité - Universitätsmedizin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin and Berlin Institute of Health, Augustenburger Platz 1, 13353, Berlin, Germany
| |
Collapse
|
15
|
Pou-Álvarez P, Riveiro A, Nóvoa XR, Jin X, Del Val J, Comesaña R, Boutinguiza M, Lusquiños F, Jones JR, Pérez-Prado MT, Pou J. Laser-Guided Corrosion Control: A New Approach to Tailor the Degradation of Mg-Alloys. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2021; 17:e2100924. [PMID: 33760359 DOI: 10.1002/smll.202100924] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/15/2021] [Indexed: 06/12/2023]
Abstract
Despite corrosion being commonly seen as a problem to be avoided, applications such as batteries or biodegradable implants do benefit from corrosion-like phenomena. However, current strategies address corrosion control from a global perspective for a whole component, without considering local adaptations to functionality specifications or inhomogeneous environments. Here, a novel concept is presented: the local control and guidance of corrosion through a laser surface treatment. Immersion tests in saline solution of AZ31 magnesium alloy samples show degradation rates reduced up to 15 times with the treatment, owing to a fast passivation after the induced microstructural modifications. By controlling the treatment conditions, the degradation can be restricted to delimited regions and driven towards specific directions. The applicability of the method for the design of tailored degradation biomedical implants is demonstrated and uses for cathodic protection systems and batteries can also be anticipated.
Collapse
Affiliation(s)
- Pablo Pou-Álvarez
- Applied Physics Department, University of Vigo, E.E.I., Lagoas-Marcosende, Vigo, 36310, Spain
- Department of Materials, Imperial College London, South Kensington Campus, London, SW7 2AZ, UK
| | - Antonio Riveiro
- Materials Engineering, Applied Mechanics and Construction Department, University of Vigo, E.E.I., Lagoas-Marcosende, Vigo, 36310, Spain
| | - Xosé Ramón Nóvoa
- ENCOMAT group, University of Vigo, E.E.I., Lagoas-Marcosende, Vigo, 36310, Spain
| | - Xueze Jin
- IMDEA Materials Institute, C/Eric Kandel, 2, Getafe, Madrid, 28906, Spain
| | - Jesús Del Val
- Applied Physics Department, University of Vigo, E.E.I., Lagoas-Marcosende, Vigo, 36310, Spain
| | - Rafael Comesaña
- Materials Engineering, Applied Mechanics and Construction Department, University of Vigo, E.E.I., Lagoas-Marcosende, Vigo, 36310, Spain
| | - Mohamed Boutinguiza
- Applied Physics Department, University of Vigo, E.E.I., Lagoas-Marcosende, Vigo, 36310, Spain
- Galicia Sur Health Research Institute (IIS Galicia Sur) SERGAS-UVIGO, Estrada de Clara Campoamor, 341, Vigo, 36312, Spain
| | - Fernando Lusquiños
- Applied Physics Department, University of Vigo, E.E.I., Lagoas-Marcosende, Vigo, 36310, Spain
- Galicia Sur Health Research Institute (IIS Galicia Sur) SERGAS-UVIGO, Estrada de Clara Campoamor, 341, Vigo, 36312, Spain
| | - Julian R Jones
- Department of Materials, Imperial College London, South Kensington Campus, London, SW7 2AZ, UK
| | | | - Juan Pou
- Applied Physics Department, University of Vigo, E.E.I., Lagoas-Marcosende, Vigo, 36310, Spain
- Galicia Sur Health Research Institute (IIS Galicia Sur) SERGAS-UVIGO, Estrada de Clara Campoamor, 341, Vigo, 36312, Spain
| |
Collapse
|
16
|
Research status of biodegradable metals designed for oral and maxillofacial applications: A review. Bioact Mater 2021; 6:4186-4208. [PMID: 33997502 PMCID: PMC8099919 DOI: 10.1016/j.bioactmat.2021.01.011] [Citation(s) in RCA: 33] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2020] [Revised: 01/10/2021] [Accepted: 01/10/2021] [Indexed: 01/08/2023] Open
Abstract
The oral and maxillofacial regions have complex anatomical structures and different tissue types, which have vital health and aesthetic functions. Biodegradable metals (BMs) is a promising bioactive materials to treat oral and maxillofacial diseases. This review summarizes the research status and future research directions of BMs for oral and maxillofacial applications. Mg-based BMs and Zn-based BMs for bone fracture fixation systems, and guided bone regeneration (GBR) membranes, are discussed in detail. Zn-based BMs with a moderate degradation rate and superior mechanical properties for GBR membranes show great potential for clinical translation. Fe-based BMs have a relatively low degradation rate and insoluble degradation products, which greatly limit their application and clinical translation. Furthermore, we proposed potential future research directions for BMs in the oral and maxillofacial regions, including 3D printed BM bone scaffolds, surface modification for BMs GBR membranes, and BMs containing hydrogels for cartilage regeneration, soft tissue regeneration, and nerve regeneration. Taken together, the progress made in the development of BMs in oral and maxillofacial regions has laid a foundation for further clinical translation.
Collapse
|
17
|
Odashima K, Shimizu Y, Sano Y, Yamamoto A, Mukai T, Takada Y, Yanagisawa Y, Imai Y, Takahashi T, Kumamoto H. Osteogenic response under the periosteum by magnesium implantation in rat tibia. Dent Mater J 2021; 40:498-507. [PMID: 33642444 DOI: 10.4012/dmj.2020-011] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
This study was designed to examine osteoconductive effects of Mg in rats tibia. The animals were sacrificed after 1, 2, and 8 weeks. The elemental analysis was performed using SEM/EDX at week 1. Following X-ray micrography at weeks 2 and 8, samples were embedded in paraffin. The expression of osteocalcin was observed by immunohistochemical staining. The element concentrations of fibrous capsules around the specimens were also measured by ICP-MS. The concentrations of Ca and P on the surface of the Mg specimen increased in SEM/EDX. The tissue specimen showed new bone formation on the bone surface near the implanted area. The concentrations of Mg, Ca, and P were high in the fibrous capsules surrounding Mg. Implantation induced differentiation of osteoblasts, and this process was considered to be associated with new bone formation. Induction of cell differentiation may be influenced by corrosion products in addition to corroding magnesium.
Collapse
Affiliation(s)
- Kenji Odashima
- Division of Oral and Maxillofacial Surgery, Department of Oral and Medicine and Surgery, Graduate School of Dentistry, Tohoku University
| | - Yoshinaka Shimizu
- Division of Oral Pathology, Department of Oral Medicine and Surgery, Graduate School of Dentistry, Tohoku University
| | - Yuya Sano
- Division of Oral Pathology, Department of Oral Medicine and Surgery, Graduate School of Dentistry, Tohoku University
| | - Akiko Yamamoto
- Biometals Group, Biomaterials Unit, Nano-life Field, International Center for Materials Nanoarchitectonics, National Institute for Materials Science
| | - Toshiji Mukai
- Department of Mechanical Engineering, Kobe University
| | - Yukyo Takada
- Division of Dental Biomaterials, Tohoku University Graduate School of Dentistry, Tohoku University
| | - Yuta Yanagisawa
- Division of Oral and Maxillofacial Surgery, Department of Oral and Medicine and Surgery, Graduate School of Dentistry, Tohoku University
| | - Yoshimichi Imai
- Department of Plastic and Reconstructive Surgery, Tohoku University Graduate School of Medicine
| | - Tetsu Takahashi
- Division of Oral and Maxillofacial Surgery, Department of Oral and Medicine and Surgery, Graduate School of Dentistry, Tohoku University
| | - Hiroyuki Kumamoto
- Division of Oral Pathology, Department of Oral Medicine and Surgery, Graduate School of Dentistry, Tohoku University
| |
Collapse
|
18
|
Change in Pull-Out Force during Resorption of Magnesium Compression Screws for Osteosynthesis of Mandibular Condylar Fractures. MATERIALS 2021; 14:ma14020237. [PMID: 33418924 PMCID: PMC7825024 DOI: 10.3390/ma14020237] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/26/2020] [Revised: 12/31/2020] [Accepted: 01/04/2021] [Indexed: 12/14/2022]
Abstract
BACKGROUND Magnesium has been used as degradable fixation material for osteosynthesis, but it seems that mechanical strength is still a current issue in these fixations. The aim of this study was to evaluate the axial pull-out force of compression headless screws made of magnesium alloy during their resorption. METHODS The tests included screws made for osteosynthesis of the mandible head: 2.2 mm diameter magnesium alloy MgYREZr (42 screws) and 2.5 mm diameter polylactic-co-glycolic acid (PLGA) (42 pieces, control). The screws were resorbed in Sørensen's buffer for 2, 4, 8, 12, and 16 weeks, and force was measured as the screw was pulled out from the polyurethane block. RESULTS The force needed to pull the screw out was significantly higher for MgYREZr screws than for PLGA ones (p < 0.01). Within eight weeks, the pull-out force for MgYREZr significantly decreased to one third of its initial value (p < 0.01). The dynamics of this decrease were greater than those of the pull-out force for PLGA screws (p < 0.05). After these eight weeks, the values for metal and polymer screws equalized. It seems that the described reduction of force requires taking into account when using magnesium screws. This will provide more stable resorbable metallic osteosynthesis.
Collapse
|
19
|
Sukotjo C, Lima-Neto TJ, Santiago Júnior JF, Faverani LP, Miloro M. Is There a Role for Absorbable Metals in Surgery? A Systematic Review and Meta-Analysis of Mg/Mg Alloy Based Implants. MATERIALS 2020; 13:ma13183914. [PMID: 32899725 PMCID: PMC7558106 DOI: 10.3390/ma13183914] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/21/2020] [Revised: 08/31/2020] [Accepted: 09/01/2020] [Indexed: 12/19/2022]
Abstract
Magnesium (Mg) alloys have received attention in the literature as potential biomaterials for use as absorbable implants in oral and maxillofacial and orthopedic surgery applications. This study aimed to evaluate the available clinical studies related to patients who underwent bone fixation (patients), and received conventional fixation (intervention), in comparison to absorbable metals (comparison), in terms of follow-up and complications (outcomes). A systematic review and meta-analysis were performed in accordance with the PRISMA statement and PROSPERO (CRD42020188654), PICO question, ROBINS-I, and ROB scales. The relative risk (RR) of complications and failures were calculated considering a confidence interval (CI) of 95%. Eight studies (three randomized clinical trial (RCT), one retrospective studies, two case-control studies, and two prospective studies) involving 468 patients, including 230 Mg screws and 213 Titanium (Ti) screws, were analyzed. The meta-analysis did not show any significant differences when comparing the use of Mg and Ti screws for complications (p = 0.868). The estimated complication rate was 13.3% (95% CI: 8.3% to 20.6%) for the comparison group who received an absorbable Mg screw. The use of absorbable metals is feasible for clinical applications in bone surgery with equivalent outcomes to standard metal fixation devices.
Collapse
Affiliation(s)
- Cortino Sukotjo
- Department of Restorative Dentistry, College of Dentistry, University of Illinois at Chicago, Chicago, IL 60612, USA
- Correspondence: ; Tel.: +1-617-272-5512
| | - Tiburtino J. Lima-Neto
- Oral and Maxillofacial Surgery, Department of Diagnosis and Surgery, Division of Oral and Maxillofacial Surgery, School of Dentistry, São Paulo State University—Unesp, Araçatuba, São Paulo 16015-050, Brazil;
| | - Joel Fereira Santiago Júnior
- Department of Health Sciences, Centro Universitário Sagrado Coração-UNISAGRADO, Bauru, São Paulo 16011-160, Brazil;
| | - Leonardo P. Faverani
- Department of Diagnosis and Surgery, Division of Oral and Maxillofacial Surgery and Implantology, School of Dentistry, São Paulo State University—Unesp, Araçatuba, São Paulo 16015-050, Brazil;
| | - Michael Miloro
- Department of Oral and Maxillofacial Surgery, College of Dentistry, University of Illinois at Chicago, Chicago, IL 60612, USA;
| |
Collapse
|
20
|
On SW, Cho SW, Byun SH, Yang BE. Bioabsorbable Osteofixation Materials for Maxillofacial Bone Surgery: A Review on Polymers and Magnesium-Based Materials. Biomedicines 2020; 8:biomedicines8090300. [PMID: 32825692 PMCID: PMC7555479 DOI: 10.3390/biomedicines8090300] [Citation(s) in RCA: 29] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2020] [Revised: 08/17/2020] [Accepted: 08/19/2020] [Indexed: 01/24/2023] Open
Abstract
Clinical application of osteofixation materials is essential in performing maxillofacial surgeries requiring rigid fixation of bone such as trauma surgery, orthognathic surgery, and skeletal reconstruction. In addition to the use of titanium plates and screws, clinical applications and attempts using bioabsorbable materials for osteofixation surgery are increasing with demands to avoid secondary surgery for the removal of plates and screws. Synthetic polymeric plates and screws were developed, reaching satisfactory physical properties comparable to those made with titanium. Although these polymeric materials are actively used in clinical practice, there remain some limitations to be improved. Due to questionable physical strength and cumbersome molding procedures, interests in resorbable metal materials for osteofixation emerged. Magnesium (Mg) gained attention again in the last decade as a new metallic alternative, and numerous animal studies to evaluate the possibility of clinical application of Mg-based materials are being conducted. Thanks to these researches and studies, vascular application of Mg-based biomaterials was successful; however, further studies are required for the clinical application of Mg-based biomaterials for osteofixation, especially in the facial skeleton. The review provides an overview of bioabsorbable osteofixation materials in maxillofacial bone surgery from polymer to Mg.
Collapse
Affiliation(s)
- Sung-Woon On
- Division of Oral and Maxillofacial Surgery, Department of Dentistry, Hallym University Dongtan Sacred Heart Hospital, Hwaseong 18450, Korea;
- Graduated School of Clinical Dentistry, Hallym University, Chuncheon 24252, Korea; (S.-W.C.); (S.-H.B.)
- Institute of Clinical Dentistry, Hallym University, Chuncheon 24252, Korea
| | - Seoung-Won Cho
- Graduated School of Clinical Dentistry, Hallym University, Chuncheon 24252, Korea; (S.-W.C.); (S.-H.B.)
- Institute of Clinical Dentistry, Hallym University, Chuncheon 24252, Korea
- Division of Oral and Maxillofacial Surgery, Hallym University Sacred Heart Hospital, Anyang 14066, Korea
| | - Soo-Hwan Byun
- Graduated School of Clinical Dentistry, Hallym University, Chuncheon 24252, Korea; (S.-W.C.); (S.-H.B.)
- Institute of Clinical Dentistry, Hallym University, Chuncheon 24252, Korea
- Division of Oral and Maxillofacial Surgery, Hallym University Sacred Heart Hospital, Anyang 14066, Korea
| | - Byoung-Eun Yang
- Graduated School of Clinical Dentistry, Hallym University, Chuncheon 24252, Korea; (S.-W.C.); (S.-H.B.)
- Institute of Clinical Dentistry, Hallym University, Chuncheon 24252, Korea
- Division of Oral and Maxillofacial Surgery, Hallym University Sacred Heart Hospital, Anyang 14066, Korea
- Correspondence: ; Tel.: +82-380-3870
| |
Collapse
|
21
|
|
22
|
Pre-clinical testing of human size magnesium implants in miniature pigs: Implant degradation and bone fracture healing at multiple implantation sites. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2020; 108:110389. [DOI: 10.1016/j.msec.2019.110389] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/17/2019] [Revised: 10/02/2019] [Accepted: 10/31/2019] [Indexed: 11/23/2022]
|
23
|
Tang X, Zhang X, Chen Y, Zhang W, Qian J, Soliman H, Qu A, Liu Q, Pu S, Huang N, Wan G. Ultraviolet irradiation assisted liquid phase deposited titanium dioxide (TiO2)-incorporated into phytic acid coating on magnesium for slowing-down biodegradation and improving osteo-compatibility. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2020; 108:110487. [DOI: 10.1016/j.msec.2019.110487] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/25/2019] [Revised: 11/05/2019] [Accepted: 11/23/2019] [Indexed: 12/20/2022]
|
24
|
Wang WH, Wang F, Zhao HF, Yan K, Huang CL, Yin Y, Huang Q, Chen ZZ, Zhu WY. Injectable Magnesium-Zinc Alloy Containing Hydrogel Complex for Bone Regeneration. Front Bioeng Biotechnol 2020; 8:617585. [PMID: 33324628 PMCID: PMC7726114 DOI: 10.3389/fbioe.2020.617585] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2020] [Accepted: 11/02/2020] [Indexed: 12/18/2022] Open
Abstract
Gelatin methacryloyl (GelMA) has been widely used in bone engineering. It can also be filled into the calvarial defects with irregular shape. However, lack of osteoinductive capacity limits its potential as a candidate repair material for calvarial defects. In this study, we developed an injectable magnesium-zinc alloy containing hydrogel complex (Mg-IHC), in which the alloy was fabricated in an atomization process and had small sphere, regular shape, and good fluidity. Mg-IHC can be injected and plastically shaped. After cross-linking, it contents the elastic modulus similar to GelMA, and has inner holes suitable for nutrient transportation. Furthermore, Mg-IHC showed promising biocompatibility according to our evaluations of its cell adhesion, growth status, and proliferating activity. The results of alkaline phosphatase (ALP) activity, ALP staining, alizarin red staining, and real-time polymerase chain reaction (PCR) further indicated that Mg-IHC could significantly promote the osteogenic differentiation of MC3T3-E1 cells and upregulate the genetic expression of collagen I (COL-I), osteocalcin (OCN), and runt-related transcription factor 2 (RUNX2). Finally, after applied to a mouse model of critical-sized calvarial defect, Mg-IHC remarkably enhanced bone formation at the defect site. All of these results suggest that Mg-IHC can promote bone regeneration and can be potentially considered as a candidate for calvarial defect repairing.
Collapse
Affiliation(s)
- Wei-Hua Wang
- Department of Neurosurgery, The Affiliated Suzhou Science and Technology Town Hospital, Nanjing Medical University, Suzhou, China
- Institute of Clinical Medicine Research, The Affiliated Suzhou Science and Technology Town Hospital, Nanjing Medical University, Suzhou, China
| | - Fei Wang
- Institute of Biomaterials and Medical Devices, Southeast University, Suzhou, China
| | - Hai-Feng Zhao
- Department of Pathology, The Affiliated Suzhou Science and Technology Town Hospital, Nanjing Medical University, Suzhou, China
| | - Ke Yan
- Department of Neurosurgery, The Affiliated Suzhou Science and Technology Town Hospital, Nanjing Medical University, Suzhou, China
| | - Cui-Ling Huang
- Department of Neurology, The Second People’s Hospital of Longgang District, Shenzhen, China
| | - Yin Yin
- Laboratory Animal Center, Soochow University, Suzhou, China
| | - Qiang Huang
- Department of Neurosurgery, The Second Affiliated Hospital, Soochow University, Suzhou, China
| | - Zao-Zao Chen
- Institute of Biomaterials and Medical Devices, Southeast University, Suzhou, China
- School of Biological Science and Medical Engineering, Southeast University, Nanjing, China
- *Correspondence: Zao-Zao Chen,
| | - Wen-Yu Zhu
- Department of Neurosurgery, The Affiliated Suzhou Science and Technology Town Hospital, Nanjing Medical University, Suzhou, China
- Institute of Clinical Medicine Research, The Affiliated Suzhou Science and Technology Town Hospital, Nanjing Medical University, Suzhou, China
- Wen-Yu Zhu,
| |
Collapse
|
25
|
Soderlind J, Cihova M, Schäublin R, Risbud S, Löffler JF. Towards refining microstructures of biodegradable magnesium alloy WE43 by spark plasma sintering. Acta Biomater 2019; 98:67-80. [PMID: 31254685 DOI: 10.1016/j.actbio.2019.06.045] [Citation(s) in RCA: 25] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2018] [Revised: 06/19/2019] [Accepted: 06/24/2019] [Indexed: 11/29/2022]
Abstract
Microstructural refinement of magnesium (Mg) alloys is beneficial for mechanical and corrosion properties, both of which are critical for their successful application as temporary implant materials. One method of achieving a refined microstructure is through rapid solidification via gas-atomization-powder production. In this study we investigated spark plasma sintering (SPS) as a potential processing method for maintaining this refined microstructure while achieving a range of porosities up to full densification. We characterized the microstructural evolution as a function of sintering temperature from 250 to 450 °C for the alloy WE43 using multi-scale correlative microscopy techniques, including light microscopy and scanning and transmission electron microscopy-based methods. The spatial distribution of the two major alloying elements, neodymium (Nd) and yttrium (Y), was determined and the intermetallic phases they form identified using energy dispersive X-ray spectroscopy in conjunction with electron diffraction. The gas-atomized powder microstructure consists of Mg-rich dendrites and a percolating interdendritic Mg-Nd-Y ternary phase with structure Mg14Nd2Y, surrounded by a high Nd and Y content in solid solution. This microstructure is maintained up to a sintering temperature of 350 °C, while with higher sintering temperatures segregation of Nd and Y dominates. The percolating ternary phase breaks up into faceted globular precipitates with structure Mg5Nd, which is isomorphous to Mg14Nd2Y. Y comes out of solution and migrates to previous powder-particle surfaces, possibly forming Y2O3. Sample densities ranged from 64 to 100% for sintering temperatures of 250 to 450 °C, respectively, and the grain size remained constant at about 10 µm. SPS is demonstrated to be an attractive alternative method for processing Mg alloys to a wide range of porosities and fine microstructures. The microstructural refinement achieved by SPS holds the potential for slow and homogeneous corrosion. STATEMENT OF SIGNIFICANCE: This study presents the impact spark plasma sintering (SPS) has on the microstructure of WE43, a magnesium alloy used for biodegradable implants. SPS is of great interest in this context as it is scalable, rapid, and has the potential for tuning density while maintaining a refined microstructure. The microstructure and density are explored from the gas-atomized powder to the densified material using electron microscopy and chemical mapping from the macro- to the nano-level. The insights gained reveal an original evolution of rare-earth element distribution with an isomorphous chemistry change, while the microstructure develops from the non-equilibrium state (powder) towards an equilibrium structure upon sintering. This study, including measurements of mechanical performance, sets the premises of SPS for the fabrication of Mg-based implants with tunable characteristics.
Collapse
Affiliation(s)
- Julie Soderlind
- Department of Materials Science and Engineering, University of California, Davis, CA 95616, United States; Lawrence Livermore National Laboratory, Livermore, CA 94550, United States; Laboratory of Metal Physics and Technology, Department of Materials, ETH Zurich, 8093 Zurich, Switzerland
| | - Martina Cihova
- Laboratory of Metal Physics and Technology, Department of Materials, ETH Zurich, 8093 Zurich, Switzerland
| | - Robin Schäublin
- Laboratory of Metal Physics and Technology, Department of Materials, ETH Zurich, 8093 Zurich, Switzerland
| | - Subhash Risbud
- Department of Materials Science and Engineering, University of California, Davis, CA 95616, United States
| | - Jörg F Löffler
- Laboratory of Metal Physics and Technology, Department of Materials, ETH Zurich, 8093 Zurich, Switzerland.
| |
Collapse
|
26
|
Naujokat H, Ruff CB, Klüter T, Seitz JM, Açil Y, Wiltfang J. Influence of surface modifications on the degradation of standard-sized magnesium plates and healing of mandibular osteotomies in miniature pigs. Int J Oral Maxillofac Surg 2019; 49:272-283. [PMID: 31227276 DOI: 10.1016/j.ijom.2019.03.966] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2018] [Revised: 01/16/2019] [Accepted: 03/17/2019] [Indexed: 11/28/2022]
Abstract
Biodegradable magnesium alloys are suitable osteosynthesis materials. Despite the alloy composition, surface modifications appear to have an influence on the degradation process and biocompatibility. The aim of this study was to investigate the impact of hydrogenation and fluoridation of the surface in a mandibular osteotomy model. Standard-sized plates and screws were implanted in an osteotomy at the mandibular angle in nine miniature pigs. The plates and screws were harvested together with the adjacent tissues at 8 weeks after surgery and were investigated by micro-computed tomography and histological analysis. The bone healing of the osteotomy was undisturbed, independent of the surface properties. The adjacent bone tissue showed new bone formation at the implant surface; however, formation of some lacunae could be observed. The corrosion was between 9.8% and 11.6% (fluoridated<hydrogenated<non-modified) in histological specimens, while radiologically neither the volume nor the density of the osteosynthesis material was reduced in any treatment group. The soft tissues exhibited full biocompatibility with every surface property. In summary, surface modification by hydrogenation and fluoridation did not significantly influence bone healing, biocompatibility, or corrosion kinetics of the magnesium osteosynthesis at the mandibular angle.
Collapse
Affiliation(s)
- H Naujokat
- Department of Oral and Maxillofacial Surgery, University Hospital of Schleswig-Holstein, Kiel, Germany.
| | - C B Ruff
- Department of Oral and Maxillofacial Surgery, University Hospital of Schleswig-Holstein, Kiel, Germany
| | - T Klüter
- Department of Trauma Surgery, University Hospital of Schleswig-Holstein, Kiel, Germany
| | | | - Y Açil
- Department of Oral and Maxillofacial Surgery, University Hospital of Schleswig-Holstein, Kiel, Germany
| | - J Wiltfang
- Department of Oral and Maxillofacial Surgery, University Hospital of Schleswig-Holstein, Kiel, Germany
| |
Collapse
|
27
|
Investigation of zinc‑copper alloys as potential materials for craniomaxillofacial osteosynthesis implants. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2019; 103:109826. [PMID: 31349503 DOI: 10.1016/j.msec.2019.109826] [Citation(s) in RCA: 42] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/07/2019] [Revised: 05/17/2019] [Accepted: 05/28/2019] [Indexed: 12/22/2022]
Abstract
In this study, zinc‑copper (ZnCu) alloys were investigated regarding their feasibility as absorbable metals for osteosynthesis implants, especially in the craniomaxillofacial area. Mechanical properties and in vitro corrosion behavior of as-rolled Zn-xCu (x = 1, 2 and 4 wt%) alloys were systematically evaluated and screened. The as-rolled Zn4Cu alloy had mechanical properties that were superior to the most absorbable craniomaxillofacial osteosynthesis materials recently reported. The addition of Cu to Zn showed to have no apparent effect on the corrosion rates of the samples. The rolling process on Zn and Zn1Cu resulted in more uniform corrosion than on as-cast counterparts after 28 days immersion. Furthermore, the Zn4Cu alloys exhibited no apparent cytotoxic effect towards L929, TAg or Saos-2 cells. Proliferation rates of TAg and Saos-2 cells were shown to be activated by specific Zn ion concentrations in the as-rolled Zn4Cu alloy extracts. Analysis of in vitro antibacterial properties revealed that the as-rolled Zn4Cu alloy possessed the potential to inhibit biofilm formation of mixed oral bacteria. We conclude that the as-rolled Zn4Cu alloy might be a promising material for fabrication of craniomaxillofacial osteosynthesis implants.
Collapse
|
28
|
Rendenbach C, Schoellchen M, Bueschel J, Gauer T, Sedlacik J, Kutzner D, Vallittu PK, Heiland M, Smeets R, Fiehler J, Siemonsen S. Evaluation and reduction of magnetic resonance imaging artefacts induced by distinct plates for osseous fixation: an in vitro study @ 3 T. Dentomaxillofac Radiol 2018; 47:20170361. [PMID: 29718688 DOI: 10.1259/dmfr.20170361] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022] Open
Abstract
OBJECTIVES: To analyze MRI artefacts induced at 3 T by bioresorbable, titanium (TI) and glass fibre reinforced composite (GFRC) plates for osseous reconstruction. METHODS: Fixation plates including bioresorbable polymers (Inion CPS, Inion Oy, Tampere, Finland; Rapidsorb, DePuy Synthes, Umkirch, Germany; Resorb X, Gebrueder KLS Martin GmbH, Tuttlingen, Germany), GFRC (Skulle Implants Oy, Turku, Finland) and TI plates of varying thickness and design (DePuy Synthes, Umkirch, Germany) were embedded in agarose gel and a 3 T MRI was performed using a standard protocol for head and neck imaging including T1W and T2W sequences. Additionally, different artefact reduction techniques (slice encoding for metal artefact reduction & ultrashort echo time) were used and their impact on the extent of artefacts evaluated for each material. RESULTS: All TI plates induced significantly more artefacts than resorbable plates in T1W and T2W sequences. GFRCs induced the least artefacts in both sequences. The total extent of artefacts increased with plate thickness and height. Plate thickness had no influence on the percentage of overestimation in all three dimensions. TI-induced artefacts were significantly reduced by both artefact reduction techniques. CONCLUSIONS: Polylactide, GFRC and magnesium plates produce less susceptibility artefacts in MRI compared to TI, while the dimensions of TI plates directly influence artefact extension. Slice encoding for metal artefact reduction and ultrashort echo time significantly reduce metal artefacts at the expense of scan time or image resolution.
Collapse
Affiliation(s)
- Carsten Rendenbach
- 1 Department of Oral and Maxillofacial Surgery, Charité - Universitaetsmedizin Berlin, Corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health , Berlin , Germany.,2 Berlin Institute of Health (BIH) , Berlin , Germany
| | - Max Schoellchen
- 3 Department of Oral and Maxillofacial Surgery, University Medical Center Hamburg-Eppendorf , Hamburg , Germany
| | - Julie Bueschel
- 3 Department of Oral and Maxillofacial Surgery, University Medical Center Hamburg-Eppendorf , Hamburg , Germany
| | - Tobias Gauer
- 4 Department of Radiotherapy and Radiation Oncology, University Medical Center Hamburg-Eppendorf , Hamburg , Germany
| | - Jan Sedlacik
- 5 Department of Diagnostic and Interventional Neuroradiology, University Medical Center Hamburg-Eppendorf , Hamburg , Germany
| | - Daniel Kutzner
- 5 Department of Diagnostic and Interventional Neuroradiology, University Medical Center Hamburg-Eppendorf , Hamburg , Germany
| | - Pekka K Vallittu
- 6 Department of Biomaterials Science, Institute of Dentistry, University of Turku, and City of Turku, Welfare Division , Turku , Finland
| | - Max Heiland
- 1 Department of Oral and Maxillofacial Surgery, Charité - Universitaetsmedizin Berlin, Corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health , Berlin , Germany
| | - Ralf Smeets
- 3 Department of Oral and Maxillofacial Surgery, University Medical Center Hamburg-Eppendorf , Hamburg , Germany
| | - Jens Fiehler
- 5 Department of Diagnostic and Interventional Neuroradiology, University Medical Center Hamburg-Eppendorf , Hamburg , Germany
| | - Susanne Siemonsen
- 5 Department of Diagnostic and Interventional Neuroradiology, University Medical Center Hamburg-Eppendorf , Hamburg , Germany
| |
Collapse
|
29
|
Jewell CM. A game of thrones and broken bones. Sci Transl Med 2017. [DOI: 10.1126/scitranslmed.aao6885] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/02/2022]
Abstract
Repair of cranial bone trauma with degradable magnesium implants could reduce complications and eliminate the need for implant removal.
Collapse
Affiliation(s)
- Christopher M. Jewell
- Fischell Department of Bioengineering, University of Maryland, College Park, MD 20742, USA
| |
Collapse
|