1
|
Ferraro S, Bussetti M, Rizzardi S, Braga F, Panteghini M. Verification of Harmonization of Serum Total and Free Prostate-Specific Antigen (PSA) Measurements and Implications for Medical Decisions. Clin Chem 2021; 67:543-553. [PMID: 33674839 DOI: 10.1093/clinchem/hvaa268] [Citation(s) in RCA: 31] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2020] [Accepted: 10/08/2020] [Indexed: 01/16/2023]
Abstract
BACKGROUND Previous studies have shown that the harmonization of prostate-specific antigen (PSA) assays remained limited even after the introduction of WHO International Standards. This information needs updating for current measuring systems (MS) and reevaluation according to established analytical performance specifications (APS) and the characteristics of antibodies used. METHODS Total (tPSA) and free (fPSA) PSA were measured in 135 and 137 native serum samples, respectively, by Abbott Alinity i, Beckman Access Dxl, Roche Cobas e801, and Siemens Atellica IM MSs. Passing-Bablok regression and difference plots were used to compare results from each MS to the all-method median values. Agreement among methods was evaluated against APS for bias derived from biological variation of the 2 measurands. RESULTS The median interassay CV for tPSA MSs (11.5%; 25-75th percentiles, 9.2-13.4) fulfilled the minimum APS goal for intermethod bias (15.9%), while the interassay CV for fPSA did not [20.4% (25-75th percentiles, 18.4-22.7) vs goal 17.6%]. Considering the all-method median value of each sample as reference, all tPSA MSs exhibited a mean percentage bias within the minimum goal. On the other hand, Alinity (+21.3%) and Access (-24.2%) were out of the minimum bias goal for fPSA, the disagreement explained only in minimal part by the heterogeneity of employed antibodies. CONCLUSIONS The harmonization among tPSA MSs is acceptable only when minimum APS are applied and necessitates further improvement. The marked disagreement among fPSA MSs questions the use of fPSA as a second-level test for biopsy referral.
Collapse
Affiliation(s)
- Simona Ferraro
- Unità Operativa Complessa di Patologia Clinica, ASST Fatebenefratelli-Sacco, Milano, Italy
| | - Marco Bussetti
- Unità Operativa Complessa di Patologia Clinica, ASST Fatebenefratelli-Sacco, Milano, Italy
| | - Sara Rizzardi
- Unità Operativa Laboratorio Analisi Chimico Cliniche e Microbiologiche, ASST Cremona, Cremona, Italy
| | - Federica Braga
- Unità Operativa Complessa di Patologia Clinica, ASST Fatebenefratelli-Sacco, Milano, Italy.,Research Centre for Metrological Traceability in Laboratory Medicine (CIRME), University of Milan, Milan, Italy
| | - Mauro Panteghini
- Unità Operativa Complessa di Patologia Clinica, ASST Fatebenefratelli-Sacco, Milano, Italy.,Research Centre for Metrological Traceability in Laboratory Medicine (CIRME), University of Milan, Milan, Italy
| |
Collapse
|
2
|
Ferraro S, Bussetti M, Rossi RS, Incarbone GP, Panteghini M. Is pre-biopsy serum prostate specific antigen retesting always justified? A study of the influence of individual and analytical factors on decision making for biopsy referral. Clin Chim Acta 2021; 516:77-82. [PMID: 33524337 DOI: 10.1016/j.cca.2021.01.017] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2020] [Revised: 01/08/2021] [Accepted: 01/22/2021] [Indexed: 10/22/2022]
Abstract
BACKGROUND AND AIMS We investigated factors influencing pre-biopsy prostate-specific antigen (PSA) retesting as recommended by clinical guidelines. MATERIALS AND METHODS 333 patients screened for prostate cancer (PCa) repeated PSA (Roche Cobas systems) after a median of 3.9 months, before performing biopsy. Multiple regression models were used to assess effects of patients' characteristics on PSA results and changes over time. RESULTS PCa [n = 132 (40.7%)] and cancer-free [n = 192 (59.3%)] patients had similar rate of PSA positive results at baseline (84.8% vs. 83.9%, P = 0.931). Their rate of reversion to normal PSA after retesting was negligible (0.9% in PCa and 3.7% in PCa-free patients, P = 0.286). 31.1% of PCa and 31.3% of cancer-free patients (P = 0.426) showed a significant PSA increase after retesting. Age was a confounder since not only PSA increased in older PCa patients, but it was also related to PCa histological grade, in turn associated to PSA increase. In PCa-free patients, glandular inflammation, present in 1/3 of subjects, was also associated to higher PSA concentrations. CONCLUSION When obtained with the same immunoassay under controlled analytical conditions, a PSA positive result is confirmed after retesting in the great majority of screened patients. Neither analytical factors nor intraindividual variability appeared to justify PSA retesting before biopsy referral.
Collapse
Affiliation(s)
- Simona Ferraro
- Unità Operativa di Patologia Clinica, ASST Fatebenefratelli-Sacco, Milano, Italy.
| | - Marco Bussetti
- Unità Operativa di Patologia Clinica, ASST Fatebenefratelli-Sacco, Milano, Italy
| | - Roberta Simona Rossi
- Unità Operativa di Anatomia Patologica, ASST Fatebenefratelli-Sacco, Milano, Italy
| | | | - Mauro Panteghini
- Unità Operativa di Patologia Clinica, ASST Fatebenefratelli-Sacco, Milano, Italy
| |
Collapse
|
3
|
Serdarevic N, Dabla P, Stanciu AE. Systematic Differences Between Total and Free Prostate-Specific Antigen Immunoassays: Comparison Using Passing and Bablok Regression. Indian J Clin Biochem 2019; 36:151-158. [PMID: 33867705 DOI: 10.1007/s12291-019-0818-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2018] [Accepted: 01/28/2019] [Indexed: 12/01/2022]
Abstract
Recent studies have shown that there are systematic differences among total and free prostate-specificantigen (PSA) immunoassays. In this study we analyzedintermethod differences in total PSA (tPSA) and free PSA(fPSA) measurement using ARCHITECT i2000SR (Abbott Diagnostics) and COBAS E601 (Roche Diagnostics). A number of 160 blood samples were tested for tPSA and 50 samples for fPSA (selecting only sampleswith tPSA: 4.1-10.0 μg/L). Passing-Bablok regression analysis was used to compare the two analytical methods fortPSA, fPSA and percentage of fPSA (%fPSA). A strong correlation was noticed between ARCHITECT i2000SR and COBAS E601 for tPSA, fPSA and %fPSA (r between 0.94 and 0.99). Concentrations of tPSA and fPSA measured by COBAS E601 were higher thanthose measured by ARCHITECT i2000SR with a bias of 0.8 μg/L for tPSA and 0.14 μg/L for fPSA. Analyzing therelative difference between methods for fPSA and %fPSA, COBAS E601 exceed a 10% relative difference limit. Our study confirms that there are differences in measured concentrations of tPSA and fPSA byvarious commercial methods. Because clinical judgment on subsequent diagnostic procedures, such as prostatebiopsy, is based on tPSA and fPSA results, tests harmonization should be a priority.
Collapse
Affiliation(s)
- Nafija Serdarevic
- Institute for Clinical Chemistry and Biochemistry, University of Sarajevo Clinics Center, 71000 Sarajevo, Bosnia and Herzegovina
| | - Pradeep Dabla
- Department of Biochemistry, G.B.Pant Institute of Postgraduate Medical Education and Research (GIPMER), GNCTD, Delhi, India
| | - Adina Elena Stanciu
- Department of Carcinogenesis and Molecular Biology, Institute of Oncology Bucharest, 252 Fundeni, 022338 Bucharest, Romania
| |
Collapse
|
4
|
Stephan C, Bangma C, Vignati G, Bartsch G, Lein M, Jung K, Philippe M, Semjonow A, Catalona WJ. 20–25% Lower Concentrations of Total and Free Prostate-Specific Antigen (PSA) after Calibration of PSA Assays to the WHO Reference Materials – Analysis of 1098 Patients in Four Centers. Int J Biol Markers 2018. [DOI: 10.1177/172460080902400201] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Aim To examine the potential clinical implications of the recalibration of total prostate-specific antigen (PSA) and free PSA (fPSA) assays to the World Health Organization (WHO) standard materials. Material and methods Data from 1098 patients with or without clinically detected prostate cancer (PCa) from four independent cohort studies were compared using commercial assays calibrated to the traditional Hybritech® PSA (PSA-Hyb) and fPSA (fPSA-Hyb) standards and to the WHO 96/670 (PSA-WHO) and 96/668 (fPSA-WHO) standards. The Access® Immunoassay System (Beckman Coulter, Inc.) was used in all studies. Results All studies showed 20% to 25% lower PSA and fPSA test results with the WHO-standardized assays. No significant change in %fPSA (fPSA/PSA × 100) was observed. Continuing to use the traditional clinical PSA cutoffs obtained with the Hybritech standard after changing to the PSA-WHO standard could result in up to one-third of prostate cancer cases being missed. Conclusions: Manufacturers should fully inform laboratories about a calibration change and its clinical impact. Laboratory reports for PSA measurements should indicate the assay's manufacturer and which calibration standard was used to avoid misleading information concerning PCa risk
Collapse
Affiliation(s)
- Carsten Stephan
- Department of Urology, Charité - Universitätsmedizin Berlin, Berlin - Germany
| | - Chris Bangma
- Department of Urology, Erasmus Medical Center and University, Rotterdam - The Netherlands
| | - Giulio Vignati
- Center of Endocrine and Metabolic Diseases, G. Fornaroli Hospital, Magenta - Italy
| | - Georg Bartsch
- Department of Urology, Medical University Innsbruck, Innsbruck - Austria
| | - Michael Lein
- Department of Urology, Charité - Universitätsmedizin Berlin, Berlin - Germany
- Berlin Institute for Urologic Research, Berlin - Germany
| | - Klaus Jung
- Department of Urology, Charité - Universitätsmedizin Berlin, Berlin - Germany
- Berlin Institute for Urologic Research, Berlin - Germany
| | - Marianne Philippe
- Department of Clinical Biochemistry, Cliniques Universitaires Saint-Luc, Brussels - Belgium
| | - Axel Semjonow
- Prostate Center, University Clinic Münster - Germany
| | - William J. Catalona
- Department of Urology, Northwestern Feinberg School of Medicine, Chicago, IL - USA
| |
Collapse
|
5
|
Sturgeon CM. Common decision limits — The need for harmonised immunoassays. Clin Chim Acta 2014; 432:122-6. [DOI: 10.1016/j.cca.2013.11.023] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2013] [Revised: 11/12/2013] [Accepted: 11/19/2013] [Indexed: 11/15/2022]
|
6
|
Vucetic Z, Dnistrian A, Nilsson O, Lilja HG, Plebani M. Suitability of quality control materials for prostate-specific antigen (PSA) measurement: inter-method variability of common tumor marker control materials. Clin Chem Lab Med 2013; 51:873-80. [PMID: 23314549 DOI: 10.1515/cclm-2012-0660] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2012] [Accepted: 12/05/2012] [Indexed: 11/15/2022]
Abstract
BACKGROUND Quality control materials with minimal inter-assay differences and clinically relevant proportions of different molecular forms of the analyte are needed to optimize intra- and inter-laboratory accuracy and precision. METHODS We assessed if clinically relevant total prostate-specific antigen (tPSA) levels were present in seven commercially available Multi Constituent Tumor Marker Controls (MC-TMC). Further, we determined the concentration of free PSA (fPSA) and calculated the percentage of free PSA (%fPSA) in all materials. Finally, we determined variability of TMC materials across several commonly used PSA platforms. RESULTS All MC-TMC materials contained at least one concentration of tPSA in normal and pathologic range. Control materials varied in the amount of fPSA and %fPSA, with most controls consisting of fPSA only and only one MC-TMC containing medically relevant levels of around 35% fPSA. Only a minority of MC-TMC materials showed minimal variability across four PSA methods while the majority of PSA controls showed wide inter-method differences. CONCLUSIONS Use of many commercially available controls for PSA could lead to biased PSA measurements because they contain medically irrelevant proportions of fPSA and show significant variation among different PSA assay platforms.
Collapse
|
7
|
Sturgeon CM, Viljoen A. Analytical error and interference in immunoassay: minimizing risk. Ann Clin Biochem 2011; 48:418-32. [DOI: 10.1258/acb.2011.011073] [Citation(s) in RCA: 137] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
8
|
Relationship of spermatoscopy, prostatic acid phosphatase activity and prostate-specific antigen (p30) assays with further DNA typing in forensic samples from rape cases. Forensic Sci Int 2011; 206:111-8. [PMID: 20692115 DOI: 10.1016/j.forsciint.2010.07.012] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2009] [Revised: 06/28/2010] [Accepted: 07/07/2010] [Indexed: 10/19/2022]
|
9
|
Zhao N, He Y, Mao X, Sun Y, Zhang X, Li CZ, Lin Y, Liu G. Electrochemical assay of active prostate-specific antigen (PSA) using ferrocene-functionalized peptide probes. Electrochem commun 2010. [DOI: 10.1016/j.elecom.2010.01.022] [Citation(s) in RCA: 74] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022] Open
|
10
|
Durner J. Die klinische Chemie - Herausforderung der Medizin für die analytische Chemie und die Nanowissenschaften. Angew Chem Int Ed Engl 2009. [DOI: 10.1002/ange.200903363] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
|
11
|
Durner J. Clinical Chemistry: Challenges for Analytical Chemistry and the Nanosciences from Medicine. Angew Chem Int Ed Engl 2009; 49:1026-51. [DOI: 10.1002/anie.200903363] [Citation(s) in RCA: 68] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
|
12
|
Morris H. Traceability and standardization of immunoassays: A major challenge. Clin Biochem 2009; 42:241-5. [DOI: 10.1016/j.clinbiochem.2008.09.005] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2008] [Accepted: 09/11/2008] [Indexed: 10/21/2022]
|
13
|
Stephan C, Köpke T, Semjonow A, Lein M, Deger S, Schrader M, Miller K, Jung K. Discordant total and free prostate-specific antigen (PSA) assays: does calibration with WHO reference materials diminish the problem? Clin Chem Lab Med 2009; 47:1325-31. [DOI: 10.1515/cclm.2009.285] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
|
14
|
Sturgeon CM, Duffy MJ, Stenman UH, Lilja H, Brünner N, Chan DW, Babaian R, Bast RC, Dowell B, Esteva FJ, Haglund C, Harbeck N, Hayes DF, Holten-Andersen M, Klee GG, Lamerz R, Looijenga LH, Molina R, Nielsen HJ, Rittenhouse H, Semjonow A, Shih IM, Sibley P, Sölétormos G, Stephan C, Sokoll L, Hoffman BR, Diamandis EP. National Academy of Clinical Biochemistry Laboratory Medicine Practice Guidelines for Use of Tumor Markers in Testicular, Prostate, Colorectal, Breast, and Ovarian Cancers. Clin Chem 2008; 54:e11-79. [DOI: 10.1373/clinchem.2008.105601] [Citation(s) in RCA: 458] [Impact Index Per Article: 28.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
Abstract
Background: Updated National Academy of Clinical Biochemistry (NACB) Laboratory Medicine Practice Guidelines for the use of tumor markers in the clinic have been developed.
Methods: Published reports relevant to use of tumor markers for 5 cancer sites—testicular, prostate, colorectal, breast, and ovarian—were critically reviewed.
Results: For testicular cancer, α-fetoprotein, human chorionic gonadotropin, and lactate dehydrogenase are recommended for diagnosis/case finding, staging, prognosis determination, recurrence detection, and therapy monitoring. α-Fetoprotein is also recommended for differential diagnosis of nonseminomatous and seminomatous germ cell tumors. Prostate-specific antigen (PSA) is not recommended for prostate cancer screening, but may be used for detecting disease recurrence and monitoring therapy. Free PSA measurement data are useful for distinguishing malignant from benign prostatic disease when total PSA is <10 μg/L. In colorectal cancer, carcinoembryonic antigen is recommended (with some caveats) for prognosis determination, postoperative surveillance, and therapy monitoring in advanced disease. Fecal occult blood testing may be used for screening asymptomatic adults 50 years or older. For breast cancer, estrogen and progesterone receptors are mandatory for predicting response to hormone therapy, human epidermal growth factor receptor-2 measurement is mandatory for predicting response to trastuzumab, and urokinase plasminogen activator/plasminogen activator inhibitor 1 may be used for determining prognosis in lymph node–negative patients. CA15-3/BR27–29 or carcinoembryonic antigen may be used for therapy monitoring in advanced disease. CA125 is recommended (with transvaginal ultrasound) for early detection of ovarian cancer in women at high risk for this disease. CA125 is also recommended for differential diagnosis of suspicious pelvic masses in postmenopausal women, as well as for detection of recurrence, monitoring of therapy, and determination of prognosis in women with ovarian cancer.
Conclusions: Implementation of these recommendations should encourage optimal use of tumor markers.
Collapse
Affiliation(s)
- Catharine M Sturgeon
- Department of Clinical Biochemistry, Royal Infirmary of Edinburgh, Edinburgh, UK
| | - Michael J Duffy
- Department of Pathology and Laboratory Medicine, St Vincent’s University Hospital and UCD School of Medicine and Medical Science, Conway Institute of Biomolecular and Biomedical Research, University College Dublin, Dublin, Ireland
| | - Ulf-Håkan Stenman
- Department of Clinical Chemistry, Helsinki University Central Hospital, Helsinki, Finland
| | - Hans Lilja
- Departments of Clinical Laboratories, Urology, and Medicine, Memorial Sloan-Kettering Cancer Center, New York, NY
| | - Nils Brünner
- Section of Biomedicine, Department of Veterinary Pathobiology, Faculty of Life Sciences, University of Copenhagen, Denmark
| | - Daniel W Chan
- Departments of Pathology and Oncology, Johns Hopkins Medical Institutions, Baltimore, MD
| | - Richard Babaian
- Department of Urology, The University of Texas Anderson Cancer Center, Houston, TX
| | - Robert C Bast
- Department of Experimental Therapeutics, University of Texas Anderson Cancer Center, Houston, Texas, USA
| | | | - Francisco J Esteva
- Departments of Breast Medical Oncology, Molecular and Cellular Oncology, University of Texas M.D. Anderson Cancer Center, Houston TX
| | - Caj Haglund
- Department of Surgery, Helsinki University Central Hospital, Helsinki, Finland
| | - Nadia Harbeck
- Frauenklinik der Technischen Universität München, Klinikum rechts der Isar, Munich, Germany
| | - Daniel F Hayes
- Breast Oncology Program, University of Michigan Comprehensive Cancer Center, Ann Arbor, MI
| | - Mads Holten-Andersen
- Section of Biomedicine, Department of Veterinary Pathobiology, Faculty of Life Sciences, University of Copenhagen, Denmark
| | - George G Klee
- Department of Laboratory Medicine and Pathology, Mayo Clinic College of Medicine, Rochester, MN
| | - Rolf Lamerz
- Department of Medicine, Klinikum of the University of Munich, Grosshadern, Germany
| | - Leendert H Looijenga
- Laboratory of Experimental Patho-Oncology, Erasmus MC-University Medical Center Rotterdam, and Daniel den Hoed Cancer Center, Rotterdam, the Netherlands
| | - Rafael Molina
- Laboratory of Biochemistry, Hospital Clinico Provincial, Barcelona, Spain
| | - Hans Jørgen Nielsen
- Department of Surgical Gastroenterology, Hvidovre Hospital, Copenhagen, Denmark
| | | | - Axel Semjonow
- Prostate Center, Department of Urology, University Clinic Muenster, Muenster, Germany
| | - Ie-Ming Shih
- Departments of Pathology and Oncology, Johns Hopkins Medical Institutions, Baltimore, MD
| | - Paul Sibley
- Siemens Medical Solutions Diagnostics, Glyn Rhonwy, Llanberis, Gwynedd, UK
| | | | - Carsten Stephan
- Department of Urology, Charité Hospital, Universitätsmedizin Berlin, Berlin, Germany
| | - Lori Sokoll
- Departments of Pathology and Oncology, Johns Hopkins Medical Institutions, Baltimore, MD
| | - Barry R Hoffman
- Department of Pathology and Laboratory Medicine, Mount Sinai Hospital, and Department of Laboratory Medicine and Pathobiology, University of Toronto, Ontario, Canada
| | - Eleftherios P Diamandis
- Department of Pathology and Laboratory Medicine, Mount Sinai Hospital, and Department of Laboratory Medicine and Pathobiology, University of Toronto, Ontario, Canada
| | | |
Collapse
|
15
|
Stephan C, Kahrs AM, Klotzek S, Reiche J, Müller C, Lein M, Deger S, Miller K, Jung K. Toward metrological traceability in the determination of prostate-specific antigen (PSA): calibrating Beckman Coulter Hybritech Access PSA assays to WHO standards compared with the traditional Hybritech standards. Clin Chem Lab Med 2008; 46:623-9. [PMID: 18839463 DOI: 10.1515/cclm.2008.129] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND The metrological traceability of prostate-specific antigen (PSA) assay calibration to WHO standards is desirable to potentially improve the comparability between PSA assays. A method comparison was performed between the traditionally standardized Beckman Coulter Hybritech Access PSA and free PSA (fPSA) assays and a new alternate calibration of assays aligned to the WHO standards 96/670 and 96/668, respectively. METHODS Sera from 641 men with and without prostate cancer, various control materials and mixtures of different proportions of the WHO standards were measured with both assay calibrations. RESULTS Excellent comparability between the corresponding assay calibrations was observed, with correlation coefficients of at least 0.996. The Passing-Bablok slopes were 0.747 for total PSA (tPSA), 0.776 for fPSA and 1.02 for the percentage ratio of fPSA to tPSA (%fPSA), while the corresponding percentages of the new WHO-aligned assay results related to the traditional assays were 76.2%, 77% and 102.2%. Receiver operating characteristics revealed no differences between the two PSA assay calibrations. CONCLUSIONS The WHO calibration yields results approximately 25% lower for tPSA and fPSA values when compared with the conventional Hybritech calibration. Using the WHO-aligned PSA assay, a tPSA cut-off of 3 microg/L should be considered in clinical practice, while %fPSA cut-offs could be retained.
Collapse
Affiliation(s)
- Carsten Stephan
- Department of Urology, Charité - Universitätsmedizin Berlin, Berlin, Germany
| | | | | | | | | | | | | | | | | |
Collapse
|
16
|
Raorane DA, Lim MD, Chen FF, Craik CS, Majumdar A. Quantitative and label-free technique for measuring protease activity and inhibition using a microfluidic cantilever array. NANO LETTERS 2008; 8:2968-74. [PMID: 18720973 PMCID: PMC2663003 DOI: 10.1021/nl8019455] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/11/2023]
Abstract
We report the use of a SiN x based gold coated microcantilever array to quantitatively measure the activity and inhibition of a model protease immobilized on its surface. Trypsin was covalently bound to the gold surface of the microcantilever using a synthetic spacer, and the remaining exposed silicon nitride surface was passivated with silanated polyethylene glycol. The nanoscale cantilever motions induced by trypsin during substrate turnover were quantitatively measured using an optical laser-deflection technique. These microcantilever deflections directly correlated with the degree of protease turnover of excess synthetic fibronectin substrate ( K M = 0.58 x 10 (-6) M). Inhibition of surface-immobilized trypsin by soybean trypsin inhibitor (SBTI) was also observed using this system.
Collapse
Affiliation(s)
- Digvijay A Raorane
- Department of Mechanical Engineering, University of California, Berkeley, California 94720, USA
| | | | | | | | | |
Collapse
|