1
|
Panagopoulos A, Giannika V. A comprehensive assessment of the economic and technical viability of a zero liquid discharge (ZLD) hybrid desalination system for water and salt recovery. JOURNAL OF ENVIRONMENTAL MANAGEMENT 2024; 359:121057. [PMID: 38718606 DOI: 10.1016/j.jenvman.2024.121057] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/30/2023] [Revised: 04/06/2024] [Accepted: 04/29/2024] [Indexed: 05/22/2024]
Abstract
Brine, a by-product of desalination and industrial facilities, is becoming more and more of an environmental issue. This comprehensive techno-economic assessment (TEA), focusing on the technical and economic aspects, investigates the performance and viability of a novel hybrid desalination brine treatment system known as zero liquid discharge (ZLD). Notably, this research represents the first instance of evaluating the feasibility and effectiveness of integrating three distinct desalination processes, namely brine concentrator (BC), high-pressure reverse osmosis (HPRO), and membrane-promoted crystallization (MPC), within a ZLD framework. The findings of this study demonstrate an exceptional water recovery rate of 97.04%, while the energy requirements stand at a reasonable level of 17.53 kWh/m3. Financially, the ZLD system proves to be at least 3.28 times more cost-effective than conventional evaporation ponds and offers comparable cost efficiency to alternatives such as land application and deep-well injection. Moreover, the ZLD system exhibits profitability potential by marketing both drinking water and solid salt or solely desalinated water. The daily profit from the sale of generated water varies from US$194.08 to US$281.41, with Greece and Cyprus attaining the lowest and highest profit, respectively. When considering the sale of both salt and water, the profit rises by 8% across all locations.
Collapse
Affiliation(s)
- Argyris Panagopoulos
- School of Chemical Engineering, National Technical University of Athens, 9 Iroon Polytechniou St., Zografou 15780 Athens, Greece.
| | - Vasiliki Giannika
- School of Chemical Engineering, National Technical University of Athens, 9 Iroon Polytechniou St., Zografou 15780 Athens, Greece.
| |
Collapse
|
2
|
Guo W, Li C, Zhao J, Ding Y, Yang Q, Guan H. The treatment of petrochemical wastewater via ozone-persulfate coupled catalytic oxidation: mechanism of removal of soluble organic matter. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2024; 31:29400-29414. [PMID: 38570434 DOI: 10.1007/s11356-024-32998-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/06/2023] [Accepted: 03/15/2024] [Indexed: 04/05/2024]
Abstract
Petrochemical wastewater contains a variety of organic pollutants. Advanced oxidation processes (AOPs) are used for deep petrochemical wastewater treatment with distinct advantages, including the complete mineralization of organic substances, minimal residual byproducts, and compatibility with biological treatment systems. This work evaluates the effectiveness of three methods, namely, ozone, persulfate, and O3-PMS (ozone-persulfate) processes, which were compared to remove soluble organic matter. The O3-PMS process offered significant advantages in terms of organic matter removal efficiency. This process involves ozone dissolution in an aqueous persulfate solution, producing a more significant amount of hydroxyl radicals in comparison to single AOPs. The production of hydroxyl radicals and the synergistic effect of hydroxyl radicals and persulfate radicals were investigated. In the O3-PMS process, transition metal ions were added to understand the mechanism of the O3-PMS coupled catalytic oxidation system. The results showed that when the ozone concentration was in the range of 5 ~ 25 mg/L, the dosage of persulfate was in the range of 0.01 ~ 0.05 mol/L, the dosage of metal compounds was in the range of 0:0 ~ 2:1, and the reaction time was in the range of 0 ~ 2 h; the optimum chemical oxygen demand (CODCr) and total organic content (TOC) removal effect was achieved under the coupled system with an ozone concentration of 10 mg/L, a persulfate dosage of 0.02 mol/L, a 1:2 dosage ratio of between Fe2+ and Cu2+ compounds, and a reaction time of 2 h. Under optimal reaction conditions, the rates of CODCr and TOC removal reached 70% and 79.3%, respectively. Furthermore, the removal kinetics of the O3-PMS coupled catalytic oxidation system was analyzed to optimize the removal conditions of COD and TOC, and the mechanism regulating the degradation of dissolved organic matter was explored by three-dimensional fluorescence and GC-MS technology. Thus, O3-PMS coupled catalytic oxidation is an effective process for the deep treatment of wastewater. The careful selection of transition metal ions serves as a theoretical foundation for the subsequent preparation of catalysts for the ozone persulfate oxidation system, and this study provides a suitable reference for removing organic matter from petrochemical wastewater.
Collapse
Affiliation(s)
- Wenjing Guo
- School of Environmental and Municipal Engineering, Lanzhou Jiaotong University, Lanzhou, 730070, China
| | - Chong Li
- School of Environmental and Municipal Engineering, Lanzhou Jiaotong University, Lanzhou, 730070, China
| | - Junguang Zhao
- School of Environmental and Municipal Engineering, Lanzhou Jiaotong University, Lanzhou, 730070, China
| | - Yun Ding
- School of Environmental and Municipal Engineering, Lanzhou Jiaotong University, Lanzhou, 730070, China
| | - Qing Yang
- School of Environmental and Municipal Engineering, Lanzhou Jiaotong University, Lanzhou, 730070, China.
- Engineering Research Center for Comprehensive Utilization of Water Resources in Cold and Drought Areas, Ministry of Education, Lanzhou Jiaotong University, Lanzhou, China.
| | - Hongxun Guan
- Beijing Tianhao Kerun Environmental Technology Co, Beijing, 100176, China
| |
Collapse
|
3
|
Kou Y, Yang B, Jiang J, Sun H, Zhang R, Li Z, Wang Q, Shi Q, Chen C. Characteristics of dissolved organic matter in point-source wastewaters at a petrochemical plant: Molecular constituents and contributions to the influent of wastewater treatment plant. ENVIRONMENTAL RESEARCH 2023; 238:117157. [PMID: 37726030 DOI: 10.1016/j.envres.2023.117157] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/28/2023] [Revised: 08/29/2023] [Accepted: 09/14/2023] [Indexed: 09/21/2023]
Abstract
Dissolved organic matter (DOM) in point-source petrochemical wastewaters (PCWs) from different operating units is closely linked to the efficiency of wastewater treatment plant (WWTP). However, systematic studies on DOM characters of point-source PCWs and their influences on WWTP influents were seldom conducted. In this study, DOM in three low-salinity point-source PCWs and four high-salinity point-source PCWs at a typical petrochemical plant were comprehensively characterized at a molecular level. Orbitrap mass spectrometry results indicated that point-source PCWs had diverse DOM constituents tightly related to the corresponding petrochemical processes. Phenols in oily wastewaters (OW), phenols and N-containing compounds in coal partial oxidation wastewater (POXW), and naphthenic acids (NAs) and aromatic acids in crude oil electric desalting unit wastewater (EDW) were characteristic DOM constituents for low-salinity point-source PCWs. While S-containing compounds (mercaptans, thiophenes) and NAs in spent caustic liquors (SCL), alcohols and esters in butanol-octanol plant wastewater (BOW), high molecular weight aromatic ketones in phenol-acetone plant wastewater (PAW), and oxygenated NAs as well as short chain N-containing compounds in concentrate from reverse osmosis unit (ROC) were characteristic DOM constituents for high-salinity point-source PCWs. Spearman correlation analysis indicated that though with relative low pollutant contents (OW) and discharge volume (EDW), N/O/S-containing compounds of OW and EDW greatly contributed to the polar DOM constituents of low-salinity influent in WWTP (R > 0.5, P < 0.001). While N-containing compounds of ROC mainly contributed to the polar DOM of high-salinity influent (R > 0.5, P < 0.001). Though N-/S-containing species in PAW had low contents, they also posed obvious impacts on DOM constituents of high-salinity influent. Interestingly, some O-/S-containing species were newly formed during the confluent process of high-salinity point-source PCWs. The results strengthened the combined contributions of pollutants contents, discharge emission and DOM constituents of point-source PCWs to the water matrix of WWTP influents, which would provide reference for the management of PCW streams.
Collapse
Affiliation(s)
- Yue Kou
- State Key Laboratory of Heavy Oil Processing, China University of Petroleum-Beijing, Beijing, 102249, China.
| | - Baiyu Yang
- State Key Laboratory of Heavy Oil Processing, China University of Petroleum-Beijing, Beijing, 102249, China
| | - Juntao Jiang
- State Key Laboratory of Heavy Oil Processing, China University of Petroleum-Beijing, Beijing, 102249, China
| | - He Sun
- State Key Laboratory of Heavy Oil Processing, China University of Petroleum-Beijing, Beijing, 102249, China
| | - Rui Zhang
- State Key Laboratory of Heavy Oil Processing, China University of Petroleum-Beijing, Beijing, 102249, China
| | - Zhuoyu Li
- State Key Laboratory of Heavy Oil Processing, China University of Petroleum-Beijing, Beijing, 102249, China.
| | - Qinghong Wang
- State Key Laboratory of Heavy Oil Processing, China University of Petroleum-Beijing, Beijing, 102249, China
| | - Quan Shi
- State Key Laboratory of Heavy Oil Processing, China University of Petroleum-Beijing, Beijing, 102249, China
| | - Chunmao Chen
- State Key Laboratory of Heavy Oil Processing, China University of Petroleum-Beijing, Beijing, 102249, China
| |
Collapse
|
4
|
Shan LL, Tan Z, Chen Y, Wang RS, Zhang M, Pang CL, Cui YH, Liao ZM, Ma HQ, Zhu ZB. Biodegradability enhancement of waste lubricating oil regeneration wastewater using electrocoagulation pretreatment. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2023; 30:106421-106430. [PMID: 37728675 DOI: 10.1007/s11356-023-29841-7] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/18/2023] [Accepted: 09/07/2023] [Indexed: 09/21/2023]
Abstract
As a sustainable management of fossil fuel resources and ecological environment protection, recycling used lubricating oil has received widespread attention. However, large amounts of waste lubricating-oil regeneration wastewater (WLORW) are inevitably produced in the recycling process, and challenges are faced by traditional biological treatment of WLORW. Thus, this study investigated the effectiveness of electrocoagulation (EC) as pretreatment and its removal mechanism. The electrolysis parameters (current density, initial pH, and inter-electrode distance) were considered, and maximal 60.06% of oil removal was achieved at a current density of 15 mA/cm2, initial pH of 7, and an inter-electrode distance of 2 cm. The dispersed oil of WLORW was relatively easily removed, and most of the oil removal was contributed by emulsified oil within 5-10 μm. Gas chromatography-mass spectrometry (GC-MS) analysis revealed that effective removal of the biorefractory organic compounds could contribute to the improvement of biodegradability of WLORW. Thus, the 5-day biochemical oxygen demand/chemical oxygen demand ratio (BOD5/COD) was significantly enhanced by 4.31 times, which highly benefits future biological treatment. The routes of WLORW removal could be concluded as charge neutralization, adsorption bridging, sweep flocculation, and air flotation. The results demonstrate that EC has potential as an effective pretreatment technology for WLORW biological treatment.
Collapse
Affiliation(s)
- Li-Li Shan
- School of Civil Engineering and Architecture, East China Jiao Tong University, Nanchang, 330013, China
- Jiangxi JDL Environmental Protection Co., Ltd, Nanchang, 330199, China
- School of Environmental Science and Engineering, Huazhong University of Science and Technology, Wuhan, 430074, China
| | - Zhao Tan
- School of Civil Engineering and Architecture, East China Jiao Tong University, Nanchang, 330013, China
| | - Yu Chen
- School of Civil Engineering and Architecture, East China Jiao Tong University, Nanchang, 330013, China
| | - Ruo-Shan Wang
- School of Civil Engineering and Architecture, East China Jiao Tong University, Nanchang, 330013, China
| | - Meng Zhang
- Jiangxi Academy of Environmental Sciences, Nanchang, 330039, China
| | - Chang-Long Pang
- Jiangxi ZXDH Environmental Protection Industry Tecnology Institute Co., Ltd, Nanchang, 330000, China
| | - Yu-Hong Cui
- School of Environmental Science and Engineering, Huazhong University of Science and Technology, Wuhan, 430074, China
| | - Zhi-Min Liao
- Jiangxi JDL Environmental Protection Co., Ltd, Nanchang, 330199, China
| | - Hong-Qiang Ma
- School of Civil Engineering and Architecture, East China Jiao Tong University, Nanchang, 330013, China
| | - Ze-Bing Zhu
- School of Civil Engineering and Architecture, East China Jiao Tong University, Nanchang, 330013, China.
| |
Collapse
|
5
|
Kou Y, Jiang J, Yang B, Sun H, Wang L, Wang Q, El-Din MG, Shi Q, Chen C. Transformation of dissolved organic matter at a full-scale petrochemical wastewater treatment plant. JOURNAL OF ENVIRONMENTAL MANAGEMENT 2023; 329:117021. [PMID: 36542886 DOI: 10.1016/j.jenvman.2022.117021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/07/2022] [Revised: 12/06/2022] [Accepted: 12/11/2022] [Indexed: 06/17/2023]
Abstract
Transformation of dissolved organic matter (DOM) in petrochemical wastewater (PCW) treatment has rarely been studied. In this work, low- and high-salinity PCW were collected from a treatment plant and the transformations of DOM at molecular level along the treatment processes of both PCW were comparatively investigated. By using Orbitrap MS, the polar DOM constituents were categorized into five molecular classes namely saturated compounds, aliphatics, highly unsaturated and phenolic compounds (Huph), polyphenols and condensed polycyclic aromatics (Cpla). Aliphatics (58.62%) with low molecular weight (150-250 Da) and O/C (0-0.2) were dominant in raw low-salinity PCW; while Huph (65.03%) with O/C at 0.2-0.8 were rich in raw high-salinity PCW. After full-scale treatment, differentiated DOM constituents in both raw PCWs were transformed into aliphatics and Huph with O/C at 0.3-0.5. Anoxic/Oxic treatment of low-salinity system (L-A/O) removed a high fraction of aliphatics (53.05%); while Huph with low O/C (0.1-0.3) (65.68%) in the effluent of L-A/O were further mineralized by ozonation of low-salinity system (L-ozonation). In comparison, anoxic/oxic treatment of high-salinity system (H-A/O) mainly removed unsaturated Huph (34.10%) and aliphatics (30.86%). This resulted in a decrease of dissolved organic carbon as indicated via Spearman correlation. Different from L-ozonation, ozonation of high-salinity system (H-ozonation) degraded aliphatics (26.09%) and Huph (41.85%) with a relatively high O/C (0.2-1.2). After L-A/O and L-ozonation treatments, remaining saturated compounds that were originated from raw low-salinity PCW, were removed by subsequent biological aerated filter. Comparatively, after H-A/O and H-ozonation treatments, residual Huph and aliphatics which were mainly bio-derivates and ozonated intermediates, were further removed by air flotation filter. Hence, DOM transformation of different PCWs along similar treatments varied significantly. This study provides in-depth insights on DOM transformation along a full-scale PCW treatment process.
Collapse
Affiliation(s)
- Yue Kou
- State Key Laboratory of Heavy Oil Processing, Beijing Key Laboratory of Oil and Gas Pollution Control, China University of Petroleum-Beijing, Beijing, 102249, China
| | - Juntao Jiang
- State Key Laboratory of Heavy Oil Processing, Beijing Key Laboratory of Oil and Gas Pollution Control, China University of Petroleum-Beijing, Beijing, 102249, China
| | - Baiyu Yang
- State Key Laboratory of Heavy Oil Processing, Beijing Key Laboratory of Oil and Gas Pollution Control, China University of Petroleum-Beijing, Beijing, 102249, China
| | - He Sun
- State Key Laboratory of Heavy Oil Processing, Beijing Key Laboratory of Oil and Gas Pollution Control, China University of Petroleum-Beijing, Beijing, 102249, China
| | - Leqi Wang
- State Key Laboratory of Heavy Oil Processing, Beijing Key Laboratory of Oil and Gas Pollution Control, China University of Petroleum-Beijing, Beijing, 102249, China
| | - Qinghong Wang
- State Key Laboratory of Heavy Oil Processing, Beijing Key Laboratory of Oil and Gas Pollution Control, China University of Petroleum-Beijing, Beijing, 102249, China.
| | - Mohamed Gamal El-Din
- Department of Civil and Environmental Engineering, University of Alberta, Edmonton, Alberta, T6G 1H9, Canada.
| | - Quan Shi
- State Key Laboratory of Heavy Oil Processing, Beijing Key Laboratory of Oil and Gas Pollution Control, China University of Petroleum-Beijing, Beijing, 102249, China
| | - Chunmao Chen
- State Key Laboratory of Heavy Oil Processing, Beijing Key Laboratory of Oil and Gas Pollution Control, China University of Petroleum-Beijing, Beijing, 102249, China
| |
Collapse
|
6
|
Narayan Thorat B, Kumar Sonwani R. Current technologies and future perspectives for the treatment of complex petroleum refinery wastewater: A review. BIORESOURCE TECHNOLOGY 2022; 355:127263. [PMID: 35526717 DOI: 10.1016/j.biortech.2022.127263] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/19/2022] [Revised: 04/28/2022] [Accepted: 05/01/2022] [Indexed: 06/14/2023]
Abstract
Petroleum refinery wastewater (PRW) is a complex mixture of hydrocarbons, sulphides, ammonia, oils, suspended and dissolved solids, and heavy metals. As these pollutants are toxic and recalcitrant, it is essential to address the above issue with efficient, economical, and eco-friendly technologies. In this review, initially, an overview of the characteristics of wastewater discharged from different petroleum refinery units is discussed. Further, various pre-treatment and post-treatment strategies for complex PRW are introduced. A segregated approach has been proposed to treat the crude desalting, sour, spent caustic, and oily wastewater of petroleum refineries. The combined systems (e.g., ozonation + moving bed biofilm reactor and photocatalysis + packed bed biofilm reactor) for the treatment of low biodegradability index wastewater (BOD5/COD < 0.2) were discussed to construct a perspective map and implement the proposed system efficiently. The economic, toxicity, and biodegradability aspects are also introduced, along with research gaps and future scope.
Collapse
Affiliation(s)
- Bhaskar Narayan Thorat
- Department of Chemical Engineering, Institute of Chemical Technology, Mumbai-Indian Oil Odisha Campus, Bhubaneswar, Odisha 751013, India
| | - Ravi Kumar Sonwani
- Department of Chemical Engineering, Institute of Chemical Technology, Mumbai-Indian Oil Odisha Campus, Bhubaneswar, Odisha 751013, India; Department of Chemical Engineering, Indian Institute of Petroleum and Energy (IIPE), Visakhapatnam, Andhra Pradesh 530003, India.
| |
Collapse
|
7
|
Synergetic effects of mixing parameters, settling characteristics and process kinetics on coagulation treatment of tannery industry wastewater. CHEMICAL PAPERS 2022. [DOI: 10.1007/s11696-022-02156-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
|
8
|
Li Y, Wu B, He C, Nie F, Shi Q. Comprehensive chemical characterization of dissolved organic matter in typical point-source refinery wastewaters. CHEMOSPHERE 2022; 286:131617. [PMID: 34303906 DOI: 10.1016/j.chemosphere.2021.131617] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/30/2021] [Revised: 07/17/2021] [Accepted: 07/19/2021] [Indexed: 06/13/2023]
Abstract
In petroleum refineries, the electric desalting, distillation, and stripping processes could generate large amounts of wastewaters that contain toxic substances. In this study, eight wastewater samples were collected from the three typical refining processes for comprehensive chemical characterization of the dissolved organic matter (DOM) using excitation emission matrix fluorescence spectroscopy, gas chromatography-mass spectrometry, and Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS). Results showed that protein-like components and benzene were ubiquitous in all these wastewaters. Oxygen-containing volatile organic compounds had higher contents in crude distillation and stripping wastewater than those in electric desalting wastewater. Among the three refinery processes, molecular composition of DOM in the stripping wastewater had the highest complexity. The Ox and OxSy class species assigned from the negative-ion electrospray ionization FT-ICR MS were dominant in all wastewaters. The OxS2 class species which were effectively removed during stripping treatment had highest relative abundance in stripping influent. These results are instructive to guide the development of "divide and conquer" and would improve the treatment and management of refinery wastewater streams.
Collapse
Affiliation(s)
- Yuguo Li
- State Key Laboratory of Heavy Oil Processing, China University of Petroleum, Beijing, 102249, China; State Key Laboratory of Petroleum Pollution Control, CNPC Research Institute of Safety and Environmental Technology, Beijing, 102249, China.
| | - Baichun Wu
- State Key Laboratory of Heavy Oil Processing, China University of Petroleum, Beijing, 102249, China; State Key Laboratory of Petroleum Pollution Control, CNPC Research Institute of Safety and Environmental Technology, Beijing, 102249, China.
| | - Chen He
- State Key Laboratory of Heavy Oil Processing, China University of Petroleum, Beijing, 102249, China.
| | - Fan Nie
- State Key Laboratory of Petroleum Pollution Control, CNPC Research Institute of Safety and Environmental Technology, Beijing, 102249, China.
| | - Quan Shi
- State Key Laboratory of Heavy Oil Processing, China University of Petroleum, Beijing, 102249, China.
| |
Collapse
|
9
|
Rasouli Y, Parivazh MM, Abbasi M, Akrami M. The Effect of Ceramic Membranes' Structure on the Oil and Ions Removal in Pre-Treatment of the Desalter Unit Wastewater. MEMBRANES 2021; 12:membranes12010059. [PMID: 35054583 PMCID: PMC8779256 DOI: 10.3390/membranes12010059] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/18/2021] [Revised: 12/19/2021] [Accepted: 12/28/2021] [Indexed: 11/16/2022]
Abstract
Salts, organic materials, and hazardous materials can be found regularly in the effluent from a desalter unit of crude oil. These materials should be separated from the wastewater. Four kinds of inexpensive and innovative ceramic microfiltration membranes (mullite, mullite-alumina (MA 50%), mullite-alumina-zeolite (MAZ 20%), and mullite-zeolite (MZ 40%)) were synthesized in this research using locally available inexpensive raw materials such as kaolin clay, natural zeolite, and alpha-alumina powders. Analyses carried out on the membranes include XRD, SEM, void fraction, the average diameter of the pores, and the ability to withstand mechanical stress. Effluent from the desalter unit was synthesized in the laboratory using the salts most present in the desalter wastewater (NaCl, MgCl2, and CaCl2) and crude oil. This synthesized wastewater was treated with prepared ceramic membranes. It was discovered that different salt concentrations (0, 5000, 25,000, 50,000, 75,000, and 100,000 mg L−1) affected the permeate flux (PF), oil rejection, and ion rejection by the membrane. Results showed that in a lower concentration of salts (5000 and 25,000 mg L−1), PF of all types of ceramic membranes was increased significantly, while in the higher concentration, PF declined due to polarization concentration and high fouling effects. Oil and ion rejection was increased slightly by increasing salt dosage in wastewater due to higher ionic strength. Monovalent (Na+) and multivalent (Ca2+ and Mg2+) ion rejection was reported about 5 to 13%, and 23 to 40% respectively. Oil rejection varied from 96.2 to 99.2%.
Collapse
Affiliation(s)
- Yaser Rasouli
- Department of Civil, Geological & Mining Engineering, Ecole Polytechnique de Montreal, 2900 Boulevard Edouard-Montpetit, Montreal, QC H3T 1J4, Canada;
| | - Mohammad Mehdi Parivazh
- Department of Chemical Engineering, Amirkabir University of Technology (Tehran Polytechnic), Tehran P.O. Box 15875-4413, Iran;
| | - Mohsen Abbasi
- Department of Chemical Engineering, Faculty of Petroleum, Gas and Petrochemical Engineering, Persian Gulf University, Bushehr P.O. Box 75169-13798, Iran
- Correspondence: (M.A.); (M.A.)
| | - Mohammad Akrami
- Department of Engineering, University of Exeter, Exeter EX4 4QF, UK
- Correspondence: (M.A.); (M.A.)
| |
Collapse
|
10
|
Ye H, Yang B, Wang Q, How ZT, Nie C, Chelme-Ayala P, Guo S, Chen C, Gamal El-Din M. Influences of integrated coagulation-ozonation pretreatment on the characteristics of dissolved organic pollutants (DOPs) of heavy oil electric desalting wastewaters. JOURNAL OF ENVIRONMENTAL MANAGEMENT 2021; 300:113756. [PMID: 34534758 DOI: 10.1016/j.jenvman.2021.113756] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/29/2021] [Revised: 08/20/2021] [Accepted: 09/12/2021] [Indexed: 06/13/2023]
Abstract
The quality of heavy oil electric desalting wastewaters (HO-EDWs) affects the effectiveness of refinery wastewater treatment plants. In this study, an integrated coagulation-ozonation (ICO) process was used to pretreat HO-EDWs and the influences on the characteristics of dissolved organic pollutants (DOPs) were investigated. Coagulation using aluminum sulfate removed 39% of soluble chemical oxygen demand (SCOD), 21% of dissolved organic carbon (DOC), 57% of petroleum hydrocarbons and 38% of polar oils from Liaohe HO-EDWs and the biodegradability was greatly improved. Ozonation removed 33% of SCOD and 88% of polar oils from the coagulated HO-EDWs. Most species of aromatic compounds, phenols, aliphatic acids, anilines and naphthenic acids with high C numbers and ring numbers were degraded and the unsaturation degrees of DOPs significantly decreased under ozonation. As a result, the biodegradability was further improved and the acute toxicity towards Vibrio fischeri was substantially reduced. Some OxS1 species and organic nitrogen compounds in HO-EDWs were penetrated through ozonation and caused the residual biotoxicity. The results demonstrate the potential of ICO pretreatment for improving the quality of refractory HO-EDWs.
Collapse
Affiliation(s)
- Huangfan Ye
- State Key Laboratory of Heavy Oil Processing, Beijing Key Laboratory of Oil and Gas Pollution Control, China University of Petroleum-Beijing, Beijing, 102249, China
| | - Baiyu Yang
- State Key Laboratory of Heavy Oil Processing, Beijing Key Laboratory of Oil and Gas Pollution Control, China University of Petroleum-Beijing, Beijing, 102249, China
| | - Qinghong Wang
- State Key Laboratory of Heavy Oil Processing, Beijing Key Laboratory of Oil and Gas Pollution Control, China University of Petroleum-Beijing, Beijing, 102249, China
| | - Zuo Tong How
- Department of Civil and Environmental Engineering, University of Alberta, Edmonton, Alberta, T6G 1H9, Canada
| | - Chunmei Nie
- Refining & Petrochemical Research Institute, PetroChina Karamay Petrochemical Co., Ltd., Karamay, 834000, China
| | - Pamela Chelme-Ayala
- Department of Civil and Environmental Engineering, University of Alberta, Edmonton, Alberta, T6G 1H9, Canada
| | - Shaohui Guo
- State Key Laboratory of Heavy Oil Processing, Beijing Key Laboratory of Oil and Gas Pollution Control, China University of Petroleum-Beijing, Beijing, 102249, China
| | - Chunmao Chen
- State Key Laboratory of Heavy Oil Processing, Beijing Key Laboratory of Oil and Gas Pollution Control, China University of Petroleum-Beijing, Beijing, 102249, China.
| | - Mohamed Gamal El-Din
- Department of Civil and Environmental Engineering, University of Alberta, Edmonton, Alberta, T6G 1H9, Canada.
| |
Collapse
|
11
|
He C, Fang Z, Li Y, Jiang C, Zhao S, Xu C, Zhang Y, Shi Q. Ionization selectivity of electrospray and atmospheric pressure photoionization FT-ICR MS for petroleum refinery wastewater dissolved organic matter. ENVIRONMENTAL SCIENCE. PROCESSES & IMPACTS 2021; 23:1466-1475. [PMID: 34669760 DOI: 10.1039/d1em00248a] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Dissolved organic matter (DOM) in petroleum refinery wastewater is an extremely complex mixture. A better understanding of chemical compositions of DOM at the molecular level is necessary for the design and optimization of wastewater treatment processes. In this study, two largely different DOM samples, one from a petroleum refinery wastewater and the other from the Suwannee river water, were characterized by Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) coupled with positive-/negative-ion electrospray ionization (ESI), and positive-ion atmospheric pressure photoionization (APPI). For wastewater DOM, a total of 6226 molecular formulae were assigned in the three ionization modes. However, only 1182 molecular formulae were common in all three mass spectra, indicating that the techniques were highly complementary in the types of molecules they ionize. Acid Ox (x = 1-9) and basic N1Ox (x = 0-2) classes were dominant in the wastewater DOM detected in negative-ion and positive-ion ESI mode, respectively. And the wastewater DOM contains considerable amounts of polycyclic aromatic hydrocarbons that did not respond to ESI but can be ionized selectively by APPI. Compared with riverine DOM, the refinery wastewater DOM has a higher molecular complexity and is more enriched in hydrocarbon, and nitrogen- and sulfur-containing compounds. The results show that the major components of refinery wastewater DOM were distinctive from those of the natural organic matter. Though not quantitative, the results obtained by various ionization techniques were found to be complementary, and are helpful to our understanding of the selectivity of different ionization techniques as well as the molecular compositions of DOM.
Collapse
Affiliation(s)
- Chen He
- State Key Laboratory of Heavy Oil Processing, China University of Petroleum, Beijing 102249, China.
| | - Zhi Fang
- State Key Laboratory of Heavy Oil Processing, China University of Petroleum, Beijing 102249, China.
| | - Yongyong Li
- College of Food and Pharmaceutical Sciences, Ningbo University, Ningbo, Zhejiang 315211, China
| | | | - Suoqi Zhao
- State Key Laboratory of Heavy Oil Processing, China University of Petroleum, Beijing 102249, China.
| | - Chunming Xu
- State Key Laboratory of Heavy Oil Processing, China University of Petroleum, Beijing 102249, China.
| | - Yahe Zhang
- State Key Laboratory of Heavy Oil Processing, China University of Petroleum, Beijing 102249, China.
| | - Quan Shi
- State Key Laboratory of Heavy Oil Processing, China University of Petroleum, Beijing 102249, China.
| |
Collapse
|