1
|
Wenk D, Zuo C, Kislinger T, Sepiashvili L. Recent developments in mass-spectrometry-based targeted proteomics of clinical cancer biomarkers. Clin Proteomics 2024; 21:6. [PMID: 38287260 PMCID: PMC10826105 DOI: 10.1186/s12014-024-09452-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2023] [Accepted: 01/14/2024] [Indexed: 01/31/2024] Open
Abstract
Routine measurement of cancer biomarkers is performed for early detection, risk classification, and treatment monitoring, among other applications, and has substantially contributed to better clinical outcomes for patients. However, there remains an unmet need for clinically validated assays of cancer protein biomarkers. Protein tumor markers are of particular interest since proteins carry out the majority of biological processes and thus dynamically reflect changes in cancer pathophysiology. Mass spectrometry-based targeted proteomics is a powerful tool for absolute peptide and protein quantification in biological matrices with numerous advantages that make it attractive for clinical applications in oncology. The use of liquid chromatography-tandem mass spectrometry (LC-MS/MS) based methodologies has allowed laboratories to overcome challenges associated with immunoassays that are more widely used for tumor marker measurements. Yet, clinical implementation of targeted proteomics methodologies has so far been limited to a few cancer markers. This is due to numerous challenges associated with paucity of robust validation studies of new biomarkers and the labor-intensive and operationally complex nature of LC-MS/MS workflows. The purpose of this review is to provide an overview of targeted proteomics applications in cancer, workflows used in targeted proteomics, and requirements for clinical validation and implementation of targeted proteomics assays. We will also discuss advantages and challenges of targeted MS-based proteomics assays for clinical cancer biomarker analysis and highlight some recent developments that will positively contribute to the implementation of this technique into clinical laboratories.
Collapse
Affiliation(s)
- Deborah Wenk
- Princess Margaret Cancer Centre, University Health Network, Toronto, ON, Canada
| | - Charlotte Zuo
- Princess Margaret Cancer Centre, University Health Network, Toronto, ON, Canada
| | - Thomas Kislinger
- Princess Margaret Cancer Centre, University Health Network, Toronto, ON, Canada.
- Department of Medical Biophysics, University of Toronto, Toronto, ON, Canada.
- Princess Margaret Cancer Research Tower, Room 9-807, 101 College Street, Toronto, ON, M5G 1L7, Canada.
| | - Lusia Sepiashvili
- Department of Paediatric Laboratory Medicine, The Hospital for Sick Children, 555 University Ave, Rm 3606, Toronto, ON, M5G 1X8, Canada.
- Department of Laboratory Medicine & Pathobiology, University of Toronto, Toronto, ON, Canada.
- Sickkids Research Institute, Toronto, ON, Canada.
| |
Collapse
|
2
|
Yamamoto S, Kato N, Wada M, Kinoshita M. A rapid and convenient enzyme digestion method for the analysis of N-glycans using exoglycosidase-impregnated polyacrylamide gels fabricated in an automatic pipette tip. ANAL SCI 2023:10.1007/s44211-023-00314-8. [PMID: 36917436 DOI: 10.1007/s44211-023-00314-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2023] [Accepted: 03/01/2023] [Indexed: 03/16/2023]
Abstract
Efficient enzymatic digestion methods are critical for the characterization and identification of glycans. Glycan hydrolysis enzymes are widely utilized for the identification of glycoprotein or glycolipid glycans. The commonly utilized in solution glycan hydrolysis methods require several hours of incubation with enzymes for complete removal of their target monosaccharides. To develop an efficient and simple method for the rapid release of monosaccharides from glycoprotein glycans, we fabricated exoglycosidase-impregnated acrylamide gels in an automatic pipette tip. Our automated enzymatic reactors are based on the simple photochemical copolymerization of monomers comprising acrylamide and methylene-bis-acrylamide-containing enzymes with an azobis compound functioning as the photocatalytic initiator. After filling the tip of the automatic pipette with these acrylamide solutions, polymerization of the acrylamide gel solution was performed by irradiation with a LED. The immobilized enzymes maintained their activities in the pipette tips and their action was completed by fully automatic pipetting for 10 to 30 min. We utilized 8-aminopyrene-1, 3, 6-trisulfonic acid (APTS)-labeled glycans as a substrate and measured by capillary electrophoresis (CE) before and after enzymatic digestion. We demonstrated that this method exhibited quantitative enzymatic and specific cleavage of monosaccharides from glycoprotein glycans.
Collapse
Affiliation(s)
- Sachio Yamamoto
- Faculty of Pharmaceutical Sciences, Kindai University, 3-4-1, Kowakae, Higashi-osaka, Osaka, 577-8502, Japan.
| | - Naho Kato
- Faculty of Pharmaceutical Sciences, Kindai University, 3-4-1, Kowakae, Higashi-osaka, Osaka, 577-8502, Japan
| | - Miki Wada
- Faculty of Pharmaceutical Sciences, Kindai University, 3-4-1, Kowakae, Higashi-osaka, Osaka, 577-8502, Japan
| | - Mitsuhiro Kinoshita
- Faculty of Pharmaceutical Sciences, Kindai University, 3-4-1, Kowakae, Higashi-osaka, Osaka, 577-8502, Japan.,Antiaging Center, Kindai University, 3-4-1, Kowakae, Higashi-osaka, Osaka, 577-8502, Japan
| |
Collapse
|
3
|
Iannetta AA, Hicks LM. Maximizing Depth of PTM Coverage: Generating Robust MS Datasets for Computational Prediction Modeling. Methods Mol Biol 2022; 2499:1-41. [PMID: 35696073 DOI: 10.1007/978-1-0716-2317-6_1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Post-translational modifications (PTMs) regulate complex biological processes through the modulation of protein activity, stability, and localization. Insights into the specific modification type and localization within a protein sequence can help ascertain functional significance. Computational models are increasingly demonstrated to offer a low-cost, high-throughput method for comprehensive PTM predictions. Algorithms are optimized using existing experimental PTM data, thus accurate prediction performance relies on the creation of robust datasets. Herein, advancements in mass spectrometry-based proteomics technologies to maximize PTM coverage are reviewed. Further, requisite experimental validation approaches for PTM predictions are explored to ensure that follow-up mechanistic studies are focused on accurate modification sites.
Collapse
Affiliation(s)
- Anthony A Iannetta
- Department of Chemistry, University of North Carolina at Chapel Hill, Chapel Hill, NC, USA
| | - Leslie M Hicks
- Department of Chemistry, University of North Carolina at Chapel Hill, Chapel Hill, NC, USA.
| |
Collapse
|
4
|
Cui Y, Wang X, Xu J, Liu X, Wang X, Pang J, Song Y, Yu M, Song W, Luo X, Liu M, Sun S. PROTEOMIC ANALYSIS OF TAENIA SOLIUM CYST FLUID BY SHOTGUN LC-MS/MS. J Parasitol 2021; 107:799-809. [PMID: 34648630 DOI: 10.1645/20-65] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
Abstract
Taenia solium cysts were collected from pig skeletal muscle and analyzed via a shotgun proteomic approach to identify known proteins in the cyst fluid and to explore host-parasite interactions. Cyst fluid was aseptically collected and analyzed with shotgun liquid chromatography-tandem mass spectrometry (LC-MS/MS). Gene alignment and annotation were performed using Blast2GO software followed by gene ontology analysis of the annotated proteins. The pathways were further analyzed with the Kyoto Encyclopedia of Genes and Genomes (KEGG), and a protein-protein interaction (PPI) network map was generated using STRING software. A total of 158 known proteins were identified, most of which were low-molecular-mass proteins. These proteins were mainly involved in cellular and metabolic processes, and their molecular functions were predominantly related to catalytic activity and binding functions. The pathway enrichment analysis revealed that the known proteins were mainly enriched in the PI3K-Akt and glycolysis/gluconeogenesis signaling pathways. The nodes in the PPI network mainly consisted of enzymes involved in sugar metabolism. The cyst fluid proteins screened in this study may play important roles in the interaction between the cysticerci and the host. The shotgun LC-MS/MS, gene ontology, KEGG, and PPI network map data will be used to identify and analyze the cyst fluid proteome of cysticerci, which will provide a basis for further exploration of the invasion and activities of T. solium.
Collapse
Affiliation(s)
- Yaxuan Cui
- College of Animal Science and Technology, Inner Mongolia University for Nationalities, Inner Mongolia Tongliao 028042, China
| | - Xinrui Wang
- College of Animal Science and Technology, Inner Mongolia University for Nationalities, Inner Mongolia Tongliao 028042, China
| | - Jing Xu
- College of Animal Science and Technology, Inner Mongolia University for Nationalities, Inner Mongolia Tongliao 028042, China
| | - Xiaolei Liu
- Key Laboratory of Zoonosis Research, Ministry of Education, Institute of Zoonosis/College of Veterinary Medicine, Jilin University, Changchun 130000, China
| | - Xuelin Wang
- Key Laboratory of Zoonosis Research, Ministry of Education, Institute of Zoonosis/College of Veterinary Medicine, Jilin University, Changchun 130000, China
| | - Jianda Pang
- Key Laboratory of Zoonosis Research, Ministry of Education, Institute of Zoonosis/College of Veterinary Medicine, Jilin University, Changchun 130000, China
| | - Yining Song
- College of Animal Science and Technology, Inner Mongolia University for Nationalities, Inner Mongolia Tongliao 028042, China
| | - Mingchuan Yu
- College of Animal Science and Technology, Inner Mongolia University for Nationalities, Inner Mongolia Tongliao 028042, China
| | - Weiyi Song
- College of Animal Science and Technology, Inner Mongolia University for Nationalities, Inner Mongolia Tongliao 028042, China
| | - Xuenong Luo
- Key Laboratory of Veterinary Parasitology of Gansu Province, State Key Laboratory of Veterinary Etiological Biology, Lanzhou Veterinary Research Institute, Chinese Academy of Sciences, Lanzhou 730000, China
| | - Mingyuan Liu
- Key Laboratory of Zoonosis Research, Ministry of Education, Institute of Zoonosis/College of Veterinary Medicine, Jilin University, Changchun 130000, China.,Jiangsu Co-innovation Center for Prevention and Control of Important Animal Infectious Diseases and Zoonoses, Yangzhou, Jiangsu 225000, China
| | - Shumin Sun
- College of Animal Science and Technology, Inner Mongolia University for Nationalities, Inner Mongolia Tongliao 028042, China.,College of Veterinary Medicine, Yunnan Agricultural University, Kunming 650201, China
| |
Collapse
|
5
|
Robinson MR, Vasicek LA, Hoppmann C, Li M, Jokhadze G, Spellman DS. Improving the throughput of immunoaffinity purification and enzymatic digestion of therapeutic proteins using membrane-immobilized reagent technology. Analyst 2020; 145:3148-3156. [PMID: 32191233 DOI: 10.1039/d0an00190b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Continued interest in protein therapeutics has motivated the development of improved bioanalytical tools to support development programs. LC-MS offers specificity, sensitivity, and multiplexing capabilities without the need for target-specific reagents, making it a valuable alternative to ligand binding assays. Immunoaffinity purification (IP) and enzymatic digestion are critical, yet extensive and time-consuming components of the "gold standard" bottom-up approach to LC-MS-based protein quantitation. In the present work, commercially available technology, based on membrane-immobilized reagents in spin column and plate format, is applied to reduce IP and digestion times from hours to minutes. For a standard monoclonal antibody, the lower limit of quantitation was 0.1 ng μL-1 compared to 0.05 ng μL-1 for the standard method. A pharmacokinetics (PK) study dosing Herceptin in rat was analyzed by both the membrane and the standard method with a total sample processing time of 4 h and 20 h, respectively. The calculated concentrations at each time point agreed within 8% between both methods, and PK values including area under the curve (AUC), half-life (T1/2), mean residence time (MRT), clearance (CL), and volume of distribution (Vdss) agreed within 6% underscoring the utility of the membrane methodology for quantitative bioanalysis workflows.
Collapse
Affiliation(s)
- Michelle R Robinson
- Department of Pharmacokinetics Pharmacodynamics and Drug Metabolism, Merck & Co., Inc., West Point, PA, USA.
| | - Lisa A Vasicek
- Department of Pharmacokinetics Pharmacodynamics and Drug Metabolism, Merck & Co., Inc., West Point, PA, USA.
| | | | - Mandy Li
- Takara Bio USA, Inc., Mountain View, CA, USA
| | | | - Daniel S Spellman
- Department of Pharmacokinetics Pharmacodynamics and Drug Metabolism, Merck & Co., Inc., West Point, PA, USA.
| |
Collapse
|
6
|
Currivan SA, Chen WQ, Wilson R, Sanz Rodriguez E, Upadhyay N, Connolly D, Nesterenko PN, Paull B. Multi-lumen capillary based trypsin micro-reactor for the rapid digestion of proteins. Analyst 2018; 143:4944-4953. [PMID: 30221288 DOI: 10.1039/c8an01330f] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
Abstract
In this work we evaluated a novel microreactor prepared using a surface modified, high surface-to-volume ratio multi-lumen fused silica capillary (MLC). The MLC investigated contained 126 parallel channels, each of 4 μm internal diameter. The MLC, along with conventional fused silica capillaries of 25 μm and 50 μm internal diameter, were treated by (3-aminopropyl)triethoxysilane (APTES) and then modified with gold nanoparticles, of ∼20 nm in diameter, to ultimately provide immobilisation sites for the proteolytic enzyme, trypsin. The modified capillaries and MLCs were characterised and profiled using non-invasive scanning capacitively coupled contactless conductivity detection (sC4D). The sC4D profiles confirmed a significantly higher amount of enzyme was immobilised to the MLC when compared to the fused silica capillaries, attributable to the increased surface to volume ratio. The MLC was used for dynamic protein digestion, where peptide fragments were collected and subjected to off-line chromatographic evaluation. The digestion was achieved with the MLC reactor, using a residence time of just 1.26 min, following which the HPLC peak associated with the intact protein decreased by >70%. The MLC reactors behaved similarly to the classical in vitro or in-solution approach, but provided a reduction in digestion time, and fewer peaks associated with trypsin auto-digestion, which is common using in-solution digestion. The digestion of cytochrome C using both the MLC-IMER and the in-solution approach, resulted in a sequence coverage of ∼80%. The preparation of the MLC microreactor was reproducible with <2.5% RSD between reactors (n = 3) as determined by sC4D.
Collapse
Affiliation(s)
- S A Currivan
- Australian Centre for Research on Separation Science, School of Natural Sciences, University of Tasmania, Tasmania, Australia.
| | | | | | | | | | | | | | | |
Collapse
|
7
|
Liu W, Pang Y, Tan HY, Patel N, Jokhadze G, Guthals A, Bruening ML. Enzyme-containing spin membranes for rapid digestion and characterization of single proteins. Analyst 2018; 143:3907-3917. [PMID: 30039812 DOI: 10.1039/c8an00969d] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Proteolytic digestion is an important step in characterizing protein sequences and post-translational modifications (PTMs) using mass spectrometry (MS). This study uses pepsin- or trypsin-containing spin membranes for rapid digestion of single proteins or simple protein mixtures prior to ultrahigh-resolution Orbitrap MS analysis. Centrifugation of 100 μL of pretreated protein solutions through the functionalized membranes requires less than 1 min and conveniently digests proteins into large peptides that aid in confirming specific protein sequence variations and PTMs. Peptic and tryptic peptides from spin digestion of apomyoglobin and four commercial monoclonal antibodies (mAbs) typically cover 100% of the protein sequences in direct infusion MS analysis. Increasing the spin rate leads to a higher fraction of large peptic peptides for apomyoglobin, and MS analysis of peptic and tryptic peptides reveals mAb PTMs such as N-terminal pyroglutamate formation, C-terminal lysine clipping and glycosylation. Relative to overnight in-solution digestion of mAbs, spin digestion yields higher sequence coverages. Spin-membrane digestion followed by infusion MS readily differentiates a mAb to the Ebola virus from a related antibody that differs by addition of a single amino acid.
Collapse
Affiliation(s)
- Weijing Liu
- Department of Chemistry and Biochemistry, University of Notre Dame, Notre Dame, Indiana 46556, USA
| | | | | | | | | | | | | |
Collapse
|
8
|
Shen X, Sun L. Systematic Evaluation of Immobilized Trypsin-Based Fast Protein Digestion for Deep and High-Throughput Bottom-Up Proteomics. Proteomics 2018; 18:e1700432. [PMID: 29577644 DOI: 10.1002/pmic.201700432] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2017] [Revised: 03/02/2018] [Indexed: 11/08/2022]
Abstract
Immobilized trypsin (IM) has been recognized as an alternative to free trypsin (FT) for accelerating protein digestion 30 years ago. However, some questions of IM still need to be answered. How does the solid matrix of IM influence its preference for protein cleavage and how well can IM perform for deep bottom-up proteomics compared to FT? By analyzing Escherichia coli proteome samples digested with amine or carboxyl functionalized magnetic bead-based IM (IM-N or IM-C) or FT, it is observed that IM-N with the nearly neutral solid matrix, IM-C with the negatively charged solid matrix, and FT have similar cleavage preference considering the microenvironment surrounding the cleavage sites. IM-N (15 min) and FT (12 h) both approach 9000 protein identifications (IDs) from a mouse brain proteome. Compared to FT, IM-N has no bias in the digestion of proteins that are involved in various biological processes, are located in different components of cells, have diverse functions, and are expressed in varying abundance. A high-throughput bottom-up proteomics workflow comprising IM-N-based rapid protein cleavage and fast CZE-MS/MS enables the completion of protein sample preparation, CZE-MS/MS analysis, and data analysis in only 3 h, resulting in 1000 protein IDs from the mouse brain proteome.
Collapse
Affiliation(s)
- Xiaojing Shen
- Department of Chemistry, Michigan State University, East Lansing, MI, USA
| | - Liangliang Sun
- Department of Chemistry, Michigan State University, East Lansing, MI, USA
| |
Collapse
|
9
|
Yuan H, Zhang S, Zhao B, Weng Y, Zhu X, Li S, Zhang L, Zhang Y. Enzymatic Reactor with Trypsin Immobilized on Graphene Oxide Modified Polymer Microspheres To Achieve Automated Proteome Quantification. Anal Chem 2017; 89:6324-6329. [DOI: 10.1021/acs.analchem.7b00682] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Affiliation(s)
- Huiming Yuan
- CAS Key Laboratory of Separation Sciences for Analytical Chemistry, National Chromatographic R & A Center, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023, China
| | - Shen Zhang
- CAS Key Laboratory of Separation Sciences for Analytical Chemistry, National Chromatographic R & A Center, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023, China
- University of Chinese Academy of Sciences, Beijing 100049, China
| | - Baofeng Zhao
- CAS Key Laboratory of Separation Sciences for Analytical Chemistry, National Chromatographic R & A Center, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023, China
| | - Yejing Weng
- CAS Key Laboratory of Separation Sciences for Analytical Chemistry, National Chromatographic R & A Center, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023, China
- University of Chinese Academy of Sciences, Beijing 100049, China
| | - Xudong Zhu
- CAS Key Laboratory of Separation Sciences for Analytical Chemistry, National Chromatographic R & A Center, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023, China
- University of Chinese Academy of Sciences, Beijing 100049, China
| | - Senwu Li
- CAS Key Laboratory of Separation Sciences for Analytical Chemistry, National Chromatographic R & A Center, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023, China
- University of Chinese Academy of Sciences, Beijing 100049, China
| | - Lihua Zhang
- CAS Key Laboratory of Separation Sciences for Analytical Chemistry, National Chromatographic R & A Center, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023, China
| | - Yukui Zhang
- CAS Key Laboratory of Separation Sciences for Analytical Chemistry, National Chromatographic R & A Center, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023, China
| |
Collapse
|
10
|
Kecskemeti A, Gaspar A. Preparation and characterization of a packed bead immobilized trypsin reactor integrated into a PDMS microfluidic chip for rapid protein digestion. Talanta 2017; 166:275-283. [PMID: 28213235 DOI: 10.1016/j.talanta.2017.01.060] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2016] [Revised: 01/20/2017] [Accepted: 01/24/2017] [Indexed: 01/20/2023]
Abstract
This paper demonstrates the design, efficiency and applicability of a simple, inexpensive and high sample throughput microchip immobilized enzymatic reactor (IMER) for rapid protein digestion. The IMER contains conventional silica particles with covalently immobilized trypsin packed inside of a poly(dimethylsiloxane) (PDMS) microchip channel (10mm×1mm×35µm). The microchip consists of 9 different channels, enabling 9 simultaneous protein digestions. Trypsin was covalently immobilized using carbodiimide activation, the ideal trypsin/silica particle ratio (i.e. measured mass ratio before the immobilization reaction) was determined. The amount of immobilized trypsin was 10-15μg trypsin for 1mg silica particle. Migration times of CZE peptide maps showed good repeatability and reproducibility (RSD%=0.02-0.31%). The IMER maintained its activity for 2 months, in this period it was used effectively for rapid proteolysis. Four proteins (myoglobin, lysozyme, hemoglobin and albumin) in a wide size range (15-70kDa) were digested to demonstrate the applicability of the reactor. Their CZE peptide maps were compared to peptide maps obtained from standard in-solution digestion of the four proteins. The number of peptide peaks correlated well with the theoretically expected peptide number in both cases, the peak patterns of the electropherograms were similar, however, digestion with the microchip IMER requires only <10s, while in-solution digestion takes 16h. LC-MS/MS peptide mapping was also carried out, the four proteins were identified with satisfying sequence coverages (29-50%), trypsin autolysis peptides were not detected. The protein content of human serum was digested with the IMER and with in-solution digestion.
Collapse
Affiliation(s)
- Adam Kecskemeti
- Department of Inorganic and Analytical Chemistry, University of Debrecen, Egyetem ter 1, Debrecen 4032, Hungary
| | - Attila Gaspar
- Department of Inorganic and Analytical Chemistry, University of Debrecen, Egyetem ter 1, Debrecen 4032, Hungary.
| |
Collapse
|
11
|
Zhu G, Sun L, Heidbrink-Thompson J, Kuntumalla S, Lin HY, Larkin CJ, McGivney JB, Dovichi NJ. Capillary zone electrophoresis tandem mass spectrometry detects low concentration host cell impurities in monoclonal antibodies. Electrophoresis 2016; 37:616-22. [PMID: 26530276 DOI: 10.1002/elps.201500301] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2015] [Revised: 10/02/2015] [Accepted: 10/27/2015] [Indexed: 12/22/2022]
Abstract
We have evaluated CZE-ESI-MS/MS for detection of trace amounts of host cell protein impurities in recombinant therapeutics. Compared to previously published procedures, we have optimized the buffer pH used in the formation of a pH junction to increase injection volume. We also prepared a 5-point calibration curve by spiking 12 standard proteins into a solution of a human mAb. A custom CZE-MS/MS system was used to analyze the tryptic digest of this mixture without depletion of the antibody. CZE generated a ∼70-min separation window (∼90-min total analysis duration) and ∼300-peak capacity. We also analyzed the sample using ultra-performance LC-MS/MS. CZE-MS/MS generated approximately five times higher base peak intensity and more peptide identifications for low-level spiked proteins. Both methods detected all proteins spiked at ∼100 ppm level with respect to the antibody.
Collapse
Affiliation(s)
- Guijie Zhu
- Department of Chemistry and Biochemistry, University of Notre Dame, Notre Dame, IN, USA
| | - Liangliang Sun
- Department of Chemistry and Biochemistry, University of Notre Dame, Notre Dame, IN, USA
| | | | | | - Hung-yu Lin
- Department of Analytical Biotechnology, MedImmune, Gaithersburg, MD, USA
| | | | - James B McGivney
- Department of Analytical Biotechnology, MedImmune, Gaithersburg, MD, USA
| | - Norman J Dovichi
- Department of Chemistry and Biochemistry, University of Notre Dame, Notre Dame, IN, USA
| |
Collapse
|
12
|
Ning W, Bruening ML. Rapid Protein Digestion and Purification with Membranes Attached to Pipet Tips. Anal Chem 2015; 87:11984-9. [DOI: 10.1021/acs.analchem.5b03679] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Affiliation(s)
- Wenjing Ning
- Department of Chemistry, Michigan State University, East Lansing, Michigan 48824, United States
| | - Merlin L. Bruening
- Department of Chemistry, Michigan State University, East Lansing, Michigan 48824, United States
| |
Collapse
|
13
|
Dulay MT, Eberlin LS, Zare RN. Protein Analysis by Ambient Ionization Mass Spectrometry Using Trypsin-Immobilized Organosiloxane Polymer Surfaces. Anal Chem 2015; 87:12324-30. [PMID: 26567450 DOI: 10.1021/acs.analchem.5b03669] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
In the growing field of proteomic research, rapid and simple protein analysis is a crucial component of protein identification. We report the use of immobilized trypsin on hybrid organic-inorganic organosiloxane (T-OSX) polymers for the on-surface, in situ digestion of four model proteins: melittin, cytochrome c, myoglobin, and bovine serum albumin. Tryptic digestion products were sampled, detected, and identified using desorption electrospray ionization mass spectrometry (DESI-MS) and nanoDESI-MS. These novel, reusable T-OSX arrays on glass slides allow for protein digestion in methanol:water solvents (1:1, v/v) and analysis directly from the same polymer surface without the need for sample preparation, high temperature, and pH conditions typically required for in-solution trypsin digestions. Digestion reactions were conducted with 2 μL protein sample droplets (0.35 mM) at incubation temperatures of 4, 25, 37, and 65 °C and digestion reaction times between 2 and 24 h. Sequence coverages were dependent on the hydrophobicity of the OSX polymer support and varied by temperature and digestion time. Under the best conditions, the sequence coverages, determined by DESI-MS, were 100% for melittin, 100% for cytochrome c, 90% for myoglobin, and 65% for bovine serum albumin.
Collapse
Affiliation(s)
- Maria T Dulay
- Department of Chemistry, Stanford University , Stanford, California 94305, United States
| | - Livia S Eberlin
- Department of Chemistry, Stanford University , Stanford, California 94305, United States
| | - Richard N Zare
- Department of Chemistry, Stanford University , Stanford, California 94305, United States
| |
Collapse
|
14
|
Yuan H, Zhang L, Zhang Y. Preparation of high efficiency and low carry-over immobilized enzymatic reactor with methacrylic acid-silica hybrid monolith as matrix for on-line protein digestion. J Chromatogr A 2014; 1371:48-57. [PMID: 25456586 DOI: 10.1016/j.chroma.2014.10.067] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2014] [Revised: 09/05/2014] [Accepted: 10/20/2014] [Indexed: 11/28/2022]
Abstract
In this work, a novel kind of organic-silica hybrid monolith based immobilized enzymatic reactor (IMER) was developed. The monolithic support was prepared by a single step "one-pot" strategy via the polycondensation of tetramethoxysilane and vinyltrimethoxysilane and in situ copolymerization of methacrylic acid and vinyl group on the precondensed siloxanes with ammonium persulfate as the thermal initiator. Subsequently, the monolith was activated by N-(3-dimethylaminopropyl) - N'-ethylcarbodiimide (EDC) and N-hydroxysuccinimide (NHS), followed by the modification of branched polyethylenimine (PEI) to improve the hydrophilicity. Finally, after activated by EDC and NHS, trypsin was covalently immobilized onto the monolithic support. The performance of such a microreactor was evaluated by the in sequence digestion of bovine serum albumin (BSA) and myoglobin, followed by MALDI-TOF-MS analysis. Compared to those obtained by traditional in-solution digestion, not only higher sequence coverages for BSA (74±1.4% vs. 59.5±2.7%, n=6) and myoglobin (93±3% vs. 81±4.5%, n=6) were obtained, but also the digestion time was shortened from 24h to 2.5 min, demonstrating the high digestion efficiency of such an IMER. The carry-over of these two proteins on the IMER was investigated, and peptides from BSA could not be found in mass spectrum of myoglobin digests, attributed to the good hydrophilicity of our developed monolithic support. Moreover, the dynamic concentration range for protein digestion was proved to be four orders of magnitude, and the IMER could endure at least 7-day consecutive usage. Furthermore, such an IMER was coupled with nano-RPLC-ESI/MS/MS for the analysis of extracted proteins from Escherichia coli. Compared to formerly reported silica hybrid monolith based IMER and the traditional in-solution counterpart, by our developed IMER, although the identified protein number was similar, the identified distinct peptide number was improved by 7% and 25% respectively, beneficial to improve the reliability of protein identification. The IMER was further online integrated with two-dimensional nano-HPLC-MS/MS system for the analysis of protein extracts from hepatocellular carcinoma (HCC) cells with low metastasis rate, and more than 3000 protein groups were identified, with only 46 proteins identified from the residues of the IMER. All these results demonstrated that such a hybrid monolith based IMER would be of great promise in the high throughput and high confidence proteome analysis.
Collapse
Affiliation(s)
- Huiming Yuan
- Key Laboratory of Separation Science for Analytical Chemistry, National Chromatographic Research and Analysis Center, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023, China
| | - Lihua Zhang
- Key Laboratory of Separation Science for Analytical Chemistry, National Chromatographic Research and Analysis Center, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023, China.
| | - Yukui Zhang
- Key Laboratory of Separation Science for Analytical Chemistry, National Chromatographic Research and Analysis Center, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023, China
| |
Collapse
|
15
|
Sun L, Zhu G, Mou S, Zhao Y, Champion MM, Dovichi NJ. Capillary zone electrophoresis-electrospray ionization-tandem mass spectrometry for quantitative parallel reaction monitoring of peptide abundance and single-shot proteomic analysis of a human cell line. J Chromatogr A 2014; 1359:303-8. [PMID: 25082526 DOI: 10.1016/j.chroma.2014.07.024] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2014] [Revised: 06/25/2014] [Accepted: 07/10/2014] [Indexed: 12/14/2022]
Abstract
We coupled capillary zone electrophoresis (CZE) with an ultrasensitive electrokinetically pumped nanospray ionization source for tandem mass spectrometry (MS/MS) analysis of complex proteomes. We first used the system for the parallel reaction monitoring (PRM) analysis of angiotensin II spiked in 0.45mg/mL of bovine serum albumin (BSA) digest. A calibration curve was generated between the loading amount of angiotensin II and intensity of angiotensin II fragment ions. CZE-PRM generated a linear calibration curve across over 4.5 orders of magnitude dynamic range corresponding to angiotensin II loading amount from 2amole to 150fmole. The relative standard deviations (RSDs) of migration time were <4% and the RSDs of fragment ion intensity were ∼20% or less except 150fmole angiotensin II loading amount data (∼36% RSD). We further applied the system for the first bottom up proteomic analysis of a human cell line using CZE-MS/MS. We generated 283 protein identifications from a 1h long, single-shot CZE MS/MS analysis of the MCF7 breast cancer cell line digest, corresponding to ∼80ng loading amount. The MCF7 digest was fractionated using a C18 solid phase extraction column; single-shot analysis of a single fraction resulted in 468 protein identifications, which is by far the largest number of protein identifications reported for a mammalian proteomic sample using CZE.
Collapse
Affiliation(s)
- Liangliang Sun
- Department of Chemistry and Biochemistry, University of Notre Dame, Notre Dame, IN 46556, USA
| | - Guijie Zhu
- Department of Chemistry and Biochemistry, University of Notre Dame, Notre Dame, IN 46556, USA
| | - Si Mou
- Department of Chemistry and Biochemistry, University of Notre Dame, Notre Dame, IN 46556, USA
| | - Yimeng Zhao
- Department of Chemistry and Biochemistry, University of Notre Dame, Notre Dame, IN 46556, USA
| | - Matthew M Champion
- Department of Chemistry and Biochemistry, University of Notre Dame, Notre Dame, IN 46556, USA
| | - Norman J Dovichi
- Department of Chemistry and Biochemistry, University of Notre Dame, Notre Dame, IN 46556, USA.
| |
Collapse
|