Pisani AR, Rubini D, Altini C, Ruta R, Gazzilli M, Sardaro A, Iuele F, Maggialetti N, Rubini G. The Role of the 18F-FDG PET/CT in the Management of Patients Suspected of Cardiac Implantable Electronic Devices' Infection. J Pers Med 2024; 14:65. [PMID: 38248766 PMCID: PMC10820973 DOI: 10.3390/jpm14010065] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2023] [Revised: 12/11/2023] [Accepted: 12/26/2023] [Indexed: 01/23/2024] Open
Abstract
Background: Infection of Cardiac Implantable Electronic Devices (CIEDI) is a real public health problem. The main aim of this study was to determine the diagnostic performance of 18F-FDG PET/CT in the diagnosis of CIEDI. Methods: A total of 48 patients, who performed 18F-FDG PET/CT for the clinical suspicion of CIEDI were retrospectively analyzed; all patients were provided with a model with procedural recommendations before the exam. Sensitivity (Se), specificity (Sp), positive predictive value (PPV), negative predictive value (NPV) and diagnostic accuracy (DA) of 18F-FDG PET/CT were calculated; the reproducibility of qualitative analysis was assessed with Cohen's κ test. The semi-quantitative parameters (SUVmax, SQR and TBR) were evaluated in CIEDI+ and CIEDI- patients using the Student' t-test; ROC curves were elaborated to detect cut-off values. The trend of image quality with regards to procedural recommendation adherence was evaluated. Results: Se, Sp, PPV, NPV and DA were respectively 96.2%, 81.8%, 86.2%, 94.7% and 89.6%. The reproducibility of qualitative analysis was excellent (K = 0.89). Semiquantitative parameters resulted statistically different in CIEDI+ and CIEDI- patients. Cut-off values were SUVmax = 2.625, SQR = 3.766 and TBR = 1.29. Trend curves showed increasing image quality due to adherence to procedural recommendations. Conclusions:18F-FDG-PET/CT is a valid tool in the management of patients suspected of CIEDI and adherence to procedural recommendations improves its image quality.
Collapse
Affiliation(s)
- Antonio Rosario Pisani
- Interdisciplinary Department of Medicine, Section of Nuclear Medicine, University of Bari "Aldo Moro", Policlinic of Bari, Piazza Giulio Cesare 11, 70124 Bari, Italy
| | - Dino Rubini
- Radiotherapy, Precision Medicine Department, University of Campania "Luigi Vanvitelli", 80138 Naples, Italy
| | - Corinna Altini
- Interdisciplinary Department of Medicine, Section of Nuclear Medicine, University of Bari "Aldo Moro", Policlinic of Bari, Piazza Giulio Cesare 11, 70124 Bari, Italy
| | - Rossella Ruta
- Interdisciplinary Department of Medicine, Section of Nuclear Medicine, University of Bari "Aldo Moro", Policlinic of Bari, Piazza Giulio Cesare 11, 70124 Bari, Italy
| | | | - Angela Sardaro
- Interdisciplinary Department of Medicine, Section of Radiology and Radiation Oncology, University of Bari "Aldo Moro", Policlinic of Bari, Piazza Giulio Cesare 11, 70124 Bari, Italy
| | - Francesca Iuele
- Interdisciplinary Department of Medicine, Section of Nuclear Medicine, University of Bari "Aldo Moro", Policlinic of Bari, Piazza Giulio Cesare 11, 70124 Bari, Italy
| | - Nicola Maggialetti
- Interdisciplinary Department of Medicine, Section of Radiology and Radiation Oncology, University of Bari "Aldo Moro", Policlinic of Bari, Piazza Giulio Cesare 11, 70124 Bari, Italy
| | - Giuseppe Rubini
- Interdisciplinary Department of Medicine, Section of Nuclear Medicine, University of Bari "Aldo Moro", Policlinic of Bari, Piazza Giulio Cesare 11, 70124 Bari, Italy
| |
Collapse
|