1
|
Leal JA. Medial augmentation of distal femur fractures using the contralateral distal femur locking plate: A technical note. OTA Int 2024; 7:e347. [PMID: 39228878 PMCID: PMC11365623 DOI: 10.1097/oi9.0000000000000347] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2024] [Revised: 06/03/2024] [Accepted: 07/27/2024] [Indexed: 09/05/2024]
Abstract
Introduction Lateral locking plates are commonly employed for the fixation of distal femur fractures. However, scenarios involving medial comminution, extremely distal fractures, periprosthetic fractures, or nonunion could necessitate medial augmentation. This study explores the possibility of using lateral distal femoral locking plate systems for medial fixation by employing the contralateral plate. Methods This study presents a technical note on the application of lateral distal femur locking systems for medial augmentation in patients as indicated by current literature findings. Postoperative imaging modalities, including radiography and computed tomography (CT), were used to assess the plates' fit to the distal femur. Three cases following the specified technical note are presented. Results The various plate systems, all comprising distal femur locking systems, demonstrated adaptability to the medial femur anatomy as confirmed by intraoperative visualization and postoperative radiographs, including two-dimensional and three-dimensional CT scans. It has also been possible to achieve at least 3 independent fixation points regardless of the size of the medial condyle. Conclusions Locking distal femoral plates can be a viable option for medial augmentation in indicated cases, achieving anatomical adaptation to the distal femur. This provides robust augmentation without the need for additional instruments beyond those used for the lateral cortex.
Collapse
Affiliation(s)
- Jaime Andrés Leal
- Department of Orthopedic and Traumatology, Hospital Universitario de la Samaritana and Hospital Universitario Mayor de Méderi, Bogotá, Colombia
| |
Collapse
|
2
|
Leung F, Fang CX, Yung CSY, Leung FKL. Determination of the ideal plate for medial femoral condyle fracture fixation: an anatomical fit and biomechanical study. BMC Musculoskelet Disord 2024; 25:296. [PMID: 38627677 PMCID: PMC11020340 DOI: 10.1186/s12891-024-07374-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/27/2023] [Accepted: 03/21/2024] [Indexed: 04/19/2024] Open
Abstract
BACKGROUND The aim of this study is to determine the best plate to use as a substitute to fix a medial femoral condyle fracture. MATERIALS AND METHODS The first part is to measure the best fit between several anatomical plates including the Proximal Tibia Anterolateral Plate (PT AL LCP), the Proximal Tibia Medial Plate (PT M LCP), the Distal Tibia Medial Locking Plate (DT M LCP) and the Proximal Humerus (PHILOS) plate against 28 freshly embalmed cadaveric distal femurs. Measurements such as plate offset and number of screws in the condyle and shaft shall be obtained. The subsequent part is to determine the compressive force at which the plate fails. After creating an iatrogenic medial condyle fracture, the cadavers will be fixed with the two plates with the best anatomical fit and subjected to a compression force using a hydraulic press. RESULTS The PT AL LCP offered the best anatomical fit whereas the PHILOS plate offered the maximal number of screws inserted. The force required to create 2 mm of fracture displacement between the two is not statistically significant (LCP 889 N, PHILOS 947 N, p = 0.39). The PT AL LCP can withstand a larger fracture displacement than the PHILOS (LCP 24.4 mm, PHILOS 17.4 mm, p = 0.004). DISCUSSION AND CONCLUSION Both the PT AL LCP and the PHILOS remain good options in fixing a medial femoral condyle fracture. Between the two, we would recommend the PT AL LCP as the slightly superior option.
Collapse
Affiliation(s)
- Felix Leung
- Department of Orthopaedics and Traumatology, Queen Mary Hospital, 5/F, Professorial Block, 102 Pokfulam Road, Pokfulam, Hong Kong, China.
| | - Christian Xinshuo Fang
- Department of Orthopaedics and Traumatology, Queen Mary Hospital, 5/F, Professorial Block, 102 Pokfulam Road, Pokfulam, Hong Kong, China
| | - Colin Shing Yat Yung
- Department of Orthopaedics and Traumatology, Queen Mary Hospital, 5/F, Professorial Block, 102 Pokfulam Road, Pokfulam, Hong Kong, China
| | - Frankie Ka Li Leung
- Department of Orthopaedics and Traumatology, The University of Hong Kong, Hong Kong, China
| |
Collapse
|
3
|
Pastor T, Zderic I, Drenchev L, Skulev HK, Berk T, Beeres FJP, Link BC, Gueorguiev B, Stoffel K, Knobe M. Is augmented femoral lateral plating with helically shaped medial plates biomechanically advantageous over straight medial plates? J Orthop Res 2024; 42:886-893. [PMID: 37975265 DOI: 10.1002/jor.25730] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/28/2023] [Accepted: 11/14/2023] [Indexed: 11/19/2023]
Abstract
Dual plating of comminuted distal femoral fractures allows for early patient mobilization. An additional helically shaped medial plate avoids the medial vital structures of the thigh. The aim of this study is to investigate the biomechanical competence of an augmented lateral locking compression plate distal femur (LCP-DF) using an additional straight versus a helically shaped medial LCP of the same length. Ten pairs of human cadaveric femora were instrumented with a lateral anatomical 15-hole LCP-DF. Following, they were pairwise instrumented with either an additional medial straight 14-hole LCP (group 1) or a 90°-helical shape LCP (group 2). All specimens were biomechanically tested under quasi-static and progressively increasing combined cyclic axial and torsional loading until failure. Initial interfragmentary axial displacement and flexion under static compression were significantly smaller in group 1 (0.11 ± 0.12 mm and 0.21 ± 0.10°) versus group 2 (0.31 ± 0.14 mm and 0.68 ± 0.16°), p ≤ 0.007. Initial varus deformation under static compression remained not significantly different between group 1 (0.57 ± 0.23°) and group 2 (0.75 ± 0.34°), p = 0.085. Flexion movements during dynamic loading were significantly bigger in group 2 (2.51 ± 0.54°) versus group 1 (1.63 ± 1.28°), p = 0.015; however, no significant differences were observed in terms of varus, internal rotation, and axial and shear displacements between the groups, p ≥ 0.204. Cycles to failure and load at failure were higher in group 2 (25,172 ± 6376 and 3017 ± 638 N) compared to group 1 (22,277 ± 4576 and 2728 ± 458 N) with no significant differences between them, p = 0.195. From a biomechanical perspective, helical double plating may be considered a useful alternative to straight double plating, demonstrating ameliorated damping capacities during flexion deformation and safer application as the medial neurovascular structures of the thigh are avoided.
Collapse
Affiliation(s)
- Torsten Pastor
- AO Research Institute Davos, Davos, Switzerland
- Department of Orthopaedic and Trauma Surgery, Lucerne Cantonal Hospital, Lucerne, Switzerland
| | - Ivan Zderic
- AO Research Institute Davos, Davos, Switzerland
| | - Ludmil Drenchev
- Bulgarian Academy of Sciences, Institute of Metal Science "Acad. A. Balevski", Sofia, Bulgaria
| | - Hristo K Skulev
- Bulgarian Academy of Sciences, Institute of Metal Science "Acad. A. Balevski", Sofia, Bulgaria
| | - Till Berk
- AO Research Institute Davos, Davos, Switzerland
- Department of Trauma, University Hospital Zurich, Zurich, Switzerland
| | - Frank J P Beeres
- Department of Orthopaedic and Trauma Surgery, Lucerne Cantonal Hospital, Lucerne, Switzerland
- Department of Health Science and Medicine, University of Lucerne, Lucerne, Switzerland
| | - Björn-Christian Link
- Department of Orthopaedic and Trauma Surgery, Lucerne Cantonal Hospital, Lucerne, Switzerland
| | | | - Karl Stoffel
- Department of Orthopaedics and Traumatology, University Hospital Basel, Basel, Switzerland
| | - Matthias Knobe
- Department of Orthopaedic and Trauma Surgery, Lucerne Cantonal Hospital, Lucerne, Switzerland
- Medical Faculty, RWTH Aachen University Hospital, Aachen, Germany
| |
Collapse
|
4
|
Pereira S, Bidolegui F, Garabano G, Pesciallo CA, Giordano V, Pires RE, Mariolani JR, Belangero WD. Does the type of medial plate fixation matter for supplemental fixation of distal femur fractures manage with a lateral pre-contoured locked plate? A Biomechanical study. EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY & TRAUMATOLOGY : ORTHOPEDIE TRAUMATOLOGIE 2024; 34:605-612. [PMID: 37661241 DOI: 10.1007/s00590-023-03685-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/17/2023] [Accepted: 08/13/2023] [Indexed: 09/05/2023]
Abstract
INTRODUCTION Fixation of distal femur fractures with a lateral pre-contoured locking plate provides stable fixation and is the standard treatment in most cases, allowing early range of motion with a high rate of union. However, in situations, the stability achieved with the lateral plate alone may be insufficient, predisposing to fixation failure. The objective of the study was to compare, in synthetic bone models, the biomechanical behaviour of the fixation with a distal femur lateral pre-contoured locking plate solely and associated with a 3.5 mm proximal humeral locking plate applied upside down or a 4.5 mm helical locking compression plate on the medial side. MATERIAL AND METHODS A total of 15 solid synthetic left femur samples were used. A metaphysical defect at the level of the medial cortex was simulated. The samples were randomly distributed into three groups equally. All groups received a 4.5/5.0 mm single lateral 9-hole distal femur lateral pre-contoured locking plate. Group 1 had no supplementary plate. Group 2 received a supplementary 6-hole 3.5 mm proximal humeral locking plate and Group 3 received a supplementary 4.5/5.0 mm helical 14-hole narrow locking compression plate. RESULTS Both supplementary plate types used in groups 2 and 3 contributed to increase the apparent stiffness of the construct, but pairwise comparison showed statically significant difference only between group 1 and 3. No significant difference was observed between groups 2 and 3. CONCLUSION Both supplementary plates might be considered for improving the fixation in distal femur fracture in selected cases.
Collapse
Affiliation(s)
- Sebastián Pereira
- Servicio de Ortopedia y Traumatologia, Sanatorio San Lucas, Belgrano 369, B1642, San Isidro, Buenos Aires, Argentina.
- Servicio de Ortopedia y Traumatologia, Hospital Sirio-Libanes, Campana 4658, C1419, Buenos Aires, Argentina.
| | - Fernando Bidolegui
- Servicio de Ortopedia y Traumatologia, Hospital Sirio-Libanes, Campana 4658, C1419, Buenos Aires, Argentina
- Servicio de Ortopedia y Traumatologia, Sanatorio Otamendi Miroli, Azcuénaga 870, C1115, Buenos Aires, Argentina
| | - Germán Garabano
- Servicio de Ortopedia y Traumatologia, Hospital Británico de Buenos Aires, Perdriel 74, C1280 AEB, Buenos Aires, Argentina
| | - Cesar Angel Pesciallo
- Servicio de Ortopedia y Traumatologia, Hospital Británico de Buenos Aires, Perdriel 74, C1280 AEB, Buenos Aires, Argentina
| | - Vincenzo Giordano
- Serviço de Ortopedia e Traumatologia Prof. Nova Monteiro, Hospital Municipal Miguel Couto, Rio de Janeiro, Brazil
| | - Robinson Estevez Pires
- Departamento do Aparelho Locomotor, Universidade Federal de Minas Gerais, Belo Horizonte, Brazil
| | - José Ricardo Mariolani
- Biomaterials Laboratory in Orthopedics (LABIMO), Faculty of Medical Sciences, University of Campinas (UNICAMP), Campinas, SP, Brazil
| | - William Dias Belangero
- Biomaterials Laboratory in Orthopedics (LABIMO), Faculty of Medical Sciences, University of Campinas (UNICAMP), Campinas, SP, Brazil
- Department of Orthopedics, Faculty of Medical Sciences, University of Campinas (UNICAMP), Campinas, SP, Brazil
| |
Collapse
|
5
|
Ma XY, Yuan H, Cui D, Liu B, Han TY, Yu HL, Zhou DP. Management of segmental defects post open distal femur fracture using a titanium cage combined with the Masquelet technique A single-centre report of 23 cases. Injury 2023; 54:111130. [PMID: 37890289 DOI: 10.1016/j.injury.2023.111130] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/11/2023] [Revised: 09/29/2023] [Accepted: 10/13/2023] [Indexed: 10/29/2023]
Abstract
INTRODUCTION The segmental bone defects post open distal femur fracture presents a reconstructive challenge, which often requires extreme solutions. The present study reviewed a new treatment strategy which used a cylindrical titanium mesh cage as an adjunct to the Masquelet technique. METHODS We retrospectively reviewed a consecutive series of 23 patients treated for segmental bone defects post open distal femur fracture using a titanium mesh cage combined with the Masquelet technique under a 2-staged protocol in our institution from 2017 to 2021. The study group consisted of 13 men and 10 women with an average age of 44.1 years. The surgical debridement was performed with antibiotic polymethylmethacrylate (PMMA) cement spacer implanted into the bone defect combined with cement-wrapped plate stabilization, or antibiotic beads with vacuum sealing drainage (VSD) to cover the wound. The second stage of the Masquelet technique for bone defect repair began at least 4-6 weeks after the first stage, once all signs of possible infection were eliminated. After the cement spacer was removed, the definitive reconstruction was completed with exchange to a cylindrical titanium mesh cage filled with cancellous autograft within the induced membrane. The bone defect with cage was stabilized with a distal femoral Less Invasive Stabilization System (LISS). The radiological and clinical records of the enrolled patients were retrospectively analyzed. RESULTS The mean follow-up was 38.6 months. The average number of operations before the second stage was 1.3. The mean interval between the two stages was 12.7 weeks. The average length of the defect measured 8.3 cm (ranging from 6.1 to 12.4 cm). All the defects filled with autograft within the cage achieved bony union, with a mean healing time of 8.4 months. At the latest follow-up, the mean knee extension measured 6.2° (ranging from 0° to 20°), and the mean flexion measured 101.8° (ranging from 60° to 120°). Complications included two instances of superficial stitch abscess, which eventually healed. CONCLUSIONS The use of a titanium cage implanted into an induced membrane in a 2-staged Masquelet protocol could achieve satisfactory clinical outcomes in cases of segmental defects following open distal femur fractures.
Collapse
Affiliation(s)
- Xiang-Yu Ma
- Department of Orthopedics of General Hospital of Northern Theatre Command, Shenyang, Liaoning Province 110016, China
| | - Hong Yuan
- Department of Orthopedics of General Hospital of Northern Theatre Command, Shenyang, Liaoning Province 110016, China
| | - Dong Cui
- Department of Cardiology of No.967 Hospital of PLA Joint Logistics Support Force, Dalian, Liaoning Province 116011, China
| | - Bing Liu
- Department of Orthopedics of General Hospital of Northern Theatre Command, Shenyang, Liaoning Province 110016, China
| | - Tian-Yu Han
- Department of Orthopedics of General Hospital of Northern Theatre Command, Shenyang, Liaoning Province 110016, China
| | - Hai-Long Yu
- Department of Orthopedics of General Hospital of Northern Theatre Command, Shenyang, Liaoning Province 110016, China
| | - Da-Peng Zhou
- Department of Orthopedics of General Hospital of Northern Theatre Command, Shenyang, Liaoning Province 110016, China.
| |
Collapse
|
6
|
Pastor T, Zderic I, Souleiman F, Drenchev L, Skulev HK, Berk T, Gueorguiev B, Knobe M. Medial helical versus straight lateral plating of distal femoral fractures-a biomechanical comparative study. Clin Biomech (Bristol, Avon) 2023; 110:106119. [PMID: 37832469 DOI: 10.1016/j.clinbiomech.2023.106119] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/19/2023] [Revised: 10/03/2023] [Accepted: 10/04/2023] [Indexed: 10/15/2023]
Abstract
BACKGROUND Distal femoral fractures are commonly treated with lateral straight plates. However, the lateral approach may not always be desirable, and 180°-helical plates may be an alternative. AIM To investigate the biomechanical competence of 180°-helical plating versus standard straight lateral plating of unstable fractures at the distal femur. METHODS Twelve left artificial femora were instrumented with a 15-hole Locking Compression Plate-Distal Femur, using either 180°-helical plates (group 1) or conventional straight lateral plates (group 2). An unstable distal femoral fracture AO/OTA 33-A3.3 was simulated. All specimens were biomechanically tested under quasi-static and progressively increasing combined cyclic axial and torsional loading in internal rotation until failure. FINDINGS Initial axial stiffness (N/mm) was significantly higher in group 1 (185.6 ± 50.1) compared to group 2 (56.0 ± 14.4), p < 0.001. Group 1 demonstrated significantly higher initial interfragmentary flexion (°) and significantly lower initial varus/valgus deformation (°) under 500 N static axial compression versus group 2 (2.76 ± 1.02 versus 0.87 ± 0.77 and 4.08 ± 1.49 versus 6.60 ± 0.47), p ≤ 0.005. Shear displacement (mm) under 6 Nm static torsion was significantly higher in group 1 versus group 2 in both internal (1.23 ± 0.28 versus 0.40 ± 0.42) and external (1.21 ± 0.40 versus 0.57 ± 0.33) rotation, p ≤ 0.013. Cycles to failure and failure load (N) (clinical/catastrophic) were significantly higher in group 1 (12,484 ± 2116/13,752 ± 1518 and 1748.4 ± 211.6/1875.2 ± 151.8) compared to group 2 (7853 ± 1262/9727 ± 836 and 1285.3 ± 126.2/1472.7 ± 83.6), p ≤ 0.001. INTERPRETATION Although 180°-helical plating using a pre-contoured standard straight lateral plate was associated with higher shear and flexion movements, it demonstrated improved initial axial stability and resistance against varus/valgus deformation compared to straight lateral plating. Moreover, the helical plates were associated with significantly higher endurance to failure. From a biomechanical perspective, 180°-helical plating may be considered as a valuable alternative to standard straight lateral plating of unstable distal femoral fractures.
Collapse
Affiliation(s)
- Torsten Pastor
- AO Research Institute Davos, Davos, Switzerland; Department of Orthopaedic and Trauma Surgery, Lucerne Cantonal Hospital, Lucerne, Switzerland.
| | - Ivan Zderic
- AO Research Institute Davos, Davos, Switzerland
| | - Firas Souleiman
- AO Research Institute Davos, Davos, Switzerland; Department of Orthopaedics, Trauma and Plastic Surgery, University Hospital Leipzig, Leipzig, Germany
| | - Ludmil Drenchev
- Bulgarian Academy of Sciences, Institute of Metal Science "Acad. A. Balevski", Sofia, Bulgaria
| | - Hristo Kostov Skulev
- Bulgarian Academy of Sciences, Institute of Metal Science "Acad. A. Balevski", Sofia, Bulgaria
| | - Till Berk
- AO Research Institute Davos, Davos, Switzerland; Department of Trauma, University Hospital Zurich, Zurich, Switzerland
| | | | - Matthias Knobe
- Department of Orthopaedic and Trauma Surgery, Lucerne Cantonal Hospital, Lucerne, Switzerland; Medical Faculty, RWTH Aachen University Hospital, Aachen, Germany
| |
Collapse
|
7
|
Pastor T, Beeres FJP, Kastner P, Gehweiler D, Migliorini F, Nebelung S, Scaglioni MF, Souleiman F, Link BC, Babst R, Gueorguiev B, Knobe M. Anatomical analysis of different helical plate designs for distal femoral fracture fixation. Injury 2022; 53:2636-2641. [PMID: 35346508 DOI: 10.1016/j.injury.2022.03.033] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/23/2021] [Revised: 02/22/2022] [Accepted: 03/18/2022] [Indexed: 02/02/2023]
Abstract
PURPOSE Helical plates potentially avoid the medial neurovascular structures of the thigh. Two implant designs for additional medial 90° helical plate in double plate constructs for geriatric patients and 180° helical plate for single plating in young patients are potential alternatives to widely used standard straight plates. AIMS (1) assess the distances to adjacent anatomical structures being at risk when applying medial 90° and 180° helical plates with MIPO technique to the femur, (2) compare these distances with medial straight plates, and (3) correlate measurements performed during surgical dissection with CT angiography. METHODS MIPO was performed in ten human cadaveric femoral pairs using either a 90° helical 14-hole LCP (Group 1) or a 180° helical 15-hole LCP-DF (Group 2). Using CT angiography, distances between femoral arteries and plates as well as distances between plates and perforating vessels were evaluated. Following, specimens were dissected and distances determined again. All plates were removed and measurements were repeated with straight medial plates (Group 3). RESULTS Overall closest distances between plates and femoral arteries were 14.5 mm (11-19 mm) in Group 1, 21.6 mm (15-24 mm) in Group 2 and 6.5 mm (5-8 mm) in Group 3, with significant differences between Group 3 and both other groups (p < 0.001). Distances to the nearest perforating vessels were 22.4 mm (15-30 mm) in Group 1 and 1.2 mm (1-2 mm) in Group 2. Measurement techniques (visual after surgical disection and CT angiography) demonstrated a strong correlation (p < 0.010). CONCLUSIONS Inserting 90° and 180° helical plates with MIPO technique is safe, however, attention must be paid to the medial neurovascular structures with 90° helical plates and to the proximal perforating vessels with 180° helical plates. Helical plates can avoid irritation of medial neurovascular structures - compared with straight plates - although care must be taken during their distal insertion. Measurements during surgical dissection correlate with CT angiography.
Collapse
Affiliation(s)
- Torsten Pastor
- AO Research Institute Davos, Davos, Switzerland; Department of Orthopaedic and Trauma Surgery, Lucerne Cantonal Hospital, Lucerne, Switzerland.
| | - Frank J P Beeres
- Department of Orthopaedic and Trauma Surgery, Lucerne Cantonal Hospital, Lucerne, Switzerland
| | - Philipp Kastner
- AO Research Institute Davos, Davos, Switzerland; Department for Orthopaedics and Traumatology, Kepler University Hospital GmbH, Johannes Kepler University, Linz, Austria
| | | | - Filippo Migliorini
- Department of Orthopaedic, Trauma, and Reconstructive Surgery, RWTH, University of Aachen Hospital, Aachen, Germany
| | - Sven Nebelung
- Department of Radiology, University of Aachen Medical Center, Aachen, Germany
| | - Mario F Scaglioni
- Department of Plastic and Hand Surgery, Cantonal Hospital of Lucerne, Lucerne, Switzerland
| | - Firas Souleiman
- AO Research Institute Davos, Davos, Switzerland; Department of Orthopaedics, Trauma and Plastic Surgery, University Hospital Leipzig, Leipzig, Germany
| | - Björn-Christian Link
- Department of Orthopaedic and Trauma Surgery, Lucerne Cantonal Hospital, Lucerne, Switzerland
| | - Reto Babst
- Department of Orthopaedic and Trauma Surgery, Lucerne Cantonal Hospital, Lucerne, Switzerland
| | | | - Matthias Knobe
- Department of Orthopaedic and Trauma Surgery, Lucerne Cantonal Hospital, Lucerne, Switzerland
| |
Collapse
|