1
|
Pringels L, Van Valckenborgh GJ, Segers P, Chevalier A, Stepman H, Wezenbeek E, Burssens A, Vanden Bossche L. Elevated fluid and glycosaminoglycan content in the Achilles tendon contribute to higher intratendinous pressures: Implications for Achilles tendinopathy. JOURNAL OF SPORT AND HEALTH SCIENCE 2024; 13:863-871. [PMID: 38582138 PMCID: PMC11336272 DOI: 10.1016/j.jshs.2024.04.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/15/2023] [Revised: 01/17/2024] [Accepted: 02/29/2024] [Indexed: 04/08/2024]
Abstract
BACKGROUND Tendinopathy alters the compositional properties of the Achilles tendon by increasing fluid and glycosaminoglycan content. It has been speculated that these changes may affect intratendinous pressure, but the extent of this relationship remains unclear. Therefore, we aimed to investigate the impact of elevated fluid and glycosaminoglycan content on Achilles tendon intratendinous pressure and to determine whether hyaluronidase (HYAL) therapy can intervene in this potential relationship. METHODS Twenty paired fresh-frozen cadaveric Achilles tendons were mounted in a tensile-testing machine and loaded up to 5% strain. Intratendinous resting (at 0% strain) and dynamic pressure (at 5% strain) were assessed using the microcapillary infusion technique. First, intratendinous pressure was measured under native conditions before and after infusion of 2 mL physiological saline. Next, 80 mg of glycosaminoglycans were administered bilaterally to the paired tendons. The right tendons were additionally treated with 1500 units of HYAL. Finally, both groups were retested, and the glycosaminoglycan content was analyzed. RESULTS It was found that both elevated fluid and glycosaminoglycan content resulted in higher intratendinous resting and dynamic pressures (p < 0.001). HYAL treatment induced a 2.3-fold reduction in glycosaminoglycan content (p = 0.002) and restored intratendinous pressures. CONCLUSION The results of this study demonstrated that elevated fluid and glycosaminoglycan content in Achilles tendinopathy contribute to increased intratendinous resting and dynamic pressures, which can be explained by the associated increased volume and reduced permeability of the tendon matrix, respectively. HYAL degrades glycosaminoglycans sufficiently to lower intratendinous pressures and may, therefore, serve as a promising treatment.
Collapse
Affiliation(s)
- Lauren Pringels
- Department of Physical and Rehabilitation Medicine, Ghent University Hospital, Ghent 9000, Belgium; Department of Rehabilitation Sciences and Physiotherapy, Ghent University, Ghent 9000, Belgium.
| | | | - Patrick Segers
- Department of Electronics and Information Systems, Ghent University, Ghent 9000, Belgium
| | - Amélie Chevalier
- Department of Electromechanics, University of Antwerp, Antwerp 2020, Belgium
| | - Hedwig Stepman
- Department of Laboratory Medicine, Ghent University Hospital, Ghent 9000, Belgium
| | - Evi Wezenbeek
- Department of Rehabilitation Sciences and Physiotherapy, Ghent University, Ghent 9000, Belgium
| | - Arne Burssens
- Department of Orthopedic Surgery, Ghent University Hospital, Ghent 9000, Belgium
| | - Luc Vanden Bossche
- Department of Physical and Rehabilitation Medicine, Ghent University Hospital, Ghent 9000, Belgium; Department of Rehabilitation Sciences and Physiotherapy, Ghent University, Ghent 9000, Belgium
| |
Collapse
|
2
|
Aggouras AN, Connizzo BK. Earlier proteoglycan turnover promotes higher efficiency matrix remodeling in MRL/MpJ tendons. J Orthop Res 2023; 41:2261-2272. [PMID: 36866831 PMCID: PMC10475140 DOI: 10.1002/jor.25542] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/27/2022] [Revised: 01/20/2023] [Accepted: 03/01/2023] [Indexed: 03/04/2023]
Abstract
While most mammalian tissue regeneration is limited, the Murphy Roths Large (MRL/MpJ) mouse has been identified to regenerate several tissues, including tendon. Recent studies have indicated that this regenerative response is innate to the tendon tissue and not reliant on a systemic inflammatory response. Therefore, we hypothesized that MRL/MpJ mice may also exhibit a more robust homeostatic regulation of tendon structure in response to mechanical loading. To assess this, MRL/MpJ and C57BL/6J flexor digitorum longus tendon explants were subjected to stress-deprived conditions in vitro for up to 14 days. Explant tendon health (metabolism, biosynthesis, and composition), matrix metalloproteinase (MMP) activity, gene expression, and tendon biomechanics were assessed periodically. We found a more robust response to the loss of mechanical stimulus in the MRL/MpJ tendon explants, exhibiting an increase in collagen production and MMP activity consistent with previous in vivo studies. This greater collagen turnover was preceded by an early expression of small leucine-rich proteoglycans and proteoglycan-degrading MMP-3, promoting efficient regulation and organization of newly synthesized collagen and allowing for more efficient overall turnover in MRL/MpJ tendons. Therefore, mechanisms of MRL/MpJ matrix homeostasis may be fundamentally different from that of B6 tendons and may indicate better recovery from mechanical microdamage in MRL/MpJ tendons. We demonstrate here the utility of the MRL/MpJ model in elucidating mechanisms of efficient matrix turnover and its potential to shed light on new targets for more effective treatments for degenerative matrix changes brought about by injury, disease, or aging.
Collapse
Affiliation(s)
- Anthony N. Aggouras
- Department of Biomedical Engineering, Boston University, Boston, MA, 02215, United States
| | - Brianne K. Connizzo
- Department of Biomedical Engineering, Boston University, Boston, MA, 02215, United States
| |
Collapse
|
3
|
Pringels L, Cook JL, Witvrouw E, Burssens A, Vanden Bossche L, Wezenbeek E. Exploring the role of intratendinous pressure in the pathogenesis of tendon pathology: a narrative review and conceptual framework. Br J Sports Med 2023; 57:1042-1048. [PMID: 36323498 PMCID: PMC10423488 DOI: 10.1136/bjsports-2022-106066] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/13/2022] [Indexed: 02/07/2023]
Abstract
Despite the high prevalence of tendon pathology in athletes, the underlying pathogenesis is still poorly understood. Various aetiological theories have been presented and rejected in the past, but the tendon cell response model still holds true. This model describes how the tendon cell is the key regulator of the extracellular matrix and how pathology is induced by a failed adaptation to a disturbance of tissue homeostasis. Such failure has been attributed to various kinds of stressors (eg, mechanical, thermal and ischaemic), but crucial elements seem to be missing to fully understand the pathogenesis. Importantly, a disturbance of tissue pressure homeostasis has not yet been considered a possible factor, despite it being associated with numerous pathologies. Therefore, we conducted an extensive narrative literature review on the possible role of intratendinous pressure in the pathogenesis of tendon pathology. This review explores the current understanding of pressure dynamics and the role of tissue pressure in the pathogenesis of other disorders with structural similarities to tendons. By bridging these insights with known structural changes that occur in tendon pathology, a conceptual model was constituted. This model provides an overview of the possible mechanism of how an increase in intratendinous pressure might be involved in the development and progression of tendon pathology and contribute to tendon pain. In addition, some therapies that could reduce intratendinous pressure and accelerate tendon healing are proposed. Further experimental research is encouraged to investigate our hypotheses and to initiate debate on the relevance of intratendinous pressure in tendon pathology.
Collapse
Affiliation(s)
- Lauren Pringels
- Department of Physical and Rehabilitation Medicine, Ghent University Hospital, Ghent, Belgium
- Department of Rehabilitation Sciences and Physiotherapy, Ghent University, Ghent, Belgium
| | - Jill L Cook
- La Trobe Sport and Exercise Medicine Research Centre, La Trobe University, Melbourne, Victoria, Australia
| | - Erik Witvrouw
- Department of Rehabilitation Sciences and Physiotherapy, Ghent University, Ghent, Belgium
| | - Arne Burssens
- Department of Orthopaedic Surgery, Ghent University Hospital, Ghent, Belgium
| | - Luc Vanden Bossche
- Department of Physical and Rehabilitation Medicine, Ghent University Hospital, Ghent, Belgium
- Department of Rehabilitation Sciences and Physiotherapy, Ghent University, Ghent, Belgium
| | - Evi Wezenbeek
- Department of Rehabilitation Sciences and Physiotherapy, Ghent University, Ghent, Belgium
| |
Collapse
|
4
|
Muljadi PM, Andarawis-Puri N. Glycosaminoglycans modulate microscale mechanics and viscoelasticity in fatigue injured tendons. J Biomech 2023; 152:111584. [PMID: 37080079 DOI: 10.1016/j.jbiomech.2023.111584] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2022] [Revised: 03/08/2023] [Accepted: 04/05/2023] [Indexed: 04/22/2023]
Abstract
Tendinopathies are common injuries that typically occur from overuse and fatigue. Treatments target late-stage symptoms with limited success, leading to high rates of reinjury. Early intervention could halt tendinopathy progression to rupture but requires a better understanding of the biomechanical environment associated with early-stage disease. While fatigue injured tendons are further damaged by exercise that is initiated immediately after onset of injury, exercise that is initiated after a brief delay promotes repair. Similar macroscale mechanical properties and collagen damage throughout this delay period suggests that microscale, non-collagenous matrix changes after fatigue injury modulate tendon mechanotransduction and shifts the exercise response from detrimental to reparative. Glycosaminoglycans (GAGs) and proteoglycans (PGs) are increased during chronic tendinopathy, but their role in early-stage disease is unknown. We hypothesized that increased GAGs from fatigue injury modulate viscoelasticity and microscale strains to enable repair from exercise. Various GAG types were increased in the weeks after onset of fatigue injury in the extracellular and pericellular matrices of rat patellar tendons. Enzymatic removal of GAGs from these fatigued tendons increased microscale shear strain, suggesting that GAGs modulate the cell microenvironment after fatigue injury. GAG removal decreased dynamic modulus in the toe region and decreased loss tangent in the linear region of the stress-strain curve in fatigued tendons, suggesting the GAG increase modulates tendon multiscale mechanics and viscoelasticity during fiber uncrimping and fibril sliding and strain transfer. GAGs may influence repair in response to exercise and could serve as a therapeutic target for tendinopathy.
Collapse
Affiliation(s)
- Patrick M Muljadi
- Nancy E. and Peter C. Meinig School of Biomedical Engineering, Cornell University, Ithaca, NY, USA
| | - Nelly Andarawis-Puri
- Sibley School of Mechanical and Aerospace Engineering, Cornell University, Ithaca, NY, USA; Hospital for Special Surgery, New York, NY, USA.
| |
Collapse
|
5
|
Hussien AA, Niederoest B, Bollhalder M, Goedecke N, Snedeker JG. The Stiffness-Sensitive Transcriptome of Human Tendon Stromal Cells. Adv Healthc Mater 2023; 12:e2101216. [PMID: 36509005 DOI: 10.1002/adhm.202101216] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2021] [Revised: 11/20/2022] [Indexed: 12/14/2022]
Abstract
Extracellular matrix stiffness is a major regulator of cellular states. Stiffness-sensing investigations are typically performed using cells that have acquired "mechanical memory" through prolonged conditioning in rigid environments, e.g., tissue culture plastic (TCP). This potentially masks the full extent of the matrix stiffness-driven mechanosensing programs. Here, a biomaterial composed of 2D mechanovariant silicone substrates with simplified and scalable surface biofunctionalization chemistry is developed to facilitate large-scale cell culture expansion processes. Using RNA sequencing, stiffness-mediated mechano-responses of human tendon-derived stromal cells are broadly mapped. Matrix elasticity (E.) approximating tendon microscale stiffness range (E. ≈ 35 kPa) distinctly favors transcriptional programs related to chromatin remodeling and Hippo signaling; whereas compliant stiffnesses (E. ≈ 2 kPa) are enriched in processes related to cell stemness, synapse assembly, and angiogenesis. While tendon stromal cells undergo dramatic phenotypic drift on conventional TCP, mechanovariant substrates abrogate this activation with tenogenic stiffnesses inducing a transcriptional program that strongly correlates with established tendon tissue-specific expression signature. Computational inference predicts that AKT1 and ERK1/2 are major stiffness-sensing signaling hubs. Together, these findings highlight how matrix biophysical cues may dictate the transcriptional identity of tendon cells, and how matrix mechano-reciprocity regulates diverse sets of previously underappreciated mechanosensitive processes in tendon fibroblasts.
Collapse
Affiliation(s)
- Amro A Hussien
- Institute for Biomechanics, ETH Zurich, Zurich, 8092, Switzerland.,Balgrist University Hospital, University of Zurich, Zurich, 8008, Switzerland
| | - Barbara Niederoest
- Institute for Biomechanics, ETH Zurich, Zurich, 8092, Switzerland.,Balgrist University Hospital, University of Zurich, Zurich, 8008, Switzerland
| | - Maja Bollhalder
- Institute for Biomechanics, ETH Zurich, Zurich, 8092, Switzerland.,Balgrist University Hospital, University of Zurich, Zurich, 8008, Switzerland
| | - Nils Goedecke
- Institute for Biomechanics, ETH Zurich, Zurich, 8092, Switzerland.,Balgrist University Hospital, University of Zurich, Zurich, 8008, Switzerland
| | - Jess G Snedeker
- Institute for Biomechanics, ETH Zurich, Zurich, 8092, Switzerland.,Balgrist University Hospital, University of Zurich, Zurich, 8008, Switzerland
| |
Collapse
|
6
|
Júnior C, Ulldemolins A, Narciso M, Almendros I, Farré R, Navajas D, López J, Eroles M, Rico F, Gavara N. Multi-Step Extracellular Matrix Remodelling and Stiffening in the Development of Idiopathic Pulmonary Fibrosis. Int J Mol Sci 2023; 24:ijms24021708. [PMID: 36675222 PMCID: PMC9865994 DOI: 10.3390/ijms24021708] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2022] [Revised: 01/04/2023] [Accepted: 01/05/2023] [Indexed: 01/18/2023] Open
Abstract
The extracellular matrix (ECM) of the lung is a filamentous network composed mainly of collagens, elastin, and proteoglycans that provides structural and physical support to its populating cells. Proliferation, migration and overall behaviour of those cells is greatly determined by micromechanical queues provided by the ECM. Lung fibrosis displays an aberrant increased deposition of ECM which likely changes filament organization and stiffens the ECM, thus upregulating the profibrotic profile of pulmonary cells. We have previously used AFM to assess changes in the Young's Modulus (E) of the ECM in the lung. Here, we perform further ECM topographical, mechanical and viscoelastic analysis at the micro- and nano-scale throughout fibrosis development. Furthermore, we provide nanoscale correlations between topographical and elastic properties of the ECM fibres. Firstly, we identify a softening of the ECM after rats are instilled with media associated with recovery of mechanical homeostasis, which is hindered in bleomycin-instilled lungs. Moreover, we find opposite correlations between fibre stiffness and roughness in PBS- vs bleomycin-treated lung. Our findings suggest that changes in ECM nanoscale organization take place at different stages of fibrosis, with the potential to help identify pharmacological targets to hinder its progression.
Collapse
Affiliation(s)
- Constança Júnior
- Unitat de Biofísica i Bioenginyeria, Facultat de Medicina i Ciències de la Salut, Universitat de Barcelona, 08036 Barcelona, Spain
- The Institute for Bioengineering of Catalonia (IBEC), The Barcelona Institute of Science and Technology (BIST), 08028 Barcelona, Spain
| | - Anna Ulldemolins
- Unitat de Biofísica i Bioenginyeria, Facultat de Medicina i Ciències de la Salut, Universitat de Barcelona, 08036 Barcelona, Spain
- CIBER de Enfermedades Respiratorias, 28029 Madrid, Spain
- Institut d’Investigacions Biomèdiques August Pi i Sunyer, 08036 Barcelona, Spain
| | - Maria Narciso
- Unitat de Biofísica i Bioenginyeria, Facultat de Medicina i Ciències de la Salut, Universitat de Barcelona, 08036 Barcelona, Spain
- The Institute for Bioengineering of Catalonia (IBEC), The Barcelona Institute of Science and Technology (BIST), 08028 Barcelona, Spain
| | - Isaac Almendros
- Unitat de Biofísica i Bioenginyeria, Facultat de Medicina i Ciències de la Salut, Universitat de Barcelona, 08036 Barcelona, Spain
- CIBER de Enfermedades Respiratorias, 28029 Madrid, Spain
- Institut d’Investigacions Biomèdiques August Pi i Sunyer, 08036 Barcelona, Spain
| | - Ramon Farré
- Unitat de Biofísica i Bioenginyeria, Facultat de Medicina i Ciències de la Salut, Universitat de Barcelona, 08036 Barcelona, Spain
- CIBER de Enfermedades Respiratorias, 28029 Madrid, Spain
- Institut d’Investigacions Biomèdiques August Pi i Sunyer, 08036 Barcelona, Spain
| | - Daniel Navajas
- Unitat de Biofísica i Bioenginyeria, Facultat de Medicina i Ciències de la Salut, Universitat de Barcelona, 08036 Barcelona, Spain
- The Institute for Bioengineering of Catalonia (IBEC), The Barcelona Institute of Science and Technology (BIST), 08028 Barcelona, Spain
- CIBER de Enfermedades Respiratorias, 28029 Madrid, Spain
| | - Javier López
- Institut Pasteur de Lille, U1019-UMR9017-CIIL-Centre d’Infection et d’Immunité de Lille, Université de Lille, CNRS, Inserm, CHU Lille, 59000 Lille, France
| | - Mar Eroles
- Aix-Marseille, CNRS, INSERM, LAI, Centuri Centre for Living Systems, 13009 Marseille, France
| | - Felix Rico
- Aix-Marseille, CNRS, INSERM, LAI, Centuri Centre for Living Systems, 13009 Marseille, France
| | - Núria Gavara
- Unitat de Biofísica i Bioenginyeria, Facultat de Medicina i Ciències de la Salut, Universitat de Barcelona, 08036 Barcelona, Spain
- The Institute for Bioengineering of Catalonia (IBEC), The Barcelona Institute of Science and Technology (BIST), 08028 Barcelona, Spain
- Correspondence:
| |
Collapse
|
7
|
Tsvirkun D, Revilloud J, Giannetti A, Verdier C. The intriguing role of collagen on the rheology of cancer cell spheroids. J Biomech 2022; 141:111229. [DOI: 10.1016/j.jbiomech.2022.111229] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2022] [Revised: 06/17/2022] [Accepted: 07/18/2022] [Indexed: 10/16/2022]
|
8
|
Orozco GA, Tanska P, Gustafsson A, Korhonen RK, Isaksson H. Crack propagation in articular cartilage under cyclic loading using cohesive finite element modeling. J Mech Behav Biomed Mater 2022; 131:105227. [DOI: 10.1016/j.jmbbm.2022.105227] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2021] [Revised: 03/01/2022] [Accepted: 04/02/2022] [Indexed: 11/28/2022]
|
9
|
Chatterjee M, Muljadi PM, Andarawis-Puri N. The role of the tendon ECM in mechanotransduction: disruption and repair following overuse. Connect Tissue Res 2022; 63:28-42. [PMID: 34030531 DOI: 10.1080/03008207.2021.1925663] [Citation(s) in RCA: 18] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
Purpose: Tendon overuse injuries are prevalent conditions with limited therapeutic options to halt disease progression. The specialized extracellular matrix (ECM) both enables joint function and mediates mechanical signals to tendon cells, driving biological responses to exercise or injury. With overuse, tendon ECM composition and structure changes at multiple scales, disrupting mechanotransduction and resulting in inadequate repair and disease progression. This review highlights the multiscale ECM changes that occur with tendon overuse and corresponding effects on cell-matrix interactions and cellular response to load.Results: Different functional joint requirements and tendon types experience a wide range of loading profiles, creating varied downstream mechanical stimuli. Distinct ECM structure and mechanical properties within the fascicle matrix, interfascicle matrix, and enthesis and their varied disruption with overuse are considered. The pericellular matrix (PCM) comprising the microscale tendon cell environment has a unique composition that changes with overuse injury and exercise, suggesting an important role in mechanotransduction and promoting repair. Cell-matrix interactions are mediated by structures including cilia, integrins, connexins and cytoskeleton that signal downstream homeostasis, adaptation, or repair. ECM disruption with tendon overuse may cause altered mechanical loading and cell-matrix interactions, resulting in mechanobiological understimulation, apoptosis, and ineffective repair. Current interventions to promote repair of tendon overuse injuries including exercise, targeting cell signaling, and modulating inflammation are considered.Conclusion: Future therapeutics should be assessed with regard of their effects on multiscale mechanotransduction in addition to joint function, with consideration of the central role of ECM.
Collapse
Affiliation(s)
- Monideepa Chatterjee
- Nancy E. And Peter C. Meinig School of Biomedical Engineering, Cornell University, Ithaca, New York, USA
| | - Patrick M Muljadi
- Nancy E. And Peter C. Meinig School of Biomedical Engineering, Cornell University, Ithaca, New York, USA
| | - Nelly Andarawis-Puri
- Nancy E. And Peter C. Meinig School of Biomedical Engineering, Cornell University, Ithaca, New York, USA.,Sibley School of Mechanical and Aerospace Engineering, Cornell University, Ithaca, New York, USA.,Hospital for Special Surgery, New York, New York, USA
| |
Collapse
|
10
|
Safa BN, Read AT, Ethier CR. Assessment of the viscoelastic mechanical properties of the porcine optic nerve head using micromechanical testing and finite element modeling. Acta Biomater 2021; 134:379-387. [PMID: 34274532 PMCID: PMC8542610 DOI: 10.1016/j.actbio.2021.07.022] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2021] [Revised: 06/11/2021] [Accepted: 07/08/2021] [Indexed: 11/26/2022]
Abstract
Optic nerve head (ONH) biomechanics is centrally involved in the pathogenesis of glaucoma, a blinding ocular condition often characterized by elevation and fluctuation of the intraocular pressure and resulting loads on the ONH. Further, tissue viscoelasticity is expected to strongly influence the mechanical response of the ONH to mechanical loading, yet the viscoelastic mechanical properties of the ONH remain unknown. To determine these properties, we conducted micromechanical testing on porcine ONH tissue samples, coupled with finite element modeling based on a mixture model consisting of a biphasic material with a viscoelastic solid matrix. Our results provide a detailed description of the viscoelastic properties of the porcine ONH at each of its four anatomical quadrants (i.e., nasal, superior, temporal, and inferior). We showed that the ONH's viscoelastic mechanical response can be explained by a dual mechanism of fluid flow and solid matrix viscoelasticity, as is common in other soft tissues. We obtained porcine ONH properties as follows: matrix Young's modulus E=1.895[1.056,2.391] kPa (median [min., max.]), Poisson's ratio ν=0.142[0.060,0.312], kinetic time-constant τ=214[89,921] sec, and hydraulic permeability k=3.854×10-1[3.457×10-2,9.994×10-1] mm4/(N.sec). These values can be used to design and fabricate physiologically appropriate ex vivo test environments (e.g., 3D cell culture) to further understand glaucoma pathophysiology. STATEMENT OF SIGNIFICANCE: Optic nerve head (ONH) biomechanics is an important aspect of the pathogenesis of glaucoma, the leading cause of irreversible blindness. The ONH experiences time-varying loads, yet the viscoelastic behavior of this tissue has not been characterized. Here, we measure the time-dependent response of the ONH in porcine eyes and use mechanical modeling to provide time-dependent mechanical properties of the ONH. This information allows us to identify time-varying stimuli in vivo which have timescales matching the characteristic response times of the ONH, and can also be used to design and fabricate ex vivo 3D cultures to study glaucoma pathophysiology in a physiologically relevant environment, enabling the discovery of new generations of glaucoma medications focusing on neuroprotection.
Collapse
Affiliation(s)
- Babak N Safa
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology/Emory University, Atlanta GA, USA
| | - A Thomas Read
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology/Emory University, Atlanta GA, USA
| | - C Ross Ethier
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology/Emory University, Atlanta GA, USA.
| |
Collapse
|
11
|
Zitnay JL, Lin AH, Weiss JA. Tendons exhibit greater resistance to tissue and molecular-level damage with increasing strain rate during cyclic fatigue. Acta Biomater 2021; 134:435-442. [PMID: 34314889 DOI: 10.1016/j.actbio.2021.07.045] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2021] [Revised: 07/15/2021] [Accepted: 07/21/2021] [Indexed: 11/28/2022]
Abstract
Musculoskeletal soft connective tissues are commonly injured due to repetitive use, but the evolution of mechanical damage to the tissue structure during repeated loading is poorly understood. We investigated the strain-rate dependence of mechanical denaturation of collagen as a form of structural microdamage accumulation during creep fatigue loading of rat tail tendon fascicles. We cycled tendons at three strain rates to the same maximum stress relative to their rate-dependent tensile strength. Collagen denaturation at distinct points during the fatigue process was measured by fluorescence quantification of collagen hybridizing peptide binding. The amount of collagen denaturation was significantly correlated with fascicle creep strain, independent of the cyclic strain rate, supporting our hypothesis that tissue level creep is caused by collagen triple-helix unfolding. Samples that were loaded faster experienced more creep strain and denaturation as a function of the number of loading cycles relative to failure. Although this increased damage capacity at faster rates may serve as a protective measure during high-rate loading events, it may also predispose these tissues to subsequent injury and indicate a mechanism of overuse injury development. These results build on evidence that molecular-level collagen denaturation is the fundamental mechanism of structural damage to tendons during tensile loading. STATEMENT OF SIGNIFICANCE: This study is the first to investigate the accumulation of denatured collagen in tendons throughout fatigue loading when the maximum stress is scaled with the applied strain rate. The amount of denatured collagen was correlated with creep strain, independent of strain rate, but samples that were cycled faster withstood greater amounts of denaturation before failure. Differential accumulation of collagen damage between fast and slow repetitive loading has relevance toward understanding the prevalence of overuse musculoskeletal injuries following sudden changes in activity level. Since collagen is a ubiquitous biological structural component, the basic patterns and mechanisms of loading-induced collagen damage in connective tissues are relevant for understanding injury and disease in other tissues, including those from the cardiovascular and pulmonary systems.
Collapse
Affiliation(s)
- Jared L Zitnay
- Department of Biomedical Engineering, University of Utah, Salt Lake City, UT, USA; Scientific Computing and Imaging Institute, University of Utah, Salt Lake City, UT, USA
| | - Allen H Lin
- Department of Biomedical Engineering, University of Utah, Salt Lake City, UT, USA; Scientific Computing and Imaging Institute, University of Utah, Salt Lake City, UT, USA
| | - Jeffrey A Weiss
- Department of Biomedical Engineering, University of Utah, Salt Lake City, UT, USA; Scientific Computing and Imaging Institute, University of Utah, Salt Lake City, UT, USA; Department of Orthopaedics, University of Utah, Salt Lake City, UT, USA; School of Computing, University of Utah, Salt Lake City, UT, USA.
| |
Collapse
|
12
|
Viscoelastic Properties in Cancer: From Cells to Spheroids. Cells 2021; 10:cells10071704. [PMID: 34359874 PMCID: PMC8304080 DOI: 10.3390/cells10071704] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2021] [Revised: 06/28/2021] [Accepted: 06/30/2021] [Indexed: 12/24/2022] Open
Abstract
AFM-based rheology methods enable the investigation of the viscoelastic properties of cancer cells. Such properties are known to be essential for cell functions, especially for malignant cells. Here, the relevance of the force modulation method was investigated to characterize the viscoelasticity of bladder cancer cells of various invasiveness on soft substrates, revealing that the rheology parameters are a signature of malignancy. Furthermore, the collagen microenvironment affects the viscoelastic moduli of cancer cell spheroids; thus, collagen serves as a powerful proxy, leading to an increase of the dynamic moduli vs. frequency, as predicted by a double power law model. Taken together, these results shed new light on how cancer cells and tissues adapt their viscoelastic properties depending on their malignancy and the microenvironment. This method could be an attractive way to control their properties in the future, based on the similarity of spheroids with in vivo tumor models.
Collapse
|
13
|
Xu H, Liang T, Wei L, Zhu JC, Liu X, Ji CC, Liu B, Luo ZP. Nano-elastic modulus of tendon measured directly in living mice. J Biomech 2021; 116:110248. [PMID: 33485146 DOI: 10.1016/j.jbiomech.2021.110248] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2020] [Revised: 12/23/2020] [Accepted: 01/03/2021] [Indexed: 01/16/2023]
Abstract
The nano-biomechanical environment of the extracellular matrix is critical for cells to sense and respond to mechanical loading. However, to date, this important characteristic remains poorly understood in living tissue structures. This study reports the experimental measurement of the in vivo nano-elastic modulus of the tendon in a mouse tail model. The experiment was performed on the tail tendon of an 8-week-old C57BL/6 live mouse. Mechanical loading on tail tendons was regulated by changing both voltage and frequency of alternating current stimulation on the erector spinae. The nano-elastic modulus of the tail tendon was measured by atomic force microscope. The nano-elastic modulus showed significant variation (2.19-35.70 MPa) between different locations and up to 39% decrease under muscle contraction, suggesting a complicated biomechanical environment in which cells dwell. In addition, the nano-elastic modulus of the tail tendon measured in live mice was significantly lower than that measured in vitro, suggesting a disagreement of tissue mechanical properties in vivo and in vitro. This information is important for the designs of new extracellular biomaterial that can better mimic the biological environment, and improve clinical outcomes of musculoskeletal tissue degenerations and associated disorders.
Collapse
Affiliation(s)
- Hao Xu
- Orthopedic Institute, Medical College, Soochow University, Suzhou, PR China; Orthopaedic Institute, Department of Orthopaedics, The First Affiliated Hospital of Soochow University, Suzhou, PR China
| | - Ting Liang
- Orthopedic Institute, Medical College, Soochow University, Suzhou, PR China; Orthopaedic Institute, Department of Orthopaedics, The First Affiliated Hospital of Soochow University, Suzhou, PR China
| | - Liangyi Wei
- Orthopaedic Institute, Department of Orthopaedics, The First Affiliated Hospital of Soochow University, Suzhou, PR China
| | - Jun-Cheng Zhu
- Orthopaedic Institute, Department of Orthopaedics, The First Affiliated Hospital of Soochow University, Suzhou, PR China
| | - Xuhui Liu
- San Francisco Veterans Affairs Health Care System, and Department of Orthopedic Surgery, University of California at San Francisco, 1700 Owens Street, Room 364, San Francisco, CA 94158, USA
| | - Chen-Chen Ji
- Orthopaedic Institute, Department of Orthopaedics, The First Affiliated Hospital of Soochow University, Suzhou, PR China
| | - Bo Liu
- Orthopaedic Institute, Department of Orthopaedics, The First Affiliated Hospital of Soochow University, Suzhou, PR China
| | - Zong-Ping Luo
- Orthopedic Institute, Medical College, Soochow University, Suzhou, PR China; Orthopaedic Institute, Department of Orthopaedics, The First Affiliated Hospital of Soochow University, Suzhou, PR China.
| |
Collapse
|
14
|
Siadat SM, Zamboulis DE, Thorpe CT, Ruberti JW, Connizzo BK. Tendon Extracellular Matrix Assembly, Maintenance and Dysregulation Throughout Life. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2021; 1348:45-103. [PMID: 34807415 DOI: 10.1007/978-3-030-80614-9_3] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
Abstract
In his Lissner Award medal lecture in 2000, Stephen Cowin asked the question: "How is a tissue built?" It is not a new question, but it remains as relevant today as it did when it was asked 20 years ago. In fact, research on the organization and development of tissue structure has been a primary focus of tendon and ligament research for over two centuries. The tendon extracellular matrix (ECM) is critical to overall tissue function; it gives the tissue its unique mechanical properties, exhibiting complex non-linear responses, viscoelasticity and flow mechanisms, excellent energy storage and fatigue resistance. This matrix also creates a unique microenvironment for resident cells, allowing cells to maintain their phenotype and translate mechanical and chemical signals into biological responses. Importantly, this architecture is constantly remodeled by local cell populations in response to changing biochemical (systemic and local disease or injury) and mechanical (exercise, disuse, and overuse) stimuli. Here, we review the current understanding of matrix remodeling throughout life, focusing on formation and assembly during the postnatal period, maintenance and homeostasis during adulthood, and changes to homeostasis in natural aging. We also discuss advances in model systems and novel tools for studying collagen and non-collagenous matrix remodeling throughout life, and finally conclude by identifying key questions that have yet to be answered.
Collapse
Affiliation(s)
| | - Danae E Zamboulis
- Institute of Life Course and Medical Sciences, Faculty of Health and Life Sciences, University of Liverpool, Liverpool, UK
| | - Chavaunne T Thorpe
- Comparative Biomedical Sciences, The Royal Veterinary College, University of London, London, UK
| | - Jeffrey W Ruberti
- Department of Bioengineering, Northeastern University, Boston, MA, USA
| | - Brianne K Connizzo
- Department of Biomedical Engineering, Boston University, Boston, MA, USA.
| |
Collapse
|
15
|
Connizzo BK, Sun L, Lacin N, Gendelman A, Solomonov I, Sagi I, Grodzinsky AJ, Naveh GRS. Nonuniformity in Periodontal Ligament: Mechanics and Matrix Composition. J Dent Res 2020; 100:179-186. [PMID: 33043806 DOI: 10.1177/0022034520962455] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022] Open
Abstract
The periodontal ligament (PDL) plays a critical role in providing immediate response to abrupt high loads during mastication while also facilitating slow remodeling of the alveolar bone. The PDL exceptional functionality is permitted by the unique nonuniform structure of the tissue. Two distinct areas that are critical to PDL function were previously identified: the furcation and the dense collar. Despite their hypothesized functions in tooth movement and maintenance, these 2 regions have not yet been compared within the context of their native environment. Therefore, the objective of this study is to elucidate the extracellular matrix (ECM) structure, composition, and biomechanical function of the furcation and the collar regions while maintaining the 3-dimensional (3D) structure in the murine PDL. We identify significant difference between the collar and furcation regions in both structure and mechanical properties. Specifically, we observed unique longitudinal structures in the dense collar that correlate with type VI collagen and LOX, both of which are associated with increased type I collagen density and tissue stiffness and are therefore proposed to function as scaffolds for tooth stabilization. We also found that the collar region is stiffer than the furcation region and therefore suggest that the dense collar acts as a suspense structure of the tooth within the bone during physiological loading. The furcation region of the PDL contained more proteins associated with reduced stiffness and higher tissue remodeling, as well as a dual mechanical behavior, suggesting a critical function in loads transfer and remodeling of the alveolar bone. In summary, this work unravels the nonuniform nature of the PDL within the 3D structural context and establishes understanding of regional PDL function, which opens new avenues for future studies of remodeling, regeneration, and disease.
Collapse
Affiliation(s)
- B K Connizzo
- Department of Biological Engineering, Massachusetts Institute of Technology, Cambridge, MA, USA
| | - L Sun
- Department of Oral Medicine, Infection and Immunity, School of Dental Medicine, Harvard University, Boston, MA, USA
| | - N Lacin
- Department of Oral Medicine, Infection and Immunity, School of Dental Medicine, Harvard University, Boston, MA, USA
| | - A Gendelman
- Department of Oral Medicine, Infection and Immunity, School of Dental Medicine, Harvard University, Boston, MA, USA
| | - I Solomonov
- Department of Biological Regulation, Weizmann Institute of Science, Rehovot, Israel
| | - I Sagi
- Department of Biological Regulation, Weizmann Institute of Science, Rehovot, Israel
| | - A J Grodzinsky
- Department of Biological Engineering, Massachusetts Institute of Technology, Cambridge, MA, USA.,Center for Biomedical Engineering, Massachusetts Institute of Technology, Cambridge, MA, USA.,Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, MA, USA.,Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA, USA
| | - G R S Naveh
- Department of Oral Medicine, Infection and Immunity, School of Dental Medicine, Harvard University, Boston, MA, USA
| |
Collapse
|
16
|
Connizzo BK, Naveh GRS. In situ AFM-based nanoscale rheology reveals regional non-uniformity in viscoporoelastic mechanical behavior of the murine periodontal ligament. J Biomech 2020; 111:109996. [PMID: 32861150 DOI: 10.1016/j.jbiomech.2020.109996] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2020] [Revised: 08/04/2020] [Accepted: 08/08/2020] [Indexed: 12/16/2022]
Abstract
The periodontal ligament (PDL) is a critical player in the maintenance of tooth health, acting as the primary stabilizer of tooth position. Recent studies have identified two unique regions within the PDL, the 'dense collar' region and the 'furcation' region, which exhibit distinct structural and compositional differences. However, specific functional differences between these regions have yet to be investigated. We adapted an AFM-based nanoscale rheology method to regionally assess mechanical properties and poroelasticity in the mouse PDL while minimizing the disruption of the 3-dimensional native boundary conditions, and then explored tissue mechanical function in four different regions within the dense collar as well as in the furcation region. We found significant differences between the collar and furcation regions, with the collar acting as a stabilizing ligamentous structure and the furcation acting as both a compressive cushion for vertical forces and a conduit for nutrient transport. While this finding supports our hypothesis, based on previous studies investigating structural and compositional differences, we also found surprising inhomogeneity within the collar region itself. This inhomogeneity supports previous findings of a tilting movement in the buccal direction of mandibular molar teeth and the structural adaptation to prevent lingual movement. Future work will aim to understand how different regions of the PDL change functionally during biological or mechanical perturbations, such as orthodontic tooth movement, development, or aging, with the ultimate goal of better understanding the mechanobiology of the PDL function in health and disease.
Collapse
Affiliation(s)
- Brianne K Connizzo
- Department of Biological Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, United States.
| | - Gili R S Naveh
- Department of Oral Medicine, Infection and Immunity, School of Dental Medicine, Harvard University, Boston, MA 02115, United States
| |
Collapse
|
17
|
Zitnay JL, Jung GS, Lin AH, Qin Z, Li Y, Yu SM, Buehler MJ, Weiss JA. Accumulation of collagen molecular unfolding is the mechanism of cyclic fatigue damage and failure in collagenous tissues. SCIENCE ADVANCES 2020; 6:eaba2795. [PMID: 32923623 PMCID: PMC7455178 DOI: 10.1126/sciadv.aba2795] [Citation(s) in RCA: 39] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/22/2020] [Accepted: 07/14/2020] [Indexed: 05/04/2023]
Abstract
Overuse injuries to dense collagenous tissues are common, but their etiology is poorly understood. The predominant hypothesis that micro-damage accumulation exceeds the rate of biological repair is missing a mechanistic explanation. Here, we used collagen hybridizing peptides to measure collagen molecular damage during tendon cyclic fatigue loading and computational simulations to identify potential explanations for our findings. Our results revealed that triple-helical collagen denaturation accumulates with increasing cycles of fatigue loading, and damage is correlated with creep strain independent of the cyclic strain rate. Finite-element simulations demonstrated that biphasic fluid flow is a possible fascicle-level mechanism to explain the rate dependence of the number of cycles and time to failure. Molecular dynamics simulations demonstrated that triple-helical unfolding is rate dependent, revealing rate-dependent mechanisms at multiple length scales in the tissue. The accumulation of collagen molecular denaturation during cyclic loading provides a long-sought "micro-damage" mechanism for the development of overuse injuries.
Collapse
Affiliation(s)
- Jared L. Zitnay
- Department of Biomedical Engineering, University of Utah, Salt Lake City, UT 84112, USA
- Scientific Computing and Imaging Institute, University of Utah, Salt Lake City, UT 84112, USA
| | - Gang Seob Jung
- Laboratory for Atomistic and Molecular Mechanics, Department of Civil and Environmental Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Allen H. Lin
- Department of Biomedical Engineering, University of Utah, Salt Lake City, UT 84112, USA
- Scientific Computing and Imaging Institute, University of Utah, Salt Lake City, UT 84112, USA
| | - Zhao Qin
- Laboratory for Atomistic and Molecular Mechanics, Department of Civil and Environmental Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Yang Li
- Department of Biomedical Engineering, University of Utah, Salt Lake City, UT 84112, USA
| | - S. Michael Yu
- Department of Biomedical Engineering, University of Utah, Salt Lake City, UT 84112, USA
- Department of Pharmaceutics and Pharmaceutical Chemistry, University of Utah, Salt Lake City, UT 84132, USA
| | - Markus J. Buehler
- Laboratory for Atomistic and Molecular Mechanics, Department of Civil and Environmental Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Jeffrey A. Weiss
- Department of Biomedical Engineering, University of Utah, Salt Lake City, UT 84112, USA
- Scientific Computing and Imaging Institute, University of Utah, Salt Lake City, UT 84112, USA
- Department of Orthopaedics and School of Computing, University of Utah, Salt Lake City, UT 84112, USA
- Corresponding author.
| |
Collapse
|
18
|
Safa BN, Bloom ET, Lee AH, Santare MH, Elliott DM. Evaluation of transverse poroelastic mechanics of tendon using osmotic loading and biphasic mixture finite element modeling. J Biomech 2020; 109:109892. [PMID: 32807341 DOI: 10.1016/j.jbiomech.2020.109892] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2019] [Revised: 05/15/2020] [Accepted: 06/09/2020] [Indexed: 12/14/2022]
Abstract
Tendon's viscoelastic behaviors are important to the tissue mechanical function and cellular mechanobiology. When loaded in longitudinal tension, tendons often have a large Poisson's ratio (ν>2) that exceeds the limit of incompressibility for isotropic material (ν=0.5), indicating that tendon experiences volume loss, inducing poroelastic fluid exudation in the transverse direction. Therefore, transverse poroelasticity is an important contributor to tendon material behavior. Tendon hydraulic permeability which is required to evaluate the fluid flow contribution to viscoelasticity, is mostly unavailable, and where available, varies by several orders of magnitude. In this manuscript, we quantified the transverse poroelastic material parameters of rat tail tendon fascicles by conducting transverse osmotic loading experiments, in both tension and compression. We used a multi-start optimization method to evaluate the parameters using biphasic finite element modeling. Our tendon samples had a transverse hydraulic permeability of 10-4 to 10-5 mm4. (Ns)-1 and showed a significant tension-compression nonlinearity in the transverse direction. Further, using these results, we predict hydraulic permeability during longitudinal (fiber-aligned) tensile loading, and the spatial distribution of fluid flow during osmotic loading. These results reveal novel aspects of tendon mechanics and can be used to study the physiomechanical response of tendon in response to mechanical loading.
Collapse
Affiliation(s)
- Babak N Safa
- Department of Mechanical Engineering, University of Delaware, Newark, DE, United States; Department of Biomedical Engineering, University of Delaware, Newark, DE, United States
| | - Ellen T Bloom
- Department of Biomedical Engineering, University of Delaware, Newark, DE, United States
| | - Andrea H Lee
- Department of Biomedical Engineering, University of Delaware, Newark, DE, United States
| | - Michael H Santare
- Department of Mechanical Engineering, University of Delaware, Newark, DE, United States; Department of Biomedical Engineering, University of Delaware, Newark, DE, United States
| | - Dawn M Elliott
- Department of Biomedical Engineering, University of Delaware, Newark, DE, United States.
| |
Collapse
|
19
|
Zhang J, Chada NC, Reinhart-King CA. Microscale Interrogation of 3D Tissue Mechanics. Front Bioeng Biotechnol 2019; 7:412. [PMID: 31921816 PMCID: PMC6927918 DOI: 10.3389/fbioe.2019.00412] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2019] [Accepted: 11/28/2019] [Indexed: 01/02/2023] Open
Abstract
Cells in vivo live in a complex microenvironment composed of the extracellular matrix (ECM) and other cells. Growing evidence suggests that the mechanical interaction between the cells and their microenvironment is of critical importance to their behaviors under both normal and diseased conditions, such as migration, differentiation, and proliferation. The study of tissue mechanics in the past two decades, including the assessment of both mechanical properties and mechanical stresses of the extracellular microenvironment, has greatly enriched our knowledge about how cells interact with their mechanical environment. Tissue mechanical properties are often heterogeneous and sometimes anisotropic, which makes them difficult to obtain from macroscale bulk measurements. Mechanical stresses were first measured for cells cultured on two-dimensional (2D) surfaces with well-defined mechanical properties. While 2D measurements are relatively straightforward and efficient, and they have provided us with valuable knowledge on cell-ECM interactions, that knowledge may not be directly applicable to in vivo systems. Hence, the measurement of tissue stresses in a more physiologically relevant three-dimensional (3D) environment is required. In this mini review, we will summarize and discuss recent developments in using optical, magnetic, genetic, and mechanical approaches to interrogate 3D tissue stresses and mechanical properties at the microscale.
Collapse
|
20
|
Water-content related alterations in macro and micro scale tendon biomechanics. Sci Rep 2019; 9:7887. [PMID: 31133713 PMCID: PMC6536550 DOI: 10.1038/s41598-019-44306-z] [Citation(s) in RCA: 48] [Impact Index Per Article: 9.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2019] [Accepted: 05/14/2019] [Indexed: 11/17/2022] Open
Abstract
Though it is known that the water content of biological soft tissues alters mechanical properties, little attempt has been made to adjust the tissue water content prior to biomechanical testing as part of standardization procedures. The objective of this study was to examine the effects of altered water content on the macro and micro scale mechanical tissues properties. Human iliotibial band samples were obtained during autopsies to osmotically adapt their water content. Macro mechanical tensile testing of the samples was conducted with digital image correlation, and micro mechanical tests using atomic force microscopy. Analyses were conducted for elastic moduli, tensile strength, and strain at maximum force, and correlations for water content, anthropometric data, and post-mortem interval. Different mechanical properties exist at different water concentrations. Correlations to anthropometric data are more likely to be found at water concentrations close to the native state. These data underline the need for adapting the water content of soft tissues for macro and micro biomechanical experiments to optimize their validity. The osmotic stress protocol provides a feasible and reliable standardization approach to adjust for water content-related differences induced by age at death, post-mortem interval and tissue processing time with known impact on the stress-strain properties.
Collapse
|
21
|
Safa B, Lee A, Santare MH, Elliott DM. Evaluating Plastic Deformation and Damage as Potential Mechanisms for Tendon Inelasticity using a Reactive Modeling Framework. J Biomech Eng 2019; 141:2731931. [PMID: 31004138 DOI: 10.1115/1.4043520] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2018] [Indexed: 12/12/2022]
Abstract
Inelastic behaviors, such as softening, a progressive decrease in modulus before failure, occur in tendon and are important aspect in degeneration and tendinopathy. These inelastic behaviors are generally attributed to two potential mechanisms: plastic deformation and damage. However, it is not clear which is primarily responsible. In this study, we evaluated these potential mechanisms of tendon inelasticity by using a recently developed reactive inelasticity model (RIE), which is a structurally-inspired continuum mechanics framework that models tissue inelasticity based on the molecular bond kinetics. Using RIE, we formulated two material models, one specific to plastic deformation and the other to damage. The models were independently fit to published experimental tensile tests of rat tail tendons. We quantified the inelastic effects and compared the performance of the two models in fitting the mechanical response during loading, relaxation, unloading, and reloading phases. Additionally, we validated the models by using the resulting fit parameters to predict an independent set of experimental stress-strain curves from ramp-to-failure tests. Overall, the models were both successful in fitting the experiments and predicting the validation data. However, the results did not strongly favor one mechanism over the other. As a result, to distinguish between plastic deformation and damage, different experimental protocols will be needed. Nevertheless, these findings suggest the potential of RIE as a comprehensive framework for studying tendon inelastic behaviors.
Collapse
Affiliation(s)
- Babak Safa
- Department of Mechanical Engineering, Department of Biomedical Engineering, University of Delaware, Newark, Delaware 19716
| | - Andrea Lee
- Department of Biomedical Engineering, University of Delaware, Newark, Delaware 19716
| | - Michael H Santare
- ASME Fellow, Department of Mechanical Engineering, Department of Biomedical Engineering, University of Delaware Newark, Delaware 19716
| | - Dawn M Elliott
- ASME Fellow, Department of Biomedical Engineering, Department of Mechanical Engineering, University of Delaware Newark, Delaware 19716
| |
Collapse
|
22
|
Safa BN, Santare MH, Elliott DM. A Reactive Inelasticity Theoretical Framework for Modeling Viscoelasticity, Plastic Deformation, and Damage in Fibrous Soft Tissue. J Biomech Eng 2019; 141:021005. [PMID: 30267056 PMCID: PMC6298536 DOI: 10.1115/1.4041575] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2018] [Revised: 09/18/2018] [Indexed: 12/12/2022]
Abstract
Fibrous soft tissues are biopolymeric materials that are made of extracellular proteins, such as different types of collagen and proteoglycans, and have a high water content. These tissues have nonlinear, anisotropic, and inelastic mechanical behaviors that are often categorized into viscoelastic behavior, plastic deformation, and damage. While tissue's elastic and viscoelastic mechanical properties have been measured for decades, there is no comprehensive theoretical framework for modeling inelastic behaviors of these tissues that is based on their structure. To model the three major inelastic mechanical behaviors of tissue's fibrous matrix, we formulated a structurally inspired continuum mechanics framework based on the energy of molecular bonds that break and reform in response to external loading (reactive bonds). In this framework, we employed the theory of internal state variables (ISV) and kinetics of molecular bonds. The number fraction of bonds, their reference deformation gradient, and damage parameter were used as state variables that allowed for consistent modeling of all three of the inelastic behaviors of tissue by using the same sets of constitutive relations. Several numerical examples are provided that address practical problems in tissue mechanics, including the difference between plastic deformation and damage. This model can be used to identify relationships between tissue's mechanical response to external loading and its biopolymeric structure.
Collapse
Affiliation(s)
- Babak N. Safa
- Mem. ASME
Department of Mechanical Engineering,
University of Delaware,
Newark, DE 19716;
Department of Biomedical Engineering,
University of Delaware,
Newark, DE 19716
e-mail:
| | - Michael H. Santare
- Fellow ASME
Department of Mechanical Engineering,
University of Delaware,
Newark, DE 19716;
Department of Biomedical Engineering,
University of Delaware,
Newark, DE 19716
e-mail:
| | - Dawn M. Elliott
- Fellow ASME
Department of Biomedical Engineering,
University of Delaware,
Newark, DE 19716;
Department of Mechanical Engineering,
University of Delaware,
Newark, DE 19716
e-mail:
| |
Collapse
|
23
|
Sellon JB, Azadi M, Oftadeh R, Nia HT, Ghaffari R, Grodzinsky AJ, Freeman DM. Nanoscale Poroelasticity of the Tectorial Membrane Determines Hair Bundle Deflections. PHYSICAL REVIEW LETTERS 2019; 122:028101. [PMID: 30720330 PMCID: PMC6813812 DOI: 10.1103/physrevlett.122.028101] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/26/2018] [Revised: 10/14/2018] [Indexed: 06/09/2023]
Abstract
Stereociliary imprints in the tectorial membrane (TM) have been taken as evidence that outer hair cells are sensitive to shearing displacements of the TM, which plays a key role in shaping cochlear sensitivity and frequency selectivity via resonance and traveling wave mechanisms. However, the TM is highly hydrated (97% water by weight), suggesting that the TM may be flexible even at the level of single hair cells. Here we show that nanoscale oscillatory displacements of microscale spherical probes in contact with the TM are resisted by frequency-dependent forces that are in phase with TM displacement at low and high frequencies, but are in phase with TM velocity at transition frequencies. The phase lead can be as much as a quarter of a cycle, thereby contributing to frequency selectivity and stability of cochlear amplification.
Collapse
Affiliation(s)
- Jonathan B. Sellon
- Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, USA
| | - Mojtaba Azadi
- School of Engineering, College of Science and Engineering, San Francisco State University, San Francisco, CA 94132, USA
- Center for Biomedical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139
- Department of Biological Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Ramin Oftadeh
- Center for Biomedical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139
- Department of Biological Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Hadi Tavakoli Nia
- Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA
| | - Roozbeh Ghaffari
- Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, USA
| | - Alan J. Grodzinsky
- Center for Biomedical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139
- Department of Biological Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
- Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Dennis M. Freeman
- Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, USA
- Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| |
Collapse
|
24
|
Han G, Hess C, Eriten M, Henak CR. Uncoupled poroelastic and intrinsic viscoelastic dissipation in cartilage. J Mech Behav Biomed Mater 2018; 84:28-34. [DOI: 10.1016/j.jmbbm.2018.04.024] [Citation(s) in RCA: 27] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2018] [Revised: 04/09/2018] [Accepted: 04/25/2018] [Indexed: 11/16/2022]
|
25
|
Connizzo BK, Grodzinsky AJ. Multiscale Poroviscoelastic Compressive Properties of Mouse Supraspinatus Tendons Are Altered in Young and Aged Mice. J Biomech Eng 2018; 140:2666618. [PMID: 29238818 PMCID: PMC5816244 DOI: 10.1115/1.4038745] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2017] [Revised: 12/04/2017] [Indexed: 02/02/2023]
Abstract
Rotator cuff disorders are one of the most common causes of shoulder pain and disability in the aging population but, unfortunately, the etiology is still unknown. One factor thought to contribute to the progression of disease is the external compression of the rotator cuff tendons, which can be significantly increased by age-related changes such as muscle weakness and poor posture. The objective of this study was to investigate the baseline compressive response of tendon and determine how this response is altered during maturation and aging. We did this by characterizing the compressive mechanical, viscoelastic, and poroelastic properties of young, mature, and aged mouse supraspinatus tendons using macroscale indentation testing and nanoscale high-frequency AFM-based rheology testing. Using these multiscale techniques, we found that aged tendons were stiffer than their mature counterparts and that both young and aged tendons exhibited increased hydraulic permeability and energy dissipation. We hypothesize that regional and age-related variations in collagen morphology and organization are likely responsible for changes in the multiscale compressive response as these structural parameters may affect fluid flow. Importantly, these results suggest a role for age-related changes in the progression of tendon degeneration, and we hypothesize that decreased ability to resist compressive loading via fluid pressurization may result in damage to the extracellular matrix (ECM) and ultimately tendon degeneration. These studies provide insight into the regional multiscale compressive response of tendons and indicate that altered compressive properties in aging tendons may be a major contributor to overall tendon degeneration.
Collapse
Affiliation(s)
- Brianne K. Connizzo
- Department of Biological Engineering,
Massachusetts Institute of Technology,
Cambridge, MA 02139
| | - Alan J. Grodzinsky
- Department of Biological Engineering,Massachusetts Institute of Technology,
Cambridge, MA 02139;
Center for Biomedical Engineering,Massachusetts Institute of Technology,
Cambridge, MA 02139;
Department of Electrical Engineeringand Computer Science,
Massachusetts Institute of Technology,
Cambridge, MA 02139;
Department of Mechanical Engineering,Massachusetts Institute of Technology,
Cambridge, MA 02139
e-mail:
| |
Collapse
|
26
|
Biological connective tissues exhibit viscoelastic and poroelastic behavior at different frequency regimes: Application to tendon and skin biophysics. Acta Biomater 2018; 70:249-259. [PMID: 29425716 DOI: 10.1016/j.actbio.2018.01.041] [Citation(s) in RCA: 39] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2017] [Revised: 01/28/2018] [Accepted: 01/29/2018] [Indexed: 10/18/2022]
Abstract
In this study, a poroviscoelastic finite element model (FEM) was developed and used in conjunction with an AFM-based wide-bandwidth nanorheology system to predict the frequency-dependent mechanical behavior of tendon and dermis subjected to compression via nanoindentation. The aim was to distinguish between loading rates that are dominated by either poroelasticity, viscoelasticity, or the superposition of these processes. Using spherical probe tips having different radii, the force and tip displacement were measured and the magnitude, E∗, and phase angle, ϕ, of the dynamic complex modulus were evaluated for mouse supraspinatus tendon and mouse dermis. The peak frequencies of the phase angle were associated with the characteristic time constants of poroelastic and viscoelastic material behavior. The developed FE model could predict the separate poroelastic and viscoelastic responses of these soft tissues over a 4 decade frequency range, showing good agreement with experimental results. We observed that poroelasticity was the dominant energy dissipation mechanism for mouse dermis and supraspinatus tendon at higher indentation frequencies (102 to 104 Hz) whereas viscoelasticity was typically dominant at lower frequencies (<102 Hz). These findings show the underlying mechanical behavior of biological connective tissues and give insight into the role played by these different energy dissipation mechanisms in governing the function of these tissues at nanoscale. STATEMENT OF SIGNIFICANCE Soft biological tissues exhibit complex, load- and time-dependent mechanical behavior. Evaluating their mechanical behavior requires sophisticated experimental tools and numerical models that can capture the fundamental mechanisms governing tissue function. Using an Atomic-force-microscopy-based rheology system and finite element models, the roles of the two most dominant time-dependent mechanisms (poroelasticity and viscoelasticity) that govern the dynamic loading behavior of mouse skin and tendon have been investigated. FE models were able to predict and quantify the contribution of each mechanism to the overall dynamic response and confirming the presence of these two distinct mechanisms in the mechanical response. Overall, these results provide novel insight into the viscoelastic and poroelastic properties of mouse skin and tendon and promote better understanding of the underlying origins of each mechanism.
Collapse
|
27
|
Szczesny SE, Aeppli C, David A, Mauck RL. Fatigue loading of tendon results in collagen kinking and denaturation but does not change local tissue mechanics. J Biomech 2018. [PMID: 29519673 DOI: 10.1016/j.jbiomech.2018.02.014] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
Fatigue loading is a primary cause of tendon degeneration, which is characterized by the disruption of collagen fibers and the appearance of abnormal (e.g., cartilaginous, fatty, calcified) tissue deposits. The formation of such abnormal deposits, which further weakens the tissue, suggests that resident tendon cells acquire an aberrant phenotype in response to fatigue damage and the resulting altered mechanical microenvironment. While fatigue loading produces clear changes in collagen organization and molecular denaturation, no data exist regarding the effect of fatigue on the local tissue mechanical properties. Therefore, the objective of this study was to identify changes in the local tissue stiffness of tendons after fatigue loading. We hypothesized that fatigue damage would reduce local tissue stiffness, particularly in areas with significant structural damage (e.g., collagen denaturation). We tested this hypothesis by identifying regions of local fatigue damage (i.e., collagen fiber kinking and molecular denaturation) via histologic imaging and by measuring the local tissue modulus within these regions via atomic force microscopy (AFM). Counter to our initial hypothesis, we found no change in the local tissue modulus as a consequence of fatigue loading, despite widespread fiber kinking and collagen denaturation. These data suggest that immediate changes in topography and tissue structure - but not local tissue mechanics - initiate the early changes in tendon cell phenotype as a consequence of fatigue loading that ultimately culminate in tendon degeneration.
Collapse
Affiliation(s)
- Spencer E Szczesny
- Department of Orthopaedic Surgery, University of Pennsylvania, 110 Stemmler Hall, 36th Street & Hamilton Walk, Philadelphia, PA 19104, United States; Department of Biomedical Engineering, Department of Orthopaedics and Rehabilitation, Pennsylvania State University, 205 Hallowell Building, University Park, PA 16802, United States.
| | - Céline Aeppli
- Eidgenössische Technische Hochschule, Rämistrasse 101, 8092 Zürich, Switzerland
| | - Alexander David
- Department of Bioengineering, 240 Skirkanich Hall, 210 South 33rd Street, University of Pennsylvania, Philadelphia, PA 19104, United States
| | - Robert L Mauck
- Department of Orthopaedic Surgery, University of Pennsylvania, 110 Stemmler Hall, 36th Street & Hamilton Walk, Philadelphia, PA 19104, United States; Department of Bioengineering, 240 Skirkanich Hall, 210 South 33rd Street, University of Pennsylvania, Philadelphia, PA 19104, United States; Translational Musculoskeletal Research Center, Corporal Michael J. Crescenz Veterans Affairs Medical Center, 3900 Woodland Avenue, Philadelphia, PA 19104, United States
| |
Collapse
|
28
|
Han B, Nia HT, Wang C, Chandrasekaran P, Li Q, Chery DR, Li H, Grodzinsky AJ, Han L. AFM-Nanomechanical Test: An Interdisciplinary Tool That Links the Understanding of Cartilage and Meniscus Biomechanics, Osteoarthritis Degeneration, and Tissue Engineering. ACS Biomater Sci Eng 2017; 3:2033-2049. [PMID: 31423463 PMCID: PMC6697429 DOI: 10.1021/acsbiomaterials.7b00307] [Citation(s) in RCA: 38] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Our objective is to provide an in-depth review of the recent technical advances of atomic force microscopy (AFM)-based nanomechanical tests and their contribution to a better understanding and diagnosis of osteoarthritis (OA), as well as the repair of tissues undergoing degeneration during OA progression. We first summarize a range of technical approaches for AFM-based nanoindentation, including considerations in both experimental design and data analysis. We then provide a more detailed description of two recently developed modes of AFM-nanoindentation, a high-bandwidth nanorheometer system for studying poroviscoelasticity and an immunofluorescence-guided nanomechanical mapping technique for delineating the pericellular matrix (PCM) and territorial/interterritorial matrix (T/IT-ECM) of surrounding cells in connective tissues. Next, we summarize recent applications of these approaches to three aspects of joint-related healthcare and disease: cartilage aging and OA, developmental biology and OA pathogenesis in murine models, and nanomechanics of the meniscus. These studies were performed over a hierarchy of length scales, from the molecular, cellular to the whole tissue level. The advances described here have contributed greatly to advancing the fundamental knowledge base for improved understanding, detection, and treatment of OA.
Collapse
Affiliation(s)
- Biao Han
- School of Biomedical Engineering, Science and Health Systems, Drexel University, Philadelphia, Pennsylvania 19104, United States
| | - Hadi T. Nia
- Department of Radiation Oncology, Massachusetts General Hospital Harvard Medical School, Boston, Massachusetts 02114, United States
| | - Chao Wang
- School of Biomedical Engineering, Science and Health Systems, Drexel University, Philadelphia, Pennsylvania 19104, United States
| | - Prashant Chandrasekaran
- School of Biomedical Engineering, Science and Health Systems, Drexel University, Philadelphia, Pennsylvania 19104, United States
| | - Qing Li
- School of Biomedical Engineering, Science and Health Systems, Drexel University, Philadelphia, Pennsylvania 19104, United States
| | - Daphney R. Chery
- School of Biomedical Engineering, Science and Health Systems, Drexel University, Philadelphia, Pennsylvania 19104, United States
| | - Hao Li
- College of Architecture and the Built Environment, Philadelphia University, Philadelphia, Pennsylvania 19144, United States
| | - Alan J. Grodzinsky
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, United States
- Department of Biological Engineering, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, United States
- Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, United States
| | - Lin Han
- School of Biomedical Engineering, Science and Health Systems, Drexel University, Philadelphia, Pennsylvania 19104, United States
| |
Collapse
|