Holden A, Hill AA, Buckley BT. Shape memory polymer technology in peripheral vascular embolization. Vascular 2024; 32:1137-1142. [PMID: 37218283 PMCID: PMC11488294 DOI: 10.1177/17085381231177851] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
OBJECTIVES Porous, radiolucent, shape memory polymer is a new technology available in discrete peripheral vascular embolization devices. Shape memory polymers can exist in two stable shapes; crimped for catheter delivery and expanded for vessel embolization. The expanded shape memory polymer in these new devices is hemostatic, and the porous polymeric scaffold has been shown to support tissue ingrowth and eventually bioabsorbs in preclinical animal studies. This report describes clinical experience with this novel material in vascular plug devices. METHODS a prospective, single-arm, safety study at a single center in New Zealand with longer term follow-up via retrospective imaging review. The study device was a pushable shape memory polymer vascular plug with a distal nitinol anchor coil and a proximal radiopaque marker. RESULTS Ten male patients were each implanted with a single shape memory polymer vascular plug. Three inferior mesenteric arteries and an accessory renal artery were embolized during endovascular aneurysm repair. An internal iliac artery was treated prior to the open surgical repair of aorto-iliac aneurysms. An internal iliac artery and a subclavian artery were embolized to treat/prophylactically address potential endoleaks. A profunda branch was embolized prior to tumor resection, and two testicular veins were embolized to treat varicoceles. Acute technical success of target vessel embolization was achieved in all implantation cases. Patients were followed for 30 days as part of the study, and no serious adverse events with a relationship to the study device occurred. No recurrent clinical symptoms attributable to treated vessel embolization or recanalization were documented. There was no evidence of recanalization on retrospective review of follow-up imaging through a mean of 22.2 months (range, <1-44 months) post-procedure. CONCLUSIONS Shape memory polymer vascular embolization devices were safe and effective over the follow-up period of this small safety study. Further experience and longer term follow-up will assess further applicability.
Collapse
Affiliation(s)
- Andrew Holden
- Department of Radiology, Auckland City Hospital, Auckland, New Zealand
| | - Andrew A Hill
- Department of Vascular Services, Auckland City Hospital, Auckland, New Zealand
| | - Brendan T Buckley
- Department of Radiology, Auckland City Hospital, Auckland, New Zealand
| |
Collapse
|
2
|
Smorenburg SPM, Lely RJ, Jacobs MJ, Hoksbergen AWJ. Aortic aneurysm sac filling with AneuFix injectable polymer during endovascular aneurysm repair: feasibility and safety trial study protocol. BMJ Open 2024; 14:e082380. [PMID: 39009453 PMCID: PMC11253768 DOI: 10.1136/bmjopen-2023-082380] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/22/2023] [Accepted: 06/24/2024] [Indexed: 07/17/2024] Open
Abstract
INTRODUCTION Type II endoleaks (T2ELs) following endovascular aneurysm repair (EVAR) for abdominal aortic aneurysm (AAA) can lead to aneurysm growth, compromising the stent graft seal and risking rupture. Preventing these endoleaks during EVAR involves filling the AAA sac around the stent graft to exclude the aneurysm and block any arteries causing the endoleak. This study investigates the feasibility and safety of using AneuFix, a biocompatible injectable polymer developed by TripleMed (Geleen, the Netherlands), for aneurysmal sac filling during EVAR in high-risk T2EL patients. METHODS AND ANALYSIS A feasibility, single-arm, single-centre clinical trial will initially include five patients with infrarenal AAA, eligible for EVAR, and at high risk for T2EL based on the number of patent lumbar arteries and the cross-sectional area of the aortic lumen at the level of the inferior mesenteric artery. Postevaluation by the Data Safety and Monitoring Board, the study cohort will extend to 25 patients. During EVAR and after stent graft deployment, the aneurysm sac is filled with AneuFix polymer using a filling sheath positioned parallel to the contralateral limb with the tip inside the aneurysm sac. Primary outcome is technical success (successful AAA sac filling). The secondary outcomes include clinical success at 6 and 12 months (occurrence of T2ELs and AAA growth assessed with CT angiography), intraoperative and perioperative complications, all endoleaks, adverse events, re-interventions, aneurysm rupture and patient survival. ETHICS AND DISSEMINATION This trial was approved by the Dutch Authorities (Central Committee on Research Involving Human Subjects, IGJ), Amsterdam University Medical Centre Ethical Commission, and adheres to the Declaration of Helsinki and European Medical Device Regulation. Results will be shared at (inter)national conferences and in peer-reviewed journals. TRIAL REGISTRATION NUMBER NCT04307992.
Collapse
Affiliation(s)
- Stefan P M Smorenburg
- Department of Surgery, Amsterdam UMC location Vrije Universiteit, Amsterdam, The Netherlands
- Amsterdam Cardiovascular Sciences, Amsterdam, The Netherlands
| | - Rutger J Lely
- Amsterdam Cardiovascular Sciences, Amsterdam, The Netherlands
- Department of Radiology, Amsterdam UMC location Vrije Universiteit, Amsterdam, The Netherlands
| | - Michael J Jacobs
- Department of Vascular Surgery, European Vascular Centre Maastricht-Aachen, Maastricht University Medical Centre, Maastricht, The Netherlands
| | - Arjan W J Hoksbergen
- Department of Surgery, Amsterdam UMC location Vrije Universiteit, Amsterdam, The Netherlands
- Amsterdam Cardiovascular Sciences, Amsterdam, The Netherlands
| |
Collapse
|
3
|
Abdelrahman MK, Wagner RJ, Kalairaj MS, Zadan M, Kim MH, Jang LK, Wang S, Javed M, Dana A, Singh KA, Hargett SE, Gaharwar AK, Majidi C, Vernerey FJ, Ware TH. Material assembly from collective action of shape-changing polymers. NATURE MATERIALS 2024; 23:281-289. [PMID: 38177377 DOI: 10.1038/s41563-023-01761-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/15/2022] [Accepted: 11/14/2023] [Indexed: 01/06/2024]
Abstract
Some animals form transient, responsive and solid-like ensembles through dynamic structural interactions. These ensembles demonstrate emergent responses such as spontaneous self-assembly, which are difficult to achieve in synthetic soft matter. Here we use shape-morphing units comprising responsive polymers to create solids that self-assemble, modulate their volume and disassemble on demand. The ensemble is composed of a responsive hydrogel, liquid crystal elastomer or semicrystalline polymer ribbons that reversibly bend or twist. The dispersions of these ribbons mechanically interlock, inducing reversible aggregation. The aggregated liquid crystal elastomer ribbons have a 12-fold increase in the yield stress compared with cooled dispersion and contract by 34% on heating. Ribbon type, concentration and shape dictate the aggregation and govern the global mechanical properties of the solid that forms. Coating liquid crystal elastomer ribbons with a liquid metal begets photoresponsive and electrically conductive aggregates, whereas seeding cells on hydrogel ribbons enables self-assembling three-dimensional scaffolds, providing a versatile platform for the design of dynamic materials.
Collapse
Affiliation(s)
- Mustafa K Abdelrahman
- Department of Materials Science and Engineering, Texas A&M University, College Station, TX, USA
| | - Robert J Wagner
- Mechanical Engineering Department, Materials Science and Engineering Program, University of Colorado, Boulder, CO, USA
- Department of Mechanical and Aerospace Engineering, Cornell University, Ithaca, NY, USA
| | | | - Mason Zadan
- Department of Mechanical Engineering, Carnegie Mellon University, Pittsburgh, PA, USA
| | - Min Hee Kim
- Department of Biomedical Engineering, Texas A&M University, College Station, TX, USA
| | - Lindy K Jang
- Department of Biomedical Engineering, Texas A&M University, College Station, TX, USA
- Materials Engineering Division, Lawrence Livermore National Laboratory, Livermore, CA, USA
| | - Suitu Wang
- Department of Materials Science and Engineering, Texas A&M University, College Station, TX, USA
| | - Mahjabeen Javed
- Department of Biomedical Engineering, Texas A&M University, College Station, TX, USA
| | - Asaf Dana
- Department of Biomedical Engineering, Texas A&M University, College Station, TX, USA
| | - Kanwar Abhay Singh
- Department of Biomedical Engineering, Texas A&M University, College Station, TX, USA
| | - Sarah E Hargett
- Department of Biomedical Engineering, Texas A&M University, College Station, TX, USA
| | - Akhilesh K Gaharwar
- Department of Biomedical Engineering, Texas A&M University, College Station, TX, USA
| | - Carmel Majidi
- Department of Mechanical Engineering, Carnegie Mellon University, Pittsburgh, PA, USA
| | - Franck J Vernerey
- Mechanical Engineering Department, Materials Science and Engineering Program, University of Colorado, Boulder, CO, USA
| | - Taylor H Ware
- Department of Materials Science and Engineering, Texas A&M University, College Station, TX, USA.
- Department of Biomedical Engineering, Texas A&M University, College Station, TX, USA.
| |
Collapse
|
4
|
Touchet TJ, Brinson B, Jones M, Byju A, Fletcher G, Hasan SM, Nash LD, Maitland DJ. Development of Biopsy Tract Sealants Based on Shape Memory Polymer Foams. BIOMEDICAL MATERIALS & DEVICES (NEW YORK, N.Y.) 2023; 1:853-860. [PMID: 38130883 PMCID: PMC10732340 DOI: 10.1007/s44174-023-00064-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/12/2022] [Accepted: 01/24/2023] [Indexed: 12/23/2023]
Abstract
Lung biopsies are often used to aid in the diagnosis of cancers. However, the procedure carries the dual risk of air (pneumothorax) or blood (hemothorax) filling the pleural cavity, increasing the risk of a collapsed lung and chest intubation. This work demonstrates the effectiveness of a polyurethane-based shape memory polymer foam as a biopsy tract sealant. The impact of diameter, length, pore size, and shape memory effect was evaluated to determine the ideal device design for tract sealing. Characterization in an in vitro benchtop lung model identified that diameter had the largest influence on sealing efficacy, while the length of the device had little to no impact. Finally, evaluation of deployment force demonstrated that devices fabricated from the shape memory polymer foams were easier to deploy than elastic foams. Following characterization, down-selected device designs were combined with radiopaque markers for use in image-guided based procedures. Furthermore, the introduction of the markers or sterilization did not impact the ability of the devices to seal the biopsy tract and led to a decrease in the deployment force. Overall, these results demonstrate the potential for polyurethane-based shape memory foam devices to serve as biopsy tract sealant devices that aim to reduce complications, such as pneumothorax, from occurring.
Collapse
Affiliation(s)
- Tyler J. Touchet
- Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843
| | - Braeden Brinson
- Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843
| | - McKenzie Jones
- Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843
| | - Achu Byju
- Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843
| | - Grace Fletcher
- Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843
| | | | | | - Duncan J. Maitland
- Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843
- Shape Memory Medical, Inc., Santa Clara, CA 95054, USA
| |
Collapse
|
5
|
Vakil AU, Petryk NM, Du C, Howes B, Stinfort D, Serinelli S, Gitto L, Ramezani M, Beaman HT, Monroe MBB. In vitro and in vivo degradation correlations for polyurethane foams with tunable degradation rates. J Biomed Mater Res A 2023; 111:580-595. [PMID: 36752708 DOI: 10.1002/jbm.a.37504] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2022] [Revised: 12/19/2022] [Accepted: 01/13/2023] [Indexed: 02/09/2023]
Abstract
Polyurethane foams present a tunable biomaterial platform with potential for use in a range of regenerative medicine applications. Achieving a balance between scaffold degradation rates and tissue ingrowth is vital for successful wound healing, and significant in vivo testing is required to understand these processes. Vigorous in vitro testing can minimize the number of animals that are required to gather reliable data; however, it is difficult to accurately select in vitro degradation conditions that can effectively mimic in vivo results. To that end, we performed a comprehensive in vitro assessment of the degradation of porous shape memory polyurethane foams with tunable degradation rates using varying concentrations of hydrogen peroxide to identify the medium that closely mimics measured in vivo degradation rates. Material degradation was studied over 12 weeks in vitro in 1%, 2%, or 3% hydrogen peroxide and in vivo in subcutaneous pockets in Sprague Dawley rats. We found that the in vitro degradation conditions that best predicted in vivo degradation rates varied based on the number of mechanisms by which the polymer degraded and the polymer hydrophilicity. Namely, more hydrophilic materials that degrade by both hydrolysis and oxidation require lower concentrations of hydrogen peroxide (1%) to mimic in vivo rates, while more hydrophobic scaffolds that degrade by oxidation alone require higher concentrations of hydrogen peroxide (3%) to model in vivo degradation. This information can be used to rationally select in vitro degradation conditions that accurately identify in vivo degradation rates prior to characterization in an animal model.
Collapse
Affiliation(s)
- Anand Utpal Vakil
- Department of Biomedical and Chemical Engineering and BioInspired Syracuse, Institute for Material and Living Systems, Syracuse University, Syracuse, New York, USA
| | - Natalie Marie Petryk
- Department of Biomedical and Chemical Engineering and BioInspired Syracuse, Institute for Material and Living Systems, Syracuse University, Syracuse, New York, USA
| | - Changling Du
- Department of Biomedical and Chemical Engineering and BioInspired Syracuse, Institute for Material and Living Systems, Syracuse University, Syracuse, New York, USA
| | - Bryanna Howes
- Department of Chemistry, Le Moyne College, Syracuse, New York, USA
| | | | | | - Lorenzo Gitto
- SUNY Upstate Medical University, Syracuse, New York, USA
| | - Maryam Ramezani
- Department of Biomedical and Chemical Engineering and BioInspired Syracuse, Institute for Material and Living Systems, Syracuse University, Syracuse, New York, USA
| | - Henry T Beaman
- Department of Biomedical and Chemical Engineering and BioInspired Syracuse, Institute for Material and Living Systems, Syracuse University, Syracuse, New York, USA
| | - Mary Beth Browning Monroe
- Department of Biomedical and Chemical Engineering and BioInspired Syracuse, Institute for Material and Living Systems, Syracuse University, Syracuse, New York, USA
| |
Collapse
|
6
|
Masuda S, Tsukiyama T, Makazu M, Jinushi R, Koizumi K, Nishino T, Shionoya K, Kimura K, Sumida C, Kubota J, Ichita C, Sasaki A, Kobayashi M, Kako M, Uojima H. A case of unsuccessful obliteration of percutaneous transhepatic gastric varices using the IMPEDE embolization plug. Clin Case Rep 2023; 11:e07323. [PMID: 37180327 PMCID: PMC10167619 DOI: 10.1002/ccr3.7323] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2023] [Revised: 03/31/2023] [Accepted: 04/23/2023] [Indexed: 05/16/2023] Open
Abstract
Key Clinical Message Embolization with IMPEDE embolization plug cannot be confirmed on site. Therefore, we propose that the diameter of the device selected be up to 50% larger than the vein diameter to prevent embolization failure and recanalization. Abstract Balloon-occluded retrograde transvenous obliteration and percutaneous transhepatic obliteration (PTO) are performed for treating sporadic gastric varices. IMPEDE embolization plug has been recently developed for these procedures; however, no studies have reported its use. This is the first report on its use in PTO of gastric varices.
Collapse
Affiliation(s)
- Sakue Masuda
- Department of Gastroenterology Medicine CenterShonan Kamakura General HospitalKamakuraJapan
| | - Toshitaka Tsukiyama
- Department of Interventional Radiology CenterShonan Kamakura General HospitalKamakuraJapan
| | - Makomo Makazu
- Department of Gastroenterology Medicine CenterShonan Kamakura General HospitalKamakuraJapan
| | - Ryuhei Jinushi
- Department of Gastroenterology Medicine CenterShonan Kamakura General HospitalKamakuraJapan
| | - Kazuya Koizumi
- Department of Gastroenterology Medicine CenterShonan Kamakura General HospitalKamakuraJapan
| | - Takashi Nishino
- Department of Gastroenterology Medicine CenterShonan Kamakura General HospitalKamakuraJapan
| | - Kento Shionoya
- Department of Gastroenterology Medicine CenterShonan Kamakura General HospitalKamakuraJapan
| | - Karen Kimura
- Department of Gastroenterology Medicine CenterShonan Kamakura General HospitalKamakuraJapan
| | - Chihiro Sumida
- Department of Gastroenterology Medicine CenterShonan Kamakura General HospitalKamakuraJapan
| | - Jun Kubota
- Department of Gastroenterology Medicine CenterShonan Kamakura General HospitalKamakuraJapan
| | - Chikamasa Ichita
- Department of Gastroenterology Medicine CenterShonan Kamakura General HospitalKamakuraJapan
| | - Akiko Sasaki
- Department of Gastroenterology Medicine CenterShonan Kamakura General HospitalKamakuraJapan
| | - Masahiro Kobayashi
- Department of Gastroenterology Medicine CenterShonan Kamakura General HospitalKamakuraJapan
| | - Makoto Kako
- Department of Gastroenterology Medicine CenterShonan Kamakura General HospitalKamakuraJapan
| | - Haruki Uojima
- Department of Gastroenterology, Internal MedicineKitasato University School of MedicineSagamiharaJapan
| |
Collapse
|
7
|
Sheikh A, Abourehab MAS, Kesharwani P. The clinical significance of 4D printing. Drug Discov Today 2023; 28:103391. [PMID: 36195204 DOI: 10.1016/j.drudis.2022.103391] [Citation(s) in RCA: 16] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2022] [Revised: 08/11/2022] [Accepted: 09/28/2022] [Indexed: 02/02/2023]
Abstract
4D printing is the next step on from 3D printing involving the fourth dimension of 'time'. The programmed 4D-printed objects are capable of changing their shape in response to external stimuli, such as light, heat, or water, differentiating them from 3D-printed static objects. This technique promises new possibilities for cancer treatment, drug delivery, stent development, and tissue engineering. In this review, we focus on the development of 4D-printed objects, their clinical use, and the possibility of 5D printing, which could revolutionize the fields of biomedical engineering and drug delivery.
Collapse
Affiliation(s)
- Afsana Sheikh
- Department of Pharmaceutics, School of Pharmaceutical Education and Research, Jamia Hamdard, New Delhi 110062, India
| | - Mohammed A S Abourehab
- Department of Pharmaceutics, College of Pharmacy, Umm Al-Qura University, Makkah 21955, Saudi Arabia; Department of Pharmaceutics and Industrial Pharmacy, College of Pharmacy, Minia University, Minia 61519, Egypt
| | - Prashant Kesharwani
- Department of Pharmaceutics, School of Pharmaceutical Education and Research, Jamia Hamdard, New Delhi 110062, India.
| |
Collapse
|
8
|
Zhao W, Yue C, Liu L, Liu Y, Leng J. Research Progress of Shape Memory Polymer and 4D Printing in Biomedical Application. Adv Healthc Mater 2022:e2201975. [PMID: 36520058 DOI: 10.1002/adhm.202201975] [Citation(s) in RCA: 25] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2022] [Revised: 11/06/2022] [Indexed: 12/23/2022]
Abstract
As a kind of smart material, shape memory polymer (SMP) shows great application potential in the biomedical field. Compared with traditional metal-based medical devices, SMP-based devices have the following characteristics: 1) The adaptive ability allows the biomedical device to better match the surrounding tissue after being implanted into the body by minimally invasive implantation; 2) it has better biocompatibility and adjustable biodegradability; 3) mechanical properties can be regulated in a large range to better match with the surrounding tissue. 4D printing technology is a comprehensive technology based on smart materials and 3D printing, which has great application value in the biomedical field. 4D printing technology breaks through the technical bottleneck of personalized customization and provides a new opportunity for the further development of the biomedical field. This paper summarizes the application of SMP and 4D printing technology in the field of bone tissue scaffolds, tracheal scaffolds, and drug release, etc. Moreover, this paper analyzes the existing problems and prospects, hoping to provide a preliminary discussion and useful reference for the application of SMP in biomedical engineering.
Collapse
Affiliation(s)
- Wei Zhao
- Department of Astronautical Science and Mechanics, Harbin Institute of Technology (HIT), P.O. Box 301, No. 92 West Dazhi Street, Harbin, 150001, P. R. China
| | - Chengbin Yue
- Department of Astronautical Science and Mechanics, Harbin Institute of Technology (HIT), P.O. Box 301, No. 92 West Dazhi Street, Harbin, 150001, P. R. China
| | - Liwu Liu
- Department of Astronautical Science and Mechanics, Harbin Institute of Technology (HIT), P.O. Box 301, No. 92 West Dazhi Street, Harbin, 150001, P. R. China
| | - Yanju Liu
- Department of Astronautical Science and Mechanics, Harbin Institute of Technology (HIT), P.O. Box 301, No. 92 West Dazhi Street, Harbin, 150001, P. R. China
| | - Jinsong Leng
- Center for Composite Materials and Structures, Harbin Institute of Technology (HIT), P.O. Box 3011, No. 2 Yikuang Street, Harbin, 150080, P. R. China
| |
Collapse
|
9
|
Graul LM, Horn SJ, Nash LD, Cheung TB, Clubb FJ, Maitland DJ. Image-Based Evaluation of In Vivo Degradation for Shape-Memory Polymer Polyurethane Foam. Polymers (Basel) 2022; 14:4122. [PMID: 36236069 PMCID: PMC9571375 DOI: 10.3390/polym14194122] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2022] [Revised: 09/09/2022] [Accepted: 09/12/2022] [Indexed: 11/06/2022] Open
Abstract
Shape-memory polymer (SMP) polyurethane foams have been applied as embolic devices and implanted in multiple animal models. These materials are oxidatively degradable and it is critical to quantify and characterize the degradation for biocompatibility assessments. An image-based method using high-resolution and magnification scans of histology sections was used to estimate the mass loss of the peripheral and neurovascular embolization devices (PED, NED). Detailed analysis of foam microarchitecture (i.e., struts and membranes) was used to estimate total relative mass loss over time. PED foams implanted in porcine arteries showed a degradation rate of ~0.11% per day as evaluated at 30-, 60-, and 90-day explant timepoints. NED foams implanted in rabbit carotid elastase aneurysms showed a markedly faster rate of degradation at ~1.01% per day, with a clear difference in overall degradation between 30- and 90-day explants. Overall, membranes degraded faster than the struts. NEDs use more hydrophobic foam with a smaller pore size (~150-400 μm) compared to PED foams (~800-1200 μm). Previous in vitro studies indicated differences in the degradation of the two polymer systems, but not to the magnitude seen in vivo. Implant location, animal species, and local tissue health are among the hypothesized reasons for different degradation rates.
Collapse
Affiliation(s)
- Lance M. Graul
- Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843, USA
| | - Staci J. Horn
- Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843, USA
- Department of Veterinary Pathobiology, Texas A&M University, College Station, TX 77843, USA
| | | | - Thomas B. Cheung
- Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843, USA
| | - Fred J. Clubb
- Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843, USA
- Department of Veterinary Pathobiology, Texas A&M University, College Station, TX 77843, USA
| | - Duncan J. Maitland
- Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843, USA
- Shape Memory Medical Inc., Santa Clara, CA 95054, USA
| |
Collapse
|
10
|
Graul LM, Liu S, Maitland DJ. Theoretical error of sectional method for estimation of shape memory polyurethane foam mass loss. J Colloid Interface Sci 2022; 625:237-247. [PMID: 35716618 DOI: 10.1016/j.jcis.2022.06.045] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2021] [Revised: 06/03/2022] [Accepted: 06/09/2022] [Indexed: 11/25/2022]
Abstract
INTRODUCTION Measuring in vivo degradation for polymeric scaffolds is critical for analysis of biocompatibility. Traditionally, histology has been used to estimate mass loss in scaffolds, allowing for simultaneous evaluation of mass loss and the biologic response to the implant. Oxidatively degradable shape memory polyurethane (SMP) foams have been implemented in two vascular occlusion devices: peripheral embolization device (PED) and neurovascular embolization device (NED). This work explores the errors introduced when using histological sections to evaluate mass loss. METHODS Models of the SMP foams were created to mimic the device geometry and the tetrakaidekahedral structure of the foam pore. These models were degraded in Blender for a wide range of possible degradation amounts and the mass loss was estimated using m sections. RESULTS As the number of sections (m) used to estimate mass loss for a volume increased the sampling error decreased and beyond m = 5, the decrease in error was insignificant. NED population and sampling errors were higher than for PED scenarios. When m ≥ 5, the averaged sampling error was below 1.5% for NED and 1% for PED scenarios. DISCUSSION/CONCLUSION This study establishes a baseline sampling error for estimating randomly degraded porous scaffolds using a sectional method. Device geometry and the stage of mass loss influence the sampling error. Future studies will use non-random degradation to further investigate in vivo mass loss scenarios.
Collapse
Affiliation(s)
- Lance M Graul
- Department of Biomedical Engineering, Texas A&M University, College Station, TX, United States
| | - Shuling Liu
- Department of Statistics, Texas A&M University, College Station, TX, United States
| | - Duncan J Maitland
- Department of Biomedical Engineering, Texas A&M University, College Station, TX, United States.
| |
Collapse
|
11
|
Luo Y, Ma Y, Chen Z, Gao Y, Zhou Y, Liu X, Liu X, Gao X, Li Z, Liu C, Leo HL, Yu H, Guo Q. Shape-Anisotropic Microembolics Generated by Microfluidic Synthesis for Transarterial Embolization Treatment. Adv Healthc Mater 2022; 11:e2102281. [PMID: 35106963 DOI: 10.1002/adhm.202102281] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2021] [Revised: 12/29/2021] [Indexed: 11/11/2022]
Abstract
Particulate embolic agents with calibrated sizes, which employ interventional procedures to achieve endovascular embolization, have recently attracted tremendous interest in therapeutic embolotherapies for a wide plethora of diseases. However, the particulate shape effect, which may play a critical role in embolization performances, has been rarely investigated. Here, polyvinyl alcohol (PVA)-based shape-anisotropic microembolics are developed using a facile droplet-based microfluidic fabrication method via heat-accelerated PVA-glutaraldehyde crosslinking reaction at a mild temperature of 38 ° C. Precise geometrical controls of the microembolics are achieved with a nearly capsule shape through regulating surfactant concentration and flow rate ratio between dispersed phase and continuous phase in the microfluidics. Two specific models are employed, i.e., in vitro decellularized rabbit liver embolization model and in vivo rabbit ear embolization model, to systematically evaluate the embolization behaviors of the nonspherical microembolics. Compared to microspheres of the same volume, the elongated microembolics demonstrated advantageous endovascular navigation capability, penetration depth and embolization stability due to their comparatively smaller radial diameter and their central cylindrical part providing larger contact area with distal vessels. Such nonspherical microembolics present a promising platform to apply shape anisotropy to achieve distinctive therapeutic effects for endovascular treatments.
Collapse
Affiliation(s)
- Yucheng Luo
- Shenzhen Key Laboratory of Smart Healthcare Engineering Department of Biomedical Engineering Southern University of Science and Technology Shenzhen Guangdong 518055 China
| | - Yutao Ma
- Shenzhen Key Laboratory of Smart Healthcare Engineering Department of Biomedical Engineering Southern University of Science and Technology Shenzhen Guangdong 518055 China
| | - Zijian Chen
- Shenzhen Key Laboratory of Smart Healthcare Engineering Department of Biomedical Engineering Southern University of Science and Technology Shenzhen Guangdong 518055 China
- Department of Biomedical Engineering National University of Singapore Engineering Drive 3, Engineering Block 4, #04‐08 Singapore 117583 Singapore
| | - Yanan Gao
- Shenzhen Key Laboratory of Smart Healthcare Engineering Department of Biomedical Engineering Southern University of Science and Technology Shenzhen Guangdong 518055 China
| | - Yuping Zhou
- Shenzhen Key Laboratory of Smart Healthcare Engineering Department of Biomedical Engineering Southern University of Science and Technology Shenzhen Guangdong 518055 China
| | - Xiaoya Liu
- Shenzhen Key Laboratory of Smart Healthcare Engineering Department of Biomedical Engineering Southern University of Science and Technology Shenzhen Guangdong 518055 China
| | - Xuezhe Liu
- Shenzhen Key Laboratory of Smart Healthcare Engineering Department of Biomedical Engineering Southern University of Science and Technology Shenzhen Guangdong 518055 China
| | - Xu Gao
- Shenzhen Key Laboratory of Smart Healthcare Engineering Department of Biomedical Engineering Southern University of Science and Technology Shenzhen Guangdong 518055 China
| | - Zhihua Li
- Shenzhen Key Laboratory of Smart Healthcare Engineering Department of Biomedical Engineering Southern University of Science and Technology Shenzhen Guangdong 518055 China
| | - Chuang Liu
- Cryo‐EM Center Southern University of Science and Technology Shenzhen Guangdong 518055 China
| | - Hwa Liang Leo
- Department of Biomedical Engineering National University of Singapore Engineering Drive 3, Engineering Block 4, #04‐08 Singapore 117583 Singapore
| | - Hanry Yu
- Mechanobiology Institute National University of Singapore Singapore 117411 Singapore
- Institute of Bioengineering and Nanotechnology Agency for Science Technology and Research Singapore 138669 Singapore
- Department of Physiology Yong Loo Lin School of Medicine National University of Singapore Singapore 117593 Singapore
- Singapore‐MIT Alliance for Research and Technology Singapore 138602 Singapore
| | - Qiongyu Guo
- Shenzhen Key Laboratory of Smart Healthcare Engineering Department of Biomedical Engineering Southern University of Science and Technology Shenzhen Guangdong 518055 China
| |
Collapse
|
12
|
Beaman HT, Shepherd E, Satalin J, Blair S, Ramcharran H, Serinelli S, Gitto L, Dong KS, Fikhman D, Nieman G, Schauer SG, Monroe MBB. Hemostatic shape memory polymer foams with improved survival in a lethal traumatic hemorrhage model. Acta Biomater 2022; 137:112-123. [PMID: 34655799 DOI: 10.1016/j.actbio.2021.10.005] [Citation(s) in RCA: 33] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2021] [Revised: 09/30/2021] [Accepted: 10/05/2021] [Indexed: 11/01/2022]
Abstract
Although there are many hemostatic agents available for use on the battlefield, uncontrolled hemorrhage is still the primary cause of preventable death. Current hemostatic dressings include QuikClot® Combat Gauze (QCCG) and XStat®, which have inadequate success in reducing mortality. To address this need, a new hemostatic material was developed using shape memory polymer (SMP) foams, which demonstrate biocompatibility, rapid clotting, and shape recovery to fill the wound site. SMP foam hemostatic efficacy was examined in a lethal, noncompressible porcine liver injury model over 6 h following injury. Wounds were packed with SMP foams, XStat, or QCCG and compared in terms of time to bleeding cessation, total blood loss, and animal survival. The hemostatic material properties and in vitro blood interactions were also characterized. SMP foams decreased blood loss and active bleeding time in comparison with XStat and QCCG. Most importantly, SMP foams increased the 6 h survival rate by 50% and 37% (vs. XStat and QCCG, respectively) with significant increases in survival times. Based upon in vitro characterizations, this result is attributed to the low stiffness and shape filling capabilities of SMP foams. This study demonstrates that SMP foams have promise for improving upon current clinically available hemostatic dressings and that hemostatic material properties are important to consider in designing devices for noncompressible bleeding control. STATEMENT OF SIGNIFICANCE: Uncontrolled hemorrhage is the leading cause of preventable death on the battlefield, and it accounts for approximately 1.5 million deaths each year. New biomaterials are required for improved hemorrhage control, particularly in noncompressible wounds in the torso. Here, we compared shape memory polymer (SMP) foams with two clinical dressings, QuikClot Combat Gauze and XStat, in a pig model of lethal liver injury. SMP foam treatment reduced bleeding times and blood loss and significantly improved animal survival. After further material characterization, we determined that the improved outcomes with SMP foams are likely due to their low stiffness and controlled shape change after implantation, which enabled their delivery to the liver injuries without inducing further wound tearing. Overall, SMP foams provide a promising option for hemorrhage control.
Collapse
|
13
|
Vakil AU, Petryk NM, Shepherd E, Monroe MBB. Biostable Shape Memory Polymer Foams for Smart Biomaterial Applications. Polymers (Basel) 2021; 13:polym13234084. [PMID: 34883587 PMCID: PMC8658902 DOI: 10.3390/polym13234084] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2021] [Revised: 11/15/2021] [Accepted: 11/17/2021] [Indexed: 11/16/2022] Open
Abstract
Polyurethane foams provide a wide range of applications as a biomaterial system due to the ability to tune their physical, chemical, and biological properties to meet the requirements of the intended applications. Another key parameter that determines the usability of this biomaterial is its degradability under body conditions. Several current approaches focus on slowing the degradation rate for applications that require the implant to be present for a longer time frame (over 100 days). Here, biostable shape memory polymer (SMP) foams were synthesized with added ether-containing monomers to tune the degradation rates. The physical, thermal and shape memory properties of these foams were characterized along with their cytocompatibility and blood interactions. Degradation profiles were assessed in vitro in oxidative (3% H2O2; real-time) and hydrolytic media (0.1 M NaOH; accelerated) at 37 °C. The resulting foams had tunable degradation rates, with up 15% mass remaining after 108 days, and controlled erosion profiles. These easy-to-use, shape-filling SMP foams have the potential for various biomaterial applications where longer-term stability without the need for implant removal is desired.
Collapse
|
14
|
Experimental and computational analysis of a pharmaceutical-grade shape memory polymer applied to the development of gastroretentive drug delivery systems. J Mech Behav Biomed Mater 2021; 124:104814. [PMID: 34534845 DOI: 10.1016/j.jmbbm.2021.104814] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/24/2020] [Revised: 08/10/2021] [Accepted: 09/03/2021] [Indexed: 11/23/2022]
Abstract
The present paper aims at developing an integrated experimental/computational approach towards the design of shape memory devices fabricated by hot-processing with potential for use as gastroretentive drug delivery systems (DDSs) and for personalized therapy if 4D printing is involved. The approach was tested on a plasticized poly(vinyl alcohol) (PVA) of pharmaceutical grade, with a glass transition temperature close to that of the human body (i.e., 37 °C). A comprehensive experimental analysis was conducted in order to fully characterize the PVA thermo-mechanical response as well as to provide the necessary data to calibrate and validate the numerical predictions, based on a thermo-viscoelastic constitutive model, implemented within a finite element framework. Particularly, a thorough thermal, mechanical, and shape memory characterization under different testing conditions and on different sample geometries was first performed. Then, a prototype consisting of an S-shaped device was fabricated, deformed in a temporary compact configuration and tested. Simulation results were compared with the results obtained from shape memory experiments carried out on the prototype. The proposed approach provided useful results and recommendations for the design of PVA-based shape memory DDSs.
Collapse
|
15
|
Herting SM, Monroe MBB, Weems AC, Briggs ST, Fletcher GK, Blair SE, Hatch CJ, Maitland DJ. In vitro cytocompatibility testing of oxidative degradation products. J BIOACT COMPAT POL 2021. [DOI: 10.1177/08839115211003115] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Implantable medical devices must undergo thorough evaluation to ensure safety and efficacy before use in humans. If a device is designed to degrade, it is critical to understand the rate of degradation and the degradation products that will be released. Oxidative degradation is typically modeled in vitro by immersing materials or devices in hydrogen peroxide, which can limit further analysis of degradation products in many cases. Here we demonstrate a novel approach for testing the cytocompatibility of degradation products for oxidatively-degradable biomaterials where the materials are exposed to hydrogen peroxide, and then catalase enzyme is used to convert the hydrogen peroxide to water and oxygen so that the resulting aqueous solution can be added to cell culture media. To validate our results, expected degradation products are also synthesized then added to cell culture media. We used these methods to evaluate the cytocompatibility of degradation products from an oxidatively-degradable shape memory polyurethane designed in our lab and found that the degradation of these polymers is unlikely to cause a cytotoxic response in vivo based on the guidance provided by ISO 10993-5. These methods may also be applicable to other biocompatibility tests such as tests for mutagenicity or systemic toxicity, and evaluations of cell proliferation, migration, or gene and protein expression.
Collapse
Affiliation(s)
- Scott M Herting
- Department of Biomedical Engineering, Texas A&M University, College Station, TX, USA
| | - Mary Beth B Monroe
- Department of Biomedical Engineering, Texas A&M University, College Station, TX, USA
| | - Andrew C Weems
- Department of Biomedical Engineering, Texas A&M University, College Station, TX, USA
| | - Sam T Briggs
- Department of Biomedical Engineering, Texas A&M University, College Station, TX, USA
| | - Grace K Fletcher
- Department of Biomedical Engineering, Texas A&M University, College Station, TX, USA
| | - Samuel E Blair
- Department of Biomedical Engineering, Texas A&M University, College Station, TX, USA
| | - Christopher J Hatch
- Department of Biomedical Engineering, Texas A&M University, College Station, TX, USA
| | - Duncan J Maitland
- Department of Biomedical Engineering, Texas A&M University, College Station, TX, USA
| |
Collapse
|
16
|
Morgan RA, Loftus I, Ratnam L, Das R, Mailli L, Hamady MS, Lobotesis K. Clinical experience with a shape memory polymer peripheral vascular embolisation plug: a case series. CVIR Endovasc 2021; 4:29. [PMID: 33687582 PMCID: PMC7943681 DOI: 10.1186/s42155-021-00214-w] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2021] [Accepted: 02/23/2021] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Shape memory polymers are materials that are manufactured in a certain shape, can be stored in a temporary deformed shape, and then return to - or remember - their original shape upon exposure to external stimuli such as temperature and moisture. This property lends itself to application in endovascular medical devices. Peripheral vasculature embolisation devices incorporating this novel technology have become commercially available and this case series, where the data were collected as part of a post market registry, outlines initial clinical experience with these novel devices. RESULTS Eight cases are described in this series. The disease state/conditions for which embolisation was indicated were right common iliac artery aneurysms (n = 3), a type II endoleak into the thoracic aorta following thoracic endovascular aneurysm repair (n = 1), a left inferior gluteal artery aneurysm (n = 1), left internal iliac artery aneurysms (n = 2), and a case of splenomegaly, where splenectomy was planned after the embolisation procedure (n = 1). Target arteries were 5-10 mm in diameter. In each case, at least one IMPEDE Embolization Plug (IMP-Device) of an appropriate diameter was used. All procedures were technically successful and target vessel thrombosis was achieved in all cases. Follow-up imaging available during the 45-90-day data collection timeframe showed sustained vessel occlusion. This case series includes examples of situations commonly encountered when embolising the peripheral vasculature, namely, the use of one or multiple devices in a single vessel and in combination with the use of other embolic devices (e.g., microcoils, gelatin sponge, and PVA particles) in the same case. There were no adverse events related to the specific use of the device. CONCLUSIONS This small series illustrates the safety and efficacy of this novel sponge-based embolic device for the embolisation of small and medium sized arteries and further experience will demonstrate the utility of the shape memory polymer devices.
Collapse
Affiliation(s)
- Robert A Morgan
- Department of Radiology, St. George's University Hospitals NHS Foundation Trust, London, GB, UK.
| | - Ian Loftus
- Vascular Institute, St. George's Healthcare NHS Trust, London, GB, UK
| | - Lakshmi Ratnam
- Department of Radiology, St. George's University Hospitals NHS Foundation Trust, London, GB, UK
| | - Raj Das
- Department of Radiology, St. George's University Hospitals NHS Foundation Trust, London, GB, UK
| | - Leto Mailli
- Interventional Radiology, Guy's and St Thomas' NHS Foundation Trust, London, GB, UK
| | - Mohamad S Hamady
- Interventional Radiology, Imperial College-London-St. Mary's Campus, London, GB, UK
| | | |
Collapse
|
17
|
Castellano D, Boghi A, Di Maggio L, Rapellino A, Savio D. Shape memory polymer ovarian vein embolisation in a patient with nickel allergy. CVIR Endovasc 2021; 4:25. [PMID: 33655366 PMCID: PMC7925783 DOI: 10.1186/s42155-021-00212-y] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2021] [Accepted: 02/16/2021] [Indexed: 11/10/2022] Open
Abstract
Background Ovarian vein embolization in pelvic varicocele is usually obtained using nitinol coils. These devices can not be used in patients with proven nickel allergy. Case presentation Shape memory polymer is a new embolic material available to interventionalists. A patient presented with pelvic congestion syndrome requiring embolisation of the left ovarian vein. The target vessel consisted of two twisted branches, each 5–6 mm in diameter. The patient also had a known allergy to nickel. Considering the anatomy and allergy status, embolisation with polyurethane shape memory polymer vascular plugs was considered a good case strategy. The embolisation procedure was technically successful with the deployment of two shape memory polymer plugs into each of the two left ovarian vein branches. Follow-up magnetic resonance imaging at 4 months showed sustained occlusion of the treated vessels and the patient showed no signs of allergy to the implanted material. Conclusions In conclusion, our case presented an opportunity to utilise a new embolic material and achieve a good outcome in a patient with an allergy that may have resulted in complications when using metallic implants.
Collapse
Affiliation(s)
- Davide Castellano
- Department of Interventional Radiology and Neuroradiology, San Giovanni Bosco Hospital, Piazza del Donatore di Sangue, 3, 10154, Turin, Italy.
| | - Andrea Boghi
- Department of Interventional Radiology and Neuroradiology, San Giovanni Bosco Hospital, Piazza del Donatore di Sangue, 3, 10154, Turin, Italy
| | - Luca Di Maggio
- Department of Interventional Radiology and Neuroradiology, San Giovanni Bosco Hospital, Piazza del Donatore di Sangue, 3, 10154, Turin, Italy
| | - Alessandro Rapellino
- Department of Interventional Radiology and Neuroradiology, San Giovanni Bosco Hospital, Piazza del Donatore di Sangue, 3, 10154, Turin, Italy
| | - Daniele Savio
- Department of Interventional Radiology and Neuroradiology, San Giovanni Bosco Hospital, Piazza del Donatore di Sangue, 3, 10154, Turin, Italy
| |
Collapse
|
18
|
Jansen AJS, van Schaik PM, Martens JM, Reijnen MMPJ. Embolization of the false lumen using IMPEDE-FX embolization plugs as part of treatment of an infrarenal post-dissection aneurysm: a case report. CVIR Endovasc 2020; 3:91. [PMID: 33275193 PMCID: PMC7718367 DOI: 10.1186/s42155-020-00183-6] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2020] [Accepted: 11/26/2020] [Indexed: 01/02/2023] Open
Abstract
Background This case report demonstrates the value of IMPEDE-FX plugs in an embolization procedure of a false lumen of an infrarenal post-dissection aneurysm. Case presentation A 69-year-old patient was treated with mitral valve replacement, complicated by a Stanford type-A dissection. After 9 years he presented with an enlarging infrarenal post-dissection aneurysm. The false lumen was embolized using multiple IMPEDE-FX plugs as part of the treatment in addition to embolization of the inferior mesenteric artery and overstenting of the re-entry in the right iliac artery. At 15 months the CTA showed a fully thrombosed false lumen and remodeling of the true lumen. Conclusions The false lumen of an infrarenal post-dissection aneurysm can successfully be embolized using IMPEDE-FX embolization plugs as part of the treatment strategy. Prospective trials on patients with non-thrombosed false lumina are indicated.
Collapse
Affiliation(s)
- Anne-Jet S Jansen
- Department of Surgery, Rijnstate, P.O. Box 9555, 6800, TA, Arnhem, The Netherlands
| | - Paul M van Schaik
- Department of Surgery, Rijnstate, P.O. Box 9555, 6800, TA, Arnhem, The Netherlands
| | | | - Michel M P J Reijnen
- Department of Surgery, Rijnstate, P.O. Box 9555, 6800, TA, Arnhem, The Netherlands. .,Multi-Modality Medical Imaging Group, TechMed Centre, University of Twente, Enschede, The Netherlands.
| |
Collapse
|
19
|
Fletcher GK, Nash LD, Graul LM, Jang LK, Herting SM, Wilcox MD, Touchet TJ, Sweatt AK, McDougall MP, Wright SM, Maitland DJ. Chemical Modifications of Porous Shape Memory Polymers for Enhanced X-ray and MRI Visibility. Molecules 2020; 25:E4660. [PMID: 33066091 PMCID: PMC7587375 DOI: 10.3390/molecules25204660] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2020] [Revised: 10/07/2020] [Accepted: 10/12/2020] [Indexed: 12/02/2022] Open
Abstract
The goal of this work was to develop a shape memory polymer (SMP) foam with visibility under both X-ray and magnetic resonance imaging (MRI) modalities. A porous polymeric material with these properties is desirable in medical device development for applications requiring thermoresponsive tissue scaffolds with clinical imaging capabilities. Dual modality visibility was achieved by chemically incorporating monomers with X-ray visible iodine-motifs and MRI visible monomers with gadolinium content. Physical and thermomechanical characterization showed the effect of increased gadopentetic acid (GPA) on shape memory behavior. Multiple compositions showed brightening effects in pilot, T1-weighted MR imaging. There was a correlation between the polymeric density and X-ray visibility on expanded and compressed SMP foams. Additionally, extractions and indirect cytocompatibility studies were performed to address toxicity concerns of gadolinium-based contrast agents (GBCAs). This material platform has the potential to be used in a variety of medical devices.
Collapse
Affiliation(s)
- Grace K. Fletcher
- Texas A&M University Biomedical Engineering, Bizzell St, College Station, TX 77843, USA; (G.K.F.); (L.M.G.); (L.K.J.); (S.M.H.); (M.D.W.); (T.J.T.); (A.K.S.); (M.P.M.); (S.M.W.)
| | | | - Lance M. Graul
- Texas A&M University Biomedical Engineering, Bizzell St, College Station, TX 77843, USA; (G.K.F.); (L.M.G.); (L.K.J.); (S.M.H.); (M.D.W.); (T.J.T.); (A.K.S.); (M.P.M.); (S.M.W.)
| | - Lindy K. Jang
- Texas A&M University Biomedical Engineering, Bizzell St, College Station, TX 77843, USA; (G.K.F.); (L.M.G.); (L.K.J.); (S.M.H.); (M.D.W.); (T.J.T.); (A.K.S.); (M.P.M.); (S.M.W.)
| | - Scott M. Herting
- Texas A&M University Biomedical Engineering, Bizzell St, College Station, TX 77843, USA; (G.K.F.); (L.M.G.); (L.K.J.); (S.M.H.); (M.D.W.); (T.J.T.); (A.K.S.); (M.P.M.); (S.M.W.)
| | - Matthew D. Wilcox
- Texas A&M University Biomedical Engineering, Bizzell St, College Station, TX 77843, USA; (G.K.F.); (L.M.G.); (L.K.J.); (S.M.H.); (M.D.W.); (T.J.T.); (A.K.S.); (M.P.M.); (S.M.W.)
| | - Tyler J. Touchet
- Texas A&M University Biomedical Engineering, Bizzell St, College Station, TX 77843, USA; (G.K.F.); (L.M.G.); (L.K.J.); (S.M.H.); (M.D.W.); (T.J.T.); (A.K.S.); (M.P.M.); (S.M.W.)
| | - Ana Katarina Sweatt
- Texas A&M University Biomedical Engineering, Bizzell St, College Station, TX 77843, USA; (G.K.F.); (L.M.G.); (L.K.J.); (S.M.H.); (M.D.W.); (T.J.T.); (A.K.S.); (M.P.M.); (S.M.W.)
| | - Mary P. McDougall
- Texas A&M University Biomedical Engineering, Bizzell St, College Station, TX 77843, USA; (G.K.F.); (L.M.G.); (L.K.J.); (S.M.H.); (M.D.W.); (T.J.T.); (A.K.S.); (M.P.M.); (S.M.W.)
- Texas A&M University Electrical and Computer Engineering, Bizzell St, College Station, TX 77843, USA
| | - Steven M. Wright
- Texas A&M University Biomedical Engineering, Bizzell St, College Station, TX 77843, USA; (G.K.F.); (L.M.G.); (L.K.J.); (S.M.H.); (M.D.W.); (T.J.T.); (A.K.S.); (M.P.M.); (S.M.W.)
- Texas A&M University Electrical and Computer Engineering, Bizzell St, College Station, TX 77843, USA
| | - Duncan J. Maitland
- Texas A&M University Biomedical Engineering, Bizzell St, College Station, TX 77843, USA; (G.K.F.); (L.M.G.); (L.K.J.); (S.M.H.); (M.D.W.); (T.J.T.); (A.K.S.); (M.P.M.); (S.M.W.)
- Shape Memory Medical Inc., Santa Clara, CA 95054, USA;
| |
Collapse
|
20
|
Shape Memory Polymer Foams Synthesized Using Glycerol and Hexanetriol for Enhanced Degradation Resistance. Polymers (Basel) 2020; 12:polym12102290. [PMID: 33036235 PMCID: PMC7600845 DOI: 10.3390/polym12102290] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2020] [Revised: 10/01/2020] [Accepted: 10/05/2020] [Indexed: 01/21/2023] Open
Abstract
Shape memory polymer foams have been used in a wide range of medical applications, including, but not limited to, vessel occlusion and aneurysm treatment. This unique polymer system has been proven to shape-fill a void, which makes it useful for occlusion applications. While the shape memory polymer foam has superior performance and healing outcomes compared to its leading competitors, some device applications may benefit from longer material degradation times, or degradation-resistant formulations with increased fibrous encapsulation. In this study, biostable shape memory polymer foams were synthesized, and their physical and chemical properties were characterized as an initial evaluation of feasibility for vascular occlusion applications. After characterizing their shape memory behavior in an aqueous environment, degradation of this polymer system was studied in vitro using accelerated oxidative and hydrolytic solutions. Results indicated that the foams did not lose mass under oxidative or hydrolytic conditions, and they maintained high shape recovery in aqueous in vitro models. These degradation-resistant systems have potential for use in vascular occlusion and other wound healing applications that benefit from permanent, space-filling shape memory behavior.
Collapse
|
21
|
Fisher H, Woolard P, Ross C, Kunkel R, Bohnstedt BN, Liu Y, Lee CH. Thermomechanical data of polyurethane shape memory polymer: Considering varying compositions. Data Brief 2020; 32:106294. [PMID: 32984481 PMCID: PMC7495509 DOI: 10.1016/j.dib.2020.106294] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2020] [Revised: 08/31/2020] [Accepted: 09/03/2020] [Indexed: 11/25/2022] Open
Abstract
This article presents data from the investigation of the thermal characteristics and mechanical behaviors of twelve different compositions of a polyurethane shape memory polymer (SMP). Each of the SMP compositions has a unique molar ratio of three monomers: (i) hexamethylene diisocyanate (HDI), (ii) N,N,N',N'-Tetrakis(2-Hydroxypropyl)ethylenediamine (HPED), and (iii) Triethanolamine (TEA). The thermal characteristic datasets for each composition include the glass transition temperatures, as obtained from differential scanning calorimetry (DSC) and dynamic mechanical analysis (DMA), and the thermal degradation thresholds, as found from thermogravimetric analysis (TGA). The mechanical behaviors of the SMPs are represented by the failure stresses and strains, as obtained by cyclic tensile testing and failure testing, respectively. The interpretation of these measurements as well as a discussion of the potential usage of candidate SMP compositions for medical devices can be found in the companion article by Kunkel et al. (2018) [1], "Synthesis and characterization of bio-compatible shape memory polymers with potential applications to endovascular embolization of intracranial aneurysms."
Collapse
Affiliation(s)
- Hailey Fisher
- Biomechanics and Biomaterials Design Laboratory (BBDL), School of Aerospace and Mechanical Engineering, The University of Oklahoma, Norman, OK 73019, USA
| | - Payton Woolard
- Biomechanics and Biomaterials Design Laboratory (BBDL), School of Aerospace and Mechanical Engineering, The University of Oklahoma, Norman, OK 73019, USA
| | - Colton Ross
- Biomechanics and Biomaterials Design Laboratory (BBDL), School of Aerospace and Mechanical Engineering, The University of Oklahoma, Norman, OK 73019, USA
| | - Robert Kunkel
- Biomechanics and Biomaterials Design Laboratory (BBDL), School of Aerospace and Mechanical Engineering, The University of Oklahoma, Norman, OK 73019, USA
| | - Bradley N. Bohnstedt
- Department of Neurological Surgery, Indiana University School of Medicine, Indianapolis, IN 46202, USA
| | - Yingtao Liu
- Smart Materials and Intelligent Systems (SMIS) Laboratory, The University of Oklahoma, Norman, OK 73019, USA
| | - Chung-Hao Lee
- Biomechanics and Biomaterials Design Laboratory (BBDL), School of Aerospace and Mechanical Engineering, The University of Oklahoma, Norman, OK 73019, USA
- Institute of Biomedical Engineering, Science and Technology (IBEST), The University of Oklahoma, Norman, OK 73019, USA
| |
Collapse
|
22
|
Christmas N, Vakil AU, Hatch CJ, Dong S, Fikhman D, Beaman HT, Monroe MBB. Characterization of shape memory polymer foam hemostats in in vitro hemorrhagic wound models. J Biomed Mater Res B Appl Biomater 2020; 109:681-692. [PMID: 32969163 DOI: 10.1002/jbm.b.34732] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2020] [Revised: 08/19/2020] [Accepted: 09/15/2020] [Indexed: 11/05/2022]
Abstract
Shape memory polymer foam hemostats are a promising option for future hemorrhage control in battlefield wounds. To enable their use as hemostatic devices, they must be optimized in terms of formulation and architecture, and their safety and efficacy must be characterized in animal models. Relevant in vitro models can be used for device optimization to help mitigate the excess use of animals and reduce costs of clinical translation. In this work, a simplified gunshot wound model and a grade V liver injury model were constructed. The models were used to characterize the effects of shape memory polymer foam hemostat geometry on wall pressures, application/removal times, hemorrhage (fluid loss), and fluid absorption in comparison with clinical controls. It was found that there is no benefit in over-sizing the hemostatic device relative to wound volume and that geometry effects are dependent upon the wound type. These models provide a rapid means for elucidation of promising hemostat geometries and formulations for use in future in vivo testing.
Collapse
Affiliation(s)
- Nakira Christmas
- Department of Biomedical and Chemical Engineering, Syracuse Biomaterials Institute, and BioInspired Syracuse, Syracuse University, Syracuse, New York, USA
| | - Anand Utpal Vakil
- Department of Biomedical and Chemical Engineering, Syracuse Biomaterials Institute, and BioInspired Syracuse, Syracuse University, Syracuse, New York, USA
| | - Christopher J Hatch
- Department of Biomedical Engineering, California Polytechnic State University, San Luis Obispo, California, USA
| | - Shi Dong
- Department of Biomedical and Chemical Engineering, Syracuse Biomaterials Institute, and BioInspired Syracuse, Syracuse University, Syracuse, New York, USA
| | - David Fikhman
- Department of Biomedical and Chemical Engineering, Syracuse Biomaterials Institute, and BioInspired Syracuse, Syracuse University, Syracuse, New York, USA
| | - Henry T Beaman
- Department of Biomedical and Chemical Engineering, Syracuse Biomaterials Institute, and BioInspired Syracuse, Syracuse University, Syracuse, New York, USA
| | - Mary Beth B Monroe
- Department of Biomedical and Chemical Engineering, Syracuse Biomaterials Institute, and BioInspired Syracuse, Syracuse University, Syracuse, New York, USA
| |
Collapse
|
23
|
Kuang X, Roach DJ, Hamel CM, Yu K, Qi HJ. Materials, design, and fabrication of shape programmable polymers. ACTA ACUST UNITED AC 2020. [DOI: 10.1088/2399-7532/aba1d9] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
|
24
|
Jessen SL, Friedemann MC, Mullen AE, Ginn-Hedman AM, Herting SM, Maitland DJ, Clubb FJ. Micro-CT and histopathology methods to assess host response of aneurysms treated with shape memory polymer foam-coated coils versus bare metal coil occlusion devices. J Biomed Mater Res B Appl Biomater 2020; 108:2238-2249. [PMID: 31961062 PMCID: PMC7379400 DOI: 10.1002/jbm.b.34561] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2019] [Revised: 12/04/2019] [Accepted: 01/07/2020] [Indexed: 11/06/2022]
Abstract
Recent studies utilizing shape memory polymer foams to coat embolizing coils have shown potential benefits over current aneurysm treatments. In the current study utilizing a rabbit-elastase aneurysm model, the performance of test article (foam-coated coil [FCC]) and control (bare platinum coils [BPCs]) devices were compared at 30, 90, and 180 days using micro-CT and histological assessments. The host response was measured by identifying the cells regionally present within the aneurysm, and assessing the degree of residual debris and connective tissue. The 3D reconstructions of aneurysms provided context for histologic findings, and aided in the overall aneurysm assessment. At all time points, >75% of the cells categorized in each aneurysm were associated with a bioactive yet biocompatible host response (vs. the remainder of cells that were associated with acute inflammation). The extracellular matrix exhibited a transition from residual fibrin at 30 days to a greater degree of connective tissue at 90 and 180 days. Although the control BPC-treated aneurysms exhibited a greater degree of connective tissue at the earliest time point examined (30 days), by 180 days, the FCC-treated aneurysms had more connective tissue and less debris overall than the control aneurysms. When considering cell types and extracellular matrix composition, the overall host response scores were significantly better in FCC-treated aneurysms at the later time point. Based on the results of these metrics, the FCC device may lead to an advanced tissue remodeling response over BPC occlusion devices.
Collapse
Affiliation(s)
- Staci L. Jessen
- Department of Veterinary Pathobiology, Texas A&M University, College Station, Texas
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas
| | - Molly C. Friedemann
- Department of Veterinary Pathobiology, Texas A&M University, College Station, Texas
| | - Annmarie E. Mullen
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas
| | | | - Scott M. Herting
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas
| | - Duncan J. Maitland
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas
| | - Fred J. Clubb
- Department of Veterinary Pathobiology, Texas A&M University, College Station, Texas
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas
| |
Collapse
|
25
|
Jang LK, Fletcher GK, Monroe MBB, Maitland DJ. Biodegradable shape memory polymer foams with appropriate thermal properties for hemostatic applications. J Biomed Mater Res A 2020; 108:1281-1294. [PMID: 32061006 PMCID: PMC7364661 DOI: 10.1002/jbm.a.36901] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2019] [Revised: 02/08/2020] [Accepted: 02/10/2020] [Indexed: 11/11/2022]
Abstract
Shape memory polymer (SMP) foams are a promising material for hemostatic dressings due to their biocompatibility, high surface area, excellent shape recovery, and ability to quickly initiate blood clotting. Biodegradable SMP foams could eliminate the need for a secondary removal procedure of hemostatic material from the patients' wound, further facilitating wound healing. In this study, we developed hydrolytically and oxidatively biodegradable SMP foams by reacting polyols (triethanolamine or glycerol) with 6-aminocaproic acid or glycine to generate foaming monomers with degradable ester bonds. These monomers were used in foam synthesis to provide highly crosslinked SMP foam structures. The ester-containing foams showed clinically relevant thermal properties that were comparable to controls and excellent shape recovery within eight min. Triethanolamine-based ester-containing foams showed interconnected porous structure along with increased mechanical strength. Faster hydrolytic and oxidative biodegradation rates were achieved in ester-containing foams in comparison to controls. These biodegradable SMP foams with clinically applicable thermal properties possess great potential as an effective hemostatic device for use in hospitals or on battlefields.
Collapse
Affiliation(s)
- Lindy K. Jang
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas
| | - Grace K. Fletcher
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas
| | - Mary Beth B. Monroe
- Department of Biomedical and Chemical Engineering, Syracuse University, Syracuse, New York
| | - Duncan J. Maitland
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas
| |
Collapse
|
26
|
Jose S, George JJ, Siengchin S, Parameswaranpillai J. Introduction to Shape-Memory Polymers, Polymer Blends and Composites: State of the Art, Opportunities, New Challenges and Future Outlook. ADVANCED STRUCTURED MATERIALS 2020. [DOI: 10.1007/978-981-13-8574-2_1] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
|
27
|
Horn JD, Maitland DJ, Hartman J, Ortega JM. Computational study of clot formation in aneurysms treated with shape memory polymer foam. Med Eng Phys 2020; 75:65-71. [DOI: 10.1016/j.medengphy.2019.10.002] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2018] [Revised: 09/13/2019] [Accepted: 10/14/2019] [Indexed: 11/26/2022]
|
28
|
Jessen SL, Friedemann MC, Ginn-Hedman AM, Graul LM, Jokerst S, Robinson CB, Landsman TL, Clubb FJ, Maitland DJ. Microscopic Assessment of Healing and Effectiveness of a Foam-Based Peripheral Occlusion Device. ACS Biomater Sci Eng 2019; 6:2588-2599. [PMID: 32715083 DOI: 10.1021/acsbiomaterials.9b00895] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
The IMPEDE Embolization Plug is a catheter-delivered vascular occlusion device that utilizes a porous shape memory polymer foam as a scaffold for thrombus formation and distal coils to anchor the device within the vessel. In this study, we investigated the biological response of porcine arteries to the IMPEDE device by assessing the extent of healing and overall effectiveness in occluding the vessel at 30, 60, and 90 days. Compared to control devices (Amplatzer Vascular Plug and Nester Embolization Coils), the host response to IMPEDE showed increased cellular infiltration (accommodated by the foam scaffold), which led to advanced healing of the initial thrombus to mature collagenous connective tissue (confirmed by transmission electron microscopy (TEM)). Over time, the host response to the IMPEDE device included degradation of the foam by multinucleated giant cells, which promoted fibrin and polymer degradation and advanced the healing response. Device effectiveness, in terms of vessel occlusion, was evaluated histologically by assessing the degree of recanalization. Although instances of recanalization were often observed at all time points for both control and test articles, the mature connective tissue within the foam scaffold of the IMPEDE devices improved percent vessel occlusion; when recanalization was observed in IMPEDE-treated vessels, channels were exclusively peri-device rather than intradevice, as often observed in the controls, and the vessels mostly remained >75% occluded. Although total vessel occlusion provides the optimal ischemic effect, in cardiovascular pathology, there is a progressive ischemic effect on the downstream vasculature as a vessel narrows. As such, we expect a sustained ischemic therapeutic effect to be observed in vessels greater than 75% occluded. Overall, the current study suggests the IMPEDE device presents advantages over controls by promoting an enhanced degree of healing within the foam scaffold, which decreases the likelihood of intradevice recanalization and ultimately may lead to a sustained ischemic therapeutic effect.
Collapse
Affiliation(s)
- Staci L Jessen
- Department of Veterinary Pathobiology, Texas A&M University, College Station, Texas 77845-4467, United States.,Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77843-3120, United States
| | - Molly C Friedemann
- Department of Veterinary Pathobiology, Texas A&M University, College Station, Texas 77845-4467, United States
| | - Anne-Marie Ginn-Hedman
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77843-3120, United States
| | - Lance M Graul
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77843-3120, United States
| | - Steven Jokerst
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77843-3120, United States
| | - Cedric B Robinson
- Department of Veterinary Pathobiology, Texas A&M University, College Station, Texas 77845-4467, United States
| | - Todd L Landsman
- Shape Memory Medical Inc., Santa Clara, California 95054, United States
| | - Fred J Clubb
- Department of Veterinary Pathobiology, Texas A&M University, College Station, Texas 77845-4467, United States.,Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77843-3120, United States
| | - Duncan J Maitland
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77843-3120, United States.,Shape Memory Medical Inc., Santa Clara, California 95054, United States
| |
Collapse
|
29
|
Hu J, Albadawi H, Oklu R, Chong BW, Deipolyi AR, Sheth RA, Khademhosseini A. Advances in Biomaterials and Technologies for Vascular Embolization. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2019; 31:e1901071. [PMID: 31168915 PMCID: PMC7014563 DOI: 10.1002/adma.201901071] [Citation(s) in RCA: 127] [Impact Index Per Article: 21.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/15/2019] [Revised: 03/24/2019] [Indexed: 05/03/2023]
Abstract
Minimally invasive transcatheter embolization is a common nonsurgical procedure in interventional radiology used for the deliberate occlusion of blood vessels for the treatment of diseased or injured vasculature. A wide variety of embolic agents including metallic coils, calibrated microspheres, and liquids are available for clinical practice. Additionally, advances in biomaterials, such as shape-memory foams, biodegradable polymers, and in situ gelling solutions have led to the development of novel preclinical embolic agents. The aim here is to provide a comprehensive overview of current and emerging technologies in endovascular embolization with respect to devices, materials, mechanisms, and design guidelines. Limitations and challenges in embolic materials are also discussed to promote advancement in the field.
Collapse
Affiliation(s)
- Jingjie Hu
- Division of Vascular & Interventional Radiology, Minimally Invasive Therapeutics Laboratory, Mayo Clinic, 13400 East Shea Blvd., Scottsdale, Arizona 85259, USA
| | - Hassan Albadawi
- Division of Vascular & Interventional Radiology, Minimally Invasive Therapeutics Laboratory, Mayo Clinic, 13400 East Shea Blvd., Scottsdale, Arizona 85259, USA
| | - Rahmi Oklu
- Division of Vascular & Interventional Radiology, Minimally Invasive Therapeutics Laboratory, Mayo Clinic, 13400 East Shea Blvd., Scottsdale, Arizona 85259, USA
| | - Brian W Chong
- Departments of Radiology and Neurological Surgery, Mayo Clinic, 13400 East Shea Blvd., Scottsdale, Arizona 85259, USA
| | - Amy R. Deipolyi
- Department of Interventional Radiology, Memorial Sloan Kettering Cancer Center, Weill Cornell Medical Center, 1275 York Avenue, New York, New York 10065, USA
| | - Rahul A. Sheth
- Department of Interventional Radiology, The University of Texas MD Anderson Cancer Center, Houston, Texas 77054, USA
| | - Ali Khademhosseini
- Department of Bioengineering, Department of Radiological Sciences, Department of Chemical and Biomolecular Engineering, Center for Minimally Invasive Therapeutics, California Nanosystems Institute, University of California, 410 Westwood Plaza, Los Angeles, California 90095, USA
| |
Collapse
|
30
|
Watkins AC, Huasen AB, Hill A, Nand P, Holden A. Endovascular Aortic Repair for Early Complications After Implantation of the Thoraflex Hybrid Graft. Ann Thorac Surg 2019; 107:e171-e174. [DOI: 10.1016/j.athoracsur.2018.07.061] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/03/2018] [Revised: 07/06/2018] [Accepted: 07/09/2018] [Indexed: 01/16/2023]
|
31
|
Horn JD, Maitland DJ, Hartman J, Ortega JM. A computational thrombus formation model: application to an idealized two-dimensional aneurysm treated with bare metal coils. Biomech Model Mechanobiol 2018; 17:1821-1838. [DOI: 10.1007/s10237-018-1059-y] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2017] [Accepted: 07/21/2018] [Indexed: 10/28/2022]
|
32
|
|
33
|
Peterson GI, Dobrynin AV, Becker ML. Biodegradable Shape Memory Polymers in Medicine. Adv Healthc Mater 2017; 6. [PMID: 28941154 DOI: 10.1002/adhm.201700694] [Citation(s) in RCA: 88] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2017] [Revised: 07/04/2017] [Indexed: 01/13/2023]
Abstract
Shape memory materials have emerged as an important class of materials in medicine due to their ability to change shape in response to a specific stimulus, enabling the simplification of medical procedures, use of minimally invasive techniques, and access to new treatment modalities. Shape memory polymers, in particular, are well suited for such applications given their excellent shape memory performance, tunable materials properties, minimal toxicity, and potential for biodegradation and resorption. This review provides an overview of biodegradable shape memory polymers that have been used in medical applications. The majority of biodegradable shape memory polymers are based on thermally responsive polyesters or polymers that contain hydrolyzable ester linkages. These materials have been targeted for use in applications pertaining to embolization, drug delivery, stents, tissue engineering, and wound closure. The development of biodegradable shape memory polymers with unique properties or responsiveness to novel stimuli has the potential to facilitate the optimization and development of new medical applications.
Collapse
Affiliation(s)
- Gregory I. Peterson
- The University of Akron Department of Polymer Science Akron OH 44325‐3909 USA
| | - Andrey V. Dobrynin
- The University of Akron Department of Polymer Science Akron OH 44325‐3909 USA
| | - Matthew L. Becker
- The University of Akron Department of Polymer Science Akron OH 44325‐3909 USA
| |
Collapse
|
34
|
|
35
|
Nash LD, Browning Monroe MB, Ding YH, Ezell KP, Boyle AJ, Kadirvel R, Kallmes DF, Maitland DJ. Increased X-ray Visualization of Shape Memory Polymer Foams by Chemical Incorporation of Iodine Motifs. Polymers (Basel) 2017; 9. [PMID: 30034862 PMCID: PMC6052870 DOI: 10.3390/polym9080381] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/21/2023] Open
Abstract
Shape memory polymers can be programmed into a secondary geometry and recovered to their primary geometry with the application of a controlled stimulus. Porous shape memory polymer foam scaffolds that respond to body temperature show particular promise for embolic medical applications. A limitation for the minimally invasive delivery of these materials is an inherent lack of X-ray contrast. In this work, a triiodobenzene containing a monomer was incorporated into a shape memory polymer foam material system to chemically impart X-ray visibility and increase material toughness. Composition and process changes enabled further control over material density and thermomechanical properties. The proposed material system demonstrates a wide range of tailorable functional properties for the design of embolic medical devices, including X-ray visibility, expansion rate, and porosity. Enhanced visualization of these materials can improve the acute performance of medical devices used to treat vascular malformations, and the material porosity provides a healing scaffold for durable occlusion.
Collapse
Affiliation(s)
- Landon D. Nash
- Biomedical Engineering, Texas A&M University, College Station, TX 77843, USA; (L.D.N.); (M.B.B.M.); (K.P.E.); (A.J.B.)
| | - Mary Beth Browning Monroe
- Biomedical Engineering, Texas A&M University, College Station, TX 77843, USA; (L.D.N.); (M.B.B.M.); (K.P.E.); (A.J.B.)
| | - Yong-Hong Ding
- Department of Radiology, Mayo Clinic, Rochester, MN 55905, USA; (Y.-H.D.); (R.K.); (D.F.K.)
| | - Kendal P. Ezell
- Biomedical Engineering, Texas A&M University, College Station, TX 77843, USA; (L.D.N.); (M.B.B.M.); (K.P.E.); (A.J.B.)
| | - Anthony J. Boyle
- Biomedical Engineering, Texas A&M University, College Station, TX 77843, USA; (L.D.N.); (M.B.B.M.); (K.P.E.); (A.J.B.)
| | - Ramanathan Kadirvel
- Department of Radiology, Mayo Clinic, Rochester, MN 55905, USA; (Y.-H.D.); (R.K.); (D.F.K.)
| | - David F. Kallmes
- Department of Radiology, Mayo Clinic, Rochester, MN 55905, USA; (Y.-H.D.); (R.K.); (D.F.K.)
| | - Duncan J. Maitland
- Biomedical Engineering, Texas A&M University, College Station, TX 77843, USA; (L.D.N.); (M.B.B.M.); (K.P.E.); (A.J.B.)
- Correspondence: ; Tel.: +1-979-458-3471
| |
Collapse
|
36
|
Chen T, Han H, Jia F, Jin Q, Ji J. On-Demand Shape Recovery Kinetics Modulation with a Wide Regulation Range and Spatially Heterogeneous Shape Recovery Rate. THE JOURNAL OF PHYSICAL CHEMISTRY C 2017; 121:11144-11150. [DOI: 10.1021/acs.jpcc.7b02759] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/09/2024]
Affiliation(s)
- Tingting Chen
- MOE Key Laboratory of Macromolecule
Synthesis and Functionalization of Ministry of Education, Department
of Polymer Science and Engineering, Zhejiang University, Hangzhou, 310027, China
| | - Haijie Han
- MOE Key Laboratory of Macromolecule
Synthesis and Functionalization of Ministry of Education, Department
of Polymer Science and Engineering, Zhejiang University, Hangzhou, 310027, China
| | - Fan Jia
- MOE Key Laboratory of Macromolecule
Synthesis and Functionalization of Ministry of Education, Department
of Polymer Science and Engineering, Zhejiang University, Hangzhou, 310027, China
| | - Qiao Jin
- MOE Key Laboratory of Macromolecule
Synthesis and Functionalization of Ministry of Education, Department
of Polymer Science and Engineering, Zhejiang University, Hangzhou, 310027, China
| | - Jian Ji
- MOE Key Laboratory of Macromolecule
Synthesis and Functionalization of Ministry of Education, Department
of Polymer Science and Engineering, Zhejiang University, Hangzhou, 310027, China
| |
Collapse
|
37
|
Nathan AL, Fletcher GK, Monroe MBB, Hwang W, Herting SM, Hasan SM, Keller BK, Maitland DJ. Particulate Release From Nanoparticle-Loaded Shape Memory Polymer Foams. J Med Device 2017; 11:0110091-110099. [PMID: 28179975 DOI: 10.1115/1.4035547] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2016] [Revised: 12/07/2016] [Indexed: 11/08/2022] Open
Abstract
Highly porous, open-celled shape memory polymer (SMP) foams are being developed for a number of vascular occlusion devices. Applications include abdominal aortic and neurovascular aneurysm or peripheral vascular occlusion. A major concern with implanting these high surface area materials in the vasculature is the potential to generate unacceptable particulate burden, in terms of number, size, and composition. This study demonstrates that particulate numbers and sizes in SMP foams are in compliance with limits stated by the most relevant standard and guidance documents. Particulates were quantified in SMP foams as made, postreticulation, and after incorporating nanoparticles intended to increase material toughness and improve radiopacity. When concentrated particulate treatments were administered to fibroblasts, they exhibited high cell viability (100%). These results demonstrate that the SMP foams do not induce an unacceptable level of risk to potential vascular occlusion devices due to particulate generation.
Collapse
Affiliation(s)
- Adam L Nathan
- Biomedical Engineering, Texas A&M University, College Station, TX 77843
| | - Grace K Fletcher
- Biomedical Engineering, Texas A&M University, College Station, TX 77843
| | | | - Wonjun Hwang
- Shape Memory Medical, Inc., Santa Clara, CA 95054
| | - Scott M Herting
- Biomedical Engineering, Texas A&M University, College Station, TX 77843
| | - Sayyeda M Hasan
- Biomedical Engineering, Texas A&M University, College Station, TX 77843
| | - Brandis K Keller
- Biomedical Engineering, Texas A&M University, College Station, TX 77843
| | - Duncan J Maitland
- Biomedical Engineering, Texas A&M University, College Station, TX 77843; Shape Memory Medical, Inc., Santa Clara, CA 95054 e-mail:
| |
Collapse
|