1
|
Szebeni D, Told R, Kunsági-Máté S, Szalma J, Maróti P, Böddi K, Lempel E. Monomer elution and shrinkage stress analysis of addition-fragmentation chain-transfer-modified resin composites in relation to the curing protocol. Dent Mater 2024; 40:1611-1623. [PMID: 39079764 DOI: 10.1016/j.dental.2024.07.029] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2024] [Revised: 07/25/2024] [Accepted: 07/26/2024] [Indexed: 09/17/2024]
Abstract
OBJECTIVE The purpose was to compare the effects of rapid (3 s) and conventional (20 s) polymerization protocols (PP) of mono- and multichip LED curing units (LCU) on shrinkage stress (SS) and monomer elution (ME) in bulk-fill resin-based composites (RBC) with and without addition-fragmentation chain-transfer (AFCT) monomer. METHODS Cylindrical (5x4mm) specimens were prepared from two RBCs containing different AFCT monomers (Filtek OneBulk-FOB; Tetric PowerFill-TPF) and one without (Tetric EvoCeram Bulk-TEC). After soaking for 3, 10, and 14 days (75 % ethanol), ME was quantified using standard monomers by High-Performance Liquid Chromatography. SS was measured from the start of polymerization to 5 min using a Materials Testing Machine. The radiant exitance of LCUs was measured using a spectrophotometer. ANOVA and Tukey's post-hoc test, multivariate analysis and partial eta-squared statistics were used to analyze the data (p < 0.05). RESULTS AFCT-modification significantly decreased ME (p < 0.001). ME was reduced by half by day 10 and by one tenth by the end of the 14-day compared to the 3-day sampling. ME itself was dependent, whereas the percentage of monomers released was independent of the PP used (p > 0.05). FOB showed the lowest SS (p < 0.001), while there was no significant difference between TPF and TEC (p = 0.124). Both ME and SS were significantly influenced by material type and PP. SIGNIFICANCE The incorporation of the AFCT monomer reduced ME, but this was inversely related to a decrease in exposure time. SS values reduced by rapid PP in parallel with increasing ME values. The utilization of the AFCT molecule in conjunction with an appropriate resin-, initiator-system is of significant consequence for the kinetics of polymerization and the incorporation of monomers into the network.
Collapse
Affiliation(s)
- Donát Szebeni
- Department of Restorative Dentistry and Periodontology, University of Pécs Medical School, Tüzér Street 1, 7623, Pécs, Hungary
| | - Roland Told
- 3D Printing and Visualization Centre, University of Pécs, Boszorkány Street 2, 7624 Pécs, Hungary; Medical Skills Education and Innovation Centre, University of Pécs Medical School, Szigeti Street 12, 7624, Pécs, Hungary
| | - Sándor Kunsági-Máté
- Department of Organic and Medicinal Chemistry, University of Pécs, Faculty of Pharmacy, Honvéd Street 1, 7624, Pécs, Hungary; János Szentágothai Research Center, Ifjúság Street 12, 7624 Pécs, Hungary
| | - József Szalma
- Department of Oral and Maxillofacial Surgery, University of Pécs Medical School, Tüzér Street 1, 7623, Pécs, Hungary
| | - Péter Maróti
- 3D Printing and Visualization Centre, University of Pécs, Boszorkány Street 2, 7624 Pécs, Hungary; Medical Skills Education and Innovation Centre, University of Pécs Medical School, Szigeti Street 12, 7624, Pécs, Hungary
| | - Katalin Böddi
- Department of Biochemistry and Medical Chemistry, University of Pécs Medical School, Szigeti Street 12, 7624, Pécs, Hungary
| | - Edina Lempel
- Department of Restorative Dentistry and Periodontology, University of Pécs Medical School, Tüzér Street 1, 7623, Pécs, Hungary.
| |
Collapse
|
2
|
Miranda SB, Lins RBE, Santi MR, Denucci GC, Silva CCS, da Silva SDFF, Marques DDAV, Montes MAJR. Effect of Rapid High-Intensity Light-Curing on Increasing Transdentinal Temperature and Cell Viability: An In Vitro Study. Polymers (Basel) 2024; 16:1466. [PMID: 38891413 PMCID: PMC11175155 DOI: 10.3390/polym16111466] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2024] [Revised: 05/17/2024] [Accepted: 05/18/2024] [Indexed: 06/21/2024] Open
Abstract
BACKGROUND This study investigated effects of rapid high-intensity light-curing (3 s) on increasing transdentinal temperature and cell viability. METHODS A total of 40 dentin discs (0.5 mm) obtained from human molars were prepared, included in artificial pulp chambers (4.5 × 5 mm), and subjected to four light-curing protocols (n = 5), with a Valo Grand light curing unit: (i) 10 s protocol with a moderate intensity of 1000 mW/cm2 (Valo-10 s); (ii) 3 s protocol with a high intensity of 3200 mW/cm2 (Valo-3 s); (iii) adhesive system + Filtek Bulk-Fill Flow bulk-fill composite resin in 10 s (FBF-10 s); (iv) adhesive system + Tetric PowerFlow bulk-fill composite resin in 3 s (TPF-3 s). Transdentinal temperature changes were recorded with a type K thermocouple. Cell viability was assessed using the MTT assay. Data were analyzed using one-way ANOVA and Tukey tests for comparison between experimental groups (p < 0.05). RESULTS The 3 s high-intensity light-curing protocol generated a higher temperature than the 10 s moderate-intensity standard (p < 0.001). The Valo-10 s and Valo-3 s groups demonstrated greater cell viability than the FBF-10s and TPF-3 s groups and statistical differences were observed between the Valo-3 s and FBF-10 s groups (p = 0.023) and Valo-3 s and TPF-3 s (p = 0.025), with a potential cytotoxic effect for the FBF-10 s and TPF-3 s groups. CONCLUSIONS The 3 s rapid high-intensity light-curing protocol of bulk-fill composite resins caused a temperature increase greater than 10 s and showed cell viability similar to and comparable to the standard protocol.
Collapse
Affiliation(s)
| | | | - Marina Rodrigues Santi
- Piracicaba Dental School, University of Campinas, Piracicaba 13414-018, São Paulo, Brazil;
| | - Giovanna Corrêa Denucci
- Department of Cariology and Operative Dentistry, Indiana University School of Dentistry, Indianapolis, IN 46202, USA;
| | - Cleyton Cézar Souto Silva
- Department of Clinical Nurse, Federal University of Paraiba, João Pessoa 58058-600, Paraíba, Brazil;
| | | | | | | |
Collapse
|
3
|
Hamza B, Eliades T, Attin T, Schwendener S, Karygianni L. Initial bacterial adherence and biofilm formation on novel restorative materials used in paediatric dentistry. Dent Mater 2024; 40:573-579. [PMID: 38350744 DOI: 10.1016/j.dental.2024.02.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2023] [Revised: 01/25/2024] [Accepted: 02/06/2024] [Indexed: 02/15/2024]
Abstract
OBJECTIVE To evaluate the initial bacterial adherence and biofilm formation on novel restorative materials in paediatric dentistry and compare the results to stainless steel crown and primary enamel. MATERIALS AND METHODS Twenty-five samples (Diameter = 4 mm) from five restorative materials (Tetric Power Fill light cured for 3 s or 10 s, Fuji II LC, Equia Forte HT Fil, Cention Forte, Stainless-steel crown) and primary enamel were prepared. Four samples served for recording of surface roughness (Ra) using a contact profilometer, 21 samples were incubated in stimulated human saliva for 2 h (initial bacterial adherence) and 72 h (biofilm formation) and served to determine ion releasing and bacterial growth. After 2 and 72 h, the number of colony-forming units (CFU) per ml was counted and expressed in Log10 CFU/ml. Data were analysed with two-way ANOVA and Tuckey's multiple comparisons test (p < 0.05). RESULTS All tested materials showed similar initial bacterial adherence (p > 0.1). Stainless steel crown showed statistically significantly less biofilm formation than all other tested materials (p ≤ 0.02), except for Fuji II LC (p = 0.06). In terms of biofilm formation, the differences between all tested materials were not statistically significant (p ≥ 0.9). SIGNIFICANCE Novel restorative materials in paediatric dentistry show similar initial bacterial adherence and biofilm formation. However, compared to other restorative materials, stainless steel crowns demonstrate the lowest level of biofilm formation. Ion-releasing materials may not necessarily show better antimicrobial properties than conventional materials.
Collapse
Affiliation(s)
- Blend Hamza
- Clinic of Orthodontics and Pediatric Dentistry, Center of Dental Medicine, University of Zurich, Zurich, Switzerland.
| | - Theodore Eliades
- Clinic of Orthodontics and Pediatric Dentistry, Center of Dental Medicine, University of Zurich, Zurich, Switzerland
| | - Thomas Attin
- Clinic of Conservative and Preventive Dentistry, Center of Dental Medicine, University of Zurich, Zurich, Switzerland
| | - Sybille Schwendener
- Clinic of Conservative and Preventive Dentistry, Center of Dental Medicine, University of Zurich, Zurich, Switzerland
| | - Lamprini Karygianni
- Clinic of Conservative and Preventive Dentistry, Center of Dental Medicine, University of Zurich, Zurich, Switzerland
| |
Collapse
|
4
|
Duzyol M, Bayram P, Duzyol E, Aksak Karamese S. Assessing the impact of dental restorative materials on fibroblast cells: an immunohistochemical and ELISA analysis. Sci Rep 2024; 14:4725. [PMID: 38413631 PMCID: PMC10899243 DOI: 10.1038/s41598-024-54331-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2023] [Accepted: 02/12/2024] [Indexed: 02/29/2024] Open
Abstract
In this study, our aim was to investigate the effects of restorative materials such as composite, compomer and high viscosity glass ionomer, which are frequently used in dentistry, on L929 fibroblast cells by evaluating the oxidative stress parameters, pro- and anti-inflammatory cytokines, and apoptosis markers. L929 fibroblast cells were cultured, and dental filling materials were applied in two doses (50 and 100 µl). Immunohistochemical staining was performed for experimental groups with Anti-Bax and Anti-Caspase 9 antibodies. Then, ELISA technique was used to detect the level of TNF-alpha, TGF-beta, IL-1-beta, IL-6, IL-10, LPO and CAT. In the light of the data, the examined dental filling materials were effective on increasing the TGF-beta, IL-10, LPO and CAT levels, and decreasing the TNF-alpha, IL-1-beta, and IL-6 levels. The histological micrographs were also support the issues. When the levels of H-score in Caspase 9 labeled micrographs were evaluated, the mean of the control group was lower than the mean of the experimental groups. Biocompatibility varies according to the content of the material, the amount of residual monomer, and its solubility. Although all the experimental groups have cytotoxic effects, the least effect is seen in the Omnichroma group.
Collapse
Affiliation(s)
- Mustafa Duzyol
- Department of Restorative Dentistry, Faculty of Dentistry, Istanbul Medeniyet University, Istanbul, Turkey
| | - Pinar Bayram
- Department of Histology and Embryology, Faculty of Medicine, Kafkas University, Kars, Turkey
| | - Esra Duzyol
- Department of Pediatric Dentistry, Faculty of Dentistry, Istanbul Medeniyet University, 34200, Istanbul, Turkey.
| | - Selina Aksak Karamese
- Department of Histology and Embryology, Faculty of Medicine, Kafkas University, Kars, Turkey
| |
Collapse
|
5
|
Frank J, Tauböck TT, Zimmermann M, Attin T, Hamza B. Influence of high-irradiance light curing on the marginal integrity of composite restorations in primary teeth. BMC Oral Health 2023; 23:569. [PMID: 37574544 PMCID: PMC10424382 DOI: 10.1186/s12903-023-03291-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2023] [Accepted: 08/06/2023] [Indexed: 08/15/2023] Open
Abstract
BACKGROUND Reducing the necessary time to restore primary teeth improves the cooperation of paediatric patients. This study aimed to investigate the marginal integrity of restorations prepared with a bulk-fill resin-based composite (RBC) containing additional fragmentation chain transfer (AFCT) compared to a conventional RBC when light cured with a rapid high-irradiance (3 s) and a regular (10 s) curing mode. METHODS Forty class-II cavities were prepared in 40 primary molars. The molars were randomly divided into four groups based on the applied light-curing modes (regular: 10 s @ 1200 mW/cm2 or high-irradiance: 3 s @ 3000 mW/cm2) and the used restorative material (AFCT-containing bulk-fill RBC "Power Fill" or AFCT-free conventional RBC "Prime"). After thermo-mechanical loading, the marginal integrity was analysed using scanning electron microscopy. A beta regression model and pairwise comparisons were used to statistically analyse the data. RESULTS The mean marginal integrity (% ± SD) of the restorations for each group was as follows: Power Fill (10 s: 79.7 ± 15.6) (3 s: 77.6 ± 11.3), Prime (10 s: 69.7 ± 11.1) (3 s: 75.0 ± 9.7). The difference between the RBCs for the same light-curing mode was statistically significant (p ≤ 0.05). The difference between the light-curing modes for the same RBC was not statistically significant (p ˃ 0.5). CONCLUSIONS AFCT-containing bulk-fill RBC "Power Fill" achieves similar marginal integrity when light-cured with either high-irradiance or regular light-curing modes. "Power Fill" achieves better marginal integrity than the conventional RBC "Prime" regardless of the applied light-curing mode.
Collapse
Affiliation(s)
- Janina Frank
- Clinic of Conservative and Preventive Dentistry, Center of Dental Medicine, University of Zurich, Plattenstrasse 11, Zurich, 8032, Switzerland
| | - Tobias T Tauböck
- Clinic of Conservative and Preventive Dentistry, Center of Dental Medicine, University of Zurich, Plattenstrasse 11, Zurich, 8032, Switzerland
| | - Marcus Zimmermann
- Clinic of Conservative and Preventive Dentistry, Center of Dental Medicine, University of Zurich, Plattenstrasse 11, Zurich, 8032, Switzerland
| | - Thomas Attin
- Clinic of Conservative and Preventive Dentistry, Center of Dental Medicine, University of Zurich, Plattenstrasse 11, Zurich, 8032, Switzerland
| | - Blend Hamza
- Clinic of Orthodontics and Pediatric Dentistry, Center of Dental Medicine, University of Zurich, Plattenstrasse 11, Zürich, 8032, Switzerland.
| |
Collapse
|
6
|
Ilie N. Cytotoxic, Elastic-Plastic and Viscoelastic Behavior of Aged, Modern Resin-Based Dental Composites. Bioengineering (Basel) 2023; 10:bioengineering10020235. [PMID: 36829729 PMCID: PMC9952265 DOI: 10.3390/bioengineering10020235] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2023] [Revised: 02/02/2023] [Accepted: 02/06/2023] [Indexed: 02/12/2023] Open
Abstract
The development of resin-based composites (RBCs) is a delicate balance of antagonistic properties with direct clinical implications. The clear trend toward reducing filler size in modern RBCs solves esthetic deficiencies but reduces mechanical properties due to lower filler content and increases susceptibility to degradation due to larger filler-matrix interface. We evaluated a range of nano- and nano-hybrid RBCs, along with materials attempting to address shrinkage stress issues by implementing an Ormocer matrix or pre-polymerized fillers, and materials aiming to provide caries-protective benefit by incorporating bioactive fillers. The cytotoxic response of human gingival fibroblast (HGF) cells after exposure to the RBC eluates, which were collected for up to six months, was analyzed using a WST-1 assay. The microstructural features were characterized using a scanning electron microscopy and were related to the macroscopic and microscopic mechanical behaviors. The elastic-plastic and viscoelastic material behaviors were evaluated at the macroscopic and microscopic levels. The data were supplemented with fractography, Weibull analysis, and aging behavioral analysis. The results indicate that all RBCs are non-cytotoxic at adequate exposure. The amount of inorganic filler affects the elastic modulus, while only to a limited extent the flexural strength, and is well below the theoretical estimates. The nanoparticles and the agglomeration of nanoparticles in the RBCs help generate good mechanical properties and excellent reliability, but they are more prone to deterioration with aging. The pre-polymerized fillers lower the initial mechanical properties but are less sensitive to aging. Only the Ormocer retains its damping ability after aging. The strength and modulus of elasticity on the one hand and the damping capacity on the other are mutually exclusive and indicate the direction in which the RBCs should be further developed.
Collapse
Affiliation(s)
- Nicoleta Ilie
- Department of Conservative Dentistry and Periodontology, University Hospital, Ludwig-Maximilians-University, D-80336 Munich, Germany
| |
Collapse
|
7
|
Maucoski C, Price RB, Sullivan B, Guarneri JAG, Gusso B, Arrais CAG. In-vitro pulpal temperature increases when photo-curing bulk-fill resin-based composites using laser or light-emitting diode light curing units. J ESTHET RESTOR DENT 2023; 35:705-716. [PMID: 36738181 DOI: 10.1111/jerd.13022] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2022] [Revised: 01/03/2023] [Accepted: 01/14/2023] [Indexed: 02/05/2023]
Abstract
OBJECTIVE To evaluate the in vitro pulpal temperature rise (ΔT) within the pulp chamber when low- and high-viscosity bulk-fill resin composites are photo-cured using laser or contemporary light curing units (LCUs). MATERIALS AND METHODS The light output from five LCUs was measured. Non-retentive Class I and V cavities were prepared in one upper molar. Two T-type thermocouples were inserted into the pulp chamber. After the PT values reached 32°C under simulated pulp flow (0.026 mL/min), both cavities were restored with: Filtek One Bulk Fill (3 M), Filtek Bulk Fill Flow (3 M), Tetric PowerFill (Ivoclar Vivadent), or Tetric PowerFlow (Ivoclar Vivadent). The tooth was exposed as follows: Monet Laser (1 and 3 s), PowerCure (3 and 20 s), PinkWave (3 and 20 s), Valo X (5 and 20 s) and SmartLite Pro (20 s). The ΔT data were subjected to one-way ANOVA followed by Scheffe's post hoc test. RESULTS Monet 1 s (1.9 J) and PinkWave 20 s (30.1 J) delivered the least and the highest amount of energy, respectively. Valo X and PinkWave used for 20 s produced the highest ΔT values (3.4-4.1°C). Monet 1 s, PinkWave 3 s, PowerCure 3 s (except FB-Flow) and Monet 3 s for FB-One and TP-Fill produced the lowest ΔT values (0.9-1.7°C). No significant differences were found among composites. CONCLUSIONS Short 1- to 3-s exposures produced acceptable temperature rises, regardless of the composite. CLINICAL SIGNIFICANCE The energy delivered to the tooth by the LCUs affects the temperature rise inside the pulp. The short 1-3 s exposure times used in this study delivered the least amount of energy and produced a lower temperature rise. However, the RBC may not have received sufficient energy to be adequately photo-cured.
Collapse
Affiliation(s)
- Cristiane Maucoski
- Department of Restorative Dentistry, State University of Ponta Grossa, Ponta Grossa, Parana, Brazil.,Department of Dental Clinical Sciences, Faculty of Dentistry, Dalhousie University, Halifax, Nova Scotia, Canada
| | - Richard Bengt Price
- Department of Dental Clinical Sciences, Faculty of Dentistry, Dalhousie University, Halifax, Nova Scotia, Canada
| | - Braden Sullivan
- Department of Dental Clinical Sciences, Faculty of Dentistry, Dalhousie University, Halifax, Nova Scotia, Canada
| | | | - Bruno Gusso
- Department of Restorative Dentistry, State University of Ponta Grossa, Ponta Grossa, Parana, Brazil
| | | |
Collapse
|
8
|
Polymerization Kinetics and Development of Polymerization Shrinkage Stress in Rapid High-Intensity Light-Curing. Polymers (Basel) 2022; 14:polym14163296. [PMID: 36015552 PMCID: PMC9415313 DOI: 10.3390/polym14163296] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2022] [Revised: 08/08/2022] [Accepted: 08/11/2022] [Indexed: 11/17/2022] Open
Abstract
This study investigated polymerization kinetics, linear shrinkage, and shrinkage stress development for six contemporary composite materials of different viscosities cured using radiant exitances of 1100–2850 mW/cm2. Real-time measurements of degree of conversion, linear shrinkage, and shrinkage stress were performed over 5 min using Fourier-transform infrared spectrometry, a custom-made linometer, and a custom-made stress analyzer, respectively. For most tested variables, the factor “material” had a higher effect size than the factor “curing protocol”. Maximum polymerization rate and maximum shrinkage stress rate were the most affected by changes in curing conditions. In contrast, no significant effects of curing conditions were identified within each material for shrinkage stress values measured at the end of the 5 min observation period. Linear shrinkage and shrinkage stress values measured after 5 min were closely correlated (R = 0.905–0.982). The analysis of polymerization kinetics suggested that the two composites specifically designed for rapid light-curing responded to higher radiant exitances differently than other composites. Polymerization kinetics and shrinkage stress behavior of contemporary restorative composite materials of different viscosities were overall more affected by material type than differences in curing conditions. Subtle differences in polymerization kinetics behavior shown by the two composites specifically designed for rapid high-intensity light-curing did not translate into significant differences in the development of polymerization shrinkage stress.
Collapse
|
9
|
Ilie N. Universal Chromatic Resin-Based Composites: Aging Behavior Quantified by Quasi-Static and Viscoelastic Behavior Analysis. Bioengineering (Basel) 2022; 9:270. [PMID: 35877321 PMCID: PMC9312272 DOI: 10.3390/bioengineering9070270] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2022] [Revised: 06/20/2022] [Accepted: 06/21/2022] [Indexed: 11/17/2022] Open
Abstract
Universal chromatic dental resin-based composites were recently developed in an attempt to speed up the restoration process with the aim of making it easier for the practitioner to decide on a suitable shade and to avoid time-consuming matching and mixing of materials. The way in which color is created in the analyzed universal chromatic materials is innovative, as it is not only induced by selective light absorption via pigments (Venus Diamond ONE, Venus Pearl ONE), as is usual in regular composites (Charisma Classic, Charisma Topaz, Venus, Venus Diamond), but also by selective light reflection via particularized microstructures (Omnichroma). Material properties were assessed at 24 h post-polymerization and after artificial aging. Flexural strength (n = 20) and modulus were measured in a 3-point-bending test and complemented with fractography and Weibull analysis. Quasi-static (Martens, Vickers, and indentation hardness; elastic and total indentation work; creep, indentation depth) and viscoelastic (storage, loss, and indentation moduli; loss factor) behavior (n = 6) was measured by a depth-sensing indentation test equipped with a DMA module. The nanoscale silica/zirconia polymer core-shell structure in the structural-colored material induces similar or poorer mechanical properties compared with pigment-colored materials, which is related to the higher polymer content. For all materials, aging shows a clear influence on the measured properties, with the degree of degradation depending on the measurement scale.
Collapse
Affiliation(s)
- Nicoleta Ilie
- Department of Conservative Dentistry and Periodontology, University Hospital, LMU, Goethestr. 70, 80336 Munich, Germany
| |
Collapse
|