1
|
Flé G, Houten EV, Rémillard-Labrosse G, FitzHarris G, Cloutier G. Imaging the subcellular viscoelastic properties of mouse oocytes. Proc Natl Acad Sci U S A 2023; 120:e2213836120. [PMID: 37186851 PMCID: PMC10214128 DOI: 10.1073/pnas.2213836120] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2022] [Accepted: 04/16/2023] [Indexed: 05/17/2023] Open
Abstract
In recent years, cellular biomechanical properties have been investigated as an alternative to morphological assessments for oocyte selection in reproductive science. Despite the high relevance of cell viscoelasticity characterization, the reconstruction of spatially distributed viscoelastic parameter images in such materials remains a major challenge. Here, a framework for mapping viscoelasticity at the subcellular scale is proposed and applied to live mouse oocytes. The strategy relies on the principles of optical microelastography for imaging in combination with the overlapping subzone nonlinear inversion technique for complex-valued shear modulus reconstruction. The three-dimensional nature of the viscoelasticity equations was accommodated by applying an oocyte geometry-based 3D mechanical motion model to the measured wave field. Five domains-nucleolus, nucleus, cytoplasm, perivitelline space, and zona pellucida-could be visually differentiated in both oocyte storage and loss modulus maps, and statistically significant differences were observed between most of these domains in either property reconstruction. The method proposed herein presents excellent potential for biomechanical-based monitoring of oocyte health and complex transformations across lifespan. It also shows appreciable latitude for generalization to cells of arbitrary shape using conventional microscopy equipment.
Collapse
Affiliation(s)
- Guillaume Flé
- Laboratory of Biorheology and Medical Ultrasonics, University of Montreal Hospital Research Center, Montreal, QCH2X 0A9, Canada
| | - Elijah Van Houten
- Mechanical Engineering Department, University of Sherbrooke, Sherbrooke, QCJ1K 2R1, Canada
| | - Gaudeline Rémillard-Labrosse
- Oocyte and Embryo Research Laboratory, University of Montreal Hospital Research Center, Montreal, QCH2X 0A9, Canada
| | - Greg FitzHarris
- Oocyte and Embryo Research Laboratory, University of Montreal Hospital Research Center, Montreal, QCH2X 0A9, Canada
- Department of Obstetrics and Gynecology, University of Montreal, Montreal, QCH3T 1J4, Canada
| | - Guy Cloutier
- Laboratory of Biorheology and Medical Ultrasonics, University of Montreal Hospital Research Center, Montreal, QCH2X 0A9, Canada
- Department of Radiology, Radio-Oncology and Nuclear Medicine, and Institute of Biomedical Engineering, University of Montreal, Montreal, QCH3T 1J4, Canada
| |
Collapse
|
2
|
Kilian D, Kilian W, Troia A, Nguyen TD, Ittermann B, Zilberti L, Gelinsky M. 3D Extrusion Printing of Biphasic Anthropomorphic Brain Phantoms Mimicking MR Relaxation Times Based on Alginate-Agarose-Carrageenan Blends. ACS APPLIED MATERIALS & INTERFACES 2022; 14:48397-48415. [PMID: 36270624 PMCID: PMC9634698 DOI: 10.1021/acsami.2c12872] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/19/2022] [Accepted: 10/07/2022] [Indexed: 06/16/2023]
Abstract
The availability of adapted phantoms mimicking different body parts is fundamental to establishing the stability and reliability of magnetic resonance imaging (MRI) methods. The primary purpose of such phantoms is the mimicking of physiologically relevant, contrast-creating relaxation times T1 and T2. For the head, frequently examined by MRI, an anthropomorphic design of brain phantoms would imply the discrimination of gray matter and white matter (WM) within defined, spatially distributed compartments. Multichannel extrusion printing allows the layer-by-layer fabrication of multiple pastelike materials in a spatially defined manner with a predefined shape. In this study, the advantages of this method are used to fabricate biphasic brain phantoms mimicking MR relaxation times and anthropomorphic geometry. The printable ink was based on purely naturally derived polymers: alginate as a calcium-cross-linkable gelling agent, agarose, ι-carrageenan, and GdCl3 in different concentrations (0-280 μmol kg-1) as the paramagnetic component. The suggested inks (e.g., 3Alg-1Agar-6Car) fulfilled the requirements of viscoelastic behavior and printability of large constructs (>150 mL). The microstructure and distribution of GdCl3 were assessed by scanning electron microscopy (SEM) with energy-dispersive X-ray spectroscopy (EDX). In closely monitored steps of technological development and characterization, from monophasic and biphasic samples as printable inks and cross-linked gels, we describe the construction of large-scale phantom models whose relaxation times were characterized and checked for stability over time.
Collapse
Affiliation(s)
- David Kilian
- Centre
for Translational Bone, Joint and Soft Tissue Research, Faculty of
Medicine Carl Gustav Carus, Technische Universität
Dresden (TUD), Dresden01307, Germany
| | - Wolfgang Kilian
- Physikalisch-Technische
Bundesanstalt (PTB), Berlin10587, Germany
| | - Adriano Troia
- Istituto
Nazionale di Ricerca Metrologica (INRiM), Turin10135, Italy
| | - Thanh-Duc Nguyen
- Centre
for Translational Bone, Joint and Soft Tissue Research, Faculty of
Medicine Carl Gustav Carus, Technische Universität
Dresden (TUD), Dresden01307, Germany
| | - Bernd Ittermann
- Physikalisch-Technische
Bundesanstalt (PTB), Berlin10587, Germany
| | - Luca Zilberti
- Istituto
Nazionale di Ricerca Metrologica (INRiM), Turin10135, Italy
| | - Michael Gelinsky
- Centre
for Translational Bone, Joint and Soft Tissue Research, Faculty of
Medicine Carl Gustav Carus, Technische Universität
Dresden (TUD), Dresden01307, Germany
| |
Collapse
|
3
|
Triolo E, Khegai O, Ozkaya E, Rossi N, Alipour A, Fleysher L, Balchandani P, Kurt M. Design, Construction, and Implementation of a Magnetic Resonance Elastography Actuator for Research Purposes. Curr Protoc 2022; 2:e379. [PMID: 35286023 PMCID: PMC9517172 DOI: 10.1002/cpz1.379] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Magnetic resonance elastography (MRE) is a technique for determining the mechanical response of soft materials using applied harmonic deformation of the material and a motion-sensitive magnetic resonance imaging sequence. This technique can elucidate significant information about the health and development of human tissue such as liver and brain, and has been used on phantom models (e.g., agar, silicone) to determine their suitability for use as a mechanical surrogate for human tissues in experimental models. The applied harmonic deformation used in MRE is generated by an actuator, transmitted in bursts of a specified duration, and synchronized with the magnetic resonance signal excitation. These actuators are most often a pneumatic design (common for human tissues or phantoms) or a piezoelectric design (common for small animal tissues or phantoms). Here, we describe how to design and assemble both a pneumatic and a piezoelectric MRE actuator for research purposes. For each of these actuator types, we discuss displacement requirements, end-effector options and challenges, electronics and electronic-driving requirements and considerations, and full MRE implementation. We also discuss how to choose the actuator type, size, and power based on the intended material and use. © 2022 Wiley Periodicals LLC. Basic Protocol 1: Design, construction, and implementation of a convertible pneumatic MRE actuator for use with tissues and phantom models Basic Protocol 2: Design, construction, and implementation of a piezoelectric MRE actuator for localized excitation in phantom models.
Collapse
Affiliation(s)
- E.R. Triolo
- University of Washington, Dept. of Mechanical Engineering (3900 E Stevens Way NE Seattle, WA 98195)
| | - O. Khegai
- Icahn School of Medicine at Mount Sinai, BioMedical Engineering and Imaging Institute (1470 Madison Ave, New York City, NY 10029)
| | - E. Ozkaya
- Icahn School of Medicine at Mount Sinai, BioMedical Engineering and Imaging Institute (1470 Madison Ave, New York City, NY 10029)
| | - N. Rossi
- Stevens Institute of Technology, Dept. of Mechanical Engineering (1 Castle Point Terrace, Hoboken, NJ 07030)
| | - A. Alipour
- Icahn School of Medicine at Mount Sinai, BioMedical Engineering and Imaging Institute (1470 Madison Ave, New York City, NY 10029)
| | - L. Fleysher
- Icahn School of Medicine at Mount Sinai, BioMedical Engineering and Imaging Institute (1470 Madison Ave, New York City, NY 10029)
| | - P. Balchandani
- Icahn School of Medicine at Mount Sinai, BioMedical Engineering and Imaging Institute (1470 Madison Ave, New York City, NY 10029)
| | - M. Kurt
- University of Washington, Dept. of Mechanical Engineering (3900 E Stevens Way NE Seattle, WA 98195)
- Icahn School of Medicine at Mount Sinai, BioMedical Engineering and Imaging Institute (1470 Madison Ave, New York City, NY 10029)
| |
Collapse
|
4
|
Ozkaya E, Triolo ER, Rezayaraghi F, Abderezaei J, Meinhold W, Hong K, Alipour A, Kennedy P, Fleysher L, Ueda J, Balchandani P, Eriten M, Johnson CL, Yang Y, Kurt M. Brain-mimicking phantom for biomechanical validation of motion sensitive MR imaging techniques. J Mech Behav Biomed Mater 2021; 122:104680. [PMID: 34271404 DOI: 10.1016/j.jmbbm.2021.104680] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2021] [Revised: 05/07/2021] [Accepted: 06/30/2021] [Indexed: 10/20/2022]
Abstract
Motion sensitive MR imaging techniques allow for the non-invasive evaluation of biological tissues by using different excitation schemes, including physiological/intrinsic motions caused by cardiac pulsation or respiration, and vibrations caused by an external actuator. The mechanical biomarkers extracted through these imaging techniques have been shown to hold diagnostic value for various neurological disorders and conditions. Amplified MRI (aMRI), a cardiac gated imaging technique, can help track and quantify low frequency intrinsic motion of the brain. As for high frequency actuation, the mechanical response of brain tissue can be measured by applying external high frequency actuation in combination with a motion sensitive MR imaging sequence called Magnetic Resonance Elastography (MRE). Due to the frequency-dependent behavior of brain mechanics, there is a need to develop brain phantom models that can mimic the broadband mechanical response of the brain in order to validate motion-sensitive MR imaging techniques. Here, we have designed a novel phantom test setup that enables both the low and high frequency responses of a brain-mimicking phantom to be captured, allowing for both aMRI and MRE imaging techniques to be applied on the same phantom model. This setup combines two different vibration sources: a pneumatic actuator, for low frequency/intrinsic motion (1 Hz) for use in aMRI, and a piezoelectric actuator for high frequency actuation (30-60 Hz) for use in MRE. Our results show that in MRE experiments performed from 30 Hz through 60 Hz, propagating shear waves attenuate faster at higher driving frequencies, consistent with results in the literature. Furthermore, actuator coupling has a substantial effect on wave amplitude, with weaker coupling causing lower amplitude wave field images, specifically shown in the top-surface shear loading configuration. For intrinsic actuation, our results indicate that aMRI linearly amplifies motion up to at least an amplification factor of 9 for instances of both visible and sub-voxel motion, validated by varying power levels of pneumatic actuation (40%-80% power) under MR, and through video analysis outside the MRI scanner room. While this investigation used a homogeneous brain-mimicking phantom, our setup can be used to study the mechanics of non-homogeneous phantom configurations with bio-interfaces in the future.
Collapse
Affiliation(s)
- E Ozkaya
- Department of Mechanical Engineering, Stevens Institute of Technology, Hoboken, NJ, 07030, USA.
| | - E R Triolo
- Department of Mechanical Engineering, Stevens Institute of Technology, Hoboken, NJ, 07030, USA
| | - F Rezayaraghi
- Department of Mechanical Engineering, Stevens Institute of Technology, Hoboken, NJ, 07030, USA
| | - J Abderezaei
- Department of Mechanical Engineering, Stevens Institute of Technology, Hoboken, NJ, 07030, USA
| | - W Meinhold
- The George W. Woodruff of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA, 30332, USA
| | - K Hong
- BioMedical Engineering and Imaging Institute, Icahn School of Medicine at Mount Sinai, New York, NY, 10029, USA
| | - A Alipour
- BioMedical Engineering and Imaging Institute, Icahn School of Medicine at Mount Sinai, New York, NY, 10029, USA
| | - P Kennedy
- BioMedical Engineering and Imaging Institute, Icahn School of Medicine at Mount Sinai, New York, NY, 10029, USA
| | - L Fleysher
- BioMedical Engineering and Imaging Institute, Icahn School of Medicine at Mount Sinai, New York, NY, 10029, USA
| | - J Ueda
- The George W. Woodruff of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA, 30332, USA
| | - P Balchandani
- BioMedical Engineering and Imaging Institute, Icahn School of Medicine at Mount Sinai, New York, NY, 10029, USA
| | - M Eriten
- Department of Mechanical Engineering, University of Wisconsin-Madison, Madison, WI, 53706, USA
| | - C L Johnson
- Department of Biomedical Engineering, University of Deleware, Newark, DE, 19716, USA
| | - Y Yang
- BioMedical Engineering and Imaging Institute, Icahn School of Medicine at Mount Sinai, New York, NY, 10029, USA
| | - M Kurt
- Department of Mechanical Engineering, Stevens Institute of Technology, Hoboken, NJ, 07030, USA; BioMedical Engineering and Imaging Institute, Icahn School of Medicine at Mount Sinai, New York, NY, 10029, USA
| |
Collapse
|
5
|
Terem I, Dang L, Champagne A, Abderezaei J, Pionteck A, Almadan Z, Lydon AM, Kurt M, Scadeng M, Holdsworth SJ. 3D amplified MRI (aMRI). Magn Reson Med 2021; 86:1674-1686. [PMID: 33949713 PMCID: PMC8252598 DOI: 10.1002/mrm.28797] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2020] [Revised: 02/18/2021] [Accepted: 03/17/2021] [Indexed: 12/17/2022]
Abstract
Purpose Amplified MRI (aMRI) has been introduced as a new method of detecting and visualizing pulsatile brain motion in 2D. Here, we improve aMRI by introducing a novel 3D aMRI approach. Methods 3D aMRI was developed and tested for its ability to amplify sub‐voxel motion in all three directions. In addition, 3D aMRI was qualitatively compared to 2D aMRI on multi‐slice and 3D (volumetric) balanced steady‐state free precession cine data and phase contrast (PC‐MRI) acquired on healthy volunteers at 3T. Optical flow maps and 4D animations were produced from volumetric 3D aMRI data. Results 3D aMRI exhibits better image quality and fewer motion artifacts compared to 2D aMRI. The tissue motion was seen to match that of PC‐MRI, with the predominant brain tissue displacement occurring in the cranial‐caudal direction. Optical flow maps capture the brain tissue motion and display the physical change in shape of the ventricles by the relative movement of the surrounding tissues. The 4D animations show the complete brain tissue and cerebrospinal fluid (CSF) motion, helping to highlight the “piston‐like” motion of the ventricles. Conclusions Here, we introduce a novel 3D aMRI approach that enables one to visualize amplified cardiac‐ and CSF‐induced brain motion in striking detail. 3D aMRI captures brain motion with better image quality than 2D aMRI and supports a larger amplification factor. The optical flow maps and 4D animations of 3D aMRI may open up exciting applications for neurological diseases that affect the biomechanics of the brain and brain fluids.
Collapse
Affiliation(s)
- Itamar Terem
- Department of Electrical Engineering, Stanford University, Stanford, California, USA.,Department of Structural Biology, Stanford University, Stanford, California, USA
| | - Leo Dang
- Department of Anatomy and Medical Imaging & Centre for Brain Research, Faculty of Medical and Health Sciences, University of Auckland, Auckland, New Zealand.,Mātai Medical Research Institute, Gisborne-Tairāwhiti, New Zealand
| | - Allen Champagne
- Centre for Neuroscience Studies, Queen's University, Kingston, Ontario, Canada
| | - Javid Abderezaei
- Department of Mechanical Engineering, Stevens Institute of Technology, Hoboken, New Jersey, USA
| | - Aymeric Pionteck
- Department of Mechanical Engineering, Stevens Institute of Technology, Hoboken, New Jersey, USA
| | - Zainab Almadan
- Department of Anatomy and Medical Imaging & Centre for Brain Research, Faculty of Medical and Health Sciences, University of Auckland, Auckland, New Zealand
| | - Anna-Maria Lydon
- Centre for Advanced MRI, University of Auckland, Auckland, New Zealand
| | - Mehmet Kurt
- Department of Mechanical Engineering, Stevens Institute of Technology, Hoboken, New Jersey, USA.,Biomedical Engineering and Imaging Institute, Icahn School of Medicine at Mount Sinai, New York, New York, USA
| | - Miriam Scadeng
- Department of Anatomy and Medical Imaging & Centre for Brain Research, Faculty of Medical and Health Sciences, University of Auckland, Auckland, New Zealand.,Mātai Medical Research Institute, Gisborne-Tairāwhiti, New Zealand.,Department of Radiology, University of California, San Diego, California, USA
| | - Samantha J Holdsworth
- Department of Anatomy and Medical Imaging & Centre for Brain Research, Faculty of Medical and Health Sciences, University of Auckland, Auckland, New Zealand.,Mātai Medical Research Institute, Gisborne-Tairāwhiti, New Zealand
| |
Collapse
|
6
|
Herthum H, Dempsey SCH, Samani A, Schrank F, Shahryari M, Warmuth C, Tzschätzsch H, Braun J, Sack I. Superviscous properties of the in vivo brain at large scales. Acta Biomater 2021; 121:393-404. [PMID: 33326885 DOI: 10.1016/j.actbio.2020.12.027] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2020] [Revised: 12/08/2020] [Accepted: 12/10/2020] [Indexed: 12/28/2022]
Abstract
There is growing awareness that brain mechanical properties are important for neural development and health. However, published values of brain stiffness differ by orders of magnitude between static measurements and in vivo magnetic resonance elastography (MRE), which covers a dynamic range over several frequency decades. We here show that there is no fundamental disparity between static mechanical tests and in vivo MRE when considering large-scale properties, which encompass the entire brain including fluid filled compartments. Using gradient echo real-time MRE, we investigated the viscoelastic dispersion of the human brain in, so far, unexplored dynamic ranges from intrinsic brain pulsations at 1 Hz to ultralow-frequency vibrations at 5, 6.25, 7.8 and 10 Hz to the normal frequency range of MRE of 40 Hz. Surprisingly, we observed variations in brain stiffness over more than two orders of magnitude, suggesting that the in vivo human brain is superviscous on large scales with very low shear modulus of 42±13 Pa and relatively high viscosity of 6.6±0.3 Pa∙s according to the two-parameter solid model. Our data shed light on the crucial role of fluid compartments including blood vessels and cerebrospinal fluid (CSF) for whole brain properties and provide, for the first time, an explanation for the variability of the mechanical brain responses to manual palpation, local indentation, and high-dynamic tissue stimulation as used in elastography.
Collapse
|
7
|
McIlvain G, Ganji E, Cooper C, Killian ML, Ogunnaike BA, Johnson CL. Reliable preparation of agarose phantoms for use in quantitative magnetic resonance elastography. J Mech Behav Biomed Mater 2019; 97:65-73. [PMID: 31100487 DOI: 10.1016/j.jmbbm.2019.05.001] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2019] [Revised: 04/28/2019] [Accepted: 05/02/2019] [Indexed: 12/28/2022]
Abstract
Agarose phantoms are one type of phantom commonly used in developing in vivo brain magnetic resonance elastography (MRE) sequences because they are inexpensive and easy to work with, store, and dispose of; however, protocols for creating agarose phantoms are non-standardized and often result in inconsistent phantoms with significant variability in mechanical properties. Many magnetic resonance imaging (MRI) and ultrasound studies use phantoms, but often these phantoms are not tailored for desired mechanical properties and as such are too stiff or not mechanically consistent enough to be used in MRE. In this work, we conducted a systematic study of agarose phantom creation parameters to identify those factors that are most conducive to producing mechanically consistent agarose phantoms for MRE research. We found that cooling rate and liquid temperature affected phantom homogeneity. Phantom stiffness is affected by agar concentration (quadratically), by final liquid temperature and salt content in phantoms, and by the interaction of these two metrics each with stir rate. We captured and quantified the implied relationships with a regression model that can be used to estimate stiffness of resulting phantoms. Additionally, we characterized repeatability, stability over time, impact on MR signal parameters, and differences in agar gel microstructure. This protocol and regression model should prove beneficial in future MRE development studies that use phantoms to determine stiffness measurement accuracy.
Collapse
Affiliation(s)
- Grace McIlvain
- Department of Biomedical Engineering, University of Delaware, Newark, DE, USA
| | - Elahe Ganji
- Department of Mechanical Engineering, University of Delaware, Newark, DE, USA
| | - Catherine Cooper
- Department of Linguistics and Cognitive Science, University of Delaware, Newark, DE, USA
| | - Megan L Killian
- Department of Biomedical Engineering, University of Delaware, Newark, DE, USA
| | - Babatunde A Ogunnaike
- Department of Chemical and Biomolecular Engineering, University of Delaware, Newark, DE, USA
| | - Curtis L Johnson
- Department of Biomedical Engineering, University of Delaware, Newark, DE, USA.
| |
Collapse
|
8
|
McGarry M, Van Houten E, Solamen L, Gordon-Wylie S, Weaver J, Paulsen K. Uniqueness of poroelastic and viscoelastic nonlinear inversion MR elastography at low frequencies. ACTA ACUST UNITED AC 2019; 64:075006. [DOI: 10.1088/1361-6560/ab0a7d] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
|
9
|
Solamen LM, Gordon-Wylie SW, McGarry MD, Weaver JB, Paulsen KD. Phantom evaluations of low frequency MR elastography. ACTA ACUST UNITED AC 2019; 64:065010. [DOI: 10.1088/1361-6560/ab0290] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
|