Laaksomaa M, Aula A, Sarudis S, Keyriläinen J, Ahlroth J, Murtola A, Pynnönen K, Lehtonen T, Björkqvist M, Järvinen L, Rossi M. Surface-guided radiotherapy systems in locoregional deep inspiration breath hold radiotherapy for breast cancer - a multicenter study on the setup accuracy. Rep Pract Oncol Radiother 2024; 29:176-186. [PMID: 39143974 PMCID: PMC11321775 DOI: 10.5603/rpor.99673] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2023] [Accepted: 02/29/2024] [Indexed: 08/16/2024] Open
Abstract
Background Daily image-guided radiotherapy (IGRT) and deep inspiration breath hold (DIBH) technique are recommended for locoregional RT of breast cancer. The optimal workflow for a combination of surface-guided RT (SGRT) with DIBH technique is of current clinical interest. Materials and methods The setup accuracy at three hospitals was evaluated using different SGRT workflows. A total of 150 patients (2269 image pairs) were analyzed in three groups: patient setup with the AlignRT® SGRT system in Tampere (Site 1, n = 50), the Catalyst™ SGRT system in Turku (Site 2, n = 50) and the Catalyst™ SGRT system in Jönköping (Site 3, n = 50). Each site used their routine workflow with SGRT-based setup and IGRT positioning. Residual errors of the bony chest wall, thoracic vertebra (Th 1) and humeral head were evaluated using IGRT images. Results Systematic residual errors in the cranio-caudal (CC) direction and in pitch were generally larger at Site 2 than those at Sites 1 and 3 (p = 0.01-0.7). With daily IGRT, only a small difference (p = 0.01-0.9) was observed in residual random errors of bony structures in other directions between sites. Conclusion The introduction of SGRT and the use of daily IGRT lead to small residual errors when combining the best workflow practices from different hospitals. Our multicenter evaluation led to improved workflow by tightening the SGRT tolerances on Site 2 and fixation modification. Because of mainly small random errors, systematic posture errors in the images need to be corrected after posture correction with new setup surfaces. We recommend tight SGRT tolerances, good fixation and correction of systematic errors.
Collapse
Affiliation(s)
- Marko Laaksomaa
- Department of Oncology, Tampere University Hospital, Tampere, Finland
| | - Antti Aula
- Department of Oncology, Tampere University Hospital, Tampere, Finland
- Department of Medical Physics, Tampere University Hospital, Tampere, Finland
| | - Sebastian Sarudis
- Department of Medical Physics, County Hospital Ryhov, Jönköping, Sweden
| | - Jani Keyriläinen
- Department of Medical Physics, Turku University Hospital, Turku, Finland
- Department of Oncology and Radiotherapy, Turku University Hospital, Turku, Finland
| | - Jenni Ahlroth
- Department of Oncology, Tampere University Hospital, Tampere, Finland
| | - Anna Murtola
- Department of Oncology, Tampere University Hospital, Tampere, Finland
| | - Kiira Pynnönen
- Department of Oncology, Tampere University Hospital, Tampere, Finland
| | - Turkka Lehtonen
- Department of Oncology, Tampere University Hospital, Tampere, Finland
| | - Mikko Björkqvist
- Department of Medical Physics, Turku University Hospital, Turku, Finland
- Department of Oncology and Radiotherapy, Turku University Hospital, Turku, Finland
| | - Lauri Järvinen
- Department of Medical Physics, Turku University Hospital, Turku, Finland
- Department of Oncology and Radiotherapy, Turku University Hospital, Turku, Finland
| | - Maija Rossi
- Department of Oncology, Tampere University Hospital, Tampere, Finland
- Department of Medical Physics, Tampere University Hospital, Tampere, Finland
| |
Collapse
|
2
|
Lu W, Hong LX, Yamada N, Berry SL, Song Y, Choi W, Cerviño LI, Tang X, Mechalakos JG, Romesser PB, Powell S, Li G. Comparison of setup accuracy of optical surface image versus orthogonal x-ray images for VMAT of the left breast using deep-inspiration breath-hold. J Appl Clin Med Phys 2023; 24:e14117. [PMID: 37535396 PMCID: PMC10691624 DOI: 10.1002/acm2.14117] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2023] [Revised: 05/25/2023] [Accepted: 07/18/2023] [Indexed: 08/04/2023] Open
Abstract
To compare the setup accuracy of optical surface image (OSI) versus orthogonal x-ray images (2DkV) using cone beam computed tomography (CBCT) as ground truth for radiotherapy of left breast cancer in deep-inspiration breath-hold (DIBH). Ten left breast DIBH patients treated with volumetric modulated arc therapy (VMAT) were studied retrospectively. OSI, 2DkV, and CBCT were acquired weekly at treatment setup. OSI, 2DkV, and CBCT were registered to planning CT or planning DRR based on a breast surface region of interest (ROI), bony anatomy (chestwall and sternum), and both bony anatomy and breast surface, respectively. These registrations provided couch shifts for each imaging system. The setup errors, or the difference in couch shifts between OSI and CBCT were compared to those between 2DkV and CBCT. A second OSI was acquired during last beam delivery to evaluate intrafraction motion. The median absolute setup errors were (0.21, 0.27, 0.23 cm, 0.6°, 1.3°, 1.0°) for OSI, and (0.26, 0.24, 0.18 cm, 0.9°, 1.0°, 0.6°) for 2DkV in vertical, longitudinal and lateral translations, and in rotation, roll and pitch, respectively. None of the setup errors was significantly different between OSI and 2DkV. For both systems, the systematic and random setup errors were ≤0.6 cm and ≤1.5° in all directions. Nevertheless, larger setup errors were observed in some sessions in both systems. There was no correlation between OSI and CBCT whereas there was modest correlation between 2DkV and CBCT. The intrafraction motion in DIBH detected by OSI was small with median absolute translations <0.2 cm, and rotations ≤0.4°. Though OSI showed comparable and small setup errors as 2DkV, it showed no correlation with CBCT. We concluded that to achieve accurate setup for both bony anatomy and breast surface, daily 2DkV can't be omitted following OSI for left breast patients treated with DIBH VMAT.
Collapse
Affiliation(s)
- Wei Lu
- Department of Medical PhysicsMemorial Sloan Kettering Cancer CenterNew YorkNew YorkUSA
| | - Linda X. Hong
- Department of Medical PhysicsMemorial Sloan Kettering Cancer CenterNew YorkNew YorkUSA
| | - Nelson Yamada
- Department of Medical PhysicsMemorial Sloan Kettering Cancer CenterNew YorkNew YorkUSA
| | - Sean L. Berry
- Department of Medical PhysicsMemorial Sloan Kettering Cancer CenterNew YorkNew YorkUSA
| | - Yulin Song
- Department of Medical PhysicsMemorial Sloan Kettering Cancer CenterNew YorkNew YorkUSA
| | - Wookjin Choi
- Department of Medical PhysicsMemorial Sloan Kettering Cancer CenterNew YorkNew YorkUSA
| | - Laura I. Cerviño
- Department of Medical PhysicsMemorial Sloan Kettering Cancer CenterNew YorkNew YorkUSA
| | - Xiaoli Tang
- Department of Medical PhysicsMemorial Sloan Kettering Cancer CenterNew YorkNew YorkUSA
| | - James G. Mechalakos
- Department of Medical PhysicsMemorial Sloan Kettering Cancer CenterNew YorkNew YorkUSA
| | - Paul B. Romesser
- Department of Radiation OncologyMemorial Sloan Kettering Cancer CenterNew YorkNew YorkUSA
| | - Simon Powell
- Department of Radiation OncologyMemorial Sloan Kettering Cancer CenterNew YorkNew YorkUSA
| | - Guang Li
- Department of Medical PhysicsMemorial Sloan Kettering Cancer CenterNew YorkNew YorkUSA
| |
Collapse
|
3
|
Lu W, Li G, Hong L, Yorke E, Tang X, Mechalakos JG, Zhang P, Cerviño LI, Powell S, Berry SL. Reproducibility of chestwall and heart position using surface-guided versus RPM-guided DIBH radiotherapy for left breast cancer. J Appl Clin Med Phys 2022; 24:e13755. [PMID: 35993318 PMCID: PMC9859984 DOI: 10.1002/acm2.13755] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2022] [Revised: 06/27/2022] [Accepted: 08/26/2021] [Indexed: 01/27/2023] Open
Abstract
This study compared the reproducibility of chestwall and heart position using surface-guided versus RPM (real-time position management)-guided deep inspiration breath hold (DIBH) radiotherapy for left sided breast cancer. Forty DIBH patients under either surface-guided radiotherapy (SGRT) or RPM guidance were studied. For patients treated with tangential fields, reproducibility was measured as the displacements in central lung distance (CLD) and heart shadow to field edge distance (HFD) between pretreatment MV (megavoltage) images and planning DRRs (digitally reconstructed radiographs). For patients treated with volumetric modulated arc therapy (VMAT), sternum to isocenter (ISO) distance (StID), spine to rib edge distance (SpRD), and heart shadow to central axis (CAX) distance (HCD) between pretreatment kV images and planning DRRs were measured. These displacements were compared between SGRT and RPM-guided DIBH. In tangential patients, the mean absolute displacements of SGRT versus RPM guidance were 0.19 versus 0.23 cm in CLD, and 0.33 versus 0.62 cm in HFD. With respect to planning DRR, heart appeared closer to the field edge by 0.04 cm with surface imaging versus 0.62 cm with RPM. In VMAT patients, the displacements of surface imaging versus RPM guidance were 0.21 versus 0.15 cm in StID, 0.24 versus 0.19 cm in SpRD, and 0.72 versus 0.41 cm in HCD. Heart appeared 0.41 cm further away from CAX with surface imaging, whereas 0.10 cm closer to field CAX with RPM. None of the differences between surface imaging and RPM guidance was statistically significant. In conclusion, the displacements of chestwall were small and were comparable with SGRT- or RPM-guided DIBH. The position deviations of heart were larger than those of chestwall with SGRT or RPM. Although none of the differences between SGRT and RPM guidance were statistically significant, there was a trend that the position deviations of heart were smaller and more favorable with SGRT than with RPM guidance in tangential patients.
Collapse
Affiliation(s)
- Wei Lu
- Department of Medical PhysicsMemorial Sloan Kettering Cancer CenterNew YorkNew YorkUSA
| | - Guang Li
- Department of Medical PhysicsMemorial Sloan Kettering Cancer CenterNew YorkNew YorkUSA
| | - Linda Hong
- Department of Medical PhysicsMemorial Sloan Kettering Cancer CenterNew YorkNew YorkUSA
| | - Ellen Yorke
- Department of Medical PhysicsMemorial Sloan Kettering Cancer CenterNew YorkNew YorkUSA
| | - Xiaoli Tang
- Department of Medical PhysicsMemorial Sloan Kettering Cancer CenterNew YorkNew YorkUSA
| | - James G. Mechalakos
- Department of Medical PhysicsMemorial Sloan Kettering Cancer CenterNew YorkNew YorkUSA
| | - Pengpeng Zhang
- Department of Medical PhysicsMemorial Sloan Kettering Cancer CenterNew YorkNew YorkUSA
| | - Laura I. Cerviño
- Department of Medical PhysicsMemorial Sloan Kettering Cancer CenterNew YorkNew YorkUSA
| | - Simon Powell
- Department of Radiation OncologyMemorial Sloan Kettering Cancer CenterNew YorkNew YorkUSA
| | - Sean L. Berry
- Department of Medical PhysicsMemorial Sloan Kettering Cancer CenterNew YorkNew YorkUSA
| |
Collapse
|
4
|
TROG 14.04: Multicentre Study of Feasibility and Impact on Anxiety of DIBH in Breast Cancer Patients. Clin Oncol (R Coll Radiol) 2022; 34:e410-e419. [PMID: 35717318 DOI: 10.1016/j.clon.2022.05.020] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2022] [Revised: 05/13/2022] [Accepted: 05/27/2022] [Indexed: 11/20/2022]
Abstract
AIMS The aim of TROG 14.04 was to assess the feasibility of deep inspiration breath hold (DIBH) and its impact on radiation dose to the heart in patients with left-sided breast cancer undergoing radiotherapy. Secondary end points pertained to patient anxiety and cost of delivering a DIBH programme. MATERIALS AND METHODS The study comprised two groups - left-sided breast cancer patients engaging DIBH and right-sided breast cancer patients using free breathing through radiotherapy. The primary end point was the feasibility of DIBH, defined as left-sided breast cancer patients' ability to breath hold for 15 s, decrease in heart dose in DIBH compared with the free breathing treatment plan and reproducibility of radiotherapy delivery using mid-lung distance (MLD) assessed on electronic portal imaging as the surrogate. The time required for treatment delivery, patient-reported outcomes and resource requirement were compared between the groups. RESULTS Between February and November 2018, 32 left-sided and 30 right-sided breast cancer patients from six radiotherapy centres were enrolled. Two left-sided breast cancer patients did not undergo DIBH (one treated in free breathing as per investigator choice, one withdrawn). The mean heart dose was reduced from 2.8 Gy (free breathing) to 1.5 Gy (DIBH). Set-up reproducibility in the first week of treatment assessed by MLD was 1.88 ± 1.04 mm (average ± 1 standard deviation) for DIBH and 1.59 ± 0.93 mm for free breathing patients. Using a reproducibility cut-off for MLD of 2 mm (1 standard deviation) as per study protocol, DIBH was feasible for 67% of DIBH patients. Radiotherapy delivery using DIBH took about 2 min longer than for free breathing. Anxiety was not significantly different in DIBH patients and decreased over the course of treatment in both groups. CONCLUSION Although DIBH was shown to require about 2 min longer per treatment slot, it has the potential to reduce heart dose in left-sided breast cancer patients by nearly a half, provided careful assessment of breath hold reproducibility is carried out.
Collapse
|
5
|
Salvestrini V, Iorio GC, Borghetti P, De Felice F, Greco C, Nardone V, Fiorentino A, Gregucci F, Desideri I. The impact of modern radiotherapy on long-term cardiac sequelae in breast cancer survivor: a focus on deep inspiration breath-hold (DIBH) technique. J Cancer Res Clin Oncol 2021; 148:409-417. [PMID: 34853887 DOI: 10.1007/s00432-021-03875-1] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2021] [Accepted: 11/25/2021] [Indexed: 12/12/2022]
Abstract
INTRODUCTION One of the most feared side effects of radiotherapy (RT) in the setting of breast cancer (BC) patients is cardiac toxicity. This side effect can jeopardize the quality of life (QoL) of long-term survivors. The impact of modern techniques of RT such as deep inspiration breath hold (DIBH) have dramatically changed this setting. We report and discuss the results of the literature overview of this paper. MATERIALS AND METHODS Literature references were obtained with a PubMed query, hand searching, and clinicaltrials.gov. RESULTS We reported and discussed the toxicity of RT and the improvements due to the modern techniques in the setting of BC patients. CONCLUSIONS BC patients often have a long life expectancy, thus the RT should aim at limiting toxicities and at the same time maintaining the same high cure rates. Further studies are needed to evaluate the risk-benefit ratio to identify patients at higher risk and to tailor the treatment choices.
Collapse
Affiliation(s)
- V Salvestrini
- Radiation Oncology, Azienda Ospedaliero-Universitaria Careggi, University of Florence, Largo Brambilla 3, 50134, Florence, Italy.
| | - G C Iorio
- Radiation Oncology, University of Turin, Turin, Italy
| | - P Borghetti
- Radiation Oncology, University and SpedaliCivili, Brescia, Italy
| | - F De Felice
- Radiation Oncology, Policlinico Umberto I "Sapienza" University of Rome, Rome, Italy
| | - C Greco
- Radiation Oncology, Campus Bio-Medico University of Rome, Rome, Italy
| | - V Nardone
- RadiationOncology, Ospedale del Mare, Viale della Metamorfosi, Naples, Italy
| | - A Fiorentino
- Radiation Oncology, General Regional Hospital "F. Miulli, Acquaviva delle Fonti, Bari, Italy
| | - F Gregucci
- Radiation Oncology, General Regional Hospital "F. Miulli, Acquaviva delle Fonti, Bari, Italy
| | - I Desideri
- Radiation Oncology, Azienda Ospedaliero-Universitaria Careggi, University of Florence, Largo Brambilla 3, 50134, Florence, Italy
| |
Collapse
|
6
|
Is it advantageous to use deep inspiration breath hold (DIBH) over free breathing for FAST-Forward dose fractionation scheme in treating carcinoma of left-sided breast? A dosimetric study. JOURNAL OF RADIOTHERAPY IN PRACTICE 2021. [DOI: 10.1017/s1460396921000406] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
Abstract
Aim:
To study the effect of deep inspiration breath hold (DIBH) on Fast-Forward trial for left-sided breast radiotherapy dosimetrically using tangential field-in-field (FiF), flattening filtered volumetric-modulated arc therapy (FF-VMAT) and flattening filter free volumetric-modulated arc therapy (FFF-VMAT) in comparison with free breathing (FB).
Methods:
Computed tomography images were acquired on 15 patients with carcinoma of left breast in FB and DIBH. Planning target volume (PTV) and organs at risk were contoured on both image sets. Dose of 26 Gy in five daily fractions was prescribed to PTV. FiF, FF-VMAT and FFF-VMAT plans were created in treatment planning system on both FB and DIBH. PTV V95%, V107%, D0·1 cc, CI and HI, heart V1·5 Gy, V7 Gy, lung left V8 Gy, monitor units (MU) and beam ON time were used for evaluation. Different technique analysis in same breathing condition and FB versus DIBH for same planning technique were performed.
Results:
Mean of all 15 patients was reported as mean ± 1 standard deviation. PTV V95% was 97·55 ± 0·10 (FiF), 95·75 ± 0·66 (FF-VMAT) and 96·15 ± 0·46 (FFF-VMAT) in FB while 97·34 ± 0·50 (FiF), 96·03 ± 0·71 (FF-VMAT) and 95·86 ± 0·63 (FFF-VMAT) in DIBH. Heart V7 Gy was 8·53 ± 4·26 (FiF), 8·86 ± 2·20 (FF-VMAT) and 9·27 ± 2·46 (FFF-VMAT) in FB while 6·30 ± 2·98 (FiF), 5·23 ± 2·20 (FF-VMAT) and 4·68 ± 2·01 (FFF-VMAT) in DIBH. p-value of heart V7 Gy between FB and DIBH was 0·278 (FiF), 0·009 (FF-VMAT) and 0·003 (FFF-VMAT). Beam ON time for FFF-VMAT was reduced by 65% (FF-VMAT) and 11% (FiF).
Conclusion:
Conformal dose to PTV was achieved better with VMAT plans. FFF-VMAT was delivered in less time compared to FF-VMAT and FiF for 26 Gy in five fractions. Heart dose can be significantly minimised with DIBH for VMAT plans.
Collapse
|
7
|
Factors Affecting Mean Heart Dose in Patients Receiving Breast Radiotherapy from 2011 to 2018 in a Single Institution. J Med Imaging Radiat Sci 2020; 51:379-393. [DOI: 10.1016/j.jmir.2020.03.003] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2019] [Revised: 03/17/2020] [Accepted: 03/27/2020] [Indexed: 12/25/2022]
|