Bauer L, Woiczinski M, Thorwächter C, Müller PE, Holzapfel BM, Niethammer TR, Simon JM. Influence of kinematic alignment on femorotibial kinematics in medial stabilized TKA design compared to mechanical alignment. Arch Orthop Trauma Surg 2023; 143:4339-4347. [PMID: 36282314 PMCID: PMC10293425 DOI: 10.1007/s00402-022-04661-5] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/11/2022] [Accepted: 10/10/2022] [Indexed: 02/09/2023]
Abstract
INTRODUCTION Worldwide more and more primary knee replacements are being performed. Kinematic alignment (KA) as one of many methods of surgical alignment has been shown to have a significant impact on kinematics and function. The aim of the present study was to compare KA and mechanical alignment (MA) with regard to femorotibial kinematics. MATERIALS AND METHODS Eight fresh frozen human specimens were tested on a knee rig during active knee flexion from 30 to 130°. Within the same specimen a medial stabilized (MS) implant design was used first with KA and then with MA. RESULTS The femorotibial kinematics showed more internal rotation of the tibia in KA compared to MA. At the same time, there was a larger medial rotation point in KA. Both alignment methods showed femoral rollback over the knee bend. CONCLUSION Relating to an increased internal rotation and a more precise medial pivot point, it can be concluded that KA combined with a MS implant design may partially support the reproduction of physiological knee joint mechanics.
Collapse
Affiliation(s)
- L Bauer
- Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), University Hospital, LMU Munich, Marchioninistr. 15, 81377, Munich, Germany
| | - M Woiczinski
- Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), University Hospital, LMU Munich, Marchioninistr. 15, 81377, Munich, Germany
| | - C Thorwächter
- Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), University Hospital, LMU Munich, Marchioninistr. 15, 81377, Munich, Germany
| | - P E Müller
- Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), University Hospital, LMU Munich, Marchioninistr. 15, 81377, Munich, Germany
| | - B M Holzapfel
- Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), University Hospital, LMU Munich, Marchioninistr. 15, 81377, Munich, Germany
| | - T R Niethammer
- Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), University Hospital, LMU Munich, Marchioninistr. 15, 81377, Munich, Germany
| | - J-M Simon
- Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), University Hospital, LMU Munich, Marchioninistr. 15, 81377, Munich, Germany.
| |
Collapse
|
2
|
Brunner J, Jörgens M, Weigert M, Kümpel H, Fuermetz J. Veränderungen in der Ausrichtung des Beins durch Flexion und Rotation. ARTHROSKOPIE 2023. [DOI: 10.1007/s00142-023-00597-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/11/2023]
|
3
|
Brunner J, Jörgens M, Weigert M, Kümpel H, Degen N, Fuermetz J. Significant changes in lower limb alignment due to flexion and rotation-a systematic 3D simulation of radiographic measurements. Knee Surg Sports Traumatol Arthrosc 2023; 31:1483-1490. [PMID: 36595052 PMCID: PMC10050026 DOI: 10.1007/s00167-022-07302-x] [Citation(s) in RCA: 9] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/18/2022] [Accepted: 12/18/2022] [Indexed: 01/04/2023]
Abstract
BACKGROUND Many radiographic lower limb alignment measurements are dependent on patients' position, which makes a standardised image acquisition of long-leg radiographs (LLRs) essential for valid measurements. The purpose of this study was to investigate the influence of rotation and flexion of the lower limb on common radiological alignment parameters using three-dimensional (3D) simulation. METHODS Joint angles and alignment parameters of 3D lower limb bone models (n = 60), generated from computed tomography (CT) scans, were assessed and projected into the coronal plane to mimic radiographic imaging. Bone models were subsequently rotated around the longitudinal mechanical axis up to 15° inward/outward and additionally flexed along the femoral intercondylar axis up to 30°. This resulted in 28 combinations of rotation and flexion for each leg. The results were statistically analysed on a descriptive level and using a linear mixed effects model. RESULTS A total of 1680 simulations were performed. Mechanical axis deviation (MAD) revealed a medial deviation with increasing internal rotation and a lateral deviation with increasing external rotation. This effect increased significantly (p < 0.05) with combined flexion up to 30° flexion (- 25.4 mm to 25.2 mm). With the knee extended, the mean deviation of hip-knee-ankle angle (HKA) was small over all rotational steps but increased toward more varus/valgus when combined with flexion (8.4° to - 8.5°). Rotation alone changed the medial proximal tibial angle (MPTA) and the mechanical lateral distal femoral angle (mLDFA) in opposite directions, and the effects increased significantly (p < 0.05) when flexion was present. CONCLUSIONS Axial rotation and flexion of the 3D lower limb has a huge impact on the projected two-dimensional alignment measurements in the coronal plane. The observed effects were small for isolated rotation or flexion, but became pronounced and clinically relevant when there was a combination of both. This must be considered when evaluating X-ray images. Extension deficits of the knee make LLR prone to error and this calls into question direct postoperative alignment controls. LEVEL OF EVIDENCE III (retrospective cohort study).
Collapse
Affiliation(s)
- Josef Brunner
- Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), University Hospital, LMU, Marchioninistr. 15, 81377, Munich, Germany
| | - Maximilian Jörgens
- Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), University Hospital, LMU, Marchioninistr. 15, 81377, Munich, Germany.
| | | | - Hannah Kümpel
- Statistical Consulting Unit StaBLab, LMU, Munich, Germany
| | - Nikolaus Degen
- Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), University Hospital, LMU, Marchioninistr. 15, 81377, Munich, Germany
| | - Julian Fuermetz
- Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), University Hospital, LMU, Marchioninistr. 15, 81377, Munich, Germany.,Department of Trauma Surgery, BG Unfallklinik Murnau, Murnau, Germany
| |
Collapse
|
4
|
Gibbons KD, Malbouby V, Alvarez O, Fitzpatrick CK. Robust automatic hexahedral cartilage meshing framework enables population-based computational studies of the knee. Front Bioeng Biotechnol 2022; 10:1059003. [PMID: 36568304 PMCID: PMC9780478 DOI: 10.3389/fbioe.2022.1059003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2022] [Accepted: 11/25/2022] [Indexed: 12/13/2022] Open
Abstract
Osteoarthritis of the knee is increasingly prevalent as our population ages, representing an increasing financial burden, and severely impacting quality of life. The invasiveness of in vivo procedures and the high cost of cadaveric studies has left computational tools uniquely suited to study knee biomechanics. Developments in deep learning have great potential for efficiently generating large-scale datasets to enable researchers to perform population-sized investigations, but the time and effort associated with producing robust hexahedral meshes has been a limiting factor in expanding finite element studies to encompass a population. Here we developed a fully automated pipeline capable of taking magnetic resonance knee images and producing a working finite element simulation. We trained an encoder-decoder convolutional neural network to perform semantic image segmentation on the Imorphics dataset provided through the Osteoarthritis Initiative. The Imorphics dataset contained 176 image sequences with varying levels of cartilage degradation. Starting from an open-source swept-extrusion meshing algorithm, we further developed this algorithm until it could produce high quality meshes for every sequence and we applied a template-mapping procedure to automatically place soft-tissue attachment points. The meshing algorithm produced simulation-ready meshes for all 176 sequences, regardless of the use of provided (manually reconstructed) or predicted (automatically generated) segmentation labels. The average time to mesh all bones and cartilage tissues was less than 2 min per knee on an AMD Ryzen 5600X processor, using a parallel pool of three workers for bone meshing, followed by a pool of four workers meshing the four cartilage tissues. Of the 176 sequences with provided segmentation labels, 86% of the resulting meshes completed a simulated flexion-extension activity. We used a reserved testing dataset of 28 sequences unseen during network training to produce simulations derived from predicted labels. We compared tibiofemoral contact mechanics between manual and automated reconstructions for the 24 pairs of successful finite element simulations from this set, resulting in mean root-mean-squared differences under 20% of their respective min-max norms. In combination with further advancements in deep learning, this framework represents a feasible pipeline to produce population sized finite element studies of the natural knee from subject-specific models.
Collapse
|
5
|
Dupraz I, Thorwächter C, Grupp TM, Hammerschmid F, Woiczinski M, Jansson V, Müller PE, Steinbrück A. Impact of femoro-tibial size combinations and TKA design on kinematics. Arch Orthop Trauma Surg 2022; 142:1197-1212. [PMID: 34021794 DOI: 10.1007/s00402-021-03923-y] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/14/2020] [Accepted: 04/27/2021] [Indexed: 11/26/2022]
Abstract
INTRODUCTION The variability in patients' femoral and tibial anatomy requires to use different tibia component sizes with the same femoral component size. These size combinations are allowed by manufacturers, but the clinical impact remains unclear. Therefore, the goals of our study were to investigate whether combining different sizes has an impact on the kinematics for two well-established knee systems and to compare these systems' kinematics to the native kinematics. MATERIALS AND METHODS Six fresh frozen knee specimens were tested in a force controlled knee rig before and after implantation of a cruciate retaining (CR) and a posterior-stabilized (PS) implant. Femoro-tibial kinematics were recorded using a ultrasonic-based motion analysis system while performing a loaded squat from 30° to 130°. In each knee, the original best fit inlay was then replaced by different inlays simulating a smaller or bigger tibia component. The kinematics obtained with the simulated sizes were compared to the original inlay kinematics using descriptive statistics. RESULTS For all size combinations, the difference to the original kinematics reached an average of 1.3 ± 3.3 mm in translation and - 0.1 ± 1.2° in rotation with the CR implant. With the PS implant, the average differences reached 0.4 ± 2.7 mm and - 0.2 ± 0.8°. Among all knees, no size combination consistently resulted in significantly different kinematics. Each knee showed a singular kinematic pattern. For both knee systems, the rotation was smaller than in the native knee, but the direction of the rotation was preserved. The PS showed more rollback and the CR less rollback than the native knee. CONCLUSION TKA systems designed with a constant tibio-femoral congruency among size combinations should enable to combine different sizes without having substantial impact on the kinematics. The rotational pattern was preserved by both TKA systems, while the rollback could only be maintained by the PS design.
Collapse
Affiliation(s)
- Ingrid Dupraz
- Aesculap AG, Research and Development, Am Aesculap Platz 1, 78532, Tuttlingen, Germany.
| | - Christoph Thorwächter
- Department of Orthopaedic Surgery, Physical Medicine and Rehabilitation, University Hospital of Munich (LMU), Munich, Germany
| | - Thomas M Grupp
- Aesculap AG, Research and Development, Am Aesculap Platz 1, 78532, Tuttlingen, Germany
- Department of Orthopaedic Surgery, Physical Medicine and Rehabilitation, University Hospital of Munich (LMU), Munich, Germany
| | - Florian Hammerschmid
- Department of Orthopaedic Surgery, Physical Medicine and Rehabilitation, University Hospital of Munich (LMU), Munich, Germany
| | - Matthias Woiczinski
- Department of Orthopaedic Surgery, Physical Medicine and Rehabilitation, University Hospital of Munich (LMU), Munich, Germany
| | - Volkmar Jansson
- Department of Orthopaedic Surgery, Physical Medicine and Rehabilitation, University Hospital of Munich (LMU), Munich, Germany
| | - Peter E Müller
- Department of Orthopaedic Surgery, Physical Medicine and Rehabilitation, University Hospital of Munich (LMU), Munich, Germany
| | - Arnd Steinbrück
- Department of Orthopaedic Surgery, Physical Medicine and Rehabilitation, University Hospital of Munich (LMU), Munich, Germany
| |
Collapse
|
6
|
Hiyama S, Takahashi T, Takeshita K. Kinematically Aligned Total Knee Arthroplasty Did Not Show Superior Patient-Reported Outcome Measures: An Updated Meta-analysis of Randomized Controlled Trials with at Least 2-Year Follow-up. J Knee Surg 2022; 35:634-639. [PMID: 32927492 DOI: 10.1055/s-0040-1716494] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Kinematically aligned total knee arthroplasty (KATKA) was developed to improve the anatomical alignment of knee prostheses, assisting in restoring the native alignment of the knee and promoting physiological kinematics. Early clinical results were encouraging, showing better functional outcomes than with mechanically aligned total knee arthroplasty (MATKA). However, there have been concerns about implant survival, and follow-up at 10 years or more has not been reported. In addition, randomized controlled trials (RCTs) comparing KATKA with MATKA have reported inconsistent results. The current meta-analysis of RCTs with a minimum of 2 years of follow-up investigated the clinical and radiological differences between KATKA and MATKA. A systematic review of the English language literature resulted in the inclusion of four RCTs. The meta-analysis found no significant difference in any of the following parameters: postoperative range of motion for flexion (mean difference for KATKA - MATKA [MD], 1.7 degrees; 95% confidence interval [CI], -1.4 to 4.8 degrees; p = 0.29) and extension (MD, 0.10 degrees; 95% CI, -0.99 to 1.2 degrees; p = 0.86); Oxford Knee Score (MD, 0.10 points; 95% CI, -1.5 to 1.7 points; p = 0.90); Knee Society Score (MD, 1.6 points; 95% CI, -2.8 to 6.0 points; p = 0.49); and Knee Function Score (MD, 1.4 points; 95% CI, -4.9 to 7.8 points; p = 0.66). In addition, there was no significant difference between KATKA and MATKA in the rate of complications requiring reoperation or revision surgery (odds ratio, 1.01; 95% CI, 0.25-4.09; p = 0.99) or in the length of hospital stay (MD, 1.0 days; 95% CI, -0.2 to 2.2 days; p = 0.092). KATKA did not increase the number of patients with poor clinical results due to implant position, particularly for varus placement of the tibial component. In this meta-analysis based on four RCTs with a minimum of 2 years of follow-up, KATKA were only relevant to cruciate retaining TKA and could not be extrapolated to posterior stabilized TKA. Patient-reported outcome measures with KATKA were not superior to those with MATKA.
Collapse
Affiliation(s)
- Shuhei Hiyama
- Department of Orthopedic Surgery, School of Medicine, Jichi Medical University, Shimotsuke, Japan
| | - Tsuneari Takahashi
- Department of Orthopedic Surgery, School of Medicine, Jichi Medical University, Shimotsuke, Japan
| | - Katsushi Takeshita
- Department of Orthopedic Surgery, School of Medicine, Jichi Medical University, Shimotsuke, Japan
| |
Collapse
|
7
|
Kinematics and kinetics comparison of ultra-congruent versus medial-pivot designs for total knee arthroplasty by multibody analysis. Sci Rep 2022; 12:3052. [PMID: 35197496 PMCID: PMC8866513 DOI: 10.1038/s41598-022-06909-x] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2021] [Accepted: 02/08/2022] [Indexed: 12/18/2022] Open
Abstract
Nowadays, several configurations of total knee arthroplasty (TKA) implants are commercially available whose designs resulted from clinical and biomechanical considerations. Previous research activities led to the development of the so-called medial-pivot (MP) design. However, the actual benefits of the MP, with respect to other prosthesis designs, are still not well understood. The present work compares the impact of two insert geometries, namely the ultra-congruent (UC) and medial-pivot (MP), on the biomechanical behaviour of a bicondylar total knee endoprosthesis. For this purpose, a multibody model of a lower limb was created alternatively integrating the two implants having the insert geometry discretized. Joint dynamics and contact pressure distributions were evaluated by simulating a squat motion. Results showed a similar tibial internal rotation range of about 3.5°, but an early rotation occurs for the MP design. Furthermore, the discretization of the insert geometry allowed to efficiently derive the contact pressure distributions, directly within the multibody simulation framework, reporting peak pressure values of 33 MPa and 20 MPa for the UC and MP, respectively. Clinically, the presented findings confirm the possibility, through a MP design, to achieve a more natural joint kinematics, consequently improving the post-operative patient satisfaction and potentially reducing the occurrence of phenomena leading to the insert loosening.
Collapse
|
8
|
Walker PS, Mhadgut A, Buchalter DB, Kirby DJ, Hennessy D. The effect of total knee geometries on kinematics: An experimental study using a crouching machine. J Orthop Res 2021; 39:2537-2545. [PMID: 33713363 DOI: 10.1002/jor.25026] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/08/2020] [Revised: 01/13/2021] [Accepted: 03/10/2021] [Indexed: 02/04/2023]
Abstract
Obtaining anatomic knee kinematics after a total knee is likely to improve outcomes. We used a crouching machine to compare the kinematics of standard condylar designs with guided motion designs. The standard condylars included femoral sagittal radii with constant radius, J-curve and G-curve; the tibial surfaces were of low and high constraint. The guided motion designs were a medial pivot and a design with asymmetric condylar shapes and guiding surfaces. The machine had a flexion range from 0° to 125°, applied quadriceps and hamstring loading, and simulated the collateral soft tissues. The kinematics of all standard condylar knees were similar, showing only small anterior-posterior displacements and internal-external rotations. The two asymmetric designs showed posterior displacements during flexion, but less axial rotations than anatomic knees. The quadriceps forces throughout flexion were very similar between all designs, reflecting similar lever arms. It was concluded that standard condylar designs, even with variations in sagittal radii, are unlikely to reproduce anatomic kinematics. On the other hand, designs with asymmetric constraint between medial and lateral sides, and other guiding features, are likely to be the way forward. The mechanical testing method could be further improved by superimposing shear forces and torques during the flexion-extension motion, to include more stressful in vivo functional conditions.
Collapse
Affiliation(s)
- Peter S Walker
- Department of Orthopedic Surgery, NYU Langone Health, New York, New York, USA
| | - Aishwarya Mhadgut
- Department of Orthopedic Surgery, NYU Langone Health, New York, New York, USA
| | - Daniel B Buchalter
- Department of Orthopedic Surgery, NYU Langone Health, New York, New York, USA
| | - David J Kirby
- Department of Orthopedic Surgery, NYU Langone Health, New York, New York, USA
| | - Daniel Hennessy
- Department of Orthopedic Surgery, NYU Langone Health, New York, New York, USA
| |
Collapse
|
9
|
Khasian M, Meccia BA, LaCour MT, Komistek RD. A Validated Forward Solution Dynamics Mathematical Model of the Knee Joint: Can It Be an Effective Alternative for Implant Evaluation? J Arthroplasty 2020; 35:3289-3299. [PMID: 32631725 DOI: 10.1016/j.arth.2020.06.017] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/15/2020] [Revised: 06/05/2020] [Accepted: 06/09/2020] [Indexed: 02/07/2023] Open
Abstract
BACKGROUND Mathematical modeling is among the most common computational tools for assessing total knee arthroplasty (TKA) mechanics of different implant designs and surgical alignments. The main objective of this study is to describe and validate a forward solution mathematical of the knee joint to investigate the effects of TKA design and surgical conditions on TKA outcomes. METHODS A 12-degree of freedom mathematical model of the human knee was developed. This model includes the whole lower extremity of the human body and comprises major muscles and ligaments at the knee joint. The muscle forces are computed using a proportional-integral-derivative controller, and the joint forces are calculated using a contact detection algorithm. The model was validated using telemetric implants and fluoroscopy, and the sensitivity analyses were performed to determine how sensitive the model is to both implant design, which was analyzed by varying medial conformity of the polyethylene, and surgical alignment, which was analyzed by varying the posterior tibial tilt. RESULTS The model predicted the tibiofemoral joint forces with an average accuracy of 0.14× body weight (BW), 0.13× BW, and 0.17× BW root-mean-square errors for lateral, medial, and total tibiofemoral contact forces. With fluoroscopy, the kinematics were validated with an average accuracy of 0.44 mm, 0.62 mm, and 0.77 root-mean-square errors for lateral anteroposterior position, medial anteroposterior position, and axial rotation, respectively. Increasing medial conformity resulted in reducing the paradoxical anterior sliding midflexion. Furthermore, increasing posterior tibial slopes shifted the femoral contact point more posterior on the bearing and reduced the tension in the posterior cruciate ligament. CONCLUSION A forward solution dynamics model of the knee joint was developed and validated using telemetry devices and fluoroscopy data. The results of this study suggest that a validated mathematical model can be used to predict the effects of component design and surgical conditions on TKA outcomes.
Collapse
Affiliation(s)
- Milad Khasian
- MABE Department, Center for Musculoskeletal Research, University of Tennessee, Knoxville, TN
| | - Bradley A Meccia
- MABE Department, Center for Musculoskeletal Research, University of Tennessee, Knoxville, TN
| | - Michael T LaCour
- MABE Department, Center for Musculoskeletal Research, University of Tennessee, Knoxville, TN
| | - Richard D Komistek
- MABE Department, Center for Musculoskeletal Research, University of Tennessee, Knoxville, TN
| |
Collapse
|
10
|
Gray HA, Guan S, Young TJ, Dowsey MM, Choong PF, Pandy MG. Comparison of posterior-stabilized, cruciate-retaining, and medial-stabilized knee implant motion during gait. J Orthop Res 2020; 38:1753-1768. [PMID: 31994751 DOI: 10.1002/jor.24613] [Citation(s) in RCA: 28] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/08/2019] [Revised: 12/18/2019] [Accepted: 01/21/2020] [Indexed: 02/04/2023]
Abstract
Accurate knowledge of knee joint motion is needed to evaluate the effects of implant design on functional performance and component wear. We conducted a randomized controlled trial to measure and compare 6-degree-of-freedom (6-DOF) kinematics and femoral condylar motion of posterior-stabilized (PS), cruciate-retaining (CR), and medial-stabilized (MS) knee implant designs for one cycle of walking. A mobile biplane X-ray imaging system was used to accurately measure 6-DOF tibiofemoral motion as patients implanted with PS (n = 23), CR (n = 25), or MS (n = 26) knees walked over ground at their self-selected speeds. Knee flexion angle did not differ significantly between the three designs. Relative movements of the femoral and tibial components were generally similar for PS and CR with significant differences observed only for anterior tibial drawer. Knee kinematic profiles measured for MS were appreciably different: external rotation and abduction of the tibia were increased while peak-to-peak anterior drawer was significantly reduced for MS compared with PS and CR. Anterior-posterior drawer and medial-lateral shift of the tibia were strongly coupled to internal-external rotation for MS, as was anterior-posterior translation of the contact center in the lateral compartment. MS exhibited the least amount of paradoxical anterior translation of the femur relative to the tibia during knee flexion. The joint center of rotation in the transverse plane was located in the lateral compartment for PS and CR and in the medial compartment for MS. Substantial differences were evident in 6-DOF knee kinematics between the healthy knee and all three prosthetic designs. Overall, knee kinematic profiles observed for MS resemble those of the healthy joint more closely than PS and CR.
Collapse
Affiliation(s)
- Hans A Gray
- Department of Mechanical Engineering, University of Melbourne, Parkville, Victoria, Australia
| | - Shanyuanye Guan
- Department of Mechanical Engineering, University of Melbourne, Parkville, Victoria, Australia
| | - Tony J Young
- Department of Surgery, St. Vincent's Hospital, University of Melbourne, Fitzroy, Victoria, Australia
- Department of Orthopaedics, St. Vincent's Hospital, Fitzroy, Victoria, Australia
| | - Michelle M Dowsey
- Department of Surgery, St. Vincent's Hospital, University of Melbourne, Fitzroy, Victoria, Australia
- Department of Orthopaedics, St. Vincent's Hospital, Fitzroy, Victoria, Australia
| | - Peter F Choong
- Department of Surgery, St. Vincent's Hospital, University of Melbourne, Fitzroy, Victoria, Australia
- Department of Orthopaedics, St. Vincent's Hospital, Fitzroy, Victoria, Australia
| | - Marcus G Pandy
- Department of Mechanical Engineering, University of Melbourne, Parkville, Victoria, Australia
| |
Collapse
|
11
|
Koh YG, Park KM, Lee HY, Park JH, Kang KT. Prediction of wear performance in femoral and tibial conformity in patient-specific cruciate-retaining total knee arthroplasty. J Orthop Surg Res 2020; 15:24. [PMID: 31969195 PMCID: PMC6977248 DOI: 10.1186/s13018-020-1548-4] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/19/2019] [Accepted: 01/06/2020] [Indexed: 11/14/2022] Open
Abstract
BACKGROUND Articular surface curvature design is important in tibiofemoral kinematics and the contact mechanics of total knee arthroplasty (TKA). Thus far, the effects of articular surface curvature have not been adequately discussed with respect to conforming, nonconforming, and medial pivot designs in patient-specific TKA. Therefore, this study evaluates the underlying relationship between the articular surface curvature geometry and the wear performance in patient-specific TKA. METHODS We compare the wear performances between conventional and patient-specific TKA under gait loading conditions using a computational simulation. Patient-specific TKAs investigated in the study are categorized into patient-specific TKA with conforming articular surfaces, medial pivot patient-specific TKA, and bio-mimetic patient-specific TKA with a patient's own tibial and femoral anatomy. The geometries of the femoral components in patient-specific TKAs are identical. RESULTS The anterior-posterior and internal-external kinematics change with respect to different TKA designs. Moreover, the contact pressure and area did not directly affect the wear performance. In particular, conforming patient-specific TKAs exhibit the highest volumetric wear and wear rate. The volumetric wear in a conforming patient-specific TKA is 29% greater than that in a medial pivot patient-specific TKA. CONCLUSION The findings in this study highlight that conformity changes in the femoral and tibial inserts influence the wear performance in patient-specific TKA. Kinematics and contact parameters should be considered to improve wear performance in patient-specific TKA. The conformity modification in the tibiofemoral joint changes the kinematics and contact parameters, and this affects wear performance.
Collapse
Affiliation(s)
- Yong-Gon Koh
- Joint Reconstruction Center, Department of Orthopaedic Surgery, Yonsei Sarang Hospital, 10 Hyoryeong-ro, Seocho-gu, Seoul, 06698, Republic of Korea
| | - Kyoung-Mi Park
- Department of Mechanical Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea
| | - Hwa-Yong Lee
- Department of Mechanical Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea
| | - Joon-Hee Park
- Department of Anesthesiology & Pain Medicine, Hallym University College of Medicine and Kangdong Sacred Heart Hospital, 150 Seongan-ro, Gangdong-gu, Seoul, 05355, Republic of Korea.
| | - Kyoung-Tak Kang
- Department of Mechanical Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea.
| |
Collapse
|
12
|
Wang L, Wang CJ. Preliminary study of a customised total knee implant with musculoskeletal and dynamic squatting simulation. Proc Inst Mech Eng H 2019; 233:1010-1023. [DOI: 10.1177/0954411919865401] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Customised total knee replacement could be the future therapy for knee joint osteoarthritis. A preliminary design of a customised total knee implant based on knee anatomy was studied in this article. To evaluate its biomechanical performance, a dynamic finite element model based on the Oxford knee rig was created to simulate a squatting motion. Unlike previous research, this dynamic model was simulated with patient-specific muscle and joint loads that were calculated from an OpenSim musculoskeletal model. The dynamic response of the customised total knee implant was simulated under three cruciate ligament scenarios: both cruciate ligaments retained, only anterior cruciate ligament removed and both cruciate ligaments removed. In addition, an off-the-shelf symmetric total knee implant with retained cruciate ligaments was simulated for comparison analysis. The customised total knee implant with both cruciate ligaments retained showed larger ranges of femoral external rotation and posterior translation than the symmetric total knee implant. The motion of the customised total knee implant was also in good agreement with a healthy knee. There were no big differences in the tibiofemoral compressive forces in the customised total knee implant model under the three scenarios. These forces were generally consistent with other experimental and simulation results. However, the customised total knee implant design resulted in larger tibiofemoral compressive force than the symmetric total knee implant after 50° knee flexion, which was caused by the larger tibiofemoral relative motion.
Collapse
Affiliation(s)
- Linjie Wang
- Department of Engineering and Design, University of Sussex, Brighton, UK
| | - Chang Jiang Wang
- Department of Engineering and Design, University of Sussex, Brighton, UK
| |
Collapse
|
13
|
TKA design-integrated trochlea groove rotation reduces patellofemoral pressure. Knee Surg Sports Traumatol Arthrosc 2019; 27:1680-1692. [PMID: 30564858 DOI: 10.1007/s00167-018-5324-5] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/09/2018] [Accepted: 12/07/2018] [Indexed: 01/09/2023]
Abstract
PURPOSE Total knee arthroplasty (TKA) leaves 11-25% of the patients unsatisfied, and patellofemoral joint pain is one cause. This study aimed to compare the differences between kinematics and load transfer in the same knee with axial internal/external rotation of the femoral component (CoRo) versus a separate axial internal/external trochlear groove rotation (TrRo) which is included in the TKA trochlea design. METHODS A validated weight-bearing finite element model with modifications of the TKA axial femoral component rotation (CoRo) and a modified trochlear rotation (TrRo) was calculated and analysed. RESULTS Compared to the neutrally implanted TKA at 105° of flexion, a 6° external rotation of the trochlear groove reduced the retropatellar stress by 7%, whereas a 3° internal trochlear groove rotation increased the retropatellar stress by 7%. With femoral component rotation, the tibia inlay stress of 6.7 MPa at 60° of flexion was two times higher both with a 3° internal component rotation and a 6° external rotation. CONCLUSION These results demonstrate in the tested TKA design that a trochlear groove rotation can reduce retropatellar stress. Additionally, during the TKA operation, the surgeon should be aware of the significant influence of axial femoral component rotation on mechanical inlay stress during flexion and of the fact that even small changes in the patellofemoral joint may influence the tibiofemoral joint. These results support that an external rotation of the femoral component should be preferred in TKA to avoid anterior knee pain. Furthermore, new developed TKA designs should integrate an externally rotated trochlea groove.
Collapse
|
14
|
Koh YG, Son J, Kwon OR, Kwon SK, Kang KT. Tibiofemoral conformity variation offers changed kinematics and wear performance of customized posterior-stabilized total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 2019; 27:1213-1223. [PMID: 29974167 DOI: 10.1007/s00167-018-5045-9] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/16/2018] [Accepted: 06/27/2018] [Indexed: 01/17/2023]
Abstract
PURPOSE Posterior-stabilized (PS)-total knee arthroplasty (TKA) can be applied in any of several variations in terms of the tibiofemoral conformity and post-cam mechanism. However, previous studies have not evaluated the effect of the condylar surface radii (tibiofemoral conformity) on wear in a customized PS-TKA. The present study involved evaluating the wear performance with respect to three different conformities of the tibiofemoral articular surface in a customized PS-TKA by means of a computational simulation. METHODS An adaptive computational simulation method was developed that conduct wear simulation for tibial insert to predict kinematics, weight loss due to wear, and wear contours to results. Wear predictions using computational simulation were performed for 5 million gait cycles with force-controlled inputs. Customized PS-TKA designs were developed and categorized as conventional conformity (CPS-TKA), medial pivot conformity (MPS-TKA), and anatomical conformity (APS-TKA). The post-cam design in the customized PS-TKA is identical. We compared the kinematics, contact mechanics, and wear performance. RESULTS The findings revealed that APS-TKA exhibited the highest internal tibial rotation relative to other TKA designs. Additionally, the higher contact area led to there being less contact stress although it did not directly affect the wear performance. Specifically, MPS-TKA exhibited the lowest volumetric wear. CONCLUSIONS The results of the present study showed that tibiofemoral articular surface conformity should be considered carefully in customized PS-TKA design. Different wear performances were observed with respect to different tibiofemoral conformities. Even though APS-TKA exhibited an inferior wear performance compared to MPS-TKA, it proved to be better in terms of kinematics so its functionality may be improved through the optimization of the tibiofemoral articular surface conformity. Additionally, it should be carefully designed since any changes may affect the post-cam mechanism.
Collapse
Affiliation(s)
- Yong-Gon Koh
- Joint Reconstruction Center, Department of Orthopaedic Surgery, Yonsei Sarang Hospital, 10 Hyoryeong-ro, Seocho-gu, Seoul, 06698, Republic of Korea
| | - Juhyun Son
- Department of Mechanical Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea
| | - Oh-Ryong Kwon
- Joint Reconstruction Center, Department of Orthopaedic Surgery, Yonsei Sarang Hospital, 10 Hyoryeong-ro, Seocho-gu, Seoul, 06698, Republic of Korea
| | - Sae Kwang Kwon
- Joint Reconstruction Center, Department of Orthopaedic Surgery, Yonsei Sarang Hospital, 10 Hyoryeong-ro, Seocho-gu, Seoul, 06698, Republic of Korea
| | - Kyoung-Tak Kang
- Department of Mechanical Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea.
| |
Collapse
|
15
|
Wang XH, Dong X, Zhu BZ, Jiang L, Jin ZM, Suguro T, Cheng CK. A preclinical method for evaluating the kinematics of knee prostheses. Med Eng Phys 2019; 66:84-90. [PMID: 30871881 DOI: 10.1016/j.medengphy.2019.03.003] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2018] [Revised: 02/25/2019] [Accepted: 03/03/2019] [Indexed: 10/27/2022]
Abstract
The primary intent of anatomical knee implants is to replicate the motions of a normal knee joint. In developing such designs, a preclinical evaluation of kinematic behavior is needed. This study introduces an in vitro testing method for recording movements of the knee joint. A novel testing jig was developed and incorporated into a knee simulator setup alongside a motion capture system to directly track the medial and lateral movements of a knee prosthesis. The test system developed in this study required a number of factors to be validated; (i) gait inputs to the knee simulator (result: 0.37-1.575% error), (ii) validity of global coordinate system in the motion capture system, (iii) the position of flexion facet centers (FFCs) detected by the motion capture system (result: a maximum error of 0.08 mm in AP direction and 0.3 mm in SI direction), (iv) local coordinate system in the motion capture system (result: 1.09% error for the measurement of flexion angle), (v) that FFC results were in good agreement with inputs. In conclusion, the system developed in this study for recording FFC is a direct and reliable in vitro test method for analyzing the kinematics of a knee prosthesis.
Collapse
Affiliation(s)
- Xiao-Hong Wang
- School of Biological Science and Medical Engineering, Beihang University, No. 37, XueYuan Road, HaiDian District, Beijing 100083, China.
| | - Xiang Dong
- Beijing Medical Implant Engineering Research Center, Beijing Naton Technology Group Co. LTD, Beijing 100082, China; Beijing Engineering Laboratory of Functional Medical Materials and Devices, Beijing Naton Technology Group Co. LTD, Beijing 100082, China.
| | - Bao-Zhang Zhu
- Beijing Medical Implant Engineering Research Center, Beijing Naton Technology Group Co. LTD, Beijing 100082, China; Beijing Engineering Laboratory of Functional Medical Materials and Devices, Beijing Naton Technology Group Co. LTD, Beijing 100082, China.
| | - Lei Jiang
- Beijing Medical Implant Engineering Research Center, Beijing Naton Technology Group Co. LTD, Beijing 100082, China; Beijing Engineering Laboratory of Functional Medical Materials and Devices, Beijing Naton Technology Group Co. LTD, Beijing 100082, China.
| | - Zhong-Min Jin
- Institute of Tribology, School of Mechanical Engineering, Southwest Jiaotong University, Chengdu 610031, China.
| | - Toru Suguro
- Japan Research Institute of Artificial Joint, Research Institute of Rheumatology Medical Treatment, Tokyo 104-0032, Japan.
| | - Cheng-Kung Cheng
- School of Biological Science and Medical Engineering, Beihang University, No. 37, XueYuan Road, HaiDian District, Beijing 100083, China; Beijing Advanced Innovation Center for Biomedical Engineering, Beihang University, Beijing 100083, China.
| |
Collapse
|
16
|
Koh YG, Nam JH, Kang KT. Effect of geometric variations on tibiofemoral surface and post-cam design of normal knee kinematics restoration. J Exp Orthop 2018; 5:53. [PMID: 30578465 PMCID: PMC6303222 DOI: 10.1186/s40634-018-0167-z] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/18/2018] [Accepted: 11/29/2018] [Indexed: 11/29/2022] Open
Abstract
Background Restoration of natural knee kinematics for a designed mechanism in knee implants is required to achieve full knee function in total knee arthroplasty (TKA). In different posterior-stabilized TKAs, there are wide variations in tibiofemoral surfaces and post-cam design. However, it is not known whether these design variations preserve natural knee kinematics. The purpose of this study was to determine the most appropriate tibiofemoral surface and post-cam designs to restore natural knee kinematics of the TKA. Methods A subject-specific finite element knee modal was used to evaluate tibiofemoral surface and post-cam design. Three different posts in convex, straight, and concave geometries were considered with a fixed circular cam design in this study. In addition, this post-cam design was applied to three different surface conformities for conforming, medial pivot, and subject anatomy mimetic tibiofemoral surfaces. We evaluated the femoral rollback, internal-external rotation, and quadriceps muscle force under a deep-knee-bend condition. Results The three different tibiofemoral conformities showed that the convex post provided the most natural-knee-like femoral rollback. This was also observed in internal rotation. In surface conformity, subject anatomy mimetic tibiofemoral surfaces showed the most natural -knee-like kinematics and quadriceps force. Conclusions This study confirmed that convex post design and subject anatomy mimetic tibiofemoral surfaces provided the most natural-knee-like kinematics. This study suggested that post-cam design and tibiofemoral surface conformity should be considered in conventional and customized TKA.
Collapse
Affiliation(s)
- Yong-Gon Koh
- Joint Reconstruction Center, Department of Orthopaedic Surgery, Yonsei Sarang Hospital, 10 Hyoryeong-ro, Seocho-gu, Seoul, 06698, Republic of Korea
| | - Ji-Hoon Nam
- Department of Mechanical Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea
| | - Kyoung-Tak Kang
- Department of Mechanical Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea.
| |
Collapse
|
17
|
Koh YG, Lee JA, Chung PK, Kang KT. Computational analysis of customized cruciate retaining total knee arthroplasty restoration of native knee joint biomechanics. Artif Organs 2018; 43:504-514. [PMID: 30375662 DOI: 10.1111/aor.13382] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2018] [Revised: 10/17/2018] [Accepted: 10/25/2018] [Indexed: 01/20/2023]
Abstract
The purpose of this study was to verify if customized prosthesis better preserves the native knee joint kinematics and provides lower contact stress on the polyethylene (PE) insert owing to the wider bone preservation than that of standard off-the-shelf prosthesis in posterior cruciate-retaining type total knee arthroplasty (TKA). Validated finite element (FE) models for were developed to evaluate the knee joint kinematics and contact stress on the PE insert after TKA with customized and standard off-the-shelf (OTS) prostheses as well as in normal healthy knee through FE analysis under dynamic loading conditions. The contact stresses on the customized prosthesis decreased by 18% and 8% under gait cycle loading conditions, and 24% and 9% under deep-knee-bend loading conditions, in the medial and lateral sides of the PE insert, respectively, compared with the standard OTS prosthesis. The anterior-posterior translation and internal-external (IE) rotation in customized TKA were more similar to native knee joint behaviors compared with standard OTS TKA under gait loading conditions. The difference from normal knee kinematics was lower for femoral rollback and IE rotation in customized TKA than in standard OTS TKA in the deep-knee-bend condition. In general, customized prostheses achieve kinematics that are close to those of the native healthy knee joint and have better contact stresses than standard OTS prostheses in gait and deep-knee-bend loading conditions.
Collapse
Affiliation(s)
- Yong-Gon Koh
- Joint Reconstruction Center, Department of Orthopaedic Surgery, Yonsei Sarang Hospital, Seoul, Republic of Korea
| | - Jin-Ah Lee
- Department of Mechanical Engineering, Yonsei University, Seoul, Republic of Korea
| | - Pill Ku Chung
- Joint Reconstruction Center, Department of Orthopaedic Surgery, Yonsei Sarang Hospital, Seoul, Republic of Korea
| | - Kyoung-Tak Kang
- Department of Mechanical Engineering, Yonsei University, Seoul, Republic of Korea
| |
Collapse
|
18
|
Twiggs JG, Wakelin EA, Roe JP, Dickison DM, Fritsch BA, Miles BP, Ruys AJ. Patient-Specific Simulated Dynamics After Total Knee Arthroplasty Correlate With Patient-Reported Outcomes. J Arthroplasty 2018; 33:2843-2850. [PMID: 29807792 DOI: 10.1016/j.arth.2018.04.035] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/22/2018] [Revised: 04/16/2018] [Accepted: 04/20/2018] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Component alignment variation following total knee arthroplasty (TKA) does not fully explain the instance of long-term postoperative pain. Joint dynamics following TKA vary with component alignment and patient-specific musculoskeletal anatomy. Computational simulations allow joint dynamics outcomes to be studied across populations. This study aims to determine if simulated postoperative TKA joint dynamics correlate with patient-reported outcomes. METHODS Landmarking and 3D registration of implants was performed on 96 segmented postoperative computed tomography scans of TKAs. A cadaver rig-validated platform for generating patient-specific simulation of deep knee bend kinematics was run for each patient. Resultant dynamic outcomes were correlated with a 12-month postoperative Knee Injury and Osteoarthritis Outcome Score (KOOS). A Classification and Regression Tree (CART) was used for determining nonlinear relationships. RESULTS Nonlinear relationships between the KOOS pain score and rollback and dynamic coronal alignment were found to be significant. Combining a dynamic coronal angular change from extension to full flexion between 0° and 4° varus (long leg axis) and measured rollback of no more than 6 mm without rollforward formed a "kinematic safe zone" of outcomes in which the postoperative KOOS score is 10.5 points higher (P = .013). CONCLUSION The study showed statistically significant correlations between kinematic factors in a simulation of postoperative TKA and postoperative KOOS scores. The presence of a dynamic safe zone in the data suggests a potential optimal target for any given individual patient's joint dynamics and the opportunity to preoperatively determine a patient-specific alignment target to achieve those joint dynamics.
Collapse
Affiliation(s)
- Joshua G Twiggs
- 360 Knee Systems, Sydney, Australia; Department of Biomedical Engineering, University of Sydney, Sydney, Australia
| | | | - Justin P Roe
- North Sydney Orthopaedic and Sports Medicine Centre, The Mater Hospital, North Sydney, Australia
| | | | | | | | - Andrew J Ruys
- Department of Biomedical Engineering, University of Sydney, Sydney, Australia
| |
Collapse
|
19
|
Galvin CR, Perriman DM, Newman PM, Lynch JT, Smith PN, Scarvell JM. Squatting, lunging and kneeling provided similar kinematic profiles in healthy knees-A systematic review and meta-analysis of the literature on deep knee flexion kinematics. Knee 2018; 25:514-530. [PMID: 29802075 DOI: 10.1016/j.knee.2018.04.015] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/20/2017] [Revised: 03/20/2018] [Accepted: 04/29/2018] [Indexed: 02/02/2023]
Abstract
BACKGROUND Understanding healthy deep flexion kinematics will inform the design of conservative clinical rehabilitation strategies for knee osteoarthritis and contribute to improved knee prosthesis design. This study is a systematic review and meta-analysis of the kinematic outcomes measured at the healthy tibiofemoral joint during loaded deep knee flexion. METHODS A computerised literature search and bibliography review without date restriction identified twelve studies with 164 participants aged 25-61 years in-vivo, and 69-93 years in-vitro. Flexion higher than 120° was achieved by squatting, lunging or kneeling. Measurement technologies in-vivo included radiographs, open MRI and 2D-3D MRI or CT image registration on fluoroscopy. Microscribe was used in-vitro. RESULTS Outcomes were either six degrees-of-freedom based on femur movement or contact patterns on the tibial plateau. The meta-analysis demonstrated that in-vivo, between 120° and 135° of flexion, the tibia internally rotated (mean difference (MD) = 4.6°, 95% CI 3.55° to 5.64°). Both the medial-femoral-condyle and lateral-femoral-condyle translated posteriorly, (MD = 10.4 mm, 95% CI 6.9 to 13.9 mm) and (MD = 5.55 mm, 95% CI 4.64 to 6.46 mm) respectively. There was some evidence of femoral medial translation (3.8 mm) and adduction (1.9° to 3.3°), together with medial compression (1.7 mm) and lateral distraction (1.9) mm. CONCLUSIONS Across the in-vivo studies, consistent kinematic patterns emerged; despite the various measurement technologies and reference methods. In contrast, in-vivo and in-vitro results were contradictory. TRIAL REGISTRATION This systematic review protocol was registered with the International Prospective Register of Systematic Reviews (PROSPERO) on 25 February 2017 (registration number: 42017057614).
Collapse
Affiliation(s)
- Catherine R Galvin
- Faculty of Health, University of Canberra, Locked Bag 1, 2601, Australia; Trauma and Orthopaedic Research Unit, Canberra Hospital, Garran, ACT, 2605, Australia.
| | - Diana M Perriman
- Faculty of Health, University of Canberra, Locked Bag 1, 2601, Australia; The Australian National University, Acton, ACT 2601, Australia; Trauma and Orthopaedic Research Unit, Canberra Hospital, Garran, ACT, 2605, Australia.
| | - Phillip M Newman
- Faculty of Health, University of Canberra, Locked Bag 1, 2601, Australia; University of Canberra Research Institute for Sport and Exercise (UCRISE).
| | - Joseph T Lynch
- The Australian National University, Acton, ACT 2601, Australia; Trauma and Orthopaedic Research Unit, Canberra Hospital, Garran, ACT, 2605, Australia.
| | - Paul N Smith
- The Australian National University, Acton, ACT 2601, Australia; Trauma and Orthopaedic Research Unit, Canberra Hospital, Garran, ACT, 2605, Australia.
| | - Jennie M Scarvell
- Faculty of Health, University of Canberra, Locked Bag 1, 2601, Australia; Trauma and Orthopaedic Research Unit, Canberra Hospital, Garran, ACT, 2605, Australia.
| |
Collapse
|
20
|
Zumbrunn T, Duffy MP, Rubash HE, Malchau H, Muratoglu OK, Varadarajan KM. ACL substitution may improve kinematics of PCL-retaining total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 2018; 26:1445-1454. [PMID: 27837219 DOI: 10.1007/s00167-016-4372-y] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/26/2016] [Accepted: 10/25/2016] [Indexed: 10/20/2022]
Abstract
PURPOSE One of the key factors responsible for altered kinematics and joint stability following contemporary total knee arthroplasty (TKA) is resection of the anterior cruciate ligament (ACL). However, ACL retention can present several technical challenges, and in some cases may not be viable due to an absent or nonfunctional ACL. Therefore, the goal of this research was to investigate whether substitution of the ACL through an anterior post mechanism could improve kinematic deficits of contemporary posterior cruciate ligament (PCL) retaining implants. METHODS Kinematic analysis of different implant types was done using KneeSIM, a previously established dynamic simulation tool. Walking, stair-ascent, chair-sit, and deep knee bend were simulated for an ACL-substituting (PCL-retaining) design, a bi-cruciate-retaining and ACL-sacrificing (PCL-retaining) implant, as well as the native knee. The motion of the femoral condyles relative to the tibia was recorded for kinematic comparisons. RESULTS The ACL-substituting and ACL-retaining implants provided similar kinematic improvements over the ACL-sacrificing implant, by reducing posterior femoral shift in extension and preventing paradoxical anterior sliding. During all simulated activities, the ACL-sacrificing implant showed between 7 and 8 mm of posterior shift in extension in contrast to the ACL-retaining implant and the ACL-substituting design, which showed overall kinematic trends similar to the native knee. CONCLUSION The absence of ACL function has been linked to abnormal kinematics and joint stability in patients with contemporary TKA. ACL-substituting implants could be a valuable treatment option capable of overcoming the limitations of contemporary TKA, particularly when retaining the native ACL is not feasible or is challenging.
Collapse
Affiliation(s)
- Thomas Zumbrunn
- Department of Orthopaedic Surgery, Technology Implementation Research Center, Massachusetts General Hospital, 55 Fruit St, GRJ-1223, Boston, MA, 02114, USA.,Institute for Biomechanics, ETH Zurich, Hönggerbergring 64, 8093, Zurich, Switzerland
| | - Michael P Duffy
- Department of Orthopaedic Surgery, Technology Implementation Research Center, Massachusetts General Hospital, 55 Fruit St, GRJ-1223, Boston, MA, 02114, USA
| | - Harry E Rubash
- Department of Orthopaedic Surgery, Technology Implementation Research Center, Massachusetts General Hospital, 55 Fruit St, GRJ-1223, Boston, MA, 02114, USA
| | - Henrik Malchau
- Department of Orthopaedic Surgery, Technology Implementation Research Center, Massachusetts General Hospital, 55 Fruit St, GRJ-1223, Boston, MA, 02114, USA
| | - Orhun K Muratoglu
- Department of Orthopaedic Surgery, Technology Implementation Research Center, Massachusetts General Hospital, 55 Fruit St, GRJ-1223, Boston, MA, 02114, USA
| | - Kartik Mangudi Varadarajan
- Department of Orthopaedic Surgery, Technology Implementation Research Center, Massachusetts General Hospital, 55 Fruit St, GRJ-1223, Boston, MA, 02114, USA.
| |
Collapse
|
21
|
Pejhan S, Bohm E, Brandt JM, Gascoyne T, Wyss U. Kinematic behavior of a customized surface-guided knee implant during simulated knee-bending. Med Eng Phys 2017; 48:168-175. [DOI: 10.1016/j.medengphy.2017.06.018] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2016] [Revised: 06/07/2017] [Accepted: 06/14/2017] [Indexed: 11/27/2022]
|
22
|
Koh YG, Son J, Kwon SK, Kim HJ, Kwon OR, Kang KT. Preservation of kinematics with posterior cruciate-, bicruciate- and patient-specific bicruciate-retaining prostheses in total knee arthroplasty by using computational simulation with normal knee model. Bone Joint Res 2017; 6:557-565. [PMID: 28947604 PMCID: PMC5631000 DOI: 10.1302/2046-3758.69.bjr-2016-0250.r1] [Citation(s) in RCA: 30] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/26/2016] [Accepted: 06/30/2017] [Indexed: 12/11/2022] Open
Abstract
Objectives Preservation of both anterior and posterior cruciate ligaments in total knee arthroplasty (TKA) can lead to near-normal post-operative joint mechanics and improved knee function. We hypothesised that a patient-specific bicruciate-retaining prosthesis preserves near-normal kinematics better than standard off-the-shelf posterior cruciate-retaining and bicruciate-retaining prostheses in TKA. Methods We developed the validated models to evaluate the post-operative kinematics in patient-specific bicruciate-retaining, standard off-the-shelf bicruciate-retaining and posterior cruciate-retaining TKA under gait and deep knee bend loading conditions using numerical simulation. Results Tibial posterior translation and internal rotation in patient-specific bicruciate-retaining prostheses preserved near-normal kinematics better than other standard off-the-shelf prostheses under gait loading conditions. Differences from normal kinematics were minimised for femoral rollback and internal-external rotation in patient-specific bicruciate-retaining, followed by standard off-the-shelf bicruciate-retaining and posterior cruciate-retaining TKA under deep knee bend loading conditions. Moreover, the standard off-the-shelf posterior cruciate-retaining TKA in this study showed the most abnormal performance in kinematics under gait and deep knee bend loading conditions, whereas patient-specific bicruciate-retaining TKA led to near-normal kinematics. Conclusion This study showed that restoration of the normal geometry of the knee joint in patient-specific bicruciate-retaining TKA and preservation of the anterior cruciate ligament can lead to improvement in kinematics compared with the standard off-the-shelf posterior cruciate-retaining and bicruciate-retaining TKA. Cite this article: Y-G. Koh, J. Son, S-K. Kwon, H-J. Kim, O-R. Kwon, K-T. Kang. Preservation of kinematics with posterior cruciate-, bicruciate- and patient-specific bicruciate-retaining prostheses in total knee arthroplasty by using computational simulation with normal knee model. Bone Joint Res 2017;6:557–565. DOI: 10.1302/2046-3758.69.BJR-2016-0250.R1.
Collapse
Affiliation(s)
- Y-G Koh
- Joint Reconstruction Center, Department of Orthopaedic Surgery, Yonsei Sarang Hospital, 10 Hyoryeong-ro, Seocho-gu, Seoul 06698, South Korea
| | - J Son
- Department of Mechanical Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul, 03722, South Korea
| | - S-K Kwon
- Joint Reconstruction Center, Department of Orthopaedic Surgery, Yonsei Sarang Hospital, 10 Hyoryeong-ro, Seocho-gu, Seoul 06698, South Korea
| | - H-J Kim
- Spine Center and Department of Orthopaedic Surgery, Seoul National University College of Medicine and Seoul National University Bundang Hospital, 82 Gumi-ro 173 Beongil, Bundang-gu, Seongnam-si, Gyeonggi-do 13620, South Korea
| | - O-R Kwon
- Joint Reconstruction Center, Department of Orthopaedic Surgery, Yonsei Sarang Hospital, 10 Hyoryeong-ro, Seocho-gu, Seoul 06698, South Korea
| | - K-T Kang
- Department of Mechanical Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul, 03722, South Korea
| |
Collapse
|
23
|
Validation of a new computational 6-DOF knee simulator during dynamic activities. J Biomech 2016; 49:3177-3184. [DOI: 10.1016/j.jbiomech.2016.07.040] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2016] [Revised: 06/25/2016] [Accepted: 07/28/2016] [Indexed: 11/18/2022]
|
24
|
Luzi L, Sancisi N, Conconi M, Parenti-Castelli V. A New Test Rig for Human Joint and Prosthesis Characterization1. J Med Device 2016. [DOI: 10.1115/1.4033241] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022] Open
Affiliation(s)
- Luca Luzi
- Department of Industrial Engineering, University of Bologna, Bologna 40136, Italy
| | - Nicola Sancisi
- Department of Industrial Engineering, Health Sciences and Technologies Interdepartmental Centre for Industrial Research, University of Bologna, Bologna 40136, Italy
| | - Michele Conconi
- Department of Industrial Engineering, Health Sciences and Technologies Interdepartmental Centre for Industrial Research, University of Bologna, Bologna 40136, Italy
| | - Vincenzo Parenti-Castelli
- Department of Industrial Engineering, Health Sciences and Technologies Interdepartmental Centre for Industrial Research, University of Bologna, Bologna 40136, Italy
| |
Collapse
|
25
|
Steinbrück A, Schröder C, Woiczinski M, Fottner A, Pinskerova V, Müller PE, Jansson V. Femorotibial kinematics and load patterns after total knee arthroplasty: An in vitro comparison of posterior-stabilized versus medial-stabilized design. Clin Biomech (Bristol, Avon) 2016; 33:42-48. [PMID: 26945720 DOI: 10.1016/j.clinbiomech.2016.02.002] [Citation(s) in RCA: 45] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/03/2015] [Revised: 11/02/2015] [Accepted: 02/09/2016] [Indexed: 02/07/2023]
Abstract
BACKGROUND Femorotibial kinematics and contact patterns vary greatly with different total knee arthroplasty (TKA) designs. Therefore, guided motion knee systems were developed to restore natural knee kinematics and make them more predictable. The medial stabilized TKA design is supposed to replicate physiological kinematics more than the posterior-stabilized TKA system. We conducted this study to compare a newly developed medial stabilized design with a conventional posterior-stabilized design in terms of femorotibial kinematics and contact patterns in vitro. METHODS Twelve fresh-frozen knee specimens were tested in a weight-bearing knee rig after implantation of a posterior stabilized and medial-stabilized total knee arthroplasty under a loaded squat from 20° to 120° of flexion. Femorotibial joint contact pressures in the medial and lateral compartments were measured by pressure sensitive films and knee kinematics were recorded by an ultrasonic 3-dimensional motion analysis system. FINDINGS The medial stabilized design showed a reduction of medial femorotibial translation compared to posterior-stabilized design (mean 3.5mm compared to 15.7 mm, P<0.01). In the lateral compartment, both designs showed a posterior translation of the femur with flexion, but less in the medial stabilized design (mean 14.7 mm compared to 19.0mm, P<0.01). In the medial femorotibial compartment of medial stabilized design, we observed an enlarged contact area and lower peak pressure, in contrast in the lateral compartment there was a reduced contact area and an increased peak pressure. INTERPRETATION While posterior-stabilized design enforces a medio-lateral posterior translation, the medial stabilized arthroplasty system enables a combination of a lateral translation with a medial pivot, which restores the physiological knee kinematics better.
Collapse
Affiliation(s)
- Arnd Steinbrück
- Department of Orthopedic Surgery, Physical Medicine and Rehabilitation, University Hospital of Munich (LMU), Campus Grosshadern, Marchioninistr, 15, 81377 Munich, Germany.
| | - Christian Schröder
- Department of Orthopedic Surgery, Physical Medicine and Rehabilitation, University Hospital of Munich (LMU), Campus Grosshadern, Marchioninistr, 15, 81377 Munich, Germany
| | - Matthias Woiczinski
- Department of Orthopedic Surgery, Physical Medicine and Rehabilitation, University Hospital of Munich (LMU), Campus Grosshadern, Marchioninistr, 15, 81377 Munich, Germany
| | - Andreas Fottner
- Department of Orthopedic Surgery, Physical Medicine and Rehabilitation, University Hospital of Munich (LMU), Campus Grosshadern, Marchioninistr, 15, 81377 Munich, Germany
| | - Vera Pinskerova
- 1st Orthopaedic Clinic, 1st Medical Faculty, Charles University, Prague, Czech Republic
| | - Peter E Müller
- Department of Orthopedic Surgery, Physical Medicine and Rehabilitation, University Hospital of Munich (LMU), Campus Grosshadern, Marchioninistr, 15, 81377 Munich, Germany
| | - Volkmar Jansson
- Department of Orthopedic Surgery, Physical Medicine and Rehabilitation, University Hospital of Munich (LMU), Campus Grosshadern, Marchioninistr, 15, 81377 Munich, Germany
| |
Collapse
|
26
|
Lowry M, Rosenbaum H, Walker PS. Evaluation of total knee mechanics using a crouching simulator with a synthetic knee substitute. Proc Inst Mech Eng H 2016; 230:421-8. [PMID: 26802075 DOI: 10.1177/0954411915626944] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2015] [Accepted: 12/21/2015] [Indexed: 11/17/2022]
Abstract
Mechanical evaluation of total knees is frequently required for aspects such as wear, strength, kinematics, contact areas, and force transmission. In order to carry out such tests, we developed a crouching simulator, based on the Oxford-type machine, with novel features including a synthetic knee including ligaments. The instrumentation and data processing methods enabled the determination of contact area locations and interface forces and moments, for a full flexion-extension cycle. To demonstrate the use of the simulator, we carried out a comparison of two different total knee designs, cruciate retaining and substituting. The first part of the study describes the simulator design and the methodology for testing the knees without requiring cadaveric knee specimens. The degrees of freedom of the anatomic hip and ankle joints were reproduced. Flexion-extension was obtained by changing quadriceps length, while variable hamstring forces were applied using springs. The knee joint was represented by three-dimensional printed blocks on to which the total knee components were fixed. Pretensioned elastomeric bands of realistic stiffnesses passed through holes in the block at anatomical locations to represent ligaments. Motion capture of the knees during flexion, together with laser scanning and computer modeling, was used to reconstruct contact areas on the bearing surfaces. A method was also developed for measuring tibial component interface forces and moments as a comparative assessment of fixation. The method involved interposing Tekscan pads at locations on the interface. Overall, the crouching machine and the methodology could be used for many different mechanical measurements of total knee designs, adapted especially for comparative or parametric studies.
Collapse
Affiliation(s)
- Michael Lowry
- Laboratory for Orthopaedic Implant Design, New York University Hospital for Joint Diseases, New York, NY, USA
| | - Heather Rosenbaum
- Laboratory for Orthopaedic Implant Design, New York University Hospital for Joint Diseases, New York, NY, USA
| | - Peter S Walker
- Laboratory for Orthopaedic Implant Design, New York University Hospital for Joint Diseases, New York, NY, USA
| |
Collapse
|
27
|
Varadarajan KMM, Zumbrunn T, Rubash HE, Malchau H, Li G, Muratoglu OK. Cruciate Retaining Implant With Biomimetic Articular Surface to Reproduce Activity Dependent Kinematics of the Normal Knee. J Arthroplasty 2015; 30:2149-53.e2. [PMID: 26154569 DOI: 10.1016/j.arth.2015.06.018] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/09/2015] [Revised: 05/18/2015] [Accepted: 06/08/2015] [Indexed: 02/01/2023] Open
Abstract
Alterations in normal knee kinematics following total knee arthroplasty (TKA) arise in part from the non-anatomic articular geometry of contemporary implants. In this study, the kinematics of a novel posterior cruciate-retaining (CR) implant with anatomic (biomimetic) articular surface, were compared to that of contemporary CR implants during various simulated activities. Across different simulated activities the biomimetic-CR mimicked normal kinematic patterns more closely than contemporary CR implants. In particular, during deep knee bend and chair-sit, the biomimetic-CR showed medial pivot motion, while other CR implants showed abnormal motion including lateral pivot or no pivot, and paradoxical anterior sliding. Further in vivo and clinical studies are needed to determine whether such biomimetic implants can truly help to achieve a more normal feeling knee and improved patient satisfaction.
Collapse
Affiliation(s)
- Kartik Mangudi M Varadarajan
- Technology Implementation Research Center, Department of Orthopaedic Surgery, Massachusetts General Hospital, Boston, Massachusetts
| | - Thomas Zumbrunn
- Technology Implementation Research Center, Department of Orthopaedic Surgery, Massachusetts General Hospital, Boston, Massachusetts
| | - Harry E Rubash
- Technology Implementation Research Center, Department of Orthopaedic Surgery, Massachusetts General Hospital, Boston, Massachusetts
| | - Henrik Malchau
- Technology Implementation Research Center, Department of Orthopaedic Surgery, Massachusetts General Hospital, Boston, Massachusetts
| | - Guoan Li
- Bioengineering Laboratory, Department of Orthopaedic Surgery, Massachusetts General Hospital, Boston, Massachusetts
| | - Orhun K Muratoglu
- Technology Implementation Research Center, Department of Orthopaedic Surgery, Massachusetts General Hospital, Boston, Massachusetts
| |
Collapse
|
28
|
Woiczinski M, Steinbrück A, Weber P, Müller PE, Jansson V, Schröder C. Development and validation of a weight-bearing finite element model for total knee replacement. Comput Methods Biomech Biomed Engin 2015; 19:1033-45. [PMID: 26618541 DOI: 10.1080/10255842.2015.1089534] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
Total knee arthroplasty (TKA) is a successful procedure for osteoarthritis. However, some patients (19%) do have pain after surgery. A finite element model was developed based on boundary conditions of a knee rig. A 3D-model of an anatomical full leg was generated from magnetic resonance image data and a total knee prosthesis was implanted without patella resurfacing. In the finite element model, a restarting procedure was programmed in order to hold the ground reaction force constant with an adapted quadriceps muscle force during a squat from 20° to 105° of flexion. Knee rig experimental data were used to validate the numerical model in the patellofemoral and femorotibial joint. Furthermore, sensitivity analyses of Young's modulus of the patella cartilage, posterior cruciate ligament (PCL) stiffness, and patella tendon origin were performed. Pearson's correlations for retropatellar contact area, pressure, patella flexion, and femorotibial ap-movement were near to 1. Lowest root mean square error for retropatellar pressure, patella flexion, and femorotibial ap-movement were found for the baseline model setup with Young's modulus of 5 MPa for patella cartilage, a downscaled PCL stiffness of 25% compared to the literature given value and an anatomical origin of the patella tendon. The results of the conducted finite element model are comparable with the experimental results. Therefore, the finite element model developed in this study can be used for further clinical investigations and will help to better understand the clinical aspects after TKA with an unresurfaced patella.
Collapse
Affiliation(s)
- M Woiczinski
- a Department of Orthopedic Surgery, Physical Medicine and Rehabilitation , University Hospital of Munich (LMU) , Munich , Germany
| | - A Steinbrück
- a Department of Orthopedic Surgery, Physical Medicine and Rehabilitation , University Hospital of Munich (LMU) , Munich , Germany
| | - P Weber
- a Department of Orthopedic Surgery, Physical Medicine and Rehabilitation , University Hospital of Munich (LMU) , Munich , Germany
| | - P E Müller
- a Department of Orthopedic Surgery, Physical Medicine and Rehabilitation , University Hospital of Munich (LMU) , Munich , Germany
| | - V Jansson
- a Department of Orthopedic Surgery, Physical Medicine and Rehabilitation , University Hospital of Munich (LMU) , Munich , Germany
| | - Ch Schröder
- a Department of Orthopedic Surgery, Physical Medicine and Rehabilitation , University Hospital of Munich (LMU) , Munich , Germany
| |
Collapse
|
29
|
Walker PS, Arno S, Borukhoy I, Bell CP. Characterising knee motion and laxity in a testing machine for application to total knee evaluation. J Biomech 2015; 48:3551-8. [DOI: 10.1016/j.jbiomech.2015.06.013] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2014] [Revised: 06/15/2015] [Accepted: 06/17/2015] [Indexed: 11/28/2022]
|
30
|
Verstraete MA, Victor J. Possibilities and limitations of novel in-vitro knee simulator. J Biomech 2015; 48:3377-82. [DOI: 10.1016/j.jbiomech.2015.06.007] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2015] [Revised: 05/14/2015] [Accepted: 06/15/2015] [Indexed: 10/23/2022]
|
31
|
Walker PS. The design and pre-clinical evaluation of knee replacements for osteoarthritis. J Biomech 2015; 48:742-9. [DOI: 10.1016/j.jbiomech.2014.12.012] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/26/2014] [Indexed: 10/24/2022]
|
32
|
Baker KM, Foutz TL, Johnsen KJ, Budsberg SC. Effects of tibial plateau angle and spacer thickness applied during in vitro canine total knee replacement on three-dimensional kinematics and collateral ligament strain. Am J Vet Res 2014; 75:792-9. [DOI: 10.2460/ajvr.75.9.792] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
33
|
Application of a novel design method for knee replacements to achieve normal mechanics. Knee 2014; 21:353-8. [PMID: 23141366 DOI: 10.1016/j.knee.2012.08.001] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/11/2012] [Revised: 08/01/2012] [Accepted: 08/13/2012] [Indexed: 02/02/2023]
Abstract
PURPOSE The purpose of this study was to utilize a novel method for the design of total knee replacements for use in the absence of the cruciate ligaments, with the design criteria of reproducing the medial stability and lateral mobility characteristics of the normal anatomic knee. SCOPE The starting point was a femoral component with surfaces approximating anatomic. This surface was moved into multiple positions describing a neutral path of motion and laxity about the neutral path. The distal part of the femoral composite was then used to define the tibial surface. By varying the femoral design, different tibial surfaces were produced. The reference design featured a dished medial tibial surface and a shallow lateral tibial surface, but this provided limited motion guidance. To provide further guidance, two types of design were generated, one using intercondylar guide surfaces, the other providing guidance from the condylar surfaces themselves. CONCLUSIONS The design method was capable of generating a range of total knee surfaces which could potentially return the arthritic knee to more normal function.
Collapse
|
34
|
The effect of geometric variations in posterior-stabilized knee designs on motion characteristics measured in a knee loading machine. Clin Orthop Relat Res 2014; 472:238-47. [PMID: 23917990 PMCID: PMC3889438 DOI: 10.1007/s11999-013-3088-2] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND In different posterior-stabilized (PS) total knees, there are considerable variations in condylar surface radii and cam-post geometry. To what extent these variations affect kinematics is not known. Furthermore, there are no clearly defined ideal kinematics for a total knee. QUESTIONS/PURPOSES The purposes of this study were to determine (1) what the kinematic differences are caused by geometrical variations between PS total knee designs in use today; and (2) what design characteristics will produce kinematics that closely resemble that of the normal anatomic knee. METHODS Four current PS designs with different geometries and one experimental asymmetric PS design, with a relatively conforming medial side, were tested in a purpose-built machine. The machine applied combinations of compressive, shear, and torque forces at a sequence of flexion angles to represent a range of everyday activities, consistent with the ASTM standard test for measuring constraint. The femorotibial contact points, the neutral path of motion, and the AP and internal-external laxities were used as the kinematic indicators. RESULTS The PS designs showed major differences in motion characteristics among themselves and with motion data from anatomic knees determined in a previous study. Abnormalities in the current designs included symmetric mediolateral motion, susceptibility to excessive AP medial laxity, and reduced laxity in high flexion. The asymmetric-guided motion design alleviated some but not all of the abnormalities. CONCLUSIONS Current PS designs showed kinematic abnormalities to a greater or lesser extent. An asymmetric design may provide a path to achieving a closer match to anatomic kinematics. CLINICAL RELEVANCE One criterion for the evaluation of PS total knees is how closely the kinematics of the prosthesis resemble that of the anatomic knee, because this is likely to affect the quality of function.
Collapse
|
35
|
Wünschel M, Leasure JM, Dalheimer P, Kraft N, Wülker N, Müller O. Differences in knee joint kinematics and forces after posterior cruciate retaining and stabilized total knee arthroplasty. Knee 2013; 20:416-21. [PMID: 23578828 DOI: 10.1016/j.knee.2013.03.005] [Citation(s) in RCA: 38] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/02/2012] [Revised: 02/24/2013] [Accepted: 03/06/2013] [Indexed: 02/02/2023]
Abstract
BACKGROUND Posterior cruciate ligament (PCL) retaining (CR) and -sacrificing (PS) total knee arthroplasties (TKA) are widely-used to treat osteoarthritis of the knee joint. The PS design substitutes the function of the PCL with a cam-spine mechanism which may produce adverse changes to joint kinematics and kinetics. METHODS CR- and PS-TKA were performed on 11 human knee specimens. Joint kinematics were measured with a dynamic knee simulator and motion tracking equipment. In-situ loads of the PCL and cam-spine were measured with a robotic force sensor system. Partial weight bearing flexions were simulated and external forces were applied. RESULTS The PS-TKA rotated significantly less throughout the whole flexion range compared to the CR-TKA. Femoral roll back was greater in the PS-TKA; however, this was not correlated with lower quadriceps forces. Application of external loads produced significantly different in-situ force profiles between the TKA systems. CONCLUSIONS Our data demonstrate that the PS-design significantly alters kinematics of the knee joint. Our data also suggest the cam-spine mechanism may have little influence on high flexion kinematics (such as femoral rollback) with most of the load burden shared by supporting implant and soft-tissue structures.
Collapse
Affiliation(s)
- Markus Wünschel
- Department of Orthopaedic Surgery, University Hospital Tübingen, Hoppe-Seyler-Str. 3, 72076 Tübingen, Germany.
| | | | | | | | | | | |
Collapse
|
36
|
Wünschel M, Wülker N, Müller O. Gender differences in tibio-femoral kinematics and quadriceps muscle force during weight-bearing knee flexion in vitro. Knee Surg Sports Traumatol Arthrosc 2013; 21:2557-63. [PMID: 22696143 DOI: 10.1007/s00167-012-2082-7] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/23/2011] [Accepted: 05/29/2012] [Indexed: 11/26/2022]
Abstract
PURPOSE Females have a higher risk in terms of anterior cruciate ligament injuries during sports than males. Reasons for this fact may be different anatomy and muscle recruitment patterns leading to less protection for the cruciate- and collateral-ligaments. This in vitro study aims to evaluate gender differences in knee joint kinematics and muscle force during weight-bearing knee flexions. METHODS Thirty-four human knee specimens (17 females/17 males) were mounted on a dynamic knee simulator. Weight-bearing single-leg knee flexions were performed with different amounts of simulated body weight (BW). Gender-specific kinematics was measured with an ultrasonic motion capture system and different loading conditions were examined. RESULTS Knee joint kinematics did not show significant differences regarding anteroposterior and medial-lateral movement as well as tibial varus-valgus and internal-external rotation. This applied to all simulated amounts of BW. Simulating 100 N BW in contrast to AF50 led to a significant higher quadriceps overall force in female knees from 45° to 85° of flexion in contrast to BW 50 N. In these female specimens, the quadriceps overall force was about 20 % higher than in male knees being constant in higher flexion angles. CONCLUSIONS It is indicated by our results that in a squatting movement females compared with males produce higher muscle forces, suggesting an increased demand for muscular stabilization, whereas tibio-femoral kinematics was similar for both genders.
Collapse
Affiliation(s)
- Markus Wünschel
- Department of Orthopaedic Surgery, University Hospital Tübingen, Hoppe-Seyler-Str. 3, 72076, Tübingen, Germany,
| | | | | |
Collapse
|
37
|
Van Haver A, De Roo K, Claessens T, De Beule M, Verdonk P, De Baets P. Pilot validation study on a quasi-static weight-bearing knee rig. Proc Inst Mech Eng H 2013; 227:229-33. [PMID: 23662338 DOI: 10.1177/0954411912472595] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
This article presents a pilot study on a quasi-static knee rig designed to investigate the influence of pathologies and surgical interventions on the patellofemoral kinetics of cadaveric knees. The knee rig allows cadaveric knees to flex and extend under a simulated body weight by transmitting a force to the quadriceps tendon. During the squat simulation, the ground reaction force stays within physiological values. Before using this device to answer clinical questions, two knee specimens were tested to assess the repeatability of the rig. Four repeated flexion-extension cycles were performed under a simulated body weight of 700 N, with an isolated force on the quadriceps tendon up to 2700 N and with a ground reaction force close to 350 N. The resulting patellofemoral contact area shifted from distal to proximal during knee flexion. From 20 degrees to 60 degrees of knee flexion, the mean contact area and pressure increased from 80.2 +/- 3.3 to 349.5 +/- 10.1 mm2 and from 0.9 +/- 0.2 to 5.9 +/- 0.7 MPa, respectively. The transmitted force on the quadriceps tendon, the ground reaction force and the patellofemoral contact area and pressure were continuously measured and showed a relative variability of 1.6%, 2.4%, 2.8% and 3.2%, respectively. The presented knee rig shows a good repeatability that allows us to use this knee rig to quantify the influence of anatomical changes on the patellofemoral contact area and pressures during a squat simulation.
Collapse
Affiliation(s)
- Annemieke Van Haver
- Department of Mechanical Engineering, BioMech, University College Ghent, Ghent, Belgium.
| | | | | | | | | | | |
Collapse
|
38
|
Li K, Ackland DC, McClelland JA, Webster KE, Feller JA, de Steiger R, Pandy MG. Trunk muscle action compensates for reduced quadriceps force during walking after total knee arthroplasty. Gait Posture 2013. [PMID: 23206902 DOI: 10.1016/j.gaitpost.2012.10.018] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
Patients with total knee arthroplasty (TKA) frequently exhibit changes in gait biomechanics post-surgery, including decreased ranges of joint motion and changes in joint loading; however, the actions of the lower-limb muscles in generating joint moments and accelerating the center of mass (COM) during walking are yet to be described. The aim of the present study was to evaluate differences in lower-limb joint kinematics, muscle-generated joint moments, and muscle contributions to COM accelerations in TKA patients and healthy age-matched controls when both groups walk at the same speed. Each TKA patient was fitted with a posterior-stabilized total knee replacement and underwent patellar resurfacing. Three-dimensional gait analysis and subject-specific musculoskeletal modeling were used to determine lower-limb and trunk muscle forces and muscle contributions to COM accelerations during the stance phase of gait. The TKA patients exhibited a 'quadriceps avoidance' gait pattern, with the vasti contributing significantly less to the extension moment developed about the knee during early stance (p=0.036). There was a significant decrease in the contribution of the vasti to the vertical acceleration (support) (p=0.022) and forward deceleration of the COM (braking) (p=0.049) during early stance; however, the TKA patients compensated for this deficiency by leaning their trunks forward. This significantly increased the contribution of the contralateral back extensor muscle (erector spinae) to support (p=0.030), and that of the contralateral back rotators (internal and external obliques) to braking (p=0.004). These findings provide insight into the biomechanical causes of post-operative gait adaptations such as 'quadriceps avoidance' observed in TKA patients.
Collapse
Affiliation(s)
- Katherine Li
- Department of Mechanical Engineering, University of Melbourne, Parkville, Victoria 3010, Australia
| | | | | | | | | | | | | |
Collapse
|
39
|
Assessment of a medial pivot total knee arthroplasty design in a cadaveric knee extension test model. J Arthroplasty 2012; 27:1460-1468.e1. [PMID: 22906409 DOI: 10.1016/j.arth.2012.02.008] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/02/2010] [Accepted: 02/07/2012] [Indexed: 02/01/2023] Open
Abstract
A total knee has been designed to mimic less-compliant medial and more-compliant lateral behavior. In vivo testing compared open-kinematic chain behaviors of cadaver knees in their normal state and after implantation of the knee prosthesis. Specimen's limbs were computed tomography scanned, and infrared arrays on tibia and femur were registered to bone markers. Motion of the joint and quadriceps force were reported from 90° flexion to full extension. Less medial and more lateral anterior-posterior motion was seen in both the intact and the implanted knees. Tibiofemoral rotation and translation were similar in direction but were reduced in magnitude for the prosthetic knees. Quadriceps force, defined as that applied force required to extend the knee, required after implantation was variable between specimens but not statistically different from the intact condition. The prosthesis tested exhibits kinematic behavior similar to that in their normal state, with no difference in quadriceps force required for extension.
Collapse
|
40
|
Fitzpatrick CK, Baldwin MA, Clary CW, Maletsky LP, Rullkoetter PJ. Evaluating knee replacement mechanics during ADL with PID-controlled dynamic finite element analysis. Comput Methods Biomech Biomed Engin 2012; 17:360-9. [PMID: 22687046 DOI: 10.1080/10255842.2012.684242] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
Abstract
Validated computational knee simulations are valuable tools for design phase development of knee replacement devices. Recently, a dynamic finite element (FE) model of the Kansas knee simulator was kinematically validated during gait and deep flexion cycles. In order to operate the computational simulator in the same manner as the experiment, a proportional-integral-derivative (PID) controller was interfaced with the FE model to control the quadriceps actuator excursion and produce a target flexion profile regardless of implant geometry or alignment conditions. The controller was also expanded to operate multiple actuators simultaneously in order to produce in vivo loading conditions at the joint during dynamic activities. Subsequently, the fidelity of the computational model was improved through additional muscle representation and inclusion of relative hip-ankle anterior-posterior (A-P) motion. The PID-controlled model was able to successfully recreate in vivo loading conditions (flexion angle, compressive joint load, medial-lateral load distribution or varus-valgus torque, internal-external torque, A-P force) for deep knee bend, chair rise, stance-phase gait and step-down activities.
Collapse
Affiliation(s)
- Clare K Fitzpatrick
- a Computational Biomechanics Lab , University of Denver , 2390 S. York Street, Denver , CO 80208 , USA
| | | | | | | | | |
Collapse
|
41
|
Catani F, Belvedere C, Ensini A, Feliciangeli A, Giannini S, Leardini A. In-vivo knee kinematics in rotationally unconstrained total knee arthroplasty. J Orthop Res 2011; 29:1484-90. [PMID: 21452303 DOI: 10.1002/jor.21397] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/19/2010] [Accepted: 02/07/2011] [Indexed: 02/04/2023]
Abstract
Total knee replacement designs claim characteristic kinematic performance that is rarely assessed in patients. In the present study, in vivo kinematics of a new prosthesis design was measured during activities of daily living. This design is posterior stabilized for which spine-cam interaction coordinates free axial rotation throughout the flexion-extension arc by means of a single radius of curvature for the femoral condyles in the sagittal and frontal planes. Fifteen knees were implanted with this prosthesis, and 3D video-fluoroscopic analysis was performed at 6-month follow-up for three motor tasks. The average range of flexion was 70.1° (range: 60.1-80.2°) during stair-climbing, 74.7° (64.6-84.8°) during chair-rising, and 64.1° (52.9-74.3°) during step-up. The corresponding average rotation on the tibial base-plate of the lines between the medial and lateral contact points was 9.4° (4.0-22.4°), 11.4° (4.6-22.7°), and 11.3° (5.1-18.0°), respectively. The pivot point for these lines was found mostly in the central area of the base-plate. Nearly physiological range of axial rotation can be achieved at the replaced knee during activities of daily living.
Collapse
Affiliation(s)
- Fabio Catani
- Department of Orthopedic Surgery, Istituto Ortopedico Rizzoli, Bologna, Italy
| | | | | | | | | | | |
Collapse
|
42
|
Zhu Z, Ding H, Dang X, Tang J, Zhou Y, Wang G. In vitro kinematic measurements of the patellar tendon in two different types of posterior-stabilized total knee arthroplasties. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2011; 2010:3938-41. [PMID: 21097088 DOI: 10.1109/iembs.2010.5627702] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
BACKGROUND Fixed-bearing posterior-stabilized (PS) total knee arthroplasty (TKA) has been used in Asian countries for several years, but few studies have investigated differences in the kinematic properties of the patellar tendon after standard PS TKA as compared to high-flex PS TKA. PURPOSE To quantify the in vitro three-dimensional (3D) kinematics of the patellar tendon during passive high flexion and full extension before and after two different types of PS TKAs. METHODS Six fresh-frozen cadaveric knees were tested under the following conditions: the unaltered state, status-post traditional PS prostheses (Simth-nephew GENESIS II) replacement, and status-post high-flexion PS prostheses replacement. The soft tissue around the knee and the quadriceps muscle were preserved, then tested under the load of a specific weight in an Oxford knee rig. We designed a specialized rigid body with four active markers fixed to each bone to track the 3D passive motion of the cadaveric knees. Flexion and extension was controlled by the knee rig and captured by an Optotrak Certus high precision optical tracking system. The attachment sites of the patellar tendon were registered as virtual markers to calculate the 3D kinematics. RESULTS The patellar tendon of the unaltered knee and both TKA knees showed similar deformation. We found the length of the patellar tendon changed significantly during a motion from full extension to 30°, but there was no significant change in length while undergoing a motion from 30° to full flexion. Both the sagittal plane and coronal plane angles of the patellar tendon decreased after PS TKAs. There was no significant difference in patellar tendon kinematics between the two types of PS TKAs. CONCLUSION We believe the changes observed in the sagittal plane and coronal plane angles of the patellar tendon after PS TKAs may influence the extensor mechanism and be an important cause of patella-femoral complications. These data may be used to assess patella-femoral complications after surgery so as to improve the design of high-flexion TKAs for Asians and achieve long-term stability.
Collapse
Affiliation(s)
- Zhonglin Zhu
- Department of Biomedical Engineering, Tsinghua University, 100084, China
| | | | | | | | | | | |
Collapse
|
43
|
Varadarajan KM, Freiberg AA, Gill TJ, Rubash HE, Li G. Relationship between three-dimensional geometry of the trochlear groove and in vivo patellar tracking during weight-bearing knee flexion. J Biomech Eng 2011; 132:061008. [PMID: 20887033 DOI: 10.1115/1.4001360] [Citation(s) in RCA: 40] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
It is widely recognized that the tracking of patella is strongly influenced by the geometry of the trochlear groove. Nonetheless, quantitative baseline data regarding correlation between the three-dimensional geometry of the trochlear groove and patellar tracking under in vivo weight-bearing conditions are not available. A combined magnetic resonance and dual fluoroscopic imaging technique, coupled with multivariate regression analysis, was used to quantify the relationship between trochlear groove geometry (sulcus location, bisector angle, and coronal plane angle) and in vivo patellar tracking (shift, tilt, and rotation) during weight-bearing knee flexion. The results showed that in the transverse plane, patellar shift was strongly correlated (correlation coefficient R=0.86, p<0.001) to mediolateral location of the trochlear sulcus (raw regression coefficient β(raw)=0.62) and the trochlear bisector angle (β(raw)=0.31). Similarly, patellar tilt showed a significant association with the trochlear bisector angle (R=0.45, p<0.001, and β(raw)=0.60). However, in the coronal plane patellar rotation was poorly correlated with its matching geometric parameter, namely, the coronal plane angle of the trochlea (R=0.26, p=0.01, β(raw)=0.08). The geometry of the trochlear groove in the transverse plane of the femur had significant effect on the transverse plane motion of the patella (patellar shift and tilt) under in vivo weight-bearing conditions. However, patellar rotation in the coronal plane was weakly correlated with the trochlear geometry.
Collapse
Affiliation(s)
- Kartik M Varadarajan
- Bioengineering Laboratory, Orthopaedic Surgery, MGH/Harvard Medical School, Boston, MA 02114, USA
| | | | | | | | | |
Collapse
|
44
|
Wünschel M, Lo J, Dilger T, Wülker N, Müller O. Influence of bi- and tri-compartmental knee arthroplasty on the kinematics of the knee joint. BMC Musculoskelet Disord 2011; 12:29. [PMID: 21272328 PMCID: PMC3224381 DOI: 10.1186/1471-2474-12-29] [Citation(s) in RCA: 44] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/06/2010] [Accepted: 01/27/2011] [Indexed: 12/05/2022] Open
Abstract
Background The cruciate ligaments are important stabilizers of the knee joint and determine joint kinematics in the natural knee and after cruciate retaining arthroplasty. No in vitro data is available to biomechanically evaluate the ability of the anterior cruciate ligament (ACL) to maintain knee joint kinematics after bicruciate-retaining bi-compartmental knee arthroplasty (BKA). Therefore, the objective of the current study was to investigate the kinematics of the natural knee joint, before and after installing bicruciate-retaining BKA and posterior cruciate retaining total knee arthroplasty. Specifically, we incorporated a dynamic knee simulator to simulate weight-bearing flexions on cadaveric knee specimen before and after surgical manipulations. Methods In this cadaveric study we investigated rotational and translational tibiofemoral kinematics during simulated weight-bearing flexions of the intact knee, after bi-compartmental knee arthroplasty (BKA+), after resecting the ACL in BKA (BKA-), and after posterior cruciate retaining total knee arthroplasty (TKA). Results Rotation of BKA+ is closest to the intact knee joint, whereas TKA shows significant differences from 30 to 90 degree of flexion. Within the tested flexion range (15 to 90 degree of flexion), there was no significant difference in the anterior-posterior translation among intact, BKA+, and TKA knees. Resecting the ACL in BKA leads to a significant anterior tibial translation. Conclusions BKA with intact cruciate ligaments resembles rotation and translation of the natural knee during a simulated weight-bearing flexion. It is a suitable treatment option for medial and patellofemoral osteoarthritis with advantages in rotational characteristics compared to TKA.
Collapse
Affiliation(s)
- Markus Wünschel
- Department of Orthopaedic Surgery, University Hospital Tübingen, Hoppe-Seyler-Str, 3, 72076 Tübingen, Germany.
| | | | | | | | | |
Collapse
|
45
|
Yue B, Varadarajan KM, Moynihan AL, Liu F, Rubash HE, Li G. Kinematics of medial osteoarthritic knees before and after posterior cruciate ligament retaining total knee arthroplasty. J Orthop Res 2011; 29:40-6. [PMID: 20607694 DOI: 10.1002/jor.21203] [Citation(s) in RCA: 64] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
Total knee arthroplasty (TKA) is a widely accepted surgical procedure for the treatment of patients with end-stage osteoarthritis (OA). However, the function of the knee is not always fully recovered after TKA. We used a dual fluoroscopic imaging system to evaluate the in vivo kinematics of the knee with medial compartment OA before and after a posterior cruciate ligament-retaining TKA (PCR-TKA) during weight-bearing knee flexion, and compared the results to those of normal knees. The OA knees displayed similar internal/external tibial rotation to normal knees. However, the OA knees had less overall posterior femoral translation relative to the tibia between 0° and 105° flexion and more varus knee rotation between 0° and 45° flexion, than in the normal knees. Additionally, in the OA knees the femur was located more medially than in the normal knees, particularly between 30° and 60° flexion. After PCR-TKA, the knee kinematics were not restored to normal. The overall internal tibial rotation and posterior femoral translation between 0° and 105° knee flexion were dramatically reduced. Additionally, PCR-TKA introduced an abnormal anterior femoral translation during early knee flexion, and the femur was located lateral to the tibia throughout weight-bearing flexion. The data help understand the biomechanical functions of the knee with medial compartment OA before and after contemporary PCR-TKA. They may also be useful for improvement of future prostheses designs and surgical techniques in treatment of knees with end-stage OA.
Collapse
Affiliation(s)
- Bing Yue
- Bioengineering Laboratory, Department of Orthopaedic Surgery, Massachusetts General Hospital and Harvard Medical School, 55 Fruit St, GRJ 1215, Boston, Massachusetts 02114, USA
| | | | | | | | | | | |
Collapse
|