1
|
Wu J, He XT, Sun JY. A Theoretical Study on Static Gas Pressure Measurement via Circular Non-Touch Mode Capacitive Pressure Sensor. SENSORS (BASEL, SWITZERLAND) 2024; 24:5314. [PMID: 39205008 PMCID: PMC11359305 DOI: 10.3390/s24165314] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/05/2024] [Revised: 08/02/2024] [Accepted: 08/14/2024] [Indexed: 09/04/2024]
Abstract
A circular non-touch mode capacitive pressure sensor can operate in both transverse and normal uniform loading modes, but the elastic behavior of its movable electrode plate is different under the two different loading modes, making its input-output analytical relationships between pressure and capacitance different. This suggests that when such a sensor operates, respectively, in transverse and normal uniform loading modes, the theory of its numerical design and calibration is different, in other words, the theory for the transverse uniform loading mode (available in the literature) cannot be used as the theory for the normal uniform loading mode (not yet available in the literature). In this paper, a circular non-touch mode capacitive pressure sensor operating in normal uniform loading mode is considered. The elastic behavior of the movable electrode plate of the sensor under normal uniform loading is analytically solved with the improved governing equations, and the improved analytical solution obtained can be used to mathematically describe the movable electrode plate with larger elastic deflections, in comparison with the existing two analytical solutions in the literature. This provides a larger technical space for developing the circular non-touch mode capacitive pressure sensors used for measuring the static gas pressure (belonging to normal uniform loading).
Collapse
Affiliation(s)
- Ji Wu
- School of Civil Engineering, Chongqing University, Chongqing 400045, China
| | - Xiao-Ting He
- School of Civil Engineering, Chongqing University, Chongqing 400045, China
- Key Laboratory of New Technology for Construction of Cities in Mountain Area (Chongqing University), Ministry of Education, Chongqing 400045, China
| | - Jun-Yi Sun
- School of Civil Engineering, Chongqing University, Chongqing 400045, China
- Key Laboratory of New Technology for Construction of Cities in Mountain Area (Chongqing University), Ministry of Education, Chongqing 400045, China
| |
Collapse
|
2
|
Maiwald V, Bauerfeind M, Fälker S, Westphal B, Bach C. About feasibility of SpaceX's human exploration Mars mission scenario with Starship. Sci Rep 2024; 14:11804. [PMID: 38782962 PMCID: PMC11116405 DOI: 10.1038/s41598-024-54012-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2023] [Accepted: 02/06/2024] [Indexed: 05/25/2024] Open
Abstract
After decades where human spaceflight missions have been reserved to low Earth orbit, recent years have seen mission proposals and even implemented plans, e.g. with the mission Artemis I, for returning to the lunar surface. SpaceX has published over various media (e.g., its official website, conference presentations, user manual) conceptual information for its reusable Starship to enable human exploration missions to the Martian surface by the end of the decade. The technological and human challenges associated with these plans are daunting. Such a mission at that distance would require excellent system reliability and in-situ-resource utilization on a grand scale, e.g. to produce propellant. The plans contain little details however and have not yet been reviewed concerning their feasibility. In this paper we show significant technological gaps in these plans. Based on estimates and extrapolated data, a mass model as needed to fulfill SpaceX's plans could not be reproduced and the subsequent trajectory optimization showed that the current plans do not yield a return flight opportunity, due to a too large system mass. Furthermore, significant gaps exist in relevant technologies, e.g. power supply for the Martian surface. It is unlikely that these gaps can be closed until the end of the decade. We recommend several remedies, e.g. stronger international participation to distribute technology development and thus improve feasibility. Overall, with the limited information published by SpaceX about its system and mission scenario and extrapolation from us to fill information gaps, we were not able to find a feasible Mars mission scenario using Starship, even when assuming optimal conditions such as 100% recovery rate of crew consumables during flight.
Collapse
Affiliation(s)
- Volker Maiwald
- German Aerospace Center (DLR), Institute of Space Systems, Bremen, Germany.
| | - Mika Bauerfeind
- Faculty of Production Engineering, University of Bremen, Bremen, Germany
| | - Svenja Fälker
- Chair of Space Systems, Technical University Dresden, Dresden, Germany
| | | | - Christian Bach
- Chair of Space Systems, Technical University Dresden, Dresden, Germany
| |
Collapse
|
3
|
Ma B, Bai Y, Hu C, Xie B, Zhang J, Ulbricht M, Zheng L. Space aquatic chemistry: A roadmap for drinking water treatment in microgravity. ENVIRONMENTAL SCIENCE AND ECOTECHNOLOGY 2024; 19:100344. [PMID: 38192688 PMCID: PMC10772392 DOI: 10.1016/j.ese.2023.100344] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/03/2023] [Accepted: 11/08/2023] [Indexed: 01/10/2024]
Abstract
Rapid advancement in aerospace technology has successfully enabled long-term life and economic activities in space, particularly in Low Earth Orbit (LEO), extending up to 2000 km from the mean sea level. However, the sustainance of the LEO Economy and its Environmental Control and Life Support System (ECLSS) still relies on a regular cargo supply of essential commodities (e.g., water, food) from Earth, for which there still is a lack of adequate and sustainable technologies. One key challenge in this context is developing water treatment technologies and standards that can perform effectively under microgravity conditions. Solving this technical challenge will be a milestone in providing a scientific basis and the necessary support mechanisms for establishing permanent bases in outer space and beyond. To identify clues towards solving this challenge, we looked back at relevant scientific research exploring novel technologies and standards for deep space exploration, also considering feedback for enhancing these technologies on land. Synthesizing our findings, we share our outlook for the future of drinking water treatment in microgravity. We also bring up a new concept for space aquatic chemistry, considering the closed environment of engineered systems operating in microgravity.
Collapse
Affiliation(s)
- Baiwen Ma
- Key Laboratory of Drinking Water Science and Technology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing, 100085, China
- Lehrstuhl für Technische Chemie II, Universität Duisburg-Essen, Essen, 45117, Germany
| | - Yaohui Bai
- Key Laboratory of Drinking Water Science and Technology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing, 100085, China
| | - Chengzhi Hu
- Key Laboratory of Drinking Water Science and Technology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing, 100085, China
| | - Beizhen Xie
- Institute of Environmental Biology and Life Support Technology, School of Biological Science and Medical Engineering, Beihang University, Beijing, 100191, China
| | - Junya Zhang
- Department of Water Pollution Control, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing, 100085, China
- Department of Isotope Biogeochemistry, Helmholtz Centre for Environmental Research - UFZ, Leipzig, 04318, Germany
| | - Mathias Ulbricht
- Lehrstuhl für Technische Chemie II, Universität Duisburg-Essen, Essen, 45117, Germany
| | - Libing Zheng
- Lehrstuhl für Technische Chemie II, Universität Duisburg-Essen, Essen, 45117, Germany
- Department of Water Pollution Control, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing, 100085, China
| |
Collapse
|
4
|
He XT, Wang X, Li FY, Sun JY. An Improved Theory for Designing and Numerically Calibrating Circular Touch Mode Capacitive Pressure Sensors. SENSORS (BASEL, SWITZERLAND) 2024; 24:907. [PMID: 38339625 PMCID: PMC11154444 DOI: 10.3390/s24030907] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/13/2023] [Revised: 01/22/2024] [Accepted: 01/29/2024] [Indexed: 02/12/2024]
Abstract
The design, especially the numerical calibration, of a circular touch mode capacitive pressure sensor is highly dependent on the accuracy of the analytical solution of the contact problem between the circular conductive membrane and the rigid plate of the sensor. In this paper, the plate/membrane contact problem is reformulated using a more accurate in-plane equilibrium equation, and a new and more accurate analytical solution is presented. On this basis, the design and numerical calibration theory for circular touch mode capacitive pressure sensors has been greatly improved and perfected. The analytical relationships of pressure and capacitance are numerically calculated using the new and previous analytical solutions, and the gradually increasing difference between the two numerical calculation results with the gradual increase in the applied pressure is graphically shown. How to use analytical solutions and analytical relationships to design and numerically calibrate a circular touch mode capacitive pressure sensor with a specified pressure detecting range is illustrated in detail. The effect of changing design parameters on capacitance-pressure analytical relationships is comprehensively investigated; thus, the direction of changing design parameters to meet the required or desired range of pressure or capacitance is clarified.
Collapse
Affiliation(s)
- Xiao-Ting He
- School of Civil Engineering, Chongqing University, Chongqing 400045, China; (X.W.); (F.-Y.L.); (J.-Y.S.)
- Key Laboratory of New Technology for Construction of Cities in Mountain Area (Chongqing University), Ministry of Education, Chongqing 400045, China
| | - Xin Wang
- School of Civil Engineering, Chongqing University, Chongqing 400045, China; (X.W.); (F.-Y.L.); (J.-Y.S.)
| | - Fei-Yan Li
- School of Civil Engineering, Chongqing University, Chongqing 400045, China; (X.W.); (F.-Y.L.); (J.-Y.S.)
| | - Jun-Yi Sun
- School of Civil Engineering, Chongqing University, Chongqing 400045, China; (X.W.); (F.-Y.L.); (J.-Y.S.)
- Key Laboratory of New Technology for Construction of Cities in Mountain Area (Chongqing University), Ministry of Education, Chongqing 400045, China
| |
Collapse
|
5
|
Suresh R, Rajendran S, Gnanasekaran L, Show PL, Chen WH, Soto-Moscoso M. Modified poly(vinylidene fluoride) nanomembranes for dye removal from water - A review. CHEMOSPHERE 2023; 322:138152. [PMID: 36791812 DOI: 10.1016/j.chemosphere.2023.138152] [Citation(s) in RCA: 9] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/29/2022] [Revised: 01/26/2023] [Accepted: 02/12/2023] [Indexed: 06/18/2023]
Abstract
Water contamination due to soluble synthetic dyes has serious concerns. Membrane-based wastewater treatments are emerging as a preferred choice for removing dyes from water. Poly(vinylidene fluoride) (PVDF)-based nanomembranes have gained much popularity due to their favorable features. This review explores the application of PVDF-based nanomembranes in synthetic dye removal through various treatments. Different fabrication methods to obtain high performance PVDF-based nanomembranes were discussed under surface coating and blending methods. Studies related to use of PVDF-based nanomembranes in adsorption, filtration, catalysis (oxidant activation, ozonation, Fenton process and photocatalysis) and membrane distillation have been elaborately discussed. Nanomaterials including metal compounds, metals, (synthetic/bio)polymers, metal organic frameworks, carbon materials and their composites were incorporated in PVDF membrane to enhance its performance. The advantages and limitations of incorporating nanomaterials in PVDF-based membranes have been highlighted. The influence of nanomaterials on the surface features, mechanical strength, hydrophilicity, crystallinity and catalytic ability of PVDF membrane was discussed. The conclusion of this literature review was given along with future research.
Collapse
Affiliation(s)
- R Suresh
- Departamento de Ingeniería Mecánica, Facultad de Ingeniería, Universidad de Tarapacá, Avda. General Velásquez, 1775, Arica, Chile.
| | - Saravanan Rajendran
- Departamento de Ingeniería Mecánica, Facultad de Ingeniería, Universidad de Tarapacá, Avda. General Velásquez, 1775, Arica, Chile; Department of Chemical Engineering, Lebanese American University, Byblos, Lebanon; Saveetha School of Engineering, Saveetha Institute of Medical and Technical Science, Chennai, 602105, India
| | - Lalitha Gnanasekaran
- Departamento de Ingeniería Mecánica, Facultad de Ingeniería, Universidad de Tarapacá, Avda. General Velásquez, 1775, Arica, Chile; University Centre for Research & Development, Department of Mechanical Engineering, Chandigarh University, Mohali, Punjab, 140413, India.
| | - Pau Loke Show
- Zhejiang Provincial Key Laboratory for Subtropical Water Environment and Marine Biological Resources Protection, Wenzhou University, Wenzhou, 325035, China; Department of Chemical and Environmental Engineering, University of Nottingham Malaysia, Jalan Broga, 43500, Semenyih, Selangor Darul Ehsan, Malaysia
| | - Wei-Hsin Chen
- Department of Aeronautics and Astronautics, National Cheng Kung University, Tainan, 701, Taiwan; Research Center for Smart Sustainable Circular Economy, Tunghai University, Taichung, 407, Taiwan; Department of Mechanical Engineering, National Chin-Yi University of Technology, Taichung, 411, Taiwan
| | | |
Collapse
|
6
|
Jurga A, Ratkiewicz K, Wdowikowska A, Reda M, Janicka M, Chohura P, Janiak K. Urine and grey water based liquid fertilizer - Production and the response of plants. JOURNAL OF ENVIRONMENTAL MANAGEMENT 2023; 331:117248. [PMID: 36652879 DOI: 10.1016/j.jenvman.2023.117248] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/12/2022] [Revised: 12/21/2022] [Accepted: 01/04/2023] [Indexed: 06/17/2023]
Abstract
Plant cultivation is a key aspect of future long-distance space missions, and the creation of an efficient food system will not be possible without it. The production of fertilizer in space is based on the recovery of water and nutrients from wastewater, such as urine and grey water. In this study, the fertilizer production process was conducted in an aerobic, activated sludge reactor, where nitrification and the process of carbon removal take place. Treated streams have three potential factors that could affect the plants growth in a hydroponic system (anionic surfactants, nutrients deficiencies, high salinity). The effect of these factors was examined for two hydroponic configurations. Their influence on lettuce yield, quality parameters and stress response were investigated and compared to the control cultivation. The results showed that the main cause of a decrease (up to 24%) in the yield productivity of plants grown on nitrified urine and grey water is oxidative stress originated from a deficiency of elements, not from used anionic surfactant. Enrichment with nutrients resulted in the restoration of proper protein synthesis and an increase in the activity of antioxidant enzymes, which was positively reflected in the qualitative and quantitative parameters of the enriched cultivation (fresh leaves mass equal to 103% of the control). Results also show that Sodium Methyl Cocoyl Taurate (SMCT) surfactant itself after biological treatment used in plant cultivation has no negative effects reflected in lettuce yield or quality.
Collapse
Affiliation(s)
- Anna Jurga
- Faculty of Environmental Engineering, Wroclaw University of Science and Technology, Wybrzeże Wyspiańskiego 27, 50-370, Wroclaw, Poland.
| | - Krzysztof Ratkiewicz
- Faculty of Environmental Engineering, Wroclaw University of Science and Technology, Wybrzeże Wyspiańskiego 27, 50-370, Wroclaw, Poland
| | - Anna Wdowikowska
- Department of Plant Molecular Physiology, Faculty of Biological Science, University of Wrocław, Kanonia 6/8, 50-328, Wroclaw, Poland
| | - Małgorzata Reda
- Department of Plant Molecular Physiology, Faculty of Biological Science, University of Wrocław, Kanonia 6/8, 50-328, Wroclaw, Poland
| | - Małgorzata Janicka
- Department of Plant Molecular Physiology, Faculty of Biological Science, University of Wrocław, Kanonia 6/8, 50-328, Wroclaw, Poland
| | - Piotr Chohura
- Faculty of Life Science and Technology, Wroclaw University of Environmental and Life Sciences, St. C. K. Norwida 27, 50-375, Wroclaw, Poland
| | - Kamil Janiak
- Faculty of Environmental Engineering, Wroclaw University of Science and Technology, Wybrzeże Wyspiańskiego 27, 50-370, Wroclaw, Poland; Wroclaw Municipal Water and Sewage Company, Na Grobli 19, 50-421, Wroclaw, Poland
| |
Collapse
|
7
|
Pașcu D, Nechifor AC, Grosu VA, Oprea OC, Tanczos SK, Man GT, Dumitru F, Grosu AR, Nechifor G. Hydrogen Sulphide Sequestration with Metallic Ions in Acidic Media Based on Chitosan/sEPDM/Polypropylene Composites Hollow Fiber Membranes System. MEMBRANES 2023; 13:350. [PMID: 36984736 PMCID: PMC10057485 DOI: 10.3390/membranes13030350] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/31/2023] [Revised: 03/10/2023] [Accepted: 03/14/2023] [Indexed: 06/18/2023]
Abstract
This paper presents the preparation and characterization of composite membranes based on chitosan (Chi), sulfonated ethylene-propylene-diene terpolymer (sEPDM), and polypropylene (PPy), and designed to capture hydrogen sulfide. The Chi/sEPDM/PPy composite membranes were prepared through controlled evaporation of a toluene dispersion layer of Chi:sEPDM 1;1, w/w, deposited by immersion and under a slight vacuum (100 mmHg) on a PPy hollow fiber support. The composite membranes were characterized morphologically, structurally, and thermally, but also from the point of view of their performance in the process of hydrogen sulfide sequestration in an acidic media solution with metallic ion content (Cu2+, Cd2+, Pb2+, and/or Zn2+). The operational parameters of the pertraction were the pH, pM, matrix gas flow rate, and composition. The results of pertraction from synthetic gases mixture (nitrogen, methane, carbon dioxide) indicated an efficient removal of hydrogen sulfide through the prepared composite membranes, as well as its immobilization as sulfides. The sequestration and the recuperative separation, as sulfides from an acid medium, of the hydrogen sulfide reached up to 96%, decreasing in the order: CuS > PbS > CdS > ZnS.
Collapse
Affiliation(s)
- Dumitru Pașcu
- Analytical Chemistry and Environmental Engineering Department, University Politehnica of Bucharest, 011061 Bucharest, Romania
| | - Aurelia Cristina Nechifor
- Analytical Chemistry and Environmental Engineering Department, University Politehnica of Bucharest, 011061 Bucharest, Romania
| | - Vlad-Alexandru Grosu
- Department of Electronic Technology and Reliability, Faculty of Electronics, Telecommunications and Information Technology, University Politehnica of Bucharest, 061071 Bucharest, Romania
| | - Ovidiu Cristian Oprea
- Department of Inorganic Chemistry, Physical Chemistry and Electrochemistry, University Politehnica of Bucharest, 011061 Bucharest, Romania
| | - Szidonia-Katalin Tanczos
- Department of Bioengineering, University Sapientia of Miercurea-Ciuc, 500104 Miercurea-Ciuc, Romania
| | - Geani Teodor Man
- Analytical Chemistry and Environmental Engineering Department, University Politehnica of Bucharest, 011061 Bucharest, Romania
| | - Florina Dumitru
- Department of Inorganic Chemistry, Physical Chemistry and Electrochemistry, University Politehnica of Bucharest, 011061 Bucharest, Romania
| | - Alexandra Raluca Grosu
- Analytical Chemistry and Environmental Engineering Department, University Politehnica of Bucharest, 011061 Bucharest, Romania
| | - Gheorghe Nechifor
- Analytical Chemistry and Environmental Engineering Department, University Politehnica of Bucharest, 011061 Bucharest, Romania
| |
Collapse
|
8
|
Zhang Q, Li FY, Li X, He XT, Sun JY. Polymer Conductive Membrane-Based Circular Capacitive Pressure Sensors from Non-Touch Mode of Operation to Touch Mode of Operation: An Analytical Solution-Based Method for Design and Numerical Calibration. Polymers (Basel) 2022; 14:polym14183850. [PMID: 36145995 PMCID: PMC9501485 DOI: 10.3390/polym14183850] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2022] [Revised: 09/08/2022] [Accepted: 09/09/2022] [Indexed: 11/19/2022] Open
Abstract
Polymer-based conductive membranes play an important role in the development of elastic deflection-based pressure sensors. In this paper, an analytical solution-based method is presented for the design and numerical calibration of polymer conductive membrane-based circular capacitive pressure sensors from non-touch mode of operation to touch mode of operation. The contact problem of a circular membrane in frictionless contact with a rigid flat plate under pressure is analytically solved, and its analytical solution is used for the design of touch mode circular capacitive pressure sensors for the first time. The analytical relationship with input pressure as independent variable and output capacitance as dependent variable is precisely derived and is used for the numerical calibrations of the analytical relationships with input capacitance as the independent variable and output pressure as the dependent variable in order to meet the capacitive pressure sensor mechanism of detecting pressure by measuring capacitance. For the first time, an example showing the design and numerical calibration of a given (given design parameters) polymer conductive membrane-based circular capacitive pressure sensor from non-touch mode of operation to touch mode of operation is provided. Then, the influence of changing several important design parameters on input capacitance–output pressure relationships is comprehensively investigated in order to clarify the desired input–output relationships when changing design parameters.
Collapse
Affiliation(s)
- Qi Zhang
- School of Civil Engineering, Chongqing University, Chongqing 400045, China
| | - Fei-Yan Li
- School of Civil Engineering, Chongqing University, Chongqing 400045, China
| | - Xue Li
- School of Civil Engineering, Chongqing University, Chongqing 400045, China
| | - Xiao-Ting He
- School of Civil Engineering, Chongqing University, Chongqing 400045, China
- Key Laboratory of New Technology for Construction of Cities in Mountain Area (Chongqing University), Ministry of Education, Chongqing 400045, China
| | - Jun-Yi Sun
- School of Civil Engineering, Chongqing University, Chongqing 400045, China
- Key Laboratory of New Technology for Construction of Cities in Mountain Area (Chongqing University), Ministry of Education, Chongqing 400045, China
- Correspondence: ; Tel.: +86-(0)23-65120720
| |
Collapse
|
9
|
Li FY, Zhang Q, Li X, He XT, Sun JY. Polymer Conductive Membrane-Based Non-Touch Mode Circular Capacitive Pressure Sensors: An Analytical Solution-Based Method for Design and Numerical Calibration. Polymers (Basel) 2022; 14:polym14153087. [PMID: 35956600 PMCID: PMC9370657 DOI: 10.3390/polym14153087] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2022] [Revised: 07/24/2022] [Accepted: 07/26/2022] [Indexed: 11/16/2022] Open
Abstract
In this paper, an analytical solution-based method for the design and numerical calibration of polymer conductive membrane-based non-touch mode circular capacitive pressure sensors is presented. The accurate analytical relationship between the capacitance and applied pressure of the sensors is derived by using the analytical solution for the elastic behavior of the circular polymer conductive membranes under pressure. Based on numerical calculations using the accurate analytical relationship and the analytical solution, the analytical relationship between the pressure as output and the capacitance as input, which is necessary to achieve the capacitive pressure sensor mechanism of detecting pressure by measuring capacitance, is accurately established by least-squares data fitting. An example of how to arrive at the design and numerical calibration of a non-touch mode circular capacitive pressure sensor is first given. Then, the influence of changing design parameters such as membrane thickness and Young’s modulus of elasticity on input–output relationships is investigated, thus clarifying the direction of approaching the desired input–output relationships by changing design parameters.
Collapse
Affiliation(s)
- Fei-Yan Li
- School of Civil Engineering, Chongqing University, Chongqing 400045, China; (F.-Y.L.); (Q.Z.); (X.L.); (X.-T.H.)
| | - Qi Zhang
- School of Civil Engineering, Chongqing University, Chongqing 400045, China; (F.-Y.L.); (Q.Z.); (X.L.); (X.-T.H.)
| | - Xue Li
- School of Civil Engineering, Chongqing University, Chongqing 400045, China; (F.-Y.L.); (Q.Z.); (X.L.); (X.-T.H.)
| | - Xiao-Ting He
- School of Civil Engineering, Chongqing University, Chongqing 400045, China; (F.-Y.L.); (Q.Z.); (X.L.); (X.-T.H.)
- Key Laboratory of New Technology for Construction of Cities in Mountain Area (Chongqing University), Ministry of Education, Chongqing 400045, China
| | - Jun-Yi Sun
- School of Civil Engineering, Chongqing University, Chongqing 400045, China; (F.-Y.L.); (Q.Z.); (X.L.); (X.-T.H.)
- Key Laboratory of New Technology for Construction of Cities in Mountain Area (Chongqing University), Ministry of Education, Chongqing 400045, China
- Correspondence: ; Tel.: +86-(0)23-65120720
| |
Collapse
|
10
|
A Further Theoretical Study of Capacitive Pressure Sensors Based on Thin Film Elastic Deflection and Parallel Plate Capacitor: Refined Closed-Form Solution and Numerical Calibration. SENSORS 2022; 22:s22082848. [PMID: 35458832 PMCID: PMC9029114 DOI: 10.3390/s22082848] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/10/2022] [Revised: 03/31/2022] [Accepted: 04/05/2022] [Indexed: 11/17/2022]
Abstract
The capacitive pressure sensor based on thin film elastic deflection and a parallel plate capacitor uses a non-conductive elastic annular thin film centrally connected to a conductive, rigid, flat, concentric-circular thin plate as a pressure sensing unit. On application of pressure, the non-conductive thin film deflects elastically, which in turn moves the conductive thin plate (as a movable upper electrode plate of the parallel plate capacitor) towards the lower electrode plate, resulting in a change in the capacitance of the capacitor. Therefore, the applied pressure can be determined by measuring the capacitance change, based on the closed-form solution for the elastic behavior of the annular thin film under pressure. Such capacitive pressure sensors are more suitable for large-sized sensors such as those used for building-facade wind pressure measurements, etc. In this paper, a further theoretical study of such capacitive pressure sensors is presented. The newly presented, more refined closed-form solution can greatly reduce the output pressure error under the same input capacitance, in comparison with the previously presented closed-form solution. A numerical example of how to use the resulting closed-form solution to numerically calibrate input-output characteristics is given for the first time. The variation trend of pressure operation ranges and input-output characteristics with important parametric variations, which can be used for guiding the design of such capacitive pressure sensors, is investigated.
Collapse
|
11
|
NaCl precleaning of microfiltration membranes fouled with oil-in-water emulsions: Impact on fouling dislodgment. Sep Purif Technol 2022. [DOI: 10.1016/j.seppur.2021.120353] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/21/2023]
|
12
|
Green H 2 Production by Water Electrolysis Using Cation Exchange Membrane: Insights on Activation and Ohmic Polarization Phenomena. MEMBRANES 2021; 12:membranes12010015. [PMID: 35054542 PMCID: PMC8778150 DOI: 10.3390/membranes12010015] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/02/2021] [Revised: 12/09/2021] [Accepted: 12/21/2021] [Indexed: 11/20/2022]
Abstract
Low-temperature electrolysis by using polymer electrolyte membranes (PEM) can play an important role in hydrogen energy transition. This work presents a study on the performance of a proton exchange membrane in the water electrolysis process at room temperature and atmospheric pressure. In the perspective of applications that need a device with small volume and low weight, a miniaturized electrolysis cell with a 36 cm2 active area of PEM over a total surface area of 76 cm2 of the device was used. H2 and O2 production rates, electrical power, energy efficiency, Faradaic efficiency and polarization curves were determined for all experiments. The effects of different parameters such as clamping pressure and materials of the electrodes on polarization phenomena were studied. The PEM used was a catalyst-coated membrane (Ir-Pt-Nafion™ 117 CCM). The maximum H2 production was about 0.02 g min−1 with a current density of 1.1 A cm−2 and a current power about 280 W. Clamping pressure and the type of electrode materials strongly influence the activation and ohmic polarization phenomena. High clamping pressure and electrodes in titanium compared to carbon electrodes improve the cell performance, and this results in lower ohmic and activation resistances.
Collapse
|
13
|
|
14
|
Drioli E, Macedonio F, Tocci E. Membrane Science and membrane Engineering for a sustainable industrial development. Sep Purif Technol 2021. [DOI: 10.1016/j.seppur.2021.119196] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
|
15
|
Large Deflection Analysis of Peripherally Fixed Circular Membranes Subjected to Liquid Weight Loading: A Refined Design Theory of Membrane Deflection-Based Rain Gauges. MATERIALS 2021; 14:ma14205992. [PMID: 34683584 PMCID: PMC8540914 DOI: 10.3390/ma14205992] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/06/2021] [Revised: 10/08/2021] [Accepted: 10/09/2021] [Indexed: 11/16/2022]
Abstract
The anticipated use of elastic membranes for deflection-based rain gauges has provided an impetus for this paper to revisit the large deflection problem of a peripherally fixed circular membrane subjected to liquid weight loading, a statics problem when the fluid–structure interaction of membrane and liquid reaches static equilibrium. The closed-form solution of this statics problem of fluid–structure interaction is necessary for the design of such membrane deflection-based rain gauges, while the existing closed-form solution, due to the use of the small rotation angle assumption of the membrane, cannot meet the design requirements for computational accuracy. In this paper, the problem under consideration is reformulated by giving up the small rotation angle assumption, which gives rise to a new and somewhat intractable nonlinear integro-differential equation of the governing out-of-plane equilibrium. The power series method has played an irreplaceable role in analytically solving membrane equations involving both integral and differential operations, and a new and more refined closed-form solution without the small rotation angle assumption is finally presented. Numerical examples conducted show that the new and more refined closed-form solution presented has satisfactory convergence, and the effect of giving up the small rotation angle assumption is also investigated numerically. The application of the closed-form solution presented in designing such membrane deflection-based rain gauges is illustrated, and the reliability of the new and more refined closed-form solution presented was confirmed by conducting a confirmatory experiment.
Collapse
|
16
|
Steady Fluid–Structure Coupling Interface of Circular Membrane under Liquid Weight Loading: Closed-Form Solution for Differential-Integral Equations. MATHEMATICS 2021. [DOI: 10.3390/math9101105] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
In this paper, the problem of fluid–structure interaction of a circular membrane under liquid weight loading is formulated and is solved analytically. The circular membrane is initially flat and works as the bottom of a cylindrical cup or bucket. The initially flat circular membrane will undergo axisymmetric deformation and deflection after a certain amount of liquid is poured into the cylindrical cup. The amount of the liquid poured determines the deformation and deflection of the circular membrane, while in turn, the deformation and deflection of the circular membrane changes the shape and distribution of the liquid poured on the deformed and deflected circular membrane, resulting in the so-called fluid-structure interaction between liquid and membrane. For a given amount of liquid, the fluid-structure interaction will eventually reach a static equilibrium and the fluid-structure coupling interface is steady, resulting in a static problem of axisymmetric deformation and deflection of the circular membrane under the weight of given liquid. The established governing equations for the static problem contain both differential operation and integral operation and the power series method plays an irreplaceable role in solving the differential-integral equations. Finally, the closed-form solutions for stress and deflection are presented and are confirmed to be convergent by the numerical examples conducted.
Collapse
|