2
|
Crönlein M, Holzapfel K, Beirer M, Postl L, Kanz KG, Pförringer D, Huber-Wagner S, Biberthaler P, Kirchhoff C. Evaluation of a new imaging tool for use with major trauma cases in the emergency department. BMC Musculoskelet Disord 2016; 17:482. [PMID: 27855665 PMCID: PMC5114770 DOI: 10.1186/s12891-016-1337-8] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/01/2016] [Accepted: 11/10/2016] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND The aim of this study was to evaluate potential benefits of a new diagnostic software prototype (Trauma Viewer, TV) automatically reformatting computed tomography (CT) data on diagnostic speed and quality, compared to CT-image data evaluation using a conventional CT console. METHODS Multiple trauma CT data sets were analysed by one expert radiology and one expert traumatology fellow independently twice, once using the TV and once using the secondary conventional CT console placed in the CT control room. Actual analysis time and precision of diagnoses assessment were evaluated. The TV and CT-console results were compared respectively, but also a comparison to the initial multiple trauma CT reports assessed by emergency radiology fellows considered as the gold standard was performed. Finally, design and function of the Trauma Viewer were evaluated in a descriptive manner. RESULTS CT data sets of 30 multiple trauma patients were enrolled. Mean time needed for analysis of one CT dataset was 2.43 min using the CT console and 3.58 min using the TV respectively. Thus, secondary conventional CT console analysis was on average 1.15 min shorter compared to the TV analysis. Both readers missed a total of 11 diagnoses using the secondary conventional CT console compared to 12 missed diagnoses using the TV. However, none of these overlooked diagnoses resulted in an Abbreviated Injury Scale (AIS) > 2 corresponding to life threatening injuries. CONCLUSIONS Even though it took the two expert fellows a little longer to analyse the CT scans on the prototype TV compared to the CT console, which can be explained by the new user interface of the TV, our preliminary results demonstrate that, after further development, the TV might serve as a new diagnostic feature in the trauma room management. Its high potential to improve time and quality of CT-based diagnoses might help in fast decision making regarding treatment of severely injured patients.
Collapse
Affiliation(s)
- Moritz Crönlein
- Department of Trauma Surgery, Klinikum rechts der Isar, Technical University of Munich, Germany, Ismaninger Strasse 22, 81675, Munich, Germany.
| | - Konstantin Holzapfel
- Department of Diagnostic and Interventional Radiology, Klinikum rechts der Isar, Technical University of Munich, Germany, Ismaninger Strasse 22, 81675, Munich, Germany
| | - Marc Beirer
- Department of Trauma Surgery, Klinikum rechts der Isar, Technical University of Munich, Germany, Ismaninger Strasse 22, 81675, Munich, Germany
| | - Lukas Postl
- Department of Oral and Maxillofacial Surgery, Kepler University Hospital, Johannes Kepler University, Krankenhausstraße 9, 4021, Linz, Austria
| | - Karl-Georg Kanz
- Department of Trauma Surgery, Klinikum rechts der Isar, Technical University of Munich, Germany, Ismaninger Strasse 22, 81675, Munich, Germany
| | - Dominik Pförringer
- Department of Trauma Surgery, Klinikum rechts der Isar, Technical University of Munich, Germany, Ismaninger Strasse 22, 81675, Munich, Germany
| | - Stefan Huber-Wagner
- Department of Trauma Surgery, Klinikum rechts der Isar, Technical University of Munich, Germany, Ismaninger Strasse 22, 81675, Munich, Germany
| | - Peter Biberthaler
- Department of Trauma Surgery, Klinikum rechts der Isar, Technical University of Munich, Germany, Ismaninger Strasse 22, 81675, Munich, Germany
| | - Chlodwig Kirchhoff
- Department of Trauma Surgery, Klinikum rechts der Isar, Technical University of Munich, Germany, Ismaninger Strasse 22, 81675, Munich, Germany
| |
Collapse
|