1
|
Bu Y, Hu Q, Xu K, Xie X, Wang S. Improved cell membrane bioaffinity sample pretreatment technique with enhanced stability for screening of potential allergenic components from traditional Chinese medicine injections. J Mater Chem B 2018; 6:624-633. [DOI: 10.1039/c7tb02768k] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
Aiming at improving reliability in conventional cell membrane chromatography, an improved bioaffinity sample pretreatment technique with enhanced stability was developed to fast screen and extract potential allergenic components from traditional Chinese medicine injections.
Collapse
Affiliation(s)
- Yusi Bu
- School of Pharmacy
- Health Science Center
- Xi’an Jiaotong University
- Xi’an 710061
- China
| | - Qi Hu
- School of Pharmacy
- Health Science Center
- Xi’an Jiaotong University
- Xi’an 710061
- China
| | - Ke Xu
- School of Pharmacy
- Health Science Center
- Xi’an Jiaotong University
- Xi’an 710061
- China
| | - Xiaoyu Xie
- School of Pharmacy
- Health Science Center
- Xi’an Jiaotong University
- Xi’an 710061
- China
| | - Sicen Wang
- School of Pharmacy
- Health Science Center
- Xi’an Jiaotong University
- Xi’an 710061
- China
| |
Collapse
|
2
|
Kang GW, Ko JH, Cheong WJ. Thermodynamic Study of Enantioseparation of Arylpropionic Acids with a Chiralcel OJ‐H Stationary Phase. J LIQ CHROMATOGR R T 2017. [DOI: 10.1081/jlc-200047202] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Affiliation(s)
- Gyoung Won Kang
- a Department of Chemistry and Institute of Basic Research , Inha University , Incheon , South Korea
| | - Joung Ho Ko
- a Department of Chemistry and Institute of Basic Research , Inha University , Incheon , South Korea
| | - Won Jo Cheong
- a Department of Chemistry and Institute of Basic Research , Inha University , Incheon , South Korea
| |
Collapse
|
3
|
Bu Y, He X, Hu Q, Wang C, Xie X, Wang S. A novel cell membrane affinity sample pretreatment technique for recognition and preconcentration of active components from traditional Chinese medicine. Sci Rep 2017; 7:3569. [PMID: 28620157 PMCID: PMC5472601 DOI: 10.1038/s41598-017-03709-6] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2017] [Accepted: 05/03/2017] [Indexed: 12/16/2022] Open
Abstract
We describe a novel biomembrane affinity sample pretreatment technique to quickly screen and preconcentrate active components from traditional Chinese medicine (TCM), which adopts cell membrane coated silica particles (CMCSPs) as affinity ligands which benefit the biomembrane's ability to maximize simulation of drug-receptor interactions in vivo. In this study, the prepared CMCSPs formed by irreversible adsorption of fibroblast growth factor receptor 4 (FGFR4) cell membrane on the surface of silica were characterized using different spectroscopic and imaging instruments. Drug binding experiments showed the excellent adsorption rate and adsorption capacity of FGFR4/CMCSPs compared with non-coated silica particles. The FGFR4/CMCSPs were used as solid-phase extraction sorbents to pretreat the TCM Aconitum szechenyianum Gay. The resultant FGFR4/CMCSPs exhibited good performance. In addition, high selectivity and recognition ability of the FGFR4/CMCSPs were determined by selectivity experiments. Four alkaloid were screened and identified, one of these alkaloid, napellonine, showed favorable anti-tumor activity in preliminary pharmacological verification trials including cell proliferation and molecular docking assays. The proposed cell membrane affinity sample pretreatment method is a reliable, effective and time-saving method for fast screening and enriching active compounds and can be extended to pretreat other TCMs as leading compounds resources.
Collapse
Affiliation(s)
- Yusi Bu
- School of Pharmacy, Health Science Center, Xi'an Jiaotong University, Xi'an, 710061, China.,Shaanxi Engineering Research Center of Cardiovascular Drugs Screening & Analysis, Xi'an, 710061, China
| | - Xiaoshuang He
- School of Pharmacy, Health Science Center, Xi'an Jiaotong University, Xi'an, 710061, China.,Shaanxi Engineering Research Center of Cardiovascular Drugs Screening & Analysis, Xi'an, 710061, China
| | - Qi Hu
- School of Pharmacy, Health Science Center, Xi'an Jiaotong University, Xi'an, 710061, China.,Shaanxi Engineering Research Center of Cardiovascular Drugs Screening & Analysis, Xi'an, 710061, China
| | - Cheng Wang
- School of Pharmacy, Health Science Center, Xi'an Jiaotong University, Xi'an, 710061, China
| | - Xiaoyu Xie
- School of Pharmacy, Health Science Center, Xi'an Jiaotong University, Xi'an, 710061, China. .,Shaanxi Engineering Research Center of Cardiovascular Drugs Screening & Analysis, Xi'an, 710061, China.
| | - Sicen Wang
- School of Pharmacy, Health Science Center, Xi'an Jiaotong University, Xi'an, 710061, China. .,Shaanxi Engineering Research Center of Cardiovascular Drugs Screening & Analysis, Xi'an, 710061, China.
| |
Collapse
|
4
|
Barbosa AF, Barbosa VMP, Bettini J, Luccas PO, Figueiredo EC. Restricted access carbon nanotubes for direct extraction of cadmium from human serum samples followed by atomic absorption spectrometry analysis. Talanta 2014; 131:213-20. [PMID: 25281095 DOI: 10.1016/j.talanta.2014.07.051] [Citation(s) in RCA: 36] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2014] [Revised: 07/17/2014] [Accepted: 07/20/2014] [Indexed: 10/25/2022]
Abstract
In this paper, we propose a new sorbent that is able to extract metal ions directly from untreated biological fluids, simultaneously excluding all proteins from these samples. The sorbent was obtained through the modification of carbon nanotubes (CNTs) with an external bovine serum albumin (BSA) layer, resulting in restricted access carbon nanotubes (RACNTs). The BSA layer was fixed through the interconnection between the amine groups of the BSA using glutaraldehyde as cross-linker. When a protein sample is percolated through a cartridge containing RACNTs and the sample pH is higher than the isoelectric point of the proteins, both proteins from the sample and the BSA layer are negatively ionized. Thus, an electrostatic repulsion prevents the interaction between the proteins from the sample on the RACNTs surface. At the same time, metal ions are adsorbed in the CNTs (core) after their passage through the chains of proteins. The Cd(2+) ion was selected for a proof-of-principle case to test the suitability of the RACNTs due to its toxicological relevance. RACNTs were able to extract Cd(2+) and exclude almost 100% of the proteins from the human serum samples in an online solid-phase extraction system coupled with thermospray flame furnace atomic absorption spectrometry. The limits of detection and quantification were 0.24 and 0.80 μg L(-1), respectively. The sampling frequency was 8.6h(-1), and the intra- and inter-day precisions at the 0.80, 15.0, and 30.0 μg L(-1) Cd(2+) levels were all lower than 10.1% (RSD). The recoveries obtained for human blood serum samples fortified with Cd(2+) ranged from 85.0% to 112.0%. The method was successfully applied to analyze Cd(2+) directly from six human blood serum samples without any pretreatment, and the observed concentrations ranged from <LOQ to 2.52 µg L(-1).
Collapse
Affiliation(s)
- Adriano F Barbosa
- Laboratory of Toxicant and Drug Analysis - LATF, Gabriel Monteiro da Silva St. 700, Federal University of Alfenas - Unifal-MG, 37130-000 Alfenas, MG, Brazil; Institute of Chemistry, Gabriel Monteiro da Silva St. 700, Federal University of Alfenas - Unifal-MG, 37130-000 Alfenas, MG, Brazil
| | - Valéria M P Barbosa
- Laboratory of Toxicant and Drug Analysis - LATF, Gabriel Monteiro da Silva St. 700, Federal University of Alfenas - Unifal-MG, 37130-000 Alfenas, MG, Brazil; Institute of Chemistry, Gabriel Monteiro da Silva St. 700, Federal University of Alfenas - Unifal-MG, 37130-000 Alfenas, MG, Brazil
| | - Jefferson Bettini
- Brazilian Nanotechnology National Laboratory, 13083-970 Campinas, SP, Brazil
| | - Pedro O Luccas
- Institute of Chemistry, Gabriel Monteiro da Silva St. 700, Federal University of Alfenas - Unifal-MG, 37130-000 Alfenas, MG, Brazil
| | - Eduardo C Figueiredo
- Laboratory of Toxicant and Drug Analysis - LATF, Gabriel Monteiro da Silva St. 700, Federal University of Alfenas - Unifal-MG, 37130-000 Alfenas, MG, Brazil.
| |
Collapse
|
5
|
Yang SH, Fan H, Classon RJ, Schug KA. Restricted access media as a streamlined approach toward on-line sample preparation: Recent advancements and applications. J Sep Sci 2013; 36:2922-38. [DOI: 10.1002/jssc.201300595] [Citation(s) in RCA: 54] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2013] [Revised: 06/16/2013] [Accepted: 06/21/2013] [Indexed: 01/22/2023]
Affiliation(s)
- Samuel H. Yang
- Department of Chemistry and Biochemistry; The University of Texas at Arlington; Arlington TX USA
| | - Hui Fan
- Department of Chemistry and Biochemistry; The University of Texas at Arlington; Arlington TX USA
| | | | - Kevin A. Schug
- Department of Chemistry and Biochemistry; The University of Texas at Arlington; Arlington TX USA
| |
Collapse
|
6
|
Medvedovici A, Albu F, David V. HANDLING DRAWBACKS OF MASS SPECTROMETRIC DETECTION COUPLED TO LIQUID CHROMATOGRAPHY IN BIOANALYSIS. J LIQ CHROMATOGR R T 2010. [DOI: 10.1080/10826076.2010.484375] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Affiliation(s)
- Andrei Medvedovici
- a Department of Analytical Chemistry, Faculty of Chemistry , University of Bucharest , Bucharest , Romania
| | - Florin Albu
- b Bioanalytical Laboratory , S.C. LaborMed Pharma S.A. , Bucharest , Romania
| | - Victor David
- a Department of Analytical Chemistry, Faculty of Chemistry , University of Bucharest , Bucharest , Romania
| |
Collapse
|
7
|
Rodríguez-Gonzalo E, García-Gómez D, Herrero-Hernández E, Carabias-Martínez R. Automated sample treatment with the injection of large sample volumes for the determination of contaminants and metabolites in urine. J Sep Sci 2010; 33:2240-9. [DOI: 10.1002/jssc.201000202] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
8
|
Albu F, Sora I, Tache F, David V, Medvedovici A. On-Line SPE on Restricted Access Adsorbent for HPLC-MS/MS Analysis of Felodipine in Plasma Samples. ANAL LETT 2010. [DOI: 10.1080/00032710903518740] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
9
|
Felix G, Berthod A. Part II: From Dermatologicals to Sensory Organ and Various Drugs. SEPARATION AND PURIFICATION REVIEWS 2008. [DOI: 10.1080/15422110701873007] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|
10
|
Kang GW, Ko JH, Cheong WJ. Thermodynamic Study of Enantioseparation of Arylpropionic Acids with the Chirex 3001 Stationary Phase. J LIQ CHROMATOGR R T 2007. [DOI: 10.1081/jlc-120028251] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Affiliation(s)
- Gyoung Won Kang
- a Department of Chemistry, Institute for Basic Research , Inha University , Incheon , 402‐751 , South Korea
| | - Joung Ho Ko
- a Department of Chemistry, Institute for Basic Research , Inha University , Incheon , 402‐751 , South Korea
| | - Won Jo Cheong
- a Department of Chemistry, Institute for Basic Research , Inha University , Incheon , 402‐751 , South Korea
| |
Collapse
|
11
|
Sadílek P, Šatínský D, Solich P. Using restricted-access materials and column switching in high-performance liquid chromatography for direct analysis of biologically-active compounds in complex matrices. Trends Analyt Chem 2007. [DOI: 10.1016/j.trac.2007.02.002] [Citation(s) in RCA: 103] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
12
|
Mullett WM. Determination of drugs in biological fluids by direct injection of samples for liquid-chromatographic analysis. ACTA ACUST UNITED AC 2007; 70:263-73. [DOI: 10.1016/j.jbbm.2006.10.001] [Citation(s) in RCA: 74] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2006] [Accepted: 10/05/2006] [Indexed: 10/24/2022]
|
13
|
Vázquez PP, Fernández JM, Gil García MD. DETERMINATION OF AZOLE PESTICIDES IN HUMAN SERUM BY COUPLED COLUMN REVERSED-PHASE LIQUID CHROMATOGRAPHY USING ULTRAVIOLET ABSORBANCE AND MASS SPECTROMETRIC DETECTION. J LIQ CHROMATOGR R T 2007. [DOI: 10.1081/jlc-120015890] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
|
14
|
Choi SO, Um SY, Jung SH, Jung SJ, Kim JI, Lee HJ, Chung SY. Column-switching high-performance liquid chromatographic method for the determination of zaltoprofen in rat plasma. J Chromatogr B Analyt Technol Biomed Life Sci 2006; 830:301-5. [PMID: 16309979 DOI: 10.1016/j.jchromb.2005.11.003] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2004] [Revised: 07/13/2005] [Accepted: 11/05/2005] [Indexed: 11/16/2022]
Abstract
A direct injection column-switching high-performance liquid chromatography (HPLC) method was developed and validated for quantification of zaltoprofen in rat plasma. Following dilution with mobile phase A, i.e. acetonitrile-10mM potassium phosphate buffer (pH 6.8) (12:88, v/v) samples were directly injected to the pre-column without sample pre-purification step. After endogenous plasma components were eluted to waste, the system was switched and the analyte was eluted to the trap column. Zaltoprofen was then back-flushed to the analytical column for separation with mobile phase B, i.e. acetonitrile-10mM potassium phosphate buffer (pH 6.8) (35:65, v/v) and quantification with an ultraviolet detector at 230 nm. The calibration curve was linear in the concentration range of 40-5000 ngmL(-1). This method has been fully validated and shown to be specific, accurate and precise. The method is simple, rapid and the sample preparation is minimal and appears to be useful for the pharmacokinetic study of zaltoprofen.
Collapse
Affiliation(s)
- Sun Ok Choi
- Division of Biopharmaceutics, Department of Pharmacology, National Institute of Toxicological Research, Korea Food and Drug Administration, Nokbun-dong 5, Eunpyung-Ku, Seoul, South Korea.
| | | | | | | | | | | | | |
Collapse
|
15
|
Vander Heyden Y, Mangelings D, Matthijs N, Perrin C. 18 Chiral separations. SEP SCI TECHNOL 2005. [DOI: 10.1016/s0149-6395(05)80062-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|
16
|
Berna MJ, Ackermann BL, Murphy AT. High-throughput chromatographic approaches to liquid chromatographic/tandem mass spectrometric bioanalysis to support drug discovery and development. Anal Chim Acta 2004. [DOI: 10.1016/j.aca.2003.12.023] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
17
|
Souverain S, Rudaz S, Veuthey JL. Restricted access materials and large particle supports for on-line sample preparation: an attractive approach for biological fluids analysis. J Chromatogr B Analyt Technol Biomed Life Sci 2004; 801:141-56. [PMID: 14751782 DOI: 10.1016/j.jchromb.2003.11.043] [Citation(s) in RCA: 213] [Impact Index Per Article: 10.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
An analytical process generally involves four main steps: (1) sample preparation; (2) analytical separation; (3) detection; and (4) data handling. In the bioanalytical field, sample preparation is often considered as the time-limiting step. Indeed, the extraction techniques commonly used for biological matrices such as liquid-liquid extraction (LLE) and solid-phase extraction (SPE) are achieved in the off-line mode. In order to perform a high throughput analysis, efforts have been engaged in developing a faster sample purification process. Among different strategies, the introduction of special extraction sorbents, such as the restricted access media (RAM) and large particle supports (LPS), allowing the direct and repetitive injection of complex biological matrices, represents a very attractive approach. Integrated in a liquid chromatography (LC) system, these extraction supports lead to the automation, simplification and speeding up of the sample preparation process. In this paper, RAM and LPS are reviewed and particular attention is given to commercially available supports. Applications of these extraction supports, are presented in single column and column-switching configurations, for the direct analysis of compounds in various biological fluids.
Collapse
Affiliation(s)
- S Souverain
- Laboratory of Pharmaceutical Analytical Chemistry, School of Pharmacy, University of Geneva, 20 Bd. d'Yvoy, 12114 Geneva, Switzerland
| | | | | |
Collapse
|
18
|
Rbeida O, Christiaens B, Hubert P, Lubda D, Boos KS, Crommen J, Chiap P. Evaluation of a novel anion-exchange restricted-access sorbent for on-line sample clean-up prior to the determination of acidic compounds in plasma by liquid chromatography. J Chromatogr A 2004; 1030:95-102. [PMID: 15043258 DOI: 10.1016/j.chroma.2003.11.031] [Citation(s) in RCA: 41] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
A new kind of silica-based restricted-access material (RAM) with anionic properties has been tested in pre-columns for on-line solid-phase extraction of acidic compounds from directly injected plasma samples prior to their determination by reversed-phase liquid chromatography (LC), using the column-switching technique. The outer surface of the porous RAM particles contains hydrophilic diol groups while diethylaminoethyl (DEAE) groups are bound to the internal surface which gives the sorbent the properties of a weak anion exchanger towards low-molecular-mass compounds. Due to an appropriate pore diameter (about 6 nm), macromolecules, such as proteins, are physically excluded from the pores and flushed directly out during the sample clean-up process, while small compounds have access to the inner surface and can be retained mainly by electrostatic interactions. The retention capability of this novel packing material has been tested for some hydrophilic acidic compounds such as aspartic acid, glutamic acid, ascorbic acid and acetylcysteine as well as for some more hydrophobic drugs such as naproxen, ibuprofen and diclofenac, used as model compounds. The influence of the composition of the washing liquid on the retention of the analytes in the pre-column has been investigated. The efficiency of the sorbent to clean-up complex matrices was also tested using human plasma and urine samples. A generic washing liquid composition was then selected in order to obtain efficient and selective sample clean-up as well as a high recovery of the acidic analytes.
Collapse
Affiliation(s)
- O Rbeida
- Department of Analytical Pharmaceutical Chemistry, Institute of Pharmacy, University of Liège, CHU, B36, B-4000 Liège 1, Belgium
| | | | | | | | | | | | | |
Collapse
|
19
|
Millot MC. Separation of drug enantiomers by liquid chromatography and capillary electrophoresis, using immobilized proteins as chiral selectors. J Chromatogr B Analyt Technol Biomed Life Sci 2003; 797:131-59. [PMID: 14630147 DOI: 10.1016/j.jchromb.2003.08.035] [Citation(s) in RCA: 107] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
Proteins display interesting chiral discrimination properties owing to multiple possibilities of intermolecular interactions with chiral compounds. This review deals with proteins which have been used as immobilized chiral selectors for the enantioseparation of drugs in liquid chromatography and capillary electrophoresis. The main procedures allowing the immobilization of proteins onto matrices, such as silica and zirconia particles, membranes and capillaries are first presented. Then the factors affecting the enantioseparation of drugs in liquid chromatography, using various protein-based chiral stationary phases (CSPs), are reviewed and discussed. Last, chiral separations already achieved using immobilized protein selectors in affinity capillary electrochromatography (ACEC) are presented and compared in terms of efficiency, stability and reproducibility.
Collapse
Affiliation(s)
- M C Millot
- Laboratoire de Recherche sur les Polymères, CNRS-Université Paris 12, UMR 7581, 2 à 8 rue Henri Dunant, Thiais 94320, France.
| |
Collapse
|
20
|
Misl'anová C, Hutta M. Role of biological matrices during the analysis of chiral drugs by liquid chromatography. J Chromatogr B Analyt Technol Biomed Life Sci 2003; 797:91-109. [PMID: 14630145 DOI: 10.1016/j.jchromb.2003.07.018] [Citation(s) in RCA: 34] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
The review article covers advances of chiral drugs analysis by high-performance liquid chromatography (HPLC) methods achieved during last 10 years. Emphasis is given to various aspects of influence of biological matrix in pharmacodynamics, pharmacokinetics, HPLC analysis. Discussed is composition of main biological matrices from the point of view of potential interferences to above-mentioned fields of study. Beside typical analytical approaches to chiral recognition in HPLC, sample pretreatment and/or clean-up by conventional extraction procedures, column switching (CSW) techniques using restricted access materials (RAMs), microdialysis (MCD) is discussed. Measurement of unbound drug concentration and discussion of column maintenance and remedy is an additional source of information and field where knowledge on complex properties and interactions of biological matrix is usefully applicable.
Collapse
Affiliation(s)
- Csilla Misl'anová
- Institute of Preventive and Clinical Medicine, Limbová 14, SK-833 01 37 Bratislava, Slovak Republic.
| | | |
Collapse
|
21
|
Christiaens B, Chiap P, Rbeida O, Cello D, Crommen J, Hubert P. Fully automated method for the liquid chromatographic determination of cyproterone acetate in plasma using restricted access material for sample pre-treatment. J Chromatogr B Analyt Technol Biomed Life Sci 2003; 795:73-82. [PMID: 12957171 DOI: 10.1016/s1570-0232(03)00517-8] [Citation(s) in RCA: 18] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
A new fully automated method for the quantitative analysis of an antiandrogenic substance, cyproterone acetate (CPA), in plasma samples has been developed using on-line solid-phase extraction (SPE) prior to the determination by reversed-phase liquid chromatography (LC). The automated method was based on the use of a precolumn packed with an internal-surface reversed-phase packing material (LiChrospher RP-4 ADS) for sample clean-up coupled to LC analysis on an octadecyl stationary phase using a column-switching system. A 200-microL volume of plasma sample was injected directly on the precolumn packed with restricted access material using a mixture of water-acetonitrile (90:10, v/v) as washing liquid. The analyte was then eluted in the back-flush mode with the LC mobile phase which consisted of a mixture of phosphate buffer, pH 7.0-acetonitrile (54:46, v/v). The elution profiles of CPA and blank plasma samples on the precolumn and the time needed for analyte transfer from the precolumn to the analytical column were determined. Different compositions of washing liquid and mobile phase were tested to reduce the interference of plasma endogenous components. UV detection was achieved at 280 nm. Finally, the developed method was validated using a new approach, namely the application of the accuracy profile based on the interval confidence at 90% of the total measurement error (bias+standard deviation). The limit of quantification of cyproterone acetate in plasma was determined at 15 ng mL(-1). The validated method should be applicable to the determination of CPA in patients treated by at least 50 mg day(-1).
Collapse
Affiliation(s)
- B Christiaens
- Institute of Pharmacy, University of Liège, B-4000 1 Liège, Belgium
| | | | | | | | | | | |
Collapse
|
22
|
Baeyens WRG, Van der Weken G, D'haeninck E, García-Campaña AM, Vankeirsbilck T, Vercauteren A, Deprez P. Application of an alkyl-diol silica precolumn in a column-switching system for the determination of meloxicam in plasma. J Pharm Biomed Anal 2003; 32:839-46. [PMID: 12899970 DOI: 10.1016/s0731-7085(03)00251-6] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
The group of LiChrospher alkyl-diol silica (ADS) phases that make part of the unique family of restricted-access materials, have been developed as special packings used in the liquid chromatographic integrated sample processing of biofluids. The advantage of these phases lies in the possibility of direct injection of untreated plasma. An on-line elimination of the protein matrix is achieved with a quantitative recovery together with an on-column enrichment. The present method describes a hand-operated on-line switching high-performance liquid chromatographic system for the determination of meloxicam. Spiked plasma samples were introduced on the ADS precolumn using a 0.05 M phosphate buffer, pH 6.0. After washing with the buffer the ADS column was backflushed with the mobile phase 0.05 M phosphate buffer-30% (v/v) acetonitrile (ACN)-25 mM t-butylamine (TBA) at a pH of 7.0, thus transferring the analyte to the analytical column LiChrocart 125-4 LiChrospher RP-8. The eluent was monitored by a UV-detector set at 364 nm. The developed column-switching method is fully applicable to plasma injections.
Collapse
Affiliation(s)
- W R G Baeyens
- Department of Pharmaceutical Analysis, Faculty of Pharmaceutical Sciences, Ghent University, Harelbekestraat 72, B-9000 Ghent, Belgium.
| | | | | | | | | | | | | |
Collapse
|
23
|
Hsieh Y, Wang G, Wang Y, Chackalamannil S, Korfmacher WA. Direct plasma analysis of drug compounds using monolithic column liquid chromatography and tandem mass spectrometry. Anal Chem 2003; 75:1812-8. [PMID: 12713038 DOI: 10.1021/ac020630e] [Citation(s) in RCA: 49] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
A monolithic silica column high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method has been developed for the high-speed direct simultaneous determination of a drug discovery compound and its major circulating metabolite (M-72) in rat plasma. This methodology makes use of flow programming and an alkyl-bonded silica rod column for fast macromolecule removal and chromatographic separation without the need for significant sample preparation. The matrix ionization suppression effect on the monolithic column HPLC-MS/MS system was investigated using the postcolumn infusion technique. After 200 plasma injections on a 50 x 4.6 mm monolithic silica column, consistent column efficiency of close to 39,000 theoretical plates/m and reproducible retention times for the analytes were observed. The apparent on-column recoveries of 12 test compounds in rat plasma samples were greater than 90%. The proposed fast direct plasma injection method was tested over a 3-day period with the interday coefficient of variation less than 15% for both analytes.
Collapse
Affiliation(s)
- Yunsheng Hsieh
- Drug Metabolism and Pharmacokinetics Department, Schering-Plough Research Institute, Kenilworth, New Jersey 07033, USA.
| | | | | | | | | |
Collapse
|
24
|
Mullett WM, Pawliszyn J. The development of selective and biocompatible coatings for solid phase microextraction. J Sep Sci 2003. [DOI: 10.1002/jssc.200390031] [Citation(s) in RCA: 64] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
25
|
Souverain S, Eap C, Veuthey JL, Rudaz S. Automated LC-MS Method for the Fast Stereoselective Determination of Methadone in Plasma. Clin Chem Lab Med 2003; 41:1615-21. [PMID: 14708886 DOI: 10.1515/cclm.2003.245] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Methadone (MTD) is a chiral drug widely used for the treatment of opioid dependence for which a rapid analytical method for the determination of each enantiomer would be advantageous. In order to improve method sensitivity and to automate the entire analytical process, a column-switching configuration has been developed. An online extraction system coupled to a cellulose-based chiral stationary phase (CSP), namely Chiralcel OJ-R, was used and detection was performed by mass spectrometry. Fifty microl of plasma were injected into the liquid chromatography-mass spectrometry (LC-MS) system after addition of acetonitrile (ACN) containing methadone deuterated D9 (MTD-D9) (internal standard) and centrifugation. For the rapid extraction step, a large particle size support was selected. A baseline separation of MTD enantiomers was obtained in less than 12 min. Trueness and precision were evaluated with control samples at 500 ng/ml of (R,S)-methadone. Trueness values were 106.6% and 103.0% for (R)-MTD and (S)-MTD, respectively, with a coefficient of variation inferior to 2.5% for both compounds. Finally, a good concordance was found using this method for analysis of plasma samples from patients in maintenance treatment as compared to a previously described HPLC-UV method after liquid-liquid extraction.
Collapse
Affiliation(s)
- Sandrine Souverain
- Laboratory of Analytical Pharmaceutical Chemistry, School of Pharmacy, University of Geneva, Geneva, Switzerland
| | | | | | | |
Collapse
|
26
|
Chiap P, Rbeida O, Christiaens B, Hubert P, Lubda D, Boos KS, Crommen J. Use of a novel cation-exchange restricted-access material for automated sample clean-up prior to the determination of basic drugs in plasma by liquid chromatography. J Chromatogr A 2002; 975:145-55. [PMID: 12458755 DOI: 10.1016/s0021-9673(02)01334-1] [Citation(s) in RCA: 58] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
A new kind of silica-based restricted-access material (RAM) has been tested in pre-columns for the on-line solid-phase extraction (SPE) of basic drugs from directly injected plasma samples before their quantitative analysis by reversed-phase liquid chromatography (LC), using the column switching technique. The outer surface of the porous RAM particlescontains hydrophilic diol groups while sulphonic acid groups are bound to the internal surface, which gives the sorbent the properties of a strong cation exchanger towards low molecular mass compounds. Macromolecules such as proteins have no access to the internal surface of the pre-column due to their exclusion from the pores and are then flushed directly out. The retention capability of this novel packing material has been tested for some hydrophilic basic drugs, such as atropine, fenoterol, ipratropium, procaine, sotalol and terbutaline, used as model compounds. The influence of the composition of the washing liquid on the retention of the analytes in the pre-column has been investigated. The elution profiles of the different compounds and the plasma matrix as well as the time needed for the transfer of the analytes from the pre-column to the analytical column were determined in order to deduce the most suitable conditions for the clean-up step and develop on-line methods for the LC determination of these compounds in plasma. The cationic exchange sorbent was also compared to another RAM, namely RP-18 ADS (alkyl diol silica) sorbent with respect to retention capability towards basic analytes.
Collapse
Affiliation(s)
- P Chiap
- Department of Analytical Pharmaceutical Chemistry, Institute of Pharmacy, University of Liège, CHU-B36, B-400 Liège 1, Belgium
| | | | | | | | | | | | | |
Collapse
|
27
|
Schlauch M, Fulde K, Frahm AW. Enantioselective determination of (R)- and (S)-sotalol in human plasma by on-line coupling of a restricted-access material precolumn to a cellobiohydrolase I-based chiral stationary phase. J Chromatogr B Analyt Technol Biomed Life Sci 2002; 775:197-207. [PMID: 12113986 DOI: 10.1016/s1570-0232(02)00287-8] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
A liquid chromatographic column-switching method for the enantioselective determination of (RS)-sotalol in plasma was developed and validated. The method is based on the on-line coupling of a precolumn filled with the restricted access material LiChrospher ADS to a cellobiohydrolase I-based chiral stationary phase (CSP). The plasma samples were injected onto the precolumn using a mobile phase containing 1% methanol in 10 mM phosphate buffer at pH 7.4 for 10 min for the removal of matrix components. The analytes were transferred to the CSP for their enantiomeric separation by backflushing the precolumn with 15% 2-propanol in 10 mM phosphate buffer (pH 7.0) including 0.05 mM EDTA. The quantitative determination of the sotalol enantiomers was possible upon addition of the internal standard (S)-atenolol. The method was validated showing a good linearity in the concentration range from 25 to 1000 microg l(-1) for each enantiomer. The average values of the intra- and inter-day variability were 1.17% and 3.42%, respectively, for (R)-sotalol and 1.24% and 1.99%, respectively, for (S)-sotalol. The applicability of the method to real world samples has been proven by means of two pharmacokinetic studies. They revealed that the pharmacokinetic properties of the sotalol enantiomers do not differ significantly neither for healthy young volunteers after single dose application nor for elder patients in the steady state.
Collapse
Affiliation(s)
- Michael Schlauch
- Department of Pharmaceutical Chemistry, Albert-Ludwigs-University, Albertstr. 25, D-79104 Freiburg im Breisgau, Germany
| | | | | |
Collapse
|
28
|
Szymura-Oleksiak J, Bojarski J, Aboul-Enein HY. Recent applications of stereoselective chromatography. Chirality 2002; 14:417-35. [PMID: 11984758 DOI: 10.1002/chir.10110] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Some recent applications of stereoselective chromatography in the fields of clinical pharmacy, drug analysis, food, and natural products are reviewed. The review is documented with up-to-date literature, which will assist further expansion of research in these areas.
Collapse
Affiliation(s)
- Joanna Szymura-Oleksiak
- Department of Pharmacokinetics and Physical Pharmacy, Medical College, Jagiellonian University, Krakow, Poland
| | | | | |
Collapse
|
29
|
Haginaka J. Pharmaceutical and biomedical applications of enantioseparations using liquid chromatographic techniques. J Pharm Biomed Anal 2002; 27:357-72. [PMID: 11755739 DOI: 10.1016/s0731-7085(01)00652-5] [Citation(s) in RCA: 52] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
Abstract
The chiral separation methods using liquid chromatographic techniques can be divided into two categories: one is a direct method, which is based on a diastereomer formation on stationary phase or in mobile phase. The other is an indirect method, which is based on a diasteromer formation by reaction with a homochiral reagent. The enantiomer separation on a chiral stationary phases followed by derivatization with an achiral reagent is also dealt with this review article as the indirect method. The pharmaceutical and biomedical applications of enantioseparations using the direct and indirect methods have been considered in this review.
Collapse
Affiliation(s)
- Jun Haginaka
- Faculty of Pharmaceutical Sciences, Mukogawa Women's University, 11-68, Koshien Kyuban-cho, Nishinomiya, Hyogo 663-8179, Japan.
| |
Collapse
|
30
|
Chiap P, Ceccato A, Gora R, Hubert P, Géczy J, Crommen J. Automated determination of pirlindole enantiomers in plasma by on-line coupling of a pre-column packed with restricted access material to a chiral liquid chromatographic column. J Pharm Biomed Anal 2002; 27:447-55. [PMID: 11755746 DOI: 10.1016/s0731-7085(01)00647-1] [Citation(s) in RCA: 20] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
A fully automated liquid chromatographic method has been developed for the determination of the enantiomers of pirlindole, an antidepressant drug, in human plasma. The method is based on the use of a pre-column packed with restricted access material (RAM) (LiChrospher ADS RP-4) for sample clean-up coupled to a column containing a cellulose tris-(3,5-dimethylphenylcarbamate) based chiral stationary phase (Chiralcel OD-R) for the separation and quantitative analysis of pirlindole enantiomers. A 50-microl plasma volume was injected directly onto the pre-column using a mixture of phosphate buffer (pH 5.0) and methanol (97:3; v/v) as washing liquid. By rotation of a switching valve, the analytes were then eluted in the back-flush mode with the LC mobile phase. A complete separation of pirlindole enantiomers was obtained in 22 min on the Chiralcel OD-R column, using a mobile phase made of a mixture of phosphate buffer (pH 5.0) containing 50 mM sodium perchlorate and acetonitrile (65:35; v/v). The flow-rate was 0.6 ml/min and the analytes were detected fluorometrically using 295 and 340 nm as excitation and emission wavelengths, respectively. The method was then validated and was found to be linear in the 2.5-200 ng/ml range. The limit of detection was lower than 1 ng/ml. Repeatability and intermediate precision at a concentration of 50 ng/ml were about 1.5 and 3.5%, respectively.
Collapse
Affiliation(s)
- P Chiap
- Department of Analytical Pharmaceutical Chemistry, Institute of Pharmacy, University of Liège, CHU, B36, B-4000 Liège 1, Belgium
| | | | | | | | | | | |
Collapse
|
31
|
Mislanová C, Hutta M. Influence of various biological matrices (plasma, blood microdialysate) on chromatographic performance in the determination of beta-blockers using an alkyl-diol silica precolumn for sample clean-up. JOURNAL OF CHROMATOGRAPHY. B, BIOMEDICAL SCIENCES AND APPLICATIONS 2001; 765:167-77. [PMID: 11767310 DOI: 10.1016/s0378-4347(01)00423-6] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
A HPLC column-switching system with LiChrospher RP-8 ADS precolumn was applied for the determination of beta-blockers (atenolol, pindolol, propranolol) in human plasma. The influence of biological matrices on the changes of the chromatographic parameters such as retention time, peak symmetry, area and selectivity were investigated. After injection of 5 ml plasma a decrease of retention times of the analytes was observed of up to 25% and an increase of asymmetry factors of up to 5%. Peak areas and selectivities were not changed. The observed effect could indicate changes of chromatographic performance caused by contributions of the analytical column or the ADS precolumn. The experiments with microdialysis excluded the contribution of the analytical column. A detailed investigation of experiments have been discussed in this paper.
Collapse
Affiliation(s)
- C Mislanová
- Institute of Preventive and Clinical Medicine, Bratislava, Slovak Republic.
| | | |
Collapse
|
32
|
Keski-Hynnilä H, Raanaa K, Forsberg M, Männistö P, Taskinen J, Kostiainen R. Quantitation of entacapone glucuronide in rat plasma by on-line coupled restricted access media column and liquid chromatography-tandem mass spectrometry. JOURNAL OF CHROMATOGRAPHY. B, BIOMEDICAL SCIENCES AND APPLICATIONS 2001; 759:227-36. [PMID: 11499476 DOI: 10.1016/s0378-4347(01)00226-2] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
A column-switching liquid chromatography-electrospray ionization-tandem mass spectrometric (LC-ESI-MS-MS) method was developed for the direct analysis of entacapone glucuronide in plasma. The plasma samples (5 microl) were injected onto a C18-alkyl-diol silica (ADS) column and the matrix compounds were washed to waste with a mixture of 20 mM ammonium acetate solution at pH 4.0-acetonitrile (97:3). The retained analyte fraction containing (E)- and (Z)-isomers of glucuronides of entacapone and tolcapone glucuronide (internal standard) was backflushed to the analytical C18 column, with a mixture of 20 mM ammonium acetate-acetonitrile (85:15) for the final separation at pH 7.0. The eluate was directed to the mass spectrometer after splitting (1:100). The mass spectrometer was operated in the negative ion mode and the deprotonated molecules [M-H]- were chosen as precursor ions for the analytes and internal standard. Collisionally induced dissociation of [M-H] in MS-MS resulted in loss of the neutral glucuronide moiety and in the appearance of intensive negatively charged aglycones [M-H-Glu]-, which were chosen as the product ions for single reaction monitoring. Quantitative studies showed a wide dynamic range (0.0025-100 microg/ml) with correlation coefficients better than 0.995. The method was repeatable within-day (relative standard deviation, RSD<7%) and between-day (RSD<14%) and the recovery (78-103%) was better than with the traditional, laborious pretreatment method. The use of tandem mass spectrometry permitted low limits of detection (1 ng/ml of entacapone glucuronide). The method was applied for the quantitation of (E)- and (Z)-isomers of entacapone glucuronide in plasma of rats used in absorption studies.
Collapse
|
33
|
Waksmundzka-Hajnos M, Petruczynik A, Hawryl A. Comparison of chromatographic properties of cyanopropyl-, diol- and aminopropyl- polar-bonded stationary phases by the retention of model compounds in normal-phase liquid chromatography systems. J Chromatogr A 2001; 919:39-50. [PMID: 11459310 DOI: 10.1016/s0021-9673(01)00796-8] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Polar-bonded stationary phases, such as CN-, diol- and NH2-silica, have been characterised by the retention of model solutes (phenols, aromatic amines and quinoline bases) in normal-phase systems using n-heptane--polar modifier (2-propanol, tetrahydrofuran or dioxane) mixtures as eluents. The selectivity of separation for the particular groups of substances has been analysed by the log kI versus log kII relationships for CN- and diol, CN- and NH2- and NH2- and diol phases in examined eluent systems by the plotting of correlation lines. The values of regression coefficient r indicate either the similarity of the retention mechanisms of model solutes in some examined systems where r>0.9, or differences among various systems where r<<0.9. The values of slopes of correlation lines show the selectivity of separation for particular group of compounds. The selectivity of separation has also been characterised by deltalog k values. The effect of modifier (2-propanol, tetrahydrofuran and dioxane) on selectivity of model solutes on these phases has also been discussed.
Collapse
Affiliation(s)
- M Waksmundzka-Hajnos
- Department of Inorganic and Analytical Chemistry, Medical University, Lublin, Poland.
| | | | | |
Collapse
|
34
|
Application of restricted-access media column in coupled-column RPLC with UV detection and electrospray mass spectrometry for determination of azole pesticides in urine. Chromatographia 2001. [DOI: 10.1007/bf02491612] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
|
35
|
Gilar M, Bouvier ES, Compton BJ. Advances in sample preparation in electromigration, chromatographic and mass spectrometric separation methods. J Chromatogr A 2001; 909:111-35. [PMID: 11269513 DOI: 10.1016/s0021-9673(00)01108-0] [Citation(s) in RCA: 91] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
The quality of sample preparation is a key factor in determining the success of analysis. While analysis of pharmaceutically important compounds in biological matrixes has driven forward the development of sample clean-up procedures in last 20 years, today's chemists face an additional challenge: sample preparation and analysis of complex biochemical samples for characterization of genotypic or phenotypic information contained in DNA and proteins. This review focuses on various sample pretreatment methods designed to meet the requirements for the analysis of biopolymers and small drugs in complex matrices. We discuss the advances in development of solid-phase extraction (SPE) sorbents, on-line SPE, membrane-based sample preparation, and sample clean-up of biopolymers prior to their analysis by mass spectrometry.
Collapse
Affiliation(s)
- M Gilar
- Waters Corp., Milford, MA 01757, USA.
| | | | | |
Collapse
|