1
|
Zhang X, Shi J, Wu X, Li L, Sun W, Zou Y, Chen G, Wu S, Duan S. Dosimetric Comparison of Commonly Used Volumetric Modulated Arc Therapy Field Arrangements Based on Flattening Filter-Free Beams for Synchronous Bilateral Breast Carcinoma Radiation Therapy. Pract Radiat Oncol 2024; 14:e190-e202. [PMID: 37967748 DOI: 10.1016/j.prro.2023.11.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2023] [Revised: 10/14/2023] [Accepted: 11/05/2023] [Indexed: 11/17/2023]
Abstract
PURPOSE Flattening filter-free (FFF)-based volumetric modulated arc therapy (VMAT) has been shown to be feasible and significantly improves treatment efficiency and lung protection for synchronous bilateral breast irradiation (SBBI). This research compared the commonly used VMAT field arrangements using FFF beams. METHODS Twenty-eight patients underwent SBBI were retrospectively enrolled to design irradiation plans using tangential arc VMAT (taVMAT), half arc VMAT (haVMAT), and large arc VMAT (laVMAT). Dosimetric and delivery parameters of all designed plans were recorded and compared. RESULTS Comparable target volume coverage was observed for all field arrangements. taVMAT significantly reduced the dose to spinal cord and the volume covered by 5 Gy (V5Gy) and V7Gy of the lungs while decreasing the conformity index of the target volume. It also increased the volume covered by 105% of the prescription dose (V105%) and V107% of the target volume. haVMAT considerably decreased V20 Gy and V30 Gy of the lungs, mean dose (Dmean) and V30 Gy of the heart and the liver. It also notably reduced Dmean and V40 Gy of the left anterior descending coronary artery while increasing the beam-on time. laVMAT significantly reduced the mean treatment time (range, 113-117 seconds) compared with the other field arrangements. CONCLUSIONS There were distinct differences in various dosimetric and delivery parameters for different field arrangements, highlighting the importance of selecting the appropriate field arrangement based on specific treatment goals and considerations. This study contributes valuable insights into the use of FFF-based VMAT techniques in SBBI.
Collapse
Affiliation(s)
- Xingxing Zhang
- Guangdong Provincial Key Laboratory of Malignant Tumor Epigenetics and Gene Regulation, Medical Research Center, Sun Yat-Sen Memorial Hospital, Sun Yat-Sen University, Guangzhou, China; Department of Radiation Oncology, Sun Yat-Sen Memorial Hospital, Sun Yat-Sen University, Guangzhou, China
| | - Juntian Shi
- Guangdong Provincial Key Laboratory of Malignant Tumor Epigenetics and Gene Regulation, Medical Research Center, Sun Yat-Sen Memorial Hospital, Sun Yat-Sen University, Guangzhou, China; Department of Radiation Oncology, Sun Yat-Sen Memorial Hospital, Sun Yat-Sen University, Guangzhou, China
| | - Xiuxiu Wu
- Guangdong Provincial Key Laboratory of Malignant Tumor Epigenetics and Gene Regulation, Medical Research Center, Sun Yat-Sen Memorial Hospital, Sun Yat-Sen University, Guangzhou, China; Department of Radiation Oncology, Sun Yat-Sen Memorial Hospital, Sun Yat-Sen University, Guangzhou, China
| | - Liting Li
- Guangdong Provincial Key Laboratory of Malignant Tumor Epigenetics and Gene Regulation, Medical Research Center, Sun Yat-Sen Memorial Hospital, Sun Yat-Sen University, Guangzhou, China; Department of Radiation Oncology, Sun Yat-Sen Memorial Hospital, Sun Yat-Sen University, Guangzhou, China
| | - Wei Sun
- Guangdong Provincial Key Laboratory of Malignant Tumor Epigenetics and Gene Regulation, Medical Research Center, Sun Yat-Sen Memorial Hospital, Sun Yat-Sen University, Guangzhou, China; Department of Radiation Oncology, Sun Yat-Sen Memorial Hospital, Sun Yat-Sen University, Guangzhou, China
| | - Yongmei Zou
- Guangdong Provincial Key Laboratory of Malignant Tumor Epigenetics and Gene Regulation, Medical Research Center, Sun Yat-Sen Memorial Hospital, Sun Yat-Sen University, Guangzhou, China; Department of Radiation Oncology, Sun Yat-Sen Memorial Hospital, Sun Yat-Sen University, Guangzhou, China
| | - Guoquan Chen
- Guangdong Provincial Key Laboratory of Malignant Tumor Epigenetics and Gene Regulation, Medical Research Center, Sun Yat-Sen Memorial Hospital, Sun Yat-Sen University, Guangzhou, China; Department of Radiation Oncology, Sun Yat-Sen Memorial Hospital, Sun Yat-Sen University, Guangzhou, China
| | - Shaokun Wu
- Guangdong Provincial Key Laboratory of Malignant Tumor Epigenetics and Gene Regulation, Medical Research Center, Sun Yat-Sen Memorial Hospital, Sun Yat-Sen University, Guangzhou, China; Department of Radiation Oncology, Sun Yat-Sen Memorial Hospital, Sun Yat-Sen University, Guangzhou, China
| | - Song Duan
- Guangdong Provincial Key Laboratory of Malignant Tumor Epigenetics and Gene Regulation, Medical Research Center, Sun Yat-Sen Memorial Hospital, Sun Yat-Sen University, Guangzhou, China; Department of Radiation Oncology, Sun Yat-Sen Memorial Hospital, Sun Yat-Sen University, Guangzhou, China.
| |
Collapse
|
2
|
Kargar N, Zeinali A, Molazadeh M. Impact of Dose Calculation Algorithms and Radiobiological Parameters on Prediction of Cardiopulmonary Complications in Left Breast Radiation Therapy. J Biomed Phys Eng 2024; 14:129-140. [PMID: 38628897 PMCID: PMC11016826 DOI: 10.31661/jbpe.v0i0.2305-1616] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2023] [Accepted: 12/13/2023] [Indexed: 04/19/2024]
Abstract
Background Breast cancer requires evaluating treatment plans using dosimetric and biological parameters. Considering radiation dose distribution and tissue response, healthcare professionals can optimize treatment plans for better outcomes. Objective This study aimed to evaluate the effects of the different Dose Calculation Algorithms (DCAs) and Biologically Model-Related Parameters (BMRPs) on the prediction of cardiopulmonary complications due to left breast radiotherapy. Material and Methods In this practical study, the treatment plans of 21 female patients were simulated in the Monaco Treatment Planning System (TPS) with a prescribed dose of 50 Gy in 25 fractions. Dose distribution was extracted using the three DCAs [Pencil Beam (PB), Collapsed Cone (CC), and Monte Carlo (MC)]. Cardiopulmonary complications were predicted by Normal Tissue Complication Probability (NTCP) calculations using different dosimetric and biological parameters. The Lyman-Kutcher-Burman (LKB) and Relative-Seriality (RS) models were used to calculate NTCP. The endpoint for NTCP calculation was pneumonitis, pericarditis, and late cardiac mortality. The ANOVA test was used for statistical analysis. Results In calculating Tumor Control Probability (TCP), a statistically significant difference was observed between the results of DCAs in the Poisson model. The PB algorithm estimated NTCP as less than others for all Pneumonia BMRPs. Conclusion The impact of DCAs and BMRPs differs in the estimation of TCP and NTCP. DCAs have a stronger influence on TCP calculation, providing more effective results. On the other hand, BMRPs are more effective in estimating NTCP. Consequently, parameters for radiobiological indices should be cautiously used s to ensure the appropriate consideration of both DCAs and BMRPs.
Collapse
Affiliation(s)
- Niloofar Kargar
- Department of Medical Physics, Faculty of Medicine, Urmia University of Medical Sciences, Urmia, Iran
| | - Ahad Zeinali
- Department of Medical Physics, Faculty of Medicine, Urmia University of Medical Sciences, Urmia, Iran
| | - Mikaeil Molazadeh
- Department of Medical Physics, Faculty of Medicine, Tabriz University of Medical Sciences, Tabriz, Iran
| |
Collapse
|
3
|
Bonaccorsi SG, Tessonnier T, Hoeltgen L, Meixner E, Harrabi S, Hörner-Rieber J, Haberer T, Abdollahi A, Debus J, Mairani A. Exploring Helium Ions' Potential for Post-Mastectomy Left-Sided Breast Cancer Radiotherapy. Cancers (Basel) 2024; 16:410. [PMID: 38254899 PMCID: PMC10814201 DOI: 10.3390/cancers16020410] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2023] [Revised: 01/04/2024] [Accepted: 01/11/2024] [Indexed: 01/24/2024] Open
Abstract
Proton therapy presents a promising modality for treating left-sided breast cancer due to its unique dose distribution. Helium ions provide increased conformality thanks to a reduced lateral scattering. Consequently, the potential clinical benefit of both techniques was explored. An explorative treatment planning study involving ten patients, previously treated with VMAT (Volumetric Modulated Arc Therapy) for 50 Gy in 25 fractions for locally advanced, node-positive breast cancer, was carried out using proton pencil beam therapy with a fixed relative biological effectiveness (RBE) of 1.1 and helium therapy with a variable RBE described by the mMKM (modified microdosimetric kinetic model). Results indicated that target coverage was improved with particle therapy for both the clinical target volume and especially the internal mammary lymph nodes compared to VMAT. Median dose value analysis revealed that proton and helium plans provided lower dose on the left anterior descending artery (LAD), heart, lungs and right breast than VMAT. Notably, helium therapy exhibited improved ipsilateral lung sparing over protons. Employing NTCP models as available in the literature, helium therapy showed a lower probability of grade ≤ 2 radiation pneumonitis (22% for photons, 5% for protons and 2% for helium ions), while both proton and helium ions reduce the probability of major coronary events with respect to VMAT.
Collapse
Affiliation(s)
| | - Thomas Tessonnier
- Heidelberg Ion-Beam Therapy Center (HIT), Heidelberg University Hospital, 69120 Heidelberg, Germany
- Division of Molecular and Translational Radiation Oncology, National Center for Tumor Diseases (NCT), Heidelberg University Hospital, 69120 Heidelberg, Germany
| | - Line Hoeltgen
- Department of Radiation Oncology, Heidelberg University Hospital, 69120 Heidelberg, Germany
| | - Eva Meixner
- Department of Radiation Oncology, Heidelberg University Hospital, 69120 Heidelberg, Germany
| | - Semi Harrabi
- Department of Radiation Oncology, Heidelberg University Hospital, 69120 Heidelberg, Germany
| | - Juliane Hörner-Rieber
- Department of Radiation Oncology, Heidelberg University Hospital, 69120 Heidelberg, Germany
- Heidelberg Institute of Radiation Oncology (HIRO), German Cancer Research Center (DKFZ), 69120 Heidelberg, Germany
- Clinical Cooperation Unit Radiation Oncology, German Cancer Research Center (DKFZ), 69120 Heidelberg, Germany
| | - Thomas Haberer
- Heidelberg Ion-Beam Therapy Center (HIT), Heidelberg University Hospital, 69120 Heidelberg, Germany
| | - Amir Abdollahi
- Heidelberg Ion-Beam Therapy Center (HIT), Heidelberg University Hospital, 69120 Heidelberg, Germany
- Division of Molecular and Translational Radiation Oncology, National Center for Tumor Diseases (NCT), Heidelberg University Hospital, 69120 Heidelberg, Germany
- Heidelberg Institute of Radiation Oncology (HIRO), German Cancer Research Center (DKFZ), 69120 Heidelberg, Germany
- German Cancer Consortium (DKTK), 69120 Heidelberg, Germany
| | - Jürgen Debus
- Heidelberg Ion-Beam Therapy Center (HIT), Heidelberg University Hospital, 69120 Heidelberg, Germany
- Department of Radiation Oncology, Heidelberg University Hospital, 69120 Heidelberg, Germany
- Clinical Cooperation Unit Radiation Oncology, German Cancer Research Center (DKFZ), 69120 Heidelberg, Germany
- German Cancer Consortium (DKTK), 69120 Heidelberg, Germany
| | - Andrea Mairani
- Heidelberg Ion-Beam Therapy Center (HIT), Heidelberg University Hospital, 69120 Heidelberg, Germany
- Division of Molecular and Translational Radiation Oncology, National Center for Tumor Diseases (NCT), Heidelberg University Hospital, 69120 Heidelberg, Germany
- Centro Nazionale di Adroterapia Oncologica (CNAO), 27100 Pavia, Italy
| |
Collapse
|
4
|
Zhang Z, Li D, Peng F, Tan Z, Yang P, Peng Z, Li X, Qi X, Sun W, Liu Y, Wang Y. Evaluation of Hybrid VMAT Advantages and Robustness Considering Setup Errors Using Surface Guided Dose Accumulation for Internal Lymph Mammary Nodes Irradiation of Postmastectomy Radiotherapy. Front Oncol 2022; 12:907181. [PMID: 35936730 PMCID: PMC9354548 DOI: 10.3389/fonc.2022.907181] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2022] [Accepted: 06/20/2022] [Indexed: 11/14/2022] Open
Abstract
Objectives Setup error is a key factor affecting postmastectomy radiotherapy (PMRT) and irradiation of the internal mammary lymph nodes is the most investigated aspect for PMRT patients. In this study, we evaluated the robustness, radiobiological, and dosimetric benefits of the hybrid volumetric modulated arc therapy (H-VMAT) planning technique based on the setup error in dose accumulation using a surface-guided system for radiation therapy. Methods We retrospectively selected 32 patients treated by a radiation oncologist and evaluated the clinical target volume (CTV), including internal lymph node irradiation (IMNIs), and considered the planning target volume (PTV) margin to be 5 mm. Three different planning techniques were evaluated: tangential-VMAT (T-VMAT), intensity-modulated radiation therapy (IMRT), and H-VMAT. The interfraction and intrafraction setup errors were analyzed in each field and the accumulated dose was evaluated as the patients underwent daily surface-guided monitoring. These parameters were included while evaluating CTV coverage, the dose required for the left anterior descending artery (LAD) and the left ventricle (LV), the normal tissue complication probability (NTCP) for the heart and lungs, and the second cancer complication probability (SCCP) for contralateral breast (CB). Results When the setup error was accounted for dose accumulation, T-VMAT (95.51%) and H-VMAT (95.48%) had a higher CTV coverage than IMRT (91.25%). In the NTCP for the heart, H-VMAT (0.04%) was higher than T-VMAT (0.01%) and lower than IMRT (0.2%). However, the SCCP (1.05%) of CB using H-VMAT was lower than that using T-VMAT (2%) as well as delivery efficiency. And T-VMAT (3.72) and IMRT (10.5).had higher plan complexity than H-VMAT (3.71). Conclusions In this study, based on the dose accumulation of setup error for patients with left-sided PMRT with IMNI, we found that the H-VMAT technique was superior for achieving an optimum balance between target coverage, OAR dose, complication probability, plan robustness, and complexity.
Collapse
Affiliation(s)
- Zhe Zhang
- Department of Radiation Oncology, Peking University Shenzhen Hospital, Shenzhen, China
| | - Daming Li
- Department of Radiation Oncology, Peking University Shenzhen Hospital, Shenzhen, China
| | - Feng Peng
- Department of Radiation Oncology, Peking University Shenzhen Hospital, Shenzhen, China
| | - Zhibo Tan
- Department of Radiation Oncology, Peking University Shenzhen Hospital, Shenzhen, China
| | - Pengfei Yang
- Department of Radiation Oncology, Peking University Shenzhen Hospital, Shenzhen, China
| | - Zhaoming Peng
- Department of Radiation Oncology, Peking University Shenzhen Hospital, Shenzhen, China
| | - Xin Li
- Department of Radiation Oncology, Peking University Shenzhen Hospital, Shenzhen, China
- Hong Kong University of Science and Technology Medical Center, Shenzhen-Peking University, Shenzhen, China
| | - Xinyue Qi
- Department of Statistics and Data Science, Southern University of Science and Technology, Shenzhen, China
| | - Weixiao Sun
- Department of Statistics and Data Science, Southern University of Science and Technology, Shenzhen, China
| | - Yajie Liu
- Department of Radiation Oncology, Peking University Shenzhen Hospital, Shenzhen, China
- Hong Kong University of Science and Technology Medical Center, Shenzhen-Peking University, Shenzhen, China
- *Correspondence: Yajie Liu, ; Yuenan Wang,
| | - Yuenan Wang
- Department of Radiation Oncology, Peking University Shenzhen Hospital, Shenzhen, China
- Department of Statistics and Data Science, Southern University of Science and Technology, Shenzhen, China
- *Correspondence: Yajie Liu, ; Yuenan Wang,
| |
Collapse
|
5
|
Lai J, Zhong F, Deng J, Hu S, Shen R, Luo H, Luo Y. Prone position versus supine position in postoperative radiotherapy for breast cancer: A meta-analysis. Medicine (Baltimore) 2021; 100:e26000. [PMID: 34011096 PMCID: PMC8136988 DOI: 10.1097/md.0000000000026000] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/29/2020] [Accepted: 04/23/2021] [Indexed: 01/05/2023] Open
Abstract
BACKGROUND This meta-analysis evaluates the difference of sparing organs at risk (OAR) in different position (Prone position and Supine position) with different breathing patterns (Free breathing, FB/Deep inspiration breath hold, DIBH) for breast cancer patients receiving postoperative radiotherapy and provides a useful reference for clinical practice. METHOD The relevant controlled trials of prone position versus supine position in postoperative radiotherapy for breast cancer were retrieved from the sources of PubMed, Cochrane Library, Embase, Web of Science and ClinicalTrails.gov. The principal outcome of interest was OAR doses (heart dose, left anterior descending coronary artery dose and ipsilateral lung dose) and target coverage. We mainly compared the effects of P-FB (Prone position FB) and S-FB (Supine position FB) and discussed the effects of DIBH combined with different positions on OAR dose in postoperative radiotherapy. We calculated summary standardized mean difference (SMD) and 95% confidence intervals (CI). The meta-analysis was performed using RevMan 5.4 software. RESULTS The analysis included 751 patients from 19 observational studies. Compared with the S-FB, the P-FB can have lower heart dose, left anterior descending coronary artery (LADCA) dose, and ipsilateral lung dose (ILL) more effectively, and the difference was statistically significant (heart dose, SMD = - 0.51, 95% CI - 0.66 ∼ - 0.36, P < .00001. LADCA dose, SMD = - 0.58, 95% CI - 0.85 ∼ - 0.31, P < .0001. ILL dose, SMD = - 2.84, 95% CI - 3.2 ∼ - 2.48, P < .00001). And there was no significant difference in target coverage between the S-FB and P-FB groups (SMD = - 0.1, 95% CI - 0.57 ∼ 0.36, P = .66). Moreover, through descriptive analysis, we found that P-DIBH (Prone position DIBH) has better sparing OAR than P-FB and S-DIBH (Supine position DIBH). CONCLUSION By this meta-analysis, compared with the S-FB we found that implementation of P-FB in postoperative radiotherapy for breast cancer can reduce irradiation of heart dose, LADCA dose and ILL dose, without compromising mean dose of target coverage. Moreover, P-DIBH might become the most promising way for breast cancer patients to undergo radiotherapy.
Collapse
Affiliation(s)
- Junming Lai
- Department of Radiation Oncology, Yiwu Central Hospital, The Affiliated Yiwu Hospital of Wenzhou Medical University, Yiwu, Zhejiang
| | - Fangyan Zhong
- Department of oncology, The First Affiliated Hospital of Nanchang University, Nanchang University, Nanchang, Jiangxi
| | - Jianxiong Deng
- Department of oncology, The First Affiliated Hospital of Nanchang University, Nanchang University, Nanchang, Jiangxi
| | - Shuang Hu
- Department of General Medicine, Yiwu Central Hospital, The Affiliated Yiwu Hospital of Wenzhou Medical University, Yiwu, Zhejiang
| | - Ruoyan Shen
- Department of Second Institute of Clinical Medicine, Zhejiang Chinese Medical University, Hangzhou, Zhejiang, P.R. China
| | - Hui Luo
- Department of oncology, The First Affiliated Hospital of Nanchang University, Nanchang University, Nanchang, Jiangxi
| | - Yongbiao Luo
- Department of Radiation Oncology, Yiwu Central Hospital, The Affiliated Yiwu Hospital of Wenzhou Medical University, Yiwu, Zhejiang
| |
Collapse
|
6
|
Marteinsdottir M, Wang CC, McNamara A, Depauw N, Shin J, Paganetti H. The impact of variable relative biological effectiveness in proton therapy for left-sided breast cancer when estimating normal tissue complications in the heart and lung. Phys Med Biol 2021; 66:035023. [PMID: 33522498 DOI: 10.1088/1361-6560/abd230] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
The aim of this study was to evaluate the clinical impact of relative biological effectiveness (RBE) variations in proton beam scanning treatment (PBS) for left-sided breast cancer versus the assumption of a fixed RBE of 1.1, particularly in the context of comparisons with photon-based three-dimensional conformal radiotherapy (3DCRT) and volumetric modulated arc therapy (VMAT). Ten patients receiving radiation treatment to the whole breast/chest wall and regional lymph nodes were selected for each modality. For PBS, the dose distributions were re-calculated with both a fixed RBE and a variable RBE using an empirical RBE model. Dosimetric indices based on dose-volume histogram analysis were calculated for the entire heart wall, left anterior descending artery (LAD) and left lung. Furthermore, normal tissue toxicity probabilities for different endpoints were evaluated. The results show that applying a variable RBE significantly increases the RBE-weighted dose and consequently the calculated dosimetric indices increases for all organs compared to a fixed RBE. The mean dose to the heart and the maximum dose to the LAD and the left lung are significantly lower for PBS assuming a fixed RBE compared to 3DCRT. However, no statistically significant difference is seen when a variable RBE is applied. For a fixed RBE, lung toxicities are significantly lower compared to 3DCRT but when applying a variable RBE, no statistically significant differences are noted. A disadvantage is seen for VMAT over both PBS and 3DCRT. One-to-one plan comparison on 8 patients between PBS and 3DCRT shows similar results. We conclude that dosimetric analysis for all organs and toxicity estimation for the left lung might be underestimated when applying a fixed RBE for protons. Potential RBE variations should therefore be considered as uncertainty bands in outcome analysis.
Collapse
Affiliation(s)
- Maria Marteinsdottir
- Department of Radiation Oncology, Massachusetts General Hospital, Boston, MA 02114, United States of America. Faculty of Physical Sciences, University of Iceland, Dunhaga 5, IS-107 Reykjavik, Iceland
| | | | | | | | | | | |
Collapse
|
7
|
Fadavi P, Ahmadi HK, Diba AAY, Jafari F, Alamolhoda M. Dosimetric comparison of left sided whole breast irradiation with Tangential wedge beam, electron boosted Tangential wedged beam and asymmetric technique. J Family Med Prim Care 2020; 9:6135-6139. [PMID: 33681053 PMCID: PMC7928138 DOI: 10.4103/jfmpc.jfmpc_1476_20] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2020] [Revised: 09/15/2020] [Accepted: 11/03/2020] [Indexed: 11/05/2022] Open
Abstract
Background: Irradiation of the adjacent critical structures is inevitable in breast cancer radiotherapy (RT). Our purpose is to assess the dose distribution across the breast tissue and adjacent organs with our institutional asymmetric technique for left-sided breast cancer compared to the standard tangential wedged beam (TWB) and electron-boosted TWB techniques. Materials and Methods: The three RT planning were created for 30 consecutive patients with a focus on proper coverage of the planning target volume (PTV). The irritated doses into the heart, ipsilateral lung, and left anterior descending artery (LAD) were evaluated. Results: No significant difference was found in the mean values of relative PTV irradiated to 47.5 Gy, PTV dose and the volume of PTV, and critical organs between the treatments. The mean dose (Dmean) irradiated to the heart and LAD was lowest with the electron-boosted TWB. The Dmean to the heart was comparable between the TWB and asymmetric RT techniques, while the Dmean to LAD was significantly reduced with asymmetric technique versus TWB. The heart volume receiving ≥25 Gy and the Dmean to the left lung were significantly decreased with the asymmetric technique compared with TWB. The mean relative lung volume irradiated to ≥20 Gy was comparable between all techniques. The mean central lung distance was also significantly increased from 18.03 ± 4.5 cm with asymmetric RT to 37.47 ± 5.6 cm with TWB and to 27.67 ± 3.8 cm with electron-boosted TWB techniques. Conclusion: The asymmetric technique is useful for patients with breast cancer on the left side, having acceptable PTV coverage and considerably reduced cardiopulmonary doses.
Collapse
Affiliation(s)
- Pedram Fadavi
- Department of Radiation Oncology, Shohadaye 7 Tir Hospital, Iran University of Medical Sciences, Tehran, Iran
| | - Helaleh Khoshbakht Ahmadi
- Department of Radiation Oncology, Shohadaye 7 Tir Hospital, Iran University of Medical Sciences, Tehran, Iran
| | - Ali Asghar Yousefi Diba
- Department of Radiation Oncology, Shohadaye 7 Tir Hospital, Iran University of Medical Sciences, Tehran, Iran
| | - Fatemeh Jafari
- Radiation Oncology Research Center, Cancer Institute, Imam Khomeini Hospital, Tehran University of Medical Sciences, Tehran, Iran.,Department of Radiation Oncology, Cancer Institute, Imam Khomeini Hospital Complex, Tehran University of Medical Sciences, Tehran, Iran
| | - Mahboobeh Alamolhoda
- Department of Radiation Oncology, Shohadaye 7 Tir Hospital, Iran University of Medical Sciences, Tehran, Iran
| |
Collapse
|
8
|
Moiseenko V, Marks LB, Grimm J, Jackson A, Milano MT, Hattangadi-Gluth JA, Huynh-Le MP, Pettersson N, Yorke E, El Naqa I. A Primer on Dose-Response Data Modeling in Radiation Therapy. Int J Radiat Oncol Biol Phys 2020; 110:11-20. [PMID: 33358230 DOI: 10.1016/j.ijrobp.2020.11.020] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2020] [Revised: 11/05/2020] [Accepted: 11/05/2020] [Indexed: 12/11/2022]
Abstract
An overview of common approaches used to assess a dose response for radiation therapy-associated endpoints is presented, using lung toxicity data sets analyzed as a part of the High Dose per Fraction, Hypofractionated Treatment Effects in the Clinic effort as an example. Each component presented (eg, data-driven analysis, dose-response analysis, and calculating uncertainties on model prediction) is addressed using established approaches. Specifically, the maximum likelihood method was used to calculate best parameter values of the commonly used logistic model, the profile-likelihood to calculate confidence intervals on model parameters, and the likelihood ratio to determine whether the observed data fit is statistically significant. The bootstrap method was used to calculate confidence intervals for model predictions. Correlated behavior of model parameters and implication for interpreting dose response are discussed.
Collapse
Affiliation(s)
- Vitali Moiseenko
- Department of Radiation Medicine and Applied Sciences, University of California, San Diego, La Jolla, California.
| | - Lawrence B Marks
- Department of Radiation Oncology and the Lineberger Comprehensive Cancer Center, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina
| | - Jimm Grimm
- Department of Radiation Oncology, Geisinger Health System, Danville, Pennsylvania
| | - Andrew Jackson
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York
| | - Michael T Milano
- Department of Radiation Oncology, University of Rochester, Rochester, New York
| | - Jona A Hattangadi-Gluth
- Department of Radiation Medicine and Applied Sciences, University of California, San Diego, La Jolla, California
| | - Minh-Phuong Huynh-Le
- Department of Radiation Medicine and Applied Sciences, University of California, San Diego, La Jolla, California
| | - Niclas Pettersson
- Department of Radiation Physics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden; Department of Medical Physics and Biomedical Engineering, Sahlgrenska University Hospital, Gothenburg, Sweden
| | - Ellen Yorke
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York
| | - Issam El Naqa
- Department of Machine Learning, Moffitt Cancer Center, Tampa, Florida
| |
Collapse
|
9
|
Anzic M, Marinko T. Effect of Adjuvant Hormonal Therapy on the Development of Pulmonary Fibrosis after Postoperative Radiotherapy for Breast Cancer. J Breast Cancer 2020; 23:449-459. [PMID: 33154822 PMCID: PMC7604379 DOI: 10.4048/jbc.2020.23.e48] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2020] [Accepted: 08/19/2020] [Indexed: 12/15/2022] Open
Abstract
Breast cancer is the most common malignancy among women. Therefore, it is of paramount importance to study the adverse effects of oncological treatment of breast cancer, with one of adverse effects being pulmonary fibrosis (PF). PF is an irreversible condition and can significantly reduce the quality of life. Following lumpectomy, radiotherapy is the standard adjuvant treatment for breast cancer. Additionally, hormone receptor-positive breast cancers are treated with adjuvant hormonal therapy. While radiotherapy is one of the known causes of PF, the effect of hormone therapy on its development is not well-defined. Some studies have shown that the concomitant administration of endocrine therapy, primarily tamoxifen, and irradiation may potentiate the development of PF. However, guidelines regarding the timing of hormone therapy administration with respect to adjuvant radiotherapy are not clearly defined. This review aims to provide a comprehensive overview of the available information regarding the effect of hormone therapy and its timing of administration with respect to adjuvant radiotherapy on the incidence of PF.
Collapse
Affiliation(s)
- Mitja Anzic
- Division of Radiotherapy, Institute of Oncology, Ljubljana, Slovenia
| | - Tanja Marinko
- Division of Radiotherapy, Institute of Oncology, Ljubljana, Slovenia.,Faculty of Medicine, University of Ljubljana, Ljubljana, Slovenia
| |
Collapse
|
10
|
Saini AS, Das IJ, Hwang CS, Biagioli MC, Lee WE. Biological Indices Evaluation of Various Treatment Techniques for Left-Sided Breast Treatment. Pract Radiat Oncol 2019; 9:e579-e590. [DOI: 10.1016/j.prro.2019.06.020] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2019] [Revised: 06/20/2019] [Accepted: 06/28/2019] [Indexed: 10/26/2022]
|
11
|
Kügele M, Mannerberg A, Nørring Bekke S, Alkner S, Berg L, Mahmood F, Thornberg C, Edvardsson A, Bäck SÅJ, Behrens CF, Ceberg S. Surface guided radiotherapy (SGRT) improves breast cancer patient setup accuracy. J Appl Clin Med Phys 2019; 20:61-68. [PMID: 31478615 PMCID: PMC6753725 DOI: 10.1002/acm2.12700] [Citation(s) in RCA: 60] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2019] [Revised: 06/13/2019] [Accepted: 07/26/2019] [Indexed: 11/11/2022] Open
Abstract
PURPOSE The purpose of the study was to investigate if surface guided radiotherapy (SGRT) can decrease setup deviations for tangential and locoregional breast cancer patients compared to conventional laser-based setup (LBS). MATERIALS AND METHODS Both tangential (63 patients) and locoregional (76 patients) breast cancer patients were enrolled in this study. For LBS, the patients were positioned by aligning skin markers to the room lasers. For the surface based setup (SBS), an optical surface scanning system was used for daily setup using both single and three camera systems. To compare the two setup methods, the patient position was evaluated using verification imaging (field images or orthogonal images). RESULTS For both tangential and locoregional treatments, SBS decreased the setup deviation significantly compared to LBS (P < 0.01). For patients receiving tangential treatment, 95% of the treatment sessions were within the clinical tolerance of ≤ 4 mm in any direction (lateral, longitudinal or vertical) using SBS, compared to 84% for LBS. Corresponding values for patients receiving locoregional treatment were 70% and 54% for SBS and LBS, respectively. No significant difference was observed comparing the setup result using a single camera system or a three camera system. CONCLUSIONS Conventional laser-based setup can with advantage be replaced by surface based setup. Daily SGRT improves patient setup without additional imaging dose to breast cancer patients regardless if a single or three camera system was used.
Collapse
Affiliation(s)
- Malin Kügele
- Department of Hematology, Oncology and Radiation Physics, Skåne University Hospital, Lund, Sweden.,Medical Radiation Physics, Department of Clinical Sciences, Lund University, Lund, Sweden
| | - Annika Mannerberg
- Medical Radiation Physics, Department of Clinical Sciences, Lund University, Lund, Sweden
| | - Susanne Nørring Bekke
- Radiotherapy Research Unit, Department of Oncology, Herlev Hospital, University of Copenhagen, Copenhagen, Denmark
| | - Sara Alkner
- Department of Hematology, Oncology and Radiation Physics, Skåne University Hospital, Lund, Sweden.,Department of Clinical Sciences, Division of Oncology and Pathology, Lund University, Lund, Sweden
| | - Lovisa Berg
- Department of Hematology, Oncology and Radiation Physics, Skåne University Hospital, Lund, Sweden
| | - Faisal Mahmood
- Department of Oncology, Odense University Hospital, Odense C, Denmark
| | - Charlotte Thornberg
- Department of Hematology, Oncology and Radiation Physics, Skåne University Hospital, Lund, Sweden
| | - Anneli Edvardsson
- Department of Hematology, Oncology and Radiation Physics, Skåne University Hospital, Lund, Sweden
| | - Sven Å J Bäck
- Department of Hematology, Oncology and Radiation Physics, Skåne University Hospital, Lund, Sweden
| | - Claus F Behrens
- Radiotherapy Research Unit, Department of Oncology, Herlev Hospital, University of Copenhagen, Copenhagen, Denmark
| | - Sofie Ceberg
- Department of Hematology, Oncology and Radiation Physics, Skåne University Hospital, Lund, Sweden.,Medical Radiation Physics, Department of Clinical Sciences, Lund University, Lund, Sweden
| |
Collapse
|
12
|
Palma G, Monti S, Conson M, Pacelli R, Cella L. Normal tissue complication probability (NTCP) models for modern radiation therapy. Semin Oncol 2019; 46:210-218. [PMID: 31506196 DOI: 10.1053/j.seminoncol.2019.07.006] [Citation(s) in RCA: 44] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/24/2019] [Accepted: 07/31/2019] [Indexed: 02/07/2023]
Abstract
Mathematical models of normal tissue complication probability (NTCP) able to robustly predict radiation-induced morbidities (RIM) play an essential role in the identification of a personalized optimal plan, and represent the key to maximizing the benefits of technological advances in radiation therapy (RT). Most modern RT techniques pose, however, new challenges in estimating the risk of RIM. The aim of this report is to schematically review NTCP models in the framework of advanced radiation therapy techniques. Issues relevant to hypofractionated stereotactic body RT and ion beam therapy are critically reviewed. Reirradiation scenarios for new or recurrent malignances and NTCP are also illustrated. A new phenomenological approach to predict RIM is suggested.
Collapse
Affiliation(s)
- Giuseppe Palma
- National Research Council, Institute of Biostructures and Bioimaging, Napoli, Italy
| | - Serena Monti
- National Research Council, Institute of Biostructures and Bioimaging, Napoli, Italy
| | - Manuel Conson
- Department of Advanced Biomedical Sciences, Federico II University School of Medicine, Naples, Italy
| | - Roberto Pacelli
- Department of Advanced Biomedical Sciences, Federico II University School of Medicine, Naples, Italy
| | - Laura Cella
- National Research Council, Institute of Biostructures and Bioimaging, Napoli, Italy.
| |
Collapse
|
13
|
Kaneko A, Sumida I, Mizuno H, Isohashi F, Suzuki O, Seo Y, Otani K, Tamari K, Ogawa K. Comparison of gamma index based on dosimetric error and clinically relevant dose-volume index based on three-dimensional dose prediction in breast intensity-modulated radiation therapy. Radiat Oncol 2019; 14:36. [PMID: 30808377 PMCID: PMC6390354 DOI: 10.1186/s13014-019-1233-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2018] [Accepted: 01/27/2019] [Indexed: 12/04/2022] Open
Abstract
Background Measurement-guided dose reconstruction has lately attracted significant attention because it can predict the delivered patient dose distribution. Although the treatment planning system (TPS) uses sophisticated algorithm to calculate the dose distribution, the calculation accuracy depends on the particular TPS used. This study aimed to investigate the relationship between the gamma passing rate (GPR) and the clinically relevant dose–volume index based on the predicted 3D patient dose distribution derived from two TPSs (XiO, RayStation). Methods Twenty-one breast intensity-modulated radiation therapy plans were inversely optimized using XiO. With the same plans, both TPSs calculated the planned dose distribution. We conducted per-beam measurements on the coronal plane using a 2D array detector and analyzed the difference in 2D GPRs between the measured and planned doses by commercial software. Using in-house software, we calculated the predicted 3D patient dose distribution and derived the predicted 3D GPR, the predicted per-organ 3D GPR, and the predicted clinically relevant dose–volume indices [dose–volume histogram metrics and the value of the tumor-control probability/normal tissue complication probability of the planning target volume and organs at risk]. The results derived from XiO were compared with those from RayStation. Results While the mean 2D GPRs derived from both TPSs were 98.1% (XiO) and 100% (RayStation), the mean predicted 3D GPRs of ipsilateral lung (73.3% [XiO] and 85.9% [RayStation]; p < 0.001) had no correlation with 2D GPRs under the 3% global/3 mm criterion. Besides, this significant difference in terms of referenced TPS between XiO and RayStation could be explained by the fact that the error of predicted V5Gy of ipsilateral lung derived from XiO (29.6%) was significantly larger than that derived from RayStation (− 0.2%; p < 0.001). Conclusions GPR is useful as a patient quality assurance to detect dosimetric errors; however, it does not necessarily contain detailed information on errors. Using the predicted clinically relevant dose–volume indices, the clinical interpretation of dosimetric errors can be obtained. We conclude that a clinically relevant dose–volume index based on the predicted 3D patient dose distribution could add to the clinical and biological considerations in the GPR, if we can guarantee the dose calculation accuracy of referenced TPS.
Collapse
Affiliation(s)
- Akari Kaneko
- Department of Radiation Oncology, Osaka University Graduate School of Medicine, 2-2 Yamada-oka, Suita, 565-0871, Osaka, Japan. .,Department of Radiology, Suita Tokushukai Hospital, 21-1 Senrioka-nishi, Suita, 565-0814, Osaka, Japan.
| | - Iori Sumida
- Department of Radiation Oncology, Osaka University Graduate School of Medicine, 2-2 Yamada-oka, Suita, 565-0871, Osaka, Japan
| | - Hirokazu Mizuno
- Department of Radiation Oncology, Osaka University Graduate School of Medicine, 2-2 Yamada-oka, Suita, 565-0871, Osaka, Japan
| | - Fumiaki Isohashi
- Department of Radiation Oncology, Osaka University Graduate School of Medicine, 2-2 Yamada-oka, Suita, 565-0871, Osaka, Japan
| | - Osamu Suzuki
- Department of Radiation Oncology, Osaka University Graduate School of Medicine, 2-2 Yamada-oka, Suita, 565-0871, Osaka, Japan
| | - Yuji Seo
- Department of Radiation Oncology, Osaka University Graduate School of Medicine, 2-2 Yamada-oka, Suita, 565-0871, Osaka, Japan
| | - Keisuke Otani
- Department of Radiation Oncology, Osaka University Graduate School of Medicine, 2-2 Yamada-oka, Suita, 565-0871, Osaka, Japan
| | - Keisuke Tamari
- Department of Radiation Oncology, Osaka University Graduate School of Medicine, 2-2 Yamada-oka, Suita, 565-0871, Osaka, Japan
| | - Kazuhiko Ogawa
- Department of Radiation Oncology, Osaka University Graduate School of Medicine, 2-2 Yamada-oka, Suita, 565-0871, Osaka, Japan
| |
Collapse
|
14
|
Rubinstein AE, Gay S, Peterson CB, Kingsley CV, Tailor RC, Pollard-Larkin JM, Melancon AD, Followill DS, Court LE. Radiation-induced lung toxicity in mice irradiated in a strong magnetic field. PLoS One 2018; 13:e0205803. [PMID: 30444887 PMCID: PMC6239291 DOI: 10.1371/journal.pone.0205803] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2018] [Accepted: 10/02/2018] [Indexed: 11/19/2022] Open
Abstract
Strong magnetic fields affect radiation dose deposition in MRI-guided radiation therapy systems, particularly at interfaces between tissues of differing densities such as those in the thorax. In this study, we evaluated the impact of a 1.5 T magnetic field on radiation-induced lung damage in C57L/J mice. We irradiated 140 mice to the whole thorax with parallel-opposed Co-60 beams to doses of 0, 9.0, 10.0, 10.5, 11.0, 12.0, or 13.0 Gy (20 mice per dose group). Ten mice per dose group were irradiated while a 1.5 T magnetic field was applied transverse to the radiation beam and ten mice were irradiated with the magnetic field set to 0 T. We compared survival and noninvasive assays of radiation-induced lung damage, namely respiratory rate and metrics derived from thoracic cone-beam CTs, between the two sets of mice. We report two main results. First, the presence of a transverse 1.5 T field during irradiation had no impact on survival of C57L/J mice. Second, there was a small but statistically significant effect on noninvasive assays of radiation-induced lung damage. These results provide critical safety data for the clinical introduction of MRI-guided radiation therapy systems.
Collapse
Affiliation(s)
- Ashley E. Rubinstein
- Department of Diagnostic and Interventional Imaging, UTHealth McGovern Medical School, Houston, Texas, United States of America
| | - Skylar Gay
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, United States of America
| | - Christine B. Peterson
- Department of Biostatistics, The University of Texas MD Anderson Cancer Center, Houston, Texas, United States of America
| | - Charles V. Kingsley
- Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, United States of America
| | - Ramesh C. Tailor
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, United States of America
| | - Julianne M. Pollard-Larkin
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, United States of America
| | - Adam D. Melancon
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, United States of America
| | - David S. Followill
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, United States of America
| | - Laurence E. Court
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, United States of America
- Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, United States of America
- * E-mail:
| |
Collapse
|
15
|
Menoux I, Le Fèvre C, Noël G, Antoni D. [Radiation-induced lung toxicity predictors after stereotactic radiation therapy for non-small cell lung carcinoma stage I]. Cancer Radiother 2018; 22:826-838. [PMID: 30337050 DOI: 10.1016/j.canrad.2017.12.007] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2017] [Revised: 11/08/2017] [Accepted: 12/22/2017] [Indexed: 12/19/2022]
Abstract
In case of refusal or contraindication for surgical management of a stage I non-small cell lung carcinoma, the validated alternative therapy is stereotactic irradiation. This technique reaches an equivalent tumour control rate than surgery and significantly higher than conventional radiotherapy. One of the dreaded complications is radiation induced lung toxicity (radiation pneumonitis and lung fibrosis), especially when it is symptomatic, occurring in about 10 % of cases. This article is a literature review of this complication's predictive factors.
Collapse
Affiliation(s)
- I Menoux
- Département universitaire de radiothérapie, centre Paul-Strauss, 3, rue de la Porte-de-l'Hôpital, BP 42, 67065 Strasbourg cedex, France.
| | - C Le Fèvre
- Département universitaire de radiothérapie, centre Paul-Strauss, 3, rue de la Porte-de-l'Hôpital, BP 42, 67065 Strasbourg cedex, France
| | - G Noël
- Département universitaire de radiothérapie, centre Paul-Strauss, 3, rue de la Porte-de-l'Hôpital, BP 42, 67065 Strasbourg cedex, France; EA 3430, laboratoire de radiobiologie, université de Strasbourg, fédération de médecine translationnelle de Strasbourg (FMTS), 67065 Strasbourg, France
| | - D Antoni
- Département universitaire de radiothérapie, centre Paul-Strauss, 3, rue de la Porte-de-l'Hôpital, BP 42, 67065 Strasbourg cedex, France; EA 3430, laboratoire de radiobiologie, université de Strasbourg, fédération de médecine translationnelle de Strasbourg (FMTS), 67065 Strasbourg, France
| |
Collapse
|
16
|
Westley T, Syrowatka A, Henault D, Rho YS, Khazoom F, Chang SL, Tamblyn R, Mayo N, Meguerditchian AN. Patterns and predictors of emergency department visits among older patients after breast cancer surgery: A population-based cohort study. J Geriatr Oncol 2018; 9:204-213. [DOI: 10.1016/j.jgo.2017.10.003] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2016] [Revised: 09/04/2017] [Accepted: 10/27/2017] [Indexed: 12/29/2022]
|
17
|
Dosimetric factors and Lyman normal-tissue complication modelling analysis for predicting radiation-induced lung injury in postoperative breast cancer radiotherapy: a prospective study. Oncotarget 2018; 8:33855-33863. [PMID: 27806340 PMCID: PMC5464917 DOI: 10.18632/oncotarget.12979] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2016] [Accepted: 10/24/2016] [Indexed: 01/23/2023] Open
Abstract
To investigate the relationship between dosimetric factors, including Lyman normal-tissue complication (NTCP) parameters and radiation-induced lung injury (RILI), in postoperative breast cancer patients treated by intensity modulated radiotherapy (IMRT). 109 breast cancer patients who received IMRT between January 2012 and December 2013 were prospectively enrolled. A maximum likelihood analysis yielded the best estimates for Lyman NTCP parameters. Ten patients were diagnosed with RILI (primarily Grade 1 or Grade 2 RILI); the rate of RILI was 9.17% (10/109). Multivariate analysis demonstrated that ipsilateral lung V20 was an independent predictor (P=0.001) of RILI. Setting V20=29.03% as the cut-off value, the prediction of RILI achieved high accuracy (94.5%), with a sensitivity of 80% and specificity of 96%. The NTCP model parameters for 109 patients were m=0.437, n=0.912, and TD50(1)=17.211 Gy. The sensitivity of the modified Lyman NTCP model to predict the RILI was 90% (9/10), the specificity was 69.7% (69/99), and the accuracy was 71.6% (78/109). The RILI rate of the NTCP<9.62% in breast cancer patients was 1.43% (1/70), but the RILI rate of the NTCP>9.62% in patients with breast cancer was 23.08% (9/39), (P=0.001). In conclusion, V20 is an independent predictive factor for RILI in patients with breast cancer treated by IMRT; V20=29.03% could be a useful dosimetric parameter to predict the risk of RILI. The Lyman NTCP model parameters of the new value (m=0.437, n=0.912, TD50 (1) =17.211 Gy) can be used as an effective biological index to evaluate the risk of RILI.
Collapse
|
18
|
Shirato H, Le QT, Kobashi K, Prayongrat A, Takao S, Shimizu S, Giaccia A, Xing L, Umegaki K. Selection of external beam radiotherapy approaches for precise and accurate cancer treatment. JOURNAL OF RADIATION RESEARCH 2018; 59:i2-i10. [PMID: 29373709 PMCID: PMC5868193 DOI: 10.1093/jrr/rrx092] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/21/2017] [Indexed: 05/05/2023]
Abstract
Physically precise external-beam radiotherapy (EBRT) technologies may not translate to the best outcome in individual patients. On the other hand, clinical considerations alone are often insufficient to guide the selection of a specific EBRT approach in patients. We examine the ways in which to compare different EBRT approaches based on physical, biological and clinical considerations, and how they can be enhanced with the addition of biophysical models and machine-learning strategies. The process of selecting an EBRT modality is expected to improve in tandem with knowledge-based treatment planning.
Collapse
Affiliation(s)
- Hiroki Shirato
- Department of Radiation Medicine, Faculty of Medicine, Hokkaido University, North-15 West-7, Kita-ku, 0608638, Sapporo, Hokkaido, Japan
- Global Station for Quantum Medical Science and Engineering, Global Institute for Cooperative Research and Education, Hokkaido University, North-15 West-7, Kita-ku, 0608638, Sapporo, Hokkaido, Japan
- Corresponding author. Department of Radiation Medicine, Faculty of Medicine, Hokkaido University, North-15 West-7, Kita-ku, 0608638, Sapporo, Hokkaido, Japan. Tel: +81-11-706-5977; Fax: +81-11-706-7876;
| | - Quynh-Thu Le
- Global Station for Quantum Medical Science and Engineering, Global Institute for Cooperative Research and Education, Hokkaido University, North-15 West-7, Kita-ku, 0608638, Sapporo, Hokkaido, Japan
- Department of Radiation Oncology, Stanford University School of Medicine, Stanford, CA, USA
| | - Keiji Kobashi
- Department of Medical Physics, Hokkaido University Hospital, Sapporo, Japan
| | - Anussara Prayongrat
- Department of Radiation Medicine, Faculty of Medicine, Hokkaido University, North-15 West-7, Kita-ku, 0608638, Sapporo, Hokkaido, Japan
| | - Seishin Takao
- Global Station for Quantum Medical Science and Engineering, Global Institute for Cooperative Research and Education, Hokkaido University, North-15 West-7, Kita-ku, 0608638, Sapporo, Hokkaido, Japan
- Department of Medical Physics, Hokkaido University Hospital, Sapporo, Japan
| | - Shinichi Shimizu
- Department of Radiation Medicine, Faculty of Medicine, Hokkaido University, North-15 West-7, Kita-ku, 0608638, Sapporo, Hokkaido, Japan
- Global Station for Quantum Medical Science and Engineering, Global Institute for Cooperative Research and Education, Hokkaido University, North-15 West-7, Kita-ku, 0608638, Sapporo, Hokkaido, Japan
| | - Amato Giaccia
- Global Station for Quantum Medical Science and Engineering, Global Institute for Cooperative Research and Education, Hokkaido University, North-15 West-7, Kita-ku, 0608638, Sapporo, Hokkaido, Japan
- Department of Radiation Oncology, Stanford University School of Medicine, Stanford, CA, USA
| | - Lei Xing
- Global Station for Quantum Medical Science and Engineering, Global Institute for Cooperative Research and Education, Hokkaido University, North-15 West-7, Kita-ku, 0608638, Sapporo, Hokkaido, Japan
- Department of Radiation Oncology, Stanford University School of Medicine, Stanford, CA, USA
| | - Kikuo Umegaki
- Global Station for Quantum Medical Science and Engineering, Global Institute for Cooperative Research and Education, Hokkaido University, North-15 West-7, Kita-ku, 0608638, Sapporo, Hokkaido, Japan
- Department of Medical Physics, Hokkaido University Hospital, Sapporo, Japan
| |
Collapse
|
19
|
Eyadeh MM, Weston MA, Juhasz J, Diamond KR. Translucent poly(vinyl alcohol) cryogel dosimeters for simultaneous dose buildup and monitoring during chest wall radiation therapy. J Appl Clin Med Phys 2016; 17:308-319. [PMID: 27685110 PMCID: PMC5874105 DOI: 10.1120/jacmp.v17i5.6148] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2015] [Revised: 06/09/2016] [Accepted: 05/31/2016] [Indexed: 11/23/2022] Open
Abstract
Chest wall radiation therapy treatment delivery was monitored using a 5 mm thick radiochromic poly(vinyl alcohol) cryogel that also provided buildup material. The cryogels were used to detect positioning errors and measure the impact of shifts for a chest wall treatment that was delivered to a RANDO phantom. The phantom was shifted by ± 2, ± 3, and ± 5 mm from the planned position in the anterior/posterior (A/P) direction; these shifts represent setup errors and the uncertainty associated with lung filling during breath-hold. The two-dimensional absolute dose distributions measured in the cryogel at the planned position were compared with the distributions at all shifts from this position using gamma analysis (3%/3 mm, 10% threshold). For shifts of ± 2, ± 3, and ± 5 mm the passing rates ranged from 94.3% to 95.6%, 74.0% to 78.8%, and 17.5% to 22.5%, respectively. These results are consistent with the same gamma analysis performed on dose planes calculated in the middle of the cryogel and on the phantom surface using our treatment plan-ning system, which ranged from 94.3% to 95.0%, 76.8% to 77.9%, and 23.5% to 24.3%, respectively. The Pinnacle dose planes were then scaled empirically and compared to the cryogel measurements. Using the same gamma metric, the pass rates ranged from 97.0% to 98.4%. The results of this study suggest that cryogels may be used as both a buildup material and to evaluate errors in chest wall treat-ment positioning during deep-inspiration breath-hold delivery. The cryogels are sensitive to A/P chest wall shifts of less than 3 mm, which potentially allows for the detection of clinically relevant errors.
Collapse
|
20
|
Coates J, Souhami L, El Naqa I. Big Data Analytics for Prostate Radiotherapy. Front Oncol 2016; 6:149. [PMID: 27379211 PMCID: PMC4905980 DOI: 10.3389/fonc.2016.00149] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2016] [Accepted: 05/31/2016] [Indexed: 12/14/2022] Open
Abstract
Radiation therapy is a first-line treatment option for localized prostate cancer and radiation-induced normal tissue damage are often the main limiting factor for modern radiotherapy regimens. Conversely, under-dosing of target volumes in an attempt to spare adjacent healthy tissues limits the likelihood of achieving local, long-term control. Thus, the ability to generate personalized data-driven risk profiles for radiotherapy outcomes would provide valuable prognostic information to help guide both clinicians and patients alike. Big data applied to radiation oncology promises to deliver better understanding of outcomes by harvesting and integrating heterogeneous data types, including patient-specific clinical parameters, treatment-related dose-volume metrics, and biological risk factors. When taken together, such variables make up the basis for a multi-dimensional space (the "RadoncSpace") in which the presented modeling techniques search in order to identify significant predictors. Herein, we review outcome modeling and big data-mining techniques for both tumor control and radiotherapy-induced normal tissue effects. We apply many of the presented modeling approaches onto a cohort of hypofractionated prostate cancer patients taking into account different data types and a large heterogeneous mix of physical and biological parameters. Cross-validation techniques are also reviewed for the refinement of the proposed framework architecture and checking individual model performance. We conclude by considering advanced modeling techniques that borrow concepts from big data analytics, such as machine learning and artificial intelligence, before discussing the potential future impact of systems radiobiology approaches.
Collapse
Affiliation(s)
- James Coates
- Department of Oncology, University of Oxford, Oxford, UK
| | - Luis Souhami
- Division of Radiation Oncology, McGill University Health Centre, Montreal, QC, Canada
| | - Issam El Naqa
- Department of Radiation Oncology, University of Michigan, Ann Arbor, MI, USA
| |
Collapse
|
21
|
Coates J, El Naqa I. Outcome modeling techniques for prostate cancer radiotherapy: Data, models, and validation. Phys Med 2016; 32:512-20. [PMID: 27053448 DOI: 10.1016/j.ejmp.2016.02.014] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/19/2015] [Revised: 01/25/2016] [Accepted: 02/13/2016] [Indexed: 12/25/2022] Open
Abstract
Prostate cancer is a frequently diagnosed malignancy worldwide and radiation therapy is a first-line approach in treating localized as well as locally advanced cases. The limiting factor in modern radiotherapy regimens is dose to normal structures, an excess of which can lead to aberrant radiation-induced toxicities. Conversely, dose reduction to spare adjacent normal structures risks underdosing target volumes and compromising local control. As a result, efforts aimed at predicting the effects of radiotherapy could invaluably optimize patient treatments by mitigating such toxicities and simultaneously maximizing biochemical control. In this work, we review the types of data, frameworks and techniques used for prostate radiotherapy outcome modeling. Consideration is given to clinical and dose-volume metrics, such as those amassed by the QUANTEC initiative, and also to newer methods for the integration of biological and genetic factors to improve prediction performance. We furthermore highlight trends in machine learning that may help to elucidate the complex pathophysiological mechanisms of tumor control and radiation-induced normal tissue side effects.
Collapse
Affiliation(s)
- James Coates
- Department of Oncology, University of Oxford, Oxford, UK
| | - Issam El Naqa
- Department of Radiation Oncology, University of Michigan, Ann Arbor, USA.
| |
Collapse
|
22
|
Meattini I, Guenzi M, Fozza A, Vidali C, Rovea P, Meacci F, Livi L. Overview on cardiac, pulmonary and cutaneous toxicity in patients treated with adjuvant radiotherapy for breast cancer. Breast Cancer 2016; 24:52-62. [DOI: 10.1007/s12282-016-0694-3] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2016] [Accepted: 03/20/2016] [Indexed: 12/25/2022]
|
23
|
Toltz A, Shin N, Mitrou E, Laude C, Freeman CR, Seuntjens J, Parker W, Roberge D. Late radiation toxicity in Hodgkin lymphoma patients: proton therapy's potential. J Appl Clin Med Phys 2015; 16:167–178. [PMID: 26699298 PMCID: PMC5690189 DOI: 10.1120/jacmp.v16i5.5386] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2014] [Revised: 05/20/2015] [Accepted: 05/03/2015] [Indexed: 12/22/2022] Open
Abstract
In 2010, all young patients treated for intrathoracic Hodgkin lymphoma (HL) at one of 10 radiotherapy centers in the province of Quebec received 3D conformal photon therapy. These patients may now be at risk for late effects of their treatment, notably secondary malignancies and cardiac toxicity. We hypothesized that more complex radiotherapy, including intensity‐modulated proton therapy (IMPT) and possibly IMRT (in the form of helical tomotherapy (HT)), could benefit these patients. With institutional review board approval at 10 institutions, all treatment plans for patients under the age of 30 treated for HL during a six‐month consecutive period of 2010 were retrieved. Twenty‐six patients were identified, and after excluding patients with extrathoracic radiation or treatment of recurrence, 20 patients were replanned for HT and IMPT. Neutron dose for IMPT plans was estimated from published measurements. The relative seriality model was used to predict excess risk of cardiac mortality. A modified linear quadratic model was used to predict the excess absolute risk for induction of lung cancer and, in female patients, breast cancer. Model parameters were derived from published data. Predicted risk for cardiac mortality was similar among the three treatment techniques (absolute excess risk of cardiac mortality was not reduced for HT or IMPT (p>0.05,p>0.05) as compared to 3D CRT). Predicted risks were increased for HT and reduced for IMPT for secondary lung cancer (p<0.001,p<0.001) and breast cancers (p<0.001,p<0.001) as compared to 3D CRT. PACS numbers: 87.55.dh, 87.55.dk
Collapse
|
24
|
Lee TF, Chao PJ, Chang L, Ting HM, Huang YJ. Developing Multivariable Normal Tissue Complication Probability Model to Predict the Incidence of Symptomatic Radiation Pneumonitis among Breast Cancer Patients. PLoS One 2015; 10:e0131736. [PMID: 26147496 PMCID: PMC4492617 DOI: 10.1371/journal.pone.0131736] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2015] [Accepted: 06/04/2015] [Indexed: 11/20/2022] Open
Abstract
Purpose Symptomatic radiation pneumonitis (SRP), which decreases quality of life (QoL), is the most common pulmonary complication in patients receiving breast irradiation. If it occurs, acute SRP usually develops 4–12 weeks after completion of radiotherapy and presents as a dry cough, dyspnea and low-grade fever. If the incidence of SRP is reduced, not only the QoL but also the compliance of breast cancer patients may be improved. Therefore, we investigated the incidence SRP in breast cancer patients after hybrid intensity modulated radiotherapy (IMRT) to find the risk factors, which may have important effects on the risk of radiation-induced complications. Methods In total, 93 patients with breast cancer were evaluated. The final endpoint for acute SRP was defined as those who had density changes together with symptoms, as measured using computed tomography. The risk factors for a multivariate normal tissue complication probability model of SRP were determined using the least absolute shrinkage and selection operator (LASSO) technique. Results Five risk factors were selected using LASSO: the percentage of the ipsilateral lung volume that received more than 20-Gy (IV20), energy, age, body mass index (BMI) and T stage. Positive associations were demonstrated among the incidence of SRP, IV20, and patient age. Energy, BMI and T stage showed a negative association with the incidence of SRP. Our analyses indicate that the risk of SPR following hybrid IMRT in elderly or low-BMI breast cancer patients is increased once the percentage of the ipsilateral lung volume receiving more than 20-Gy is controlled below a limitation. Conclusions We suggest to define a dose-volume percentage constraint of IV20< 37% (or AIV20< 310cc) for the irradiated ipsilateral lung in radiation therapy treatment planning to maintain the incidence of SPR below 20%, and pay attention to the sequelae especially in elderly or low-BMI breast cancer patients. (AIV20: the absolute ipsilateral lung volume that received more than 20 Gy (cc).
Collapse
Affiliation(s)
- Tsair-Fwu Lee
- Medical Physics and Informatics Laboratory of Electronics Engineering, National Kaohsiung University of Applied Sciences, Kaohsiung 80778, Taiwan, ROC
- Graduate Institute of Clinical Medicine, Kaohsiung Medical University, Kaohsiung 807, Taiwan, ROC
| | - Pei-Ju Chao
- Medical Physics and Informatics Laboratory of Electronics Engineering, National Kaohsiung University of Applied Sciences, Kaohsiung 80778, Taiwan, ROC
- Department of Radiation Oncology, Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Kaohsiung, 83305, Taiwan, ROC
| | - Liyun Chang
- Department of Medical Imaging and Radiological Sciences, I-Shou University, Kaohsiung 82445, Taiwan, ROC
| | - Hui-Min Ting
- Medical Physics and Informatics Laboratory of Electronics Engineering, National Kaohsiung University of Applied Sciences, Kaohsiung 80778, Taiwan, ROC
- Department of Radiation Oncology, Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Kaohsiung, 83305, Taiwan, ROC
| | - Yu-Jie Huang
- Department of Radiation Oncology, Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Kaohsiung, 83305, Taiwan, ROC
- * E-mail:
| |
Collapse
|
25
|
Jeba J, Isiah R, Subhashini J, Backianathan S, Thangakunam B, Christopher DJ. Radiation Pneumonitis After Conventional Radiotherapy For Breast Cancer: A Prospective Study. J Clin Diagn Res 2015; 9:XC01-XC05. [PMID: 26393189 PMCID: PMC4573021 DOI: 10.7860/jcdr/2015/13969.6211] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2015] [Accepted: 06/20/2015] [Indexed: 11/24/2022]
Abstract
BACKGROUND Loco-regional radiotherapy is an important treatment modality in breast cancer and radiation pneumonitis (RP) is one of the early toxicities. AIM To study the occurrence, correlation of RP with patient and radiotherapy related factors and the effects on pulmonary function following conventional radiotherapy in breast cancer. SETTINGS AND DESIGN Prospective study, from a tertiary hospital in a developing country. MATERIALS AND METHODS Prospective analysis of clinical symptoms, pulmonary function and radiologic changes was done prior to and 12 weeks after adjuvant radiotherapy (n=46). Statistical analysis was done using SPSS version 10 software. RESULTS Radiological and clinical RP was seen in 45.65% (n=21) and 19.56% (n=9) respectively. RP was significantly higher with age >50 years (OR 4.4), chest wall irradiation with electrons, (electrons 83.3% vs cobalt60 32.4%, p=0.02) and supraclavicular field treatment with 6 MV photons (p= 0.011). There was significant relationship between Inferior Lung Distance (ILD) and RP (p=0.013). The fall in Total Lung Capacity (TLC) was significantly more in those with RP (p=0.02). CONCLUSION Clinical RP occurs in almost one-fifth of breast cancer patients treated with conventional radiotherapy. Chest wall irradiation with electrons, supraclavicular field irradiation with 6 MV photons, higher ILD and age >50 years was associated with increased RP. The pulmonary function parameter most affected was TLC. The factors associated with increased RP should be considered when adjuvant radiotherapy is planned to minimize its likelihood and intervene appropriately.
Collapse
Affiliation(s)
- Jenifer Jeba
- Associate Professor, Palliative Care Unit, Department of Radiotherapy, Christian Medical College and Hospital, Vellore, India
| | - Rajesh Isiah
- Physician, Department of Radiotherapy, Christian Medical College and Hospital, Vellore, India
| | - J Subhashini
- Professor, Department of Radiotherapy, Christian Medical College and Hospital, Vellore, India
| | - Selvamani Backianathan
- Professor, Department of Radiotherapy, Christian Medical College and Hospital, Vellore, India
| | - Balamugesh Thangakunam
- Professor, Department of Pulmonary Medicine, Christian Medical College and Hospital, Vellore, India
| | | |
Collapse
|
26
|
Reducing Heart dose during Left Breast Cancer Radiotherapy: Comparison among 3 Radiation Techniques. TUMORI JOURNAL 2015; 102:184-9. [DOI: 10.5301/tj.5000414] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 07/20/2015] [Indexed: 12/25/2022]
Abstract
Purpose Breast cancer survivors have a high risk of cardiac death as a consequence of heart irradiation during left breast tangential radiotherapy (RT). This study compares the cardiac dose delivered by standard 3D conformal tangential RT (CRT) to that delivered by prospective-gating RT (PGRT) or 5-field intensity-modulated RT (IMRT). Methods Patients with early left breast cancer, referred for adjuvant RT to our institution, were enrolled in this study. For each patient, 2 simulation computed tomography scans were acquired: the first during free breathing, and the second on prospective gating during deep inspiration breath-hold. The scans were monitored by the Varian RPM™ respiratory gating system. For each patient, 3 treatment plans were performed: a 3D-CRT and an IMRT plan, each based on the free-breathing scan, and a PGRT plan, based on the deep inspiration breath-hold scan. Dose-volume histograms were compared by means of the Friedman test. Results The median mean heart dose was 3 Gy (range 0.9-7.3 Gy) in the CRT plans, 1.9 Gy (range 0.5-3.6 Gy) in the PGRT plans, and 4.5 Gy (range 1.1-10.5 Gy) in the IMRT plans (p = 0.001). The mean heart V25 was 1.2% (range 0%-9.7%), 0% (range 0%-2.0%), and 0.2% (range 0%-7.3%) for CRT, PGRT, and IMRT plans, respectively (p<0.001). Conclusions Prospective-gating RT to the left breast offered the best protection of heart and lung, as well as a lower irradiation of the contralateral breast, compared to CRT or IMRT.
Collapse
|
27
|
Edvardsson A, Nilsson MP, Amptoulach S, Ceberg S. Comparison of doses and NTCP to risk organs with enhanced inspiration gating and free breathing for left-sided breast cancer radiotherapy using the AAA algorithm. Radiat Oncol 2015; 10:84. [PMID: 25884950 PMCID: PMC4465142 DOI: 10.1186/s13014-015-0375-y] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2014] [Accepted: 03/08/2015] [Indexed: 12/25/2022] Open
Abstract
Background The purpose of this study was to investigate the potential dose reduction to the heart, left anterior descending (LAD) coronary artery and the ipsilateral lung for patients treated with tangential and locoregional radiotherapy for left-sided breast cancer with enhanced inspiration gating (EIG) compared to free breathing (FB) using the AAA algorithm. The radiobiological implication of such dose sparing was also investigated. Methods Thirty-two patients, who received tangential or locoregional adjuvant radiotherapy with EIG for left-sided breast cancer, were retrospectively enrolled in this study. Each patient was CT-scanned during FB and EIG. Similar treatment plans, with comparable target coverage, were created in the two CT-sets using the AAA algorithm. Further, the probability of radiation induced cardiac mortality and pneumonitis were calculated using NTCP models. Results For tangential treatment, the median V25Gy for the heart and LAD was decreased for EIG from 2.2% to 0.2% and 40.2% to 0.1% (p < 0.001), respectively, whereas there was no significant difference in V20Gy for the ipsilateral lung (p = 0.109). For locoregional treatment, the median V25Gy for the heart and LAD was decreased for EIG from 3.3% to 0.2% and 51.4% to 5.1% (p < 0.001), respectively, and the median ipsilateral lung V20Gy decreased from 27.0% for FB to 21.5% (p = 0.020) for EIG. The median excess cardiac mortality probability decreased from 0.49% for FB to 0.02% for EIG (p < 0.001) for tangential treatment and from 0.75% to 0.02% (p < 0.001) for locoregional treatment. There was no significant difference in risk of radiation pneumonitis for tangential treatment (p = 0.179) whereas it decreased for locoregional treatment from 6.82% for FB to 3.17% for EIG (p = 0.004). Conclusions In this study the AAA algorithm was used for dose calculation to the heart, LAD and left lung when comparing the EIG and FB techniques for tangential and locoregional radiotherapy of breast cancer patients. The results support the dose and NTCP reductions reported in previous studies where dose calculations were performed using the pencil beam algorithm.
Collapse
Affiliation(s)
- Anneli Edvardsson
- Department of Medical Radiation Physics, Lund University, Lund, Sweden.
| | - Martin P Nilsson
- Department of Oncology and Radiation Physics, Skåne University Hospital, Lund, Sweden.
| | - Sousana Amptoulach
- Department of Oncology and Radiation Physics, Skåne University Hospital, Malmö, Sweden.
| | - Sofie Ceberg
- Department of Oncology and Radiation Physics, Skåne University Hospital, Lund, Sweden.
| |
Collapse
|
28
|
Sanzari JK, Krigsfeld GS, Shuman AL, Diener AK, Lin L, Mai W, Kennedy AR. Effects of a granulocyte colony stimulating factor, Neulasta, in mini pigs exposed to total body proton irradiation. LIFE SCIENCES IN SPACE RESEARCH 2015; 5:13-20. [PMID: 25909052 PMCID: PMC4402939 DOI: 10.1016/j.lssr.2015.03.002] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
Astronauts could be exposed to solar particle event (SPE) radiation, which is comprised mostly of proton radiation. Proton radiation is also a treatment option for certain cancers. Both astronauts and clinical patients exposed to ionizing radiation are at risk for loss of white blood cells (WBCs), which are the body's main defense against infection. In this report, the effect of Neulasta treatment, a granulocyte colony stimulating factor, after proton radiation exposure is discussed. Mini pigs exposed to total body proton irradiation at a dose of 2 Gy received 4 treatments of either Neulasta or saline injections. Peripheral blood cell counts and thromboelastography parameters were recorded up to 30 days post-irradiation. Neulasta significantly improved WBC loss, specifically neutrophils, in irradiated animals by approximately 60% three days after the first injection, compared to the saline treated, irradiated animals. Blood cell counts quickly decreased after the last Neulasta injection, suggesting a transient effect on WBC stimulation. Statistically significant changes in hemostasis parameters were observed after proton radiation exposure in both the saline and Neulasta treated irradiated groups, as well as internal organ complications such as pulmonary changes. In conclusion, Neulasta treatment temporarily alleviates proton radiation-induced WBC loss, but has no effect on altered hemostatic responses.
Collapse
Affiliation(s)
- Jenine K. Sanzari
- Department of Radiation Oncology, University of Pennsylvania, Philadelphia, PA
| | | | - Anne L. Shuman
- Department of Radiation Oncology, University of Pennsylvania, Philadelphia, PA
| | - Antonia K. Diener
- Department of Radiation Oncology, University of Pennsylvania, Philadelphia, PA
| | - Liyong Lin
- Department of Radiation Oncology, University of Pennsylvania, Philadelphia, PA
| | - Wilfried Mai
- Radiology, University of Pennsylvania School of Veterinary Medicine, Philadelphia, PA
| | - Ann R. Kennedy
- Department of Radiation Oncology, University of Pennsylvania, Philadelphia, PA
| |
Collapse
|
29
|
The impact of inter-fraction set-up errors on the probability of pulmonary and cardiac complication in left-sided breast cancer patients. JOURNAL OF RADIOTHERAPY IN PRACTICE 2014. [DOI: 10.1017/s1460396914000065] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
AbstractPurposeThis study evaluated the impact of patient set-up errors on the probability of pulmonary and cardiac complications in the irradiation of left-sided breast cancer.Methods and materialsUsing the CMS XiO Version 4·6 radiotherapy planning system's normal tissue complication probability (NTCP) algorithm and the Lyman–Kutcher–Burman model, we calculated the dose–volume histograms (DVH) indices for the ipsilateral lung and heart and the resultant NTCP for radiation-induced pneumonitis and excess cardiac mortality in 12 left-sided breast cancer patients.ResultsIsocentric shifts in the posterior direction had the greatest effect on the lung V20, heart V25, and mean and maximum doses to the lung and the heart. DVH results show that the ipsilateral lung V20 tolerance was exceeded in 58% of the patients after 1 cm posterior shifts. Similarly, the heart V25 tolerance was exceeded after 1 cm antero-posterior and left–right isocentric shifts in 70% of the patients. The baseline NTCPs for radiation-induced pneumonitis ranged from 0·73% to 3·4%, with a mean value of 1·7%. The maximum reported NTCP for radiation-induced pneumonitis was 5·8% (mean 2·6%) after 1 cm posterior isocentric shift. The NTCP for excess cardiac mortality were 0% in 100% of the patients (n = 12) before and after set-up error simulations.ConclusionsSet-up errors in left-sided breast cancer patients have a statistically significant impact on the Lung NTCPs and DVH indices. However, with a central lung distance of 3 cm or less (CLD < 3 cm), and a maximum heart distance of 1·5 cm or less (MHD < 1·5 cm), the treatment plans could tolerate set-up errors of up to 1 cm without any change in the NTCP to the heart.
Collapse
|
30
|
Myers PA, Mavroidis P, Papanikolaou N, Stathakis S. Comparing conformal, arc radiotherapy and helical tomotherapy in craniospinal irradiation planning. J Appl Clin Med Phys 2014; 15:4724. [PMID: 25207562 PMCID: PMC5711087 DOI: 10.1120/jacmp.v15i5.4724] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2013] [Revised: 06/11/2014] [Accepted: 05/23/2014] [Indexed: 12/16/2022] Open
Abstract
Currently, radiotherapy treatment plan acceptance is based primarily on dosimetric performance measures. However, use of radiobiological analysis to assess benefit in terms of tumor control and harm in terms of injury to normal tissues can be advantageous. For pediatric craniospinal axis irradiation (CSI) patients, in particular, knowing the technique that will optimize the probabilities of benefit versus injury can lead to better long-term outcomes. Twenty-four CSI pediatric patients (median age 10) were retrospectively planned with three techniques: three-dimensional conformal radiation therapy (3D CRT), volumetric-modulated arc therapy (VMAT), and helical tomotherapy (HT). VMAT plans consisted of one superior and one inferior full arc, and tomotherapy plans were created using a 5.02cm field width and helical pitch of 0.287. Each plan was normalized to 95% of target volume (whole brain and spinal cord) receiving prescription dose 23.4Gy in 13 fractions. Using an in-house MATLAB code and DVH data from each plan, the three techniques were evaluated based on biologically effective uniform dose (D=), the complication-free tumor control probability (P+), and the width of the therapeutically beneficial range. Overall, 3D CRT and VMAT plans had similar values of D= (24.1 and 24.2 Gy), while HT had a D= slightly lower (23.6 Gy). The average values of the P+ index were 64.6, 67.4, and 56.6% for 3D CRT, VMAT, and HT plans, respectively, with the VMAT plans having a statistically significant increase in P+. Optimal values of D= were 28.4, 33.0, and 31.9 Gy for 3D CRT, VMAT, and HT plans, respectively. Although P+ values that correspond to the initial dose prescription were lower for HT, after optimizing the D= prescription level, the optimal P+ became 94.1, 99.5, and 99.6% for 3D CRT, VMAT, and HT, respectively, with the VMAT and HT plans having statistically significant increases in P+. If the optimal dose level is prescribed using a radiobiological evaluation method, as opposed to a purely dosimetric one, the two IMRT techniques, VMAT and HT, will yield largest overall benefit to CSI patients by maximizing tumor control and limiting normal tissue injury. Using VMAT or HT may provide these pediatric patients with better long-term outcomes after radiotherapy.
Collapse
Affiliation(s)
- Pamela A Myers
- University of Texas Health Science Center at San Antonio.
| | | | | | | |
Collapse
|
31
|
Komisopoulos G, Mavroidis P, Rodriguez S, Stathakis S, Papanikolaou N, Nikiforidis GC, Sakellaropoulos GC. Radiobiologic comparison of helical tomotherapy, intensity modulated radiotherapy, and conformal radiotherapy in treating lung cancer accounting for secondary malignancy risks. Med Dosim 2014; 39:337-47. [DOI: 10.1016/j.meddos.2014.06.001] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2013] [Revised: 05/31/2014] [Accepted: 06/12/2014] [Indexed: 12/25/2022]
|
32
|
Abeyaratne D. Can intensity modulated radiation therapy reduce cardiac dose in left-sided breast patients? ACTA ACUST UNITED AC 2013. [DOI: 10.1002/j.2051-3909.2010.tb00119.x] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Affiliation(s)
- D Abeyaratne
- Peter MacCallum Moorabbin; 865 Centre Road Bentleigh East Victoria 3165 Australia
| |
Collapse
|
33
|
Mavroidis P, Ferreira BC, Papanikolaou N, Lopes MDC. Analysis of fractionation correction methodologies for multiple phase treatment plans in radiation therapy. Med Phys 2013; 40:031715. [PMID: 23464310 DOI: 10.1118/1.4792636] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE Radiation therapy is often delivered by multiple sequential treatment plans. For an accurate radiobiological evaluation of the overall treatment, fractionation corrections to each dose distribution must be applied before summing the three-dimensional dose matrix of each plan since the simpler approach of performing the fractionation correction to the total dose-volume histograms, obtained by the arithmetical sum of the different plans, becomes inaccurate for more heterogeneous dose patterns. In this study, the differences between these two fractionation correction methods, named here as exact (corrected before) and approximate (after summation), respectively, are assessed for different cancer types. METHODS Prostate, breast, and head and neck (HN) tumor patients were selected to quantify the differences between two fractionation correction methods (the exact vs the approximate). For each cancer type, two different treatment plans were developed using uniform (CRT) and intensity modulated beams (IMRT), respectively. The responses of the target and normal tissue were calculated using the Poisson linear-quadratic-time model and the relative seriality model, respectively. All treatments were radiobiologically evaluated and compared using the complication-free tumor control probability (P+), the biologically effective uniform dose (D) together with common dosimetric criteria. RESULTS For the prostate cancer patient, an underestimation of around 14%-15% in P+ was obtained when the fractionation correction was applied after summation compared to the exact approach due to significant biological and dosimetric variations obtained between the two fractionation correction methods in the involved lymph nodes. For the breast cancer patient, an underestimation of around 3%-4% in the maximum dose in the heart was obtained. Despite the dosimetric differences in this organ, no significant variations were obtained in treatment outcome. For the HN tumor patient, an underestimation of about 5% in treatment outcome was obtained for the CRT plan as a result of an underestimation of the planning target volume control probability by about 10%. An underestimation of about 6% in the complication probability of the right parotid was also obtained. For all the other organs at risk, dosimetric differences of up to 4% were obtained but with no significant impact in the expected clinical outcome. However, for the IMRT plan, an overestimation in P+ of 4.3% was obtained mainly due to an underestimation of the complication probability of the left and right parotids (2.9% and 5.8%, respectively). CONCLUSIONS The use of the exact fractionation correction method, which is applying fractionation correction on the separate dose distributions of a multiple phase treatment before their summation was found to have a significant expected clinical impact. For regions of interest that are irradiated with very heterogeneous dose distributions and significantly different doses per fraction in the different treatment phases, the exact fractionation correction method needs to be applied since a significant underestimation of the true patient outcome can be introduced otherwise.
Collapse
Affiliation(s)
- Panayiotis Mavroidis
- Department of Radiation Oncology, University of Texas Health Sciences Center, San Antonio, Texas 78229, USA.
| | | | | | | |
Collapse
|
34
|
Hedin E, Bäck A. Influence of different dose calculation algorithms on the estimate of NTCP for lung complications. J Appl Clin Med Phys 2013; 14:127-39. [PMID: 24036865 PMCID: PMC5714575 DOI: 10.1120/jacmp.v14i5.4316] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2012] [Revised: 04/05/2013] [Accepted: 03/22/2013] [Indexed: 11/23/2022] Open
Abstract
Due to limitations and uncertainties in dose calculation algorithms, different algorithms can predict different dose distributions and dose-volume histograms for the same treatment. This can be a problem when estimating the normal tissue complication probability (NTCP) for patient-specific dose distributions. Published NTCP model parameters are often derived for a different dose calculation algorithm than the one used to calculate the actual dose distribution. The use of algorithm-specific NTCP model parameters can prevent errors caused by differences in dose calculation algorithms. The objective of this work was to determine how to change the NTCP model parameters for lung complications derived for a simple correction-based pencil beam dose calculation algorithm, in order to make them valid for three other common dose calculation algorithms. NTCP was calculated with the relative seriality (RS) and Lyman-Kutcher-Burman (LKB) models. The four dose calculation algorithms used were the pencil beam (PB) and collapsed cone (CC) algorithms employed by Oncentra, and the pencil beam convolution (PBC) and anisotropic analytical algorithm (AAA) employed by Eclipse. Original model parameters for lung complications were taken from four published studies on different grades of pneumonitis, and new algorithm-specific NTCP model parameters were determined. The difference between original and new model parameters was presented in relation to the reported model parameter uncertainties. Three different types of treatments were considered in the study: tangential and locoregional breast cancer treatment and lung cancer treatment. Changing the algorithm without the derivation of new model parameters caused changes in the NTCP value of up to 10 percentage points for the cases studied. Furthermore, the error introduced could be of the same magnitude as the confidence intervals of the calculated NTCP values. The new NTCP model parameters were tabulated as the algorithm was varied from PB to PBC, AAA, or CC. Moving from the PB to the PBC algorithm did not require new model parameters; however, moving from PB to AAA or CC did require a change in the NTCP model parameters, with CC requiring the largest change. It was shown that the new model parameters for a given algorithm are different for the different treatment types.
Collapse
|
35
|
Bufacchi A, Nardiello B, Capparella R, Begnozzi L. Clinical implications in the use of the PBC algorithm versus the AAA by comparison of different NTCP models/parameters. Radiat Oncol 2013; 8:164. [PMID: 23826854 PMCID: PMC3750611 DOI: 10.1186/1748-717x-8-164] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2012] [Accepted: 06/13/2013] [Indexed: 12/25/2022] Open
Abstract
Purpose Retrospective analysis of 3D clinical treatment plans to investigate qualitative, possible, clinical consequences of the use of PBC versus AAA. Methods The 3D dose distributions of 80 treatment plans at four different tumour sites, produced using PBC algorithm, were recalculated using AAA and the same number of monitor units provided by PBC and clinically delivered to each patient; the consequences of the difference on the dose-effect relations for normal tissue injury were studied by comparing different NTCP model/parameters extracted from a review of published studies. In this study the AAA dose calculation is considered as benchmark data. The paired Student t-test was used for statistical comparison of all results obtained from the use of the two algorithms. Results In the prostate plans, the AAA predicted lower NTCP value (NTCPAAA) for the risk of late rectal bleeding for each of the seven combinations of NTCP parameters, the maximum mean decrease was 2.2%. In the head-and-neck treatments, each combination of parameters used for the risk of xerostemia from irradiation of the parotid glands involved lower NTCPAAA, that varied from 12.8% (sd=3.0%) to 57.5% (sd=4.0%), while when the PBC algorithm was used the NTCPPBC’s ranging was from 15.2% (sd=2.7%) to 63.8% (sd=3.8%), according the combination of parameters used; the differences were statistically significant. Also NTCPAAA regarding the risk of radiation pneumonitis in the lung treatments was found to be lower than NTCPPBC for each of the eight sets of NTCP parameters; the maximum mean decrease was 4.5%. A mean increase of 4.3% was found when the NTCPAAA was calculated by the parameters evaluated from dose distribution calculated by a convolution-superposition (CS) algorithm. A markedly different pattern was observed for the risk relating to the development of pneumonitis following breast treatments: the AAA predicted higher NTCP value. The mean NTCPAAA varied from 0.2% (sd = 0.1%) to 2.1% (sd = 0.3%), while the mean NTCPPBC varied from 0.1% (sd = 0.0%) to 1.8% (sd = 0.2%) depending on the chosen parameters set. Conclusions When the original PBC treatment plans were recalculated using AAA with the same number of monitor units provided by PBC, the NTCPAAA was lower than the NTCPPBC, except for the breast treatments. The NTCP is strongly affected by the wide-ranging values of radiobiological parameters.
Collapse
Affiliation(s)
- Antonella Bufacchi
- Medical Physics, PioXI Clinic and UOC Medical Physics, S Giovanni Calibita Fatebenefratelli Hospital, Rome, Italy.
| | | | | | | |
Collapse
|
36
|
Tzikas A, Komisopoulos G, Ferreira BC, Hyödynmaa S, Axelsson S, Papanikolaou N, Lavdas E, Lind BK, Mavroidis P. Radiobiological Evaluation of Breast Cancer Radiotherapy Accounting for the Effects of Patient Positioning and Breathing in Dose Delivery. A Meta Analysis. Technol Cancer Res Treat 2013; 12:31-44. [DOI: 10.7785/tcrt.2012.500274] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022] Open
Abstract
In breast cancer radiotherapy, significant discrepancies in dose delivery can contribute to underdosage of the tumor or overdosage of normal tissue, which is potentially related to a reduction of local tumor control and an increase of side effects. To study the impact of these factors in breast cancer radiotherapy, a meta analysis of the clinical data reported by Mavroidis et al. (2002) in Acta Oncol (41:471–85), showing the patient setup and breathing uncertainties characterizing three different irradiation techniques, were employed. The uncertainties in dose delivery are simulated based on fifteen breast cancer patients (5 mastectomized, 5 resected with negative node involvement (R-) and 5 resected with positive node involvement (R+)), who were treated by three different irradiation techniques, respectively. The positioning and breathing effects were taken into consideration in the determination of the real dose distributions delivered to the CTV and lung in each patient. The combined frequency distributions of the positioning and breathing distributions were obtained by convolution. For each patient the effectiveness of the dose distribution applied is calculated by the Poisson and relative seriality models and a set of parameters that describe the dose-response relations of the target and lung. The three representative radiation techniques are compared based on radiobiological measures by using the complication-free tumor control probability, P+ and the biologically effective uniform dose, D̿ concepts. For the Mastectomy case, the average P+ values of the planned and delivered dose distributions are 93.8% for a D̿CTV of 51.8 Gy and 85.0% for a D̿CTV of 50.3 Gy, respectively. The respective total control probabilities, PB values are 94.8% and 92.5%, whereas the corresponding total complication probabilities, PI values are 0.9% and 7.4%. For the R- case, the average P+ values are 89.4% for a D̿CTV of 48.9 Gy and 88.6% for a D̿CTV of 49.0 Gy, respectively. The respective PB values are 89.8% and 89.9%, whereas the corresponding PI values are 0.4% and 1.2%. For the R+ case, the average P+ values are 86.1% for a D̿CTV of 49.2 Gy and 85.5% for a D̿CTV of 49.1 Gy, respectively. The respective PB values are 90.2% and 90.1%, whereas the corresponding PI values are 4.1% and 4.6%. The combined effects of positioning uncertainties and breathing can introduce a significant deviation between the planned and delivered dose distributions in lung in breast cancer radiotherapy. The positioning and breathing uncertainties do not affect much the dose distribution to the CTV. The simulated delivered dose distributions show larger lung complication probabilities than the treatment plans. This means that in clinical practice the true expected complications are underestimated. Radiation pneumonitis of Grade 1–2 is more frequent and any radiotherapy optimization should use this as a more clinically relevant endpoint.
Collapse
Affiliation(s)
- Athanasios Tzikas
- Department of Medical Radiation Physics, Karolinska Institutet and Stockholm University, Sweden
| | | | | | - Simo Hyödynmaa
- Department of Oncology, Tampere University Hospital, Tampere, Finland
| | - Sofie Axelsson
- Department of Medical Radiation Physics, Karolinska Institutet and Stockholm University, Sweden
| | - Nikos Papanikolaou
- Department of Radiological Sciences, University of Texas Health Science Center, San Antonio, Texas, USA
| | - Eleftherios Lavdas
- Department of Radiology, University Hospital of Larissa, Larissa, Greece
| | - Bengt K. Lind
- Department of Medical Radiation Physics, Karolinska Institutet and Stockholm University, Sweden
| | - Panayiotis Mavroidis
- Department of Medical Radiation Physics, Karolinska Institutet and Stockholm University, Sweden
| |
Collapse
|
37
|
|
38
|
Vogelius IR, Bentzen SM. A literature-based meta-analysis of clinical risk factors for development of radiation induced pneumonitis. Acta Oncol 2012; 51:975-83. [PMID: 22950387 DOI: 10.3109/0284186x.2012.718093] [Citation(s) in RCA: 158] [Impact Index Per Article: 13.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
INTRODUCTION The risk of developing side effects after radiotherapy is not only dependent on radiation dose, but may also be affected by patient-related risk factors. Here we perform a literature-based meta-analysis to estimate the effect of various clinical risk factors on the incidence of symptomatic radiation pneumonitis (RP). MATERIAL AND METHODS A systematic review of English language articles in the Pubmed, Embase and Cochrane controlled trials registers. Studies with the mesh term "radiation pneumonitis" or the search term "radiation pneumonitis" were included. Additional studies were identified by manual searching of the references. Studies reporting crude incidence or odds ratios (OR) for radiation pneumonitis vs. age, disease location, smoking status, chemotherapy schedule or comorbidity were included. A systematic overview (meta-analysis) was conducted to synthesize data across multiple studies. RESULTS Significant risk factors for RP were: older age (OR = 1.7, p < 0.0001); disease located in mid-lower lung (OR = 1.9, p = 0.002); presence of comorbidity (OR = 2.3, p = 0.007). Ongoing smoking was found to protect against RP (OR = 0.6, p = 0.008). History of smoking tended to protect against RP (OR = 0.7, p = 0.06). Sequential (rather than concomitant) chemotherapy scheduling (OR = 1.6, p = 0.01) increased RP risk, but treatment intensity and patients selection are likely confounders. CONCLUSION This systematic overview revealed several clinical risk factors for RP that have not been unambiguously identified in the literature. These risk factors should be considered when defining dose-volume constraints for radiation treatment plan optimization.
Collapse
Affiliation(s)
- Ivan R Vogelius
- Department of Radiation Oncology, Rigshospitalet, University of Copenhagen, Denmark
| | | |
Collapse
|
39
|
Tsai PF, Lin SM, Lee SH, Yeh CY, Huang YT, Lee CC, Hong JH. The feasibility study of using multiple partial volumetric-modulated arcs therapy in early stage left-sided breast cancer patients. J Appl Clin Med Phys 2012; 13:3806. [PMID: 22955645 PMCID: PMC5718231 DOI: 10.1120/jacmp.v13i5.3806] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2011] [Revised: 03/01/2012] [Accepted: 04/26/2012] [Indexed: 12/21/2022] Open
Abstract
The purpose of this study was to assess the feasibility of using a multiple partial volumetric‐modulated arcs therapy (MP‐VMAT) technique on the left breast irradiation and to evaluate the dosimetry and treatment efficiency. Ten patients with left‐sided breast cancer who had been treated by whole breast irradiation were selected for the treatment plan evaluation by using six partial volumetric modulated arcs. Each arc consisted of a 50° gantry rotation. The planning target volumes and the normal organs, including the right breast, the bilateral lungs, left ventricle, heart, and unspecified tissue, were contoured on the CT images. Dose‐volume histograms were generated and the delivery time for each arc was recorded. The PTV received greater than 95% of the V95 for all cases, and the maximum dose was within ±1% of 110% of the prescription dose. The mean homogeneity index (HI) was 10.61±0.99, and mean conformity index (CI) was 1.21±0.03. The mean dose, V5, V10, V25, and V30 of the heart were 7.61±1.38 Gy, 59.73% ±15.87%, 24.39% ±6.82%, 2.52% ±1.11%, and 1.57% ±0.71%, respectively. The volume of the left ventricle receiving 25 Gy was 5.15% ±2.23%. The total lung mean dose was 5.57±0.36 Gy, with V5 of 25.39% ±3.88% and V20 of 5.66% ±0.89%. The right breast received a mean dose of 2.13±0.22 Gy, with V5 of 1.83% ±1.22% and V10 of 0.04% ±0.12%. The mean dose of unspecified tissue was 5.34±0.37 Gy and V5 was 22.23% ±1.57%. The volume of the unspecified tissue receiving 50 Gy was 0.50% ±0.14%. The mean delivery time for each arc was 13.9 seconds. The average MU among ten patients was 511 MU (range 443 to 594 MUs). The MP‐VMAT technique for the left‐sided breast cancer patients achieved adequate target dose coverage while maintaining low doses to organs‐at‐risk, and therefore reduced the potential for induction of second malignancy and side effects. The highly efficient treatment delivery would be beneficial for improving patient throughput, providing patient comfort, and achieving precise treatment with the breathing control system. PACS number: 87.55.‐x, 87.55.D‐, 87.55.dk
Collapse
Affiliation(s)
- Ping-Fang Tsai
- Department of Radiation Oncology, Chang Gung Memorial Hospital, Tao-Yuan, Taiwan
| | | | | | | | | | | | | |
Collapse
|
40
|
Giraud P, Djadi-Prat J, Morelle M, Pourel N, Durdux C, Carrie C, Daveau C, Carrère MO, the STIC study centers. Contribution of Respiratory Gating Techniques for Optimization of Breast Cancer Radiotherapy. Cancer Invest 2012; 30:323-30. [DOI: 10.3109/07357907.2012.657818] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Affiliation(s)
- Philippe Giraud
- Department of Radiation Oncology, European Georges-Pompidou Hospital,
Paris Descartes University, Paris, France,1
- Department of Radiation Oncology,2
| | | | - Magalie Morelle
- Curie Institute, Paris, France, CNRS UMR GATE 5824, Léon Bérard Center,
Lyon, France,4
| | - Nicolas Pourel
- Department of Radiation Oncology, Sainte Catherine Institute,
Avignon, France,5
| | - Catherine Durdux
- Department of Radiation Oncology, European Georges-Pompidou Hospital,
Paris Descartes University, Paris, France,1
| | - Christian Carrie
- Department of Radiation Oncology, Léon Bérard Center,
Lyon, France6
| | - Caroline Daveau
- Department of Radiation Oncology, European Georges-Pompidou Hospital,
Paris Descartes University, Paris, France,1
| | - Marie-Odile Carrère
- Curie Institute, Paris, France, CNRS UMR GATE 5824, Léon Bérard Center,
Lyon, France,4
| | | |
Collapse
|
41
|
Predictive Models for Pulmonary Function Changes After Radiotherapy for Breast Cancer and Lymphoma. Int J Radiat Oncol Biol Phys 2012; 82:e257-64. [DOI: 10.1016/j.ijrobp.2011.03.011] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2010] [Revised: 02/28/2011] [Accepted: 03/04/2011] [Indexed: 11/21/2022]
|
42
|
Stereotactic body radiation therapy in non-small-cell lung cancer: linking radiobiological modeling and clinical outcome. Am J Clin Oncol 2011; 34:432-41. [PMID: 20539207 DOI: 10.1097/coc.0b013e3181df4b3f] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
For patients with peripheral, early-stage non-small-cell lung cancer, it has been found feasible to deliver 5 or fewer fractions of large doses through stereotactic body radiation therapy (SBRT) without causing severe early or late injury and with impressive tumor control. In this review, we employ radiobiological modeling with the linear quadratic formulation to explore the adequacy of various dose schedules used for tumor control in the lung as supported by clinical evidence, the influence of dose distribution and delivery time on local control, and how to decrease the likelihood of severe toxicity following SBRT. Furthermore, the validity of the linear quadratic formalism in the high dose range of SBRT for lung cancer is explored.
Collapse
|
43
|
Mavroidis P, Ferreira BC, Lopes MDC. Response-probability volume histograms and iso-probability of response charts in treatment plan evaluation. Med Phys 2011; 38:2382-97. [PMID: 21776773 DOI: 10.1118/1.3570613] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE This study aims at demonstrating a new method for treatment plan evaluation and comparison based on the radiobiological response of individual voxels. This is performed by applying them on three different cancer types and treatment plans of different conformalities. Furthermore, their usefulness is examined in conjunction with traditionally applied radiobiological and dosimetric treatment plan evaluation criteria. METHODS Three different cancer types (head and neck, breast and prostate) were selected to quantify the benefits of the proposed treatment plan evaluation method. In each case, conventional conformal radiotherapy (CRT) and intensity modulated radiotherapy (IMRT) treatment configurations were planned. Iso-probability of response charts was produced by calculating the response probability in every voxel using the linear-quadratic-Poisson model and the dose-response parameters of the corresponding structure to which this voxel belongs. The overall probabilities of target and normal tissue responses were calculated using the Poisson and the relative seriality models, respectively. The 3D dose distribution converted to a 2 Gy fractionation, D2(GY) and iso-BED distributions are also shown and compared with the proposed methodology. Response-probability volume histograms (RVH) were derived and compared with common dose volume histograms (DVH). The different dose distributions were also compared using the complication-free tumor control probability, P+, the biologically effective uniform dose, D, and common dosimetric criteria. RESULTS 3D Iso-probability of response distributions is very useful for plan evaluation since their visual information focuses on the doses that are likely to have a larger clinical effect in that particular organ. The graphical display becomes independent of the prescription dose highlighting the local radiation therapy effect in each voxel without the loss of important spatial information. For example, due to the exponential nature of the Poisson distribution, cold spots in the target volumes or hot spots in the normal tissues are much easier to be identified. Response-volume histograms, as DVH, can also be derived and used for plan comparison. RVH are advantageous since by incorporating the radiobiological properties of each voxel they summarize the 3D distribution into 2D without the loss of relevant information. Thus, more clinically relevant radiobiological objectives and constraints could be defined and used in treatment planning optimization. These measures become increasingly important when dose distributions need to be designed according to the microscopic biological properties of tumor and normal tissues. CONCLUSIONS The proposed methods do not aim to replace quantifiers like the probabilities of total tissue response, which ultimately are the quantities of interest to evaluate treatment success. However, iso-probability of response charts and response-probability volume histograms illustrates more clearly the difference in effectiveness between different treatment plans than the information provided by alternative dosimetric data. The use of 3D iso-probability of response distributions could serve as a good descriptor of the effectiveness of a dose distribution indicating primarily the regions in a tissue that dominate its response.
Collapse
Affiliation(s)
- Panayiotis Mavroidis
- Department of Medical Radiation Physics, Karolinska Institutet and Stockholm University, S-17176 Stockholm, Sweden.
| | | | | |
Collapse
|
44
|
The Cambridge Breast Intensity-modulated Radiotherapy Trial: patient- and treatment-related factors that influence late toxicity. Clin Oncol (R Coll Radiol) 2011; 23:662-73. [PMID: 21646002 DOI: 10.1016/j.clon.2011.04.011] [Citation(s) in RCA: 66] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2010] [Revised: 03/17/2011] [Accepted: 03/21/2011] [Indexed: 11/21/2022]
Abstract
AIMS The effect of patient- and treatment-related factors in the development of late normal tissue toxicity after radiotherapy is not yet fully established. The aim of this study was to elucidate the relative importance of such factors in the development of late toxicity after breast-conserving surgery and adjuvant breast radiotherapy. MATERIALS AND METHODS Patient- and treatment-related factors were analysed in 1014 patients who had received adjuvant radiotherapy to the breast in the Cambridge Breast Intensity-modulated Radiotherapy (IMRT) Trial. Late toxicity data were collected using photographic and clinical assessments and patient-reported questionnaires at 2 years after radiotherapy. RESULTS On multivariate analysis, a larger breast volume was statistically significantly associated with the development of breast shrinkage assessed by serial photographs (odds ratio per litre increase in breast volume = 1.98, 95% confidence interval 1.41, 2.78; P < 0.0005), telangiectasia (odds ratio = 3.94, 95% confidence interval 2.49, 6.24; P < 0.0005), breast oedema (odds ratio = 3.65, 95% confidence interval 2.54, 5.24; P < 0.0005) and pigmentation (odds ratio = 1.75, 95% confidence interval 1.21, 2.51; P = 0.003). Current smokers had an increased risk of developing pigmentation (odds ratio = 2.09, 95% confidence interval 1.23, 3.54; P = 0.006). Patients with a moderate or poor post-surgical cosmesis had a greatly increased risk of moderate or poor overall cosmesis (odds ratio = 38.19; 95% confidence interval 21.9, 66.7; P < 0.0005). Postoperative infection requiring antibiotics was associated with increased risk of telangiectasia (odds ratio = 3.39, 95% confidence interval 1.94, 5.91; P < 0.0005) and breast oversensitivity (odds ratio = 1.78, 95% confidence interval 1.27, 2.49; P = 0.001). CONCLUSIONS In this study, the greatest risk factors for the development of late toxicity 2 years after breast-conserving surgery and adjuvant radiotherapy were larger breast volume, baseline pre-radiotherapy surgical cosmesis, postoperative infection and possibly smoking. These factors seem to be more important than relatively small differences in dose inhomogeneity and the addition of boost radiotherapy at 2 years after the completion of radiotherapy. The modification of potentially preventable risk factors, such as postoperative infection and smoking, may limit the development of late toxicity after breast radiotherapy.
Collapse
|
45
|
Varga Z, Cserháti A, Kelemen G, Boda K, Thurzó L, Kahán Z. Role of systemic therapy in the development of lung sequelae after conformal radiotherapy in breast cancer patients. Int J Radiat Oncol Biol Phys 2011; 80:1109-16. [PMID: 21549513 DOI: 10.1016/j.ijrobp.2010.03.044] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2009] [Revised: 03/13/2010] [Accepted: 03/17/2010] [Indexed: 11/25/2022]
Abstract
PURPOSE To analyze the risk of radiogenic lung damage in breast cancer patients after conformal radiotherapy and different forms of systemic treatment. METHODS AND MATERIALS In 328 patients receiving sequential taxane-based chemotherapy, concomitant hormone therapy (tamoxifen or aromatase inhibitors), or no adjuvant systemic therapy, symptomatic and asymptomatic lung sequelae were prospectively evaluated via the detection of visible CT abnormalities, 3 months or 1 year after the completion of the radiotherapy. RESULTS Significant positive associations were detected between the development of both pneumonitis and fibrosis of Grade 1 and patient age, ipsilateral mean lung dose, volume of the ipsilateral lung receiving 20 Gy, and irradiation of the regional lymph nodes. In multivariate analysis, age and mean lung dose proved to be independent predictors of early (odds ratio [OR] = 1.035, 95% confidence interval [CI] 1.011-1.061 and OR = 1.113, 95% CI 1.049-1.181, respectively) and late (OR = 1.074, 95% CI 1.042-1.107 and OR = 1.207, 95% CI 1.124-1.295, respectively) radiogenic lung damage, whereas the role of systemic therapy was significant in the development of Grade 1 lung fibrosis (p = 0.01). Among the various forms of systemic therapy, tamoxifen increased the risk of late lung sequelae (OR = 2.442, 95% CI 1.120-5.326, p = 0.025). No interaction was demonstrated between the administration of systemic therapy and the other above-mentioned parameters as regards the risk of radiogenic lung damage. CONCLUSIONS Our analyses demonstrate the independent role of concomitant tamoxifen therapy in the development of radiogenic lung fibrosis but do not suggest such an effect for the other modes of systemic treatment.
Collapse
Affiliation(s)
- Zoltán Varga
- Department of Oncotherapy, University of Szeged, Szeged, Hungary
| | | | | | | | | | | |
Collapse
|
46
|
Mavroidis P, Su FC, Giantsoudi D, Stathakis S, Komisopoulos G, Shi C, Swanson G, Papanikolaou N. Radiobiological and Dosimetric Analysis of Daily Megavoltage CT Registration on Adaptive Radiotherapy with Helical Tomotherapy. Technol Cancer Res Treat 2011; 10:1-13. [DOI: 10.7785/tcrt.2012.500175] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022] Open
Abstract
Pre-treatment patient repositioning in highly conformal image-guided radiation therapy modalities is a prerequisite for reducing setup uncertainties. In Helical Tomotherapy (HT) treatment, a megavoltage CT (MVCT) image is usually acquired to evaluate daily changes in the patient's internal anatomy and setup position. This MVCT image is subsequently compared to the kilovoltage CT (kVCT) study that was used for dosimetric planning, by applying a registration process. This study aims at investigating the expected effect of patient setup correction using the Hi-Art tomotherapy system by employing radiobiological measures such as the biologically effective uniform dose ([Formula: see text]) and the complication-free tumor control probability ( P+). A new module of the Tomotherapy software (TomoTherapy, Inc, Madison, WI) called Planned Adaptive is employed in this study. In this process the delivered dose can be calculated by using the sinogram for each delivered fraction and the registered MVCT image set that corresponds to the patient's position and anatomical distribution for that fraction. In this study, patients treated for lung, pancreas and prostate carcinomas are evaluated by this method. For each cancer type, a Helical Tomotherapy plan was developed. In each cancer case, two dose distributions were calculated using the MVCT image sets before and after the patient setup correction. The fractional dose distributions were added and renormalized to the total number of fractions planned. The dosimetric and radiobiological differences of the dose distributions with and without patient setup correction were calculated. By using common statistical measures of the dose distributions and the P+ and [Formula: see text] concepts and plotting the tissue response probabilities vs. [Formula: see text] a more comprehensive comparison was performed based on radiobiological measures. For the lung cancer case, at the clinically prescribed dose levels of the dose distributions, with and without patient setup correction, the complication-free tumor control probabilities, P+ are 48.5% and 48.9% for a [Formula: see text] of 53.3 Gy. The respective total control probabilities, PB are 56.3% and 56.5%, whereas the corresponding total complication probabilities, PI are 7.9% and 7.5%. For the pancreas cancer case, at the prescribed dose levels of the two dose distributions, the P+ values are 53.7% and 45.7% for a [Formula: see text] of 54.7 Gy and 53.8 Gy, respectively. The respective PB values are 53.7% and 45.8%, whereas the corresponding PI values are ~0.0% and 0.1%. For the prostate cancer case, at the prescribed dose levels of the two dose distributions, the P+ values are 10.9% for a [Formula: see text] of 75.2 Gy and 11.9% for a [Formula: see text] of 75.4 Gy, respectively. The respective PB values are 14.5% and 15.3%, whereas the corresponding PI values are 3.6% and 3.4%. Our analysis showed that the very good daily patient setup and dose delivery were very close to the intended ones. With the exception of the pancreas cancer case, the deviations observed between the dose distributions with and without patient setup correction were within ±2% in terms of P+. In the radiobiologically optimized dose distributions, the role of patient setup correction using MVCT images could appear to be more important than in the cases of dosimetrically optimized treatment plans were the individual tissue radiosensitivities are not precisely considered.
Collapse
Affiliation(s)
- P. Mavroidis
- Department of Medical Radiation Physics, Karolinska Institutet and Stockholm University, Sweden
- University Hospital of Larissa, Greece
| | - F-C. Su
- Department of Radiological Sciences, University of Texas Health Science Center, San Antonio, Texas, USA
| | - D. Giantsoudi
- Department of Radiological Sciences, University of Texas Health Science Center, San Antonio, Texas, USA
| | - S. Stathakis
- Department of Radiological Sciences, University of Texas Health Science Center, San Antonio, Texas, USA
| | | | - C. Shi
- Department of Radiological Sciences, University of Texas Health Science Center, San Antonio, Texas, USA
| | - G. Swanson
- Department of Radiological Sciences, University of Texas Health Science Center, San Antonio, Texas, USA
| | - N. Papanikolaou
- Department of Radiological Sciences, University of Texas Health Science Center, San Antonio, Texas, USA
| |
Collapse
|
47
|
Mavroidis P, Shi C, Plataniotis GA, Delichas MG, Ferreira BC, Rodriguez S, Lind BK, Papanikolaou N. Comparison of the helical tomotherapy against the multileaf collimator-based intensity-modulated radiotherapy and 3D conformal radiation modalities in lung cancer radiotherapy. Br J Radiol 2011; 84:161-72. [PMID: 20858664 PMCID: PMC3473851 DOI: 10.1259/bjr/89275085] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2009] [Revised: 01/26/2010] [Accepted: 03/03/2010] [Indexed: 12/25/2022] Open
Abstract
OBJECTIVES The aim of this study was to compare three-dimensional (3D) conformal radiotherapy and the two different forms of IMRT in lung cancer radiotherapy. METHODS Cases of four lung cancer patients were investigated by developing a 3D conformal treatment plan, a linac MLC-based step-and-shoot IMRT plan and an HT plan for each case. With the use of the complication-free tumour control probability (P(+)) index and the uniform dose concept as the common prescription point of the plans, the different treatment plans were compared based on radiobiological measures. RESULTS The applied plan evaluation method shows the MLC-based IMRT and the HT treatment plans are almost equivalent over the clinically useful dose prescription range; however, the 3D conformal plan inferior. At the optimal dose levels, the 3D conformal treatment plans give an average P(+) of 48.1% for a effective uniform dose to the internal target volume (ITV) of 62.4 Gy, whereas the corresponding MLC-based IMRT treatment plans are more effective by an average ΔP(+) of 27.0% for a Δ effective uniform dose of 16.3 Gy. Similarly, the HT treatment plans are more effective than the 3D-conformal plans by an average ΔP(+) of 23.8% for a Δ effective uniform dose of 11.6 Gy. CONCLUSION A radiobiological treatment plan evaluation can provide a closer association of the delivered treatment with the clinical outcome by taking into account the dose-response relations of the irradiated tumours and normal tissues. The use of P - effective uniform dose diagrams can complement the traditional tools of evaluation to compare and effectively evaluate different treatment plans.
Collapse
Affiliation(s)
- P Mavroidis
- Department of Medical Radiation Physics, Karolinska Institutet, Stockholm University, Sweden.
| | | | | | | | | | | | | | | |
Collapse
|
48
|
On the use of published radiobiological parameters and the evaluation of NTCP models regarding lung pneumonitis in clinical breast radiotherapy. AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE 2011; 34:69-81. [DOI: 10.1007/s13246-010-0051-3] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/09/2010] [Accepted: 12/20/2010] [Indexed: 11/26/2022]
|
49
|
Vikström J, Hjelstuen MHB, Mjaaland I, Dybvik KI. Cardiac and pulmonary dose reduction for tangentially irradiated breast cancer, utilizing deep inspiration breath-hold with audio-visual guidance, without compromising target coverage. Acta Oncol 2011; 50:42-50. [PMID: 20843181 DOI: 10.3109/0284186x.2010.512923] [Citation(s) in RCA: 121] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
BACKGROUND AND PURPOSE cardiac disease and pulmonary complications are documented risk factors in tangential breast irradiation. Respiratory gating radiotherapy provides a possibility to substantially reduce cardiopulmonary doses. This CT planning study quantifies the reduction of radiation doses to the heart and lung, using deep inspiration breath-hold (DIBH). PATIENTS AND METHODS seventeen patients with early breast cancer, referred for adjuvant radiotherapy, were included. For each patient two CT scans were acquired; the first during free breathing (FB) and the second during DIBH. The scans were monitored by the Varian RPM respiratory gating system. Audio coaching and visual feedback (audio-visual guidance) were used. The treatment planning of the two CT studies was performed with conformal tangential fields, focusing on good coverage (V(95)>98%) of the planning target volume (PTV). Dose-volume histograms were calculated and compared. Doses to the heart, left anterior descending (LAD) coronary artery, ipsilateral lung and the contralateral breast were assessed. RESULTS compared to FB, the DIBH-plans obtained lower cardiac and pulmonary doses, with equal coverage of PTV. The average mean heart dose was reduced from 3.7 to 1.7 Gy and the number of patients with >5% heart volume receiving 25 Gy or more was reduced from four to one of the 17 patients. With DIBH the heart was completely out of the beam portals for ten patients, with FB this could not be achieved for any of the 17 patients. The average mean dose to the LAD coronary artery was reduced from 18.1 to 6.4 Gy. The average ipsilateral lung volume receiving more than 20 Gy was reduced from 12.2 to 10.0%. CONCLUSION respiratory gating with DIBH, utilizing audio-visual guidance, reduces cardiac and pulmonary doses for tangentially treated left sided breast cancer patients without compromising the target coverage.
Collapse
Affiliation(s)
- Johan Vikström
- Department of Radiotherapy, Stavanger University Hospital, Stavanger, Norway.
| | | | | | | |
Collapse
|
50
|
Mavroidis P, Tzikas A, Papanikolaou N, Lind BK. Toolkit for determination of dose-response relations, validation of radiobiological parameters and treatment plan optimization based on radiobiological measures. Technol Cancer Res Treat 2010; 9:523-37. [PMID: 20815424 DOI: 10.1177/153303461000900511] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
Accurately determined dose-response relations of the different tumors and normal tissues should be estimated and used in the clinic. The aim of this study is to demonstrate developed tools that are necessary for determining the dose-response parameters of tumors and normal tissues, for clinically verifying already published parameter sets using local patient materials and for making use of all this information in the optimization and comparison of different treatment plans and radiation techniques. One of the software modules (the Parameter Determination Module) is designed to determine the dose-response parameters of tumors and normal tissues. This is accomplished by performing a maximum likelihood fitting to calculate the best estimates and confidence intervals of the parameters used by different radiobiological models. Another module of this software (the Parameter Validation Module) concerns the validation and compatibility of external or reported dose-response parameters describing tumor control and normal tissue complications. This is accomplished by associating the expected response rates, which are calculated using different models and published parameter sets, with the clinical follow-up records of the local patient population. Finally, the last module of the software (the Radiobiological Plan Evaluation Module) is used for estimating and optimizing the effectiveness a treatment plan in terms of complication-free tumor control, P(+). The use of the Parameter Determination Module is demonstrated by deriving the dose-response relation of proximal esophagus from head and neck cancer radiotherapy. The application of the Parameter Validation Module is illustrated by verifying the clinical compatibility of those dose-response parameters with the examined treatment methodologies. The Radiobiological Plan Evaluation Module is demonstrated by evaluating and optimizing the effectiveness of head and neck cancer treatment plans. The results of the radiobiological evaluation are compared against dosimetric criteria. The presented toolkit appears to be very convenient and efficient for clinical implementation of radiobiological modeling. It can also be used for the development of a clinical data and health information database for assisting the performance of epidemiological studies and the collaboration between different institutions within research and clinical frameworks.
Collapse
Affiliation(s)
- Panayiotis Mavroidis
- Department of Medical Radiation Physics, Karolinska Institutet and Stockholm University, Sweden.
| | | | | | | |
Collapse
|