1
|
Renaud JM, Al-Mallah MH, Soman P, deKemp RA, Beanlands RSB, Arumugam P, Armstrong IS, Prior JO, Madamanchi C, Goonewardena S, Poitrasson-Rivière A, Moody JB, Ficaro EP, Murthy VL. How to differentiate obstructive from non-obstructive CAD: Developments in High-Resolution Regional Quantification of MBF and MFR. J Nucl Cardiol 2024:102023. [PMID: 39179097 DOI: 10.1016/j.nuclcard.2024.102023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2024] [Revised: 08/09/2024] [Accepted: 08/12/2024] [Indexed: 08/26/2024]
Affiliation(s)
| | | | - Prem Soman
- Division of Cardiology and the Heart and Vascular Institute, University of Pittsburgh Medical Center
| | - Robert A deKemp
- National Cardiac PET Centre, University of Ottawa Heart Institute, Ottawa Ontario, Canada
| | - Rob S B Beanlands
- National Cardiac PET Centre, University of Ottawa Heart Institute, Ottawa Ontario, Canada
| | - Parthiban Arumugam
- Nuclear Medicine, Manchester University NHS Foundation Trust, Oxford Road, Manchester, UK
| | - Ian S Armstrong
- Nuclear Medicine, Manchester University NHS Foundation Trust, Oxford Road, Manchester, UK
| | - John O Prior
- Nuclear Medicine and Molecular Imaging Department, Lausanne University Hospital, Lausanne, Switzerland; University of Lausanne, Faculty of Biology and Medicine, Lausanne, Switzerland
| | - Chaitanya Madamanchi
- Division of Cardiovascular Medicine, Department of Internal Medicine, University of Michigan, Ann Arbor, MI
| | - Sascha Goonewardena
- Division of Cardiovascular Medicine, Department of Internal Medicine, University of Michigan, Ann Arbor, MI; VA Ann Arbor Health System, Ann Arbor, MI
| | | | | | | | - Venkatesh L Murthy
- Division of Cardiovascular Medicine, Department of Internal Medicine, University of Michigan, Ann Arbor, MI
| |
Collapse
|
2
|
Shimizu M, Kimura S, Fujii H, Suzuki M, Nishizaki M, Sasano T. Machine Learning for Multi-Vessel Coronary Artery Disease Prediction on Electrocardiogram Gated Single-Photon Emission Computed Tomography. ANNALS OF NUCLEAR CARDIOLOGY 2023; 9:11-18. [PMID: 38058573 PMCID: PMC10696148 DOI: 10.17996/anc.22-00155] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/25/2022] [Revised: 08/08/2022] [Accepted: 08/15/2022] [Indexed: 12/08/2023]
Abstract
Background: Single-photon emission computed tomography (SPECT) encounters difficulties in diagnosing severe multi-vessel coronary artery disease (svMVD) because of balanced ischemia. We estimated the predictive value of electrocardiogram-gated SPECT for svMVD and improved it using machine learning (ML). Methods and results: We enrolled consecutive 335 patients (median age, 74 years; 255 men) who underwent adenosine stress-gated SPECT (99mTechnesium) and coronary angiography. svMVD was defined as three-vessel disease or left main tract stenosis. Predictive models were constructed using statistical and ML methods. Eighteen cases (5%) showed svMVD, and diabetes, summed stress score (SSS), and the max difference among segmental time of stroke volume per cardiac cycle (MDSV: a parameter of left ventricular [LV] end-systolic dyssynchrony) on adenosine stress were independent significant predictors. The area under the receiver operating characteristic curve (AUC) of SSS and MDSV on stress were 0.759 and 0.763, respectively. Conversely, the extra trees classifier and light gradient boosting machine had improved AUC values of 0.826 and 0.870, respectively, and the MDSV on stress and diabetes showed high feature values in the ML models. Conclusion: ML on SPECT helped to improve the diagnostic performance of svMVD and diabetes, and the parameters of LV dyssynchrony played essential roles in the ML predictive models.
Collapse
Affiliation(s)
- Masato Shimizu
- Department of Cardiology, Yokohama Minami Kyosai Hospital, Yokohama, Japan
| | - Shigeki Kimura
- Department of Cardiology, Yokohama Minami Kyosai Hospital, Yokohama, Japan
| | - Hiroyuki Fujii
- Department of Cardiology, Yokohama Minami Kyosai Hospital, Yokohama, Japan
| | - Makoto Suzuki
- Department of Cardiology, Yokohama Minami Kyosai Hospital, Yokohama, Japan
| | | | - Tetsuo Sasano
- Department of Cardiovascular Medicine, Tokyo Medical and Dental University, Tokyo, Japan
| |
Collapse
|
3
|
Miyauchi H, Ono R, Iimori T, Sawada K, Hoshi K, Hirano KI, Kobayashi Y. Modified Algorithm Using Total Count for Calculating Myocardial Washout Rate in Single-Photon Emission Computerized Tomography. ANNALS OF NUCLEAR CARDIOLOGY 2023; 9:19-25. [PMID: 38058583 PMCID: PMC10696154 DOI: 10.17996/anc.22-00172] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/28/2022] [Revised: 09/08/2022] [Accepted: 09/21/2022] [Indexed: 12/08/2023]
Abstract
Background: The arithmetic mean of washout rate (WR) (namely, AMWR) of each segment is a commonly used algorithm for calculating WR from a polar map in single-photon emission computerized tomography (SPECT). However, in this algorithm, uneven radiotracer uptake among segments affects WR calculation. To solve this possible issue, we formulated a modified algorithm for calculating WR based on the total count (namely, TCWR). Methods: The WR of iodine-123-β-methyl-p-iodophenylpentadecanoic acid (BMIPP) was calculated using TCWR and AMWR, and WR values using TCWR and AMWR were compared by disease. Participants included those without cardiovascular diseases (normal), those with CD36 deficiency, triglyceride deposit cardiomyovasculopathy (TGCV), TGCV with old myocardial infarction (OMI), and non-TGCV with OMI. Results: WR values using TCWR and AMWR did not differ significantly in the following groups: normal, 27.4±8.5 and 27.3±8.5% (p=0.97); CD36 deficiency, -3.2±6.5 and -4.1±7.4% (p=0.81); TGCV, 2.4±6.3 and 2.2±6.3% (p=0.93); and TGCV with OMI, -0.9±7.6 and -3.7±8.4% (p=0.32). However, AMWR showed a lower WR than TCWR in non-TGCV with OMI (4.8±8.7 and 18.9±6.7%, p=0.0008). Conclusions: TCWR is suitable for calculating WR using SPECT polar maps even in cases with heterogeneous radiotracer uptake, such as OMIs. TCWR may be applied to measuring the WR of radiopharmaceuticals other than BMIPP in investigating the pathophysiology of heart diseases.
Collapse
Affiliation(s)
- Hideyuki Miyauchi
- Department of Cardiovascular Medicine, Chiba University Graduate School of Medicine, Chiba, Japan
| | - Ryohei Ono
- Department of Cardiovascular Medicine, Chiba University Graduate School of Medicine, Chiba, Japan
| | - Takashi Iimori
- Department of Radiology, Chiba University Hospital, Chiba, Japan
| | - Koichi Sawada
- Department of Radiology, Chiba University Hospital, Chiba, Japan
| | - Keisuke Hoshi
- Department of Pediatrics, The University of Tokyo Hospital, Tokyo, Japan
| | - Ken-ichi Hirano
- Laboratory of Cardiovascular Disease, Novel, Non-invasive, and Nutritional Therapeutics (CNT) and Triglyceride Research Center (TGRC), Department of Triglyceride Science, Graduate School of Medicine, Osaka University, Osaka, Japan
| | - Yoshio Kobayashi
- Department of Cardiovascular Medicine, Chiba University Graduate School of Medicine, Chiba, Japan
| |
Collapse
|
4
|
Chen Z, Nakajima K, Hirano KI, Kamiya T, Yoshida S, Saito S, Kinuya S. Methods of calculating 123I-β-methyl-P-iodophenyl-pentadecanoic acid washout rates in triglyceride deposit cardiomyovasculopathy. Ann Nucl Med 2022; 36:986-997. [PMID: 36155888 PMCID: PMC9587944 DOI: 10.1007/s12149-022-01787-9] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2022] [Accepted: 09/14/2022] [Indexed: 11/29/2022]
Abstract
OBJECTIVE This study aimed to optimize various methods of calculating washout rates (WRs) of 123I-β-methyl-p-iodophenyl-pentadecanoic (BMIPP), as they are essential to diagnose triglyceride deposit cardiomyovasculopathy (TGCV) which is a rare disease entity identified in Japan and has been encoded in Orphanet (ORPHA code 565612). METHODS We calculated WRs of 123I-BMIPP from early (20 min) and delayed (200 min) images. We evaluated six methods of calculating WRs to discriminate TGVC patients (age, 56.8 ± 14.6 y; male, n = 13; female, n = 4) and 21 123I-BMIPP studies were involved including 4 follow-up studies. Washout rates were calculated by two planar methods using anterior images with cardiac and background regions of interest (ROIs) and by four SPECT methods using either array and polar plots or summed short-axis images. The final diagnoses of TGCV were confirmed according to the 2020 diagnostic criteria, and the diagnostic accuracy of WRs calculated using the six methods was analyzed using the area under receiver-operating characteristics curves (ROC-AUC). Multiple scatter-plot matrix methods were evaluated with correlations for comparison. RESULTS All six methods were useful for diagnosis and did not significantly differ. The four SPECT methods showed excellent diagnostic accuracy (AUC 1.0), whereas the planar methods with and without background correction could be acceptable (AUC 0.857 and 0.964, respectively). The WRs were relatively lower for patients with CAD and remarkable metabolic defects than for patients with TGCV but without defects. CONCLUSIONS For the diagnosis of TGCV, the WR cutoff of 10% of 123I-BMIPP functioned well in planar and SPECT discrimination based on computational methods as a classifier. However, calculation optimization should improve TGCV diagnoses.
Collapse
Affiliation(s)
- Zhuoqing Chen
- Department of Nuclear Medicine, Kanazawa University, Kanazawa, Ishikawa Japan
| | - Kenichi Nakajima
- Department of Functional Imaging and Artificial Intelligence, Kanazawa University, Kanazawa, Ishikawa 920-8640 Japan
| | - Ken-ichi Hirano
- Department of Triglyceride Science, Graduate School of Medicine, Osaka University, Suita, Osaka Japan
| | - Takashi Kamiya
- Department of Medical Technology, Osaka University Hospital, Suita, Osaka Japan
| | - Shohei Yoshida
- Department of Cardiology, Kanazawa University Hospital, Kanazawa, Ishikawa Japan
| | - Shintaro Saito
- Department of Nuclear Medicine, Kanazawa University, Kanazawa, Ishikawa Japan
| | - Seigo Kinuya
- Department of Nuclear Medicine, Kanazawa University, Kanazawa, Ishikawa Japan
| |
Collapse
|
5
|
Sugai S, Matsumoto N, Makita A, Kuronuma K, Suzuki Y, Yoda S, Okumura Y, Amano Y. Clinical Utility of a Slow 201Tl Washout Rate in the Detection of Multi-Vessel Coronary Artery Disease Using a Simultaneous Acquisition Rest 99 mTc/Stress 201Tl Protocol and a Semiconducting Gamma Camera. Circ J 2022; 86:1409-1415. [PMID: 35444110 DOI: 10.1253/circj.cj-21-0739] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
BACKGROUND The diagnostic accuracy of stress myocardial perfusion single-photon emission computed tomography (SPECT) to detect coronary artery disease (CAD) is reduced by the balanced reduction of myocardial perfusion in patients with multi-vessel or left main trunk CAD (multi-vessel group). This study investigated the diagnostic performance of a simultaneous acquisition rest 99 mTc/stress 201Tl dual-isotope protocol for myocardial perfusion SPECT (MPS) in a multi-vessel group by examining the assessment of a slow 201Tl washout rate (WR) finding in comparison to the accuracy of perfusion assessments. METHODS AND RESULTS This study enrolled 91 patients who had undergone angiography within 3 months after MPS. The diagnostic performances of perfusion assessments and a slow 201Tl WR parameter were compared using the area under the curve (AUC) in a multi-vessel group of patients with mild ischemia (2≤summed difference score [SDS]≤7). The AUC of a slow WR parameter was significantly larger compared with that for perfusion assessments, in patients with mild ischemia, (AUC, 0.736 vs. 0.504-0.558, P value: <0.01-0.05). CONCLUSIONS Among patients with mild ischemia, a slow 201Tl WR parameter improved the detection of CAD in a multi-vessel group.
Collapse
Affiliation(s)
| | | | - Ayano Makita
- Department of Cardiology, Nihon University Hospital
| | | | | | - Shunichi Yoda
- Division of Cardiology, Department of Medicine, Nihon University School of Medicine
| | - Yasuo Okumura
- Division of Cardiology, Department of Medicine, Nihon University School of Medicine
| | - Yasuo Amano
- Department of Radiology, Nihon University Hospital
| |
Collapse
|
6
|
The application of artificial intelligence in nuclear cardiology. Ann Nucl Med 2022; 36:111-122. [PMID: 35029816 DOI: 10.1007/s12149-021-01708-2] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2021] [Accepted: 12/05/2021] [Indexed: 01/17/2023]
Abstract
A decade of unprecedented progress in artificial intelligence (AI) has demonstrated a lot of interest in medical imaging research including nuclear cardiology. AI has a potential to reduce cost, save time and improve image acquisition, interpretation, and decision-making. This review summarizes recent researches and potential applications of AI in nuclear cardiology and discusses the pitfall of AI.
Collapse
|
7
|
Abstract
Cardiovascular disease is the leading cause of death worldwide. Given the increased availability of radiopharmaceuticals, improved positron emission tomography (PET) camera systems and proven higher diagnostic accuracy, PET is increasingly utilized in the management of various cardiovascular diseases. PET has high temporal and spatial resolution, when compared to Single Photon Emission Computed Tomography. In clinical practice, hybrid imaging with sequential PET and Computed Tomography acquisitions (PET/CT) or concurrent PET and Magnetic Resonance Imaging are standard. This article will review applications of cardiovascular PET/CT including myocardial perfusion, viability, cardiac sarcoidosis/inflammation, and infection.
Collapse
|
8
|
Kato T, Ichikawa H, Miwa K, Okuda K, Shibutani T, Nagaki A, Tsushima H. [A Nationwide Survey on Additional Scan in Nuclear Medicine Imaging]. Nihon Hoshasen Gijutsu Gakkai Zasshi 2020; 76:285-294. [PMID: 32201419 DOI: 10.6009/jjrt.2020_jsrt_76.3.285] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/18/2023]
Abstract
The aim of the present study was to clarify the routine protocols and the frequency of added or omitted imaging on nuclear medicine imaging in Japan. A nationwide survey on routine protocols and current state of added or omitted imaging in major nuclear medicine imaging were performed for Japanese nuclear medicine technologist. The survey showed that the routine protocols were almost 100% fixed, some of the routine protocols were found to be useful and percentage of imaging techniques such as single photon emission computed tomography/computed tomography that increased patient burden and reduced through put were low. Furthermore, the survey showed that additional or omission imaging were frequently performed on bone scintigraphy and positron emission tomography and added or omitted judgements were often depend upon the rule of thumb by nuclear medicine technologist. In this study, we have concluded that the quality of examination and the diagnosis might depend on the knowledge of nuclear medicine technologist, performed added or omitted imaging.
Collapse
Affiliation(s)
- Toyohiro Kato
- Department of Radiology, Toyohashi Municipal Hospital
| | | | - Kenta Miwa
- Department of Radiological Sciences, School of Health Science, International University of Health and Welfare
| | - Koichi Okuda
- Department of Physics, Kanazawa Medical University
| | - Takayuki Shibutani
- Department of Quantum Medical Technology, Faculty of Health Sciences, Kanazawa University
| | - Akio Nagaki
- Department of Radiological Technology, Kurashiki Central Hospital
| | - Hiroyuki Tsushima
- Department of Radiological Sciences, Ibaraki Prefectural University of Health Sciences
| |
Collapse
|
9
|
Ishihara M, Onoguchi M, Shibutani T. Accuracy of washout rate analysis for thallium-201 single-photon emission computed tomography myocardial perfusion imaging using cadmium zinc telluride detectors: A phantom study. JRSM Cardiovasc Dis 2020; 9:2048004019900600. [PMID: 31976070 PMCID: PMC6958653 DOI: 10.1177/2048004019900600] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2019] [Revised: 11/12/2019] [Accepted: 12/16/2019] [Indexed: 11/23/2022] Open
Abstract
Objective The aim of this study was to assess the accuracy of washout rate (WOR) analysis for thallium-201 chloride (201Tl) single-photon emission computed tomography myocardial perfusion imaging data acquired using cadmium zinc telluride detectors and a myocardial phantom. Methods A myocardial phantom was injected with 10.5 MBq 201Tl, and 10-min acquisitions were performed at 0, 24, 46, and 62 h to accommodate natural radioactive decay over time. Global myocardial WOR (global-WOR) and regional WOR (regional-WOR, left anterior descending artery [LAD], right coronary artery [RCA], and left circumflex artery [LCX]) were analyzed between 0 and 24 h (infarction model), 0 and 46 h (ischemia model), and 0 and 62 h (normal model), respectively. We compared the calculated radioactive decay-rate as a reference standard and phantom imaging WOR (phantom-WOR). Results Decay-rate versus phantom-WOR were 20.4% vs. 20.8% (global-WOR), 21.3% (LAD), 21.2% (RCA), and 19.7% (LCX) for the infarction model; 35.4% vs. 35.6% (global-WOR), 35.5% (LAD), 36.2% (RCA), and 35.2% (LCX) for the ischemia model; and 44.5% vs. 45.1% (global-WOR), 45.4% (LAD), 44.7% (RCA), and 43.5% (LCX) for the normal model. Conclusion WOR analysis for 201Tl single-photon emission computed tomography myocardial perfusion imaging using cadmium zinc telluride detectors is a reliable analysis method.
Collapse
Affiliation(s)
| | - Masahisa Onoguchi
- Department of Quantum Medical Technology, Graduate School of Medical Sciences, Kanazawa University, Ishikawa, Japan
| | - Takayuki Shibutani
- Department of Quantum Medical Technology, Graduate School of Medical Sciences, Kanazawa University, Ishikawa, Japan
| |
Collapse
|
10
|
Shibutani T, Okuda K, Ichikawa H, Kato T, Miwa K, Tsushima H, Onoguchi M, Nagaki A. Imaging technology for myocardial perfusion single-photon emission computed tomography 2018 in Japan. Jpn J Radiol 2020; 38:274-282. [PMID: 31919636 DOI: 10.1007/s11604-019-00915-2] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2019] [Accepted: 12/20/2019] [Indexed: 11/24/2022]
Abstract
AIM Recently, nuclear cardiology has dramatically advanced by a new technology development such as the device, short-term acquisition system, image reconstruction algorithm and image analysis. Although these innovations have been gradually employed in routine examinations, we did not investigate the current use of image acquisition, image reconstruction, and image analysis with myocardial perfusion single-photon emission computed tomography (MPS). We investigated the current status of MPS imaging technology in Japan. METHODS We carried out a survey using a Web-based questionnaire system, the opening of which was announced via e-mail, and it was available on a website for 3 months. We collected data on the current use of MPS with 201Tl and/or 99mTc agents with respect to routine protocols, image acquisition, image reconstruction, and image analysis. RESULTS We received responses to the Web-based questionnaire from 178 and 174 people for 99mTc and 201Tl MPS, respectively. The routine protocols of MPS of stress-rest and rest-stress MPS on 1-day protocols with 99mTc were 41.2% and 14.5%, respectively, and the rest-only scan response rate was 23.7%, whereas that of 201Tl MPS was 65.9% with stress-rest MPS, 19.0% with rest-only MPS, and 10.9% with stress-rest MPS adding a rest scan 24 h after injection. The filtered back projection (FBP) method is most commonly used image reconstruction method, yielding 70.5% for 99mTc MPS and 76.8% for 201Tl MPS, including combined FBP and ordered subset expectation maximization method. The results for no-correction (NC) images were 49.2% with 99mTc MPS and 55.2% with 201Tl MPS including the response of NC and combined attenuation correction (AC) and scatter correction (SC) (i.e., ACSC) images. The AC or ACSC images of 99mTc and 201Tl were provided by 30-40% of the institutions surveyed. CONCLUSIONS We investigated the current status of MPS imaging technology in Japan, and found that although the use of various technical developments has been reported, some of these technologies have not been utilized effectively. Hence, we expect that nuclear medicine technology will be used more effectively to improve diagnosis.
Collapse
Affiliation(s)
- Takayuki Shibutani
- Department of Quantum Medical Technology, Institute of Medical, Pharmaceutical and Health Sciences, Kanazawa University, 5-11-80, Kodatsuno, Kanazawa, Ishikawa, Japan.
| | - Koichi Okuda
- Department of Physics, Kanazawa Medical University, Kahoku, Japan
| | - Hajime Ichikawa
- Department of Radiology, Toyohashi Municipal Hospital, Toyohashi, Japan
| | - Toyohiro Kato
- Department of Radiology, Toyohashi Municipal Hospital, Toyohashi, Japan
| | - Kenta Miwa
- Department of Radiological Sciences, School of Health Sciences, International University of Health and Welfare, Ohtawara, Japan
| | - Hiroyuki Tsushima
- Department of Radiological Sciences, Ibaraki Prefectural University of Health Sciences, Ibaraki, Japan
| | - Masahisa Onoguchi
- Department of Quantum Medical Technology, Institute of Medical, Pharmaceutical and Health Sciences, Kanazawa University, 5-11-80, Kodatsuno, Kanazawa, Ishikawa, Japan
| | - Akio Nagaki
- Department of Radiological Technology, Kurashiki Central Hospital, Kurashiki, Japan
| |
Collapse
|
11
|
Effects of atrial fibrillation on myocardial washout rate of thallium-201 on myocardial perfusion single-photon emission computed tomography. Nucl Med Commun 2018; 39:597-600. [DOI: 10.1097/mnm.0000000000000853] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
12
|
Ishihara M, Onoguchi M, Shibutani T. An Exploratory Study of Washout Rate Analysis for Thallium-201 Single-Photon Emission Computed Tomography Myocardial Perfusion Imaging Using Cadmium Zinc Telluride Detectors. Mol Imaging 2018; 17:1536012118782322. [PMID: 29952215 PMCID: PMC6077886 DOI: 10.1177/1536012118782322] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
The aim of this study was to assess the washout rate (WOR) for thallium-201-chloride single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI) using cadmium zinc telluride detectors for SPECT (CZT SPECT) versus conventional Anger-type SPECT (conventional SPECT). A total of 52 Japanese patients were examined using CZT SPECT and conventional SPECT, and the global WORs were compared. Additionally, the MPI WORs were compared for patients with a normal MPI versus those in whom MPI reflected the patients’ multivessel disease (MVD) MPI. Washout rates were similar when approximated by CZT SPECT versus conventional SPECT 12.59 ± 2.26%/h vs 12.57 ± 2.27%/h (P = .997), respectively. The WOR values for CZT SPECT versus conventional SPECT were 13.42%/h (1.53%/h) vs 13.93%/h (1.24%/h) (P = .337), respectively, for 7 normal MPI patients, and 10.64 ± 2.20%/h vs 10.84 ± 2.26%/h (P = .848), respectively, for 7 MVD-MPI patients. The WOR values for normal MPI versus MVD-MPI patients for CZT SPECT were 13.42 ± 1.53%/h vs 10.64 ± 2.20%/h (P = .025), respectively. Thallium-201-chloride WOR values obtained with high-efficiency CZT SPECT, which enabled significantly reduced imaging times and use of a low-dose protocol, were similar to those obtained with conventional SPECT.
Collapse
Affiliation(s)
- Masaru Ishihara
- Department of Radiology, Hyogo Cancer Center, Akashi, Japan
- Department of Quantum Medical Technology, Graduate School of Medical Sciences, Kanazawa University, Kanazawa, Japan
| | - Masahisa Onoguchi
- Department of Quantum Medical Technology, Graduate School of Medical Sciences, Kanazawa University, Kanazawa, Japan
- Masahisa Onoguchi, Department of Quantum Medical Technology, Graduate School of Medical Sciences, Kanazawa University, 5-11-80 Kodatsuno, Kanazawa 920-0942, Japan.
| | - Takayuki Shibutani
- Department of Quantum Medical Technology, Graduate School of Medical Sciences, Kanazawa University, Kanazawa, Japan
| |
Collapse
|
13
|
Murthy VL, Bateman TM, Beanlands RS, Berman DS, Borges-Neto S, Chareonthaitawee P, Cerqueira MD, deKemp RA, DePuey EG, Dilsizian V, Dorbala S, Ficaro EP, Garcia EV, Gewirtz H, Heller GV, Lewin HC, Malhotra S, Mann A, Ruddy TD, Schindler TH, Schwartz RG, Slomka PJ, Soman P, Di Carli MF, Einstein A, Russell R, Corbett JR. Clinical Quantification of Myocardial Blood Flow Using PET: Joint Position Paper of the SNMMI Cardiovascular Council and the ASNC. J Nucl Cardiol 2018; 25:269-297. [PMID: 29243073 DOI: 10.1007/s12350-017-1110-x] [Citation(s) in RCA: 133] [Impact Index Per Article: 22.2] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Affiliation(s)
- Venkatesh L Murthy
- Frankel Cardiovascular Center, Division of Cardiovascular Medicine, Department of Internal Medicine, University of Michigan, Ann Arbor, MI, USA.
| | | | - Rob S Beanlands
- National Cardiac PET Centre, Division of Cardiology, University of Ottawa Heart Institute, Ottawa, ON, Canada
| | - Daniel S Berman
- Departments of Imaging and Medicine, Cedars-Sinai Medical Center, Los Angeles, CA, USA
| | - Salvador Borges-Neto
- Division of Nuclear Medicine, Department of Radiology, and Division of Cardiology, Department of Medicine, Duke University School of Medicine, Duke University Health System, Durham, NC, USA
| | | | | | - Robert A deKemp
- National Cardiac PET Centre, Division of Cardiology, University of Ottawa Heart Institute, Ottawa, ON, Canada
| | - E Gordon DePuey
- Division of Nuclear Medicine, Department of Radiology, Mt. Sinai St. Luke's and Mt. Sinai West Hospitals, Icahn School of Medicine at Mt. Sinai, New York, NY, USA
| | - Vasken Dilsizian
- Department of Diagnostic Radiology and Nuclear Medicine, University of Maryland School of Medicine, Baltimore, MD, USA
| | - Sharmila Dorbala
- Cardiovascular Imaging Program, Brigham and Women's Hospital, Boston, MA, USA
| | - Edward P Ficaro
- Division of Nuclear Medicine, University of Michigan, Ann Arbor, MI, USA
| | - Ernest V Garcia
- Department of Radiology and Imaging Sciences, Emory University, Atlanta, GA, USA
| | - Henry Gewirtz
- Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA
| | - Gary V Heller
- Gagnon Cardiovascular Institute, Morristown Medical Center, Morristown, NJ, USA
| | | | - Saurabh Malhotra
- Division of Cardiovascular Medicine, Jacobs School of Medicine and Biomedical Sciences, University at Buffalo, Buffalo, NY, USA
| | | | - Terrence D Ruddy
- National Cardiac PET Centre, Division of Cardiology, University of Ottawa Heart Institute, Ottawa, ON, Canada
| | - Thomas H Schindler
- Division of Nuclear Medicine, Department of Radiology, Johns Hopkins School of Medicine, Baltimore, MD, USA
| | - Ronald G Schwartz
- Cardiology Division, Department of Medicine, and Nuclear Medicine Division, Department of Imaging Sciences, University of Rochester Medical Center, Rochester, NY, USA
| | - Piotr J Slomka
- Departments of Imaging and Medicine, Cedars-Sinai Medical Center, Los Angeles, CA, USA
| | - Prem Soman
- Division of Cardiology, Heart and Vascular Institute, University of Pittsburgh Medical Center, Pittsburgh, PA, USA
| | - Marcelo F Di Carli
- Cardiovascular Imaging Program, Brigham and Women's Hospital, Boston, MA, USA
| | - Andrew Einstein
- Division of Cardiology, Department of Medicine, and Department of Radiology, Columbia University Medical Center and New York-Presbyterian Hospital, New York, NY, USA
| | - Raymond Russell
- Warren Alpert Medical School, Brown University, Providence, RI, USA
| | - James R Corbett
- Frankel Cardiovascular Center, Division of Cardiovascular Medicine, Department of Internal Medicine, and Division of Nuclear Medicine, Department of Radiology, University of Michigan, Ann Arbor, MI, USA
| |
Collapse
|
14
|
Murthy VL, Bateman TM, Beanlands RS, Berman DS, Borges-Neto S, Chareonthaitawee P, Cerqueira MD, deKemp RA, DePuey EG, Dilsizian V, Dorbala S, Ficaro EP, Garcia EV, Gewirtz H, Heller GV, Lewin HC, Malhotra S, Mann A, Ruddy TD, Schindler TH, Schwartz RG, Slomka PJ, Soman P, Di Carli MF. Clinical Quantification of Myocardial Blood Flow Using PET: Joint Position Paper of the SNMMI Cardiovascular Council and the ASNC. J Nucl Med 2017; 59:273-293. [PMID: 29242396 DOI: 10.2967/jnumed.117.201368] [Citation(s) in RCA: 147] [Impact Index Per Article: 21.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2017] [Accepted: 09/11/2017] [Indexed: 12/30/2022] Open
Affiliation(s)
- Venkatesh L Murthy
- Frankel Cardiovascular Center, Division of Cardiovascular Medicine, Department of Internal Medicine, University of Michigan, Ann Arbor, Michigan
| | | | - Rob S Beanlands
- National Cardiac PET Centre, Division of Cardiology, University of Ottawa Heart Institute, Ottawa, Ontario, Canada
| | - Daniel S Berman
- Departments of Imaging and Medicine, Cedars-Sinai Medical Center, Los Angeles, California
| | - Salvador Borges-Neto
- Division of Nuclear Medicine, Department of Radiology, and Division of Cardiology, Department of Medicine, Duke University School of Medicine, Duke University Health System, Durham, North Carolina
| | | | | | - Robert A deKemp
- National Cardiac PET Centre, Division of Cardiology, University of Ottawa Heart Institute, Ottawa, Ontario, Canada
| | - E Gordon DePuey
- Division of Nuclear Medicine, Department of Radiology, Mt. Sinai St. Luke's and Mt. Sinai West Hospitals, Icahn School of Medicine at Mt. Sinai, New York, New York
| | - Vasken Dilsizian
- Department of Diagnostic Radiology and Nuclear Medicine, University of Maryland School of Medicine, Baltimore, Maryland
| | - Sharmila Dorbala
- Cardiovascular Imaging Program, Brigham and Women's Hospital, Boston, Massachusetts
| | - Edward P Ficaro
- Division of Nuclear Medicine, University of Michigan, Ann Arbor, Michigan
| | - Ernest V Garcia
- Department of Radiology and Imaging Sciences, Emory University, Atlanta, Georgia
| | - Henry Gewirtz
- Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts
| | - Gary V Heller
- Gagnon Cardiovascular Institute, Morristown Medical Center, Morristown, NJ, USA
| | | | - Saurabh Malhotra
- Division of Cardiovascular Medicine, Jacobs School of Medicine and Biomedical Sciences, University at Buffalo, Buffalo, New York
| | - April Mann
- Hartford Hospital, Hartford, Connecticut
| | - Terrence D Ruddy
- National Cardiac PET Centre, Division of Cardiology, University of Ottawa Heart Institute, Ottawa, Ontario, Canada
| | - Thomas H Schindler
- Division of Nuclear Medicine, Department of Radiology, Johns Hopkins School of Medicine, Baltimore, Maryland
| | - Ronald G Schwartz
- Cardiology Division, Department of Medicine, and Nuclear Medicine Division, Department of Imaging Sciences, University of Rochester Medical Center, Rochester, New York; and
| | - Piotr J Slomka
- Departments of Imaging and Medicine, Cedars-Sinai Medical Center, Los Angeles, California
| | - Prem Soman
- Division of Cardiology, Heart and Vascular Institute, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania
| | - Marcelo F Di Carli
- Cardiovascular Imaging Program, Brigham and Women's Hospital, Boston, Massachusetts
| | | | | |
Collapse
|
15
|
Kurisu S, Sumimoto Y, Ikenaga H, Ishibashi K, Fukuda Y, Kihara Y. Effects of chronic kidney disease on myocardial washout rate of thallium-201 in patients with normal myocardial perfusion on single photon emission computed tomography. Ann Nucl Med 2017; 31:703-708. [DOI: 10.1007/s12149-017-1204-1] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2017] [Accepted: 08/27/2017] [Indexed: 10/18/2022]
|
16
|
Kurisu S, Sumimoto Y, Ikenaga H, Watanabe N, Ishibashi K, Dohi Y, Fukuda Y, Kihara Y. Effects of hemoglobin level on myocardial washout rate of thallium-201 in patients with normal myocardial perfusion assessed by single-photon emission computed tomography. Heart Vessels 2017; 32:1062-1066. [PMID: 28382386 DOI: 10.1007/s00380-017-0975-6] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/21/2016] [Accepted: 03/31/2017] [Indexed: 11/25/2022]
Affiliation(s)
- Satoshi Kurisu
- Department of Cardiovascular Medicine, Hiroshima University Graduate School of Biomedical and Health Sciences, 1-2-3, Kasumi-cho, Minami-ku, Hiroshima, 734-8551, Japan.
| | - Yoji Sumimoto
- Department of Cardiovascular Medicine, Hiroshima University Graduate School of Biomedical and Health Sciences, 1-2-3, Kasumi-cho, Minami-ku, Hiroshima, 734-8551, Japan
| | - Hiroki Ikenaga
- Department of Cardiovascular Medicine, Hiroshima University Graduate School of Biomedical and Health Sciences, 1-2-3, Kasumi-cho, Minami-ku, Hiroshima, 734-8551, Japan
| | - Noriaki Watanabe
- Department of Cardiovascular Medicine, Hiroshima University Graduate School of Biomedical and Health Sciences, 1-2-3, Kasumi-cho, Minami-ku, Hiroshima, 734-8551, Japan
| | - Ken Ishibashi
- Department of Cardiovascular Medicine, Hiroshima University Graduate School of Biomedical and Health Sciences, 1-2-3, Kasumi-cho, Minami-ku, Hiroshima, 734-8551, Japan
| | - Yoshihiro Dohi
- Department of Cardiovascular Medicine, Hiroshima University Graduate School of Biomedical and Health Sciences, 1-2-3, Kasumi-cho, Minami-ku, Hiroshima, 734-8551, Japan
| | - Yukihiro Fukuda
- Department of Cardiovascular Medicine, Hiroshima University Graduate School of Biomedical and Health Sciences, 1-2-3, Kasumi-cho, Minami-ku, Hiroshima, 734-8551, Japan
| | - Yasuki Kihara
- Department of Cardiovascular Medicine, Hiroshima University Graduate School of Biomedical and Health Sciences, 1-2-3, Kasumi-cho, Minami-ku, Hiroshima, 734-8551, Japan
| |
Collapse
|
17
|
Nakanishi R, Gransar H, Slomka P, Arsanjani R, Shalev A, Otaki Y, Friedman JD, Hayes SW, Thomson LEB, Fish M, Germano G, Abidov A, Shaw L, Rozanski A, Berman DS. Predictors of high-risk coronary artery disease in subjects with normal SPECT myocardial perfusion imaging. J Nucl Cardiol 2016; 23:530-41. [PMID: 25971987 PMCID: PMC6377163 DOI: 10.1007/s12350-015-0150-3] [Citation(s) in RCA: 35] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2014] [Revised: 03/30/2015] [Indexed: 11/25/2022]
Abstract
BACKGROUND While uncommon, normal stress SPECT myocardial perfusion imaging (MPI) can be seen in patients with high-risk coronary artery disease (CAD) by invasive coronary angiography (ICA).The predictors of high-risk CAD in patients with normal SPECT-MPI have not been described. METHODS We studied 580 patients (age 64 ± 12 years, 49% men) without known CAD who underwent stress-gated SPECT-MPI [exercise (41%) or vasodilator (59%)] <2 months before ICA and had summed stress score (SSS) <4. High-risk CAD was defined as 3 vessels with ≥70% stenosis, 2 vessels with ≥70% stenosis including proximal left anterior descending, or left main with ≥50% stenosis. Obstructive non-high-risk CAD was defined by the presence of a ≥70% stenosis but without having other high-risk criteria. Tenfold cross-validated receiver operating characteristic (ROC) estimates were obtained to assess the predictors of high-risk CAD. RESULTS Forty-two subjects (7.2%) had high-risk CAD and 168 (29.0%) had obstructive non-high-risk CAD. Variables associated with high-risk CAD were pretest probability of CAD ≥66% (Odds ratio [OR] 3.63, 95% CI 1.6-8.3, P = .002), SSS > 0 (OR 7.46, 95% CI 2.6-21.1, P < 0.001), and abnormal TID (OR 2.16, 95% CI 1.0-4.5, P = 0.044). When substituted for TID, EF change was also predictive of high-risk CAD (OR 0.93, 95% CI 0.9-1.0, P = 0.023). The prevalence of high-risk CAD increased as the number of these predictors increased. In a sub-analysis of patients in whom quantitative total perfusion deficit (TPD) was available, TPD > 0 was also a predictor of high-risk CAD (OR 6.01, 95% CI 1.5-22.2, P = 0.011). CONCLUSION Several clinical, stress, and SPECT-MPI findings are associated high-risk CAD among patients with normal SPECT-MPI. Consideration of these factors may improve the overall assessment of the likelihood of high-risk CAD in patients undergoing stress SPECT-MPI.
Collapse
Affiliation(s)
- Rine Nakanishi
- Departments of Imaging and Medicine, Cedars-Sinai Heart Institute, Cedars Sinai Medical Center, 8700 Beverly Boulevard, Los Angeles, CA, 90048, USA
| | - Heidi Gransar
- Departments of Imaging and Medicine, Cedars-Sinai Heart Institute, Cedars Sinai Medical Center, 8700 Beverly Boulevard, Los Angeles, CA, 90048, USA
| | - Piotr Slomka
- Departments of Imaging and Medicine, Cedars-Sinai Heart Institute, Cedars Sinai Medical Center, 8700 Beverly Boulevard, Los Angeles, CA, 90048, USA
| | - Reza Arsanjani
- Departments of Imaging and Medicine, Cedars-Sinai Heart Institute, Cedars Sinai Medical Center, 8700 Beverly Boulevard, Los Angeles, CA, 90048, USA
| | - Aryeh Shalev
- Departments of Imaging and Medicine, Cedars-Sinai Heart Institute, Cedars Sinai Medical Center, 8700 Beverly Boulevard, Los Angeles, CA, 90048, USA
| | - Yuka Otaki
- Departments of Imaging and Medicine, Cedars-Sinai Heart Institute, Cedars Sinai Medical Center, 8700 Beverly Boulevard, Los Angeles, CA, 90048, USA
| | - John D Friedman
- Departments of Imaging and Medicine, Cedars-Sinai Heart Institute, Cedars Sinai Medical Center, 8700 Beverly Boulevard, Los Angeles, CA, 90048, USA
| | - Sean W Hayes
- Departments of Imaging and Medicine, Cedars-Sinai Heart Institute, Cedars Sinai Medical Center, 8700 Beverly Boulevard, Los Angeles, CA, 90048, USA
| | - Louise E B Thomson
- Departments of Imaging and Medicine, Cedars-Sinai Heart Institute, Cedars Sinai Medical Center, 8700 Beverly Boulevard, Los Angeles, CA, 90048, USA
| | - Mathews Fish
- Oregon Heart and Vascular Institute, Sacred Heart Medical Center, Springfield, OR, USA
| | - Guido Germano
- Departments of Imaging and Medicine, Cedars-Sinai Heart Institute, Cedars Sinai Medical Center, 8700 Beverly Boulevard, Los Angeles, CA, 90048, USA
| | - Aiden Abidov
- Sarver Heart Center, University of Arizona College of Medicine, Tucson, AZ, USA
| | - Leslee Shaw
- Department of Medicine, Emory University, Atlanta, GA, USA
| | - Alan Rozanski
- Division of Cardiology, St. Luke's Roosevelt Hospital, New York, NY, USA
| | - Daniel S Berman
- Departments of Imaging and Medicine, Cedars-Sinai Heart Institute, Cedars Sinai Medical Center, 8700 Beverly Boulevard, Los Angeles, CA, 90048, USA.
- Department of Medicine, David Geffen School of Medicine, University of California, Los Angeles, CA, USA.
| |
Collapse
|
18
|
Tanaka H, Chikamori T, Hida S, Igarashi Y, Shiba C, Usui Y, Hatano T, Yamashina A. Diagnostic Value of Vasodilator-Induced Left Ventricular Dyssynchrony as Assessed by Phase Analysis to Detect Multivessel Coronary Artery Disease. ACTA ACUST UNITED AC 2015. [DOI: 10.17996/anc.15001] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Affiliation(s)
- Hirokazu Tanaka
- Department of Cardiology, Tokyo Medical University Ibaraki Medical Center
| | | | - Satoshi Hida
- Department of Cardiology, Tokyo Medical University
| | | | - Chie Shiba
- Department of Cardiology, Tokyo Medical University
| | | | | | | |
Collapse
|
19
|
Yokota S, Ottervanger JP, Mouden M, Timmer JR, Knollema S, Jager PL. Prevalence, location, and extent of significant coronary artery disease in patients with normal myocardial perfusion imaging. J Nucl Cardiol 2014; 21:284-90. [PMID: 24469846 DOI: 10.1007/s12350-013-9837-5] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2013] [Accepted: 11/27/2013] [Indexed: 10/25/2022]
Abstract
BACKGROUND False-negative myocardial perfusion imaging (MPI) can by due to left main (LM) or three-vessel disease causing "balanced ischemia". However, so far prevalence of LM or three-vessel-disease in patients with normal MPI is unclear. We assessed prevalence, location, and extent of significant coronary artery disease (CAD) in patients with normal MPI. METHODS Between 2006 and 2010, 256 patients with normal MPI who had invasive angiography because of persisting or worsening of the same initial symptoms were studied. Significant CAD was defined as stenosis > 70% or LM > 50%. RESULTS A total of 93 patients (36%) had significant CAD. Significant CAD was observed more frequently in males, higher age and those with typical angina complaints. Significant LM disease was present in 7%, three-vessel disease in 10%, two-vessel disease in 22%, and single vessel disease (not left main) in 61%. In those with single vessel disease, the location was the LAD in 40%, the RCA in 30%, and the LCX in 30%. CONCLUSIONS In selected patients with normal MPI, one-third had significant CAD. The majority of these patients had single vessel disease (not left main). LM or three vessel disease, causing "balanced ischemia", is a less common cause of false-negative MPI.
Collapse
Affiliation(s)
- Shu Yokota
- Department of Cardiology, Isala Klinieken, Dokter Van Heesweg 2, 8025 AB, Zwolle, The Netherlands
| | | | | | | | | | | |
Collapse
|
20
|
Hida S, Chikamori T, Tanaka H, Igarashi Y, Shiba C, Usui Y, Hatano T, Yamashina A. Diagnostic Value of Left Ventricular Dyssynchrony After Exercise and at Rest in the Detection of Multivessel Coronary Artery Disease on Single-Photon Emission Computed Tomography. Circ J 2012; 76:1942-52. [DOI: 10.1253/circj.cj-11-1392] [Citation(s) in RCA: 46] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Affiliation(s)
- Satoshi Hida
- Department of Cardiology, Tokyo Medical University
- Department of Cardiology, Tokyo Medical University
| | - Taishiro Chikamori
- Department of Cardiology, Tokyo Medical University
- Department of Cardiology, Tokyo Medical University
| | - Hirokazu Tanaka
- Department of Cardiology, Tokyo Medical University
- Department of Cardiology, Tokyo Medical University
| | - Yuko Igarashi
- Department of Cardiology, Tokyo Medical University
- Department of Cardiology, Tokyo Medical University
| | - Chie Shiba
- Department of Cardiology, Tokyo Medical University
- Department of Cardiology, Tokyo Medical University
| | - Yasuhiro Usui
- Department of Cardiology, Tokyo Medical University
- Department of Cardiology, Tokyo Medical University
| | - Tsuguhisa Hatano
- Department of Cardiology, Tokyo Medical University
- Department of Cardiology, Tokyo Medical University
| | - Akira Yamashina
- Department of Cardiology, Tokyo Medical University
- Department of Cardiology, Tokyo Medical University
| |
Collapse
|
21
|
Hida S, Chikamori T, Tanaka H, Igarashi Y, Shiba C, Hatano T, Usui Y, Yamashina A. Postischemic myocardial stunning is superior to transient ischemic dilation for detecting multivessel coronary artery disease. Circ J 2011; 76:430-8. [PMID: 22185710 DOI: 10.1253/circj.cj-11-0946] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
BACKGROUND Although poststress myocardial stunning is regarded as a marker for severe coronary artery disease (CAD), no study has yet compared the diagnostic value of poststress stunning with transient ischemic dilation (TID) of the left ventricle (LV) for detecting multivessel CAD. METHODS AND RESULTS A total of 271 patients with suspected or known CAD underwent adenosine triphosphate (ATP) loading and at-rest gated single-photon emission computed tomography. We assessed myocardial perfusion with a 20-segment model, and analyzed the changes in LV volumetric analysis induced by ATP and an automatically derived TID ratio. In 147 patients with multivessel CAD, the prevalence of multi-territorial ischemia was higher, and the post-ATP increase in end-systolic volume (ESV) and TID ratio were greater, than in the 124 with insignificant or single-vessel CAD (P<0.0001, for all cases). The receiver-operating characteristic curves analysis revealed cutoff values for ESV of 5 ml and a TID ratio of 1.11. Multivariate logistic regression analysis revealed that the combination of a poststress increase in ESV of ≥5 ml and multi-territorial ischemia best identified multivessel CAD, with a sensitivity of 78% and a specificity of 84%, whereas the TID ratio was not shown to be an independent predictor. CONCLUSIONS Post-ATP stress myocardial stunning is superior to the TID ratio for detecting multivessel CAD.
Collapse
Affiliation(s)
- Satoshi Hida
- Department of Cardiology, Tokyo Medical University, Japan.
| | | | | | | | | | | | | | | |
Collapse
|
22
|
Normal Tc-99m Tetrofosmin Cardiac SPECT Images With Three-Vessel Coronary Artery Disease. Clin Nucl Med 2010; 35:944-7. [DOI: 10.1097/rlu.0b013e3181f9de68] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
23
|
Alessio AM, Butterworth E, Caldwell JH, Bassingthwaighte JB. Quantitative imaging of coronary blood flow. NANO REVIEWS 2010; 1:NANO-1-5110. [PMID: 22110860 PMCID: PMC3215216 DOI: 10.3402/nano.v1i0.5110] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/10/2010] [Revised: 02/26/2010] [Accepted: 03/01/2010] [Indexed: 11/29/2022]
Abstract
Positron emission tomography (PET) is a nuclear medicine imaging modality based on the administration of a positron-emitting radiotracer, the imaging of the distribution and kinetics of the tracer, and the interpretation of the physiological events and their meaning with respect to health and disease. PET imaging was introduced in the 1970s and numerous advances in radiotracers and detection systems have enabled this modality to address a wide variety of clinical tasks, such as the detection of cancer, staging of Alzheimer's disease, and assessment of coronary artery disease (CAD). This review provides a description of the logic and the logistics of the processes required for PET imaging and a discussion of its use in guiding the treatment of CAD. Finally, we outline prospects and limitations of nanoparticles as agents for PET imaging.
Collapse
Affiliation(s)
| | | | - James H. Caldwell
- Departments of Medicine
- Bioengineering, University of Washington, Seattle, WA, USA
| | - James B. Bassingthwaighte
- Radiology
- Bioengineering, University of Washington, Seattle, WA, USA
- James B. Bassingthwaighte Departments of Bioengineering and Radiology, University of Washington, Seattle, WA 98295-5061, USA.
| |
Collapse
|
24
|
Diamond JA, Makaryus AN, Sandler DA, Machac J, Henzlova MJ. Normal or near normal myocardial perfusion stress imaging in patients with severe coronary artery disease. J Cardiovasc Med (Hagerstown) 2008; 9:820-5. [DOI: 10.2459/jcm.0b013e3282f88bc5] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
|
25
|
Present and future of clinical cardiovascular PET imaging in Europe—a position statement by the European Council of Nuclear Cardiology (ECNC). Eur J Nucl Med Mol Imaging 2008; 35:1709-24. [DOI: 10.1007/s00259-008-0859-1] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2008] [Accepted: 05/16/2008] [Indexed: 01/08/2023]
|
26
|
Abstract
Cardiac positron emission tomography (PET) imaging has advanced from primarily a research tool to a practical, high-performance clinical imaging modality. The widespread availability of state-of-the-art PET gamma cameras, the commercial availability of perfusion and viability PET imaging tracers, reimbursement for PET perfusion and viability procedures by government and private health insurance plans, and the availability of computer software for image display of perfusion, wall motion, and viability images have all been a key to cardiac PET imaging becoming a routine clinical tool. Although myocardial perfusion PET imaging is an option for all patients requiring stress perfusion imaging, there are identifiable patient groups difficult to image with conventional single-photon emission computed tomography imaging that are particularly likely to benefit from PET imaging, such as obese patients, women, patients with previous nondiagnostic tests, and patients with poor left ventricular function attributable to coronary artery disease considered for revascularization. Myocardial PET perfusion imaging with rubidium-82 is noteworthy for high efficiency, rapid throughput, and in a high-volume setting, low operational costs. PET metabolic viability imaging continues to be a noninvasive standard for diagnosis of viability imaging. Cardiac PET imaging has been shown to be cost-effective. The potential of routine quantification of resting and stress blood flow and coronary flow reserve in response to pharmacologic and cold-pressor stress offers tantalizing possibilities of enhancing the power of PET myocardial perfusion imaging. This can be achieved by providing assurance of stress quality control, in enhancing diagnosis and risk stratification in patients with coronary artery disease, and expanding diagnostic imaging into the realm of detection of early coronary artery disease and endothelial dysfunction subject to risk factor modification. Combined PET and x-ray computed tomography imaging (PET-CT) results in enhanced patient throughput and efficiency. The combination of multislice computed tomography scanners with PET opens possibilities of adding coronary calcium scoring and noninvasive coronary angiography to myocardial perfusion imaging and quantification. Evaluation of the clinical role of these creative new possibilities warrants investigation.
Collapse
Affiliation(s)
- Josef Machac
- Department of Radiology, Mount Sinai School of Medicine, Mount Sinai Medical Center, New York, NY 10029, USA.
| |
Collapse
|
27
|
Fukuda H, Moroi M. Prediction of Cardiac Events in Patients With Transient Left Ventricle Dilation on Stress Myocardial Perfusion SPECT Images. Circ J 2005; 69:1223-9. [PMID: 16195621 DOI: 10.1253/circj.69.1223] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
BACKGROUND The purpose of this study was to investigate cardiac events in patients with transient left ventricle (LV) dilation on stress myocardial perfusion single-photon emission computed tomography images (MPI). METHODS AND RESULTS Consecutive patients (n=53, 31 males, mean age 71 years) with transient LV dilation on thallium-201 stress MPI (treadmill: 21, pharmacologic: 32) were followed for 17 months. Follow-up time was censored at the occurrence of cardiac death, congestive heart failure, acute coronary syndrome, or revascularization. Images were scored and then the summed stress score (SSS), summed rest score, and summed difference score were calculated. Cardiac death occurred in 3 patients, hospitalization occurred in 8 patients, and revascularization occurred in 20 patients. The combined cardiac event rate was 59% (76% for exercise stress vs 47% for pharmacologic stress, p=0.034). Cox regression analysis demonstrated that a combination of higher SSS and slow washout rate was the best predictor of cardiac events (hazard ratio =3.3, p=0.029). CONCLUSIONS A high cardiac event rate is associated with transient LV dilation on thallium-201 stress MPI. The event rate is particularly high for exercise stress MPI. Furthermore, a combination of the SSS and thallium-201 slow washout is the best predictor of cardiac events in patients with transient LV dilation.
Collapse
Affiliation(s)
- Hiroshi Fukuda
- Division of Cardiovascular Medicine, Toho University Medical Center, Ohashi Hospital, Tokyo, Japan.
| | | |
Collapse
|
28
|
Kinoshita N, Sugihara H, Adachi Y, Nakamura T, Azuma A, Kohno Y, Nakagawa M. Assessment of transient left ventricular dilatation on rest and exercise on Tc-99m tetrofosmin myocardial SPECT. Clin Nucl Med 2002; 27:34-9. [PMID: 11805482 DOI: 10.1097/00003072-200201000-00008] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
In myocardial perfusion imaging, multiple-vessel involvement of coronary artery disease (CAD) sometimes makes diagnosis difficult. Transient left ventricular (LV) dilatation on Tl-201 myocardial SPECT is a useful finding that enables the clinician to identify patients with multiple-vessel disease. The aim of this study was to confirm the utility of measuring transient LV dilatation for the detection of multiple-vessel CAD in exercise Tc-99m tetrofosmin myocardial SPECT. The participants were 55 CAD patients and 20 controls who underwent Tc-99m tetrofosmin myocardial SPECT exercise and resting imaging. During exercise, 370 MBq (10 mCi) Tc-99m tetrofosmin was injected. Exercise images were obtained 30 minutes after injection. At 210 minutes after injection, 740 MBq (20 mCi) Tc-99m tetrofosmin was administered intravenously. The rest SPECT images were acquired 30 minutes later. Thirty-six radii at every 10 degrees were generated from the center of short-axis images. An area surrounded by 36 maximal points of the myocardial Tc-99m tetrofosmin counts on each radius was calculated for exercise and rest images. The area surrounded by the 36 maximal points in the same slice of the exercise and rest images was assigned the variables A (Ex) and A(R), respectively. The transient dilatation index (TDI) of the left ventricle was calculated using the formula mean A (Ex)/A(R) in the apical, middle, and basal myocardial short-axis images. In the controls, the TDI was 0.970 +/- 0.021. In patients with CAD, the TDIs of one-vessel disease, two-vessel disease, and three-vessel disease were 1.034 +/- 0.032, 1.093 +/- 0.046, and 1.131 +/- 0.076, respectively. The TDIs were significantly greater in patients who had more occluded coronary arteries (P < 0.01). If the mean + 2SD of the TDI (1.012) in controls were assumed to be the normal upper limit, the sensitivity, specificity, and accuracy of this method in detecting two-vessel or three-vessel disease would be 91.4%, 76.9%, and 84%, respectively. The TDI is a useful index for evaluating subendocardial ischemia non-invasively and detecting multiple-vessel disease clinically.
Collapse
|
29
|
Sekiya M, Suzuki J, Watanabe K, Funada J, Otani T, Akutsu H. Beneficial effect of troglitazone, an insulin-sensitizing antidiabetic agent, on coronary circulation in patients with non-insulin-dependent diabetes mellitus. JAPANESE CIRCULATION JOURNAL 2001; 65:487-90. [PMID: 11407727 DOI: 10.1253/jcj.65.487] [Citation(s) in RCA: 18] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Evidence is increasing for small vessel remodeling and disturbance of endothelium-dependent vasodilation in diabetic patients. Insulin increases vascular wall thickening and produces endothelial dysfunction. Troglitazone, a new insulin-sensitizer antidiabetic agent, is considered to reduce plasma insulin level and the present study assessed its effect on the coronary circulation of the patients with non-insulin-dependent diabetes mellitus (NIDDM). Analysis of the myocardial washout rate with adenosine triphosphate-stress thallium-201 scintigraphy was used to estimate coronary circulation, and for estimation of insulin sensitivity, the homeostasis model insulin resistance index (HOMA-R) was calculated. Patients were treated with monotherapy of either troglitazone (200 mg bid, n=12) or glibenclamide (2.5 mg daily, n=12) for 3 months. Age-, sex- and risk factors-matched subjects without NIDDM were employed as a control. Fasting plasma glucose and hemoglobin A1c were similarly decreased by troglitazone or glibenclamide. Plasma insulin level (pmol/L) decreased from 66.6+/-10.8 to 39.0+/-7.2 with troglitazone, but was unchanged by glibenclamide (58.8+/-7.2 to 66.0+/-10.8). The diabetic groups had a significantly lower washout rate than controls, which was improved by troglitazone, but not by glibenclamide. In addition, the increase in washout rate correlated significantly with the decrease in HOMA-R in the troglitazone group. In conclusion, troglitazone can restore coronary circulation by improving insulin resistance in patients with NIDDM.
Collapse
Affiliation(s)
- M Sekiya
- Department of Cardiology, Ehime National Hospital, Onsen-gun, Japan.
| | | | | | | | | | | |
Collapse
|
30
|
Williams KA, Schneider CM. Increased stress right ventricular activity on dual isotope perfusion SPECT: a sign of multivessel and/or left main coronary artery disease. J Am Coll Cardiol 1999; 34:420-7. [PMID: 10440154 DOI: 10.1016/s0735-1097(99)00193-x] [Citation(s) in RCA: 39] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
OBJECTIVES This study sought to determine the anatomic and physiologic correlates of increased right ventricular (RV) activity on exercise single-photon emission computed tomography (SPECT) perfusion imaging in patients with coronary artery disease (CAD). BACKGROUND Because SPECT perfusion imaging delineates relative myocardial blood flow, patients with global left ventricular (LV) hypoperfusion but normal RV perfusion may have increased relative RV tracer uptake as an indicator of multivessel CAD. METHODS Rest thallium-201 and exercise 99mTc-sestamibi or 99mTc-tetrofosmin SPECT perfusion images were analyzed for peak RV and LV activity (RV:LV index) in 315 patients, including 240 patients with documented CAD, 39 patients with no significant CAD on arteriography, and a "normalcy" group of 36 patients with a low pre- and posttest probability of CAD. RESULTS Resting RV:LV perfusion index ranged from 0.32 to 0.34 in each group, increasing to 0.36 with exercise in control and normalcy groups. CAD patients with the highest exercise RV:LV were those with severe left main CAD (or "left main equivalent"), with a lesser degree of proximal right CAD (0.51, n = 14, p < 0.001 vs. other groups). An exercise RV:LV >0.42 with a exercise:rest ratio >1.2 was present in 93% patients with this pattern of CAD, but was absent in 97% of the normalcy group, 92% of patients without significant angiographic CAD, and 100% of patients with proximal right CAD tighter than stenoses in the left system. CONCLUSIONS Increased RV:LV activity exercise may occur in patients with acute RV strain, but is otherwise an indicator of exercise-induced RV:LV perfusion imbalance associated with severe CAD, particularly high-grade left main with less severe proximal right CAD.
Collapse
Affiliation(s)
- K A Williams
- Department of Medicine, The University of Chicago, Illinois 60637, USA.
| | | |
Collapse
|
31
|
Fujiwara S, Takeishi Y, Atsumi H, Chiba J, Takahashi K, Tomoike H. Quantitative assessment of myocardial 99mTc-sestamibi uptake during exercise: usefulness of response rate for assessing severity of coronary artery disease. JAPANESE CIRCULATION JOURNAL 1998; 62:592-8. [PMID: 9741737 DOI: 10.1253/jcj.62.592] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
An increase of 99mTc-sestamibi uptake in the myocardium during exercise was defined as a response rate, and the feasibility of a response rate for detecting coronary artery disease (CAD) was tested. Eighty-seven patients with suspected CAD had myocardial perfusion imaging with 99mTc-sestamibi during exercise and at rest. A dose of 370 MBq of 99mTc-sestamibi was injected at the maximal level of exercise, and a myocardial image was obtained 90 min later (exercise image). Then, 740 MBq of 99mTc-sestamibi was administered at rest, and myocardial imaging was repeated (rest image). The exercise and rest images were corrected for physical decay and injected doses, and the exercise image was subtracted from the rest image to obtain the corrected rest image. A response rate was calculated as follows: (exercise image-corrected rest image)x100/corrected rest image (%). The global response rates of 20 patients without significant coronary stenosis (< or =50%) were higher than those of 67 patients with significant coronary stenosis (81+/-33% and 50+/-28%, p<0.01). Global response rates were correlated with the maximal rate pressure products during exercise (r=0.56, p<0.01) and delta rate pressure products (r=0.53, p<0.01). Regional response rates in myocardial areas perfused by stenotic coronary arteries of < or =50%, 75%, 90% and 99-100% were 60+/-24%,* 56+/-33%,* 40+/-23%* and 30+/-23%,* respectively, (*p<0.01 vs without significant coronary stenosis). The response rates decreased as the severity of coronary artery stenosis advanced, and distinguished between coronary stenoses of graded severity. Accordingly, the response rate from myocardial perfusion imaging with 99mTc-sestamibi may provide complementary information to the conventional inspection with myocardial tomography regarding the severity of CAD.
Collapse
Affiliation(s)
- S Fujiwara
- First Department of Internal Medicine, Yamagata University School of Medicine, Iida-Nishi, Japan.
| | | | | | | | | | | |
Collapse
|
32
|
Hör G. What is the current status of quantification and nuclear medicine in cardiology? EUROPEAN JOURNAL OF NUCLEAR MEDICINE 1996; 23:815-51. [PMID: 8662122 DOI: 10.1007/bf00843713] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Affiliation(s)
- G Hör
- Klinik für Nuklearmedizin, Johann-Wolfgang-Goethe Universität, Theodor-Stern-Kai 7, D-60590 Frankfurt am Main, Germany
| |
Collapse
|
33
|
Mazzanti M, Germano G, Kiat H, Kavanagh PB, Alexanderson E, Friedman JD, Hachamovitch R, Van Train KF, Berman DS. Identification of severe and extensive coronary artery disease by automatic measurement of transient ischemic dilation of the left ventricle in dual-isotope myocardial perfusion SPECT. J Am Coll Cardiol 1996; 27:1612-20. [PMID: 8636545 DOI: 10.1016/0735-1097(96)00052-6] [Citation(s) in RCA: 160] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
OBJECTIVES This study sought to assess whether a transient ischemic dilation ratio, determined from automatically derived stress and rest left ventricular volumes during stress technetium-99m (Tc-99m) sestamibi/rest thallium-201 dual-isotope myocardial perfusion single-photon emission computed tomography (SPECT), is useful for the identification of patients with severe and extensive coronary artery disease. BACKGROUND Transient ischemic dilation of the left ventricle on stress/redistribution thallium-201 scintigraphy has been shown to be a clinically useful marker of severe and extensive coronary artery disease. However, in practice, its assessment is highly subjective. This study automatically assessed the transient ischemic dilation ratio on the basis of a previously described algorithm to estimate three-dimensional ventricular boundaries. METHODS Normal limits for the transient ischemic dilation ratio were developed using data from 54 patients with a low likelihood (< 5%) of coronary artery disease, and criteria for abnormality were developed based on data from 97 who under-went catheterization, of whom 34 had severe and extensive coronary artery disease, defined as > or = 90% stenosis in the proximal left anterior descending coronary artery or in two or more coronary arteries, and 63 had no coronary artery disease (15 patients) or mild to moderate coronary artery disease (48 patients). The criteria were then tested in a validation cohort of 77 additional patients who underwent catheterization, of whom 36 had severe and extensive coronary artery disease. The quantitative results of the dilation ratio were compared with the visual results of the dilation ratio and perfusion defect analysis. RESULTS For normal limits, receiver operating characteristic curve analysis showed that abnormal transient ischemic dilation ratio values corresponded to left ventricular endocardial volume ratios > 1.22 (mean +/- 2 SD). Transient ischemic dilation assessment using these criteria for abnormality showed high sensitivity (24 [71%] of 34) and very high specificity (60 [95%] of 63) for severe and extensive coronary artery disease. When the analysis was applied to the prospective catheterization group, similar sensitivity and specificity for severe and extensive coronary artery disease were observed (77% and 92%, respectively). Significant agreement (p = 0.0001) was found between the degree of transient ischemic dilation and the Tc-99m sestamibi defect extent, the latter assessed by semiquantitative visual analysis (summed stress score). CONCLUSIONS The automatic measurement of transient ischemic dilation in dual-isotope myocardial perfusion SPECT is a clinically useful marker that is sensitive and highly specific for detection of severe and extensive coronary artery disease.
Collapse
Affiliation(s)
- M Mazzanti
- Department of Medicine, Cedars-Sinai Medical Center, Los Angeles, California, USA
| | | | | | | | | | | | | | | | | |
Collapse
|
34
|
Palmas W, Friedman JD, Diamond GA, Silber H, Kiat H, Berman DS. Incremental value of simultaneous assessment of myocardial function and perfusion with technetium-99m sestamibi for prediction of extent of coronary artery disease. J Am Coll Cardiol 1995; 25:1024-31. [PMID: 7897112 DOI: 10.1016/0735-1097(94)00523-s] [Citation(s) in RCA: 46] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Abstract
OBJECTIVES This study assessed the incremental value of technetium-99m myocardial single-photon emission computed tomography (SPECT) and simultaneous first-pass radionuclide angiography, when added to treadmill exercise, for prediction of the extent of coronary artery disease. BACKGROUND Technetium-99m count statistics permit the simultaneous assessment of myocardial perfusion and function. However, whether this characteristic improves prediction of the extent of coronary artery disease remains unknown. METHODS We studied 70 consecutive patients who had coronary angiography within 6 months of the scintigraphic study. All patients underwent a symptom-limited treadmill exercise test. Treadmill data were summarized using a previously validated score. Left ventricular ejection fraction and regional wall motion were evaluated from a first-pass radionuclide angiogram acquired at peak treadmill exercise in the anterior view. Perfusion was assessed visually. Extent of angiographic disease was expressed as the presence or absence of multivessel disease (more than two coronary artery territories with > 50% stenosis) and as a score that reflects the location of severe (> 75%) stenosis. RESULTS Stepwise addition of scintigraphic data (perfusion first, followed by function) to the treadmill score showed significant incremental value for prediction of the angiographic score at each step; exercise ejection fraction alone was the strongest independent predictor. Discriminant accuracy for detection of multivessel disease was also improved by the addition of perfusion information to the treadmill score and addition of regional wall motion analysis to both of them. In this case, ejection fraction failed to show independent value. CONCLUSIONS The addition of simultaneously performed sestamibi perfusion SPECT and first-pass radionuclide angiography to the treadmill exercise test significantly improved prediction of the extent of coronary artery disease.
Collapse
Affiliation(s)
- W Palmas
- Department of Imaging, Cedars-Sinai Medical Center, Los Angeles, California 90048
| | | | | | | | | | | |
Collapse
|
35
|
Garcia MJ, Neumann D, Go RT, Ares MA, Rodriguez L, Griffin BP, Thomas JD. Comparison of persistent thallium perfusion defects by quantitative washout analysis with thallium reinjection in patients with coronary artery disease. Am J Cardiol 1994; 74:977-81. [PMID: 7977057 DOI: 10.1016/0002-9149(94)90843-5] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
Thallium reinjection can improve the detection of severely ischemic viable myocardium in patients with coronary artery disease. However, a disadvantage of this method is that it requires the acquisition of 3 separate sets of images and the administration of an additional dose of the radiotracer. Alternatively, quantitative analysis of the regional myocardial washout of thallium-201 can be easily obtained from the conventional postexercise and redistribution images without additional imaging time or radiation exposure to the patient. To determine whether this method can predict the results of thallium reinjection, this study analyzed thallium-201 images of 31 patients who had persistent perfusion defects in qualitative exercise/delayed redistribution single-photon emission computed tomographic thallium studies and who underwent thallium reinjection. The quantitative mean radioactive counts of each myocardial segment that had a persistent perfusion defect in the initial and delayed redistribution on 4-hour short-axis tomographic slices were measured to derive a delayed/initial ratio, and these values were compared with the results of thallium reinjection. The delayed/initial ratio was 1.06 +/- 0.22 in 39 segments that improved, versus 0.58 +/- 0.18 in 43 segments without improvement after reinjection (p < 0.001). Thirty-eight of the 39 segments that improved had a ratio of > or = 0.75, versus only 3 of the 43 segments that showed no improvement (sensitivity, 98%; specificity, 91%). The correlation between the delayed/initial ratio and reinjection results was equally high at any segment location or severity. It is concluded that quantitative regional thallium washout analysis predicts the results of thallium reinjection in segments with persistent thallium defects.(ABSTRACT TRUNCATED AT 250 WORDS)
Collapse
Affiliation(s)
- M J Garcia
- Cardiovascular Imaging Center, Cleveland Clinic Foundation, Ohio 44195
| | | | | | | | | | | | | |
Collapse
|
36
|
|
37
|
Munck O, Madsen PV, Kelbaek H, Godtfredsen J. Comparison between reference values for 201thallium uptake and washout from the myocardium after exercise and after dipyridamole. CLINICAL PHYSIOLOGY (OXFORD, ENGLAND) 1993; 13:419-27. [PMID: 8370240 DOI: 10.1111/j.1475-097x.1993.tb00341.x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Abstract
A slow washout of 201Thallium has a high diagnostic and prognostic value for coronary artery disease. The aim of the present work was to contribute with reference data on 201Tl uptake and washout from the myocardium. With a quantitative method using circumferential profiles and interpolative background subtraction we performed 201Tl myocardial imaging in two groups of subjects with a low probability of coronary artery disease. Washout in per cent is defined as (1-D/I).100, where D is the delayed uptake rate and I the initial uptake rate. In group A (n = 16) myocardial hyperaemia was induced by maximal exercise, in group B (n = 15) by intravenous infusion of dipyridamole. In group A, the mean washout was 52%, and in group B it was 34% (P < 0.001). The delayed uptake rate D was significantly higher after dipyridamole, 58.4 cps, than after exercise, 44.5 cps (P < 0.05). There was no significant differences in I between the two groups. The findings regarding D and I explain that the washout is slower after dipyridamole than after exercise, as the mean D/I ratio was 0.48 in group A and 0.66 in group B (P < 0.001).
Collapse
Affiliation(s)
- O Munck
- Department of Clinical Physiology and Nuclear Medicine, Herlev Hospital, University of Copenhagen, Denmark
| | | | | | | |
Collapse
|
38
|
Desmarais RL, Kaul S, Watson DD, Beller GA. Do false positive thallium-201 scans lead to unnecessary catheterization? Outcome of patients with perfusion defects on quantitative planar thallium-201 scintigraphy. J Am Coll Cardiol 1993; 21:1058-63. [PMID: 8459058 DOI: 10.1016/0735-1097(93)90225-p] [Citation(s) in RCA: 20] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Abstract
OBJECTIVES We postulated that artifactually abnormal thallium-201 scans are well identified at the time of initial clinical interpretation by experienced readers and do not lead to unnecessary coronary angiography. BACKGROUND Exercise thallium-201 scintigraphy employing quantitative imaging techniques has yielded sensitivity and specificity values of 80% to 90%. There are image artifacts, such as breast shadows, and variants of normal that, if not correctly identified, can lead to a high false positive rate for detection of coronary artery disease. METHODS Data from 338 consecutive patients with one or more focal thallium-201 defects on quantitative planar images were reviewed. All patients had undergone symptom-limited exercise scintigraphy and were classified as having either artifactual or nonartifactual thallium-201 defects after review of clinical reports. RESULTS Of the 265 patients with defects judged to be nonartifactual on clinical readings, 167 underwent coronary angiography, which demonstrated significant coronary artery disease (> or = 50% stenosis) in 161 (96%) and normal findings in 6. Four of the latter six had documented prior myocardial infarction. The remaining 73 patients (85% female) had thallium-201 defects deemed to be artifactual on clinical readings, chiefly as a result of breast (66%) and diaphragmatic (8%) attenuation or variants of normal (26%). Only 4 (5%) of the 73 patients underwent subsequent coronary angiography; none had coronary artery disease. One had aortic stenosis and two had variant angina. Follow-up (mean 20 +/- 2 months) of the 69 patients in this group who did not undergo coronary angiography revealed no deaths and one nonfatal non-Q wave myocardial infarction. CONCLUSIONS Artifactual defects on quantitative planar thallium-201 scintigraphy are well recognized by experienced interpreters and do not result in a high false positive rate leading to unnecessary cardiac catheterization. The incidence of coronary artery disease is high in patients with thallium-201 defects judged to be nonartifactual, and many patients with perfusion defects and angiographically normal coronary arteries have organic heart disease.
Collapse
Affiliation(s)
- R L Desmarais
- Department of Medicine, University of Virginia Health Sciences Center, Charlottesville 22908
| | | | | | | |
Collapse
|
39
|
Datz FL, Gabor FV, Christian PE, Gullberg GT, Menzel CE, Morton KA. The use of computer-assisted diagnosis in cardiac-perfusion nuclear medicine studies: a review. J Digit Imaging 1992; 5:209-22. [PMID: 1457536 DOI: 10.1007/bf03167802] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022] Open
Abstract
The use of computer-assisted diagnosis has become widespread in cardiac nuclear medicine. Quantitative programs are commercially available for ventriculography, phase analysis, and thallium 201 perfusion studies. The goal of these programs is to eliminate interobserver variability by objectively analyzing the studies without causing a loss of accuracy. In addition, by using quantitative data not apparent on visual inspection, some programs attempt to increase sensitivity for disease above that possible by the visual reading of images. Programs that analyze perfusion studies to detect coronary artery disease have received the most interest. Results have varied, but sensitivities as high as 95% have been reported. This review discusses the techniques of computer-assisted diagnosis for thallium 201 myocardial-perfusion studies. The circumferential and washout profile methods are discussed in detail.
Collapse
Affiliation(s)
- F L Datz
- Division of Nuclear Medicine, University of Utah School of Medicine, Salt Lake City 84132
| | | | | | | | | | | |
Collapse
|
40
|
Hurwitz GA, O'Donoghue JP, Powe JE, Gravelle DR, MacDonald AC, Finnie KJ. Pulmonary thallium-201 uptake following dipyridamole-exercise combination compared with single modality stress testing. Am J Cardiol 1992; 69:320-6. [PMID: 1734642 DOI: 10.1016/0002-9149(92)90227-p] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
Angiographic and clinical determinants of pulmonary uptake of thallium-201 were assessed in a laboratory setting where supine bicycle exercise is used for stress testing in the absence of limiting pharmacologic or physical factors, and where symptom-limited exercise is added to intravenous dipyridamole infusion in other cases. Angiographic correlation was available in 400 patients, including 130 tested with exercise, 94 in whom only handgrip or abbreviated bicycle exercise could be used after dipyridamole, and 176 in whom intravenous dipyridamole was combined with a significant level of exercise. For each test mode, lung/myocardial ratios on the immediate image were highly correlated (p less than or equal to 0.001) with a score based on the number of critical coronary artery stenoses, with grading by contrast ventriculography, and with the number of stenosed (greater than or equal to 50%) arteries; relationships (p less than 0.05) to history of myocardial infarction and to gender were also present. Multiple regression analysis showed the critical stenosis score and ventricular dysfunction to be the only significant determinants. When dipyridamole based tests were compared with exercise, curves of receiver-operating characteristics showed a tendency to better diagnostic performance. When dipyridamole is incorporated in stress testing, the value of increased lung uptake as an ancillary diagnostic sign is similar to that established for exercise.
Collapse
Affiliation(s)
- G A Hurwitz
- Department of Diagnostic Radiology/Nuclear Medicine, University of Western Ontario, London, Canada
| | | | | | | | | | | |
Collapse
|
41
|
Tawarahara K, Kurata C, Taguchi T, Kobayashi A, Yamazaki N. Exercise testing and thallium-201 emission computed tomography in patients with intraventricular conduction disturbances. Am J Cardiol 1992; 69:97-102. [PMID: 1729874 DOI: 10.1016/0002-9149(92)90682-o] [Citation(s) in RCA: 31] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
The specificity of exercise thallium-201 emission computed tomography for coronary artery disease was assessed in patients with intraventricular conduction disturbances. Eighty-seven patients were studied: 33 with right bundle branch block (RBBB), 11 with RBBB and left-axis deviation, 11 with left (L)BBB, 12 on right ventricular pacing, and 20 with Wolff-Parkinson-White (WPW) syndrome. A control group of 349 consecutive patients with normal intraventricular conduction was also examined. The specificity of diagnosis of coronary artery disease in patients with LBBB (30%), right ventricular pacing (44%) or RBBB plus left-axis deviation (50%) was significantly lower than in patients with normal intraventricular conduction (94%; p less than 0.01). In contrast, there was no significant difference between specificity in patients with RBBB (86%) or WPW syndrome (90%) and patients with normal intraventricular conduction. Perfusion defects were found in the anterior, septal and inferior segments in patients with LBBB, and in the septal and inferior segments in patients with RBBB plus left-axis deviation despite the absence of coronary stenosis. Furthermore, diffuse slow washout was seen more often in patients with WPW syndrome (35%) than in controls who had normal intraventricular conduction (11%; p less than 0.05), despite a good exercise performance in the former group. This study suggests that there is an increased incidence of abnormal perfusion and clearance during exercise thallium-201 emission computed tomography in patients with intraventricular conduction disturbances.
Collapse
Affiliation(s)
- K Tawarahara
- Third Department of Internal Medicine, Hamamatsu University School of Medicine, Japan
| | | | | | | | | |
Collapse
|
42
|
Chikamori T, Doi YL, Yonezawa Y, Yamada M, Seo H, Ozawa T. Noninvasive identification of significant narrowing of the left main coronary artery by dipyridamole thallium scintigraphy. Am J Cardiol 1991; 68:472-7. [PMID: 1872274 DOI: 10.1016/0002-9149(91)90781-f] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
To evaluate the usefulness of dipyridamole thallium scintigraphy with low-level exercise for the identification of left main (LM) coronary artery disease (CAD), 466 consecutive patients with CAD were studied. Thirty-eight patients (8%) had LM stenosis (diameter narrowing greater than or equal to 50%). The LM scintigraphic pattern was present in 9 of 38 patients with LMCAD and 38 of 428 CAD patients without LMCAD (24 vs 9%; p less than 0.005). This pattern was present in 6 of 9 patients with LMCAD without right CAD and in only 3 of 29 patients with LM and right CAD (67 vs 10%; p = 0.0005). Patients with LMCAD had a higher incidence of premature cessation of low-level exercise (53 vs 21%; p less than 0.0001), chest pain (68 vs 48%; p less than 0.02), blood pressure decrease of greater than or equal to 20 mm Hg (44 vs 16%; p less than 0.002) and greater ST depression (0.17 +/- 0.13 vs 0.06 +/- 0.10 mV; p less than 0.001) during dipyridamole loading than patients without LMCAD. Stepwise discriminant analysis revealed that the LM scintigraphic pattern and markers of ischemia during dipyridamole loading best identified (p less than 0.0001) patients with LMCAD without right CAD (sensitivity 67%, specificity 91%), but this predictability is no better than the LM scintigraphic pattern alone. The combination of clinical markers of ischemia during dipyridamole loading and scintigraphic findings of diffuse slow washout, extensive fixed defects and the LM pattern best identified (p less than 0.0001) patients with LM and right CAD (sensitivity 72%, specificity 80%).(ABSTRACT TRUNCATED AT 250 WORDS)
Collapse
Affiliation(s)
- T Chikamori
- Department of Medicine and Geriatrics, Kochi Medical School, Japan
| | | | | | | | | | | |
Collapse
|
43
|
Affiliation(s)
- G A Beller
- Division of Cardiology, University of Virginia Health Sciences Center, Charlottesville
| |
Collapse
|
44
|
Takeishi Y, Tono-oka I, Ikeda K, Komatani A, Tsuiki K, Yasui S. Dilatation of the left ventricular cavity on dipyridamole thallium-201 imaging: a new marker of triple-vessel disease. Am Heart J 1991; 121:466-75. [PMID: 1990750 DOI: 10.1016/0002-8703(91)90713-r] [Citation(s) in RCA: 41] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
To investigate the significance and mechanism of dilatation of the left ventricular cavity on dipyridamole thallium-201 imaging, we performed both dipyridamole thallium-201 imaging and dipyridamole radionuclide angiography on 83 patients with known angiograms. The dipyridamole/delayed ratio of the left ventricular dimension from the thallium-201 image was defined as the left ventricular dilatation ratio (LVDR). An LVDR greater than the mean + two standard deviations in patients without coronary artery disease was defined as abnormal. Twenty-two of 83 patients showed an abnormal LVDR, and 18 of the 22 patients (82%) had triple-vessel disease. By defect and washout analysis, the sensitivity and specificity for correctly identifying the patients as having triple-vessel disease was 72% and 76%, respectively, whereas LVDR had a sensitivity of 72% and a specificity of 93%. When LVDR was used in combination with the defect and washout criteria, sensitivity increased to 84% without a loss of specificity. In those 22 patients with abnormal LVDRs, end-diastolic volume measured by radionuclide angiography did not change after dipyridamole infusion. Dilatation of the left ventricular cavity on dipyridamole thallium-201 imaging reflected relative subendocardial hypoperfusion induced by dipyridamole rather than actual chamber enlargement. The LVDR was moderately sensitive and highly specific for triple-vessel disease and provided complementary information to dipyridamole thallium-201 imaging.
Collapse
Affiliation(s)
- Y Takeishi
- First Department of Internal Medicine, Yamagata University School of Medicine, Japan
| | | | | | | | | | | |
Collapse
|
45
|
Hung GL, Siegel ME, McKay C, Chen DC, Ansari AN, Arnstein NB, Lee KH, Stewart CA, Rahimtoola SH. Circumferential quantitative analysis of planar 201T1 myocardial scintigraphy in the diagnosis of coronary artery disease. Angiology 1990; 41:901-7. [PMID: 2244693 DOI: 10.1177/000331979004101102] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
Methodology for the computer analysis of 201T1 myocardial perfusion images has been developed by several laboratories. Substantial evidence of the advantage of this approach over visual inspection alone has been reported. The currently available computer analyses use different algorithms to analyze 201T1 kinetics in the myocardium. The authors evaluated and compared two widely used software programs, Medical Data System (MDS): a mean-count profile, and the Cedars Sinai (CS): a maximal-count profile, of planar 201T1 scintigraphy for their ability to detect coronary artery disease (CAD).
Collapse
Affiliation(s)
- G L Hung
- Department of Radiology, University of Southern California School of Medicine, LAC/USC Medical Center
| | | | | | | | | | | | | | | | | |
Collapse
|
46
|
Maddahi J, Van Train K, Prigent F, Garcia EV, Friedman J, Ostrzega E, Berman D. Quantitative single photon emission computed thallium-201 tomography for detection and localization of coronary artery disease: optimization and prospective validation of a new technique. J Am Coll Cardiol 1989; 14:1689-99. [PMID: 2584558 DOI: 10.1016/0735-1097(89)90017-x] [Citation(s) in RCA: 128] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Abstract
One hundred eight-three men underwent stress-redistribution thallium-201 myocardial perfusion tomography. After evaluation of various preprocessing filters in a phantom study, the Butterworth filter with a frequency cutoff of 0.2 cycles/pixel, order 5 (which provided optimal filter power) was used in the back projection algorithm of the patient studies. All short-axis and apical portions of vertical long-axis images were quantified by dividing each myocardial slice into 60 equal sectors and displaying the maximal count per sector as a linear profile. In a pilot group consisting of 20 normal men (less than 5% likelihood of coronary artery disease) and 25 men with coronary artery disease (greater than or equal to 50% coronary stenosis by angiography), profiles representing the lowest observed value below the mean normal profiles provided the best threshold for defining normal limits. Abnormal portions of the patient profiles were plotted on a two-dimensional polar map. The polar map was divided into 102 sectors, and sectors with a probability of greater than or equal to 80% for disease of each one of the three major coronary arteries were clustered to represent specific coronary artery territories. Receiver operating characteristic curve analysis for defect size showed that the optimal threshold for defining a definite perfusion defect was 12% for the left anterior descending and left circumflex and 8% for the right coronary artery territories. These criteria were prospectively applied to an additional 92 patients with angiographic coronary artery disease, 18 patients with normal coronary arteriograms and 28 patients with less than 5% likelihood of coronary disease. Sensitivity, specificity (in patients with normal coronary arteriograms) and normalcy rate (in patients with less than 5% likelihood of coronary artery disease) for overall detection of coronary disease were 96%, 56% and 86%, respectively. Sensitivity and specificity for identification of individual diseased vessels were, respectively, 78% and 85% for the left anterior descending, 79% and 60% for the left circumflex and 81% and 71% for the right coronary artery. These results were not significantly different from those of the pilot group. An optimized quantitative method for interpretation of stress thallium-201 myocardial perfusion tomography has been developed. Prospective application of this method indicates that the technique is accurate for the overall detection of coronary artery disease and identification of disease in individual arteries.
Collapse
Affiliation(s)
- J Maddahi
- Department of Medicine, Cedars-Sinai Medical Center, Los Angeles, California
| | | | | | | | | | | | | |
Collapse
|
47
|
Becker LC, Rogers WJ, Links JM, Corn C. Limitations of regional myocardial thallium clearance for identification of disease in individual coronary arteries. J Am Coll Cardiol 1989; 14:1491-500. [PMID: 2809009 DOI: 10.1016/0735-1097(89)90387-2] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
The purpose of this study was to critically evaluate the usefulness of postexercise regional myocardial thallium-201 clearance for identifying disease in individual coronary arteries. Exercise and redistribution planar imaging studies were performed in 114 subjects, including 19 normal volunteers and 95 patients undergoing cardiac catheterization (70 with and 25 without greater than or equal to 50% narrowing in one or more coronary arteries). Thallium clearance was measured from predefined myocardial regions corresponding to the left anterior descending, left circumflex and right coronary arteries and was expressed as the percent decrease in activity at 4 h, assuming monoexponential clearance. In regions perfused by a normal or insignificantly diseased coronary artery, mean 4 h clearance was 58.9 +/- 9.4% for normal volunteers, 43.1 +/- 15.5% for catheterized patients without coronary artery disease and 36.3 +/- 24.9% for catheterized patients with coronary artery disease (p less than 0.001 patients with coronary artery disease versus normal volunteers). Clearance from normal regions was significantly associated with two measures of exercise performance: percent of predicted maximal heart rate achieved (r = 0.49) and exercise duration (r = 0.35). In regions perfused by a stenotic coronary artery, mean clearance was lower (31.1 +/- 19.8%) but was not significantly different from that in normal regions in the same patients. Clearance from diseased regions was also associated with maximal exercise heart rate (r = 0.28) and exercise duration (r = 0.41), but not with percent coronary artery stenosis (r = 0.02). After taking exercise performance into account, the number of diseased vessels or the presence or absence of disease in a given vessel had little influence on regional thallium clearance. Although measurement of regional post-exercise thallium clearance may help to identify stenotic coronary arteries in selected patients, variability related to exercise performance and other physiologic and technical factors greatly limits the clinical usefulness of absolute thallium clearance measurements.
Collapse
Affiliation(s)
- L C Becker
- Department of Medicine, Johns Hopkins Medical Institutions, Baltimore, Maryland 21205
| | | | | | | |
Collapse
|
48
|
Fridrich L. Myocardial 201Tl washout after combined dipyridamole submaximal exercise stress: reference values from different patient groups. EUROPEAN JOURNAL OF NUCLEAR MEDICINE 1989; 15:81-6. [PMID: 2920742 DOI: 10.1007/bf00702624] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
Abstract
Dipyridamole stress is favorable in patients unable to exercise maximally for 201Tl myocardial scintigraphy. Aside from an analysis of uptake defects, proper washout analysis can be limited by heart rate variations when isolated dipyridamole stress is used. Heart rate standardized 201Tl washout kinetics after a combined dipyridamole and submaximal exercise stress protocol (CDSE), feasible in elderly patients as well as in patients with peripheral artery disease, were therefore studied to investigate the 201Tl washout after CDSE in differently defined patient groups: Group I comprised 19 patients with documented heart disease and angiographically excluded coronary artery disease (CAD); group II contained 17 patients with a very low likelihood of CAD determined by both normal exercise radionuclide ventriculography and normal 201Tl uptake. Group III comprised 56 patients with a 50% pretest likelihood of CAD but normal 201Tl uptake. Mean washout values were nearly identical in all groups. Despite similar uptake patterns, however, washout standardized by CDSE was significantly lower than the normal washout values after maximal treadmill exercise. Thus an obviously lower 201Tl washout after CDSE than after maximal treadmill exercise must be considered if washout analysis criteria after dipyridamole are applied to evaluate ischemic heart disease. Nevertheless, heart rate elevation achieved by additional submaximal exercise stress seems necessary, adequate and clinically safe for standardisation of washout analysis in dipyridamole 201Tl scintigraphy.
Collapse
Affiliation(s)
- L Fridrich
- Cardiac Rehabilitation Center Hochegg, Grimmenstein, Austria
| |
Collapse
|
49
|
Reed DC, Beller GA, Nygaard TW, Tedesco C, Watson DD, Burwell LR. The clinical efficacy and scintigraphic evaluation of post-coronary bypass patients undergoing percutaneous transluminal coronary angioplasty for recurrent angina pectoris. Am Heart J 1989; 117:60-71. [PMID: 2521419 DOI: 10.1016/0002-8703(89)90657-1] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Abstract
The efficacy of percutaneous transluminal angioplasty in improving recurrent anginal symptoms and myocardial perfusion after coronary artery bypass graft surgery was assessed prospectively in 55 patients, of whom 50 had an initial angiographic and clinical success. Although 80% of those successfully dilated were initially free of angina at 23 +/- 11 months of follow-up, one half of these patients had recurrent angina. Although only 48% of the patient cohort had complete relief of angina, 94% had less angina than before dilatation and 86% were able to decrease antianginal medications. Fifteen patients with persistent or recurrent angina had from one to five repeat dilatations. After angioplasty, lung thallium uptake, the extent of abnormal scan segments, and the magnitude of redistribution in dilated lesions were significantly reduced (n = 24 patients). Redistribution defects were seen in 38% of patients on postangioplasty scans. All were associated with subsequent angina. Of various clinical, angiographic, exercise, and thallium-201 scan variables, only the presence of delayed redistribution was an independent predictor of recurrent angina. Restenosis was the most common underlying cause for this exercise-induced perfusion defect. Thus percutaneous coronary angioplasty performed as primary therapy for recurrent angina after bypass surgery is moderately successful in long-term follow-up for the amelioration of symptoms and enhancement of regional myocardial perfusion.
Collapse
Affiliation(s)
- D C Reed
- Department of Internal Medicine, University of Virginia Medical Center, Charlottesville 22908
| | | | | | | | | | | |
Collapse
|
50
|
Abstract
Ambulatory (Holter) electrocardiography has evolved over the past two decades to allow accurate assessment of the cardiac rhythm, and more recently, accurate detection and measurement of ST segment changes. These ambulatory ECG ST segment changes that occur with and without symptoms, although thought to be of questionable clinical value for many years, have recently been clearly documented in coronary artery disease patients to represent true myocardial ischemia. Concurrent with these technologic developments has been an evolution of the pathophysiologic understanding of myocardial ischemia, and the relative role and sequential nature that ECG ST segment changes have in its development. This review examines from a clinical perspective the current understanding of the pathophysiologic sequence of development of myocardial ischemia, emphasizes the ECG diagnostic methods that detect this sequential change, examines the criteria that define ambulatory ECG myocardial ischemia, and discusses those nonischemic factors that affect the ECG ST segment and its interpretation. Moreover, an ever increasing number of ambulatory ECG studies of coronary artery disease and normal patients have defined unique characteristics of the ambulatory ECG ST segment changes observed with regard to its diagnostic, prognostic, and therapeutic assessment value in the study of myocardial ischemia.
Collapse
Affiliation(s)
- H L Kennedy
- Department of Internal Medicine, St. Louis University School of Medicine, MO
| | | |
Collapse
|