1
|
Zhang H, Jia H, Hong J, Zhang M, Jiang T, Xu W. Development of a High-Field "Brick" Mass Spectrometer with Extended Mass Range and Capable of Characterizing Native Proteins. Anal Chem 2023; 95:13503-13508. [PMID: 37650728 DOI: 10.1021/acs.analchem.3c01769] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/01/2023]
Abstract
One of the main challenges of analyzing intact proteins on an ion trap mass spectrometer is the mass range limitation, especially for miniature mass spectrometers. In this study, a high-field frequency scanning ion trap miniature mass spectrometer, namely the high-field "Brick" mass spectrometer, was developed to analyze intact proteins. A high-voltage broadband radio frequency (rf) amplifier was designed with a maximum output of 900 Vp-p over a frequency range of 130-700 kHz. Compared to the 600 Vp-p rf amplifier equipped in the conventional "Brick" mass spectrometer, the mass range of the instrument could be extended from 2000 to over 8000 Th. Sensitivity and mass resolution for native protein analyses were also evaluated and compared. Various proteins as well as their mixtures were analyzed on the high-field "Brick" mass spectrometer. The noncovalent interaction between protein-ligand complexes, lysozyme with triN-acetylchitotriose, was also analyzed. In addition, a hybrid ion scan mode was explored to further expand the mass range of the instrument at both low- and high-mass ends. In the hybrid ion scan mode, both rf frequency and amplitude were tuned, and a mass range from 100 to 12,000 Th was realized. As a result, both small drugs and proteins could be analyzed in a single mass scan. As proof-of-concept demonstrations, a mixture of atenolol and bovine serum albuminand oligomers of transferrin were analyzed.
Collapse
Affiliation(s)
- Hongjia Zhang
- School of Medical Technology, Beijing Institute of Technology, Beijing 100081, China
| | - Heyuan Jia
- Kunshan Nier Precision Instrumentation Inc., Kunshan, Suzhou 215316, China
| | - Jie Hong
- School of Medical Technology, Beijing Institute of Technology, Beijing 100081, China
| | - Mei Zhang
- School of Chinese Materia Medica, Beijing University of Chinese Medicine, Beijing 102488, China
| | - Ting Jiang
- School of Medical Technology, Beijing Institute of Technology, Beijing 100081, China
| | - Wei Xu
- School of Medical Technology, Beijing Institute of Technology, Beijing 100081, China
| |
Collapse
|
2
|
Patil AA, Liu ZX, Chiu YP, Lại TKL, Chou SW, Cheng CY, Su WM, Liao HT, Agcaoili JBA, Peng WP. Development of a linear ion trap mass spectrometer capable of analyzing megadalton MALDI ions. Talanta 2023; 259:124555. [PMID: 37088041 DOI: 10.1016/j.talanta.2023.124555] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2023] [Revised: 04/02/2023] [Accepted: 04/11/2023] [Indexed: 04/25/2023]
Abstract
Detecting megadalton matrix-assisted laser desorption/ionization (MALDI) ions in an ion trap mass spectrometer is a technical challenge. In this study, megadalton protein and polymer ions were successfully measured by MALDI linear ion trap mass spectrometer (LIT-MS) for the first time. The LIT-MS is comprised of a Thermo linear ion trap mass analyzer and a highly sensitive charge-sensing particle detector (CSPD). A newly designed radio frequency (rf) scan mode with dipolar resonance ejection techniques is proposed to extend the mass range of LIT-MS up to one million Thomson (Th). We analyze high mass ions with mass-to charge (m/z) ratios ranging from 100 kTh to 1 MTh, including thyroglobulin, alpha-2-macroglobulin, immunoglobulins (e.g., IgG and IgM), and polymer (∼ 940 kTh) ions. Besides, it is also very challenging for ion trap mass spectrometry to detect megadalton ions at low concentrations. By adopting high affinity carboxylated/oxidized detonation nanodiamonds (oxDNDs) to enrich IgM molecules and form antibody-nanodiamond conjugates, we have successfully reached ∼ 5 nM (5 μg/mL) concentration which is better than that by the other techniques.
Collapse
Affiliation(s)
- Avinash A Patil
- Department of Physics, National Dong Hwa University, Shoufeng, Hualien, 97401, Taiwan
| | - Zhe-Xuan Liu
- Department of Physics, National Dong Hwa University, Shoufeng, Hualien, 97401, Taiwan
| | - Yi-Pang Chiu
- Department of Physics, National Dong Hwa University, Shoufeng, Hualien, 97401, Taiwan
| | - Thị Khánh Ly Lại
- Department of Physics, National Dong Hwa University, Shoufeng, Hualien, 97401, Taiwan
| | - Szu-Wei Chou
- AcroMass Technologies Inc., Hukou, Hsinchu, 30352, Taiwan
| | - Chun-Yen Cheng
- AcroMass Technologies Inc., Hukou, Hsinchu, 30352, Taiwan
| | - Wen-Min Su
- Department of Life Science, National Dong Hwa University, Hualien, 97401, Taiwan
| | - Hong-Ting Liao
- Department of Life Science, National Dong Hwa University, Hualien, 97401, Taiwan
| | | | - Wen-Ping Peng
- Department of Physics, National Dong Hwa University, Shoufeng, Hualien, 97401, Taiwan.
| |
Collapse
|
3
|
Darie-Ion L, Whitham D, Jayathirtha M, Rai Y, Neagu AN, Darie CC, Petre BA. Applications of MALDI-MS/MS-Based Proteomics in Biomedical Research. Molecules 2022; 27:6196. [PMID: 36234736 PMCID: PMC9570737 DOI: 10.3390/molecules27196196] [Citation(s) in RCA: 20] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2022] [Revised: 09/14/2022] [Accepted: 09/15/2022] [Indexed: 11/22/2022] Open
Abstract
Matrix-assisted laser desorption/ionization (MALDI) mass spectrometry (MS) is one of the most widely used techniques in proteomics to achieve structural identification and characterization of proteins and peptides, including their variety of proteoforms due to post-translational modifications (PTMs) or protein-protein interactions (PPIs). MALDI-MS and MALDI tandem mass spectrometry (MS/MS) have been developed as analytical techniques to study small and large molecules, offering picomole to femtomole sensitivity and enabling the direct analysis of biological samples, such as biofluids, solid tissues, tissue/cell homogenates, and cell culture lysates, with a minimized procedure of sample preparation. In the last decades, structural identification of peptides and proteins achieved by MALDI-MS/MS helped researchers and clinicians to decipher molecular function, biological process, cellular component, and related pathways of the gene products as well as their involvement in pathogenesis of diseases. In this review, we highlight the applications of MALDI ionization source and tandem approaches for MS for analyzing biomedical relevant peptides and proteins. Furthermore, one of the most relevant applications of MALDI-MS/MS is to provide "molecular pictures", which offer in situ information about molecular weight proteins without labeling of potential targets. Histology-directed MALDI-mass spectrometry imaging (MSI) uses MALDI-ToF/ToF or other MALDI tandem mass spectrometers for accurate sequence analysis of peptide biomarkers and biological active compounds directly in tissues, to assure complementary and essential spatial data compared with those obtained by LC-ESI-MS/MS technique.
Collapse
Affiliation(s)
- Laura Darie-Ion
- Laboratory of Biochemistry, Department of Chemistry, “Alexandru Ioan Cuza” University of Iasi, Carol I bvd, No. 11, 700506 Iasi, Romania
| | - Danielle Whitham
- Biochemistry & Proteomics Laboratories, Department of Chemistry and Biomolecular Science, Clarkson University, 8 Clarkson Avenue, Potsdam, NY 13699, USA
| | - Madhuri Jayathirtha
- Biochemistry & Proteomics Laboratories, Department of Chemistry and Biomolecular Science, Clarkson University, 8 Clarkson Avenue, Potsdam, NY 13699, USA
| | - Yashveen Rai
- Biochemistry & Proteomics Laboratories, Department of Chemistry and Biomolecular Science, Clarkson University, 8 Clarkson Avenue, Potsdam, NY 13699, USA
| | - Anca-Narcisa Neagu
- Laboratory of Animal Histology, Faculty of Biology, “Alexandru Ioan Cuza” University of Iasi, Carol I bvd, No. 22, 700505 Iasi, Romania
| | - Costel C. Darie
- Biochemistry & Proteomics Laboratories, Department of Chemistry and Biomolecular Science, Clarkson University, 8 Clarkson Avenue, Potsdam, NY 13699, USA
| | - Brînduşa Alina Petre
- Laboratory of Biochemistry, Department of Chemistry, “Alexandru Ioan Cuza” University of Iasi, Carol I bvd, No. 11, 700506 Iasi, Romania
- Biochemistry & Proteomics Laboratories, Department of Chemistry and Biomolecular Science, Clarkson University, 8 Clarkson Avenue, Potsdam, NY 13699, USA
- Center for Fundamental Research and Experimental Development in Translation Medicine–TRANSCEND, Regional Institute of Oncology, 700483 Iasi, Romania
| |
Collapse
|
4
|
Lin JL, Chu ML, Chen CH. A portable multiple ionization source biological mass spectrometer. Analyst 2020; 145:3495-3504. [PMID: 32186555 DOI: 10.1039/d0an00126k] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
In the past, matrix-assisted laser desorption/ionization (MALDI) and electrospray ionization (ESI), used for large biomolecule detection, were usually installed in two separate mass spectrometers. In this study, they were equipped in the same mass spectrometer. This portable biological mass spectrometer has multiple ionization capabilities in the same mass spectrometer and shares the same mass analyzer and detector. This mass spectrometer can be operated under low vacuum (∼10-3 Torr) and can use air as the buffer gas. Therefore, the demand for pumping is reduced and rare gas feeding is no longer essential. A small scroll pump, employed to assist a miniature turbo pump, is sufficient to maintain the operational pressure. The mass spectra of biomolecules were obtained using frequency scanning instead of voltage ramping. Therefore, a wider mass-to-charge ratio (m/z) range was achieved. Furthermore, the design also couples a conversion dynode with a channeltron to enhance the mass detection range. This homemade mass spectrometer has the capability to measure charged particles with very large m/z values (m/z > 100 000). The concentrations of the studied compounds (angiotensin, insulin, cytochrome C, bovine serum albumin (BSA), immunoglobulin G, and immunoglobulin A) are from 5 femtomole to 100 picomole, and the mass resolutions are from 30 to 260. The mass range of this portable mass spectrometer was comparable with a commercial linear time-of-flight mass spectrometer owing to the use of the frequency scan.
Collapse
Affiliation(s)
- Jung-Lee Lin
- Genomics Research Center, Academia Sinica, Taipei, Taiwan.
| | - Ming-Lee Chu
- Institute of physics, Academia Sinica, Taipei, Taiwan
| | | |
Collapse
|
5
|
Tang Y, Xu Q, Li D, Xu W. A mini mass spectrometer with a low noise Faraday detector. Analyst 2020; 145:3892-3898. [DOI: 10.1039/d0an00420k] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
A low noise Faraday detector and a data processing method were developed for a miniature ion trap mass spectrometer.
Collapse
Affiliation(s)
- Yang Tang
- School of Life Science
- Beijing Institute of Technology
- Beijing 100081
- China
| | - Qian Xu
- School of Life Science
- Beijing Institute of Technology
- Beijing 100081
- China
| | - Dayu Li
- School of Computer Science and Engineering
- Northeastern University
- Shenyang 110819
- China
| | - Wei Xu
- School of Life Science
- Beijing Institute of Technology
- Beijing 100081
- China
| |
Collapse
|
6
|
Biomolecular Clusters Distribution up to Mega Dalton Region Using MALDI-Quadrupole Ion Trap Mass Spectrometer. Int J Mol Sci 2018; 19:ijms19092789. [PMID: 30227603 PMCID: PMC6164314 DOI: 10.3390/ijms19092789] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2018] [Revised: 09/01/2018] [Accepted: 09/14/2018] [Indexed: 11/17/2022] Open
Abstract
We present the first report on complete cluster distributions of cytochrome c (molecular weight of 12.4 kDa) and bovine serum albumin ((BSA), molecular weight of 66.4 kDa) with mass-to-charge ratio (m/z) reaching 350,000 and 1,400,000, respectively, by matrix-assisted laser desorption/ionization (MALDI). Large cluster distributions of the analytes were measured by our homemade frequency-scanned quadrupole ion trap (QIT) mass spectrometer with a charge detector. To our knowledge, we report the highest m/z clusters of these two biomolecules. The quantitative results indicate that large clusters ions of cytochrome c and BSA follow the power law (r2 > 0.99) with cluster size distribution, which provides experimental evidence for the laser ablation studies of MALDI.
Collapse
|
7
|
Patil AA, Chou SW, Chang PY, Lee CW, Cheng CY, Chu ML, Peng WP. High Mass Ion Detection with Charge Detector Coupled to Rectilinear Ion Trap Mass Spectrometer. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2017; 28:1066-1078. [PMID: 27966174 DOI: 10.1007/s13361-016-1548-0] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/09/2016] [Revised: 10/25/2016] [Accepted: 10/28/2016] [Indexed: 06/06/2023]
Abstract
Conventional linear ion trap mass analyzers (LIT-MS) provide high ion capacity and show their MS n ability; however, the detection of high mass ions is still challenging because LIT-MS with secondary electron detectors (SED) cannot detect high mass ions. To detect high mass ions, we coupled a charge detector (CD) to a rectilinear ion trap mass spectrometer (RIT-MS). Immunoglobulin G ions (m/z ~150,000) are measured successfully with controlled ion kinetic energy. In addition, when mass-to-charge (m/z) ratios of singly charged ions exceed 10 kTh, the detection efficiency of CD is found to be greater than that of SED. The CD can be coupled to LIT-MS to extend the detection mass range and provide the potential to perform MS n of high mass ions inside the ion trap. Graphical Abstract ᅟ.
Collapse
Affiliation(s)
- Avinash A Patil
- Department of Physics, National Dong Hwa University, Shoufeng, Hualien, Taiwan, 97401, Republic of China
| | - Szu-Wei Chou
- Department of Physics, National Dong Hwa University, Shoufeng, Hualien, Taiwan, 97401, Republic of China
- AcroMass technologies Inc., Hukou, Hsinchu, Taiwan, 30352, Republic of China
| | - Pei-Yu Chang
- Department of Physics, National Dong Hwa University, Shoufeng, Hualien, Taiwan, 97401, Republic of China
| | - Chen-Wei Lee
- Department of Physics, National Dong Hwa University, Shoufeng, Hualien, Taiwan, 97401, Republic of China
| | - Chun-Yen Cheng
- AcroMass technologies Inc., Hukou, Hsinchu, Taiwan, 30352, Republic of China
| | - Ming-Lee Chu
- Institute of Physics, Academia Sinica, Taipei, Taiwan, Republic of China
| | - Wen-Ping Peng
- Department of Physics, National Dong Hwa University, Shoufeng, Hualien, Taiwan, 97401, Republic of China.
| |
Collapse
|
8
|
Harvey DJ. Analysis of carbohydrates and glycoconjugates by matrix-assisted laser desorption/ionization mass spectrometry: An update for 2011-2012. MASS SPECTROMETRY REVIEWS 2017; 36:255-422. [PMID: 26270629 DOI: 10.1002/mas.21471] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/19/2014] [Accepted: 01/15/2015] [Indexed: 06/04/2023]
Abstract
This review is the seventh update of the original article published in 1999 on the application of MALDI mass spectrometry to the analysis of carbohydrates and glycoconjugates and brings coverage of the literature to the end of 2012. General aspects such as theory of the MALDI process, matrices, derivatization, MALDI imaging, and fragmentation are covered in the first part of the review and applications to various structural types constitute the remainder. The main groups of compound are oligo- and poly-saccharides, glycoproteins, glycolipids, glycosides, and biopharmaceuticals. Much of this material is presented in tabular form. Also discussed are medical and industrial applications of the technique, studies of enzyme reactions, and applications to chemical synthesis. © 2015 Wiley Periodicals, Inc. Mass Spec Rev 36:255-422, 2017.
Collapse
Affiliation(s)
- David J Harvey
- Department of Biochemistry, Oxford Glycobiology Institute, University of Oxford, Oxford, OX1 3QU, UK
| |
Collapse
|
9
|
|
10
|
Snyder DT, Pulliam CJ, Cooks RG. Linear mass scans in quadrupole ion traps using the inverse Mathieu q scan. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2016; 30:2369-2378. [PMID: 27496220 DOI: 10.1002/rcm.7710] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/14/2016] [Revised: 08/01/2016] [Accepted: 08/01/2016] [Indexed: 06/06/2023]
Abstract
RATIONALE Secular frequency scanning is a method of mass selectively scanning ions out of a quadrupole ion trap by linearly ramping the frequency of the resonance ejection signal through ion secular frequencies at constant rf amplitude and frequency. The method is electronically much simpler than resonance ejection but it requires a complex nonlinear calibration procedure to correlate mass-to-charge with time. METHODS A method of secular frequency scanning in quadrupole ion traps is described in which mass-to-charge is linear with time. This method, termed an "inverse Mathieu q scan", contrasts with linear frequency sweeping which requires a complex nonlinear mass calibration procedure. In the current method, mass scans are forced to be linear with time by scanning the frequency of the supplementary ac so that there is an inverse relationship between the ejected ion's Mathieu q parameter and time. RESULTS In all cases, excellent mass spectral linearity is observed. The rf amplitude is shown to control both the scan range and the scan rate, whereas the ac amplitude and scan rate influence the mass resolution. The scan rate depends linearly on the rf amplitude, a unique feature of this scan. Although changes in either rf or ac amplitude affect the positions of peaks in time, they do not change the mass calibration procedure since this only requires a simple linear fit of m/z vs time. Space charge effects are shown to give rise to significant changes in resolution as well as to mass shifts. CONCLUSIONS A method of secular frequency scanning which provides a linear mass scale has been demonstrated. The inverse Mathieu q scan offers a significant increase in mass range and power savings while maintaining access to linearity, paving the way for a mass spectrometer based completely on ac waveforms for ion isolation, ion activation, and ion ejection. Copyright © 2016 John Wiley & Sons, Ltd.
Collapse
Affiliation(s)
- Dalton T Snyder
- Department of Chemistry and Center for Analytical Instrumentation Development, Purdue University, West Lafayette, IN, 47907, USA
| | - Christopher J Pulliam
- Department of Chemistry and Center for Analytical Instrumentation Development, Purdue University, West Lafayette, IN, 47907, USA
| | - R Graham Cooks
- Department of Chemistry and Center for Analytical Instrumentation Development, Purdue University, West Lafayette, IN, 47907, USA.
| |
Collapse
|
11
|
Peng WP, Chou SW, Patil AA. Measuring masses of large biomolecules and bioparticles using mass spectrometric techniques. Analyst 2014; 139:3507-23. [DOI: 10.1039/c3an02329j] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Mass spectrometric techniques can measure the masses and fragments of large biomolecules and bioparticles.
Collapse
Affiliation(s)
- Wen-Ping Peng
- Department of Physics
- National Dong Hwa University
- Hualien, Republic of China
| | - Szu-Wei Chou
- Department of Physics
- National Dong Hwa University
- Hualien, Republic of China
| | - Avinash A. Patil
- Department of Physics
- National Dong Hwa University
- Hualien, Republic of China
| |
Collapse
|
12
|
Hsu YF, Lin JL, Chu ML, Wang YS, Chen CH. Macromolecular ion accelerator mass spectrometer. Analyst 2013; 138:7384-91. [DOI: 10.1039/c3an01534c] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|