1
|
Pukleš I, Páger C, Sakač N, Šarkanj B, Matasović B, Samardžić M, Budetić M, Marković D, Jozanović M. Electrophoretic Determination of L-Carnosine in Health Supplements Using an Integrated Lab-on-a-Chip Platform with Contactless Conductivity Detection. Int J Mol Sci 2023; 24:14705. [PMID: 37834151 PMCID: PMC10572305 DOI: 10.3390/ijms241914705] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2023] [Revised: 09/22/2023] [Accepted: 09/27/2023] [Indexed: 10/15/2023] Open
Abstract
The health supplement industry is one of the fastest growing industries in the world, but there is a lack of suitable analytical methods for the determination of active compounds in health supplements such as peptides. The present work describes an implementation of contactless conductivity detection on microchip technology as a new strategy for the electrophoretic determination of L-carnosine in complex health supplement formulations without pre-concentration and derivatization steps. The best results were obtained in the case of +1.00 kV applied for 20 s for injection and +2.75 kV applied for 260 s for the separation step. Under the selected conditions, a linear detector response of 5 × 10-6 to 5 × 10-5 M was achieved. L-carnosine retention time was 61 s. The excellent reproducibility of both migration time and detector response confirmed the high precision of the method. The applicability of the method was demonstrated by the determination of L-carnosine in three different samples of health supplements. The recoveries ranged from 91 to 105%. Subsequent analysis of the samples by CE-UV-VIS and HPLC-DAD confirmed the accuracy of the obtained results.
Collapse
Affiliation(s)
- Iva Pukleš
- Department of Chemistry, Josip Juraj Strossmayer University of Osijek, Cara Hadrijana 8, 31000 Osijek, Croatia; (I.P.); (B.M.); (M.S.); (M.B.)
- Doctoral School of Chemistry, University of Pécs, Ifjúság útja, 7624 Pécs, Hungary
- Department of Analytical and Environmental Chemistry, Faculty of Sciences, University of Pécs, Ifjúság Útja, 7624 Pécs, Hungary
| | - Csilla Páger
- Institute of Bioanalysis, Medical School, Szentágothai Research Center, University of Pécs, Honvéd Utca 1, 7624 Pécs, Hungary;
| | - Nikola Sakač
- Faculty of Geotechnical Engineering, University of Zagreb, Hallerova 7, 42000 Varaždin, Croatia
| | - Bojan Šarkanj
- Department of Food Technology, University North, Trg dr. Žarka Dolinara 1, 48000 Koprivnica, Croatia;
| | - Brunislav Matasović
- Department of Chemistry, Josip Juraj Strossmayer University of Osijek, Cara Hadrijana 8, 31000 Osijek, Croatia; (I.P.); (B.M.); (M.S.); (M.B.)
| | - Mirela Samardžić
- Department of Chemistry, Josip Juraj Strossmayer University of Osijek, Cara Hadrijana 8, 31000 Osijek, Croatia; (I.P.); (B.M.); (M.S.); (M.B.)
- Scientific Center of Excellence for Personalized Health Care, Josip Juraj Strossmayer University of Osijek, Trg Svetog Trojstva 3, 31000 Osijek, Croatia
| | - Mateja Budetić
- Department of Chemistry, Josip Juraj Strossmayer University of Osijek, Cara Hadrijana 8, 31000 Osijek, Croatia; (I.P.); (B.M.); (M.S.); (M.B.)
- Scientific Center of Excellence for Personalized Health Care, Josip Juraj Strossmayer University of Osijek, Trg Svetog Trojstva 3, 31000 Osijek, Croatia
| | - Dean Marković
- Department of Biotechnology, University of Rijeka, Radmile Matejčić 2, 51000 Rijeka, Croatia;
| | - Marija Jozanović
- Department of Chemistry, Josip Juraj Strossmayer University of Osijek, Cara Hadrijana 8, 31000 Osijek, Croatia; (I.P.); (B.M.); (M.S.); (M.B.)
- Doctoral School of Chemistry, University of Pécs, Ifjúság útja, 7624 Pécs, Hungary
- Scientific Center of Excellence for Personalized Health Care, Josip Juraj Strossmayer University of Osijek, Trg Svetog Trojstva 3, 31000 Osijek, Croatia
| |
Collapse
|
2
|
Isoelectric focusing on microfluidic paper-based chips. Anal Bioanal Chem 2019; 411:5415-5422. [DOI: 10.1007/s00216-019-02008-5] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2019] [Revised: 06/24/2019] [Accepted: 06/28/2019] [Indexed: 01/25/2023]
|
3
|
Connector-Free World-to-Chip Interconnection for Microfluidic Devices. MICROMACHINES 2019; 10:mi10030166. [PMID: 30818805 PMCID: PMC6471718 DOI: 10.3390/mi10030166] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/04/2019] [Revised: 02/22/2019] [Accepted: 02/26/2019] [Indexed: 01/16/2023]
Abstract
In the development of functional lab-on-a-chip (LOC), there is a need to produce a reliable and high pressure connection between capillary tubes and microfluidic devices for carrying fluids. The current technologies still have limitations in achieving ideal interconnection since they are bulky, expensive or complicated. In this paper, a novel connector-free technique using an interference fit mechanism is introduced for world-to-chip interconnection. The proposed technique has considerable potential for replacing current interconnection tools for microfluidic devices due to the advantages including no chemical contamination, easy plugging, enough strength to sustain pressure, high density integration, simple and rapid integration.
Collapse
|
4
|
Interfacing microchip isoelectric focusing with on-chip electrospray ionization mass spectrometry. J Chromatogr A 2015; 1398:121-6. [DOI: 10.1016/j.chroma.2015.04.031] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2015] [Revised: 04/14/2015] [Accepted: 04/17/2015] [Indexed: 12/23/2022]
|
5
|
Shimura K, Nagai T. Direct coupling of immobilized metal ion affinity chromatography and capillary isoelectric focusing in a single capillary. ACTA ACUST UNITED AC 2015. [DOI: 10.2198/jelectroph.59.7] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Affiliation(s)
- Kiyohito Shimura
- Division of Advanced Chemistry, School of Medicine, Fukushima Medical University
| | - Toshihiko Nagai
- Division of Advanced Chemistry, School of Medicine, Fukushima Medical University
| |
Collapse
|
6
|
Recent developments in microfluidic chip-based separation devices coupled to MS for bioanalysis. Bioanalysis 2013; 5:2567-80. [DOI: 10.4155/bio.13.196] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2023] Open
Abstract
In recent years, the development of microfluidic chip separation devices coupled to MS has dramatically increased for high-throughput bioanalysis. In this review, advances in different types of microfluidic chip separation devices, such as electrophoresis- and LC-based microchips, as well as 2D design of microfluidic chip-based separation devices will be discussed. In addition, the utilization of chip-based separation devices coupled to MS for analyzing peptides/proteins, glycans, drug metabolites and biomarkers for various bioanalytical applications will be evaluated.
Collapse
|
7
|
Stoyanov A. IEF-based multidimensional applications in proteomics: Toward higher resolution. Electrophoresis 2012; 33:3281-90. [DOI: 10.1002/elps.201200221] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2012] [Revised: 08/20/2012] [Accepted: 08/21/2012] [Indexed: 01/08/2023]
Affiliation(s)
- Alexander Stoyanov
- Department of Pathology and Anatomical Sciences; University of Missouri; Columbia; MO; USA
| |
Collapse
|
8
|
Kitagawa F, Kawai T, Sueyoshi K, Otsuka K. Recent progress of on-line sample preconcentration techniques in microchip electrophoresis. ANAL SCI 2012; 28:85-93. [PMID: 22322799 DOI: 10.2116/analsci.28.85] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
This review highlights recent developments and applications of on-line sample preconcentration techniques to enhance the detection sensitivity in microchip electrophoresis (MCE); references are mainly from 2008 and later. Among various developed techniques, we focus on the sample preconcentration based on the changes in the migration velocity of analytes in two or three discontinuous solutions system, since they can provide the sensitivity enhancement with relatively easy experimental procedures and short analysis times. The characteristic features of the on-line sample preconcentration applied to microchip electrophoresis (MCE) are presented, categorized on the basis of "field strength-" or "chemically" induced changes in the migration velocity. The preconcentration techniques utilizing field strength-induced changes in the velocity include field-amplified sample stacking, isotachophoresis and transient-isotachophoresis, whereas those based on chemically induced changes in the velocity are sweeping, transient-trapping and dynamic pH junction.
Collapse
Affiliation(s)
- Fumihiko Kitagawa
- Department of Frontier Materials Chemistry, Graduate School of Science and Technology, Hirosaki University, 3 Bunkyo, Hirosaki, Aomori 036–8561, Japan.
| | | | | | | |
Collapse
|
9
|
Nge PN, Yang W, Pagaduan JV, Woolley AT. Ion-permeable membrane for on-chip preconcentration and separation of cancer marker proteins. Electrophoresis 2011; 32:1133-40. [PMID: 21544838 DOI: 10.1002/elps.201000698] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
Abstract
Cancer marker proteins have been electrophoretically concentrated and then separated in a microfluidic device. On-chip preconcentration was achieved using an ion-permeable membrane, consisting of acrylamide, N,N'-methylene-bisacrylamide and 2-(acrylamido)-2-methylpropanesulfonate. This negatively charged membrane was photopolymerized in the microdevice near the injection intersection. Anionic proteins were excluded from the porous membrane based on both size and charge, which concentrated target components in the injection intersection prior to separation by microchip capillary electrophoresis (μ-CE). Bovine serum albumin was used in the initial characterization of the system and showed a 40-fold enrichment in the μ-CE peak with 4 min of preconcentration. Adjustment of buffer pH enabled baseline resolution of two cancer biomarkers, α-fetoprotein (AFP) and heat shock protein 90 (HSP90), while fine control over preconcentration time limited peak broadening. Our optimized preconcentration and μ-CE approach was applied to AFP and HSP90, where enrichment factors of >10-fold were achieved with just 1 min of preconcentration. Overall, the process was simple and rapid, providing a useful tool for improving detection in microscale systems.
Collapse
Affiliation(s)
- Pamela N Nge
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT 84602, USA
| | | | | | | |
Collapse
|
10
|
Kenyon SM, Meighan MM, Hayes MA. Recent developments in electrophoretic separations on microfluidic devices. Electrophoresis 2011; 32:482-93. [DOI: 10.1002/elps.201000469] [Citation(s) in RCA: 53] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2010] [Revised: 11/24/2010] [Accepted: 12/09/2010] [Indexed: 11/09/2022]
|
11
|
Kataoka M, Yokoyama H, Henares TG, Kawamura K, Yao T, Hisamoto H. Reagent-release capillary array-isoelectric focusing device as a rapid screening device for IEF condition optimization. LAB ON A CHIP 2010; 10:3341-3347. [PMID: 20714639 DOI: 10.1039/c0lc00019a] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/29/2023]
Abstract
This report describes the fabrication and characterization of a simple and disposable capillary isoelectric focusing (cIEF) device containing a reagent-release capillary (RRC) array and poly(dimethylsiloxane) (PDMS) platform, which allows rapid (within 10 min) screening of cIEF conditions by introducing a sample solution into plural RRCs by capillary action followed by electric field application. To prepare the RRC, covalent immobilization of poly(dimethylacrylamide) (PDMA) was conducted to suppress electro-osmotic flow (EOF), followed by physical adsorption of the mixture of carrier ampholyte (CA), surfactant, labeling reagent (LR), and other additives to the PDMA surface to construct a two-layer structure inside a square glass capillary. When the sample solution containing proteins was introduced into the RRC, physically adsorbed CA, surfactant, and LR can be dissolved and released into the sample solution. Then, complexation of LR with proteins, mixing with CA and surfactant, and exposure of the PDMA surface spontaneously occurs for the IEF experiments. Here, three different RRCs that immobilize different CAs were prepared, and simultaneous cIEF experiments involving hemoglobin AFSC mixtures for choosing the best CA demonstrated the proof of concept.
Collapse
Affiliation(s)
- Masaki Kataoka
- Department of Applied Chemistry, Graduate School of Engineering, Osaka Prefecture University, 1-1 Gakuen-cho, Naka-ku, Sakai City, Osaka 599-8531, Japan
| | | | | | | | | | | |
Collapse
|
12
|
Xu Z, Okabe N, Arai A, Hirokawa T. Investigation of the pH gradient formation and cathodic drift in microchip isoelectric focusing with imaged UV detection. Electrophoresis 2010; 31:3558-65. [DOI: 10.1002/elps.201000395] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
|
13
|
KITAGAWA F, AIZAWA S, OTSUKA K. High-speed Analysis of Proteins by Microchip Isoelectric Focusing with Linear-imaging UV Detection. ANAL SCI 2009; 25:979-84. [DOI: 10.2116/analsci.25.979] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
14
|
|