1
|
Liu Q, Xiang R, Zhao Y, Cui L. Exploration of the adsorption and desorption performance of volatile organic compounds by activated carbon with different shapes based on fixed-bed experiments. CHEMOSPHERE 2024; 364:143161. [PMID: 39178967 DOI: 10.1016/j.chemosphere.2024.143161] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/18/2023] [Revised: 07/12/2024] [Accepted: 08/20/2024] [Indexed: 08/26/2024]
Abstract
Activated carbon (AC) has been widely used in volatile organic compounds (VOCs) treatment of industrial exhaust gases. Rather than modifying specific pore size distributions and surface properties, altering the shape of AC offers a more feasible approach to enhance its adsorption performance. This study investigates the adsorption-desorption performance of two different shaped ACs with highly similar properties for the removal of VOCs. The clover-shaped AC (CSAC) has a 27.46% lower internal void fraction and a 39.10% higher external void fraction compared to cylindrical AC (CAC), resulting in denser packing and longer contact time with VOCs. Adsorption experiments showed the CSAC has 40% longer adsorption breakthrough (BT) times for ethanol, ethyl acetate, and n-hexane on average, and 20% higher saturation adsorption capacity per unit volume. CSAC also has higher partition coefficients, with the highest values for ethanol, ethyl acetate, and n-hexane being 0.0187, 0.0382, and 0.0527 mol kg-1·Pa-1, respectively. The desorption process for selected VOCs is non-spontaneous and endothermic. Optimal desorption conditions were identified as an inlet space velocity of 3535 h-1, a desorption temperature of 150 °C, and a pulsed inlet method. To investigate the possibility of the application of CSAC in real-world scenarios, xylene was chosen as a representative industrial VOC. Results showed CSAC has 20% higher BT time and saturation adsorption capacity for xylene compared to CAC under different bed heights. The desorption efficiency for xylene on both ACs is below 40%. With increasing xylene inlet concentration, the mass transfer zone (MTZ) height initially increases but stabilizes beyond 1704 mg m-3. At identical bed heights, the MTZ height of CSAC is 29% shorter than CAC, indicating a higher bed utilization efficiency.
Collapse
Affiliation(s)
- Qin Liu
- Key Laboratory of Resources Conversion and Pollution Control of the State Ethnic Affairs Commission, College of Resources and Environment, South-Central Minzu University, Wuhan, 430074, China
| | - Ruyi Xiang
- Key Laboratory of Resources Conversion and Pollution Control of the State Ethnic Affairs Commission, College of Resources and Environment, South-Central Minzu University, Wuhan, 430074, China
| | - Yufeng Zhao
- Key Laboratory of Resources Conversion and Pollution Control of the State Ethnic Affairs Commission, College of Resources and Environment, South-Central Minzu University, Wuhan, 430074, China.
| | - Longzhe Cui
- Key Laboratory of Resources Conversion and Pollution Control of the State Ethnic Affairs Commission, College of Resources and Environment, South-Central Minzu University, Wuhan, 430074, China.
| |
Collapse
|
2
|
Liu C, Otsuka K, Kawai T. Recent advances in microscale separation techniques for glycome analysis. J Sep Sci 2024; 47:e2400170. [PMID: 38863084 DOI: 10.1002/jssc.202400170] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2024] [Revised: 05/12/2024] [Accepted: 05/24/2024] [Indexed: 06/13/2024]
Abstract
The glycomic analysis holds significant appeal due to the diverse roles that glycans and glycoconjugates play, acting as modulators and mediators in cellular interactions, cell/organism structure, drugs, energy sources, glyconanomaterials, and more. The glycomic analysis relies on liquid-phase separation technologies for molecular purification, separation, and identification. As a miniaturized form of liquid-phase separation technology, microscale separation technologies offer various advantages such as environmental friendliness, high resolution, sensitivity, fast speed, and integration capabilities. For glycan analysis, microscale separation technologies are continuously evolving to address the increasing challenges in their unique manners. This review discusses the fundamentals and applications of microscale separation technologies for glycomic analysis. It covers liquid-phase separation technologies operating at scales generally less than 100 µm, including capillary electrophoresis, nanoflow liquid chromatography, and microchip electrophoresis. We will provide a brief overview of glycomic analysis and describe new strategies in microscale separation and their applications in glycan analysis from 2014 to 2023.
Collapse
Affiliation(s)
- Chenchen Liu
- Department of Chemistry, Faculty of Science, Kyushu University, Fukuoka, Japan
| | - Koji Otsuka
- Department of Material Chemistry, Graduate School of Engineering, Kyoto University, Kyoto, Japan
- Research Administration Center, Osaka Metropolitan University, Osaka, Japan
| | - Takayuki Kawai
- Department of Chemistry, Faculty of Science, Kyushu University, Fukuoka, Japan
- RIKEN Center for Biosystems Dynamics Research, Osaka, Japan
| |
Collapse
|
3
|
Warren CG, Dasgupta PK. Liquid phase detection in the miniature scale. Microfluidic and capillary scale measurement and separation systems. A tutorial review. Anal Chim Acta 2024; 1305:342507. [PMID: 38677834 DOI: 10.1016/j.aca.2024.342507] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2024] [Revised: 03/18/2024] [Accepted: 03/19/2024] [Indexed: 04/29/2024]
Abstract
Microfluidic and capillary devices are increasingly being used in analytical applications while their overall size keeps decreasing. Detection sensitivity for these microdevices gains more importance as device sizes and consequently, sample volumes, decrease. This paper reviews optical, electrochemical, electrical, and mass spectrometric detection methods that are applicable to capillary scale and microfluidic devices, with brief introduction to the principles in each case. Much of this is considered in the context of separations. We do consider theoretical aspects of separations by open tubular liquid chromatography, arguably the most potentially fertile area of separations that has been left fallow largely because of lack of scale-appropriate detection methods. We also examine the theoretical basis of zone electrophoretic separations. Optical detection methods discussed include UV/Vis absorbance, fluorescence, chemiluminescence and refractometry. Amperometry is essentially the only electrochemical detection method used in microsystems. Suppressed conductance and especially contactless conductivity (admittance) detection are in wide use for the detection of ionic analytes. Microfluidic devices, integrated to various mass spectrometers, including ESI-MS, APCI-MS, and MALDI-MS are discussed. We consider the advantages and disadvantages of each detection method and compare the best reported limits of detection in as uniform a format as the available information allows. While this review pays more attention to recent developments, our primary focus has been on the novelty and ingenuity of the approach, regardless of when it was first proposed, as long as it can be potentially relevant to miniature platforms.
Collapse
Affiliation(s)
- Cable G Warren
- Department of Chemistry and Biochemistry, University of Texas at Arlington, Arlington, TX, 76019-0065, United States
| | - Purnendu K Dasgupta
- Department of Chemistry and Biochemistry, University of Texas at Arlington, Arlington, TX, 76019-0065, United States.
| |
Collapse
|
4
|
Haghighi F, Talebpour Z, Sanati-Nezhad A. Clogging sensitivity of flow distributors designed for radially elongated hexagonal pillar array columns: a computational modelling. Sci Rep 2021; 11:4927. [PMID: 33654139 PMCID: PMC7925673 DOI: 10.1038/s41598-021-84178-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2020] [Accepted: 01/20/2021] [Indexed: 11/18/2022] Open
Abstract
Flow distributor located at the beginning of the micromachined pillar array column (PAC) has significant roles in uniform distribution of flow through separation channels and thus separation efficiency. Chip manufacturing artifacts, contaminated solvents, and complex matrix of samples may contribute to clogging of the microfabricated channels, affect the distribution of the sample, and alter the performance of both natural and engineered systems. An even fluid distribution must be achieved cross-sectionally through careful design of flow distributors and minimizing the sensitivity to clogging in order to reach satisfactory separation efficiency. Given the difficulty to investigate experimentally a high number of clogging conditions and geometries, this work exploits a computational fluid dynamic model to investigate the effect of various design parameters on the performance of flow distributors in equally spreading the flow along the separation channels in the presence of different degrees of clogging. An array of radially elongated hexagonal pillars was selected for the separation channel (column). The design parameters include channel width, distributor width, aspect ratio of the pillars, and number of contact zone rows. The performance of known flow distributors, including bifurcating (BF), radially interconnected (RI), and recently introduced mixed-mode (MMI) in addition to two new distributors designed in this work (MMII and MMIII) were investigated in terms of mean elution time, volumetric variance, asymmetry factors, and pressure drop between the inlet and the monitor line for each design. The results show that except for pressure drop, the channel width and aspect ratio of the pillars has no significant influence on flow distribution pattern in non-clogged distributors. However, the behavior of flow distributors in response to clogging was found to be dependent on width of the channels. Also increasing the distributor width and number of contact zone rows after the first splitting stage showed no improvement in the ability to alleviate the clogging. MMI distributor with the channel width of 3 µm, aspect ratio of the pillars equal to 20, number of exits of 8, and number of contact zones of 3 exhibited the highest stability and minimum sensitivity to different degrees of clogging.
Collapse
Affiliation(s)
- Farideh Haghighi
- Department of Chemistry, Faculty of Physics and Chemistry, Alzahra University, Vanak, Tehran, Iran
- BioMEMS and Bioinspired Microfluidic Laboratory, Department of Mechanical and Manufacturing Engineering, Centre for Bioengineering Research and Education (CBRE), Biomedical Engineering Program, University of Calgary, Mechanical Engineering Building, MEB214, 2500 University Dr., N.W., Calgary, AB, T2N 1N4, Canada
| | - Zahra Talebpour
- Department of Chemistry, Faculty of Physics and Chemistry, Alzahra University, Vanak, Tehran, Iran.
| | - Amir Sanati-Nezhad
- BioMEMS and Bioinspired Microfluidic Laboratory, Department of Mechanical and Manufacturing Engineering, Centre for Bioengineering Research and Education (CBRE), Biomedical Engineering Program, University of Calgary, Mechanical Engineering Building, MEB214, 2500 University Dr., N.W., Calgary, AB, T2N 1N4, Canada.
| |
Collapse
|
5
|
Mielczarek P, Silberring J, Smoluch M. MINIATURIZATION IN MASS SPECTROMETRY. MASS SPECTROMETRY REVIEWS 2020; 39:453-470. [PMID: 31793697 DOI: 10.1002/mas.21614] [Citation(s) in RCA: 28] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/12/2019] [Accepted: 11/14/2019] [Indexed: 06/10/2023]
Abstract
Expectations for continuous miniaturization in mass spectrometry are not declining for years. Portable instruments are highly welcome by the industry, science, space agencies, forensic laboratories, and many other units. All are striving for the small, cheap, and as good as possible instruments. This review describes the recent developments of miniature mass spectrometers and also provides selected applications where these devices are used. Upcoming perspectives of further development are also discussed. @ 2019 John Wiley & Sons Ltd. Mass Spec Rev.
Collapse
Affiliation(s)
- Przemyslaw Mielczarek
- Department of Biochemistry and Neurobiology, Faculty of Materials Science and Ceramics, AGH University of Science and Technology, Mickiewicza 30, 30-059, Krakow, Poland
- Laboratory of Proteomics and Mass Spectrometry, Maj Institute of Pharmacology, Polish Academy of Sciences, Smetna 12, 31-343, Krakow, Poland
| | - Jerzy Silberring
- Department of Biochemistry and Neurobiology, Faculty of Materials Science and Ceramics, AGH University of Science and Technology, Mickiewicza 30, 30-059, Krakow, Poland
- Centre of Polymer and Carbon Materials, Polish Academy of Sciences, Curie-Sklodowskiej St. 34, 41-819, Zabrze, Poland
| | - Marek Smoluch
- Department of Biochemistry and Neurobiology, Faculty of Materials Science and Ceramics, AGH University of Science and Technology, Mickiewicza 30, 30-059, Krakow, Poland
| |
Collapse
|
6
|
Ahad H, Jin H, Liu Y, Wang J, Sun G, Liang X, Akber Aisa H. Chemical profiling of spermidines in goji berry by strong cation exchange solid-phase extraction (SCX-SPE) combined with ultrahigh-performance liquid chromatography-quadrupole time-of-flight mass spectrometry (UPLC-Q-TOF/MS/MS). J Chromatogr B Analyt Technol Biomed Life Sci 2020; 1137:121923. [DOI: 10.1016/j.jchromb.2019.121923] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2019] [Revised: 11/20/2019] [Accepted: 12/01/2019] [Indexed: 11/29/2022]
|
7
|
Martinez A, Knaub K, Monter M, Hekmat D, Weuster-Botz D. Improved packing of preparative biochromatography columns by mechanical vibration. Biotechnol Prog 2019; 36:e2950. [PMID: 31845490 DOI: 10.1002/btpr.2950] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2019] [Revised: 11/22/2019] [Accepted: 12/09/2019] [Indexed: 11/12/2022]
Abstract
The bioprocessing industry relies on packed-bed column chromatography as its primary separation process to attain the required high product purities and fulfill the strict requirements from regulatory bodies. Conventional column packing methods rely on flow packing and/or mechanical compression. In this work, the application of ultrasound and mechanical vibration during packing was studied with respect to packing density and homogeneity. We investigated two widely used biochromatography media, incompressible ceramic hydroxyapatite, and compressible polymethacrylate-based particles, packed in a laboratory-scale column with an inner diameter of 50 mm. It was shown that ultrasonic irradiation led to reduced particle segregation during sedimentation of a homogenized slurry of polymethacrylate particles. However, the application of ultrasound did not lead to an improved microstructure of already packed columns due to the low volumetric energy input (~152 W/L) caused by high acoustic reflection losses. In contrast, the application of pneumatic mechanical vibration led to considerable improvements. Flow-decoupled axial linear vibration was most suitable at a volumetric force output of ~1,190 N/L. In the case of the ceramic hydroxyapatite particles, a 13% further decrease of the packing height was achieved and the reduced height equivalent to a theoretical plate (rHETP) was decreased by 44%. For the polymethacrylate particles, a 18% further packing consolidation was achieved and the rHETP was reduced by 25%. Hence, it was shown that applying mechanical vibration resulted in more efficiently packed columns. The application of vibration furthermore is potentially suitable for in situ elimination of flow channels near the column wall.
Collapse
Affiliation(s)
- Andrés Martinez
- Technical University of Munich, Institute of Biochemical Engineering, Garching, Germany
| | - Konstantin Knaub
- Technical University of Munich, Institute of Biochemical Engineering, Garching, Germany
| | - Marc Monter
- Technical University of Munich, Institute of Biochemical Engineering, Garching, Germany
| | - Dariusch Hekmat
- Technical University of Munich, Institute of Biochemical Engineering, Garching, Germany
| | - Dirk Weuster-Botz
- Technical University of Munich, Institute of Biochemical Engineering, Garching, Germany
| |
Collapse
|
8
|
Salmean C, Dimartino S. 3D-Printed Stationary Phases with Ordered Morphology: State of the Art and Future Development in Liquid Chromatography. Chromatographia 2018. [DOI: 10.1007/s10337-018-3671-5] [Citation(s) in RCA: 40] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
9
|
Kecskemeti A, Gaspar A. Particle-based liquid chromatographic separations in microfluidic devices - A review. Anal Chim Acta 2018; 1021:1-19. [DOI: 10.1016/j.aca.2018.01.064] [Citation(s) in RCA: 46] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2017] [Revised: 01/18/2018] [Accepted: 01/21/2018] [Indexed: 01/06/2023]
|
10
|
Haghighi F, Talebpour Z, Nezhad AS. Towards fully integrated liquid chromatography on a chip: Evolution and evaluation. Trends Analyt Chem 2018. [DOI: 10.1016/j.trac.2018.05.002] [Citation(s) in RCA: 33] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
|
11
|
Lynch KB, Chen A, Liu S. Miniaturized high-performance liquid chromatography instrumentation. Talanta 2017; 177:94-103. [PMID: 29108588 DOI: 10.1016/j.talanta.2017.09.016] [Citation(s) in RCA: 49] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2017] [Revised: 09/04/2017] [Accepted: 09/06/2017] [Indexed: 12/26/2022]
Abstract
Miniaturized high performance liquid chromatography (HPLC) has attracted increasing attention for its potential in high-throughput analyses and point-of-care applications. In this review we highlight the recent advancements in HPLC system miniaturization. We focus on the major components that constitute these instruments along with their respective advantages and drawbacks as well as present a few representative miniaturized HPLC systems. We discuss briefly some of the applications and also anticipate the future development trends of these instrumental platforms.
Collapse
Affiliation(s)
- Kyle B Lynch
- Department of Chemistry and Biochemistry, University of Oklahoma, USA.
| | - Apeng Chen
- Department of Chemistry and Biochemistry, University of Oklahoma, USA
| | - Shaorong Liu
- Department of Chemistry and Biochemistry, University of Oklahoma, USA
| |
Collapse
|
12
|
Prototyping of thermoplastic microfluidic chips and their application in high-performance liquid chromatography separations of small molecules. J Chromatogr A 2017; 1523:224-233. [PMID: 28619590 DOI: 10.1016/j.chroma.2017.05.063] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2017] [Revised: 05/04/2017] [Accepted: 05/29/2017] [Indexed: 11/23/2022]
Abstract
The present paper discusses practical aspects of prototyping of microfluidic chips using cyclic olefin copolymer as substrate and the application in high-performance liquid chromatography. The developed chips feature a 60mm long straight separation channel with circular cross section (500μm i.d.) that was created using a micromilling robot. To irreversibly seal the top and bottom chip substrates, a solvent-vapor-assisted bonding approach was optimized, allowing to approximate the ideal circular channel geometry. Four different approaches to establish the micro-to-macro interface were pursued. The average burst pressure of the microfluidic chips in combination with an encasing holder was established at 38MPa and the maximum burst pressure was 47MPa, which is believed to be the highest ever report for these polymer-based microfluidic chips. Porous polymer monolithic frits were synthesized in-situ via UV-initiated polymerization and their locations were spatially controlled by the application of a photomask. Next, high-pressure slurry packing was performed to introduce 3μm silica reversed-phase particles as the stationary phase in the separation channel. Finally, the application of the chip technology is demonstrated for the separation of alkyl phenones in gradient mode yielding baseline peak widths of 6s by applying a steep gradient of 1.8min at a flow rate of 10μL/min.
Collapse
|
13
|
Reising AE, Godinho JM, Jorgenson JW, Tallarek U. Bed morphological features associated with an optimal slurry concentration for reproducible preparation of efficient capillary ultrahigh pressure liquid chromatography columns. J Chromatogr A 2017; 1504:71-82. [PMID: 28511930 DOI: 10.1016/j.chroma.2017.05.007] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2017] [Revised: 04/20/2017] [Accepted: 05/04/2017] [Indexed: 11/30/2022]
Abstract
Column wall effects and the formation of larger voids in the bed during column packing are factors limiting the achievement of highly efficient columns. Systematic variation of packing conditions, combined with three-dimensional bed reconstruction and detailed morphological analysis of column beds, provide valuable insights into the packing process. Here, we study a set of sixteen 75μm i.d. fused-silica capillary columns packed with 1.9μm, C18-modified, bridged-ethyl hybrid silica particles slurried in acetone to concentrations ranging from 5 to 200mg/mL. Bed reconstructions for three of these columns (representing low, optimal, and high slurry concentrations), based on confocal laser scanning microscopy, reveal morphological features associated with the implemented slurry concentration, that lead to differences in column efficiency. At a low slurry concentration, the bed microstructure includes systematic radial heterogeneities such as particle size-segregation and local deviations from bulk packing density near the wall. These effects are suppressed (or at least reduced) with higher slurry concentrations. Concomitantly, larger voids (relative to the mean particle diameter) begin to form in the packing and increase in size and number with the slurry concentration. The most efficient columns are packed at slurry concentrations that balance these counteracting effects. Videos are taken at low and high slurry concentration to elucidate the bed formation process. At low slurry concentrations, particles arrive and settle individually, allowing for rearrangements. At high slurry concentrations, they arrive and pack as large patches (reflecting particle aggregation in the slurry). These processes are discussed with respect to column packing, chromatographic performance, and bed microstructure to help reinforce general trends previously described. Conclusions based on this comprehensive analysis guide us towards further improvement of the packing process.
Collapse
Affiliation(s)
- Arved E Reising
- Department of Chemistry, Philipps-Universität Marburg, Hans-Meerwein-Strasse 4, 35032 Marburg, Germany
| | - Justin M Godinho
- Department of Chemistry, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599-3290, United States
| | - James W Jorgenson
- Department of Chemistry, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599-3290, United States.
| | - Ulrich Tallarek
- Department of Chemistry, Philipps-Universität Marburg, Hans-Meerwein-Strasse 4, 35032 Marburg, Germany.
| |
Collapse
|
14
|
Godinho JM, Reising AE, Tallarek U, Jorgenson JW. Implementation of high slurry concentration and sonication to pack high-efficiency, meter-long capillary ultrahigh pressure liquid chromatography columns. J Chromatogr A 2016; 1462:165-9. [PMID: 27499108 DOI: 10.1016/j.chroma.2016.08.002] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2016] [Revised: 07/28/2016] [Accepted: 08/01/2016] [Indexed: 11/20/2022]
Abstract
Slurry packing capillary columns for ultrahigh pressure liquid chromatography is complicated by many interdependent experimental variables. Previous results have suggested that combination of high slurry concentration and sonication during packing would create homogeneous bed microstructures and yield highly efficient capillary columns. Herein, the effect of sonication while packing very high slurry concentrations is presented. A series of six, 1m×75μm internal diameter columns were packed with 200mg/mL slurries of 2.02μm bridged-ethyl hybrid silica particles. Three of the columns underwent sonication during packing and yielded highly efficient separations with reduced plate heights as low as 1.05.
Collapse
Affiliation(s)
- Justin M Godinho
- Department of Chemistry, The University of North Carolina at Chapel Hill, Chapel Hill, NC, 27599-3290, United States
| | - Arved E Reising
- Department of Chemistry, Philipps-Universität, Marburg, Hans-Meerwein-Strasse 4, 35032 Marburg, Germany
| | - Ulrich Tallarek
- Department of Chemistry, Philipps-Universität, Marburg, Hans-Meerwein-Strasse 4, 35032 Marburg, Germany.
| | - James W Jorgenson
- Department of Chemistry, The University of North Carolina at Chapel Hill, Chapel Hill, NC, 27599-3290, United States.
| |
Collapse
|
15
|
Reising AE, Godinho JM, Hormann K, Jorgenson JW, Tallarek U. Larger voids in mechanically stable, loose packings of 1.3μm frictional, cohesive particles: Their reconstruction, statistical analysis, and impact on separation efficiency. J Chromatogr A 2016; 1436:118-32. [PMID: 26858113 DOI: 10.1016/j.chroma.2016.01.068] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2015] [Revised: 01/21/2016] [Accepted: 01/24/2016] [Indexed: 12/23/2022]
Abstract
Lateral transcolumn heterogeneities and the presence of larger voids in a packing (comparable to the particle size) can limit the preparation of efficient chromatographic columns. Optimizing and understanding the packing process provides keys to better packing structures and column performance. Here, we investigate the slurry-packing process for a set of capillary columns packed with C18-modified, 1.3μm bridged-ethyl hybrid porous silica particles. The slurry concentration used for packing 75μm i.d. fused-silica capillaries was increased gradually from 5 to 50mg/mL. An intermediate concentration (20mg/mL) resulted in the best separation efficiency. Three capillaries from the set representing low, intermediate, and high slurry concentrations were further used for three-dimensional bed reconstruction by confocal laser scanning microscopy and morphological analysis of the bed structure. Previous studies suggest increased slurry concentrations will result in higher column efficiency due to the suppression of transcolumn bed heterogeneities, but only up to a critical concentration. Too concentrated slurries favour the formation of larger packing voids (reaching the size of the average particle diameter). Especially large voids, which can accommodate particles from>90% of the particle size distribution, are responsible for a decrease in column efficiency at high slurry concentrations. Our work illuminates the increasing difficulty of achieving high bed densities with small, frictional, cohesive particles. As particle size decreases interparticle forces become increasingly important and hinder the ease of particle sliding during column packing. While an optimal slurry concentration is identified with respect to bed morphology and separation efficiency under conditions in this work, our results suggest adjustments of this concentration are required with regard to particle size, surface roughness, column dimensions, slurry liquid, and external effects utilized during the packing process (pressure protocol, ultrasound, electric fields).
Collapse
Affiliation(s)
- Arved E Reising
- Department of Chemistry, Philipps-Universität Marburg, Hans-Meerwein-Strasse 4, 35032 Marburg, Germany
| | - Justin M Godinho
- Department of Chemistry, The University of North Carolina at Chapel Hill, Chapel Hill, NC 27599-3290, United States
| | - Kristof Hormann
- Department of Chemistry, Philipps-Universität Marburg, Hans-Meerwein-Strasse 4, 35032 Marburg, Germany
| | - James W Jorgenson
- Department of Chemistry, The University of North Carolina at Chapel Hill, Chapel Hill, NC 27599-3290, United States.
| | - Ulrich Tallarek
- Department of Chemistry, Philipps-Universität Marburg, Hans-Meerwein-Strasse 4, 35032 Marburg, Germany.
| |
Collapse
|
16
|
Thurmann S, Dittmar A, Belder D. A low pressure on-chip injection strategy for high-performance chip-based chromatography. J Chromatogr A 2014; 1340:59-67. [DOI: 10.1016/j.chroma.2014.03.009] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2013] [Revised: 02/21/2014] [Accepted: 03/04/2014] [Indexed: 12/11/2022]
|
17
|
Bruns S, Franklin EG, Grinias JP, Godinho JM, Jorgenson JW, Tallarek U. Slurry concentration effects on the bed morphology and separation efficiency of capillaries packed with sub-2μm particles. J Chromatogr A 2013; 1318:189-97. [DOI: 10.1016/j.chroma.2013.10.017] [Citation(s) in RCA: 48] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
18
|
Affiliation(s)
- Gert Desmet
- Department of Chemical Engineering, Vrije Universiteit Brussel, Pleinlaan 2, B-1050 Brussels,
Belgium
| | - Sebastiaan Eeltink
- Department of Chemical Engineering, Vrije Universiteit Brussel, Pleinlaan 2, B-1050 Brussels,
Belgium
| |
Collapse
|
19
|
|
20
|
Daneyko A, Hlushkou D, Khirevich S, Tallarek U. From random sphere packings to regular pillar arrays: Analysis of transverse dispersion. J Chromatogr A 2012; 1257:98-115. [DOI: 10.1016/j.chroma.2012.08.024] [Citation(s) in RCA: 77] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2012] [Revised: 08/02/2012] [Accepted: 08/05/2012] [Indexed: 11/26/2022]
|
21
|
Lin SL, Bai HY, Lin TY, Fuh MR. Microfluidic chip-based liquid chromatography coupled to mass spectrometry for determination of small molecules in bioanalytical applications. Electrophoresis 2012; 33:635-43. [PMID: 22451056 DOI: 10.1002/elps.201100380] [Citation(s) in RCA: 41] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
The development and integration of microfabricated liquid chromatography (LC) microchips have increased dramatically in the last decade due to the needs of enhanced sensitivity and rapid analysis as well as the rising concern on reducing environmental impacts of chemicals used in various types of chemical and biochemical analyses. Recent development of microfluidic chip-based LC mass spectrometry (chip-based LC-MS) has played an important role in proteomic research for high throughput analysis. To date, the use of chip-based LC-MS for determination of small molecules, such as biomarkers, active pharmaceutical ingredients (APIs), and drugs of abuse and their metabolites, in clinical and pharmaceutical applications has not been thoroughly investigated. This mini-review summarizes the utilization of commercial chip-based LC-MS systems for determination of small molecules in bioanalytical applications, including drug metabolites and disease/tumor-associated biomarkers in clinical samples as well as adsorption, distribution, metabolism, and excretion studies of APIs in drug discovery and development. The different types of commercial chip-based interfaces for LC-MS analysis are discussed first and followed by applications of chip-based LC-MS on biological samples as well as the comparison with other LC-MS techniques.
Collapse
Affiliation(s)
- Shu-Ling Lin
- Department of Chemistry, Soochow University, Taipei, Taiwan
| | | | | | | |
Collapse
|
22
|
Mogensen KB, Kutter JP. Carbon nanotube based stationary phases for microchip chromatography. LAB ON A CHIP 2012; 12:1951-1958. [PMID: 22566131 DOI: 10.1039/c2lc40102a] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
The objective of this article is to provide an overview and critical evaluation of the use of carbon nanotubes and related carbon-based nanomaterials for microchip chromatography. The unique properties of carbon nanotubes, such as a very high surface area and intriguing adsorptive behaviour, have already been demonstrated in more classical formats, for improved separation performance in gas and liquid chromatography, and for unique applications in solid phase extraction. Carbon nanotubes are now also entering the field of microfluidics, where there is a large potential to be able to provide integrated, tailor-made nanotube columns by means of catalytic growth of the nanotubes inside the fluidic channels. An evaluation of the different implementations of carbon nanotubes and related carbon-based nanomaterials for microfluidic chromatography devices is given in terms of separation performance and ease of fabrication.
Collapse
Affiliation(s)
- Klaus B Mogensen
- Department of Micro- and Nanotechnology, Technical University of Denmark, DK-2800 Kgs. Lyngby, Denmark.
| | | |
Collapse
|
23
|
Zhu KY, Leung KW, Ting AKL, Wong ZCF, Ng WYY, Choi RCY, Dong TTX, Wang T, Lau DTW, Tsim KWK. Microfluidic chip based nano liquid chromatography coupled to tandem mass spectrometry for the determination of abused drugs and metabolites in human hair. Anal Bioanal Chem 2012; 402:2805-15. [PMID: 22281681 DOI: 10.1007/s00216-012-5711-6] [Citation(s) in RCA: 42] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2011] [Revised: 12/15/2011] [Accepted: 01/04/2012] [Indexed: 12/31/2022]
Abstract
A microfluidic chip based nano-HPLC coupled to tandem mass spectrometry (nano-HPLC-Chip-MS/MS) has been developed for simultaneous measurement of abused drugs and metabolites: cocaine, benzoylecgonine, cocaethylene, norcocaine, morphine, codeine, 6-acetylmorphine, phencyclidine, amphetamine, methamphetamine, MDMA, MDA, MDEA, and methadone in the hair of drug abusers. The microfluidic chip was fabricated by laminating polyimide films and it integrated an enrichment column, an analytical column and a nanospray tip. Drugs were extracted from hairs by sonication, and the chromatographic separation was achieved in 15 min. The drug identification and quantification criteria were fulfilled by the triple quardropule tandem mass spectrometry. The linear regression analysis was calibrated by deuterated internal standards with all of the R(2) at least over 0.993. The limit of detection (LOD) and the limit of quantification (LOQ) were from 0.1 to 0.75 and 0.2 to 1.25 pg/mg, respectively. The validation parameters including selectivity, accuracy, precision, stability, and matrix effect were also evaluated here. In conclusion, the developed sample preparation method coupled with the nano-HPLC-Chip-MS/MS method was able to reveal the presence of drugs in hairs from the drug abusers, with the enhanced sensitivity, compared with the conventional HPLC-MS/MS.
Collapse
Affiliation(s)
- Kevin Y Zhu
- Division of Life Science, The Hong Kong University of Science and Technology, Hong Kong
| | | | | | | | | | | | | | | | | | | |
Collapse
|
24
|
Kutter JP. Liquid phase chromatography on microchips. J Chromatogr A 2012; 1221:72-82. [DOI: 10.1016/j.chroma.2011.10.044] [Citation(s) in RCA: 81] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2011] [Revised: 10/12/2011] [Accepted: 10/17/2011] [Indexed: 01/12/2023]
|
25
|
Daneyko A, Khirevich S, Höltzel A, Seidel-Morgenstern A, Tallarek U. From random sphere packings to regular pillar arrays: Effect of the macroscopic confinement on hydrodynamic dispersion. J Chromatogr A 2011; 1218:8231-48. [DOI: 10.1016/j.chroma.2011.09.039] [Citation(s) in RCA: 62] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2011] [Revised: 09/06/2011] [Accepted: 09/13/2011] [Indexed: 11/16/2022]
|
26
|
GUAN Y, WU D, DUAN C. Advances in miniaturization of chromatograph and detectors. Se Pu 2011; 29:193-8. [DOI: 10.3724/sp.j.1123.2011.00193] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
|
27
|
Lavrik N, Taylor L, Sepaniak M. Nanotechnology and chip level systems for pressure driven liquid chromatography and emerging analytical separation techniques: A review. Anal Chim Acta 2011; 694:6-20. [DOI: 10.1016/j.aca.2011.03.059] [Citation(s) in RCA: 53] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2011] [Revised: 03/25/2011] [Accepted: 03/29/2011] [Indexed: 01/13/2023]
|
28
|
Integration of ground aerogel particles as chromatographic stationary phase into microchip. J Chromatogr A 2011; 1218:1011-5. [DOI: 10.1016/j.chroma.2010.12.091] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2010] [Revised: 12/18/2010] [Accepted: 12/20/2010] [Indexed: 11/18/2022]
|
29
|
Abstract
LC is one of the most powerful separation techniques as illustrated by its leading role in analytical sciences through both academic and industrial communities. Its implementation in microsystems appears to be crucial in the development of mu-Total Analysis System. If electrophoretic techniques have been widely used in miniaturized devices, LC has faced multiple challenges in the downsizing process. During the past 5 years, significant breakthroughs have been achieved in this research area, in both conception and use of LC on chip. This review emphasizes the development of novel stationary phases and their implementation in microchannels. Recent instrumental advances are also presented, highlighting the various driving forces (pressure, electrical field) that have been selected and their respective ranges of applications.
Collapse
Affiliation(s)
- Karine Faure
- Laboratoire des Sciences Analytiques, Université de Lyon, Villeurbanne, France.
| |
Collapse
|
30
|
Trusch M, Ehlert S, Bertsch A, Kohlbacher O, Hildebrand D, Schlüter H, Tallarek U. Improved particle-packed HPLC/MS microchips for proteomic analysis. J Sep Sci 2010; 33:3283-91. [DOI: 10.1002/jssc.201000474] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
|
31
|
Tao D, Zhang L, Shan Y, Liang Z, Zhang Y. Recent advances in micro-scale and nano-scale high-performance liquid-phase chromatography for proteome research. Anal Bioanal Chem 2010; 399:229-41. [PMID: 20683586 DOI: 10.1007/s00216-010-3946-7] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2010] [Revised: 06/18/2010] [Accepted: 06/20/2010] [Indexed: 10/25/2022]
Abstract
High-performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI-MS-MS) is regarded as one of the most powerful techniques for separation and identification of proteins. Recently, much effort has been made to improve the separation capacity, detection sensitivity, and analysis throughput of micro- and nano-HPLC, by increasing column length, reducing column internal diameter, and using integrated techniques. Development of HPLC columns has also been rapid, as a result of the use of submicrometer packing materials and monolithic columns. All these innovations result in clearly improved performance of micro- and nano-HPLC for proteome research.
Collapse
Affiliation(s)
- Dingyin Tao
- Key Laboratory of Separation Science for Analytical Chemistry, National Chromatographic R. & A. Center, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023, China
| | | | | | | | | |
Collapse
|
32
|
Flüssigkeitschromatographie - ihre Entwicklung und Bedeutung für die Lebenswissenschaften. Angew Chem Int Ed Engl 2010. [DOI: 10.1002/ange.200906976] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
33
|
Unger K, Ditz R, Machtejevas E, Skudas R. Liquid Chromatography-Its Development and Key Role in Life Science Applications. Angew Chem Int Ed Engl 2010; 49:2300-12. [DOI: 10.1002/anie.200906976] [Citation(s) in RCA: 56] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
34
|
Advances in the preparation of porous polymer monoliths in capillaries and microfluidic chips with focus on morphological aspects. Anal Bioanal Chem 2010; 397:953-60. [PMID: 20213170 DOI: 10.1007/s00216-010-3550-x] [Citation(s) in RCA: 64] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/24/2009] [Revised: 02/04/2010] [Accepted: 02/05/2010] [Indexed: 10/19/2022]
Abstract
Porous polymer monoliths have emerged as unique materials for many applications, including liquid-chromatographic analyses at an unrivaled speed, solid-phase extraction, and enzyme immobilization in capillary and microfluidic chip format. This article reviews the state of the art in the preparation of monoliths in narrow-bore capillaries and microfluidic chips and their miniaturization under conditions of spatial confinement. New developments in their preparation mainly using free radical polymerization techniques with a focus on morphological aspects in view of homogeneous porous materials are described. The suitability of monoliths for analysis of both large and small molecules is also discussed.
Collapse
|
35
|
Ehlert S, Trojer L, Vollmer M, van de Goor T, Tallarek U. Performance of HPLC/MS microchips in isocratic and gradient elution modes. JOURNAL OF MASS SPECTROMETRY : JMS 2010; 45:313-320. [PMID: 20209581 DOI: 10.1002/jms.1719] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
We analyzed the chromatographic performance of particle-packed, all-polyimide high-performance liquid chromatography/mass spectrometry (HPLC/MS) microchips in terms of their hydraulic permeabilities and separation efficiency under isocratic and gradient elution conditions. The separation channels of the chips (with ca 50 microm x 75 microm trapezoidal cross-section and a length of 43 mm) were slurry packed with either 3.5 or 5 microm spherical porous C18-silica particles. A custom-built holder enveloped the chip during packing to prevent channel deformation and delamination from high pressures. It is shown that the packing conditions significantly impact the packing density of the HPLC/MS chips, which determines their performance in both, isocratic and gradient elution modes. Even with steep solvent gradients, peak shape and chromatographic resolution for the densely packed HPLC/MS chips are much improved. Our data show that the analytical power of the HPLC/MS chip is limited by the quality of the chromatographic separation.
Collapse
Affiliation(s)
- Steffen Ehlert
- Department of Chemistry, Philipps-Universität Marburg, Hans-Meerwein-Strasse, 35032 Marburg, Germany
| | | | | | | | | |
Collapse
|
36
|
Bai HY, Lin SL, Chan SA, Fuh MR. Characterization and evaluation of two-dimensional microfluidic chip-HPLC coupled to tandem mass spectrometry for quantitative analysis of 7-aminoflunitrazepam in human urine. Analyst 2010; 135:2737-42. [DOI: 10.1039/c0an00355g] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
|
37
|
Jung S, Ehlert S, Pattky M, Tallarek U. Determination of the interparticle void volume in packed beds via intraparticle Donnan exclusion. J Chromatogr A 2010; 1217:696-704. [DOI: 10.1016/j.chroma.2009.12.010] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2009] [Revised: 11/26/2009] [Accepted: 12/02/2009] [Indexed: 11/17/2022]
|
38
|
Jung S, Höltzel A, Ehlert S, Mora JA, Kraiczek K, Dittmann M, Rozing GP, Tallarek U. Impact of Conduit Geometry on the Performance of Typical Particulate Microchip Packings. Anal Chem 2009; 81:10193-200. [DOI: 10.1021/ac902069x] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
- Stephanie Jung
- Department of Chemistry, Philipps-Universität Marburg, Hans-Meerwein-Strasse, 35032 Marburg, Germany, and Agilent Technologies, Hewlett-Packard-Strasse 8, 76337 Waldbronn, Germany
| | - Alexandra Höltzel
- Department of Chemistry, Philipps-Universität Marburg, Hans-Meerwein-Strasse, 35032 Marburg, Germany, and Agilent Technologies, Hewlett-Packard-Strasse 8, 76337 Waldbronn, Germany
| | - Steffen Ehlert
- Department of Chemistry, Philipps-Universität Marburg, Hans-Meerwein-Strasse, 35032 Marburg, Germany, and Agilent Technologies, Hewlett-Packard-Strasse 8, 76337 Waldbronn, Germany
| | - Jose-Angel Mora
- Department of Chemistry, Philipps-Universität Marburg, Hans-Meerwein-Strasse, 35032 Marburg, Germany, and Agilent Technologies, Hewlett-Packard-Strasse 8, 76337 Waldbronn, Germany
| | - Karsten Kraiczek
- Department of Chemistry, Philipps-Universität Marburg, Hans-Meerwein-Strasse, 35032 Marburg, Germany, and Agilent Technologies, Hewlett-Packard-Strasse 8, 76337 Waldbronn, Germany
| | - Monika Dittmann
- Department of Chemistry, Philipps-Universität Marburg, Hans-Meerwein-Strasse, 35032 Marburg, Germany, and Agilent Technologies, Hewlett-Packard-Strasse 8, 76337 Waldbronn, Germany
| | - Gerard P. Rozing
- Department of Chemistry, Philipps-Universität Marburg, Hans-Meerwein-Strasse, 35032 Marburg, Germany, and Agilent Technologies, Hewlett-Packard-Strasse 8, 76337 Waldbronn, Germany
| | - Ulrich Tallarek
- Department of Chemistry, Philipps-Universität Marburg, Hans-Meerwein-Strasse, 35032 Marburg, Germany, and Agilent Technologies, Hewlett-Packard-Strasse 8, 76337 Waldbronn, Germany
| |
Collapse
|
39
|
Reinsberg KG, Effelsberg U, Tallarek U. Microchip electrospray performance during gradient elution with bulk conductivity changes. LAB ON A CHIP 2009; 9:2914-2923. [PMID: 19789744 DOI: 10.1039/b905052c] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
This work identifies dynamic changes in bulk conductivity during reversed-phase HPLC gradient elution as a major source for spray mode changes and instabilities observed in ESI-MS. A commercial microchip-HPLC/ESI-MS configuration was modified to enable electrospray diagnostics based on frequency analysis of the microchip emitter current combined with spray imaging. This approach facilitated detection of different spray modes together with their onset potentials. Water/acetonitrile mixtures containing formic acid were selected as the electrosprayed solutions to represent typical conditions in reversed-phase HPLC. Experimental data are complemented by computational fluid dynamics simulations, treating the electrosprayed solution as leaky dielectric fluid, to address the influence of bulk conductivity and applied potential difference on the developing cone-jet morphology and stability.
Collapse
Affiliation(s)
- Klaus-Georg Reinsberg
- Department of Chemistry, Philipps-Universität Marburg, Hans-Meerwein-Strasse, 35032 Marburg, Germany
| | | | | |
Collapse
|
40
|
Robotti KM, Yin H, Brennen R, Trojer L, Killeen K. Microfluidic HPLC-Chip devices with integral channels containing methylstyrenic-based monolithic media. J Sep Sci 2009; 32:3379-87. [DOI: 10.1002/jssc.200900379] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
41
|
Khirevich S, Höltzel A, Ehlert S, Seidel-Morgenstern A, Tallarek U. Large-Scale Simulation von Fluss und Transport in rekonstruierten Festbetten. CHEM-ING-TECH 2009. [DOI: 10.1002/cite.200950055] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
42
|
Khirevich S, Höltzel A, Ehlert S, Seidel-Morgenstern A, Tallarek U. Large-Scale Simulation of Flow and Transport in Reconstructed HPLC-Microchip Packings. Anal Chem 2009; 81:4937-45. [DOI: 10.1021/ac900631d] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
- Siarhei Khirevich
- Department of Chemistry, Philipps-Universität Marburg, Hans-Meerwein-Strasse, 35032 Marburg, Germany, and Max-Planck-Institut für Dynamik komplexer technischer Systeme, Sandtorstrasse 1, 39106 Magdeburg, Germany
| | - Alexandra Höltzel
- Department of Chemistry, Philipps-Universität Marburg, Hans-Meerwein-Strasse, 35032 Marburg, Germany, and Max-Planck-Institut für Dynamik komplexer technischer Systeme, Sandtorstrasse 1, 39106 Magdeburg, Germany
| | - Steffen Ehlert
- Department of Chemistry, Philipps-Universität Marburg, Hans-Meerwein-Strasse, 35032 Marburg, Germany, and Max-Planck-Institut für Dynamik komplexer technischer Systeme, Sandtorstrasse 1, 39106 Magdeburg, Germany
| | - Andreas Seidel-Morgenstern
- Department of Chemistry, Philipps-Universität Marburg, Hans-Meerwein-Strasse, 35032 Marburg, Germany, and Max-Planck-Institut für Dynamik komplexer technischer Systeme, Sandtorstrasse 1, 39106 Magdeburg, Germany
| | - Ulrich Tallarek
- Department of Chemistry, Philipps-Universität Marburg, Hans-Meerwein-Strasse, 35032 Marburg, Germany, and Max-Planck-Institut für Dynamik komplexer technischer Systeme, Sandtorstrasse 1, 39106 Magdeburg, Germany
| |
Collapse
|
43
|
Lee J, Soper SA, Murray KK. Microfluidic chips for mass spectrometry-based proteomics. JOURNAL OF MASS SPECTROMETRY : JMS 2009; 44:579-93. [PMID: 19373851 DOI: 10.1002/jms.1585] [Citation(s) in RCA: 77] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
Microfluidic devices coupled to mass spectrometers have emerged as excellent tools for solving the complex analytical challenges associated with the field of proteomics. Current proteome identification procedures are accomplished through a series of steps that require many hours of labor-intensive work. Microfluidics can play an important role in proteomic sample preparation steps prior to mass spectral identification such as sample cleanup, digestion, and separations due to its ability to handle small sample quantities with the potential for high-throughput parallel analysis. To utilize microfluidic devices for proteomic analysis, an efficient interface between the microchip and the mass spectrometer is required. This tutorial provides an overview of the technologies and applications of microfluidic chips coupled to mass spectrometry for proteome analysis. Various approaches for combining microfluidic devices with electrospray ionization (ESI) and matrix-assisted laser desorption/ionization (MALDI) are summarized and applications of chip-based separations and digestion technologies to proteomic analysis are presented.
Collapse
Affiliation(s)
- Jeonghoon Lee
- Department of Chemistry, Louisiana State University, Baton Rouge, Louisiana 70803, USA
| | | | | |
Collapse
|
44
|
Jung S, Ehlert S, Mora JA, Kraiczek K, Dittmann M, Rozing GP, Tallarek U. Packing density, permeability, and separation efficiency of packed microchips at different particle-aspect ratios. J Chromatogr A 2009; 1216:264-73. [DOI: 10.1016/j.chroma.2008.11.073] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2008] [Revised: 11/21/2008] [Accepted: 11/26/2008] [Indexed: 10/21/2022]
|
45
|
Khirevich S, Höltzel A, Hlushkou D, Seidel-Morgenstern A, Tallarek U. Structure-transport analysis for particulate packings in trapezoidal microchip separation channels. LAB ON A CHIP 2008; 8:1801-1808. [PMID: 18941678 DOI: 10.1039/b810688f] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
This article investigates the efficiency of particulate beds confined in quadrilateral microchannels by analyzing the three-dimensional fluid flow velocity field and accompanying hydrodynamic dispersion with quantitative numerical simulation methods. Random-close packings of uniform, solid (impermeable), spherical particles of diameter d(p) were generated by a modified Jodrey-Tory algorithm in eighteen different conduits with quadratic, rectangular, or trapezoidal cross-section at an average bed porosity (interparticle void fraction) of epsilon = 0.48. Velocity fields were calculated by the lattice Boltzmann method, and axial hydrodynamic dispersion of an inert tracer was simulated at Péclet numbers Pe = u(av)d(p)/D(m) (where u(av) is the average fluid flow velocity through a packing and D(m) the bulk molecular diffusion coefficient) from Pe = 5 to Pe = 30 by a Lagrangian particle-tracking method. All conduits had a cross-sectional area of 100d(p)(2) and a length of 1200d(p), translating to around 10(5) particles per packing. We present lateral porosity distribution functions and analyze fluid flow profiles and velocity distribution functions with respect to the base angle and the aspect ratio of the lateral dimensions of the different conduits. We demonstrate significant differences between the top and bottom parts of trapezoidal packings in their lateral porosity and velocity distribution functions, and show that these differences increase with decreasing base angle and increasing base-aspect ratio of a trapezoidal conduit, i.e., with increasing deviation from regular rectangular geometry. Efficiencies are investigated in terms of the axial hydrodynamic dispersion coefficients as a function of the base angle and base-aspect ratio of the conduits. The presented data support the conclusion that the efficiency of particulate beds in trapezoidal microchannels strongly depends on the lateral dimensions of the conduit and that cross-sectional designs based on large side-aspect-ratio rectangles with limited deviations from orthogonality are favorable.
Collapse
Affiliation(s)
- Siarhei Khirevich
- Department of Chemistry, Philipps-Universität Marburg, Hans-Meerwein-Strasse, 35032, Marburg, Germany
| | | | | | | | | |
Collapse
|