1
|
Wang Q, Yang C, Chen S, Li J. Miniaturized Electrochemical Sensing Platforms for Quantitative Monitoring of Glutamate Dynamics in the Central Nervous System. Angew Chem Int Ed Engl 2024; 63:e202406867. [PMID: 38829963 DOI: 10.1002/anie.202406867] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2024] [Revised: 05/30/2024] [Accepted: 06/03/2024] [Indexed: 06/05/2024]
Abstract
Glutamate is one of the most important excitatory neurotransmitters within the mammalian central nervous system. The role of glutamate in regulating neural network signaling transmission through both synaptic and extra-synaptic paths highlights the importance of the real-time and continuous monitoring of its concentration and dynamics in living organisms. Progresses in multidisciplinary research have promoted the development of electrochemical glutamate sensors through the co-design of materials, interfaces, electronic devices, and integrated systems. This review summarizes recent works reporting various electrochemical sensor designs and their applicability as miniaturized neural probes to in vivo sensing within biological environments. We start with an overview of the role and physiological significance of glutamate, the metabolic routes, and its presence in various bodily fluids. Next, we discuss the design principles, commonly employed validation models/protocols, and successful demonstrations of multifunctional, compact, and bio-integrated devices in animal models. The final section provides an outlook on the development of the next generation glutamate sensors for neuroscience and neuroengineering, with the aim of offering practical guidance for future research.
Collapse
Affiliation(s)
- Qi Wang
- Department of Materials Science and Engineering, The Ohio State University, Columbus, OH 43210, USA
| | - Chunyu Yang
- Department of Materials Science and Engineering, The Ohio State University, Columbus, OH 43210, USA
| | - Shulin Chen
- Department of Materials Science and Engineering, The Ohio State University, Columbus, OH 43210, USA
| | - Jinghua Li
- Department of Materials Science and Engineering, The Ohio State University, Columbus, OH 43210, USA
- Chronic Brain Injury Program, The Ohio State University, Columbus, OH 43210, USA
| |
Collapse
|
2
|
Liu X, Yin B, Yang C, Wu S. Passivation strategies for enhancing sensitivity and repeatability of microelectrode electrochemical sensors. Talanta 2024; 273:125946. [PMID: 38508127 DOI: 10.1016/j.talanta.2024.125946] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2024] [Revised: 03/05/2024] [Accepted: 03/16/2024] [Indexed: 03/22/2024]
Abstract
The sensitivity and repeatability are crucial for the practical application of electrochemical sensors. Many studies have focused on sensing materials and electrode structure to enhance sensitivity and repeatability rather than insulating layers. In this paper, polyaniline (PANI) microelectrode arrays were prepared to explore the influence of the insulating layer on sensitivity and repeatability of electrochemical sensors. The effects of different types of insulating layers, the sizes of the electrodes, and the thicknesses of the insulating layers were studied by experiment and simulation. The research findings indicated that the kind of organic insulating layers (Polyimide (PI) and SU-8) did not have a significant effect on the performance of the sensors. However, as the electrode area increased, the PANI film deposited on the electrode exhibited improved uniformity and density, leading to significant improvements in sensitivity and repeatability of the sensors. Additionally, the thickness of the insulating layer also had a significant impact on the performance of the device. The microelectrode with thinner insulating layers exhibited improved performance in sensitivity, repeatability and signal-to-noise ratio. The research findings indicated that increasing the electrode size and reducing the thickness of the insulating layer led to a more uniform and dense PANI film, resulting in an array electrode that exhibits excellent performance and remarkable repeatability.
Collapse
Affiliation(s)
- Xiaobo Liu
- School of Chemistry, Dalian University of Technology, Dalian 116023, PR China
| | - Bing Yin
- School of Chemistry, Dalian University of Technology, Dalian 116023, PR China.
| | - Cheng Yang
- School of Chemistry, Dalian University of Technology, Dalian 116023, PR China
| | - Shuo Wu
- School of Chemistry, Dalian University of Technology, Dalian 116023, PR China.
| |
Collapse
|
3
|
Liu R, Zhang S, Zeng H, Gao N, Yin Y, Zhang M, Mao L. A Potentiometric Dual-Channel Microsensor Reveals that Fluctuation of H 2 S is Less pH-Dependent During Spreading Depolarization in the Rat Brain. Angew Chem Int Ed Engl 2024; 63:e202318973. [PMID: 38272831 DOI: 10.1002/anie.202318973] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2023] [Revised: 01/23/2024] [Accepted: 01/25/2024] [Indexed: 01/27/2024]
Abstract
Spreading depolarization (SD) is one of the most common neuropathologic phenomena in the nervous system, relating to numerous diseases. However, real-time monitoring the rapid chemical changes during SD to probe the molecular mechanism remains a great challenge. We develop a potentiometric dual-channel microsensor for simultaneous monitoring of H2 S and pH featuring excellent selectivity and spatiotemporal resolution. Using this microsensor we first observe real time changes of H2 S and pH in the rat brain induced by SD. This changes of H2 S are completely suppressed when the rat pre-treats with aminooxyacetic acid (AOAA), a blocker to inhibit the H2 S-producing enzyme, indicating H2 S fluctuation might be related to enzyme-dependent pathway during SD and less pH-dependent. This study provides a new perspective for studying the function of H2 S and the molecular basis of SD-associated diseases.
Collapse
Affiliation(s)
- Rantong Liu
- Key Laboratory of Advanced Light Conversion Materials and Biophotonics, Department of Chemistry, Renmin University of China, Beijing, 100872, China
- College of Petroleum and Environment Engineering, Yan'an University, Shaanxi Yan'an, 716000, China
| | - Shuai Zhang
- Key Laboratory of Advanced Light Conversion Materials and Biophotonics, Department of Chemistry, Renmin University of China, Beijing, 100872, China
| | - Hui Zeng
- Key Laboratory of Advanced Light Conversion Materials and Biophotonics, Department of Chemistry, Renmin University of China, Beijing, 100872, China
| | - Nan Gao
- Key Laboratory of Advanced Light Conversion Materials and Biophotonics, Department of Chemistry, Renmin University of China, Beijing, 100872, China
| | - Yongyue Yin
- Key Laboratory of Advanced Light Conversion Materials and Biophotonics, Department of Chemistry, Renmin University of China, Beijing, 100872, China
| | - Meining Zhang
- Key Laboratory of Advanced Light Conversion Materials and Biophotonics, Department of Chemistry, Renmin University of China, Beijing, 100872, China
| | - Lanqun Mao
- College of Chemistry, Beijing Normal University, Beijing, 100875, China
| |
Collapse
|
4
|
Hu C, Wang L, Liu S, Sheng X, Yin L. Recent Development of Implantable Chemical Sensors Utilizing Flexible and Biodegradable Materials for Biomedical Applications. ACS NANO 2024; 18:3969-3995. [PMID: 38271679 DOI: 10.1021/acsnano.3c11832] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/27/2024]
Abstract
Implantable chemical sensors built with flexible and biodegradable materials exhibit immense potential for seamless integration with biological systems by matching the mechanical properties of soft tissues and eliminating device retraction procedures. Compared with conventional hospital-based blood tests, implantable chemical sensors have the capability to achieve real-time monitoring with high accuracy of important biomarkers such as metabolites, neurotransmitters, and proteins, offering valuable insights for clinical applications. These innovative sensors could provide essential information for preventive diagnosis and effective intervention. To date, despite extensive research on flexible and bioresorbable materials for implantable electronics, the development of chemical sensors has faced several challenges related to materials and device design, resulting in only a limited number of successful accomplishments. This review highlights recent advancements in implantable chemical sensors based on flexible and biodegradable materials, encompassing their sensing strategies, materials strategies, and geometric configurations. The following discussions focus on demonstrated detection of various objects including ions, small molecules, and a few examples of macromolecules using flexible and/or bioresorbable implantable chemical sensors. Finally, we will present current challenges and explore potential future directions.
Collapse
Affiliation(s)
- Chen Hu
- School of Materials Science and Engineering, The Key Laboratory of Advanced Materials of Ministry of Education, State Key Laboratory of New Ceramics and Fine Processing, Laboratory of Flexible Electronics Technology, Tsinghua University, Beijing 100084, P. R. China
| | - Liu Wang
- Key Laboratory of Biomechanics and Mechanobiology of Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing 100083, P. R. China
| | - Shangbin Liu
- School of Materials Science and Engineering, The Key Laboratory of Advanced Materials of Ministry of Education, State Key Laboratory of New Ceramics and Fine Processing, Laboratory of Flexible Electronics Technology, Tsinghua University, Beijing 100084, P. R. China
| | - Xing Sheng
- Department of Electronic Engineering, Beijing National Research Center for Information Science and Technology, Institute for Precision Medicine, Laboratory of Flexible Electronics Technology, IDG/McGovern Institute for Brain Research, Tsinghua University, Beijing 100084, P. R. China
| | - Lan Yin
- School of Materials Science and Engineering, The Key Laboratory of Advanced Materials of Ministry of Education, State Key Laboratory of New Ceramics and Fine Processing, Laboratory of Flexible Electronics Technology, Tsinghua University, Beijing 100084, P. R. China
| |
Collapse
|
5
|
Chen J, Ding X, Zhang D. Challenges and strategies faced in the electrochemical biosensing analysis of neurochemicals in vivo: A review. Talanta 2024; 266:124933. [PMID: 37506520 DOI: 10.1016/j.talanta.2023.124933] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2023] [Revised: 07/07/2023] [Accepted: 07/10/2023] [Indexed: 07/30/2023]
Abstract
Our brain is an intricate neuromodulatory network, and various neurochemicals, including neurotransmitters, neuromodulators, gases, ions, and energy metabolites, play important roles in regulating normal brain function. Abnormal release or imbalance of these substances will lead to various diseases such as Parkinson's and Alzheimer's diseases, therefore, in situ and real-time analysis of neurochemical interactions in pathophysiological conditions is beneficial to facilitate our understanding of brain function. Implantable electrochemical biosensors are capable of monitoring neurochemical signals in real time in extracellular fluid of specific brain regions because they can provide excellent temporal and spatial resolution. However, in vivo electrochemical biosensing analysis mainly faces the following challenges: First, foreign body reactions induced by microelectrode implantation, non-specific adsorption of proteins and redox products, and aggregation of glial cells, which will cause irreversible degradation of performance such as stability and sensitivity of the microsensor and eventually lead to signal loss; Second, various neurochemicals coexist in the complex brain environment, and electroactive substances with similar formal potentials interfere with each other. Therefore, it is a great challenge to design recognition molecules and tailor functional surfaces to develop in vivo electrochemical biosensors with high selectivity. Here, we take the above challenges as a starting point and detail the basic design principles for improving in vivo stability, selectivity and sensitivity of microsensors through some specific functionalized surface strategies as case studies. At the same time, we summarize surface modification strategies for in vivo electrochemical biosensing analysis of some important neurochemicals for researchers' reference. In addition, we also focus on the electrochemical detection of low basal concentrations of neurochemicals in vivo via amperometric waveform techniques, as well as the stability and biocompatibility of reference electrodes during long-term sensing, and provide an outlook on the future direction of in vivo electrochemical neurosensing.
Collapse
Affiliation(s)
- Jiatao Chen
- School of Pharmacy, Health Science Center, Xi'an Jiaotong University, Xi'an, 710061, China
| | - Xiuting Ding
- School of Pharmacy, Health Science Center, Xi'an Jiaotong University, Xi'an, 710061, China
| | - Dongdong Zhang
- School of Pharmacy, Health Science Center, Xi'an Jiaotong University, Xi'an, 710061, China.
| |
Collapse
|
6
|
Zheng Z, Liu L, Ouyang S, Chen Y, Lin P, Chen H, You Y, Zhao P, Huang K, Tao J. In Situ Ratiometric Determination of Cerebral Ascorbic Acid after Ischemia Reperfusion. ACS Sens 2023; 8:4587-4596. [PMID: 38038440 DOI: 10.1021/acssensors.3c01515] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/02/2023]
Abstract
Ascorbic acid (AA) is significant in protecting the brain from further damage and maintaining brain homeostasis after ischemia stroke (IS); however, the dynamic change of cerebral AA content after different degrees of ischemic stroke is still unclear. Herein, carboxylated single-walled carbon nanotube (CNT-COOH)- and polyethylenedioxythiophene (PEDOT)-modified carbon fiber microelectrodes (CFEs) were proposed to detect in situ cerebral AA with sensitivity, selectivity, and stability. Under differential pulse voltammetry scanning, the CFE/CNT-COOH/PEDOT gave a ratiometric, electrochemically responsive signal. The internal standard peak at -310 mV was from the reversible peak of O2 reduction and the deprotonation and protonation of quinone groups, while AA was oxidized at -70 mV. In vivo experimental results indicated that the cerebral AA level gradually increased with the ischemic time increasing in different middle cerebral artery occlusion (MCAO) model mice. This work implies that the increasing cerebral AA level may be highly related to the glutamate excitotoxicity and ROS-led cell apoptosis and paves a new way for further understanding the release and metabolic mechanisms of AA during ischemia reperfusion and IS.
Collapse
Affiliation(s)
- Zhiyuan Zheng
- NMPA Key Laboratory for Research and Evaluation of Drug Metabolism, Guangdong Provincial Key Laboratory of Cardiac Function and Microcirculation, Guangdong Provincial Key Laboratory of New Drug Screening, School of Pharmaceutical Sciences, Southern Medical University, 510515 Guangzhou, China
| | - Lina Liu
- School of Chemistry and Chemical Engineering, South China University of Technology, 510640 Guangzhou, China
| | - Sixue Ouyang
- School of Chemistry and Chemical Engineering, South China University of Technology, 510640 Guangzhou, China
| | - Yuying Chen
- School of Chemistry and Chemical Engineering, South China University of Technology, 510640 Guangzhou, China
| | - Peiru Lin
- NMPA Key Laboratory for Research and Evaluation of Drug Metabolism, Guangdong Provincial Key Laboratory of Cardiac Function and Microcirculation, Guangdong Provincial Key Laboratory of New Drug Screening, School of Pharmaceutical Sciences, Southern Medical University, 510515 Guangzhou, China
| | - Huiting Chen
- School of Chemistry and Chemical Engineering, South China University of Technology, 510640 Guangzhou, China
| | - Yuanyuan You
- NMPA Key Laboratory for Research and Evaluation of Drug Metabolism, Guangdong Provincial Key Laboratory of Cardiac Function and Microcirculation, Guangdong Provincial Key Laboratory of New Drug Screening, School of Pharmaceutical Sciences, Southern Medical University, 510515 Guangzhou, China
| | - Peng Zhao
- NMPA Key Laboratory for Research and Evaluation of Drug Metabolism, Guangdong Provincial Key Laboratory of Cardiac Function and Microcirculation, Guangdong Provincial Key Laboratory of New Drug Screening, School of Pharmaceutical Sciences, Southern Medical University, 510515 Guangzhou, China
| | - Kaibin Huang
- Department of Neurology, Nanfang Hospital, Southern Medical University, 510515 Guangzhou, China
| | - Jia Tao
- School of Chemistry and Chemical Engineering, South China University of Technology, 510640 Guangzhou, China
| |
Collapse
|
7
|
Zhou L, Yang R, Li X, Dong N, Zhu B, Wang J, Lin X, Su B. COF-Coated Microelectrode for Space-Confined Electrochemical Sensing of Dopamine in Parkinson's Disease Model Mouse Brain. J Am Chem Soc 2023; 145:23727-23738. [PMID: 37859408 DOI: 10.1021/jacs.3c08256] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2023]
Abstract
Parkinson's disease (PD) is a progressive neurodegenerative disorder causing the loss of dopaminergic neurons in the substantia nigra and the drastic depletion of dopamine (DA) in the striatum; thus, DA can act as a marker for PD diagnosis and therapeutic evaluation. However, detecting DA in the brain is not easy because of its low concentration and difficulty in sampling. In this work, we report the fabrication of a covalent organic framework (COF)-modified carbon fiber microelectrode (cCFE) that enables the real-time detection of DA in the mouse brain thanks to the outstanding antibiofouling and antichemical fouling ability, excellent analytical selectivity, and sensitivity offered by the COF modification. In particular, the COF can inhibit the polymerization of DA on the electrode (namely, chemical fouling) by spatially confining the molecular conformation and electrochemical oxidation of DA. The cCFE can stably and continuously work in the mouse brain to detect DA and monitor the variation of its concentration. Furthermore, it was combined with levodopa administration to devise a closed-loop feedback mode for PD diagnosis and therapy, in which the cCFE real-time monitors the concentration of DA in the PD model mouse brain to instruct the dose and injection time of levodopa, allowing a customized medication to improve therapeutic efficacy and meanwhile avoid adverse side effects. This work demonstrates the fascinating properties of a COF in fabricating electrochemical sensors for in vivo bioanalysis. We believe that the COF with structural tunability and diversity will offer enormous promise for selective detection of neurotransmitters in the brain.
Collapse
Affiliation(s)
- Lin Zhou
- Institute of Analytical Chemistry, Department of Chemistry, Zhejiang University, Hangzhou 310058, China
- College of Biosystems Engineering and Food Science, State Key Laboratory of Fluid Power and Mechatronic Systems, Zhejiang University, Hangzhou 310058, China
| | - Rongjie Yang
- Institute of Analytical Chemistry, Department of Chemistry, Zhejiang University, Hangzhou 310058, China
| | - Xinru Li
- Institute of Analytical Chemistry, Department of Chemistry, Zhejiang University, Hangzhou 310058, China
| | - Nuo Dong
- Institute of Analytical Chemistry, Department of Chemistry, Zhejiang University, Hangzhou 310058, China
| | - Boyu Zhu
- Institute of Analytical Chemistry, Department of Chemistry, Zhejiang University, Hangzhou 310058, China
| | - Jingjing Wang
- College of Biosystems Engineering and Food Science, State Key Laboratory of Fluid Power and Mechatronic Systems, Zhejiang University, Hangzhou 310058, China
| | - Xingyu Lin
- College of Biosystems Engineering and Food Science, State Key Laboratory of Fluid Power and Mechatronic Systems, Zhejiang University, Hangzhou 310058, China
| | - Bin Su
- Institute of Analytical Chemistry, Department of Chemistry, Zhejiang University, Hangzhou 310058, China
| |
Collapse
|
8
|
Wu F, Yu P, Mao L. New Opportunities of Electrochemistry for Monitoring, Modulating, and Mimicking the Brain Signals. JACS AU 2023; 3:2062-2072. [PMID: 37654584 PMCID: PMC10466370 DOI: 10.1021/jacsau.3c00220] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/03/2023] [Revised: 07/14/2023] [Accepted: 07/28/2023] [Indexed: 09/02/2023]
Abstract
In vivo electrochemistry is a powerful key for unlocking the chemical consequences in neural networks of the brain. The past half-century has witnessed the technology revolutionization in this field along with innovations in electrochemical concepts, principles, methods, and devices. Present applications of electrochemical approaches have extended from measuring neurochemical concentrations to modulating and mimicking brain signals. In this Perspective, newly reported strategies for tackling long-standing challenges of in vivo electrochemical brain monitoring (i.e., basal level measurement, electroactivity dependence, in vivo stability, neuron compatibility, multiplexity, and implantable device fabrication) are highlighted. Moreover, recent progress on neuromodulation tools and neuromorphic devices in electrochemical frameworks is introduced. A glimpse of future opportunities for electrochemistry in brain research is offered at last.
Collapse
Affiliation(s)
- Fei Wu
- College
of Chemistry, Beijing Normal University, Beijing 100875, China
| | - Ping Yu
- Beijing
National Laboratory for Molecular Sciences, Key Laboratory of Analytical
Chemistry for Living Biosystems, Institute
of Chemistry, Chinese Academy of Sciences, Beijing 100190, China
| | - Lanqun Mao
- College
of Chemistry, Beijing Normal University, Beijing 100875, China
| |
Collapse
|
9
|
Liu Y, Liu Z, Zhou Y, Tian Y. Implantable Electrochemical Sensors for Brain Research. JACS AU 2023; 3:1572-1582. [PMID: 37388703 PMCID: PMC10301805 DOI: 10.1021/jacsau.3c00200] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/20/2023] [Revised: 05/19/2023] [Accepted: 05/22/2023] [Indexed: 07/01/2023]
Abstract
Implantable electrochemical sensors provide reliable tools for in vivo brain research. Recent advances in electrode surface design and high-precision fabrication of devices led to significant developments in selectivity, reversibility, quantitative detection, stability, and compatibility of other methods, which enabled electrochemical sensors to provide molecular-scale research tools for dissecting the mechanisms of the brain. In this Perspective, we summarize the contribution of these advances to brain research and provide an outlook on the development of the next generation of electrochemical sensors for the brain.
Collapse
Affiliation(s)
- Yuandong Liu
- Shanghai
Key Laboratory of Green Chemistry and Chemical Processes, Department
of Chemistry, School of Chemistry and Molecular Engineering, East China Normal University, Dongchuan Road 500, Shanghai 200241, People’s Republic of China
| | - Zhichao Liu
- Shanghai
Key Laboratory of Green Chemistry and Chemical Processes, Department
of Chemistry, School of Chemistry and Molecular Engineering, East China Normal University, Dongchuan Road 500, Shanghai 200241, People’s Republic of China
| | - Yi Zhou
- School
of Basic Medical Sciences, Chengdu University
of Traditional Chinese Medicine, Sichuan 611137, People’s Republic of China
| | - Yang Tian
- Shanghai
Key Laboratory of Green Chemistry and Chemical Processes, Department
of Chemistry, School of Chemistry and Molecular Engineering, East China Normal University, Dongchuan Road 500, Shanghai 200241, People’s Republic of China
| |
Collapse
|
10
|
Wei H, Li L, Xue Y, Yu P, Mao L. Stability Enhancement of Galvanic Redox Potentiometry by Optimizing the Redox Couple in Counterpart Poles. Anal Chem 2023; 95:8232-8238. [PMID: 37201512 DOI: 10.1021/acs.analchem.3c00110] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
Potentiometry based on the galvanic cell mechanism, i.e., galvanic redox potentiometry (GRP), has recently emerged as a new tool for in vivo neurochemical sensing with high neuronal compatibility and good sensing property. However, the stability of open circuit voltage (EOC) outputting remains to be further improved for in vivo sensing application. In this study, we find that the EOC stability could be enhanced by adjusting the sort and the concentration ratio of the redox couple in the counterpart pole (i.e., indicating electrode) of GRP. With dopamine (DA) as the sensing target, we construct a spontaneously powered single-electrode-based GRP sensor (GRP2.0) and investigate the correlation between the stability and the redox couple used in the counterpart pole. Theoretical consideration suggests that the EOC drift is minimum when the concentration ratio of the oxidized form (O1) to the reduced form (R1) of the redox species in the backfilled solution is 1:1. The experimental results demonstrate that, compared with other redox species (i.e., dissolved O2 at 3 M KCl, potassium ferricyanide (K3Fe(CN)6), and hexaammineruthenium(III) chloride (Ru(NH3)6Cl3)) used as the counterpart pole, potassium hexachloroiridate(IV) (K2IrCl6) exhibits better chemical stability and outputs more stable EOC. As a result, when IrCl62-/3- with the concentration ratio of 1:1 is used as the counterpart, GRP2.0 displays not only an excellent EOC stability (i.e., 3.8 mV drifting during 2200 s for in vivo recording) but also small electrode-to-electrode variation (i.e., the maximum EOC variation between four electrodes is 2.7 mV). Upon integration with the electrophysiology, GRP2.0 records a robust DA release, accompanied by a burst of neural firing, during the optical stimulation. This study paves a new avenue to stable neurochemical sensing in vivo.
Collapse
Affiliation(s)
- Huan Wei
- College of Chemistry, Beijing Normal University, Beijing 100875, China
| | - Lijuan Li
- Department of Otorhinolaryngology, Peking University Third Hospital, Beijing 100191, China
| | - Yifei Xue
- College of Chemistry, Beijing Normal University, Beijing 100875, China
| | - Ping Yu
- Beijing National Laboratory for Molecular Sciences, Key Laboratory of Analytical Chemistry for Living Biosystems, Institute of Chemistry, The Chinese Academy of Sciences, Beijing 100190, China
- University of Chinese Academy of Sciences, Beijing 100049, China
| | - Lanqun Mao
- College of Chemistry, Beijing Normal University, Beijing 100875, China
| |
Collapse
|
11
|
Cho W, Yoon SH, Chung TD. Streamlining the interface between electronics and neural systems for bidirectional electrochemical communication. Chem Sci 2023; 14:4463-4479. [PMID: 37152246 PMCID: PMC10155913 DOI: 10.1039/d3sc00338h] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2023] [Accepted: 04/13/2023] [Indexed: 05/09/2023] Open
Abstract
Seamless neural interfaces conjoining neurons and electrochemical devices hold great potential for highly efficient signal transmission across neural systems and the external world. Signal transmission through chemical sensing and stimulation via electrochemistry is remarkable because communication occurs through the same chemical language of neurons. Emerging strategies based on synaptic interfaces, iontronics-based neuromodulation, and improvements in selective neurosensing techniques have been explored to achieve seamless integration and efficient neuro-electronics communication. Synaptic interfaces can directly exchange signals to and from neurons, in a similar manner to that of chemical synapses. Hydrogel-based iontronic chemical delivery devices are operationally compatible with neural systems for improved neuromodulation. In this perspective, we explore developments to improve the interface between neurons and electrodes by targeting neurons or sub-neuronal regions including synapses. Furthermore, recent progress in electrochemical neurosensing and iontronics-based chemical delivery is examined.
Collapse
Affiliation(s)
- Wonkyung Cho
- Department of Chemistry, Seoul National University Seoul 08826 Republic of Korea
| | - Sun-Heui Yoon
- Department of Chemistry, Seoul National University Seoul 08826 Republic of Korea
| | - Taek Dong Chung
- Department of Chemistry, Seoul National University Seoul 08826 Republic of Korea
- Advanced Institutes of Convergence Technology Suwon-si 16229 Gyeonggi-do Republic of Korea
| |
Collapse
|
12
|
Zhu F, Xue Y, Ji W, Li X, Ma W, Yu P, Jiang Y, Mao L. Galvanic Redox Potentiometry for Fouling-Free and Stable Serotonin Sensing in a Living Animal Brain. Angew Chem Int Ed Engl 2023; 62:e202212458. [PMID: 36688872 DOI: 10.1002/anie.202212458] [Citation(s) in RCA: 10] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2022] [Revised: 12/30/2022] [Accepted: 01/23/2023] [Indexed: 01/24/2023]
Abstract
Serotonin (5-HT) is a major neurotransmitter broadly involved in many aspects of feeling and behavior. Although its electro-activity makes it a promising candidate for electrochemical sensing, the persistent generation of fouling layers on the electrode by its oxidation products presents a hurdle for reliable sensing. Here, we present a fouling-free 5-HT sensor based on galvanic redox potentiometry. The sensor efficiently minimizes electrode fouling as revealed by in situ Raman spectroscopy, ensuring a less than 3 % signal change in a 2 hour continuous experiment, whereas amperometric sensors losing 90 % within 30 min. Most importantly, the sensor is highly amenable for in vivo studies, permitting real-time 5-HT monitoring, and supporting the mechanism associated with serotonin release in brain. Our system offers an effective way for sensing different neurochemicals having significant fouling issues, thus facilitating the molecular-level understanding of brain function.
Collapse
Affiliation(s)
- Fenghui Zhu
- College of Chemistry, Beijing Normal University, Beijing, 100875, China
| | - Yifei Xue
- College of Chemistry, Beijing Normal University, Beijing, 100875, China
| | - Wenliang Ji
- College of Chemistry, Beijing Normal University, Beijing, 100875, China
| | - Xin Li
- College of Chemistry, Beijing Normal University, Beijing, 100875, China
| | - Wenjie Ma
- Beijing National Laboratory for Molecular Sciences, Key Laboratory of Analytical Chemistry for Living Biosystems, Institute of Chemistry, Chinese Academy of Sciences (CAS), Beijing, 100190, China.,University of Chinese Academy of Sciences, Beijing, 100049, China
| | - Ping Yu
- Beijing National Laboratory for Molecular Sciences, Key Laboratory of Analytical Chemistry for Living Biosystems, Institute of Chemistry, Chinese Academy of Sciences (CAS), Beijing, 100190, China.,University of Chinese Academy of Sciences, Beijing, 100049, China
| | - Ying Jiang
- College of Chemistry, Beijing Normal University, Beijing, 100875, China
| | - Lanqun Mao
- College of Chemistry, Beijing Normal University, Beijing, 100875, China
| |
Collapse
|
13
|
Ren G, Lu M, Zhao Z, Qin F, Li K, Chen W, Lin Y. Cobalt Single-Atom Nanozyme Co-Administration with Ascorbic Acid Enables Redox Imbalance for Tumor Catalytic Ablation. ACS Biomater Sci Eng 2023; 9:1066-1076. [PMID: 36617740 DOI: 10.1021/acsbiomaterials.2c01301] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
Abstract
The elevated antioxidant defense system in cancer cells can lead to resistance to treatments involving ROS. Breaking the redox balance of the cell system through a "open up the source and regulate the flow" strategy can inhibit the growth of cancer cells and thus design a cancer treatment strategy. Here, cobalt single atom-supported N-doped carbon nanozymes (Co SA-N/C) were synthesized via a simple sacrificial template method, which can mimic the properties of ascorbate oxidase and glutathione oxidase effectively. The synthesized Co SA-N/C can induce the generation of active oxygen by accelerating the oxidation of ascorbic acid (AA) and destroy the endogenous active oxygen scavenging system by consuming the main antioxidant, glutathione (GSH). In-depth in vitro and in vivo investigations indicate that compared with solo therapy, Co SA-N/C together with AA can significantly enhance the anti-tumor efficiency by simultaneously elevating oxidative stress and consuming the overexpressed glutathione (GSH) through the redox reaction catalyzed by Co SA-N/C. This work provides a promising route for developing nanozyme-guided and ascorbate-based antitumor agents.
Collapse
Affiliation(s)
- Guoyuan Ren
- Department of Chemistry, Capital Normal University, Beijing 100048, China
| | - Mingju Lu
- Department of Chemistry, Capital Normal University, Beijing 100048, China
| | - Zhiqiang Zhao
- Department of Chemistry, Capital Normal University, Beijing 100048, China
| | - Fengjuan Qin
- Beijing Key Laboratory of Construction Tailorable Advanced Functional Materials and Green Applications, School of Materials Science and Engineering, Beijing Institute of Technology, Beijing 100081, China
| | - Kai Li
- Department of Chemistry, Capital Normal University, Beijing 100048, China
| | - Wenxing Chen
- Beijing Key Laboratory of Construction Tailorable Advanced Functional Materials and Green Applications, School of Materials Science and Engineering, Beijing Institute of Technology, Beijing 100081, China
| | - Yuqing Lin
- Department of Chemistry, Capital Normal University, Beijing 100048, China
| |
Collapse
|
14
|
Yin Y, Zeng H, Wang HM, Zhang M. Biocompatible Microelectrode for In Vivo Sensing with Improved Performance. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2023; 39:1719-1729. [PMID: 36689914 DOI: 10.1021/acs.langmuir.2c03267] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/17/2023]
Abstract
In vivo sensing based on implantable microelectrodes has been widely used to monitor neurochemicals due to its high spatial and temporal resolution and engineering interface designability, which has become a powerful drive to decode the mysteries of degenerative diseases and regulate neural activity. Over the past few decades, with the development of a variety of advanced materials and technologies, encouraging progress has been made in quantifying various neurochemical transients. However, because of the complex chemical atmosphere including thousands of small and large biomolecules and the inherent low mechanical property of brain tissue, the design of a compatible microelectrode for the in vivo electrochemical tracking of neurochemicals with high selectivity and stability still faces great challenges. This Perspective presents a brief account of recent representative progress in the rational regulation of the microelectrode interface to resolve the questions of selectivity and sensitive decrease resulting from antiprotein adsorption, and how to decrease the mechanical mismatch of an implanted electrode with that of brain tissue. Possible future research directions on further addressing the above key issues and a more biocompatible microelectrode for in vivo long-time electrochemical analysis are also discussed.
Collapse
Affiliation(s)
- Yongyue Yin
- Department of Chemistry, Renmin University of China, Beijing 100872, P. R. China
| | - Hui Zeng
- Department of Chemistry, Renmin University of China, Beijing 100872, P. R. China
| | - Hui-Ming Wang
- Department of Chemistry, Renmin University of China, Beijing 100872, P. R. China
| | - Meining Zhang
- Department of Chemistry, Renmin University of China, Beijing 100872, P. R. China
| |
Collapse
|
15
|
Wu F, Yu P, Mao L. Multi-Spatiotemporal Probing of Neurochemical Events by Advanced Electrochemical Sensing Methods. Angew Chem Int Ed Engl 2023; 62:e202208872. [PMID: 36284258 DOI: 10.1002/anie.202208872] [Citation(s) in RCA: 20] [Impact Index Per Article: 20.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2022] [Indexed: 11/05/2022]
Abstract
Neurochemical events involving biosignals of different time and space dimensionalities constitute the complex basis of neurological functions and diseases. In view of this fact, electrochemical measurements enabling real-time quantification of neurochemicals at multiple levels of spatiotemporal resolution can provide informative clues to decode the molecular networks bridging vesicles and brains. This Minireview focuses on how scientific questions regarding the properties of single vesicles, neurotransmitter release kinetics, interstitial neurochemical dynamics, and multisignal interconnections in vivo have driven the design of electrochemical nano/microsensors, sensing interface engineering, and signal/data processing. An outlook for the future frontline in this realm will also be provided.
Collapse
Affiliation(s)
- Fei Wu
- College of Chemistry, Beijing Normal University, Beijing, 100875, China.,Beijing National Laboratory for Molecular Sciences, Key Laboratory of Analytical Chemistry for Living Biosystems, Institute of Chemistry, Chinese Academy of Sciences, Beijing, 100190, China
| | - Ping Yu
- Beijing National Laboratory for Molecular Sciences, Key Laboratory of Analytical Chemistry for Living Biosystems, Institute of Chemistry, Chinese Academy of Sciences, Beijing, 100190, China.,University of Chinese Academy of Sciences, Beijing, 100049, China
| | - Lanqun Mao
- College of Chemistry, Beijing Normal University, Beijing, 100875, China
| |
Collapse
|
16
|
Zheng X, Liu J, Li M, Hua Y, Liang X, Zhang S, Zhang X, Shao Y. Dual-Nanopipettes for the Detection of Single Nanoparticles and Small Molecules. Anal Chem 2022; 94:17431-17438. [PMID: 36495265 DOI: 10.1021/acs.analchem.2c03344] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Nanopore sensing is blooming due to its label-free and high sensitivity features. As a novel nanopore, a droplet is formed at the orifice of a dual-nanopipette, which allows for the translocation of analytes through the two channels at a relatively low speed and the promotion of signal-to-noise ratio. However, nanopore sensing based on the principle of current blockage requires the pore size to be comparable to that of the single entity, which poses a huge challenge for the direct detection of small molecules. In this work, gold nanoparticles (Au NPs) modified with sulfhydryl poly(ethylene glycol) (PEG-SH) or aptamers were detected successfully. The size difference of Au NPs and the interaction between Au NPs and dual-nanopipettes could be distinguished sensitively. Furthermore, Au NPs modified with designed aptamers will produce different blocking current after capturing the corresponding small molecules (e.g., dopamine and serotonin). Even non-electroactive ions, such as potassium ions, can also be detected, which is difficult to sense based on redox reactions, and further illustrates that the change of surface properties of nanoparticles is responsible for the detection. This work expands the application of nanopipette sensing for Au NPs and provides a universal platform for the small-molecule detection, which has the potential application in biosensing.
Collapse
Affiliation(s)
- Xinhe Zheng
- Beijing National Laboratory for Molecular Sciences, College of Chemistry and Molecular Engineering, Peking University, Beijing 100871, China
| | - Junjie Liu
- Beijing National Laboratory for Molecular Sciences, College of Chemistry and Molecular Engineering, Peking University, Beijing 100871, China
| | - Mingzhi Li
- Beijing National Laboratory for Molecular Sciences, College of Chemistry and Molecular Engineering, Peking University, Beijing 100871, China
| | - Yutong Hua
- Beijing National Laboratory for Molecular Sciences, College of Chemistry and Molecular Engineering, Peking University, Beijing 100871, China
| | - Xu Liang
- Beijing National Laboratory for Molecular Sciences, College of Chemistry and Molecular Engineering, Peking University, Beijing 100871, China
| | - Shudong Zhang
- Beijing National Laboratory for Molecular Sciences, College of Chemistry and Molecular Engineering, Peking University, Beijing 100871, China
| | - Xianhao Zhang
- Beijing National Laboratory for Molecular Sciences, College of Chemistry and Molecular Engineering, Peking University, Beijing 100871, China
| | - Yuanhua Shao
- Beijing National Laboratory for Molecular Sciences, College of Chemistry and Molecular Engineering, Peking University, Beijing 100871, China
| |
Collapse
|
17
|
Yi D, Hartner JP, Ung BS, Zhu HL, Watson BO, Chen L. 3D Printed Skull Cap and Benchtop Fabricated Microwire-Based Microelectrode Array for Custom Rat Brain Recordings. Bioengineering (Basel) 2022; 9:bioengineering9100550. [PMID: 36290518 PMCID: PMC9598465 DOI: 10.3390/bioengineering9100550] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2022] [Revised: 10/05/2022] [Accepted: 10/08/2022] [Indexed: 11/16/2022] Open
Abstract
Microwire microelectrode arrays (MEAs) have been a popular low-cost tool for chronic electrophysiological recordings and are an inexpensive means to record the electrical dynamics crucial to brain function. However, both the fabrication and implantation procedures for multi-MEAs on a single rodent are time-consuming and the accuracy and quality are highly manual skill-dependent. To address the fabrication and implantation challenges for microwire MEAs, (1) a computer-aided designed and 3D printed skull cap for the pre-determined implantation locations of each MEA and (2) a benchtop fabrication approach for low-cost custom microwire MEAs were developed. A proof-of-concept design of a 32-channel 4-MEA (8-wire each) recording system was prototyped and tested through Sprague Dawley rat recordings. The skull cap design, based on the CT-scan of a single rat conforms well with multiple Sprague Dawley rats of various sizes, ages, and weight with a minimal bregma alignment error (A/P axis standard error of the mean = 0.25 mm, M/L axis standard error of the mean = 0.07 mm, n = 6). The prototyped 32-channel system was able to record the spiking activities over five months. The developed benchtop fabrication method and the 3D printed skull cap implantation platform would enable neuroscience groups to conduct in-house design, fabrication, and implantation of customizable microwire MEAs at a lower cost than the current commercial options and experience a shorter lead time for the design modifications and iterations.
Collapse
Affiliation(s)
- Dongyang Yi
- Department of Mechanical Engineering, University of Massachusetts Lowell, Lowell, MA 01854, USA
| | | | - Brian S. Ung
- Department of Mechanical Engineering, University of Massachusetts Lowell, Lowell, MA 01854, USA
| | - Harrison L. Zhu
- Department of Mechanical Engineering, University of Massachusetts Lowell, Lowell, MA 01854, USA
| | - Brendon O. Watson
- Department of Psychiatry, University of Michigan, Ann Arbor, MI 48109, USA
| | - Lei Chen
- Department of Mechanical Engineering, University of Massachusetts Lowell, Lowell, MA 01854, USA
- Department of Psychiatry, University of Michigan, Ann Arbor, MI 48109, USA
- Correspondence:
| |
Collapse
|
18
|
Qu ZB, Jiang Y, Zhang J, Chen S, Zeng R, Zhuo Y, Lu M, Shi G, Gu H. Tailoring Oxygen-Containing Groups on Graphene for Ratiometric Electrochemical Measurements of Ascorbic Acid in Living Subacute Parkinson's Disease Mouse Brains. Anal Chem 2021; 93:16598-16607. [PMID: 34844405 DOI: 10.1021/acs.analchem.1c03965] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
Ascorbic acid (AA), a major antioxidant in the central nervous system (CNS), is involved in withstanding oxidative stress that plays a significant role in the pathogenesis of Parkinson's disease (PD). Exploring the AA disturbance in the process of PD is of great value in understanding the molecular mechanism of PD. Herein, by virtue of a carbon fiber electrode (CFE) as a matric electrode, a three-step electrochemical process for tailoring oxygen-containing groups on graphene was well designed: potentiostatic deposition was carried out to fabricate graphene oxide on CFE, electrochemical reduction that assisted in removing the epoxy groups accelerated the electron transfer kinetics of AA oxidation, and electrochemical oxidation that increased the content of the carbonyl group (C═O) generated an inner-reference signal. The mechanism was solidified by ab initio calculations by comparing AA absorption on defected models of graphene functionalized with different oxygen groups including carboxyl, hydroxyl, epoxy, and carbonyl. It was found that epoxy groups would hinder the physical absorption of AA onto graphene, while other functional groups would be beneficial to it. Biocompatible polyethylenedioxythiophene (PEDOT) was further rationally assembled to improve the antifouling property of graphene. As a result, a new platform for ratiometric electrochemical measurements of AA with high sensitivity, excellent selectivity, and reproducibility was established. In vivo determination of AA levels in different regions of living mouse brains by the proposed method demonstrated that AA decreased remarkably in the hippocampus and cortex of a subacute PD mouse than those of a normal mouse.
Collapse
Affiliation(s)
- Zhi-Bei Qu
- Department of Medicinal Chemistry, School of Pharmacy, Fudan University, Shanghai 201203, China
| | - Yimin Jiang
- School of Chemistry and Chemical Engineering, Hunan University of Science and Technology, Xiangtan, Hunan 411201, P. R. China
| | - Jiaxin Zhang
- School of Chemistry and Chemical Engineering, Hunan University of Science and Technology, Xiangtan, Hunan 411201, P. R. China
| | - Shu Chen
- School of Chemistry and Chemical Engineering, Hunan University of Science and Technology, Xiangtan, Hunan 411201, P. R. China
| | - Rongjin Zeng
- School of Chemistry and Chemical Engineering, Hunan University of Science and Technology, Xiangtan, Hunan 411201, P. R. China
| | - Yi Zhuo
- Hunan Provincial Key Laboratory of Neurorestoratology, College of Life Sciences, Hunan Normal University, Changsha, Hunan 410006, P.R. China
| | - Ming Lu
- Hunan Provincial Key Laboratory of Neurorestoratology, College of Life Sciences, Hunan Normal University, Changsha, Hunan 410006, P.R. China
| | - Guoyue Shi
- School of Chemistry and Molecular Engineering, Shanghai Key Laboratory for Urban Ecological Processes and Eco-Restoration, East China Normal University, Shanghai 200241, P. R. China
| | - Hui Gu
- School of Chemistry and Chemical Engineering, Hunan University of Science and Technology, Xiangtan, Hunan 411201, P. R. China
| |
Collapse
|
19
|
Rafi H, Zestos AG. Multiplexing neurochemical detection with carbon fiber multielectrode arrays using fast-scan cyclic voltammetry. Anal Bioanal Chem 2021; 413:6715-6726. [PMID: 34259877 PMCID: PMC8551007 DOI: 10.1007/s00216-021-03526-x] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2021] [Revised: 06/28/2021] [Accepted: 07/01/2021] [Indexed: 10/20/2022]
Abstract
Carbon fiber microelectrodes (CFMEs) have been extensively used to measure neurotransmitters with fast-scan cyclic voltammetry (FSCV) due to their ability to adsorb cationic monoamine neurotransmitters. Although FSCV, in tandem with CFMEs, provides high temporal and spatial resolution, only single-channel potentiostats and electrodes have been primarily utilized. More recently, the need and use of carbon fiber multielectrode arrays has risen to target multiple brain regions. Previous studies have shown the ability to detect dopamine using multielectrode arrays; however, they are not readily available to the scientific community. In this work, we interfaced a carbon fiber multielectrode array (MEA or multielectrode array), to a commercially available four-channel potentiostat for multiplexing neurochemical measurements. The MEA's relative performance was compared to single CFMEs where dopamine detection was found to be adsorption controlled to the electrode's surface. Multiple waveforms were applied to each fiber of the multielectrode array simultaneously to detect different analytes on each electrode of the array. A proof of concept ex vivo experiment showed that the multielectrode array could record redox activity in different areas within the mouse caudate putamen and detect dopamine in a 3-mm2 area. To our knowledge, this is the first use of the multielectrode array paired with a commercially available multichannel potentiostat for multi-waveform application and neurotransmitter co-detection. This novel array may aid in future studies to better understand complex brain heterogeneity, the dynamic neurochemical environment, and how disease states or drugs affect separate brain areas concurrently. Graphical abstract.
Collapse
Affiliation(s)
- Harmain Rafi
- Center for Neuroscience and Behavior, American University, Washington, DC, 20016, USA
- Department of Neuroscience, American University, Washington, DC, 20016, USA
| | - Alexander G Zestos
- Center for Neuroscience and Behavior, American University, Washington, DC, 20016, USA.
- Department of Chemistry, American University, Washington, DC, 20016, USA.
| |
Collapse
|
20
|
Li C, Zhuo Y, Xiao X, Li S, Han K, Lu M, Zhang J, Chen S, Gu H. Facile Electrochemical Microbiosensor Based on In Situ Self-Assembly of Ag Nanoparticles Coated on Ti 3C 2T x for In Vivo Measurements of Chloride Ions in the PD Mouse Brain. Anal Chem 2021; 93:7647-7656. [PMID: 34014093 DOI: 10.1021/acs.analchem.1c00342] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Chloride ion (Cl-), one of the most important anions in the brain, has been confirmed to participate in the pathological process of Parkinson's disease (PD). As such, the development of a reliable method for in vivo measurements of Cl- is extremely appealing, especially for understanding the pathogenesis of PD. We herein designed a facile electrochemical microbiosensor (ECMB), based on in situ self-assembly of Ag nanoparticles (Ag NPs) coated on Ti3C2Tx. The uniform nanosized Ag NPs were reduced by Ti3C2Tx by a simple dipping process, endowing the ECMB with excellent specificity toward Cl- detection and remarkably reproducible preparation process. Meanwhile, electro-oxidized graphene oxide was introduced as an inner reference, thus avoiding the environmental interference of the complicated brain systems to increase the determination accuracy. An extensive in vitro study revealed that the proposed ECMB would be a robust candidate for real-time monitoring of Cl- in the PD mouse brain with high selectivity, accuracy, and reproducibility. Moreover, the availability and reliability toward in vivo Cl- monitoring of the designed ECMB were well confirmed by comparing with the standard Volhard's method. Finally, by virtue of the successful employment of the developed detecting platform in the in vivo measurement of Cl- in the PD mouse brain, systematic analysis and comparison of the average levels of Cl- in the three regions including cortex, striatum, and hippocampus of brains from normal and PD model mice have been achieved.
Collapse
Affiliation(s)
- Chenchen Li
- A Key Laboratory of Theoretical Organic Chemistry and Functional Molecule of Ministry of Education, School of Chemistry and Chemical Engineering, Hunan University of Science and Technology, Xiangtan, Hunan 411201, P. R. China
| | - Yi Zhuo
- The National & Local Joint Engineering Laboratory of Animal Peptide Drug Development, Hunan Provincical Key Laboratory of Neurorestoratology, College of Life Sciences, Hunan Normal University, Changsha, Hunan 410006, P. R. China
| | - Xia Xiao
- A Key Laboratory of Theoretical Organic Chemistry and Functional Molecule of Ministry of Education, School of Chemistry and Chemical Engineering, Hunan University of Science and Technology, Xiangtan, Hunan 411201, P. R. China
| | - Shuangfu Li
- College of Chemistry and Chemical Engineering, Central South University, Changsha, Hunan 410083, P. R. China
| | - Kai Han
- College of Chemistry and Chemical Engineering, Central South University, Changsha, Hunan 410083, P. R. China
| | - Ming Lu
- The National & Local Joint Engineering Laboratory of Animal Peptide Drug Development, Hunan Provincical Key Laboratory of Neurorestoratology, College of Life Sciences, Hunan Normal University, Changsha, Hunan 410006, P. R. China
| | - Jiaxin Zhang
- A Key Laboratory of Theoretical Organic Chemistry and Functional Molecule of Ministry of Education, School of Chemistry and Chemical Engineering, Hunan University of Science and Technology, Xiangtan, Hunan 411201, P. R. China
| | - Shu Chen
- A Key Laboratory of Theoretical Organic Chemistry and Functional Molecule of Ministry of Education, School of Chemistry and Chemical Engineering, Hunan University of Science and Technology, Xiangtan, Hunan 411201, P. R. China
| | - Hui Gu
- A Key Laboratory of Theoretical Organic Chemistry and Functional Molecule of Ministry of Education, School of Chemistry and Chemical Engineering, Hunan University of Science and Technology, Xiangtan, Hunan 411201, P. R. China
| |
Collapse
|
21
|
Zhang L, Xu T, Ji W, Wang X, Cheng S, Zhang S, Zhang Y, Zhang M. Ag 2S/Ag Nanoparticle Microelectrodes for In Vivo Potentiometric Measurement of Hydrogen Sulfide Dynamics in the Rat Brain. Anal Chem 2021; 93:7063-7070. [PMID: 33900732 DOI: 10.1021/acs.analchem.1c00540] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Hydrogen sulfide (H2S) plays a pivotal role in gas signal transduction, neuroprotection, and regulation of physiological and pathological processes. However, in vivo tracking the dynamic of hydrogen sulfide in the complex brain environment still faces huge challenges. This study demonstrates a new potentiometric method to monitor in vivo the dynamics of hydrogen sulfide in the rat brain using silver nanoparticles (AgNPs)-modified carbon fiber microelectrodes (AgNPs/CFE) pretreated with Na2S (i.e., Ag2S/AgNPs/CFE), which acts as a solid-contact and ion-selective microelectrode. The Ag2S/AgNPs/CFE exhibits good potential response toward hydrogen sulfide in the range of 2.5-160 μM, with a detection limit of 0.8 μM. Because of the presence of Ag2S, the Ag2S/AgNPs/CFE shows good selectivity to hydrogen sulfide, avoiding the interference from coexistent electroactive neurochemicals and the analogies, such as ascorbic acid and cysteine in the central nervous system. This good selectivity combined with the reversibility, protein antifouling, and biocompatibility of the microelectrode enables the Ag2S/AgNPs/CFE to detect hydrogen sulfide in the rat brain during local microinfusion of Na2S and the change in pH. Our study provides a reliable method to track hydrogen sulfide selectively in vivo, which will help to explore the function of hydrogen sulfide in neurophysiology and pathology.
Collapse
Affiliation(s)
- Li Zhang
- Department of Chemistry, Renmin University of China, Beijing 100872, China
| | - Tianci Xu
- Department of Chemistry, Renmin University of China, Beijing 100872, China
| | - Wenliang Ji
- Department of Chemistry, Renmin University of China, Beijing 100872, China
| | - Xiaofang Wang
- Department of Chemistry, Renmin University of China, Beijing 100872, China
| | - Shuwen Cheng
- Department of Chemistry, Renmin University of China, Beijing 100872, China
| | - Shuai Zhang
- Department of Chemistry, Renmin University of China, Beijing 100872, China
| | - Yue Zhang
- Department of Chemistry, Renmin University of China, Beijing 100872, China
| | - Meining Zhang
- Department of Chemistry, Renmin University of China, Beijing 100872, China
| |
Collapse
|
22
|
Freeman CJ, Ullah B, Islam MS, Collinson MM. Potentiometric Biosensing of Ascorbic Acid, Uric Acid, and Cysteine in Microliter Volumes Using Miniaturized Nanoporous Gold Electrodes. BIOSENSORS-BASEL 2020; 11:bios11010010. [PMID: 33379137 PMCID: PMC7823660 DOI: 10.3390/bios11010010] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/06/2020] [Revised: 12/13/2020] [Accepted: 12/21/2020] [Indexed: 02/04/2023]
Abstract
Potentiometric redox sensing is a relatively inexpensive and passive approach to evaluate the overall redox state of complex biological and environmental solutions. The ability to make such measurements in ultra-small volumes using high surface area, nanoporous electrodes is of particular importance as such electrodes can improve the rates of electron transfer and reduce the effects of biofouling on the electrochemical signal. This work focuses on the fabrication of miniaturized nanoporous gold (NPG) electrodes with a high surface area and a small footprint for the potentiometric redox sensing of three biologically relevant redox molecules (ascorbic acid, uric acid, and cysteine) in microliter volumes. The NPG electrodes were inexpensively made by attaching a nanoporous gold leaf prepared by dealloying 12K gold in nitric acid to a modified glass capillary (1.5 mm id) and establishing an electrode connection with copper tape. The surface area of the electrodes was ~1.5 cm2, providing a roughness factor of ~16 relative to the geometric area of 0.09 cm2. Scanning electron microscopy confirmed the nanoporous framework. A linear dependence between the open-circuit potential (OCP) and the logarithm of concentration (e.g., Nernstian-like behavior) was obtained for all three redox molecules in 100 μL buffered solutions. As a first step towards understanding a real system, the response associated with changing the concentration of one redox species in the presence of the other two was examined. These results show that at NPG, the redox potential of a solution containing biologically relevant concentrations of ascorbic acid, uric acid, and cysteine is strongly influenced by ascorbic acid. Such information is important for the measurement of redox potentials in complex biological solutions.
Collapse
Affiliation(s)
- Christopher J. Freeman
- Department of Chemistry and Biochemistry, Old Dominion University, Norfolk, VA 23529, USA;
| | - Borkat Ullah
- Department of Chemistry, Virginia Commonwealth University, Richmond, VA 23284, USA; (B.U.); (M.S.I.)
| | - Md. Shafiul Islam
- Department of Chemistry, Virginia Commonwealth University, Richmond, VA 23284, USA; (B.U.); (M.S.I.)
| | - Maryanne M. Collinson
- Department of Chemistry, Virginia Commonwealth University, Richmond, VA 23284, USA; (B.U.); (M.S.I.)
- Correspondence:
| |
Collapse
|