1
|
Chapman M, Rajagopal V, Stewart A, Collins DJ. Critical review of single-cell mechanotyping approaches for biomedical applications. LAB ON A CHIP 2024; 24:3036-3063. [PMID: 38804123 DOI: 10.1039/d3lc00978e] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/29/2024]
Abstract
Accurate mechanical measurements of cells has the potential to improve diagnostics, therapeutics and advance understanding of disease mechanisms, where high-resolution mechanical information can be measured by deforming individual cells. Here we evaluate recently developed techniques for measuring cell-scale stiffness properties; while many such techniques have been developed, much of the work examining single-cell stiffness is impacted by difficulties in standardization and comparability, giving rise to large variations in reported mechanical moduli. We highlight the role of underlying mechanical theories driving this variability, and note opportunities to develop novel mechanotyping devices and theoretical models that facilitate convenient and accurate mechanical characterisation. Moreover, many high-throughput approaches are confounded by factors including cell size, surface friction, natural population heterogeneity and convolution of elastic and viscous contributions to cell deformability. We nevertheless identify key approaches based on deformability cytometry as a promising direction for further development, where both high-throughput and accurate single-cell resolutions can be realized.
Collapse
Affiliation(s)
- Max Chapman
- Department of Biomedical Engineering, University of Melbourne, Melbourne, Victoria, Australia.
| | - Vijay Rajagopal
- Department of Biomedical Engineering, University of Melbourne, Melbourne, Victoria, Australia.
| | - Alastair Stewart
- ARC Centre for Personalised Therapeutics Technologies, The University of Melbourne, Parkville, VIC, Australia
- Department of Biochemistry and Pharmacology, The University of Melbourne, Parkville, VIC, Australia
| | - David J Collins
- Department of Biomedical Engineering, University of Melbourne, Melbourne, Victoria, Australia.
- Graeme Clarke Institute University of Melbourne Parkville, Victoria 3052, Australia
| |
Collapse
|
2
|
Sehati M, Rafii-Tabar H, Sasanpour P. Computational modeling of the variation of the transmembrane potential of the endothelial cells of the blood-brain-barrier subject to an external electric field. Biomed Phys Eng Express 2023; 9:065009. [PMID: 37703844 DOI: 10.1088/2057-1976/acf937] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2023] [Accepted: 09/13/2023] [Indexed: 09/15/2023]
Abstract
The electromechanical properties of the membrane of endothelial cells forming the blood-brain barrier play a vital role in the function of this barrier. The mechanical effect exerted by external electric fields on the membrane could change its electrical properties. In this study the effect of extremely low frequency (ELF) external electric fields on the electrical activity of these cells has been studied by considering the mechanical effect of these fields on the capacitance of the membrane. The effect of time-dependent capacitance of the membrane is incorporated in the current components of the parallel conductance model for the electrical activity of the cells. The results show that the application of ELF electric fields induces hyperpolarization, having an indirect effect on the release of nitric oxide from the endothelial cell and the polymerization of actin filaments. Accordingly, this could play an important role in the permeability of the barrier. Our finding can have possible consequences in the field of drug delivery into the central nervous system.
Collapse
Affiliation(s)
- Mahboobe Sehati
- Department of Medical Physics and Biomedical Engineering, School of Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Hashem Rafii-Tabar
- Department of Medical Physics and Biomedical Engineering, School of Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iran
- The Physics Branch of the Academy of Sciences of Iran, Tehran, Iran
| | - Pezhman Sasanpour
- Department of Medical Physics and Biomedical Engineering, School of Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| |
Collapse
|
3
|
Raj M K, Priyadarshani J, Karan P, Bandyopadhyay S, Bhattacharya S, Chakraborty S. Bio-inspired microfluidics: A review. BIOMICROFLUIDICS 2023; 17:051503. [PMID: 37781135 PMCID: PMC10539033 DOI: 10.1063/5.0161809] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/12/2023] [Accepted: 09/01/2023] [Indexed: 10/03/2023]
Abstract
Biomicrofluidics, a subdomain of microfluidics, has been inspired by several ideas from nature. However, while the basic inspiration for the same may be drawn from the living world, the translation of all relevant essential functionalities to an artificially engineered framework does not remain trivial. Here, we review the recent progress in bio-inspired microfluidic systems via harnessing the integration of experimental and simulation tools delving into the interface of engineering and biology. Development of "on-chip" technologies as well as their multifarious applications is subsequently discussed, accompanying the relevant advancements in materials and fabrication technology. Pointers toward new directions in research, including an amalgamated fusion of data-driven modeling (such as artificial intelligence and machine learning) and physics-based paradigm, to come up with a human physiological replica on a synthetic bio-chip with due accounting of personalized features, are suggested. These are likely to facilitate physiologically replicating disease modeling on an artificially engineered biochip as well as advance drug development and screening in an expedited route with the minimization of animal and human trials.
Collapse
Affiliation(s)
- Kiran Raj M
- Department of Applied Mechanics and Biomedical Engineering, Indian Institute of Technology Madras, Chennai, Tamil Nadu 600036, India
| | - Jyotsana Priyadarshani
- Department of Mechanical Engineering, Biomechanics Section (BMe), KU Leuven, Celestijnenlaan 300, 3001 Louvain, Belgium
| | - Pratyaksh Karan
- Géosciences Rennes Univ Rennes, CNRS, Géosciences Rennes, UMR 6118, 35000 Rennes, France
| | - Saumyadwip Bandyopadhyay
- Advanced Technology Development Centre, Indian Institute of Technology Kharagpur, Kharagpur, West Bengal 721302, India
| | - Soumya Bhattacharya
- Achira Labs Private Limited, 66b, 13th Cross Rd., Dollar Layout, 3–Phase, JP Nagar, Bangalore, Karnataka 560078, India
| | - Suman Chakraborty
- Department of Mechanical Engineering, Indian Institute of Technology Kharagpur, Kharagpur, West Bengal 721302, India
| |
Collapse
|
4
|
Deivasigamani R, Mohd Maidin NN, Abdul Nasir NS, Abdulhameed A, Ahmad Kayani AB, Mohamed MA, Buyong MR. A correlation of conductivity medium and bioparticle viability on dielectrophoresis-based biomedical applications. Electrophoresis 2023; 44:573-620. [PMID: 36604943 DOI: 10.1002/elps.202200203] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2022] [Revised: 11/28/2022] [Accepted: 12/26/2022] [Indexed: 01/07/2023]
Abstract
Dielectrophoresis (DEP) bioparticle research has progressed from micro to nano levels. It has proven to be a promising and powerful cell manipulation method with an accurate, quick, inexpensive, and label-free technique for therapeutic purposes. DEP, an electrokinetic phenomenon, induces particle movement as a result of polarization effects in a nonuniform electrical field. This review focuses on current research in the biomedical field that demonstrates a practical approach to DEP in terms of cell separation, trapping, discrimination, and enrichment under the influence of the conductive medium in correlation with bioparticle viability. The current review aims to provide readers with an in-depth knowledge of the fundamental theory and principles of the DEP technique, which is influenced by conductive medium and to identify and demonstrate the biomedical application areas. The high conductivity of physiological fluids presents obstacles and opportunities, followed by bioparticle viability in an electric field elaborated in detail. Finally, the drawbacks of DEP-based systems and the outlook for the future are addressed. This article will aid in advancing technology by bridging the gap between bioscience and engineering. We hope the insights presented in this review will improve cell suspension medium and promote DEP-viable bioparticle manipulation for health-care diagnostics and therapeutics.
Collapse
Affiliation(s)
- Revathy Deivasigamani
- Institute of Microengineering and Nanoelectronics (IMEN), Universiti Kebangsaan Malaysia (UKM), Bangi, Selangor, Malaysia
| | - Nur Nasyifa Mohd Maidin
- Institute of Microengineering and Nanoelectronics (IMEN), Universiti Kebangsaan Malaysia (UKM), Bangi, Selangor, Malaysia
| | - Nur Shahira Abdul Nasir
- Institute of Microengineering and Nanoelectronics (IMEN), Universiti Kebangsaan Malaysia (UKM), Bangi, Selangor, Malaysia
| | | | - Aminuddin Bin Ahmad Kayani
- Functional Materials and Microsystems Research Group and the Micro Nano Research Facility, RMIT University, Melbourne, Australia.,ARC Research Hub for Connected Sensors for Health, RMIT University, Melbourne, Australia
| | - Mohd Ambri Mohamed
- Institute of Microengineering and Nanoelectronics (IMEN), Universiti Kebangsaan Malaysia (UKM), Bangi, Selangor, Malaysia
| | - Muhamad Ramdzan Buyong
- Institute of Microengineering and Nanoelectronics (IMEN), Universiti Kebangsaan Malaysia (UKM), Bangi, Selangor, Malaysia
| |
Collapse
|
5
|
Nawaz AA, Soteriou D, Xu CK, Goswami R, Herbig M, Guck J, Girardo S. Image-based cell sorting using focused travelling surface acoustic waves. LAB ON A CHIP 2023; 23:372-387. [PMID: 36620943 PMCID: PMC9844123 DOI: 10.1039/d2lc00636g] [Citation(s) in RCA: 8] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/11/2022] [Accepted: 11/21/2022] [Indexed: 05/27/2023]
Abstract
Sorting cells is an essential primary step in many biological and clinical applications such as high-throughput drug screening, cancer research and cell transplantation. Cell sorting based on their mechanical properties has long been considered as a promising label-free biomarker that could revolutionize the isolation of cells from heterogeneous populations. Recent advances in microfluidic image-based cell analysis combined with subsequent label-free sorting by on-chip actuators demonstrated the possibility of sorting cells based on their physical properties. However, the high purity of sorting is achieved at the expense of a sorting rate that lags behind the analysis throughput. Furthermore, stable and reliable system operation is an important feature in enabling the sorting of small cell fractions from a concentrated heterogeneous population. Here, we present a label-free cell sorting method, based on the use of focused travelling surface acoustic wave (FTSAW) in combination with real-time deformability cytometry (RT-DC). We demonstrate the flexibility and applicability of the method by sorting distinct blood cell types, cell lines and particles based on different physical parameters. Finally, we present a new strategy to sort cells based on their mechanical properties. Our system enables the sorting of up to 400 particles per s. Sorting is therefore possible at high cell concentrations (up to 36 million per ml) while retaining high purity (>92%) for cells with diverse sizes and mechanical properties moving in a highly viscous buffer. Sorting of small cell fraction from a heterogeneous population prepared by processing of small sample volume (10 μl) is also possible and here demonstrated by the 667-fold enrichment of white blood cells (WBCs) from raw diluted whole blood in a continuous 10-hour sorting experiment. The real-time analysis of multiple parameters together with the high sensitivity and high-throughput of our method thus enables new biological and therapeutic applications in the future.
Collapse
Affiliation(s)
- Ahmad Ahsan Nawaz
- Max Planck Institute for the Science of Light & Max-Planck-Zentrum für Physik und Medizin, Erlangen, Germany.
| | - Despina Soteriou
- Max Planck Institute for the Science of Light & Max-Planck-Zentrum für Physik und Medizin, Erlangen, Germany.
| | - Catherine K Xu
- Max Planck Institute for the Science of Light & Max-Planck-Zentrum für Physik und Medizin, Erlangen, Germany.
| | - Ruchi Goswami
- Max Planck Institute for the Science of Light & Max-Planck-Zentrum für Physik und Medizin, Erlangen, Germany.
| | - Maik Herbig
- Department of Chemistry, University of Tokyo, Tokyo, Japan
| | - Jochen Guck
- Max Planck Institute for the Science of Light & Max-Planck-Zentrum für Physik und Medizin, Erlangen, Germany.
| | - Salvatore Girardo
- Max Planck Institute for the Science of Light & Max-Planck-Zentrum für Physik und Medizin, Erlangen, Germany.
| |
Collapse
|
6
|
Zaman MA, Padhy P, Wu M, Ren W, Jensen MA, Davis RW, Hesselink L. Controlled Transport of Individual Microparticles Using Dielectrophoresis. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2023; 39:101-110. [PMID: 36541659 PMCID: PMC10516752 DOI: 10.1021/acs.langmuir.2c02235] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/17/2023]
Abstract
A dielectrophoretic device employing a planar array of microelectrodes is designed for controlled transport of individual microparticles. By exciting the electrodes in sequence, a moving dielectrophoretic force is created that can drag a particle across the electrodes in a straight line. The electrode shapes are designed to counter any lateral drift of the trapped particle during transport. This facilitates single particle transport by creating a narrow two-dimensional corridor for the moving dielectrophoretic force to operate on. The design and analysis processes are discussed in detail. Numerical simulations are performed to calculate the electromagnetic field distribution and the generated dielectrophoretic force near the electrodes. The Langevin equation is used for analyzing the trajectory of a microparticle under the influence of the external forces. The simulations show how the designed electrode geometry produces the necessary lateral confinement required for successful particle transport. Finally, experimental results are presented showing controlled bidirectional linear transport of single polystyrene beads of radius 10 and 5 μm for a distances 840 and 1100 μm, respectively. The capabilities of the proposed platform make it suitable for micro total analysis systems (μTAS) and lab-on-a-chip (LOC) applications.
Collapse
Affiliation(s)
- Mohammad Asif Zaman
- Department of Electrical Engineering, Stanford University, Stanford, California94305, United States
| | - Punnag Padhy
- Department of Electrical Engineering, Stanford University, Stanford, California94305, United States
| | - Mo Wu
- Department of Electrical Engineering, Stanford University, Stanford, California94305, United States
| | - Wei Ren
- Department of Electrical Engineering, Stanford University, Stanford, California94305, United States
| | - Michael Anthony Jensen
- Department of Biochemistry, Stanford University, Stanford, California94305, United States
| | - Ronald W Davis
- Department of Biochemistry, Stanford University, Stanford, California94305, United States
| | - Lambertus Hesselink
- Department of Electrical Engineering, Stanford University, Stanford, California94305, United States
| |
Collapse
|
7
|
Yang J, Gu Y, Zhang C, Zhang Y, Liang W, Hao L, Zhao Y, Liu L, Wang W. Label-free purification and characterization of optogenetically engineered cells using optically-induced dielectrophoresis. LAB ON A CHIP 2022; 22:3687-3698. [PMID: 35903981 DOI: 10.1039/d2lc00512c] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Optogenetically engineered cell population obtained by heterogeneous gene expression plays a vital role in life science, medicine, and biohybrid robotics, and purification and characterization are essential to enhance its application performance. However, the existing cell purification methods suffer from complex sample preparation or inevitable damage and pollution. The efficient and nondestructive label-free purification and characterization of the optogenetically engineered cells, HEK293-ChR2 cells, is provided here using an optically-induced dielectrophoresis (ODEP)-based approach. The distinctive crossover frequencies of the engineered cells and the unmodified cells enable effective separation due to the opposite DEP forces on them. The ODEP-based approach can greatly improve the purity of the separated cell population and especially, the ratio of the engineered cells in the separated cell population can be enhanced by 275% at a low transfection rate. The size and the membrane capacitance of the separated cell population decreases and increases, respectively, as the ratio of the engineered cells grows in the cell population, indicating that successful expression of ChR2 in a single HEK293 cell makes its size and membrane capacitance smaller and larger, respectively. The results of biohybrid imaging with the optogenetically engineered cells demonstrated that cell purification can improve the imaging quality. This work proves that the separation and purification of engineered cells are of great significance for their application in practice.
Collapse
Affiliation(s)
- Jia Yang
- State Key Laboratory of Robotics, Shenyang Institute of Automation, Chinese Academy of Sciences, Shenyang 110016, China.
- Institutes for Robotics and Intelligent Manufacturing, Chinese Academy of Sciences, Shenyang 110169, China
- University of Chinese Academy of Sciences, Beijing 100049, China
| | - Yanyu Gu
- State Key Laboratory of Robotics, Shenyang Institute of Automation, Chinese Academy of Sciences, Shenyang 110016, China.
- Institutes for Robotics and Intelligent Manufacturing, Chinese Academy of Sciences, Shenyang 110169, China
- School of Mechanical Engineering and Automation, Northeastern University, Shenyang 110819, China.
| | - Chuang Zhang
- State Key Laboratory of Robotics, Shenyang Institute of Automation, Chinese Academy of Sciences, Shenyang 110016, China.
- Institutes for Robotics and Intelligent Manufacturing, Chinese Academy of Sciences, Shenyang 110169, China
| | - Yuzhao Zhang
- State Key Laboratory of Robotics, Shenyang Institute of Automation, Chinese Academy of Sciences, Shenyang 110016, China.
- Institutes for Robotics and Intelligent Manufacturing, Chinese Academy of Sciences, Shenyang 110169, China
- University of Chinese Academy of Sciences, Beijing 100049, China
| | - Wenfeng Liang
- School of Mechanical Engineering, Shenyang Jianzhu University, Shenyang 110168, China
| | - Lina Hao
- School of Mechanical Engineering and Automation, Northeastern University, Shenyang 110819, China.
| | - Ying Zhao
- Department of General Surgery, Shengjing Hospital of China Medical University, Shenyang, 110004, China.
| | - Lianqing Liu
- State Key Laboratory of Robotics, Shenyang Institute of Automation, Chinese Academy of Sciences, Shenyang 110016, China.
- Institutes for Robotics and Intelligent Manufacturing, Chinese Academy of Sciences, Shenyang 110169, China
| | - Wenxue Wang
- State Key Laboratory of Robotics, Shenyang Institute of Automation, Chinese Academy of Sciences, Shenyang 110016, China.
- Institutes for Robotics and Intelligent Manufacturing, Chinese Academy of Sciences, Shenyang 110169, China
| |
Collapse
|
8
|
Zheng X, Li Z, Li W, Zhu M, Zhang L, Zhu Z, Yang H. Biomechanical properties of erythrocytes circulating in artificial hearts measured by dielectrophoretic method. J Biomech 2021; 129:110822. [PMID: 34736085 DOI: 10.1016/j.jbiomech.2021.110822] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2021] [Revised: 09/28/2021] [Accepted: 10/16/2021] [Indexed: 11/16/2022]
Abstract
Blood damage is recognized as one of the major problems caused by non-physiological shear force induced by artificial hearts. At present, the generally accepted manifestation of mechanical blood damage is the amount of free hemoglobin released into the blood. However, there is little research on the changes of blood cell state after circulating in artificial hearts at the single-cell level. It is well known that the mechanical properties of cells are of enormous relevance in the regulation of cellular physiological and pathological processes. In this regard, it is highly needed to study the mechanical properties of blood cells affected by non-physiological shear force. In this paper, a dielectrophoresis-based method of measuring the mechanical properties of erythrocytes circulating in artificial hearts was proposed, which was quantified with some crucial parameters such as strain, elongation index (EI), and Young's modulus. Experimental results indicated that with the increase of the working time of artificial hearts, the deformability of erythrocytes decreased, the stiffness substantially increased, and the mechanical stability decreased, particularly at long exposure times. The proposed method provides a deep insight into the mechanism of subhemolytic damage at the single-cell level and has a great potential to serve as a new tool for in vitro evaluation of potential blood damage in artificial hearts.
Collapse
Affiliation(s)
- Xinyu Zheng
- Medical College of Soochow University, China
| | - Zhiwei Li
- Robotics and Microsystems Center, School of Mechanical and Electric Engineering, Soochow University, China
| | - Wanting Li
- Robotics and Microsystems Center, School of Mechanical and Electric Engineering, Soochow University, China
| | - Mingjie Zhu
- Robotics and Microsystems Center, School of Mechanical and Electric Engineering, Soochow University, China
| | - Liudi Zhang
- Artificial Organ Technology Lab, School of Mechanical and Electric Engineering, Soochow University, China
| | - Zhenhong Zhu
- Children's Hospital of Soochow University, China.
| | - Hao Yang
- Robotics and Microsystems Center, School of Mechanical and Electric Engineering, Soochow University, China.
| |
Collapse
|
9
|
3D numerical simulation of acoustophoretic motion induced by boundary-driven acoustic streaming in standing surface acoustic wave microfluidics. Sci Rep 2021; 11:13326. [PMID: 34172758 PMCID: PMC8233446 DOI: 10.1038/s41598-021-90825-z] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2020] [Accepted: 05/18/2021] [Indexed: 02/07/2023] Open
Abstract
Standing surface acoustic waves (SSAWs) have been widely utilized in microfluidic devices to manipulate various cells and micro/nano-objects. Despite widespread application, a time-/cost-efficient versatile 3D model that predicts particle behavior in such platforms is still lacking. Herein, a fully-coupled 3D numerical simulation of boundary-driven acoustic streaming in the acoustofluidic devices utilizing SSAWs has been conducted based on the limiting velocity finite element method. Through this efficient computational method, the underlying physical interplay from the electromechanical fields of the piezoelectric substrate to different acoustofluidic effects (acoustic radiation force and streaming-induced drag force), fluid–solid interactions, the 3D influence of novel on-chip configuration like tilted-angle SSAW (taSSAW) based devices, required boundary conditions, meshing technique, and demanding computational cost, are discussed. As an experimental validation, a taSSAW platform fabricated on YX 128 \documentclass[12pt]{minimal}
\usepackage{amsmath}
\usepackage{wasysym}
\usepackage{amsfonts}
\usepackage{amssymb}
\usepackage{amsbsy}
\usepackage{mathrsfs}
\usepackage{upgreek}
\setlength{\oddsidemargin}{-69pt}
\begin{document}$$^\circ $$\end{document}∘ LiNbO3 substrate for separating polystyrene beads is simulated, which demonstrates acceptable agreement with reported experimental observations. Subsequently, as an application of the presented 3D model, a novel sheathless taSSAW cell/particle separator is conceptualized and designed. The presented 3D fully-coupled model could be considered a powerful tool in further designing and optimizing SSAW microfluidics due to the more time-/cost-efficient performance than precedented 3D models, the capability to model complex on-chip configurations, and overcome shortcomings and limitations of 2D simulations.
Collapse
|
10
|
Rezaei B, Moghimi Zand M, Javidi R. Numerical simulation of critical particle size in asymmetrical deterministic lateral displacement. J Chromatogr A 2021; 1649:462216. [PMID: 34034107 DOI: 10.1016/j.chroma.2021.462216] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2020] [Revised: 04/19/2021] [Accepted: 04/25/2021] [Indexed: 02/06/2023]
Abstract
Microfluidics devices are widely used for particle separation. Deterministic Lateral Displacement (DLD) is a passive method for particle separation. DLD devices mainly separate particles based on their sizes. There are two main modes of movement in DLD arrays; the small particles move in a zigzag path, and the larger particles separate in the displacement mode. It is therefore important to estimate the critical particle size for the transition of modes before the fabrication of DLD devices. Asymmetry in the design of the arrays can affect the fluid behavior and the critical particle size. In this study, we investigate the effects of the asymmetry caused by changing the downstream gap size to the lateral gap size ratio on the fluid behavior and particle trajectories in DLD devices. We used two dimensional (2D) Finite Element Method (FEM) to study the variations in the flow lane's widths and combined the fluid analysis with structural mechanics to model the contact between the particles and the posts in DLD arrays. We simulated the spherical particles' trajectories with diameters ranging from 1.4 to 19.2 μm in circular post DLD arrays with a lateral gap size of 20μm. In contrast to the previous works, in these simulations, the effect of particle movement on the fluid flow profiles was considered. We evaluated the particle movement mode in seven different values of the downstream gap size to the lateral gap size ratio (ranging from 0.5 to 2) and eight different row shift fraction (ranging from 0.025 to 0.3). Our simulations showed that increasing the value of the downstream gap while the lateral gap is fixed increases the veering flow rate and width. By finding the particle with the largest diameter in the zigzag mode and the particle with the smallest diameter in the displacement mode, we estimated the critical particle diameter for each value of shift fraction in different values of the downstream gap to the lateral gap size ratio. Using these data, a curve was fitted for predicting the critical particle diameter in each ratio. Finally, a more general form of the formula for the critical particle diameter was proposed, which considers an extra parameter compared to the previous ones. The results of this study can lead to a better understanding of DLD devices' functions and, thus, save time and costs for better designs and experiments.
Collapse
Affiliation(s)
- Behnam Rezaei
- Small Medical Devices, BioMEMS & LoC Lab, School of Mechanical Engineering, College of Engineering, University of Tehran, Tehran 11155-463, Iran
| | - Mahdi Moghimi Zand
- Small Medical Devices, BioMEMS & LoC Lab, School of Mechanical Engineering, College of Engineering, University of Tehran, Tehran 11155-463, Iran.
| | - Reza Javidi
- Small Medical Devices, BioMEMS & LoC Lab, School of Mechanical Engineering, College of Engineering, University of Tehran, Tehran 11155-463, Iran
| |
Collapse
|
11
|
Latest Updates on the Advancement of Polymer-Based Biomicroelectromechanical Systems for Animal Cell Studies. ADVANCES IN POLYMER TECHNOLOGY 2021. [DOI: 10.1155/2021/8816564] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
Biological sciences have reached the fundamental unit of life: the cell. Ever-growing field of Biological Microelectromechanical Systems (BioMEMSs) is providing new frontiers in both fundamental cell research and various practical applications in cell-related studies. Among various functions of BioMEMS devices, some of the most fundamental processes that can be carried out in such platforms include cell sorting, cell separation, cell isolation or trapping, cell pairing, cell-cell communication, cell differentiation, cell identification, and cell culture. In this article, we review each mentioned application in great details highlighting the latest advancements in fabrication strategy, mechanism of operation, and application of these tools. Moreover, the review article covers the shortcomings of each specific application which can open windows of opportunity for improvement of these devices.
Collapse
|