1
|
Huang HH, Hargrove LJ, Ortiz-Catalan M, Sensinger JW. Integrating Upper-Limb Prostheses with the Human Body: Technology Advances, Readiness, and Roles in Human-Prosthesis Interaction. Annu Rev Biomed Eng 2024; 26:503-528. [PMID: 38594922 DOI: 10.1146/annurev-bioeng-110222-095816] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/11/2024]
Abstract
Significant advances in bionic prosthetics have occurred in the past two decades. The field's rapid expansion has yielded many exciting technologies that can enhance the physical, functional, and cognitive integration of a prosthetic limb with a human. We review advances in the engineering of prosthetic devices and their interfaces with the human nervous system, as well as various surgical techniques for altering human neuromusculoskeletal systems for seamless human-prosthesis integration. We discuss significant advancements in research and clinical translation, focusing on upper limbprosthetics since they heavily rely on user intent for daily operation, although many discussed technologies have been extended to lower limb prostheses as well. In addition, our review emphasizes the roles of advanced prosthetics technologies in complex interactions with humans and the technology readiness levels (TRLs) of individual research advances. Finally, we discuss current gaps and controversies in the field and point out future research directions, guided by TRLs.
Collapse
Affiliation(s)
- He Helen Huang
- Joint Department of Biomedical Engineering, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, USA
- Joint Department of Biomedical Engineering, North Carolina State University, Raleigh, North Carolina, USA;
| | - Levi J Hargrove
- Department of Physical Medicine and Rehabilitation, Northwestern University, Chicago, Illinois, USA
- Center for Bionic Medicine, Shirley Ryan AbilityLab, Chicago, Illinois, USA
| | - Max Ortiz-Catalan
- Medical Bionics Department, University of Melbourne, Melbourne, Australia
- Bionics Institute, Melbourne, Australia
| | - Jonathon W Sensinger
- Institute of Biomedical Engineering, University of New Brunswick, Fredericton, New Brunswick, Canada;
| |
Collapse
|
2
|
Fredén Jansson KJ, Håkansson B, Persson AC, Verrecchia L, Reinfeldt S. Electroacoustic evaluation of the bone conduction transducer B250 for vestibular and hearing diagnostics in comparison with Radioear B71 and B81. Int J Audiol 2024:1-7. [PMID: 38742487 DOI: 10.1080/14992027.2024.2352054] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2023] [Accepted: 04/29/2024] [Indexed: 05/16/2024]
Abstract
OBJECTIVE The objective is to evaluate the electroacoustic performance of the B250 transducer and to compare it with the two most widely used audiometric transducers B71 and B81. DESIGN The electroacoustic performance was evaluated in terms of sensitivity level, distortion, maximum hearing level and electrical impedance. STUDY SAMPLE Six B250 prototype transducers were evaluated and compared with published data of B71 and B81 together with complementary measurements of maximum hearing level at 125 Hz and phase of electrical impedance. Differences in reference equivalent threshold vibratory force levels were estimated by comparing hearing threshold measurements of 60 healthy ears using B81 and B250. RESULTS B250 has approximately 27 dB higher sensitivity levels than both B71 and B81 at 250 Hz and can generate higher maximum hearing level at low frequencies: 11.8 to 35.8 dB (125-1000 Hz) higher than B71, and 1.4 to 18.6 dB (125-750 Hz) higher than B81. The maximum average difference in reference threshold force levels was 13.5 ± 8.7 dB higher for B250 at 250 Hz compared to B81. CONCLUSIONS B250 can produce higher output force with less distortion than B71 and B81, especially at 125 and 250 Hz, which could possibly improve low frequency investigations of the audio-vestibular system.
Collapse
Affiliation(s)
| | - Bo Håkansson
- Department of Electrical Engineering, Chalmers University of Technology, Göteborg, Sweden
| | - Ann-Charlotte Persson
- Department of Otolaryngology, Head and Neck Surgery, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
- Region Västra Götaland, Habilitation & Health, Hearing Organization, Gothenburg, Sweden
| | - Luca Verrecchia
- ENT Unit, Department of Clinical Science, Intervention and Technology, Karolinska Institutet, Stockholm, Sweden
| | - Sabine Reinfeldt
- Department of Electrical Engineering, Chalmers University of Technology, Göteborg, Sweden
| |
Collapse
|
3
|
Mayer RM, Mohammadi A, Tan Y, Alici G, Choong P, Oetomo D. Temporal and spatial characteristics of bone conduction as non-invasive haptic sensory feedback for upper-limb prosthesis. Front Neurosci 2023; 17:1113009. [PMID: 37056306 PMCID: PMC10086128 DOI: 10.3389/fnins.2023.1113009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2022] [Accepted: 02/24/2023] [Indexed: 03/30/2023] Open
Abstract
Bone conduction is a promising haptic feedback modality for upper-limb prosthesis users, however, its potential and characteristics as a non-invasive feedback modality have not been thoroughly investigated. This study aimed to establish the temporal and spatial characteristics of non-invasive bone conduction as a sensory feedback interface for upper-limb prostheses. Psychometric human-subject experiments were conducted on three bony landmarks of the elbow, with a vibrotactile transducer affixed to each to provide the stimulus. The study characterized the temporal domain by testing perception threshold and resolution in amplitude and frequency. The spatial domain was evaluated by assessing the ability of subjects to detect the number of simultaneous active stimulation sites. The experiment was conducted with ten able-bodied subjects and compared to two subjects with trans-radial amputation. The psychometric evaluation of the proposed non-invasive bone conduction feedback showed results comparable to invasive methods. The experimental results demonstrated similar amplitude and frequency resolution of the interface for all three stimulation sites for both able-bodied subjects and subjects with trans-radial amputation, highlighting its potential as a non-invasive feedback modality for upper-limb prostheses.
Collapse
Affiliation(s)
- Raphael M. Mayer
- Department of Mechanical Engineering, The University of Melbourne, Parkville, VIC, Australia
- *Correspondence: Raphael M. Mayer
| | - Alireza Mohammadi
- Department of Mechanical Engineering, The University of Melbourne, Parkville, VIC, Australia
| | - Ying Tan
- Department of Mechanical Engineering, The University of Melbourne, Parkville, VIC, Australia
| | - Gursel Alici
- School of Mechanical, Materials, Mechatronic and Biomedical Engineering, University of Wollongong, Wollongong, NSW, Australia
- ARC Centre of Excellence for Electromaterials Science, Wollongong, NSW, Australia
| | - Peter Choong
- ARC Centre of Excellence for Electromaterials Science, Wollongong, NSW, Australia
- Department of Surgery, St Vincent's Hospital, The University of Melbourne, Parkville, VIC, Australia
| | - Denny Oetomo
- Department of Mechanical Engineering, The University of Melbourne, Parkville, VIC, Australia
- ARC Centre of Excellence for Electromaterials Science, Wollongong, NSW, Australia
| |
Collapse
|
4
|
Osseoperception in transcutaneous osseointegrated prosthetic systems (TOPS) after transfemoral amputation: a prospective study. Arch Orthop Trauma Surg 2023; 143:603-610. [PMID: 34345935 DOI: 10.1007/s00402-021-04099-1] [Citation(s) in RCA: 13] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/17/2021] [Accepted: 07/26/2021] [Indexed: 10/20/2022]
Abstract
BACKGROUND Endo-exo prosthetics (EEP), which belongs to the transcutaneous osseointegrated prosthetic systems (TOPS), provides an alternative bone-anchored rehabilitation method for transfemoral amputees. It led to the question of whether transmitted forces from prosthetic feet are perceptible by osseoperception resulting in proprioceptive feedback of ground conditions. OBJECTIVES The following hypotheses emerged for our trial with the null hypothesis: EEP fitting after transfemoral amputation does not influence osseoperception. Alternative hypothesis 1: EEP patients achieve better osseoperception results than transfemoral amputees fitted with socket prosthesis. Alternative hypothesis 2: EEP carriers achieve comparable results with regards to their osseoperception as non-amputees. METHODS N = 25 patients with EEP (mean age = 50,6 ± 9,4, male/female = 15/10) N = 25 patients with socket prostheses (mean age = 52,6 ± 13,1, male/female = 19/6) and N = 25 healthy volunteers were included in the experimental case-control study. In three blinded test modules (V1, V2, V3), the participants had to identify different degrees of shore hardness (c) of different materials (rubber balls (shore = 5-25c), foam cushions (shore = 5-30c), foam mats (shore = 5-30c) with their prosthetic foot (or a personally defined foot in healthy volunteers) without footwear and had to rank them into the correct order according to their tactile sensation and the degree of hardness. A maximum of 10 points could be scored per run. RESULTS This experimental observational study included N = 75 participants. The mean age for the entire cohort was 42.8 ± 16.6 years and the BMI was 26.0 ± 4.8. Our results show a significant level of differences in tactile osseoperception between all groups (p < 0.001). A correlation between the mean values of V1-3 and the PMQ2.0 as well as the mean values of K-Level and the prosthesis wearing time per day showed for PMQ (r = 0.387, p = 0.006) and K-level (r = 0.448, p = 0.001) which is a moderate effect according to Cohen. CONCLUSION Our study results suggest that the EEP treatment can lead to an improvement in tactile sensory perception via the bone-anchored implant, which can lead to an increase in quality of life and improved gait safety.
Collapse
|
5
|
González-Gil D, Dib-Zaitun I, Flores-Fraile J, López-Marcos J. Active Tactile Sensibility in Implant Prosthesis vs. Complete Dentures: A Psychophysical Study. J Clin Med 2022; 11:jcm11226819. [PMID: 36431296 PMCID: PMC9697244 DOI: 10.3390/jcm11226819] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2022] [Revised: 11/10/2022] [Accepted: 11/16/2022] [Indexed: 11/19/2022] Open
Abstract
BACKGROUND AND OBJECTIVES Proprioceptive information from natural dentition and adjacent oral tissues enables correct masticatory function, avoiding damage to the teeth. Periodontium is the main source of this relevant information, and when a tooth is lost, all this proprioceptive sensibility relies on receptors from muscles, the mucous membrane or the temporomandibular joint, and this sensibility gets worse. Active tactile sensibility measures this proprioceptive capability in microns by psychophysical studies consisting of introducing thin metal foils between patients' dental arches during chewing to see if they are able to notice them or not. Osseoperception is a complex phenomenon that seems to improve this sensibility in patients wearing dental implants. The objective of this investigation is to measure this sensibility in different prosthetic situations by performing a psychophysical investigation. MATERIAL AND METHODS We divided 67 patients in three groups depending on their prosthetic situation and performed a psychophysical study by introducing aluminium foils of different thicknesses in order to establish an active tactile sensibility threshold in every group. We also measured variables such as prosthetic wearing time, age or gender to see how they may influence threshold values. We used Student's t-test and Mann-Whitney U tests to analyse these results. RESULTS Active tactile sensibility threshold values in implants are lower than those from complete dentures but higher than values in natural dentition. However, values in implants are closer to natural dentition than complete denture values. Age, gender or prosthetic wearing time have no influence in active tactile sensibility thresholds. CONCLUSION Active tactile sensibility threshold values depend on prosthetic rehabilitations and the mechanoreceptors involved in every situation. Implant prosthesis presents an increased active tactile sensibility thanks to osseoperception phenomenon.
Collapse
|
6
|
Zbinden J, Lendaro E, Ortiz-Catalan M. A multi-dimensional framework for prosthetic embodiment: a perspective for translational research. J Neuroeng Rehabil 2022; 19:122. [PMID: 36369004 PMCID: PMC9652836 DOI: 10.1186/s12984-022-01102-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2022] [Accepted: 10/25/2022] [Indexed: 11/13/2022] Open
Abstract
The concept of embodiment has gained widespread popularity within prosthetics research. Embodiment has been claimed to be an indicator of the efficacy of sensory feedback and control strategies. Moreover, it has even been claimed to be necessary for prosthesis acceptance, albeit unfoundedly. Despite the popularity of the term, an actual consensus on how prosthetic embodiment should be used in an experimental framework has yet to be reached. The lack of consensus is in part due to terminological ambiguity and the lack of an exact definition of prosthetic embodiment itself. In a review published parallel to this article, we summarized the definitions of embodiment used in prosthetics literature and concluded that treating prosthetic embodiment as a combination of ownership and agency allows for embodiment to be quantified, and thus useful in translational research. Here, we review the potential mechanisms that give rise to ownership and agency considering temporal, spatial, and anatomical constraints. We then use this to propose a multi-dimensional framework where prosthetic embodiment arises within a spectrum dependent on the integration of volition and multi-sensory information as demanded by the degree of interaction with the environment. This framework allows for the different experimental paradigms on sensory feedback and prosthetic control to be placed in a common perspective. By considering that embodiment lays along a spectrum tied to the interactions with the environment, one can conclude that the embodiment of prosthetic devices should be assessed while operating in environments as close to daily life as possible for it to become relevant.
Collapse
|
7
|
Medrano RL, Thomas GC, Rouse EJ. Can humans perceive the metabolic benefit provided by augmentative exoskeletons? J Neuroeng Rehabil 2022; 19:26. [PMID: 35219335 PMCID: PMC8881941 DOI: 10.1186/s12984-022-01002-w] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2021] [Accepted: 02/15/2022] [Indexed: 11/30/2022] Open
Abstract
BACKGROUND The purpose of augmentative exoskeletons is to help people exceed the limitations of their human bodies, but this cannot be realized unless people choose to use these exciting technologies. Although human walking efficiency has been highly optimized over generations, exoskeletons have been able to consistently improve this efficiency by 10-15%. However, despite these measurable improvements, exoskeletons today remain confined to the laboratory. To achieve widespread adoption, exoskeletons must not only exceed the efficiency of human walking, but also provide a perceivable benefit to their wearers. METHODS In this study, we quantify the perceptual threshold of the metabolic efficiency benefit provided during exoskeleton-assisted locomotion. Ten participants wore bilateral ankle exoskeletons during continuous walking. The assistance provided by the exoskeletons was varied in 2 min intervals while participants provided feedback on their metabolic rate. These data were aggregated and used to estimate the perceptual threshold. RESULTS Participants were able to detect a change in their metabolic rate of 22.7% (SD: 17.0%) with 75% accuracy. This indicates that in the short term and on average, wearers cannot yet reliably perceive the metabolic benefits of today's augmentative exoskeletons. CONCLUSIONS If wearers cannot perceive the benefits provided by these technologies, it will negatively affect their impact, including long-term adoption and product viability. Future exoskeleton researchers and designers can use these methods and results to inform the development of exoskeletons that reach their potential.
Collapse
Affiliation(s)
- Roberto Leo Medrano
- Department of Mechanical Engineering, University of Michigan, Ann Arbor, 48109 USA
- Robotics Institute, University of Michigan, 48109 Ann Arbor, USA
| | - Gray Cortright Thomas
- Department of Mechanical Engineering, University of Michigan, Ann Arbor, 48109 USA
- Department of Electrical Engineering and Computer Science, University of Michigan, Ann Arbor, 48109 USA
- Robotics Institute, University of Michigan, 48109 Ann Arbor, USA
| | - Elliott J. Rouse
- Department of Mechanical Engineering, University of Michigan, Ann Arbor, 48109 USA
- Robotics Institute, University of Michigan, 48109 Ann Arbor, USA
| |
Collapse
|
8
|
Testing silicone digit extensions as a way to suppress natural sensation to evaluate supplementary tactile feedback. PLoS One 2021; 16:e0256753. [PMID: 34469470 PMCID: PMC8410127 DOI: 10.1371/journal.pone.0256753] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2020] [Accepted: 08/13/2021] [Indexed: 11/19/2022] Open
Abstract
Dexterous use of the hands depends critically on sensory feedback, so it is generally agreed that functional supplementary feedback would greatly improve the use of hand prostheses. Much research still focuses on improving non-invasive feedback that could potentially become available to all prosthesis users. However, few studies on supplementary tactile feedback for hand prostheses demonstrated a functional benefit. We suggest that confounding factors impede accurate assessment of feedback, e.g., testing non-amputee participants that inevitably focus intently on learning EMG control, the EMG’s susceptibility to noise and delays, and the limited dexterity of hand prostheses. In an attempt to assess the effect of feedback free from these constraints, we used silicone digit extensions to suppress natural tactile feedback from the fingertips and thus used the tactile feedback-deprived human hand as an approximation of an ideal feed-forward tool. Our non-amputee participants wore the extensions and performed a simple pick-and-lift task with known weight, followed by a more difficult pick-and-lift task with changing weight. They then repeated these tasks with one of three kinds of audio feedback. The tests were repeated over three days. We also conducted a similar experiment on a person with severe sensory neuropathy to test the feedback without the extensions. Furthermore, we used a questionnaire based on the NASA Task Load Index to gauge the subjective experience. Unexpectedly, we did not find any meaningful differences between the feedback groups, neither in the objective nor the subjective measurements. It is possible that the digit extensions did not fully suppress sensation, but since the participant with impaired sensation also did not improve with the supplementary feedback, we conclude that the feedback failed to provide relevant grasping information in our experiments. The study highlights the complex interaction between task, feedback variable, feedback delivery, and control, which seemingly rendered even rich, high-bandwidth acoustic feedback redundant, despite substantial sensory impairment.
Collapse
|
9
|
Wang D, Tao J, Jin A, Yu H. Tactile sensation of natural teeth and dental implants in the somatosensory cortex. J Prosthodont Res 2021; 66:272-278. [PMID: 34349082 DOI: 10.2186/jpr.jpr_d_20_00281] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
PURPOSE This study aimed to investigate the cortical response characteristics evoked by natural teeth and implants. METHODS Five cats were subjected to intrinsic signal optical imaging to measure the cortical responses evoked by natural teeth and implants. The difference in tactile sensation between the implant and natural tooth was compared in detail at the cortical response level. RESULTS Some similarities were observed between the implants and natural teeth. The stimulating-response curves of the implants and natural teeth were generally S-curves, and both implants and natural teeth preferred labial-lingual direction stimulation. The implants and natural teeth differed in terms of their tactile sensitivity: implants were weaker than natural teeth in terms of both static and dynamic sensitivity. However, after saturation, there was no significant difference in tactile strength between implants and natural teeth. CONCLUSIONS Both natural teeth and implants are able to distinguish the tactile strength and stimulation direction. Although implants are less sensitive than the natural tooth, the maximal tactile function and directional preference of implants are similar to those of natural teeth.
Collapse
Affiliation(s)
- Duo Wang
- Vision Research Laboratory, School of Life Sciences, The State Key Laboratory of Medical Neurobiology, Collaborative Innovation Center for Brain Science,Fudan University, Shanghai
| | - Jianxiang Tao
- Department of Prosthodontics, School &Hospital of Stomatology, Tongji University, Shanghai Engineering Research Center of Tooth Restoration and Regeneration, Shanghai
| | - Anqi Jin
- Vision Research Laboratory, School of Life Sciences, The State Key Laboratory of Medical Neurobiology, Collaborative Innovation Center for Brain Science,Fudan University, Shanghai
| | - Hongbo Yu
- Vision Research Laboratory, School of Life Sciences, The State Key Laboratory of Medical Neurobiology, Collaborative Innovation Center for Brain Science,Fudan University, Shanghai
| |
Collapse
|
10
|
Karczewski AM, Dingle AM, Poore SO. The Need to Work Arm in Arm: Calling for Collaboration in Delivering Neuroprosthetic Limb Replacements. Front Neurorobot 2021; 15:711028. [PMID: 34366820 PMCID: PMC8334559 DOI: 10.3389/fnbot.2021.711028] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2021] [Accepted: 06/22/2021] [Indexed: 11/21/2022] Open
Abstract
Over the last few decades there has been a push to enhance the use of advanced prosthetics within the fields of biomedical engineering, neuroscience, and surgery. Through the development of peripheral neural interfaces and invasive electrodes, an individual's own nervous system can be used to control a prosthesis. With novel improvements in neural recording and signal decoding, this intimate communication has paved the way for bidirectional and intuitive control of prostheses. While various collaborations between engineers and surgeons have led to considerable success with motor control and pain management, it has been significantly more challenging to restore sensation. Many of the existing peripheral neural interfaces have demonstrated success in one of these modalities; however, none are currently able to fully restore limb function. Though this is in part due to the complexity of the human somatosensory system and stability of bioelectronics, the fragmentary and as-yet uncoordinated nature of the neuroprosthetic industry further complicates this advancement. In this review, we provide a comprehensive overview of the current field of neuroprosthetics and explore potential strategies to address its unique challenges. These include exploration of electrodes, surgical techniques, control methods, and prosthetic technology. Additionally, we propose a new approach to optimizing prosthetic limb function and facilitating clinical application by capitalizing on available resources. It is incumbent upon academia and industry to encourage collaboration and utilization of different peripheral neural interfaces in combination with each other to create versatile limbs that not only improve function but quality of life. Despite the rapidly evolving technology, if the field continues to work in divided "silos," we will delay achieving the critical, valuable outcome: creating a prosthetic limb that is right for the patient and positively affects their life.
Collapse
Affiliation(s)
| | - Aaron M. Dingle
- Division of Plastic Surgery, Department of Surgery, University of Wisconsin–Madison, Madison, WI, United States
| | | |
Collapse
|
11
|
Zbinden J, Ortiz-Catalan M. The rubber hand illusion is a fallible method to study ownership of prosthetic limbs. Sci Rep 2021; 11:4423. [PMID: 33627714 PMCID: PMC7904923 DOI: 10.1038/s41598-021-83789-7] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2020] [Accepted: 02/05/2021] [Indexed: 11/25/2022] Open
Abstract
Enabling sensory feedback in limb prostheses can reverse a damaged body image caused by amputation. The rubber hand illusion (RHI) is a popular paradigm to study ownership of artificial limbs and potentially useful to assess sensory feedback strategies. We investigated the RHI as means to induce ownership of a prosthetic hand by providing congruent visual and tactile stimuli. We elicited tactile sensations via electric stimulation of severed afferent nerve fibres in four participants with transhumeral amputation. Contrary to our expectations, they failed to experience the RHI. The sensations we elicited via nerve stimulation resemble tapping as opposed to stroking, as in the original RHI. We therefore investigated the effect of tapping versus stroking in 30 able-bodied subjects. We found that either tactile modality equally induced ownership in two-thirds of the subjects. Failure to induce the RHI in the intact hand of our participants with amputation later confirmed that they form part of the RHI-immune population. Conversely, these participants use neuromusculoskeletal prostheses with neural sensory feedback in their daily lives and reported said prostheses as part of their body. Our findings suggest that people immune to the RHI can nevertheless experience ownership over prosthetic limbs when used in daily life and accentuates a significant limitation of the RHI paradigm.
Collapse
Affiliation(s)
- Jan Zbinden
- Center for Bionics and Pain Research, Mölndal, Sweden
- Department of Electrical Engineering, Chalmers University of Technology, Gothenburg, Sweden
| | - Max Ortiz-Catalan
- Center for Bionics and Pain Research, Mölndal, Sweden.
- Department of Electrical Engineering, Chalmers University of Technology, Gothenburg, Sweden.
- Operational Area 3, Sahlgrenska University Hospital, Mölndal, Sweden.
- Department of Orthopaedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.
| |
Collapse
|
12
|
Mastinu E, Engels LF, Clemente F, Dione M, Sassu P, Aszmann O, Brånemark R, Håkansson B, Controzzi M, Wessberg J, Cipriani C, Ortiz-Catalan M. Neural feedback strategies to improve grasping coordination in neuromusculoskeletal prostheses. Sci Rep 2020; 10:11793. [PMID: 32678121 PMCID: PMC7367346 DOI: 10.1038/s41598-020-67985-5] [Citation(s) in RCA: 33] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2020] [Accepted: 06/11/2020] [Indexed: 11/09/2022] Open
Abstract
Conventional prosthetic arms suffer from poor controllability and lack of sensory feedback. Owing to the absence of tactile sensory information, prosthetic users must rely on incidental visual and auditory cues. In this study, we investigated the effect of providing tactile perception on motor coordination during routine grasping and grasping under uncertainty. Three transhumeral amputees were implanted with an osseointegrated percutaneous implant system for direct skeletal attachment and bidirectional communication with implanted neuromuscular electrodes. This neuromusculoskeletal prosthesis is a novel concept of artificial limb replacement that allows to extract control signals from electrodes implanted on viable muscle tissue, and to stimulate severed afferent nerve fibers to provide somatosensory feedback. Subjects received tactile feedback using three biologically inspired stimulation paradigms while performing a pick and lift test. The grasped object was instrumented to record grasping and lifting forces and its weight was either constant or unexpectedly changed in between trials. The results were also compared to the no-feedback control condition. Our findings confirm, in line with the neuroscientific literature, that somatosensory feedback is necessary for motor coordination during grasping. Our results also indicate that feedback is more relevant under uncertainty, and its effectiveness can be influenced by the selected neuromodulation paradigm and arguably also the prior experience of the prosthesis user.
Collapse
Affiliation(s)
- Enzo Mastinu
- Center for Bionics and Pain Research, Mölndal, Sweden
- Department of Electrical Engineering, Chalmers University of Technology, Gothenburg, Sweden
| | - Leonard F Engels
- The Biorobotics Institute, Scuola Superiore Sant'Anna, Pisa, Italy
- Department of Excellence in Robotics & AI, Scuola Superiore Sant'Anna, Pisa, Italy
| | - Francesco Clemente
- The Biorobotics Institute, Scuola Superiore Sant'Anna, Pisa, Italy
- Department of Excellence in Robotics & AI, Scuola Superiore Sant'Anna, Pisa, Italy
- Prensilia SRL, Pontedera, Italy
| | - Mariama Dione
- Department of Physiology, Institute of Neuroscience and Physiology, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| | - Paolo Sassu
- Department of Hand Surgery, Sahlgrenska University Hospital, Gothenburg, Sweden
| | - Oskar Aszmann
- Clinical Laboratory for Bionic Extremity Reconstruction, Division of Plastic and Reconstructive Surgery, Medical University of Vienna, Vienna, Austria
| | - Rickard Brånemark
- Department of Orthopaedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
- Center for Extreme Bionics, Biomechatronics Group, MIT Media Lab, Massachusetts Institute of Technology, Cambridge, MA, USA
| | - Bo Håkansson
- Department of Electrical Engineering, Chalmers University of Technology, Gothenburg, Sweden
| | - Marco Controzzi
- The Biorobotics Institute, Scuola Superiore Sant'Anna, Pisa, Italy
- Department of Excellence in Robotics & AI, Scuola Superiore Sant'Anna, Pisa, Italy
| | - Johan Wessberg
- Department of Physiology, Institute of Neuroscience and Physiology, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| | - Christian Cipriani
- The Biorobotics Institute, Scuola Superiore Sant'Anna, Pisa, Italy
- Department of Excellence in Robotics & AI, Scuola Superiore Sant'Anna, Pisa, Italy
| | - Max Ortiz-Catalan
- Center for Bionics and Pain Research, Mölndal, Sweden.
- Department of Electrical Engineering, Chalmers University of Technology, Gothenburg, Sweden.
- Department of Orthopaedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.
- Operational Area 3, Sahlgrenska University Hospital, Mölndal, Sweden.
| |
Collapse
|
13
|
Mayer RM, Garcia-Rosas R, Mohammadi A, Tan Y, Alici G, Choong P, Oetomo D. Tactile Feedback in Closed-Loop Control of Myoelectric Hand Grasping: Conveying Information of Multiple Sensors Simultaneously via a Single Feedback Channel. Front Neurosci 2020; 14:348. [PMID: 32395102 PMCID: PMC7197324 DOI: 10.3389/fnins.2020.00348] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2019] [Accepted: 03/23/2020] [Indexed: 12/03/2022] Open
Abstract
The appropriate sensory information feedback is important for the success of an object grasping and manipulation task. In many scenarios, the need arises for multiple feedback information to be conveyed to a prosthetic hand user simultaneously. The multiple sets of information may either (1) directly contribute to the performance of the grasping or object manipulation task, such as the feedback of the grasping force, or (2) simply form additional independent set(s) of information. In this paper, the efficacy of simultaneously conveying two independent sets of sensor information (the grasp force and a secondary set of information) through a single channel of feedback stimulation (vibrotactile via bone conduction) to the human user in a prosthetic application is investigated. The performance of the grasping task is not dependent to the second set of information in this study. Subject performance in two tasks: regulating the grasp force and identifying the secondary information, were evaluated when provided with either one corresponding information or both sets of feedback information. Visual feedback is involved in the training stage. The proposed approach is validated on human-subject experiments using a vibrotactile transducer worn on the elbow bony landmark (to realize a non-invasive bone conduction interface) carried out in a virtual reality environment to perform a closed-loop object grasping task. The experimental results show that the performance of the human subjects on either task, whilst perceiving two sets of sensory information, is not inferior to that when receiving only one set of corresponding sensory information, demonstrating the potential of conveying a second set of information through a bone conduction interface in an upper limb prosthetic task.
Collapse
Affiliation(s)
- Raphael M Mayer
- Human Robotics Laboratory, Department of Mechanical Engineering, The University of Melbourne, Parkville, VIC, Australia
| | - Ricardo Garcia-Rosas
- Human Robotics Laboratory, Department of Mechanical Engineering, The University of Melbourne, Parkville, VIC, Australia
| | - Alireza Mohammadi
- Human Robotics Laboratory, Department of Mechanical Engineering, The University of Melbourne, Parkville, VIC, Australia
| | - Ying Tan
- Human Robotics Laboratory, Department of Mechanical Engineering, The University of Melbourne, Parkville, VIC, Australia
| | - Gursel Alici
- School of Mechanical, Materials, Mechatronic and Biomedical Engineering, University of Wollongong, Wollongong, NSW, Australia.,ARC Centre of Excellence for Electromaterials Science, Wollongong, NSW, Australia
| | - Peter Choong
- ARC Centre of Excellence for Electromaterials Science, Wollongong, NSW, Australia.,Department of Surgery, St. Vincent's Hospital, The University of Melbourne, Parkville, VIC, Australia
| | - Denny Oetomo
- Human Robotics Laboratory, Department of Mechanical Engineering, The University of Melbourne, Parkville, VIC, Australia.,ARC Centre of Excellence for Electromaterials Science, Wollongong, NSW, Australia
| |
Collapse
|
14
|
Mayer RM, Mohammadi A, Alici G, Choong P, Oetomo D. Bone Conduction as Sensory Feedback Interface: A Preliminary Study. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2019; 2019:5322-5325. [PMID: 31947058 DOI: 10.1109/embc.2019.8856424] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
Non-invasive sensory feedback is a desirable goal for upper limb prostheses as well as in human robot interaction and other human machine interfaces. Yet many approaches have been studied, none has been broadly deployed in upper limb prostheses. Bone conduction has the potential to excite an effect known as osseoperception and therefore provides a novel sensory interface. This paper presents the preliminary results of our study into the temporal parameters of a sensory feedback interface utilizing vibrotactile stimulus onto the ulnar olecranon representing a non-invasive sensory feedback interface. Three different tests are performed to establish the characterizing parameters of the interface; perception threshold, sensation discrimination and reaction time. Our results are similar to the results obtained for invasive bone conduction. The perception threshold for lower frequencies is small and therefore allows using small transducers with low power consumption. The sensation discrimination shows comparable results as reported in existing literature as well as the reaction time for the amputee is within the same range.
Collapse
|
15
|
Mastinu E, Clemente F, Sassu P, Aszmann O, Brånemark R, Håkansson B, Controzzi M, Cipriani C, Ortiz-Catalan M. Grip control and motor coordination with implanted and surface electrodes while grasping with an osseointegrated prosthetic hand. J Neuroeng Rehabil 2019; 16:49. [PMID: 30975158 PMCID: PMC6460734 DOI: 10.1186/s12984-019-0511-2] [Citation(s) in RCA: 29] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2018] [Accepted: 03/05/2019] [Indexed: 11/13/2022] Open
Abstract
Background Replacement of a lost limb by an artificial substitute is not yet ideal. Resolution and coordination of motor control approximating that of a biological limb could dramatically improve the functionality of prosthetic devices, and thus reduce the gap towards a suitable limb replacement. Methods In this study, we investigated the control resolution and coordination exhibited by subjects with transhumeral amputation who were implanted with epimysial electrodes and an osseointegrated interface that provides bidirectional communication in addition to skeletal attachment (e-OPRA Implant System). We assessed control resolution and coordination in the context of routine and delicate grasping using the Pick and Lift and the Virtual Eggs Tests. Performance when utilizing implanted electrodes was compared with the standard-of-care technology for myoelectric prostheses, namely surface electrodes. Results Results showed that implanted electrodes provide superior controllability over the prosthetic terminal device compared to conventional surface electrodes. Significant improvements were found in the control of the grip force and its reliability during object transfer. However, these improvements failed to increase motor coordination, and surprisingly decreased the temporal correlation between grip and load forces observed with surface electrodes. We found that despite being more functional and reliable, prosthetic control via implanted electrodes still depended highly on visual feedback. Conclusions Our findings indicate that incidental sensory feedback (visual, auditory, and osseoperceptive in this case) is insufficient for restoring natural grasp behavior in amputees, and support the idea that supplemental tactile sensory feedback is needed to learn and maintain the motor tasks internal model, which could ultimately restore natural grasp behavior in subjects using prosthetic hands.
Collapse
Affiliation(s)
- Enzo Mastinu
- Department of Electrical Engineering, Chalmers University of Technology, Gothenburg, Sweden.
| | - Francesco Clemente
- The Biorobotics Institute, Scuola Superiore Sant'Anna, Pisa, Italy.,Prensilia SRL, Pisa, Italy
| | - Paolo Sassu
- Department of Hand Surgery, Sahlgrenska University Hospital, Gothenburg, Sweden
| | - Oskar Aszmann
- Christian Doppler Laboratory for Restoration of Extremity Function, Department of Surgery, Medical University of Vienna, Vienna, Austria
| | - Rickard Brånemark
- Department of Orthopaedics, Gothenburg University, Gothenburg, Sweden
| | - Bo Håkansson
- Department of Electrical Engineering, Chalmers University of Technology, Gothenburg, Sweden
| | - Marco Controzzi
- The Biorobotics Institute, Scuola Superiore Sant'Anna, Pisa, Italy
| | | | - Max Ortiz-Catalan
- Department of Electrical Engineering, Chalmers University of Technology, Gothenburg, Sweden
| |
Collapse
|
16
|
Thumb Amputations Treated With Osseointegrated Percutaneous Prostheses With Up to 25 Years of Follow-up. JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS GLOBAL RESEARCH AND REVIEWS 2019; 3:e097. [PMID: 30788458 PMCID: PMC6365303 DOI: 10.5435/jaaosglobal-d-18-00097] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Introduction Implantation of an osseointegrated percutaneous prosthesis provides a reconstruction alternative for thumb amputation without sacrificing donor tissues. Methods Thirteen thumb amputees received osseointegrated prostheses (1990 to 2014). The treatments were started with custom-designed implants. Since 2005, standardized implant components and structured rehabilitation protocols were introduced. The median follow-up period was 9.5 years. Results Six patients were lost to follow-up. Seven patients (including all six after the introduction of the standardized protocol) had good osseoperception, grip strength (Jamar) was 28.3 kg on the operated side versus 40.4 kg in the unaffected hand (70%), and key grip strength was 6 versus 9.1 kg. Hand function was 94% of the normal hand. The most common complications were mechanical failures necessitating changes of components (eight times in three patients) and superficial infections (seven times in five patients). Five patients had no complications. The refined implant design and new standardized treatment protocol achieved a 100% cumulative success rate with 9.5 years of follow-up so far. Discussion Treatment of thumb amputees using bone-anchored percutaneous prostheses seems to be a safe, durable method with excellent short- and medium-long follow-up results. Severe adverse events are few except for implant loosening which occurred only in the early custom-designed group.
Collapse
|
17
|
Ferrari F, Clemente F, Cipriani C. The preload force affects the perception threshold of muscle vibration-induced movement illusions. Exp Brain Res 2018; 237:111-120. [PMID: 30341466 PMCID: PMC6514251 DOI: 10.1007/s00221-018-5402-4] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2018] [Accepted: 10/12/2018] [Indexed: 11/12/2022]
Abstract
The control and the execution of motor tasks are largely influenced by proprioceptive feedback, i.e. the information about the position and movement of the body. In 1972, it was discovered that a vibratory stimulation applied non-invasively to a muscle or a tendon induces a movement illusion consistent with the elongation of the vibrated muscle/tendon. Although this phenomenon was reported by several studies, it is still unclear how to reliably reproduce it because of the many different features of the stimulation altering the sensation (e.g. frequency, duration, location). By performing a psychophysical test, we analysed the effects of the stimulation point and the preload force on the minimum stimulation amplitude needed to elicit an illusion of movement. In particular, we stimulated two groups of healthy subjects on three target regions of the biceps brachii muscle (the distal tendon, the muscle belly and one of the proximal tendons) applying three preload force ranges (0.5–0.75N, 1–2N and 3–4N). Our results showed that the minimum stimulation amplitude eliciting a sensation is affected by the preload force. On the contrary, it did not change significantly among the three stimulated regions. Nevertheless, the reported vividness of the illusion of movement changed across the stimulated points decreasing while moving from the distal to the proximal tendons. Overall, these outcomes contribute to the scientific debate on the features that modulate the vibration-induced movement illusion proposing ways to increase the reliability of the procedure in basic and applied research studies.
Collapse
Affiliation(s)
- Francesca Ferrari
- The BioRobotics Institute, Scuola Superiore Sant'Anna, Viale Rinaldo Piaggio, 34, 56025, Pontedera, PI, Italy.
| | - Francesco Clemente
- The BioRobotics Institute, Scuola Superiore Sant'Anna, Viale Rinaldo Piaggio, 34, 56025, Pontedera, PI, Italy
| | - Christian Cipriani
- The BioRobotics Institute, Scuola Superiore Sant'Anna, Viale Rinaldo Piaggio, 34, 56025, Pontedera, PI, Italy
| |
Collapse
|
18
|
Brunton E, Blau CW, Nazarpour K. Separability of neural responses to standardised mechanical stimulation of limbs. Sci Rep 2017; 7:11138. [PMID: 28894171 PMCID: PMC5593983 DOI: 10.1038/s41598-017-11349-z] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2017] [Accepted: 08/18/2017] [Indexed: 12/21/2022] Open
Abstract
Considerable scientific and technological efforts are currently being made towards the development of neural prostheses. Understanding how the peripheral nervous system responds to electro-mechanical stimulation of the limb, will help to inform the design of prostheses that can restore function or accelerate recovery from injury to the sensory motor system. However, due to differences in experimental protocols, it is difficult, if not impossible, to make meaningful comparisons between different peripheral nerve interfaces. Therefore, we developed a low-cost electronic system to standardise the mechanical stimulation of a rat’s hindpaw. Three types of mechanical stimulations, namely, proprioception, touch and nociception were delivered to the limb and the electroneurogram signals were recorded simultaneously from the sciatic nerve with a 16-contact cuff electrode. For the first time, results indicate separability of neural responses according to stimulus type as well as intensity. Statistical analysis reveal that cuff contacts placed circumferentially, rather than longitudinally, are more likely to lead to higher classification rates. This flexible setup may be readily adapted for systematic comparison of various electrodes and mechanical stimuli in rodents. Hence, we have made its electro-mechanical design and computer programme available online
Collapse
Affiliation(s)
- Emma Brunton
- School of Engineering, Newcastle University, Newcastle-upon-Tyne, NE1 7RU, Newcastle, UK.
| | - Christoph W Blau
- Faculty of Medical Sciences, Newcastle University, Newcastle-upon-Tyne, NE1 7RU, Newcastle, UK
| | - Kianoush Nazarpour
- School of Engineering, Newcastle University, Newcastle-upon-Tyne, NE1 7RU, Newcastle, UK.,Institute of Neuroscience, Newcastle University, Newcastle-upon-Tyne, NE2 4HH, Newcastle, UK
| |
Collapse
|