1
|
Damagatla V, Boetti NG, Di Sieno L, Bargigia I, Negretti F, Pugliese D, Janner D, Spinelli L, Farina A, Pifferi A. Use of bioresorbable fibers for short-wave infrared spectroscopy using time-domain diffuse optics. BIOMEDICAL OPTICS EXPRESS 2024; 15:5041-5052. [PMID: 39296383 PMCID: PMC11407265 DOI: 10.1364/boe.531681] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/03/2024] [Revised: 07/08/2024] [Accepted: 07/08/2024] [Indexed: 09/21/2024]
Abstract
We demonstrate the usability of bioresorbable phosphate glass fibers for time-domain diffuse optical spectroscopy (TD-DOS) in the short-wave infrared (SWIR) region of 950-1600 nm, with the use of an InGaAs detector. Bioresorbable fibers for diffuse optics present an exciting prospect due to their ability to be left implanted while retrieving optical properties from deeper regions (few cm) for monitoring treatments. Extending TD-DOS to the SWIR region could be useful to better identify biomarkers such as water, lipids and collagen, given their increase in absorption in this range. We attempt to use the bioresorbable fibers to spectrally identify these biomarkers by measuring a series of biological samples known to contain them, such as porcine muscle, porcine fat and bone. We further validate our measurements by comparing the optical properties of high-scattering solid silicone phantoms retrieved with these bioresorbable fibers with those by a standard Si fiber.
Collapse
Affiliation(s)
| | - Nadia G Boetti
- Fondazione LINKS-Leading Innovation and Knowledge for Society, Torino, Italy
| | - Laura Di Sieno
- Politecnico di Milano, Dipartimento di Fisica, Milano, Italy
| | - Ilaria Bargigia
- Politecnico di Milano, Dipartimento di Fisica, Milano, Italy
- Center for Nano Science and Technology@PoliMi, Istituto Italiano di Tecnologia, Milano, Italy
| | - Fabio Negretti
- Politecnico di Milano, Dipartimento di Fisica, Milano, Italy
| | - Diego Pugliese
- Politecnico di Torino, Dipartimento di Scienza Applicata e Tecnologia and INSTM Research Unit, Torino, Italy
- Istituto Nazionale di Ricerca Metrologica (INRiM), Torino, Italy
| | - Davide Janner
- Politecnico di Torino, Dipartimento di Scienza Applicata e Tecnologia and INSTM Research Unit, Torino, Italy
| | - Lorenzo Spinelli
- Istituto di Fotonica e Nanotecnologie, Consiglio Nazionale delle Ricerche, Milano, Italy
| | - Andrea Farina
- Istituto di Fotonica e Nanotecnologie, Consiglio Nazionale delle Ricerche, Milano, Italy
| | - Antonio Pifferi
- Politecnico di Milano, Dipartimento di Fisica, Milano, Italy
- Istituto di Fotonica e Nanotecnologie, Consiglio Nazionale delle Ricerche, Milano, Italy
| |
Collapse
|
2
|
Fasciani I, Petragnano F, Bono F, Aloisi G, Mutti V, Pardini C, Carli M, Scarselli M, Vaglini F, Angelucci A, Fiorentini C, Lozzi L, Missale C, Maggio R, Rossi M. In-vitro Approaches to Investigate the Detrimental Effect of Light on Dopaminergic Neurons. Neuroscience 2024; 544:104-116. [PMID: 38244669 DOI: 10.1016/j.neuroscience.2024.01.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2023] [Revised: 01/08/2024] [Accepted: 01/11/2024] [Indexed: 01/22/2024]
Abstract
Our recent study revealed that fluorescent lamp light can penetrate deep into the brain of mice and rats leading to the development of typical histological characteristics associated with Parkinson's disease such as the loss of dopamine neurons in the substantia nigra. Monochromatic LED lights were thus used in this work to deepen our knowledge on the effects of the major wavelength peaks of fluorescent light on mouse and human dopaminergic cells. In particular, we exposed immortalized dopaminergic MN9D neuronal cells, primary cultures of mouse mesencephalic dopaminergic cells and human dopaminergic neurons differentiated from induced pluripotent stem cells (hiPSC) to different LED light wavelengths. We found that chronic exposure to LED light reduced overall undifferentiated MN9D cell number, with the most significant effects observed at wavelengths of 485 nm and 610 nm. Moreover, LED light especially at 610 nm was able to negatively impact on the survival of mouse mesencephalic dopaminergic cells and of human dopaminergic neurons derived from hiPSC. Notably, differentiated MN9D dopaminergic cells, which closely resemble mature dopamine neuronal phenotype, acutely exposed for 3 h at 610 nm, showed a clear increase in ROS production and cytotoxicity compared to controls undifferentiated MN9D cells. These increases were even more pronounced by the co-treatment with the oxidative agent H2O2. Collectively, these findings suggest that specific wavelengths, particularly those capable of penetrating deep into the brain, could potentially pose an environmental hazard in relation to Parkinson's disease.
Collapse
Affiliation(s)
- Irene Fasciani
- Department of Biotechnological and Applied Clinical Sciences, University of L'Aquila, 67100 L'Aquila, Italy
| | - Francesco Petragnano
- Department of Biotechnological and Applied Clinical Sciences, University of L'Aquila, 67100 L'Aquila, Italy
| | - Federica Bono
- Section of Pharmacology, Department of Molecular and Translational Medicine, University of Brescia, Viale Europa 11, 25123 Brescia, Italy
| | - Gabriella Aloisi
- Department of Biotechnological and Applied Clinical Sciences, University of L'Aquila, 67100 L'Aquila, Italy
| | - Veronica Mutti
- Section of Pharmacology, Department of Molecular and Translational Medicine, University of Brescia, Viale Europa 11, 25123 Brescia, Italy
| | - Carla Pardini
- Department of Translational Research and New Technologies in Medicine and Surgery, University of Pisa, Pisa, Italy
| | - Marco Carli
- Department of Translational Research and New Technologies in Medicine and Surgery, University of Pisa, Pisa, Italy
| | - Marco Scarselli
- Department of Translational Research and New Technologies in Medicine and Surgery, University of Pisa, Pisa, Italy
| | - Francesca Vaglini
- Department of Translational Research and New Technologies in Medicine and Surgery, University of Pisa, Pisa, Italy
| | - Adriano Angelucci
- Department of Biotechnological and Applied Clinical Sciences, University of L'Aquila, 67100 L'Aquila, Italy
| | - Chiara Fiorentini
- Section of Pharmacology, Department of Molecular and Translational Medicine, University of Brescia, Viale Europa 11, 25123 Brescia, Italy
| | - Luca Lozzi
- Department of Physical and Chemical Science, University of L'Aquila, via Vetoio, Coppito, 67100 L'Aquila, Italy
| | - Cristina Missale
- Section of Pharmacology, Department of Molecular and Translational Medicine, University of Brescia, Viale Europa 11, 25123 Brescia, Italy
| | - Roberto Maggio
- Department of Biotechnological and Applied Clinical Sciences, University of L'Aquila, 67100 L'Aquila, Italy
| | - Mario Rossi
- Department of Biotechnological and Applied Clinical Sciences, University of L'Aquila, 67100 L'Aquila, Italy.
| |
Collapse
|
3
|
Gautheron A, Bernstock JD, Picart T, Guyotat J, Valdés PA, Montcel B. 5-ALA induced PpIX fluorescence spectroscopy in neurosurgery: a review. Front Neurosci 2024; 18:1310282. [PMID: 38348134 PMCID: PMC10859467 DOI: 10.3389/fnins.2024.1310282] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2023] [Accepted: 01/02/2024] [Indexed: 02/15/2024] Open
Abstract
The review begins with an overview of the fundamental principles/physics underlying light, fluorescence, and other light-matter interactions in biological tissues. It then focuses on 5-aminolevulinic acid (5-ALA)-induced protoporphyrin IX (PpIX) fluorescence spectroscopy methods used in neurosurgery (e.g., intensity, time-resolved) and in so doing, describe their specific features (e.g., hardware requirements, main processing methods) as well as their strengths and limitations. Finally, we review current clinical applications and future directions of 5-ALA-induced protoporphyrin IX (PpIX) fluorescence spectroscopy in neurosurgery.
Collapse
Affiliation(s)
- A. Gautheron
- Université Jean Monnet Saint-Etienne, CNRS, Institut d Optique Graduate School, Laboratoire Hubert Curien UMR 5516, Saint-Étienne, France
- Univ Lyon, INSA-Lyon, Université Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1294, Lyon, France
| | - J. D. Bernstock
- Department of Neurosurgery, Brigham and Women’s Hospital and Harvard Medical School, Boston, MA, United States
- David H. Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA, United States
| | - T. Picart
- Department of Neurosurgical Oncology and Vascular Neurosurgery, Pierre Wertheimer Neurological and Neurosurgical Hospital, Hospices Civils de Lyon, Lyon, France
- Université Lyon 1, INSERM 1052, CNRS 5286, Lyon, France
| | - J. Guyotat
- Department of Neurosurgical Oncology and Vascular Neurosurgery, Pierre Wertheimer Neurological and Neurosurgical Hospital, Hospices Civils de Lyon, Lyon, France
| | - P. A. Valdés
- Department of Neurosurgery, University of Texas Medical Branch, Galveston, TX, United States
- Department of Neurobiology, University of Texas Medical Branch, Galveston, TX, United States
- Department of Electrical and Computer Engineering, Rice University, Houston, TX, United States
| | - B. Montcel
- Univ Lyon, INSA-Lyon, Université Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1294, Lyon, France
| |
Collapse
|
4
|
Jin Z, Lakshmanan A, Zhang R, Tran TA, Rabut C, Dutka P, Duan M, Hurt RC, Malounda D, Yao Y, Shapiro MG. Ultrasonic reporters of calcium for deep tissue imaging of cellular signals. BIORXIV : THE PREPRINT SERVER FOR BIOLOGY 2023:2023.11.09.566364. [PMID: 37986929 PMCID: PMC10659314 DOI: 10.1101/2023.11.09.566364] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/22/2023]
Abstract
Calcium imaging has enabled major biological discoveries. However, the scattering of light by tissue limits the use of standard fluorescent calcium indicators in living animals. To address this limitation, we introduce the first genetically encoded ultrasonic reporter of calcium (URoC). Based on a unique class of air-filled protein nanostructures called gas vesicles, we engineered URoC to produce elevated nonlinear ultrasound signal upon binding to calcium ions. With URoC expressed in mammalian cells, we demonstrate noninvasive ultrasound imaging of calcium signaling in vivo during drug-induced receptor activation. URoC brings the depth and resolution advantages of ultrasound to the in vivo imaging of dynamic cellular function and paves the way for acoustic biosensing of a broader variety of biological signals.
Collapse
|
5
|
Setchfield K, Gorman A, Simpson AHRW, Somekh MG, Wright AJ. Relevance and utility of the in-vivo and ex-vivo optical properties of the skin reported in the literature: a review [Invited]. BIOMEDICAL OPTICS EXPRESS 2023; 14:3555-3583. [PMID: 37497524 PMCID: PMC10368038 DOI: 10.1364/boe.493588] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 04/18/2023] [Revised: 06/07/2023] [Accepted: 06/07/2023] [Indexed: 07/28/2023]
Abstract
Imaging non-invasively into the human body is currently limited by cost (MRI and CT scan), image resolution (ultrasound), exposure to ionising radiation (CT scan and X-ray), and the requirement for exogenous contrast agents (CT scan and PET scan). Optical imaging has the potential to overcome all these issues but is currently limited by imaging depth due to the scattering and absorption properties of human tissue. Skin is the first barrier encountered by light when imaging non-invasively, and therefore a clear understanding of the way that light interacts with skin is required for progress on optical medical imaging to be made. Here we present a thorough review of the optical properties of human skin measured in-vivo and compare these to the previously collated ex-vivo measurements. Both in-vivo and ex-vivo published data show high inter- and intra-publication variability making definitive answers regarding optical properties at given wavelengths challenging. Overall, variability is highest for ex-vivo absorption measurements with differences of up to 77-fold compared with 9.6-fold for the in-vivo absorption case. The impact of this variation on optical penetration depth and transport mean free path is presented and potential causes of these inconsistencies are discussed. We propose a set of experimental controls and reporting requirements for future measurements. We conclude that a robust in-vivo dataset, measured across a broad spectrum of wavelengths, is required for the development of future technologies that significantly increase the depth of optical imaging.
Collapse
Affiliation(s)
- Kerry Setchfield
- Optics and Photonics Research Group, Faculty of Engineering, University of Nottingham, NG7 2RD, UK
| | | | - A Hamish R W Simpson
- Department of Orthopaedics, Division of Clinical and Surgical Sciences, University of Edinburgh, EH8 9YL, UK
| | - Michael G Somekh
- Optics and Photonics Research Group, Faculty of Engineering, University of Nottingham, NG7 2RD, UK
| | - Amanda J Wright
- Optics and Photonics Research Group, Faculty of Engineering, University of Nottingham, NG7 2RD, UK
| |
Collapse
|
6
|
Mota LR, Duarte IDS, Galache TR, Pretti KMDS, Neto OC, Motta LJ, Horliana ACRT, Silva DDFTD, Pavani C. Photobiomodulation Reduces Periocular Wrinkle Volume by 30%: A Randomized Controlled Trial. Photobiomodul Photomed Laser Surg 2023; 41:48-56. [PMID: 36780572 DOI: 10.1089/photob.2022.0114] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/15/2023] Open
Abstract
Objective: This study aimed to evaluate red and amber light-emitting diode protocols for facial rejuvenation at the same light dose. Background: The demand for minimally invasive cosmetic procedures to address skin aging has grown throughout the world. In vitro red and amber photobiomodulation (PBM) has been shown to improve collagen synthesis. Meanwhile, red PBM has already been studied in clinical trials; however, a comparison of the use of different wavelengths at the same light dose to reduce periocular wrinkles has not yet been performed. Methods: This split-face, randomized clinical trial recruited 137 women (40-65 years old) presenting with skin phototypes II-IV and Glogau photoaging scale types II-IV. The individuals received 10 sessions for 4 weeks of red (660 nm) and amber (590 nm) PBM (3.8 J/cm2), one at each side of the face. The outcomes, measured before and after the treatments, were the periocular wrinkle volume measured by VisioFace® RD equipment; hydration measured by the Corneometer CM 825; skin elasticity measured by the Cutometer Dual MPA 580; and quality of life determined by adapted versions of validated questionnaires [Melasma Quality of Life Scale-Brazilian Portuguese (MelasQoL-BP) and Skindex-29]. Results: There was a significant reduction in wrinkle volume after red (31.6%) and amber (29.9%) PBM. None of the treatments improved skin hydration and viscoelasticity. Both questionnaires showed improvements in participants' quality of life. Conclusions: PBM, both at red and amber wavelengths, is an effective tool for rejuvenation, producing a 30% wrinkle volume reduction. The technique has strong potential in patients with diabetes or those presenting with keloids, conditions for which highly inflammatory rejuvenating procedures are not indicated. Clinical trial registration number: REBEC-6YFCBM.
Collapse
Affiliation(s)
- Lidiane Rocha Mota
- Biophotonics Applied to Health Sciences, Postgraduate Program, Universidade Nove de Julho-UNINOVE, São Paulo, Brazil
| | | | - Thais Rodrigues Galache
- Biophotonics Applied to Health Sciences, Postgraduate Program, Universidade Nove de Julho-UNINOVE, São Paulo, Brazil
| | - Katia Maria Dos Santos Pretti
- Biophotonics Applied to Health Sciences, Postgraduate Program, Universidade Nove de Julho-UNINOVE, São Paulo, Brazil
| | | | - Lara Jansiski Motta
- Biophotonics Applied to Health Sciences, Postgraduate Program, Universidade Nove de Julho-UNINOVE, São Paulo, Brazil
| | | | | | - Christiane Pavani
- Biophotonics Applied to Health Sciences, Postgraduate Program, Universidade Nove de Julho-UNINOVE, São Paulo, Brazil
| |
Collapse
|
7
|
Kaub L, Schmitz C. More than Ninety Percent of the Light Energy Emitted by Near-Infrared Laser Therapy Devices Used to Treat Musculoskeletal Disorders Is Absorbed within the First Ten Millimeters of Biological Tissue. Biomedicines 2022; 10:biomedicines10123204. [PMID: 36551959 PMCID: PMC9775104 DOI: 10.3390/biomedicines10123204] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2022] [Revised: 12/02/2022] [Accepted: 12/07/2022] [Indexed: 12/14/2022] Open
Abstract
There is increasing interest in the application of near-infrared (NIR) laser light for the treatment of various musculoskeletal disorders. The present study thoroughly examined the physical characteristics of laser beams from two different laser therapy devices that are commercially available for the treatment of musculoskeletal disorders. Then, these laser beams were used to measure the penetration depth in various biological tissues from different animal species. The key result of the present study was the finding that for all investigated tissues, most of the initial light energy was lost in the first one to two millimeters, more than 90% of the light energy was absorbed within the first ten millimeters, and there was hardly any light energy left after 15-20 mm of tissue. Furthermore, the investigated laser therapy devices fundamentally differed in several laser beam parameters that can have an influence on how light is transmitted through tissue. Overall, the present study showed that a laser therapy device that is supposed to reach deep layers of tissue for treatments of musculoskeletal disorders should operate with a wavelength between 800 nm and 905 nm, a top-hat beam profile, and it should emit very short pulses with a large peak power.
Collapse
|
8
|
Naskar N, Liu W, Qi H, Stumper A, Fischer S, Diemant T, Behm RJ, Kaiser U, Rau S, Weil T, Chakrabortty S. A Carbon Nanodot Based Near-Infrared Photosensitizer with a Protein-Ruthenium Shell for Low-Power Photodynamic Applications. ACS APPLIED MATERIALS & INTERFACES 2022; 14:48327-48340. [PMID: 36269223 DOI: 10.1021/acsami.2c08585] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/16/2023]
Abstract
Near-infrared (NIR) light-activated photosensitization represents an encouraging therapeutic method in photodynamic therapy, especially for deep tissue penetration. In this context, two-photon activation, i.e., utilization of photons with relatively low energy but high photon flux for populating a virtual intermediate state leading to an excited state, is attractive. This concept would be highly advantageous in photodynamic therapy due to its minimal side effects. Herein, we propose that the combination of plasma protein serum albumin (HSA) containing several Ru complexes and NIR two-photon excitable carbon nanodots (Cdots), termed HSA-Ru-Cdots, provides several attractive features for enhancing singlet oxygen formation within the mitochondria of cancer cells stimulated by two-photon excitation in the NIR region. HSA-Ru-Cdot features biocompatibility, water solubility, and photostability as well as uptake into cancer cells with an endosomal release, which is an essential feature for subcellular targeting of mitochondria. The NIR two-photon excitation induced visible emission of the Cdots allows fluorescence resonance energy transfer (FRET) to excite the metal-to-ligand charge transfer of the Ru moiety, and fluorescence-lifetime imaging microscopy (FLIM) has been applied to demonstrate FRET within the cells. The NIR two-photon excitation is indirectly transferred to the Ru complexes, which leads to the production of singlet oxygen within the mitochondria of cancer cells. Consequently, we observe the destruction of filamentous mitochondrial structures into spheroid aggregates within various cancer cell lines. Cell death is induced by the long-wavelength NIR light irradiation at 810 nm with a low power density (7 mW/cm2), which could be attractive for phototherapy applications where deeper tissue penetration is crucial.
Collapse
Affiliation(s)
- Nilanjon Naskar
- Institute of Inorganic Chemistry I, Ulm University, Albert-Einstein-Allee 11, D-89081Ulm, Germany
| | - Weina Liu
- Institute of Inorganic Chemistry I, Ulm University, Albert-Einstein-Allee 11, D-89081Ulm, Germany
| | - Haoyuan Qi
- Central Facility for Materials Science Electron Microscopy, Ulm University, Albert-Einstein-Allee 11, D-89081Ulm, Germany
- Center for Advancing Electronics Dresden (cfaed) & Faculty of Chemistry and Food Chemistry, Dresden University of Technology, Mommsenstrasse 4, D-01062Dresden, Germany
| | - Anne Stumper
- Institute of Inorganic Chemistry I, Ulm University, Albert-Einstein-Allee 11, D-89081Ulm, Germany
| | - Stephan Fischer
- Institute of Pharmacology and Toxicology, University of Ulm Medical Center, Albert-Einstein-Allee 11, D-89081Ulm, Germany
| | - Thomas Diemant
- Institute of Surface Chemistry and Catalysis, Ulm University, Albert-Einstein-Allee 47, D-89081Ulm, Germany
| | - R Jürgen Behm
- Institute of Surface Chemistry and Catalysis, Ulm University, Albert-Einstein-Allee 47, D-89081Ulm, Germany
| | - Ute Kaiser
- Central Facility for Materials Science Electron Microscopy, Ulm University, Albert-Einstein-Allee 11, D-89081Ulm, Germany
| | - Sven Rau
- Institute of Inorganic Chemistry I, Ulm University, Albert-Einstein-Allee 11, D-89081Ulm, Germany
| | - Tanja Weil
- Institute of Inorganic Chemistry I, Ulm University, Albert-Einstein-Allee 11, D-89081Ulm, Germany
| | - Sabyasachi Chakrabortty
- Institute of Inorganic Chemistry I, Ulm University, Albert-Einstein-Allee 11, D-89081Ulm, Germany
- Department of Chemistry, SRM University AP Andhra Pradesh, Andhra Pradesh522502, India
| |
Collapse
|
9
|
Prabha A, Yadav J, Rani A, Singh V. Intelligent estimation of blood glucose level using wristband PPG signal and physiological parameters. Biomed Signal Process Control 2022. [DOI: 10.1016/j.bspc.2022.103876] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
|
10
|
Kandel S, Querido W, Falcon JM, Zlotnick HM, Locke RC, Stoeckl B, Patel JM, Patil CA, Mauck RL, Pleshko N. In Situ Assessment of Porcine Osteochondral Repair Tissue in the Visible-Near Infrared Spectral Region. Front Bioeng Biotechnol 2022; 10:885369. [PMID: 36082171 PMCID: PMC9445125 DOI: 10.3389/fbioe.2022.885369] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2022] [Accepted: 06/13/2022] [Indexed: 11/13/2022] Open
Abstract
Standard assessment of cartilage repair progression by visual arthroscopy can be subjective and may result in suboptimal evaluation. Visible-near infrared (Vis-NIR) fiber optic spectroscopy of joint tissues, including articular cartilage and subchondral bone, provides an objective approach for quantitative assessment of tissue composition. Here, we applied this technique in the 350-2,500 nm spectral region to identify spectral markers of osteochondral tissue during repair with the overarching goal of developing a new approach to monitor repair of cartilage defects in vivo. Full thickness chondral defects were created in Yucatan minipigs using a 5-mm biopsy punch, and microfracture (MFx) was performed as a standard technique to facilitate repair. Tissues were evaluated at 1 month (in adult pigs) and 3 months (in juvenile pigs) post-surgery by spectroscopy and histology. After euthanasia, Vis-NIR spectra were collected in situ from the defect region. Additional spectroscopy experiments were carried out in vitro to aid in spectral interpretation. Osteochondral tissues were dissected from the joint and evaluated using the conventional International Cartilage Repair Society (ICRS) II histological scoring system, which showed lower scores for the 1-month than the 3-month repair tissues. In the visible spectral region, hemoglobin absorbances at 540 and 570 nm were significantly higher in spectra from 1-month repair tissue than 3-month repair tissue, indicating a reduction of blood in the more mature repair tissue. In the NIR region, we observed qualitative differences between the two groups in spectra taken from the defect, but differences did not reach significance. Furthermore, spectral data also indicated that the hydrated environment of the joint tissue may interfere with evaluation of tissue water absorbances in the NIR region. Together, these data provide support for further investigation of the visible spectral region for assessment of longitudinal repair of cartilage defects, which would enable assessment during routine arthroscopy, particularly in a hydrated environment.
Collapse
Affiliation(s)
- Shital Kandel
- Department of Bioengineering, Temple University, Philadelphia, PA, United States
| | - William Querido
- Department of Bioengineering, Temple University, Philadelphia, PA, United States
| | - Jessica M. Falcon
- Department of Bioengineering, Temple University, Philadelphia, PA, United States
| | - Hannah M. Zlotnick
- Department of Bioengineering, University of Pennsylvania, Philadelphia, PA, United States
| | - Ryan C. Locke
- Department of Bioengineering, University of Pennsylvania, Philadelphia, PA, United States
| | - Brendan Stoeckl
- Department of Bioengineering, University of Pennsylvania, Philadelphia, PA, United States
| | - Jay M. Patel
- Department of Bioengineering, University of Pennsylvania, Philadelphia, PA, United States
- Department of Orthopedics, Emory University, Atlanta, GA, United States
| | - Chetan A. Patil
- Department of Bioengineering, Temple University, Philadelphia, PA, United States
| | - Robert L. Mauck
- Department of Bioengineering, University of Pennsylvania, Philadelphia, PA, United States
| | - Nancy Pleshko
- Department of Bioengineering, Temple University, Philadelphia, PA, United States
| |
Collapse
|
11
|
Zhao J, Kulkarni N, Dobo E, Khan MJ, Yang E, Kang D. Investigation of different wavelengths for scattering-based light sheet microscopy. BIOMEDICAL OPTICS EXPRESS 2022; 13:3882-3892. [PMID: 35991931 PMCID: PMC9352285 DOI: 10.1364/boe.459823] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/29/2022] [Revised: 05/19/2022] [Accepted: 06/07/2022] [Indexed: 05/30/2023]
Abstract
Scattering-based light sheet microscopy (sLSM) is a microscopy technique that can visualize cellular morphologic details based on the scattering signal. While sLSM was previously shown to image animal tissues ex vivo at a cellular resolution, the wavelength used was chosen based on other in vivo microscopy technologies rather than through a comparison of the sLSM imaging performance between different wavelengths. In this paper, we report the development of a multi-wavelength sLSM setup that facilitates the investigation of different wavelengths for sLSM imaging. Preliminary results of imaging human anal tissues ex vivo showed that the sLSM setup allowed for comparisons of the cellular imaging performance at the same tissue location between different wavelengths. Both the quantitative analysis of the image contrast and the visual assessment by a pathologist showed that the imaging depth increased with wavelength, and the imaging depth increase was most notable around 600 nm. The preliminary results showed that the multi-wavelength sLSM setup could be useful in identifying the optimal wavelength for the specific tissue type.
Collapse
Affiliation(s)
- Jingwei Zhao
- James C. Wyant College of Optical Sciences, University of Arizona, Tucson, Arizona 85721, USA
| | - Nachiket Kulkarni
- James C. Wyant College of Optical Sciences, University of Arizona, Tucson, Arizona 85721, USA
| | - Erika Dobo
- School of Medicine, Stanford University, Stanford, California 94305, USA
| | - Michelle J Khan
- School of Medicine, Stanford University, Stanford, California 94305, USA
| | - Eric Yang
- School of Medicine, Stanford University, Stanford, California 94305, USA
| | - Dongkyun Kang
- James C. Wyant College of Optical Sciences, University of Arizona, Tucson, Arizona 85721, USA
- Department of Biomedical Engineering, University of Arizona, Tucson, Arizona 85721, USA
| |
Collapse
|
12
|
Efficacy of Photobiomodulation in Reducing Symptomatology and Improving the Quality of Life in Patients with Xerostomia and Hyposalivation: A Randomized Controlled Trial. J Clin Med 2022; 11:jcm11123414. [PMID: 35743485 PMCID: PMC9225194 DOI: 10.3390/jcm11123414] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2022] [Revised: 06/11/2022] [Accepted: 06/13/2022] [Indexed: 02/07/2023] Open
Abstract
Objectives: To evaluate the efficacy of photobiomodulation (PBM) treatment in patients with xerostomia and hyposalivation and assess their quality of life over a one year of follow-up. Material and methods: A single-blind randomized controlled trial. A total of 60 patients with xerostomia were included (30 PBM cases and 30 placebo controls). Photobiomodulation was performed with a diode laser (810 nm, 6 J/cm2), while the controls underwent simulated treatment. One weekly session was carried out for a total of 6 weeks (total six sessions). The study parameters were recorded at baseline, after three and six weeks, and at one year post-treatment. Xerostomia was assessed using a salivary flow visual analog scale (VAS) and the Xerostomia Inventory (XI). The Hospital Anxiety and Depression (HAD) scale, Oral Health Impact Profile (OHIP-14), Pittsburgh Sleep Quality Index (PSQI) and Epworth Sleepiness Scale (ESS) were also administered. Results: The patients subjected to PBM therapy showed a significant improvement of xerostomia based on the drainage test, and of oral quality of life (p < 0.001). The depression score of the HAD (HAD-D) and the ESS showed improvement, though without reaching statistical significance (p > 0.05). The placebo group showed significant changes in the xerostomia VAS score at 6 weeks (p = 0.009), with no variations in any of the other studied parameters (p > 0.05). The beneficial effects of the diode laser in the PBM group persisted at one year post-treatment. Conclusions: Photobiomodulation with the diode laser is effective in patients with xerostomia and hyposalivation, and thus should be taken into account as a treatment option.
Collapse
|
13
|
Almulla L, Al-Naib I, Ateeq IS, Althobaiti M. Observation and motor imagery balance tasks evaluation: An fNIRS feasibility study. PLoS One 2022; 17:e0265898. [PMID: 35320324 PMCID: PMC8942212 DOI: 10.1371/journal.pone.0265898] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2021] [Accepted: 03/09/2022] [Indexed: 11/25/2022] Open
Abstract
In this study, we aimed at exploring the feasibility of functional near-infrared spectroscopy (fNIRS) for studying the observation and/or motor imagination of various postural tasks. Thirteen healthy adult subjects followed five trials of static and dynamic standing balance tasks, throughout three different experimental setups of action observation (AO), a combination of action observation and motor imagery (AO+MI), and motor imagery (MI). During static and dynamic standing tasks, both the AO+MI and MI experiments revealed that many channels in prefrontal or motor regions are significantly activated while the AO experiment showed almost no significant increase in activations in most of the channels. The contrast between static and dynamic standing tasks showed that with more demanding balance tasks, relative higher activation patterns were observed, particularly during AO and in AO+MI experiments in the frontopolar area. Moreover, the AO+MI experiment revealed a significant difference in premotor and supplementary motor cortices that are related to balance control. Furthermore, it has been observed that the AO+MI experiment induced relatively higher activation patterns in comparison to AO or MI alone. Remarkably, the results of this work match its counterpart from previous functional magnetic resonance imaging studies. Therefore, they may pave the way for using the fNIRS as a diagnostic tool for evaluating the performance of the non-physical balance training during the rehabilitation period of temporally immobilized patients.
Collapse
Affiliation(s)
- Latifah Almulla
- Biomedical Engineering Department, College of Engineering, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Ibraheem Al-Naib
- Biomedical Engineering Department, College of Engineering, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Ijlal Shahrukh Ateeq
- Biomedical Engineering Department, College of Engineering, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Murad Althobaiti
- Biomedical Engineering Department, College of Engineering, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| |
Collapse
|
14
|
Park Y, Kim H, Kim S, Cho KJ. Effect of low-level light therapy in patients with dry eye: a prospective, randomized, observer-masked trial. Sci Rep 2022; 12:3575. [PMID: 35246565 PMCID: PMC8897458 DOI: 10.1038/s41598-022-07427-6] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2021] [Accepted: 02/16/2022] [Indexed: 11/09/2022] Open
Abstract
To evaluate the efficacy of low-level light therapy (LLLT) with near-infrared light-emitting diodes (LED-LLLT) for the treatment of dry eye. 40 patients were randomly assigned with a 1:1 allocation ratio to receive LED-LLLT (LLLT group, n = 20) or placebo treatment (placebo group, n = 20). Patients in the LLLT group received LLLT twice a week for 3 weeks, for a total of 6 treatment sessions. The primary endpoint was the changes in the fluorescein corneal staining (FCS) score. The secondary endpoints were the changes in the ocular surface disease index (OSDI) score, lissamine green conjunctival staining (LGCS) scores, tear film break-up time (TBUT), Schirmer test, and the meibomian gland dysfunction (MGD) index. These were evaluated before treatment and 4 weeks after start of treatment. The mean difference of score change in primary endpoint revealed significant improvement in the LLLT group, compared to the placebo. Among secondary endpoints, LGCS, Schirmer's test, upper meibography scores showed significant improvements, while TBUT, lid debris, lid swelling, lid telangiectasia, meibomian gland secretion and expressibility scores had slight improvement without significant differences. No serious adverse events were observed. The use of LED-LLLT for the treatment of dry eye and MGD appears to be safe and beneficial.
Collapse
Affiliation(s)
- Yuli Park
- Department of Ophthalmology, Dankook University Hospital, College of Medicine, Dankook University, Cheonan, Republic of Korea
| | - Hoon Kim
- Department of Ophthalmology, Dankook University Hospital, College of Medicine, Dankook University, Cheonan, Republic of Korea
| | - Sehwan Kim
- Department of Biomedical Engineering, School of Medicine, Dankook University, Cheonan, Republic of Korea
| | - Kyong Jin Cho
- Department of Ophthalmology, Dankook University Hospital, College of Medicine, Dankook University, Cheonan, Republic of Korea.
| |
Collapse
|
15
|
Rodriguez AJ, Boonya-Ananta MT, Gonzalez M, Le VND, Fine J, Palacios C, McShane MJ, Coté GL, Ramella-Roman JC. Skin optical properties in the obese and their relation to body mass index: a review. JOURNAL OF BIOMEDICAL OPTICS 2022; 27:030902. [PMID: 35352513 PMCID: PMC8963797 DOI: 10.1117/1.jbo.27.3.030902] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/20/2021] [Accepted: 02/28/2022] [Indexed: 06/14/2023]
Abstract
SIGNIFICANCE Obesity is a worldwide epidemic contributing directly to several cardiovascular risk factors including hypertension and type 2 diabetes. Wearable devices are becoming better at quantifying biomarkers relevant for the management of health and fitness. Unfortunately, both anecdotal evidence and recent studies indicate that some wearables have higher levels of error when utilized by populations with darker skin tones and high body mass index (BMI). There is an urgent need for a better evaluation of the limits of wearable health technologies when used by obese individuals. AIMS (1) To review the current know-how on changes due to obesity in the skin epidermis, dermis, and subcutis that could affect the skin optical properties; (2) for the green wavelength range, to evaluate the difference in absorption and scattering coefficients from the abdominal skin between individuals with and without elevated BMI. The changes include alterations in layer thickness and cell size, as well as significant differences in chromophores and scatterer content, e.g., water, hemoglobin, collagen, and lipids. APPROACH We have summarized literature pertaining to changes in skin and its components in obesity and report the results of our search using articles published between years 1971 and 2020. A linear model was used to demonstrate the absorption and reduced scattering coefficient of the abdominal skin of individuals with and without elevated BMI in the green wavelength range (530 to 550 nm) that is typically found in most wearables. RESULTS The general trends indicate a decrease in absorption for both dermis and subcutis and an increase in reduced scattering for both epidermis and dermis. At 544-nm wavelength, a typical wavelength used for photoplethysmography (PPG), the absorption coefficient's relative percentage difference between high and low BMI skin, was 49% in the subcutis, 19% in the dermis, and negligible in the epidermis, whereas the reduced scattering coefficient relative difference was 21%, 29%, and 165% respectively. CONCLUSIONS These findings suggest that there could be significant errors in the output of optical devices used for monitoring health and fitness if changes due to obesity are not accounted for in their design.
Collapse
Affiliation(s)
- Andres J. Rodriguez
- Florida International University, Department of Biomedical Engineering, Miami, Florida, United States
| | | | - Mariacarla Gonzalez
- Florida International University, Department of Biomedical Engineering, Miami, Florida, United States
| | - Vinh Nguyen Du Le
- Florida International University, Department of Biomedical Engineering, Miami, Florida, United States
| | - Jesse Fine
- Texas A&M University, Department of Biomedical Engineering, College Station, Texas, United States
| | - Cristina Palacios
- Florida International University, Robert Stempel College of Public Health and Social Work, Miami, Florida, United States
| | - Mike J. McShane
- Texas A&M University, Department of Biomedical Engineering, College Station, Texas, United States
- Texas A&M University, TEES Center for Remote Health Technologies and Systems, College Station, Texas, United States
- Texas A&M University, Department of Material Science and Engineering, College Station, Texas, United States
| | - Gerard L. Coté
- Texas A&M University, Department of Biomedical Engineering, College Station, Texas, United States
- Texas A&M University, TEES Center for Remote Health Technologies and Systems, College Station, Texas, United States
| | - Jessica C. Ramella-Roman
- Florida International University, Department of Biomedical Engineering, Miami, Florida, United States
- Florida International University, Herbert Wertheim College of Medicine, Miami, Florida, United States
| |
Collapse
|
16
|
Abstract
Diffuse optical tomography using deep learning is an emerging technology that has found impressive medical diagnostic applications. However, creating an optical imaging system that uses visible and near-infrared (NIR) light is not straightforward due to photon absorption and multi-scattering by tissues. The high distortion levels caused due to these effects make the image reconstruction incredibly challenging. To overcome these challenges, various techniques have been proposed in the past, with varying success. One of the most successful techniques is the application of deep learning algorithms in diffuse optical tomography. This article discusses the current state-of-the-art diffuse optical tomography systems and comprehensively reviews the deep learning algorithms used in image reconstruction. This article attempts to provide researchers with the necessary background and tools to implement deep learning methods to solve diffuse optical tomography.
Collapse
|
17
|
Liang Z, Zhang S, Wu J, Li X, Zhuang Z, Feng Q, Chen W, Qi L. Automatic 3-D segmentation and volumetric light fluence correction for photoacoustic tomography based on optimal 3-D graph search. Med Image Anal 2021; 75:102275. [PMID: 34800786 DOI: 10.1016/j.media.2021.102275] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2021] [Revised: 10/11/2021] [Accepted: 10/15/2021] [Indexed: 01/29/2023]
Abstract
Preclinical imaging with photoacoustic tomography (PAT) has attracted wide attention in recent years since it is capable of providing molecular contrast with deep imaging depth. The automatic extraction and segmentation of the animal in PAT images is crucial for improving image analysis efficiency and enabling advanced image post-processing, such as light fluence (LF) correction for quantitative PAT imaging. Previous automatic segmentation methods are mostly two-dimensional approaches, which failed to conserve the 3-D surface continuity because the image slices were processed separately. This discontinuity problem further hampers LF correction, which, ideally, should be carried out in 3-D due to spatially diffused illumination. Here, to solve these problems, we propose a volumetric auto-segmentation method for small animal PAT imaging based on the 3-D optimal graph search (3-D GS) algorithm. The 3-D GS algorithm takes into account the relation among image slices by constructing a 3-D node-weighted directed graph, and thus ensures surface continuity. In view of the characteristics of PAT images, we improve the original 3-D GS algorithm on graph construction, solution guidance and cost assignment, such that the accuracy and smoothness of the segmented animal surface were guaranteed. We tested the performance of the proposed method by conducting in vivo nude mice imaging experiments with a commercial preclinical cross-sectional PAT system. The results showed that our method successfully retained the continuous global surface structure of the whole 3-D animal body, as well as smooth local subcutaneous tumor boundaries at different development stages. Moreover, based on the 3-D segmentation result, we were able to simulate volumetric LF distribution of the entire animal body and obtained LF corrected PAT images with enhanced structural visibility and uniform image intensity.
Collapse
Affiliation(s)
- Zhichao Liang
- School of Biomedical Engineering, Southern Medical University, Guangzhou, China; Guangdong Provincial Key Laboratory of Medical Image Processing, Southern Medical University, Guangzhou, China; Guangdong Province Engineering Laboratory for Medical Imaging and Diagnostic Technology, Southern Medical University, Guangzhou, China
| | - Shuangyang Zhang
- School of Biomedical Engineering, Southern Medical University, Guangzhou, China; Guangdong Provincial Key Laboratory of Medical Image Processing, Southern Medical University, Guangzhou, China; Guangdong Province Engineering Laboratory for Medical Imaging and Diagnostic Technology, Southern Medical University, Guangzhou, China
| | - Jian Wu
- School of Biomedical Engineering, Southern Medical University, Guangzhou, China; Guangdong Provincial Key Laboratory of Medical Image Processing, Southern Medical University, Guangzhou, China; Guangdong Province Engineering Laboratory for Medical Imaging and Diagnostic Technology, Southern Medical University, Guangzhou, China
| | - Xipan Li
- School of Biomedical Engineering, Southern Medical University, Guangzhou, China; Guangdong Provincial Key Laboratory of Medical Image Processing, Southern Medical University, Guangzhou, China; Guangdong Province Engineering Laboratory for Medical Imaging and Diagnostic Technology, Southern Medical University, Guangzhou, China
| | - Zhijian Zhuang
- School of Biomedical Engineering, Southern Medical University, Guangzhou, China; Guangdong Provincial Key Laboratory of Medical Image Processing, Southern Medical University, Guangzhou, China; Guangdong Province Engineering Laboratory for Medical Imaging and Diagnostic Technology, Southern Medical University, Guangzhou, China
| | - Qianjin Feng
- School of Biomedical Engineering, Southern Medical University, Guangzhou, China; Guangdong Provincial Key Laboratory of Medical Image Processing, Southern Medical University, Guangzhou, China; Guangdong Province Engineering Laboratory for Medical Imaging and Diagnostic Technology, Southern Medical University, Guangzhou, China
| | - Wufan Chen
- School of Biomedical Engineering, Southern Medical University, Guangzhou, China; Guangdong Provincial Key Laboratory of Medical Image Processing, Southern Medical University, Guangzhou, China; Guangdong Province Engineering Laboratory for Medical Imaging and Diagnostic Technology, Southern Medical University, Guangzhou, China
| | - Li Qi
- School of Biomedical Engineering, Southern Medical University, Guangzhou, China; Guangdong Provincial Key Laboratory of Medical Image Processing, Southern Medical University, Guangzhou, China; Guangdong Province Engineering Laboratory for Medical Imaging and Diagnostic Technology, Southern Medical University, Guangzhou, China.
| |
Collapse
|
18
|
Chen T, Liu L, Ma X, Zhang Y, Liu H, Zheng R, Ren J, Zhou H, Ren Y, Gao R, Chen N, Zheng H, Song L, Liu C. Dedicated photoacoustic imaging instrument for human periphery blood vessels: A new paradigm for understanding the vascular health. IEEE Trans Biomed Eng 2021; 69:1093-1100. [PMID: 34543187 DOI: 10.1109/tbme.2021.3113764] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
A novel photoacoustic imaging system based on a semi-ring transducer array is proposed to imageperipheralbloodvessels. The system's penetration depth is deep (~15 mm) with high spatial (~200 m) and temporal resolution. In a clinical study, volumetric photoacoustic data of limbs were obtained within the 50s (for a FOV of 15 cm4 cm) with the volunteers in the standing and sitting posture. Compared to the previous studies, our system has many advantages, including (1) Larger field of view; (2) Finer elevational and in-plane resolutions; (3) Enhanced 3D visualization of peripheralvascular networks; (4) Compact size and better portability. The 3D visualization and cross-sectional images of five healthy volunteers clearly show the vascular network and the system's ability to image submillimeter blood vessels. This high-resolution PA system has great potential for imaging human periphery vasculatures noninvasively in clinical research.
Collapse
|
19
|
Golež A, Frangež I, Cankar K, Frangež HB, Ovsenik M, Nemeth L. Effects of low-level light therapy on xerostomia related to hyposalivation: a systematic review and meta-analysis of clinical trials. Lasers Med Sci 2021; 37:745-758. [PMID: 34409539 DOI: 10.1007/s10103-021-03392-0] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2020] [Accepted: 07/26/2021] [Indexed: 02/06/2023]
Abstract
Hyposalivation is a condition represented by a reduced salivary flow and may include symptoms such as mouth dryness (xerostomia), loss of taste, pain, dysphagia, and dysphonia, all of which greatly affect an individual's quality of life.The aim of the present study was to systematically review the effects of low-level light therapy irradiation (photobiomodulation) on salivary gland function in patients with hyposalivation.The main question of the systematic review was: "Does low-level light irradiation therapy of the salivary glands affect salivary flow rate or indicators of salivary function (ion and protein concentrations) in patients with xerostomia or hyposalivation?" The question was based on the PICO (participant, intervention, control, outcome) principle and followed the PRISMA guidelines. Databases were explored and papers published between the years 1997 and 2020 were reviewed for the following Mesh-term keywords and their corresponding entry terms in different combinations: "Low-level light therapy," "Xerostomia," "Saliva," "Salivary glands," "Salivation."The initial sample consisted of 220 articles. Of those, 47 articles were used for full-text analysis and 18 were used for a systematic review, 14 were used in meta-analysis. According to their individual quality, most articles were classified as high quality of evidence according to the GRADE score. Meta-analysis of the evidence observed increase of unstimulated salivary flow 0.51 SMD compared to placebo (95% CI: 0.16-0.86), I2 = 50%, p = 0.005.The findings of our review revealed evidence of a beneficial effect of photobiomodulation therapy on salivary gland function. The therapy alleviates xerostomia and hyposalivation. However, these effects are reported short term only and did not induce lasting effects of photobiomodulation therapy on patients' quality of life.
Collapse
Affiliation(s)
- Aljaž Golež
- Institute of Physiology, Faculty of Medicine, University of Ljubljana, Zaloska cesta 4, Ljubljana, Slovenia
| | - Igor Frangež
- Department for Surgical Infections, University Medical Center Ljubljana, Zaloska cesta 2, 1000, Ljubljana, Slovenia.,Department of Surgery, Faculty of Medicine, University of Ljubljana, Zaloska cesta 7, Ljubljana, Slovenia
| | - Ksenija Cankar
- Institute of Physiology, Faculty of Medicine, University of Ljubljana, Zaloska cesta 4, Ljubljana, Slovenia
| | - Helena Ban Frangež
- Department of Gynaecology and Obstetrics, Faculty of Medicine, University of Ljubljana, Slajmerjeva 3, 1000, Ljubljana, Slovenia.,Department of Obstetrics and Gynaecology, University Medical Center Ljubljana, Slajmerjeva 3, 1000, Ljubljana, Slovenia
| | - Maja Ovsenik
- Department of Orthodontics and Dentofacial Orthopaedics, Faculty of Medicine, University of Ljubljana, Hrvatski trg 6, Ljubljana, Slovenia
| | - Lidija Nemeth
- Department of Dental Diseases and Normal Dental Morphology, Faculty of Medicine, University of Ljubljana, Hrvatski trg 6, Ljubljana, Slovenia.,Division of Stomatology, University Medical Centre Ljubljana, Stomatoloska klinika, Hrvatski trg 6, 1000, Ljubljana, Slovenia
| |
Collapse
|
20
|
Giovannella M, Urtane E, Zanoletti M, Karadeniz U, Rubins U, Weigel UM, Marcinkevics Z, Durduran T. Microvascular blood flow changes of the abductor pollicis brevis muscle during sustained static exercise. BIOMEDICAL OPTICS EXPRESS 2021; 12:4235-4248. [PMID: 34457411 PMCID: PMC8367267 DOI: 10.1364/boe.427885] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/20/2021] [Revised: 06/09/2021] [Accepted: 06/09/2021] [Indexed: 06/13/2023]
Abstract
A practical assessment of the general health and microvascular function of the palm muscle, abductor pollicis brevis (APB), is important for the diagnosis of different conditions. In this study, we have developed a protocol and a probe to study microvascular blood flow using near-infrared diffuse correlation spectroscopy (DCS) in APB during and after thumb abduction at 55% of maximum voluntary contraction (MVC). Near-infrared time resolved spectroscopy (TRS) was also used to characterize the baseline optical and hemodynamic properties. Thirteen (n=13) subjects were enrolled and subdivided in low MVC (N=6, MVC<2.3 kg) and high MVC (N=7, MVC≥2.3 kg) groups. After ruling out significant changes in the systemic physiology that influence the muscle hemodynamics, we have observed that the high MVC group showed a 56% and 36% decrease in the blood flow during exercise, with respect to baseline, in the long and short source-detector (SD) separations (p=0.031 for both). No statistical differences were shown for the low MVC group (p=1 for short and p=0.15 for long SD). These results suggest that the mechanical occlusion, due to increased intramuscular pressure, exceeded the vasodilation elicited by the higher metabolic demand. Also, blood flow changes during thumb contraction negatively correlated (R=-0.7, p<0.01) with the absolute force applied by each subject. Furthermore, after the exercise, muscular blood flow increased significantly immediately after thumb contractions in both high and low MVC groups, with respect to the recorded values during the exercise (p=0.031). An increase of 251% (200%) was found for the long (short) SD in the low MVC group. The high MVC groups showed a significant 90% increase in blood flow only after 80 s from the start of the protocol. For both low and high MVC groups, blood flow recovered to baseline values within 160 s from starting the exercise. In conclusion, DCS allows the study of the response of a small muscle to static exercise and can be potentially used in multiple clinical conditions scenarios for assessing microvascular health.
Collapse
Affiliation(s)
- Martina Giovannella
- ICFO-Institut de Ciències Fotòniques, The Barcelona Institute of Science and Technology, 08860 Castelldefels (Barcelona), Spain
| | - Evelina Urtane
- Faculty of Biology, Department of Human and Animal Physiology, University of Latvia, Kronvalda Blvd. 4, LV 1586, Riga, Latvia
| | - Marta Zanoletti
- ICFO-Institut de Ciències Fotòniques, The Barcelona Institute of Science and Technology, 08860 Castelldefels (Barcelona), Spain
| | - Umut Karadeniz
- ICFO-Institut de Ciències Fotòniques, The Barcelona Institute of Science and Technology, 08860 Castelldefels (Barcelona), Spain
| | - Uldis Rubins
- Institute of Atomic Physics and Spectroscopy, University of Latvia, 19 Rainis Blvd., Riga LV- 1586, Latvia
| | - Udo M. Weigel
- HemoPhotonics S.L., Av. Carl Friedrich Gauss Num. 3, 08860 Castelldefels (Barcelona), Spain
| | - Zbignevs Marcinkevics
- Faculty of Biology, Department of Human and Animal Physiology, University of Latvia, Kronvalda Blvd. 4, LV 1586, Riga, Latvia
| | - Turgut Durduran
- ICFO-Institut de Ciències Fotòniques, The Barcelona Institute of Science and Technology, 08860 Castelldefels (Barcelona), Spain
- Institució Catalana de Recerca i Estudis Avançats (ICREA), 08010 Barcelona, Spain
| |
Collapse
|
21
|
Macdonald CM, Sridhar S, Do HTX, Luna-Labrador J, Adel M, Da Silva A. Controlling the optical pathlength in continuous-wave reflectance spectroscopy using polarization. BIOMEDICAL OPTICS EXPRESS 2021; 12:4401-4413. [PMID: 34457421 PMCID: PMC8367255 DOI: 10.1364/boe.426627] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/01/2021] [Revised: 06/12/2021] [Accepted: 06/13/2021] [Indexed: 05/31/2023]
Abstract
We investigate potential improvements of continuous-wave diffuse reflectance spectroscopy within highly scattering media by employing polarization gating. Simulations are used to show the extent at which the effective optical pathlength varies in a typical scattering medium as a function of the optical wavelength, the total level of absorption, and the selected polarization channels, including elliptical and circular polarization channels. Experiments then demonstrate that a wavelength dependent polarization gating scheme may reduce the prior knowledge required to solve the problem of chromophore quantification. This is achieved by finding combinations of polarization channels which have similar effective optical pathlengths through the medium at each wavelength.
Collapse
Affiliation(s)
- Callum M. Macdonald
- Aix Marseille Univ, CNRS, Centrale Marseille, Institut Fresnel, Marseille, France
- Department of Medical Physics and Biomedical Engineering, University College London, Gower Street, London WC1E 6BT, UK
| | - Susmita Sridhar
- Aix Marseille Univ, CNRS, Centrale Marseille, Institut Fresnel, Marseille, France
| | - Hung T. X. Do
- Aix Marseille Univ, CNRS, Centrale Marseille, Institut Fresnel, Marseille, France
| | - Javier Luna-Labrador
- Aix Marseille Univ, CNRS, Centrale Marseille, Institut Fresnel, Marseille, France
| | - Mouloud Adel
- Aix Marseille Univ, CNRS, Centrale Marseille, Institut Fresnel, Marseille, France
| | - Anabela Da Silva
- Aix Marseille Univ, CNRS, Centrale Marseille, Institut Fresnel, Marseille, France
| |
Collapse
|
22
|
Cortese L, Lo Presti G, Zanoletti M, Aranda G, Buttafava M, Contini D, Dalla Mora A, Dehghani H, Di Sieno L, de Fraguier S, Hanzu FA, Mora Porta M, Nguyen-Dinh A, Renna M, Rosinski B, Squarcia M, Tosi A, Weigel UM, Wojtkiewicz S, Durduran T. The LUCA device: a multi-modal platform combining diffuse optics and ultrasound imaging for thyroid cancer screening. BIOMEDICAL OPTICS EXPRESS 2021; 12:3392-3409. [PMID: 34221667 PMCID: PMC8221941 DOI: 10.1364/boe.416561] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/05/2021] [Revised: 05/07/2021] [Accepted: 05/07/2021] [Indexed: 05/07/2023]
Abstract
We present the LUCA device, a multi-modal platform combining eight-wavelength near infrared time resolved spectroscopy, sixteen-channel diffuse correlation spectroscopy and a clinical ultrasound in a single device. By simultaneously measuring the tissue hemodynamics and performing ultrasound imaging, this platform aims to tackle the low specificity and sensitivity of the current thyroid cancer diagnosis techniques, improving the screening of thyroid nodules. Here, we show a detailed description of the device, components and modules. Furthermore, we show the device tests performed through well established protocols for phantom validation, and the performance assessment for in vivo. The characterization tests demonstrate that LUCA device is capable of performing high quality measurements, with a precision in determining in vivo tissue optical and dynamic properties of better than 3%, and a reproducibility of better than 10% after ultrasound-guided probe repositioning, even with low photon count-rates, making it suitable for a wide variety of clinical applications.
Collapse
Affiliation(s)
- Lorenzo Cortese
- ICFO-Institut de Ciències Fotòniques, The Barcelona Institute of Science and Technology, 08860 Castelldefels (Barcelona), Spain
- These authors equally contributed to this work. Authors are listed in alphabetical order except for the first three and the last
| | - Giuseppe Lo Presti
- ICFO-Institut de Ciències Fotòniques, The Barcelona Institute of Science and Technology, 08860 Castelldefels (Barcelona), Spain
- These authors equally contributed to this work. Authors are listed in alphabetical order except for the first three and the last
| | - Marta Zanoletti
- Politecnico di Milano, Dipartimento di Fisica, 20133 Milano, Italy
| | - Gloria Aranda
- IDIBAPS, Fundació Clínic per la Recerca Biomèdica, Barcelona, Spain
| | - Mauro Buttafava
- Politecnico di Milano, Dipartimento di Elettronica Informazione e Bioingegneria, 20133 Milano, Italy
| | - Davide Contini
- Politecnico di Milano, Dipartimento di Fisica, 20133 Milano, Italy
| | | | - Hamid Dehghani
- University of Birmingham, School of Computer Science, Edgbaston, Birmingham, B15 2TT, UK
| | - Laura Di Sieno
- Politecnico di Milano, Dipartimento di Fisica, 20133 Milano, Italy
| | | | - Felicia A. Hanzu
- IDIBAPS, Fundació Clínic per la Recerca Biomèdica, Barcelona, Spain
- Endocrinology and Nutrition Department, Hospital Clínic of Barcelona, Barcelona, Spain
- Centro de Investigación Biomèdica en Red Diabetes y Enfermedades Metabólicas Asociadas (CIBERDEM), Spain
| | - Mireia Mora Porta
- IDIBAPS, Fundació Clínic per la Recerca Biomèdica, Barcelona, Spain
- Endocrinology and Nutrition Department, Hospital Clínic of Barcelona, Barcelona, Spain
- Centro de Investigación Biomèdica en Red Diabetes y Enfermedades Metabólicas Asociadas (CIBERDEM), Spain
| | | | - Marco Renna
- Politecnico di Milano, Dipartimento di Elettronica Informazione e Bioingegneria, 20133 Milano, Italy
- Athinoula A. Martinos Center for Biomedical Imaging, MGH, Harvard Medical School, Charlestown, MA 02129, USA
| | | | - Mattia Squarcia
- IDIBAPS, Fundació Clínic per la Recerca Biomèdica, Barcelona, Spain
- Neuroradiology Department, Hospital Clínic of Barcelona, Barcelona, Spain
| | - Alberto Tosi
- Politecnico di Milano, Dipartimento di Elettronica Informazione e Bioingegneria, 20133 Milano, Italy
| | - Udo M. Weigel
- HemoPhotonics S.L., 08860 Castelldefels (Barcelona), Spain
| | - Stanislaw Wojtkiewicz
- University of Birmingham, School of Computer Science, Edgbaston, Birmingham, B15 2TT, UK
| | - Turgut Durduran
- ICFO-Institut de Ciències Fotòniques, The Barcelona Institute of Science and Technology, 08860 Castelldefels (Barcelona), Spain
- Institució Catalana de Recerca i Estudis Avançats (ICREA), 08015 Barcelona, Spain
| |
Collapse
|
23
|
The Use of Supercontinuum Laser Sources in Biomedical Diffuse Optics: Unlocking the Power of Multispectral Imaging. APPLIED SCIENCES-BASEL 2021. [DOI: 10.3390/app11104616] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
Abstract
Optical techniques based on diffuse optics have been around for decades now and are making their way into the day-to-day medical applications. Even though the physics foundations of these techniques have been known for many years, practical implementation of these technique were hindered by technological limitations, mainly from the light sources and/or detection electronics. In the past 20 years, the developments of supercontinuum laser (SCL) enabled to unlock some of these limitations, enabling the development of system and methodologies relevant for medical use, notably in terms of spectral monitoring. In this review, we focus on the use of SCL in biomedical diffuse optics, from instrumentation and methods developments to their use for medical applications. A total of 95 publications were identified, from 1993 to 2021. We discuss the advantages of the SCL to cover a large spectral bandwidth with a high spectral power and fast switching against the disadvantages of cost, bulkiness, and long warm up times. Finally, we summarize the utility of using such light sources in the development and application of diffuse optics in biomedical sciences and clinical applications.
Collapse
|
24
|
Mosca S, Dey P, Salimi M, Gardner B, Palombo F, Stone N, Matousek P. Spatially Offset Raman Spectroscopy-How Deep? Anal Chem 2021; 93:6755-6762. [PMID: 33886282 DOI: 10.1021/acs.analchem.1c00490] [Citation(s) in RCA: 26] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
Spatially offset Raman spectroscopy (SORS) is a technique for interrogating the subsurface composition of turbid samples noninvasively. This study generically addresses a fundamental question relevant to a wide range of SORS studies, which is how deep SORS probes for any specific spatial offset when analyzing a turbid sample or, in turn, what magnitude of spatial offset one should select to probe a specific depth. This issue is addressed by using Monte Carlo simulations, under the assumption of negligible absorption, which establishes that the key parameter governing the extent of the probed zone for a point-like illumination and point-like collection SORS geometry is the reduced scattering coefficient of the medium. This can either be deduced from literature data or directly estimated from a SORS measurement by evaluating the Raman intensity profile from multiple spatial offsets. Once this is known, the extent of the probed zone can be determined for any specific SORS spatial offset using the Monte Carlo simulation results presented here. The proposed method was tested using experimental data on stratified samples by analyzing the signal detected from a thin layer that was moved through a stack of layers using both non-absorbing and absorbing samples. The proposed simple methodology provides important additional information on SORS measurements with direct relevance to a wide range of SORS applications including biomedical, pharmaceutical, security, forensics, and cultural heritage.
Collapse
Affiliation(s)
- Sara Mosca
- Central Laser Facility, Research Complex at Harwell, STFC Rutherford Appleton Laboratory, UK Research and Innovation, Harwell Campus, Didcot OX11 0QX, United Kingdom
| | - Priyanka Dey
- School of Physics and Astronomy, University of Exeter, Exeter EX4 4QL, United Kingdom
| | - Marzieh Salimi
- School of Physics and Astronomy, University of Exeter, Exeter EX4 4QL, United Kingdom
| | - Benjamin Gardner
- School of Physics and Astronomy, University of Exeter, Exeter EX4 4QL, United Kingdom
| | - Francesca Palombo
- School of Physics and Astronomy, University of Exeter, Exeter EX4 4QL, United Kingdom
| | - Nick Stone
- School of Physics and Astronomy, University of Exeter, Exeter EX4 4QL, United Kingdom
| | - Pavel Matousek
- Central Laser Facility, Research Complex at Harwell, STFC Rutherford Appleton Laboratory, UK Research and Innovation, Harwell Campus, Didcot OX11 0QX, United Kingdom
| |
Collapse
|
25
|
Pirovano I, Porcelli S, Re R, Spinelli L, Contini D, Marzorati M, Torricelli A. Effect of adipose tissue thickness and tissue optical properties on the differential pathlength factor estimation for NIRS studies on human skeletal muscle. BIOMEDICAL OPTICS EXPRESS 2021; 12:571-587. [PMID: 33659090 PMCID: PMC7899498 DOI: 10.1364/boe.412447] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/14/2020] [Revised: 12/04/2020] [Accepted: 12/13/2020] [Indexed: 06/12/2023]
Abstract
We propose a quantitative and systematic investigation of the differential pathlength factor (DPF) behavior for skeletal muscles and its dependence on different factors, such as the subcutaneous adipose tissue thickness (ATT), the variations of the tissue absorption (µa ) and reduced scattering (µ's ) coefficients, and the source-detector distance. A time domain (TD) NIRS simulation study is performed in a two-layer geometry mimicking a human skeletal muscle with an overlying adipose tissue layer. The DPF decreases when µa increases, while it increases when µ's increases. Moreover, a positive correlation between DPF and ATT is found. These results are supported by an in-vivo TD NIRS study on vastus lateralis and biceps brachii muscles of eleven subjects at rest, showing a high inter-subject and inter-muscle variability.
Collapse
Affiliation(s)
| | - Simone Porcelli
- Istituto di Tecnologie Biomediche, Consiglio Nazionale delle Ricerche, Segrate, Milan, Italy
- Dipartimento di Medicina Molecolare, Università di Pavia, Pavia, Italy
| | - Rebecca Re
- Dipartimento di Fisica, Politecnico di Milano, Milan, Italy
- Istituto di Fotonica e Nanotecnologie, Consiglio Nazionale delle Ricerche, Milan, Italy
| | - Lorenzo Spinelli
- Istituto di Fotonica e Nanotecnologie, Consiglio Nazionale delle Ricerche, Milan, Italy
| | - Davide Contini
- Dipartimento di Fisica, Politecnico di Milano, Milan, Italy
| | - Mauro Marzorati
- Istituto di Tecnologie Biomediche, Consiglio Nazionale delle Ricerche, Segrate, Milan, Italy
| | - Alessandro Torricelli
- Dipartimento di Fisica, Politecnico di Milano, Milan, Italy
- Istituto di Fotonica e Nanotecnologie, Consiglio Nazionale delle Ricerche, Milan, Italy
| |
Collapse
|
26
|
Yu S, Xu J, Shang X, Zheng W, Huang P, Li R, Tu D, Chen X. A Dual-Excitation Decoding Strategy Based on NIR Hybrid Nanocomposites for High-Accuracy Thermal Sensing. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2020; 7:2001589. [PMID: 33101860 PMCID: PMC7578878 DOI: 10.1002/advs.202001589] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/29/2020] [Revised: 06/18/2020] [Indexed: 05/04/2023]
Abstract
Optical thermal sensing holds great promise for disease theranostics. However, traditional ratiometric thermometry methods, in which intensity ratio of two nonoverlapping emissions is defined as the thermosensitive parameter, may have a limited accuracy in temperature read-out due to the deleterious interference from wavelength- and temperature-dependent photon attenuation in tissue. To overcome this limitation, a dual-excitation decoding strategy based on NIR hybrid nanocomposites comprising self-assembled quantum dots (QDs) and Nd3+ doped fluoride nanocrystals (NCs) is proposed for thermal sensing. Upon excitation at 808 nm, the intensity ratio of two emissions at identical wavelength (1057 nm) from QDs and NCs, respectively, is defined as the thermometric parameter R. By employing another 830 nm laser beam following the same optical path as 808 nm laser to exclusively excite QDs, the two overlapping emissions can be easily decoded. The acquired R proves to be inert to the detection depth in tissue, with a minimized temperature reading error of ≈2.3 °C at 35 °C (at a depth of ≈1.1 mm), while the traditional thermometry mode based on the nonoverlapping 1025 and 863 nm emissions may exhibit a large error of ≈43.0 °C. The insights provided by this work pave the way toward high-accuracy deep-tissue biosensing.
Collapse
Affiliation(s)
- Shaohua Yu
- CAS Key Laboratory of Design and Assembly of Functional NanostructuresState Key Laboratory of Structural Chemistry, and Fujian Key Laboratory of NanomaterialsFujian Institute of Research on the Structure of MatterChinese Academy of SciencesFuzhouFujian350002China
- University of Chinese Academy of SciencesBeijing100049China
| | - Jin Xu
- CAS Key Laboratory of Design and Assembly of Functional NanostructuresState Key Laboratory of Structural Chemistry, and Fujian Key Laboratory of NanomaterialsFujian Institute of Research on the Structure of MatterChinese Academy of SciencesFuzhouFujian350002China
- Fujian Science & Technology Innovation Laboratory for Optoelectronic Information of ChinaFuzhouFujian350108China
| | - Xiaoying Shang
- CAS Key Laboratory of Design and Assembly of Functional NanostructuresState Key Laboratory of Structural Chemistry, and Fujian Key Laboratory of NanomaterialsFujian Institute of Research on the Structure of MatterChinese Academy of SciencesFuzhouFujian350002China
| | - Wei Zheng
- CAS Key Laboratory of Design and Assembly of Functional NanostructuresState Key Laboratory of Structural Chemistry, and Fujian Key Laboratory of NanomaterialsFujian Institute of Research on the Structure of MatterChinese Academy of SciencesFuzhouFujian350002China
- Fujian Science & Technology Innovation Laboratory for Optoelectronic Information of ChinaFuzhouFujian350108China
| | - Ping Huang
- CAS Key Laboratory of Design and Assembly of Functional NanostructuresState Key Laboratory of Structural Chemistry, and Fujian Key Laboratory of NanomaterialsFujian Institute of Research on the Structure of MatterChinese Academy of SciencesFuzhouFujian350002China
- Fujian Science & Technology Innovation Laboratory for Optoelectronic Information of ChinaFuzhouFujian350108China
| | - Renfu Li
- CAS Key Laboratory of Design and Assembly of Functional NanostructuresState Key Laboratory of Structural Chemistry, and Fujian Key Laboratory of NanomaterialsFujian Institute of Research on the Structure of MatterChinese Academy of SciencesFuzhouFujian350002China
- Fujian Science & Technology Innovation Laboratory for Optoelectronic Information of ChinaFuzhouFujian350108China
| | - Datao Tu
- CAS Key Laboratory of Design and Assembly of Functional NanostructuresState Key Laboratory of Structural Chemistry, and Fujian Key Laboratory of NanomaterialsFujian Institute of Research on the Structure of MatterChinese Academy of SciencesFuzhouFujian350002China
- Fujian Science & Technology Innovation Laboratory for Optoelectronic Information of ChinaFuzhouFujian350108China
| | - Xueyuan Chen
- CAS Key Laboratory of Design and Assembly of Functional NanostructuresState Key Laboratory of Structural Chemistry, and Fujian Key Laboratory of NanomaterialsFujian Institute of Research on the Structure of MatterChinese Academy of SciencesFuzhouFujian350002China
- University of Chinese Academy of SciencesBeijing100049China
- Fujian Science & Technology Innovation Laboratory for Optoelectronic Information of ChinaFuzhouFujian350108China
| |
Collapse
|
27
|
Rehman AU, Ahmad I, Qureshi SA. Biomedical Applications of Integrating Sphere: A Review. Photodiagnosis Photodyn Ther 2020; 31:101712. [DOI: 10.1016/j.pdpdt.2020.101712] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2019] [Revised: 02/05/2020] [Accepted: 03/02/2020] [Indexed: 10/24/2022]
|
28
|
Almulla L, Al-Naib I, Althobaiti M. Hemodynamic responses during standing and sitting activities: a study toward fNIRS-BCI. Biomed Phys Eng Express 2020; 6:055005. [PMID: 33444236 DOI: 10.1088/2057-1976/aba102] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
In this paper, we utilized functional near-infrared spectroscopy (fNIRS) technology to examine the hemodynamic responses in the motor cortex for two conditions, namely standing and sitting tasks. Nine subjects performed five trials of standing and sitting (SAS) tasks with both real movements and imagery thinking of SAS. A group level of statistical parametric mapping (SPM) analysis during these tasks showed bilateral activation of oxy-hemoglobin for both real movements and imagery experiments. Interestingly, the SPM analysis clearly revealed that the sitting tasks induced a higher oxy-hemoglobin level activation compared to the standing task. Remarkably, this finding is persistent across the 22 measured channels at the individual and group levels for both experiments. Furthermore, six features were extracted from pre-processed HbO signals and the performance of four different classifiers was examined in order to test the viability of using SAS tasks in future fNIRS-brain-computer interface (fNIRS-BCI) systems. In particular, two features-combination tests revealed that the signal slope with signal variance represents one of the three best two-combined features for its consistency in providing high accuracy results for both real and imagery experiments. This study shows the potential of implementing such tasks into the fNIRS-BCI system. In the future, the results of this work could pave the way towards the application of fNIRS-BCI in lower limb rehabilitation.
Collapse
Affiliation(s)
- Latifah Almulla
- Biomedical Engineering Department, College of Engineering, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | | | | |
Collapse
|
29
|
Rapp TL, DeForest CA. Visible Light-Responsive Dynamic Biomaterials: Going Deeper and Triggering More. Adv Healthc Mater 2020; 9:e1901553. [PMID: 32100475 DOI: 10.1002/adhm.201901553] [Citation(s) in RCA: 44] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2019] [Revised: 01/06/2020] [Indexed: 12/17/2022]
Abstract
Photoresponsive materials have been widely used in vitro for controlled therapeutic delivery and to direct 4D cell fate. Extension of the approaches into a bodily setting requires use of low-energy, long-wavelength light that penetrates deeper into and through complex tissue. This review details recent reports of photoactive small molecules and proteins that absorb visible and/or near-infrared light, opening the door to exciting new applications in multiplexed and in vivo regulation.
Collapse
Affiliation(s)
- Teresa L. Rapp
- Department of Chemical Engineering University of Washington 3781 Okanogan Lane NE Seattle WA 98195 USA
| | - Cole A. DeForest
- Department of Chemical Engineering University of Washington 3781 Okanogan Lane NE Seattle WA 98195 USA
- Department of Bioengineering University of Washington 3720 15th Ave NE Seattle WA 98105 USA
- Institute for Stem Cell & Regenerative Medicine University of Washington 850 Republican Street Seattle WA 98109 USA
- Molecular Engineering & Sciences Institute University of Washington 3946 W Stevens Way NE Seattle WA 98195 USA
| |
Collapse
|
30
|
Fasciani I, Petragnano F, Aloisi G, Marampon F, Rossi M, Coppolino MF, Rossi R, Longoni B, Scarselli M, Maggio R. A New Threat to Dopamine Neurons: The Downside of Artificial Light. Neuroscience 2020; 432:216-228. [PMID: 32142863 DOI: 10.1016/j.neuroscience.2020.02.047] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2019] [Revised: 02/26/2020] [Accepted: 02/27/2020] [Indexed: 12/17/2022]
Abstract
Growing awareness of adverse impacts of artificial light on human health has led to recognize light pollution as a significant global environmental issue. Despite, a large number of studies in rodent and monkey models of Parkinson's disease have reported that near infrared light has neuroprotective effects on dopaminergic neurons, recent findings have shown that prolonged exposure of rodents and birds to fluorescent artificial light results in an increase of neuromelanin granules in substantia nigra and loss of dopaminergic neurons. The observed detrimental effect seems to be dependent on a direct effect of light on the substantia nigra rather than a secondary effect of the alterations of circadian rhythms. Moreover, inferences from animal models to human studies have shown a positive correlation between the prevalence of Parkinson's disease and light pollution. The present article discusses experimental evidence supporting a potentially deleterious impact of light on dopaminergic neurons and highlights the mechanisms whereby light might damage neuronal tissue. Moreover, it analyses epidemiological evidence that suggests light pollution to be an environmental risk factor for Parkinson's disease.
Collapse
Affiliation(s)
- Irene Fasciani
- Department of Biotechnological and Applied Clinical Sciences, University of L'Aquila, L'Aquila, Italy
| | - Francesco Petragnano
- Department of Biotechnological and Applied Clinical Sciences, University of L'Aquila, L'Aquila, Italy
| | - Gabriella Aloisi
- Department of Biotechnological and Applied Clinical Sciences, University of L'Aquila, L'Aquila, Italy
| | - Francesco Marampon
- Department of Radiotherapy, Policlinico Umberto I, Sapienza University of Rome, Rome, Italy
| | - Mario Rossi
- Institute of Molecular Cell and Systems Biology, University of Glasgow, Glasgow, UK
| | - Maria Francesca Coppolino
- Department of Biotechnological and Applied Clinical Sciences, University of L'Aquila, L'Aquila, Italy
| | - Rodolfo Rossi
- Ph D Programme in Neuroscience, University Tor Vergata, Rome, Italy
| | - Biancamaria Longoni
- Department of Translational Research and New Technologies in Medicine and Surgery, University of Pisa, Pisa, Italy
| | - Marco Scarselli
- Department of Translational Research and New Technologies in Medicine and Surgery, University of Pisa, Pisa, Italy
| | - Roberto Maggio
- Department of Biotechnological and Applied Clinical Sciences, University of L'Aquila, L'Aquila, Italy.
| |
Collapse
|
31
|
Mosca S, Lanka P, Stone N, Konugolu Venkata Sekar S, Matousek P, Valentini G, Pifferi A. Optical characterization of porcine tissues from various organs in the 650-1100 nm range using time-domain diffuse spectroscopy. BIOMEDICAL OPTICS EXPRESS 2020; 11:1697-1706. [PMID: 32206436 PMCID: PMC7075607 DOI: 10.1364/boe.386349] [Citation(s) in RCA: 28] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/03/2020] [Revised: 02/14/2020] [Accepted: 02/14/2020] [Indexed: 05/10/2023]
Abstract
We present a systematic characterization of the optical properties (µa and µs') of nine representative ex vivo porcine tissues over a broadband spectrum (650-1100 nm). We applied time-resolved diffuse optical spectroscopy measurements for recovering the optical properties of porcine tissues depicting a realistic representation of the tissue heterogeneity and morphology likely to be found in different ex vivo tissues. The results demonstrate a large spectral and inter-tissue variation of optical properties. The data can be exploited for planning or simulating ex vivo experiments with various biophotonics techniques, or even to construct artificial structures mimicking specific pathologies exploiting the wide assortment in optical properties.
Collapse
Affiliation(s)
- Sara Mosca
- Central Laser Facility, Research Complex at Harwell, STFC Rutherford Appleton Laboratory, UK Research and Innovation, Harwell Campus, OX11 0QX, United Kingdom
- These authors contributed equally to this research
| | - Pranav Lanka
- Dipartimento di Fisica, Politecnico di Milano, Milano, Italy
- These authors contributed equally to this research
| | - Nick Stone
- School of Physics and Astronomy, University of Exeter, Exeter, EX4 4QL, United Kingdom
| | | | - Pavel Matousek
- Central Laser Facility, Research Complex at Harwell, STFC Rutherford Appleton Laboratory, UK Research and Innovation, Harwell Campus, OX11 0QX, United Kingdom
| | - Gianluca Valentini
- Dipartimento di Fisica, Politecnico di Milano, Milano, Italy
- Consiglio Nazionale delle Ricerche, Istituto di Fotonica e Nanotecnologie, Milano, Italy
| | - Antonio Pifferi
- Dipartimento di Fisica, Politecnico di Milano, Milano, Italy
- Consiglio Nazionale delle Ricerche, Istituto di Fotonica e Nanotecnologie, Milano, Italy
| |
Collapse
|
32
|
Shokoufi M, Haeri Z, Lim ZY, Ramaseshan R, Golnaraghi F. Translation of a portable diffuse optical breast scanner probe for clinical application: a preliminary study. Biomed Phys Eng Express 2020; 6:015037. [PMID: 33438625 DOI: 10.1088/2057-1976/ab6e19] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Most breast cancer lesions absorb higher levels of near-infrared (NIR) radiation compared to healthy breast tissue due to its increased vascularity. Oxy-hemoglobin (HbO2) and deoxy-hemoglobin (Hb) primarily found in cancerous vascular lesions, absorbs higher levels of radiation in the 650 nm to 850 nm wavelength range than the surrounding fatty tissue and water in the human breast. NIR diffuse optical spectroscopy (DOS) provides real-time functional and compositional information based on the optical properties of biological tissues, which cannot be accomplished by other portable breast imaging modalities. Here we present the first set of clinical trials using a non-invasive, hand-held diffuse optical breast scanner (DOB-Scan probe3) to capture in vivo cross-sectional images of the breast. The scanner uses four NIR illuminating sources with different wavelengths, 690 nm, 750 nm, 800 nm, and 850 nm, to determine the concentrations of the four main constituents of breast tissue, oxy-hemoglobin (HbO2), deoxy-hemoglobin (Hb), water (H2O), and fat. In this paper, we briefly explain the hardware design and image reconstruction algorithm of the DOB-Scan probe, the data collection process, and the imaging results of four different participants, selected from twenty, all who are diagnosed with breast cancer. For each patient, images were scanned from two locations, the first over the cancerous lesion and the second over the same region on the contralateral healthy breast, as a means of establishing controls for comparison. During each scan, four cross-sectional images of the breast, corresponding to four different NIR wavelengths, are reconstructed and displayed on a user interface for reference. Clinical results confirm that the absorption coefficients of cancerous lesions are significantly higher than the normal surrounding tissue. We propose to deploy the probe to effectively identify cancerous breast tissue at an early stage in a primary care setting, which could increase the efficiency of screening programs.
Collapse
Affiliation(s)
- Majid Shokoufi
- School of Mechatronic Systems Engineering, Simon Fraser University, 250-13450 102 Avenue, Surrey, BC, V3T 0A3, Canada
| | | | | | | | | |
Collapse
|
33
|
Liu Y, Gou H, Huang X, Zhang G, Xi K, Jia X. Rational synthesis of highly efficient ultra-narrow red-emitting carbon quantum dots for NIR-II two-photon bioimaging. NANOSCALE 2020; 12:1589-1601. [PMID: 31859306 DOI: 10.1039/c9nr09524a] [Citation(s) in RCA: 30] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
Abstract
Despite the growing research interest in highly bio-compatible carbon quantum dots (CQDs) for bioimaging, the synthesis of red-emitting CQDs with high photoluminescence efficiency and a sharp emission spectrum remains a formidable challenge in this field. Herein, we established a rational strategy for the synthesis of highly efficient ultra-narrow red-emitting CQDs by adopting a conjugated aromatic amine precursor (tris(4-aminophenyl)amine, TAPA) and introducing oxidative radical reagents. The resultant CQDs, T-CQDs featured red PL (615 ± 2 nm) with a high photoluminescence quantum yield (84 ± 5%) and a narrow emission linewidth (FWHM = 27 ± 1 nm), which together represented one of the highest levels in the field of CQDs so far. The T-CQDs were then further analyzed from the spectral and structural aspects, and the repeatability and universality of this strategy have also been discussed. Finally, the T-CQDs were successfully applied for both one-photon imaging and two-photon imaging with various bio-samples, both in vitro and in vivo.
Collapse
Affiliation(s)
- Yanfeng Liu
- School of Chemistry & Chemical Engineering, Nanjing University, Qixia District, Xianlin Road No. 163, Nanjing, 210023, P. R. China.
| | | | | | | | | | | |
Collapse
|
34
|
Broadband Time Domain Diffuse Optical Reflectance Spectroscopy: A Review of Systems, Methods, and Applications. APPLIED SCIENCES-BASEL 2019. [DOI: 10.3390/app9245465] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
This review presents recent developments and a wide overview of broadband time domain diffuse optical spectroscopy (TD-DOS). Various topics including physics of photon migration, advanced instrumentation, methods of analysis, applications covering multiple domains (tissue chromophore, in vivo studies, food, wood, pharmaceutical industry) are elaborated. The key role of standardization and recent studies in that direction are discussed. Towards the end, a brief outlook is presented on the current status and future trends in broadband TD-DOS.
Collapse
|
35
|
Sousa AS, Silva JF, Pavesi VCS, Carvalho NA, Ribeiro-Júnior O, Varellis MLZ, Prates RA, Bussadori SK, Gonçalves MLL, Horliana ACRT, Deana AM. Photobiomodulation and salivary glands: a systematic review. Lasers Med Sci 2019; 35:777-788. [DOI: 10.1007/s10103-019-02914-1] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2019] [Accepted: 10/30/2019] [Indexed: 12/14/2022]
|
36
|
Uzair U, Benza D, Behrend CJ, Anker JN. Noninvasively Imaging pH at the Surface of Implanted Orthopedic Devices with X-ray Excited Luminescence Chemical Imaging. ACS Sens 2019; 4:2367-2374. [PMID: 31487166 DOI: 10.1021/acssensors.9b00962] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Abstract
Implanted medical device-associated infections are a leading cause of fixation failure, and early diagnosis is the key to successful treatment. During infection, acidosis near the implant plays a role in antibiotic resistance and low pH is a potential infection indicator. Herein, we describe a pH sensor which attaches to the implants to noninvasively image local pH with high spatial resolution. The sensor has two layers: a scintillator layer which emits 620 and 700 nm light upon X-ray irradiation and a pH indicator layer containing bromocresol green dye that absorbs 620 nm luminescence in neutral/basic pH and passes 700 nm light at all pHs. We also developed a dedicated imaging system capable of scanning relatively large specimens through thick tissues. A focused X-ray beam irradiates one spot on the sensor, and the 620 to 700 nm peak ratio is measured to determine the local pH; images are acquired by scanning the X-ray beam across the surface and measuring the pH point-by-point. The sensor was covered with varying thickness slices of chicken breast tissue (0-19 mm) to evaluate how the tissue affects the peak intensity and ratio. Thick tissues attenuated both 620 and 700 nm light, with more attenuation at 620 nm than 700 nm. Although this spectral distortion shifted the pH calibration curve, the effect could be corrected for using a scintillator film region with no pH indicator layer as a spectral reference. The sensor was attached to an orthopedic plate affixed to a human cadaveric tibia and imaged through tissue. This approach provides both high spatial resolution from focused X-ray excitation and surface chemical specificity from the indicator dye, providing a tool for imaging local pH through tissue.
Collapse
|
37
|
Parkinson’s disease and light: The bright and the Dark sides. Brain Res Bull 2019; 150:290-296. [DOI: 10.1016/j.brainresbull.2019.06.013] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2019] [Revised: 06/11/2019] [Accepted: 06/14/2019] [Indexed: 01/06/2023]
|
38
|
Wheelock MD, Culver JP, Eggebrecht AT. High-density diffuse optical tomography for imaging human brain function. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2019; 90:051101. [PMID: 31153254 PMCID: PMC6533110 DOI: 10.1063/1.5086809] [Citation(s) in RCA: 64] [Impact Index Per Article: 12.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/23/2018] [Accepted: 04/14/2019] [Indexed: 05/08/2023]
Abstract
This review describes the unique opportunities and challenges for noninvasive optical mapping of human brain function. Diffuse optical methods offer safe, portable, and radiation free alternatives to traditional technologies like positron emission tomography or functional magnetic resonance imaging (fMRI). Recent developments in high-density diffuse optical tomography (HD-DOT) have demonstrated capabilities for mapping human cortical brain function over an extended field of view with image quality approaching that of fMRI. In this review, we cover fundamental principles of the diffusion of near infrared light in biological tissue. We discuss the challenges involved in the HD-DOT system design and implementation that must be overcome to acquire the signal-to-noise necessary to measure and locate brain function at the depth of the cortex. We discuss strategies for validation of the sensitivity, specificity, and reliability of HD-DOT acquired maps of cortical brain function. We then provide a brief overview of some clinical applications of HD-DOT. Though diffuse optical measurements of neurophysiology have existed for several decades, tremendous opportunity remains to advance optical imaging of brain function to address a crucial niche in basic and clinical neuroscience: that of bedside and minimally constrained high fidelity imaging of brain function.
Collapse
Affiliation(s)
- Muriah D. Wheelock
- Mallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis, Missouri 63110, USA
| | | | - Adam T. Eggebrecht
- Mallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis, Missouri 63110, USA
| |
Collapse
|
39
|
|
40
|
Althobaiti M, Vavadi H, Zhu Q. An Automated Preprocessing Method for Diffuse Optical Tomography to Improve Breast Cancer Diagnosis. Technol Cancer Res Treat 2019; 17:1533033818802791. [PMID: 30278830 PMCID: PMC6170968 DOI: 10.1177/1533033818802791] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023] Open
Abstract
The ultrasound-guided diffuse optical tomography is a noninvasive imaging technique for breast cancer diagnosis and treatment monitoring. The technique uses a handheld probe capable of providing measurements of multiple wavelengths in a few seconds. These measurements are used to estimate optical absorptions of lesions and calculate the total hemoglobin concentration. Any measurement errors caused by low signal to noise ratio data and/or movements during data acquisition would reduce the accuracy of reconstructed total hemoglobin concentration. In this article, we introduce an automated preprocessing method that combines data collected from multiple sets of lesion measurements of 4 optical wavelengths to detect and correct outliers in the perturbation. Two new measures of correlation between each pair of wavelength measurements and a wavelength consistency index of all reconstructed absorption maps are introduced. For phantom and patients' data without evidence of measurement errors, the correlation coefficient between each pair of wavelength measurements was above 0.6. However, for patients with measurement errors, the correlation coefficient was much lower. After applying the correction method to 18 patients' data with measurement errors, the correlation has improved and the wavelength consistency index is in the same range as the cases without wavelength-dependent measurement errors. The results show an improvement in classification of malignant and benign lesions.
Collapse
Affiliation(s)
- Murad Althobaiti
- 1 Biomedical Engineering Department, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Hamed Vavadi
- 2 Biomedical Engineering Department, University of Connecticut, Mansfield, CT, USA
| | - Quing Zhu
- 3 Biomedical Engineering Department, Washington University in St Louis, St Louis, MO, USA
| |
Collapse
|
41
|
Golovynskyi S, Golovynska I, Stepanova LI, Datsenko OI, Liu L, Qu J, Ohulchanskyy TY. Optical windows for head tissues in near-infrared and short-wave infrared regions: Approaching transcranial light applications. JOURNAL OF BIOPHOTONICS 2018; 11:e201800141. [PMID: 30098115 DOI: 10.1002/jbio.201800141] [Citation(s) in RCA: 78] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/18/2018] [Accepted: 08/09/2018] [Indexed: 05/02/2023]
Abstract
Optical properties of the rat head tissues (brain cortex, cranial bone and scalp skin) are assessed, aiming at transcranial light applications such as optical imaging and phototherapy. The spectral measurements are carried out over the wide spectral range of 350 to 2800 nm, involving visible, near-infrared (NIR) and short-wave infrared (SWIR) regions. Four tissue transparency windows are considered: ~700 to 1000 nm (NIR-I), ~1000 to 1350 nm (NIR-II), ~1550 to 1870 nm (NIR-III or SWIR) and ~2100 to 2300 nm (SWIR-II). The values of attenuation coefficient and total attenuation length are determined for all windows and tissue types. The spectra indicate transmittance peaks in NIR, NIR-II and SWIR-II, with maximum tissue permeability for SWIR light. The use of SWIR-II window for the transcranial light applications is substantiated. Furthermore, absorbance of the head tissues is investigated in details, by defining and describing the characteristic absorption peaks in NIR-SWIR.
Collapse
Affiliation(s)
- Sergii Golovynskyi
- Key Laboratory of Optoelectronic Devices and Systems of Ministry of Education and Guangdong Province, College of Optoelectronic Engineering, Shenzhen University, Shenzhen, China
| | - Iuliia Golovynska
- Key Laboratory of Optoelectronic Devices and Systems of Ministry of Education and Guangdong Province, College of Optoelectronic Engineering, Shenzhen University, Shenzhen, China
| | - Ludmila I Stepanova
- Institute of Biology and Medicine, Taras Shevchenko National University of Kyiv, Kyiv, Ukraine
| | | | - Liwei Liu
- Key Laboratory of Optoelectronic Devices and Systems of Ministry of Education and Guangdong Province, College of Optoelectronic Engineering, Shenzhen University, Shenzhen, China
| | - Junle Qu
- Key Laboratory of Optoelectronic Devices and Systems of Ministry of Education and Guangdong Province, College of Optoelectronic Engineering, Shenzhen University, Shenzhen, China
| | - Tymish Y Ohulchanskyy
- Key Laboratory of Optoelectronic Devices and Systems of Ministry of Education and Guangdong Province, College of Optoelectronic Engineering, Shenzhen University, Shenzhen, China
| |
Collapse
|
42
|
Pelivanov I, Petrova E, Yoon SJ, Qian Z, Guye K, O'Donnell M. Molecular fingerprinting of nanoparticles in complex media with non-contact photoacoustics: beyond the light scattering limit. Sci Rep 2018; 8:14425. [PMID: 30258194 PMCID: PMC6158233 DOI: 10.1038/s41598-018-32580-2] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2018] [Accepted: 09/06/2018] [Indexed: 11/09/2022] Open
Abstract
Optical instruments can probe physical systems even to the level of individual molecules. In particular, every molecule, solution, and structure such as a living cell has a unique absorption spectrum representing a molecular fingerprint. This spectrum can help identify a particular molecule from others or quantify its concentration; however, scattering limits molecular fingerprinting within a complex compound and must be overcome. Here, we present a new, non-contact photoacoustic (PA)-based method that can almost completely remove the influence of background light scattering on absorption measurements in heterogeneous highly scattering solutions and, furthermore, separate the intrinsic absorption of nanoscale objects from their scattering. In particular, we measure pure absorption spectra for solutions of gold nanorods (GNRs) as an example of a plasmonic agent and show that these spectra differ from the extinction measured with conventional UV-VIS spectrophotometry. Finally, we show how the original GNR absorption changes when nanoparticles are internalized by cells.
Collapse
Affiliation(s)
- Ivan Pelivanov
- Department of Bioengineering, University of Washington, Seattle, WA, 98195, USA.
| | - Elena Petrova
- Department of Bioengineering, University of Washington, Seattle, WA, 98195, USA
| | - Soon Joon Yoon
- Department of Bioengineering, University of Washington, Seattle, WA, 98195, USA
| | - Zhaoxia Qian
- Department of Chemistry, University of Washington, Seattle, WA, 98195, USA
| | - Kathryn Guye
- Department of Chemistry, University of Washington, Seattle, WA, 98195, USA
| | - Matthew O'Donnell
- Department of Bioengineering, University of Washington, Seattle, WA, 98195, USA
| |
Collapse
|
43
|
Liu S, Zhang R, Zheng Z, Zheng Y. Electromagnetic⁻Acoustic Sensing for Biomedical Applications. SENSORS (BASEL, SWITZERLAND) 2018; 18:E3203. [PMID: 30248969 PMCID: PMC6210000 DOI: 10.3390/s18103203] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/31/2018] [Accepted: 09/20/2018] [Indexed: 12/29/2022]
Abstract
This paper reviews the theories and applications of electromagnetic⁻acoustic (EMA) techniques (covering light-induced photoacoustic, microwave-induced thermoacoustic, magnetic-modulated thermoacoustic, and X-ray-induced thermoacoustic) belonging to the more general area of electromagnetic (EM) hybrid techniques. The theories cover excitation of high-power EM field (laser, microwave, magnetic field, and X-ray) and subsequent acoustic wave generation. The applications of EMA methods include structural imaging, blood flowmetry, thermometry, dosimetry for radiation therapy, hemoglobin oxygen saturation (SO₂) sensing, fingerprint imaging and sensing, glucose sensing, pH sensing, etc. Several other EM-related acoustic methods, including magnetoacoustic, magnetomotive ultrasound, and magnetomotive photoacoustic are also described. It is believed that EMA has great potential in both pre-clinical research and medical practice.
Collapse
Affiliation(s)
- Siyu Liu
- School of Electrical and Electronic Engineering, Nanyang Technological University, Singapore 639798, Singapore.
| | - Ruochong Zhang
- School of Electrical and Electronic Engineering, Nanyang Technological University, Singapore 639798, Singapore.
| | - Zesheng Zheng
- School of Electrical and Electronic Engineering, Nanyang Technological University, Singapore 639798, Singapore.
| | - Yuanjin Zheng
- School of Electrical and Electronic Engineering, Nanyang Technological University, Singapore 639798, Singapore.
| |
Collapse
|
44
|
Comparison of light propagation in dental tissues and nano-filled resin-based composite. Clin Oral Investig 2018; 23:423-433. [DOI: 10.1007/s00784-018-2451-9] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2017] [Accepted: 04/16/2018] [Indexed: 11/27/2022]
|
45
|
Low-level laser therapy for xerostomia in primary Sjögren’s syndrome: a randomized trial. Clin Rheumatol 2017; 37:729-736. [DOI: 10.1007/s10067-017-3898-9] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2017] [Revised: 10/19/2017] [Accepted: 10/27/2017] [Indexed: 10/18/2022]
|
46
|
Walther A, Rippe L, Wang LV, Andersson-Engels S, Kröll S. Analysis of the potential for non-invasive imaging of oxygenation at heart depth, using ultrasound optical tomography (UOT) or photo-acoustic tomography (PAT). BIOMEDICAL OPTICS EXPRESS 2017; 8:4523-4536. [PMID: 29082082 PMCID: PMC5654797 DOI: 10.1364/boe.8.004523] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/10/2017] [Revised: 09/05/2017] [Accepted: 09/11/2017] [Indexed: 05/30/2023]
Abstract
Despite the important medical implications, it is currently an open task to find optical non-invasive techniques that can image deep organs in humans. Addressing this, photo-acoustic tomography (PAT) has received a great deal of attention in the past decade, owing to favorable properties like high contrast and high spatial resolution. However, even with optimal components PAT cannot penetrate beyond a few centimeters, which still presents an important limitation of the technique. Here, we calculate the absorption contrast levels for PAT and for ultrasound optical tomography (UOT) and compare them to their relevant noise sources as a function of imaging depth. The results indicate that a new development in optical filters, based on rare-earth-ion crystals, can push the UOT technique significantly ahead of PAT. Such filters allow the contrast-to-noise ratio for UOT to be up to three orders of magnitude better than for PAT at depths of a few cm into the tissue. It also translates into a significant increase of the image depth of UOT compared to PAT, enabling deep organs to be imaged in humans in real time. Furthermore, such spectral holeburning filters are not sensitive to speckle decorrelation from the tissue and can operate at nearly any angle of incident light, allowing good light collection. We theoretically demonstrate the improved performance in the medically important case of non-invasive optical imaging of the oxygenation level of the frontal part of the human myocardial tissue. Our results indicate that further studies on UOT are of interest and that the technique may have large impact on future directions of biomedical optics.
Collapse
Affiliation(s)
| | - Lars Rippe
- Department of Physics, Lund University, 221 00 Lund,
Sweden
| | - Lihong V. Wang
- California Institute of Technology, 1200 E California Blvd., MC 138-78, Pasadena CA 91125,
USA
| | - Stefan Andersson-Engels
- Tyndall National Institute, Lee Maltings, Dyke Parade, Cork, T12 R5CP,
Ireland
- Department of Physics, University College Cork, Cork,
Ireland
| | - Stefan Kröll
- Department of Physics, Lund University, 221 00 Lund,
Sweden
| |
Collapse
|
47
|
Reisman MD, Markow ZE, Bauer AQ, Culver JP. Structured illumination diffuse optical tomography for noninvasive functional neuroimaging in mice. NEUROPHOTONICS 2017; 4:021102. [PMID: 28439519 PMCID: PMC5391480 DOI: 10.1117/1.nph.4.2.021102] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/10/2016] [Accepted: 02/01/2017] [Indexed: 05/15/2023]
Abstract
Optical intrinsic signal (OIS) imaging has been a powerful tool for capturing functional brain hemodynamics in rodents. Recent wide field-of-view implementations of OIS have provided efficient maps of functional connectivity from spontaneous brain activity in mice. However, OIS requires scalp retraction and is limited to superficial cortical tissues. Diffuse optical tomography (DOT) techniques provide noninvasive imaging, but previous DOT systems for rodent neuroimaging have been limited either by sparse spatial sampling or by slow speed. Here, we develop a DOT system with asymmetric source-detector sampling that combines the high-density spatial sampling (0.4 mm) detection of a scientific complementary metal-oxide-semiconductor camera with the rapid (2 Hz) imaging of a few ([Formula: see text]) structured illumination (SI) patterns. Analysis techniques are developed to take advantage of the system's flexibility and optimize trade-offs among spatial sampling, imaging speed, and signal-to-noise ratio. An effective source-detector separation for the SI patterns was developed and compared with light intensity for a quantitative assessment of data quality. The light fall-off versus effective distance was also used for in situ empirical optimization of our light model. We demonstrated the feasibility of this technique by noninvasively mapping the functional response in the somatosensory cortex of the mouse following electrical stimulation of the forepaw.
Collapse
Affiliation(s)
- Matthew D. Reisman
- Washington University in St. Louis, Department of Physics, St. Louis, Missouri, United States
| | - Zachary E. Markow
- Washington University in St. Louis, Department of Biomedical Engineering, St. Louis, Missouri, United States
| | - Adam Q. Bauer
- Washington University School of Medicine, Department of Radiology, St. Louis, Missouri, United States
| | - Joseph P. Culver
- Washington University in St. Louis, Department of Physics, St. Louis, Missouri, United States
- Washington University in St. Louis, Department of Biomedical Engineering, St. Louis, Missouri, United States
- Washington University School of Medicine, Department of Radiology, St. Louis, Missouri, United States
- Address all correspondence to: Joseph P. Culver, E-mail:
| |
Collapse
|
48
|
Horiuchi H, Sakai A, Akiyama S, Ikeda R, Ito S, Furuya M, Gomibuchi Y, Ichikawa M, Yoshihara T, Tobita S, Okutsu T. Extension of π-system of silylated porphyrin derivative for photodynamic therapy. J Photochem Photobiol A Chem 2017. [DOI: 10.1016/j.jphotochem.2017.02.015] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
49
|
Romeo S, Vitale F, Viaggi C, di Marco S, Aloisi G, Fasciani I, Pardini C, Pietrantoni I, Di Paolo M, Riccitelli S, Maccarone R, Mattei C, Capannolo M, Rossi M, Capozzo A, Corsini GU, Scarnati E, Lozzi L, Vaglini F, Maggio R. Fluorescent light induces neurodegeneration in the rodent nigrostriatal system but near infrared LED light does not. Brain Res 2017; 1662:87-101. [PMID: 28263713 DOI: 10.1016/j.brainres.2017.02.026] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2016] [Revised: 02/22/2017] [Accepted: 02/25/2017] [Indexed: 11/29/2022]
Abstract
We investigated the effects of continuous artificial light exposure on the mouse substantia nigra (SN). A three month exposure of C57Bl/6J mice to white fluorescent light induced a 30% reduction in dopamine (DA) neurons in SN compared to controls, accompanied by a decrease of DA and its metabolites in the striatum. After six months of exposure, neurodegeneration progressed slightly, but the level of DA returned to the basal level, while the metabolites increased with respect to the control. Three month exposure to near infrared LED light (∼710nm) did not alter DA neurons in SN, nor did it decrease DA and its metabolites in the striatum. Furthermore mesencephalic cell viability, as tested by [3H]DA uptake, did not change. Finally, we observed that 710nm LED light, locally conveyed in the rat SN, could modulate the firing activity of extracellular-recorded DA neurons. These data suggest that light can be detrimental or beneficial to DA neurons in SN, depending on the source and wavelength.
Collapse
Affiliation(s)
- Stefania Romeo
- Department of Applied Clinical and Biotechnological Sciences, University of L'Aquila, 67100 L'Aquila, Italy.
| | - Flora Vitale
- Department of Applied Clinical and Biotechnological Sciences, University of L'Aquila, 67100 L'Aquila, Italy
| | - Cristina Viaggi
- Department of Translational Research and New Technology in Medicine and Surgery, University of Pisa, 56126 Pisa, Italy
| | - Stefano di Marco
- Department of Applied Clinical and Biotechnological Sciences, University of L'Aquila, 67100 L'Aquila, Italy
| | - Gabriella Aloisi
- Department of Applied Clinical and Biotechnological Sciences, University of L'Aquila, 67100 L'Aquila, Italy
| | - Irene Fasciani
- Department of Applied Clinical and Biotechnological Sciences, University of L'Aquila, 67100 L'Aquila, Italy
| | - Carla Pardini
- Department of Translational Research and New Technology in Medicine and Surgery, University of Pisa, 56126 Pisa, Italy
| | - Ilaria Pietrantoni
- Department of Applied Clinical and Biotechnological Sciences, University of L'Aquila, 67100 L'Aquila, Italy
| | - Mattia Di Paolo
- Department of Applied Clinical and Biotechnological Sciences, University of L'Aquila, 67100 L'Aquila, Italy
| | - Serena Riccitelli
- Department of Applied Clinical and Biotechnological Sciences, University of L'Aquila, 67100 L'Aquila, Italy
| | - Rita Maccarone
- Department of Applied Clinical and Biotechnological Sciences, University of L'Aquila, 67100 L'Aquila, Italy
| | - Claudia Mattei
- Department of Applied Clinical and Biotechnological Sciences, University of L'Aquila, 67100 L'Aquila, Italy
| | - Marta Capannolo
- Department of Applied Clinical and Biotechnological Sciences, University of L'Aquila, 67100 L'Aquila, Italy
| | - Mario Rossi
- Molecular Signaling Section, Laboratory of Bioorganic Chemistry, National Institute of Diabetes and Digestive and Kidney Diseases, Bethesda, MA 20892, United States
| | - Annamaria Capozzo
- Department of Applied Clinical and Biotechnological Sciences, University of L'Aquila, 67100 L'Aquila, Italy
| | - Giovanni U Corsini
- Department of Translational Research and New Technology in Medicine and Surgery, University of Pisa, 56126 Pisa, Italy
| | - Eugenio Scarnati
- Department of Applied Clinical and Biotechnological Sciences, University of L'Aquila, 67100 L'Aquila, Italy
| | - Luca Lozzi
- Department of Physical and Chemical Sciences, University of L'Aquila, 67100 L'Aquila, Italy
| | - Francesca Vaglini
- Department of Translational Research and New Technology in Medicine and Surgery, University of Pisa, 56126 Pisa, Italy
| | - Roberto Maggio
- Department of Applied Clinical and Biotechnological Sciences, University of L'Aquila, 67100 L'Aquila, Italy
| |
Collapse
|
50
|
Althobaiti M, Vavadi H, Zhu Q. Diffuse optical tomography reconstruction method using ultrasound images as prior for regularization matrix. JOURNAL OF BIOMEDICAL OPTICS 2017; 22:26002. [PMID: 28152129 PMCID: PMC5299136 DOI: 10.1117/1.jbo.22.2.026002] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/01/2016] [Accepted: 01/12/2017] [Indexed: 05/05/2023]
Abstract
Ultrasound-guided diffuse optical tomography (DOT) is a promising imaging technique that maps hemoglobin concentrations of breast lesions to assist ultrasound (US) for cancer diagnosis and treatment monitoring. The accurate recovery of breast lesion optical properties requires an effective image reconstruction method. We introduce a reconstruction approach in which US images are encoded as prior information for regularization of the inversion matrix. The framework of this approach is based on image reconstruction package “NIRFAST.” We compare this approach to the US-guided dual-zone mesh reconstruction method, which is based on Born approximation and conjugate gradient optimization developed in our laboratory. Results were evaluated using phantoms and clinical data. This method improves classification of malignant and benign lesions by increasing malignant to benign lesion absorption contrast. The results also show improvements in reconstructed lesion shapes and the spatial distribution of absorption maps.
Collapse
Affiliation(s)
- Murad Althobaiti
- University of Connecticut, Department of Biomedical Engineering, Storrs, Connecticut, United States
| | - Hamed Vavadi
- University of Connecticut, Department of Biomedical Engineering, Storrs, Connecticut, United States
| | - Quing Zhu
- Washington University in St. Louis, Department of Biomedical Engineering, Missouri, United States
- Address all correspondence to: Quing Zhu, E-mail:
| |
Collapse
|