1
|
Huang G, Lin L, Liu Q, Wu S, Chen J, Zhu R, You H, Sun C. Three-dimensional array of microbubbles sonoporation of cells in microfluidics. Front Bioeng Biotechnol 2024; 12:1353333. [PMID: 38419723 PMCID: PMC10899490 DOI: 10.3389/fbioe.2024.1353333] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2023] [Accepted: 01/29/2024] [Indexed: 03/02/2024] Open
Abstract
Sonoporation is a popular membrane disruption technique widely applicable in various fields, including cell therapy, drug delivery, and biomanufacturing. In recent years, there has been significant progress in achieving controlled, high-viability, and high-efficiency cell sonoporation in microfluidics. If the microchannels are too small, especially when scaled down to the cellular level, it still remains a challenge to overcome microchannel clogging, and low throughput. Here, we presented a microfluidic device capable of modulating membrane permeability through oscillating three-dimensional array of microbubbles. Simulations were performed to analyze the effective range of action of the oscillating microbubbles to obtain the optimal microchannel size. Utilizing a high-precision light curing 3D printer to fabricate uniformly sized microstructures in a one-step on both the side walls and the top surface for the generation of microbubbles. These microbubbles oscillated with nearly identical amplitudes and frequencies, ensuring efficient and stable sonoporation within the system. Cells were captured and trapped on the bubble surface by the acoustic streaming and secondary acoustic radiation forces induced by the oscillating microbubbles. At a driving voltage of 30 Vpp, the sonoporation efficiency of cells reached 93.9% ± 2.4%.
Collapse
Affiliation(s)
- Guangyong Huang
- School of Mechanical Engineering, Guangxi University, Nanning, China
- School of Mechanical and Automotive Engineering, Guangxi University of Science and Technology, Liuzhou, China
| | - Lin Lin
- School of Mechanical Engineering, Guangxi University, Nanning, China
| | - Quanhui Liu
- Animal Science and Technology College, Guangxi University, Nanning, China
| | - Shixiong Wu
- School of Mechanical Engineering, Guangxi University, Nanning, China
| | - Jiapeng Chen
- School of Mechanical Engineering, Guangxi University, Nanning, China
| | - Rongxing Zhu
- School of Mechanical Engineering, Guangxi University, Nanning, China
| | - Hui You
- School of Mechanical Engineering, Guangxi University, Nanning, China
| | - Cuimin Sun
- School of Computer, Electronics and Information, Guangxi University, Nanning, China
| |
Collapse
|
2
|
Aliabouzar M, Abeid BA, Kripfgans OD, Fowlkes JB, Estrada JB, Fabiilli ML. Real-time spatiotemporal characterization of mechanics and sonoporation of acoustic droplet vaporization in acoustically responsive scaffolds. APPLIED PHYSICS LETTERS 2023; 123:114101. [PMID: 37705893 PMCID: PMC10497320 DOI: 10.1063/5.0159661] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/25/2023] [Accepted: 08/26/2023] [Indexed: 09/15/2023]
Abstract
Phase-shift droplets provide a flexible and dynamic platform for therapeutic and diagnostic applications of ultrasound. The spatiotemporal response of phase-shift droplets to focused ultrasound, via the mechanism termed acoustic droplet vaporization (ADV), can generate a range of bioeffects. Although ADV has been used widely in theranostic applications, ADV-induced bioeffects are understudied. Here, we integrated ultra-high-speed microscopy, confocal microscopy, and focused ultrasound for real-time visualization of ADV-induced mechanics and sonoporation in fibrin-based, tissue-mimicking hydrogels. Three monodispersed phase-shift droplets-containing perfluoropentane (PFP), perfluorohexane (PFH), or perfluorooctane (PFO)-with an average radius of ∼6 μm were studied. Fibroblasts and tracer particles, co-encapsulated within the hydrogel, were used to quantify sonoporation and mechanics resulting from ADV, respectively. The maximum radial expansion, expansion velocity, induced strain, and displacement of tracer particles were significantly higher in fibrin gels containing PFP droplets compared to PFH or PFO. Additionally, cell membrane permeabilization significantly depended on the distance between the droplet and cell (d), decreasing rapidly with increasing d. Significant membrane permeabilization occurred when d was smaller than the maximum radius of expansion. Both ultra-high-speed and confocal images indicate a hyper-local region of influence by an ADV bubble, which correlated inversely with the bulk boiling point of the phase-shift droplets. The findings provide insight into developing optimal approaches for therapeutic applications of ADV.
Collapse
Affiliation(s)
| | - Bachir A. Abeid
- Department of Mechanical Engineering, University of Michigan, Ann Arbor, Michigan 48109, USA
| | | | | | - Jonathan B. Estrada
- Department of Mechanical Engineering, University of Michigan, Ann Arbor, Michigan 48109, USA
| | | |
Collapse
|
3
|
Pandur Ž, Zevnik J, Podbevšek D, Stojković B, Stopar D, Dular M. Water treatment by cavitation: Understanding it at a single bubble - bacterial cell level. WATER RESEARCH 2023; 236:119956. [PMID: 37087917 DOI: 10.1016/j.watres.2023.119956] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/27/2022] [Revised: 04/06/2023] [Accepted: 04/07/2023] [Indexed: 05/03/2023]
Abstract
Cavitation is a potentially useful phenomenon accompanied by extreme conditions, which is one of the reasons for its increased use in a variety of applications, such as surface cleaning, enhanced chemistry, and water treatment. Yet, we are still not able to answer many fundamental questions related to efficacy and effectiveness of cavitation treatment, such as: "Can single bubbles destroy contaminants?" and "What precisely is the mechanism behind bubble's cleaning power?". For these reasons, the present paper addresses cavitation as a tool for eradication and removal of wall-bound bacteria at a fundamental level of a single microbubble and a bacterial cell. We present a method to study bubble-bacteria interaction on a nano- to microscale resolution in both space and time. The method allows for accurate and fast positioning of a single microbubble above the individual wall-bound bacterial cell with optical tweezers and triggering of a violent microscale cavitation event, which either results in mechanical removal or destruction of the bacterial cell. Results on E. coli bacteria show that only cells in the immediate vicinity of the microbubble are affected, and that a very high likelihood of cell detachment and cell death exists for cells located directly under the center of a bubble. Further details behind near-wall microbubble dynamics are revealed by numerical simulations, which demonstrate that a water jet resulting from a near-wall bubble implosion is the primary mechanism of wall-bound cell damage. The results suggest that peak hydrodynamic forces as high as 0.8 μN and 1.2 μN are required to achieve consistent E. coli bacterial cell detachment or death with high frequency mechanical perturbations on a nano- to microsecond time scale. Understanding of the cavitation phenomenon at a fundamental level of a single bubble will enable further optimization of novel water treatment and surface cleaning technologies to provide more efficient and chemical-free processes.
Collapse
Affiliation(s)
- Žiga Pandur
- Faculty of Mechanical Engineering, University of Ljubljana, Askerceva 6, 1000 Ljubljana, Slovenia; Biotechnical Faculty, University of Ljubljana, Jamnikarjeva 101, 1000 Ljubljana, Slovenia
| | - Jure Zevnik
- Faculty of Mechanical Engineering, University of Ljubljana, Askerceva 6, 1000 Ljubljana, Slovenia
| | - Darjan Podbevšek
- Faculty of Mechanical Engineering, University of Ljubljana, Askerceva 6, 1000 Ljubljana, Slovenia; Advanced Science Research Center at The Graduate Center of the City University of New York, 85 Saint Nicholas Terrace, New York, USA
| | - Biljana Stojković
- Faculty of Mechanical Engineering, University of Ljubljana, Askerceva 6, 1000 Ljubljana, Slovenia
| | - David Stopar
- Biotechnical Faculty, University of Ljubljana, Jamnikarjeva 101, 1000 Ljubljana, Slovenia
| | - Matevž Dular
- Faculty of Mechanical Engineering, University of Ljubljana, Askerceva 6, 1000 Ljubljana, Slovenia.
| |
Collapse
|
4
|
Namli I, Karavelioglu Z, Sarraf SS, Aghdam AS, Varol R, Yilmaz A, Sahin SB, Ozogul B, Bozkaya DN, Acar HF, Uvet H, Çetinel S, Kutlu Ö, Ghorbani M, Koşar A. On the application of hydrodynamic cavitation on a chip in cellular injury and drug delivery. LAB ON A CHIP 2023; 23:2640-2653. [PMID: 37183761 DOI: 10.1039/d3lc00177f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/16/2023]
Abstract
Hydrodynamic cavitation (HC) is a phase change phenomenon, where energy release in a fluid occurs upon the collapse of bubbles, which form due to the low local pressures. During recent years, due to advances in lab-on-a-chip technologies, HC-on-a-chip (HCOC) and its potential applications have attracted considerable interest. Microfluidic devices enable the performance of controlled experiments by enabling spatial control over the cavitation process and by precisely monitoring its evolution. In this study, we propose the adjunctive use of HC to induce distinct zones of cellular injury and enhance the anticancer efficacy of Doxorubicin (DOX). HC caused different regions (lysis, necrosis, permeabilization, and unaffected regions) upon exposure of different cancer and normal cells to HC. Moreover, HC was also applied to the confluent cell monolayer following the DOX treatment. Here, it was shown that the combination of DOX and HC exhibited a more pronounced anticancer activity on cancer cells than DOX alone. The effect of HC on cell permeabilization was also proven by using carbon dots (CDs). Finally, the cell stiffness parameter, which was associated with cell proliferation, migration and metastasis, was investigated with the use of cancer cells and normal cells under HC exposure. The HCOC offers the advantage of creating well-defined zones of bio-responses upon HC exposure simultaneously within minutes, achieving cell lysis and molecular delivery through permeabilization by providing spatial control. In conclusion, micro scale hydrodynamic cavitation proposes a promising alternative to be used to increase the therapeutic efficacy of anticancer drugs.
Collapse
Affiliation(s)
- Ilayda Namli
- Faculty of Engineering and Natural Sciences, Sabanci University, 34956 Tuzla, Istanbul, Turkey.
- Sabanci University Nanotechnology Research and Application Center, 34956 Tuzla, Istanbul, Turkey
| | - Zeynep Karavelioglu
- Department of Bioengineering, Yildiz Technical University, 34349, Besiktas, Istanbul, Turkey
| | - Seyedali Seyedmirzaei Sarraf
- Faculty of Engineering and Natural Sciences, Sabanci University, 34956 Tuzla, Istanbul, Turkey.
- Sabanci University Nanotechnology Research and Application Center, 34956 Tuzla, Istanbul, Turkey
| | - Araz Sheibani Aghdam
- Faculty of Engineering and Natural Sciences, Sabanci University, 34956 Tuzla, Istanbul, Turkey.
- Sabanci University Nanotechnology Research and Application Center, 34956 Tuzla, Istanbul, Turkey
| | - Rahmetullah Varol
- Department of Mechatronics Engineering, Yildiz Technical University, 34349, Besiktas, Istanbul, Turkey
| | - Abdurrahim Yilmaz
- Department of Mechatronics Engineering, Yildiz Technical University, 34349, Besiktas, Istanbul, Turkey
| | - Sevilay Burcu Sahin
- Faculty of Engineering and Natural Sciences, Sabanci University, 34956 Tuzla, Istanbul, Turkey.
- Sabanci University Nanotechnology Research and Application Center, 34956 Tuzla, Istanbul, Turkey
| | - Beyzanur Ozogul
- Faculty of Engineering and Natural Sciences, Sabanci University, 34956 Tuzla, Istanbul, Turkey.
- Sabanci University Nanotechnology Research and Application Center, 34956 Tuzla, Istanbul, Turkey
| | - Dila Naz Bozkaya
- Department of Biology, Istanbul University, Beyazit, 34452, Istanbul, Turkey
| | - Havva Funda Acar
- Department of Chemistry, Koç University, Sariyer, 34450, Istanbul, Turkey
| | - Huseyin Uvet
- Department of Mechatronics Engineering, Yildiz Technical University, 34349, Besiktas, Istanbul, Turkey
| | - Sibel Çetinel
- Sabanci University Nanotechnology Research and Application Center, 34956 Tuzla, Istanbul, Turkey
- Center of Excellence for Functional Surfaces and Interfaces for Nano-Diagnostics (EFSUN), Sabanci University, Orhanli, 34956, Tuzla, Istanbul, Turkey
| | - Özlem Kutlu
- Sabanci University Nanotechnology Research and Application Center, 34956 Tuzla, Istanbul, Turkey
- Center of Excellence for Functional Surfaces and Interfaces for Nano-Diagnostics (EFSUN), Sabanci University, Orhanli, 34956, Tuzla, Istanbul, Turkey
| | - Morteza Ghorbani
- Faculty of Engineering and Natural Sciences, Sabanci University, 34956 Tuzla, Istanbul, Turkey.
- Sabanci University Nanotechnology Research and Application Center, 34956 Tuzla, Istanbul, Turkey
- Center of Excellence for Functional Surfaces and Interfaces for Nano-Diagnostics (EFSUN), Sabanci University, Orhanli, 34956, Tuzla, Istanbul, Turkey
| | - Ali Koşar
- Faculty of Engineering and Natural Sciences, Sabanci University, 34956 Tuzla, Istanbul, Turkey.
- Sabanci University Nanotechnology Research and Application Center, 34956 Tuzla, Istanbul, Turkey
- Center of Excellence for Functional Surfaces and Interfaces for Nano-Diagnostics (EFSUN), Sabanci University, Orhanli, 34956, Tuzla, Istanbul, Turkey
| |
Collapse
|
5
|
Kaykanat SI, Uguz AK. The role of acoustofluidics and microbubble dynamics for therapeutic applications and drug delivery. BIOMICROFLUIDICS 2023; 17:021502. [PMID: 37153864 PMCID: PMC10162024 DOI: 10.1063/5.0130769] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/14/2022] [Accepted: 03/18/2023] [Indexed: 05/10/2023]
Abstract
Targeted drug delivery is proposed to reduce the toxic effects of conventional therapeutic methods. For that purpose, nanoparticles are loaded with drugs called nanocarriers and directed toward a specific site. However, biological barriers challenge the nanocarriers to convey the drug to the target site effectively. Different targeting strategies and nanoparticle designs are used to overcome these barriers. Ultrasound is a new, safe, and non-invasive drug targeting method, especially when combined with microbubbles. Microbubbles oscillate under the effect of the ultrasound, which increases the permeability of endothelium, hence, the drug uptake to the target site. Consequently, this new technique reduces the dose of the drug and avoids its side effects. This review aims to describe the biological barriers and the targeting types with the critical features of acoustically driven microbubbles focusing on biomedical applications. The theoretical part covers the historical developments in microbubble models for different conditions: microbubbles in an incompressible and compressible medium and bubbles encapsulated by a shell. The current state and the possible future directions are discussed.
Collapse
Affiliation(s)
- S. I. Kaykanat
- Department of Chemical Engineering, Boğaziçi University, 34342 Bebek, Istanbul, Türkiye
| | | |
Collapse
|
6
|
Agrež V, Mur J, Petelin J, Petkovšek R. Near threshold nucleation and growth of cavitation bubbles generated with a picosecond laser. ULTRASONICS SONOCHEMISTRY 2023; 92:106243. [PMID: 36459905 PMCID: PMC9712668 DOI: 10.1016/j.ultsonch.2022.106243] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/27/2022] [Revised: 11/11/2022] [Accepted: 11/25/2022] [Indexed: 06/06/2023]
Abstract
The nucleation and growth of cavitation bubbles few micrometers in size in water generated by a 60 ps 515 nm fiber laser is observed and visualized near nucleation threshold. The study is performed by monitoring the plasma size, the cavitation bubble size and the emitted shock waves. The latter two aspects are supported by the Gilmore model using a Noble-Abel-stiffened-gas (NASG) equations of state. For the first time, two types of cavitation events are identified and visualized that exhibit a difference of more than two orders of magnitude in the excitation energy converted to mechanical effects with minimal change in excitation laser pulse energy. The result is localized cavitation and reduced mechanical stress on water-based media with potentially positive implications for laser treatments of biological tissue.
Collapse
Affiliation(s)
- Vid Agrež
- Faculty of Mechanical Engineering, University of Ljubljana, Ljubljana, Slovenia
| | - Jaka Mur
- Faculty of Mechanical Engineering, University of Ljubljana, Ljubljana, Slovenia
| | - Jaka Petelin
- Faculty of Mechanical Engineering, University of Ljubljana, Ljubljana, Slovenia
| | - Rok Petkovšek
- Faculty of Mechanical Engineering, University of Ljubljana, Ljubljana, Slovenia.
| |
Collapse
|
7
|
Baek JM, Jung WH, Yu ES, Ahn DJ, Ryu YS. In Vitro Membrane Platform for the Visualization of Water Impermeability across the Liquid-Ordered Phase under Hypertonic Conditions. J Am Chem Soc 2022; 144:21887-21896. [PMID: 36367984 DOI: 10.1021/jacs.2c06626] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
Passive water penetration across the cell membrane by osmotic diffusion is essential for the homeostasis of cell volume, in addition to the protein-assisted active transportation of water. Since membrane components can regulate water permeability, controlling compositional variation during the volume regulatory process is a prerequisite for investigating the underlying mechanisms of water permeation and related membrane dynamics. However, the lack of a viable in vitro membrane platform in hypertonic solutions impedes advanced knowledge of cell volume regulation processes, especially cholesterol-enriched lipid domains called lipid rafts. By reconstituting the liquid-ordered (Lo) domain as a likeness of lipid rafts, we verified suppressed water permeation across the Lo domains, which had yet to be confirmed with experimental demonstrations despite a simulation approach. With the help of direct transfer of the Lo domains from vesicles to supported lipid membranes, the biological roles of lipid composition in suppressed water translocation were experimentally confirmed. Additionally, the improvement in membrane stability under hypertonic conditions was demonstrated based on molecular dynamics simulations.
Collapse
Affiliation(s)
- Ji Min Baek
- Brain Science Institute, Korea Institute of Science and Technology, Seoul 02792, Republic of Korea.,Department of Chemical and Biological Engineering, Korea University, Seoul 02841, Republic of Korea
| | - Woo Hyuk Jung
- Department of Chemical and Biological Engineering, Korea University, Seoul 02841, Republic of Korea
| | - Eui-Sang Yu
- Brain Science Institute, Korea Institute of Science and Technology, Seoul 02792, Republic of Korea
| | - Dong June Ahn
- Department of Chemical and Biological Engineering, Korea University, Seoul 02841, Republic of Korea.,KU-KIST Graduate School of Converging Science and Technology, Korea University, Seoul 02841, Republic of Korea
| | - Yong-Sang Ryu
- Brain Science Institute, Korea Institute of Science and Technology, Seoul 02792, Republic of Korea.,KU-KIST Graduate School of Converging Science and Technology, Korea University, Seoul 02841, Republic of Korea
| |
Collapse
|
8
|
Acoustic bubble array-induced jet flow for cleaning particulate contaminants on semiconductor wafers. KOREAN J CHEM ENG 2022. [DOI: 10.1007/s11814-022-1214-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
|
9
|
Przystupski D, Ussowicz M. Landscape of Cellular Bioeffects Triggered by Ultrasound-Induced Sonoporation. Int J Mol Sci 2022; 23:ijms231911222. [PMID: 36232532 PMCID: PMC9569453 DOI: 10.3390/ijms231911222] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2022] [Revised: 09/16/2022] [Accepted: 09/20/2022] [Indexed: 11/18/2022] Open
Abstract
Sonoporation is the process of transient pore formation in the cell membrane triggered by ultrasound (US). Numerous studies have provided us with firm evidence that sonoporation may assist cancer treatment through effective drug and gene delivery. However, there is a massive gap in the body of literature on the issue of understanding the complexity of biophysical and biochemical sonoporation-induced cellular effects. This study provides a detailed explanation of the US-triggered bioeffects, in particular, cell compartments and the internal environment of the cell, as well as the further consequences on cell reproduction and growth. Moreover, a detailed biophysical insight into US-provoked pore formation is presented. This study is expected to review the knowledge of cellular effects initiated by US-induced sonoporation and summarize the attempts at clinical implementation.
Collapse
|
10
|
van Wamel A, Mühlenpfordt M, Hansen R, Healey A, Villanueva FS, Kotopoulis S, Davies CDL, Chen X. Ultrafast Microscopy Imaging of Acoustic Cluster Therapy Bubbles: Activation and Oscillation. ULTRASOUND IN MEDICINE & BIOLOGY 2022; 48:1840-1857. [PMID: 35773079 DOI: 10.1016/j.ultrasmedbio.2022.05.009] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/08/2021] [Revised: 02/15/2022] [Accepted: 05/10/2022] [Indexed: 06/15/2023]
Abstract
Acoustic Cluster Therapy (ACT®) is a platform for improving drug delivery and has had promising pre-clinical results. A clinical trial is ongoing. ACT® is based on microclusters of microbubbles-microdroplets that, when sonicated, form a large ACT® bubble. The aim of this study was to obtain new knowledge on the dynamic formation and oscillations of ACT® bubbles by ultrafast optical imaging in a microchannel. The high-speed recordings revealed the microbubble-microdroplet fusion, and the gas in the microbubble acted as a vaporization seed for the microdroplet. Subsequently, the bubble grew by gas diffusion from the surrounding medium and became a large ACT® bubble with a diameter of 5-50 μm. A second ultrasound exposure at lower frequency caused the ACT® bubble to oscillate. The recorded oscillations were compared with simulations using the modified Rayleigh-Plesset equation. A term accounting for the physical boundary imposed by the microchannel wall was included. The recorded oscillation amplitudes were approximately 1-2 µm, hence similar to oscillations of smaller contrast agent microbubbles. These findings, together with our previously reported promising pre-clinical therapeutic results, suggest that these oscillations covering a large part of the vessel wall because of the large bubble volume can substantially improve therapeutic outcome.
Collapse
Affiliation(s)
- Annemieke van Wamel
- Department of Physics, Norwegian University of Science and Technology, Trondheim, Norway
| | - Melina Mühlenpfordt
- Department of Physics, Norwegian University of Science and Technology, Trondheim, Norway
| | - Rune Hansen
- Department of Health Research, SINTEF Digital, Trondheim, Norway; Department of Circulation and Medical Imaging, Norwegian University of Science and Technology, Trondheim, Norway
| | | | - Flordeliza S Villanueva
- Center for Ultrasound Molecular Imaging and Therapeutics, University of Pittsburgh, Pittsburgh, Pennsylvania, USA
| | - Spiros Kotopoulis
- Department of Physics, Norwegian University of Science and Technology, Trondheim, Norway; Department of Clinical Medicine, University of Bergen, Bergen, Norway
| | | | - Xucai Chen
- Center for Ultrasound Molecular Imaging and Therapeutics, University of Pittsburgh, Pittsburgh, Pennsylvania, USA
| |
Collapse
|
11
|
Seyedmirzaei Sarraf S, Rokhsar Talabazar F, Namli I, Maleki M, Sheibani Aghdam A, Gharib G, Grishenkov D, Ghorbani M, Koşar A. Fundamentals, biomedical applications and future potential of micro-scale cavitation-a review. LAB ON A CHIP 2022; 22:2237-2258. [PMID: 35531747 DOI: 10.1039/d2lc00169a] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Thanks to the developments in the area of microfluidics, the cavitation-on-a-chip concept enabled researchers to control and closely monitor the cavitation phenomenon in micro-scale. In contrast to conventional scale, where cavitation bubbles are hard to be steered and manipulated, lab-on-a-chip devices provide suitable platforms to conduct smart experiments and design reliable devices to carefully harness the collapse energy of cavitation bubbles in different bio-related and industrial applications. However, bubble behavior deviates to some extent when confined to micro-scale geometries in comparison to macro-scale. Therefore, fundamentals of micro-scale cavitation deserve in-depth investigations. In this review, first we discussed the physics and fundamentals of cavitation induced by tension-based as well as energy deposition-based methods within microfluidic devices and discussed the similarities and differences in micro and macro-scale cavitation. We then covered and discussed recent developments in bio-related applications of micro-scale cavitation chips. Lastly, current challenges and future research directions towards the implementation of micro-scale cavitation phenomenon to emerging applications are presented.
Collapse
Affiliation(s)
- Seyedali Seyedmirzaei Sarraf
- Faculty of Engineering and Natural Science, Sabanci University, 34956 Tuzla, Istanbul, Turkey.
- Sabanci University Nanotechnology Research and Application Center, 34956 Tuzla, Istanbul, Turkey
| | - Farzad Rokhsar Talabazar
- Faculty of Engineering and Natural Science, Sabanci University, 34956 Tuzla, Istanbul, Turkey.
- Sabanci University Nanotechnology Research and Application Center, 34956 Tuzla, Istanbul, Turkey
| | - Ilayda Namli
- Faculty of Engineering and Natural Science, Sabanci University, 34956 Tuzla, Istanbul, Turkey.
- Sabanci University Nanotechnology Research and Application Center, 34956 Tuzla, Istanbul, Turkey
| | - Mohammadamin Maleki
- Faculty of Engineering and Natural Science, Sabanci University, 34956 Tuzla, Istanbul, Turkey.
- Sabanci University Nanotechnology Research and Application Center, 34956 Tuzla, Istanbul, Turkey
| | - Araz Sheibani Aghdam
- Faculty of Engineering and Natural Science, Sabanci University, 34956 Tuzla, Istanbul, Turkey.
- Sabanci University Nanotechnology Research and Application Center, 34956 Tuzla, Istanbul, Turkey
| | - Ghazaleh Gharib
- Faculty of Engineering and Natural Science, Sabanci University, 34956 Tuzla, Istanbul, Turkey.
- Sabanci University Nanotechnology Research and Application Center, 34956 Tuzla, Istanbul, Turkey
- Center of Excellence for Functional Surfaces and Interfaces for Nano-Diagnostics (EFSUN), Sabanci University, Orhanli, 34956, Tuzla, Istanbul, Turkey
| | - Dmitry Grishenkov
- Department of Biomedical Engineering and Health Systems, KTH Royal Institute of Technology, SE-141 57 Stockholm, Sweden
| | - Morteza Ghorbani
- Faculty of Engineering and Natural Science, Sabanci University, 34956 Tuzla, Istanbul, Turkey.
- Sabanci University Nanotechnology Research and Application Center, 34956 Tuzla, Istanbul, Turkey
- Center of Excellence for Functional Surfaces and Interfaces for Nano-Diagnostics (EFSUN), Sabanci University, Orhanli, 34956, Tuzla, Istanbul, Turkey
| | - Ali Koşar
- Faculty of Engineering and Natural Science, Sabanci University, 34956 Tuzla, Istanbul, Turkey.
- Sabanci University Nanotechnology Research and Application Center, 34956 Tuzla, Istanbul, Turkey
- Center of Excellence for Functional Surfaces and Interfaces for Nano-Diagnostics (EFSUN), Sabanci University, Orhanli, 34956, Tuzla, Istanbul, Turkey
| |
Collapse
|
12
|
Zevnik J, Dular M. Cavitation bubble interaction with compliant structures on a microscale: A contribution to the understanding of bacterial cell lysis by cavitation treatment. ULTRASONICS SONOCHEMISTRY 2022; 87:106053. [PMID: 35690044 PMCID: PMC9190065 DOI: 10.1016/j.ultsonch.2022.106053] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/21/2022] [Revised: 05/17/2022] [Accepted: 05/30/2022] [Indexed: 05/09/2023]
Abstract
Numerous studies have already shown that the process of cavitation can be successfully used for water treatment and eradication of bacteria. However, most of the relevant studies are being conducted on a macro scale, so the understanding of the processes at a fundamental level remains poor. In attempt to further elucidate the process of cavitation-assisted water treatment on a scale of a single bubble, the present paper numerically addresses interaction between a collapsing microbubble and a nearby compliant structure, that mechanically and structurally resembles a bacterial cell. A fluid-structure interaction methodology is employed, where compressible multiphase flow is considered and the bacterial cell wall is modeled as a multi-layered shell structure. Simulations are performed for two selected model structures, each resembling the main structural features of Gram-negative and Gram-positive bacterial cell envelopes. The contribution of two independent dimensionless geometric parameters is investigated, namely the bubble-cell distance δ and their size ratio ς. Three characteristic modes of bubble collapse dynamics and four modes of spatiotemporal occurrence of peak local stresses in the bacterial cell membrane are identified throughout the parameter space considered. The former range from the development of a weak and thin jet away from the cell to spherical bubble collapses. The results show that local stresses arising from bubble-induced loads can exceed poration thresholds of cell membranes and that bacterial cell damage could be explained solely by mechanical effects in absence of thermal and chemical ones. Based on this, the damage potential of a single microbubble for bacteria eradication is estimated, showing a higher resistance of the Gram-positive model organism to the nearby bubble collapse. Microstreaming is identified as the primary mechanical mechanism of bacterial cell damage, which in certain cases may be enhanced by the occurrence of shock waves during bubble collapse. The results are also discussed in the scope of bacteria eradication by cavitation treatment on a macro scale, where processes of hydrodynamic and ultrasonic cavitation are being employed.
Collapse
Affiliation(s)
- Jure Zevnik
- University of Ljubljana, Faculty of Mechanical Engineering, Aškerčeva cesta 6, Ljubljana, Slovenia.
| | - Matevž Dular
- University of Ljubljana, Faculty of Mechanical Engineering, Aškerčeva cesta 6, Ljubljana, Slovenia
| |
Collapse
|
13
|
Pourabed A, Chakkumpulakkal Puthan Veettil T, Devendran C, Nair P, Wood BR, Alan T. A star shaped acoustofluidic mixer enhances rapid malaria diagnostics via cell lysis and whole blood homogenisation in 2 seconds. LAB ON A CHIP 2022; 22:1829-1840. [PMID: 35380576 DOI: 10.1039/d2lc00195k] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/11/2023]
Abstract
Malaria is a life-threatening disease caused by a parasite, which can be transmitted to humans through bites of infected female Anopheles mosquitoes. This disease plagues a significant population of the world, necessitating the need for better diagnostic platforms to enhance the detection sensitivity, whilst reducing processing times, sample volumes and cost. A critical step in achieving improved detection is the effective lysis of blood samples. Here, we propose the use of an acoustically actuated microfluidic mixer for enhanced blood cell lysis. Guided by numerical simulations, we experimentally demonstrate that the device is capable of lysing a 20× dilution of isolated red blood cells (RBCs) with an efficiency of ∼95% within 350 ms (0.1 mL). Further, experimental results show that the device can effectively lyse whole blood irrespective of its dilution factor. Compared to the conventional method of using water, this platform is capable of releasing a larger quantity of haemoglobin into plasma, increasing the efficiency without the need for lysis reagents. The lysis efficiency was validated with malaria infected whole blood samples, resulting in an improved sensitivity as compared to the unlysed infected samples. Partial least squares-regression (PLS-R) analysis exhibits cross-validated R2 values of 0.959 and 0.98 from unlysed and device lysed spectral datasets, respectively. Critically, as expected, the root mean square error of cross validation (RMSECV) value was significantly reduced in the acoustically lysed datasets (RMSECV of 0.97), indicating the improved quantification of parasitic infections compared to unlysed datasets (RMSECV of 1.48). High lysis efficiency and ultrafast processing of very small sample volumes makes the combined acoustofluidic/spectroscopic approach extremely attractive for point-of-care blood diagnosis, especially for detection of neonatal and congenital malaria in babies, for whom a heel prick is often the only option for blood collection.
Collapse
Affiliation(s)
- Amir Pourabed
- Department of Mechanical and Aerospace Engineering, Monash University, Melbourne, VIC, Australia.
| | | | - Citsabehsan Devendran
- Department of Mechanical and Aerospace Engineering, Monash University, Melbourne, VIC, Australia.
| | - Prasanna Nair
- Department of Mechanical and Aerospace Engineering, Monash University, Melbourne, VIC, Australia.
- Department of Biosciences & Bioengineering, Indian Institute of Technology Bombay, Mumbai 400076, India
| | - Bayden R Wood
- Monash Centre for Biospectroscopy, Department of Chemistry, Monash University, Melbourne, VIC, Australia.
| | - Tuncay Alan
- Department of Mechanical and Aerospace Engineering, Monash University, Melbourne, VIC, Australia.
| |
Collapse
|
14
|
Tu J, Yu ACH. Ultrasound-Mediated Drug Delivery: Sonoporation Mechanisms, Biophysics, and Critical Factors. BME FRONTIERS 2022; 2022:9807347. [PMID: 37850169 PMCID: PMC10521752 DOI: 10.34133/2022/9807347] [Citation(s) in RCA: 36] [Impact Index Per Article: 18.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2021] [Accepted: 12/31/2021] [Indexed: 10/19/2023] Open
Abstract
Sonoporation, or the use of ultrasound in the presence of cavitation nuclei to induce plasma membrane perforation, is well considered as an emerging physical approach to facilitate the delivery of drugs and genes to living cells. Nevertheless, this emerging drug delivery paradigm has not yet reached widespread clinical use, because the efficiency of sonoporation is often deemed to be mediocre due to the lack of detailed understanding of the pertinent scientific mechanisms. Here, we summarize the current observational evidence available on the notion of sonoporation, and we discuss the prevailing understanding of the physical and biological processes related to sonoporation. To facilitate systematic understanding, we also present how the extent of sonoporation is dependent on a multitude of factors related to acoustic excitation parameters (ultrasound frequency, pressure, cavitation dose, exposure time), microbubble parameters (size, concentration, bubble-to-cell distance, shell composition), and cellular properties (cell type, cell cycle, biochemical contents). By adopting a science-backed approach to the realization of sonoporation, ultrasound-mediated drug delivery can be more controllably achieved to viably enhance drug uptake into living cells with high sonoporation efficiency. This drug delivery approach, when coupled with concurrent advances in ultrasound imaging, has potential to become an effective therapeutic paradigm.
Collapse
Affiliation(s)
- Juan Tu
- Key Laboratory of Modern Acoustics (MOE), Department of Physics, Collaborative Innovation Center of Advanced Microstructure, Nanjing University, Nanjing, China
| | - Alfred C. H. Yu
- Schlegel Research Institute for Aging, University of Waterloo, Waterloo, ON, Canada
| |
Collapse
|
15
|
Liu X, Zhang W, Jing Y, Yi S, Farooq U, Shi J, Pang N, Rong N, Xu L. Non-Cavitation Targeted Microbubble-Mediated Single-Cell Sonoporation. MICROMACHINES 2022; 13:mi13010113. [PMID: 35056278 PMCID: PMC8780975 DOI: 10.3390/mi13010113] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/05/2021] [Revised: 01/05/2022] [Accepted: 01/07/2022] [Indexed: 02/04/2023]
Abstract
Sonoporation employs ultrasound accompanied by microbubble (MB) cavitation to induce the reversible disruption of cell membranes and has been exploited as a promising intracellular macromolecular delivery strategy. Due to the damage to cells resulting from strong cavitation, it is difficult to balance efficient delivery and high survival rates. In this paper, a traveling surface acoustic wave (TSAW) device, consisting of a TSAW chip and a polydimethylsiloxane (PDMS) channel, was designed to explore single-cell sonoporation using targeted microbubbles (TMBs) in a non-cavitation regime. A TSAW was applied to precisely manipulate the movement of the TMBs attached to MDA-MB-231 cells, leading to sonoporation at a single-cell level. The impact of input voltage and the number of TMBs on cell sonoporation was investigated. In addition, the physical mechanisms of bubble cavitation or the acoustic radiation force (ARF) for cell sonoporation were analyzed. The TMBs excited by an ARF directly propelled cell membrane deformation, leading to reversible perforation in the cell membrane. When two TMBs adhered to the cell surface and the input voltage was 350 mVpp, the cell sonoporation efficiency went up to 83%.
Collapse
Affiliation(s)
- Xiufang Liu
- College of Medicine and Biological Information Engineering, Northeastern University, 195 Innovation Road, Shenyang 110016, China; (X.L.); (N.P.)
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China; (Y.J.); (S.Y.); (U.F.); (J.S.)
| | - Wenjun Zhang
- Department of Mechanical and Electrical Engineering, Gannan University of Science and Technology, 156 Kejia Avenue, Ganzhou 341000, China;
| | - Yanshu Jing
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China; (Y.J.); (S.Y.); (U.F.); (J.S.)
- Department of Biomedical Engineering, School of Life Science and Technology, Xi’an Jiaotong University, Xi’an 710049, China
| | - Shasha Yi
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China; (Y.J.); (S.Y.); (U.F.); (J.S.)
| | - Umar Farooq
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China; (Y.J.); (S.Y.); (U.F.); (J.S.)
| | - Jingyao Shi
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China; (Y.J.); (S.Y.); (U.F.); (J.S.)
| | - Na Pang
- College of Medicine and Biological Information Engineering, Northeastern University, 195 Innovation Road, Shenyang 110016, China; (X.L.); (N.P.)
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China; (Y.J.); (S.Y.); (U.F.); (J.S.)
| | - Ning Rong
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China; (Y.J.); (S.Y.); (U.F.); (J.S.)
- Correspondence: (N.R.); (L.X.); Tel.: +86-024-83683200 (L.X.)
| | - Lisheng Xu
- College of Medicine and Biological Information Engineering, Northeastern University, 195 Innovation Road, Shenyang 110016, China; (X.L.); (N.P.)
- Neusoft Research of Intelligent Healthcare Technology, Co., Ltd., Shenyang 110167, China
- Correspondence: (N.R.); (L.X.); Tel.: +86-024-83683200 (L.X.)
| |
Collapse
|
16
|
Zevnik J, Dular M. Liposome destruction by a collapsing cavitation microbubble: A numerical study. ULTRASONICS SONOCHEMISTRY 2021; 78:105706. [PMID: 34411844 PMCID: PMC8379499 DOI: 10.1016/j.ultsonch.2021.105706] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/02/2021] [Revised: 07/16/2021] [Accepted: 07/30/2021] [Indexed: 05/07/2023]
Abstract
Hydrodynamic cavitation poses as a promising new method for wastewater treatment as it has been shown to be able to eradicate bacteria, inactivate viruses, and destroy other biological structures, such as liposomes. Although engineers are already commercializing devices that employ cavitation, we are still not able to answer the fundamental question: What exactly are the damaging mechanisms of hydrodynamic cavitation in various applications? In this light, the present paper numerically addresses the interaction between a single cavitation microbubble and a nearby lipid vesicle of a similar size. A coupled fluid-structure interaction model is employed, from which three critical modes of vesicle deformation are identified and temporally placed in relation to their corresponding driving mechanisms: (a) unilateral stretching at the waist of the liposome during the first bubble collapse and subsequent shock wave propagation, (b) local wrinkling at the tip until the bubble rebounds, and (c) bilateral stretching at the tip of the liposome during the phase of a second bubble contraction. Here, unilateral and bilateral stretching refer to the local in-plane extension of the bilayer in one and both principal directions, respectively. Results are discussed with respect to critical dimensionless distance for vesicle poration and rupture. Liposomes with initially equilibrated envelopes are not expected to be structurally compromised in cases with δ>1.0, when a nearby collapsing bubble is not in their direct contact. However, the critical dimensionless distance for the case of an envelope with pre-existing pores is identified at δ=1.9. Additionally, the influence of liposome-bubble size ratio is addressed, from which a higher potential of larger bubbles for causing stretching-induced liposome destruction can be identified.
Collapse
Affiliation(s)
- Jure Zevnik
- University of Ljubljana, Faculty of Mechanical Engineering, Aškerčeva cesta 6, Ljubljana, Slovenia.
| | - Matevž Dular
- University of Ljubljana, Faculty of Mechanical Engineering, Aškerčeva cesta 6, Ljubljana, Slovenia
| |
Collapse
|
17
|
Hur J, Chung AJ. Microfluidic and Nanofluidic Intracellular Delivery. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2021; 8:e2004595. [PMID: 34096197 PMCID: PMC8336510 DOI: 10.1002/advs.202004595] [Citation(s) in RCA: 32] [Impact Index Per Article: 10.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/27/2020] [Revised: 04/14/2021] [Indexed: 05/05/2023]
Abstract
Innate cell function can be artificially engineered and reprogrammed by introducing biomolecules, such as DNAs, RNAs, plasmid DNAs, proteins, or nanomaterials, into the cytosol or nucleus. This process of delivering exogenous cargos into living cells is referred to as intracellular delivery. For instance, clustered regularly interspaced short palindromic repeats (CRISPR)-Cas9 gene editing begins with internalizing Cas9 protein and guide RNA into cells, and chimeric antigen receptor-T (CAR-T) cells are prepared by delivering CAR genes into T lymphocytes for cancer immunotherapies. To deliver external biomolecules into cells, tools, including viral vectors, and electroporation have been traditionally used; however, they are suboptimal for achieving high levels of intracellular delivery while preserving cell viability, phenotype, and function. Notably, as emerging solutions, microfluidic and nanofluidic approaches have shown remarkable potential for addressing this open challenge. This review provides an overview of recent advances in microfluidic and nanofluidic intracellular delivery strategies and discusses new opportunities and challenges for clinical applications. Furthermore, key considerations for future efforts to develop microfluidics- and nanofluidics-enabled next-generation intracellular delivery platforms are outlined.
Collapse
Affiliation(s)
- Jeongsoo Hur
- School of Biomedical EngineeringKorea UniversitySeoul02841Republic of Korea
| | - Aram J. Chung
- School of Biomedical EngineeringInterdisciplinary Program in Precision Public HealthKorea UniversitySeoul02841Republic of Korea
| |
Collapse
|
18
|
Salari A, Appak-Baskoy S, Coe IR, Abousawan J, Antonescu CN, Tsai SSH, Kolios MC. Dosage-controlled intracellular delivery mediated by acoustofluidics for lab on a chip applications. LAB ON A CHIP 2021; 21:1788-1797. [PMID: 33734246 DOI: 10.1039/d0lc01303j] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Biological research and many cell-based therapies rely on the successful delivery of cargo materials into cells. Intracellular delivery in an in vitro setting refers to a variety of physical and biochemical techniques developed for conducting rapid and efficient transport of materials across the plasma membrane. Generally, the techniques that are time-efficient (e.g., electroporation) suffer from heterogeneity and low cellular viability, and those that are precise (e.g., microinjection) suffer from low-throughput and are labor-intensive. Here, we present a novel in vitro microfluidic strategy for intracellular delivery, which is based on the acoustic excitation of adherent cells. Strong mechanical oscillations, mediated by Lamb waves, inside a microfluidic channel facilitate the cellular uptake of different size (e.g., 3-500 kDa, plasmid encoding EGFP) cargo materials through endocytic pathways. We demonstrate successful delivery of 500 kDa dextran to various adherent cell lines with unprecedented efficiency in the range of 65-85% above control. We also show that actuation voltage and treatment duration can be tuned to control the dosage of delivered substances. High viability (≥91%), versatility across different cargo materials and various adherent cell lines, scalability to hundreds of thousands of cells per treatment, portability, and ease-of-operation are among the unique features of this acoustofluidic strategy. Potential applications include targeting through endocytosis-dependant pathways in cellular disorders, such as lysosomal storage diseases, which other physical methods are unable to address. This novel acoustofluidic method achieves rapid, uniform, and scalable delivery of material into cells, and may find utility in lab-on-a-chip applications.
Collapse
Affiliation(s)
- Alinaghi Salari
- Institute for Biomedical Engineering, Science and Technology (iBEST), Toronto, ON M5B 1T8, Canada and Biomedical Engineering Graduate Program, Ryerson University, Toronto, ON M5B 2K3, Canada
| | - Sila Appak-Baskoy
- Institute for Biomedical Engineering, Science and Technology (iBEST), Toronto, ON M5B 1T8, Canada and Department of Chemistry and Biology, Ryerson University, Toronto, ON M5B 2K3, Canada
| | - Imogen R Coe
- Institute for Biomedical Engineering, Science and Technology (iBEST), Toronto, ON M5B 1T8, Canada and Department of Chemistry and Biology, Ryerson University, Toronto, ON M5B 2K3, Canada and Molecular Science Graduate Program, Ryerson University, Toronto, ON M5B2K3, Canada
| | - John Abousawan
- Department of Chemistry and Biology, Ryerson University, Toronto, ON M5B 2K3, Canada and Molecular Science Graduate Program, Ryerson University, Toronto, ON M5B2K3, Canada
| | - Costin N Antonescu
- Department of Chemistry and Biology, Ryerson University, Toronto, ON M5B 2K3, Canada and Molecular Science Graduate Program, Ryerson University, Toronto, ON M5B2K3, Canada
| | - Scott S H Tsai
- Institute for Biomedical Engineering, Science and Technology (iBEST), Toronto, ON M5B 1T8, Canada and Department of Mechanical and Industrial Engineering, Ryerson University, Toronto, ON M5B 2K3, Canada.
| | - Michael C Kolios
- Institute for Biomedical Engineering, Science and Technology (iBEST), Toronto, ON M5B 1T8, Canada and Department of Physics, Ryerson University, Toronto, ON M5B 2K3, Canada.
| |
Collapse
|
19
|
Morshedi Rad D, Alsadat Rad M, Razavi Bazaz S, Kashaninejad N, Jin D, Ebrahimi Warkiani M. A Comprehensive Review on Intracellular Delivery. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2021; 33:e2005363. [PMID: 33594744 DOI: 10.1002/adma.202005363] [Citation(s) in RCA: 60] [Impact Index Per Article: 20.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/07/2020] [Revised: 09/22/2020] [Indexed: 05/22/2023]
Abstract
Intracellular delivery is considered an indispensable process for various studies, ranging from medical applications (cell-based therapy) to fundamental (genome-editing) and industrial (biomanufacture) approaches. Conventional macroscale delivery systems critically suffer from such issues as low cell viability, cytotoxicity, and inconsistent material delivery, which have opened up an interest in the development of more efficient intracellular delivery systems. In line with the advances in microfluidics and nanotechnology, intracellular delivery based on micro- and nanoengineered platforms has progressed rapidly and held great promises owing to their unique features. These approaches have been advanced to introduce a smorgasbord of diverse cargoes into various cell types with the maximum efficiency and the highest precision. This review differentiates macro-, micro-, and nanoengineered approaches for intracellular delivery. The macroengineered delivery platforms are first summarized and then each method is categorized based on whether it employs a carrier- or membrane-disruption-mediated mechanism to load cargoes inside the cells. Second, particular emphasis is placed on the micro- and nanoengineered advances in the delivery of biomolecules inside the cells. Furthermore, the applications and challenges of the established and emerging delivery approaches are summarized. The topic is concluded by evaluating the future perspective of intracellular delivery toward the micro- and nanoengineered approaches.
Collapse
Affiliation(s)
- Dorsa Morshedi Rad
- School of Biomedical Engineering, University of Technology Sydney, Sydney, NSW, 2007, Australia
- Institute for Biomedical Materials & Devices (IBMD), Faculty of Science, University of Technology Sydney, Sydney, NSW, 2007, Australia
| | - Maryam Alsadat Rad
- School of Biomedical Engineering, University of Technology Sydney, Sydney, NSW, 2007, Australia
- Institute for Biomedical Materials & Devices (IBMD), Faculty of Science, University of Technology Sydney, Sydney, NSW, 2007, Australia
| | - Sajad Razavi Bazaz
- School of Biomedical Engineering, University of Technology Sydney, Sydney, NSW, 2007, Australia
- Institute for Biomedical Materials & Devices (IBMD), Faculty of Science, University of Technology Sydney, Sydney, NSW, 2007, Australia
| | - Navid Kashaninejad
- School of Biomedical Engineering, University of Technology Sydney, Sydney, NSW, 2007, Australia
- Institute for Biomedical Materials & Devices (IBMD), Faculty of Science, University of Technology Sydney, Sydney, NSW, 2007, Australia
| | - Dayong Jin
- Institute for Biomedical Materials & Devices (IBMD), Faculty of Science, University of Technology Sydney, Sydney, NSW, 2007, Australia
- School of Life Sciences, Faculty of Science, University of Technology Sydney, Sydney, NSW, 2007, Australia
| | - Majid Ebrahimi Warkiani
- School of Biomedical Engineering, University of Technology Sydney, Sydney, NSW, 2007, Australia
- Institute for Biomedical Materials & Devices (IBMD), Faculty of Science, University of Technology Sydney, Sydney, NSW, 2007, Australia
- Institute of Molecular Medicine, Sechenov University, Moscow, 119991, Russia
| |
Collapse
|
20
|
Zevnik J, Dular M. Cavitation bubble interaction with a rigid spherical particle on a microscale. ULTRASONICS SONOCHEMISTRY 2020; 69:105252. [PMID: 32682313 DOI: 10.1016/j.ultsonch.2020.105252] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/03/2020] [Revised: 05/27/2020] [Accepted: 07/06/2020] [Indexed: 05/09/2023]
Abstract
Cavitation bubble collapse close to a submerged sphere on a microscale is investigated numerically using a finite volume method in order to determine the likelihood of previously suspected mechanical effects to cause bacterial cell damage, such as impact of a high speed water jet, propagation of bubble emitted shock waves, shear loads, and thermal loads. A grid convergence study and validation of the employed axisymmetric numerical model against the Gilmore's equation is performed for a case of a single microbubble collapse due to a sudden ambient pressure increase. Numerical simulations of bubble-sphere interaction corresponding to different values of nondimensional bubble-sphere standoff distance δ and their size ratio ε are carried out. The obtained results show vastly different bubble collapse dynamics across the considered parameter space, from the development of a fast thin annular jet towards the sphere to an almost spherical bubble collapse. Although some similarities in bubble shape progression to previous studies on larger bubbles exist, it can be noticed that bubble jetting is much less likely to occur on the considered scale due to the cushioning effects of surface tension on the intensity of the collapse. Overall, the results show that the mechanical loads on a spherical particle tend to increase with a sphere-bubble size ratio ε, and decrease with their distance δ. Additionally, the results are discussed with respect to bacteria eradication by hydrodynamic cavitation. Potentially harmful mechanical effects of bubble-sphere interaction on a micro scale are identified, namely the collapse-induced shear loads with peaks of a few megapascals and propagation of bubble emitted shock waves, which could cause spatially highly variable compressive loads with peaks of a few hundred megapascals and gradients of 100 MPa/μm.
Collapse
Affiliation(s)
- Jure Zevnik
- University of Ljubljana, Faculty of Mechanical Engineering, Aškerčeva cesta 6, Ljubljana, Slovenia.
| | - Matevž Dular
- University of Ljubljana, Faculty of Mechanical Engineering, Aškerčeva cesta 6, Ljubljana, Slovenia
| |
Collapse
|
21
|
Yang Y, Li Q, Guo X, Tu J, Zhang D. Mechanisms underlying sonoporation: Interaction between microbubbles and cells. ULTRASONICS SONOCHEMISTRY 2020; 67:105096. [PMID: 32278246 DOI: 10.1016/j.ultsonch.2020.105096] [Citation(s) in RCA: 71] [Impact Index Per Article: 17.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/23/2020] [Revised: 03/21/2020] [Accepted: 03/24/2020] [Indexed: 05/04/2023]
Abstract
The past several decades have witnessed great progress in "smart drug delivery", an advance technology that can deliver genes or drugs into specific locations of patients' body with enhanced delivery efficiency. Ultrasound-activated mechanical force induced by the interactions between microbubbles and cells, which can stimulate so-called "sonoporation" process, has been regarded as one of the most promising candidates to realize spatiotemporal-controllable drug delivery to selected regions. Both experimental and numerical studies were performed to get in-depth understanding on how the microbubbles interact with cells during sonoporation processes, under different impact parameters. The current work gives an overview of the general mechanism underlying microbubble-mediated sonoporation, and the possible impact factors (e.g., the properties of cavitation agents and cells, acoustical driving parameters and bubble/cell micro-environment) that could affect sonoporation outcomes. Finally, current progress and considerations of sonoporation in clinical applications are reviewed also.
Collapse
Affiliation(s)
- Yanye Yang
- Key Laboratory of Modern Acoustics (MOE), Department of Physics, Collaborative Innovation Center of Advanced Microstructure, Nanjing University, Nanjing 210093, China
| | - Qunying Li
- Department of Ultrasound in Medicine, the Second Affiliated Hospital of Zhejiang University, School of Medicine, Zhejiang University, Hangzhou 310009, China
| | - Xiasheng Guo
- Key Laboratory of Modern Acoustics (MOE), Department of Physics, Collaborative Innovation Center of Advanced Microstructure, Nanjing University, Nanjing 210093, China
| | - Juan Tu
- Key Laboratory of Modern Acoustics (MOE), Department of Physics, Collaborative Innovation Center of Advanced Microstructure, Nanjing University, Nanjing 210093, China.
| | - Dong Zhang
- Key Laboratory of Modern Acoustics (MOE), Department of Physics, Collaborative Innovation Center of Advanced Microstructure, Nanjing University, Nanjing 210093, China; The State Key Laboratory of Acoustics, Chinese Academy of Science, Beijing 10080, China
| |
Collapse
|
22
|
Chowdhury SM, Abou-Elkacem L, Lee T, Dahl J, Lutz AM. Ultrasound and microbubble mediated therapeutic delivery: Underlying mechanisms and future outlook. J Control Release 2020; 326:75-90. [PMID: 32554041 DOI: 10.1016/j.jconrel.2020.06.008] [Citation(s) in RCA: 120] [Impact Index Per Article: 30.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2020] [Revised: 06/06/2020] [Accepted: 06/09/2020] [Indexed: 12/20/2022]
Abstract
Beyond the emerging field of oncological ultrasound molecular imaging, the recent significant advancements in ultrasound and contrast agent technology have paved the way for therapeutic ultrasound mediated microbubble oscillation and has shown that this approach is capable of increasing the permeability of microvessel walls while also initiating enhanced extravasation and drug delivery into target tissues. In addition, a large number of preclinical studies have demonstrated that ultrasound alone or combined with microbubbles can efficiently increase cell membrane permeability resulting in enhanced tissue distribution and intracellular drug delivery of molecules, nanoparticles, and other therapeutic agents. The mechanism behind the enhanced permeability is the temporary creation of pores in cell membranes through a phenomenon called sonoporation by high-intensity ultrasound and microbubbles or cavitation agents. At low ultrasound intensities (0.3-3 W/cm2), sonoporation may be caused by microbubbles oscillating in a stable motion, also known as stable cavitation. In contrast, at higher ultrasound intensities (greater than 3 W/cm2), sonoporation usually occurs through inertial cavitation that accompanies explosive growth and collapse of the microbubbles. Sonoporation has been shown to be a highly effective method to improve drug uptake through microbubble potentiated enhancement of microvascular permeability. In this review, the therapeutic strategy of using ultrasound for improved drug delivery are summarized with the special focus on cancer therapy. Additionally, we discuss the progress, challenges, and future of ultrasound-mediated drug delivery towards clinical translation.
Collapse
Affiliation(s)
- Sayan Mullick Chowdhury
- Department of Radiology, Molecular Imaging Program at Stanford, Stanford University School of Medicine, Stanford, CA, USA
| | - Lotfi Abou-Elkacem
- Department of Radiology, Molecular Imaging Program at Stanford, Stanford University School of Medicine, Stanford, CA, USA
| | - Taehwa Lee
- Department of Radiology, Molecular Imaging Program at Stanford, Stanford University School of Medicine, Stanford, CA, USA
| | - Jeremy Dahl
- Department of Radiology, Molecular Imaging Program at Stanford, Stanford University School of Medicine, Stanford, CA, USA
| | - Amelie M Lutz
- Department of Radiology, Molecular Imaging Program at Stanford, Stanford University School of Medicine, Stanford, CA, USA.
| |
Collapse
|
23
|
Cell Lysis Based on an Oscillating Microbubble Array. MICROMACHINES 2020; 11:mi11030288. [PMID: 32164279 PMCID: PMC7143388 DOI: 10.3390/mi11030288] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/14/2019] [Revised: 03/04/2020] [Accepted: 03/08/2020] [Indexed: 01/17/2023]
Abstract
Cell lysis is a process of breaking cell membranes to release intracellular substances such as DNA, RNA, protein, or organelles from a cell. The detection of DNA, RNA, or protein from the lysed cells is of importance for cancer diagnostics and drug screening. In this study, we develop a microbubble array that enables the realization of multiple cell lysis induced by the shear stress resulting from the individual oscillating microbubbles. The oscillating microbubbles in the channel have similar vibration amplitudes, and the intracellular substances can be released from the individual cells efficiently. Moreover, the efficiency of cell lysis increases with increments of input voltage and sonication time. By means of DNA agarose-gel electrophoresis, a sufficient extraction amount of DNA released from the lysed cells can be detected, and there is no significant difference in lysis efficiency when compared to cell lysis achieved using commercial kits. With the advantages of the simple manufacturing process, low cost, high efficiency, and high speed, this device can serve as an efficient and versatile tool for the single-cell sequencing of cell biology research, disease diagnosis, and stem cell therapy.
Collapse
|
24
|
Meng L, Liu X, Wang Y, Zhang W, Zhou W, Cai F, Li F, Wu J, Xu L, Niu L, Zheng H. Sonoporation of Cells by a Parallel Stable Cavitation Microbubble Array. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2019; 6:1900557. [PMID: 31508275 PMCID: PMC6724477 DOI: 10.1002/advs.201900557] [Citation(s) in RCA: 31] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/12/2019] [Revised: 05/15/2019] [Indexed: 05/06/2023]
Abstract
Sonoporation is a targeted drug delivery technique that employs cavitation microbubbles to generate transient pores in the cell membrane, allowing foreign substances to enter cells by passing through the pores. Due to the broad size distribution of microbubbles, cavitation events appear to be a random process, making it difficult to achieve controllable and efficient sonoporation. In this work a technique is reported using a microfluidic device that enables in parallel modulation of membrane permeability by an oscillating microbubble array. Multirectangular channels of uniform size are created at the sidewall to generate an array of monodispersed microbubbles, which oscillate with almost the same amplitude and resonant frequency, ensuring homogeneous sonoporation with high efficacy. Stable harmonic and high harmonic signals emitted by individual oscillating microbubbles are detected by a laser Doppler vibrometer, which indicates stable cavitation occurred. Under the influence of the acoustic radiation forces induced by the oscillating microbubble, single cells can be trapped at an oscillating microbubble surface. The sonoporation of single cells is directly influenced by the individual oscillating microbubble. The parallel sonoporation of multiple cells is achieved with an efficiency of 96.6 ± 1.74% at an acoustic pressure as low as 41.7 kPa.
Collapse
Affiliation(s)
- Long Meng
- Paul C. Lauterbur Research Center for Biomedical ImagingInstitute of Biomedical and Health EngineeringShenzhen Institutes of Advanced TechnologyChinese Academy of Sciences1068 Xueyuan AvenueShenzhen518055China
- CAS Key Laboratory of Health InformaticsShenzhen Institutes of Advanced TechnologyChinese Academy of Sciences1068 Xueyuan AvenueShenzhen518055China
| | - Xiufang Liu
- Paul C. Lauterbur Research Center for Biomedical ImagingInstitute of Biomedical and Health EngineeringShenzhen Institutes of Advanced TechnologyChinese Academy of Sciences1068 Xueyuan AvenueShenzhen518055China
- Sino‐Dutch Biomedical and Information Engineering SchoolNortheastern University195 Innovation roadShenyang110169China
| | - Yuchen Wang
- Paul C. Lauterbur Research Center for Biomedical ImagingInstitute of Biomedical and Health EngineeringShenzhen Institutes of Advanced TechnologyChinese Academy of Sciences1068 Xueyuan AvenueShenzhen518055China
- Faculty of Engineering and ArchitectureGhent UniversityJozef Plateaustraat 229000GhentBelgium
| | - Wenjun Zhang
- Paul C. Lauterbur Research Center for Biomedical ImagingInstitute of Biomedical and Health EngineeringShenzhen Institutes of Advanced TechnologyChinese Academy of Sciences1068 Xueyuan AvenueShenzhen518055China
- Key Laboratory of E&MMinistry of Education & Zhejiang ProvinceZhejiang University of Technology18 Chaowang RoadHangzhou310014China
| | - Wei Zhou
- Paul C. Lauterbur Research Center for Biomedical ImagingInstitute of Biomedical and Health EngineeringShenzhen Institutes of Advanced TechnologyChinese Academy of Sciences1068 Xueyuan AvenueShenzhen518055China
| | - Feiyan Cai
- Paul C. Lauterbur Research Center for Biomedical ImagingInstitute of Biomedical and Health EngineeringShenzhen Institutes of Advanced TechnologyChinese Academy of Sciences1068 Xueyuan AvenueShenzhen518055China
- CAS Key Laboratory of Health InformaticsShenzhen Institutes of Advanced TechnologyChinese Academy of Sciences1068 Xueyuan AvenueShenzhen518055China
| | - Fei Li
- Paul C. Lauterbur Research Center for Biomedical ImagingInstitute of Biomedical and Health EngineeringShenzhen Institutes of Advanced TechnologyChinese Academy of Sciences1068 Xueyuan AvenueShenzhen518055China
- CAS Key Laboratory of Health InformaticsShenzhen Institutes of Advanced TechnologyChinese Academy of Sciences1068 Xueyuan AvenueShenzhen518055China
| | - Junru Wu
- Department of PhysicsUniversity of VermontBurlingtonVT05405USA
| | - Lisheng Xu
- Sino‐Dutch Biomedical and Information Engineering SchoolNortheastern University195 Innovation roadShenyang110169China
| | - Lili Niu
- Paul C. Lauterbur Research Center for Biomedical ImagingInstitute of Biomedical and Health EngineeringShenzhen Institutes of Advanced TechnologyChinese Academy of Sciences1068 Xueyuan AvenueShenzhen518055China
- CAS Key Laboratory of Health InformaticsShenzhen Institutes of Advanced TechnologyChinese Academy of Sciences1068 Xueyuan AvenueShenzhen518055China
| | - Hairong Zheng
- Paul C. Lauterbur Research Center for Biomedical ImagingInstitute of Biomedical and Health EngineeringShenzhen Institutes of Advanced TechnologyChinese Academy of Sciences1068 Xueyuan AvenueShenzhen518055China
- CAS Key Laboratory of Health InformaticsShenzhen Institutes of Advanced TechnologyChinese Academy of Sciences1068 Xueyuan AvenueShenzhen518055China
| |
Collapse
|
25
|
Roovers S, Segers T, Lajoinie G, Deprez J, Versluis M, De Smedt SC, Lentacker I. The Role of Ultrasound-Driven Microbubble Dynamics in Drug Delivery: From Microbubble Fundamentals to Clinical Translation. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2019; 35:10173-10191. [PMID: 30653325 DOI: 10.1021/acs.langmuir.8b03779] [Citation(s) in RCA: 118] [Impact Index Per Article: 23.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
Abstract
In the last couple of decades, ultrasound-driven microbubbles have proven excellent candidates for local drug delivery applications. Besides being useful drug carriers, microbubbles have demonstrated the ability to enhance cell and tissue permeability and, as a consequence, drug uptake herein. Notwithstanding the large amount of evidence for their therapeutic efficacy, open issues remain. Because of the vast number of ultrasound- and microbubble-related parameters that can be altered and the variability in different models, the translation from basic research to (pre)clinical studies has been hindered. This review aims at connecting the knowledge gained from fundamental microbubble studies to the therapeutic efficacy seen in in vitro and in vivo studies, with an emphasis on a better understanding of the response of a microbubble upon exposure to ultrasound and its interaction with cells and tissues. More specifically, we address the acoustic settings and microbubble-related parameters (i.e., bubble size and physicochemistry of the bubble shell) that play a key role in microbubble-cell interactions and in the associated therapeutic outcome. Additionally, new techniques that may provide additional control over the treatment, such as monodisperse microbubble formulations, tunable ultrasound scanners, and cavitation detection techniques, are discussed. An in-depth understanding of the aspects presented in this work could eventually lead the way to more efficient and tailored microbubble-assisted ultrasound therapy in the future.
Collapse
Affiliation(s)
- Silke Roovers
- Laboratory of General Biochemistry and Physical Pharmacy, Ghent Research Group on Nanomedicine, Faculty of Pharmaceutical Sciences , Ghent University , Ottergemsesteenweg 460 , Ghent , Belgium
| | - Tim Segers
- Physics of Fluids Group, MESA+ Institute for Nanotechnology and Technical Medical (TechMed) Center , University of Twente , P.O. Box 217, 7500 AE Enschede , The Netherlands
| | - Guillaume Lajoinie
- Physics of Fluids Group, MESA+ Institute for Nanotechnology and Technical Medical (TechMed) Center , University of Twente , P.O. Box 217, 7500 AE Enschede , The Netherlands
| | - Joke Deprez
- Laboratory of General Biochemistry and Physical Pharmacy, Ghent Research Group on Nanomedicine, Faculty of Pharmaceutical Sciences , Ghent University , Ottergemsesteenweg 460 , Ghent , Belgium
| | - Michel Versluis
- Physics of Fluids Group, MESA+ Institute for Nanotechnology and Technical Medical (TechMed) Center , University of Twente , P.O. Box 217, 7500 AE Enschede , The Netherlands
| | - Stefaan C De Smedt
- Laboratory of General Biochemistry and Physical Pharmacy, Ghent Research Group on Nanomedicine, Faculty of Pharmaceutical Sciences , Ghent University , Ottergemsesteenweg 460 , Ghent , Belgium
| | - Ine Lentacker
- Laboratory of General Biochemistry and Physical Pharmacy, Ghent Research Group on Nanomedicine, Faculty of Pharmaceutical Sciences , Ghent University , Ottergemsesteenweg 460 , Ghent , Belgium
| |
Collapse
|
26
|
Escoffre JM, Bouakaz A. Minireview: Biophysical Mechanisms of Cell Membrane Sonopermeabilization. Knowns and Unknowns. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2019; 35:10151-10165. [PMID: 30525655 DOI: 10.1021/acs.langmuir.8b03538] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
Microbubble-assisted ultrasound has emerged as a promising method for the delivery of low-molecular-weight chemotherapeutic molecules, nucleic acids, therapeutic peptides, and antibodies in vitro and in vivo. Its clinical applications are under investigation for local delivery drug in oncology and neurology. However, the biophysical mechanisms supporting the acoustically mediated membrane permeabilization are not fully established. This review describes the present state of the investigations concerning the acoustically mediated stimuli (i.e., mechanical, chemical, and thermal stimuli) as well as the molecular and cellular actors (i.e., membrane pores and endocytosis) involved in the reversible membrane permeabilization process. The different hypotheses, which were proposed to give a biophysical description of the membrane permeabilization, are critically discussed.
Collapse
Affiliation(s)
- Jean-Michel Escoffre
- UMR 1253, iBrain, Université de Tours, Inserm , 10 bd Tonnellé , 37032 Tours Cedex 1, France
| | - Ayache Bouakaz
- UMR 1253, iBrain, Université de Tours, Inserm , 10 bd Tonnellé , 37032 Tours Cedex 1, France
| |
Collapse
|
27
|
Pereiro I, Fomitcheva Khartchenko A, Petrini L, Kaigala GV. Nip the bubble in the bud: a guide to avoid gas nucleation in microfluidics. LAB ON A CHIP 2019; 19:2296-2314. [PMID: 31168556 DOI: 10.1039/c9lc00211a] [Citation(s) in RCA: 63] [Impact Index Per Article: 12.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
Gas bubbles are almost a routine occurrence encountered by researchers working in the field of microfluidics. The spontaneous and unexpected nature of gas bubbles represents a major challenge for experimentalists and a stumbling block for the translation of microfluidic concepts to commercial products. This is a startling example of successful scientific results in the field overshadowing the practical hurdles of day-to-day usage. We however believe such hurdles can be overcome with a sound understanding of the underlying conditions that lead to bubble formation. In this tutorial, we focus on the two main conditions that result in bubble nucleation: surface nuclei and gas supersaturation in liquids. Key theoretical concepts such as Henry's law, Laplace pressure, the role of surface properties, nanobubbles and surfactants are presented along with a view of practical implementations that serve as preventive and curative measures. These considerations include not only microfluidic chip design and bubble traps but also often-overlooked conditions that regulate bubble formation, such as gas saturation under pressure or temperature gradients. Scenarios involving electrolysis, laser and acoustic cavitation or T-junction/co-flow geometries are also explored to provide the reader with a broader understanding on the topic. Interestingly, despite their often-disruptive nature, gas bubbles have also been cleverly utilized for certain practical applications, which we briefly review. We hope this tutorial will provide a reference guide in helping to deal with a familiar foe, the "bubble".
Collapse
Affiliation(s)
- Iago Pereiro
- IBM Research - Zurich, Säumerstrasse 4, Rüschlikon, CH-8803, Switzerland.
| | | | | | | |
Collapse
|
28
|
Fatsis-Kavalopoulos N, O'Callaghan P, Xie B, Hernández Vera R, Idevall-Hagren O, Kreuger J. Formation of precisely composed cancer cell clusters using a cell assembly generator (CAGE) for studying paracrine signaling at single-cell resolution. LAB ON A CHIP 2019; 19:1071-1081. [PMID: 30783638 DOI: 10.1039/c8lc01153b] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/16/2023]
Abstract
The function and behaviour of any given cell in a healthy tissue, or in a tumor, is affected by interactions with its neighboring cells. It is therefore important to create methods that allow for reconstruction of tissue niches in vitro for studies of cell-cell signaling and associated cell behaviour. To this end we created the cell assembly generator (CAGE), a microfluidic device which enables the organization of different cell types into precise cell clusters in a flow chamber compatible with high-resolution microscopy. In proof-of-concept paracrine signalling experiments, 4-cell clusters consisting of one pancreatic β-cell and three breast cancer cells were formed. It has previously been established that extracellular ATP induces calcium (Ca2+) release from the endoplasmic reticulum (ER) to the cytosol before it is cleared back into the ER via sarcoplasmic/ER Ca2+ ATPase (SERCA) pumps. Here, ATP release from the β-cell was stimulated by depolarization, and dynamic changes in Ca2+ levels in the adjacent cancer cells measured using imaging of the calcium indicator Fluo-4. We established that changes in the concentration of cytosolic Ca2+ in the cancer cells were proportional to the distance from the ATP-releasing β-cell. Additionally, we established that the relationship between distance and cytosolic calcium changes were dependent on Ca2+-release from the ER using 5-cell clusters composed of one β-cell, two untreated cancer cells and two cancer cells pretreated with Thapsigargin (to deplete the ER of Ca2+). These experiments show that the CAGE can be used to create exact cell clusters, which affords precise control for reductionist studies of cell-cell signalling and permits the formation of heterogenous cell models of specific tissue niches.
Collapse
|
29
|
Stewart MP, Langer R, Jensen KF. Intracellular Delivery by Membrane Disruption: Mechanisms, Strategies, and Concepts. Chem Rev 2018; 118:7409-7531. [PMID: 30052023 PMCID: PMC6763210 DOI: 10.1021/acs.chemrev.7b00678] [Citation(s) in RCA: 406] [Impact Index Per Article: 67.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Intracellular delivery is a key step in biological research and has enabled decades of biomedical discoveries. It is also becoming increasingly important in industrial and medical applications ranging from biomanufacture to cell-based therapies. Here, we review techniques for membrane disruption-based intracellular delivery from 1911 until the present. These methods achieve rapid, direct, and universal delivery of almost any cargo molecule or material that can be dispersed in solution. We start by covering the motivations for intracellular delivery and the challenges associated with the different cargo types-small molecules, proteins/peptides, nucleic acids, synthetic nanomaterials, and large cargo. The review then presents a broad comparison of delivery strategies followed by an analysis of membrane disruption mechanisms and the biology of the cell response. We cover mechanical, electrical, thermal, optical, and chemical strategies of membrane disruption with a particular emphasis on their applications and challenges to implementation. Throughout, we highlight specific mechanisms of membrane disruption and suggest areas in need of further experimentation. We hope the concepts discussed in our review inspire scientists and engineers with further ideas to improve intracellular delivery.
Collapse
Affiliation(s)
- Martin P. Stewart
- Department of Chemical Engineering, Massachusetts Institute
of Technology, Cambridge, USA
- The Koch Institute for Integrative Cancer Research,
Massachusetts Institute of Technology, Cambridge, USA
| | - Robert Langer
- Department of Chemical Engineering, Massachusetts Institute
of Technology, Cambridge, USA
- The Koch Institute for Integrative Cancer Research,
Massachusetts Institute of Technology, Cambridge, USA
| | - Klavs F. Jensen
- Department of Chemical Engineering, Massachusetts Institute
of Technology, Cambridge, USA
| |
Collapse
|
30
|
Li J, Zhao F, Deng Y, Liu D, Chen CH, Shih WC. Photothermal generation of programmable microbubble array on nanoporous gold disks. OPTICS EXPRESS 2018; 26:16893-16902. [PMID: 30119508 DOI: 10.1364/oe.26.016893] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/01/2018] [Accepted: 06/04/2018] [Indexed: 05/25/2023]
Abstract
We present a novel technique to generate microbubbles photothermally by continuous-wave laser irradiation of nanoporous gold disk (NPGD) array covered microfluidic channels. When a single laser spot is focused on the NPGDs, a microbubble can be generated with controlled size by adjusting the laser power. The dynamics of both bubble growth and shrinkage are studied. Using computer-generated holography on a spatial light modulator (SLM), simultaneous generation of multiple microbubbles at arbitrary locations with independent control is demonstrated. A potential application of flow manipulation is demonstrated using a microfluidic X-shaped junction. The advantages of this technique are flexible bubble generation locations, long bubble lifetimes, no need for light-adsorbing dyes, high controllability over bubble size, and relatively lower power consumption.
Collapse
|
31
|
López-Marín LM, Rivera AL, Fernández F, Loske AM. Shock wave-induced permeabilization of mammalian cells. Phys Life Rev 2018; 26-27:1-38. [PMID: 29685859 DOI: 10.1016/j.plrev.2018.03.001] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2017] [Revised: 02/12/2018] [Accepted: 02/26/2018] [Indexed: 12/18/2022]
Abstract
Controlled permeabilization of mammalian cell membranes is fundamental to develop gene and cell therapies based on macromolecular cargo delivery, a process that emerged against an increasing number of health afflictions, including genetic disorders, cancer and infections. Viral vectors have been successfully used for macromolecular delivery; however, they may have unpredictable side effects and have been limited to life-threatening cases. Thus, several chemical and physical methods have been explored to introduce drugs, vaccines, and nucleic acids into cells. One of the most appealing physical methods to deliver genes into cells is shock wave-induced poration. High-speed microjets of fluid, emitted due to the collapse of microbubbles after shock wave passage, represent the most significant mechanism that contributes to cell membrane poration by this technique. Herein, progress in shock wave-induced permeabilization of mammalian cells is presented. After covering the main concepts related to molecular strategies whose applications depend on safer drug delivery methods, the physics behind shock wave phenomena is described. Insights into the use of shock waves for cell membrane permeation are discussed, along with an overview of the two major biomedical applications thereof-i.e., genetic modification and anti-cancer shock wave-assisted chemotherapy. The aim of this review is to summarize 30 years of data showing underwater shock waves as a safe, noninvasive method for macromolecular delivery into mammalian cells, encouraging the development of further research, which is still required before the introduction of this promising tool into clinical practice.
Collapse
Affiliation(s)
- Luz M López-Marín
- Centro de Física Aplicada y Tecnología Avanzada, Universidad Nacional Autónoma de México, Boulevard Juriquilla 3001, 76230 Querétaro, Qro., Mexico.
| | - Ana Leonor Rivera
- Instituto de Ciencias Nucleares & Centro de Ciencias de la Complejidad, Universidad Nacional Autónoma de México, Ciudad Universitaria, 04510 Ciudad de México, Mexico.
| | - Francisco Fernández
- Centro de Física Aplicada y Tecnología Avanzada, Universidad Nacional Autónoma de México, Boulevard Juriquilla 3001, 76230 Querétaro, Qro., Mexico.
| | - Achim M Loske
- Centro de Física Aplicada y Tecnología Avanzada, Universidad Nacional Autónoma de México, Boulevard Juriquilla 3001, 76230 Querétaro, Qro., Mexico.
| |
Collapse
|
32
|
Xing X, Pan Y, Yobas L. A Low-Backpressure Single-Cell Point Constriction for Cytosolic Delivery Based on Rapid Membrane Deformations. Anal Chem 2018; 90:1836-1844. [PMID: 29308899 DOI: 10.1021/acs.analchem.7b03864] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
Mechanically deforming biological cells through microfluidic constrictions is a recently introduced technique for the intracellular delivery of macromolecules possibly through transient membrane pores induced in the process. The technique is attractive for research and clinical applications mainly because it is simple, fast, and effective while being free of adverse effects often associated with well-known techniques that rely on field- or vector-based delivery. In this nascent approach, an utmost and crucial role is played by the constriction, often in rectangular profile, and it squeezes cells only in one dimension. The results achieved suggest that the longer the constriction is the higher the delivery performance. Contrary to this view, we demonstrate here a unique constriction profile that is highly localized (point) and yet returns comparably effective delivery. Point constrictions are of a semiround geometry, forcing cells in both dimensions while introducing very little backpressure to the system, which is a silicon-glass platform wherein constrictions are arranged in series along an array of channels. The influence of the constriction size and count as well as treatment pressure on delivery performance is presented on the basis of the flow-cytometric analyses of HCT116 cells treated using dextran as model molecules. Delivery performance is also presented for common mammalian cell lines including NIH 3T3, HEK293, and MDCK. Moreover, the versatility of the platform is demonstrated in gene knockdown experiments using synthetic siRNA as well as on the delivery of proteins. Target proteins in some cells exhibit nondiffusive distribution profile raising the plausibility of mechanisms other than transient membrane pores.
Collapse
Affiliation(s)
- Xiaoxing Xing
- College of Information Science and Technology, Beijing University of Chemical Technology , Beijing 100029, China
| | | | | |
Collapse
|
33
|
Qin P, Han T, Yu ACH, Xu L. Mechanistic understanding the bioeffects of ultrasound-driven microbubbles to enhance macromolecule delivery. J Control Release 2018; 272:169-181. [PMID: 29305924 DOI: 10.1016/j.jconrel.2018.01.001] [Citation(s) in RCA: 110] [Impact Index Per Article: 18.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2017] [Revised: 01/02/2018] [Accepted: 01/03/2018] [Indexed: 12/17/2022]
Abstract
Ultrasound-driven microbubbles can trigger reversible membrane perforation (sonoporation), open interendothelial junctions and stimulate endocytosis, thereby providing a temporary and reversible time-window for the delivery of macromolecules across biological membranes and endothelial barriers. This time-window is related not only to cavitation events, but also to biological regulatory mechanisms. Mechanistic understanding of the interaction between cavitation events and cells and tissues, as well as the subsequent cellular and molecular responses will lead to new design strategies with improved efficacy and minimized side effects. Recent important progress on the spatiotemporal characteristics of sonoporation, cavitation-induced interendothelial gap and endocytosis, and the spatiotemporal bioeffects and the preliminary biological mechanisms in cavitation-enhanced permeability, has been made. On the basis of the summary of this research progress, this Review outlines the underlying bioeffects and the related biological regulatory mechanisms involved in cavitation-enhanced permeability; provides a critical commentary on the future tasks and directions in this field, including developing a standardized methodology to reveal mechanism-based bioeffects in depth, and designing biology-based treatment strategies to improve efficacy and safety. Such mechanistic understanding the bioeffects that contribute to cavitation-enhanced delivery will accelerate the translation of this approach to the clinic.
Collapse
Affiliation(s)
- Peng Qin
- Department of Instrument Science and Engineering, Shanghai Jiao Tong University, Shanghai, China.
| | - Tao Han
- Department of Instrument Science and Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Alfred C H Yu
- Department of Electrical and Computer Engineering, University of Waterloo, Waterloo, ON, Canada
| | - Lin Xu
- National Key Laboratory of Plant Molecular Genetics, CAS Center for Excellence in Molecular Plant Sciences, Institute of Plant Physiology and Ecology, Shanghai Institutes for Biological Sciences, Chinese Academy of Sciences, Shanghai, China
| |
Collapse
|
34
|
Sengupta A, Gray MD, Kelly SC, Holguin SY, Thadhani NN, Prausnitz MR. Energy Transfer Mechanisms during Molecular Delivery to Cells by Laser-Activated Carbon Nanoparticles. Biophys J 2017; 112:1258-1269. [PMID: 28355552 DOI: 10.1016/j.bpj.2017.02.007] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2016] [Revised: 02/06/2017] [Accepted: 02/07/2017] [Indexed: 11/26/2022] Open
Abstract
Previous studies have shown that exposure of carbon black nanoparticles to nanosecond pulsed near-infrared laser causes intracellular delivery of molecules through hypothesized transient breaks in the cell membrane. The goal of this study is to determine the underlying mechanisms of sequential energy transfer from laser light to nanoparticle to fluid medium to cell. We found that laser pulses on a timescale of 10 ns rapidly heat carbon nanoparticles to temperatures on the order of 1200 K. Heat is transferred from the nanoparticles to the surrounding aqueous medium on a similar timescale, causing vaporization of the surrounding water and generation of acoustic emissions. Nearby cells can be impacted thermally by the hot bubbles and mechanically by fluid mechanical forces to transiently increase cell membrane permeability. The experimental and theoretical results indicate that transfer of momentum and/or heat from the bubbles to the cells are the dominant mechanisms of energy transfer that results in intracellular uptake of molecules. We further conclude that neither thermal expansion of the nanoparticles nor a carbon-steam chemical reaction play a significant role in the observed effects on cells, and that acoustic pressure appears to be concurrent with, but not essential to, the observed bioeffects.
Collapse
Affiliation(s)
- Aritra Sengupta
- School of Chemical and Biomolecular Engineering, Georgia Institute of Technology, Atlanta, Georgia
| | - Michael D Gray
- George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, Georgia
| | - Sean C Kelly
- School of Materials Science and Engineering, Georgia Institute of Technology, Atlanta, Georgia
| | - Stefany Y Holguin
- School of Materials Science and Engineering, Georgia Institute of Technology, Atlanta, Georgia
| | - Naresh N Thadhani
- School of Materials Science and Engineering, Georgia Institute of Technology, Atlanta, Georgia
| | - Mark R Prausnitz
- School of Chemical and Biomolecular Engineering, Georgia Institute of Technology, Atlanta, Georgia.
| |
Collapse
|
35
|
Microfluidic Platform for Parallel Single Cell Analysis for Diagnostic Applications. Methods Mol Biol 2017. [PMID: 28044297 DOI: 10.1007/978-1-4939-6734-6_15] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register]
Abstract
Cell populations are heterogeneous: they can comprise different cell types or even cells at different stages of the cell cycle and/or of biological processes. Furthermore, molecular processes taking place in cells are stochastic in nature. Therefore, cellular analysis must be brought down to the single cell level to get useful insight into biological processes, and to access essential molecular information that would be lost when using a cell population analysis approach. Furthermore, to fully characterize a cell population, ideally, information both at the single cell level and on the whole cell population is required, which calls for analyzing each individual cell in a population in a parallel manner. This single cell level analysis approach is particularly important for diagnostic applications to unravel molecular perturbations at the onset of a disease, to identify biomarkers, and for personalized medicine, not only because of the heterogeneity of the cell sample, but also due to the availability of a reduced amount of cells, or even unique cells. This chapter presents a versatile platform meant for the parallel analysis of individual cells, with a particular focus on diagnostic applications and the analysis of cancer cells. We first describe one essential step of this parallel single cell analysis protocol, which is the trapping of individual cells in dedicated structures. Following this, we report different steps of a whole analytical process, including on-chip cell staining and imaging, cell membrane permeabilization and/or lysis using either chemical or physical means, and retrieval of the cell molecular content in dedicated channels for further analysis. This series of experiments illustrates the versatility of the herein-presented platform and its suitability for various analysis schemes and different analytical purposes.
Collapse
|
36
|
|
37
|
|
38
|
Lajoinie G, De Cock I, Coussios CC, Lentacker I, Le Gac S, Stride E, Versluis M. In vitro methods to study bubble-cell interactions: Fundamentals and therapeutic applications. BIOMICROFLUIDICS 2016; 10:011501. [PMID: 26865903 PMCID: PMC4733084 DOI: 10.1063/1.4940429] [Citation(s) in RCA: 38] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/29/2015] [Accepted: 01/05/2016] [Indexed: 05/08/2023]
Abstract
Besides their use as contrast agents for ultrasound imaging, microbubbles are increasingly studied for a wide range of therapeutic applications. In particular, their ability to enhance the uptake of drugs through the permeabilization of tissues and cell membranes shows great promise. In order to fully understand the numerous paths by which bubbles can interact with cells and the even larger number of possible biological responses from the cells, thorough and extensive work is necessary. In this review, we consider the range of experimental techniques implemented in in vitro studies with the aim of elucidating these microbubble-cell interactions. First of all, the variety of cell types and cell models available are discussed, emphasizing the need for more and more complex models replicating in vivo conditions together with experimental challenges associated with this increased complexity. Second, the different types of stabilized microbubbles and more recently developed droplets and particles are presented, followed by their acoustic or optical excitation methods. Finally, the techniques exploited to study the microbubble-cell interactions are reviewed. These techniques operate over a wide range of timescales, or even off-line, revealing particular aspects or subsequent effects of these interactions. Therefore, knowledge obtained from several techniques must be combined to elucidate the underlying processes.
Collapse
Affiliation(s)
- Guillaume Lajoinie
- Physics of Fluids Group, MESA+ Institute for Nanotechnology, MIRA Institute for Biomedical Technology and Technical Medicine, University of Twente , Enschede, The Netherlands
| | - Ine De Cock
- Laboratory of General Biochemistry and Physical Pharmacy, Ghent Research Group on Nanomedicines, Faculty of Pharmaceutical Sciences, Ghent University , Ghent, Belgium
| | | | - Ine Lentacker
- Laboratory of General Biochemistry and Physical Pharmacy, Ghent Research Group on Nanomedicines, Faculty of Pharmaceutical Sciences, Ghent University , Ghent, Belgium
| | - Séverine Le Gac
- MESA+ Institute for Nanotechnology, MIRA Institute for Biomedical Technology and Technical Medicine, University of Twente , Enschede, The Netherlands
| | - Eleanor Stride
- Institute of Biomedical Engineering, University of Oxford , Oxford, United Kingdom
| | - Michel Versluis
- Physics of Fluids Group, MESA+ Institute for Nanotechnology, MIRA Institute for Biomedical Technology and Technical Medicine, University of Twente , Enschede, The Netherlands
| |
Collapse
|
39
|
Bouakaz A, Zeghimi A, Doinikov AA. Sonoporation: Concept and Mechanisms. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2016; 880:175-89. [PMID: 26486338 DOI: 10.1007/978-3-319-22536-4_10] [Citation(s) in RCA: 60] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/04/2022]
Abstract
Contrast agents for ultrasound are now routinely used for diagnosis and imaging. In recent years, new promising possibilities for targeted drug delivery have been proposed that can be realized by using the microbubble composing ultrasound contrast agents (UCAs). The microbubbles can carry drugs and selectively adhere to specific sites in the human body. This capability, in combination with the effect known as sonoporation, provides great possibilities for localized drug delivery. Sonoporation is a process in which ultrasonically activated UCAs, pulsating nearby biological barriers (cell membrane or endothelial layer), increase their permeability and thereby enhance the extravasation of external substances. In this way drugs and genes can be delivered inside individual cells without serious consequences for the cell viability. Sonoporation has been validated both in-vitro using cell cultures and in-vivo in preclinical studies. However, today, the mechanisms by which molecules cross the biological barriers remain unrevealed despite a number of proposed theories. This chapter will provide a survey of the current studies on various hypotheses regarding the routes by which drugs are incorporated into cells or across the endothelial layer and possible associated microbubble acoustic phenomena.
Collapse
Affiliation(s)
- Ayache Bouakaz
- Inserm Imaging and Ultrasound, INSERM U930, Imagerie et Cerveau, Université François-Rabelais de Tours, Tours, France.
| | - Aya Zeghimi
- Inserm Imaging and Ultrasound, INSERM U930, Imagerie et Cerveau, Université François-Rabelais de Tours, Tours, France
| | - Alexander A Doinikov
- Inserm Imaging and Ultrasound, INSERM U930, Imagerie et Cerveau, Université François-Rabelais de Tours, Tours, France
| |
Collapse
|
40
|
Quantifying cell adhesion through impingement of a controlled microjet. Biophys J 2015; 108:23-31. [PMID: 25564849 DOI: 10.1016/j.bpj.2014.10.071] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2013] [Revised: 10/08/2014] [Accepted: 10/22/2014] [Indexed: 11/20/2022] Open
Abstract
The impingement of a submerged, liquid jet onto a cell-covered surface allows assessing cell attachment on surfaces in a straightforward and quantitative manner and in real time, yielding valuable information on cell adhesion. However, this approach is insufficiently characterized for reliable and routine use. In this work, we both model and measure the shear stress exerted by the jet on the impingement surface in the micrometer-domain, and subsequently correlate this to jet-induced cell detachment. The measured and numerically calculated shear stress data are in good agreement with each other, and with previously published values. Real-time monitoring of the cell detachment reveals the creation of a circular cell-free area upon jet impingement, with two successive detachment regimes: 1), a dynamic regime, during which the cell-free area grows as a function of both the maximum shear stress exerted by the jet and the jet diameter; followed by 2), a stationary regime, with no further evolution of the cell-free area. For the latter regime, which is relevant for cell adhesion strength assessment, a relationship between the jet Reynolds number, the cell-free area, and the cell adhesion strength is proposed. To illustrate the capability of the technique, the adhesion strength of HeLa cervical cancer cells is determined ((34 ± 14) N/m(2)). Real-time visualization of cell detachment in the dynamic regime shows that cells detach either cell-by-cell or by collectively (for which intact parts of the monolayer detach as cell sheets). This process is dictated by the cell monolayer density, with a typical threshold of (1.8 ± 0.2) × 10(9) cells/m(2), above which the collective behavior is mostly observed. The jet impingement method presents great promises for the field of tissue engineering, as the influence of both the shear stress and the surface characteristics on cell adhesion can be systematically studied.
Collapse
|
41
|
Muleki Seya P, Fouqueray M, Ngo J, Poizat A, Inserra C, Béra JC. Sonoporation of adherent cells under regulated ultrasound cavitation conditions. ULTRASOUND IN MEDICINE & BIOLOGY 2015; 41:1008-1019. [PMID: 25701522 DOI: 10.1016/j.ultrasmedbio.2014.11.001] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/04/2014] [Revised: 09/08/2014] [Accepted: 11/06/2014] [Indexed: 06/04/2023]
Abstract
A sonoporation device dedicated to the adherent cell monolayer has been implemented with a regulation process allowing the real-time monitoring and control of inertial cavitation activity. Use of the cavitation-regulated device revealed first that adherent cell sonoporation efficiency is related to inertial cavitation activity, without inducing additional cell mortality. Reproducibility is enhanced for the highest sonoporation rates (up to 17%); sonoporation efficiency can reach 26% when advantage is taken of the standing wave acoustic configuration by applying a frequency sweep with ultrasound frequency tuned to the modal acoustic modes of the cavity. This device allows sonoporation of adherent and suspended cells, and the use of regulation allows some environmental parameters such as the temperature of the medium to be overcome, resulting in the possibility of cell sonoporation even at ambient temperature.
Collapse
Affiliation(s)
- Pauline Muleki Seya
- Inserm, U1032, LabTau, Lyon, F-69003, France; Université de Lyon, Lyon, F-69003, France.
| | - Manuela Fouqueray
- Inserm, U1032, LabTau, Lyon, F-69003, France; Université de Lyon, Lyon, F-69003, France
| | - Jacqueline Ngo
- Inserm, U1032, LabTau, Lyon, F-69003, France; Université de Lyon, Lyon, F-69003, France
| | - Adrien Poizat
- Inserm, U1032, LabTau, Lyon, F-69003, France; Université de Lyon, Lyon, F-69003, France
| | - Claude Inserra
- Inserm, U1032, LabTau, Lyon, F-69003, France; Université de Lyon, Lyon, F-69003, France
| | - Jean-Christophe Béra
- Inserm, U1032, LabTau, Lyon, F-69003, France; Université de Lyon, Lyon, F-69003, France
| |
Collapse
|
42
|
Chong ZZ, Tor SB, Loh NH, Wong TN, Gañán-Calvo AM, Tan SH, Nguyen NT. Acoustofluidic control of bubble size in microfluidic flow-focusing configuration. LAB ON A CHIP 2015; 15:996-999. [PMID: 25510843 DOI: 10.1039/c4lc01139b] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
This paper reports a method to control the bubble size generated in a microfluidic flow-focusing configuration. With an ultrasonic transducer, we induce acoustic streaming using a forward moving, oscillating gas-liquid interface. The induced streaming substantially affects the formation process of gas bubbles. The oscillating interface acts as a pump that increases the gas flow rate significantly and forms a larger bubble. This method is applicable to a wide range of gas pressure from 30 to 90 kPa and flow rate from 380 to 2700 μL h(-1). The bubble size can be tuned repeatedly with the response time on the order of seconds. We believe that this method will enhance the capability of a microfluidic bubble generator to produce a tunable bubble size.
Collapse
Affiliation(s)
- Zhuang Zhi Chong
- School of Mechanical and Aerospace Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore 639798.
| | | | | | | | | | | | | |
Collapse
|
43
|
Fan Q, Hu W, Ohta AT. Efficient single-cell poration by microsecond laser pulses. LAB ON A CHIP 2015; 15:581-8. [PMID: 25421758 PMCID: PMC4304703 DOI: 10.1039/c4lc00943f] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
Payloads including FITC-Dextran dye and plasmids were delivered into NIH/3T3 fibroblasts using microbubbles produced by microsecond laser pulses to induce pores in the cell membranes. Two different operational modes were used to achieve molecular delivery. Smaller molecules, such as the FITC-Dextran dye, were delivered via a scanning-laser mode. The poration efficiency and the cell viability were both 95.1 ± 3.0%. Relatively larger GFP plasmids can be delivered efficiently via a fixed-laser mode, which is a more vigorous method that can create larger transient pores in the cell membrane. The transfection efficiency of 5.7 kb GFP plasmid DNA can reach to 86.7 ± 3.3%. Using this cell poration system, targeted single cells can be porated with high resolution, and cells can be porated in arbitrary patterns.
Collapse
Affiliation(s)
- Qihui Fan
- Department of Mechanical Engineering, University of Hawaii at Manoa, 2540 Dole Street, Holmes Hall 302, Honolulu, USA., Fax: +1-808-956-3427; Tel: 808-956-3427
| | - Wenqi Hu
- Department of Electrical Engineering, University of Hawaii at Manoa, 2540 Dole Street, Holmes Hall 483, Honolulu, USA
| | - Aaron T. Ohta
- Department of Electrical Engineering, University of Hawaii at Manoa, 2540 Dole Street, Holmes Hall 483, Honolulu, USA
| |
Collapse
|
44
|
Tzu-Yin W, Wilson KE, Machtaler S, Willmann JK. Ultrasound and microbubble guided drug delivery: mechanistic understanding and clinical implications. Curr Pharm Biotechnol 2014; 14:743-52. [PMID: 24372231 DOI: 10.2174/1389201014666131226114611] [Citation(s) in RCA: 80] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2013] [Revised: 10/03/2013] [Accepted: 10/03/2013] [Indexed: 12/11/2022]
Abstract
Ultrasound mediated drug delivery using microbubbles is a safe and noninvasive approach for spatially localized drug administration. This approach can create temporary and reversible openings on cellular membranes and vessel walls (a process called "sonoporation"), allowing for enhanced transport of therapeutic agents across these natural barriers. It is generally believed that the sonoporation process is highly associated with the energetic cavitation activities (volumetric expansion, contraction, fragmentation, and collapse) of the microbubble. However, a thorough understanding of the process was unavailable until recently. Important progress on the mechanistic understanding of sonoporation and the corresponding physiological responses in vitro and in vivo has been made. Specifically, recent research shed light on the cavitation process of microbubbles and fluid motion during insonation of ultrasound, on the spatio-temporal interactions between microbubbles and cells or vessel walls, as well as on the temporal course of the subsequent biological effects. These findings have significant clinical implications on the development of optimal treatment strategies for effective drug delivery. In this article, current progress in the mechanistic understanding of ultrasound and microbubble mediated drug delivery and its implications for clinical translation is discussed.
Collapse
Affiliation(s)
| | | | | | - Jurgen K Willmann
- Department of Radiology and Molecular Imaging Program at Stanford, School of Medicine, Stanford University, 300 Pasteur Drive, Room H1307, Stanford, CA 94305-5621, USA.
| |
Collapse
|
45
|
Fast temperature measurement following single laser-induced cavitation inside a microfluidic gap. Sci Rep 2014; 4:5445. [PMID: 24962341 PMCID: PMC4069706 DOI: 10.1038/srep05445] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2014] [Accepted: 06/06/2014] [Indexed: 11/21/2022] Open
Abstract
Single transient laser-induced microbubbles have been used in microfluidic chips for fast actuation of the liquid (pumping and mixing), to interact with biological materials (selective cell destruction, membrane permeabilization and rheology) and more recenty for medical diagnosis. However, the expected heating following the collapse of a microbubble (maximum radius ~ 10–35 µm) has not been measured due to insufficient temporal resolution. Here, we extend the limits of non-invasive fluorescence thermometry using high speed video recording at up to 90,000 frames per second to measure the evolution of the spatial temperature profile imaged with a fluorescence microscope. We found that the temperature rises are moderate (< 12.8°C), localized (< 15 µm) and short lived (< 1.3 ms). However, there are significant differences between experiments done in a microfluidic gap and a container unbounded at the top, which are explained by jetting and bubble migration. The results allow to safe-guard some of the current applications involving laser pulses and photothermal bubbles interacting with biological material in different liquid environments.
Collapse
|
46
|
Chen Y, Lee S. Manipulation of Biological Objects Using Acoustic Bubbles: A Review. Integr Comp Biol 2014; 54:959-68. [DOI: 10.1093/icb/icu091] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023] Open
|
47
|
Fan Q, Hu W, Ohta AT. Laser-induced microbubble poration of localized single cells. LAB ON A CHIP 2014; 14:1572-8. [PMID: 24632785 PMCID: PMC4004443 DOI: 10.1039/c3lc51394g] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
Laser-induced microbubbles were used to porate the cell membranes of localized single NIH/3T3 fibroblasts. Microsecond laser pulses were focused on an optically absorbent substrate, creating a vapour microbubble that oscillated in size at the laser focal point in a fluidic chamber. The shear stress accompanying the bubble size oscillation was able to porate nearby cells. Cell poration was demonstrated with the delivery of FITC-dextran dye with various molecular weights. Under optimal poration conditions, the cell poration efficiency was up to 95.2 ± 4.8%, while maintaining 97.6 ± 2.4% cell viability. The poration system is able to target a single cell without disturbing surrounding cells.
Collapse
Affiliation(s)
- Qihui Fan
- Department of Mechanical Engineering, University of Hawaii at Manoa, 2540 Dole Street, Holmes Hall 302, Honolulu, USA. Fax: +1-808-956-3427; Tel: 808-956-3427
| | - Wenqi Hu
- Department of Electrical Engineering, University of Hawaii at Manoa, 2540 Dole Street, Holmes Hall 483, Honolulu, USA
| | - Aaron T. Ohta
- Department of Electrical Engineering, University of Hawaii at Manoa, 2540 Dole Street, Holmes Hall 483, Honolulu, USA
| |
Collapse
|
48
|
Unal M, Alapan Y, Jia H, Varga AG, Angelino K, Aslan M, Sayin I, Han C, Jiang Y, Zhang Z, Gurkan UA. Micro and Nano-Scale Technologies for Cell Mechanics. Nanobiomedicine (Rij) 2014; 1:5. [PMID: 30023016 PMCID: PMC6029242 DOI: 10.5772/59379] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2014] [Accepted: 09/18/2014] [Indexed: 01/09/2023] Open
Abstract
Cell mechanics is a multidisciplinary field that bridges cell biology, fundamental mechanics, and micro and nanotechnology, which synergize to help us better understand the intricacies and the complex nature of cells in their native environment. With recent advances in nanotechnology, microfabrication methods and micro-electro-mechanical-systems (MEMS), we are now well situated to tap into the complex micro world of cells. The field that brings biology and MEMS together is known as Biological MEMS (BioMEMS). BioMEMS take advantage of systematic design and fabrication methods to create platforms that allow us to study cells like never before. These new technologies have been rapidly advancing the study of cell mechanics. This review article provides a succinct overview of cell mechanics and comprehensively surveys micro and nano-scale technologies that have been specifically developed for and are relevant to the mechanics of cells. Here we focus on micro and nano-scale technologies, and their applications in biology and medicine, including imaging, single cell analysis, cancer cell mechanics, organ-on-a-chip systems, pathogen detection, implantable devices, neuroscience and neurophysiology. We also provide a perspective on the future directions and challenges of technologies that relate to the mechanics of cells.
Collapse
Affiliation(s)
- Mustafa Unal
- Department of Electrical Engineering and Computer Science, Case Western Reserve University, Cleveland, USA
| | - Yunus Alapan
- Department of Electrical Engineering and Computer Science, Case Western Reserve University, Cleveland, USA
- Case Biomanufacturing and Microfabrication Laboratory, Case Western Reserve University, Cleveland, USA
| | - Hao Jia
- Department of Biology, Case Western Reserve University, Cleveland, USA
| | - Adrienn G. Varga
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, USA
| | - Keith Angelino
- Department of Civil Engineering, Case Western Reserve University, Cleveland, USA
| | - Mahmut Aslan
- Department of Electrical Engineering and Computer Science, Case Western Reserve University, Cleveland, USA
- Case Biomanufacturing and Microfabrication Laboratory, Case Western Reserve University, Cleveland, USA
| | - Ismail Sayin
- Case Biomanufacturing and Microfabrication Laboratory, Case Western Reserve University, Cleveland, USA
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, USA
| | - Chanjuan Han
- Department of Mechanical and Aerospace Engineering, Case Western Reserve University, Cleveland, USA
| | - Yanxia Jiang
- Department of Electrical Engineering and Computer Science, Case Western Reserve University, Cleveland, USA
| | - Zhehao Zhang
- Department of Civil Engineering, Case Western Reserve University, Cleveland, USA
| | - Umut A. Gurkan
- Department of Electrical Engineering and Computer Science, Case Western Reserve University, Cleveland, USA
- Case Biomanufacturing and Microfabrication Laboratory, Case Western Reserve University, Cleveland, USA
- Department of Orthopaedics, Case Western Reserve University, Cleveland, USA
- Advanced Platform Technology Center, Louis Stokes Cleveland Veterans Affairs Medical Center, Cleveland, USA
| |
Collapse
|
49
|
Azam FI, Karri B, Ohl SW, Klaseboer E, Khoo BC. Dynamics of an oscillating bubble in a narrow gap. PHYSICAL REVIEW. E, STATISTICAL, NONLINEAR, AND SOFT MATTER PHYSICS 2013; 88:043006. [PMID: 24229275 DOI: 10.1103/physreve.88.043006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/02/2013] [Revised: 08/12/2013] [Indexed: 06/02/2023]
Abstract
The complex dynamics of a single bubble of a few millimeters in size oscillating inside a narrow fluid-filled gap between two parallel plates is studied using high-speed videography. Two synchronized high-speed cameras were used to observe both the side and front views of the bubble. The front-view images show bubble expansion and collapse with the formation of concentric dark and bright rings. The simultaneous recordings reveal the mechanism behind these rings. The side-view images reveal two different types of collapse behavior of the bubble including a previously unreported collapse phenomenon that is observed as the gap width is changed. At narrow widths, the bubble collapses towards the center of the gap; when the width is increased, the bubble splits before collapsing towards the walls. The bubble dynamics is also observed to be unaffected by the hydrophobic or hydrophilic nature of the plate surface due to the presence of a thin film of liquid between each of the plates and the bubble throughout the bubble lifetime. It is revealed that such systems do not behave as quasi-two-dimensional systems; three-dimensional effects are important.
Collapse
Affiliation(s)
- Fahad Ibn Azam
- Department of Mechanical Engineering, National University of Singapore, Kent Ridge, Singapore 119260
| | | | | | | | | |
Collapse
|
50
|
Li F, Chan C, Ohl C. Yield strength of human erythrocyte membranes to impulsive stretching. Biophys J 2013; 105:872-9. [PMID: 23972839 PMCID: PMC3752135 DOI: 10.1016/j.bpj.2013.06.045] [Citation(s) in RCA: 44] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2013] [Revised: 06/24/2013] [Accepted: 06/25/2013] [Indexed: 01/25/2023] Open
Abstract
Deformability while remaining viable is an important mechanical property of cells. Red blood cells (RBCs) deform considerably while flowing through small capillaries. The RBC membrane can withstand a finite strain, beyond which it ruptures. The classical yield areal strain of 2-4% for RBCs is generally accepted for a quasi-static strain. It has been noted previously that this threshold strain may be much larger with shorter exposure duration. Here we employ an impulse-like forcing to quantify this yield strain of RBC membranes. In the experiments, RBCs are stretched within tens of microseconds by a strong shear flow generated from a laser-induced cavitation bubble. The deformation of the cells in the strongly confined geometry is captured with a high-speed camera and viability is successively monitored with fluorescence microscopy. We find that the probability of cell survival is strongly dependent on the maximum strain. Above a critical areal strain of ∼40%, permanent membrane damage is observed for 50% of the cells. Interestingly, many of the cells do not rupture immediately and exhibit ghosting, but slowly obtain a round shape before they burst. This observation is explained with structural membrane damage leading to subnanometer-sized pores. The cells finally lyse from the colloidal osmotic pressure imbalance.
Collapse
Affiliation(s)
| | | | - Claus Dieter Ohl
- Division of Physics and Applied Physics, School of Physical and Mathematical Sciences, Nanyang Technological University, Singapore
| |
Collapse
|