1
|
Dwivedi S, Zehra F, Masih J, Gupta T, Lawrence A. Investigating the temporal dynamics of sub-micron particles and particle-bound transition metals in indoor air of a metropolitan city. ENVIRONMENTAL GEOCHEMISTRY AND HEALTH 2024; 46:49. [PMID: 38227135 DOI: 10.1007/s10653-023-01786-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/31/2023] [Accepted: 11/13/2023] [Indexed: 01/17/2024]
Abstract
The present study portrays an association between particle-bound transition metals and children's health. The indoor air quality of the urban metropolitan city households was monitored for four PM sizes, namely PM1.0-2.5, PM0.50-1.0, PM0.25-0.50 and PM<0.25, in major seasons observed in the city; summer and winter. Further transition/heavy metals, viz. Cr, Cu, Fe, Mn, Ni, Pb and Zn, were analysed in PM1-2.5 samples. In order to evaluate the effect, health risk assessment was performed using mathematical and computational model for assessing dermal exposure and dose estimation (multiple path particle dosimetry model version3.0). The study principally targeted the children aged 2-15 years for the health risk assessment. According to the results, for the largest particle size i.e. PM1.0-2.5 the highest deposition was in the head region (49.1%) followed by pulmonary (43.6%) and tracheobronchial region (7.2%), whereas, for the smallest particle size i.e. PM<0.25 the highest deposition was obtained in the pulmonary region (73.0%) followed by the head (13.6%) and TB region (13.2%). Also, the most imperilled group of children with highest dose accumulation was found to be children aged 8-9 years for all particle sizes. Moreover, the dermal exposure dose as evaluated was found to be preeminent for Ni, Zn and Pb. Besides, seasonal variation gesticulated towards elevated concentrations in winter relative to the summer season. Altogether, the study will provide a conception to the researchers in the fields mounting season-specific guidelines and mitigation approaches. Conclusively, the study commends future work focussing on defining the effects of other chemical components on particles and associated transition metal composition along with proper extenuation of the same.
Collapse
Affiliation(s)
- Samridhi Dwivedi
- Department of Chemistry, Isabella Thoburn College, Lucknow, India
| | - Farheen Zehra
- Department of Chemistry, Isabella Thoburn College, Lucknow, India
| | - Jamson Masih
- Department of Chemistry, Wilson College, Mumbai, India
| | - Tarun Gupta
- Department of Civil Engineering, Indian Institute of Technology, Kanpur, India
| | - Alfred Lawrence
- Department of Chemistry, Isabella Thoburn College, Lucknow, India.
| |
Collapse
|
2
|
Dacunto P, Nam S, Hirn M, Rodriguez A, Owkes M, Benson M. Classroom aerosol dispersion modeling: experimental assessment of a low-cost flow simulation tool. ENVIRONMENTAL SCIENCE. PROCESSES & IMPACTS 2023; 25:2157-2166. [PMID: 37966351 DOI: 10.1039/d3em00356f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2023]
Abstract
The purpose of this study was to assess the utility of a low-cost flow simulation tool for an indoor air modeling application by comparing its outputs with the results of a physical experiment, as well as those from a more advanced computational fluid dynamics (CFD) software package. Five aerosol dispersion tests were performed in two different classrooms by releasing a CO2 tracer gas from six student locations. Resultant steady-state concentrations were monitored at 13 locations around the periphery of the room. Subsequently, the experiments were modeled using both a low-cost tool (SolidWorks Flow Simulation) and a more sophisticated tool (STAR-CCM+). Models were evaluated based on their ability to predict the experimentally measured concentrations at the 13 monitoring locations by calculating four performance parameters commonly used in the evaluation of dispersion models: fractional mean bias (FB), normalized mean-square error (NMSE), fraction of predicted value within a factor of two (FAC2), and normalized absolute difference (NAD). The more sophisticated model performed better in 15 of the 20 possible cases (five tests at four parameters each), with parameters meeting acceptance criteria in 19 of 20 cases. However, the lower-cost tool was only slightly worse, with parameters meeting acceptance criteria in 18 of 20 cases, and it performed better than the other tool in 3 of 20 cases. Because it provides useful results at a fraction of the monetary and training cost and is already widely accessible to many institutions, such a tool may be worthwhile for many indoor aerosol dispersion applications, especially for students or researchers just beginning CFD modeling.
Collapse
Affiliation(s)
- P Dacunto
- United States Military Academy, Department of Geography and Environmental Engineering, West Point NY 10996, USA.
| | - S Nam
- United States Military Academy, Department of Geography and Environmental Engineering, West Point NY 10996, USA.
| | - M Hirn
- United States Military Academy, Department of Geography and Environmental Engineering, West Point NY 10996, USA.
| | - A Rodriguez
- United States Military Academy, Department of Civil and Mechanical Engineering, West Point NY 10996, USA
| | - M Owkes
- Montana State University, Department of Mechanical and Industrial Engineering, Bozeman MT 59717, USA
| | - M Benson
- United States Military Academy, Department of Civil and Mechanical Engineering, West Point NY 10996, USA
- Oak Ridge National Laboratory, Oak Ridge TN 37830, USA
| |
Collapse
|
3
|
González Serrano V, Lin EZ, Godri Pollitt KJ, Licina D. Adequacy of stationary measurements as proxies for residential personal exposure to gaseous and particle air pollutants. ENVIRONMENTAL RESEARCH 2023; 231:116197. [PMID: 37224948 DOI: 10.1016/j.envres.2023.116197] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/23/2023] [Revised: 05/15/2023] [Accepted: 05/17/2023] [Indexed: 05/26/2023]
Abstract
People are exposed to myriad of airborne pollutants in their homes. Owing to diverse potential sources of air pollution and human activity patterns, accurate assessment of residential exposures is complex. In this study, we explored the relationship between personal and stationary air pollutant measurements in residences of 37 participants working from home during the heating season. Stationary environmental monitors (SEMs) were located in the bedroom, living room or home office and personal exposure monitors (PEMs) were worn by the participants. SEMs and PEMs included both real-time sensors and passive samplers. During three consecutive weekdays, continuous data were obtained for particle number concentration (size range 0.3-10 μm), carbon dioxide (CO2), and total volatile organic compounds (TVOC), while passive samplers collected integrated measures of 36 volatile organic compounds (VOCs) and semi volatile organic compounds (SVOCs). The personal cloud effect was detected in >80% of the participants for CO2 and >50% participants for PM10. Multiple linear regression analysis showed that a single CO2 monitor placed in the bedroom efficiently represented personal exposure to CO2 (R2 = 0.90) and moderately so for PM10 (R2 = 0.55). Adding a second or third sensor in a residence did not lead to improved exposure estimates for CO2, with only 6-9% improvement for particles. Selecting data from SEMs when participants were in the same room improved personal exposure estimates by 33% for CO2 and 5% for particles. Out of 36 detected VOCs and SVOCs, 13 had at least 50% higher concentrations in personal versus stationary samples. Findings from this study aid improved understanding of the complex dynamics of gaseous and particle pollutants and their sources in residences, and could support the development of refined procedures for residential air quality monitoring and inhalation exposure assessment.
Collapse
Affiliation(s)
- Viviana González Serrano
- Human-Oriented Built Environment Lab, School of Architecture, Civil and Environmental Engineering, École Polytechnique Fédérale de Lausanne (EPFL), Switzerland
| | - Elizabeth Z Lin
- Environmental Health Sciences Department, School of Public Health, Yale University, New Haven, USA
| | - Krystal J Godri Pollitt
- Environmental Health Sciences Department, School of Public Health, Yale University, New Haven, USA
| | - Dusan Licina
- Human-Oriented Built Environment Lab, School of Architecture, Civil and Environmental Engineering, École Polytechnique Fédérale de Lausanne (EPFL), Switzerland.
| |
Collapse
|
4
|
Schimmoller BJ, Trovão NS, Isbell M, Goel C, Heck BF, Archer TC, Cardinal KD, Naik NB, Dutta S, Rohr Daniel A, Beheshti A. COVID-19 Exposure Assessment Tool (CEAT): Exposure quantification based on ventilation, infection prevalence, group characteristics, and behavior. SCIENCE ADVANCES 2022; 8:eabq0593. [PMID: 36179034 PMCID: PMC9524836 DOI: 10.1126/sciadv.abq0593] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/15/2022] [Accepted: 08/17/2022] [Indexed: 06/16/2023]
Abstract
The coronavirus disease 2019 (COVID-19) Exposure Assessment Tool (CEAT) allows users to compare respiratory relative risk to severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) for various scenarios, providing understanding of how combinations of protective measures affect risk. CEAT incorporates mechanistic, stochastic, and epidemiological factors including the (i) emission rate of virus, (ii) viral aerosol degradation and removal, (iii) duration of activity/exposure, (iv) inhalation rates, (v) ventilation rates (indoors/outdoors), (vi) volume of indoor space, (vii) filtration, (viii) mask use and effectiveness, (ix) distance between people (taking into account both near-field and far-field effects of proximity), (x) group size, (xi) current infection rates by variant, (xii) prevalence of infection and immunity in the community, (xiii) vaccination rates, and (xiv) implementation of COVID-19 testing procedures. CEAT applied to published studies of COVID-19 transmission events demonstrates the model's accuracy. We also show how health and safety professionals at NASA Ames Research Center used CEAT to manage potential risks posed by SARS-CoV-2 exposures.
Collapse
Affiliation(s)
- Brian J. Schimmoller
- Signature Science LLC, Austin, TX 78759, USA
- COVID-19 International Research Team, Medford, MA 02155, USA
| | - Nídia S. Trovão
- COVID-19 International Research Team, Medford, MA 02155, USA
- Fogarty International Center, National Institutes of Health, Bethesda, MD 20892, USA
| | | | - Chirag Goel
- COVID-19 International Research Team, Medford, MA 02155, USA
- Northwestern University Feinberg School of Medicine, Chicago, IL 60611, USA
| | - Benjamin F. Heck
- Bastion Technologies, NASA Ames Research Center, Moffett Field, CA 94035, USA
| | - Tenley C. Archer
- COVID-19 International Research Team, Medford, MA 02155, USA
- Biomea Fusion Inc., Redwood City, CA 94063, USA
| | - Klint D. Cardinal
- Leidos Inc., NASA Ames Research Center, Moffett Field, CA 94035, USA
| | - Neil B. Naik
- Leidos Inc., NASA Ames Research Center, Moffett Field, CA 94035, USA
| | - Som Dutta
- COVID-19 International Research Team, Medford, MA 02155, USA
- Mechanical and Aerospace Engineering, Utah State University, Logan, UT 84332, USA
| | - Ahleah Rohr Daniel
- Space Biosciences Division, NASA Ames Research Center, Moffett Field, CA 94035, USA
| | - Afshin Beheshti
- COVID-19 International Research Team, Medford, MA 02155, USA
- KBR, Space Biosciences Division, NASA Ames Research Center, Moffett Field, CA 94035, USA
- Stanley Center for Psychiatric Research, Broad Institute of MIT and Harvard, Cambridge, MA 02142, USA
| |
Collapse
|
5
|
Dacunto P, Ng A, Moser D, Tovkach A, Scanlon S, Benson M. Effects of location, classroom orientation, and air change rate on potential aerosol exposure: an experimental and computational study. ENVIRONMENTAL SCIENCE. PROCESSES & IMPACTS 2022; 24:557-566. [PMID: 35244126 DOI: 10.1039/d1em00434d] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
This study examined the dispersion of potentially infectious aerosols in classrooms by means of both a CO2 tracer gas, and multizone contaminant transport modeling. A total of 20 tests were conducted in three different university classrooms at multiple air change rates (4.4-9.7/h), each with two different room orientations: one with the tracer gas released from six student desks toward the air return, and one with the same tracer gas released away from it. Resulting tracer concentrations were measured by 19 different monitors arrayed throughout the room. Steady-state, mean tracer gas concentrations were calculated in six instructor zones (A-F) around the periphery of the room, with the results normalized by the concentration at the return, which was assumed to be representative of the well-mixed volume of the room. Across all classrooms, zones farthest from the return (C, D) had the lowest mean normalized concentrations (0.75), while those closest to the return (A, F) had the highest (0.95). This effect was consistent across room orientations (release both toward and away from the return), and air change rates. In addition, all zones around the periphery of the room had a significantly lower concentration than those adjacent to the sources. Increasing the ventilation rate reduced tracer gas concentrations significantly. Similar trends were observed via a novel approach to CONTAM modeling of the same rooms. These results indicate that informed selection of teaching location within the classroom could reduce instructor exposure.
Collapse
Affiliation(s)
- P Dacunto
- United States Military Academy, Department of Geography and Environmental Engineering, West Point, NY 10996, USA.
| | - A Ng
- United States Military Academy, Department of Geography and Environmental Engineering, West Point, NY 10996, USA.
| | - D Moser
- United States Military Academy, Department of Civil and Mechanical Engineering, West Point, NY 10996, USA
| | - A Tovkach
- United States Military Academy, Department of Geography and Environmental Engineering, West Point, NY 10996, USA.
| | - S Scanlon
- United States Military Academy, Department of Civil and Mechanical Engineering, West Point, NY 10996, USA
| | - M Benson
- United States Military Academy, Department of Civil and Mechanical Engineering, West Point, NY 10996, USA
| |
Collapse
|
6
|
Schimmoller BJ, Trovão NS, Isbell M, Goel C, Heck BF, Archer TC, Cardinal KD, Naik NB, Dutta S, Daniel AR, Beheshti A. Covid-19 Exposure Assessment Tool (CEAT): Easy-to-use tool to quantify exposure based on airflow, group behavior, and infection prevalence in the community. MEDRXIV : THE PREPRINT SERVER FOR HEALTH SCIENCES 2022:2022.03.02.22271806. [PMID: 35291295 PMCID: PMC8923112 DOI: 10.1101/2022.03.02.22271806] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
Abstract
The COVID-19 Exposure Assessment Tool (CEAT) allows users to compare respiratory relative risk to SARS-CoV-2 for various scenarios, providing understanding of how combinations of protective measures affect exposure, dose, and risk. CEAT incorporates mechanistic, stochastic and epidemiological factors including the: 1) emission rate of virus, 2) viral aerosol degradation and removal, 3) duration of activity/exposure, 4) inhalation rates, 5) ventilation rates (indoors/outdoors), 6) volume of indoor space, 7) filtration, 8) mask use and effectiveness, 9) distance between people, 10) group size, 11) current infection rates by variant, 12) prevalence of infection and immunity in the community, 13) vaccination rates of the community, and 14) implementation of COVID-19 testing procedures. Demonstration of CEAT, from published studies of COVID-19 transmission events, shows the model accurately predicts transmission. We also show how health and safety professionals at NASA Ames Research Center used CEAT to manage potential risks posed by SARS-CoV-2 exposures. Given its accuracy and flexibility, the wide use of CEAT will have a long lasting beneficial impact in managing both the current COVID-19 pandemic as well as a variety of other scenarios.
Collapse
Affiliation(s)
- Brian J. Schimmoller
- Signature Science LLC, Austin, TX, 78759, USA
- COVID-19 International Research Team
- Lead Contacts
| | - Nídia S. Trovão
- COVID-19 International Research Team
- Fogarty International Center, National Institutes of Health, Bethesda, Maryland, USA
| | | | - Chirag Goel
- COVID-19 International Research Team
- Northwestern University Feinberg School of Medicine, Chicago, IL, 60611, USA
| | - Benjamin F. Heck
- Bastion Technologies, NASA Ames Research Center, Moffett Field, CA, 94035, USA
| | - Tenley C. Archer
- COVID-19 International Research Team
- Biomea Fusion, Inc. Redwood City, CA, 94063, USA
| | - Klint D. Cardinal
- Leidos, Inc., NASA Ames Research Center, Moffett Field, CA, 94035, USA
| | - Neil B. Naik
- Leidos, Inc., NASA Ames Research Center, Moffett Field, CA, 94035, USA
| | - Som Dutta
- COVID-19 International Research Team
- Mechanical & Aerospace Engineering, Utah State University, Logan, UT 84332, USA
| | - Ahleah Rohr Daniel
- Space Biosciences Division, NASA Ames Research Center, Moffett Field, CA, 94035, USA
| | - Afshin Beheshti
- COVID-19 International Research Team
- KBR, Space Biosciences Division, NASA Ames Research Center, Moffett Field, CA, 94035, USA
- Stanley Center for Psychiatric Research, Broad Institute of MIT and Harvard, Cambridge, MA, 02142, USA
- Lead Contacts
| |
Collapse
|
7
|
González Serrano V, Licina D. Longitudinal assessment of personal air pollution clouds in ten home and office environments. INDOOR AIR 2022; 32:e12993. [PMID: 35225383 DOI: 10.1111/ina.12993] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/08/2021] [Revised: 12/22/2021] [Accepted: 01/20/2022] [Indexed: 06/14/2023]
Abstract
Elevated exposure to indoor air pollution is associated with negative human health and well-being outcomes. Inhalation exposure studies commonly rely on stationary monitors in combination with human time-activity patterns; however, this method is susceptible to exposure misclassification. We tracked ten participants during five consecutive workdays with stationary air pollutant monitors at their homes and offices, and wearable personal monitors. Real-time measures of size-resolved particulate matter (within range 0.3-10 μm) and CO2 , and integrated samples of PM10 , VOCs, and aldehydes were collected. The PM10 cloud magnitude (excess of PM10 beyond stationary room concentration) was detected for all participants in homes and offices. The PM10 cloud magnitude ranged within 5-37 μg/m3 and was the most discernible in the coarse particle size fraction. Particles associated with "Urban mix," "Traffic," and "Human activities" sources contributed the most to PM10 exposures. The personal CO2 clouds were detected for participants with the SEMs in their living rooms and private or low-occupancy offices. The stationary monitors placed in bedrooms were better predictors of personal PM10 and CO2 exposures. An overall of 33 VOCs and aldehydes were detected in both microenvironments, with the majority exhibiting high correlation between personal and stationary stations.
Collapse
Affiliation(s)
- Viviana González Serrano
- Human-Oriented Built Environment Lab, School of Architecture, Civil and Environmental Engineering, École Polytechnique Fédérale de Lausanne, Lausanne, Switzerland
| | - Dusan Licina
- Human-Oriented Built Environment Lab, School of Architecture, Civil and Environmental Engineering, École Polytechnique Fédérale de Lausanne, Lausanne, Switzerland
| |
Collapse
|
8
|
Cheng KC, Ott W, Wallace L, Zhu Y, Hildemann L. PM 2.5 exposure close to marijuana smoking and vaping: A case study in residential indoor and outdoor settings. THE SCIENCE OF THE TOTAL ENVIRONMENT 2022; 802:149897. [PMID: 34464798 DOI: 10.1016/j.scitotenv.2021.149897] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/09/2021] [Revised: 08/21/2021] [Accepted: 08/21/2021] [Indexed: 06/13/2023]
Abstract
We conducted 35 experiments for spatial measurement of marijuana aerosols in a current smoker's residential spaces. Fine particulate matter (PM2.5) concentrations were measured every second at 1, 2, and 3 m horizontal distances from the smoker who performed prescribed 5-min smoking and vaping activities. In each experiment, five SidePak monitors measured PM2.5 concentrations at five different angles facing the front of the smoker, representing the worst-case exposures. We studied the effect of distance from the smoker for two marijuana sources - smoking a marijuana cigarette, or joint, and vaping a liquid-cartridge vaping pen. Experiments were conducted in the family room indoors and in the backyard outdoors where the smoker normally consumes marijuana. Indoor marijuana vaping had higher average exposures (5-min PM2.5) at 1 m distance than indoor marijuana smoking, but the levels from indoor vaping decreased more rapidly with distance (e.g., 77% reduction for vaping versus 33% for smoking from 1 to 2 m). Smoking and vaping in the outdoor environment reduce the average exposures down to <5% of the indoor levels at each distance. Cumulative frequency distributions of the 1-s PM2.5 concentrations revealed the frequencies of exceeding any selected transient peak exposure limit at a given distance. The frequency of exceedance decreased more quickly with distance for vaping than for smoking. Smoking and vaping outdoors made the transient peak exposures close to the source much less frequent than smoking and vaping indoors (e.g., <1% exceeded 1000 μg/m3 outdoors versus >20% indoors at 1 m). Plotting the frequency of exceedance versus distance could offer additional guidance for a recommended minimum distance from a marijuana source.
Collapse
Affiliation(s)
- Kai-Chung Cheng
- Civil and Environmental Engineering Department, Stanford University, MS 4020, Stanford, CA 94305-4020, United States of America.
| | - Wayne Ott
- 1008 Cardiff Lane, Redwood City, CA 94061, United States of America
| | - Lance Wallace
- 428 Woodley Way, Santa Rosa, CA 95409, United States of America
| | - Yifang Zhu
- UCLA Fielding School of Public Health, 650 Charles E. Young Drive South, 51-295B CHS, Los Angeles, CA 90095, United States of America
| | - Lynn Hildemann
- Civil and Environmental Engineering Department, Stanford University, MS 4020, Stanford, CA 94305-4020, United States of America
| |
Collapse
|
9
|
Dacunto P, Moser D, Ng A, Benson M. Classroom aerosol dispersion: desk spacing and divider impacts. INTERNATIONAL JOURNAL OF ENVIRONMENTAL SCIENCE AND TECHNOLOGY : IJEST 2021; 19:1057-1070. [PMID: 34345237 PMCID: PMC8323540 DOI: 10.1007/s13762-021-03564-z] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/29/2020] [Revised: 05/05/2021] [Accepted: 07/18/2021] [Indexed: 06/13/2023]
Abstract
A study of aerosol dispersion was conducted in a university classroom using a CO2 tracer gas emitted from three source locations in a steady release, one source location per test. The tracer gas emitted from the single source location represented the potentially infectious aerosol droplets emitted from a single student and was thus a way to examine the influence of one sick student on the rest of the class. Two parameters were adjusted during the testing-the spacing of the desks, which included a spread and compressed configuration, and the inclusion of three-sided clear dividers attached to the student desk surfaces. Tracer dispersion was measured through the use of monitors in 13 locations within the classroom, with eight monitors representing seated student locations, four monitors representing a standing instructor along the classroom front, and one monitor at the return vent in the ceiling. As expected, spacing strongly influenced concentration levels at desks adjacent to the source location. The use of dividers reduced overall student and instructor location tracer concentrations when compared to desks without dividers in most cases. Finally, the influence of air change differences on the results was noted with consistent trends. The experimental construct provides a systematic means for classroom testing that may be broadly applicable to various configurations of classrooms beyond the one tested.
Collapse
Affiliation(s)
- P. Dacunto
- Department of Geography and Environmental Engineering, United States Military Academy, 745 Brewerton Road, West Point, NY 10996 USA
| | - D. Moser
- Department of Civil and Mechanical Engineering, United States Military Academy, West Point, NY 10996 USA
| | - A. Ng
- Department of Geography and Environmental Engineering, United States Military Academy, 745 Brewerton Road, West Point, NY 10996 USA
| | - M. Benson
- Department of Civil and Mechanical Engineering, United States Military Academy, West Point, NY 10996 USA
| |
Collapse
|
10
|
Lunderberg DM, Misztal PK, Liu Y, Arata C, Tian Y, Kristensen K, Weber RJ, Nazaroff WW, Goldstein AH. High-Resolution Exposure Assessment for Volatile Organic Compounds in Two California Residences. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2021; 55:6740-6751. [PMID: 33945266 DOI: 10.1021/acs.est.0c08304] [Citation(s) in RCA: 21] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Time spent in residences substantially contributes to human exposure to volatile organic compounds (VOCs). Such exposures have been difficult to study deeply, in part because VOC concentrations and indoor occupancy vary rapidly. Using a fast-response online mass spectrometer, we report time-resolved exposures from multi-season sampling of more than 200 VOCs in two California residences. Chemical-specific source apportionment revealed that time-averaged exposures for most VOCs were mainly attributable to continuous indoor emissions from buildings and their static contents. Also contributing to exposures were occupant-related activities, such as cooking, and outdoor-to-indoor transport. Health risk assessments are possible for a subset of observed VOCs. Acrolein, acetaldehyde, and acrylic acid concentrations were above chronic advisory health guidelines, whereas exposures for other assessable species were typically well below the guideline levels. Studied residences were built in the mid-20th century, indicating that VOC emissions even from older buildings and their contents can substantially contribute to occupant exposures.
Collapse
Affiliation(s)
- David M Lunderberg
- Department of Chemistry, University of California Berkeley, Berkeley, California 94720, United States
- Department of Environmental Science, Policy, and Management, University of California Berkeley, Berkeley, California 94720, United States
| | - Pawel K Misztal
- Department of Environmental Science, Policy, and Management, University of California Berkeley, Berkeley, California 94720, United States
| | - Yingjun Liu
- Department of Environmental Science, Policy, and Management, University of California Berkeley, Berkeley, California 94720, United States
| | - Caleb Arata
- Department of Chemistry, University of California Berkeley, Berkeley, California 94720, United States
- Department of Environmental Science, Policy, and Management, University of California Berkeley, Berkeley, California 94720, United States
| | - Yilin Tian
- Department of Environmental Science, Policy, and Management, University of California Berkeley, Berkeley, California 94720, United States
- Department of Civil and Environmental Engineering, University of California Berkeley, Berkeley, California 94720, United States
| | - Kasper Kristensen
- Department of Environmental Science, Policy, and Management, University of California Berkeley, Berkeley, California 94720, United States
| | - Robert J Weber
- Department of Environmental Science, Policy, and Management, University of California Berkeley, Berkeley, California 94720, United States
| | - William W Nazaroff
- Department of Civil and Environmental Engineering, University of California Berkeley, Berkeley, California 94720, United States
| | - Allen H Goldstein
- Department of Environmental Science, Policy, and Management, University of California Berkeley, Berkeley, California 94720, United States
- Department of Civil and Environmental Engineering, University of California Berkeley, Berkeley, California 94720, United States
| |
Collapse
|
11
|
Benjamin ML, Arnold S, Rao M, Davis K, Maier A, Virkutyte J. Ventilation and posture effects on inhalation exposures to volatile cleaning ingredients in a simulated domestic worker cleaning environment. INDOOR AIR 2021; 31:128-140. [PMID: 32648981 DOI: 10.1111/ina.12715] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/16/2019] [Revised: 05/13/2020] [Accepted: 07/06/2020] [Indexed: 06/11/2023]
Abstract
Associations between cleaning chemical exposures and asthma have previously been identified in professional cleaners and healthcare workers. Domestic workers, including housecleaners and caregivers, may receive similar exposures but in residential environments with lower ventilation rates. Study objectives were to compare exposures to occupational exposure limits (OELs), to determine relative contributions from individual cleaning tasks to overall exposure, and to evaluate the effects of ventilation and posture on exposure. Airborne chemical concentrations of sprayed cleaning chemicals (acetic acid or ammonia) were measured during typical cleaning tasks in a simulated residential work environment. Whole-house cleaning exposures (18 cleaning tasks) were measured using integrated personal sampling methods. Individual task exposures were measured with a sampling line attached to subjects' breathing zones, with readings recorded by a ppbRAE monitor, equipped with a photoionization detector calibrated for ammonia and acetic acid measurements. Integrated sampling results indicated no exposures above OELs occurred, but 95th percentile air concentrations would require risk management decisions. Exposure reductions were observed with increased source distance, with lower exposures from mopping floors compared to kneeling. Exposure reductions were also observed for most but not all tasks when ventilation was used, with implications that alternative exposure reduction methods may be needed.
Collapse
Affiliation(s)
- Michael L Benjamin
- Department of Environmental Health, University of Cincinnati College of Medicine, Cincinnati, OH, USA
| | - Susan Arnold
- Division of Environmental Health Sciences, School of Public Health, University of Minnesota, Minneapolis, MN, USA
| | - Marepalli Rao
- Department of Environmental Health, University of Cincinnati College of Medicine, Cincinnati, OH, USA
| | - Kermit Davis
- Department of Environmental Health, University of Cincinnati College of Medicine, Cincinnati, OH, USA
| | | | - Jurate Virkutyte
- Department of Environmental Health, University of Cincinnati College of Medicine, Cincinnati, OH, USA
| |
Collapse
|
12
|
Chung WC, Mei DH, Tu X, Chang MB. Removal of VOCs from gas streams via plasma and catalysis. CATALYSIS REVIEWS-SCIENCE AND ENGINEERING 2018. [DOI: 10.1080/01614940.2018.1541814] [Citation(s) in RCA: 53] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Affiliation(s)
- Wei-Chieh Chung
- Graduate Institute of Environmental Engineering, National Central University, Taoyuan City, Taiwan
| | - Dan-Hua Mei
- Department of Electrical Engineering and Electronics, University of Liverpool, Liverpool, UK
- College of Electrical Engineering and Control Science, Nanjing Tech Technology, Nanjing, People’s Republic of China
| | - Xin Tu
- Department of Electrical Engineering and Electronics, University of Liverpool, Liverpool, UK
| | - Moo-Been Chang
- Graduate Institute of Environmental Engineering, National Central University, Taoyuan City, Taiwan
| |
Collapse
|
13
|
Jayjock M, Havics AA. Residential inter-zonal ventilation rates for exposure modeling. JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE 2018; 15:376-388. [PMID: 29420141 DOI: 10.1080/15459624.2018.1438615] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
Residential inter-zonal (e.g., between rooms) ventilation is comprised of fresh air infiltration in and exfiltration out of the whole house plus the "fresh" air that is entering (and exiting) the room of interest from other rooms or areas within the house. Clearly, the inter-zone ventilation rate in any room of interest will be greater than the infiltration/exfiltration ventilation rate of outdoor air for the whole house. The purpose of this study is to determine how much greater the inter-zonal ventilation rate is in typical U.S. residences compared to the whole house ventilation rate from outdoor air. The data for this statistical analysis came from HouseDB, a 1995 EPA database of residential ventilation rates. Analytical results indicate that a lognormal distribution provides the best fit to the data. Lognormal probability distribution functions (PDFs) are provided for various inter-zonal ventilation rates for comparison to the PDF for the whole house ventilation rates. All ventilation rates are expressed as air change rates per hour (ACH). These PDFs can be used as inputs to exposure models. This analysis suggests that if one were performing a deterministic analysis for unknown housing stocks in the U.S., a default mean and median ACH values of 0.4/hr and 0.3/hr, respectively, for whole house ventilation would be appropriate; and 0.7/hr and 0.6/hr, respectively, for inter-zonal ventilation.
Collapse
|
14
|
Galatsis K. Engineering evidence for carbon monoxide toxicity cases. MEDICINE, SCIENCE, AND THE LAW 2016; 56:184-189. [PMID: 26137848 DOI: 10.1177/0025802415590174] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
Unintentional carbon monoxide poisonings and fatalities lead to many toxicity cases. Given the unusual physical properties of carbon monoxide-in that the gas is odorless and invisible-unorganized and erroneous methods in obtaining engineering evidence as required during the discovery process often occurs. Such evidence gathering spans domains that include building construction, appliance installation, industrial hygiene, mechanical engineering, combustion and physics. In this paper, we attempt to place a systematic framework that is relevant to key aspects in engineering evidence gathering for unintentional carbon monoxide poisoning cases. Such a framework aims to increase awareness of this process and relevant issues to help guide legal counsel and expert witnesses.
Collapse
Affiliation(s)
- Kosmas Galatsis
- Material Science and Engineering Department, School of Engineering and Applied Science, University of California, Los Angeles (UCLA), CA, USA
| |
Collapse
|
15
|
Coker ES, Smit E, Harding AK, Molitor J, Kile ML. A cross sectional analysis of behaviors related to operating gas stoves and pneumonia in U.S. children under the age of 5. BMC Public Health 2015; 15:77. [PMID: 25648867 PMCID: PMC4321321 DOI: 10.1186/s12889-015-1425-y] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2014] [Accepted: 01/15/2015] [Indexed: 01/31/2023] Open
Abstract
Background Poorly ventilated combustion stoves and pollutants emitted from combustion stoves increase the risk of acute lower respiratory illnesses (ALRI) in children living in developing countries but few studies have examined these issues in developed countries. Our objective is to investigate behaviors related to gas stove use, namely using them for heat and without ventilation, on the odds of pneumonia and cough in U.S. children. Methods The National Health and Nutrition Examination Survey (1988–1994) was used to identify children < 5 years who lived in homes with a gas stove and whose parents provided information on their behaviors when operating their gas stoves and data on pneumonia (N = 3,289) and cough (N = 3,127). Multivariate logistic regression models were used to examine the association between each respiratory outcome and using a gas stove for heat or without ventilation, as well as, the joint effect of both behaviors. Results The adjusted odds of parental-reported pneumonia (adjusted odds ratio [aOR] = 2.08, 95% confidence interval [CI]: 1.08, 4.03) and cough (aOR = 1.66, 95% CI: 1.14, 2.43) were higher among children who lived in homes where gas stoves were used for heat compared to those who lived in homes where gas stoves were only used for cooking. The odds of pneumonia (aOR = 1.76, 95% CI: 1.04, 2.98), but not cough (aOR = 1.23, 95% CI: 0.87, 1.75), was higher among those children whose parents did not report using ventilation when operating gas stoves compared to those who did use ventilation. When considering the joint association of both stove operating conditions, only children whose parents reported using gas stoves for heat without ventilation had significantly higher odds of pneumonia (aOR = 3.06, 95% CI: 1.32, 7.09) and coughing (aOR = 2.07, 95% CI: 1.29, 3.30) after adjusting for other risk factors. Conclusions Using gas stoves for heat without ventilation was associated with higher odds of pneumonia and cough among U.S. children less than five years old who live in homes with a gas stove. More research is needed to determine if emissions from gas stoves ventilation infrastructure, or modifiable behaviors contribute to respiratory infections in children.
Collapse
Affiliation(s)
- Eric S Coker
- College of Public Health and Human Sciences, Oregon State University, Milam Hall, Corvallis, OR, 97331, USA.
| | - Ellen Smit
- College of Public Health and Human Sciences, Oregon State University, Milam Hall, Corvallis, OR, 97331, USA.
| | - Anna K Harding
- College of Public Health and Human Sciences, Oregon State University, Milam Hall, Corvallis, OR, 97331, USA.
| | - John Molitor
- College of Public Health and Human Sciences, Oregon State University, Milam Hall, Corvallis, OR, 97331, USA.
| | - Molly L Kile
- College of Public Health and Human Sciences, Oregon State University, Milam Hall, Corvallis, OR, 97331, USA.
| |
Collapse
|
16
|
Cheng KC, Acevedo-Bolton V, Jiang RT, Klepeis NE, Ott WR, Kitanidis PK, Hildemann LM. Stochastic modeling of short-term exposure close to an air pollution source in a naturally ventilated room: an autocorrelated random walk method. JOURNAL OF EXPOSURE SCIENCE & ENVIRONMENTAL EPIDEMIOLOGY 2014; 24:311-318. [PMID: 24064529 DOI: 10.1038/jes.2013.63] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/04/2013] [Revised: 06/23/2013] [Accepted: 08/09/2013] [Indexed: 06/02/2023]
Abstract
For an actively emitting source such as cooking or smoking, indoor measurements have shown a strong "proximity effect" within 1 m. The significant increase in both the magnitude and variation of concentration near a source is attributable to transient high peaks that occur sporadically-and these "microplumes" cause great uncertainty in estimating personal exposure. Recent field studies in naturally ventilated rooms show that close-proximity concentrations are approximately lognormally distributed. We use the autocorrelated random walk method to represent the time-varying directionality of indoor emissions, thereby predicting the time series and frequency distributions of concentrations close to an actively emitting point source. The predicted 5-min concentrations show good agreement with measurements from a point source of CO in a naturally ventilated house-the measured and predicted frequency distributions at 0.5- and 1-m distances are similar and approximately lognormal over a concentration range spanning three orders of magnitude. By including the transient peak concentrations, this random airflow modeling method offers a way to more accurately assess acute exposure levels for cases where well-defined airflow patterns in an indoor space are not available.
Collapse
Affiliation(s)
- Kai-Chung Cheng
- 1] Civil and Environmental Engineering Department, Stanford University, Stanford, California, USA [2] Indoor Air Quality Section, Environmental Health Laboratory, California Department of Public Health, Richmond, California, USA
| | - Viviana Acevedo-Bolton
- Civil and Environmental Engineering Department, Stanford University, Stanford, California, USA
| | - Ruo-Ting Jiang
- Civil and Environmental Engineering Department, Stanford University, Stanford, California, USA
| | - Neil E Klepeis
- Civil and Environmental Engineering Department, Stanford University, Stanford, California, USA
| | - Wayne R Ott
- Civil and Environmental Engineering Department, Stanford University, Stanford, California, USA
| | - Peter K Kitanidis
- Civil and Environmental Engineering Department, Stanford University, Stanford, California, USA
| | - Lynn M Hildemann
- Civil and Environmental Engineering Department, Stanford University, Stanford, California, USA
| |
Collapse
|
17
|
Acevedo-Bolton V, Ott WR, Cheng KC, Jiang RT, Klepeis NE, Hildemann LM. Controlled experiments measuring personal exposure to PM2.5 in close proximity to cigarette smoking. INDOOR AIR 2014; 24:199-212. [PMID: 23808850 DOI: 10.1111/ina.12057] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/29/2012] [Accepted: 06/20/2013] [Indexed: 06/02/2023]
Abstract
Few measurements of exposure to secondhand smoke (SHS) in close proximity to a smoker are available. Recent health studies have demonstrated an association between acute (<2 h) exposures to high concentrations of SHS and increased risk of cardiovascular and respiratory disease. We performed 15 experiments inside naturally ventilated homes and 16 in outdoor locations, each with 2-4 non-smokers sitting near a cigarette smoker. The smoker's and non-smokers' real-time exposures to PM2.5 from SHS were measured by using TSI SidePak monitors to sample their breathing zones. In 87% of the residential indoor experiments, the smoker received the highest average exposure to SHS, with PM2.5 concentrations ranging from 50-630 μg/m(3) . During the active smoking period, individual non-smokers sitting within approximately 1 m of a smoker had average SHS exposures ranging from negligible up to >160 μg/m(3) of PM2.5 . The average incremental exposure of the non-smokers was higher indoors (42 μg/m(3) , n = 35) than outdoors (29 μg/m(3) , n = 47), but the overall indoor and outdoor frequency distributions were similar. The 10-s PM2.5 averages during the smoking periods showed great variability, with multiple high concentrations of short duration (microplumes) both indoors and outdoors.
Collapse
Affiliation(s)
- V Acevedo-Bolton
- Civil and Environmental Engineering Department, Stanford University, Stanford, CA, USA
| | | | | | | | | | | |
Collapse
|
18
|
Boor BE, Järnström H, Novoselac A, Xu Y. Infant exposure to emissions of volatile organic compounds from crib mattresses. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2014; 48:3541-3549. [PMID: 24548111 DOI: 10.1021/es405625q] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
Infants spend most of their time sleeping and are likely to be exposed to elevated concentrations of chemicals released from their crib mattresses. Small-scale chamber experiments were conducted to determine the area-specific emission rates (SERs) of volatile organic compounds (VOCs) in a collection of twenty new and used crib mattresses. All mattress samples were found to emit VOCs and the mean values of total VOC (TVOC) SERs were 56 μg/m(2)h at 23 °C and 139 μg/m(2)h at 36 °C. TVOC SERs were greater for new mattresses compared to used ones and were influenced by the type of foam material and the presence of mattress cover layer. A variety of VOCs were identified, with polyurethane foam releasing a greater diversity of VOCs compared to polyester foam. Large-scale chamber experiments were conducted with an infant thermal manikin. TVOC concentrations sampled in the breathing zone and interior pore air of the crib mattress foam were found to be greater than the bulk room air by factors in the range of 1.8 to 2.4 and 7.5 to 21, respectively. The results suggest that crib mattresses are an important source of VOCs and infant exposure to VOCs are possibly elevated in their sleep microenvironments.
Collapse
Affiliation(s)
- Brandon E Boor
- Department of Civil, Architectural, and Environmental Engineering, The University of Texas at Austin , Austin 78712, Texas, United States
| | | | | | | |
Collapse
|
19
|
Ott WR, Acevedo-Bolton V, Cheng KC, Jiang RT, Klepeis NE, Hildemann LM. Outdoor fine and ultrafine particle measurements at six bus stops with smoking on two California arterial highways--results of a pilot study. JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION (1995) 2014; 64:47-60. [PMID: 24620402 DOI: 10.1080/10962247.2013.832712] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
UNLABELLED As indoor smoking bans have become widely adopted, some U.S. communities are considering restricting smoking outdoors, creating a need for measurements of air pollution near smokers outdoors. Personal exposure experiments were conducted with four to five participants at six sidewalk bus stops located 1.5-3.3 m from the curb of two heavily traveled California arterial highways with 3300-5100 vehicles per hour. At each bus stop, a smoker in the group smoked a cigarette. Gravimetrically calibrated continuous monitors were used to measure fine particle concentrations (aerodynamic diameter < or = 2.5 microm; PM2.5) in the breathing zones (within 0.2 m from the nose and mouth) of each participant. At each bus stop, ultrafine particles (UFP), wind speed, temperature, relative humidity, and traffic counts were also measured. For 13 cigarette experiments, the mean PM2.5 personal exposure of the nonsmoker seated 0.5 m from the smoker during a 5-min cigarette ranged from 15 to 153 microg/m3. Of four persons seated on the bench, the smoker received the highest PM2.5 breathing-zone exposure of 192 microg/m3. There was a strong proximity effect: nonsmokers at distances 0.5, 1.0, and 1.5 m from the smoker received mean PM2.5 personal exposures of 59, 40, and 28 microg/m3, respectively, compared with a background level of 1.7 microg/m3. Like the PM2.5 concentrations, UFP concentrations measured 0.5 m from the smoker increased abruptly when a cigarette started and decreased when the cigarette ended, averaging 44,500 particles/cm3 compared with the background level of 7200 particles/cm3. During nonsmoking periods, the UFP background concentrations showed occasional peaks due to traffic, whereas PM2.5 background concentrations were extremely low. The results indicate that a single cigarette smoked outdoors at a bus stop can cause PM2.5 and UFP concentrations near the smoker that are 16-35 and 6.2 times, respectively, higher than the background concentrations due to cars and trucks on an adjacent arterial highway. IMPLICATIONS Rules banning smoking indoors have been widely adopted in the United States and in many countries. Some communities are considering smoking bans that would apply to outdoor locations. Although many measurements are available of pollutant concentrations from secondhand smoke at indoor locations, few measurements are available of exposure to secondhand smoke outdoors. This study provides new data on exposure to fine and ultrafine particles from secondhand smoke near a smoker outdoors. The levels are compared with the exposure measured next to a highway. The findings are important for policies that might be developed for reducing exposure to secondhand smoke outdoors.
Collapse
|
20
|
Repace J, Zhang B, Bondy SJ, Benowitz N, Ferrence R. Air quality, mortality, and economic benefits of a smoke - free workplace law for non-smoking Ontario bar workers. INDOOR AIR 2013; 23:93-104. [PMID: 23006034 DOI: 10.1111/ina.12004] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/21/2012] [Accepted: 09/13/2012] [Indexed: 06/01/2023]
Abstract
We estimated the impact of a smoke-free workplace bylaw on non-smoking bar workers' health in Ontario, Canada. We measured bar workers' urine cotinine before (n = 99) and after (n = 91) a 2004 smoke-free workplace bylaw. Using pharmacokinetic and epidemiological models, we estimated workers' fine-particle (PM2.5 ) air pollution exposure and mortality risks from workplace secondhand smoke (SHS). workers' pre-law geometric mean cotinine was 10.3 ng/ml; post-law dose declined 70% to 3.10 ng/ml and reported work hours of exposure by 90%. Pre-law, 97% of workers' doses exceeded the 90th percentile for Canadians of working age. Pre-law-estimated 8-h average workplace PM2.5 exposure from SHS was 419 μg/m(3) or 'Very Poor' air quality, while outdoor PM2.5 levels averaged 7 μg/m(3) , 'Very Good' air quality by Canadian Air Quality Standards. We estimated that the bar workers' annual mortality rate from workplace SHS exposure was 102 deaths per 100000 persons. This was 2.4 times the occupational disease fatality rate for all Ontario workers. We estimated that half to two-thirds of the 10620 Ontario bar workers were non-smokers. Accordingly, Ontario's smoke-free law saved an estimated 5-7 non-smoking bar workers' lives annually, valued at CA $50 million to $68 million (US $49 million to $66 million).
Collapse
Affiliation(s)
- J Repace
- Repace Associates Inc., Bowie 20720, MD, USA.
| | | | | | | | | |
Collapse
|