1
|
Ghosh R, Joung HA, Goncharov A, Palanisamy B, Ngo K, Pejcinovic K, Krockenberger N, Horn EJ, Garner OB, Ghazal E, O'Kula A, Arnaboldi PM, Dattwyler RJ, Ozcan A, Di Carlo D. Rapid single-tier serodiagnosis of Lyme disease. Nat Commun 2024; 15:7124. [PMID: 39164226 PMCID: PMC11336255 DOI: 10.1038/s41467-024-51067-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2023] [Accepted: 07/29/2024] [Indexed: 08/22/2024] Open
Abstract
Point-of-care serological and direct antigen testing offers actionable insights for diagnosing challenging illnesses, empowering distributed health systems. Here, we report a POC-compatible serologic test for Lyme disease (LD), leveraging synthetic peptides specific to LD antibodies and a paper-based platform for rapid, and cost-effective diagnosis. Antigenic epitopes conserved across Borrelia burgdorferi genospecies, targeted by IgG and IgM antibodies, are selected to develop a multiplexed panel for detection of LD antibodies from patient sera. Multiple peptide epitopes, when combined synergistically with a machine learning-based diagnostic model achieve high sensitivity without sacrificing specificity. Blinded validation with 15 LD-positive and 15 negative samples shows 95.5% sensitivity and 100% specificity. Blind testing with the CDC's LD repository samples confirms the test accuracy, matching lab-based two-tier results, correctly differentiating between LD and look-alike diseases. This LD diagnostic test could potentially replace the cumbersome two-tier testing, improving diagnosis and enabling earlier treatment while facilitating immune monitoring and surveillance.
Collapse
Affiliation(s)
- Rajesh Ghosh
- Bioengineering Department, University of California, Los Angeles, CA, 90095, USA
| | - Hyou-Arm Joung
- Electrical & Computer Engineering Department, University of California, Los Angeles, CA, 90095, USA
- California NanoSystems Institute (CNSI), University of California, Los Angeles, CA, 90095, USA
| | - Artem Goncharov
- Electrical & Computer Engineering Department, University of California, Los Angeles, CA, 90095, USA
- California NanoSystems Institute (CNSI), University of California, Los Angeles, CA, 90095, USA
| | - Barath Palanisamy
- Bioengineering Department, University of California, Los Angeles, CA, 90095, USA
| | - Kevin Ngo
- Bioengineering Department, University of California, Los Angeles, CA, 90095, USA
| | - Katarina Pejcinovic
- Bioengineering Department, University of California, Los Angeles, CA, 90095, USA
| | - Nicole Krockenberger
- Bioengineering Department, University of California, Los Angeles, CA, 90095, USA
| | | | - Omai B Garner
- Department of Pathology and Laboratory Medicine, University of California, Los Angeles, CA, 90095, USA
| | - Ezdehar Ghazal
- Department of Pathology, Microbiology, and Immunology, New York Medical College, Valhalla, NY, 10595, USA
| | - Andrew O'Kula
- Department of Pathology, Microbiology, and Immunology, New York Medical College, Valhalla, NY, 10595, USA
| | - Paul M Arnaboldi
- Department of Pathology, Microbiology, and Immunology, New York Medical College, Valhalla, NY, 10595, USA
- Biopeptides, Corp, Ridgefield, CT, 06877, USA
| | - Raymond J Dattwyler
- Department of Pathology, Microbiology, and Immunology, New York Medical College, Valhalla, NY, 10595, USA
- Biopeptides, Corp, Ridgefield, CT, 06877, USA
| | - Aydogan Ozcan
- Bioengineering Department, University of California, Los Angeles, CA, 90095, USA.
- Electrical & Computer Engineering Department, University of California, Los Angeles, CA, 90095, USA.
- California NanoSystems Institute (CNSI), University of California, Los Angeles, CA, 90095, USA.
- Department of Surgery, University of California, Los Angeles, CA, 90095, USA.
| | - Dino Di Carlo
- Bioengineering Department, University of California, Los Angeles, CA, 90095, USA.
- California NanoSystems Institute (CNSI), University of California, Los Angeles, CA, 90095, USA.
- Department of Mechanical Engineering, University of California, Los Angeles, CA, 90095, USA.
| |
Collapse
|
2
|
Bezinge L, Shih CJ, Richards DA, deMello AJ. Electrochemical Paper-Based Microfluidics: Harnessing Capillary Flow for Advanced Diagnostics. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2024:e2401148. [PMID: 38801400 DOI: 10.1002/smll.202401148] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/13/2024] [Revised: 04/29/2024] [Indexed: 05/29/2024]
Abstract
Electrochemical paper-based microfluidics has attracted much attention due to the promise of transforming point-of-care diagnostics by facilitating quantitative analysis with low-cost and portable analyzers. Such devices harness capillary flow to transport samples and reagents, enabling bioassays to be executed passively. Despite exciting demonstrations of capillary-driven electrochemical tests, conventional methods for fabricating electrodes on paper impede capillary flow, limit fluidic pathways, and constrain accessible device architectures. This account reviews recent developments in paper-based electroanalytical devices and offers perspective by revisiting key milestones in lateral flow tests and paper-based microfluidics engineering. The study highlights the benefits associated with electrochemical sensing and discusses how the detection modality can be leveraged to unlock novel functionalities. Particular focus is given to electrofluidic platforms that embed electrodes into paper for enhanced biosensing applications. Together, these innovations pave the way for diagnostic technologies that offer portability, quantitative analysis, and seamless integration with digital healthcare, all without compromising the simplicity of commercially available rapid diagnostic tests.
Collapse
Affiliation(s)
- Léonard Bezinge
- Department of Chemistry and Applied Biosciences, Institute for Chemical and Bioengineering, ETH Zürich, Vladimir-Prelog-Weg 1, Zürich, 8093, Switzerland
| | - Chih-Jen Shih
- Department of Chemistry and Applied Biosciences, Institute for Chemical and Bioengineering, ETH Zürich, Vladimir-Prelog-Weg 1, Zürich, 8093, Switzerland
| | - Daniel A Richards
- Department of Chemistry and Applied Biosciences, Institute for Chemical and Bioengineering, ETH Zürich, Vladimir-Prelog-Weg 1, Zürich, 8093, Switzerland
| | - Andrew J deMello
- Department of Chemistry and Applied Biosciences, Institute for Chemical and Bioengineering, ETH Zürich, Vladimir-Prelog-Weg 1, Zürich, 8093, Switzerland
| |
Collapse
|
3
|
Lehnert T, Gijs MAM. Microfluidic systems for infectious disease diagnostics. LAB ON A CHIP 2024; 24:1441-1493. [PMID: 38372324 DOI: 10.1039/d4lc00117f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/20/2024]
Abstract
Microorganisms, encompassing both uni- and multicellular entities, exhibit remarkable diversity as omnipresent life forms in nature. They play a pivotal role by supplying essential components for sustaining biological processes across diverse ecosystems, including higher host organisms. The complex interactions within the human gut microbiota are crucial for metabolic functions, immune responses, and biochemical signalling, particularly through the gut-brain axis. Viruses also play important roles in biological processes, for example by increasing genetic diversity through horizontal gene transfer when replicating inside living cells. On the other hand, infection of the human body by microbiological agents may lead to severe physiological disorders and diseases. Infectious diseases pose a significant burden on global healthcare systems, characterized by substantial variations in the epidemiological landscape. Fast spreading antibiotic resistance or uncontrolled outbreaks of communicable diseases are major challenges at present. Furthermore, delivering field-proven point-of-care diagnostic tools to the most severely affected populations in low-resource settings is particularly important and challenging. New paradigms and technological approaches enabling rapid and informed disease management need to be implemented. In this respect, infectious disease diagnostics taking advantage of microfluidic systems combined with integrated biosensor-based pathogen detection offers a host of innovative and promising solutions. In this review, we aim to outline recent activities and progress in the development of microfluidic diagnostic tools. Our literature research mainly covers the last 5 years. We will follow a classification scheme based on the human body systems primarily involved at the clinical level or on specific pathogen transmission modes. Important diseases, such as tuberculosis and malaria, will be addressed more extensively.
Collapse
Affiliation(s)
- Thomas Lehnert
- Laboratory of Microsystems, École Polytechnique Fédérale de Lausanne, Lausanne, CH-1015, Switzerland.
| | - Martin A M Gijs
- Laboratory of Microsystems, École Polytechnique Fédérale de Lausanne, Lausanne, CH-1015, Switzerland.
| |
Collapse
|
4
|
Lee S, Bi L, Chen H, Lin D, Mei R, Wu Y, Chen L, Joo SW, Choo J. Recent advances in point-of-care testing of COVID-19. Chem Soc Rev 2023; 52:8500-8530. [PMID: 37999922 DOI: 10.1039/d3cs00709j] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2023]
Abstract
Advances in microfluidic device miniaturization and system integration contribute to the development of portable, handheld, and smartphone-compatible devices. These advancements in diagnostics have the potential to revolutionize the approach to detect and respond to future pandemics. Accordingly, herein, recent advances in point-of-care testing (POCT) of coronavirus disease 2019 (COVID-19) using various microdevices, including lateral flow assay strips, vertical flow assay strips, microfluidic channels, and paper-based microfluidic devices, are reviewed. However, visual determination of the diagnostic results using only microdevices leads to many false-negative results due to the limited detection sensitivities of these devices. Several POCT systems comprising microdevices integrated with portable optical readers have been developed to address this issue. Since the outbreak of COVID-19, effective POCT strategies for COVID-19 based on optical detection methods have been established. They can be categorized into fluorescence, surface-enhanced Raman scattering, surface plasmon resonance spectroscopy, and wearable sensing. We introduced next-generation pandemic sensing methods incorporating artificial intelligence that can be used to meet global health needs in the future. Additionally, we have discussed appropriate responses of various testing devices to emerging infectious diseases and prospective preventive measures for the post-pandemic era. We believe that this review will be helpful for preparing for future infectious disease outbreaks.
Collapse
Affiliation(s)
- Sungwoon Lee
- Department of Chemistry, Chung-Ang University, Seoul 06974, South Korea.
| | - Liyan Bi
- School of Special Education and Rehabilitation, Binzhou Medical University, Yantai, 264003, China
| | - Hao Chen
- School of Environmental and Material Engineering, Yantai University, Yantai 264005, China
| | - Dong Lin
- School of Pharmacy, Bianzhou Medical University, Yantai, 264003, China
| | - Rongchao Mei
- CAS Key Laboratory of Coastal Environmental Processes and Ecological Remediation, Yantai Institute of Coastal Zone Research, Yantai 264003, China
| | - Yixuan Wu
- CAS Key Laboratory of Coastal Environmental Processes and Ecological Remediation, Yantai Institute of Coastal Zone Research, Yantai 264003, China
| | - Lingxin Chen
- CAS Key Laboratory of Coastal Environmental Processes and Ecological Remediation, Yantai Institute of Coastal Zone Research, Yantai 264003, China
- School of Pharmacy, Bianzhou Medical University, Yantai, 264003, China
| | - Sang-Woo Joo
- Department of Information Communication, Materials, and Chemistry Convergence Technology, Soongsil University, Seoul 06978, South Korea
| | - Jaebum Choo
- Department of Chemistry, Chung-Ang University, Seoul 06974, South Korea.
| |
Collapse
|
5
|
Goncharov A, Joung HA, Ghosh R, Han GR, Ballard ZS, Maloney Q, Bell A, Aung CTZ, Garner OB, Carlo DD, Ozcan A. Deep Learning-Enabled Multiplexed Point-of-Care Sensor using a Paper-Based Fluorescence Vertical Flow Assay. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2023; 19:e2300617. [PMID: 37104829 DOI: 10.1002/smll.202300617] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/21/2023] [Revised: 03/25/2023] [Indexed: 06/19/2023]
Abstract
Multiplexed computational sensing with a point-of-care serodiagnosis assay to simultaneously quantify three biomarkers of acute cardiac injury is demonstrated. This point-of-care sensor includes a paper-based fluorescence vertical flow assay (fxVFA) processed by a low-cost mobile reader, which quantifies the target biomarkers through trained neural networks, all within <15 min of test time using 50 µL of serum sample per patient. This fxVFA platform is validated using human serum samples to quantify three cardiac biomarkers, i.e., myoglobin, creatine kinase-MB, and heart-type fatty acid binding protein, achieving less than 0.52 ng mL-1 limit-of-detection for all three biomarkers with minimal cross-reactivity. Biomarker concentration quantification using the fxVFA that is coupled to neural network-based inference is blindly tested using 46 individually activated cartridges, which shows a high correlation with the ground truth concentrations for all three biomarkers achieving >0.9 linearity and <15% coefficient of variation. The competitive performance of this multiplexed computational fxVFA along with its inexpensive paper-based design and handheld footprint makes it a promising point-of-care sensor platform that can expand access to diagnostics in resource-limited settings.
Collapse
Affiliation(s)
- Artem Goncharov
- Electrical & Computer Engineering Department, University of California, Los Angeles, CA, 90095, USA
| | - Hyou-Arm Joung
- Electrical & Computer Engineering Department, University of California, Los Angeles, CA, 90095, USA
| | - Rajesh Ghosh
- Bioengineering Department, University of California, Los Angeles, CA, 90095, USA
| | - Gyeo-Re Han
- Electrical & Computer Engineering Department, University of California, Los Angeles, CA, 90095, USA
| | - Zachary S Ballard
- Electrical & Computer Engineering Department, University of California, Los Angeles, CA, 90095, USA
| | - Quinn Maloney
- Electrical & Computer Engineering Department, University of California, Los Angeles, CA, 90095, USA
| | - Alexandra Bell
- Chemistry & Biochemistry Department, University of California, Los Angeles, CA, 90095, USA
| | - Chew Tin Zar Aung
- Microbiology, Immunology & Molecular Genetics, University of California, Los Angeles, CA, 90095, USA
| | - Omai B Garner
- Department of Pathology and Laboratory Medicine, University of California, Los Angeles, CA, 90095, USA
| | - Dino Di Carlo
- Bioengineering Department, University of California, Los Angeles, CA, 90095, USA
- California NanoSystems Institute (CNSI), University of California, Los Angeles, CA, 90095, USA
| | - Aydogan Ozcan
- Electrical & Computer Engineering Department, University of California, Los Angeles, CA, 90095, USA
- Bioengineering Department, University of California, Los Angeles, CA, 90095, USA
- California NanoSystems Institute (CNSI), University of California, Los Angeles, CA, 90095, USA
| |
Collapse
|
6
|
Yadav SK, Verma D, Yadav U, Kalkal A, Priyadarshini N, Kumar A, Mahato K. Point-of-Care Devices for Viral Detection: COVID-19 Pandemic and Beyond. MICROMACHINES 2023; 14:1744. [PMID: 37763907 PMCID: PMC10535693 DOI: 10.3390/mi14091744] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/17/2023] [Revised: 08/29/2023] [Accepted: 08/30/2023] [Indexed: 09/29/2023]
Abstract
The pandemic of COVID-19 and its widespread transmission have made us realize the importance of early, quick diagnostic tests for facilitating effective cure and management. The primary obstacles encountered were accurately distinguishing COVID-19 from other illnesses including the flu, common cold, etc. While the polymerase chain reaction technique is a robust technique for the determination of SARS-CoV-2 in patients of COVID-19, there arises a high demand for affordable, quick, user-friendly, and precise point-of-care (POC) diagnostic in therapeutic settings. The necessity for available tests with rapid outcomes spurred the advancement of POC tests that are characterized by speed, automation, and high precision and accuracy. Paper-based POC devices have gained increasing interest in recent years because of rapid, low-cost detection without requiring external instruments. At present, microfluidic paper-based analysis devices have garnered public attention and accelerated the development of such POCT for efficient multistep assays. In the current review, our focus will be on the fabrication of detection modules for SARS-CoV-2. Here, we have included a discussion on various strategies for the detection of viral moieties. The compilation of these strategies would offer comprehensive insight into the detection of the causative agent preparedness for future pandemics. We also provide a descriptive outline for paper-based diagnostic platforms, involving the determination mechanisms, as well as a commercial kit for COVID-19 as well as their outlook.
Collapse
Affiliation(s)
- Sumit K. Yadav
- Department of Biotechnology, Vinoba Bhave University, Hazaribagh 825301, Jharkhand, India
| | - Damini Verma
- Department of Biosciences and Bioengineering, Indian Institute of Technology Roorkee, Roorkee 247667, Uttarakhand, India
| | - Ujala Yadav
- Department of Life Sciences, Central University of Jharkhand, Ranchi 835205, Jharkhand, India
| | - Ashish Kalkal
- Department of Biosciences and Bioengineering, Indian Institute of Technology Roorkee, Roorkee 247667, Uttarakhand, India
| | - Nivedita Priyadarshini
- Department of Zoology, DAV PG College Siwan, Jai Prakash University, Chhapra 841226, Bihar, India
| | - Ashutosh Kumar
- Department of Electrical Engineering, University of Notre Dame, Notre Dame, IN 46637, USA
| | - Kuldeep Mahato
- Department of Nanoengineering, University of California San Diego, 9500 Gilman Dr, La Jolla, San Diego, CA 92093, USA
| |
Collapse
|
7
|
Lacombe J, Summers AJ, Khanishayan A, Khorsandian Y, Hacey I, Blackson W, Zenhausern F. Paper-Based Vertical Flow Immunoassay for the Point-of-Care Multiplex Detection of Radiation Dosimetry Genes. Cytogenet Genome Res 2023; 163:178-186. [PMID: 37369178 PMCID: PMC10751381 DOI: 10.1159/000531702] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/24/2022] [Accepted: 06/18/2023] [Indexed: 06/29/2023] Open
Abstract
In a nuclear or radiological incident, first responders must quickly and accurately measure radiation exposure among civilians as medical countermeasures are radiation dose-dependent and time-sensitive. Although several approaches have been explored to measure absorbed radiation dose, there is an important need to develop point-of-care (POC) bioassay devices that can be used immediately to triage thousands of individuals potentially exposed to radiation. Here we present a proof-of-concept study showing the use of a paper-based vertical flow immunoassay (VFI) to detect radiation dosimetry genes. Using labeled primers during amplification and a multiplex membrane, our results showed that the nucleic acid VFI can simultaneously detect two biodosimetry genes, CDKN1A and DDB2, as well as one housekeeping gene MRPS5. The assay demonstrated good linearity and precision with an inter- and intra-assay coefficient of variance <20% and <10%, respectively. Moreover, the assay showed its ability to discriminate non-irradiated controls (0 Gy) from irradiated samples (1 + 2 Gy) with an overall sensitivity of 62.5% and specificity of 100% (AUC = 0.8672, 95% CI: 0.723-1.000; p = 0.004). Interestingly, the gene combination also showed a dose-dependent response for 0, 1, and 2 Gy, similar to data obtained by real-time PCR benchmark. These preliminary results suggest that a VFI platform can be used to detect simultaneously multiple genes that can be then quantified, thus offering a new approach for a POC biodosimetry assay that could be rapidly deployed on-site to test a large population and help triage and medical management after radiological event.
Collapse
Affiliation(s)
- Jerome Lacombe
- Center for Applied NanoBioscience and Medicine, College of Medicine Phoenix, University of Arizona, Phoenix, AZ, USA
- Department of Basic Medical Sciences, College of Medicine Phoenix, University of Arizona, Phoenix, AZ, USA
| | - Alexander J. Summers
- Center for Applied NanoBioscience and Medicine, College of Medicine Phoenix, University of Arizona, Phoenix, AZ, USA
| | - Ashkan Khanishayan
- Center for Applied NanoBioscience and Medicine, College of Medicine Phoenix, University of Arizona, Phoenix, AZ, USA
| | - Yasaman Khorsandian
- Center for Applied NanoBioscience and Medicine, College of Medicine Phoenix, University of Arizona, Phoenix, AZ, USA
| | - Isabella Hacey
- Center for Applied NanoBioscience and Medicine, College of Medicine Phoenix, University of Arizona, Phoenix, AZ, USA
| | - Wyatt Blackson
- Center for Applied NanoBioscience and Medicine, College of Medicine Phoenix, University of Arizona, Phoenix, AZ, USA
| | - Frederic Zenhausern
- Center for Applied NanoBioscience and Medicine, College of Medicine Phoenix, University of Arizona, Phoenix, AZ, USA
- Department of Basic Medical Sciences, College of Medicine Phoenix, University of Arizona, Phoenix, AZ, USA
- Department of Biomedical Engineering, College of Engineering, University of Arizona, Tucson, AZ, USA
| |
Collapse
|
8
|
Ghosh R, Joung HA, Goncharov A, Palanisamy B, Ngo K, Pejcinovic K, Krockenberger N, Horn EJ, Garner OB, Ghazal E, O’Kula A, Arnaboldi PM, Dattwyler RJ, Ozcan A, Di Carlo D. Single-tier point-of-care serodiagnosis of Lyme disease. BIORXIV : THE PREPRINT SERVER FOR BIOLOGY 2023:2023.06.14.544508. [PMID: 37398357 PMCID: PMC10312703 DOI: 10.1101/2023.06.14.544508] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 07/04/2023]
Abstract
Point-of-care (POC) serological testing provides actionable information for several difficult to diagnose illnesses, empowering distributed health systems. Accessible and adaptable diagnostic platforms that can assay the repertoire of antibodies formed against pathogens are essential to drive early detection and improve patient outcomes. Here, we report a POC serologic test for Lyme disease (LD), leveraging synthetic peptides tuned to be highly specific to the LD antibody repertoire across patients and compatible with a paper-based platform for rapid, reliable, and cost-effective diagnosis. A subset of antigenic epitopes conserved across Borrelia burgdorferi genospecies and targeted by IgG and IgM antibodies, were selected based on their seroreactivity to develop a multiplexed panel for a single-step measurement of combined IgM and IgG antibodies from LD patient sera. Multiple peptide epitopes, when combined synergistically using a machine learning-based diagnostic model, yielded a high sensitivity without any loss in specificity. We blindly tested the platform with samples from the U.S. Centers for Disease Control & Prevention (CDC) LD repository and achieved a sensitivity and specificity matching the lab-based two-tier results with a single POC test, correctly discriminating cross-reactive look-alike diseases. This computational LD diagnostic test can potentially replace the cumbersome two-tier testing paradigm, improving diagnosis and enabling earlier effective treatment of LD patients while also facilitating immune monitoring and surveillance of the disease in the community.
Collapse
Affiliation(s)
- Rajesh Ghosh
- Bioengineering Department, University of California, Los Angeles, CA 90095 USA
| | - Hyou-Arm Joung
- Electrical & Computer Engineering Department, University of California, Los Angeles, CA 90095 USA
- California NanoSystems Institute (CNSI), University of California, Los Angeles, CA 90095 USA
| | - Artem Goncharov
- Electrical & Computer Engineering Department, University of California, Los Angeles, CA 90095 USA
- California NanoSystems Institute (CNSI), University of California, Los Angeles, CA 90095 USA
| | - Barath Palanisamy
- Bioengineering Department, University of California, Los Angeles, CA 90095 USA
| | - Kevin Ngo
- Bioengineering Department, University of California, Los Angeles, CA 90095 USA
| | - Katarina Pejcinovic
- Bioengineering Department, University of California, Los Angeles, CA 90095 USA
| | | | | | - Omai B. Garner
- Department of Pathology and Laboratory Medicine, University of California, Los Angeles, CA 90095 USA
| | - Ezdehar Ghazal
- Department of Pathology, Microbiology, and Immunology, New York Medical College, Valhalla, New York 10595, United States
| | - Andrew O’Kula
- Department of Pathology, Microbiology, and Immunology, New York Medical College, Valhalla, New York 10595, United States
| | - Paul M. Arnaboldi
- Department of Pathology, Microbiology, and Immunology, New York Medical College, Valhalla, New York 10595, United States
- Biopeptides, Corp. East Setauket, NY 11733
| | - Raymond J. Dattwyler
- Department of Pathology, Microbiology, and Immunology, New York Medical College, Valhalla, New York 10595, United States
- Biopeptides, Corp. East Setauket, NY 11733
| | - Aydogan Ozcan
- Bioengineering Department, University of California, Los Angeles, CA 90095 USA
- Electrical & Computer Engineering Department, University of California, Los Angeles, CA 90095 USA
- California NanoSystems Institute (CNSI), University of California, Los Angeles, CA 90095 USA
- Department of Surgery, University of California, Los Angeles, CA 90095 USA
| | - Dino Di Carlo
- Bioengineering Department, University of California, Los Angeles, CA 90095 USA
- California NanoSystems Institute (CNSI), University of California, Los Angeles, CA 90095 USA
- Department of Mechanical Engineering, University of California, Los Angeles, CA 90095 USA
| |
Collapse
|
9
|
Woolf MS, Dignan LM, Karas SM, Lewis HM, Kim SN, Geise GM, DeMers HL, Hau D, Gates-Hollingsworth MA, AuCoin DP, Landers JP. Digital image analysis for biothreat detection via rapid centrifugal microfluidic orthogonal flow immunocapture. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2023; 15:1870-1880. [PMID: 36975002 DOI: 10.1039/d3ay00073g] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/18/2023]
Abstract
We report clear proof-of-principle for centrifugally-driven, multiplexed, paper-based orthogonal flow sandwich-style immunocapture (cOFI) and colorimetric detection of Zaire Ebola virus-like particles. Capture antibodies are immobilized onto nanoporous nitrocellulose membranes that are then laminated into polymeric microfluidic discs to yield ready-to-use analytical devices. Fluid flow is controlled solely by rotational speed, obviating the need for complex pneumatic pumping systems, and providing more precise flow control than with the capillary-driven flow used in traditional lateral flow immunoassays (LFIs). Samples containing the antigen of interest and gold nanoparticle-labeled detection antibodies are pumped centrifugally through the embedded, prefunctionalized membrane where they are subsequently captured to generate a positive, colorimetric signal. When compared to the equivalent LFI counterparts, this cOFI approach generated immunochromatographic colorimetric responses that are objectively darker (saturation), more intense (grayscale), and less variable regarding total area of the color response. We also describe an image analysis approach that enables access to rich color data and area statistics without the need for a commercial 'strip reader' or custom-written image analysis algorithms. Instead, our analytical method exploits inexpensive equipment (e.g., smart phone, flatbed scanner, etc.) and freely available software (Fiji distribution of ImageJ) to permit characterization of immunochromatographic responses that includes multiple color metrics, offering insights beyond typical grayscale analysis. The findings reported here stand as clear proof-of-principle for the feasibility of disc-based, centrifugally driven orthogonal flow through a membrane with immunocapture (cOFI) and colorimetric readout of a sandwich-type immunoassay in less than 15 minutes. Once fully developed, this cOFI platform could render a faster, more accurate diagnosis, while processing multiple samples simul-taneously.
Collapse
Affiliation(s)
- M Shane Woolf
- Department of Chemistry, University of Virginia, USA
| | - Leah M Dignan
- Department of Chemistry, University of Virginia, USA
| | - Scott M Karas
- Department of Chemistry, University of Virginia, USA
| | | | - Sabrina N Kim
- Department of Chemistry, University of Virginia, USA
| | | | - Haley L DeMers
- Department of Microbiology and Immunology, University of Nevada, Reno, USA
| | - Derrick Hau
- Department of Microbiology and Immunology, University of Nevada, Reno, USA
| | | | - David P AuCoin
- Department of Microbiology and Immunology, University of Nevada, Reno, USA
| | - James P Landers
- Department of Chemistry, University of Virginia, USA
- Department of Mechanical Engineering, University of Virginia, USA
- Department of Pathology, University of Virginia, USA
| |
Collapse
|
10
|
Surti PV, Kim MW, Phan LMT, Kailasa SK, Mungray AK, Park JP, Park TJ. Progress on dot-blot assay as a promising analytical tool: Detection from molecules to cells. Trends Analyt Chem 2022. [DOI: 10.1016/j.trac.2022.116736] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
|
11
|
Seok Y, Yin Q, Li R, Mauk MG, Bai H, Bau HH. Manually-Operated, Slider Cassette for Multiplexed Molecular Detection at the Point of Care. SENSORS AND ACTUATORS. B, CHEMICAL 2022; 369:132353. [PMID: 38756788 PMCID: PMC11097106 DOI: 10.1016/j.snb.2022.132353] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/18/2024]
Abstract
Effective control of epidemics, individualized medicine, and new drugs with virologic response-dependent dose and timing require, among other things, simple, inexpensive, multiplexed molecular detection platforms suitable for point of care and home use. Herein, we describe our progress towards developing such a platform that includes sample lysis, nucleic acid isolation, concentration, purification, and amplification. Our diagnostic device comprises a sliding component that houses the nucleic acid isolation membrane and a housing containing three amplification reaction chambers with dry stored reagents, blisters with buffers and wash solutions, and absorption pads to facilitate capillarity pull and waste storage. After sample introduction, the user slides the slider within the housing from one station to another to carry out various unit operations. The slider motion induces blisters to discharge their contents, effectuating washes, and eventual elution of captured nucleic acids into reaction chambers. The slider cassette mates with a processor that incubates isothermal amplification but can also be made to operate instrumentation-free. We demonstrate our cassette's utility for the co-detection of the human immunodeficiency virus (HIV), hepatitis B virus (HBV), and hepatitis C virus (HCV). These three blood-borne pathogens co-infect many people worldwide with severe personal and public health consequences.
Collapse
Affiliation(s)
- Youngung Seok
- Department of Mechanical Engineering and Applied Mechanics, School of Engineering and Applied Science, University of Pennsylvania, 216 Towne Building, 220 S. 33 Street, Philadelphia, PA 19104, USA
| | - Qingtian Yin
- Department of Mechanical Engineering and Applied Mechanics, School of Engineering and Applied Science, University of Pennsylvania, 216 Towne Building, 220 S. 33 Street, Philadelphia, PA 19104, USA
| | - Ruijie Li
- Department of Mechanical Engineering and Applied Mechanics, School of Engineering and Applied Science, University of Pennsylvania, 216 Towne Building, 220 S. 33 Street, Philadelphia, PA 19104, USA
- Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, 29 Zhongguancun East Road, Haidian District, Beijing, 100190, China
| | - Michael G. Mauk
- Department of Mechanical Engineering and Applied Mechanics, School of Engineering and Applied Science, University of Pennsylvania, 216 Towne Building, 220 S. 33 Street, Philadelphia, PA 19104, USA
| | - Huiwen Bai
- Department of Mechanical Engineering and Applied Mechanics, School of Engineering and Applied Science, University of Pennsylvania, 216 Towne Building, 220 S. 33 Street, Philadelphia, PA 19104, USA
| | - Haim H. Bau
- Department of Mechanical Engineering and Applied Mechanics, School of Engineering and Applied Science, University of Pennsylvania, 216 Towne Building, 220 S. 33 Street, Philadelphia, PA 19104, USA
| |
Collapse
|
12
|
Summers AJ, Devadhasan JP, Gu J, Montgomery DC, Fischer B, Gates-Hollingsworth MA, Pflughoeft KJ, Vo-Dinh T, AuCoin DP, Zenhausern F. Optimization of an Antibody Microarray Printing Process Using a Designed Experiment. ACS OMEGA 2022; 7:32262-32271. [PMID: 36120062 PMCID: PMC9476517 DOI: 10.1021/acsomega.2c03595] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/08/2022] [Accepted: 08/15/2022] [Indexed: 06/15/2023]
Abstract
Antibody microarrays have proven useful in immunoassay-based point-of-care diagnostics for infectious diseases. Noncontact piezoelectric inkjet printing has advantages to print antibody microarrays on nitrocellulose substrates for this application due to its compatibility with sensitive solutions and substrates, simple droplet control, and potential for high-capacity printing. However, there remain real-world challenges in printing such microarrays, which motivated this study. The effects of three concentrations of capture antibody (cAb) reagents and nozzle hydrostatic pressures were chosen to investigate three responses: the number of printed membrane disks, dispensing performance, and microarray quality. Printing conditions were found to be most ideal with 5 mg/mL cAb and a nozzle hydrostatic pressure near zero, which produced 130 membrane disks in a single print versus the 10 membrane disks per print before optimization. These results serve to inform efficient printing of antibody microarrays on nitrocellulose membranes for rapid immunoassay-based detection of infectious diseases and beyond.
Collapse
Affiliation(s)
- Alexander J. Summers
- Center
for Applied NanoBioscience and Medicine, College of Medicine, University of Arizona, Phoenix, Arizona 85004, United States
| | - Jasmine P. Devadhasan
- Center
for Applied NanoBioscience and Medicine, College of Medicine, University of Arizona, Phoenix, Arizona 85004, United States
| | - Jian Gu
- Center
for Applied NanoBioscience and Medicine, College of Medicine, University of Arizona, Phoenix, Arizona 85004, United States
- Department
of Basic Medical Sciences, The University
of Arizona, College of Medicine, 475 N 5th Street, Phoenix, Arizona 85004, United
States
| | - Douglas C. Montgomery
- School
of Computing and Augmented Intelligence, Arizona State University, Tempe, Arizona 85287-1004, United States
| | - Brittany Fischer
- School
of Computing and Augmented Intelligence, Arizona State University, Tempe, Arizona 85287-1004, United States
| | | | - Kathryn J. Pflughoeft
- Department
of Microbiology and Immunology, University
of Nevada School of Medicine, Reno, Nevada 89557-0705, United States
| | - Tuan Vo-Dinh
- Fitzpatrick
Institute for Photonics, Departments of Biomedical Engineering and
Chemistry, Duke University, Durham, North Carolina 27708-0281, United States
| | - David P. AuCoin
- Department
of Microbiology and Immunology, University
of Nevada School of Medicine, Reno, Nevada 89557-0705, United States
| | - Frederic Zenhausern
- Center
for Applied NanoBioscience and Medicine, College of Medicine, University of Arizona, Phoenix, Arizona 85004, United States
- Department
of Basic Medical Sciences, The University
of Arizona, College of Medicine, 475 N 5th Street, Phoenix, Arizona 85004, United
States
- Department
of Biomedical Engineering, The University
of Arizona, College of Engineering, 1127 E James E. Rogers Way, Tucson, Arizona 85721, United
States
| |
Collapse
|
13
|
Design of Gold Nanoparticle Vertical Flow Assays for Point-of-Care Testing. Diagnostics (Basel) 2022; 12:diagnostics12051107. [PMID: 35626263 PMCID: PMC9140445 DOI: 10.3390/diagnostics12051107] [Citation(s) in RCA: 17] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2022] [Revised: 04/24/2022] [Accepted: 04/25/2022] [Indexed: 01/18/2023] Open
Abstract
Vertical flow assays (VFAs) or flow-through assays have emerged as an alternate type of paper-based assay due to their faster detection time, larger sample volume capacity, and significantly higher multiplexing capabilities. They have been successfully employed to detect several different targets (polysaccharides, protein, and nucleic acids), although in a limited number of samples (serum, whole blood, plasma) compared to the more commonly known lateral flow assays (LFAs). The operation of a VFA relies mainly on gravity, coupled with capillary action or external force to help the sample flow through layers of stacked pads. With recent developments in this field, multiple layers of pads and signal readers have been optimized for more user-friendly operation, and VFAs have achieved a lower limit of detection for various analytes than the gold-standard methods. Thus, compared to the more widely used LFA, the VFA demonstrates certain advantages and is becoming an increasingly popular platform for obtaining qualitative and quantitative results in low-resource settings. Considering the wide application of gold nanoparticles (GNPs) in VFAs, we will mostly discuss (1) the design of GNP-based VFA along with its associated advantages/disadvantages, (2) fabrication and optimization of GNP-based VFAs for applications, and (3) the future outlook of flow-based assays for point-of-care testing (POCT) diagnostics.
Collapse
|
14
|
Pereira C, Parolo C, Idili A, Gomis RR, Rodrigues L, Sales G, Merkoçi A. Paper-based biosensors for cancer diagnostics. TRENDS IN CHEMISTRY 2022. [DOI: 10.1016/j.trechm.2022.03.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
|
15
|
Tahmasebi M, Bamdad T, Svendsen WE, Forouzandeh-Moghadam M. An enzymatic nucleic acid vertical flow assay. Anal Bioanal Chem 2022; 414:3605-3615. [PMID: 35352165 DOI: 10.1007/s00216-022-03988-7] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2021] [Revised: 02/16/2022] [Accepted: 02/22/2022] [Indexed: 11/28/2022]
Abstract
Vertical flow assays have been developed in recent years addressing limitations of the lateral flow assays, including limited multiplexing capability, quantitation, and hook effect. In the present study, the first passive paper-based vertical flow assay is developed for the detection of the nucleic acid target. Horseradish peroxidase was used as an enzymatic tracer with a high potential for signal amplification. In order to achieve the best signal-to-noise ratio, different parameters of paper-based assays were optimized. The sample is heat denatured and hybridized with a specific probe to form a dual-labeled hybridization complex. A small volume of diluted sample, 12 µl, can be analyzed within 6 min on the assay in a sandwich format. Assay specificity was evaluated by testing different unrelated samples, and also, 1.7 nM was obtained as the limit of detection (LOD) using the 0 + 3SD method, which is equivalent to 8.5 fmol of double-stranded DNA in the 12 µl sample volume. The linear range of 3-194 nM with a 0.978 correlation coefficient was obtained according to the calibration curve. The developed assay was evaluated with 45 hepatitis B virus clinical plasma samples, and the result showed 100% consistency of the assay with the real-time PCR benchmark. In the present study, we sought to develop a mere detection system for nucleic acid targets, and to investigate the possibility of using enzyme reporter in a passive vertical flow assay.
Collapse
Affiliation(s)
- Mehdi Tahmasebi
- Department of Medical Biotechnology, Faculty of Medical Sciences, Tarbiat Modares University, P.O. Box 14115-111, Tehran, Iran
| | - Taravat Bamdad
- Department of Medical Virology, Faculty of Medical Sciences, Tarbiat Modares University, P.O. Box 14115-111, Tehran, Iran
| | - Winnie Edith Svendsen
- Department of Micro and Nanotechnology, Technical University of Denmark, Ørsteds Plads, 2800 Kgs, Lyngby, Denmark
| | - Mehdi Forouzandeh-Moghadam
- Department of Medical Biotechnology, Faculty of Medical Sciences, Tarbiat Modares University, P.O. Box 14115-111, Tehran, Iran.
| |
Collapse
|
16
|
Woolf MS, Dignan LM, Karas SM, Lewis HM, Hadley KC, Nauman AQ, Gates-Hollingsworth MA, AuCoin DP, Green HR, Geise GM, Landers JP. Characterization of a Centrifugal Microfluidic Orthogonal Flow Platform. MICROMACHINES 2022; 13:487. [PMID: 35334778 PMCID: PMC8950265 DOI: 10.3390/mi13030487] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/02/2022] [Revised: 03/01/2022] [Accepted: 03/09/2022] [Indexed: 11/16/2022]
Abstract
To bring to bear the power of centrifugal microfluidics on vertical flow immunoassays, control of flow orthogonally through nanoporous membranes is essential. The on-disc approach described here leverages the rapid print-cut-laminate (PCL) disc fabrication and prototyping method to create a permanent seal between disc materials and embedded nanoporous membranes. Rotational forces drive fluid flow, replacing capillary action, and complex pneumatic pumping systems. Adjacent microfluidic features form a flow path that directs fluid orthogonally (vertically) through these embedded membranes during assay execution. This method for membrane incorporation circumvents the need for solvents (e.g., acetone) to create the membrane-disc bond and sidesteps issues related to undesirable bypass flow. In other recently published work, we described an orthogonal flow (OF) platform that exploited embedded membranes for automation of enzyme-linked immunosorbent assays (ELISAs). Here, we more fully characterize flow patterns and cellulosic membrane behavior within the centrifugal orthogonal flow (cOF) format. Specifically, high-speed videography studies demonstrate that sample volume, membrane pore size, and ionic composition of the sample matrix significantly impact membrane behavior, and consequently fluid drainage profiles, especially when cellulosic membranes are used. Finally, prototype discs are used to demonstrate proof-of-principle for sandwich-type antigen capture and immunodetection within the cOF system.
Collapse
Affiliation(s)
- Michael Shane Woolf
- Department of Chemistry, University of Virginia, Charlottesville, VA 22904, USA; (L.M.D.); (S.M.K.); (H.M.L.); (K.C.H.); (A.Q.N.); (J.P.L.)
| | - Leah M. Dignan
- Department of Chemistry, University of Virginia, Charlottesville, VA 22904, USA; (L.M.D.); (S.M.K.); (H.M.L.); (K.C.H.); (A.Q.N.); (J.P.L.)
| | - Scott M. Karas
- Department of Chemistry, University of Virginia, Charlottesville, VA 22904, USA; (L.M.D.); (S.M.K.); (H.M.L.); (K.C.H.); (A.Q.N.); (J.P.L.)
| | - Hannah M. Lewis
- Department of Chemistry, University of Virginia, Charlottesville, VA 22904, USA; (L.M.D.); (S.M.K.); (H.M.L.); (K.C.H.); (A.Q.N.); (J.P.L.)
| | - Kevyn C. Hadley
- Department of Chemistry, University of Virginia, Charlottesville, VA 22904, USA; (L.M.D.); (S.M.K.); (H.M.L.); (K.C.H.); (A.Q.N.); (J.P.L.)
| | - Aeren Q. Nauman
- Department of Chemistry, University of Virginia, Charlottesville, VA 22904, USA; (L.M.D.); (S.M.K.); (H.M.L.); (K.C.H.); (A.Q.N.); (J.P.L.)
- TeGrex Technologies, Charlottesville, VA 22903, USA
| | | | - David P. AuCoin
- Department of Chemical Engineering, University of Virginia, Charlottesville, VA 22904, USA; (M.A.G.-H.); (D.P.A.); (H.R.G.)
| | - Heather R. Green
- Department of Chemical Engineering, University of Virginia, Charlottesville, VA 22904, USA; (M.A.G.-H.); (D.P.A.); (H.R.G.)
| | - Geoffrey M. Geise
- Department of Chemical Engineering, University of Virginia, Charlottesville, VA 22904, USA;
| | - James P. Landers
- Department of Chemistry, University of Virginia, Charlottesville, VA 22904, USA; (L.M.D.); (S.M.K.); (H.M.L.); (K.C.H.); (A.Q.N.); (J.P.L.)
- Department of Mechanical Engineering, University of Virginia, Charlottesville, VA 22904, USA
- Department of Pathology, University of Virginia, Charlottesville, VA 22904, USA
| |
Collapse
|
17
|
Guo H, Yin Z, Namkoong M, Li Y, Nguyen T, Salcedo E, Arizpe I, Tian L. Printed Ultrastable Bioplasmonic Microarrays for Point-of-Need Biosensing. ACS APPLIED MATERIALS & INTERFACES 2022; 14:10729-10737. [PMID: 35171552 PMCID: PMC9359782 DOI: 10.1021/acsami.1c24458] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/14/2023]
Abstract
Paper-based point-of-need (PON) biosensors are attractive for various applications, including food safety, agriculture, disease diagnosis, and drug screening, owing to their low cost and ease of use. However, existing paper-based biosensors mainly rely on biolabels, colorimetric reagents, and biorecognition elements and exhibit limited stability under harsh environments. Here, we report a label-free paper-based biosensor composed of bioplasmonic microarrays for sensitive detection and quantification of protein targets in small volumes of biofluids. Bioplasmonic microarrays were printed using an ultrastable bioplasmonic ink, rendering the PON sensors excellent thermal, chemical, and biological stability for their reliable performance in resource-limited settings. We fabricated silicone hydrophobic barriers and bioplasmonic microarrays with direct writing and droplet jetting approaches on a three-dimensional (3D) nanoporous paper. Direct writing hydrophobic barriers can define hydrophilic channels less than 100 μm wide. High-resolution patterning of hydrophilic test domains enables the handling and analysis of small fluid volumes. We show that the plasmonic sensors based on a vertical flow assay provide similar sensitivity and low limit of detection with a 60 μL sample volume compared to those with 500 μL samples based on an immersion approach and can shorten assay time from 90 to 20 min.
Collapse
Affiliation(s)
- Heng Guo
- Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843, USA
| | - Ze Yin
- Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843, USA
| | - Myeong Namkoong
- Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843, USA
| | - Yixuan Li
- Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843, USA
| | - Tan Nguyen
- Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843, USA
| | - Elizabeth Salcedo
- Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843, USA
| | - Ivanna Arizpe
- Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843, USA
| | | |
Collapse
|
18
|
Tan HY, Yang J, Linnes JC, Welch CJ, Bruening ML. Quantitation of Trastuzumab and an Antibody to SARS-CoV-2 in Minutes Using Affinity Membranes in 96-Well Plates. Anal Chem 2022; 94:884-891. [PMID: 34982935 PMCID: PMC8751022 DOI: 10.1021/acs.analchem.1c03654] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2021] [Accepted: 12/20/2021] [Indexed: 11/28/2022]
Abstract
Quantitation of therapeutic monoclonal antibodies (mAbs) in human serum could ensure that patients have adequate levels of mAbs for effective treatment. This research describes the use of affinity, glass-fiber membranes in a 96-well-plate format for rapid (<5 min) quantitation of the therapeutic mAb trastuzumab and a mAb against the SARS-CoV-2 spike protein. Adsorption of a poly(acrylic acid)-containing film in membrane pores and activation of the -COOH groups in the film enable covalent-linking of affinity peptides or proteins to the membrane. Passage of mAb-containing serum through the affinity membrane results in mAb capture within 1 min. Subsequent rinsing, binding of a secondary antibody conjugated to a fluorophore, and a second rinse yield mAb-concentration-dependent fluorescence intensities in the wells. Calibration curves established from analyses on different days have low variability and allow determination of mAb levels in separately prepared samples with an average error <10%, although errors in single-replicate measurements may reach 40%. The assays can occur in diluted serum with physiologically relevant mAb concentrations, as well as in undiluted serum. Thus, the combination of 96-well plates containing affinity membranes, a microplate reader, and a simple vacuum manifold affords convenient mAb quantitation in <5 min.
Collapse
Affiliation(s)
- Hui Yin Tan
- Department
of Chemistry and Biochemistry, University
of Notre Dame, Notre
Dame, Indiana 46556, United States
| | - Junyan Yang
- Department
of Chemical and Biomolecular Engineering, University of Notre Dame, Notre
Dame, Indiana 46556, United States
| | - Jacqueline C. Linnes
- Weldon
School of Bioengineering, Purdue University, West Lafayette, Indiana 47907, United States
| | - Christopher J. Welch
- Indiana
Consortium for Analytical Science & Engineering (ICASE), 410 W. 10th Street, # 1020H, Indianapolis, Indiana 46202, United States
| | - Merlin L. Bruening
- Department
of Chemistry and Biochemistry, University
of Notre Dame, Notre
Dame, Indiana 46556, United States
- Department
of Chemical and Biomolecular Engineering, University of Notre Dame, Notre
Dame, Indiana 46556, United States
| |
Collapse
|
19
|
Kim KR, Lee KW, Chun HJ, Lee D, Kim JH, Yoon HC. Wash-free operation of smartphone-integrated optical immunosensor using retroreflective microparticles. Biosens Bioelectron 2022; 196:113722. [PMID: 34700265 DOI: 10.1016/j.bios.2021.113722] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2021] [Revised: 09/09/2021] [Accepted: 10/16/2021] [Indexed: 12/28/2022]
Abstract
Herein, we introduce a smartphone-integrated immunosensor based on non-spectroscopic optical detection. Sedimentation of the retroreflector and gentle inversion of the microfluidic chip was chosen as biosensing principles to ensure minimal human involvement. To realize this, wash-free immunosensing was implemented on a polymeric microfluidic chip device fabricated for light signal penetration in retroreflection signal acquisition. Applying a transparent chip and passive modulation of retroreflectors enabled the minimization of human error during sensing. In addition, a retroreflection-detectable optical gadget was constructed for integration with the commercial smartphone. The gadget had an optical chamber that induced retroreflection by integration with a smartphone. When the micro-sized reflector, named the retroreflective Janus microparticle, reacted on the sensing surface, the incident light was retroreflected towards the image sensor and quantified by a smartphone-installed Android application package. The developed application package features include time-lapse image capture performed by manipulating LED flash and camera modules, and quantification of retroreflected signal counts by image processing of time-lapse images. With this platform, the user could independently commence optical signal processing without a complicated optical setup and running software on a PC, and sensitive and reproducible immunosensing results could be obtained. The applicability test for creatine kinase-myocardial band detection from the buffer to serum was conducted and presented a calibration curve of 0-1000 ng/mL within 1 h. With the developed system, we believe that the applicability of the platform in bioanalytical detection can be expanded.
Collapse
Affiliation(s)
- Ka Ram Kim
- Department of Molecular Science & Technology, Ajou University, Suwon, 16499, Republic of Korea
| | - Kyung Won Lee
- Department of Molecular Science & Technology, Ajou University, Suwon, 16499, Republic of Korea
| | - Hyeong Jin Chun
- Department of Molecular Science & Technology, Ajou University, Suwon, 16499, Republic of Korea
| | - Danbi Lee
- Department of Molecular Science & Technology, Ajou University, Suwon, 16499, Republic of Korea
| | - Jae-Ho Kim
- Department of Molecular Science & Technology, Ajou University, Suwon, 16499, Republic of Korea
| | - Hyun C Yoon
- Department of Molecular Science & Technology, Ajou University, Suwon, 16499, Republic of Korea.
| |
Collapse
|
20
|
Hou Y, Lv CC, Guo YL, Ma XH, Liu W, Jin Y, Li BX, Yang M, Yao SY. Recent Advances and Applications in Paper-Based Devices for Point-of-Care Testing. JOURNAL OF ANALYSIS AND TESTING 2022; 6:247-273. [PMID: 35039787 PMCID: PMC8755517 DOI: 10.1007/s41664-021-00204-w] [Citation(s) in RCA: 39] [Impact Index Per Article: 19.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2021] [Accepted: 11/16/2021] [Indexed: 12/11/2022]
Abstract
Point-of-care testing (POCT), as a portable and user-friendly technology, can obtain accurate test results immediately at the sampling point. Nowadays, microfluidic paper-based analysis devices (μPads) have attracted the eye of the public and accelerated the development of POCT. A variety of detection methods are combined with μPads to realize precise, rapid and sensitive POCT. This article mainly introduced the development of electrochemistry and optical detection methods on μPads for POCT and their applications on disease analysis, environmental monitoring and food control in the past 5 years. Finally, the challenges and future development prospects of μPads for POCT were discussed.
Collapse
Affiliation(s)
- Yue Hou
- Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi'an, 710062 China
| | - Cong-Cong Lv
- Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi'an, 710062 China
| | - Yan-Li Guo
- Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi'an, 710062 China
| | - Xiao-Hu Ma
- Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi'an, 710062 China
| | - Wei Liu
- Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi'an, 710062 China
| | - Yan Jin
- Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi'an, 710062 China
| | - Bao-Xin Li
- Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi'an, 710062 China
| | - Min Yang
- Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi'an, 710062 China
| | - Shi-Yin Yao
- Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi'an, 710062 China
| |
Collapse
|
21
|
Raza T, Qu L, Khokhar WA, Andrews B, Ali A, Tian M. Progress of Wearable and Flexible Electrochemical Biosensors With the Aid of Conductive Nanomaterials. Front Bioeng Biotechnol 2021; 9:761020. [PMID: 34881233 PMCID: PMC8645837 DOI: 10.3389/fbioe.2021.761020] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2021] [Accepted: 10/11/2021] [Indexed: 11/17/2022] Open
Abstract
Conductive nanomaterials have recently gained a lot of interest due to their excellent physical, chemical, and electrical properties, as well as their numerous nanoscale morphologies, which enable them to be fabricated into a wide range of modern chemical and biological sensors. This study focuses mainly on current applications based on conductive nanostructured materials. They are the key elements in preparing wearable electrochemical Biosensors, including electrochemical immunosensors and DNA biosensors. Conductive nanomaterials such as carbon (Carbon Nanotubes, Graphene), metals and conductive polymers, which provide a large effective surface area, fast electron transfer rate and high electrical conductivity, are summarized in detail. Conductive polymer nanocomposites in combination with carbon and metal nanoparticles have also been addressed to increase sensor performance. In conclusion, a section on current challenges and opportunities in this growing field is forecasted at the end.
Collapse
Affiliation(s)
- Tahir Raza
- Research Center for Intelligent and Wearable Technology, College of Textiles and Clothing, State Key Laboratory of Bio-Fibers and Eco-Textiles, Intelligent Wearable Engineering Research Center of Qingdao, Qingdao University, Qingdao, China
| | - Lijun Qu
- Research Center for Intelligent and Wearable Technology, College of Textiles and Clothing, State Key Laboratory of Bio-Fibers and Eco-Textiles, Intelligent Wearable Engineering Research Center of Qingdao, Qingdao University, Qingdao, China
| | | | - Boakye Andrews
- Research Center for Intelligent and Wearable Technology, College of Textiles and Clothing, State Key Laboratory of Bio-Fibers and Eco-Textiles, Intelligent Wearable Engineering Research Center of Qingdao, Qingdao University, Qingdao, China
| | | | - Mingwei Tian
- Research Center for Intelligent and Wearable Technology, College of Textiles and Clothing, State Key Laboratory of Bio-Fibers and Eco-Textiles, Intelligent Wearable Engineering Research Center of Qingdao, Qingdao University, Qingdao, China
| |
Collapse
|
22
|
Wang L, Wang X, Cheng L, Ding S, Wang G, Choo J, Chen L. SERS-based test strips: Principles, designs and applications. Biosens Bioelectron 2021; 189:113360. [PMID: 34051383 DOI: 10.1016/j.bios.2021.113360] [Citation(s) in RCA: 82] [Impact Index Per Article: 27.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2020] [Revised: 05/10/2021] [Accepted: 05/16/2021] [Indexed: 10/21/2022]
Abstract
Test strips represent a class of point-of-care testing (POCT) tools for analysis of a variety of biomarkers towards diagnostics. Conventional test strips offer benefits of simple operation, visualization, and short detection time, along with the drawbacks of relatively low sensitivity and unavailability of quantitative analysis. Recently, the combination of surface-enhanced Raman scattering (SERS) and test strips have evolved to provide a powerful platform capable of ultrasensitive and multiplex detection of extensive analytes of interest. In this review, we focus on the working principles, design strategies and POCT applications of SERS-based test strips. Initially, both lateral and vertical flow test strips are briefly introduced, followed by presentation of various strategies for reforming SERS-based test strips with better detection performance. Applications of SERS-based test strips in diagnosis of disease biomarkers, nucleic acids and toxins are reviewed, with an emphasis on SERS tag design, sensitivity and analytical applicability. Finally, conclusions are made and perspectives on futuristic research directions are given.
Collapse
Affiliation(s)
- Luyang Wang
- College of Food Science and Engineering, Ocean University of China, 5 Yushan Road, Qingdao, 266003, China
| | - Xiaokun Wang
- Shandong Provincial Key Laboratory of Biochemical Engineering, College of Marine Science and Biological Engineering, Qingdao University of Science and Technology, Qingdao, 266042, China
| | - Lu Cheng
- College of Food Science and Engineering, Ocean University of China, 5 Yushan Road, Qingdao, 266003, China
| | - Shansen Ding
- College of Food Science and Engineering, Ocean University of China, 5 Yushan Road, Qingdao, 266003, China
| | - Guoqing Wang
- College of Food Science and Engineering, Ocean University of China, 5 Yushan Road, Qingdao, 266003, China; Laboratory for Marine Drugs and Bioproducts of Qingdao National Laboratory for Marine Science and Technology, Qingdao, 266237, China.
| | - Jaebum Choo
- Department of Chemistry, Chung-Ang University, Seoul, 06974, South Korea.
| | - Lingxin Chen
- CAS Key Laboratory of Coastal Environmental Processes and Ecological Remediation, Shandong Key Laboratory of Coastal Environmental Processes, Yantai Institute of Coastal Zone Research, Chinese Academy of Sciences, Yantai, 264003, China; College of Chemistry and Chemical Engineering, Qufu Normal University, Qufu, 273165, China.
| |
Collapse
|
23
|
Devadhasan JP, Gu J, Chen P, Smith S, Thomas B, Gates-Hollingsworth M, Hau D, Pandit S, AuCoin D, Zenhausern F. Critical Comparison between Large and Mini Vertical Flow Immunoassay Platforms for Yersinia Pestis Detection. Anal Chem 2021; 93:9337-9344. [PMID: 33989499 DOI: 10.1021/acs.analchem.0c05278] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Yersinia pestis is a Gram-negative bacterium that is the causative agent of plague and is widely recognized as a potential biological weapon. Due to the high fatality rate of plague when diagnosis is delayed, the development of rapid, sensitive, specific, and cost-effective methods is needed for its diagnosis. The Y. pestis low calcium response V (LcrV) protein has been identified as a potential microbial biomarker for the diagnosis of plague. In this paper, we present a highly sensitive, paper-based, vertical flow immunoassay (VFI) prototype for the detection of LcrV and the diagnosis of plague. An antigen-capture assay using monoclonal antibodies is employed to capture and detect the LcrV protein, using a colorimetric approach. In addition, the effect of miniaturizing the VFI device is explored based on two different sizes of VFI platforms, denoted as "large VFI" and "mini VFI." Also, a comparative analysis is performed between the VFI platform and a lateral flow immunoassay (LFI) platform to exhibit the improved assay sensitivity suitable for point-of-care (POC) diagnostics. The analytical sensitivity or limit of detection (LOD) in the mini VFI is approximately 0.025 ng/mL, that is, 10 times better than that of the large VFI platform or 80 times over a standard lateral flow configuration. The low LOD of the LcrV VFI appears to be highly suitable for testing clinical samples and potentially diagnosing plague at earlier time points. In addition, optimization of the gold nanoparticle (AuNP) concentration, nanomaterial plasmonic properties, and flow velocity analysis could improve the performance of the VFI. Furthermore, we developed automated image analysis software that shows potential for integrating the diagnostic system into a smartphone. These methods and findings demonstrate that the VFI platform is a highly sensitive device for detecting the LcrV and potentially many other biomarkers.
Collapse
Affiliation(s)
- Jasmine Pramila Devadhasan
- Center for Applied NanoBioscience and Medicine, College of Medicine, University of Arizona, Phoenix, Arizona 85004, United States
| | - Jian Gu
- Center for Applied NanoBioscience and Medicine, College of Medicine, University of Arizona, Phoenix, Arizona 85004, United States.,Department of Basic Medical Sciences, College of Medicine, The University of Arizona, 475 N 5th Street, Phoenix, Arizona 85004, United States
| | - Peng Chen
- Center for Applied NanoBioscience and Medicine, College of Medicine, University of Arizona, Phoenix, Arizona 85004, United States
| | - Stanley Smith
- Center for Applied NanoBioscience and Medicine, College of Medicine, University of Arizona, Phoenix, Arizona 85004, United States
| | - Baiju Thomas
- Center for Applied NanoBioscience and Medicine, College of Medicine, University of Arizona, Phoenix, Arizona 85004, United States
| | | | - Derrick Hau
- Department of Microbiology and Immunology, University of Nevada School of Medicine, Reno, Nevada 89557, United States
| | - Sujata Pandit
- Department of Microbiology and Immunology, University of Nevada School of Medicine, Reno, Nevada 89557, United States
| | - David AuCoin
- Department of Microbiology and Immunology, University of Nevada School of Medicine, Reno, Nevada 89557, United States
| | - Frederic Zenhausern
- Center for Applied NanoBioscience and Medicine, College of Medicine, University of Arizona, Phoenix, Arizona 85004, United States.,Department of Basic Medical Sciences, College of Medicine, The University of Arizona, 475 N 5th Street, Phoenix, Arizona 85004, United States
| |
Collapse
|
24
|
Ouyang M, Tu D, Tong L, Sarwar M, Bhimaraj A, Li C, Coté GL, Di Carlo D. A review of biosensor technologies for blood biomarkers toward monitoring cardiovascular diseases at the point-of-care. Biosens Bioelectron 2021; 171:112621. [PMID: 33120234 DOI: 10.1016/j.bios.2020.112621] [Citation(s) in RCA: 55] [Impact Index Per Article: 18.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2019] [Revised: 09/06/2020] [Accepted: 09/14/2020] [Indexed: 01/03/2023]
Abstract
Cardiovascular diseases (CVDs) cause significant mortality globally. Notably, CVDs disproportionately negatively impact underserved populations, such as those that are economically disadvantaged and often located in remote regions. Devices to measure cardiac biomarkers have traditionally been focused on large instruments in a central laboratory but the development of affordable, portable devices that measure multiple cardiac biomarkers at the point-of-care (POC) are needed to improve clinical outcomes for patients, especially in underserved populations. Considering the enormity of the global CVD problem, complexity of CVDs, and the large candidate pool of biomarkers, it is of great interest to evaluate and compare biomarker performance and identify potential multiplexed panels that can be used in combination with affordable and robust biosensors at the POC toward improved patient care. This review focuses on describing the known and emerging CVD biosensing technologies for analysis of cardiac biomarkers from blood. Initially, the global burden of CVDs and the standard of care for the primary CVD categories, namely heart failure (HF) and acute coronary syndrome (ACS) including myocardial infarction (MI) are discussed. The latest United States, Canadian and European society guidelines recommended standalone, emerging, and add-on cardiac biomarkers, as well as their combinations are then described for the prognosis, diagnosis, and risk stratification of CVDs. Finally, both commercial in vitro biosensing devices and recent state-of-art techniques for detection of cardiac biomarkers are reviewed that leverage single and multiplexed panels of cardiac biomarkers with a view toward affordable, compact devices with excellent performance for POC diagnosis and monitoring.
Collapse
Affiliation(s)
- Mengxing Ouyang
- Department of Bioengineering, University of California, Los Angeles, 420 Westwood Plaza, Los Angeles, CA, 90095, USA
| | - Dandan Tu
- Department of Biomedical Engineering, Texas A&M University, 400 Bizzell St, College Station, TX, 77843, USA
| | - Lin Tong
- Nanobioengineering/Bioelectronics Lab, Department of Biomedical Engineering, Florida International University, 10555 West Flagler Street, Miami, FL, 33174, USA
| | - Mehenur Sarwar
- Nanobioengineering/Bioelectronics Lab, Department of Biomedical Engineering, Florida International University, 10555 West Flagler Street, Miami, FL, 33174, USA
| | - Arvind Bhimaraj
- Department of Cardiology, Houston Methodist J.C. Walter Transplant Center, Houston Methodist Hospital, 6550 Fannin St., Houston, TX, 77030, USA
| | - Chenzhong Li
- Nanobioengineering/Bioelectronics Lab, Department of Biomedical Engineering, Florida International University, 10555 West Flagler Street, Miami, FL, 33174, USA.
| | - Gerard L Coté
- Department of Biomedical Engineering, Texas A&M University, 400 Bizzell St, College Station, TX, 77843, USA; Center for Remote Health Technologies & Systems, Texas A&M Engineering Experiment Station, 101 Bizzell St, College Station, TX, 77840, USA.
| | - Dino Di Carlo
- Department of Bioengineering, University of California, Los Angeles, 420 Westwood Plaza, Los Angeles, CA, 90095, USA.
| |
Collapse
|
25
|
Khamcharoen W, Siangproh W. A multilayer microfluidic paper coupled with an electrochemical platform developed for sample separation and detection of dopamine. NEW J CHEM 2021. [DOI: 10.1039/d1nj02271g] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
A new construction of a multilayer electrochemical microfluidic paper-based analytical device using a single drop of the sample solution was performed for highly selective detection of dopamine in the presence of ascorbic acid interference.
Collapse
Affiliation(s)
- Wisarut Khamcharoen
- Department of Chemistry
- Faculty of Science
- Srinakharinwirot University
- Bangkok 10110
- Thailand
| | - Weena Siangproh
- Department of Chemistry
- Faculty of Science
- Srinakharinwirot University
- Bangkok 10110
- Thailand
| |
Collapse
|
26
|
Dabbagh SR, Becher E, Ghaderinezhad F, Havlucu H, Ozcan O, Ozkan M, Yetisen AK, Tasoglu S. Increasing the packing density of assays in paper-based microfluidic devices. BIOMICROFLUIDICS 2021; 15:011502. [PMID: 33569089 PMCID: PMC7864678 DOI: 10.1063/5.0042816] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/05/2021] [Accepted: 01/07/2021] [Indexed: 05/04/2023]
Abstract
Paper-based devices have a wide range of applications in point-of-care diagnostics, environmental analysis, and food monitoring. Paper-based devices can be deployed to resource-limited countries and remote settings in developed countries. Paper-based point-of-care devices can provide access to diagnostic assays without significant user training to perform the tests accurately and timely. The market penetration of paper-based assays requires decreased device fabrication costs, including larger packing density of assays (i.e., closely packed features) and minimization of assay reagents. In this review, we discuss fabrication methods that allow for increasing packing density and generating closely packed features in paper-based devices. To ensure that the paper-based device is low-cost, advanced fabrication methods have been developed for the mass production of closely packed assays. These emerging methods will enable minimizing the volume of required samples (e.g., liquid biopsies) and reagents in paper-based microfluidic devices.
Collapse
Affiliation(s)
| | - Elaina Becher
- Department of Biomedical Engineering, University of Connecticut, Storrs, Connecticut 06269, USA
| | - Fariba Ghaderinezhad
- Department of Mechanical Engineering, University of Connecticut, Storrs, Connecticut 06269, USA
| | - Hayati Havlucu
- Koç University Arçelik Research Center for Creative Industries (KUAR), Koç University, Sariyer, Istanbul 34450, Turkey
| | - Oguzhan Ozcan
- Koç University Arçelik Research Center for Creative Industries (KUAR), Koç University, Sariyer, Istanbul 34450, Turkey
| | - Mehmed Ozkan
- Boğaziçi Institute of Biomedical Engineering, Boğaziçi University, Çengelköy, Istanbul 34684, Turkey
| | - Ali Kemal Yetisen
- Department of Chemical Engineering, Imperial College London, London SW7 2AZ, United Kingdom
| | | |
Collapse
|
27
|
Chen YT, Lee YC, Lai YH, Lim JC, Huang NT, Lin CT, Huang JJ. Review of Integrated Optical Biosensors for Point-Of-Care Applications. BIOSENSORS-BASEL 2020; 10:bios10120209. [PMID: 33353033 PMCID: PMC7766912 DOI: 10.3390/bios10120209] [Citation(s) in RCA: 67] [Impact Index Per Article: 16.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/23/2020] [Revised: 12/12/2020] [Accepted: 12/16/2020] [Indexed: 12/25/2022]
Abstract
This article reviews optical biosensors and their integration with microfluidic channels. The integrated biosensors have the advantages of higher accuracy and sensitivity because they can simultaneously monitor two or more parameters. They can further incorporate many functionalities such as electrical control and signal readout monolithically in a single semiconductor chip, making them ideal candidates for point-of-care testing. In this article, we discuss the applications by specifically looking into point-of-care testing (POCT) using integrated optical sensors. The requirement and future perspective of integrated optical biosensors for POC is addressed.
Collapse
Affiliation(s)
- Yung-Tsan Chen
- Graduate Institute of Photonics and Optoelectronics, National Taiwan University, No. 1, Sec. 4, Roosevelt Road, Taipei 106, Taiwan; (Y.-T.C.); (Y.-C.L.); (Y.-H.L.); (J.-C.L.)
| | - Ya-Chu Lee
- Graduate Institute of Photonics and Optoelectronics, National Taiwan University, No. 1, Sec. 4, Roosevelt Road, Taipei 106, Taiwan; (Y.-T.C.); (Y.-C.L.); (Y.-H.L.); (J.-C.L.)
| | - Yao-Hsuan Lai
- Graduate Institute of Photonics and Optoelectronics, National Taiwan University, No. 1, Sec. 4, Roosevelt Road, Taipei 106, Taiwan; (Y.-T.C.); (Y.-C.L.); (Y.-H.L.); (J.-C.L.)
| | - Jin-Chun Lim
- Graduate Institute of Photonics and Optoelectronics, National Taiwan University, No. 1, Sec. 4, Roosevelt Road, Taipei 106, Taiwan; (Y.-T.C.); (Y.-C.L.); (Y.-H.L.); (J.-C.L.)
| | - Nien-Tsu Huang
- Department of Electrical Engineering, National Taiwan University, No. 1, Sec. 4, Roosevelt Road, Taipei 106, Taiwan; (N.-T.H.); (C.-T.L.)
- Graduate Institute of Biomedical Electronics and Bioinformatics, National Taiwan University, No. 1, Sec. 4, Roosevelt Road, Taipei 106, Taiwan
| | - Chih-Ting Lin
- Department of Electrical Engineering, National Taiwan University, No. 1, Sec. 4, Roosevelt Road, Taipei 106, Taiwan; (N.-T.H.); (C.-T.L.)
- Graduate Institute of Biomedical Electronics and Bioinformatics, National Taiwan University, No. 1, Sec. 4, Roosevelt Road, Taipei 106, Taiwan
- Graduate Institute of Electronics Engineering, National Taiwan University, No. 1, Sec. 4, Roosevelt Road, Taipei 106, Taiwan
| | - Jian-Jang Huang
- Graduate Institute of Photonics and Optoelectronics, National Taiwan University, No. 1, Sec. 4, Roosevelt Road, Taipei 106, Taiwan; (Y.-T.C.); (Y.-C.L.); (Y.-H.L.); (J.-C.L.)
- Department of Electrical Engineering, National Taiwan University, No. 1, Sec. 4, Roosevelt Road, Taipei 106, Taiwan; (N.-T.H.); (C.-T.L.)
- Correspondence:
| |
Collapse
|
28
|
Ray A, Esparza S, Wu D, Hanudel MR, Joung HA, Gales B, Tseng D, Salusky IB, Ozcan A. Measurement of serum phosphate levels using a mobile sensor. Analyst 2020; 145:1841-1848. [PMID: 31960836 DOI: 10.1039/c9an02215e] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
The measurement of serum phosphate concentration is crucial for patients with advanced chronic kidney disease (CKD) and those on maintenance dialysis, as abnormal phosphate levels may be associated with severe health risks. It is important to monitor serum phosphate levels on a regular basis in these patients; however, such measurements are generally limited to every 0.5-3 months, depending on the severity of CKD. This is due to the fact that serum phosphate measurements can only be performed at regular clinic visits, in addition to cost considerations. Here we present a portable and cost-effective point-of-care device capable of measuring serum phosphate levels using a single drop of blood (<60 μl). This is achieved by integrating a paper-based microfluidic platform with a custom-designed smartphone reader. This mobile sensor was tested on patients undergoing dialysis, where whole blood samples were acquired before starting the hemodialysis and during the three-hour treatment. This sampling during the hemodialysis, under patient consent, allowed us to test blood samples with a wide range of phosphate concentrations, and our results showed a strong correlation with the ground truth laboratory tests performed on the same patient samples (Pearson coefficient r = 0.95 and p < 0.001). Our 3D-printed smartphone attachment weighs about 400 g and costs less than 80 USD, whereas the material cost for the disposable test is <3.5 USD (under low volume manufacturing). This low-cost and easy-to-operate system can be used to measure serum phosphate levels at the point-of-care in about 45 min and can potentially be used on a daily basis by patients at home.
Collapse
Affiliation(s)
- Aniruddha Ray
- Department of Electrical and Computer Engineering, University of California, Los Angeles, CA 90095, USA. and Department of Bioengineering, University of California, Los Angeles, CA 90095, USA and California NanoSystems Institute, University of California, Los Angeles, CA 90095, USA and Department of Pediatrics, David Geffen School of Medicine, University of California, Los Angeles, CA 90095, USA. and Department of Physics and Astronomy, University of Toledo, Toledo, OH 43606, USA
| | - Sarah Esparza
- Department of Bioengineering, University of California, Los Angeles, CA 90095, USA
| | - Dimei Wu
- Department of Bioengineering, University of California, Los Angeles, CA 90095, USA
| | - Mark R Hanudel
- Department of Pediatrics, David Geffen School of Medicine, University of California, Los Angeles, CA 90095, USA.
| | - Hyou-Arm Joung
- Department of Electrical and Computer Engineering, University of California, Los Angeles, CA 90095, USA. and Department of Bioengineering, University of California, Los Angeles, CA 90095, USA and California NanoSystems Institute, University of California, Los Angeles, CA 90095, USA
| | - Barbara Gales
- Department of Pediatrics, David Geffen School of Medicine, University of California, Los Angeles, CA 90095, USA.
| | - Derek Tseng
- Department of Electrical and Computer Engineering, University of California, Los Angeles, CA 90095, USA. and Department of Bioengineering, University of California, Los Angeles, CA 90095, USA and California NanoSystems Institute, University of California, Los Angeles, CA 90095, USA
| | - Isidro B Salusky
- Department of Pediatrics, David Geffen School of Medicine, University of California, Los Angeles, CA 90095, USA.
| | - Aydogan Ozcan
- Department of Electrical and Computer Engineering, University of California, Los Angeles, CA 90095, USA. and Department of Bioengineering, University of California, Los Angeles, CA 90095, USA and California NanoSystems Institute, University of California, Los Angeles, CA 90095, USA and Department of Surgery, David Geffen School of Medicine, University of California, Los Angeles, CA 90095, USA
| |
Collapse
|
29
|
Nath P, Kabir A, Khoubafarin Doust S, Kreais ZJ, Ray A. Detection of Bacterial and Viral Pathogens Using Photonic Point-of-Care Devices. Diagnostics (Basel) 2020; 10:diagnostics10100841. [PMID: 33086578 PMCID: PMC7603237 DOI: 10.3390/diagnostics10100841] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2020] [Revised: 10/05/2020] [Accepted: 10/15/2020] [Indexed: 12/15/2022] Open
Abstract
Infectious diseases caused by bacteria and viruses are highly contagious and can easily be transmitted via air, water, body fluids, etc. Throughout human civilization, there have been several pandemic outbreaks, such as the Plague, Spanish Flu, Swine-Flu, and, recently, COVID-19, amongst many others. Early diagnosis not only increases the chance of quick recovery but also helps prevent the spread of infections. Conventional diagnostic techniques can provide reliable results but have several drawbacks, including costly devices, lengthy wait time, and requirement of trained professionals to operate the devices, making them inaccessible in low-resource settings. Thus, a significant effort has been directed towards point-of-care (POC) devices that enable rapid diagnosis of bacterial and viral infections. A majority of the POC devices are based on plasmonics and/or microfluidics-based platforms integrated with mobile readers and imaging systems. These techniques have been shown to provide rapid, sensitive detection of pathogens. The advantages of POC devices include low-cost, rapid results, and portability, which enables on-site testing anywhere across the globe. Here we aim to review the recent advances in novel POC technologies in detecting bacteria and viruses that led to a breakthrough in the modern healthcare industry.
Collapse
|
30
|
Chen M, Li H, Shi Z, Peng W, Qin Y, Luo R, Zhou D, Gong X, Chang J. High fluorescence quenching probe-based reverse fluorescence enhancement LFTS coupling with IS-primer amplification reaction for the rapid and sensitive Parkinson Disease-associated MicroRNA detection. Biosens Bioelectron 2020; 165:112278. [DOI: 10.1016/j.bios.2020.112278] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2019] [Revised: 04/28/2020] [Accepted: 05/04/2020] [Indexed: 02/07/2023]
|
31
|
Flynn C, Ignaszak A. Lyme Disease Biosensors: A Potential Solution to a Diagnostic Dilemma. BIOSENSORS 2020; 10:E137. [PMID: 32998254 PMCID: PMC7601730 DOI: 10.3390/bios10100137] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/26/2020] [Revised: 09/24/2020] [Accepted: 09/27/2020] [Indexed: 02/06/2023]
Abstract
Over the past four decades, Lyme disease has remained a virulent and pervasive illness, persisting throughout North America and many other regions of the world. Recent increases in illness in many countries has sparked a renewed interest in improved Lyme diagnostics. While current standards of diagnosis are acceptable for the late stages of the disease, it remains difficult to accurately diagnose early forms of the illness. In addition, current diagnostic methods tend to be relatively expensive and require a large degree of laboratory-based analysis. Biosensors represent the fusion of biological materials with chemical techniques to provide simple, inexpensive alternatives to traditional diagnostic methods. Lyme disease biosensors have the potential to better diagnose early stages of the illness and provide possible patients with an inexpensive, commercially available test. This review examines the current state of Lyme disease biosensing, with a focus on previous biosensor development and essential future considerations.
Collapse
Affiliation(s)
- Connor Flynn
- Department of Chemistry, University of New Brunswick, Fredericton, NB E3B 5A3, Canada;
| | | |
Collapse
|
32
|
Parlak O, Richter-Dahlfors A. Bacterial Sensing and Biofilm Monitoring for Infection Diagnostics. Macromol Biosci 2020; 20:e2000129. [PMID: 32588553 DOI: 10.1002/mabi.202000129] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2020] [Revised: 06/01/2020] [Indexed: 12/21/2022]
Abstract
Recent insights into the rapidly emerging field of bacterial sensing and biofilm monitoring for infection diagnostics are discussed as well as recent key developments and emerging technologies in the field. Electrochemical sensing of bacteria and bacterial biofilm via synthetic, natural, and engineered recognition, as well as direct redox-sensing approaches via algorithm-based optical sensing, and tailor-made optotracing technology are discussed. These technologies are highlighted to answer the very critical question: "how can fast and accurate bacterial sensing and biofilm monitoring be achieved? Following on from that: "how can these different sensing concepts be translated for use in infection diagnostics? A central obstacle to this transformation is the absence of direct and fast analysis methods that provide high-throughput results and bio-interfaces that can control and regulate the means of communication between biological and electronic systems. Here, the overall progress made to date in building such translational efforts at the level of an individual bacterial cell to a bacterial community is discussed.
Collapse
Affiliation(s)
- Onur Parlak
- AIMES-Center for the Advancement of Integrated Medical and Engineering Science, Karolinska Institutet and KTH Royal Institute of Technology, Stockholm, SE-171 77, Sweden.,Department of Neuroscience, Karolinska Institutet, Stockholm, SE-171 77, Sweden
| | - Agneta Richter-Dahlfors
- AIMES-Center for the Advancement of Integrated Medical and Engineering Science, Karolinska Institutet and KTH Royal Institute of Technology, Stockholm, SE-171 77, Sweden.,Department of Neuroscience, Karolinska Institutet, Stockholm, SE-171 77, Sweden.,Fibre and Polymer Technology, KTH Royal Institute of Technology, Stockholm, SE-100 44, Sweden
| |
Collapse
|
33
|
Yang Y, Huang HY, Guo CS. Polarization holographic microscope slide for birefringence imaging of anisotropic samples in microfluidics. OPTICS EXPRESS 2020; 28:14762-14773. [PMID: 32403511 DOI: 10.1364/oe.389973] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/07/2020] [Accepted: 03/11/2020] [Indexed: 05/27/2023]
Abstract
Birefringence is an important optical property of anisotropic materials arising from anisotropies of tissue microstructures. Birefringence parameters have been found to be important to understand optical anisotropic architecture of many materials and polarization imaging has been applied in many researches in the field of biology and medicine. Here, we propose a scheme to miniaturize a double-channel polarization holographic interferometer optics to create a polarization holographic microscope slide (P-HMS) suitable for integrating with microfluidic lab-on-a-chip (LoC) systems. Based on the P-HMS combined with a simple reconstruction algorithm described in the paper, we can not only simultaneously realize holographic imaging of two orthogonal polarization components of dynamic samples in a microfluidic channel but also quantitative measurement of 2D birefringence information, both including the birefringence phase retardation and optic-axis orientation. This chip interferometer allows for off-axis double-channel polarization digital holographic recording using only a single illumination beam without need of any beam splitter or mirror. Its quasi-common path configuration and self-aligned design also make it tolerant to vibrations and misalignment. This work about the P-HMS could play a positive role in promoting the application of birefringence imaging in microfluidic LoC technology.
Collapse
|
34
|
Ballard ZS, Joung HA, Goncharov A, Liang J, Nugroho K, Di Carlo D, Garner OB, Ozcan A. Deep learning-enabled point-of-care sensing using multiplexed paper-based sensors. NPJ Digit Med 2020; 3:66. [PMID: 32411827 PMCID: PMC7206101 DOI: 10.1038/s41746-020-0274-y] [Citation(s) in RCA: 50] [Impact Index Per Article: 12.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2020] [Accepted: 04/09/2020] [Indexed: 12/16/2022] Open
Abstract
We present a deep learning-based framework to design and quantify point-of-care sensors. As a use-case, we demonstrated a low-cost and rapid paper-based vertical flow assay (VFA) for high sensitivity C-Reactive Protein (hsCRP) testing, commonly used for assessing risk of cardio-vascular disease (CVD). A machine learning-based framework was developed to (1) determine an optimal configuration of immunoreaction spots and conditions, spatially-multiplexed on a sensing membrane, and (2) to accurately infer target analyte concentration. Using a custom-designed handheld VFA reader, a clinical study with 85 human samples showed a competitive coefficient-of-variation of 11.2% and linearity of R 2 = 0.95 among blindly-tested VFAs in the hsCRP range (i.e., 0-10 mg/L). We also demonstrated a mitigation of the hook-effect due to the multiplexed immunoreactions on the sensing membrane. This paper-based computational VFA could expand access to CVD testing, and the presented framework can be broadly used to design cost-effective and mobile point-of-care sensors.
Collapse
Affiliation(s)
- Zachary S. Ballard
- Department of Electrical and Computer Engineering, University of California, Los Angeles, CA USA
- California NanoSystems Institute, University of California, Los Angeles, CA USA
| | - Hyou-Arm Joung
- Department of Electrical and Computer Engineering, University of California, Los Angeles, CA USA
- Department of Bioengineering, University of California, Los Angeles, CA USA
| | - Artem Goncharov
- Department of Electrical and Computer Engineering, University of California, Los Angeles, CA USA
| | - Jesse Liang
- California NanoSystems Institute, University of California, Los Angeles, CA USA
- Department of Bioengineering, University of California, Los Angeles, CA USA
| | - Karina Nugroho
- Department of Bioengineering, University of California, Los Angeles, CA USA
| | - Dino Di Carlo
- California NanoSystems Institute, University of California, Los Angeles, CA USA
- Department of Bioengineering, University of California, Los Angeles, CA USA
| | - Omai B. Garner
- Department of Pathology and Medicine, University of California, Los Angeles, CA USA
| | - Aydogan Ozcan
- Department of Electrical and Computer Engineering, University of California, Los Angeles, CA USA
- California NanoSystems Institute, University of California, Los Angeles, CA USA
- Department of Bioengineering, University of California, Los Angeles, CA USA
| |
Collapse
|
35
|
Lee HB, Meeseepong M, Trung TQ, Kim BY, Lee NE. A wearable lab-on-a-patch platform with stretchable nanostructured biosensor for non-invasive immunodetection of biomarker in sweat. Biosens Bioelectron 2020; 156:112133. [PMID: 32174559 DOI: 10.1016/j.bios.2020.112133] [Citation(s) in RCA: 60] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2019] [Revised: 02/18/2020] [Accepted: 03/02/2020] [Indexed: 12/20/2022]
Abstract
Conformable, wearable biosensor-integrated systems are a promising approach to non-invasive and quantitative on-body detection of biomarkers in body fluids. However, realizing such a system has been slowed by the difficulty of fabricating a soft affinity-based biosensor patch capable of precise on-body fluid handling with minimal wearer intervention and a simple measurement protocol. Herein, we demonstrate a conformable, wearable lab-on-a-patch (LOP) platform composed of a stretchable, label-free, impedimetric biosensor and a stretchable microfluidic device for on-body detection of the hormone biomarker, cortisol. The all-in-one, stretchable microfluidic device can precisely collect and deliver sweat for cortisol quantitation and offers one-touch operation of reagent delivery for simultaneous electrochemical signal generation and washing. Three-dimensional nanostructuring of the Au working electrode enables the high sensitivity required to detect the pM-levels of cortisol in sweat. Our integrated LOP detected sweat cortisol quantitatively and accurately during exercise. This LOP will open a new horizon for non-invasive, highly sensitive, and quantitative on-body immunodetection for wearable personal diagnostics.
Collapse
Affiliation(s)
- Han-Byeol Lee
- School of Advanced Materials Science & Engineering, Sungkyunkwan University, 2066 Seobu-ro, Jangan-gu, Suwon-si, Gyunggi-do, 16419, South Korea
| | - Montri Meeseepong
- SKKU Advanced Institute of Nano Technology (SAINT), Sungkyunkwan University, 2066 Seobu-ro, Jangan-gu, Suwon-si, Gyunggi-do, 16419, South Korea
| | - Tran Quang Trung
- School of Advanced Materials Science & Engineering, Sungkyunkwan University, 2066 Seobu-ro, Jangan-gu, Suwon-si, Gyunggi-do, 16419, South Korea
| | - Bo-Yeong Kim
- SKKU Advanced Institute of Nano Technology (SAINT), Sungkyunkwan University, 2066 Seobu-ro, Jangan-gu, Suwon-si, Gyunggi-do, 16419, South Korea
| | - Nae-Eung Lee
- School of Advanced Materials Science & Engineering, Sungkyunkwan University, 2066 Seobu-ro, Jangan-gu, Suwon-si, Gyunggi-do, 16419, South Korea; SKKU Advanced Institute of Nano Technology (SAINT), Sungkyunkwan University, 2066 Seobu-ro, Jangan-gu, Suwon-si, Gyunggi-do, 16419, South Korea; Samsung Advanced Institute for Health Sciences and Technology (SAIHST), Sungkyunkwan University, 2066 Seobu-ro, Jangan-gu, Suwon-si, Gyunggi-do, 16419, South Korea; Institute of Quantum Biophysics (IQB), Sungkyunkwan University, 2066 Seobu-ro, Jangan-gu, Suwon-si, Gyunggi-do, 16419, South Korea; Biomedical Institute for Convergence at SKKU (BICS) Sungkyunkwan University, 2066 Seobu-ro, Jangan-gu, Suwon-si, Gyunggi-do, 16419, South Korea.
| |
Collapse
|
36
|
Joung HA, Ballard ZS, Wu J, Tseng DK, Teshome H, Zhang L, Horn EJ, Arnaboldi PM, Dattwyler RJ, Garner OB, Di Carlo D, Ozcan A. Point-of-Care Serodiagnostic Test for Early-Stage Lyme Disease Using a Multiplexed Paper-Based Immunoassay and Machine Learning. ACS NANO 2020; 14:229-240. [PMID: 31849225 DOI: 10.1021/acsnano.9b08151] [Citation(s) in RCA: 45] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/16/2023]
Abstract
Caused by the tick-borne spirochete Borrelia burgdorferi, Lyme disease (LD) is the most common vector-borne infectious disease in North America and Europe. Though timely diagnosis and treatment are effective in preventing disease progression, current tests are insensitive in early stage LD, with a sensitivity of <50%. Additionally, the serological testing currently recommended by the U.S. Center for Disease Control has high costs (>$400/test) and extended sample-to-answer timelines (>24 h). To address these challenges, we created a cost-effective and rapid point-of-care (POC) test for early-stage LD that assays for antibodies specific to seven Borrelia antigens and a synthetic peptide in a paper-based multiplexed vertical flow assay (xVFA). We trained a deep-learning-based diagnostic algorithm to select an optimal subset of antigen/peptide targets and then blindly tested our xVFA using human samples (N(+) = 42, N(-) = 54), achieving an area-under-the-curve (AUC), sensitivity, and specificity of 0.950, 90.5%, and 87.0%, respectively, outperforming previous LD POC tests. With batch-specific standardization and threshold tuning, the specificity of our blind-testing performance improved to 96.3%, with an AUC and sensitivity of 0.963 and 85.7%, respectively.
Collapse
Affiliation(s)
- Hyou-Arm Joung
- Department of Electrical & Computer Engineering , University of California , Los Angeles , California 90025 , United States
- California NanoSystems Institute (CNSI) , University of California , Los Angeles , California 90025 , United States
- Department of Bioengineering , University of California , Los Angeles , California 90025 , United States
| | - Zachary S Ballard
- Department of Electrical & Computer Engineering , University of California , Los Angeles , California 90025 , United States
- California NanoSystems Institute (CNSI) , University of California , Los Angeles , California 90025 , United States
- Department of Bioengineering , University of California , Los Angeles , California 90025 , United States
| | - Jing Wu
- Department of Electrical & Computer Engineering , University of California , Los Angeles , California 90025 , United States
- Department of Chemistry , Lanzhou University , Lanzhou , Gansu 730000 , China
| | - Derek K Tseng
- Department of Electrical & Computer Engineering , University of California , Los Angeles , California 90025 , United States
| | - Hailemariam Teshome
- Department of Neuroscience , University of California , Los Angeles , California 90025 , United States
| | - Linghao Zhang
- Department of Mechanical Engineering , University of California , Los Angeles , California 90025 , United States
| | | | - Paul M Arnaboldi
- Department of Microbiology/Immunology , New York Medical College , Valhalla , New York 10595 , United States
| | - Raymond J Dattwyler
- Department of Microbiology/Immunology , New York Medical College , Valhalla , New York 10595 , United States
| | - Omai B Garner
- Department of Pathology and Laboratory Medicine , University of California , Los Angeles , California 90025 , United States
| | - Dino Di Carlo
- California NanoSystems Institute (CNSI) , University of California , Los Angeles , California 90025 , United States
- Department of Bioengineering , University of California , Los Angeles , California 90025 , United States
- Department of Mechanical Engineering , University of California , Los Angeles , California 90025 , United States
| | - Aydogan Ozcan
- Department of Electrical & Computer Engineering , University of California , Los Angeles , California 90025 , United States
- California NanoSystems Institute (CNSI) , University of California , Los Angeles , California 90025 , United States
- Department of Bioengineering , University of California , Los Angeles , California 90025 , United States
- Department of Surgery , University of California , Los Angeles , California 90025 , United States
| |
Collapse
|
37
|
Kim MW, Park HJ, Park CY, Kim JH, Cho CH, Phan LMT, Park JP, Kailasa SK, Lee CH, Park TJ. Fabrication of a paper strip for facile and rapid detection of bovine viral diarrhea virus via signal enhancement by copper polyhedral nanoshells. RSC Adv 2020; 10:29759-29764. [PMID: 35518256 PMCID: PMC9056175 DOI: 10.1039/d0ra03677c] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2020] [Accepted: 07/03/2020] [Indexed: 11/27/2022] Open
Abstract
The detection of bovine viral diarrhea virus (BVDV), which is a pathogen inducing fatal gastrointestinal disease in cattle, is becoming a momentous issue in the livestock farm. In that, BVDV is related to inapparent infection and various diseases with high transmissibility; it has also led to considerable economic losses. In this study, a simple dot-blotting method was devised to construct a rapid screening system for BVDV. Based on the BVDV-specific bioreceptors, it was anchored on the gold nanoparticles (AuNPs) to generate the seeding sites for signaling; then the signals were amplified by adopting the overgrowth of copper nano-polyhedral shells on AuNPs. The developed detection system shows a low detection limit of 4.4 copies per mL, and even this could be distinguished with naked eyes. These results indicate that the designed nanobiosensor possesses not only high sensitivity and selectivity but also potential usage on a point-of-care testing platform for BVDV. A rapid and simple affinity dot-blotting scheme via signal enhancement by copper nano-polyhedral shells on the surface of gold nanoparticles.![]()
Collapse
Affiliation(s)
- Min Woo Kim
- Department of Chemistry
- Research Institute of Chem-Bio Diagnostic Technology
- Chung-Ang University
- Seoul 06974
- Republic of Korea
| | - Hong-Je Park
- R&D Center
- Medexx Co., Ltd
- Seongnam-si
- Republic of Korea
- Department of Food Science and Biotechnology of Animal Resources
| | - Chan Yeong Park
- Department of Chemistry
- Research Institute of Chem-Bio Diagnostic Technology
- Chung-Ang University
- Seoul 06974
- Republic of Korea
| | - Ji Hong Kim
- Department of Food Science and Biotechnology
- Chung-Ang University
- Ansung 17546
- Republic of Korea
| | - Chae Hwan Cho
- Department of Food Science and Biotechnology
- Chung-Ang University
- Ansung 17546
- Republic of Korea
| | - Le Minh Tu Phan
- Department of Chemistry
- Research Institute of Chem-Bio Diagnostic Technology
- Chung-Ang University
- Seoul 06974
- Republic of Korea
| | - Jong Pil Park
- Department of Food Science and Biotechnology
- Chung-Ang University
- Ansung 17546
- Republic of Korea
| | - Suresh Kumar Kailasa
- Department of Applied Chemistry
- Sardar Vallabhbhai National Institute of Technology
- Surat-395007
- India
| | - Chi-Ho Lee
- Department of Food Science and Biotechnology of Animal Resources
- Konkuk University
- Seoul 05029
- Republic of Korea
| | - Tae Jung Park
- Department of Chemistry
- Research Institute of Chem-Bio Diagnostic Technology
- Chung-Ang University
- Seoul 06974
- Republic of Korea
| |
Collapse
|
38
|
Huang Y, Xu T, Wang W, Wen Y, Li K, Qian L, Zhang X, Liu G. Lateral flow biosensors based on the use of micro- and nanomaterials: a review on recent developments. Mikrochim Acta 2019; 187:70. [PMID: 31853644 DOI: 10.1007/s00604-019-3822-x] [Citation(s) in RCA: 64] [Impact Index Per Article: 12.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2019] [Accepted: 09/12/2019] [Indexed: 12/25/2022]
Abstract
This review (with 187 refs.) summarizes the progress that has been made in the design of lateral flow biosensors (LFBs) based on the use of micro- and nano-materials. Following a short introduction into the field, a first section covers features related to the design of LFBs, with subsections on strip-based, cotton thread-based and vertical flow- and syringe-based LFBs. The next chapter summarizes methods for sample pretreatment, from simple method to membrane-based methods, pretreatment by magnetic methods to device-integrated sample preparation. Advances in flow control are treated next, with subsections on cross-flow strategies, delayed and controlled release and various other strategies. Detection conditionst and mathematical modelling are briefly introduced in the following chapter. A further chapter covers methods for reliability improvement, for example by adding other validation lines or adopting different detection methods. Signal readouts are summarized next, with subsections on color-based, luminescent, smartphone-based and SERS-based methods. A concluding section summarizes the current status and addresses challenges in future perspectives. Graphical abstractRecent development and breakthrough points of lateral flow biosensors.
Collapse
Affiliation(s)
- Yan Huang
- Research Center for Bioengineering and Sensing Technology, University of Science & Technology Beijing, Beijing, 100083, People's Republic of China.,Institute of Biomedical and Health, School of Life and Health Science, Anhui Science and Technology University, Fengyang, Anhui, 233100, People's Republic of China.,Department of Chemistry and biochemistry, North Dakota State University, Fargo, ND, 58105, USA
| | - Tailin Xu
- Research Center for Bioengineering and Sensing Technology, University of Science & Technology Beijing, Beijing, 100083, People's Republic of China
| | - Wenqian Wang
- Research Center for Bioengineering and Sensing Technology, University of Science & Technology Beijing, Beijing, 100083, People's Republic of China
| | - Yongqiang Wen
- Research Center for Bioengineering and Sensing Technology, University of Science & Technology Beijing, Beijing, 100083, People's Republic of China
| | - Kun Li
- Institute of Biomedical and Health, School of Life and Health Science, Anhui Science and Technology University, Fengyang, Anhui, 233100, People's Republic of China
| | - Lisheng Qian
- Institute of Biomedical and Health, School of Life and Health Science, Anhui Science and Technology University, Fengyang, Anhui, 233100, People's Republic of China.
| | - Xueji Zhang
- Research Center for Bioengineering and Sensing Technology, University of Science & Technology Beijing, Beijing, 100083, People's Republic of China. .,Institute of Biomedical and Health, School of Life and Health Science, Anhui Science and Technology University, Fengyang, Anhui, 233100, People's Republic of China. .,School of Biomedical Engineering, Shenzhen University Healthy Science Center, Shenzhen, Guangdong, 518060, People's Republic of China.
| | - Guodong Liu
- Institute of Biomedical and Health, School of Life and Health Science, Anhui Science and Technology University, Fengyang, Anhui, 233100, People's Republic of China. .,Department of Chemistry and biochemistry, North Dakota State University, Fargo, ND, 58105, USA.
| |
Collapse
|
39
|
A Critical Comparison between Flow-through and Lateral Flow Immunoassay Formats for Visual and Smartphone-Based Multiplex Allergen Detection. BIOSENSORS-BASEL 2019; 9:bios9040143. [PMID: 31842439 PMCID: PMC6956089 DOI: 10.3390/bios9040143] [Citation(s) in RCA: 33] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/03/2019] [Revised: 12/05/2019] [Accepted: 12/11/2019] [Indexed: 12/22/2022]
Abstract
(1) Background: The lack of globally standardized allergen labeling legislation necessitates consumer-focused multiplexed testing devices. These should be easy to operate, fast, sensitive and robust. (2) Methods: Herein, we describe the development of three different formats for multiplexed food allergen detection, namely active and passive flow-through assays, and lateral flow immunoassays with different test line configurations. (3) Results: The fastest assay time was 1 min, whereas even the slowest assay was within 10 min. With the passive flow approach, the limits of detection (LOD) of 0.1 and 0.5 ppm for total hazelnut protein (THP) and total peanut protein (TPP) in spiked buffer were reached, or 1 and 5 ppm of THP and TPP spiked into matrix. In comparison, the active flow approach reached LODs of 0.05 ppm for both analytes in buffer and 0.5 and 1 ppm of THP and TPP spiked into matrix. The optimized LFIA configuration reached LODs of 0.1 and 0.5 ppm of THP and TPP spiked into buffer or 0.5 ppm for both analytes spiked into matrix. The optimized LFIA was validated by testing in 20 different blank and spiked matrices. Using device-independent color space for smartphone analysis, two different smartphone models were used for the analysis of optimized assays.
Collapse
|
40
|
Rong Z, Bai Z, Li J, Tang H, Shen T, Wang Q, Wang C, Xiao R, Wang S. Dual-color magnetic-quantum dot nanobeads as versatile fluorescent probes in test strip for simultaneous point-of-care detection of free and complexed prostate-specific antigen. Biosens Bioelectron 2019; 145:111719. [PMID: 31563066 DOI: 10.1016/j.bios.2019.111719] [Citation(s) in RCA: 63] [Impact Index Per Article: 12.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2019] [Accepted: 09/19/2019] [Indexed: 12/22/2022]
Abstract
Simultaneous detection of free and complexed prostate-specific antigen (f-PSA and c-PSA) is critical to the prostate cancer (PCa) diagnostic accuracy for clinical samples with PSA values in the diagnostic gray zone between 4 and 10 ng mL-1. Herein, red and green magnetic-quantum dot nanobeads (MQBs) with superior magnetic property and high luminescence were fabricated via polyethyleneimine-mediated electrostatic adsorption of numerous quantum dots onto superparamagnetic Fe3O4 magnetic cores, and were conjugated with f-PSA antibody and c-PSA antibody, respectively, as versatile fluorescent probes in test strip for immune recognition, magnetic enrichment, and simultaneous detection of f-PSA and c-PSA analytes in complex biological matrix with t-PSA antibody on the test line. A low-cost and portable smartphone readout device with an application was also developed for the imaging of dual-color test strips and data processing. This assay can simultaneously detect f-PSA and c-PSA with the limits of detection of 0.009 ng mL-1 and 0.087 ng mL-1, respectively. Clinical serum samples of PCa and benign prostatic hyperplasia patients were evaluated to confirm the clinical feasibility. The results suggest that the proposed dual-color MQBs-based fluorescent lateral flow immunoassay is a promising point-of-care diagnostics technique for the accurate diagnosis of PCa even in resource-limited settings.
Collapse
Affiliation(s)
- Zhen Rong
- Beijing Institute of Radiation Medicine, Beijing, 100850, PR China; Beijing Key Laboratory of New Molecular Diagnosis Technologies for Infectious Diseases, Beijing, 100850, PR China
| | - Zikun Bai
- Beijing Institute of Radiation Medicine, Beijing, 100850, PR China; Beijing Key Laboratory of New Molecular Diagnosis Technologies for Infectious Diseases, Beijing, 100850, PR China
| | - Jianing Li
- Beijing Institute of Radiation Medicine, Beijing, 100850, PR China; Beijing Key Laboratory of New Molecular Diagnosis Technologies for Infectious Diseases, Beijing, 100850, PR China
| | - Hao Tang
- Department of Urology, Nanjing Jinling Hospital, Nanjing, 210002, PR China
| | - Tianyi Shen
- Department of Urology, Nanjing Jinling Hospital, Nanjing, 210002, PR China
| | - Qiong Wang
- Beijing Institute of Radiation Medicine, Beijing, 100850, PR China; Beijing Meiling Biotechnology Corporation, Beijing, 102600, PR China
| | - Chongwen Wang
- Beijing Institute of Radiation Medicine, Beijing, 100850, PR China; Beijing Key Laboratory of New Molecular Diagnosis Technologies for Infectious Diseases, Beijing, 100850, PR China; College of Life Sciences, Anhui Agricultural University, Hefei, 230036, PR China.
| | - Rui Xiao
- Beijing Institute of Radiation Medicine, Beijing, 100850, PR China; Beijing Key Laboratory of New Molecular Diagnosis Technologies for Infectious Diseases, Beijing, 100850, PR China.
| | - Shengqi Wang
- Beijing Institute of Radiation Medicine, Beijing, 100850, PR China; Beijing Key Laboratory of New Molecular Diagnosis Technologies for Infectious Diseases, Beijing, 100850, PR China.
| |
Collapse
|
41
|
Jiang N, Ahmed R, Damayantharan M, Ünal B, Butt H, Yetisen AK. Lateral and Vertical Flow Assays for Point-of-Care Diagnostics. Adv Healthc Mater 2019; 8:e1900244. [PMID: 31081270 DOI: 10.1002/adhm.201900244] [Citation(s) in RCA: 92] [Impact Index Per Article: 18.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2019] [Revised: 04/08/2019] [Indexed: 02/03/2023]
Abstract
Lateral flow assays (LFAs) have been the pillar of rapid point-of-care (POC) diagnostics due to their simplicity, rapid process, and low cost. Recent advances in sensitivity, selectivity, and chemical stability enhancement have ensured the foothold of LFAs in commercial POC diagnostics. This paper reviews recent developments in labeling strategies and detection methods of LFAs. Moreover, vertical flow assays (VFAs) have emerged as an alternate paper-based assay due to faster detection time and unique multiplexing capabilities. Smartphones as LFA readers have been transformed into a universal integrated platform for imaging, data processing, and storage, providing quantitative results in low-resource settings. Commercial LFAs and VFAs products are evaluated with regards to their performance, market trends, and regulatory issues. The future outlook of the flow-based assays for POC diagnostics is also discussed.
Collapse
Affiliation(s)
- Nan Jiang
- School of Engineering and Applied SciencesHarvard University Cambridge MA 02138 USA
| | - Rajib Ahmed
- School of MedicineStanford University Palo Alto CA 94304 USA
| | - Mylon Damayantharan
- School of EngineeringUniversity of Birmingham Edgbaston Birmingham B15 2TT UK
| | - Barış Ünal
- Triton Systems Inc. 200 Turnpike Rd. Chelmsford MA 01824 USA
| | - Haider Butt
- School of EngineeringUniversity of Birmingham Edgbaston Birmingham B15 2TT UK
| | - Ali K. Yetisen
- Department of Chemical EngineeringImperial College London London SW7 2AZ UK
| |
Collapse
|
42
|
Chen R, Liu B, Ni H, Chang N, Luan C, Ge Q, Dong J, Zhao X. Vertical flow assays based on core–shell SERS nanotags for multiplex prostate cancer biomarker detection. Analyst 2019; 144:4051-4059. [DOI: 10.1039/c9an00733d] [Citation(s) in RCA: 36] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
A core–shell SERS nanotag based VFA with a single test spot for multiplex biomarker detection at pg mL−1 level with a wide LDR.
Collapse
Affiliation(s)
- Ruipeng Chen
- State Key Laboratory of Bioelectronics
- School of Biological Science and Medical Engineering
- Southeast University
- Nanjing 210096
- China
| | - Bing Liu
- State Key Laboratory of Bioelectronics
- School of Biological Science and Medical Engineering
- Southeast University
- Nanjing 210096
- China
| | - Haibin Ni
- State Key Laboratory of Bioelectronics
- School of Biological Science and Medical Engineering
- Southeast University
- Nanjing 210096
- China
| | - Ning Chang
- State Key Laboratory of Bioelectronics
- School of Biological Science and Medical Engineering
- Southeast University
- Nanjing 210096
- China
| | - Chengxin Luan
- Department of Hematology and Oncology (Key Department of Jiangsu Medicine)
- Zhongda Hospital
- School of Medicine Southeast University
- Nanjing 210009
- China
| | - Qinyu Ge
- State Key Laboratory of Bioelectronics
- School of Biological Science and Medical Engineering
- Southeast University
- Nanjing 210096
- China
| | - Jian Dong
- State Key Laboratory of Bioelectronics
- School of Biological Science and Medical Engineering
- Southeast University
- Nanjing 210096
- China
| | - Xiangwei Zhao
- State Key Laboratory of Bioelectronics
- School of Biological Science and Medical Engineering
- Southeast University
- Nanjing 210096
- China
| |
Collapse
|