1
|
Zhang J, Li M, Li C, Lyu M, Xuan X, Li H. Electrochemical needle sensor based on a B, N co-doped graphene microelectrode array for the on-site detection of salicylic acid in fruits and vegetables. Food Chem 2024; 449:139264. [PMID: 38593724 DOI: 10.1016/j.foodchem.2024.139264] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2024] [Revised: 03/24/2024] [Accepted: 04/03/2024] [Indexed: 04/11/2024]
Abstract
In this study, a microelectrode array sensor based on boron and nitrogen co-doped vertical graphene (BNVG) was assembled to quantify salicylic acid (SA) in living plants. The influence of B and N contents on the electrochemical reaction kinetics and SA response signal was investigated. A microneedle sensor with three optimized BNVG microelectrodes (3.57 at.% B and 3.27 at.% N) was used to quantitatively analyze SA in the 0.5-100 μM concentration range and pH 4.0-9.0, with limits of detection of 0.14-0.18 μM. Additionally, a quantitative electrochemical model database based on the BNVG microelectrode sensor was constructed to monitor the growth of cucumbers and cauliflowers, which confirmed that the SA level and plant growth rate were positively correlated. Moreover, the SA levels in various vegetables and fruits purchased from the market were measured to demonstrate the practical application prospects for on-site inspection and evaluation.
Collapse
Affiliation(s)
- Jie Zhang
- Tianjin Key Laboratory of Film Electronic and Communication Devices, School of Integrated Circuit Science and Engineering, Tianjin University of Technology, Tianjin 300384, PR China
| | - Mingji Li
- Tianjin Key Laboratory of Film Electronic and Communication Devices, School of Integrated Circuit Science and Engineering, Tianjin University of Technology, Tianjin 300384, PR China.
| | - Cuiping Li
- Tianjin Key Laboratory of Film Electronic and Communication Devices, School of Integrated Circuit Science and Engineering, Tianjin University of Technology, Tianjin 300384, PR China
| | - Mingjie Lyu
- State Key Laboratory of Vegetable Biobreeding, Tianjin Academy of Agricultural Sciences, Tianjin 300192, China.
| | - Xiuwei Xuan
- Tianjin Key Laboratory of Film Electronic and Communication Devices, School of Integrated Circuit Science and Engineering, Tianjin University of Technology, Tianjin 300384, PR China
| | - Hongji Li
- Tianjin Key Laboratory of Organic Solar Cells and Photochemical Conversion, School of Chemistry and Chemical Engineering, Tianjin University of Technology, Tianjin 300384, PR China.
| |
Collapse
|
2
|
Han H, Ji Y, Zhao X, Yin L, Liu X, Sha J. MOFs@POMs-derived bimetallic oxide Fe 2(MoO 4) 3 nanoparticles for sensitive colorimetric detection of salicylic acid in aspirin. Mikrochim Acta 2024; 191:178. [PMID: 38443607 DOI: 10.1007/s00604-024-06261-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2023] [Accepted: 02/04/2024] [Indexed: 03/07/2024]
Abstract
A colorimetric sensing method for salicylic acid (SA) was developed by designing and fabricating bimetallic oxide nanozymes. Firstly, by calcinating MIL-100(Fe)@PMo12 (MOFs@POMs) at different temperature, Fe2(MoO4)3-Ts (T = 400℃, 500℃, 600℃, 700℃) nanoparticles (NPs) were successfully prepared. Secondly, by evaluating the peroxidase-like activities, Fe2(MoO4)3-600 NPs shows the best peroxidase-like activity attributed to the Fenton-like effect and the synergistic coupling interaction between Mo and Fe. Finally, based on the specific complexation between SA and Fe3+, a sensitive colorimetric sensor for SA was established, which exhibits superior selectivity and interference with a detection limit of 0.11 μM and a linear range of 10 to 100 μM, the lowest LOD for SA to date, to the best of our knowledge.
Collapse
Affiliation(s)
- Hong Han
- School of Chemistry, Chemical Engineering and Materials, Jining University, Qufu, 273155, People's Republic of China
| | - Yuhan Ji
- School of Chemistry, Chemical Engineering and Materials, Jining University, Qufu, 273155, People's Republic of China
- School of Pharmacy, Jiamusi University, Jiamusi, 154007, People's Republic of China
| | - Xin Zhao
- Department of Pharmacy, Boshan District Hospital, Boshan, 255200, People's Republic of China
| | - Ling Yin
- School of Chemistry, Chemical Engineering and Materials, Jining University, Qufu, 273155, People's Republic of China
| | - Xiangyi Liu
- School of Chemistry, Chemical Engineering and Materials, Jining University, Qufu, 273155, People's Republic of China
- School of Pharmacy, Jiamusi University, Jiamusi, 154007, People's Republic of China
| | - Jingquan Sha
- School of Chemistry, Chemical Engineering and Materials, Jining University, Qufu, 273155, People's Republic of China.
- School of Pharmacy, Jiamusi University, Jiamusi, 154007, People's Republic of China.
| |
Collapse
|
3
|
Liu L, Chen M, Yuan L, Mi Z, Li C, Liu Z, Chen Z, Wang L, Feng F, Wu L. A novel ratiometric fluorescent probe based on dual-emission carbon dots for highly sensitive detection of salicylic acid. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2023; 303:123232. [PMID: 37562209 DOI: 10.1016/j.saa.2023.123232] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/27/2023] [Revised: 07/26/2023] [Accepted: 08/02/2023] [Indexed: 08/12/2023]
Abstract
In this study, a novel ratiometric fluorescence probe based on dual-emission carbon dots (CDs) for the sensitive detection of salicylic acid (SA) was constructed for the first time. The dual-emission CDs were synthesized by simple hydrothermal method using tartaric acid (TA) and m-phenylenediamine (mPD) as raw materials. In the presence of SA, the fluorescence intensity of CDs was enhanced at 499 nm, but remained basically unchanged at 439 nm. This phenomenon is caused by the intermolecular hydrogen bond interactions. The concentrations of SA had an excellent linear relationship with CDs' fluorescence intensity ratio (F499/F439) in a range of 1 ∼ 120 and 120 ∼ 240 μM with low detection limits of 0.68 and 1.05 μM. The established ratiometric fluorescent probe is economical, simple and green, and can be used for the effective detection of SA. In addition, the proposed ratiometric fluorescent probe was successfully used to monitor SA in facial mask and toning lotion samples with a satisfactory recovery of 99.7-106.7 %. The results show that the constructed fluorescent probe based on dual-emission CDs has a great potential for the rapid and sensitive analysis of SA in actual samples.
Collapse
Affiliation(s)
- Lizhen Liu
- Shanxi Datong University, Datong 037009, PR China
| | - Meng Chen
- Shanxi Datong University, Datong 037009, PR China
| | - Lin Yuan
- Shanxi Datong University, Datong 037009, PR China
| | - Zhi Mi
- Shanxi Datong University, Datong 037009, PR China.
| | - Caiqing Li
- Shanxi Datong University, Datong 037009, PR China
| | - Zhixiong Liu
- Shanxi Datong University, Datong 037009, PR China
| | - Zezhong Chen
- Shanxi Datong University, Datong 037009, PR China
| | - Ligang Wang
- Shanxi Datong University, Datong 037009, PR China
| | - Feng Feng
- Shanxi Datong University, Datong 037009, PR China; Shanxi Institute of Energy, Jinzhong 030600, PR China.
| | - Luqi Wu
- Quanzhou Normal University, Quanzhou 362000, PR China
| |
Collapse
|
4
|
Su T, Mi Z, Xia Y, Jin D, Xu Q, Hu X, Shu Y. A wearable sweat electrochemical aptasensor based on the Ni-Co MOF nanosheet-decorated CNTs/PU film for monitoring of stress biomarker. Talanta 2023; 260:124620. [PMID: 37148688 DOI: 10.1016/j.talanta.2023.124620] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2023] [Revised: 04/15/2023] [Accepted: 04/30/2023] [Indexed: 05/08/2023]
Abstract
Monitoring cortisol, a hormone released by the adrenal cortex in response to stress, is essential to evaluate the endocrine response to stress stimuli. While the current cortisol sensing methods require large laboratory settings, complex assay, and professional personnel. Herein, a novel flexible and wearable electrochemical aptasensor based on a Ni-Co metal-organic frameworks (MOF) nanosheet-decorated carbon nanotubes (CNTs)/polyurethane (PU) film is developed for rapid and reliable detection of cortisol in sweat. First, the CNTs/PU (CP) film was prepared by a modified wet spinning technology, and the CNTs/polyvinyl alcohol (PVA) solution was thermally deposited on the surface of CP film to form the highly flexible CNTs/PVA/CP (CCP) film with excellent conductivity. Then aminated Ni-Co MOF nanosheet prepared by a facile solvothermal method was conjugated with streptavidin and modified on the CCP film. Biofunctional MOF can effectively capture cortisol aptamer due to its excellent specific surface area. In addition, the MOF with peroxidase activity can catalytic oxidization of hydroquinone (HQ) by hydrogen peroxide (H2O2), which could amplify the peak current signal. The catalytic activity of Ni-Co MOF was substantially suppressed in the HQ/H2O2 system due to the formation of the aptamer-cortisol complex, which reduced the current signal, thereby realizing highly sensitive and selective detection of cortisol. The sensor has a linear range of 0.1-100 ng/mL and a detection limit of 0.032 ng/mL. Meanwhile, the sensor showed high accuracy for cortisol detection under mechanical deformation conditions. More importantly, the prepared MOF/CCP film based three-electrode was assembled with the polydimethylsiloxane (PDMS) substrate, and the sweat-cloth was used as the sweat collection channel to fabricate a wearable sensor patch for monitoring of cortisol in volunteers' sweat in the morning and evening. This flexible and non-invasive sweat cortisol aptasensor shows great potential for quantitative stress monitoring and management.
Collapse
Affiliation(s)
- Tong Su
- School of Chemistry and Chemical Engineering, Yangzhou University, Yangzhou 225002, PR China
| | - Ziyi Mi
- School of Chemistry and Chemical Engineering, Yangzhou University, Yangzhou 225002, PR China
| | - Youyuan Xia
- School of Chemistry and Chemical Engineering, Yangzhou University, Yangzhou 225002, PR China
| | - Dangqin Jin
- Department of Chemical Engineering, Yangzhou Polytechnic Institute, Yangzhou 225127, PR China
| | - Qin Xu
- School of Chemistry and Chemical Engineering, Yangzhou University, Yangzhou 225002, PR China
| | - Xiaoya Hu
- School of Chemistry and Chemical Engineering, Yangzhou University, Yangzhou 225002, PR China
| | - Yun Shu
- School of Chemistry and Chemical Engineering, Yangzhou University, Yangzhou 225002, PR China.
| |
Collapse
|
5
|
Tang Y, Yan J, Xiao W, Huang X, Tang L, Shi Y, Song P, Gao J. Stretchable, durable and asymmetrically wettable nanofiber composites with unidirectional water transportation capability for temperature sensing. J Colloid Interface Sci 2023; 641:893-902. [PMID: 36972624 DOI: 10.1016/j.jcis.2023.03.088] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2022] [Revised: 03/09/2023] [Accepted: 03/13/2023] [Indexed: 03/18/2023]
Abstract
The one-way transportation of liquids plays an important role in smart and wearable electronics. Here, we report an asymmetric nanofibrous membrane (ANM) with unidirectional water transport (UWT) capability by integrating one superhydrophilic MXene/Chitosan/Polyurethane (PU) nanofiber membrane (MCPNM) and one ultrathin hydrophobic PU/Polyvinylpyrrolidone (PVP) layer with a "bead-on-string" structure. The UWT performance shows long-term stability and can be well maintained during the cyclic stretching, abrasion and ultrasonic washing tests. The ANM exhibits negative temperature coefficient and is served as a temperature sensor to monitor the temperature variation of the environment, which can provide efficient alarm signals in a hot or cold condition. When attached on person's skin, the ANM displays a unique anti-gravity UWT behavior. The stretchable, wearable and multi-functional nanofibrous composite membrane with an asymmetric wettability shows potential applications in flexible and wearable electronics, health monitoring, etc.
Collapse
|
6
|
Shu Y, Shang Z, Su T, Zhang S, Lu Q, Xu Q, Hu X. A highly flexible Ni-Co MOF nanosheet coated Au/PDMS film based wearable electrochemical sensor for continuous human sweat glucose monitoring. Analyst 2022; 147:1440-1448. [PMID: 35262099 DOI: 10.1039/d1an02214h] [Citation(s) in RCA: 24] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
The development of flexible substrate materials and nanomaterials with high electrochemical performance is of great significance for constructing efficient wearable electrochemical sensors for real-time health monitoring. Herein, a wearable electrochemical sweat sensor based on a Ni-Co MOF nanosheet coated Au/polydimethylsiloxane (PDMS) film was prepared for continuous monitoring of the glucose level in sweat with high sensitivity. First, a stretchable Au/PDMS film based three-electrode system was prepared by chemical deposition of a gold layer on the hydrophilic treated PDMS. Then, Ni-Co MOF nanosheets with high electrocatalytic activity were synthesized by a facile solvothermal method and modified on the Au/PDMS electrode. The electrocatalytic activity of the Ni-Co MOF nanosheets synthesized under different Ni : Co ratios was investigated. The Ni-Co MOF/Au/PDMS (NCAP) film electrode showed excellent electrochemical performance for glucose detection with a wide linear range of 20 μM to 790 μM and a high sensitivity of 205.1 μA mM-1 cm-2. In addition, the flexible sensor shows high stability and a good electrochemical response to glucose when stretched and bent to different levels. Moreover, it maintained long-term stability and high selectivity for glucose monitoring. Lastly, a sweat-absorbent cloth was used to cover the working area of the sensor and was fixed with a needle and thread to form a wearable sweat glucose sensor. The sensor can be attached to the skin for stable, accurate and continuous monitoring of glucose levels in human sweat for one day. This work validates the potential of our high-performance wearable sensor for out-of-clinic health monitoring.
Collapse
Affiliation(s)
- Yun Shu
- School of Chemistry and Chemical Engineering, Yangzhou University, Yangzhou 225002, P.R. China.
| | - Zhenjiao Shang
- School of Chemistry and Chemical Engineering, Yangzhou University, Yangzhou 225002, P.R. China.
| | - Tong Su
- School of Chemistry and Chemical Engineering, Yangzhou University, Yangzhou 225002, P.R. China.
| | - Shenghao Zhang
- School of Chemistry and Chemical Engineering, Yangzhou University, Yangzhou 225002, P.R. China.
| | - Qin Lu
- School of Chemistry and Chemical Engineering, Yangzhou University, Yangzhou 225002, P.R. China.
| | - Qin Xu
- School of Chemistry and Chemical Engineering, Yangzhou University, Yangzhou 225002, P.R. China.
| | - Xiaoya Hu
- School of Chemistry and Chemical Engineering, Yangzhou University, Yangzhou 225002, P.R. China.
| |
Collapse
|
7
|
Shu Y, Su T, Lu Q, Shang Z, Xu Q, Hu X. Highly Stretchable Wearable Electrochemical Sensor Based on Ni-Co MOF Nanosheet-Decorated Ag/rGO/PU Fiber for Continuous Sweat Glucose Detection. Anal Chem 2021; 93:16222-16230. [PMID: 34813294 DOI: 10.1021/acs.analchem.1c04106] [Citation(s) in RCA: 64] [Impact Index Per Article: 21.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
A noninvasive fiber material-based wearable electrochemical sensor to continuously monitor the glucose level in sweat is highly desirable for smart fabrics for personal diabetes management. To achieve it, the key challenge is to construct fibers with high stretchability and excellent electrochemical performance. Herein, a highly stretchable Ni-Co metal-organic framework/Ag/reduced graphene oxide/polyurethane (Ni-Co MOF/Ag/rGO/PU) fiber-based wearable electrochemical sensor is fabricated for monitoring the glucose level in sweat continuously with high sensitivity and accuracy. The rGO/PU fiber was simply produced by an improved wet spinning technology, and the Ni-Co MOF nanosheet was coated on its surface to prepare the Ni-Co MOF/Ag/rGO/PU (NCGP) fiber electrode. The Ni-Co MOF has a large specific surface area and high catalytic activity, which enables the fiber sensors with good electrochemical performance with a high sensitivity of 425.9 μA·mM-1·cm-2 and a wide linear range of 10 μM-0.66 mM. More importantly, the NCGP fiber electrode also shows extremely high stretching and bending stability under mechanical deformation. Also, the NCGP fiber electrode has high selectivity and long-time storage stability. Moreover, the NCGP fiber-based three-electrode system was sewn with an absorbent fabric and fixed on a stretchable polydimethylsiloxane film substrate to form a nonenzymatic sweat glucose wearable sensor, which realized real-time monitoring of glucose in human sweat with high accuracy. This indicates that our designed NCGP fiber can be used as a wearable electrochemical sensor for the bio-diagnostics of body sweat.
Collapse
Affiliation(s)
- Yun Shu
- School of Chemistry and Chemical Engineering, Yangzhou University, Yangzhou 225002, P.R.China
| | - Tong Su
- School of Chemistry and Chemical Engineering, Yangzhou University, Yangzhou 225002, P.R.China
| | - Qin Lu
- School of Chemistry and Chemical Engineering, Yangzhou University, Yangzhou 225002, P.R.China
| | - Zhenjiao Shang
- School of Chemistry and Chemical Engineering, Yangzhou University, Yangzhou 225002, P.R.China
| | - Qin Xu
- School of Chemistry and Chemical Engineering, Yangzhou University, Yangzhou 225002, P.R.China
| | - Xiaoya Hu
- School of Chemistry and Chemical Engineering, Yangzhou University, Yangzhou 225002, P.R.China
| |
Collapse
|
8
|
Lu Q, Su T, Shang Z, Jin D, Shu Y, Xu Q, Hu X. Flexible paper-based Ni-MOF composite/AuNPs/CNTs film electrode for HIV DNA detection. Biosens Bioelectron 2021; 184:113229. [PMID: 33894427 DOI: 10.1016/j.bios.2021.113229] [Citation(s) in RCA: 49] [Impact Index Per Article: 16.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2021] [Revised: 03/18/2021] [Accepted: 04/03/2021] [Indexed: 02/07/2023]
Abstract
It is very important to develop a rapid, simple, low cost point-of-care (POC) method for the early diagnosis of pathogens. In this work, a flexible paper-based electrode based on nickel metal-organic framework (Ni-MOF) composite/Au nanoparticles/carbon nanotubes/polyvinyl alcohol (Ni-Au composite/CNT/PVA) was constructed to detect target human immunodeficiency virus (HIV) DNA by DNA hybridization using methylene blue (MB) as a redox indicator. The CNT/PVA and Ni-Au composite were deposited on the cellulose membrane by vacuum filtration and drop-coating method in turn to obtain Ni-Au composite/CNT/PVA (CCP) film electrode. Compared to the CNT/PVA film electrode, CCP film electrode makes a higher loading of the probe DNA for its large specific surface area and conjugated π-electron system that can provide hydrogen bond sources to achieve interactions between MOF and single-stranded DNA, which improves the sensitivity for detecting target DNA. The variation of peak current for MB molecules adsorbed onto DNA before and after hybridization with HIV DNA was monitored. Electrochemical results proved that the CCP film maintained stable electrochemical property even after bending 200 times or stretching under different strains from 0% to 20%. The flexible paper electrode showed excellent sensing performance with a linear range of 10 nM-1 μM and a low detection limit of 0.13 nM. The target HIV DNA was successfully detected even in complex serum samples using the flexible CCP film electrode. Therefore, the simple and inexpensive flexible paper-based MOF composite film electrode can also be utilized for other pathogens POC diagnosis.
Collapse
Affiliation(s)
- Qin Lu
- School of Chemistry and Chemical Engineering, Yangzhou University, Yangzhou, 225002, PR China
| | - Tong Su
- School of Chemistry and Chemical Engineering, Yangzhou University, Yangzhou, 225002, PR China
| | - Zhenjiao Shang
- School of Chemistry and Chemical Engineering, Yangzhou University, Yangzhou, 225002, PR China
| | - Dangqin Jin
- Department of Chemical Engineering, Yangzhou Polytechnic Institute, Yangzhou, 225127, PR China
| | - Yun Shu
- School of Chemistry and Chemical Engineering, Yangzhou University, Yangzhou, 225002, PR China.
| | - Qin Xu
- School of Chemistry and Chemical Engineering, Yangzhou University, Yangzhou, 225002, PR China
| | - Xiaoya Hu
- School of Chemistry and Chemical Engineering, Yangzhou University, Yangzhou, 225002, PR China.
| |
Collapse
|