Amendola C, Buttafava M, Carteano T, Contini L, Cortese L, Durduran T, Frabasile L, Guadagno CN, Karadeinz U, Lacerenza M, Mesquida J, Parsa S, Re R, Sanoja Garcia D, Konugolu Venkata Sekar S, Spinelli L, Torricelli A, Tosi A, Weigel UM, Yaqub MA, Zanoletti M, Contini D. Assessment of power spectral density of microvascular hemodynamics in skeletal muscles at very low and low-frequency via near-infrared diffuse optical spectroscopies. BIOMEDICAL OPTICS EXPRESS 2023; 14:5994-6015. [PMID: 38021143 PMCID: PMC10659778 DOI: 10.1364/boe.502618] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/07/2023] [Revised: 10/10/2023] [Accepted: 10/16/2023] [Indexed: 12/01/2023]
Abstract
In this work, we used a hybrid time domain near-infrared spectroscopy (TD-NIRS) and diffuse correlation spectroscopy (DCS) device to retrieve hemoglobin and blood flow oscillations of skeletal muscle microvasculature. We focused on very low (VLF) and low-frequency (LF) oscillations (i.e., frequency lower than 0.145 Hz), that are related to myogenic, neurogenic and endothelial activities. We measured power spectral density (PSD) of blood flow and hemoglobin concentration in four muscles (thenar eminence, plantar fascia, sternocleidomastoid and forearm) of 14 healthy volunteers to highlight possible differences in microvascular hemodynamic oscillations. We observed larger PSDs for blood flow compared to hemoglobin concentration, in particular in case of distal muscles (i.e., thenar eminence and plantar fascia). Finally, we compared the PSDs measured on the thenar eminence of healthy subjects with the ones measured on a septic patient in the intensive care unit: lower power in the endothelial-dependent frequency band, and larger power in the myogenic ones were observed in the septic patient, in accordance with previous works based on laser doppler flowmetry.
Collapse
Affiliation(s)
| | | | | | | | - Lorenzo Cortese
- ICFO - Institut de Ciències Fotòniques, The Barcelona Institute of Science and Technology, Castelldefels (Barcelona), Spain
| | - Turgut Durduran
- ICFO - Institut de Ciències Fotòniques, The Barcelona Institute of Science and Technology, Castelldefels (Barcelona), Spain
- Institució Catalana de Recerca i Estudis Avançats (ICREA), Barcelona, Spain
| | | | - Claudia Nunzia Guadagno
- BioPixS Ltd – Biophotonics Standards, IPIC, Tyndall National Institute, Lee Maltings Complex, Cork, Ireland
| | - Umut Karadeinz
- ICFO - Institut de Ciències Fotòniques, The Barcelona Institute of Science and Technology, Castelldefels (Barcelona), Spain
| | | | - Jaume Mesquida
- Critical Care Department, Parc Taulí Hospital Universitari. Institut D’Investigació i Innovació Parc Taulí I3PT, Sabadell, Spain
| | | | - Rebecca Re
- Dipartimento di Fisica, Politecnico di Milano, Milan, Italy
- Istituto di Fotonica e Nanotecnologie, Consiglio Nazionale delle Ricerche, Milano, Italy
| | | | | | - Lorenzo Spinelli
- Istituto di Fotonica e Nanotecnologie, Consiglio Nazionale delle Ricerche, Milano, Italy
| | - Alessandro Torricelli
- Dipartimento di Fisica, Politecnico di Milano, Milan, Italy
- Istituto di Fotonica e Nanotecnologie, Consiglio Nazionale delle Ricerche, Milano, Italy
| | - Alberto Tosi
- Politecnico di Milano, Dipartimento di Elettronica, Informazione e Bioingegneria, Milan, Italy
| | - Udo M. Weigel
- HemoPhotonics S.L., Castelldefels, (Barcelona), Spain
| | - M. Atif Yaqub
- ICFO - Institut de Ciències Fotòniques, The Barcelona Institute of Science and Technology, Castelldefels (Barcelona), Spain
| | - Marta Zanoletti
- ICFO - Institut de Ciències Fotòniques, The Barcelona Institute of Science and Technology, Castelldefels (Barcelona), Spain
| | - Davide Contini
- Dipartimento di Fisica, Politecnico di Milano, Milan, Italy
| |
Collapse
|
2
|
Zhou X, Xia Y, Uchitel J, Collins-Jones L, Yang S, Loureiro R, Cooper RJ, Zhao H. Review of recent advances in frequency-domain near-infrared spectroscopy technologies [Invited]. BIOMEDICAL OPTICS EXPRESS 2023; 14:3234-3258. [PMID: 37497520 PMCID: PMC10368025 DOI: 10.1364/boe.484044] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/19/2022] [Revised: 04/29/2023] [Accepted: 05/25/2023] [Indexed: 07/28/2023]
Abstract
Over the past several decades, near-infrared spectroscopy (NIRS) has become a popular research and clinical tool for non-invasively measuring the oxygenation of biological tissues, with particular emphasis on applications to the human brain. In most cases, NIRS studies are performed using continuous-wave NIRS (CW-NIRS), which can only provide information on relative changes in chromophore concentrations, such as oxygenated and deoxygenated hemoglobin, as well as estimates of tissue oxygen saturation. Another type of NIRS known as frequency-domain NIRS (FD-NIRS) has significant advantages: it can directly measure optical pathlength and thus quantify the scattering and absorption coefficients of sampled tissues and provide direct measurements of absolute chromophore concentrations. This review describes the current status of FD-NIRS technologies, their performance, their advantages, and their limitations as compared to other NIRS methods. Significant landmarks of technological progress include the development of both benchtop and portable/wearable FD-NIRS technologies, sensitive front-end photonic components, and high-frequency phase measurements. Clinical applications of FD-NIRS technologies are discussed to provide context on current applications and needed areas of improvement. The review concludes by providing a roadmap toward the next generation of fully wearable, low-cost FD-NIRS systems.
Collapse
Affiliation(s)
- Xinkai Zhou
- HUB of Intelligent Neuro-engineering (HUBIN), Aspire CREATe, IOMS, Division of Surgery and Interventional Science, University College London (UCL), London, HA7 4LP, UK
| | - Yunjia Xia
- HUB of Intelligent Neuro-engineering (HUBIN), Aspire CREATe, IOMS, Division of Surgery and Interventional Science, University College London (UCL), London, HA7 4LP, UK
- DOT-HUB, Department of Medical Physics & Biomedical Engineering, UCL, London, WC1E 6BT, UK
| | - Julie Uchitel
- Department of Paediatrics, University of Cambridge, Cambridge, CB2 0QQ, UK
| | - Liam Collins-Jones
- DOT-HUB, Department of Medical Physics & Biomedical Engineering, UCL, London, WC1E 6BT, UK
| | - Shufan Yang
- HUB of Intelligent Neuro-engineering (HUBIN), Aspire CREATe, IOMS, Division of Surgery and Interventional Science, University College London (UCL), London, HA7 4LP, UK
- School of Computing, Engineering & Build Environment, Edinburgh Napier University, Edinburgh, UK
| | - Rui Loureiro
- Aspire CREATe, Department of Orthopaedics & Musculoskeletal Science, UCL, London, HA7 4LP, UK
| | - Robert J. Cooper
- DOT-HUB, Department of Medical Physics & Biomedical Engineering, UCL, London, WC1E 6BT, UK
| | - Hubin Zhao
- HUB of Intelligent Neuro-engineering (HUBIN), Aspire CREATe, IOMS, Division of Surgery and Interventional Science, University College London (UCL), London, HA7 4LP, UK
- DOT-HUB, Department of Medical Physics & Biomedical Engineering, UCL, London, WC1E 6BT, UK
| |
Collapse
|
3
|
Age-Related Changes in Skeletal Muscle Oxygen Utilization. J Funct Morphol Kinesiol 2022; 7:jfmk7040087. [PMID: 36278748 PMCID: PMC9590092 DOI: 10.3390/jfmk7040087] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/25/2022] [Revised: 09/07/2022] [Accepted: 09/08/2022] [Indexed: 11/17/2022] Open
Abstract
The cardiovascular and skeletal muscle systems are intrinsically interconnected, sharing the goal of delivering oxygen to metabolically active tissue. Deficiencies within those systems that affect oxygen delivery to working tissues are a hallmark of advancing age. Oxygen delivery and utilization are reflected as muscle oxygen saturation (SmO2) and are assessed using near-infrared resonance spectroscopy (NIRS). SmO2 has been observed to be reduced by ~38% at rest, ~24% during submaximal exercise, and ~59% during maximal exercise with aging (>65 y). Furthermore, aging prolongs restoration of SmO2 back to baseline by >50% after intense exercise. Regulatory factors that contribute to reduced SmO2 with age include blood flow, capillarization, endothelial cells, nitric oxide, and mitochondrial function. These mechanisms are governed by reactive oxygen species (ROS) at the cellular level. However, mishandling of ROS with age ultimately leads to alterations in structure and function of the regulatory factors tasked with maintaining SmO2. The purpose of this review is to provide an update on the current state of the literature regarding age-related effects in SmO2. Furthermore, we attempt to bridge the gap between SmO2 and associated underlying mechanisms affected by aging.
Collapse
|
4
|
Giovannella M, Urtane E, Zanoletti M, Karadeniz U, Rubins U, Weigel UM, Marcinkevics Z, Durduran T. Microvascular blood flow changes of the abductor pollicis brevis muscle during sustained static exercise. BIOMEDICAL OPTICS EXPRESS 2021; 12:4235-4248. [PMID: 34457411 PMCID: PMC8367267 DOI: 10.1364/boe.427885] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/20/2021] [Revised: 06/09/2021] [Accepted: 06/09/2021] [Indexed: 06/13/2023]
Abstract
A practical assessment of the general health and microvascular function of the palm muscle, abductor pollicis brevis (APB), is important for the diagnosis of different conditions. In this study, we have developed a protocol and a probe to study microvascular blood flow using near-infrared diffuse correlation spectroscopy (DCS) in APB during and after thumb abduction at 55% of maximum voluntary contraction (MVC). Near-infrared time resolved spectroscopy (TRS) was also used to characterize the baseline optical and hemodynamic properties. Thirteen (n=13) subjects were enrolled and subdivided in low MVC (N=6, MVC<2.3 kg) and high MVC (N=7, MVC≥2.3 kg) groups. After ruling out significant changes in the systemic physiology that influence the muscle hemodynamics, we have observed that the high MVC group showed a 56% and 36% decrease in the blood flow during exercise, with respect to baseline, in the long and short source-detector (SD) separations (p=0.031 for both). No statistical differences were shown for the low MVC group (p=1 for short and p=0.15 for long SD). These results suggest that the mechanical occlusion, due to increased intramuscular pressure, exceeded the vasodilation elicited by the higher metabolic demand. Also, blood flow changes during thumb contraction negatively correlated (R=-0.7, p<0.01) with the absolute force applied by each subject. Furthermore, after the exercise, muscular blood flow increased significantly immediately after thumb contractions in both high and low MVC groups, with respect to the recorded values during the exercise (p=0.031). An increase of 251% (200%) was found for the long (short) SD in the low MVC group. The high MVC groups showed a significant 90% increase in blood flow only after 80 s from the start of the protocol. For both low and high MVC groups, blood flow recovered to baseline values within 160 s from starting the exercise. In conclusion, DCS allows the study of the response of a small muscle to static exercise and can be potentially used in multiple clinical conditions scenarios for assessing microvascular health.
Collapse
Affiliation(s)
- Martina Giovannella
- ICFO-Institut de Ciències Fotòniques, The Barcelona Institute of Science and Technology, 08860 Castelldefels (Barcelona), Spain
| | - Evelina Urtane
- Faculty of Biology, Department of Human and Animal Physiology, University of Latvia, Kronvalda Blvd. 4, LV 1586, Riga, Latvia
| | - Marta Zanoletti
- ICFO-Institut de Ciències Fotòniques, The Barcelona Institute of Science and Technology, 08860 Castelldefels (Barcelona), Spain
| | - Umut Karadeniz
- ICFO-Institut de Ciències Fotòniques, The Barcelona Institute of Science and Technology, 08860 Castelldefels (Barcelona), Spain
| | - Uldis Rubins
- Institute of Atomic Physics and Spectroscopy, University of Latvia, 19 Rainis Blvd., Riga LV- 1586, Latvia
| | - Udo M. Weigel
- HemoPhotonics S.L., Av. Carl Friedrich Gauss Num. 3, 08860 Castelldefels (Barcelona), Spain
| | - Zbignevs Marcinkevics
- Faculty of Biology, Department of Human and Animal Physiology, University of Latvia, Kronvalda Blvd. 4, LV 1586, Riga, Latvia
| | - Turgut Durduran
- ICFO-Institut de Ciències Fotòniques, The Barcelona Institute of Science and Technology, 08860 Castelldefels (Barcelona), Spain
- Institució Catalana de Recerca i Estudis Avançats (ICREA), 08010 Barcelona, Spain
| |
Collapse
|
5
|
Binzoni T, Martelli F, Cimasoni D. Topological complexity of photons' paths in biological tissues. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA. A, OPTICS, IMAGE SCIENCE, AND VISION 2019; 36:1883-1891. [PMID: 31873704 DOI: 10.1364/josaa.36.001883] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/17/2019] [Accepted: 10/03/2019] [Indexed: 06/10/2023]
Abstract
In the present contribution, three means of measuring the geometrical and topological complexity of photons' paths in random media are proposed. This is realized by investigating the behavior of the average crossing number, the mean writhe, and the minimal crossing number of photons' paths generated by Monte Carlo (MC) simulations, for different sets of optical parameters. It is observed that the complexity of the photons' paths increases for increasing light source/detector spacing, and that highly "knotted" paths are formed. Due to the particular rules utilized to generate the MC photons' paths, the present results may have an interest not only for the biomedical optics community, but also from a pure mathematical point of view.
Collapse
|
6
|
Hammer SM, Hueber DM, Townsend DK, Huckaby LM, Alexander AM, Didier KD, Barstow TJ. Effect of assuming constant tissue scattering on measured tissue oxygenation values during tissue ischemia and vascular reperfusion. J Appl Physiol (1985) 2019; 127:22-30. [DOI: 10.1152/japplphysiol.01138.2018] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
The purpose of this study was to determine the effects of assuming constant tissue scattering properties on tissue oxygenation measurements during a vascular occlusion test (VOT). Twenty-one subjects (21.8 ± 1.9 yr) completed a VOT [1 min baseline (BL), 5 min of tissue ischemia (TI), and 3 min of vascular reperfusion (VR)]. Absolute concentrations of oxygenated heme (oxy-[heme]), deoxygenated heme (deoxy-[heme]), total heme (total [heme), tissue oxygen saturation (StO2), and heme difference [heme]diff) were measured using frequency domain near-infrared spectroscopy (FD-NIRS) while 1) continuously measuring and incorporating tissue scattering ([Formula: see text]) and 2) assuming scattering remained constant. FD-NIRS measured [Formula: see text] increased during TI at 692 nm ( P < 0.001) and decreased at 834 nm ( P < 0.001). During VR, [Formula: see text] decreased at 692 nm ( P < 0.001) and increased at 834 nm ( P < 0.001). When assuming constant scattering, oxy-[heme] was significantly less at TIpeak ( P < 0.05) while deoxy-[heme] and StO2 were significantly altered at BL, TIpeak, and VRpeak (all P < 0.001). Total [heme] did not change during the VOT. Absolute changes in deoxy-[heme], oxy-[heme], and StO2 in response to TI and VR were significantly exaggerated (all P < 0.001) and the rates of change during TI ( slope 1) and VR ( slope 2) in deoxy-[heme], oxy-[heme], StO2, and [heme]diff were significantly increased (all P < 0.05) when constant tissue scattering was assumed. These findings demonstrate the need for caution when interpreting NIRS data without continuously measuring tissue optical properties. Further, assuming tissue optical properties remain constant may have important consequences to experimental data and clinical conclusions made using NIRS. NEW & NOTEWORTHY NIRS measurements provide significant experimental and clinical insight. We demonstrate that absolute changes in tissue oxygenation measurements made with NIRS are overestimated and the kinetic responses of NIRS measurements are exaggerated by varying degrees among individuals if tissue scattering characteristics are assumed to remain constant during vascular occlusion tests.
Collapse
Affiliation(s)
- Shane M. Hammer
- Department of Kinesiology, Kansas State University, Manhattan Kansas
| | | | | | - Lillie M. Huckaby
- Department of Kinesiology, Kansas State University, Manhattan Kansas
| | | | - Kaylin D. Didier
- Department of Kinesiology, Kansas State University, Manhattan Kansas
| | - Thomas J. Barstow
- Department of Kinesiology, Kansas State University, Manhattan Kansas
| |
Collapse
|
7
|
Behera A, Di Sieno L, Pifferi A, Martelli F, Mora AD. Instrumental, optical and geometrical parameters affecting time-gated diffuse optical measurements: a systematic study. BIOMEDICAL OPTICS EXPRESS 2018; 9:5524-5542. [PMID: 30460145 PMCID: PMC6238916 DOI: 10.1364/boe.9.005524] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/05/2018] [Revised: 08/23/2018] [Accepted: 09/09/2018] [Indexed: 05/23/2023]
Abstract
In time-domain diffuse optics the sensitivity to localized absorption changes buried inside a diffusive medium depends strongly on the interplay between instrumental, optical and geometrical parameters, which can hinder the theoretical advantages of novel measurement strategies like the short source-detector distance approach. Here, we present a study based on experimental measurements and simulations to comprehensively evaluate the effect of all different parameters. Results are evaluated exploiting standardized figures of merit, like contrast and contrast-to-noise ratio, to quantify the system sensitivity to deep localized absorption perturbations. Key findings show that the most critical hardware parameter is the memory effect which ultimately limits the dynamic range. Further, a choice of the source-detector distance around 10 mm seems to be a good compromise to compensate non-idealities in practical systems still preserving the advantages of short distances. This work provides both indications for users about the best measurement conditions and strategies, and for technology developers to identify the most crucial hardware features in view of next generation diffuse optics systems.
Collapse
Affiliation(s)
- Anurag Behera
- Politecnico di Milano, Dipartimento di Fisica, Piazza Leonardo da Vinci 32, 20133 Milano, Italy
| | - Laura Di Sieno
- Politecnico di Milano, Dipartimento di Fisica, Piazza Leonardo da Vinci 32, 20133 Milano, Italy
| | - Antonio Pifferi
- Politecnico di Milano, Dipartimento di Fisica, Piazza Leonardo da Vinci 32, 20133 Milano, Italy
- Consiglio Nazionale delle Ricerche, Istituto di Fotonica e Nanotecnologie, Piazza Leonardo da Vinci 32, 20133 Milano, Italy
| | - Fabrizio Martelli
- Università degli Studi di Firenze, Dipartimento di Fisica e Astronomia, Via G. Sansone 1, 50019 Sesto Fiorentino, Firenze, Italy
| | - Alberto Dalla Mora
- Politecnico di Milano, Dipartimento di Fisica, Piazza Leonardo da Vinci 32, 20133 Milano, Italy
| |
Collapse
|
8
|
Re R, Pirovano I, Contini D, Spinelli L, Torricelli A. Time Domain Near Infrared Spectroscopy Device for Monitoring Muscle Oxidative Metabolism: Custom Probe and In Vivo Applications. SENSORS 2018; 18:s18010264. [PMID: 29342097 PMCID: PMC5795927 DOI: 10.3390/s18010264] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/16/2017] [Revised: 01/09/2018] [Accepted: 01/15/2018] [Indexed: 11/26/2022]
Abstract
Measurement of muscle oxidative metabolism is of interest for monitoring the training status in athletes and the rehabilitation process in patients. Time domain near infrared spectroscopy (TD NIRS) is an optical technique that allows the non-invasive measurement of the hemodynamic parameters in muscular tissue: concentrations of oxy- and deoxy-hemoglobin, total hemoglobin content, and tissue oxygen saturation. In this paper, we present a novel TD NIRS medical device for muscle oxidative metabolism. A custom-printed 3D probe, able to host optical elements for signal acquisition from muscle, was develop for TD NIRS in vivo measurements. The system was widely characterized on solid phantoms and during in vivo protocols on healthy subjects. In particular, we tested the in vivo repeatability of the measurements to quantify the error that we can have by repositioning the probe. Furthermore, we considered a series of acquisitions on different muscles that were not yet previously performed with this custom probe: a venous-arterial cuff occlusion of the arm muscle, a cycling exercise, and an isometric contraction of the vastus lateralis.
Collapse
Affiliation(s)
- Rebecca Re
- Dipartimento di Fisica, Politecnico di Milano, Piazza Leonardo da Vinci, 32, 20133 Milan, Italy.
| | - Ileana Pirovano
- Dipartimento di Fisica, Politecnico di Milano, Piazza Leonardo da Vinci, 32, 20133 Milan, Italy.
| | - Davide Contini
- Dipartimento di Fisica, Politecnico di Milano, Piazza Leonardo da Vinci, 32, 20133 Milan, Italy.
| | - Lorenzo Spinelli
- Istituto di Fotonica e Nanotecnologie, Consiglio Nazionale delle Ricerche, Piazza Leonardo da Vinci, 32, 20133 Milan, Italy.
| | - Alessandro Torricelli
- Dipartimento di Fisica, Politecnico di Milano, Piazza Leonardo da Vinci, 32, 20133 Milan, Italy.
- Istituto di Fotonica e Nanotecnologie, Consiglio Nazionale delle Ricerche, Piazza Leonardo da Vinci, 32, 20133 Milan, Italy.
| |
Collapse
|
9
|
Warren RV, Cotter J, Ganesan G, Le L, Agustin JP, Duarte B, Cutler K, O’Sullivan T, Tromberg BJ. Noninvasive optical imaging of resistance training adaptations in human muscle. JOURNAL OF BIOMEDICAL OPTICS 2017; 22:1-9. [PMID: 29264896 PMCID: PMC5741457 DOI: 10.1117/1.jbo.22.12.121611] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/25/2017] [Accepted: 12/05/2017] [Indexed: 05/12/2023]
Abstract
A quantitative and dynamic analysis of skeletal muscle structure and function can guide training protocols and optimize interventions for rehabilitation and disease. While technologies exist to measure body composition, techniques are still needed for quantitative, long-term functional imaging of muscle at the bedside. We evaluate whether diffuse optical spectroscopic imaging (DOSI) can be used for long-term assessment of resistance training (RT). DOSI measures of tissue composition were obtained from 12 adults before and after 5 weeks of training and compared to lean mass fraction (LMF) from dual-energy X-ray absorptiometry (DXA). Significant correlations were detected between DXA LMF and DOSI-measured oxy-hemo/myoglobin, deoxy-hemo/myoglobin, total-hemo/myoglobin, water, and lipid. RT-induced increases of ∼6% in oxy-hemo/myoglobin (3.4±1.0 μM, p=0.00314) and total-hemo/myoglobin (4.9±1.1 μM, p=0.00024) from the medial gastrocnemius were detected with DOSI and accompanied by ∼2% increases in lean soft tissue mass (36.4±12.4 g, p=0.01641) and ∼60% increases in 1 rep-max strength (41.5±6.2 kg, p=1.9E-05). DOSI measures of vascular and/or muscle changes combined with correlations between DOSI and DXA suggest that quantitative diffuse optical methods can be used to evaluate body composition, provide feedback on long-term interventions, and generate new insight into training-induced muscle adaptations.
Collapse
Affiliation(s)
- Robert V. Warren
- University of California, Beckman Laser Institute and Medical Clinic, Irvine, California, United States
| | - Joshua Cotter
- California State University–Long Beach, Department of Kinesiology, Long Beach, California, United States
| | - Goutham Ganesan
- University of California, Beckman Laser Institute and Medical Clinic, Irvine, California, United States
| | - Lisa Le
- University of California, Institute for Clinical and Translational Science, Irvine, California, United States
| | - Janelle P. Agustin
- University of California, Institute for Clinical and Translational Science, Irvine, California, United States
| | - Bridgette Duarte
- University of California, Institute for Clinical and Translational Science, Irvine, California, United States
| | - Kyle Cutler
- University of California, Beckman Laser Institute and Medical Clinic, Irvine, California, United States
| | - Thomas O’Sullivan
- University of Notre Dame, Department of Electrical Engineering, Notre Dame, Indiana, United States
| | - Bruce J. Tromberg
- University of California, Beckman Laser Institute and Medical Clinic, Irvine, California, United States
- Address all correspondence to: Bruce J. Tromberg, E-mail:
| |
Collapse
|
10
|
Binzoni T, Martelli F. Study on the mathematical relationship existing between single-photon laser-Doppler flowmetry and diffuse correlation spectroscopy with static background. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA. A, OPTICS, IMAGE SCIENCE, AND VISION 2017; 34:2096-2101. [PMID: 29240082 DOI: 10.1364/josaa.34.002096] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/06/2017] [Accepted: 10/10/2017] [Indexed: 06/07/2023]
Abstract
In the present contribution, the theoretical relationship existing between the blood flow index measured by diffuse correlation spectroscopy and single-photon laser-Doppler flowmetry (SP-LDF) is investigated. A specific mathematical description that accounts for the properties of single-photon detectors for SP-LDP was developed. Static background has also been considered and, to the best of our knowledge, this has never been included before in SP-LDF analytical theories. The comparisons were realized for two SP-LDF implementations: for "classical" and "fast" algorithms. "Classical" SP-LDF is not sensitive to small changes on the number of detected speckles and coherence length of the laser, usually described by a unique parameter "beta." This is a strong point when assessing blood flow index, e.g., in humans, where "beta" is particularly difficult to be determined in real time. The proposed theory may be utilized, e.g., to investigate other SP-LDF setups and optical/physiological parameter ranges or, generally, to optimize real SP-LDF instrumentation.
Collapse
|
11
|
Binzoni T, Sanguinetti B, Van de Ville D, Zbinden H, Martelli F. Probability density function of the electric field in diffuse correlation spectroscopy of human bone in vivo. APPLIED OPTICS 2016; 55:757-62. [PMID: 26836077 DOI: 10.1364/ao.55.000757] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
Diffuse correlation spectroscopy (DCS) is the technique of choice for non-invasive assessments of human bone blood flow. However, DCS classical algorithms are based on the fundamental assumption that the electric field of the light reaching the DCS photodetector is a zero-mean complex Gaussian variable. The non-validity of this hypothesis might produce inaccurate blood flow estimations. It is shown that for the human tibia, the "Gaussian hypothesis" holds for interoptode distances ≥20 mm. This lower boundary seems to depend on the type of investigated tissue.
Collapse
|
12
|
Torricelli A, Contini D, Pifferi A, Caffini M, Re R, Zucchelli L, Spinelli L. Time domain functional NIRS imaging for human brain mapping. Neuroimage 2014; 85 Pt 1:28-50. [DOI: 10.1016/j.neuroimage.2013.05.106] [Citation(s) in RCA: 294] [Impact Index Per Article: 29.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2013] [Revised: 04/25/2013] [Accepted: 05/21/2013] [Indexed: 02/02/2023] Open
|
13
|
Horiuchi M, Fadel PJ, Ogoh S. Differential effect of sympathetic activation on tissue oxygenation in gastrocnemius and soleus muscles during exercise in humans. Exp Physiol 2013; 99:348-58. [PMID: 24163424 DOI: 10.1113/expphysiol.2013.075846] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
NEW FINDINGS What is the central question of this study? The normal ability of sympathetic nerves to cause vasoconstriction is blunted in exercising skeletal muscle, a phenomenon termed 'functional sympatholysis'. Animal studies suggest that functional sympatholysis appears to occur preferentially in fast-twitch type II glycolytic compared with slow-twitch type I oxidative skeletal muscle. We asked whether these findings can be extended to humans. What is the main finding and its importance? We show that skeletal muscles composed largely of fast-twitch type II fibres may also be more sensitive to functional sympatholysis in humans, particularly at lower exercise intensities. Additionally, independent of muscle fibre type composition, the magnitude of sympatholysis is strongly related to exercise-induced increases in metabolic demand. Animal studies suggest that functional sympatholysis appears to occur preferentially in glycolytic (largely type II) compared with oxidative (largely type I) skeletal muscle. Whether these findings can be extended to humans currently remains unclear. In 12 healthy male subjects, vasoconstrictor responses in gastrocnemius (i.e. primarily type II) and soleus muscles (i.e. primarily type I) were measured using near-infrared spectroscopy to detect decreases in muscle oxygenation (HbO(2)) in response to sympathetic activation evoked by a cold pressor test (CPT). The HbO(2) responses to a CPT at rest were compared with responses during steady-state plantar flexion exercise (30 repetitions min(-1)) performed at 10, 20 and 40% maximal voluntary contraction (MVC) for 6 min. In resting conditions, HbO(2) at the gastrocnemius (-14 ± 1%) and soleus muscles (-16 ± 1%) decreased significantly during CPT, with no differences between muscles. During planter flexion at 20% MVC, the change in HbO(2) in response to the CPT was blunted in gastrocnemius but not soleus, whereas during 40% MVC both muscles exhibited a significant attenuation to sympathetic activation. The decreases in HbO(2) in response to the CPT during exercise were significantly correlated with the metabolic demands of exercise (the decreases in HbO(2) in response to steady-state plantar flexion) in both gastrocnemius and soleus muscles. Collectively, these results suggest that skeletal muscles composed mainly of glycolytic type II fibres are more sensitive to functional sympatholysis, particularly at lower intensities of exercise. Moreover, the blunting of sympathetic vasoconstriction during exercise is strongly related to metabolic demand; an effect that appears independent of fibre type composition.
Collapse
Affiliation(s)
- Masahiro Horiuchi
- * Department of Biomedical Engineering, Toyo University, Kujirai 2100, Kawagoe City, Saitama 350-8585, Japan.
| | | | | |
Collapse
|
14
|
Bland E, Dréau D, Burg KJL. Overcoming hypoxia to improve tissue-engineering approaches to regenerative medicine. J Tissue Eng Regen Med 2012; 7:505-14. [PMID: 22761177 DOI: 10.1002/term.540] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2011] [Revised: 08/11/2011] [Accepted: 11/03/2011] [Indexed: 12/23/2022]
Abstract
The current clinical successes of tissue engineering are limited primarily to low-metabolism, acellular, pre-vascularized or thin tissues. Mass transport has been identified as the primary culprit, limiting the delivery of nutrients (such as oxygen and glucose) and removal of wastes, from tissues deep within a cellular scaffold. While strategies to develop sufficient vasculature to overcome hypoxia in vitro are promising, inconsistencies between the in vitro and the in vivo environments may still negate the effectiveness of large-volume tissue-engineered scaffolds. While a common theme in tissue engineering is to maximize oxygen supply, studies suggest that moderate oxygenation of cellular scaffolds during in vitro conditioning is preferable to high oxygen levels. Aiming for moderate oxygen values to prevent hypoxia while still promoting angiogenesis may be obtained by tailoring in vitro culture conditions to the oxygen environment the scaffold will experience upon implantation. This review discusses the causes and effects of tissue-engineering hypoxia and the optimization of oxygenation for the minimization of in vivo hypoxia.
Collapse
Affiliation(s)
- Erik Bland
- Department of Bioengineering, Clemson University, SC 29634, USA
| | | | | |
Collapse
|
15
|
Ferrari M, Quaresima V. A brief review on the history of human functional near-infrared spectroscopy (fNIRS) development and fields of application. Neuroimage 2012; 63:921-35. [PMID: 22510258 DOI: 10.1016/j.neuroimage.2012.03.049] [Citation(s) in RCA: 1089] [Impact Index Per Article: 90.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2011] [Revised: 02/21/2012] [Accepted: 03/16/2012] [Indexed: 12/14/2022] Open
Abstract
This review is aimed at celebrating the upcoming 20th anniversary of the birth of human functional near-infrared spectroscopy (fNIRS). After the discovery in 1992 that the functional activation of the human cerebral cortex (due to oxygenation and hemodynamic changes) can be explored by NIRS, human functional brain mapping research has gained a new dimension. fNIRS or optical topography, or near-infrared imaging or diffuse optical imaging is used mainly to detect simultaneous changes in optical properties of the human cortex from multiple measurement sites and displays the results in the form of a map or image over a specific area. In order to place current fNIRS research in its proper context, this paper presents a brief historical overview of the events that have shaped the present status of fNIRS. In particular, technological progresses of fNIRS are highlighted (i.e., from single-site to multi-site functional cortical measurements (images)), introduction of the commercial multi-channel systems, recent commercial wireless instrumentation and more advanced prototypes.
Collapse
Affiliation(s)
- Marco Ferrari
- Department of Health Sciences, University of L'Aquila, L'Aquila, Italy.
| | | |
Collapse
|
16
|
Ferrari M, Muthalib M, Quaresima V. The use of near-infrared spectroscopy in understanding skeletal muscle physiology: recent developments. PHILOSOPHICAL TRANSACTIONS. SERIES A, MATHEMATICAL, PHYSICAL, AND ENGINEERING SCIENCES 2011; 369:4577-90. [PMID: 22006907 DOI: 10.1098/rsta.2011.0230] [Citation(s) in RCA: 233] [Impact Index Per Article: 17.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/19/2023]
Abstract
This article provides a snapshot of muscle near-infrared spectroscopy (NIRS) at the end of 2010 summarizing the recent literature, offering the present status and perspectives of the NIRS instrumentation and methods, describing the main NIRS studies on skeletal muscle physiology, posing open questions and outlining future directions. So far, different NIRS techniques (e.g. continuous-wave (CW) and spatially, time- and frequency-resolved spectroscopy) have been used for measuring muscle oxygenation during exercise. In the last four years, approximately 160 muscle NIRS articles have been published on different physiological aspects (primarily muscle oxygenation and haemodynamics) of several upper- and lower-limb muscle groups investigated by using mainly two-channel CW and spatially resolved spectroscopy commercial instruments. Unfortunately, in only 15 of these studies were the advantages of using multi-channel instruments exploited. There are still several open questions in the application of NIRS in muscle studies: (i) whether NIRS can be used in subjects with a large fat layer; (ii) the contribution of myoglobin desaturation to the NIRS signal during exercise; (iii) the effect of scattering changes during exercise; and (iv) the effect of changes in skin perfusion, particularly during prolonged exercise. Recommendations for instrumentation advancements and future muscle NIRS studies are provided.
Collapse
Affiliation(s)
- Marco Ferrari
- Department of Health Sciences, University of L'Aquila, L'Aquila, Italy.
| | | | | |
Collapse
|
17
|
Crenshaw AG, Bronee L, Krag I, Jensen BR. Oxygenation and EMG in the proximal and distal vastus lateralis during submaximal isometric knee extension. J Sports Sci 2010; 28:1057-64. [PMID: 20686998 DOI: 10.1080/02640414.2010.489195] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
Abstract
Muscle oxygenation responses are reportedly greater in the distal muscle region than in the proximal muscle region. We combined near infrared spectroscopy and electromyography (EMG) to determine whether regional differences in oxygenation are associated with differences in (1) muscle activation and/or (2) fatigue development. Nine males performed 2-min sustained isometric knee extensions at 15% and 30% maximum voluntary contraction during which oxygenation and EMG were recorded simultaneously from proximal and distal locations of the vastus lateralis muscle. Near infrared spectroscopy variables for oxygen saturation (StO(2)%) were initial slope at contraction onset, peak drop, and recovery slope at contraction end. Electromyography produced the root mean square to indicate muscle activation and mean power frequency changes over time (decreasing slope) to indicate fatigue development. For StO(2)%, significantly greater peak drop and steeper recovery slope were found for the distal muscle region than for the proximal muscle region. Root mean square, however, was not different between locations. Mean power frequency decreased throughout the contractions but changes were not different between locations. Our results indicate that for modest submaximal contractions, regional differences in oxygenation are not associated with differences in muscle activation or with fatigue development (as interpreted by changes in mean power frequency over time).
Collapse
Affiliation(s)
- Albert G Crenshaw
- Centre for Musculoskeletal Research, University of Gävle, Gävle, Sweden.
| | | | | | | |
Collapse
|
18
|
Belau M, Ninck M, Hering G, Spinelli L, Contini D, Torricelli A, Gisler T. Noninvasive observation of skeletal muscle contraction using near-infrared time-resolved reflectance and diffusing-wave spectroscopy. JOURNAL OF BIOMEDICAL OPTICS 2010; 15:057007. [PMID: 21054123 DOI: 10.1117/1.3503398] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/19/2023]
Abstract
We introduce a method for noninvasively measuring muscle contraction in vivo, based on near-infrared diffusing-wave spectroscopy (DWS). The method exploits the information about time-dependent shear motions within the contracting muscle that are contained in the temporal autocorrelation function g(1)(τ,t) of the multiply scattered light field measured as a function of lag time, τ, and time after stimulus, t. The analysis of g(1)(τ,t) measured on the human M. biceps brachii during repetitive electrical stimulation, using optical properties measured with time-resolved reflectance spectroscopy, shows that the tissue dynamics giving rise to the speckle fluctuations can be described by a combination of diffusion and shearing. The evolution of the tissue Cauchy strain e(t) shows a strong correlation with the force, indicating that a significant part of the shear observed with DWS is due to muscle contraction. The evolution of the DWS decay time shows quantitative differences between the M. biceps brachii and the M. gastrocnemius, suggesting that DWS allows to discriminate contraction of fast- and slow-twitch muscle fibers.
Collapse
Affiliation(s)
- Markus Belau
- Universität Konstanz, Fachbereich Physik, 78457 Konstanz, Germany
| | | | | | | | | | | | | |
Collapse
|
19
|
Cen H, Lu R. Optimization of the hyperspectral imaging-based spatially-resolved system for measuring the optical properties of biological materials. OPTICS EXPRESS 2010; 18:17412-32. [PMID: 20721128 DOI: 10.1364/oe.18.017412] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/19/2023]
Abstract
This paper reports on the optimization and assessment of a hyperspectral imaging-based spatially-resolved system for determination of the optical properties of biological materials over the wavelengths of 500-1,000 nm. Twelve model samples covering a wide range of absorption and reduced scattering coefficients were created to validate the hyperspectral imaging system, and their true values of absorption and reduced scattering coefficients were determined and then cross-validated using three commonly used methods (i.e., transmittance, integrating sphere, and empirical equation). Light beam and source-detector distance were optimized through Monte Carlo simulations and experiments for the model samples. The optimal light beam should be of Gaussian type with the diameter of less than 1 mm, and the optimal minimum and maximum source-detector distance should be 1.5 mm and 10-20 mean free paths, respectively. The optimized hyperspectral imaging-based spatially-resolved system achieved good estimation of the optical parameters.
Collapse
Affiliation(s)
- Haiyan Cen
- Department of Biosystems and Agricultural Engineering, 105A Farrall Hall, Michigan State University, East Lansing, Michigan 48824, USA
| | | |
Collapse
|
20
|
Binzoni T, Van De Ville D. Full-field laser-Doppler imaging and its physiological significance for tissue blood perfusion. Phys Med Biol 2008; 53:6673-94. [PMID: 18997268 DOI: 10.1088/0031-9155/53/23/003] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Using Monte Carlo simulations for a semi-infinite medium representing a skeletal muscle tissue, it is demonstrated that the zero- and first-order moments of the power spectrum for a representative pixel of a full-field laser-Doppler imager behave differently from classical laser-Doppler flowmetry. In particular, the zero-order moment has a very low sensitivity to tissue blood volume changes, and it becomes completely insensitive if the probability for a photon to interact with a moving red blood cell is above 0.05. It is shown that the loss in sensitivity is due to the strong forward scatter of the propagating photons in biological tissues (i.e., anisotropy factor g = 0.9). The first-order moment is linearly related to the root mean square of the red blood cell velocity (the Brownian component), and there is also a positive relationship with tissue blood volume. The most common physiological interpretation of the first-order moment is as tissue blood volume times expectation of the blood velocity (in probabilistic terms). In this sense, the use of the first-order moment appears to be a reasonable approach for qualitative real-time blood flow monitoring, but it does not allow us to obtain information on blood velocity or volume independently. Finally, it is shown that the spatial and temporal resolution trade-off imposed by the CMOS detectors, used in full-field laser-Doppler hardware, may lead to measurements that vary oppositely with the underlying physiological quantities. Further improvements on detectors' sampling rate will overcome this limitation.
Collapse
Affiliation(s)
- T Binzoni
- Département des Neurosciences Fondamentales, University of Geneva, Switzerland.
| | | |
Collapse
|
21
|
Kek KJ, Kibe R, Niwayama M, Kudo N, Yamamoto K. Optical imaging instrument for muscle oxygenation based on spatially resolved spectroscopy. OPTICS EXPRESS 2008; 16:18173-87. [PMID: 18958095 DOI: 10.1364/oe.16.018173] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/02/2023]
Abstract
An imaging instrument based on spatially resolved spectroscopy that enables temporal and spatial analyses of muscle oxygenation was designed. The instrument is portable and can be connected to 32 compact and separate-type optical probes. Its measurement accuracy of O(2) saturation and hemoglobin concentration was evaluated using a tissue-equivalent phantom. Imaging and multi-point measurements of tissue oxygen saturation (S(t)O(2)) in the quadriceps muscle were also performed, and dynamic changes in S(t)O(2) in response to increase in exercise intensity (within the rectus femoris region) and variation in exercise protocol (among the rectus femoris, vastus lateralis and vastus medialis) were clearly shown.
Collapse
Affiliation(s)
- Khai Jun Kek
- Graduate School of Information Science and Technology, Hokkaido University, Sapporo, Japan.
| | | | | | | | | |
Collapse
|
22
|
Netz UJ, Beuthan J, Hielscher AH. Multipixel system for gigahertz frequency-domain optical imaging of finger joints. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2008; 79:034301. [PMID: 18377031 DOI: 10.1063/1.2840344] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/16/2023]
Abstract
Frequency-domain optical imaging systems have shown great promise for characterizing blood oxygenation, hemodynamics, and other physiological parameters in human and animal tissues. However, most of the frequency domain systems presented so far operate with source modulation frequencies below 150 MHz. At these low frequencies, their ability to provide accurate data for small tissue geometries such as encountered in imaging of finger joints or rodents is limited. Here, we present a new system that can provide data up to 1 GHz using an intensity modulated charged coupled device camera. After data processing, the images show the two-dimensional distribution of amplitude and phase of the light modulation on the finger surface. The system performance was investigated and test measurements on optical tissue phantoms were taken to investigate whether higher frequencies yield better signal-to-noise ratios (SNRs). It could be shown that local changes in optical tissue properties, as they appear in the initial stages of rheumatoid arthritis in a finger joint, are detectable by simple image evaluation, with the range of modulation frequency around 500 MHz proving to yield the highest SNR.
Collapse
Affiliation(s)
- Uwe J Netz
- Institut für Medizinische Physik und Lasermedizin, Charité-Universitätsmedizin Berlin, 14195 Berlin, Germany
| | | | | |
Collapse
|
23
|
Kim JG, Liu H. Variation of haemoglobin extinction coefficients can cause errors in the determination of haemoglobin concentration measured by near-infrared spectroscopy. Phys Med Biol 2007; 52:6295-322. [PMID: 17921586 DOI: 10.1088/0031-9155/52/20/014] [Citation(s) in RCA: 50] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Near-infrared spectroscopy or imaging has been extensively applied to various biomedical applications since it can detect the concentrations of oxyhaemoglobin (HbO(2)), deoxyhaemoglobin (Hb) and total haemoglobin (Hb(total)) from deep tissues. To quantify concentrations of these haemoglobin derivatives, the extinction coefficient values of HbO(2) and Hb have to be employed. However, it was not well recognized among researchers that small differences in extinction coefficients could cause significant errors in quantifying the concentrations of haemoglobin derivatives. In this study, we derived equations to estimate errors of haemoglobin derivatives caused by the variation of haemoglobin extinction coefficients. To prove our error analysis, we performed experiments using liquid-tissue phantoms containing 1% Intralipid in a phosphate-buffered saline solution. The gas intervention of pure oxygen was given in the solution to examine the oxygenation changes in the phantom, and 3 mL of human blood was added twice to show the changes in [Hb(total)]. The error calculation has shown that even a small variation (0.01 cm(-1) mM(-1)) in extinction coefficients can produce appreciable relative errors in quantification of Delta[HbO(2)], Delta[Hb] and Delta[Hb(total)]. We have also observed that the error of Delta[Hb(total)] is not always larger than those of Delta[HbO(2)] and Delta[Hb]. This study concludes that we need to be aware of any variation in haemoglobin extinction coefficients, which could result from changes in temperature, and to utilize corresponding animal's haemoglobin extinction coefficients for the animal experiments, in order to obtain more accurate values of Delta[HbO(2)], Delta[Hb] and Delta[Hb(total)] from in vivo tissue measurements.
Collapse
Affiliation(s)
- J G Kim
- Joint Graduate Program in Biomedical Engineering, University of Texas at Arlington, TX 76019, USA
| | | |
Collapse
|
24
|
Pifferi A, Torricelli A, Taroni P, Comelli D, Bassi A, Cubeddu R. Fully automated time domain spectrometer for the absorption and scattering characterization of diffusive media. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2007; 78:053103. [PMID: 17552808 DOI: 10.1063/1.2735567] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/07/2023]
Abstract
We describe a system for absorption and scattering spectroscopy of diffusive media based on time-resolved reflectance and transmittance measurements. The system is operated with mode-locked lasers tunable in the 550-1050 nm spectral range and on a detection chain based on time-correlated single-photon counting. All measurement procedures such as laser tuning and optimization, signal conditioning, data acquisition, and analysis are completely automated, permitting spectral measurements over the whole range in a few minutes. The criticalities of the system are discussed together with the strategies to compensate them. The Medphot protocol devised for the characterization of photon migration instruments was applied to assess the system performances in terms of accuracy, linearity, noise, stability, and reproducibility. Finally, an example of application of the instrument to the spectroscopy of powders is presented.
Collapse
Affiliation(s)
- Antonio Pifferi
- ULTRAS-CNR-INFM and IFN-CNR, Politecnico di Milano, Piazza Leonardo da Vinci 32, I-20133 Milan, Italy.
| | | | | | | | | | | |
Collapse
|
25
|
Laidevant A, da Silva A, Berger M, Dinten JM. Effects of the surface boundary on the determination of the optical properties of a turbid medium with time-resolved reflectance. APPLIED OPTICS 2006; 45:4756-64. [PMID: 16799691 DOI: 10.1364/ao.45.004756] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
Solutions of the time-dependent diffusion equation were developed to take into account the depth of the source and the detector inside a semi-infinite medium. These solutions permitted an evaluation of optical properties at different depths below the surface by fitting time-resolved data. Measurements were performed on liquid optical phantoms with optical fibers for delivering and collecting light. A time-correlated single-photon-counting chain was used for electronic detection. The determination of optical properties underlines the continuity between the surface model and the infinite model and shows the depth at which the derived solutions can be applied.
Collapse
Affiliation(s)
- Aurélie Laidevant
- Département Micro-Technologies pour la Biologie et la Santé, Recherche Technologique Grenoble, Grenoble Cedex, France.
| | | | | | | |
Collapse
|
26
|
Tualle JM, Nghiêm HL, Cheikh M, Ettori D, Tinet E, Avrillier S. Time-resolved diffusing wave spectroscopy beyond 300 transport mean free paths. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA. A, OPTICS, IMAGE SCIENCE, AND VISION 2006; 23:1452-7. [PMID: 16715164 DOI: 10.1364/josaa.23.001452] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/09/2023]
Abstract
We presented theoretical and experimental demonstrations of the possibilities of performing time-resolved diffusing wave spectroscopy: We successfully registered field fluctuations for selected photon path lengths that can surpass 300 transport mean free paths. Such performance opens new possibilities for biomedical optics applications.
Collapse
Affiliation(s)
- J-M Tualle
- Laboratoire de Physique des Lasers, Centre National de la Recherche Scientifique, Unité Mixte de Recherche 7538, Université Paris 13, Villetaneuse, France.
| | | | | | | | | | | |
Collapse
|
27
|
Keogh BF, Kopotic RJ. Recent findings in the use of reflectance oximetry: a critical review. Curr Opin Anaesthesiol 2006; 18:649-54. [PMID: 16534307 DOI: 10.1097/01.aco.0000191893.21444.56] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
PURPOSE OF REVIEW Pulse oximetry is ubiquitous but detailed understanding of the technology is poor. This is illustrated by publications addressing knowledge of pulse oximetry and those warning against the use of transmission pulse oximeter sensors in a reflectance manner, unintended by the manufacturers, owing to the potential for iatrogenic problems. Reflectance oximetry sensors are distinct and their application rather specific. Users must adhere to the manufacturer's guidelines to be assured of approximating the claimed accuracy and other specifications. Moreover, a thorough understanding of the device's shortcomings will optimize performance and avoid misuse. Cautious skepticism is appropriate with use of any technology but particularly with indirect measures of vital signs. RECENT FINDINGS The studies of reflectance sensors described here illustrate a diversity of successful applications and opportunities for further research. The genesis of applications for some sensors, for example fetal sensors, has proven helpful in other clinical settings where low mean arterial pressure and need for accurate monitoring of a SpO2 of less than 80% is poorly provided by transmittance sensors. Reflectance sensors are more prone to placement over contaminating sources (for example arteries and pigmentation), but their more sophisticated design can provide greater versatility than transillumination methods. SUMMARY This invited review highlights recent developments and applications of reflectance oximetry with an emphasis on the potential clinical and research advantages.
Collapse
Affiliation(s)
- Brian F Keogh
- Department of Anaesthesia & Intensive Care, Royal Brompton Hospital, London, UK.
| | | |
Collapse
|
28
|
Abstract
This article reviews recent developments in selected imaging technologies focused on the cardiovascular system. The techniques covered are: ultrasound biomicroscopy (UBM), microSPECT, microPET, near infrared imaging, and quantum dots. For each technique, the basic physical principles are explained and recent example applications demonstrated.
Collapse
Affiliation(s)
- Elliot R McVeigh
- Laboratory of Cardiac Energetics, NHLBI, National Institutes of Health, Bethesda, MD, USA.
| |
Collapse
|
29
|
Mizuno M, Tokizawa K, Muraoka I. Heterogeneous oxygenation in nonexercising triceps surae muscle during contralateral isometric exercise. Eur J Appl Physiol 2006; 97:181-8. [PMID: 16565864 DOI: 10.1007/s00421-005-0110-8] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/17/2005] [Indexed: 10/24/2022]
Abstract
To test whether changes in oxygenation of a resting skeletal muscle, evoked by a static contraction in a contralateral muscle, is uniform within a given skeletal muscle, we used near-infrared spectroscopy (NIRS). Seven subjects performed 2 min static knee extension exercise at 30% of maximal voluntary contraction. Changes in oxygenated hemoglobin (HbO(2)) were monitored using multiple-channel NIRS (40 channels, 13 sources and 12 detectors) attached on the contralateral nonexercising triceps surae muscle. Changes in HbO(2) were expressed as a percentage of total labile signals. To characterize the distribution of changes in HbO(2), channels were compared between their positions on the triceps surae muscle, and represented as 'proximal versus distal' and 'lateral versus medial' portions. During static muscle contraction, the averaged changes in HbO(2) of all channels were correlated with those in calf blood flow (plethysmography; R (2)=0.188, P<0.05) and with calf vascular conductance (R (2)=0.146, P<0.05). HbO(2) did not differ significantly between the lateral and medial portions of the triceps surae muscle. In contrast, the decrease of HbO(2) in the proximal portion of the muscle was greater than that of the distal portion (P<0.05). These results indicate that the changes in oxygenation of a resting muscle, evoked by static contraction of the contralateral muscle, are heterogeneous.
Collapse
Affiliation(s)
- Masaki Mizuno
- Faculty of Sport Sciences, Waseda University, 2-579-15 Mikajima, 359-1192, Tokorozawa, Saitama, Japan
| | | | | |
Collapse
|
30
|
Binzoni T, Leung TS, Rüfenacht D, Delpy DT. Absorption and scattering coefficient dependence of laser-Doppler flowmetry models for large tissue volumes. Phys Med Biol 2006; 51:311-33. [PMID: 16394341 DOI: 10.1088/0031-9155/51/2/009] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
Abstract
Based on quasi-elastic scattering theory (and random walk on a lattice approach), a model of laser-Doppler flowmetry (LDF) has been derived which can be applied to measurements in large tissue volumes (e.g. when the interoptode distance is >30 mm). The model holds for a semi-infinite medium and takes into account the transport-corrected scattering coefficient and the absorption coefficient of the tissue, and the scattering coefficient of the red blood cells. The model holds for anisotropic scattering and for multiple scattering of the photons by the moving scatterers of finite size. In particular, it has also been possible to take into account the simultaneous presence of both Brownian and pure translational movements. An analytical and simplified version of the model has also been derived and its validity investigated, for the case of measurements in human skeletal muscle tissue. It is shown that at large optode spacing it is possible to use the simplified model, taking into account only a 'mean' light pathlength, to predict the blood flow related parameters. It is also demonstrated that the 'classical' blood volume parameter, derived from LDF instruments, may not represent the actual blood volume variations when the investigated tissue volume is large. The simplified model does not need knowledge of the tissue optical parameters and thus should allow the development of very simple and cost-effective LDF hardware.
Collapse
Affiliation(s)
- T Binzoni
- Département de Neurosciences Fondamentales, Faculty of Medicine, University of Geneva, Switzerland.
| | | | | | | |
Collapse
|
31
|
Alexandrakis G, Rannou FR, Chatziioannou AF. Tomographic bioluminescence imaging by use of a combined optical-PET (OPET) system: a computer simulation feasibility study. Phys Med Biol 2005; 50:4225-41. [PMID: 16177541 PMCID: PMC1317109 DOI: 10.1088/0031-9155/50/17/021] [Citation(s) in RCA: 291] [Impact Index Per Article: 15.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
The feasibility and limits in performing tomographic bioluminescence imaging with a combined optical-PET (OPET) system were explored by simulating its image formation process. A micro-MRI based virtual mouse phantom was assigned appropriate tissue optical properties to each of its segmented internal organs at wavelengths spanning the emission spectrum of the firefly luciferase at 37 degrees C. The TOAST finite-element code was employed to simulate the diffuse transport of photons emitted from bioluminescence sources in the mouse. OPET measurements were simulated for single-point, two-point and distributed bioluminescence sources located in different organs such as the liver, the kidneys and the gut. An expectation maximization code was employed to recover the intensity and location of these simulated sources. It was found that spectrally resolved measurements were necessary in order to perform tomographic bioluminescence imaging. The true location of emission sources could be recovered if the mouse background optical properties were known a priori. The assumption of a homogeneous optical property background proved inadequate for describing photon transport in optically heterogeneous tissues and led to inaccurate source localization in the reconstructed images. The simulation results pointed out specific methodological challenges that need to be addressed before a practical implementation of OPET-based bioluminescence tomography is achieved.
Collapse
Affiliation(s)
- George Alexandrakis
- David Geffen School of Medicine at UCLA, Crump Institute for Molecular Imaging, University of California, 700 Westwood Plaza, Los Angeles, CA 90095, USA
| | - Fernando R Rannou
- Departamento de Ingenieria Informatica, Universidad de Santiago de Chile (USACH), Av. Ecuador 3659, Santiago, Chile
| | - Arion F Chatziioannou
- David Geffen School of Medicine at UCLA, Crump Institute for Molecular Imaging, University of California, 700 Westwood Plaza, Los Angeles, CA 90095, USA
- E-mail:
| |
Collapse
|
32
|
Pifferi A, Torricelli A, Bassi A, Taroni P, Cubeddu R, Wabnitz H, Grosenick D, Möller M, Macdonald R, Swartling J, Svensson T, Andersson-Engels S, van Veen RLP, Sterenborg HJCM, Tualle JM, Nghiem HL, Avrillier S, Whelan M, Stamm H. Performance assessment of photon migration instruments: the MEDPHOT protocol. APPLIED OPTICS 2005; 44:2104-14. [PMID: 15838951 DOI: 10.1364/ao.44.002104] [Citation(s) in RCA: 99] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
We propose a comprehensive protocol for the performance assessment of photon migration instruments. The protocol has been developed within the European Thematic Network MEDPHOT (optical methods for medical diagnosis and monitoring of diseases) and is based on five criteria: accuracy, linearity, noise, stability, and reproducibility. This protocol was applied to a total of 8 instruments with a set of 32 phantoms, covering a wide range of optical properties.
Collapse
Affiliation(s)
- Antonio Pifferi
- Laboratorio Nazionale per l'Ottica Ultra-rapida e Ultra-intensa, Dipartimento di Fisica e Istituto di Fotonicae Nanotecnologie, Consiglio Nazionale delle Ricerche, Politecnico di Milano, I-20133 Milan, Italy.
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
33
|
Tualle JM, Nghiêm HL, Schäfauer C, Berthaud P, Tinet E, Ettori D, Avrillier S. Time-resolved measurements from speckle interferometry. OPTICS LETTERS 2005; 30:50-52. [PMID: 15648634 DOI: 10.1364/ol.30.000050] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
We present time-resolved measurements by speckle interferometry of the light scattered by a liquid medium. Measurements were performed by use of reflectance geometry and are compared with results obtained in the same conditions with a femtosecond laser and a streak camera. The setup was also tested in vivo on the forearm of a human volunteer to demonstrate the potential utility of such a setup for biomedical applications.
Collapse
Affiliation(s)
- J M Tualle
- Laboratoire de Physique des Lasers (Centre National de la Recherche Scientifique, Unité Mixte de Recherche 7538), Université Paris 13, 99 Avenue J.-B. Clément, 93430 Villetaneuse, France.
| | | | | | | | | | | | | |
Collapse
|
34
|
Quaresima V, Ferrari M, Torricelli A, Spinelli L, Pifferi A, Cubeddu R. Bilateral prefrontal cortex oxygenation responses to a verbal fluency task: a multichannel time-resolved near-infrared topography study. JOURNAL OF BIOMEDICAL OPTICS 2005; 10:11012. [PMID: 15847578 DOI: 10.1117/1.1851512] [Citation(s) in RCA: 39] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/19/2023]
Abstract
The letter-fluency task-induced response over the prefrontal cortex is investigated bilaterally on eight subjects using a recently developed compact, eight-channel, time-resolved, near-IR system. The cross-subject mean values of prefrontal cortex oxygen saturation (SO2) were 68.8+/-3.2% (right) and 71.0+/-3.6% (left), and of total hemoglobin concentration (tHb) were 69.6+/-9.6 microM (right) and 69.5+/-9.9 microM (left). The typical cortical activation response to the cognitive task [characterized by an increase in oxyhemoglobin (O2Hb) with a concurrent decrease in deoxyhemoglobin (HHb)] at each measurement point is observed in only four subjects. In this subset, the amplitude of the O2Hb increase and HHb decrease is uniform over each prefrontal cortex area and comparable between the two hemispheres. These findings agree with previous studies using continuous wave functional near-IR spectroscopy and functional magnetic resonance imaging, therefore demonstrating the potential of a time-resolved spectroscopy approach. In addition, a significant increase in SO2 levels was observed in the right (1.1+/-0.5%) compared to left side of the prefrontal cortex (0.9+/-0.5%) (P=0.005). A different pattern of cortical activation (characterized by the lack of HHb decrease or even increased HHb) was observed in the remaining subjects.
Collapse
Affiliation(s)
- Valentina Quaresima
- University of L'Aquila, Department of Biomedical Sciences and Technologies, I-67100 L'Aquila, Italy.
| | | | | | | | | | | |
Collapse
|