1
|
Cremin K, Meloni GN, Valavanis D, Soyer OS, Unwin PR. Can Single Cell Respiration be Measured by Scanning Electrochemical Microscopy (SECM)? ACS MEASUREMENT SCIENCE AU 2023; 3:361-370. [PMID: 37868362 PMCID: PMC10588932 DOI: 10.1021/acsmeasuresciau.3c00019] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 04/27/2023] [Revised: 06/13/2023] [Accepted: 06/13/2023] [Indexed: 10/24/2023]
Abstract
Ultramicroelectrode (UME), or, equivalently, microelectrode, probes are increasingly used for single-cell measurements of cellular properties and processes, including physiological activity, such as metabolic fluxes and respiration rates. Major challenges for the sensitivity of such measurements include: (i) the relative magnitude of cellular and UME fluxes (manifested in the current); and (ii) issues around the stability of the UME response over time. To explore the extent to which these factors impact the precision of electrochemical cellular measurements, we undertake a systematic analysis of measurement conditions and experimental parameters for determining single cell respiration rates via the oxygen consumption rate (OCR) in single HeLa cells. Using scanning electrochemical microscopy (SECM), with a platinum UME as the probe, we employ a self-referencing measurement protocol, rarely employed in SECM, whereby the UME is repeatedly approached from bulk solution to a cell, and a short pulse to oxygen reduction reaction (ORR) potential is performed near the cell and in bulk solution. This approach enables the periodic tracking of the bulk UME response to which the near-cell response is repeatedly compared (referenced) and also ensures that the ORR near the cell is performed only briefly, minimizing the effect of the electrochemical process on the cell. SECM experiments are combined with a finite element method (FEM) modeling framework to simulate oxygen diffusion and the UME response. Taking a realistic range of single cell OCR to be 1 × 10-18 to 1 × 10-16 mol s-1, results from the combination of FEM simulations and self-referencing SECM measurements show that these OCR values are at, or below, the present detection sensitivity of the technique. We provide a set of model-based suggestions for improving these measurements in the future but highlight that extraordinary improvements in the stability and precision of SECM measurements will be required if single cell OCR measurements are to be realized.
Collapse
Affiliation(s)
- Kelsey Cremin
- Bio-Electrical
Engineering Innovation Hub, Department of Chemistry, Molecular Analytical
Science Centre for Doctoral Training (MAS CDT), School of Life Sciences, the University of Warwick, Coventry CV4 7AL, United Kingdom
| | - Gabriel N. Meloni
- Bio-Electrical
Engineering Innovation Hub, Department of Chemistry, Molecular Analytical
Science Centre for Doctoral Training (MAS CDT), School of Life Sciences, the University of Warwick, Coventry CV4 7AL, United Kingdom
| | - Dimitrios Valavanis
- Bio-Electrical
Engineering Innovation Hub, Department of Chemistry, Molecular Analytical
Science Centre for Doctoral Training (MAS CDT), School of Life Sciences, the University of Warwick, Coventry CV4 7AL, United Kingdom
| | - Orkun S. Soyer
- Bio-Electrical
Engineering Innovation Hub, Department of Chemistry, Molecular Analytical
Science Centre for Doctoral Training (MAS CDT), School of Life Sciences, the University of Warwick, Coventry CV4 7AL, United Kingdom
| | - Patrick R. Unwin
- Bio-Electrical
Engineering Innovation Hub, Department of Chemistry, Molecular Analytical
Science Centre for Doctoral Training (MAS CDT), School of Life Sciences, the University of Warwick, Coventry CV4 7AL, United Kingdom
| |
Collapse
|
2
|
Gulati K, Adachi T. Profiling to Probing: Atomic force microscopy to characterize nano-engineered implants. Acta Biomater 2023; 170:15-38. [PMID: 37562516 DOI: 10.1016/j.actbio.2023.08.006] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2023] [Revised: 07/26/2023] [Accepted: 08/03/2023] [Indexed: 08/12/2023]
Abstract
Surface modification of implants in the nanoscale or implant nano-engineering has been recognized as a strategy for augmenting implant bioactivity and achieving long-term implant success. Characterizing and optimizing implant characteristics is crucial to achieving desirable effects post-implantation. Modified implant enables tailored, guided and accelerated tissue integration; however, our understanding is limited to multicellular (bulk) interactions. Finding the nanoscale forces experienced by a single cell on nano-engineered implants will aid in predicting implants' bioactivity and engineering the next generation of bioactive implants. Atomic force microscope (AFM) is a unique tool that enables surface characterization and understanding of the interactions between implant surface and biological tissues. The characterization of surface topography using AFM to gauge nano-engineered implants' characteristics (topographical, mechanical, chemical, electrical and magnetic) and bioactivity (adhesion of cells) is presented. A special focus of the review is to discuss the use of single-cell force spectroscopy (SCFS) employing AFM to investigate the minute forces involved with the adhesion of a single cell (resident tissue cell or bacterium) to the surface of nano-engineered implants. Finally, the research gaps and future perspectives relating to AFM-characterized current and emerging nano-engineered implants are discussed towards achieving desirable bioactivity performances. This review highlights the use of advanced AFM-based characterization of nano-engineered implant surfaces via profiling (investigating implant topography) or probing (using a single cell as a probe to study precise adhesive forces with the implant surface). STATEMENT OF SIGNIFICANCE: Nano-engineering is emerging as a surface modification platform for implants to augment their bioactivity and achieve favourable treatment outcomes. In this extensive review, we closely examine the use of Atomic Force Microscopy (AFM) to characterize the properties of nano-engineered implant surfaces (topography, mechanical, chemical, electrical and magnetic). Next, we discuss Single-Cell Force Spectroscopy (SCFS) via AFM towards precise force quantification encompassing a single cell's interaction with the implant surface. This interdisciplinary review will appeal to researchers from the broader scientific community interested in implants and cell adhesion to implants and provide an improved understanding of the surface characterization of nano-engineered implants.
Collapse
Affiliation(s)
- Karan Gulati
- Institute for Life and Medical Sciences, Kyoto University, Sakyo, Kyoto 606-8507, Japan; The University of Queensland, School of Dentistry, Herston QLD 4006, Australia.
| | - Taiji Adachi
- Institute for Life and Medical Sciences, Kyoto University, Sakyo, Kyoto 606-8507, Japan
| |
Collapse
|
3
|
Cremin K, Duxbury SJN, Rosko J, Soyer OS. Formation and emergent dynamics of spatially organized microbial systems. Interface Focus 2023; 13:20220062. [PMID: 36789239 PMCID: PMC9912014 DOI: 10.1098/rsfs.2022.0062] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2022] [Accepted: 12/19/2022] [Indexed: 02/12/2023] Open
Abstract
Spatial organization is the norm rather than the exception in the microbial world. While the study of microbial physiology has been dominated by studies in well-mixed cultures, there is now increasing interest in understanding the role of spatial organization in microbial physiology, coexistence and evolution. Where studied, spatial organization has been shown to influence all three of these aspects. In this mini review and perspective article, we emphasize that the dynamics within spatially organized microbial systems (SOMS) are governed by feedbacks between local physico-chemical conditions, cell physiology and movement, and evolution. These feedbacks can give rise to emergent dynamics, which need to be studied through a combination of spatio-temporal measurements and mathematical models. We highlight the initial formation of SOMS and their emergent dynamics as two open areas of investigation for future studies. These studies will benefit from the development of model systems that can mimic natural ones in terms of species composition and spatial structure.
Collapse
Affiliation(s)
- Kelsey Cremin
- School of Life Sciences, University of Warwick, Coventry CV4 7AL, UK
| | | | - Jerko Rosko
- School of Life Sciences, University of Warwick, Coventry CV4 7AL, UK
| | - Orkun S. Soyer
- School of Life Sciences, University of Warwick, Coventry CV4 7AL, UK
| |
Collapse
|
4
|
Awadein M, Sparey M, Grall S, Kienberger F, Clement N, Gramse G. Nanoscale electrochemical charge transfer kinetics investigated by electrochemical scanning microwave microscopy. NANOSCALE ADVANCES 2023; 5:659-667. [PMID: 36756524 PMCID: PMC9890956 DOI: 10.1039/d2na00671e] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/30/2022] [Accepted: 11/17/2022] [Indexed: 06/18/2023]
Abstract
We show how microwave microscopy can be used to probe local charge transfer reactions with unprecedented sensitivity, visualizing surface reactions with only a few hundred molecules involved. While microwaves are too fast under classical conditions to interact and sense electrochemical processes, this is different at the nanoscale, where our heterodyne microwave sensing method allows for highly sensitive local cyclic voltammetry (LCV) and local electrochemical impedance spectroscopy (LEIS). LCV and LEIS allow for precise measurement of the localized charge transfer kinetics, as illustrated in this study for a ferrocene self-assembled monolayer immersed in an electrolyte. The theoretical analysis presented here enables a consistent mapping of the faradaic kinetics and the parasitic contributions (nonfaradaic) to be spectrally resolved and subtracted. In particular, this methodology reveals an undistorted assessment of accessible redox site density of states associated with faradaic capacitance, fractional surface coverage and electron transfer kinetics at the nanoscale. The developed methodology opens a new perspective on comprehending electrochemical reactivity at the nanoscale.
Collapse
Affiliation(s)
- Mohamed Awadein
- Keysight Labs Austria, Keysight Technologies Linz 4020 Austria
| | - Maxwell Sparey
- Keysight Labs Austria, Keysight Technologies Linz 4020 Austria
| | - Simon Grall
- LIMMS/CNRS Institute of Industrial Science, University of Tokyo Tokyo 153-8505 Japan
| | | | - Nicolas Clement
- LIMMS/CNRS Institute of Industrial Science, University of Tokyo Tokyo 153-8505 Japan
| | - Georg Gramse
- Keysight Labs Austria, Keysight Technologies Linz 4020 Austria
- Institute of Biophysics, Johannes Kepler University Linz 4020 Austria
| |
Collapse
|
5
|
Scanning electrochemical microscope as a tool for the electroporation of living yeast cells. Biosens Bioelectron 2022; 205:114096. [PMID: 35219018 DOI: 10.1016/j.bios.2022.114096] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2021] [Revised: 02/08/2022] [Accepted: 02/11/2022] [Indexed: 12/31/2022]
Abstract
In this study, a scanning electrochemical microscope (SECM) was for the first time adapted to perform the electroporation process of living yeast cells. We have demonstrated that relatively low voltage pulses of 1-2 V vs. Ag/AglCl,Cl-sat applied to gold-based ultramicroelectrode (Au-UME) are performing reversible electroporation of yeast cells immobilized on fluorine-doped tin oxide (FTO)/glass surface. SECM and electrochemical impedance spectroscopy (EIS) were used for the determination of quantitative electrochemical characteristics before and after the electroporation. The electrochemical impedance spectroscopy (EIS) illustrated significant electrochemical changes of electroporated yeast cells, while SECM feedback mode surface vertical scan current-distance curves showed that the diameter of the area affected by the electrical pulse is about 25 times larger than the diameter of the Au-UME used for the electroporation process. The results presented in this research open up a possibility to develop a targeted electroporation system which will affect only the selected area of tissue or some other cell-covered surface. Such model is promising for the selective treatment of selected cells in tissues and/or other sensitive biological systems while selecting the location and size of electroporated areas.
Collapse
|
6
|
Al Shamsi M, Shahin A, Kamyan D, Alnaqbi A, Shaban S, Souid AK. Conserved spinal cord bioenergetics in experimental autoimmune encephalomyelitis in C57BL6 mice, measured using phosphorescence oxygen analyzer. Heliyon 2021; 7:e08111. [PMID: 34693048 PMCID: PMC8511844 DOI: 10.1016/j.heliyon.2021.e08111] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2020] [Revised: 12/23/2020] [Accepted: 09/28/2021] [Indexed: 11/30/2022] Open
Abstract
Background We have previously reported that spinal cord respiration (cellular mitochondrial oxygen consumption) and ATP content are conserved in the studied model of experimental autoimmune encephalomyelitis (EAE), foreseeing a recovery of the diseased rats. This exemplary lesion of multiple sclerosis is used here to measure spinal cord bioenergetics in C57BL6 mice. Our hypothesis is that, despite the well-known focal axonal mitochondrial pathology, bioenergetics of the CNS is reasonably preserved in this disease. Methods EAE was induced with an immunodominant myelin oligodendrocyte glycoprotein epitope in complete Freund's adjuvant, appended by injections of pertussis toxin. A low- and high-dose of the encephalitogen, administered into base of tail or hind-flank, were investigated. Control mice received only the incomplete adjuvant into tail. Oxygen measurements were based on quenching the phosphorescence of Pd(II) meso-tetra (sulfophenyl) tetrabenzoporphyrin by molecular oxygen. Cellular ATP was measured using the luciferin/luciferase system. Results The kinetics of spinal cord oxygen consumption was zero-order (linear with time) and inhibited by cyanide, confirming oxygen was reduced by cytochrome oxidase. The rate of respiration (in μM O2.min−1.mg−1; measured on Days 13–28) in control mice was (mean ± SD) 0.086 ± 0.024 (n = 8) and in immunized mice was 0.079 ± 0.020 (n = 15, P = 0.265, Mann-Whitney test). Consistently, cellular ATP (in μmol mg−1 dry pellet weight; measured on Days 13–28) in control mice was 0.068 ± 0.079 (n = 11) and in immunized mice was 0.063 ± 0.061 (n = 24, P = 0.887, Mann-Whitney U test). Conclusions In vitro measurements of spinal cord bioenergetics show conservation of the mitochondrial function in mice with EAE. These results suggest the previously documented reduced mitochondrial electrochemical potential in this disease is alterable, and likely reflects the adverse events of neuroinflammation.
Collapse
Affiliation(s)
- Mariam Al Shamsi
- Department of Microbiology and Immunology, UAE University, College of Medicine and Health Sciences, Al Ain, P.O. Box 17666, Abu Dhabi, United Arab Emirates
| | - Allen Shahin
- Department of Microbiology and Immunology, UAE University, College of Medicine and Health Sciences, Al Ain, P.O. Box 17666, Abu Dhabi, United Arab Emirates
| | - Doua Kamyan
- Department of Microbiology and Immunology, UAE University, College of Medicine and Health Sciences, Al Ain, P.O. Box 17666, Abu Dhabi, United Arab Emirates
| | - Alanood Alnaqbi
- Department of Microbiology and Immunology, UAE University, College of Medicine and Health Sciences, Al Ain, P.O. Box 17666, Abu Dhabi, United Arab Emirates
| | - Sami Shaban
- Department of Medical Education, UAE University, College of Medicine and Health Sciences, Al Ain, P.O. Box 17666, Abu Dhabi, United Arab Emirates
| | - Abdul-Kader Souid
- Department of Pediatrics, UAE University, College of Medicine and Health Sciences, Al Ain, P.O. Box 17666, Abu Dhabi, United Arab Emirates
| |
Collapse
|
7
|
Golubchik A, Lopes LC, Singh V, Kuss S. Pharma‐molecule Transport across Bacterial Membranes: Detection and Quantification Approaches by Electrochemistry and Bioanalytical Methods. Angew Chem Int Ed Engl 2021. [DOI: 10.1002/ange.202101055] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Affiliation(s)
- Alon Golubchik
- Department Chemistry University of Manitoba Winnipeg R3T 2N2 Canada
| | | | - Vikram Singh
- Department Chemistry University of Manitoba Winnipeg R3T 2N2 Canada
| | - Sabine Kuss
- Department Chemistry University of Manitoba Winnipeg R3T 2N2 Canada
| |
Collapse
|
8
|
Golubchik A, Lopes LC, Singh V, Kuss S. Pharma-molecule Transport across Bacterial Membranes: Detection and Quantification Approaches by Electrochemistry and Bioanalytical Methods. Angew Chem Int Ed Engl 2021; 60:22112-22124. [PMID: 33979000 DOI: 10.1002/anie.202101055] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2021] [Indexed: 11/07/2022]
Abstract
Antibiotic resistance is a significant challenge encountered by healthcare systems on a global scale. Knowledge about membrane transport of antibiotics and other pharmacologically relevant molecules in bacteria is crucial towards understanding and overcoming antibiotic resistance, as drug resistance often depends on drug transport. This comprehensive literature review discusses the detection and quantification of membrane transport of pharma-molecules in bacteria and highlights the importance of molecule transport to antibiotic resistance. This review emphasizes electrochemical and electrophysiological methods of detection and quantification. The results of this literature review reveal a substantial diversity in methods and types of quantitative information collected.
Collapse
Affiliation(s)
- Alon Golubchik
- Department Chemistry, University of Manitoba, Winnipeg, R3T 2N2, Canada
| | | | - Vikram Singh
- Department Chemistry, University of Manitoba, Winnipeg, R3T 2N2, Canada
| | - Sabine Kuss
- Department Chemistry, University of Manitoba, Winnipeg, R3T 2N2, Canada
| |
Collapse
|
9
|
Santos CS, Macedo F, Kowaltowski AJ, Bertotti M, Unwin PR, Marques da Cunha F, Meloni GN. Unveiling the contribution of the reproductive system of individual Caenorhabditis elegans on oxygen consumption by single-point scanning electrochemical microscopy measurements. Anal Chim Acta 2021; 1146:88-97. [PMID: 33461723 PMCID: PMC7836392 DOI: 10.1016/j.aca.2020.12.030] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2020] [Revised: 12/11/2020] [Accepted: 12/17/2020] [Indexed: 01/03/2023]
Abstract
Metabolic analysis in animals is usually either evaluated as whole-body measurements or in isolated tissue samples. To reveal tissue specificities in vivo, this study uses scanning electrochemical microscopy (SECM) to provide localized oxygen consumption rates (OCRs) in different regions of single adult Caenorhabditis elegans individuals. This is achieved by measuring the oxygen reduction current at the SECM tip electrode and using a finite element method model of the experiment that defines oxygen concentration and flux at the surface of the organism. SECM mapping measurements uncover a marked heterogeneity of OCR along the worm, with high respiration rates at the reproductive system region. To enable sensitive and quantitative measurements, a self-referencing approach is adopted, whereby the oxygen reduction current at the SECM tip is measured at a selected point on the worm and in bulk solution (calibration). Using genetic and pharmacological approaches, our SECM measurements indicate that viable eggs in the reproductive system are the main contributors in the total oxygen consumption of adult Caenorhabditis elegans. The finding that large regional differences in OCR exist within the animal provides a new understanding of oxygen consumption and metabolic measurements, paving the way for tissue-specific metabolic analyses and toxicity evaluation within single organisms.
Collapse
Affiliation(s)
- Carla S Santos
- Departamento de Química Fundamental, Av. Professor Lineu Prestes, 748, 05508-000, São Paulo, SP, Brazil.
| | - Felipe Macedo
- Departamento de Bioquímica, Escola Paulista de Medicina, Universidade Federal de São Paulo, Rua três de Maio, 100, 04044-020, São Paulo, Brazil
| | - Alicia J Kowaltowski
- Departamento de Bioquímica, Instituto de Química, Universidade de São Paulo, Av. Professor Lineu Prestes, 748, 05508-000, São Paulo, SP, Brazil
| | - Mauro Bertotti
- Departamento de Química Fundamental, Av. Professor Lineu Prestes, 748, 05508-000, São Paulo, SP, Brazil
| | - Patrick R Unwin
- Department of Chemistry, University of Warwick, Coventry, CV4 7AL, United Kingdom; Bio-Electrical Engineering Innovation Hub, University of Warwick, Coventry, CV4 7AL, United Kingdom
| | - Fernanda Marques da Cunha
- Departamento de Bioquímica, Escola Paulista de Medicina, Universidade Federal de São Paulo, Rua três de Maio, 100, 04044-020, São Paulo, Brazil
| | - Gabriel N Meloni
- Department of Chemistry, University of Warwick, Coventry, CV4 7AL, United Kingdom; Bio-Electrical Engineering Innovation Hub, University of Warwick, Coventry, CV4 7AL, United Kingdom.
| |
Collapse
|
10
|
Mark A, Helfricht N, Rauh A, Xue J, Knödler P, Schumacher T, Karg M, Du B, Lippitz M, Papastavrou G. Electrokinetics in Micro-channeled Cantilevers: Extending the Toolbox for Reversible Colloidal Probes and AFM-Based Nanofluidics. Sci Rep 2019; 9:20294. [PMID: 31889103 PMCID: PMC6937245 DOI: 10.1038/s41598-019-56716-0] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2019] [Accepted: 12/04/2019] [Indexed: 11/23/2022] Open
Abstract
The combination of atomic force microscopy (AFM) with nanofluidics, also referred to as FluidFM, has facilitated new applications in scanning ion conductance microscopy, direct force measurements, lithography, or controlled nanoparticle deposition. An essential element of this new type of AFMs is its cantilever, which bears an internal micro-channel with a defined aperture at the end. Here, we present a new approach for in-situ characterization of the internal micro-channels, which is non-destructive and based on electrochemical methods. It allows for probing the internal environment of a micro-channeled cantilever and the corresponding aperture, respectively. Acquiring the streaming current in the micro-channel allows to determine not only the state of the aperture over a wide range of ionic strengths but also the surface chemistry of the cantilever’s internal channel. The high practical applicability of this method is demonstrated by detecting the aspiration of polymeric, inorganic and hydrogel particles with diameters ranging from several µm down to 300 nm. By verifying in-situ the state of the aperture, i.e. open versus closed, electrophysiological or nano-deposition experiments will be significantly facilitated. Moreover, our approach is of high significance for direct force measurements by the FluidFM-technique and sub-micron colloidal probes.
Collapse
Affiliation(s)
- Andreas Mark
- Physical Chemistry II, University of Bayreuth, Universitätsstr. 30, 95440, Bayreuth, Germany
| | - Nicolas Helfricht
- Physical Chemistry II, University of Bayreuth, Universitätsstr. 30, 95440, Bayreuth, Germany.,Bavarian Polymer Institute, University of Bayreuth, Universitätsstr. 30, 95440, Bayreuth, Germany
| | - Astrid Rauh
- Physical Chemistry I, Heinrich-Heine-University Düsseldorf, Universitätsstr. 1, 40204, Düsseldorf, Germany
| | - Jinqiao Xue
- MOE Key Laboratory of Macromolecular Synthesis and Functionalization, Department of Polymer Science and Engineering, Zhejiang University, Hangzhou, 310027, China
| | - Patrick Knödler
- Experimental Physics III, University of Bayreuth, Universitätsstr. 30, 95440, Bayreuth, Germany
| | - Thorsten Schumacher
- Experimental Physics III, University of Bayreuth, Universitätsstr. 30, 95440, Bayreuth, Germany
| | - Matthias Karg
- Physical Chemistry I, Heinrich-Heine-University Düsseldorf, Universitätsstr. 1, 40204, Düsseldorf, Germany
| | - Binyang Du
- MOE Key Laboratory of Macromolecular Synthesis and Functionalization, Department of Polymer Science and Engineering, Zhejiang University, Hangzhou, 310027, China
| | - Markus Lippitz
- Experimental Physics III, University of Bayreuth, Universitätsstr. 30, 95440, Bayreuth, Germany
| | - Georg Papastavrou
- Physical Chemistry II, University of Bayreuth, Universitätsstr. 30, 95440, Bayreuth, Germany. .,Bavarian Polymer Institute, University of Bayreuth, Universitätsstr. 30, 95440, Bayreuth, Germany.
| |
Collapse
|
11
|
Cheong LZ, Zhao W, Song S, Shen C. Lab on a tip: Applications of functional atomic force microscopy for the study of electrical properties in biology. Acta Biomater 2019; 99:33-52. [PMID: 31425893 DOI: 10.1016/j.actbio.2019.08.023] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2019] [Revised: 07/17/2019] [Accepted: 08/13/2019] [Indexed: 12/11/2022]
Abstract
Electrical properties, such as charge propagation, dielectrics, surface potentials, conductivity, and piezoelectricity, play crucial roles in biomolecules, biomembranes, cells, tissues, and other biological samples. However, characterizing these electrical properties in delicate biosamples is challenging. Atomic Force Microscopy (AFM), the so called "Lab on a Tip" is a powerful and multifunctional approach to quantitatively study the electrical properties of biological samples at the nanometer level. Herein, the principles, theories, and achievements of various modes of AFM in this area have been reviewed and summarized. STATEMENT OF SIGNIFICANCE: Electrical properties such as dielectric and piezoelectric forces, charge propagation behaviors play important structural and functional roles in biosystems from the single molecule level, to cells and tissues. Atomic force microscopy (AFM) has emerged as an ideal toolkit to study electrical property of biology. Herein, the basic principles of AFM are described. We then discuss the multiple modes of AFM to study the electrical properties of biological samples, including Electrostatic Force Microscopy (EFM), Kelvin Probe Force Microscopy (KPFM), Conductive Atomic Force Microscopy (CAFM), Piezoresponse Force Microscopy (PFM) and Scanning ElectroChemical Microscopy (SECM). Finally, the outlook, prospects, and challenges of the various AFM modes when studying the electrical behaviour of the samples are discussed.
Collapse
|
12
|
Claudio-Cintrón MA, Rodríguez-López J. Scanning electrochemical microscopy with conducting polymer probes: Validation and applications. Anal Chim Acta 2019; 1069:36-46. [PMID: 31084739 DOI: 10.1016/j.aca.2019.04.022] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2018] [Revised: 04/05/2019] [Accepted: 04/09/2019] [Indexed: 02/05/2023]
Abstract
Scanning electrochemical microscopy (SECM) allows spatially and temporally resolved measurements of a broad range of reactive surfaces and specimens, typically using electrochemically active metal probes. While conducting polymers (CPs) present several analytical properties of interest due to their chemical versatility, potentially enabling the measurement of ionic fluxes as well as redox processes, they have not been widely used as probe materials for SECM. CPs can be modified and fine-tuned to improve experimental parameters and they can be easily prepared by electrodeposition. In this paper, we show a new type of CP probe for SECM that retains the spatial resolution of conventional metal probes and introduces the possibility to exploit a wide range of ionic and redox systems. Poly-3,4-ethylenedioxythiophene (PEDOT) was electrochemically deposited on flat and recessed Pt microdisks to generate CP SECM probes. To demonstrate their usefulness, an insulating substrate with conducting features was imaged. Well-defined SECM feedback images were observed for both the CP well-probe and the Pt probe, proving the efficiency of the new electrode to image redox reactions. Additionally, an organosulfur compound was used as mediator taking advantage of the electrocatalytic effect PEDOT has on the molecule's kinetics. Finally, these probes were also used in a mediator-less fashion, taking advantage of the ion flux required to electrochemically oxidize the PEDOT deposit. We investigated the impact of anion size and concentration on current-distance relationships for SECM probe positioning. CP probes pose exciting prospects for the imaging and measurement of combined redox and ionic processes in energy materials.
Collapse
Affiliation(s)
- Marie A Claudio-Cintrón
- Department of Chemistry, University of Illinois at Urbana-Champaign, 600 South Mathews Avenue, Urbana, IL, 61801, United States
| | - Joaquín Rodríguez-López
- Department of Chemistry, University of Illinois at Urbana-Champaign, 600 South Mathews Avenue, Urbana, IL, 61801, United States.
| |
Collapse
|
13
|
Zhao W, Song W, Cheong LZ, Wang D, Li H, Besenbacher F, Huang F, Shen C. Beyond imaging: Applications of atomic force microscopy for the study of Lithium-ion batteries. Ultramicroscopy 2019; 204:34-48. [DOI: 10.1016/j.ultramic.2019.05.004] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2018] [Revised: 03/19/2019] [Accepted: 05/12/2019] [Indexed: 12/22/2022]
|
14
|
Sandford C, Edwards MA, Klunder KJ, Hickey DP, Li M, Barman K, Sigman MS, White HS, Minteer SD. A synthetic chemist's guide to electroanalytical tools for studying reaction mechanisms. Chem Sci 2019; 10:6404-6422. [PMID: 31367303 PMCID: PMC6615219 DOI: 10.1039/c9sc01545k] [Citation(s) in RCA: 180] [Impact Index Per Article: 36.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2019] [Accepted: 05/23/2019] [Indexed: 12/19/2022] Open
Abstract
Monitoring reactive intermediates can provide vital information in the study of synthetic reaction mechanisms, enabling the design of new catalysts and methods. Many synthetic transformations are centred on the alteration of oxidation states, but these redox processes frequently pass through intermediates with short life-times, making their study challenging. A variety of electroanalytical tools can be utilised to investigate these redox-active intermediates: from voltammetry to in situ spectroelectrochemistry and scanning electrochemical microscopy. This perspective provides an overview of these tools, with examples of both electrochemically-initiated processes and monitoring redox-active intermediates formed chemically in solution. The article is designed to introduce synthetic organic and organometallic chemists to electroanalytical techniques and their use in probing key mechanistic questions.
Collapse
Affiliation(s)
- Christopher Sandford
- Department of Chemistry , University of Utah , 315 South 1400 East , Salt Lake City , Utah 84112 , USA . ; ;
| | - Martin A Edwards
- Department of Chemistry , University of Utah , 315 South 1400 East , Salt Lake City , Utah 84112 , USA . ; ;
| | - Kevin J Klunder
- Department of Chemistry , University of Utah , 315 South 1400 East , Salt Lake City , Utah 84112 , USA . ; ;
| | - David P Hickey
- Department of Chemistry , University of Utah , 315 South 1400 East , Salt Lake City , Utah 84112 , USA . ; ;
| | - Min Li
- Department of Chemistry , University of Utah , 315 South 1400 East , Salt Lake City , Utah 84112 , USA . ; ;
| | - Koushik Barman
- Department of Chemistry , University of Utah , 315 South 1400 East , Salt Lake City , Utah 84112 , USA . ; ;
| | - Matthew S Sigman
- Department of Chemistry , University of Utah , 315 South 1400 East , Salt Lake City , Utah 84112 , USA . ; ;
| | - Henry S White
- Department of Chemistry , University of Utah , 315 South 1400 East , Salt Lake City , Utah 84112 , USA . ; ;
| | - Shelley D Minteer
- Department of Chemistry , University of Utah , 315 South 1400 East , Salt Lake City , Utah 84112 , USA . ; ;
| |
Collapse
|
15
|
Astrauskas R, Ivanauskas F, Morkvenaite‐Vilkonciene I, Ramanavicius A. Mathematical Modelling of the Influence of Ultra‐micro Electrode Geometry on Approach Curves Registered by Scanning Electrochemical Microscopy. ELECTROANAL 2019. [DOI: 10.1002/elan.201900313] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Affiliation(s)
- Rokas Astrauskas
- Institute of Computer Science, Faculty of Mathematics and InformaticsVilnius University, Didlaukio 47 Vilnius Lithuania
| | - Feliksas Ivanauskas
- Institute of Computer Science, Faculty of Mathematics and InformaticsVilnius University, Didlaukio 47 Vilnius Lithuania
| | - Inga Morkvenaite‐Vilkonciene
- Department of Mechatronics and RoboticsVilnius Gediminas Technical University, J. Basanaviciaus 28 03224 Vilnius Lithuania
- Department of Electrochemical Material ScienceState Research Institute Centre for Physical Sciences and Technology, Sauletekio 3 Vilnius Lithuania
| | - Arunas Ramanavicius
- Department of Physical Chemistry, Faculty of ChemistryVilnius University, Naugarduko 24 Vilnius Lithuania
- Laboratory of BionanotechnologyState Research Institute Centre for Physical Sciences and Technology, Sauletekio 3 Vilnius Lithuania
| |
Collapse
|
16
|
Marshall RC, Whitworth DE. Is "Wolf-Pack" Predation by Antimicrobial Bacteria Cooperative? Cell Behaviour and Predatory Mechanisms Indicate Profound Selfishness, Even when Working Alongside Kin. Bioessays 2019; 41:e1800247. [PMID: 30919490 DOI: 10.1002/bies.201800247] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2018] [Revised: 02/10/2019] [Indexed: 01/27/2023]
Abstract
For decades, myxobacteria have been spotlighted as exemplars of social "wolf-pack" predation, communally secreting antimicrobial substances into the shared public milieu. This behavior has been described as cooperative, becoming more efficient if performed by more cells. However, laboratory evidence for cooperativity is limited and of little relevance to predation in a natural setting. In contrast, there is accumulating evidence for predatory mechanisms promoting "selfish" behavior during predation, which together with conflicting definitions of cooperativity, casts doubt on whether microbial "wolf-pack" predation really is cooperative. Here, it is hypothesized that public-goods-mediated predation is not cooperative, and it is argued that a holistic model of microbial predation is needed, accounting for predator and prey relatedness, social phenotypes, spatial organization, activity/specificity/transport of secreted toxins, and prey resistance mechanisms. Filling such gaps in our knowledge is vital if the evolutionary benefits of potentially costly microbial behaviors mediated by public goods are to be properly understood.
Collapse
Affiliation(s)
- Rupert C Marshall
- Institute of Biological, Environmental and Rural Sciences, Aberystwyth University, Aberystwyth, Ceredigion SY23 3DA, UK
| | - David E Whitworth
- Institute of Biological, Environmental and Rural Sciences, Aberystwyth University, Aberystwyth, Ceredigion SY23 3DA, UK
| |
Collapse
|
17
|
Conzuelo F, Schulte A, Schuhmann W. Biological imaging with scanning electrochemical microscopy. Proc Math Phys Eng Sci 2018; 474:20180409. [PMID: 30839832 PMCID: PMC6237495 DOI: 10.1098/rspa.2018.0409] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2018] [Accepted: 09/04/2018] [Indexed: 12/27/2022] Open
Abstract
Scanning electrochemical microscopy (SECM) is a powerful and versatile technique for visualizing the local electrochemical activity of a surface as an ultramicroelectrode tip is moved towards or over a sample of interest using precise positioning systems. In comparison with other scanning probe techniques, SECM not only enables topographical surface mapping but also gathers chemical information with high spatial resolution. Considerable progress has been made in the analysis of biological samples, including living cells and immobilized biomacromolecules such as enzymes, antibodies and DNA fragments. Moreover, combinations of SECM with comple-mentary analytical tools broadened its applicability and facilitated multi-functional analysis with extended life science capabilities. The aim of this review is to present a brief topical overview on recent applications of biological SECM, with particular emphasis on important technical improvements of this surface imaging technique, recommended applications and future trends.
Collapse
Affiliation(s)
- Felipe Conzuelo
- Analytical Chemistry—Center for Electrochemical Sciences (CES), Faculty for Chemistry and Biochemistry, Ruhr-Universität Bochum, Universitätsstr. 150, 44780 Bochum, Germany
| | - Albert Schulte
- School of Biomolecular Science and Engineering (BSE), Vidyasirimedhi Institute of Science and Technology (VISTEC), Rayong 21210, Thailand
| | - Wolfgang Schuhmann
- Analytical Chemistry—Center for Electrochemical Sciences (CES), Faculty for Chemistry and Biochemistry, Ruhr-Universität Bochum, Universitätsstr. 150, 44780 Bochum, Germany
| |
Collapse
|
18
|
Huang L, Li Z, Lou Y, Cao F, Zhang D, Li X. Recent Advances in Scanning Electrochemical Microscopy for Biological Applications. MATERIALS (BASEL, SWITZERLAND) 2018; 11:E1389. [PMID: 30096895 PMCID: PMC6119995 DOI: 10.3390/ma11081389] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/25/2018] [Revised: 07/24/2018] [Accepted: 07/28/2018] [Indexed: 12/17/2022]
Abstract
Scanning electrochemical microscopy (SECM) is a chemical microscopy technique with high spatial resolution for imaging sample topography and mapping specific chemical species in liquid environments. With the development of smaller, more sensitive ultramicroelectrodes (UMEs) and more precise computer-controlled measurements, SECM has been widely used to study biological systems over the past three decades. Recent methodological breakthroughs have popularized SECM as a tool for investigating molecular-level chemical reactions. The most common applications include monitoring and analyzing the biological processes associated with enzymatic activity and DNA, and the physiological activity of living cells and other microorganisms. The present article first introduces the basic principles of SECM, followed by an updated review of the applications of SECM in biological studies on enzymes, DNA, proteins, and living cells. Particularly, the potential of SECM for investigating bacterial and biofilm activities is discussed.
Collapse
Affiliation(s)
- Luyao Huang
- Institute for Advanced Materials and Technology, University of Science and Technology Beijing, Beijing 100083, China.
| | - Ziyu Li
- Institute for Advanced Materials and Technology, University of Science and Technology Beijing, Beijing 100083, China.
| | - Yuntian Lou
- Institute for Advanced Materials and Technology, University of Science and Technology Beijing, Beijing 100083, China.
| | - Fahe Cao
- Department of Chemistry, Zhejiang University, Hangzhou 310027, China.
| | - Dawei Zhang
- Institute for Advanced Materials and Technology, University of Science and Technology Beijing, Beijing 100083, China.
| | - Xiaogang Li
- Institute for Advanced Materials and Technology, University of Science and Technology Beijing, Beijing 100083, China.
| |
Collapse
|
19
|
Zhao F, Conzuelo F, Hartmann V, Li H, Stapf S, Nowaczyk MM, Rögner M, Plumeré N, Lubitz W, Schuhmann W. A novel versatile microbiosensor for local hydrogen detection by means of scanning photoelectrochemical microscopy. Biosens Bioelectron 2017; 94:433-437. [PMID: 28334627 DOI: 10.1016/j.bios.2017.03.037] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2016] [Revised: 03/15/2017] [Accepted: 03/17/2017] [Indexed: 11/25/2022]
Abstract
The development of a versatile microbiosensor for hydrogen detection is reported. Carbon-based microelectrodes were modified with a [NiFe]-hydrogenase embedded in a viologen-modified redox hydrogel for the fabrication of a sensitive hydrogen biosensor By integrating the microbiosensor in a scanning photoelectrochemical microscope, it was capable of serving simultaneously as local light source to initiate photo(bio)electrochemical reactions while acting as sensitive biosensor for the detection of hydrogen. A hydrogen evolution biocatalyst based on photosystem 1-platinum nanoparticle biocomplexes embedded into a specifically designed redox polymer was used as a model for proving the capability of the developed hydrogen biosensor for the detection of hydrogen upon localized illumination. The versatility and sensitivity of the proposed microbiosensor as probe tip allows simplification of the set-up used for the evaluation of complex electrochemical processes and the rapid investigation of local photoelectrocatalytic activity of biocatalysts towards light-induced hydrogen evolution.
Collapse
Affiliation(s)
- Fangyuan Zhao
- Analytical Chemistry - Center for Electrochemical Sciences (CES), Ruhr-Universität Bochum, Universitätsstr. 150, D-44780 Bochum, Germany
| | - Felipe Conzuelo
- Analytical Chemistry - Center for Electrochemical Sciences (CES), Ruhr-Universität Bochum, Universitätsstr. 150, D-44780 Bochum, Germany
| | - Volker Hartmann
- Plant Biochemistry, Ruhr-Universität Bochum, Universitätsstr. 150, D-44780 Bochum, Germany
| | - Huaiguang Li
- Center for Electrochemical Sciences - Molecular Nanostructures, Ruhr-Universität Bochum, Universitätsstr. 150, D-44780 Bochum, Germany
| | - Stefanie Stapf
- Center for Electrochemical Sciences - Molecular Nanostructures, Ruhr-Universität Bochum, Universitätsstr. 150, D-44780 Bochum, Germany
| | - Marc M Nowaczyk
- Plant Biochemistry, Ruhr-Universität Bochum, Universitätsstr. 150, D-44780 Bochum, Germany
| | - Matthias Rögner
- Plant Biochemistry, Ruhr-Universität Bochum, Universitätsstr. 150, D-44780 Bochum, Germany
| | - Nicolas Plumeré
- Center for Electrochemical Sciences - Molecular Nanostructures, Ruhr-Universität Bochum, Universitätsstr. 150, D-44780 Bochum, Germany
| | - Wolfgang Lubitz
- Max Planck Institut für Chemische Energiekonversion, Stiftstrasse 34-36, D-45470 Mülheim an der Ruhr, Germany
| | - Wolfgang Schuhmann
- Analytical Chemistry - Center for Electrochemical Sciences (CES), Ruhr-Universität Bochum, Universitätsstr. 150, D-44780 Bochum, Germany.
| |
Collapse
|
20
|
Polcari D, Dauphin-Ducharme P, Mauzeroll J. Scanning Electrochemical Microscopy: A Comprehensive Review of Experimental Parameters from 1989 to 2015. Chem Rev 2016; 116:13234-13278. [PMID: 27736057 DOI: 10.1021/acs.chemrev.6b00067] [Citation(s) in RCA: 213] [Impact Index Per Article: 26.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Affiliation(s)
- David Polcari
- Department
of Chemistry, McGill University, 801 Sherbrooke Street West, Montreal, Quebec Canada, H3A 0B8
| | - Philippe Dauphin-Ducharme
- Department
of Chemistry, McGill University, 801 Sherbrooke Street West, Montreal, Quebec Canada, H3A 0B8
| | - Janine Mauzeroll
- Department
of Chemistry, McGill University, 801 Sherbrooke Street West, Montreal, Quebec Canada, H3A 0B8
| |
Collapse
|
21
|
|
22
|
Zhang MN, Ding Z, Long YT. Sensing cisplatin-induced permeation of single live human bladder cancer cells by scanning electrochemical microscopy. Analyst 2016; 140:6054-60. [PMID: 26194058 DOI: 10.1039/c5an01148e] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Cisplatin is a widely used anti-cancer agent, which was believed to trigger apoptosis of cancer cells by forming DNA adducts. However, recent studies evidenced a cisplatin-induced extrinsic apoptotic pathway through interaction with plasma membranes. We present quantitative time-course imaging of cisplatin-induced permeation of ferrocenemethanol to single live human bladder cancer cells (T24) using scanning electrochemical microscopy (SECM). Simultaneous quantification of cellular topography and membrane permeability was realized by running SECM in the depth scan mode. It was demonstrated that the acute addition of cisplatin to the outer environment of T24 cells immediately induced membrane permeability change in 5 min, which indicated a loosened structure of the cellular membrane upon cisplatin dosage. The cisplatin-induced permeation of T24 cells might be a one-step action, an extrinsic mechanism, since the cell response was quick, and no continuous increase in the membrane permeability was observed. The time-lapse SECM depth scan method provided a simple and facile way of monitoring cisplatin-induced membrane permeability changes. Our study is anticipated to lead to a methodology of screening anti-cancer drugs through their interactions with live cells.
Collapse
Affiliation(s)
- Meng-Ni Zhang
- Department of Chemistry, The University of Western Ontario, London, ON, Canada N6A 5B7.
| | | | | |
Collapse
|
23
|
Ventosa E, Schuhmann W. Scanning electrochemical microscopy of Li-ion batteries. Phys Chem Chem Phys 2016; 17:28441-50. [PMID: 26076998 DOI: 10.1039/c5cp02268a] [Citation(s) in RCA: 69] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Li-ion batteries (LIBs) are receiving increasing attention over the past decade due to their high energy density. This energy storage technology is expected to continue improving the performance, especially for its large-scale deployment in plug-in hybrid electric vehicles (PHEVs) and full electric vehicles (EVs). Such improvement requires having a large variety of analytical techniques at scientists' disposal in order to understand and address the multiple mechanisms and processes occurring simultaneously in this complex system. This perspective article aims to highlight the strength and potential of scanning electrochemical microscopy (SECM) in this field. After a brief description of a LIB system and the most commonly used techniques in this field, the unique information provided by SECM is illustrated by discussing several recent examples from the literature.
Collapse
Affiliation(s)
- E Ventosa
- Analytische Chemie - Center for Electrochemical Sciences (CES), Ruhr-Universität Bochum, Universitätstr. 150, D-44780 Bochum, Germany.
| | - W Schuhmann
- Analytische Chemie - Center for Electrochemical Sciences (CES), Ruhr-Universität Bochum, Universitätstr. 150, D-44780 Bochum, Germany.
| |
Collapse
|
24
|
Characterization of local electrocatalytical activity of nanosheet-structured ZnCo 2 O 4 /carbon nanotubes composite for oxygen reduction reaction with scanning electrochemical microscopy. Electrochim Acta 2015. [DOI: 10.1016/j.electacta.2015.08.060] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
|
25
|
Mohamad NR, Marzuki NHC, Buang NA, Huyop F, Wahab RA. An overview of technologies for immobilization of enzymes and surface analysis techniques for immobilized enzymes. BIOTECHNOL BIOTEC EQ 2015; 29:205-220. [PMID: 26019635 PMCID: PMC4434042 DOI: 10.1080/13102818.2015.1008192] [Citation(s) in RCA: 707] [Impact Index Per Article: 78.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2014] [Accepted: 10/07/2014] [Indexed: 01/28/2023] Open
Abstract
The current demands of sustainable green methodologies have increased the use of enzymatic technology in industrial processes. Employment of enzyme as biocatalysts offers the benefits of mild reaction conditions, biodegradability and catalytic efficiency. The harsh conditions of industrial processes, however, increase propensity of enzyme destabilization, shortening their industrial lifespan. Consequently, the technology of enzyme immobilization provides an effective means to circumvent these concerns by enhancing enzyme catalytic properties and also simplify downstream processing and improve operational stability. There are several techniques used to immobilize the enzymes onto supports which range from reversible physical adsorption and ionic linkages, to the irreversible stable covalent bonds. Such techniques produce immobilized enzymes of varying stability due to changes in the surface microenvironment and degree of multipoint attachment. Hence, it is mandatory to obtain information about the structure of the enzyme protein following interaction with the support surface as well as interactions of the enzymes with other proteins. Characterization technologies at the nanoscale level to study enzymes immobilized on surfaces are crucial to obtain valuable qualitative and quantitative information, including morphological visualization of the immobilized enzymes. These technologies are pertinent to assess efficacy of an immobilization technique and development of future enzyme immobilization strategies.
Collapse
Affiliation(s)
- Nur Royhaila Mohamad
- Department of Chemistry, Faculty of Science, Universiti Teknologi Malaysia, Skudai81310, Johor, Malaysia
| | - Nur Haziqah Che Marzuki
- Department of Chemistry, Faculty of Science, Universiti Teknologi Malaysia, Skudai81310, Johor, Malaysia
| | - Nor Aziah Buang
- Department of Chemistry, Faculty of Science, Universiti Teknologi Malaysia, Skudai81310, Johor, Malaysia
| | - Fahrul Huyop
- Department of Biotechnology and Medical Engineering, Faculty of Bioscience and Medical Engineering, Universiti Teknologi Malaysia, Skudai81310, Johor, Malaysia
| | - Roswanira Abdul Wahab
- Department of Chemistry, Faculty of Science, Universiti Teknologi Malaysia, Skudai81310, Johor, Malaysia
| |
Collapse
|
26
|
Kanno Y, Ino K, Inoue KY, Şen M, Suda A, Kunikata R, Matsudaira M, Abe H, Li CZ, Shiku H, Matsue T. Feedback mode-based electrochemical imaging of conductivity and topography for large substrate surfaces using an LSI-based amperometric chip device with 400 sensors. J Electroanal Chem (Lausanne) 2015. [DOI: 10.1016/j.jelechem.2015.01.020] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
|
27
|
Real-time mapping of salt glands on the leaf surface of Cynodon dactylon L. using scanning electrochemical microscopy. Bioelectrochemistry 2015; 101:159-64. [DOI: 10.1016/j.bioelechem.2014.10.004] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2013] [Revised: 10/06/2014] [Indexed: 11/19/2022]
|
28
|
Jo H, Theato P. Post-polymerization Modification of Surface-Bound Polymers. CONTROLLED RADICAL POLYMERIZATION AT AND FROM SOLID SURFACES 2015. [DOI: 10.1007/12_2015_315] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
|
29
|
O’Connell MA, Wain AJ. Mapping Electroactivity at Individual Catalytic Nanostructures Using High-Resolution Scanning Electrochemical–Scanning Ion Conductance Microcopy. Anal Chem 2014; 86:12100-7. [DOI: 10.1021/ac502946q] [Citation(s) in RCA: 53] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Affiliation(s)
| | - Andrew J. Wain
- National Physical Laboratory, Hampton Road, Teddington TW11 0LW, United Kingdom
| |
Collapse
|
30
|
Luo H, Dong C, Gao S, Du C, Xiao K, Li X. Sensing application in the precursor region of localized corrosion by scanning electrochemical microscopy. RSC Adv 2014. [DOI: 10.1039/c4ra01734j] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
|
31
|
Hüske M, Stockmann R, Offenhäusser A, Wolfrum B. Redox cycling in nanoporous electrochemical devices. NANOSCALE 2014; 6:589-598. [PMID: 24247480 DOI: 10.1039/c3nr03818a] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
Nanoscale redox cycling is a powerful technique for detecting electrochemically active molecules, based on fast repetitive oxidation and reduction reactions. An ideal implementation of redox cycling sensors can be realized by nanoporous dual-electrode systems in easily accessible and scalable geometries. Here, we introduce a multi-electrode array device with highly efficient nanoporous redox cycling sensors. Each of the sensors holds up to 209,000 well defined nanopores with minimal pore radii of less than 40 nm and an electrode separation of ~100 nm. We demonstrate the efficiency of the nanopore array by screening a large concentration range over three orders of magnitude with area-specific sensitivities of up to 81.0 mA (cm(-2) mM(-1)) for the redox-active probe ferrocene dimethanol. Furthermore, due to the specific geometry of the material, reaction kinetics has a unique potential-dependent impact on the signal characteristics. As a result, redox cycling experiments in the nanoporous structure allow studies on heterogeneous electron transfer reactions revealing a surprisingly asymmetric transfer coefficient.
Collapse
Affiliation(s)
- Martin Hüske
- Institute of Bioelectronics (PGI-8/ICS-8) and JARA-Fundamentals of Future Information Technology, Forschungszentrum Jülich, D-52425 Jülich, Germany.
| | | | | | | |
Collapse
|
32
|
Hüske M, Offenhäusser A, Wolfrum B. Nanoporous dual-electrodes with millimetre extensions: parallelized fabrication and area effects on redox cycling. Phys Chem Chem Phys 2014; 16:11609-16. [DOI: 10.1039/c4cp01027b] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Novel fabrication techniques lead to highly sensitive electrochemical sensors (left). The large-area characteristics of redox-cycling within the sensor's nanopores further cause potential-dependent variations of the overall analyte concentration (right).
Collapse
Affiliation(s)
- Martin Hüske
- Institute of Bioelectronics (PGI-8/ICS-8) and JARA—Fundamentals of Future Information Technology
- For-schungszentrum Jülich
- D-52425 Jülich, Germany
| | - Andreas Offenhäusser
- Institute of Bioelectronics (PGI-8/ICS-8) and JARA—Fundamentals of Future Information Technology
- For-schungszentrum Jülich
- D-52425 Jülich, Germany
- IV. Institute of Physics
- RWTH Aachen University
| | - Bernhard Wolfrum
- Institute of Bioelectronics (PGI-8/ICS-8) and JARA—Fundamentals of Future Information Technology
- For-schungszentrum Jülich
- D-52425 Jülich, Germany
- IV. Institute of Physics
- RWTH Aachen University
| |
Collapse
|
33
|
McKelvey K, Martin S, Robinson C, Unwin PR. Quantitative local photosynthetic flux measurements at isolated chloroplasts and thylakoid membranes using scanning electrochemical microscopy (SECM). J Phys Chem B 2013; 117:7878-88. [PMID: 23751155 DOI: 10.1021/jp403048f] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Scanning electrochemical microscopy (SECM) offers a fast and quantitative method to measure local fluxes within photosynthesis. In particular, we have measured the flux of oxygen and ferrocyanide (Fe(CN)6(4-)), from the artificial electron acceptor ferricyanide (Fe(CN)6(3-)), using a stationary ultramicroelectrode at chloroplasts and thylakoid membranes (sourced from chloroplasts). Oxygen generation at films of chloroplasts and thylakoid membranes was detected directly during photosynthesis, but in the case of thylakoid membranes, this switched to sustained oxygen consumption at longer illumination times. An initial oxygen concentration spike was detected over both chloroplast and thylakoid membrane films, and the kinetics of the oxygen generation were extracted by fitting the experimental data to a finite element method (FEM) simulation. In contrast to previous work, the oxygen generation spike was attributed to the limited size of the plastoquinone pool, a key component in the linear electron transport pathway and a contributing factor in photoinhibition. Finally, the mobile nature of the SECM probe, and its high spatial resolution, also allowed us to detect ferrocyanide produced from a single thylakoid membrane. These results further demonstrate the power of SECM for localized flux measurements in biological processes, in this case photosynthesis, and that the high time resolution, combined with FEM simulations, allows the elucidation of quantitative kinetic information.
Collapse
Affiliation(s)
- Kim McKelvey
- Department of Chemistry, University of Warwick, Coventry, UK CV4 7AL
| | | | | | | |
Collapse
|
34
|
Gasiorowski J, Mardare AI, Sariciftci NS, Hassel AW. Electrochemical characterization of sub-micro-gram amounts of organic semiconductors using scanning droplet cell microscopy. J Electroanal Chem (Lausanne) 2013; 691:77-82. [PMID: 24926226 PMCID: PMC4047611 DOI: 10.1016/j.jelechem.2012.11.008] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2012] [Revised: 11/05/2012] [Accepted: 11/07/2012] [Indexed: 11/26/2022]
Abstract
Scanning droplet cell microscopy (SDCM) uses a very small electrolyte droplet at the tip of a capillary which comes in contact with the working electrode. This method is particularly interesting for studies on organic semiconductors since it provides localized electrochemical investigations with high reproducibility. One clear advantage of applying SDCM is represented by the very small amounts of material necessary (less than 1 mg). Organic materials can be investigated quickly and inexpensively in electrochemical studies with a high throughput. In the present study, thin layers of poly(3-hexylthiophene) (P3HT), which is one of the most often used material for organic solar cells, were deposited on ITO/glass as working electrodes in SDCM studies. The redox reactions in 0.1 M tetra(n-butyl)ammonium hexafluorophosphate (TBAPF6) dissolved in propylene carbonate were studied by cyclic voltammetry and by electrochemical impedance spectroscopy. Two reversible, distinct oxidation steps of the P3HT were detected and their kinetics were studied in detail. The doping of P3HT increased due to the electrochemical oxidation and had resulted in a decrease of the film resistance by a few orders of magnitude. Due to localization on the sample various parameter combinations can be studied quantitatively and reproducibly.
Collapse
Affiliation(s)
- Jacek Gasiorowski
- Linz Institute for Organic Solar Cells (LIOS), Physical Chemistry, Johannes Kepler University, Linz, Austria
| | - Andrei I. Mardare
- Institute for Chemical Technology of Inorganic Materials, Johannes Kepler University, Linz, Austria
| | - Niyazi S. Sariciftci
- Linz Institute for Organic Solar Cells (LIOS), Physical Chemistry, Johannes Kepler University, Linz, Austria
| | - Achim Walter Hassel
- Institute for Chemical Technology of Inorganic Materials, Johannes Kepler University, Linz, Austria
| |
Collapse
|
35
|
Ebejer N, Güell AG, Lai SCS, McKelvey K, Snowden ME, Unwin PR. Scanning electrochemical cell microscopy: a versatile technique for nanoscale electrochemistry and functional imaging. ANNUAL REVIEW OF ANALYTICAL CHEMISTRY (PALO ALTO, CALIF.) 2013; 6:329-51. [PMID: 23560932 DOI: 10.1146/annurev-anchem-062012-092650] [Citation(s) in RCA: 177] [Impact Index Per Article: 16.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
Scanning electrochemical cell microscopy (SECCM) is a new pipette-based imaging technique purposely designed to allow simultaneous electrochemical, conductance, and topographical visualization of surfaces and interfaces. SECCM uses a tiny meniscus or droplet, at the end of a double-barreled (theta) pipette, for high-resolution functional imaging and nanoscale electrochemical measurements. Here we introduce this technique and provide an overview of its principles, instrumentation, and theory. We discuss the power of SECCM in resolving complex structure-activity problems and provide considerable new information on electrode processes by referring to key example systems, including graphene, graphite, carbon nanotubes, nanoparticles, and conducting diamond. The many longstanding questions that SECCM has been able to answer during its short existence demonstrate its potential to become a major technique in electrochemistry and interfacial science.
Collapse
Affiliation(s)
- Neil Ebejer
- Department of Chemistry, University ofWarwick, Coventry CV4 7AL, United Kingdom
| | | | | | | | | | | |
Collapse
|
36
|
Abstract
The requirements for early diagnostics as well as effective treatment of insidious diseases such as cancer constantly increase the pressure on development of efficient and reliable methods for targeted drug/gene delivery as well as imaging of the treatment success/failure. One of the most recent approaches covering both the drug delivery as well as the imaging aspects is benefitting from the unique properties of nanomaterials. Therefore a new field called nanomedicine is attracting continuously growing attention. Nanoparticles, including fluorescent semiconductor nanocrystals (quantum dots) and magnetic nanoparticles, have proven their excellent properties for in vivo imaging techniques in a number of modalities such as magnetic resonance and fluorescence imaging, respectively. In this article, we review the main properties and applications of nanoparticles in various in vitro imaging techniques, including microscopy and/or laser breakdown spectroscopy and in vivo methods such as magnetic resonance imaging and/or fluorescence-based imaging. Moreover the advantages of the drug delivery performed by nanocarriers such as iron oxides, gold, biodegradable polymers, dendrimers, lipid based carriers such as liposomes or micelles are also highlighted.
Collapse
|
37
|
SECM detection of single boron doped diamond nanodes and nanoelectrode arrays using phase-operated shear force technique. Electrochem commun 2012. [DOI: 10.1016/j.elecom.2012.08.005] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
|
38
|
Patten HV, Lai SCS, Macpherson JV, Unwin PR. Active sites for outer-sphere, inner-sphere, and complex multistage electrochemical reactions at polycrystalline boron-doped diamond electrodes (pBDD) revealed with scanning electrochemical cell microscopy (SECCM). Anal Chem 2012; 84:5427-32. [PMID: 22607491 DOI: 10.1021/ac3010555] [Citation(s) in RCA: 61] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
Abstract
The local rate of heterogeneous electron transfer (HET) at polycrystalline boron-doped diamond (pBDD) electrodes has been visualized at high spatial resolution for various aqueous electrochemical reactions, using scanning electrochemical cell microscopy (SECCM), which is a technique that uses a mobile pipet-based electrochemical cell as an imaging probe. As exemplar systems, three important classes of electrode reactions have been investigated: outer-sphere (one-electron oxidation of ferrocenylmethyltrimethylammonium (FcTMA(+))), inner-sphere (one-electron oxidation of Fe(2+)), and complex processes with coupled electron transfer and chemical reactions (oxidation of serotonin). In all cases, the pattern of reactivity is similar: the entire pBDD surface is electroactive, but there are variations in activity between different crystal facets which correlate directly with differences in the local dopant level, as visualized qualitatively by field-emission scanning electron microscopy (FE-SEM). No evidence was found for enhanced activity at grain boundaries for any of the reactions. The case of serotonin oxidation is particularly interesting, as this process is known to lead to deterioration of the electrodes, because of blocking by reaction products, and therefore cannot be studied with conventional scanning electrochemical probe microscopy (SEPM) techniques. Yet, we have found this system nonproblematic to study, because the meniscus of the scanning pipet is only in contact with the surface investigated for a brief time and any blocking product is left behind as the pipet moves to a new location. Thus, SECCM opens up the possibility of investigating and visualizing much more complex heterogeneous electrode reactions than possible presently with other SEPM techniques.
Collapse
Affiliation(s)
- Hollie V Patten
- Department of Chemistry, University of Warwick, Coventry CV4 7AL, United Kingdom
| | | | | | | |
Collapse
|
39
|
|
40
|
McKelvey K, Snowden ME, Peruffo M, Unwin PR. Quantitative Visualization of Molecular Transport through Porous Membranes: Enhanced Resolution and Contrast Using Intermittent Contact-Scanning Electrochemical Microscopy. Anal Chem 2011; 83:6447-54. [DOI: 10.1021/ac201489c] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Affiliation(s)
- Kim McKelvey
- MOAC Doctoral Training Centre and ‡Department of Chemistry, University of Warwick, Coventry, U.K. CV4 7AL
| | - Michael E. Snowden
- MOAC Doctoral Training Centre and ‡Department of Chemistry, University of Warwick, Coventry, U.K. CV4 7AL
| | - Massimo Peruffo
- MOAC Doctoral Training Centre and ‡Department of Chemistry, University of Warwick, Coventry, U.K. CV4 7AL
| | - Patrick R. Unwin
- MOAC Doctoral Training Centre and ‡Department of Chemistry, University of Warwick, Coventry, U.K. CV4 7AL
| |
Collapse
|
41
|
Trinh D, Keddam M, Novoa XR, Vivier V. Alternating Current Measurements in Scanning Electrochemical Microscopy, Part 2: Detection of Adsorbates. Chemphyschem 2011; 12:2177-83. [DOI: 10.1002/cphc.201001085] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2010] [Revised: 04/13/2011] [Indexed: 11/09/2022]
|
42
|
Edwards MA, Whitworth AL, Unwin PR. Quantitative Analysis and Application of Tip Position Modulation-Scanning Electrochemical Microscopy. Anal Chem 2011; 83:1977-84. [DOI: 10.1021/ac102680v] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
- Martin A. Edwards
- Department of Chemistry, University of Warwick, Gibbet Hill Road, Coventry, CV4 7AL, U.K
- Molecular Organisation and Assembly in Cells Doctoral Training Centre, University of Warwick, Gibbet Hill Road, Coventry, CV4 7AL, U.K
| | - Anna L. Whitworth
- Department of Chemistry, University of Warwick, Gibbet Hill Road, Coventry, CV4 7AL, U.K
| | - Patrick R. Unwin
- Department of Chemistry, University of Warwick, Gibbet Hill Road, Coventry, CV4 7AL, U.K
| |
Collapse
|
43
|
Castro PS, Lima AS, Ferreira TL, Bertotti M. Scanning Electrochemical Microscopy as a Tool for the Characterization of Dental Erosion. INTERNATIONAL JOURNAL OF ELECTROCHEMISTRY 2011. [DOI: 10.4061/2011/952470] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
When the tooth is exposed to acidic environments, an irreversible loss of dental hard tissue occurs in a process called dental erosion. In this work, the scanning electrochemical microscopy (SECM) was used to probe the consumption of protons at the vicinity of a tooth surface with a platinum microelectrode fixed at −0.5 (V) versus Ag/AgCl/KCl(sat). SECM approach curves were recorded to assess the extent of diffusion in the solution close to the tooth substrate. SECM images clearly demonstrated that the acid erosion process is very fast at solution pH values in the range between 3 and 4.
Collapse
Affiliation(s)
- Pollyana S. Castro
- Instituto de Química, Universidade de São Paulo (USP), 05508-900 São Paulo, SP, Brazil
| | - Alex S. Lima
- Instituto de Química, Universidade de São Paulo (USP), 05508-900 São Paulo, SP, Brazil
| | - Tiago L. Ferreira
- Instituto de Ciências Ambientais, Químicas e Farmacêuticas, Universidade Federal de São Paulo (UNIFESP), Campus Diadema, 09972-270 Diadema, SP, Brazil
| | - Mauro Bertotti
- Instituto de Química, Universidade de São Paulo (USP), 05508-900 São Paulo, SP, Brazil
| |
Collapse
|
44
|
McKelvey K, Edwards MA, Unwin PR. Intermittent contact-scanning electrochemical microscopy (IC-SECM): a new approach for tip positioning and simultaneous imaging of interfacial topography and activity. Anal Chem 2010; 82:6334-7. [PMID: 20583818 DOI: 10.1021/ac101099e] [Citation(s) in RCA: 66] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
A new scanning electrochemical microscopy (SECM) tip positioning method that allows surface topography and activity to be resolved simultaneously and independently is presented. The tip, controlled by a piezoelectric positioner operated in closed loop, is oscillated normal to the substrate surface. Changes in the oscillation amplitude, caused by the intermittent contact (IC) of the tip with the substrate surface, are used as a feedback signal to control the tip height. The method is illustrated with amperometric feedback approach curve measurements to inert (insulating) and active (conducting) substrates using 12.5 and 1 microm radii Pt disk electrodes. Imaging of gold bands on a glass substrate demonstrates the capabilities for simultaneous topography and activity mapping. The prospect for using IC methodology more widely with other types of tips is highlighted briefly.
Collapse
Affiliation(s)
- Kim McKelvey
- Department of Chemistry and MOAC Doctoral Training Centre, University of Warwick, Coventry, UK CV4 7AL
| | | | | |
Collapse
|
45
|
McGeouch CA, Edwards MA, Mbogoro MM, Parkinson C, Unwin PR. Scanning Electrochemical Microscopy as a Quantitative Probe of Acid-Induced Dissolution: Theory and Application to Dental Enamel. Anal Chem 2010; 82:9322-8. [DOI: 10.1021/ac101662h] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
- Carrie-Anne McGeouch
- Electrochemistry and Interfaces Group, Department of Chemistry, University of Warwick, Coventry CV4 7AL, United Kingdom, Molecular Organisation and Assembly in Cells, Doctoral Training Centre, University of Warwick, Coventry CV4 7AL, United Kingdom, and GlaxoSmithKline Consumer Healthcare Research and Development, Surrey KT13 0DE, United Kingdom
| | - Martin A. Edwards
- Electrochemistry and Interfaces Group, Department of Chemistry, University of Warwick, Coventry CV4 7AL, United Kingdom, Molecular Organisation and Assembly in Cells, Doctoral Training Centre, University of Warwick, Coventry CV4 7AL, United Kingdom, and GlaxoSmithKline Consumer Healthcare Research and Development, Surrey KT13 0DE, United Kingdom
| | - Michael M. Mbogoro
- Electrochemistry and Interfaces Group, Department of Chemistry, University of Warwick, Coventry CV4 7AL, United Kingdom, Molecular Organisation and Assembly in Cells, Doctoral Training Centre, University of Warwick, Coventry CV4 7AL, United Kingdom, and GlaxoSmithKline Consumer Healthcare Research and Development, Surrey KT13 0DE, United Kingdom
| | - Charles Parkinson
- Electrochemistry and Interfaces Group, Department of Chemistry, University of Warwick, Coventry CV4 7AL, United Kingdom, Molecular Organisation and Assembly in Cells, Doctoral Training Centre, University of Warwick, Coventry CV4 7AL, United Kingdom, and GlaxoSmithKline Consumer Healthcare Research and Development, Surrey KT13 0DE, United Kingdom
| | - Patrick R. Unwin
- Electrochemistry and Interfaces Group, Department of Chemistry, University of Warwick, Coventry CV4 7AL, United Kingdom, Molecular Organisation and Assembly in Cells, Doctoral Training Centre, University of Warwick, Coventry CV4 7AL, United Kingdom, and GlaxoSmithKline Consumer Healthcare Research and Development, Surrey KT13 0DE, United Kingdom
| |
Collapse
|
46
|
Ebejer N, Schnippering M, Colburn AW, Edwards MA, Unwin PR. Localized High Resolution Electrochemistry and Multifunctional Imaging: Scanning Electrochemical Cell Microscopy. Anal Chem 2010; 82:9141-5. [DOI: 10.1021/ac102191u] [Citation(s) in RCA: 214] [Impact Index Per Article: 15.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Affiliation(s)
- Neil Ebejer
- Department of Chemistry, University of Warwick, Coventry CV4 7AL, United Kingdom
| | - Mathias Schnippering
- Department of Chemistry, University of Warwick, Coventry CV4 7AL, United Kingdom
| | - Alexander W. Colburn
- Department of Chemistry, University of Warwick, Coventry CV4 7AL, United Kingdom
| | - Martin A. Edwards
- Department of Chemistry, University of Warwick, Coventry CV4 7AL, United Kingdom
| | - Patrick R. Unwin
- Department of Chemistry, University of Warwick, Coventry CV4 7AL, United Kingdom
| |
Collapse
|
47
|
Powell HV, Schnippering M, Cheung M, Macpherson JV, Mackenzie SR, Stavros VG, Unwin PR. Probing Redox Reactions of Immobilized Cytochrome c Using Evanescent Wave Cavity Ring-Down Spectroscopy in a Thin-Layer Electrochemical Cell. Chemphyschem 2010; 11:2985-91. [DOI: 10.1002/cphc.201000213] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
48
|
Combining electrochemistry and direct force measurements: from the control of surface properties towards applications. Colloid Polym Sci 2010. [DOI: 10.1007/s00396-010-2260-4] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
49
|
Schulte A, Nebel M, Schuhmann W. Scanning electrochemical microscopy in neuroscience. ANNUAL REVIEW OF ANALYTICAL CHEMISTRY (PALO ALTO, CALIF.) 2010; 3:299-318. [PMID: 20636044 DOI: 10.1146/annurev.anchem.111808.073651] [Citation(s) in RCA: 45] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/29/2023]
Abstract
This article reviews recent work involving the application of scanning electrochemical microscopy (SECM) to the study of individual cultured living cells, with an emphasis on topographical and functional imaging of neuronal and secretory cells of the nervous and endocrine system. The basic principles of biological SECM and associated negative amperometric-feedback and generator/collector-mode SECM imaging are discussed, and successful use of the methodology for screening soft and fragile membranous objects is outlined. The drawbacks of the constant-height mode of probe movement and the benefits of the constant-distance mode of SECM operation are described. Finally, representative examples of constant-height and constant-distance mode SECM on a variety of live cells are highlighted to demonstrate the current status of single-cell SECM in general and of SECM in neuroscience in particular.
Collapse
Affiliation(s)
- Albert Schulte
- Institute of Science, Suranaree University of Technology, Nakhon Ratchasima, Thailand.
| | | | | |
Collapse
|
50
|
New oxygen evolution anodes for metal electrowinning: investigation of local physicochemical processes on composite electrodes with conductive atomic force microscopy and scanning electrochemical microscopy. J APPL ELECTROCHEM 2009. [DOI: 10.1007/s10800-009-0033-x] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|