1
|
Carnicer-Lombarte A, Boys AJ, Güemes A, Gurke J, Velasco-Bosom S, Hilton S, Barone DG, Malliaras GG. Ultraconformable cuff implants for long-term bidirectional interfacing of peripheral nerves at sub-nerve resolutions. Nat Commun 2024; 15:7523. [PMID: 39214981 PMCID: PMC11364531 DOI: 10.1038/s41467-024-51988-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2024] [Accepted: 08/21/2024] [Indexed: 09/04/2024] Open
Abstract
Implantable devices interfacing with peripheral nerves exhibit limited longevity and resolution. Poor nerve-electrode interface quality, invasive surgical placement and development of foreign body reaction combine to limit research and clinical application of these devices. Here, we develop cuff implants with a conformable design that achieve high-quality and stable interfacing with nerves in chronic implantation scenarios. When implanted in sensorimotor nerves of the arm in awake rats for 21 days, the devices record nerve action potentials with fascicle-specific resolution and extract from these the conduction velocity and direction of propagation. The cuffs exhibit high biocompatibility, producing lower levels of fibrotic scarring than clinically equivalent PDMS silicone cuffs. In addition to recording nerve activity, the devices are able to modulate nerve activity at sub-nerve resolution to produce a wide range of paw movements. When used in a partial nerve ligation rodent model, the cuffs identify and characterise changes in nerve C fibre activity associated with the development of neuropathic pain in freely-moving animals. The developed implantable devices represent a platform enabling new forms of fine nerve signal sensing and modulation, with applications in physiology research and closed-loop therapeutics.
Collapse
Affiliation(s)
- Alejandro Carnicer-Lombarte
- University of Cambridge, Electrical Engineering Division, 9 JJ Thomson Ave, Cambridge, CB3 0FA, United Kingdom
| | - Alexander J Boys
- University of Cambridge, Department of Chemical Engineering and Biotechnology, Cambridge, CB2 0QQ, United Kingdom
| | - Amparo Güemes
- University of Cambridge, Electrical Engineering Division, 9 JJ Thomson Ave, Cambridge, CB3 0FA, United Kingdom
| | - Johannes Gurke
- University of Cambridge, Electrical Engineering Division, 9 JJ Thomson Ave, Cambridge, CB3 0FA, United Kingdom
- University of Potsdam, Institute of Chemistry, Karl-Liebknecht-Str. 24-25, 14476, Potsdam, Germany
| | - Santiago Velasco-Bosom
- University of Cambridge, Electrical Engineering Division, 9 JJ Thomson Ave, Cambridge, CB3 0FA, United Kingdom
| | - Sam Hilton
- University of Cambridge, Electrical Engineering Division, 9 JJ Thomson Ave, Cambridge, CB3 0FA, United Kingdom
| | - Damiano G Barone
- University of Cambridge, Electrical Engineering Division, 9 JJ Thomson Ave, Cambridge, CB3 0FA, United Kingdom.
- University of Cambridge, School of Clinical Medicine, Department of Clinical Neurosciences, Cambridge Biomedical Campus, Cambridge, CB2 0QQ, United Kingdom.
| | - George G Malliaras
- University of Cambridge, Electrical Engineering Division, 9 JJ Thomson Ave, Cambridge, CB3 0FA, United Kingdom.
| |
Collapse
|
2
|
Zhang B, Hu Y, Du H, Han S, Ren L, Cheng H, Wang Y, Gao X, Zheng S, Cui Q, Tian L, Liu T, Sun J, Chai R. Tissue engineering strategies for spiral ganglion neuron protection and regeneration. J Nanobiotechnology 2024; 22:458. [PMID: 39085923 PMCID: PMC11293049 DOI: 10.1186/s12951-024-02742-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2024] [Accepted: 07/25/2024] [Indexed: 08/02/2024] Open
Abstract
Cochlear implants can directly activate the auditory system's primary sensory neurons, the spiral ganglion neurons (SGNs), via circumvention of defective cochlear hair cells. This bypass restores auditory input to the brainstem. SGN loss etiologies are complex, with limited mammalian regeneration. Protecting and revitalizing SGN is critical. Tissue engineering offers a novel therapeutic strategy, utilizing seed cells, biomolecules, and scaffold materials to create a cellular environment and regulate molecular cues. This review encapsulates the spectrum of both human and animal research, collating the factors contributing to SGN loss, the latest advancements in the utilization of exogenous stem cells for auditory nerve repair and preservation, the taxonomy and mechanism of action of standard biomolecules, and the architectural components of scaffold materials tailored for the inner ear. Furthermore, we delineate the potential and benefits of the biohybrid neural interface, an incipient technology in the realm of implantable devices. Nonetheless, tissue engineering requires refined cell selection and differentiation protocols for consistent SGN quality. In addition, strategies to improve stem cell survival, scaffold biocompatibility, and molecular cue timing are essential for biohybrid neural interface integration.
Collapse
Affiliation(s)
- Bin Zhang
- State Key Laboratory of Digital Medical Engineering, Department of Otolaryngology Head and Neck Surgery, Zhongda Hospital, School of Public Health, Advanced Institute for Life and Health, Jiangsu Province High-Tech Key Laboratory for Bio-Medical Research, Southeast University, Nanjing, 210096, China
- Co-Innovation Center of Neuroregeneration, Nantong University, Nantong, 226001, China
| | - Yangnan Hu
- State Key Laboratory of Digital Medical Engineering, Department of Otolaryngology Head and Neck Surgery, Zhongda Hospital, School of Public Health, Advanced Institute for Life and Health, Jiangsu Province High-Tech Key Laboratory for Bio-Medical Research, Southeast University, Nanjing, 210096, China.
- Co-Innovation Center of Neuroregeneration, Nantong University, Nantong, 226001, China.
| | - Haoliang Du
- Department of Otolaryngology Head and Neck Surgery, Nanjing Drum Tower Hospital, Affiliated Hospital of Medical School, Jiangsu Provincial Key Medical Discipline (Laboratory), Nanjing University, Nanjing, 210008, China
| | - Shanying Han
- Department of Otolaryngology Head and Neck Surgery, Sichuan Provincial People's Hospital, University of Electronic Science and Technology of China, Chengdu, 610072, China
| | - Lei Ren
- State Key Laboratory of Digital Medical Engineering, Department of Otolaryngology Head and Neck Surgery, Zhongda Hospital, School of Public Health, Advanced Institute for Life and Health, Jiangsu Province High-Tech Key Laboratory for Bio-Medical Research, Southeast University, Nanjing, 210096, China
| | - Hong Cheng
- State Key Laboratory of Digital Medical Engineering, Department of Otolaryngology Head and Neck Surgery, Zhongda Hospital, School of Public Health, Advanced Institute for Life and Health, Jiangsu Province High-Tech Key Laboratory for Bio-Medical Research, Southeast University, Nanjing, 210096, China
| | - Yusong Wang
- State Key Laboratory of Digital Medical Engineering, Department of Otolaryngology Head and Neck Surgery, Zhongda Hospital, School of Public Health, Advanced Institute for Life and Health, Jiangsu Province High-Tech Key Laboratory for Bio-Medical Research, Southeast University, Nanjing, 210096, China
| | - Xin Gao
- State Key Laboratory of Digital Medical Engineering, Department of Otolaryngology Head and Neck Surgery, Zhongda Hospital, School of Public Health, Advanced Institute for Life and Health, Jiangsu Province High-Tech Key Laboratory for Bio-Medical Research, Southeast University, Nanjing, 210096, China
| | - Shasha Zheng
- State Key Laboratory of Digital Medical Engineering, Department of Otolaryngology Head and Neck Surgery, Zhongda Hospital, School of Public Health, Advanced Institute for Life and Health, Jiangsu Province High-Tech Key Laboratory for Bio-Medical Research, Southeast University, Nanjing, 210096, China
| | - Qingyue Cui
- State Key Laboratory of Digital Medical Engineering, Department of Otolaryngology Head and Neck Surgery, Zhongda Hospital, School of Public Health, Advanced Institute for Life and Health, Jiangsu Province High-Tech Key Laboratory for Bio-Medical Research, Southeast University, Nanjing, 210096, China
| | - Lei Tian
- State Key Laboratory of Digital Medical Engineering, Department of Otolaryngology Head and Neck Surgery, Zhongda Hospital, School of Public Health, Advanced Institute for Life and Health, Jiangsu Province High-Tech Key Laboratory for Bio-Medical Research, Southeast University, Nanjing, 210096, China.
| | - Tingting Liu
- State Key Laboratory of Digital Medical Engineering, Department of Otolaryngology Head and Neck Surgery, Zhongda Hospital, School of Public Health, Advanced Institute for Life and Health, Jiangsu Province High-Tech Key Laboratory for Bio-Medical Research, Southeast University, Nanjing, 210096, China.
| | - Jiaqiang Sun
- Department of Otolaryngology-Head and Neck Surgery, Division of Life Sciences and Medicine, The First Affiliated Hospital of USTC, University of Science and Technology of China, Hefei, Anhui, 230001, China.
| | - Renjie Chai
- State Key Laboratory of Digital Medical Engineering, Department of Otolaryngology Head and Neck Surgery, Zhongda Hospital, School of Public Health, Advanced Institute for Life and Health, Jiangsu Province High-Tech Key Laboratory for Bio-Medical Research, Southeast University, Nanjing, 210096, China.
- Co-Innovation Center of Neuroregeneration, Nantong University, Nantong, 226001, China.
- Department of Otolaryngology Head and Neck Surgery, Sichuan Provincial People's Hospital, University of Electronic Science and Technology of China, Chengdu, 610072, China.
- Department of Neurology, Aerospace Center Hospital, School of Life Science, Beijing Institute of Technology, Beijing, 100081, China.
- Institute for Stem Cell and Regeneration, Chinese Academy of Science, Beijing, China.
- Southeast University Shenzhen Research Institute, Shenzhen, 518063, China.
| |
Collapse
|
3
|
Blau R, Russman SM, Qie Y, Shipley W, Lim A, Chen AX, Nyayachavadi A, Ah L, Abdal A, Esparza GL, Edmunds SJ, Vatsyayan R, Dunfield SP, Halder M, Jokerst JV, Fenning DP, Tao AR, Dayeh SA, Lipomi DJ. Surface-Grafted Biocompatible Polymer Conductors for Stable and Compliant Electrodes for Brain Interfaces. Adv Healthc Mater 2024:e2402215. [PMID: 39011811 DOI: 10.1002/adhm.202402215] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2024] [Revised: 07/02/2024] [Indexed: 07/17/2024]
Abstract
Durable and conductive interfaces that enable chronic and high-resolution recording of neural activity are essential for understanding and treating neurodegenerative disorders. These chronic implants require long-term stability and small contact areas. Consequently, they are often coated with a blend of conductive polymers and are crosslinked to enhance durability despite the potentially deleterious effect of crosslinking on the mechanical and electrical properties. Here the grafting of the poly(3,4 ethylenedioxythiophene) scaffold, poly(styrenesulfonate)-b-poly(poly(ethylene glycol) methyl ether methacrylate block copolymer brush to gold, in a controlled and tunable manner, by surface-initiated atom-transfer radical polymerization (SI-ATRP) is described. This "block-brush" provides high volumetric capacitance (120 F cm─3), strong adhesion to the metal (4 h ultrasonication), improved surface hydrophilicity, and stability against 10 000 charge-discharge voltage sweeps on a multiarray neural electrode. In addition, the block-brush film showed 33% improved stability against current pulsing. This approach can open numerous avenues for exploring specialized polymer brushes for bioelectronics research and application.
Collapse
Affiliation(s)
- Rachel Blau
- Aiiso Yufeng Li Family Department of Chemical and Nano Engineering, University of California, San Diego, 9500 Gilman Drive, La Jolla, CA, 92093-0448, USA
| | - Samantha M Russman
- Department of Bioengineering, University of California, San Diego, 9500 Gilman Drive, La Jolla, CA, 92093-0448, USA
| | - Yi Qie
- Aiiso Yufeng Li Family Department of Chemical and Nano Engineering, University of California, San Diego, 9500 Gilman Drive, La Jolla, CA, 92093-0448, USA
| | - Wade Shipley
- Materials Science and Engineering Program, University of California, San Diego, 9500 Gilman Drive, La Jolla, CA, 92093-0418, USA
| | - Allison Lim
- Aiiso Yufeng Li Family Department of Chemical and Nano Engineering, University of California, San Diego, 9500 Gilman Drive, La Jolla, CA, 92093-0448, USA
| | - Alexander X Chen
- Aiiso Yufeng Li Family Department of Chemical and Nano Engineering, University of California, San Diego, 9500 Gilman Drive, La Jolla, CA, 92093-0448, USA
| | - Audithya Nyayachavadi
- Aiiso Yufeng Li Family Department of Chemical and Nano Engineering, University of California, San Diego, 9500 Gilman Drive, La Jolla, CA, 92093-0448, USA
| | - Louis Ah
- Aiiso Yufeng Li Family Department of Chemical and Nano Engineering, University of California, San Diego, 9500 Gilman Drive, La Jolla, CA, 92093-0448, USA
| | - Abdulhameed Abdal
- Department of Mechanical and Aerospace Engineering, University of California, San Diego, 9500 Gilman Drive, La Jolla, CA, 92093-0448, USA
| | - Guillermo L Esparza
- Aiiso Yufeng Li Family Department of Chemical and Nano Engineering, University of California, San Diego, 9500 Gilman Drive, La Jolla, CA, 92093-0448, USA
| | - Samuel J Edmunds
- Department of Electrical and Computer Engineering, University of California, San Diego, 9500 Gilman Drive, La Jolla, CA, 92093-0448, USA
| | - Ritwik Vatsyayan
- Department of Electrical and Computer Engineering, University of California, San Diego, 9500 Gilman Drive, La Jolla, CA, 92093-0448, USA
| | - Sean P Dunfield
- Aiiso Yufeng Li Family Department of Chemical and Nano Engineering, University of California, San Diego, 9500 Gilman Drive, La Jolla, CA, 92093-0448, USA
| | - Moumita Halder
- Aiiso Yufeng Li Family Department of Chemical and Nano Engineering, University of California, San Diego, 9500 Gilman Drive, La Jolla, CA, 92093-0448, USA
| | - Jesse V Jokerst
- Aiiso Yufeng Li Family Department of Chemical and Nano Engineering, University of California, San Diego, 9500 Gilman Drive, La Jolla, CA, 92093-0448, USA
| | - David P Fenning
- Aiiso Yufeng Li Family Department of Chemical and Nano Engineering, University of California, San Diego, 9500 Gilman Drive, La Jolla, CA, 92093-0448, USA
| | - Andrea R Tao
- Aiiso Yufeng Li Family Department of Chemical and Nano Engineering, University of California, San Diego, 9500 Gilman Drive, La Jolla, CA, 92093-0448, USA
- Materials Science and Engineering Program, University of California, San Diego, 9500 Gilman Drive, La Jolla, CA, 92093-0418, USA
| | - Shadi A Dayeh
- Department of Bioengineering, University of California, San Diego, 9500 Gilman Drive, La Jolla, CA, 92093-0448, USA
- Department of Electrical and Computer Engineering, University of California, San Diego, 9500 Gilman Drive, La Jolla, CA, 92093-0448, USA
| | - Darren J Lipomi
- Aiiso Yufeng Li Family Department of Chemical and Nano Engineering, University of California, San Diego, 9500 Gilman Drive, La Jolla, CA, 92093-0448, USA
| |
Collapse
|
4
|
Zhou C, Tian Y, Li G, Ye Y, Gao L, Li J, Liu Z, Su H, Lu Y, Li M, Zhou Z, Wei X, Qin L, Tao TH, Sun L. Through-polymer, via technology-enabled, flexible, lightweight, and integrated devices for implantable neural probes. MICROSYSTEMS & NANOENGINEERING 2024; 10:54. [PMID: 38654844 PMCID: PMC11035623 DOI: 10.1038/s41378-024-00691-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/28/2023] [Revised: 02/29/2024] [Accepted: 03/11/2024] [Indexed: 04/26/2024]
Abstract
In implantable electrophysiological recording systems, the headstage typically comprises neural probes that interface with brain tissue and integrated circuit chips for signal processing. While advancements in MEMS and CMOS technology have significantly improved these components, their interconnection still relies on conventional printed circuit boards and sophisticated adapters. This conventional approach adds considerable weight and volume to the package, especially for high channel count systems. To address this issue, we developed a through-polymer via (TPV) method inspired by the through-silicon via (TSV) technique in advanced three-dimensional packaging. This innovation enables the vertical integration of flexible probes, amplifier chips, and PCBs, realizing a flexible, lightweight, and integrated device (FLID). The total weight of the FLIDis only 25% that of its conventional counterparts relying on adapters, which significantly increased the activity levels of animals wearing the FLIDs to nearly match the levels of control animals without implants. Furthermore, by incorporating a platinum-iridium alloy as the top layer material for electrical contact, the FLID realizes exceptional electrical performance, enabling in vivo measurements of both local field potentials and individual neuron action potentials. These findings showcase the potential of FLIDs in scaling up implantable neural recording systems and mark a significant advancement in the field of neurotechnology.
Collapse
Grants
- This work was partially supported by the National Key R & D Program of China (Grant Nos. 2021ZD0201600, 2022YFF0706504, 2022ZD0209300, 2019YFA0905200, 2021YFC2501500, 2021YFF1200700, 2022ZD0212300), National Natural Science Foundation of China (Grant No. 61974154), Key Research Program of Frontier Sciences, CAS (Grant No. ZDBS-LY-JSC024), Shanghai Pilot Program for Basic Research-Chinese Academy of Science, Shanghai Branch (Grant No. JCYJ-SHFY-2022-01 and JCYJ-SHFY-2022-0xx), Shanghai Municipal Science and Technology Major Project (Grant No. 2021SHZDZX), CAS Pioneer Hundred Talents Program, Shanghai Pujiang Program (Grant Nos. 21PJ1415100, 19PJ1410900), the Science and Technology Commission Foundation of Shanghai (Nos. 21JM0010200 and 21142200300), Shanghai Rising-Star Program (Grant No. 22QA1410900), Shanghai Sailing Program (No. 22YF1454700), the Innovative Research Team of High-level Local Universities in Shanghai, the Jiangxi Province 03 Special Project and 5G Project (Grant No. 20212ABC03W07), Fund for Central Government in Guidance of Local Science and Technology Development (Grant No. 20201ZDE04013), Special Fund for Science and Technology Innovation Strategy of Guangdong Province (Grant Nos. 2021B0909060002, 2021B0909050004).
Collapse
Affiliation(s)
- Cunkai Zhou
- College of Electronics and Information Engineering, Shanghai University of Electric Power, Shanghai, China
- 2020 X-Lab, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, China
| | - Ye Tian
- 2020 X-Lab, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, China
- School of Graduate Study, University of Chinese Academy of Sciences, Beijing, China
| | - Gen Li
- 2020 X-Lab, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, China
- School of Graduate Study, University of Chinese Academy of Sciences, Beijing, China
| | - Yifei Ye
- 2020 X-Lab, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, China
| | - Lusha Gao
- 2020 X-Lab, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, China
| | - Jiazhi Li
- 2020 X-Lab, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, China
| | - Ziwei Liu
- 2020 X-Lab, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, China
| | - Haoyang Su
- School of Graduate Study, University of Chinese Academy of Sciences, Beijing, China
- State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, China
| | - Yunxiao Lu
- College of Electronics and Information Engineering, Shanghai University of Electric Power, Shanghai, China
- 2020 X-Lab, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, China
| | - Meng Li
- School of Graduate Study, University of Chinese Academy of Sciences, Beijing, China
- State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, China
| | - Zhitao Zhou
- School of Graduate Study, University of Chinese Academy of Sciences, Beijing, China
- State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, China
| | - Xiaoling Wei
- School of Graduate Study, University of Chinese Academy of Sciences, Beijing, China
- State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, China
| | - Lunming Qin
- College of Electronics and Information Engineering, Shanghai University of Electric Power, Shanghai, China
| | - Tiger H. Tao
- 2020 X-Lab, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, China
- School of Graduate Study, University of Chinese Academy of Sciences, Beijing, China
- State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, China
- Center of Materials Science and Optoelectronics Engineering, University of Chinese Academy of Sciences, Beijing, China
- School of Physical Science and Technology, ShanghaiTech University, Shanghai, China
- Center for Excellence in Brain Science and Intelligence Technology, Chinese Academy of Sciences, Shanghai, China
- Neuroxess Co., Ltd. (Jiangxi), Nanchang, Jiangxi China
- Guangdong Institute of Intelligence Science and Technology, Hengqin, Zhuhai, Guangdong China
- Tianqiao and Chrissy Chen Institute for Translational Research, Shanghai, China
| | - Liuyang Sun
- College of Electronics and Information Engineering, Shanghai University of Electric Power, Shanghai, China
- 2020 X-Lab, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, China
- School of Graduate Study, University of Chinese Academy of Sciences, Beijing, China
- State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, China
| |
Collapse
|
5
|
Han J, Choi J, Jeong H, Park D, Cheong E, Sung J, Choi HJ. Impact of Impedance Levels on Recording Quality in Flexible Neural Probes. SENSORS (BASEL, SWITZERLAND) 2024; 24:2300. [PMID: 38610511 PMCID: PMC11014004 DOI: 10.3390/s24072300] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/12/2024] [Revised: 04/01/2024] [Accepted: 04/03/2024] [Indexed: 04/14/2024]
Abstract
Flexible neural probes are attractive emerging technologies for brain recording because they can effectively record signals with minimal risk of brain damage. Reducing the electrode impedance of the probe before recording is a common practice of many researchers. However, studies investigating the impact of low impedance levels on high-quality recordings using flexible neural probes are lacking. In this study, we electrodeposited Pt onto a commercial flexible polyimide neural probe and investigated the relationship between the impedance level and the recording quality. The probe was inserted into the brains of anesthetized mice. The electrical signals of neurons in the brain, specifically the ventral posteromedial nucleus of the thalamus, were recorded at impedance levels of 50, 250, 500 and 1000 kΩ at 1 kHz. The study results demonstrated that as the impedance decreased, the quality of the signal recordings did not consistently improve. This suggests that extreme lowering of the impedance may not always be advantageous in the context of flexible neural probes.
Collapse
Affiliation(s)
- Juyeon Han
- Department of Materials Science and Engineering, Yonsei University, Seoul 03722, Republic of Korea; (J.H.)
| | - Jungsik Choi
- Department of Materials Science and Engineering, Yonsei University, Seoul 03722, Republic of Korea; (J.H.)
- Nformare Inc., Seodamun-gu, Seoul 03722, Republic of Korea
| | - Hyeonyeong Jeong
- Department of Biotechnology, Yonsei University, Seoul 03722, Republic of Korea
| | - Daerl Park
- Department of Materials Science and Engineering, Yonsei University, Seoul 03722, Republic of Korea; (J.H.)
| | - Eunji Cheong
- Department of Biotechnology, Yonsei University, Seoul 03722, Republic of Korea
| | - Jaesuk Sung
- Nformare Inc., Seodamun-gu, Seoul 03722, Republic of Korea
| | - Heon-Jin Choi
- Department of Materials Science and Engineering, Yonsei University, Seoul 03722, Republic of Korea; (J.H.)
- Nformare Inc., Seodamun-gu, Seoul 03722, Republic of Korea
| |
Collapse
|
6
|
Bhatia A, Hanna J, Stuart T, Kasper KA, Clausen DM, Gutruf P. Wireless Battery-free and Fully Implantable Organ Interfaces. Chem Rev 2024; 124:2205-2280. [PMID: 38382030 DOI: 10.1021/acs.chemrev.3c00425] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/23/2024]
Abstract
Advances in soft materials, miniaturized electronics, sensors, stimulators, radios, and battery-free power supplies are resulting in a new generation of fully implantable organ interfaces that leverage volumetric reduction and soft mechanics by eliminating electrochemical power storage. This device class offers the ability to provide high-fidelity readouts of physiological processes, enables stimulation, and allows control over organs to realize new therapeutic and diagnostic paradigms. Driven by seamless integration with connected infrastructure, these devices enable personalized digital medicine. Key to advances are carefully designed material, electrophysical, electrochemical, and electromagnetic systems that form implantables with mechanical properties closely matched to the target organ to deliver functionality that supports high-fidelity sensors and stimulators. The elimination of electrochemical power supplies enables control over device operation, anywhere from acute, to lifetimes matching the target subject with physical dimensions that supports imperceptible operation. This review provides a comprehensive overview of the basic building blocks of battery-free organ interfaces and related topics such as implantation, delivery, sterilization, and user acceptance. State of the art examples categorized by organ system and an outlook of interconnection and advanced strategies for computation leveraging the consistent power influx to elevate functionality of this device class over current battery-powered strategies is highlighted.
Collapse
Affiliation(s)
- Aman Bhatia
- Department of Biomedical Engineering, The University of Arizona, Tucson, Arizona 85721, United States
| | - Jessica Hanna
- Department of Biomedical Engineering, The University of Arizona, Tucson, Arizona 85721, United States
| | - Tucker Stuart
- Department of Biomedical Engineering, The University of Arizona, Tucson, Arizona 85721, United States
| | - Kevin Albert Kasper
- Department of Biomedical Engineering, The University of Arizona, Tucson, Arizona 85721, United States
| | - David Marshall Clausen
- Department of Biomedical Engineering, The University of Arizona, Tucson, Arizona 85721, United States
| | - Philipp Gutruf
- Department of Biomedical Engineering, The University of Arizona, Tucson, Arizona 85721, United States
- Department of Electrical and Computer Engineering, The University of Arizona, Tucson, Arizona 85721, United States
- Bio5 Institute, The University of Arizona, Tucson, Arizona 85721, United States
- Neuroscience Graduate Interdisciplinary Program (GIDP), The University of Arizona, Tucson, Arizona 85721, United States
| |
Collapse
|
7
|
Cho M, Han JK, Suh J, Kim JJ, Ryu JR, Min IS, Sang M, Lim S, Kim TS, Kim K, Kang K, Hwang K, Kim K, Hong EB, Nam MH, Kim J, Song YM, Lee GJ, Cho IJ, Yu KJ. Fully bioresorbable hybrid opto-electronic neural implant system for simultaneous electrophysiological recording and optogenetic stimulation. Nat Commun 2024; 15:2000. [PMID: 38448437 PMCID: PMC10917781 DOI: 10.1038/s41467-024-45803-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2023] [Accepted: 02/05/2024] [Indexed: 03/08/2024] Open
Abstract
Bioresorbable neural implants based on emerging classes of biodegradable materials offer a promising solution to the challenges of secondary surgeries for removal of implanted devices required for existing neural implants. In this study, we introduce a fully bioresorbable flexible hybrid opto-electronic system for simultaneous electrophysiological recording and optogenetic stimulation. The flexible and soft device, composed of biodegradable materials, has a direct optical and electrical interface with the curved cerebral cortex surface while exhibiting excellent biocompatibility. Optimized to minimize light transmission losses and photoelectric artifact interference, the device was chronically implanted in the brain of transgenic mice and performed to photo-stimulate the somatosensory area while recording local field potentials. Thus, the presented hybrid neural implant system, comprising biodegradable materials, promises to provide monitoring and therapy modalities for versatile applications in biomedicine.
Collapse
Affiliation(s)
- Myeongki Cho
- Functional Bio-integrated Electronics and Energy Management Lab, School of Electrical and Electronic Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea
| | - Jeong-Kyu Han
- Brain Science Institute, Korea Institute of Science and Technology, 5. Hwarang-ro 14-gil, Seongbuk-gu, Seoul, 02792, Republic of Korea
| | - Jungmin Suh
- Functional Bio-integrated Electronics and Energy Management Lab, School of Electrical and Electronic Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea
| | - Jeong Jin Kim
- Department of Electronics Engineering, Pusan National University, 2, Busandaehak-ro 63beon-gil, Geumjeong-gu, Busan, 46241, Republic of Korea
| | - Jae Ryun Ryu
- Department of Anatomy, College of Medicine, Korea University, 17-gil Koryodae-ro, Seongbuk-gu, Seoul, 02841, Republic of Korea
| | - In Sik Min
- Functional Bio-integrated Electronics and Energy Management Lab, School of Electrical and Electronic Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea
| | - Mingyu Sang
- Functional Bio-integrated Electronics and Energy Management Lab, School of Electrical and Electronic Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea
| | - Selin Lim
- Functional Bio-integrated Electronics and Energy Management Lab, School of Electrical and Electronic Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea
| | - Tae Soo Kim
- Functional Bio-integrated Electronics and Energy Management Lab, School of Electrical and Electronic Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea
| | - Kyubeen Kim
- Functional Bio-integrated Electronics and Energy Management Lab, School of Electrical and Electronic Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea
| | - Kyowon Kang
- Functional Bio-integrated Electronics and Energy Management Lab, School of Electrical and Electronic Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea
| | - Kyuhyun Hwang
- School of Mechanical Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea
| | - Kanghwan Kim
- Brain Science Institute, Korea Institute of Science and Technology, 5. Hwarang-ro 14-gil, Seongbuk-gu, Seoul, 02792, Republic of Korea
| | - Eun-Bin Hong
- Center for Brain Function, Korea Institute of Science and Technology 5, Hwarang-ro 14-gil, Seongbuk-gu, Seoul, 02792, Republic of Korea
| | - Min-Ho Nam
- Center for Brain Function, Korea Institute of Science and Technology 5, Hwarang-ro 14-gil, Seongbuk-gu, Seoul, 02792, Republic of Korea
| | - Jongbaeg Kim
- School of Mechanical Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea
| | - Young Min Song
- School of Electrical Engineering and Computer Science (EECS), Gwangju Institute of Science and Technology (GIST), Gwangju, 61005, Republic of Korea
| | - Gil Ju Lee
- Department of Electronics Engineering, Pusan National University, 2, Busandaehak-ro 63beon-gil, Geumjeong-gu, Busan, 46241, Republic of Korea.
| | - Il-Joo Cho
- Department of Convergence Medicine, College of Medicine, Korea University, 17-gil Koryodae-ro, Seongbuk-gu, Seoul, 02841, Republic of Korea.
- Department of Anatomy, College of Medicine, Korea University, 7-gil Koryodae-ro, Seongbuk-gu, Seoul, 02841, Republic of Korea.
| | - Ki Jun Yu
- Functional Bio-integrated Electronics and Energy Management Lab, School of Electrical and Electronic Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea.
- Department of Electrical and Electronic Engineering, YU-Korea Institute of Science and Technology (KIST) Institute, Yonsei University, 50, Yonsei-ro, Seodaemun-gu, Seoul, 03722, Korea.
| |
Collapse
|
8
|
Scholten K, Xu H, Lu Z, Jiang W, Ortigoza-Diaz J, Petrossians A, Orler S, Gallonio R, Liu X, Song D, Meng E. Polymer Implantable Electrode Foundry: A shared resource for manufacturing polymer-based microelectrodes for neural interfaces. BIORXIV : THE PREPRINT SERVER FOR BIOLOGY 2023:2023.11.05.565048. [PMID: 37986740 PMCID: PMC10659271 DOI: 10.1101/2023.11.05.565048] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/22/2023]
Abstract
Large scale monitoring of neural activity at the single unit level can be achieved via electrophysiological recording using implanted microelectrodes. While neuroscience researchers have widely employed chronically implanted electrode-based interfaces for this purpose, a commonly encountered limitation is loss of highly resolved signals arising from immunological response over time. Next generation electrode-based interfaces improve longitudinal signal quality using the strategy of stabilizing the device-tissue interface with microelectrode arrays constructed from soft and flexible polymer materials. The limited availability of such polymer microelectrode arrays has restricted access to a small number of researchers able to build their own custom devices or who have developed specific collaborations with engineering researchers who can produce them. Here, a new technology resource model is introduced that seeks to widely increase access to polymer microelectrode arrays by the neuroscience research community. The Polymer Implantable Electrode (PIE) Foundry provides custom and standardized polymer microelectrode arrays as well as training and guidance on best-practices for implantation and chronic experiments.
Collapse
Affiliation(s)
- Kee Scholten
- Alfred E. Mann Department of Biomedical Engineering, University of Southern California, Los Angeles, USA
| | - Huijing Xu
- Alfred E. Mann Department of Biomedical Engineering, University of Southern California, Los Angeles, USA
| | - Zhouxiao Lu
- Alfred E. Mann Department of Biomedical Engineering, University of Southern California, Los Angeles, USA
| | - Wenxuan Jiang
- Alfred E. Mann Department of Biomedical Engineering, University of Southern California, Los Angeles, USA
| | - Jessica Ortigoza-Diaz
- Alfred E. Mann Department of Biomedical Engineering, University of Southern California, Los Angeles, USA
| | - Artin Petrossians
- Alfred E. Mann Department of Biomedical Engineering, University of Southern California, Los Angeles, USA
| | - Steven Orler
- Alfred E. Mann Department of Biomedical Engineering, University of Southern California, Los Angeles, USA
| | - Rachael Gallonio
- Alfred E. Mann Department of Biomedical Engineering, University of Southern California, Los Angeles, USA
| | - Xin Liu
- Alfred E. Mann Department of Biomedical Engineering, University of Southern California, Los Angeles, USA
| | - Dong Song
- Alfred E. Mann Department of Biomedical Engineering, University of Southern California, Los Angeles, USA
- Neuroscience Graduate Program, University of Southern California, Los Angeles, USA
| | - Ellis Meng
- Alfred E. Mann Department of Biomedical Engineering, University of Southern California, Los Angeles, USA
- Ming Hsieh Department of Electrical and Computer Engineering, University of Southern California, Los Angeles, USA
| |
Collapse
|
9
|
Ji B, Sun F, Guo J, Zhou Y, You X, Fan Y, Wang L, Xu M, Zeng W, Liu J, Wang M, Hu H, Chang H. Brainmask: an ultrasoft and moist micro-electrocorticography electrode for accurate positioning and long-lasting recordings. MICROSYSTEMS & NANOENGINEERING 2023; 9:126. [PMID: 37829160 PMCID: PMC10564857 DOI: 10.1038/s41378-023-00597-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/15/2023] [Revised: 08/11/2023] [Accepted: 09/02/2023] [Indexed: 10/14/2023]
Abstract
Bacterial cellulose (BC), a natural biomaterial synthesized by bacteria, has a unique structure of a cellulose nanofiber-weaved three-dimensional reticulated network. BC films can be ultrasoft with sufficient mechanical strength, strong water absorption and moisture retention and have been widely used in facial masks. These films have the potential to be applied to implantable neural interfaces due to their conformality and moisture, which are two critical issues for traditional polymer or silicone electrodes. In this work, we propose a micro-electrocorticography (micro-ECoG) electrode named "Brainmask", which comprises a BC film as the substrate and separated multichannel parylene-C microelectrodes bonded on the top surface. Brainmask can not only guarantee the precise position of microelectrode sites attached to any nonplanar epidural surface but also improve the long-lasting signal quality during acute implantation with an exposed cranial window for at least one hour, as well as the in vivo recording validated for one week. This novel ultrasoft and moist device stands as a next-generation neural interface regardless of complex surface or time of duration.
Collapse
Affiliation(s)
- Bowen Ji
- Unmanned System Research Institute, Northwestern Polytechnical University, Xi’an, 710072 China
- Ministry of Education Key Laboratory of Micro and Nano Systems for Aerospace, School of Mechanical Engineering, Northwestern Polytechnical University, Xi’an, 710072 China
- Collaborative Innovation Center of Northwestern Polytechnical University, Shanghai, 201108 China
| | - Fanqi Sun
- Unmanned System Research Institute, Northwestern Polytechnical University, Xi’an, 710072 China
- Ministry of Education Key Laboratory of Micro and Nano Systems for Aerospace, School of Mechanical Engineering, Northwestern Polytechnical University, Xi’an, 710072 China
- Collaborative Innovation Center of Northwestern Polytechnical University, Shanghai, 201108 China
| | - Jiecheng Guo
- Institute of Medical Research, Northwestern Polytechnical University, Xi’an, 710072 China
| | - Yuhao Zhou
- Unmanned System Research Institute, Northwestern Polytechnical University, Xi’an, 710072 China
- Ministry of Education Key Laboratory of Micro and Nano Systems for Aerospace, School of Mechanical Engineering, Northwestern Polytechnical University, Xi’an, 710072 China
- Collaborative Innovation Center of Northwestern Polytechnical University, Shanghai, 201108 China
| | - Xiaoli You
- Unmanned System Research Institute, Northwestern Polytechnical University, Xi’an, 710072 China
- Ministry of Education Key Laboratory of Micro and Nano Systems for Aerospace, School of Mechanical Engineering, Northwestern Polytechnical University, Xi’an, 710072 China
- Collaborative Innovation Center of Northwestern Polytechnical University, Shanghai, 201108 China
| | - Ye Fan
- College of Electronics and Information, Hangzhou Dianzi University, Hangzhou, 310018 China
| | - Longchun Wang
- National Key Laboratory of Science and Technology on Micro/Nano Fabrication, Department of Micro/Nano Electronics, Shanghai Jiao Tong University, Shanghai, 200240 China
| | - Mengfei Xu
- National Key Laboratory of Science and Technology on Micro/Nano Fabrication, Department of Micro/Nano Electronics, Shanghai Jiao Tong University, Shanghai, 200240 China
| | - Wen Zeng
- Ministry of Education Key Laboratory of Micro and Nano Systems for Aerospace, School of Mechanical Engineering, Northwestern Polytechnical University, Xi’an, 710072 China
| | - Jingquan Liu
- National Key Laboratory of Science and Technology on Micro/Nano Fabrication, Department of Micro/Nano Electronics, Shanghai Jiao Tong University, Shanghai, 200240 China
| | - Minghao Wang
- College of Electronics and Information, Hangzhou Dianzi University, Hangzhou, 310018 China
| | - Huijing Hu
- Institute of Medical Research, Northwestern Polytechnical University, Xi’an, 710072 China
| | - Honglong Chang
- Ministry of Education Key Laboratory of Micro and Nano Systems for Aerospace, School of Mechanical Engineering, Northwestern Polytechnical University, Xi’an, 710072 China
| |
Collapse
|
10
|
Xue Y, Chen X, Wang F, Lin J, Liu J. Mechanically-Compliant Bioelectronic Interfaces through Fatigue-Resistant Conducting Polymer Hydrogel Coating. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2023; 35:e2304095. [PMID: 37381603 DOI: 10.1002/adma.202304095] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/02/2023] [Revised: 06/26/2023] [Indexed: 06/30/2023]
Abstract
Because of their distinct electrochemical and mechanical properties, conducting polymer hydrogels have been widely exploited as soft, wet, and conducting coatings for conventional metallic electrodes, providing mechanically compliant interfaces and mitigating foreign body responses. However, the long-term viability of these hydrogel coatings is hindered by concerns regarding fatigue crack propagation and/or delamination caused by repetitive volumetric expansion/shrinkage during long-term electrical interfacing. This study reports a general yet reliable approach to achieving a fatigue-resistant conducting polymer hydrogel coating on conventional metallic bioelectrodes by engineering nanocrystalline domains at the interface between the hydrogel and metallic substrates. It demonstrates the efficacy of this robust, biocompatible, and fatigue-resistant conducting hydrogel coating in cardiac pacing, showcasing its ability to effectively reduce the pacing threshold voltage and enhance the long-term reliability of electric stimulation. This study findings highlight the potential of its approach as a promising design and fabrication strategy for the next generation of seamless bioelectronic interfaces.
Collapse
Affiliation(s)
- Yu Xue
- Department of Mechanical and Energy Engineering, Southern University of Science and Technology, Shenzhen, 518055, China
| | - Xingmei Chen
- Department of Mechanical and Energy Engineering, Southern University of Science and Technology, Shenzhen, 518055, China
| | - Fucheng Wang
- Department of Mechanical and Energy Engineering, Southern University of Science and Technology, Shenzhen, 518055, China
| | - Jingsen Lin
- Department of Mechanical and Energy Engineering, Southern University of Science and Technology, Shenzhen, 518055, China
| | - Ji Liu
- Department of Mechanical and Energy Engineering, Southern University of Science and Technology, Shenzhen, 518055, China
- Shenzhen Key Laboratory of Biomimetic Robotics and Intelligent Systems, Department of Mechanical and Energy Engineering, Southern University of Science and Technology, Shenzhen, 518055, China
- Shenzhen Key Laboratory of Intelligent Robotics and Flexible Manufacturing Systems, Southern University of Science and Technology, Shenzhen, 518055, China
- Guangdong Provincial Key Laboratory of Human-Augmentation and Rehabilitation Robotics in Universities, Southern University of Science and Technology, Shenzhen, 518055, China
| |
Collapse
|
11
|
Kumosa LS. Commonly Overlooked Factors in Biocompatibility Studies of Neural Implants. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2023; 10:e2205095. [PMID: 36596702 PMCID: PMC9951391 DOI: 10.1002/advs.202205095] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/05/2022] [Revised: 11/16/2022] [Indexed: 06/17/2023]
Abstract
Biocompatibility of cutting-edge neural implants, surgical tools and techniques, and therapeutic technologies is a challenging concept that can be easily misjudged. For example, neural interfaces are routinely gauged on how effectively they determine active neurons near their recording sites. Tissue integration and toxicity of neural interfaces are frequently assessed histologically in animal models to determine tissue morphological and cellular changes in response to surgical implantation and chronic presence. A disconnect between histological and efficacious biocompatibility exists, however, as neuronal numbers frequently observed near electrodes do not match recorded neuronal spiking activity. The downstream effects of the myriad surgical and experimental factors involved in such studies are rarely examined when deciding whether a technology or surgical process is biocompatible. Such surgical factors as anesthesia, temperature excursions, bleed incidence, mechanical forces generated, and metabolic conditions are known to have strong systemic and thus local cellular and extracellular consequences. Many tissue markers are extremely sensitive to the physiological state of cells and tissues, thus significantly impacting histological accuracy. This review aims to shed light on commonly overlooked factors that can have a strong impact on the assessment of neural biocompatibility and to address the mismatch between results stemming from functional and histological methods.
Collapse
Affiliation(s)
- Lucas S. Kumosa
- Neuronano Research CenterDepartment of Experimental Medical ScienceMedical FacultyLund UniversityMedicon Village, Byggnad 404 A2, Scheelevägen 8Lund223 81Sweden
| |
Collapse
|
12
|
Liu X, Xu Z, Fu X, Liu Y, Jia H, Yang Z, Zhang J, Wei S, Duan X. Stable, long-term single-neuronal recording from the rat spinal cord with flexible carbon nanotube fiber electrodes. J Neural Eng 2022; 19. [DOI: 10.1088/1741-2552/ac9258] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2022] [Accepted: 09/15/2022] [Indexed: 11/12/2022]
Abstract
Abstract
Objective. Flexible implantable electrodes enable months-long stable recording of single-unit signals from rat brains. Despite extensive efforts in the development of flexible probes for brain recording, thus far there are no conclusions on their application in long-term single neuronal recording from the spinal cord which is more mechanically active. To this end, we realized the chronic recording of single-unit signals from the spinal cord of freely-moving rats using flexible carbon nanotube fiber (CNTF) electrodes. Approach. We developed flexible CNTF electrodes for intraspinal recording. Continuous in vivo impedance monitoring and histology studies were conducted to explore the critical factors determining the longevity of the recording, as well as to illustrate the evolution of the electrode-tissue interface. Gait analysis were performed to evaluate the biosafety of the chronic intraspinal implantation of the CNTF electrodes. Main results. By increasing the insulation thickness of the CNTF electrodes, single-unit signals were continuously recorded from the spinal cord of freely-moving rats without electrode repositioning for 3-4 months. Single neuronal and local field potential activities in response to somatic mechanical stimulation were successfully recorded from the spinal dorsal horns. Histological data demonstrated the ability of the CNTF microelectrodes to form an improved intraspinal interfaces with greatly reduced gliosis compared to their stiff metal counterparts. Continuous impedance monitoring suggested that the longevity of the intraspinal recording with CNTF electrodes was determined by the insulation durability. Gait analysis showed that the chronic presence of the CNTF electrodes caused no noticeable locomotor deficits in rats. Significance. It was found that the chronic recording from the spinal cord faces more stringent requirements on the electrode structural durability than recording from the brain. The stable, long-term intraspinal recording provides unique capabilities for studying the physiological functions of the spinal cord relating to motor, sensation, and autonomic control in both health and disease.
Collapse
|
13
|
Riggins TE, Li W, Purcell EK. Atomic Force Microscope Characterization of the Bending Stiffness and Surface Topography of Silicon and Polymeric Electrodes. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2022; 2022:2348-2352. [PMID: 36085626 DOI: 10.1109/embc48229.2022.9871216] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Implanted electrodes in the brain are increasingly used in research and clinical settings to understand and treat neurological conditions. However, a foreign body response typically occurs after implantation, and glial encapsulation of the device is a commonly observed. Multiple factors affect how gliosis surrounding the implantable electrodes evolves. Characterizing and measuring the surface features and mechanical properties of these devices may allow us to predict where gliosis will occur, and understanding how electrode design features may impact astrogliosis may give researchers a set of design guidelines to follow to maximize chronic performance. In this study, we used atomic force microscopy to measure surface roughness on parylene, polyimide, and silicon devices. Multiple features on microelectrode arrays were measured, including electrode sites, traces, and the bulk substrate. We found differences in surface roughness according to device material, but not device features. We also directly measured the bending stiffness of silicon devices, providing a more exact quantification of this property to corroborate calculated estimates.
Collapse
|
14
|
Lee HS, Eom K, Park M, Ku SB, Lee K, Lee HM. High-density neural recording system design. Biomed Eng Lett 2022; 12:251-261. [DOI: 10.1007/s13534-022-00233-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2022] [Revised: 05/10/2022] [Accepted: 05/20/2022] [Indexed: 10/18/2022] Open
|
15
|
Zhao H, Liu R, Zhang H, Cao P, Liu Z, Li Y. Research Progress on the Flexibility of an Implantable Neural Microelectrode. MICROMACHINES 2022; 13:386. [PMID: 35334680 PMCID: PMC8954487 DOI: 10.3390/mi13030386] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/03/2021] [Revised: 12/25/2021] [Accepted: 01/16/2022] [Indexed: 12/22/2022]
Abstract
Neural microelectrode is the important bridge of information exchange between the human body and machines. By recording and transmitting nerve signals with electrodes, people can control the external machines. At the same time, using electrodes to electrically stimulate nerve tissue, people with long-term brain diseases will be safely and reliably treated. Young's modulus of the traditional rigid electrode probe is not matched well with that of biological tissue, and tissue immune rejection is easy to generate, resulting in the electrode not being able to achieve long-term safety and reliable working. In recent years, the choice of flexible materials and design of electrode structures can achieve modulus matching between electrode and biological tissue, and tissue damage is decreased. This review discusses nerve microelectrodes based on flexible electrode materials and substrate materials. Simultaneously, different structural designs of neural microelectrodes are reviewed. However, flexible electrode probes are difficult to implant into the brain. Only with the aid of certain auxiliary devices, can the implant be safe and reliable. The implantation method of the nerve microelectrode is also reviewed.
Collapse
Affiliation(s)
- Huiqing Zhao
- Beijing Institute of Graphic Communication, Beijing 102600, China
| | - Ruping Liu
- Beijing Institute of Graphic Communication, Beijing 102600, China
| | - Huiling Zhang
- Beijing Institute of Graphic Communication, Beijing 102600, China
| | - Peng Cao
- Beijing Institute of Graphic Communication, Beijing 102600, China
| | - Zilong Liu
- Division of Optics, National Institute of Metrology, Beijing 100029, China
| | - Ye Li
- Beijing Institute of Graphic Communication, Beijing 102600, China
| |
Collapse
|
16
|
Al Abed A, Amatoury J, Khraiche M. Finite Element Modeling of Magnitude and Location of Brain Micromotion Induced Strain for Intracortical Implants. Front Neurosci 2022; 15:727715. [PMID: 35069092 PMCID: PMC8770436 DOI: 10.3389/fnins.2021.727715] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2021] [Accepted: 10/08/2021] [Indexed: 11/13/2022] Open
Abstract
Micromotion-induced stress remains one of the main determinants of life of intracortical implants. This is due to high stress leading to tissue injury, which in turn leads to an immune response coupled with a significant reduction in the nearby neural population and subsequent isolation of the implant. In this work, we develop a finite element model of the intracortical probe-tissue interface to study the effect of implant micromotion, implant thickness, and material properties on the strain levels induced in brain tissue. Our results showed that for stiff implants, the strain magnitude is dependent on the magnitude of the motion, where a micromotion increase from 1 to 10 μm induced an increase in the strain by an order of magnitude. For higher displacement over 10 μm, the change in the strain was relatively smaller. We also showed that displacement magnitude has no impact on the location of maximum strain and addressed the conflicting results in the literature. Further, we explored the effect of different probe materials [i.e., silicon, polyimide (PI), and polyvinyl acetate nanocomposite (PVAc-NC)] on the magnitude, location, and distribution of strain. Finally, we showed that strain distribution across cortical implants was in line with published results on the size of the typical glial response to the neural probe, further reaffirming that strain can be a precursor to the glial response.
Collapse
Affiliation(s)
- Ali Al Abed
- Department of Mechanical Engineering, American University of Beirut, Beirut, Lebanon
| | - Jason Amatoury
- Sleep and Upper Airway Research Group, Biomedical Engineering Program, American University of Beirut, Beirut, Lebanon
| | - Massoud Khraiche
- Neural Engineering and Nanobiosensors Group, Biomedical Engineering Program, American University of Beirut, Beirut, Lebanon
| |
Collapse
|
17
|
Sharafkhani N, Kouzani AZ, Adams SD, Long JM, Lissorgues G, Rousseau L, Orwa JO. Neural tissue-microelectrode interaction: Brain micromotion, electrical impedance, and flexible microelectrode insertion. J Neurosci Methods 2022; 365:109388. [PMID: 34678387 DOI: 10.1016/j.jneumeth.2021.109388] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2021] [Revised: 10/17/2021] [Accepted: 10/17/2021] [Indexed: 10/20/2022]
Abstract
Insertion of a microelectrode into the brain to record/stimulate neurons damages neural tissue and blood vessels and initiates the brain's wound healing response. Due to the large difference between the stiffness of neural tissue and microelectrode, brain micromotion also leads to neural tissue damage and associated local immune response. Over time, following implantation, the brain's response to the tissue damage can result in microelectrode failure. Reducing the microelectrode's cross-sectional dimensions to single-digit microns or using soft materials with elastic modulus close to that of the neural tissue are effective methods to alleviate the neural tissue damage and enhance microelectrode longevity. However, the increase in electrical impedance of the microelectrode caused by reducing the microelectrode contact site's dimensions can decrease the signal-to-noise ratio. Most importantly, the reduced dimensions also lead to a reduction in the critical buckling force, which increases the microelectrode's propensity to buckling during insertion. After discussing brain micromotion, the main source of neural tissue damage, surface modification of the microelectrode contact site is reviewed as a key method for addressing the increase in electrical impedance issue. The review then focuses on recent approaches to aiding insertion of flexible microelectrodes into the brain, including bending stiffness modification, effective length reduction, and application of a magnetic field to pull the electrode. An understanding of the advantages and drawbacks of the developed strategies offers a guide for dealing with the buckling phenomenon during implantation.
Collapse
Affiliation(s)
- Naser Sharafkhani
- School of Engineering, Deakin University, Geelong, VIC 3216, Australia.
| | - Abbas Z Kouzani
- School of Engineering, Deakin University, Geelong, VIC 3216, Australia
| | - Scott D Adams
- School of Engineering, Deakin University, Geelong, VIC 3216, Australia
| | - John M Long
- School of Engineering, Deakin University, Geelong, VIC 3216, Australia
| | | | | | - Julius O Orwa
- School of Engineering, Deakin University, Geelong, VIC 3216, Australia.
| |
Collapse
|
18
|
Turner B, Ramesh S, Menegatti S, Daniele M. Resorbable elastomers for implantable medical devices: highlights and applications. POLYM INT 2021. [DOI: 10.1002/pi.6349] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Affiliation(s)
- Brendan Turner
- Joint Department of Biomedical Engineering North Carolina State University and University of Chapel Hill Raleigh NC USA
- Department of Chemical and Biomolecular Engineering North Carolina State University Raleigh NC USA
| | - Srivatsan Ramesh
- Department of Chemical and Biomolecular Engineering North Carolina State University Raleigh NC USA
| | - Stefano Menegatti
- Department of Chemical and Biomolecular Engineering North Carolina State University Raleigh NC USA
| | - Michael Daniele
- Joint Department of Biomedical Engineering North Carolina State University and University of Chapel Hill Raleigh NC USA
- Department of Electrical and Computer Engineering North Carolina State University Raleigh NC USA
| |
Collapse
|
19
|
Zeng Q, Li X, Zhang S, Deng C, Wu T. Think big, see small—A review of nanomaterials for neural interfaces. NANO SELECT 2021. [DOI: 10.1002/nano.202100256] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022] Open
Affiliation(s)
- Qi Zeng
- Shenzhen Institute of Advanced Technology Chinese Academy of Sciences Shenzhen P.R. China
- College of Physics and Optoelectronic Engineering Shenzhen University Shenzhen P.R. China
| | - Xiaojian Li
- Shenzhen Institute of Advanced Technology Chinese Academy of Sciences Shenzhen P.R. China
- Key Laboratory of Brain Connectome and Manipulation Chinese Academy of Sciences Shenzhen‐Hong Kong Institute of Brain Science‐Shenzhen Fundamental Research Institutions Shenzhen P.R. China
| | - Shiyun Zhang
- Shenzhen Institute of Advanced Technology Chinese Academy of Sciences Shenzhen P.R. China
| | - Chunshan Deng
- Shenzhen Institute of Advanced Technology Chinese Academy of Sciences Shenzhen P.R. China
- Key Laboratory of Brain Connectome and Manipulation Chinese Academy of Sciences Shenzhen‐Hong Kong Institute of Brain Science‐Shenzhen Fundamental Research Institutions Shenzhen P.R. China
| | - Tianzhun Wu
- Shenzhen Institute of Advanced Technology Chinese Academy of Sciences Shenzhen P.R. China
- Key Laboratory of Health Bioinformatics Chinese Academy of Sciences Shenzhen P.R. China
| |
Collapse
|
20
|
Cho YH, Park YG, Kim S, Park JU. 3D Electrodes for Bioelectronics. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2021; 33:e2005805. [PMID: 34013548 DOI: 10.1002/adma.202005805] [Citation(s) in RCA: 24] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/26/2020] [Revised: 10/04/2020] [Indexed: 05/08/2023]
Abstract
In recent studies related to bioelectronics, significant efforts have been made to form 3D electrodes to increase the effective surface area or to optimize the transfer of signals at tissue-electrode interfaces. Although bioelectronic devices with 2D and flat electrode structures have been used extensively for monitoring biological signals, these 2D planar electrodes have made it difficult to form biocompatible and uniform interfaces with nonplanar and soft biological systems (at the cellular or tissue levels). Especially, recent biomedical applications have been expanding rapidly toward 3D organoids and the deep tissues of living animals, and 3D bioelectrodes are getting significant attention because they can reach the deep regions of various 3D tissues. An overview of recent studies on 3D bioelectronic devices, such as the use of electrical stimulations and the recording of neural signals from biological subjects, is presented. Subsequently, the recent developments in materials and fabrication processing to 3D micro- and nanostructures are introduced, followed by broad applications of these 3D bioelectronic devices at various in vitro and in vivo conditions.
Collapse
Affiliation(s)
- Yo Han Cho
- Nano Science Technology Institute, Department of Materials Science and Engineering, Yonsei University, Seoul, 03722, Republic of Korea
- Center for Nanomedicine, Institute for Basic Science (IBS), Seoul, 03722, Republic of Korea
- Graduate Program of Nano Biomedical Engineering (NanoBME), Advanced Science Institute, Yonsei University, Seoul, 03722, Republic of Korea
| | - Young-Geun Park
- Nano Science Technology Institute, Department of Materials Science and Engineering, Yonsei University, Seoul, 03722, Republic of Korea
- Center for Nanomedicine, Institute for Basic Science (IBS), Seoul, 03722, Republic of Korea
- Graduate Program of Nano Biomedical Engineering (NanoBME), Advanced Science Institute, Yonsei University, Seoul, 03722, Republic of Korea
| | - Sumin Kim
- Nano Science Technology Institute, Department of Materials Science and Engineering, Yonsei University, Seoul, 03722, Republic of Korea
- Center for Nanomedicine, Institute for Basic Science (IBS), Seoul, 03722, Republic of Korea
- Graduate Program of Nano Biomedical Engineering (NanoBME), Advanced Science Institute, Yonsei University, Seoul, 03722, Republic of Korea
| | - Jang-Ung Park
- Nano Science Technology Institute, Department of Materials Science and Engineering, Yonsei University, Seoul, 03722, Republic of Korea
- Center for Nanomedicine, Institute for Basic Science (IBS), Seoul, 03722, Republic of Korea
- Graduate Program of Nano Biomedical Engineering (NanoBME), Advanced Science Institute, Yonsei University, Seoul, 03722, Republic of Korea
| |
Collapse
|
21
|
Kumosa LS, Schouenborg J. Profound alterations in brain tissue linked to hypoxic episode after device implantation. Biomaterials 2021; 278:121143. [PMID: 34653937 DOI: 10.1016/j.biomaterials.2021.121143] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2021] [Accepted: 09/20/2021] [Indexed: 12/17/2022]
Abstract
To enable authentic interfacing with neuronal structures in the brain, preventing alterations of tissue during implantation of devices is critical. By transiently implanting oxygen microsensors into rat cortex cerebri for 2 h, substantial and long lasting (>1 h) hypoxia is routinely generated in surrounding tissues; this hypoxia is linked to implantation generated compressive forces. Preferential loss of larger neurons and reduced metabolic components in surviving neurons indicates decreased viability one week after such hypoxic, compressive implantations. By devising an implantation method that relaxes compressive forces; magnitude and duration of hypoxia generated following such an implantation are ameliorated and neurons appear similar to naïve tissues. In line with these observations, astrocyte proliferation was significantly more pronounced for more hypoxic, compressive implantations. Surprisingly, astrocyte processes were frequently found to traverse cellular boundaries into nearby neuronal nuclei, indicating injury induction of a previously not described astrocyte-neuron interaction. Found more frequently in less hypoxic, force-relaxed insertions and thus correlating to a more beneficial outcome, this finding may suggest a novel protective mechanism. In conclusion, substantial and long lasting insertion induced hypoxia around brain implants, a previously overlooked factor, is linked to significant adverse alterations in nervous tissue.
Collapse
Affiliation(s)
- Lucas S Kumosa
- Neuronano Research Center, Faculty of Medicine, Lund University, Scheelevägen 2, Medicon Village 404A2, 223 81, Lund, Sweden.
| | - Jens Schouenborg
- Neuronano Research Center, Faculty of Medicine, Lund University, Scheelevägen 2, Medicon Village 404A2, 223 81, Lund, Sweden; NanoLund, Lund University, Professorsgatan 1, 223 63, Lund, Sweden.
| |
Collapse
|
22
|
Srikantharajah K, Medinaceli Quintela R, Doerenkamp K, Kampa BM, Musall S, Rothermel M, Offenhäusser A. Minimally-invasive insertion strategy and in vivo evaluation of multi-shank flexible intracortical probes. Sci Rep 2021; 11:18920. [PMID: 34556704 PMCID: PMC8460634 DOI: 10.1038/s41598-021-97940-x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2021] [Accepted: 08/26/2021] [Indexed: 11/16/2022] Open
Abstract
Chronically implanted neural probes are powerful tools to decode brain activity however, recording population and spiking activity over long periods remains a major challenge. Here, we designed and fabricated flexible intracortical Michigan-style arrays with a shank cross-section per electrode of 250 μm[Formula: see text] utilizing the polymer paryleneC with the goal to improve the immune acceptance. As flexible neural probes are unable to penetrate the brain due to the low buckling force threshold, a tissue-friendly insertion system was developed by reducing the effective shank length. The insertion strategy enabled the implantation of the four, bare, flexible shanks up to 2 mm into the mouse brain without increasing the implantation footprint and therefore, minimizing the acute trauma. In acute recordings from the mouse somatosensory cortex and the olfactory bulb, we demonstrated that the flexible probes were able to simultaneously detect local field potentials as well as single and multi-unit activity. Additionally, the flexible arrays outperformed stiff probes with respect to yield of single unit activity. Following the successful in vivo validation, we further improved the microfabrication towards a double-metal-layer process, and were able to double the number of electrodes per shank by keeping the shank width resulting in a cross-section per electrode of 118 μm[Formula: see text].
Collapse
Affiliation(s)
- Kagithiri Srikantharajah
- Bioelectronics, Institute of Biological Information Processing-3, Forschungszentrum Jülich, Jülich, Germany
- RWTH Aachen University, Aachen, Germany
| | - Renata Medinaceli Quintela
- Institute for Physiology and Cell Biology, University of Veterinary Medicine, Foundation, Hannover, Germany
| | - Kerstin Doerenkamp
- Department of Neurophysiology, Institute for Biology II, RWTH Aachen University, Aachen, Germany
| | - Björn M Kampa
- Department of Neurophysiology, Institute for Biology II, RWTH Aachen University, Aachen, Germany
- JARA BRAIN, Institute for Neuroscience and Medicine, Forschungszentrum Jülich, Jülich, Germany
| | - Simon Musall
- Bioelectronics, Institute of Biological Information Processing-3, Forschungszentrum Jülich, Jülich, Germany
| | - Markus Rothermel
- Institute for Physiology and Cell Biology, University of Veterinary Medicine, Foundation, Hannover, Germany
| | - Andreas Offenhäusser
- Bioelectronics, Institute of Biological Information Processing-3, Forschungszentrum Jülich, Jülich, Germany.
- RWTH Aachen University, Aachen, Germany.
| |
Collapse
|
23
|
Intracortical Microelectrode Array Unit Yield under Chronic Conditions: A Comparative Evaluation. MICROMACHINES 2021; 12:mi12080972. [PMID: 34442594 PMCID: PMC8400387 DOI: 10.3390/mi12080972] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/21/2021] [Revised: 08/10/2021] [Accepted: 08/12/2021] [Indexed: 01/01/2023]
Abstract
While microelectrode arrays (MEAs) offer the promise of elucidating functional neural circuitry and serve as the basis for a cortical neuroprosthesis, the challenge of designing and demonstrating chronically reliable technology remains. Numerous studies report “chronic” data but the actual time spans and performance measures corresponding to the experimental work vary. In this study, we reviewed the experimental durations that constitute chronic studies across a range of MEA types and animal species to gain an understanding of the widespread variability in reported study duration. For rodents, which are the most commonly used animal model in chronic studies, we examined active electrode yield (AEY) for different array types as a means to contextualize the study duration variance, as well as investigate and interpret the performance of custom devices in comparison to conventional MEAs. We observed wide-spread variance within species for the chronic implantation period and an AEY that decayed linearly in rodent models that implanted commercially-available devices. These observations provide a benchmark for comparing the performance of new technologies and highlight the need for consistency in chronic MEA studies. Additionally, to fully derive performance under chronic conditions, the duration of abiotic failure modes, biological processes induced by indwelling probes, and intended application of the device are key determinants.
Collapse
|
24
|
Sridharan A, Muthuswamy J. Soft, Conductive, Brain-Like, Coatings at Tips of Microelectrodes Improve Electrical Stability under Chronic, In Vivo Conditions. MICROMACHINES 2021; 12:761. [PMID: 34203234 PMCID: PMC8306035 DOI: 10.3390/mi12070761] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/19/2021] [Revised: 06/22/2021] [Accepted: 06/25/2021] [Indexed: 01/27/2023]
Abstract
Several recent studies have reported improved histological and electrophysiological outcomes with soft neural interfaces that have elastic moduli ranging from 10 s of kPa to hundreds of MPa. However, many of these soft interfaces use custom fabrication processes. We test the hypothesis that a readily adoptable fabrication process for only coating the tips of microelectrodes with soft brain-like (elastic modulus of ~5 kPa) material improves the long-term electrical performance of neural interfaces. Conventional tungsten microelectrodes (n = 9 with soft coatings and n = 6 uncoated controls) and Pt/Ir microelectrodes (n = 16 with soft coatings) were implanted in six animals for durations ranging from 5 weeks to over 1 year in a subset of rats. Electrochemical impedance spectroscopy was used to assess the quality of the brain tissue-electrode interface under chronic conditions. Neural recordings were assessed for unit activity and signal quality. Electrodes with soft, silicone coatings showed relatively stable electrical impedance characteristics over 6 weeks to >1 year compared to the uncoated control electrodes. Single unit activity recorded by coated electrodes showed larger peak-to-peak amplitudes and increased number of detectable neurons compared to uncoated controls over 6-7 weeks. We demonstrate the feasibility of using a readily translatable process to create brain-like soft interfaces that can potentially overcome variable performance associated with chronic rigid neural interfaces.
Collapse
Affiliation(s)
| | - Jit Muthuswamy
- School of Biological and Health Systems Engineering, Ira A. Fulton School of Engineering, Arizona State University, Tempe, AZ 85287-9709, USA;
| |
Collapse
|
25
|
Recent Advancements in Polythiophene-Based Materials and their Biomedical, Geno Sensor and DNA Detection. Int J Mol Sci 2021; 22:ijms22136850. [PMID: 34202199 PMCID: PMC8268102 DOI: 10.3390/ijms22136850] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2021] [Revised: 06/20/2021] [Accepted: 06/20/2021] [Indexed: 11/17/2022] Open
Abstract
In this review, the unique properties of intrinsically conducting polymer (ICP) in biomedical engineering fields are summarized. Polythiophene and its valuable derivatives are known as potent materials that can broadly be applied in biosensors, DNA, and gene delivery applications. Moreover, this material plays a basic role in curing and promoting anti-HIV drugs. Some of the thiophene’s derivatives were chosen for different experiments and investigations to study their behavior and effects while binding with different materials and establishing new compounds. Many methods were considered for electrode coating and the conversion of thiophene to different monomers to improve their functions and to use them for a new generation of novel medical usages. It is believed that polythiophenes and their derivatives can be used in the future as a substitute for many old-fashioned ways of creating chemical biosensors polymeric materials and also drugs with lower side effects yet having a more effective response. It can be noted that syncing biochemistry with biomedical engineering will lead to a new generation of science, especially one that involves high-efficiency polymers. Therefore, since polythiophene can be customized with many derivatives, some of the novel combinations are covered in this review.
Collapse
|
26
|
Crawford L, Wyatt M, Bryers J, Ratner B. Biocompatibility Evolves: Phenomenology to Toxicology to Regeneration. Adv Healthc Mater 2021; 10:e2002153. [PMID: 33829678 PMCID: PMC8221530 DOI: 10.1002/adhm.202002153] [Citation(s) in RCA: 44] [Impact Index Per Article: 14.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2020] [Revised: 02/26/2021] [Indexed: 12/20/2022]
Abstract
The word "biocompatibility," is inconsistent with the observations of healing for so-called biocompatible biomaterials. The vast majority of the millions of medical implants in humans today, presumably "biocompatible," are walled off by a dense, avascular, crosslinked collagen capsule, hardly suggestive of life or compatibility. In contrast, one is now seeing examples of implant biomaterials that lead to a vascularized reconstruction of localized tissue, a biological reaction different from traditional biocompatible materials that generate a foreign body capsule. Both the encapsulated biomaterials and the reconstructive biomaterials qualify as "biocompatible" by present day measurements of biocompatibility. Yet, this new generation of materials would seem to heal "compatibly" with the living organism, where older biomaterials are isolated from the living organism by the dense capsule. This review/perspective article will explore this biocompatibility etymological conundrum by reviewing the history of the concepts around biocompatibility, today's standard methods for assessing biocompatibility, a contemporary view of the foreign body reaction and finally, a compendium of new biomaterials that heal without the foreign body capsule. A new definition of biocompatibility is offered here to address advances in biomaterials design leading to biomaterials that heal into the body in a facile manner.
Collapse
Affiliation(s)
- Lars Crawford
- Department of Bioengineering, University of Washington, Seattle, WA, 98195, USA
| | - Meghan Wyatt
- Department of Bioengineering, University of Washington, Seattle, WA, 98195, USA
| | - James Bryers
- Department of Bioengineering, University of Washington, Seattle, WA, 98195, USA
| | - Buddy Ratner
- Department of Bioengineering, University of Washington, Seattle, WA, 98195, USA
| |
Collapse
|
27
|
Kim K, Sung C, Lee J, Won J, Jeon W, Seo S, Yoon K, Park S. Computational and Histological Analyses for Investigating Mechanical Interaction of Thermally Drawn Fiber Implants with Brain Tissue. MICROMACHINES 2021; 12:mi12040394. [PMID: 33918390 PMCID: PMC8067235 DOI: 10.3390/mi12040394] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/19/2021] [Revised: 03/25/2021] [Accepted: 03/31/2021] [Indexed: 01/24/2023]
Abstract
The development of a compliant neural probe is necessary to achieve chronic implantation with minimal signal loss. Although fiber-based neural probes fabricated by the thermal drawing process have been proposed as a solution, their long-term effect on the brain has not been thoroughly investigated. Here, we examined the mechanical interaction of thermally drawn fiber implants with neural tissue through computational and histological analyses. Specifically, finite element analysis and immunohistochemistry were conducted to evaluate the biocompatibility of various fiber implants made with different base materials (steel, silica, polycarbonate, and hydrogel). Moreover, the effects of the coefficient of friction and geometric factors including aspect ratio and the shape of the cross-section on the strain were investigated with the finite element model. As a result, we observed that the fiber implants fabricated with extremely softer material such as hydrogel exhibited significantly lower strain distribution and elicited a reduced immune response. In addition, the implants with higher coefficient of friction (COF) and/or circular cross-sections showed a lower strain distribution and smaller critical volume. This work suggests the materials and design factors that need to be carefully considered to develop future fiber-based neural probes to minimize mechanical invasiveness.
Collapse
Affiliation(s)
- Kanghyeon Kim
- Department of Bio and Brain Engineering, Korea Advanced Institute of Science and Technology (KAIST), Deajeon 34141, Korea; (K.K.); (C.S.); (W.J.)
| | - Changhoon Sung
- Department of Bio and Brain Engineering, Korea Advanced Institute of Science and Technology (KAIST), Deajeon 34141, Korea; (K.K.); (C.S.); (W.J.)
| | - Jungjoon Lee
- Program of Brain and Cognitive Engineering, Korea Advanced Institute of Science and Technology (KAIST), Deajeon 34141, Korea; (J.L.); (J.W.)
| | - Joonhee Won
- Program of Brain and Cognitive Engineering, Korea Advanced Institute of Science and Technology (KAIST), Deajeon 34141, Korea; (J.L.); (J.W.)
| | - Woojin Jeon
- Department of Bio and Brain Engineering, Korea Advanced Institute of Science and Technology (KAIST), Deajeon 34141, Korea; (K.K.); (C.S.); (W.J.)
| | - Seungbeom Seo
- Department of Electrical Engineering, Ulsan National Institute of Science and Technology (UNIST), Ulsan 44919, Korea;
| | - Kyungho Yoon
- Center for Healthcare Robotics, Korea Institute of Science and Technology (KIST), Seoul 02792, Korea
- Division of Bio-Medical Science and Technology, KIST School, Korea University of Science and Technology, Seoul 02792, Korea
- Correspondence: (K.Y.); (S.P.)
| | - Seongjun Park
- Department of Bio and Brain Engineering, Korea Advanced Institute of Science and Technology (KAIST), Deajeon 34141, Korea; (K.K.); (C.S.); (W.J.)
- Program of Brain and Cognitive Engineering, Korea Advanced Institute of Science and Technology (KAIST), Deajeon 34141, Korea; (J.L.); (J.W.)
- KAIST Institute of Health Science and Technology (KIHST), Korea Advanced Institute of Science and Technology (KAIST), Daejeon 34141, Korea
- Correspondence: (K.Y.); (S.P.)
| |
Collapse
|
28
|
Ramezani Z, Seo KJ, Fang H. Hybrid Electrical and Optical Neural Interfaces. JOURNAL OF MICROMECHANICS AND MICROENGINEERING : STRUCTURES, DEVICES, AND SYSTEMS 2021; 31:044002. [PMID: 34177136 PMCID: PMC8232899 DOI: 10.1088/1361-6439/abeb30] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Neural interfaces bridge the nervous system and the outside world by recording and stimulating neurons. Combining electrical and optical modalities in a single, hybrid neural interface system could lead to complementary and powerful new ways to explore the brain. It has gained robust and exciting momentum recently in neuroscience and neural engineering research. Here, we review developments in the past several years aiming to achieve such hybrid electrical and optical microsystem platforms. Specifically, we cover three major categories of technological advances: transparent neuroelectrodes, optical neural fibers with electrodes, and neural probes/grids integrating electrodes and microscale light-emitting diodes. We discuss examples of these probes tailored to combine electrophysiological recording with optical imaging or optical neural stimulation of the brain and possible directions of future innovation.
Collapse
Affiliation(s)
| | | | - Hui Fang
- Department of Electrical and Computer Engineering
- Department of Mechanical and Industrial Engineering
- Department of Bioengineering, Northeastern University, Boston, Massachusetts 02115, USA
| |
Collapse
|
29
|
Dubaniewicz M, Eles JR, Lam S, Song S, Cambi F, Sun D, Wellman SM, Kozai TDY. Inhibition of Na +/H +exchanger modulates microglial activation and scar formation following microelectrode implantation. J Neural Eng 2021; 18. [PMID: 33621208 DOI: 10.1088/1741-2552/abe8f1] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2020] [Accepted: 02/23/2021] [Indexed: 11/12/2022]
Abstract
Objective.Intracortical microelectrodes are an important tool for neuroscience research and have great potential for clinical use. However, the use of microelectrode arrays to treat neurological disorders and control prosthetics is limited by biological challenges such as glial scarring, which can impair chronic recording performance. Microglia activation is an early and prominent contributor to glial scarring. After insertion of an intracortical microelectrode, nearby microglia transition into a state of activation, migrate, and encapsulate the device. Na+/H+exchanger isoform-1 (NHE-1) is involved in various microglial functions, including their polarity and motility, and has been implicated in pro-inflammatory responses to tissue injury. HOE-642 (cariporide) is an inhibitor of NHE-1 and has been shown to depress microglial activation and inflammatory response in brain injury models.Approach.In this study, the effects of HOE-642 treatment on microglial interactions to intracortical microelectrodes was evaluated using two-photon microscopyin vivo.Main results.The rate at which microglia processes and soma migrate in response to electrode implantation was unaffected by HOE-642 administration. However, HOE-642 administration effectively reduced the radius of microglia activation at 72 h post-implantation from 222.2µm to 177.9µm. Furthermore, treatment with HOE-642 significantly reduced microglial encapsulation of implanted devices at 5 h post-insertion from 50.7 ± 6.0% to 8.9 ± 6.1%, which suggests an NHE-1-specific mechanism mediating microglia reactivity and gliosis during implantation injury.Significance.This study implicates NHE-1 as a potential target of interest in microglial reactivity and HOE-642 as a potential treatment to attenuate the glial response and scar formation around implanted intracortical microelectrodes.
Collapse
Affiliation(s)
- Mitchell Dubaniewicz
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA, United States of America
| | - James R Eles
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA, United States of America.,Center for Neural Basis of Cognition, Pittsburgh, PA, United States of America
| | - Stephanie Lam
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA, United States of America.,Center for Neural Basis of Cognition, Pittsburgh, PA, United States of America
| | - Shanshan Song
- Department of Neurology, University of Pittsburgh, Pittsburgh, PA, United States of America
| | - Franca Cambi
- Veterans Administration Pittsburgh, Pittsburgh, PA, United States of America.,Department of Neurology, University of Pittsburgh, Pittsburgh, PA, United States of America
| | - Dandan Sun
- Veterans Administration Pittsburgh, Pittsburgh, PA, United States of America.,Department of Neurology, University of Pittsburgh, Pittsburgh, PA, United States of America
| | - Steven M Wellman
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA, United States of America.,Center for Neural Basis of Cognition, Pittsburgh, PA, United States of America
| | - Takashi D Y Kozai
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA, United States of America.,Center for Neural Basis of Cognition, Pittsburgh, PA, United States of America.,Center for Neuroscience, University of Pittsburgh, Pittsburgh, PA, United States of America.,McGowan Institute of Regenerative Medicine, University of Pittsburgh, Pittsburgh, PA, United States of America.,NeuroTech Center, University of Pittsburgh Brain Institute, Pittsburgh, PA, United States of America
| |
Collapse
|
30
|
How is flexible electronics advancing neuroscience research? Biomaterials 2020; 268:120559. [PMID: 33310538 DOI: 10.1016/j.biomaterials.2020.120559] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2020] [Revised: 11/16/2020] [Accepted: 11/18/2020] [Indexed: 02/07/2023]
Abstract
Innovative neurotechnology must be leveraged to experimentally answer the multitude of pressing questions in modern neuroscience. Driven by the desire to address the existing neuroscience problems with newly engineered tools, we discuss in this review the benefits of flexible electronics for neuroscience studies. We first introduce the concept and define the properties of flexible and stretchable electronics. We then categorize the four dimensions where flexible electronics meets the demands of modern neuroscience: chronic stability, interfacing multiple structures, multi-modal compatibility, and neuron-type-specific recording. Specifically, with the bending stiffness now approaching that of neural tissue, implanted flexible electronic devices produce little shear motion, minimizing chronic immune responses and enabling recording and stimulation for months, and even years. The unique mechanical properties of flexible electronics also allow for intimate conformation to the brain, the spinal cord, peripheral nerves, and the retina. Moreover, flexible electronics enables optogenetic stimulation, microfluidic drug delivery, and neural activity imaging during electrical stimulation and recording. Finally, flexible electronics can enable neuron-type identification through analysis of high-fidelity recorded action potentials facilitated by its seamless integration with the neural circuitry. We argue that flexible electronics will play an increasingly important role in neuroscience studies and neurological therapies via the fabrication of neuromorphic devices on flexible substrates and the development of enhanced methods of neuronal interpenetration.
Collapse
|
31
|
Almasri RM, AlChamaa W, Tehrani-Bagha AR, Khraiche ML. Highly Flexible Single-Unit Resolution All Printed Neural Interface on a Bioresorbable Backbone. ACS APPLIED BIO MATERIALS 2020; 3:7040-7051. [DOI: 10.1021/acsabm.0c00895] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Reem M. Almasri
- Neural Engineering and Nanobiosensors Group, Biomedical Engineering Program, Maroun Semaan Faculty of Engineering and Architecture, American University of Beirut, Beirut 1107 2020, Lebanon
| | - Walid AlChamaa
- Neural Engineering and Nanobiosensors Group, Biomedical Engineering Program, Maroun Semaan Faculty of Engineering and Architecture, American University of Beirut, Beirut 1107 2020, Lebanon
| | - Ali Reza Tehrani-Bagha
- Department of Chemical Engineering and Advanced Energy, American University of Beirut, Beirut 1107 2020, Lebanon
| | - Massoud L. Khraiche
- Neural Engineering and Nanobiosensors Group, Biomedical Engineering Program, Maroun Semaan Faculty of Engineering and Architecture, American University of Beirut, Beirut 1107 2020, Lebanon
| |
Collapse
|
32
|
He F, Lycke R, Ganji M, Xie C, Luan L. Ultraflexible Neural Electrodes for Long-Lasting Intracortical Recording. iScience 2020; 23:101387. [PMID: 32745989 PMCID: PMC7398974 DOI: 10.1016/j.isci.2020.101387] [Citation(s) in RCA: 28] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2020] [Revised: 06/22/2020] [Accepted: 07/16/2020] [Indexed: 11/16/2022] Open
Abstract
Implanted electrodes provide one of the most important neurotechniques for fundamental and translational neurosciences by permitting time-resolved electrical detection of individual neurons in vivo. However, conventional rigid electrodes typically cannot provide stable, long-lasting recordings. Numerous interwoven biotic and abiotic factors at the tissue-electrode interface lead to short- and long-term instability of the recording performance. Making neural electrodes flexible provides a promising approach to mitigate these challenges on the implants and at the tissue-electrode interface. Here we review the recent progress of ultraflexible neural electrodes and discuss the engineering principles, the material properties, and the implantation strategies to achieve stable tissue-electrode interface and reliable unit recordings in living brains.
Collapse
Affiliation(s)
- Fei He
- Department of Electrical and Computer Engineering, Rice University, 6100 Main Street, Houston, TX 77005, USA; NeuroEngineering Initiative, Rice University, 6500 Main Street, Houston, TX 77005, USA
| | - Roy Lycke
- Department of Electrical and Computer Engineering, Rice University, 6100 Main Street, Houston, TX 77005, USA; NeuroEngineering Initiative, Rice University, 6500 Main Street, Houston, TX 77005, USA; Department of Biomedical Engineering, University of Texas at Austin, 107 Dean Keeton, Austin, TX 78712, USA
| | - Mehran Ganji
- Department of Electrical and Computer Engineering, Rice University, 6100 Main Street, Houston, TX 77005, USA; NeuroEngineering Initiative, Rice University, 6500 Main Street, Houston, TX 77005, USA; Department of Biomedical Engineering, University of Texas at Austin, 107 Dean Keeton, Austin, TX 78712, USA
| | - Chong Xie
- Department of Electrical and Computer Engineering, Rice University, 6100 Main Street, Houston, TX 77005, USA; NeuroEngineering Initiative, Rice University, 6500 Main Street, Houston, TX 77005, USA; Department of Bioengineering, Rice University, 6100 Main Street, Houston, TX 77005, USA
| | - Lan Luan
- Department of Electrical and Computer Engineering, Rice University, 6100 Main Street, Houston, TX 77005, USA; NeuroEngineering Initiative, Rice University, 6500 Main Street, Houston, TX 77005, USA; Department of Bioengineering, Rice University, 6100 Main Street, Houston, TX 77005, USA.
| |
Collapse
|
33
|
Fernández E, Alfaro A, González-López P. Toward Long-Term Communication With the Brain in the Blind by Intracortical Stimulation: Challenges and Future Prospects. Front Neurosci 2020; 14:681. [PMID: 32848535 PMCID: PMC7431631 DOI: 10.3389/fnins.2020.00681] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/24/2019] [Accepted: 06/03/2020] [Indexed: 11/15/2022] Open
Abstract
The restoration of a useful visual sense in a profoundly blind person by direct electrical stimulation of the visual cortex has been a subject of study for many years. However, the field of cortically based sight restoration has made few advances in the last few decades, and many problems remain. In this context, the scientific and technological problems associated with safe and effective communication with the brain are very complex, and there are still many unresolved issues delaying its development. In this work, we review some of the biological and technical issues that still remain to be solved, including long-term biotolerability, the number of electrodes required to provide useful vision, and the delivery of information to the implants. Furthermore, we emphasize the possible role of the neuroplastic changes that follow vision loss in the success of this approach. We propose that increased collaborations among clinicians, basic researchers, and neural engineers will enhance our ability to send meaningful information to the brain and restore a limited but useful sense of vision to many blind individuals.
Collapse
Affiliation(s)
- Eduardo Fernández
- Institute of Bioengineering, Universidad Miguel Hernández, Elche, Spain
- Center for Biomedical Research in the Network in Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN), Madrid, Spain
- John A. Moran Eye Center, University of Utah, Salt Lake City, UT, United States
| | - Arantxa Alfaro
- Center for Biomedical Research in the Network in Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN), Madrid, Spain
- Hospital Vega Baja, Orihuela, Spain
| | - Pablo González-López
- Institute of Bioengineering, Universidad Miguel Hernández, Elche, Spain
- Hospital General Universitario de Alicante, Alicante, Spain
| |
Collapse
|
34
|
Du M, Huang L, Zheng J, Xi Y, Dai Y, Zhang W, Yan W, Tao G, Qiu J, So K, Ren C, Zhou S. Flexible Fiber Probe for Efficient Neural Stimulation and Detection. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2020; 7:2001410. [PMID: 32775173 PMCID: PMC7404151 DOI: 10.1002/advs.202001410] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/17/2020] [Indexed: 05/24/2023]
Abstract
Functional probes are a leading contender for the recognition and manipulation of nervous behavior and are characterized by substantial scientific and technological potential. Despite the recent development of functional neural probes, a flexible biocompatible probe unit that allows for long-term simultaneous stimulation and signaling is still an important task. Here, a category of flexible tiny multimaterial fiber probes (<0.3 g) is described in which the metal electrodes are regularly embedded inside a biocompatible polymer fiber with a double-clad optical waveguide by thermal drawing. Significantly, this arrangement enables great improvement in mechanical properties, achieves high optical transmission (>90%), and effectively minimizes the impedance (by up to one order of magnitude) of the probe. This ability allows to realize long-term (at least 10 weeks) simultaneous optical stimulation and neural recording at the single-cell level in behaving mice with signal-to-noise ratio (SNR = 30 dB) that is more than 6 times that of the benchmark probe such as an all-polymer fiber.
Collapse
Affiliation(s)
- Minghui Du
- State Key Laboratory of Luminescent Materials and DevicesSchool of Materials Science and EngineeringSouth China University of TechnologyGuangzhou510640China
- Guangdong Provincial Key Laboratory of Fibre Laser Materials and Applied TechniquesGuangdong Engineering Technology Research and Development Center of Special Optical Fibre Materials and DevicesGuangzhou510640China
| | - Lu Huang
- Guangdong‐Hongkong‐Macau Institute of CNS RegenerationMinistry of Education CNS Regeneration Collaborative Joint LaboratoryJinan UniversityGuangzhou510632China
- Department of Neurology and Stroke CenterThe First Affiliated Hospital of Jinan UniversityGuangzhou510632China
| | - Jiajun Zheng
- Guangdong‐Hongkong‐Macau Institute of CNS RegenerationMinistry of Education CNS Regeneration Collaborative Joint LaboratoryJinan UniversityGuangzhou510632China
| | - Yue Xi
- Guangdong‐Hongkong‐Macau Institute of CNS RegenerationMinistry of Education CNS Regeneration Collaborative Joint LaboratoryJinan UniversityGuangzhou510632China
| | - Yi Dai
- State Key Laboratory of Luminescent Materials and DevicesSchool of Materials Science and EngineeringSouth China University of TechnologyGuangzhou510640China
- Guangdong Provincial Key Laboratory of Fibre Laser Materials and Applied TechniquesGuangdong Engineering Technology Research and Development Center of Special Optical Fibre Materials and DevicesGuangzhou510640China
| | - Weida Zhang
- State Key Laboratory of Luminescent Materials and DevicesSchool of Materials Science and EngineeringSouth China University of TechnologyGuangzhou510640China
- Guangdong Provincial Key Laboratory of Fibre Laser Materials and Applied TechniquesGuangdong Engineering Technology Research and Development Center of Special Optical Fibre Materials and DevicesGuangzhou510640China
| | - Wei Yan
- Research Laboratory of ElectronicsMassachusetts Institute of Technology (MIT)CambridgeMA02139USA
| | - Guangming Tao
- School of Optical and Electronic InformationWuhan National Laboratory for OptoelectronicsHuazhong University of Science and TechnologyWuhan430074China
| | - Jianrong Qiu
- College of Optical Science and EngineeringState Key Laboratory of Modern Optical InstrumentationZhejiang UniversityHangzhou310027China
| | - Kwok‐Fai So
- Guangdong‐Hongkong‐Macau Institute of CNS RegenerationMinistry of Education CNS Regeneration Collaborative Joint LaboratoryJinan UniversityGuangzhou510632China
| | - Chaoran Ren
- Guangdong‐Hongkong‐Macau Institute of CNS RegenerationMinistry of Education CNS Regeneration Collaborative Joint LaboratoryJinan UniversityGuangzhou510632China
- Guangzhou Regenerative Medicine and Health Guangdong LaboratoryGuangzhou510530China
- Co‐innovation Center of NeuroregenerationNantong UniversityNantong226001China
- Center for Brain Science and Brain‐Inspired IntelligenceGuangdong‐Hong Kong‐Macao Greater Bay AreaGuangzhou510000China
| | - Shifeng Zhou
- State Key Laboratory of Luminescent Materials and DevicesSchool of Materials Science and EngineeringSouth China University of TechnologyGuangzhou510640China
- Guangdong Provincial Key Laboratory of Fibre Laser Materials and Applied TechniquesGuangdong Engineering Technology Research and Development Center of Special Optical Fibre Materials and DevicesGuangzhou510640China
| |
Collapse
|
35
|
Optical Waveguides and Integrated Optical Devices for Medical Diagnosis, Health Monitoring and Light Therapies. SENSORS 2020; 20:s20143981. [PMID: 32709072 PMCID: PMC7411870 DOI: 10.3390/s20143981] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/10/2020] [Revised: 06/26/2020] [Accepted: 07/13/2020] [Indexed: 02/06/2023]
Abstract
Optical waveguides and integrated optical devices are promising solutions for many applications, such as medical diagnosis, health monitoring and light therapies. Despite the many existing reviews focusing on the materials that these devices are made from, a systematic review that relates these devices to the various materials, fabrication processes, sensing methods and medical applications is still seldom seen. This work is intended to link these multidisciplinary fields, and to provide a comprehensive review of the recent advances of these devices. Firstly, the optical and mechanical properties of optical waveguides based on glass, polymers and heterogeneous materials and fabricated via various processes are thoroughly discussed, together with their applications for medical purposes. Then, the fabrication processes and medical implementations of integrated passive and active optical devices with sensing modules are introduced, which can be used in many medical fields such as drug delivery and cardiovascular healthcare. Thirdly, wearable optical sensing devices based on light sensing methods such as colorimetry, fluorescence and luminescence are discussed. Additionally, the wearable optical devices for light therapies are introduced. The review concludes with a comprehensive summary of these optical devices, in terms of their forms, materials, light sources and applications.
Collapse
|
36
|
Stiller AM, Usoro JO, Lawson J, Araya B, González-González MA, Danda VR, Voit WE, Black BJ, Pancrazio JJ. Mechanically Robust, Softening Shape Memory Polymer Probes for Intracortical Recording. MICROMACHINES 2020; 11:E619. [PMID: 32630553 PMCID: PMC7344527 DOI: 10.3390/mi11060619] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/21/2020] [Revised: 06/22/2020] [Accepted: 06/23/2020] [Indexed: 02/06/2023]
Abstract
While intracortical microelectrode arrays (MEAs) may be useful in a variety of basic and clinical scenarios, their implementation is hindered by a variety of factors, many of which are related to the stiff material composition of the device. MEAs are often fabricated from high modulus materials such as silicon, leaving devices vulnerable to brittle fracture and thus complicating device fabrication and handling. For this reason, polymer-based devices are being heavily investigated; however, their implementation is often difficult due to mechanical instability that requires insertion aids during implantation. In this study, we design and fabricate intracortical MEAs from a shape memory polymer (SMP) substrate that remains stiff at room temperature but softens to 20 MPa after implantation, therefore allowing the device to be implanted without aids. We demonstrate chronic recordings and electrochemical measurements for 16 weeks in rat cortex and show that the devices are robust to physical deformation, therefore making them advantageous for surgical implementation.
Collapse
Affiliation(s)
- Allison M. Stiller
- Department of Bioengineering, The University of Texas at Dallas, Richardson, TX 75080, USA; (J.O.U.); (J.L.); (B.A.); (W.E.V.); (B.J.B.); (J.J.P.)
| | - Joshua O. Usoro
- Department of Bioengineering, The University of Texas at Dallas, Richardson, TX 75080, USA; (J.O.U.); (J.L.); (B.A.); (W.E.V.); (B.J.B.); (J.J.P.)
| | - Jennifer Lawson
- Department of Bioengineering, The University of Texas at Dallas, Richardson, TX 75080, USA; (J.O.U.); (J.L.); (B.A.); (W.E.V.); (B.J.B.); (J.J.P.)
| | - Betsiti Araya
- Department of Bioengineering, The University of Texas at Dallas, Richardson, TX 75080, USA; (J.O.U.); (J.L.); (B.A.); (W.E.V.); (B.J.B.); (J.J.P.)
| | | | | | - Walter E. Voit
- Department of Bioengineering, The University of Texas at Dallas, Richardson, TX 75080, USA; (J.O.U.); (J.L.); (B.A.); (W.E.V.); (B.J.B.); (J.J.P.)
- Qualia, Inc., Dallas, TX 75252, USA;
- Department of Materials Science and Engineering, The University of Texas at Dallas, Richardson, TX 75080, USA
| | - Bryan J. Black
- Department of Bioengineering, The University of Texas at Dallas, Richardson, TX 75080, USA; (J.O.U.); (J.L.); (B.A.); (W.E.V.); (B.J.B.); (J.J.P.)
| | - Joseph J. Pancrazio
- Department of Bioengineering, The University of Texas at Dallas, Richardson, TX 75080, USA; (J.O.U.); (J.L.); (B.A.); (W.E.V.); (B.J.B.); (J.J.P.)
| |
Collapse
|
37
|
Mahajan S, Hermann JK, Bedell HW, Sharkins JA, Chen L, Chen K, Meade SM, Smith CS, Rayyan J, Feng H, Kim Y, Schiefer MA, Taylor DM, Capadona JR, Ereifej ES. Toward Standardization of Electrophysiology and Computational Tissue Strain in Rodent Intracortical Microelectrode Models. Front Bioeng Biotechnol 2020; 8:416. [PMID: 32457888 PMCID: PMC7225268 DOI: 10.3389/fbioe.2020.00416] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2019] [Accepted: 04/14/2020] [Indexed: 12/26/2022] Open
Abstract
Progress has been made in the field of neural interfacing using both mouse and rat models, yet standardization of these models' interchangeability has yet to be established. The mouse model allows for transgenic, optogenetic, and advanced imaging modalities which can be used to examine the biological impact and failure mechanisms associated with the neural implant itself. The ability to directly compare electrophysiological data between mouse and rat models is crucial for the development and assessment of neural interfaces. The most obvious difference in the two rodent models is size, which raises concern for the role of device-induced tissue strain. Strain exerted on brain tissue by implanted microelectrode arrays is hypothesized to affect long-term recording performance. Therefore, understanding any potential differences in tissue strain caused by differences in the implant to tissue size ratio is crucial for validating the interchangeability of rat and mouse models. Hence, this study is aimed at investigating the electrophysiological variances and predictive device-induced tissue strain. Rat and mouse electrophysiological recordings were collected from implanted animals for eight weeks. A finite element model was utilized to assess the tissue strain from implanted intracortical microelectrodes, taking into account the differences in the depth within the cortex, implantation depth, and electrode geometry between the two models. The rat model demonstrated a larger percentage of channels recording single unit activity and number of units recorded per channel at acute but not chronic time points, relative to the mouse model Additionally, the finite element models also revealed no predictive differences in tissue strain between the two rodent models. Collectively our results show that these two models are comparable after taking into consideration some recommendations to maintain uniform conditions for future studies where direct comparisons of electrophysiological and tissue strain data between the two animal models will be required.
Collapse
Affiliation(s)
- Shreya Mahajan
- Department of Electrical Engineering and Computer Science, University of Michigan, Ann Arbor, MI, United States
| | - John K. Hermann
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, United States
- Advanced Platform Technology Center, Louis Stokes Cleveland Veterans Affairs Medical Center, Cleveland, OH, United States
| | - Hillary W. Bedell
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, United States
- Advanced Platform Technology Center, Louis Stokes Cleveland Veterans Affairs Medical Center, Cleveland, OH, United States
| | - Jonah A. Sharkins
- Veteran Affairs Ann Arbor Healthcare System, Ann Arbor, MI, United States
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, United States
| | - Lei Chen
- Department of Mechanical Engineering, University of Michigan, Ann Arbor, MI, United States
| | - Keying Chen
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, United States
- Advanced Platform Technology Center, Louis Stokes Cleveland Veterans Affairs Medical Center, Cleveland, OH, United States
| | - Seth M. Meade
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, United States
- Advanced Platform Technology Center, Louis Stokes Cleveland Veterans Affairs Medical Center, Cleveland, OH, United States
| | - Cara S. Smith
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, United States
- Advanced Platform Technology Center, Louis Stokes Cleveland Veterans Affairs Medical Center, Cleveland, OH, United States
| | - Jacob Rayyan
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, United States
- Advanced Platform Technology Center, Louis Stokes Cleveland Veterans Affairs Medical Center, Cleveland, OH, United States
| | - He Feng
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, United States
- Advanced Platform Technology Center, Louis Stokes Cleveland Veterans Affairs Medical Center, Cleveland, OH, United States
| | - Youjoung Kim
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, United States
- Advanced Platform Technology Center, Louis Stokes Cleveland Veterans Affairs Medical Center, Cleveland, OH, United States
| | - Matthew A. Schiefer
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, United States
- Advanced Platform Technology Center, Louis Stokes Cleveland Veterans Affairs Medical Center, Cleveland, OH, United States
| | - Dawn M. Taylor
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, United States
- Advanced Platform Technology Center, Louis Stokes Cleveland Veterans Affairs Medical Center, Cleveland, OH, United States
- Department of Neuroscience, The Cleveland Clinic, Cleveland, OH, United States
| | - Jeffrey R. Capadona
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, United States
- Advanced Platform Technology Center, Louis Stokes Cleveland Veterans Affairs Medical Center, Cleveland, OH, United States
| | - Evon S. Ereifej
- Advanced Platform Technology Center, Louis Stokes Cleveland Veterans Affairs Medical Center, Cleveland, OH, United States
- Veteran Affairs Ann Arbor Healthcare System, Ann Arbor, MI, United States
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, United States
- Department of Neurology, University of Michigan, Ann Arbor, MI, United States
| |
Collapse
|
38
|
Parashar K, Prajapati D, McIntyre R, Kandasubramanian B. Advancements in Biological Neural Interfaces Using Conducting Polymers: A Review. Ind Eng Chem Res 2020. [DOI: 10.1021/acs.iecr.0c00174] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Affiliation(s)
- Kashish Parashar
- Nanofabrication and Characterization Lab, Centre for Converging Technologies, University of Rajasthan, JLN Marg, Jaipur-302004, India
| | - Deepak Prajapati
- Material Science and Engineering, Indian Institute of Technology, Gandhinagar, Gujarat 382355, India
| | | | - Balasubramanian Kandasubramanian
- Nano Surface Texturing Lab, Dept. of Metallurgical and Materials Engineering, Defence Institute of Advanced Technology (DIAT), Ministry of Defence, DRDO, Girinagar, Pune-411025, India
| |
Collapse
|
39
|
Jung YH, Kim JU, Lee JS, Shin JH, Jung W, Ok J, Kim TI. Injectable Biomedical Devices for Sensing and Stimulating Internal Body Organs. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2020; 32:e1907478. [PMID: 32104960 DOI: 10.1002/adma.201907478] [Citation(s) in RCA: 28] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/14/2019] [Revised: 01/15/2020] [Indexed: 06/10/2023]
Abstract
The rapid pace of progress in implantable electronics driven by novel technology has created devices with unconventional designs and features to reduce invasiveness and establish new sensing and stimulating techniques. Among the designs, injectable forms of biomedical electronics are explored for accurate and safe targeting of deep-seated body organs. Here, the classes of biomedical electronics and tools that have high aspect ratio structures designed to be injected or inserted into internal organs for minimally invasive monitoring and therapy are reviewed. Compared with devices in bulky or planar formats, the long shaft-like forms of implantable devices are easily placed in the organs with minimized outward protrusions via injection or insertion processes. Adding flexibility to the devices also enables effortless insertions through complex biological cavities, such as the cochlea, and enhances chronic reliability by complying with natural body movements, such as the heartbeat. Diverse types of such injectable implants developed for different organs are reviewed and the electronic, optoelectronic, piezoelectric, and microfluidic devices that enable stimulations and measurements of site-specific regions in the body are discussed. Noninvasive penetration strategies to deliver the miniscule devices are also considered. Finally, the challenges and future directions associated with deep body biomedical electronics are explained.
Collapse
Affiliation(s)
- Yei Hwan Jung
- School of Chemical Engineering, Sungkyunkwan University (SKKU), Suwon, 16419, Republic of Korea
| | - Jong Uk Kim
- School of Chemical Engineering, Sungkyunkwan University (SKKU), Suwon, 16419, Republic of Korea
| | - Ju Seung Lee
- School of Chemical Engineering, Sungkyunkwan University (SKKU), Suwon, 16419, Republic of Korea
| | - Joo Hwan Shin
- School of Chemical Engineering, Sungkyunkwan University (SKKU), Suwon, 16419, Republic of Korea
| | - Woojin Jung
- School of Chemical Engineering, Sungkyunkwan University (SKKU), Suwon, 16419, Republic of Korea
| | - Jehyung Ok
- School of Chemical Engineering, Sungkyunkwan University (SKKU), Suwon, 16419, Republic of Korea
| | - Tae-Il Kim
- School of Chemical Engineering, Department of Biomedical Engineering, and Biomedical Institute for Convergence at SKKU (BICS), Sungkyunkwan University (SKKU), Suwon, 16419, Republic of Korea
| |
Collapse
|
40
|
Rochford AE, Carnicer-Lombarte A, Curto VF, Malliaras GG, Barone DG. When Bio Meets Technology: Biohybrid Neural Interfaces. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2020; 32:e1903182. [PMID: 31517403 DOI: 10.1002/adma.201903182] [Citation(s) in RCA: 45] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/18/2019] [Revised: 07/06/2019] [Indexed: 06/10/2023]
Abstract
The development of electronics capable of interfacing with the nervous system is a rapidly advancing field with applications in basic science and clinical translation. Devices containing arrays of electrodes can be used in the study of cells grown in culture or can be implanted into damaged or dysfunctional tissue to restore normal function. While devices are typically designed and used exclusively for one of these two purposes, there have been increasing efforts in developing implantable electrode arrays capable of housing cultured cells, referred to as biohybrid implants. Once implanted, the cells within these implants integrate into the tissue, serving as a mediator of the electrode-tissue interface. This biological component offers unique advantages to these implant designs, providing better tissue integration and potentially long-term stability. Herein, an overview of current research into biohybrid devices, as well as the historical background that led to their development are provided, based on the host anatomical location for which they are designed (CNS, PNS, or special senses). Finally, a summary of the key challenges of this technology and potential future research directions are presented.
Collapse
Affiliation(s)
- Amy E Rochford
- Electrical Engineering Division, Department of Engineering, University of Cambridge, Cambridge, CB3 0FA, UK
| | | | - Vincenzo F Curto
- Electrical Engineering Division, Department of Engineering, University of Cambridge, Cambridge, CB3 0FA, UK
| | - George G Malliaras
- Electrical Engineering Division, Department of Engineering, University of Cambridge, Cambridge, CB3 0FA, UK
| | - Damiano G Barone
- Electrical Engineering Division, Department of Engineering, University of Cambridge, Cambridge, CB3 0FA, UK
- Department of Clinical Neurosciences, University of Cambridge, Cambridge, CB2 0QQ, UK
| |
Collapse
|
41
|
Das R, Moradi F, Heidari H. Biointegrated and Wirelessly Powered Implantable Brain Devices: A Review. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2020; 14:343-358. [PMID: 31944987 DOI: 10.1109/tbcas.2020.2966920] [Citation(s) in RCA: 40] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/07/2023]
|
42
|
Abalymov A, Parakhonskiy B, Skirtach AG. Polymer- and Hybrid-Based Biomaterials for Interstitial, Connective, Vascular, Nerve, Visceral and Musculoskeletal Tissue Engineering. Polymers (Basel) 2020; 12:E620. [PMID: 32182751 PMCID: PMC7182904 DOI: 10.3390/polym12030620] [Citation(s) in RCA: 42] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2019] [Revised: 02/19/2020] [Accepted: 03/03/2020] [Indexed: 12/11/2022] Open
Abstract
In this review, materials based on polymers and hybrids possessing both organic and inorganic contents for repairing or facilitating cell growth in tissue engineering are discussed. Pure polymer based biomaterials are predominantly used to target soft tissues. Stipulated by possibilities of tuning the composition and concentration of their inorganic content, hybrid materials allow to mimic properties of various types of harder tissues. That leads to the concept of "one-matches-all" referring to materials possessing the same polymeric base, but different inorganic content to enable tissue growth and repair, proliferation of cells, and the formation of the ECM (extra cellular matrix). Furthermore, adding drug delivery carriers to coatings and scaffolds designed with such materials brings additional functionality by encapsulating active molecules, antibacterial agents, and growth factors. We discuss here materials and methods of their assembly from a general perspective together with their applications in various tissue engineering sub-areas: interstitial, connective, vascular, nervous, visceral and musculoskeletal tissues. The overall aims of this review are two-fold: (a) to describe the needs and opportunities in the field of bio-medicine, which should be useful for material scientists, and (b) to present capabilities and resources available in the area of materials, which should be of interest for biologists and medical doctors.
Collapse
Affiliation(s)
- Anatolii Abalymov
- Department of Biotechnology, Faculty of Bioscience Engineering, Ghent University, 9000 Ghent, Belgium
| | | | - Andre G. Skirtach
- Department of Biotechnology, Faculty of Bioscience Engineering, Ghent University, 9000 Ghent, Belgium
| |
Collapse
|
43
|
Sung C, Jeon W, Nam KS, Kim Y, Butt H, Park S. Multimaterial and multifunctional neural interfaces: from surface-type and implantable electrodes to fiber-based devices. J Mater Chem B 2020; 8:6624-6666. [DOI: 10.1039/d0tb00872a] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Development of neural interfaces from surface electrodes to fibers with various type, functionality, and materials.
Collapse
Affiliation(s)
- Changhoon Sung
- Department of Bio and Brain Engineering
- Korea Advanced Institute of Science and Technology (KAIST)
- Daejeon 34141
- Republic of Korea
| | - Woojin Jeon
- Department of Bio and Brain Engineering
- Korea Advanced Institute of Science and Technology (KAIST)
- Daejeon 34141
- Republic of Korea
| | - Kum Seok Nam
- School of Electrical Engineering
- Korea Advanced Institute of Science and Technology (KAIST)
- Daejeon 34141
- Republic of Korea
| | - Yeji Kim
- Department of Bio and Brain Engineering
- Korea Advanced Institute of Science and Technology (KAIST)
- Daejeon 34141
- Republic of Korea
| | - Haider Butt
- Department of Mechanical Engineering
- Khalifa University
- Abu Dhabi 127788
- United Arab Emirates
| | - Seongjun Park
- Department of Bio and Brain Engineering
- Korea Advanced Institute of Science and Technology (KAIST)
- Daejeon 34141
- Republic of Korea
- KAIST Institute for Health Science and Technology (KIHST)
| |
Collapse
|
44
|
Qu J, Garabedian N, Burris DL, Martin DC. Durability of Poly(3,4-ethylenedioxythiophene) (PEDOT) films on metallic substrates for bioelectronics and the dominant role of relative shear strength. J Mech Behav Biomed Mater 2019; 100:103376. [DOI: 10.1016/j.jmbbm.2019.103376] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2019] [Revised: 07/19/2019] [Accepted: 07/30/2019] [Indexed: 01/07/2023]
|
45
|
Cutrone A, Micera S. Implantable Neural Interfaces and Wearable Tactile Systems for Bidirectional Neuroprosthetics Systems. Adv Healthc Mater 2019; 8:e1801345. [PMID: 31763784 DOI: 10.1002/adhm.201801345] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2018] [Revised: 03/22/2019] [Indexed: 12/12/2022]
Abstract
Neuroprosthetics and neuromodulation represent a promising field for several related applications in the central and peripheral nervous system, such as the treatment of neurological disorders, the control of external robotic devices, and the restoration of lost tactile functions. These actions are allowed by the neural interface, a miniaturized implantable device that most commonly exploits electrical energy to fulfill these operations. A neural interface must be biocompatible, stable over time, low invasive, and highly selective; the challenge is to develop a safe, compact, and reliable tool for clinical applications. In case of anatomical impairments, neuroprosthetics is bound to the need of exploring the surrounding environment by fast-responsive and highly sensitive artificial tactile sensors that mimic the natural sense of touch. Tactile sensors and neural interfaces are closely interconnected since the readouts from the first are required to convey information to the neural implantable apparatus. The role of these devices is pivotal hence technical improvements are essential to ensure a secure system to be eventually adopted in daily life. This review highlights the fundamental criteria for the design and microfabrication of neural interfaces and artificial tactile sensors, their use in clinical applications, and future enhancements for the release of a second generation of devices.
Collapse
Affiliation(s)
- Annarita Cutrone
- The Biorobotics Institute, Viale Rinaldo Piaggio 34, 56025, Pontedera, Italy
| | - Silvestro Micera
- The Biorobotics Institute, Viale Rinaldo Piaggio 34, 56025, Pontedera, Italy
- Bertarelli Foundation Chair in Translational Neuroengineering, Centre for Neuroprosthetics and Institute of Bioengineering, School of Engineering, Ecole Polytechnique Federale de Lausanne (EPFL), Lausanne, CH-1202, Switzerland
| |
Collapse
|
46
|
Yang JC, Mun J, Kwon SY, Park S, Bao Z, Park S. Electronic Skin: Recent Progress and Future Prospects for Skin-Attachable Devices for Health Monitoring, Robotics, and Prosthetics. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2019; 31:e1904765. [PMID: 31538370 DOI: 10.1002/adma.201904765] [Citation(s) in RCA: 488] [Impact Index Per Article: 97.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/24/2019] [Revised: 08/26/2019] [Indexed: 05/17/2023]
Abstract
Recent progress in electronic skin or e-skin research is broadly reviewed, focusing on technologies needed in three main applications: skin-attachable electronics, robotics, and prosthetics. First, since e-skin will be exposed to prolonged stresses of various kinds and needs to be conformally adhered to irregularly shaped surfaces, materials with intrinsic stretchability and self-healing properties are of great importance. Second, tactile sensing capability such as the detection of pressure, strain, slip, force vector, and temperature are important for health monitoring in skin attachable devices, and to enable object manipulation and detection of surrounding environment for robotics and prosthetics. For skin attachable devices, chemical and electrophysiological sensing and wireless signal communication are of high significance to fully gauge the state of health of users and to ensure user comfort. For robotics and prosthetics, large-area integration on 3D surfaces in a facile and scalable manner is critical. Furthermore, new signal processing strategies using neuromorphic devices are needed to efficiently process tactile information in a parallel and low power manner. For prosthetics, neural interfacing electrodes are of high importance. These topics are discussed, focusing on progress, current challenges, and future prospects.
Collapse
Affiliation(s)
- Jun Chang Yang
- Department of Materials Science and Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon, 34141, Republic of Korea
| | - Jaewan Mun
- Department of Chemical Engineering, Stanford University, Stanford, CA, 94305-5025, USA
| | - Se Young Kwon
- Department of Materials Science and Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon, 34141, Republic of Korea
| | - Seongjun Park
- Department of Materials Science and Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon, 34141, Republic of Korea
- Korea Advanced Institute of Science and Technology (KAIST), Daejeon, 34141, Republic of Korea
| | - Zhenan Bao
- Department of Chemical Engineering, Stanford University, Stanford, CA, 94305-5025, USA
| | - Steve Park
- Department of Bio and Brain Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon, 34141, Republic of Korea
| |
Collapse
|
47
|
Zhang Y, Castro DC, Han Y, Wu Y, Guo H, Weng Z, Xue Y, Ausra J, Wang X, Li R, Wu G, Vázquez-Guardado A, Xie Y, Xie Z, Ostojich D, Peng D, Sun R, Wang B, Yu Y, Leshock JP, Qu S, Su CJ, Shen W, Hang T, Banks A, Huang Y, Radulovic J, Gutruf P, Bruchas MR, Rogers JA. Battery-free, lightweight, injectable microsystem for in vivo wireless pharmacology and optogenetics. Proc Natl Acad Sci U S A 2019; 116:21427-21437. [PMID: 31601737 PMCID: PMC6815115 DOI: 10.1073/pnas.1909850116] [Citation(s) in RCA: 84] [Impact Index Per Article: 16.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022] Open
Abstract
Pharmacology and optogenetics are widely used in neuroscience research to study the central and peripheral nervous systems. While both approaches allow for sophisticated studies of neural circuitry, continued advances are, in part, hampered by technology limitations associated with requirements for physical tethers that connect external equipment to rigid probes inserted into delicate regions of the brain. The results can lead to tissue damage and alterations in behavioral tasks and natural movements, with additional difficulties in use for studies that involve social interactions and/or motions in complex 3-dimensional environments. These disadvantages are particularly pronounced in research that demands combined optogenetic and pharmacological functions in a single experiment. Here, we present a lightweight, wireless, battery-free injectable microsystem that combines soft microfluidic and microscale inorganic light-emitting diode probes for programmable pharmacology and optogenetics, designed to offer the features of drug refillability and adjustable flow rates, together with programmable control over the temporal profiles. The technology has potential for large-scale manufacturing and broad distribution to the neuroscience community, with capabilities in targeting specific neuronal populations in freely moving animals. In addition, the same platform can easily be adapted for a wide range of other types of passive or active electronic functions, including electrical stimulation.
Collapse
Affiliation(s)
- Yi Zhang
- Department of Biomedical, Biological, and Chemical Engineering, University of Missouri, Columbia, MO 65211
- Department of Materials Science and Engineering, Northwestern University, Evanston, IL 60208
| | - Daniel C Castro
- Department of Anesthesiology and Pain Medicine, University of Washington, Seattle, WA 98195
| | - Yuan Han
- Department of Psychiatry and Behavioral Sciences, Northwestern University, Chicago, IL 60611
- Department of Anesthesiology, Eye & ENT Hospital, Fudan University, 200031 Shanghai, China
- Jiangsu Province Key Laboratory of Anesthesiology, Xuzhou Medical University, 221004 Xuzhou, China
| | - Yixin Wu
- Department of Materials Science and Engineering, Northwestern University, Evanston, IL 60208
| | - Hexia Guo
- Department of Materials Science and Engineering, Northwestern University, Evanston, IL 60208
| | - Zhengyan Weng
- Department of Biomedical, Biological, and Chemical Engineering, University of Missouri, Columbia, MO 65211
| | - Yeguang Xue
- Department of Materials Science and Engineering, Northwestern University, Evanston, IL 60208
- Department of Civil and Environmental Engineering, Northwestern University, Evanston, IL 60208
- Department of Mechanical Engineering, Northwestern University, Evanston, IL 60208
| | - Jokubas Ausra
- Biomedical Engineering, College of Engineering, The University of Arizona, Tucson, AZ 85721
| | - Xueju Wang
- Department of Mechanical and Aerospace Engineering, University of Missouri, Columbia, MO 65211
| | - Rui Li
- State Key Laboratory of Structural Analysis for Industrial Equipment, Department of Engineering Mechanics, Dalian University of Technology, 116024 Dalian, China
- International Research Center for Computational Mechanics, Dalian University of Technology, 116024 Dalian, China
| | - Guangfu Wu
- Department of Biomedical, Biological, and Chemical Engineering, University of Missouri, Columbia, MO 65211
| | | | - Yiwen Xie
- Department of Materials Science and Engineering, Northwestern University, Evanston, IL 60208
| | - Zhaoqian Xie
- Department of Civil and Environmental Engineering, Northwestern University, Evanston, IL 60208
- Department of Mechanical Engineering, Northwestern University, Evanston, IL 60208
- State Key Laboratory of Structural Analysis for Industrial Equipment, Department of Engineering Mechanics, Dalian University of Technology, 116024 Dalian, China
| | - Diana Ostojich
- Department of Materials Science and Engineering, Northwestern University, Evanston, IL 60208
| | - Dongsheng Peng
- College of Optoelectronic Engineering, Shenzhen University, 518060 Shenzhen, China
| | - Rujie Sun
- Bristol Composites Institute, University of Bristol, BS8 1TR Bristol, United Kingdom
| | - Binbin Wang
- Department of Civil and Environmental Engineering, University of Missouri, Columbia, MO 65211
| | | | - John P Leshock
- Department of Materials Science and Engineering, Northwestern University, Evanston, IL 60208
| | - Subing Qu
- Department of Materials Science and Engineering, Materials Research Laboratory, University of Illinois at Urbana-Champaign, Urbana, IL 61801
| | - Chun-Ju Su
- Department of Materials Science and Engineering, Northwestern University, Evanston, IL 60208
| | - Wen Shen
- Department of Mechanical and Aerospace Engineering, University of Texas at Arlington, Arlington, TX 76019
| | - Tao Hang
- School of Materials Science and Engineering, Shanghai Jiao Tong University, 200240 Shanghai, China
| | - Anthony Banks
- Department of Materials Science and Engineering, Northwestern University, Evanston, IL 60208
| | - Yonggang Huang
- Department of Materials Science and Engineering, Northwestern University, Evanston, IL 60208
- Department of Civil and Environmental Engineering, Northwestern University, Evanston, IL 60208
- Department of Mechanical Engineering, Northwestern University, Evanston, IL 60208
- Center for Bio-Integrated Electronics, Northwestern University, Evanston, IL 60208
| | - Jelena Radulovic
- Department of Psychiatry and Behavioral Sciences, Northwestern University, Chicago, IL 60611
| | - Philipp Gutruf
- Biomedical Engineering, College of Engineering, The University of Arizona, Tucson, AZ 85721;
| | - Michael R Bruchas
- Department of Anesthesiology and Pain Medicine, University of Washington, Seattle, WA 98195;
- Center for Neurobiology of Addiction, Pain, and Emotion, University of Washington, Seattle, WA 98195
- Department of Pharmacology, University of Washington, Seattle, WA 98195
| | - John A Rogers
- Department of Materials Science and Engineering, Northwestern University, Evanston, IL 60208;
- Center for Bio-Integrated Electronics, Northwestern University, Evanston, IL 60208
- Simpson Querrey Institute, Northwestern University, Chicago, IL 60611
- Department of Biomedical Engineering, Northwestern University, Evanston, IL 60208
- Department of Chemistry, Northwestern University, Evanston, IL 60208
- Department of Neurological Surgery, Feinberg School of Medicine, Northwestern University, Chicago, IL 60611
| |
Collapse
|
48
|
Ferguson M, Sharma D, Ross D, Zhao F. A Critical Review of Microelectrode Arrays and Strategies for Improving Neural Interfaces. Adv Healthc Mater 2019; 8:e1900558. [PMID: 31464094 PMCID: PMC6786932 DOI: 10.1002/adhm.201900558] [Citation(s) in RCA: 37] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2019] [Revised: 07/25/2019] [Indexed: 12/19/2022]
Abstract
Though neural interface systems (NISs) can provide a potential solution for mitigating the effects of limb loss and central nervous system damage, the microelectrode array (MEA) component of NISs remains a significant limiting factor to their widespread clinical applications. Several strategies can be applied to MEA designs to increase their biocompatibility. Herein, an overview of NISs and their applications is provided, along with a detailed discussion of strategies for alleviating the foreign body response (FBR) and abnormalities seen at the interface of MEAs and the brain tissue following MEA implantation. Various surface modifications, including natural/synthetic surface coatings, hydrogels, and topography alterations, have shown to be highly successful in improving neural cell adhesion, reducing gliosis, and increasing MEA longevity. Different MEA surface geometries, such as those seen in the Utah and Michigan arrays, can help alleviate the resultant FBR by reducing insertion damage, while providing new avenues for improving MEA recording performance and resolution. Increasing overall flexibility of MEAs as well as reducing their stiffness is also shown to reduce MEA induced micromotion along with FBR severity. By combining multiple different properties into a single MEA, the severity and duration of an FBR postimplantation can be reduced substantially.
Collapse
Affiliation(s)
- Morgan Ferguson
- Department of Biomedical Engineering, Michigan Technological University, 1400 Townsend Dr., Houghton, MI 49931
| | - Dhavan Sharma
- Department of Biomedical Engineering, Michigan Technological University, 1400 Townsend Dr., Houghton, MI 49931
| | - David Ross
- Department of Biomedical Engineering, Michigan Technological University, 1400 Townsend Dr., Houghton, MI 49931
| | - Feng Zhao
- Department of Biomedical Engineering, Michigan Technological University, 1400 Townsend Dr., Houghton, MI 49931
| |
Collapse
|
49
|
WANG JF, TIAN HH, FANG Y. Implantable and Flexible Electronics for In vivo Brain Activity Recordings. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY 2019. [DOI: 10.1016/s1872-2040(19)61192-8] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
50
|
Abstract
Neural recording electrode technologies have contributed considerably to neuroscience by enabling the extracellular detection of low-frequency local field potential oscillations and high-frequency action potentials of single units. Nevertheless, several long-standing limitations exist, including low multiplexity, deleterious chronic immune responses and long-term recording instability. Driven by initiatives encouraging the generation of novel neurotechnologies and the maturation of technologies to fabricate high-density electronics, novel electrode technologies are emerging. Here, we provide an overview of recently developed neural recording electrode technologies with high spatial integration, long-term stability and multiple functionalities. We describe how these emergent neurotechnologies can approach the ultimate goal of illuminating chronic brain activity with minimal disruption of the neural environment, thereby providing unprecedented opportunities for neuroscience research in the future.
Collapse
Affiliation(s)
- Guosong Hong
- Department of Chemistry and Chemical Biology, Harvard University, Cambridge, MA, USA
- Department of Materials Science and Engineering, Stanford University, Stanford, CA, USA
- Wu Tsai Neurosciences Institute, Stanford University, Stanford, CA, USA
| | - Charles M Lieber
- Department of Chemistry and Chemical Biology, Harvard University, Cambridge, MA, USA.
- Center for Brain Science, Harvard University, Cambridge, MA, USA.
- John A. Paulson School of Engineering and Applied Sciences, Harvard University, Cambridge, MA, USA.
| |
Collapse
|