1
|
Titt U, Pera E, Gillin MT. Monte Carlo Simulations of Neutron Ambient Dose Equivalent in a Novel Proton Therapy Facility Design. Int J Part Ther 2020; 6:29-37. [PMID: 32582817 PMCID: PMC7302728 DOI: 10.14338/ijpt-19-00071.1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2019] [Accepted: 01/22/2020] [Indexed: 11/21/2022] Open
Abstract
Purpose The neutron shielding properties of the concrete structures of a proposed proton therapy facility were evaluated with help of the Monte Carlo technique. The planned facility's design omits the typical maze-structured entrances to the treatment rooms to facilitate more efficient access and, instead, proposes the use of massive concrete/steel doors. Furthermore, straight conduits in the treatment room walls were used in the design of the facility, necessitating a detailed investigation of the neutron radiation outside the rooms to determine if the design can be applied without violating existing radiation protection regulations. This study was performed to investigate whether the operation of a proton therapy unit using such a facility design will be in compliance with radiation protection requirements. Methods A detailed model of the planned proton therapy expansion project of the University of Texas, M. D. Anderson Cancer Center in Houston, Texas, was produced to simulate secondary neutron production from clinical proton beams using the MCNPX Monte Carlo radiation transport code. Neutron spectral fluences were collected at locations of interest and converted to ambient dose equivalents using an in-house code based on fluence to dose-conversion factors provided by the International Commission on Radiological Protection. Results and Conclusions At all investigated locations of interest, the ambient dose equivalent values were below the occupational dose limits and the dose limits for individual members of the public. The impact of straight conduits was negligible because their location and orientation were such that no line of sight to the neutron sources (ie, the isocenter locations) was established. Finally, the treatment room doors were specially designed to provide spatial efficiency and, compared with traditional maze designs, showed that while it would be possible to achieve a lower neutron ambient dose equivalent with a maze, the increased spatial (and financial) requirements may offset this advantage.
Collapse
Affiliation(s)
- Uwe Titt
- University of Texas, M. D. Anderson Cancer Center, Houston, TX, USA
| | - Enzo Pera
- University of Texas, M. D. Anderson Cancer Center, Houston, TX, USA
| | - Michael T Gillin
- University of Texas, M. D. Anderson Cancer Center, Houston, TX, USA
| |
Collapse
|
2
|
Gallagher KJ, Taddei PJ. Independent application of an analytical model for secondary neutron equivalent dose produced in a passive-scattering proton therapy treatment unit. Phys Med Biol 2018; 63:15NT04. [PMID: 29978833 DOI: 10.1088/1361-6560/aad1bc] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
The purpose of this study was to independently apply an analytical model for equivalent dose from neutrons produced in a passive-scattering proton therapy treatment unit, H. To accomplish this objective, we applied the previously-published model to treatment plans of two pediatric patients. Their model accounted for neutrons generated by mono-energetic proton beams stopping in a closed aperture. To implement their model to a clinical setting, we adjusted it to account for the area of a collimating aperture, energy modulation, air gap between the treatment unit and patient, and radiation weighting factor. We used the adjusted model to estimate H per prescribed proton absorbed dose, D Rx , for the passive-scattering proton therapy beams of two children, a 9-year-old girl and 10-year-old boy, who each received intracranial boost fields as part of their treatment. In organs and tissues at risk for radiation-induced subsequent malignant neoplasms, T, we calculated the mass-averaged H, H T , per D Rx . Finally, we compared H T /D Rx values to those of previously-published Monte Carlo (MC) simulations of these patients' fields. H T /D Rx values of the adjusted model deviated from the MC result for each organ on average by 20.8 ± 10.0% and 44.2 ± 17.6% for the girl and boy, respectively. The adjusted model underestimated the MC result in all T of each patient, with the exception of the girl's bladder, for which the adjusted model overestimated H T /D Rx by 3.1%. The adjusted model provided a better estimate of H T /D Rx than the unadjusted model. That is, between the two models, the adjusted model reduced the deviation from the MC result by approximately 37.0% and 46.7% for the girl and boy, respectively. We found that the previously-published analytical model, combined with adjustment factors to enhance its clinical applicability, predicted H T /D Rx in out-of-field organs and tissues at risk for subsequent malignant neoplasms with acceptable accuracy. This independent application demonstrated that the analytical model may be useful broadly for clinicians and researchers to calculate equivalent dose from neutrons produced externally to the patient in passive-scattering proton therapy.
Collapse
Affiliation(s)
- Kyle J Gallagher
- Oregon Health and Science University, Portland, OR, United States of America. Oregon State University, Corvallis, OR, United States of America
| | | |
Collapse
|
3
|
Ambient neutron dose equivalent during proton therapy using wobbling scanning system: Measurements and calculations. Radiat Phys Chem Oxf Engl 1993 2017. [DOI: 10.1016/j.radphyschem.2017.01.025] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
4
|
Chapman JW, Knutson NC, Fontenot JD, Newhauser WD, Hogstrom KR. Evaluating the accuracy of a three-term pencil beam algorithm in heterogeneous media. Phys Med Biol 2017; 62:1172-1191. [PMID: 28092635 DOI: 10.1088/1361-6560/aa51aa] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
The goal of this work was to evaluate the accuracy of our in-house analytical dose calculation code against MCNPX data in heterogeneous phantoms. The analytical model utilizes a pencil beam model based on Fermi-Eyges theory to account for multiple Coulomb scattering and a least-squares fit to Monte Carlo data to account for nonelastic nuclear interactions as well as any remaining, uncharacterized scatter (the 'nuclear halo'). The model characterized dose accurately (up to 1% of maximum dose in broad fields (4 × 4 cm2 and 10 × 10 cm2) and up to 0.01% in a narrow field (0.1 × 0.1 cm2) fit to MCNPX data). The accuracy of the model was benchmarked in three types of stylized phantoms: (1) homogeneous, (2) laterally infinite slab heterogeneities, and (3) laterally finite slab heterogeneities. Results from homogeneous phantoms and laterally infinite slab heterogeneities showed high levels of accuracy (>98% of points within 2% or 0.1 cm distance-to-agreement (DTA)). However, because range straggling and secondary particle production were not included in our model, central-axis dose differences of 2-4% were observed in laterally infinite slab heterogeneities when compared to Monte Carlo dose. In the presence of laterally finite slab heterogeneities, the analytical model resulted in lower pass rates (>96% of points within 2% or 0.1 cm DTA), which was attributed to the use of the central-axis approximation.
Collapse
Affiliation(s)
- J W Chapman
- Department of Physics and Astronomy, Louisiana State University and Agricultural and Mechanical College, 202 Nicholson Hall, Tower Drive, Baton Rouge, LA 70803, USA
| | | | | | | | | |
Collapse
|
5
|
Newhauser WD, de Gonzalez AB, Schulte R, Lee C. A Review of Radiotherapy-Induced Late Effects Research after Advanced Technology Treatments. Front Oncol 2016; 6:13. [PMID: 26904500 PMCID: PMC4748041 DOI: 10.3389/fonc.2016.00013] [Citation(s) in RCA: 51] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2015] [Accepted: 01/12/2016] [Indexed: 01/01/2023] Open
Abstract
The number of incident cancers and long-term cancer survivors is expected to increase substantially for at least a decade. Advanced technology radiotherapies, e.g., using beams of protons and photons, offer dosimetric advantages that theoretically yield better outcomes. In general, evidence from controlled clinical trials and epidemiology studies are lacking. To conduct these studies, new research methods and infrastructure will be needed. In the paper, we review several key research methods of relevance to late effects after advanced technology proton-beam and photon-beam radiotherapies. In particular, we focus on the determination of exposures to therapeutic and stray radiation and related uncertainties, with discussion of recent advances in exposure calculation methods, uncertainties, in silico studies, computing infrastructure, electronic medical records, and risk visualization. We identify six key areas of methodology and infrastructure that will be needed to conduct future outcome studies of radiation late effects.
Collapse
Affiliation(s)
- Wayne D. Newhauser
- Department of Physics and Astronomy, Louisiana State University, Baton Rouge, LA, USA
- Department of Physics, Mary Bird Perkins Cancer Center, Baton Rouge, LA, USA
| | | | - Reinhard Schulte
- Department of Basic Sciences, Loma Linda University Medical Center, Loma Linda, CA, USA
| | - Choonsik Lee
- Radiation Epidemiology Branch, National Institutes of Health, Rockville, MD, USA
| |
Collapse
|
6
|
Abstract
The physics of proton therapy has advanced considerably since it was proposed in 1946. Today analytical equations and numerical simulation methods are available to predict and characterize many aspects of proton therapy. This article reviews the basic aspects of the physics of proton therapy, including proton interaction mechanisms, proton transport calculations, the determination of dose from therapeutic and stray radiations, and shielding design. The article discusses underlying processes as well as selected practical experimental and theoretical methods. We conclude by briefly speculating on possible future areas of research of relevance to the physics of proton therapy.
Collapse
Affiliation(s)
- Wayne D Newhauser
- Medical Physics Program, Department of Physics and Astronomy, Louisiana State University, 202 Nicholson Hall, Baton Rouge, LA, 70803, USA
- Mary Bird Perkins Cancer Center, 4950 Essen Lane, Baton Rouge, LA, 70809, USA
| | - Rui Zhang
- Medical Physics Program, Department of Physics and Astronomy, Louisiana State University, 202 Nicholson Hall, Baton Rouge, LA, 70803, USA
- Mary Bird Perkins Cancer Center, 4950 Essen Lane, Baton Rouge, LA, 70809, USA
| |
Collapse
|
7
|
Implementation of an analytical model for leakage neutron equivalent dose in a proton radiotherapy planning system. Cancers (Basel) 2015; 7:427-38. [PMID: 25768061 PMCID: PMC4381266 DOI: 10.3390/cancers7010427] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2014] [Revised: 02/12/2015] [Accepted: 03/02/2015] [Indexed: 01/05/2023] Open
Abstract
Equivalent dose from neutrons produced during proton radiotherapy increases the predicted risk of radiogenic late effects. However, out-of-field neutron dose is not taken into account by commercial proton radiotherapy treatment planning systems. The purpose of this study was to demonstrate the feasibility of implementing an analytical model to calculate leakage neutron equivalent dose in a treatment planning system. Passive scattering proton treatment plans were created for a water phantom and for a patient. For both the phantom and patient, the neutron equivalent doses were small but non-negligible and extended far beyond the therapeutic field. The time required for neutron equivalent dose calculation was 1.6 times longer than that required for proton dose calculation, with a total calculation time of less than 1 h on one processor for both treatment plans. Our results demonstrate that it is feasible to predict neutron equivalent dose distributions using an analytical dose algorithm for individual patients with irregular surfaces and internal tissue heterogeneities. Eventually, personalized estimates of neutron equivalent dose to organs far from the treatment field may guide clinicians to create treatment plans that reduce the risk of late effects.
Collapse
|
8
|
Jia SB, Hadizadeh MH, Mowlavi AA, Loushab ME. Evaluation of energy deposition and secondary particle production in proton therapy of brain using a slab head phantom. Rep Pract Oncol Radiother 2014; 19:376-84. [PMID: 25337410 PMCID: PMC4201772 DOI: 10.1016/j.rpor.2014.04.008] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2013] [Revised: 03/24/2014] [Accepted: 04/07/2014] [Indexed: 01/14/2023] Open
Abstract
AIM Evaluation of energy deposition of protons in human brain and calculation of the secondary neutrons and photons produced by protons in proton therapy. BACKGROUND Radiation therapy is one of the main methods of treating localized cancer tumors. The use of high energy proton beam in radiotherapy was proposed almost 60 years ago. In recent years, there has been a revival of interest in this subject in the context of radiation therapy. High energy protons suffer little angular deflection and have a well-defined penetration range, with a sharp increase in the energy loss at the end of their trajectories, namely the Bragg peak. MATERIALS AND METHODS A slab head phantom was used for the purpose of simulating proton therapy in brain tissue. In this study simulation was carried out using the Monte Carlo MCNPX code. RESULTS By using mono energetic proton pencil beams, energy depositions in tissues, especially inside the brain, as well as estimating the neutron and photon production as a result of proton interactions in the body, together with their energy spectra, were calculated or obtained. The amount of energy escaped from the head by secondary neutrons and photons was determined. CONCLUSIONS It was found that for high energy proton beams the amount of escaped energy by neutrons is almost 10 times larger than that by photons. We estimated that at 110 MeV beam energy, the overall proton energy "leaked" from the head by secondary photons and neutrons to be around 1%.
Collapse
Affiliation(s)
- Sayyed Bijan Jia
- Physics Department, School of Sciences, Ferdowsi University of Mashhad, P.O. Box 91775-1436, Mashhad, Iran
| | - Mohammad Hadi Hadizadeh
- Physics Department, School of Sciences, Ferdowsi University of Mashhad, P.O. Box 91775-1436, Mashhad, Iran
| | - Ali Asghar Mowlavi
- Physics Department, School of Sciences, Hakim Sabzevari University, P.O. Box 397, Sabzevar, Iran
| | - Mahdy Ebrahimi Loushab
- Physics Department, School of Sciences, Ferdowsi University of Mashhad, P.O. Box 91775-1436, Mashhad, Iran
| |
Collapse
|
9
|
Sayah R, Farah J, Donadille L, Hérault J, Delacroix S, De Marzi L, De Oliveira A, Vabre I, Stichelbaut F, Lee C, Bolch WE, Clairand I. Secondary neutron doses received by paediatric patients during intracranial proton therapy treatments. JOURNAL OF RADIOLOGICAL PROTECTION : OFFICIAL JOURNAL OF THE SOCIETY FOR RADIOLOGICAL PROTECTION 2014; 34:279-96. [PMID: 24704989 DOI: 10.1088/0952-4746/34/2/279] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
This paper's goal is to assess secondary neutron doses received by paediatric patients treated for intracranial tumours using a 178 MeV proton beam. The MCNPX Monte Carlo model of the proton therapy facility, previously validated through experimental measurements for both proton and neutron dosimetry, was used. First, absorbed dose was calculated for organs located outside the clinical target volume using a series of hybrid computational phantoms for different ages and considering a realistic treatment plan. In general, secondary neutron dose was found to decrease as the distance to the treatment field increases and as the patient age increases. In addition, secondary neutron doses were studied as a function of the beam incidence. Next, neutron equivalent dose was assessed using organ-specific energy-dependent radiation weighting factors determined from Monte Carlo simulations of neutron spectra at each organ. The equivalent dose was found to reach a maximum value of ∼155 mSv at the level of the breasts for a delivery of 49 proton Gy to an intracranial tumour of a one-year-old female patient. Finally, a thorough comparison of the calculation results with published data demonstrated the dependence of neutron dose on the treatment configuration and proved the need for facility-specific and treatment-dependent neutron dose calculations.
Collapse
Affiliation(s)
- R Sayah
- Institut de Radioprotection et de Sûreté Nucléaire (IRSN)-PRP-HOM/SDE-BP17, F-92262 Fontenay-aux-Roses Cedex, France
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
10
|
Farah J, Martinetti F, Sayah R, Lacoste V, Donadille L, Trompier F, Nauraye C, Marzi LD, Vabre I, Delacroix S, Hérault J, Clairand I. Monte Carlo modeling of proton therapy installations: a global experimental method to validate secondary neutron dose calculations. Phys Med Biol 2014; 59:2747-65. [DOI: 10.1088/0031-9155/59/11/2747] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
11
|
Islam MR, Collums TL, Zheng Y, Monson J, Benton ER. Off-axis dose equivalent due to secondary neutrons from uniform scanning proton beams during proton radiotherapy. Phys Med Biol 2013; 58:8235-51. [DOI: 10.1088/0031-9155/58/22/8235] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
|
12
|
Newhauser WD, Rechner L, Mirkovic D, Yepes P, Koch NC, Titt U, Fontenot JD, Zhang R. Benchmark measurements and simulations of dose perturbations due to metallic spheres in proton beams. RADIAT MEAS 2013; 58:37-44. [PMID: 25147474 PMCID: PMC4136527 DOI: 10.1016/j.radmeas.2013.08.001] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Abstract
Monte Carlo simulations are increasingly used for dose calculations in proton therapy due to its inherent accuracy. However, dosimetric deviations have been found using Monte Carlo code when high density materials are present in the proton beam line. The purpose of this work was to quantify the magnitude of dose perturbation caused by metal objects. We did this by comparing measurements and Monte Carlo predictions of dose perturbations caused by the presence of small metal spheres in several clinical proton therapy beams as functions of proton beam range, spread-out Bragg peak width and drift space. Monte Carlo codes MCNPX, GEANT4 and Fast Dose Calculator (FDC) were used. Generally good agreement was found between measurements and Monte Carlo predictions, with the average difference within 5% and maximum difference within 17%. The modification of multiple Coulomb scattering model in MCNPX code yielded improvement in accuracy and provided the best overall agreement with measurements. Our results confirmed that Monte Carlo codes are well suited for predicting multiple Coulomb scattering in proton therapy beams when short drift spaces are involved.
Collapse
Affiliation(s)
- Wayne D. Newhauser
- The University of Texas M. D. Anderson Cancer Center, 1515 Holcombe Boulevard, Unit 94, Houston, Texas 77030, USA
- The University of Texas Graduate School of Biomedical Sciences at Houston, 6767 Bertner, Houston, TX 77030, USA
- Department of Medical Physics, Mary Bird Perkins Cancer Center, Baton Rouge, LA, 70809, USA
| | - Laura Rechner
- The University of Texas M. D. Anderson Cancer Center, 1515 Holcombe Boulevard, Unit 94, Houston, Texas 77030, USA
- The University of Texas Graduate School of Biomedical Sciences at Houston, 6767 Bertner, Houston, TX 77030, USA
| | - Dragan Mirkovic
- The University of Texas M. D. Anderson Cancer Center, 1515 Holcombe Boulevard, Unit 94, Houston, Texas 77030, USA
- The University of Texas Graduate School of Biomedical Sciences at Houston, 6767 Bertner, Houston, TX 77030, USA
| | - Pablo Yepes
- Department of Physics and Astronomy, MS 315, Rice University, 6100 Main Street, Houston, TX 77005, USA
| | - Nicholas C. Koch
- Department of Radiation Oncology, Medical University of South Carolina, 169 Ashley Avenue, Charleston, SC, 29425, USA
| | - Uwe Titt
- The University of Texas M. D. Anderson Cancer Center, 1515 Holcombe Boulevard, Unit 94, Houston, Texas 77030, USA
- The University of Texas Graduate School of Biomedical Sciences at Houston, 6767 Bertner, Houston, TX 77030, USA
| | - Jonas D. Fontenot
- Department of Medical Physics, Mary Bird Perkins Cancer Center, Baton Rouge, LA, 70809, USA
| | - Rui Zhang
- Department of Medical Physics, Mary Bird Perkins Cancer Center, Baton Rouge, LA, 70809, USA
| |
Collapse
|
13
|
Kim DW, Chung WK, Shin J, Lim YK, Shin D, Lee SB, Yoon M, Park SY, Shin DO, Cho JK. Secondary neutron dose measurement for proton eye treatment using an eye snout with a borated neutron absorber. Radiat Oncol 2013; 8:182. [PMID: 23866307 PMCID: PMC3723544 DOI: 10.1186/1748-717x-8-182] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2013] [Accepted: 07/15/2013] [Indexed: 11/30/2022] Open
Abstract
Background We measured and assessed ways to reduce the secondary neutron dose from a system for proton eye treatment. Methods Proton beams of 60.30 MeV were delivered through an eye-treatment snout in passive scattering mode. Allyl diglycol carbonate (CR-39) etch detectors were used to measure the neutron dose in the external field at 0.00, 1.64, and 6.00 cm depths in a water phantom. Secondary neutron doses were measured and compared between those with and without a high-hydrogen–boron-containing block. In addition, the neutron energy and vertices distribution were obtained by using a Geant4 Monte Carlo simulation. Results The ratio of the maximum neutron dose equivalent to the proton absorbed dose (H(10)/D) at 2.00 cm from the beam field edge was 8.79 ± 1.28 mSv/Gy. The ratio of the neutron dose equivalent to the proton absorbed dose with and without a high hydrogen-boron containing block was 0.63 ± 0.06 to 1.15 ± 0.13 mSv/Gy at 2.00 cm from the edge of the field at depths of 0.00, 1.64, and 6.00 cm. Conclusions We found that the out-of-field secondary neutron dose in proton eye treatment with an eye snout is relatively small, and it can be further reduced by installing a borated neutron absorbing material.
Collapse
Affiliation(s)
- Dong Wook Kim
- Department of Radiation Oncology, Kyung Hee University Hospital at Gandong, Seoul, Korea
| | | | | | | | | | | | | | | | | | | |
Collapse
|
14
|
Carnicer A, Letellier V, Rucka G, Angellier G, Sauerwein W, Hérault J. Study of the secondary neutral radiation in proton therapy: Toward an indirectin vivodosimetry. Med Phys 2012; 39:7303-16. [DOI: 10.1118/1.4765049] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
15
|
Zheng Y, Liu Y, Zeidan O, Schreuder AN, Keole S. Measurements of neutron dose equivalent for a proton therapy center using uniform scanning proton beams. Med Phys 2012; 39:3484-92. [PMID: 22755728 DOI: 10.1118/1.4718685] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE Neutron exposure is of concern in proton therapy, and varies with beam delivery technique, nozzle design, and treatment conditions. Uniform scanning is an emerging treatment technique in proton therapy, but neutron exposure for this technique has not been fully studied. The purpose of this study is to investigate the neutron dose equivalent per therapeutic dose, H/D, under various treatment conditions for uniform scanning beams employed at our proton therapy center. METHODS Using a wide energy neutron dose equivalent detector (SWENDI-II, ThermoScientific, MA), the authors measured H/D at 50 cm lateral to the isocenter as a function of proton range, modulation width, beam scanning area, collimated field size, and snout position. They also studied the influence of other factors on neutron dose equivalent, such as aperture material, the presence of a compensator, and measurement locations. They measured H/D for various treatment sites using patient-specific treatment parameters. Finally, they compared H/D values for various beam delivery techniques at various facilities under similar conditions. RESULTS H/D increased rapidly with proton range and modulation width, varying from about 0.2 mSv/Gy for a 5 cm range and 2 cm modulation width beam to 2.7 mSv/Gy for a 30 cm range and 30 cm modulation width beam when 18 × 18 cm(2) uniform scanning beams were used. H/D increased linearly with the beam scanning area, and decreased slowly with aperture size and snout retraction. The presence of a compensator reduced the H/D slightly compared with that without a compensator present. Aperture material and compensator material also have an influence on neutron dose equivalent, but the influence is relatively small. H/D varied from about 0.5 mSv/Gy for a brain tumor treatment to about 3.5 mSv/Gy for a pelvic case. CONCLUSIONS This study presents H/D as a function of various treatment parameters for uniform scanning proton beams. For similar treatment conditions, the H/D value per uncollimated beam size for uniform scanning beams was slightly lower than that from a passive scattering beam and higher than that from a pencil beam scanning beam, within a factor of 2. Minimizing beam scanning area could effectively reduce neutron dose equivalent for uniform scanning beams, down to the level close to pencil beam scanning.
Collapse
Affiliation(s)
- Yuanshui Zheng
- ProCure Proton Therapy Center, 5901 West Memorial Road, Oklahoma City, OK 73142, USA.
| | | | | | | | | |
Collapse
|
16
|
|
17
|
Kim S, Min BJ, Yoon M, Kim J, Shin DH, Lee SB, Park SY, Cho S, Kim DH. Secondary radiation doses of intensity-modulated radiotherapy and proton beam therapy in patients with lung and liver cancer. Radiother Oncol 2011; 98:335-9. [DOI: 10.1016/j.radonc.2011.01.018] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2010] [Revised: 01/18/2011] [Accepted: 01/25/2011] [Indexed: 11/15/2022]
|
18
|
Secondary doses delivered to an anthropomorphic male phantom under prostate irradiation with proton and carbon ion beams. RADIAT MEAS 2010. [DOI: 10.1016/j.radmeas.2010.05.020] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|
19
|
Sawakuchi GO, Mirkovic D, Perles LA, Sahoo N, Zhu XR, Ciangaru G, Suzuki K, Gillin MT, Mohan R, Titt U. An MCNPX Monte Carlo model of a discrete spot scanning proton beam therapy nozzle. Med Phys 2010; 37:4960-70. [PMID: 20964215 DOI: 10.1118/1.3476458] [Citation(s) in RCA: 46] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE The purposes of this study were to validate a discrete spot scanning proton beam nozzle using the Monte Carlo (MC) code MCNPX and use the MC validated model to investigate the effects of a low-dose envelope, which surrounds the beam's central axis, on measurements of integral depth dose (IDD) profiles. METHODS An accurate model of the discrete spot scanning beam nozzle from The University of Texas M. D. Anderson Cancer Center (Houston, Texas) was developed on the basis of blueprints provided by the manufacturer of the nozzle. The authors performed simulations of single proton pencil beams of various energies using the standard multiple Coulomb scattering (MCS) algorithm within the MCNPX source code and a new MCS algorithm, which was implemented in the MCNPX source code. The MC models were validated by comparing calculated in-air and in-water lateral profiles and percentage depth dose profiles for single pencil beams with their corresponding measured values. The models were then further tested by comparing the calculated and measured three-dimensional (3-D) dose distributions. Finally, an IDD profile was calculated with different scoring radii to determine the limitations on the use of commercially available plane-parallel ionization chambers to measure IDD. RESULTS The distance to agreement, defined as the distance between the nearest positions of two equivalent distributions with the same value of dose, between measured and simulated ranges was within 0.13 cm for both MCS algorithms. For low and intermediate pencil beam energies, the MC simulations using the standard MCS algorithm were in better agreement with measurements. Conversely, the new MCS algorithm produced better results for high-energy single pencil beams. The IDD profile calculated with cylindrical tallies with an area equivalent to the area of the largest commercially available ionization chamber showed up to 7.8% underestimation of the integral dose in certain depths of the IDD profile. CONCLUSIONS The authors conclude that a combination of MCS algorithms is required to accurately reproduce experimental data of single pencil beams and 3-D dose distributions for the scanning beam nozzle. In addition, the MC simulations showed that because of the low-dose envelope, ionization chambers with radii as large as 4.08 cm are insufficient to accurately measure IDD profiles for a 221.8 MeV pencil beam in the scanning beam nozzle.
Collapse
Affiliation(s)
- Gabriel O Sawakuchi
- Department of Physics, Carleton University, 1125 Colonel By Drive, Ottawa, Ontario K1S 5B6, Canada.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
20
|
Hultqvist M, Gudowska I. Secondary absorbed doses from light ion irradiation in anthropomorphic phantoms representing an adult male and a 10 year old child. Phys Med Biol 2010; 55:6633-53. [DOI: 10.1088/0031-9155/55/22/004] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
21
|
Radiation-Induced Cancers From Modern Radiotherapy Techniques: Intensity-Modulated Radiotherapy Versus Proton Therapy. Int J Radiat Oncol Biol Phys 2010; 77:1477-85. [DOI: 10.1016/j.ijrobp.2009.07.011] [Citation(s) in RCA: 77] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2009] [Revised: 07/03/2009] [Accepted: 07/03/2009] [Indexed: 11/19/2022]
|
22
|
Wissmann F, Giesen U, Klages T, Schardt D, Martino G, Sunil C. Microdosimetric measurements in the secondary radiation field produced in (12)C-therapy irradiations. RADIATION AND ENVIRONMENTAL BIOPHYSICS 2010; 49:331-336. [PMID: 20340029 DOI: 10.1007/s00411-010-0279-z] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/15/2009] [Accepted: 03/06/2010] [Indexed: 05/29/2023]
Abstract
The ambient dose equivalent from the secondary radiation produced during irradiation of a cylindrical water phantom with 200 MeV/u (12)C-ions was investigated at the biophysics cave at GSI Helmholtzzentrum für Schwerionenforschung in Darmstadt, Germany. Pencil-like ion beams were delivered by the heavy-ion synchrotron SIS18 using the slow extraction mode. Since the secondary radiation field outside the phantom is complex in its particle composition and particle energy distribution, microdosimetric methods developed for the dosimetry of the cosmic radiation field at flight altitudes, which is similar in terms of complexity, were applied. Lineal energy distributions and the ambient dose equivalent were measured with a tissue-equivalent proportional counter at different particle emission angles. An additional veto counter allowed the identification of the different contributions of charged and neutral particles. A significant increase in the mean quality factor was observed at large emission angles which could be attributed to the decreasing contributions of charged particles compared to the (relative) contributions from neutrons.
Collapse
Affiliation(s)
- F Wissmann
- Physikalisch-Technische Bundesanstalt, Bundesallee 100, 38116 Braunschweig, Germany,
| | | | | | | | | | | |
Collapse
|
23
|
Dowdell S, Clasie B, Wroe A, Guatelli S, Metcalfe P, Schulte R, Rosenfeld A. Tissue equivalency of phantom materials for neutron dosimetry in proton therapy. Med Phys 2010; 36:5412-9. [PMID: 20095253 DOI: 10.1118/1.3250857] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE Previous Monte Carlo and experimental studies involving secondary neutrons in proton therapy have employed a number of phantom materials that are designed to represent human tissue. In this study, the authors determined the suitability of common phantom materials for dosimetry of secondary neutrons, specifically for pediatric and intracranial proton therapy treatments. METHODS This was achieved through comparison of the absorbed dose and dose equivalent from neutrons generated within the phantom materials and various ICRP tissues. The phantom materials chosen for comparison were Lucite, liquid water, solid water, and A150 tissue equivalent plastic, These phantom materials were compared to brain, muscle, and adipose tissues. RESULTS The magnitude of the doses observed were smaller than those reported in previous experimental and Monte Carlo studies, which incorporated neutrons generated in the treatment head. The results show that for both neutron absorbed dose and dose equivalent, no single phantom material gives agreement with tissue within 5% at all the points considered. Solid water gave the smallest mean variation with the tissues out of field where neutrons are the primary contributor to the total dose. CONCLUSIONS Of the phantom materials considered, solid water shows best agreement with tissues out of field.
Collapse
Affiliation(s)
- Stephen Dowdell
- Centre for Medical Radiation Physics, University of Wollongong, Wollongong, New South Wales 2522, Australia.
| | | | | | | | | | | | | |
Collapse
|
24
|
Zheng Y, Newhauser W, Klein E, Low D. Monte Carlo simulation of the neutron spectral fluence and dose equivalent for use in shielding a proton therapy vault. Phys Med Biol 2009; 54:6943-57. [PMID: 19887713 DOI: 10.1088/0031-9155/54/22/013] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Neutron production is of principal concern when designing proton therapy vault shielding. Conventionally, neutron calculations are based on analytical methods, which do not accurately consider beam shaping components and nozzle shielding. The goal of this study was to calculate, using Monte Carlo modeling, the neutron spectral fluence and neutron dose equivalent generated by a realistic proton therapy nozzle and evaluate how these data could be used in shielding calculations. We modeled a contemporary passive scattering proton therapy nozzle in detail with the MCNPX simulation code. The neutron spectral fluence and dose equivalent at various locations in the treatment room were calculated and compared to those obtained from a thick iron target bombarded by parallel proton beams, the simplified geometry on which analytical methods are based. The neutron spectral fluence distributions were similar for both methods, with deeply penetrating high-energy neutrons (E > 10 MeV) being most prevalent along the beam central axis, and low-energy neutrons predominating the neutron spectral fluence in the lateral region. However, unlike the inverse square falloff used in conventional analytical methods, this study shows that the neutron dose equivalent per therapeutic dose in the treatment room decreased with distance approximately following a power law, with an exponent of about -1.63 in the lateral region and -1.73 in the downstream region. Based on the simulated data according to the detailed nozzle modeling, we developed an empirical equation to estimate the neutron dose equivalent at any location and distance in the treatment vault, e.g. for cases in which detailed Monte Carlo modeling is not feasible. We applied the simulated neutron spectral fluence and dose equivalent to a shielding calculation as an example.
Collapse
Affiliation(s)
- Yuanshui Zheng
- Department of Radiation Oncology, Washington University School of Medicine, Campus Box 8224, 4921 Parkview Place, St Louis, MO 63110, USA.
| | | | | | | |
Collapse
|
25
|
Shin D, Yoon M, Kwak J, Shin J, Lee SB, Park SY, Park S, Kim DY, Cho KH. Secondary neutron doses for several beam configurations for proton therapy. Int J Radiat Oncol Biol Phys 2009; 74:260-5. [PMID: 19362245 DOI: 10.1016/j.ijrobp.2008.10.090] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2008] [Revised: 09/26/2008] [Accepted: 10/10/2008] [Indexed: 10/20/2022]
Abstract
PURPOSE To compare possible neutron doses produced in scanning and scattering modes, with the latter assessed using a newly built passive-scattering proton beam line. METHODS AND MATERIALS A 40 x 30.5 x 30-cm water phantom was irradiated with 230-MeV proton beams using a gantry angle of 270 degrees , a 10-cm-diameter snout, and a brass aperture with a diameter of 7 cm and a thickness of 6.5 cm. The secondary neutron doses during irradiation were measured at various points using CR-39 detectors, and these measurements were cross-checked using a neutron survey meter with a 22-cm range and a 5-cm spread-out Bragg peak. RESULTS The maximum doses due to secondary neutrons produced by a scattering beam-delivery system were on the order of 0.152 mSv/Gy and 1.17 mSv/Gy at 50 cm from the beam isocenter in the longitudinal (0 degrees ) and perpendicular (90 degrees ) directions, respectively. The neutron dose equivalent to the proton absorbed dose, measured from 10 cm to 100 cm from the isocenter, ranged from 0.071 mSv/Gy to 1.96 mSv/Gy in the direction of the beam line (i.e., phi = 0 degrees ). The largest neutron dose, of 3.88 mSv/Gy, was observed at 135 degrees and 25 cm from the isocenter. CONCLUSIONS Although the secondary neutron doses in proton therapy were higher when a scattering mode rather than a scanning mode was used, they did not exceed the scattered photon dose in typical photon treatments.
Collapse
Affiliation(s)
- Dongho Shin
- Proton Therapy Center, National Cancer Center, Goyang, Korea
| | | | | | | | | | | | | | | | | |
Collapse
|
26
|
Newhauser WD, Fontenot JD, Mahajan A, Kornguth D, Stovall M, Zheng Y, Taddei PJ, Mirkovic D, Mohan R, Cox JD, Woo S. The risk of developing a second cancer after receiving craniospinal proton irradiation. Phys Med Biol 2009; 54:2277-91. [PMID: 19305036 DOI: 10.1088/0031-9155/54/8/002] [Citation(s) in RCA: 144] [Impact Index Per Article: 9.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
The purpose of this work was to compare the risk of developing a second cancer after craniospinal irradiation using photon versus proton radiotherapy by means of simulation studies designed to account for the effects of neutron exposures. Craniospinal irradiation of a male phantom was calculated for passively-scattered and scanned-beam proton treatment units. Organ doses were estimated from treatment plans; for the proton treatments, the amount of stray radiation was calculated separately using the Monte Carlo method. The organ doses were converted to risk of cancer incidence using a standard formalism developed for radiation protection purposes. The total lifetime risk of second cancer due exclusively to stray radiation was 1.5% for the passively scattered treatment versus 0.8% for the scanned proton beam treatment. Taking into account the therapeutic and stray radiation fields, the risk of second cancer from intensity-modulated radiation therapy and conventional radiotherapy photon treatments were 7 and 12 times higher than the risk associated with scanned-beam proton therapy, respectively, and 6 and 11 times higher than with passively scattered proton therapy, respectively. Simulations revealed that both passively scattered and scanned-beam proton therapies confer significantly lower risks of second cancers than 6 MV conventional and intensity-modulated photon therapies.
Collapse
Affiliation(s)
- Wayne D Newhauser
- Department of Radiation Physics, The University of Texas M D Anderson Cancer Center, 1515 Holcombe Blvd, Houston, TX, 77030, USA.
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
27
|
Taddei PJ, Mirkovic D, Fontenot JD, Giebeler A, Zheng Y, Kornguth D, Mohan R, Newhauser WD. Stray radiation dose and second cancer risk for a pediatric patient receiving craniospinal irradiation with proton beams. Phys Med Biol 2009; 54:2259-75. [PMID: 19305045 DOI: 10.1088/0031-9155/54/8/001] [Citation(s) in RCA: 87] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Proton beam radiotherapy unavoidably exposes healthy tissue to stray radiation emanating from the treatment unit and secondary radiation produced within the patient. These exposures provide no known benefit and may increase a patient's risk of developing a radiogenic cancer. The aims of this study were to calculate doses to major organs and tissues and to estimate second cancer risk from stray radiation following craniospinal irradiation (CSI) with proton therapy. This was accomplished using detailed Monte Carlo simulations of a passive-scattering proton treatment unit and a voxelized phantom to represent the patient. Equivalent doses, effective dose and corresponding risk for developing a fatal second cancer were calculated for a 10-year-old boy who received proton therapy. The proton treatment comprised CSI at 30.6 Gy plus a boost of 23.4 Gy to the clinical target volume. The predicted effective dose from stray radiation was 418 mSv, of which 344 mSv was from neutrons originating outside the patient; the remaining 74 mSv was caused by neutrons originating within the patient. This effective dose corresponds to an attributable lifetime risk of a fatal second cancer of 3.4%. The equivalent doses that predominated the effective dose from stray radiation were in the lungs, stomach and colon. These results establish a baseline estimate of the stray radiation dose and corresponding risk for a pediatric patient undergoing proton CSI and support the suitability of passively-scattered proton beams for the treatment of central nervous system tumors in pediatric patients.
Collapse
Affiliation(s)
- Phillip J Taddei
- The University of Texas M D Anderson Cancer Center, 1515 Holcombe Blvd, Unit 94, Houston, TX 77030, USA
| | | | | | | | | | | | | | | |
Collapse
|
28
|
Taddei PJ, Krishnan S, Mirkovic D, Yepes P, Newhauser WD. Effective Dose from Stray Radiation for a Patient Receiving Proton Therapy for Liver Cancer. AIP CONFERENCE PROCEEDINGS 2009; 1099:445-449. [PMID: 20865142 PMCID: PMC2943390 DOI: 10.1063/1.3120070] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Abstract
Because of its advantageous depth-dose relationship, proton radiotherapy is an emerging treatment modality for patients with liver cancer. Although the proton dose distribution conforms to the target, healthy tissues throughout the body receive low doses of stray radiation, particularly neutrons that originate in the treatment unit or in the patient. The aim of this study was to calculate the effective dose from stray radiation and estimate the corresponding risk of second cancer fatality for a patient receiving proton beam therapy for liver cancer. Effective dose from stray radiation was calculated using detailed Monte Carlo simulations of a double-scattering proton therapy treatment unit and a voxelized human phantom. The treatment plan and phantom were based on CT images of an actual adult patient diagnosed with primary hepatocellular carcinoma. For a prescribed dose of 60 Gy to the clinical target volume, the effective dose from stray radiation was 370 mSv; 61% of this dose was from neutrons originating outside of the patient while the remaining 39% was from neutrons originating within the patient. The excess lifetime risk of fatal second cancer corresponding to the total effective dose from stray radiation was 1.2%. The results of this study establish a baseline estimate of the stray radiation dose and corresponding risk for an adult patient undergoing proton radiotherapy for liver cancer and provide new evidence to corroborate the suitability of proton beam therapy for the treatment of liver tumors.
Collapse
Affiliation(s)
- Phillip J Taddei
- The University of Texas M. D. Anderson Cancer Center, 1515 Holcombe Blvd., Unit 94, Houston, TX 77030, USA
| | - Sunil Krishnan
- The University of Texas M. D. Anderson Cancer Center, 1515 Holcombe Blvd., Unit 94, Houston, TX 77030, USA
| | - Dragan Mirkovic
- The University of Texas M. D. Anderson Cancer Center, 1515 Holcombe Blvd., Unit 94, Houston, TX 77030, USA
| | - Pablo Yepes
- Rice University, 6100 Main Street, MS 315, Houston, TX 77005, USA
| | - Wayne D Newhauser
- The University of Texas M. D. Anderson Cancer Center, 1515 Holcombe Blvd., Unit 94, Houston, TX 77030, USA
| |
Collapse
|
29
|
Titt U, Sahoo N, Ding X, Zheng Y, Newhauser WD, Zhu XR, Polf JC, Gillin MT, Mohan R. Assessment of the accuracy of an MCNPX-based Monte Carlo simulation model for predicting three-dimensional absorbed dose distributions. Phys Med Biol 2008; 53:4455-70. [PMID: 18670050 DOI: 10.1088/0031-9155/53/16/016] [Citation(s) in RCA: 52] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
In recent years, the Monte Carlo method has been used in a large number of research studies in radiation therapy. For applications such as treatment planning, it is essential to validate the dosimetric accuracy of the Monte Carlo simulations in heterogeneous media. The AAPM Report no 105 addresses issues concerning clinical implementation of Monte Carlo based treatment planning for photon and electron beams, however for proton-therapy planning, such guidance is not yet available. Here we present the results of our validation of the Monte Carlo model of the double scattering system used at our Proton Therapy Center in Houston. In this study, we compared Monte Carlo simulated depth doses and lateral profiles to measured data for a magnitude of beam parameters. We varied simulated proton energies and widths of the spread-out Bragg peaks, and compared them to measurements obtained during the commissioning phase of the Proton Therapy Center in Houston. Of 191 simulated data sets, 189 agreed with measured data sets to within 3% of the maximum dose difference and within 3 mm of the maximum range or penumbra size difference. The two simulated data sets that did not agree with the measured data sets were in the distal falloff of the measured dose distribution, where large dose gradients potentially produce large differences on the basis of minute changes in the beam steering. Hence, the Monte Carlo models of medium- and large-size double scattering proton-therapy nozzles were valid for proton beams in the 100 MeV-250 MeV interval.
Collapse
Affiliation(s)
- U Titt
- The University of Texas M D Anderson Cancer Center, 1515 Holcombe Blvd., Houston, TX 77030, USA
| | | | | | | | | | | | | | | | | |
Collapse
|
30
|
Taddei PJ, Fontenot JD, Zheng Y, Mirkovic D, Lee AK, Titt U, Newhauser WD. Reducing stray radiation dose to patients receiving passively scattered proton radiotherapy for prostate cancer. Phys Med Biol 2008; 53:2131-47. [PMID: 18369278 PMCID: PMC4144020 DOI: 10.1088/0031-9155/53/8/009] [Citation(s) in RCA: 50] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Proton beam radiotherapy exposes healthy tissue to stray radiation emanating from the treatment unit and secondary radiation produced within the patient. These exposures provide no known benefit and may increase a patient's risk of developing a radiogenic second cancer. The aim of this study was to explore strategies to reduce stray radiation dose to a patient receiving a 76 Gy proton beam treatment for cancer of the prostate. The whole-body effective dose from stray radiation, E, was estimated using detailed Monte Carlo simulations of a passively scattered proton treatment unit and an anthropomorphic phantom. The predicted value of E was 567 mSv, of which 320 mSv was attributed to leakage from the treatment unit; the remainder arose from scattered radiation that originated within the patient. Modest modifications of the treatment unit reduced E by 212 mSv. Surprisingly, E from a modified passive-scattering device was only slightly higher (109 mSv) than from a nozzle with no leakage, e.g., that which may be approached with a spot-scanning technique. These results add to the body of evidence supporting the suitability of passively scattered proton beams for the treatment of prostate cancer, confirm that the effective dose from stray radiation was not excessive, and, importantly, show that it can be substantially reduced by modest enhancements to the treatment unit.
Collapse
Affiliation(s)
- Phillip J Taddei
- The University of Texas M. D. Anderson Cancer Center, 1515 Holcombe Blvd., Unit 94, Houston, TX 77030, USA
| | - Jonas D Fontenot
- The University of Texas M. D. Anderson Cancer Center, 1515 Holcombe Blvd., Unit 94, Houston, TX 77030, USA
| | - Yuanshui Zheng
- The University of Texas M. D. Anderson Cancer Center, 1515 Holcombe Blvd., Unit 94, Houston, TX 77030, USA
| | - Dragan Mirkovic
- The University of Texas M. D. Anderson Cancer Center, 1515 Holcombe Blvd., Unit 94, Houston, TX 77030, USA
| | - Andrew K Lee
- The University of Texas M. D. Anderson Cancer Center, 1515 Holcombe Blvd., Unit 94, Houston, TX 77030, USA
| | - Uwe Titt
- The University of Texas M. D. Anderson Cancer Center, 1515 Holcombe Blvd., Unit 94, Houston, TX 77030, USA
| | - Wayne D Newhauser
- The University of Texas M. D. Anderson Cancer Center, 1515 Holcombe Blvd., Unit 94, Houston, TX 77030, USA
| |
Collapse
|
31
|
Moyers MF, Benton ER, Ghebremedhin A, Coutrakon G. Leakage and scatter radiation from a double scattering based proton beamline. Med Phys 2008; 35:128-44. [PMID: 18293570 DOI: 10.1118/1.2805086] [Citation(s) in RCA: 55] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
Proton beams offer several advantages over conventional radiation techniques for treating cancer and other diseases. These advantages might be negated if the leakage and scatter radiation from the beamline and patient are too large. Although the leakage and scatter radiation for the double scattering proton beamlines at the Loma Linda University Proton Treatment Facility were measured during the acceptance testing that occurred in the early 1990s, recent discussions in the radiotherapy community have prompted a reinvestigation of this contribution to the dose equivalent a patient receives. The dose and dose equivalent delivered to a large phantom patient outside a primary proton field were determined using five methods: simulations using Monte Carlo calculations, measurements with silver halide film, measurements with ionization chambers, measurements with rem meters, and measurements with CR-39 plastic nuclear track detectors. The Monte Carlo dose distribution was calculated in a coronal plane through the simulated patient that coincided with the central axis of the beam. Measurements with the ionization chambers, rem meters, and plastic nuclear track detectors were made at multiple locations within the same coronal plane. Measurements with the film were done in a plane perpendicular to the central axis of the beam and coincident with the surface of the phantom patient. In general, agreement between the five methods was good, but there were some differences. Measurements and simulations also tended to be in agreement with the original acceptance testing measurements and results from similar facilities published in the literature. Simulations illustrated that most of the neutrons entering the patient are produced in the final patient-specific aperture and precollimator just upstream of the aperture, not in the scattering system. These new results confirm that the dose equivalents received by patients outside the primary proton field from primary particles that leak through the nozzle are below the accepted standards for x-ray and electron beams. The total dose equivalent outside of the field is similar to that received by patients undergoing treatments with intensity modulated x-ray therapy. At the center of a patient for a whole course of treatment, the dose equivalent is comparable to that delivered by a single whole-body XCT scan.
Collapse
Affiliation(s)
- M F Moyers
- Proton Therapy, Inc., Colton, California 92324, USA.
| | | | | | | |
Collapse
|
32
|
Brenner DJ, Hall EJ. Secondary neutrons in clinical proton radiotherapy: a charged issue. Radiother Oncol 2008; 86:165-70. [PMID: 18192046 DOI: 10.1016/j.radonc.2007.12.003] [Citation(s) in RCA: 110] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2007] [Revised: 12/07/2007] [Accepted: 12/07/2007] [Indexed: 10/22/2022]
Abstract
Hospital-based proton facilities may represent a major advance in radiation therapy, in part because of excellent dose distributions around the tumor, and in part because of the potentially lower whole-body dose compared with photon radiotherapy. Most current proton beams are spread out to cover the tumor using beam scattering and collimation techniques (passive scattering); this will necessarily result in an extra whole-body neutron dose, due to interactions of the protons with the scattering and collimating beam elements. However, the clinical significance of this whole-body low-dose neutron exposure has remained controversial. The number of proton facilities worldwide is increasing rapidly, and most of these facilities are/will be based on passive scattering. Thus it is important to assess and, ideally, minimize, the potential for second cancer induction by secondary neutrons. We discuss here the neutron doses involved, and the associated potential second cancer risks, with an emphasis on the uncertainties involved.
Collapse
Affiliation(s)
- David J Brenner
- Center for Radiological Research, Columbia University Medical Center, NY 10032, USA.
| | | |
Collapse
|
33
|
Zheng Y, Fontenot J, Taddei P, Mirkovic D, Newhauser W. Monte Carlo simulations of neutron spectral fluence, radiation weighting factor and ambient dose equivalent for a passively scattered proton therapy unit. Phys Med Biol 2007; 53:187-201. [PMID: 18182696 DOI: 10.1088/0031-9155/53/1/013] [Citation(s) in RCA: 57] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Stray neutron exposures pose a potential risk for the development of secondary cancer in patients receiving proton therapy. However, the behavior of the ambient dose equivalent is not fully understood, including dependences on neutron spectral fluence, radiation weighting factor and proton treatment beam characteristics. The objective of this work, therefore, was to estimate neutron exposures resulting from the use of a passively scattered proton treatment unit. In particular, we studied the characteristics of the neutron spectral fluence, radiation weighting factor and ambient dose equivalent with Monte Carlo simulations. The neutron spectral fluence contained two pronounced peaks, one a low-energy peak with a mode around 1 MeV and one a high-energy peak that ranged from about 10 MeV up to the proton energy. The mean radiation weighting factors varied only slightly, from 8.8 to 10.3, with proton energy and location for a closed-aperture configuration. For unmodulated proton beams stopped in a closed aperture, the ambient dose equivalent from neutrons per therapeutic absorbed dose (H*(10)/D) calculated free-in-air ranged from about 0.3 mSv/Gy for a small scattered field of 100 MeV proton energy to 19 mSv/Gy for a large scattered field of 250 MeV proton energy, revealing strong dependences on proton energy and field size. Comparisons of in-air calculations with in-phantom calculations indicated that the in-air method yielded a conservative estimation of stray neutron radiation exposure for a prostate cancer patient.
Collapse
Affiliation(s)
- Yuanshui Zheng
- Department of Radiation Physics, Unit 94, The University of Texas M. D. Anderson Cancer Center, 1515 Holcombe Blvd., Houston, TX 77030, USA
| | | | | | | | | |
Collapse
|
34
|
Polf JC, Harvey MC, Titt U, Newhauser WD, Smith AR. Initial beam size study for passive scatter proton therapy. I. Monte Carlo verification. Med Phys 2007; 34:4213-8. [DOI: 10.1118/1.2789497] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
35
|
Newhauser W, Fontenot J, Zheng Y, Polf J, Titt U, Koch N, Zhang X, Mohan R. Monte Carlo simulations for configuring and testing an analytical proton dose-calculation algorithm. Phys Med Biol 2007; 52:4569-84. [PMID: 17634651 DOI: 10.1088/0031-9155/52/15/014] [Citation(s) in RCA: 78] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
Contemporary treatment planning systems for proton radiotherapy typically use analytical pencil-beam algorithms - which require a comprehensive set of configuration data - to predict the absorbed dose distributions in the patient. In order to reduce the time required to prepare a new proton treatment planning system for clinical use, it was desirable to configure the planning system before measured beam data were available. However, it was not known if the Monte Carlo simulation method was a practical alternative to measuring beam profiles. The purpose of this study was to develop a model of a passively scattered proton therapy unit, to simulate the properties of the proton fields using the Monte Carlo technique and to configure an analytical treatment planning system using the simulated beam data. Additional simulations and treatment plans were calculated in order to validate the pencil-beam predictions against the Monte Carlo simulations using realistic treatment beams. Comparison of dose distributions in a water phantom revealed small dose difference and distances to agreement under the validation conditions. The total simulation time for generating the 768 beam configuration profiles was approximately 6 weeks using 30 nodes in a parallel processing cluster. The results of this study show that it is possible to configure and test a proton treatment planning system prior to the availability of measured proton beam data. The model presented here provided a means to reduce by several months the time required to prepare an analytical treatment planning system for patient treatments.
Collapse
Affiliation(s)
- Wayne Newhauser
- Department of Radiation Physics, The University of Texas M. D. Anderson Cancer Center, Houston, Texas, USA.
| | | | | | | | | | | | | | | |
Collapse
|
36
|
Zheng Y, Newhauser W, Fontenot J, Taddei P, Mohan R. Monte Carlo study of neutron dose equivalent during passive scattering proton therapy. Phys Med Biol 2007; 52:4481-96. [PMID: 17634645 DOI: 10.1088/0031-9155/52/15/008] [Citation(s) in RCA: 98] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Stray radiation exposures are of concern for patients receiving proton radiotherapy and vary strongly with several treatment factors. The purposes of this study were to conservatively estimate neutron exposures for a contemporary passive scattering proton therapy system and to understand how they vary with treatment factors. We studied the neutron dose equivalent per therapeutic absorbed dose (H/D) as a function of treatment factors including proton energy, location in the treatment room, treatment field size, spread-out Bragg peak (SOBP) width and snout position using both Monte Carlo simulations and analytical modeling. The H/D value at the isocenter for a 250 MeV medium field size option was estimated to be 20 mSv Gy(-1). H/D values generally increased with the energy or penetration range, fell off sharply with distance from the treatment unit, decreased modestly with the aperture size, increased with the SOBP width and decreased with the snout distance from the isocenter. The H/D values from Monte Carlo simulations agreed well with experimental results from the literature. The analytical model predicted H/D values within 28% of those obtained in simulations; this value is within typical neutron measurement uncertainties.
Collapse
Affiliation(s)
- Yuanshui Zheng
- The University of Texas M. D. Anderson Cancer Center, 1515 Holcombe Blvd, Houston, TX 77030, USA.
| | | | | | | | | |
Collapse
|
37
|
Newhauser WD, Koch NC, Fontenot JD, Rosenthal SJ, S Gombos D, Fitzek MM, Mohan R. Dosimetric impact of tantalum markers used in the treatment of uveal melanoma with proton beam therapy. Phys Med Biol 2007; 52:3979-90. [PMID: 17664589 DOI: 10.1088/0031-9155/52/13/021] [Citation(s) in RCA: 55] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Metallic fiducial markers are frequently implanted in patients prior to external-beam radiation therapy to facilitate tumor localization. There is little information in the literature, however, about the perturbations in proton absorbed-dose distribution these objects cause. The aim of this study was to assess the dosimetric impact of perturbations caused by 2.5 mm diameter by 0.2 mm thick tantalum fiducial markers when used in proton therapy for treating uveal melanoma. Absorbed dose perturbations were measured using radiochromic film and confirmed by Monte Carlo simulations of the experiment. Additional Monte Carlo simulations were performed to study the effects of range modulation and fiducial placement location on the magnitude of the dose shadow for a representative uveal melanoma treatment. The simulations revealed that the fiducials caused perturbations in the absorbed-dose distribution, including absorbed-dose shadows of 22% to 82% in a typical proton beam for treating uveal melanoma, depending on the marker depth and orientation. The clinical implication of this study is that implanted fiducials may, in certain circumstances, cause dose shadows that could lower the tumor dose and theoretically compromise local tumor control. To avoid this situation, fiducials should be positioned laterally or distally with respect to the target volume.
Collapse
Affiliation(s)
- Wayne D Newhauser
- The University of Texas M D Anderson Cancer Center, 1515 Holcombe Boulevard, Unit 94, Houston, TX 77030, USA.
| | | | | | | | | | | | | |
Collapse
|
38
|
Fan J, Luo W, Fourkal E, Lin T, Li J, Veltchev I, Ma CM. Shielding design for a laser-accelerated proton therapy system. Phys Med Biol 2007; 52:3913-30. [PMID: 17664585 DOI: 10.1088/0031-9155/52/13/017] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
In this paper, we present the shielding analysis to determine the necessary neutron and photon shielding for a laser-accelerated proton therapy system. Laser-accelerated protons coming out of a solid high-density target have broad energy and angular spectra leading to dose distributions that cannot be directly used for therapeutic applications. A special particle selection and collimation device is needed to generate desired proton beams for energy- and intensity-modulated proton therapy. A great number of unwanted protons and even more electrons as a side-product of laser acceleration have to be stopped by collimation devices and shielding walls, posing a challenge in radiation shielding. Parameters of primary particles resulting from the laser-target interaction have been investigated by particle-in-cell simulations, which predicted energy spectra with 300 MeV maximum energy for protons and 270 MeV for electrons at a laser intensity of 2 x 10(21) W cm(-2). Monte Carlo simulations using FLUKA have been performed to design the collimators and shielding walls inside the treatment gantry, which consist of stainless steel, tungsten, polyethylene and lead. A composite primary collimator was designed to effectively reduce high-energy neutron production since their highly penetrating nature makes shielding very difficult. The necessary shielding for the treatment gantry was carefully studied to meet the criteria of head leakage <0.1% of therapeutic absorbed dose. A layer of polyethylene enclosing the whole particle selection and collimation device was used to shield neutrons and an outer layer of lead was used to reduce photon dose from neutron capture and electron bremsstrahlung. It is shown that the two-layer shielding design with 10-12 cm thick polyethylene and 4 cm thick lead can effectively absorb the unwanted particles to meet the shielding requirements.
Collapse
Affiliation(s)
- J Fan
- Department of Radiation Oncology, Fox Chase Cancer Center, Philadelphia, PA 19111, USA
| | | | | | | | | | | | | |
Collapse
|
39
|
|
40
|
Mourtada F, Koch N, Newhauser W. 106Ru/106Rh plaque and proton radiotherapy for ocular melanoma: a comparative dosimetric study. RADIATION PROTECTION DOSIMETRY 2005; 116:454-60. [PMID: 16604677 DOI: 10.1093/rpd/nci266] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/08/2023]
Abstract
The objective of this study was to perform comparative dosimetric studies of both 106Ru/106Rh plaque brachytherapy and external beam proton therapy proposed for ocular treatments at the University of Texas M. D. Anderson Cancer Center, Houston, TX, USA. These modalities were also compared with traditional 125I plaque brachytherapy. Using a standardised eye model with a representative ocular melanoma tumour, the relative dose distributions within the tumour and surrounding tissue were calculated using the Monte Carlo code MCNPX. Published absorbed dose distributions benchmarked the Monte Carlo models. Results indicate that the proton beam provided superior dose uniformity within the tumour volume, whereas the dose distribution from 106Ru/106Rh was more heterogeneous. Relative to 125I COMS plaque, both 106Ru/106Rh and protons have shown more confined dose distributions to the tumour volume in this situation, thus sparing other critical ocular structures. For protons, it has been shown that only doses lower than the maximum dose are delivered outside the tumour volume. Depending on the clinical situation, this may aid in the sparing of critical structures located in the sclera and optic disc boundary. The Monte Carlo model's statistical uncertainties of the mean dose estimates for the 106Ru/106Rh plaque and proton beam were 3 and 2.5%, respectively.
Collapse
Affiliation(s)
- F Mourtada
- Radiation Physics Department, Box 94, The University of Texas M. D. Anderson Cancer Center, 1515 Holcombe Blvd, Houston, TX 77030, USA.
| | | | | |
Collapse
|